-1- INSTALLATION INSTRUCTIONS No. 59-1935-1 MULTI DIMENSIONAL OUTDOOR DETECTOR MULTI DIMENSIONAL OUTDOOR DETECTOR VX Infinity TM series VX Infinity TM series FEATURES CONTENTS VXI-ST Standard model with 2 PIR WIRED MODEL VXI-AM VXI-ST with anti-masking VXI-DAM VXI-AM with micro-wave The VX Infinity TM series provide highly reliable detection functions, reducing false reports or report losses. The VX Infinity TM series deliver stable detection performance even in severe outdoor environments. - 12 m (40 ft.) by 90 degree flexible detection pattern adjustable to 5 ranges - SMDA Logic for advanced temperature compensation and environmental noise immunity. - Easy Masking for over spill prevention - Double Conductive Shielding against bright light disturbance. - Conduit/TX-Battery Case for both wired and wireless-ready models. BASIC FEATURES - Active IR Anti-Masking for detecting covering objects - Tough Mod Dual Technology based on OPTEX gold-plated microwave module OPTIONAL FEATURES INTRODUCTION 1-1 BEFORE INSTALLATION 1-2 PARTS IDENTIFICATION 1-3 DETECTION AREA INSTALLATION 2-1 BEFORE MOUNTING 2-2 WALL TAMPER WRS-02 (OPTION) 2-3 MOUNTING 2-4 MOUNTING WITHOUT BACK BOX 2-5 MOUNTING WITH BACK BOX 2-6 WIRING 2-7 PLUG-IN END OF LINE RESISTORS (EOL) (OPTION) 2-8 AREA ANGLE ADJUSTMENT 1 2 2 3 4 4 4 5 5 6 7 7 8 8 9 10 12 13 14 14 15 3 4 5 6 7 2-9 AREA MASKING 2-10 DETECTION LENGTH ADJUSTMENT SWITCH SETTING WALK TEST LED INDICATION SPECIFICATIONS 6-1 SPECIFICATIONS 6-2 DIMENSIONS SETTING OF SPECIAL DETECTION AREA

Upload: doanquynh

Post on 25-Jun-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

-1-

INSTALLATION INSTRUCTIONSNo. 59-1935-1

MULTI DIMENSIONAL OUTDOOR DETECTORMULTI DIMENSIONAL OUTDOOR DETECTOR

VX InfinityTM seriesVX InfinityTM series

FEATURES

CONTENTS

VXI-ST Standard model with 2 PIR

WIRED MODEL

VXI-AM VXI-ST with anti-masking

VXI-DAM VXI-AM with micro-wave

The VX InfinityTM series provide highly reliable detection functions, reducing false reports or report losses. The VX InfinityTM series deliver stable detection performance even in severe outdoor environments.

- 12 m (40 ft.) by 90 degree flexible detection pattern adjustable to 5 ranges - SMDA Logic for advanced temperature compensation and environmental noise immunity.- Easy Masking for over spill prevention - Double Conductive Shielding against bright light disturbance. - Conduit/TX-Battery Case for both wired and wireless-ready models.

BASIC FEATURES

- Active IR Anti-Masking for detecting covering objects - Tough Mod Dual Technology based on OPTEX gold-plated microwave module

OPTIONAL FEATURES

INTRODUCTION 1-1 BEFORE INSTALLATION1-2 PARTS IDENTIFICATION1-3 DETECTION AREAINSTALLATION2-1 BEFORE MOUNTING2-2 WALL TAMPER WRS-02 (OPTION)2-3 MOUNTING2-4 MOUNTING WITHOUT BACK BOX2-5 MOUNTING WITH BACK BOX2-6 WIRING2-7 PLUG-IN END OF LINE RESISTORS (EOL) (OPTION)2-8 AREA ANGLE ADJUSTMENT

1

2

234

44556778

89

101213

141415

3456

7

2-9 AREA MASKING2-10 DETECTION LENGTH ADJUSTMENTSWITCH SETTINGWALK TESTLED INDICATIONSPECIFICATIONS6-1 SPECIFICATIONS6-2 DIMENSIONSSETTING OF SPECIAL DETECTION AREA

-2-

Warning

INTRODUCTION11-1 BEFORE INSTALLATION

Warning

Caution

Failure to follow the instructions provided with this indication and improper handling may cause death or serious injury.

Failure to follow the instructions provided with this indication and improper handling may cause injury and/or property damage.

The check mark indicates recommendation.

The nix sign indicates prohibition.

• Sunlight and reflection • Heat source • Objects moving in the wind

0.8 – 1.2 m(2.64 – 3.94 ft)

Parallel

Tilt

Do not remove the PCB. Keep product away from direct splash.

Mounting height. Keep the detector parallel to the ground.

Consider the direction a person is approaching from, as well as the detection area.

Install the detector in a place where it is free from false alarm factors. For example:

-3-

Cover unit

Main unit

Back box

Back box cap

Wiring sponge

Mounting plate

1-2 PARTS IDENTIFICATION

-Precautions for installing two or more sensors

Masking seal × 3 pcsFor wall mountingScrew kit

Screw (4 × 20 mm)

Optional accessories

Wall tamper (WRS-02) PLUG-IN EOL (PEU)

1.0 m (3.28 ft) or more Less than 1.0 m (3.28 ft)

Do not install two or more VXI-DAMs in side by side or face to face. Doing so may cause malfunction. VXI-DAM may be installed in back to back. If mounting on the same wall, make sure that each unit is at least 1.0 m (3.28 ft) apart from the other.

VXI-STVXI-AM

VXI-DAM

-4-

a

b

c

d

ef

g hi

j

l

m

n

k

INSTALLATION2

1-3 DETECTION AREA

2-1 BEFORE MOUNTING

Control panelWall tamper (option)WRS-02

Twist and swage the wires.

TOP VIEW

SIDE VIEWLength limiting position 1 (Default)

PIR

MW

Area diagram of horizontal position D

12m

12m 10m 12m10m5m 5m0

10m

5m

0

DA B C E F G

WRS-02 (option)

1m

0 5m 10m 12m

Length limiting position 2

1m

0 5m 10m 12m

Length limiting position 3

1m

0 5m 10m 12m

Length limiting position 4

1m

0 5m 10m 12m

Length limiting position 5

1m

0 5m 10m 12m

Note>>The maximum detection length may vary asshown below due to environment conditions.

Remove the cap.1 Open the cover unit.2 Remove the main unit from the back box.

3 Remove the back box from the mounting plate.

4

Mount the wall tamper (WRS-02) on the back of the main unit.

1 Run the wire along the wiring groove.

2 Install the unit on the terminal block and control panel.

3

Store the connecting cable in a trench and seal with a label already in place.

2-2 WALL TAMPER WRS-02 (OPTION)

-5-

2-3 MOUNTINGMount the mounting plate.

2-4 MOUNTING WITHOUT BACK BOXThe unit is installed without a back box unless the main unit requires a protrusion off the mounting wall.

Mount the main unit on the mounting plate.

Wall mount Pole mount

Electric gang box mount Conduit installation

Metal band

* Use a metal band with 25 mm or less in width.

Pitch 83.5 mm (3.29 inch)

An electric gang box can be connected. Open the knockout located at the bottom of the back box.

Connect the pipe and back box.

When mounting to electric gang box (single), follow wall mount instructions.

Wiring hole

Wiring holeWiring hole

Wiring sponge

Note>>Pay attention to warterproof.

Note>>It is optional to use the Backbox in hardwired models.

ø 21 mm

2-6Proceed to

-6-

2-5 MOUNTING WITH BACK BOXWhen a certain distance from the mounting surface is required for purposes such as avoiding an unwanted object, use the back box to install the unit.

Open a wiring knockout on the back box and pass the wire from the mounting plate.

Wiring

Put the top of the back box on the hook.

Wiring hole

Wiring sponge

Wiring sponge

1.

2.

3.

Wiring hole

1 Open a wiring knockout inside the back box.

2 Mount a back box on the mounting plate.

3 Mount the main unit on the back box. 4 Put the cap on top.

-7-

2-6 WIRING

-Power cable length

The power cable should be limited to the following length.

Wiring terminal is located on the upper part of the main box.

-When setting the resistance value using PLUG-IN EOL

Three types of signals - ALARM, TROUBLE, and TAMPER - can be recognized through the combination of the resistance value and wires for the TR, COM, and TP terminals.

-When setting the resistance value withoutusing PLUG-IN EOLWire resistors between the appropriate terminals as follows:

This feature may be used when connecting VXI to a control panel that supports the EOL technique.

Terminals<VXI-ST>

Pow

er (+

)P

ower

(-)

Spa

reS

pare

Ala

rmA

larm

Tam

per

Tam

per

Aux

. inp

utA

ux. i

nput

<VXI-AM> <VXI-DAM>

Pow

er (+

)P

ower

(-)

Spa

reTr

oubl

eC

omm

onA

larm

Tam

per

Tam

per

Aux

. inp

utA

ux. i

nput

WIRE GAUGE

AWG22(0.33mm2)

290 m(950 ft)

620 m(2,030 ft)

240 m(790 ft)

520 m(1,710 ft)

160 m(520 ft)

360 m(1,180 ft)

12 V

VXI-ST VXI-AM VXI-DAMCurrent draw 20 mA Current draw 24 mA Current draw 35 mA

14 V 12 V 14 V 12 V 14 V

450 m(1,480 ft)

980 m(3,220 ft)

380 m(1,250 ft)

820 m(2,690 ft)

260 m(850 ft)

560 m(1,840 ft)

720 m(2,360 ft)

1,570 m(5,150 ft)

600 m(1,970 ft)

1,310 m(4,300 ft)

410 m(1,350 ft)

900 m(2,950 ft)

AWG20(0.52mm2)

AWG18(0.83mm2)

COMMONTROUBLE

ALARMTAMPER

TypeInsert direction

A

Caution>>For details, refer to a note provided with plugs. Make sure to apply thecorrect type of plug according to the system

+ - SP TR COM AL TP TP

Triple-EOL

Double-EOL

TAMPERALARMTROUBLEPLUG-IN EOL

CONTROL PANEL

+ - SP TR COM AL TP TP

TAMPERALARMTROUBLE

2-7 PLUG-IN END OF LINE RESISTORS (EOL) (OPTION)

-8-

2-8 AREA ANGLE ADJUSTMENT

2-9 AREA MASKING

Note>>When creating a special detection area, refer to the end of this manual.

If there is an unwanted object within the detection area, apply an area masking label to the appropriate area.

Insert the protruding part of the cover into the lens hole.

Fit the edge of the lens.

Slide the lens holder to secure it.

Horizontal position D (Default)

Horizontal position B (F: symmetrical position)

Horizontal position C (E: symmetrical position)

Horizontal position A (G: symmetrical position)

DA B C E F G DA B C E F G

DA B C E F GDA B C E F G

DA B C E F G

DA B C E F GDA B C E F G

or

oror

Unwantedobject (Tree)

1 Slide the lens holder and remove the lens holder out of the cover as shown below.

2 Identify positions to mask on the lens and apply a corresponding strip from the masking sheet 1.

3 Insert the lens into the cover. 4 Mount the lens holder to the cover.

The angle can be adjusted in 7 levels from A to G.

The detection area becomes 14 zones only when A or G is selected.

-9-

2-10 DETECTION LENGTH ADJUSTMENT

Both upper and lower detection area are blocked

IMPORTANTBOTH DETECTION AREAS MUST BE

BLOCKED FOR DETECTION

Detection!

NODetection

NODetection

Only upper detection area is blocked

Only lower detection area is blocked

MW sensitivity adjustment knob

1 Adjust the PIR detection length by sliding the lower PIR to the desired position.

2 Adjust the MW detection length by rotating the MW sensitivity adjustment according to the PIR area.

Detection length setting chart

* The detection lengths described above should be used as a guideline.

Position

1(Factorydefault)

2

3

4

5

12.0 m(40.0 ft)

8.5 m(27.9 ft)

6.0 m(19.7 ft)

3.5 m(11.5 ft)

2.5 m(8.2 ft)

10.0 -17.0 m(32.1 - 55.8 ft)

7.0 - 12.0 m(23.0 - 39.4 ft)

5.0 - 8.5 m(16.4 - 27.9 ft)

3.0 - 6.0 m(9.8 - 19.7 ft)

2.0 - 3.5 m(6.6 - 11.5 ft)

Max detection length Detection areaMW

sensitivityadjustment

12 m

8.5 m

6 m

3.5 m

2.5 m

-10-

DIP switch1 LED2 ALARM OUTPUT3 AUX INPUT4 ANTI-MASKING5 MICROWAVE IMMUNITY

SWITCH SETTING3

1

ON

24

53

ON1

23

45

DIP switch 1

OFF ⇔ ON

-LEDVXI-STVXI-AM

VXI-DAM

POSITION FUNCTION

ON(Factory default)

OFF

LED ON

LED OFF

DIP switch 2

N.C. ⇔ N.O.

-ALARM OUTPUTVXI-STVXI-AM

VXI-DAM

ON1

23

45

POSITION FUNCTION

N.O.

N.C.(Factory default)

N.O. output

N.C. output

VXI features can be set on/off by DIP switch settings.

MW sensitivity adjustment

PIR sensitivity selector

-11-

DIP switch 3

AND ⇔ OR

-AUX INPUTVXI-STVXI-AM

VXI-DAM

ON1

23

45

POSITION FUNCTION

OR

AND(Factory default)

When either the main unit or the secondary detect someone,the alarm is activated.

When both the main unit and the secondary detect someone,the alarm is activated. Choose the setting when a secondaryunit is not connected.

DIP switch 4

OFF ⇔ ON

-ANTI-MASKINGVXI-STVXI-AM

VXI-DAM

ON1

23

45

POSITION FUNCTION

OFF

ON(Factory default) ANTI-MASKING ON

By connecting a secondary unit (another warning sensor), you can extend the detection area and correct false alarms. The secondary unit must have a voltage free N.C. output such as another PIR detector or AIR detector.<Infrared (AIR) sensors, thermal line (PIR) sensors, magnet switches, etc.>

ANTI-MASKING OFF

When masking condition continues more than 3 minutes, TROUBLE will be generated.TROUBLE is generated after 20 seconds under the anti-masking test mode.

Teaching mode starts when both the separate box cover and the main unit cover are attached.Please be careful not to leave any object within 1 m from the unit.

<ANTI-MASKING function>

ANTI-MASKING test modeThe trouble is output after 20 seconds.

Normal modeThe trouble is output after 3 minutes.

10 minutes1 minute

Teaching

Note>>The alarm is activated only if both the main unit and the socondary unit is activatedwithin 60 sec.

In OR mode, a secondary detector must be fitted. If not fitted, the unit will generatean alarm continuously.

-12-

DIP switch 5

STD ⇔ IMMUNITY

-MICROWAVE IMMUNITYVXI-STVXI-AM

VXI-DAM

ON1

23

45

POSITION FUNCTION

IMMUNITY

STD(Factory default)

MICROWAVE IMMUNITY logic is activated. Use this under harsh environment (e.g. vegetation sway).

MICROWAVE IMMUNITY logic is not activated.

PIR SENSITIVITY SELECTOR-PIR SENSITIVITYVXI-STVXI-AM

VXI-DAM

POSITION FUNCTION

HIGH

MIDDLE(Factory default)

High sensitivity

LOW Low sensitivity

Middle sensitivity

HIGH

MIDDLE

LOW

WALK TEST4

Check that the cover is completely closed.

ON1

23

45

ON1

23

45

Note>>The switch is set to “ON” by factory default.

Note>>For the walk test, make a motion at a distance more than1.0 m (3.28 ft) away from the detecter.

Detected Not detected

1 Set the DIP switch 1 (LED) to “ON”. 2 Attach the main unit cover.

3 Check that LED lights for 2 seconds when the intended object is detected.

4 If the LED does not need to be turned on at all times, set the DIP switch 1 (LED) to “OFF”.

-13-

LED INDICATION 5

REDYELLOW

(VXI-DAM only)Blink Light OFF

<VXI-ST> <VXI-AM>

<VXI-DAM>

Detector condition LED indicator

Warm-up

Blinks for approx. 60 seconds.

AlarmLights for 2 seconds.

Masking detection(VXI-AM only)

Blinks 3 times and then repeats.

Note>>The LED blinks even if the DIP switch 1 (LED) is set to “OFF”.

Detector condition LED indicator

Warm-up

Blinks for approx. 60 seconds.

AlarmRED LED lights for 2 seconds.

MW detectionYELLOW LED lights for 2 seconds.

Masking detection

Blinks 3 times and then repeats.

Note>>The LED blinks even if the DIP switch 1 (LED) is set to “OFF”.

RED YELLOW

-14-

SPECIFICATIONS 66-1 SPECIFICATIONS

VXI-DAMVXI-AMVXI-STModel

Passive infrared & MicrowavePassive infraredDetection method

12.0 m (40 ft) 90° wide / 16 zonesPIR Coverage

12 – 2.5 m (5 levels)PIR distance limit

0.3 – 1.5 m/s (0.98 – 4.92 ft/s)Detectable speed

2.0°C (3.6°F) at 0.6 m/sSensitivity

9.5 – 18 V DCPower input

Current draw 20 mA (max.)at 12 V DC

24 mA (max.)at 12 V DC

35 mA (max)at 12 V DC

2.0 ±1 sec.Alarm period

Approx. 60 sec. (LED blinks)Warm-up period

N.C. / N.O. Selectable 28 V DC 0.1 A (max)

N.C. 28 V DC 0.1 A (max)

Alarm output

N.C. 28 V DC 0.1 A (max) open when cover removed.Tamper output

Trouble output

LED indicator Red: Warm-up, alarm, masking detection (VXI-AM only) Red: Warm-up, alarm, masking detection.Yellow: Warm-up, MW detect.

No alarm 10 V/mRF interference

-30 – +60°C (-22 – +140°F) -20 – +60°C (-4 – +140°F)Operating temperature

95% max.Environment humidity

IP55International protection

Wall, Pole (Outdoor, Indoor)Mounting

0.8 – 1.2 m (2.64 – 3.94 ft)Mounting height

500 g (17.7 oz.)Weight 600 g (21.2 oz.)

Accessories Screw (4×20 mm) ×2 , Wiring sponge ×3 , Masking seal ×3

*Specifications and designs are subject to change without prior notice.

6-2 DIMENSIONS

Unit: mm (inch)

-

Pitch=83.5(3.29)

70.9 (2.80)

181.9(7.16)

64.5 (2.54)

71.3 (2.81)

105.5 (4.15)

185.9(7.32)

-15-

SETTING OF SPECIAL DETECTION AREA7Using masking seals 2 to 6, you can set a special detection area for the horizontal position A or G.

Masking seal 2

Masking seal 4

Masking seal 6

Masking seal 3

Masking seal 5

Area can be set only at the both sides.

Five patterns of special detection areas can be configured by applying a masking sticker.

1.5 × 10 m area can be set.

10 × 1.5 m area can be set.

5 × 10 m area can be set.

10 × 5 m area can be set.

Set to the desired area setting direction (horizontal position A or G).

When setting other than masking seal 1, cut off the knockout portion at the lower lens holder.

Select a masking seal from 2 to 6 according to the desired shape of area setting, and put it on the lens.

a

b

c

d

ef

g hi

j

k

l

m

n a

b

c

d

ef

g hi

j

k

l

m

n

a

b

c

d

ef

g hi

j

k

l

m

n

a

b

c

d

ef

g hi

j

k

l

m

n a

b

c

d

ef

g hi

j

k

l

m

n

12 m 12 m

12 m

10 m 10 m

10 m

5 m 5 m

5 m

12 m 12 m

12 m

10 m 10 m

10 m

5 m 5 m

5 m

12 m 12 m

12 m

10 m 10 m

10 m

5 m 5 m

5 m

12 m 12 m

12 m

10 m 10 m

10 m

5 m 5 m

5 m

12 m 12 m

12 m

10 m 10 m

10 m

5 m 5 m

5 m

Position G Position A

Position G Position A

Position G Position APosition G Position A

Position G Position A

Set to A or G

The lower detection area adjustment position must be “position 1” (12m) as default.

-16-

OPTEX INCORPORATED (USA)TEL:+1-909-993-5770Tech:(800)966-7839 URL:http://www.optexamerica.com/

OPTEX KOREA CO., LTD. (KOREA)TEL:+82-2-719-5971URL:http://www.optexkorea.com/

OPTEX SECURITY Sp.z o.o. (POLAND)TEL:+48-22-598-06-55URL:http://www.optex.com.pl/

OPTEX (DONGGUAN) CO., LTD.SHANGHAI OFFICE (CHINA)TEL:+86-21-34600673URL:http://www.optexchina.com/

OPTEX CO., LTD. (JAPAN)(ISO 9001 Certified)(ISO 14001 Certified)5-8-12 Ogoto OtsuShiga 520-0101JAPANTEL:+81-77-579-8670FAX:+81-77-579-8190URL:http://www.optex.co.jp/e/

OPTEX (EUROPE) LTD. (UK)TEL:+44-1628-631000URL:http://www.optex-europe.com/

OPTEX SECURITY SAS (FRANCE)TEL:+33-437-55-50-50URL:http://www.optex-security.com/

FCC ID : DC9 OPMW IC : 4012A-OPMWThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

The VXI series is only a part of a complete system, therefore we cannot accept complete responsibility for any damages or other consequences resulting from an intrusion.

NOTE

The following statement will be provided with the equipment as required by Article 6.3 of the R&TTE Directive, 1999/5/EC.

The Optex VXI series are in conformity with all essential requirements of the R&TTE Directive (1999/5/EC). This equipment has been assessed to the following standards:EN 300 440-1: 2009EN 50130-4: 2004 including amendment 2: 2003EN 60950-1: 2006+A11: 2009

This product is marked with which signifies conformity with Class II product requirements specified in the R&TTE Directive.

The following table indicates countries and their appropiate microwave (MW) frequency. Do not use VXI-DAM/RDAM when the frequency does not meet the local requirement. For countries not included in this list, please consult the responsible Spectrum Management Agency.

Country of intended use AppropriateMW frequency

AppropriateMW frequencyCountry of intended use

Austria 9.900GHz Luxembourg 10.525GHzBelgium 10.525GHz The Netherlands 10.525GHzDenmark 10.525GHz Spain 10.525GHzFinland 9.900GHz Sweden 10.525GHzFrance 9.900GHz United Kingdom 10.587GHzGreece 10.525GHz Other non-EU: Iceland 10.525GHzIreland 10.587GHz Norway 10.525GHzItaly 10.525GHz Switzerland 9.900GHz

Note>>These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion. These products confirm to the EMC Directive 2004/108/EC.

COMPLIANCE• VXI series complies with following Directives / Standards.

Directive: EMC Directive 2004/108/ECApplied Standards: EN 50130-4: 1995 +A1: 1998 +A2: 2003

EN 55022: 2006

• VXI-RDAM also complies with following Directives / Standardsmarked Class II, Directive: R&TTE Directive 1999/5/ECApplied Standards: EN 300 440-1: 2009

EN 300 440-2: 2009EN 301 489-1: 2008EN 301 489-3: 2002EN 50371: 2002EN 60950-1: 2006 +A11: 2009

The following table indicates the areas of intended use of the equipment and any known restrictions. For countries not included in this list, please consult the responsible Spectrum Management Agency.

FCC ID: DC9 OPMWWL IC: 4012A-OPMWWLThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference.(2) This device must accept any interference received, including

interference that may cause undesired operation.

Country of intended useAustriaBelgiumDenmarkFinlandFranceGreeceIrelandItaly

LuxembourgThe NetherlandsSpainSwedenUnited KingdomOther non-EU: IcelandNorwaySwitzerland

13.700GHz10.525GHz10.525GHz13.700GHz10.587GHz10.525GHz10.587GHz10.525GHz

10.525GHz10.525GHz10.525GHz10.525GHz10.587GHz10.525GHz10.525GHz10,525GHz

Restrictions Country of intended use Restrictions

0700