multi-function double clamp digital phase angle metergf211b multi-function double clamp digital...

3
GF211B Multi-function Double Clamp Digital Phase Angle Meter GF211B mul-funcon double clamp digital phase angle meter is a mul-funconal portable instrument. It is an ideal choice for electric power bureau, factories, mine, petroleum-chemistry enterprises, metallurgy factories and so on. Features 1. Can check connecon of transformer 2. Measure two way voltage phase sequence 3. Discern inducve circuit and capacive circuit 4. Can check whether the meter connecon is right or not 5. Can evaluate the running speed of electric kWh meter 6. Directly read differenal protecon phase among every unit of CT 7. Hhigh resoluon of current, so can be used as a leakage current meter 8. Current signal is obtained by the clamp current transformer on line directly 9. Measure phase angle between two voltages, between two current or between voltage and current 10. Measure alternang voltage (U), alternang current (I), frequency (F), acve power (P), reacve power (Q), power factor (PF) and so on Parameters GF211B PHASE ANGLE METER WWW.GFUVE.COM Phase Angle Meter | EDITION : 14-02 | Page 1 of 3 Subject to change without notice Electrical parameters Accuracy cl a ss 0.5% Powe r supply 3.7V ba e rie s Scale Pha s e 0-360° AC Volta ge 0-500V AC Current 200mA / 2A / 10A Fre quency 45-65Hz Acve powe r accuracy 0.5%, re s oluon 0.01W Powe r f actor -1 ~ 0 ~ 1, re s oluon 0.001 Fundamental error (under standard operang environment) Te mpe ra ture 23°C±5°C Moi sture < 65%

Upload: others

Post on 13-Aug-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Multi-function Double Clamp Digital Phase Angle MeterGF211B multi-function double clamp digital phase angle meter is a multi-functional portable instrument. It is an ideal choice for

GF211BMulti-function Double Clamp Digital Phase Angle Meter

GF211B multi-function double clamp digital phase angle meter is a multi-functional portable instrument. It is an ideal choice for electric power bureau, factories, mine, petroleum-chemistry enterprises, metallurgy factories and so on.

Features 1. Can check connection of transformer2. Measure two way voltage phase sequence3. Discern inductive circuit and capacitive circuit4. Can check whether the meter connection is right or not5. Can evaluate the running speed of electric kWh meter6. Directly read differential protection phase among every unit of CT7. Hhigh resolution of current, so can be used as a leakage current meter8. Current signal is obtained by the clamp current transformer on line directly9. Measure phase angle between two voltages, between two current or between voltage and current10. Measure alternating voltage (U), alternating current (I), frequency (F), active power (P), reactive power (Q), power factor (PF) and so on

Parameters

GF211BPHASE ANGLE METER

WWW.GFUVE.COM Phase Angle Meter | EDITION : 14-02 | Page 1 of 3

Subject to change without notice

Electrical parametersAccuracy class 0.5%Power supply 3.7V batteriesScalePhase 0-360°AC Voltage 0-500VAC Current 200mA / 2A / 10AFrequency 45-65HzActive power accuracy 0.5%, resolution 0.01WPower factor -1 ~ 0 ~ 1, resolution 0.001Fundamental error (under standard operating environment)Temperature 23°C±5°CMoisture < 65%

Page 2: Multi-function Double Clamp Digital Phase Angle MeterGF211B multi-function double clamp digital phase angle meter is a multi-functional portable instrument. It is an ideal choice for

Electrical parameters - continued

Wave form Sine wave Distortion ≤ 1% Frequency 50±2Hz, 60±2HzWire position Center of clampPhase measurement Voltage: 100V±25V

Current: 1A±0.2APhase accuracy 1.0% FSVoltage accuracy200V 1.0FS, Resolution 0.1V500V 1.0FS, Resolution 1VCurrent accuracy10A 1.0FS, Resolution 10mA2A 1.0FS, Resolution 1mA200mA 1.0FS, Resolution 0.1mAInput impedanceWhen measure voltage 1MΩInput voltage impedance > 120KΩ when measure phasePhase measurementVoltage range 2-500VCurrent range 0.005-10AAdditional errorMeasure phase angle, the voltage and the current Less than the fundamental errorMeasure current The error led by wires away from center of clamps is less

than the fundamental errorSafety specification Resistance to voltage The meter can resist 1000V (AC sine wave, 50Hz or 60 Hz)

for 1 minute between the meter circuit and the metercase; Between input joint U1 and U2 can resist 500V (ACsine wave, 50Hz or 60 Hz) for 1 minute.

Insulation resistance The resistance both between the meter circuit and themeter surface and between the terminals U1 and U2 isgreater than 100MΩ.

Mechanical parametersDimensions (W×D×H) (mm) 185×85×41Weight (kg) 0.26

Environmental conditionsWorking temperature 0°C±40°CHumidity ≤ 80%

Fundamental error (under standard operating environment) - continued

WWW.GFUVE.COM Phase Angle Meter | EDITION : 14-02 | Page 2 of 3

Subject to change without notice

GF211BPHASE ANGLE METER

Page 3: Multi-function Double Clamp Digital Phase Angle MeterGF211B multi-function double clamp digital phase angle meter is a multi-functional portable instrument. It is an ideal choice for

WWW.GFUVE.COM Phase Angle Meter | EDITION : 14-02 | Page 3 of 3

Subject to change without notice

AccessoryMulti-function double clamp digital phase angle meter 1Clamps 10A 2Clamp wire 2Voltage wire 2User's manual 1Certification of quality 1Box 1

GF211BPHASE ANGLE METER