music from biosignals semisi finau. ongoing project (2011) 2 software, 1 electronic my part is...
TRANSCRIPT
![Page 1: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/1.jpg)
Music from Biosignals
Semisi Finau
![Page 2: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/2.jpg)
Ongoing project (2011) 2 software, 1 electronic My part is new
Design a system that utilise electromyogram (EMG) signals to make music
Introduction
![Page 3: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/3.jpg)
Project Overview
Wireless
Microcontroller
Computer Speaker
![Page 4: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/4.jpg)
Bio-signals
EEG ECG
EMG
![Page 5: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/5.jpg)
Characteristics
![Page 6: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/6.jpg)
Engineering matrix
Weight
Needle Wire surface
safety 3
Cost 1
Reliability 3
Easy to use 3
Time & effort
3
Rank 3 2 1
Electrode Decision Matrix
![Page 7: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/7.jpg)
Decision Matrix electrodeEngineer Matrix
Weight Gelled (wet) Dry
Safety 3
Cost 1
Easy to use 3
Readily available 3
Reliable 3
Relative rank 2 1
![Page 8: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/8.jpg)
Electrode design circuit
Yu M. Chi and Gert CauwenberghsUniversity of California, San Diego
![Page 9: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/9.jpg)
Electrode Design
![Page 10: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/10.jpg)
Electrode assembling
![Page 11: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/11.jpg)
Electrodes Assembly
![Page 12: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/12.jpg)
Complete electrode
![Page 13: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/13.jpg)
Electrodes Testing
![Page 14: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/14.jpg)
Electrodes Testing
![Page 15: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/15.jpg)
Electrodes Testing
![Page 16: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/16.jpg)
Engineer matrix
Weight Arduino Picaxe
Cost 2 $14 $26.84
ADC 2 10 bits 10 bits
speed 2 16 MHz 4-16 MHz
RAM 2 32 Kb 128-1280 bytes
Analog input 2 6 6
Language 2 C++ & C Basic language
Microcontroller Decision Matrix
![Page 17: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/17.jpg)
Data Processing
![Page 18: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/18.jpg)
Wireless
Bluetooth
![Page 19: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/19.jpg)
Execution plan Task How long Completion date
Complete processing of data (Arduino Uno)
2 weeks 10th Oct, 2014
Wirelessly transmitting of the data (Bluetooth)
1 week 17th Oct, 2014
Completion of the project
1 week 24th Oct, 2014
![Page 20: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/20.jpg)
*Goal- To make music out of biosignals *Universal design project
Conclusion
![Page 21: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/21.jpg)
Questions???
People are like Music some speak the truth and others
are just noise.
![Page 22: Music from Biosignals Semisi Finau. Ongoing project (2011) 2 software, 1 electronic My part is new Design a system that utilise electromyogram](https://reader036.vdocuments.net/reader036/viewer/2022062518/56649e8a5503460f94b8ef5c/html5/thumbnails/22.jpg)
Kenneth Pope Damian Kleiss Craig Peacock Craig Dawson
Acknowledgement