mvi56e mnet mnetxt user manual

181
MVI56E-MNET / MNETXT ControlLogix Platform Modbus TCP/IP Interface Module April 23, 2014 USER MANUAL

Upload: wagnerp

Post on 17-Aug-2015

253 views

Category:

Documents


2 download

DESCRIPTION

Prosoft MNETXT

TRANSCRIPT

MVI56E-MNET / MNETXT ControlLogix Platform Modbus TCP/IP Interface Module April 23, 2014USER MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products. If you have suggestions, comments, compliments or complaints about our products, documentation, or support, please write or call us. How to Contact Us ProSoft Technology 5201 Truxtun Ave., 3rd Floor Bakersfield, CA 93309 +1 (661) 716-5100 +1 (661) 716-5101 (Fax) www.prosoft-technology.com [email protected] Copyright 2014 ProSoft Technology, Inc., All rights reserved. MVI56E-MNET / MNETXT User Manual April 23, 2014 ProSoft Technology , ProLinx , inRAx , ProTalk , and RadioLinx are Registered Trademarks of ProSoft Technology, Inc. All other brand or product names are or may be trademarks of, and are used to identify products and services of, their respective owners. ProSoft Technology Product Documentation In an effort to conserve paper, ProSoft Technology no longer includes printed manuals with our product shipments. User Manuals, Datasheets, Sample Ladder Files, and Configuration Files are provided on the enclosed DVD, and are available at no charge from our web site: www.prosoft-technology.com Warnings North America Warnings AWarning - Explosion Hazard - Substitution of components may impair suitability for Class I, Division 2. BWarning - Explosion Hazard - When in Hazardous Locations, turn off power before replacing or rewiring modules. CWarning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is known to be nonhazardous. DSuitable for use in Class I, Division 2 Groups A, B, C, and D, Hazardous Locations or Non-Hazardous Locations. ATEX Warnings and Conditions of Safe Usage: Power, Input, and Output (I/O) wiring must be in accordance with the authority having jurisdiction AWarning - Explosion Hazard - When in hazardous locations, turn off power before replacing or wiring modules.BWarning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous.CThese products are intended to be mounted in an IP54 enclosure. The devices shall provide external means to prevent the rated voltage being exceeded by transient disturbances of more than 40%. This device must be used only with ATEX certified backplanes.DDO NOT OPEN WHEN ENERGIZED. Markings Hardware Ratings Backplane Current Load: 800 mA @ 5 VDC; 3 mA @ 24 VDC Operating Temperature:For standard MVI56E modules: 0C to 60C (32F to 140F) For MVI56E XT (conformal coated): -25C to 70C (-13F to 158F) Storage Temperature: -40C to 85C (-40F to 185F)Shock: 30 g operational; 50 g non-operational; Vibration: 5 g from 10 to 150 HzRelative Humidity: 5% to 95% (without condensation) All phase conductor sizes must be at least 1.3 mm (squared) and all earth ground conductors must be at least 4mm (squared). MVI56E XT module comes with conformal coating installed. Label Markings E183151 Class I, DIV 2, groups A,B,C,D T5 for all models 0C to +60C -25C to +70C (XT models only) II 3 G Ex nA T5 0C 200 words, Block ID 0 is not used. If Read Register Count in the module configuration file is set >0 and