Page 1: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

1 May 2014

Page 2: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

Table of Contents

1 Mystik Canopy/Island Image Guidelines

4 Mystik Pump Image Guidelines

6 Mystik Building Image Guidelines

7 Sign System: 6x6

8 Sign System: 5x5

9 Sign System: 5x10

9 Sign System: 4x8

10 12'UniversalPoleSpecifications

11 Mystik Material List

Page 3: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

1 May 2014

Mystik Canopy/Island Image Guidelines

Primary Fascia ElevationMystik Red

Wordmark

Island CurbMystik BronzeBollards

Mystik Medium Red

Primary X-Form

Secondary Fascia ElevationSecondary X-Form

Mystik Bronze

Page 4: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

2 May 2014

Mystik Canopy/Island Image Guidelines

Tools Required

•UtilityBlade•MarkerorPencil•PinorNeedle•PlasticSqueegee•Sponge•RivetBrush

•RulerorTape•MaskingTape•IsopropylAlcohol•SoapandWater•PaperTowels•IndustrialHeatGun

Red and X-Form Decals Application

Step1:InstallMystikredsolidvinylallaroundthe canopy (provided in 8’ sections).

Afterapplyingthedecalsonthecanopy,all canopyseamsshouldbecutandtuckedinto theseamwiththesqueegeeedge.

Step2:Determinewhetherthefasciaisprimaryor secondary,basedonvisibility/order.

InstalltheX-Formson1primaryand1 secondaryside.MakesuretheX-formsmeet andlineupontheedgewherethesecondary and primary meet.

Step3:InstalltheMystikwordmarkfromtheright edgeoftheprimarysideandcenteredtopto bottom.

Distanceofthewordmarkfromtheright edgeisdeterminedbythecanopyfascia height.Refertoillustrationaboveand charttotheright.

***Mystik wordmark must not intrude into the X-Form

Surface Preparation

1.Surfacemustbeabove50oFandbelow100oF. Surfacemaybeheatedorcooledmechanically beforeapplication.

2.Liftedorlooseedgesmustbetrimmedand smoothpriortoapplication.

3.Cleansurfacewithsoapandwater.Rinseanddry.

4.Cleansurfacewithisopropylalcoholusinglint-free papertowels.

25’w x 40”h

21”w

25’w x 40”h

24.15”h

19.258”h

76.57”w

OVERVIEW OF A FINISHED IMAGED CANOPY

CANOPY VINYL LETTER DECAL SIZING

Canopy Fascia Heights Letter Spacing From Right EdgeMystik Vinyl Letter Size

0"-29"Custom -

Please consult yourCITGO Region Brand Manager

30"-39" 24" 21"

40"-49" 33" 28"

>50"Custom -

Please consult yourCITGO Region Brand Manager

Custom - Please consult your

CITGO Region Brand Manager

Custom - Please consult your

CITGO Region Brand Manager

Page 5: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

3 May 2014

Application Instructions

1.Applyamaskingtapehingeverticallyatthecenter ofthedecal.(FIGURE1)

2.Foldhalfofthedecalhinge,peelofflinertotape hinge,cutlineralonghingeanddiscard. (FIGURE2)

3.Foldbackholdingdecaloffsurface.Startingat centeroftapehinge,squeegeedecalusingvery firm,verticaloverlappingstrokes.Throughout applicationkeeptheunappliedportionofthe decaloffthesurface,allowingittotouchonly fromsqueegeepressure.(FIGURE3)

4.Whileapplyingthedecalsonthecanopy,ensure thatallcanopyseams are cut and tucked into theseamwithsqueegeeedge.(FIGURE4)

5.Removemaskingtapehingeandtheremaining liner.Repeatstep3.

6.Continueapplyingdecalsoverlappingeachone 1/8"to3/16".Trimwithrazorbladeifnecessary.

7.Wipewithpapertowel.(FIGURE5)

Finishing

1. Puncture decal in several places around rivet heads.Pressoutairwithsqueegee.

2.Userivetbrushandheatfromanindustrialheat guntomakethedecalconformtotherivethead. (FIGURE6)

3.Removewhitepaperpremaskbypullingitback ontoitself.(FIGURE7)

4.Eliminateairbubblesbypuncturingdecalat theedgeofthebubble(notthecenter)withapin or needle.

5.Pressouttheentrappedairstartingattheopposite edgefromthepuncture.(FIGURE8)

6.Re-squeegeealledgesandoverlaps.Reheatand userivetbrushtosealfilmoverrivets.

Mystik Canopy/Island Image Guidelines

FIGURE 3

FIGURE 7

FIGURE 6

FIGURE 8

Panel Seam

FIGURE 5

FIGURE 1 FIGURE 2

Panel Seam

FIGURE 4

Page 6: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

4 May 2014

Mystik Pump Image Guidelines

72

2.5”

2.5”

2.5”

2.5”

2.5”

2.5”

• Removeexistinggraphicsonthedispensers.

• Prepandcleansurfacepriortoinstallation. Thesurfacemustbecleanandsmoothand freeofanywaxorsilicone,oxidationorloose flakingpaint.

• Surfaceandairtemperature:Minimumof50oF

• Valancedecalsareprovidedin3pieces.

• X-Formsaretobeinstalledonthefrontfaceofthe pumpandsideswillbesolidredvinyl.Youwill have2piecesofgraphicstowrap1valance.Trim any excess material.

• InstalltheMystikwordmark2.5"awayfrom therightedgeofthefrontfaceofthevalanceand centeredtopandbottom.

Wordmark Produced & Applied Separately2.5” From Right Front Edge of Valance

Side ofValance

Front of Valance (36”W)

2.5”

6.5”

8”

OVERVIEW OF FINISHED PUMP DISPENSER (3 HOSE)

Dieselpumpswillbeimagedwithgraphicspicturedatright:(onesizedecalcuttofit)

Product Dispenser Decals-RefertoCITGODecal Image Standards

72

2.5”

2.5”

2.5”

OVERVIEW OF FINISHED PUMP DISPENSER (1 HOSE)

Page 7: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

5 May 2014

Mystik Pump Image Guidelines

2.5” Wordmark Produced & Applied Separately2.5” From Left and Top Edges

Dashed Line Indicates 42”W x 37.25”H Visual Area

2.5”

5”

4.375”

16”

Pumpskirt Decal for Gas Pumps Only

• Removeexistinggraphicsonthedispensers.

• Prepandcleansurfacepriortoinstallation. Thesurfacemustbecleanandsmoothand freeofanywaxorsilicone,oxidationorloose flakingpaint.

• Pumpskirtdecalsareprovidedin2pieces.

• Installthegraphicsbyliningupthebottomleft edgeofthepump.Wraptheentiredoorwiththe graphics,includingthesidereturnsonthedoor. Trimanyexcessmaterial.

• InstalltheMystikwordmark2.5"awayfromthe topandleftsideedgeofthedoor.Seephotos onpreviouspageforplacementonasinglehose versusa3-hosedispenser.

• Refertovisualimageabove.

• Installallotherpumpgraphicsprovidedfor thedispensers,includingoctanedecals,federal warningdecalsandproductIDdecals.

• Removepumptoppersonthe currentdispensers.• Risersmustbecleanandfreeofvinyl.• Canopysupportpolesandislandcurbs paintedMystikBronze.• IslandguardpolespaintedMystik MediumRed.• SigncabinetsandsignpolespaintedMystikBlack.

Page 8: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

6 May 2014

Mystik Building Image Guidelines

36”H Fascia

Mystik Red Stripe DecalSupplied in 8’ Sections

CIT MRD40

Credit Card Door Decal

Panel Seam

1.Removeallexistinggraphicsandcleanareaprior to installation.

2.InstallMystikredvinyl.Theseareprovidedin 8' sections.

3.Mystiklogoistobecenteredtoptobottomand lefttorightonthefrontfascia.

Afterapplyingthedecalsonthebuildingfascia,allfasciaseamsshouldbecutandtuckedintotheseamwiththesqueegeeedge.(Seeillustrationbelow)

Panel Seam

PleasecontactyourRegionBrandManagerwithanyquestions:

CentralRegionTeddHupp:832-486-1966Email:[email protected]

CentralRegionEricKolber:832-486-5947Email:[email protected]

NortheastRegionSuePascarella:832-486-5717Email:[email protected]

SouthernRegionSusanEdge:832-486-1995Email:[email protected]

Note: Mystik image is required only if the building has any other brand image elements at the time of conversion.

Page 9: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

7 May 2014

Sign System: 6x6

REGULARUNLEADED

MID GRADEUNLEADED

SUPERPREMIUM

SIGN SPECIFICATIONSAmps: 7.0Net Weight:6’ x 6’ sign: 190 lbs.6’ x 6’ sign: 190 lbs.Total Weight: 380 lbs.Area: 72 square feetCabinet color: Mystik Black

POLE & FOUNDATION SPECIFICATIONSDesign Windload: 30 PSF/100 MPHPole Supports: 8” x 6” x 3/16” W.T. x 24’ tubesBaseplates: 1 1/4” x 9” x 15”Anchor Bolts: 1” x 42”Foundation: 2’-6” Dia. x 7’-3” Deep

Amps: 3.49Watts: 380Net Weight: 190 lbs.Area: 36 S.F.Lumens: 1050 P.S.F.

(6) F72T12 H.O.C.W. Lamps

(1) Electronic Ballast (3.49 amps)

"8/5 37

"0-'6"0-'6

72 15/16"

6'-0"

79”

73”

30” Dia. Caisson

6”x8” Steel Tube

Concrete PierFoundations100MPH (30psf)

3”x5”ReinforcedHandhole3/4” Dia. Rigid Conduit

(one caisson only)

#4 Rebar Ties12” O.C.

(5) #5 Rebars, 6’-3” longequally spaced around an24” dia. circle

(4) 1” Dia. x 42” long Anchor BoltsEach bolt has (2) nuts & (2) washers

7’-3

”D

eep

"61/1 71

"0-'4211 1/2"

6x6 SIGN PRICE SIGN FONT3 PRODUCT D/F

6’x6’MystikID Sign

6’x6’3 ProductPrice Sign

Front Elevation

"61/1 7111 1/2"

Mystik Black

Page 10: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

8 May 2014

Sign System: 5x5SIGN SPECIFICATIONSAmps: 7.0Net Weight:5’ x 5’ sign: 145 lbs.5’ x 5’ sign: 145 lbs.Total Weight: 290 lbs.Area: 50 square feetCabinet color: Mystik Black

POLE & FOUNDATION SPECIFICATIONSDesign Windload: 30 PSF/100 MPHPole Supports: 8” x 6” x 3/16” W.T. x 24’ tubesBaseplates: 1 1/4” x 9” x 15”Anchor Bolts: 1” x 42”Foundation: 2’-6” Dia. x 7’-3” Deep

Amps: 3.49Watts: 340Net Weight: 145 lbs.Area: 25 S.F.Lumens: 1296 P.S.F.

(5) F60T12 H.O.C.W. Lamps

(1) Electronic Ballast (3.49 amps)

66 1/4”

60 1/4”

30” Dia. Caisson

6”x8” Steel Tube

Concrete PierFoundations100MPH (30psf)

3”x5”ReinforcedHandhole3/4” Dia. Rigid Conduit

(one caisson only)

#4 Rebar Ties12” O.C.

(5) #5 Rebars, 6’-3” longequally spaced around an24” dia. circle

(4) 1” Dia. x 42” long Anchor BoltsEach bolt has (2) nuts & (2) washers

7’-3

”D

eep

"0-'425x5 SIGN PRICE SIGN FONT

3 PRODUCT D/F

5’x5’MystikID Sign

5’x5’3 ProductPrice Sign

Front Elevation

”0-’5”0-’5

5’-0”

"51

10 1/2"

REGUNLD

SUPERPREM

MIDUNLD

"8/3 16

60 1/4"

"51

10 1/2"

Mystik Black

Page 11: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

9 May 2014

Sign System: 5x10

SIGN SPECIFICATIONSAmps: 7.0Net Weight: 280 lbs.Area: 50 square feetWatts: 680Lumens: 1100 P.S.F.Cabinet color: Mystik Black

SIGN SPECIFICATIONSAmps: 2.34Net Weight: 180 lbs.Area: 32 square feetWatts: 420Lumens: 1150 P.S.F.Cabinet color: Mystik Black

(10) F60T12 H.O.C.W. Lamps

(5) F96T12 H.O.C.W. Lamps

(4) F96T12 H.O.C.W. Lamps(4) F96T12 H.O.C.W. Lamps

(2) F60T12 H.O.C.W. Lamps

(2) Electronic Ballast (@ 3.49 amps)

(2) Electronic Ballast (@ 3.49 amps)

(1) Electronic Ballast (2.34 amps)(1) Electronic Ballast (2.34 amps)

M-SS-5x10BBETWEEN POLE MOUNT

M-SS-4x8BBETWEEN POLE MOUNT

M-SS-5x10CCENTER POLE MOUNT

M-SS-4x8CCENTER POLE MOUNT

PRICE SIGN FONT3 PRODUCT D/F

PRICE SIGN FONT3 PRODUCT D/F

"4/3 11

8 1/2"

"4/1 05

"4/1 05

97 5/8"97 5/8"

”0-’4

8’-0”

"51

10 1/2"

"16

"8/3 16

119"119 1/4"

”0-’5

10’-0”

REGUNLD

SUPERPREM

MIDUNLD

REGUNLD

SUPERPREM

MIDUNLD

Sign System: 4x8

Page 12: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

10 May 2014

12' Universal Pole Specifications: 5'x10' and 4'x8' Sign Systems

Foundation Design Notes1. Concreteshallhaveaminimumcompressive

strengthof3,000PSIat28days.2. ReinforcingbarsshallbeASTMA615grade60

steel.3. Concretefootingsaredesignedusingasoil-

bearingforceof250lbs./sq.ft.perfootofdepthlateral.Ifthissoilconditiondoesnotexist,itistheErector'sresponsibilitytohaveanewbasedesignedfortheexistingsoilconditionsbyaLicensedStructuralEngineer.

4. AnchorboltsaretobemanufacturedaccordingtoAASHTOspecificationM314-90grade55.

Page 13: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

11 May 2014

Material List

CANOPY

MC100 24” Mystik Decal

MC101 33” Mystik Decal

MPXD40 RedCanopyOverlay,40”x96”Decal

MPXD50 RedCanopyOverlay,50”x96”Decal

MPXP40 40”PrimaryX-FormDecalKit

MPXP50 50”PrimaryX-FormDecalKit

MPXS40 40”SecondaryX-FormDecalKit

MPXS50 50”SecondaryX-FormDecalKit

PUMPS

MQ305 Valance,DecalSet13”x92”withMystik

MQ307 PumpSkirt(1side)32”x52”RedVinylwithMystik

MPX203 BlackDecal(1side)40”x96”OverlayPumpNozzelArea

RefertoPumpImageStandards,Section3inyourCITGOImageStandardsandInstallationGuidelinesbinder,forappropriatefederallabeling,Safetyandinformationdecals,environmentaldecals,pumpnumberdecals,productIDsandoctanedecals.

SIGNS

NM-SS-4X8,3P 4’x8’CompleteSignSystem,ID,3Products,Regular,Mid,Super,Fonts,PoleChanger

NM-SS-4X8,1P 4’x8’CompleteSignSystem,ID,1Product,Regular,Fonts,PoleChanger

NM-SS-5X10,3P 5’x10’CompleteSignSystem,ID,3Products,Regular,Mid,Super,Fonts,PoleChanger

NM-SS-5X10,1P 5’x10’CompleteSignSystem,ID,1Product,Regular,Fonts,PoleChanger

NM-SS-5X5,3P 5’x5’BetweenthePoles,CompleteSignSystem,ID,3Products,Regular,Mid,Super,Fonts,PoleChanger

NM-SS-6X6,3P 6’x6’BetweenthePoles,CompleteSignSystem,ID,3Products,Regular,Mid,Super,Fonts,PoleChanger

PAINT

BP9534BZ BronzeGloss,Water-BaseEnamel(CanopyPoles,Curbs)

CC2312RED MediumRedGloss,Water-BaseEnamel(Bollards)

CC2669 CITGOBlackGloss,Water-BaseEnamel(SignPoles)

Page 14: Mystik Image Standards and Installation Guidelines...5. Remove masking tape hinge and the Panel Seamremaining liner. Repeat step 3. 6. Continue applying decals overlapping each one

12 May 2014

©2014 CITGO Petroleum CorporationMystik, as well as the Mystik logo, trade name and trade dress, and all related marks are registered trademarks of CITGO Petroleum Corporation.CITGO Petroleum Corporation does not own, operate or maintain the retail locations bearing the Mystik logo, trade name and trade dress.

BD_140217_004