EXISTING POOL MECHANICAL ROOM DEMOLITION PLAN MR.1 (E) SPA FILTERS TO REMAIN (E) SPA CIRC. PUMPS TO REMAIN (E) SPA BOOSTER PUMPS TO REMAIN (E) SPA PULSAR CHLORINATION SYSTEM TO REMAIN (E) BOOSTER PUMP TO REMAIN (E) SPA BECSYS 3 WATER CHEMISTRY CONTROLLER TO REMAIN. (E) SPA HEAT EXCHANGER TO REMAIN (E) LAP POOL HEAT EXCHANGER TO REMAIN (E) DIVE POOL HEAT EXCHANGER TO REMAIN (E) 2'' HEAT EXCHANGER INFLU./EFFLU. (E) 2'' HEAT EXCHANGER INFLU./EFFLU. (E) DIVE POOL BECSYS 3 WATER CHEMISTRY CONTROLLER TO BE REMOVED AND REPLACED PER PLAN. (E) SINKS (E) LAP POOL BECSYS 3 WATER CHEMISTRY CONTROLLER TO BE REMOVED AND REPLACED PER PLAN. (E) 4'' SPA BACKWASH (E) 6'' BACKWASH (E) 36'' SQUARE WASTE TANK RECEPTOR (E) 6'' WASTE (E) 8'' WASTE DISPOSAL (E) 8'' WASTE LINE (E) LAP POOL FILTERS , VALVES AND ASSOCIATED PLUMBING TO BE REMOVED AND REPLACED PER PLAN. (E) 4'' BACKWASH (E) BFV (E) BFV (E) 6'' REPAIR OR REPLACE ANY DAMAGED ITEMS DUE TO DEMOLITION AND/OR CONSTRUCTION. COORDINATE INGRESS/EGRESS AND HAUL ROUTES WITH THE CONTRACTOR PRIOR TO START OF WORK. THIS PLAN VIEW IS SHOWN FOR INFORMATION AND ASSISTANCE. THE CONTRACTOR IS RESPONSIBLE FOR INDIVIDUAL DIMENSIONS, ELEVATIONS, TAKE-OFFS AND ESTIMATIONS WITH REGARD TO DEMOLITION, PREPARATION, AS WELL AS MEANS AND METHODS OF CONSTRUCTION AND SHALL VISIT THE SITE AS REQUIRED TO ACCOMPLISH THE WORK, AND TO BECOME FAMILAR WITH SCOPE AND SERVICES OF WORK REQUIRED. COORDINATE DEMOLITION WORK WITH THE OWNER, PROTECT ALL EXISTING WORK, BUILDINGS, PIPING, EQUIPMENT, UTILITIES, ETC. TO REMAIN. 1 2 3 4 THE OWNER SHALL IDENTIFY, REMOVE AND SALVAGE ANY ITEMS AS DESIRED PRIOR TO CONTRACTOR MOVE-IN. 5 COORDINATE DEMOLITION AND POINTS OF CONNECTION WITH EXISTING UTILITIES, AND PIPING SYSTEMS IN THE FIELD TO ALLOW NEW WORK TO BE ACCOMPLISHED IN THE BEST FASHION. 6 CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND HAULING OFF OF ALL MECHANICAL EQUIPMENT, PIPING, VALVING, AND THE LIKE, AND LEGALLY DISPOSING OF ALL SUCH MATERIAL FROM THE SITE AS PART OF THE OVERALL BASE BID. LEAVE ADEQUATE PLUMBING LENGTH DURING DEMO FOR POC TO NEW PLUMBING. 7 8 (E) 6'' BFV (E) BFV (E) CV (E) BFV (E) BFV (E) CV (E) BFV (E) BV (E) BV (E) BFV (E) (E) 2'' HEAT EXCHANGER INFLU./EFFLU. (E) 2'' HEAT EXCHANGER INFLU./EFFLU. (E) LAP POOL CIRC. PUMP TO BE REMOVED AND REPLACED PER PLAN. (E) LAP POOL CIRC. PUMP STRAINER TO BE REMOVED AND REPLACED PER PLAN. (E) DIVE POOL CIRC. PUMP TO BE REMOVED AND REPLACED PER PLAN. (E) DIVE POOL CIRC. PUMP STRAINER TO BE REMOVED AND REPLACED PER PLAN. EXISTING 4'' CONCRETE PAD TO REMAIN. PREP AREA FOR NEW PUMPS. EXISTING VARIABLE SPEED DRIVES TO BE REMOVED AND REPLACED PER PLAN. BFV (E) (E) 8'' (E) 6'' 6'' (E) (E) 1'' CHLORINE FEEDS TO BE REMOVED BFV (E) (E) DIVE POOL PULSAR CHLORINE STORAGE, VALVING AND ASSOCIATED PIPING TO BE REMOVED AND REPLACED PER PLAN. (E) 1'' CHLORINE FEEDS TO BE REMOVED (E) 6'' LAP POOL FLOOR INLET RETURN (E) 8'' LAP POOL SURGE CHAMBER SUCTION (E) 6'' DIVE POOL FLOOR INLET RETURN (E) 6'' LAP POOL SURGE CHAMBER SUCTION 6'' (E) (E) 2'' HEAT EXCHANGER INFLU./EFFLU. (E) 4'' BACKWASH BFV (E) BFV (E) BFV (E) BFV (E) (E) 6'' BACKWASH (E) 6'' BACKWASH (E) 6'' BACKWASH 6'' (E) 6'' (E) (E) LAP POOL PULSAR CHLORINE STORAGE, VALVING AND ASSOCIATED PIPING TO BE REMOVED AND REPLACED PER PLAN. (E) BOOSTER PUMPS TO BE REMOVED (E) 2'' HEAT EXCHANGER INFLU./EFFLU. VALVES AND ASSOCIATED PLUMBING TO BE REMOVED AND REPLACED PER PLAN. (E) DIVE POOL FILTERS, (E) 4'' BACKWASH 8'' (E) 8'' (E) 8'' (E) (E) 4'' BACKWASH (E) 8'' BV (E) BV (E) CV (E) (E) POOL MECHANICAL ROOM 1 2 3 4 6 7 8 5 (E) = EXISTING BFV = BUTTERFLY VALVE CV = CHECKED VALVE BV = BALL VALVE {''=1'-0'' NORTH c woofter architecture 2018 woofter architecture 107 SE Washington Street, Suite 228 Portland, OR 97214 503 724 0111 Revisions Project No. Date OSU DRC AQUATICS IMPROVEMENTS 644 SW 13TH AVENUE, CORVALLIS, OR 97333 OREGON STATE UNIVERSITY 644 SW 13th AVENUE CORVALLIS, OR 97333 01/07/20 07601 R E N E I N E G L A N E I S S O R O P F D R E G S I T R E E 74816PE OREGON M a y 11, 0 2 0 4 D OU G L A S E F E R L L R EXPIRATION DATE: (E) PNL 'P4' (E) PNL 'P3' (E) PNL 'P2' (E) PNL 'P1' (E) PNL 'L' (E) LIGHTING RELAY

Upload: others

Post on 29-May-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NAL OSI4 SE 0 F 2 ORPD y E Ma ERTSIGER

EXISTING POOL

MECHANICAL ROOM

DEMOLITION PLAN

MR.1

(E) SPAFILTERSTO REMAIN

(E) SPACIRC. PUMPSTO REMAIN

(E) SPABOOSTER PUMPSTO REMAIN

(E) SPA PULSARCHLORINATIONSYSTEM TO REMAIN

(E) BOOSTERPUMP TOREMAIN

(E) SPA BECSYS 3WATER CHEMISTRYCONTROLLER TOREMAIN.

(E) SPA HEATEXCHANGERTO REMAIN

(E) LAP POOLHEAT EXCHANGERTO REMAIN

(E) DIVE POOLHEAT EXCHANGERTO REMAIN

(E) 2'' HEATEXCHANGERINFLU./EFFLU.

(E) 2'' HEATEXCHANGERINFLU./EFFLU.

(E) DIVE POOL BECSYS 3WATER CHEMISTRYCONTROLLER TO BEREMOVED AND REPLACEDPER PLAN.

(E) SINKS

(E) LAP POOL BECSYS 3WATER CHEMISTRYCONTROLLER TO BEREMOVED AND REPLACEDPER PLAN.

(E) 4'' SPABACKWASH

(E) 6'' BACKWASH

(E) 36'' SQUARE WASTE TANKRECEPTOR

(E) 6'' WASTE

(E) 8'' WASTE

DISPOSAL(E) 8'' WASTE

LINE

(E) LAP POOL FILTERS , VALVESAND ASSOCIATED PLUMBING TO BE REMOVED AND REPLACED PER PLAN.

(E) 4'' BACKWASH

(E) BFV (E) BFV

(E) 6''

REPAIR OR REPLACE ANY DAMAGED ITEMS DUE TO DEMOLITION AND/OR CONSTRUCTION.

COORDINATE INGRESS/EGRESS AND HAUL ROUTES WITH THE CONTRACTOR PRIOR TO START OF WORK.

THIS PLAN VIEW IS SHOWN FOR INFORMATION AND ASSISTANCE. THE CONTRACTOR IS RESPONSIBLE FORINDIVIDUAL DIMENSIONS, ELEVATIONS, TAKE-OFFS AND ESTIMATIONS WITH REGARD TO DEMOLITION,PREPARATION, AS WELL AS MEANS AND METHODS OF CONSTRUCTION AND SHALL VISIT THE SITE ASREQUIRED TO ACCOMPLISH THE WORK, AND TO BECOME FAMILAR WITH SCOPE AND SERVICES OF WORKREQUIRED.

COORDINATE DEMOLITION WORK WITH THE OWNER, PROTECT ALL EXISTING WORK, BUILDINGS, PIPING,EQUIPMENT, UTILITIES, ETC. TO REMAIN.

1

2

3

4

THE OWNER SHALL IDENTIFY, REMOVE AND SALVAGE ANY ITEMS AS DESIRED PRIOR TO CONTRACTOR MOVE-IN.5

COORDINATE DEMOLITION AND POINTS OF CONNECTION WITH EXISTING UTILITIES, AND PIPING SYSTEMS INTHE FIELD TO ALLOW NEW WORK TO BE ACCOMPLISHED IN THE BEST FASHION.

6

CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND HAULING OFF OF ALL MECHANICAL EQUIPMENT,PIPING, VALVING, AND THE LIKE, AND LEGALLY DISPOSING OF ALL SUCH MATERIAL FROM THE SITE AS PARTOF THE OVERALL BASE BID.

LEAVE ADEQUATE PLUMBING LENGTH DURING DEMO FOR POC TO NEW PLUMBING.

7

8

(E) 6''

BFV(E)

BFV(E)

CV(E)

BFV(E)

BFV(E)

CV(E) BFV(E)

BV(E)

BV(E)

BFV(E)(E) 2'' HEAT

EXCHANGERINFLU./EFFLU.

(E) 2'' HEATEXCHANGERINFLU./EFFLU.

(E) LAP POOL CIRC.PUMP TO BE REMOVED AND REPLACED PER PLAN.

(E) LAP POOL CIRC.PUMP STRAINER TO BE REMOVED AND REPLACED PER PLAN.

(E) DIVE POOL CIRC.PUMP TO BE REMOVED AND REPLACED PER PLAN.

(E) DIVE POOL CIRC.PUMP STRAINER TO BE REMOVED AND REPLACED PER PLAN.

EXISTING 4''CONCRETE PADTO REMAIN.PREP AREA FORNEW PUMPS.

EXISTING VARIABLESPEED DRIVES TO BEREMOVED ANDREPLACED PER PLAN.

BFV(E)

(E) 8''

(E) 6''

6''(E)

(E) 1'' CHLORINEFEEDS TOBE REMOVED

BFV(E)

(E) DIVE POOLPULSAR CHLORINESTORAGE, VALVINGAND ASSOCIATED PIPINGTO BE REMOVED ANDREPLACED PER PLAN.

(E) 1'' CHLORINEFEEDS TOBE REMOVED

(E) 6'' LAP POOL FLOOR INLET RETURN

(E) 8'' LAP POOL SURGE CHAMBER SUCTION

(E) 6'' DIVE POOL FLOOR INLET RETURN

(E) 6'' LAP POOL SURGE CHAMBER SUCTION

6''(E)

(E) 2'' HEATEXCHANGERINFLU./EFFLU.

(E) 4'' BACKWASH

BFV(E)

BFV(E)

BFV(E)

BFV(E)

(E) 6'' BACKWASH

(E) 6'' BACKWASH

(E) 6'' BACKWASH

6''(E)

6''(E)

(E) LAP POOLPULSAR CHLORINESTORAGE, VALVINGAND ASSOCIATED PIPINGTO BE REMOVED ANDREPLACED PER PLAN.

(E) BOOSTER PUMPS TO BE REMOVED

(E) 2'' HEATEXCHANGERINFLU./EFFLU.

VALVES AND ASSOCIATEDPLUMBING TO BE REMOVED AND REPLACED PER PLAN.

(E) DIVE POOL FILTERS,

(E) 4'' BACKWASH

8''(E)

8''(E)

8''(E)

(E) 4'' BACKWASH

(E) 8''

BV(E)

BV(E)

CV(E)

(E) POOL MECHANICALROOM

1 2 3 4

6 7 85

(E) = EXISTING

BFV = BUTTERFLY VALVE

CV = CHECKED VALVE

BV = BALL VALVE

{''=1'-0''

NORTH

c w

oofter architecture 2018

wo

ofte

r a

rc

hite

ctu

re

107 S

E W

ashington S

treet, S

uite 228

Portland, O

R 97214

503 724 0111

Revisions

Project No.

Date

OSU

DR

C A

QU

ATI

CS

IMPR

OV

EMEN

TS6

44

S

W 1

3T

H A

VE

NU

E,

CO

RV

AL

LIS

, O

R 9

73

33

OR

EG

ON

ST

AT

EU

NIV

ER

SIT

Y6

44

S

W 1

3th

A

VE

NU

E

CO

RV

AL

LIS

, O

R 9

73

33

01/07/20

07601

RE

NE

IN

EG

LAN

EISS

O

R

O

PF

DR

EGSI

T

R

EE 74

816P

E

OR

EG

ON

Ma

y11

,0

204

DOU

GL A

SE

FE

RLL

R

EX

PIR

ATI

ON

DA

TE:

(E) PNL 'P4'

(E) PNL 'P3'

(E) PNL 'P2'

(E) PNL 'P1'

(E) PNL 'L'

(E) LIGHTING RELAY

AutoCAD SHX Text
DEMOLITION NOTES
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
1
AutoCAD SHX Text
EXISTING POOL MECHANICAL ROOM DEMOLITION PLAN
Page 2: NAL OSI4 SE 0 F 2 ORPD y E Ma ERTSIGER

MECHANICAL ROOM

LAYOUT PLAN

MR.2

(E) SPAFILTERSTO REMAIN

(E) SPACIRC. PUMPSTO REMAIN

(E) SPABOOSTER PUMP

(E) SPA PULSARCHLORINATION

(E) SPA BOOSTERPUMP

(E) SPA BECSYS 3WATER CHEMISTRYCONTROLLER TOREMAIN.

(E) SPA HEATEXCHANGERTO REMAIN

(E) LAP POOLHEAT EXCHANGER

(E) DIVE POOLHEAT EXCHANGER

(N) DIVE POOL BECSYS 5WATER CHEMISTRYCONTROLLER

(E) SINKS

(N) LAP POOL BECSYS 5WATER CHEMISTRYCONTROLLER

(E) 36'' SQUARE WASTE TANKRECEPTOR

(E) 6'' WASTE

(E) 8'' WASTE

DISPOSAL(E) 8'' WASTE

LINE

(N) LAP POOL FILTERS

(N) LAP POOL CIRC. PUMP

(N) DIVE POOL CIRC. PUMP

EXISTING 4''CONCRETE PAD

(N) DIVE POOL VARIABLESPEED DRIVE

(N) DIVE POOL FILTERS

(E) POOL MECHANICALROOM

{''=1'-0''

NORTH

c w

oofter architecture 2018

wo

ofte

r a

rc

hite

ctu

re

107 S

E W

ashington S

treet, S

uite 228

Portland, O

R 97214

503 724 0111

Revisions

Project No.

Date

OSU

DR

C A

QU

ATI

CS

IMPR

OV

EMEN

TS6

44

S

W 1

3T

H A

VE

NU

E,

CO

RV

AL

LIS

, O

R 9

73

33

OR

EG

ON

ST

AT

EU

NIV

ER

SIT

Y6

44

S

W 1

3th

A

VE

NU

E

CO

RV

AL

LIS

, O

R 9

73

33

12/16/19

07601

RE

NE

IN

EG

LAN

EISS

O

R

O

PF

DR

EGSI

T

R

EE 74

816P

E

OR

EG

ON

Ma

y11

,0

204

DOU

GL A

SE

FE

RLL

R

EX

PIR

ATI

ON

DA

TE:

(N) U.V.

(N) DIVE POOL / LAP POOL CHLORINE STORAGE/FEED SYSTEM(S): PROVIDE 'PPG' ACCU-TAB POWERBASE CHLORINATIONUNIT MODEL 1030 SPA WITH 84lbs/DAY OUTPUT COMPLETE WITH 1 HP BOOSTER PUMP, PIPING, VALVING AND VENTURIINJECTION. TWO (2) SYSTEM TOTAL.

71-2

MR.43-4MR.3

(N) DIVE POOL / LAP POOL ULTRA VIOLET TREATMENT SYSTEM(S): 'ETS' ECF-215-6V, VALIDATED AT 665 GPM, 6'' FLANGED CONNECTIONIN-LINE UV WITH TWO (2) LAMP @ 1,500 WATTS, 480V 3PH. CONTROL UNIT: ECF-A-40, 480V 3 PH, 24''x40''x12'' DEEP. ONE (1) TOTAL.PROVIDE PIPING BYPASS, VALVING, ETS EZ VALVE STRAINER AND INSTALLATION AND PIPING PER MANUFACTURER'S RECOMMENDATIONS.TWO (2) SYSTEM TOTAL.

56

MR.3

1 (N) POOL / RECREATIONAL POOL STRAINER(S): 'MER-MADE' F.O. SERIES FRP REDUCING BASKETSTRAINER: THREE (3) 6''x5'' STANDARD WITH ACRYLIC LID AND THREE (3) STAINLESS STEEL STRAINERS EA.(150lbs.) THREE (3) TOTAL.

3 (N) LAP POOL CIRCULATION PUMP: 'PACO' #4095-7, 4''x5''x9\'' TYPE 'LC' END SUCTION CENTRIFUGAL PUMP; 1,750 RPM 460V, 3PH; 15HP;RATED AT 475 GPM @ 70 FT. TDH; 78% EFFICIENT; PREMIUM EFFICIENCY TEFC MOTOR; EPOXY COAT ALL WET SURFACES. 'PACO','AURORA' OR APPROVED EQUAL. (300 lbs.) PROVIDE 'SPCS' SMART PUMP CONTROL SYSTEM VARIABLE SPEED DRIVE MODELSPCS015EF4 SYSTEM 21''x41''x14'' DEEP. COORDINATE MOUNTING LOCATION TO MAINTAIN DESIRED CLEARANCES, 460V 3PH. (100 lbs.)

27-8MR.4 (N) DIVE POOL CIRCULATION PUMP(S): 'PACO' #2595-7, 2\''x3''x9\'' TYPE 'LC' END SUCTION CENTRIFUGAL

PUMP 1750 RPM 460V, 3PH 7\HP RATED AT 240 GPM @ 70 FT. TDH 76% EFFICIENT PREMIMUMEFFICIENCY TEFC MOTOR EPOXY COAT ALL WET SURFACES. TWO (2) TOTAL. 'PACO', 'AURORA' OR EQUAL.(240 lbs.) PROVIDE 'SPCS' EkO-FLEX PUMP CONTROL SYSTEM VARIABLE SPEED DRIVE MODELSPCS007EF4 SYSTEM 15''x35''x14'' DEEP. COORDINATE MOUNTING LOCATION TO MAINTAIN DESIREDCLEARANCES, 460V 3PH. (128 lbs.)

(N) DIVE POOL / LAP POOL WATER CHEMISTRY CONTROLLERS: PROVIDE ONE (1) DEDICATED ETHERNETCONNECTION FOR 'BECKSys' RCM SYSTEM 5 WITH AUTO PROBE RINSE. PROVIDE NEW INTERCONNECTS WITHCONTROLLER FOR NEW CIRCULATION PUMPS, VARIABLE SPEED DRIVES, CHEMICAL SYSTEMS AND FILTERBACKWASH CONTROLLERS. TWO (2) TOTAL.

82-5MR.4

SYSTEM

(N) 4'' HOUSEKEEP PAD

(N) LAP POOL VARIABLESPEED DRIVE

(N) CHLORINESTORAGE FEEDSYSTEM

(N) U.V.SYSTEM

EXTINGUISHER(E) FIRE

U.V. CONTROLPANEL

(N) LAP POOL(E) POOL MECHANICALROOM (BASEMENT LEVEL)

(E) NATATORIUM BUILDINGOUTLINE (FIRST FLOOR LEVEL)

(E) HATCH ABOVE FORBASEMENT ACCESS

(E) CO2 AREA

2

3

54

4

8

8

7

LAP POOL CIRCULATION PUMP: 15 HP @ 460V. = 21.0 AMPSDIVE POOL CIRCULATION PUMP: 7\ HP @ 460V. = 11.0 AMPS

DIVE POOL CIRCULATION PUMP: 7\ HP @ 460V. = 11.0 AMPS

}'' DIA.

{'' DIA.

\'' DIA.

SIZE

800

3,000

1,500

4,900

TENSION LOAD (LBS)

60

40

10

25

3|''

4''

2''

2''

MIN. EMBED

['' DIA. 6,300 1104[''

|'' DIA.

ANCHORS IN CONCRETE

TORQUE LOAD (FT-LBS) TENSION LOAD (LBS)

ANCHORS IN MASONRY

TORQUE LOAD (FT-LBS)

300

1,000

500

1,250 55

35

10

30

1,700 120

1. EXPANSION OR WEDGE ANCHORS INTO CONCRETE: HILTI KB TZ (ICC ESSR-1917) OR SIMPSON STRONG BOLT (ICC ESR-1771) TOBE INSTALLED IN ACCORDANCE WITH ICC REPORT AND MANUFACTURER'S RECOMMENDATIONS.

2. EXPANSION OR WEDGE ANCHORS INTO MASONRY: HILTI KB 3 (ICC ESR-1385) OR SIMPSON WEDGE-ALL (ICC ESR-1396) TO BEINSTALLED IN ACCORDANCE WITH ICC REPORT AND MANUFACTURER'S RECOMMENDATIONS.

3. UNDERCUT ANCHORS INTO CONCRETE: HILTI HDA (ICC ESR-1546) TO BE INSTALLED IN ACCORDANCE WITH ICC REPORT ANDMANUFACTURER'S RECOMMENDATIONS.

4. HEAVY DUTY SLEEVE ANCHORS INTO CONCRETE: HILTI HSL-3 (ICC ESR-1545) TO BE INSTALLED IN ACCORDANCE WITH ICCREPORT AND MANUFACTURER'S RECOMMENDATIONS.

5. FASTENERS SHALL BE STAINLESS STEEL FOR EXTERIOR USE OR WHEN EXPOSED TO WEATHER. PROVIDE GALVANIZED CARBONSTEEL ANCHORS AT OTHER LOCATIONS, UNLESS OTHERWISE NOTED.

6. IF REINFORCEMENT IS ENCOUNTERED DURING DRILLING, ABANDON AND SHIFT THE HOLE LOCATION TO AVOID THEREINFORCEMENT. PROVIDE A MINIMUM OF 2 ANCHOR DIAMETERS OR 1 INCH, WHICHEVER IS LARGER, OF SOUND CONCRETEBETWEEN THE DOWEL AND THE ABANDONED HOLE. FILL THE ABANDONED HOLE WITH NON-SHRINK GROUT. IF THE ANCHOR ORDOWEL MAY NOT BE SHIFTED AS NOTED ABOVE, THE STRUCTURAL ENGINEER WILL DETERMINE A NEW LOCATION.

7. LOCATE REINFORCEMENT AND CONFIRM FINAL ANCHOR LOCATIONS PRIOR TO FABRICATING PLATES, MEMBERS, OR OTHERSTEEL ASSEMBLIES ATTACHED WITH MECHANICAL ANCHORS.

8. ANCHORS SHALL BE PROOF-TESTED BY OWNER'S TESTING AND INSPECTION AGENCY.

9. TEST ANCHORS NO SOONER THAN 24 HOURS AFTER INSTALLATION.

10. APPLY TEST LOAD BY ANY METHOD THAT WILL EFFECTIVELY MEASURE THE TENSION OF THE ANCHOR SUCH AS DIRECT PULLWITH A HYDRAULIC JACK, TORQUE WRENCH, OR CALIBRATED SPRING LOADING DEVICES, ETC.

11. REACTION LOADS FROM TEST FIXTURES MAY BE APPLIED CLOSE TO THE ANCHOR BEING TESTED, PROVIDED THE ANCHOR ISNOT RESTRAINED FROM WITHDRAWING BY A BASE PLATE OR OTHER FIXTURE. IF RESTRAINT IS FOUND, LOOSEN AND SHIM ORREMOVE THE FIXTURE PRIOR TO TESTING.

12. UNLESS OTHERWISE NOTED, PROVIDE MINIMUM EMBEDMENT OF ANCHORS AS SHOWN IN TABLES BELOW.

13.

14. IF ANY ANCHOR FAILS TESTING, REPLACE ANCHOR AND TEST ADDITIONAL ANCHORS OF THE SAME CATEGORY NOTPREVIOUSLY TESTED UNTIL TWENTY (20) CONSECUTIVE TESTS PASS, THEN RESUME INITIAL TESTING FREQUENCY.

A.

B. TORQUE WRENCH METHOD: TEST ANCHORS TO THE TORQUE LOAD INDICATED IN THE TABLE WITH ONE-HALF TURN OF THENUT.

HYDRAULIC RAM METHOD: APPLY PROOF TEST LOAD WITHOUT REMOVING THE NUT. IF IT IS NOT POSSIBLE TO TEST WITHTHE NUT INSTALLED, REPLACE THE NUT WITH A THREADED COUPLER TO THE LOAD. ANCHOR IS ACCEPTABLE IF NOMOVEMENT IS OBSERVED AT THE TEST LOAD. MOVEMENT MAY BE DETERMINED WHEN THE WASHER UNDER THE NUTBECOMES LOOSE.

TEST 50% OF ANCHORS PER ONE OF THE FOLLOWING METHODS AND IN ACCORDANCE WITH THE VALUES SHOWN IN THE TABLE:

U.V. CONTROLPANEL

(N) DIVE POOL5

2MR.4

2MR.3

1-3MR.5

7-8MR.4

2MR.4

2MR.3

1-3MR.5

5MR.3

BV

BFV

=

= BUTTERFLY VALVE

BALL VALVE

CV = CHECK VALVE

CHLORINE INJECTION=

PIPE HANGERPH =

VACUUM / PRESSURE GAUGEPG/VG

C

1MR.6

(E) PNL 'P4'

(E) PNL 'P3'

(E) PNL 'P2'

(E) PNL 'P1'

(E) PNL 'L'

(E) LIGHTING RELAY

(N) CHLORINESTORAGE FEEDSYSTEM 7

CO2 FEEDSYSTEM 6

CO2 FEEDSYSTEM

(N) 6'' x 5'' STRAINER 1

DIVE POOL / LAP POOL CARBON DIOXIDE STORAGE FEED SYSTEMS: PROVIDE TWO (2) 'NOVO-600', 600lb.CRYOGENIC LIQUID CO2 STORAGE TANK WITH REMOTE FILL PORT. 594 LIQUID lbs., (5,195 CUBIC FEET OF GASEOUSCO2 AT NTP) ONE (1) TOTAL. PROVIDE EKO PH-MTS CO2 HIGH EFFICIENCY FEED SYSTEM WITH ALKALINITY CONTROL,0 TO 160 SCFH FEED CAPACITY BOOSTER PUMP, PIPING INJECTOR, FLOWMETER, RELAYS AND ACID FEED ALKALINITYCONTROL. TWO (2) SYSTEMS TOTAL (92lbs. EA.) PROVIDE HARD WIRED 'BRK' #SL177 CO2 DETECTOR WITH AUDIBLEAND VISUAL ALARMS IN EACH CHEMICAL ROOM, UL 1971 STANDARD LISTED, TWO (2) TOTAL.

6

(N) DIVE POOL / LAP POOL FILTERS: 'EPD-S206' AUTOMATIC FILTER CONTROL (AFC) FULLY AUTOMATICHI-RATE PERMANENT MEDIA FILTER WITH 33 SQ. FT. OF FILTER AREA RATED AT 495 GPM AT 15 GPM/SQ. FT.COMPLETE WITH 6'' FACE PIPING, 4'' BACKWASH, SEISMIC ANCHORAGE. PROVIDE ALL UTILITIES, PIPING,VALVING ETC. (4,980 lbs EACH TANK) 'EPD' OR EQUAL. PROVIDE SIGNET MK-515 FLOSENSOR WITH DIGITALREAD-OUT. TWO (2) SYSTEMS TOTAL.

42

MR.62

MR.41

MR.3

3

4

4

(N) 4'' HOUSEKEEP PAD

(N) 4'' HOUSEKEEP PAD 2

3

6 6(N) 600lb CO2STORAGE

6

6MR.3

7-9MR.3

6MR.4

1-2MR.34

(E)

(N)

=

= NEW

EXISTING

=

3MR.6

(N) 6'' x 5'' STRAINER1

AutoCAD SHX Text
1
AutoCAD SHX Text
MECHANICAL ROOM LAYOUT PLAN
AutoCAD SHX Text
;1750 RPM 460V, 3PH; 7\HP; RATED AT 240 GPM @ 70 FT. TDH; 76% EFFICIENT; PREMIMUM ; 7\HP; RATED AT 240 GPM @ 70 FT. TDH; 76% EFFICIENT; PREMIMUM ; RATED AT 240 GPM @ 70 FT. TDH; 76% EFFICIENT; PREMIMUM ; 76% EFFICIENT; PREMIMUM ; PREMIMUM ; EPOXY COAT ALL WET SURFACES. TWO (2) TOTAL. 'PACO', 'AURORA' OR EQUAL.
AutoCAD SHX Text
EQUIPMENT LIST
AutoCAD SHX Text
THREE PHASE MOTOR LOADS AT 460V
AutoCAD SHX Text
WEDGE OR EXPANSION ANCHOR EMBEDMENT DEPTH AND TEST LOAD
AutoCAD SHX Text
MECHANICAL ANCHORAGE
AutoCAD SHX Text
PH
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
Ι
AutoCAD SHX Text
HOLE IN CHAMBER WALL
AutoCAD SHX Text
MOUNTED OVER 30
AutoCAD SHX Text
UV PROBE HOUSING
Page 3: NAL OSI4 SE 0 F 2 ORPD y E Ma ERTSIGER

SIDE ELEVATION

42.0''

FRONT ELEVATIONFOUR (4)-\''~ x 3|'' MIN. EMBED.STAINLESS STEEL HILTI KB TZ

INSPECTION REQUIRED

3|''

46.6

26.8''

29.5''

FLOOR

4,980 lbs. EA.

FOUR (4)-\''~ x 3|'' MIN. EMBED.STAINLESS STEEL HILTI KB TZ

SPECIAL INSPECTION REQUIRED EXPANSION ANCHORS

(ICC ESR-1917)

3|'' 3|

''TY

P.

(E) CONC.

(ICC ESR-1917)

EXPANSION ANCHORS SPECIAL

FLOOR(E) CONC.

NO SCALE NO SCALE

12''PER PUMP

POST-SET CONDITION

(E) PUMP PAD

(E) SLAB REINF.

SS HILTI KB-TZ SPECIAL INSPECTIONREQUIRED (INSTALL PER ICC ESR-1917)

NOTE:PROVIDE BONDING PERCODE.

(300 lbs.)

41''

1\''=1'-0''

SYSTEM PLAN

13|''x19"x{'' PVC TANK BASE W/ 4 FASTENERS12" SCH.40 PVC PIPE SOLUTION TK. BODY x ;15{'' LG.

CHLORINATOR/TANK INFLUENT PIPING

29

2322

21

1920

BOOSTER PUMP PIPING

HAYWARD 1 H.P., PAPP100, CHLORINE BOOSTER PUMP

SPEARS SCH 40 PVC 1 1/2" SLIP X SLIP 45^ ELBOW

221

17*18

5432

1

13|'' DIA. x {'' PVC DIVIDER PLATE

['' SCH. 40 PVC PIPE 2 PCS

1

111

19\'' x 22'' ALUMINUM 1\'' ANGLE FRAME WITH

1

1

PowerBase1030

2['' BLUE & WHITE FLOWMETER MODEL F-44750LH-121['' MILLER TANK MOUNT FLOAT VALVE W/ 4" BALL FLOAT1SPEARS SCH. 40 PVC ['' STREET ELBOW1

SPEARS SCH. 40 PVC 1\'' SLIP X MALE SLIP STREET ELBOWSPA-RITE PVC PUMP UNION HALF

SPEARS SCH. 40 PVC 1\'' x 1'' REDUCING BUSHING130

1 SPEARS SCH. 40 PVC 1\'' SLIP X THREAD 90^ ELBOW

31* 1 1'' KBI PVC GATE VALVE32 2 |'' NPT. x {'' COMPRESSION SPEED FITTING33 1 {'' x |'' AIR VENT TUBING (;16" LG.)34 1 \'' x |'' THD. X THD. PVC BUSHIING35 1 |'' NPT. x \'' BARB 90^ ELBOW

1 SPEARS SCH. 40 PVC 1'' x ['' MALE ADAPTOR

1

EFFLUENT

INFLUENT

INFLUENT

EFFLUENT

ELECTRICAL PANEL & MOTOR BRACKETS & ANCHOR ANGLES

6 17 18 19 110 STACKING CARTRIDGE111 1

ELECTRICAL CONTROL PANEL W/ 4 BOLTS, WASHERS & NUTS1;8FT ELECTRICAL CORD WITH 3-PRONG PLUG2

10'' SCH.40 PVC PIPE CHLORINATOR TK. BODY X ;17\''LG.6'' SCH.40 PVC PIPE SIEVE PLATE SUPPORT x ;3_"LG.

2'' SCH.40 PVC PIPE DIVERTER X ;2"LG.

11|'' DIA. x {'' PVC CHLORINATOR LID PLATE

1213

ELECTRICAL CONDUIT WITH (2) CONNECTORS114

SPEARS SCH. 40 PVC ['' THD. x TRD. 90^ ELBOW15*

1

16*

SPEARS SCH. 40 PVC ['' SLIP X SLIP 90^ ELBOW

SPEARS SCH. 40 PVC 1\'' MALE ADAPTOR1\'' SCH. 40 PVC PIPE (;10" TOTAL)AR

1 2

2

3

4

6

78

11

12

13

14

3

4 68

11

13

12

14

2425262728

16

15 16

17

18

20

22

23

2625

24

27

28

23 24

24

2526

27

28

2632

29

31

32

34

33

35

3234 32

31

2726

1921 1'' SCH. 40 PVC THD OVERFLOW DRAIN PLUG1

1

30

NOTE * = SHIPS LOOSE

CHLORINATORCHLORINATOR

SYSTEMACCU-TAB

36 2 LEVEL SWITCHES

36

36

11B 2 LOCKING TABS

11B

['' SPIRAL SIEVE PLATE

5

5

37 AR 1'' PVC SCH. 40 PIPE

37

38 2 ['' THREAD x BARB PVC ELBOWS39 AR ['' CLEAR TUBING

3938

3938

38

1" SPEARS FLAP CHECK VALVE

25''

19_

''

25''

11B

24

33

109

11B 11B

16

17

15

25''

35|'

'

SYSTEM ELEVATION

\'' SS HILTI KB-TZ WITH3|'' MIN. EMBED(INSTALL PER ESRIOC-1917) FOUR (4)TOTAL.

\'' SS HILTI KB-TZ WITH 3|'' MIN. EMBED (INSTALLPER ESR IOC-1917) FOUR (4) TOTAL.

MAIN CIRC. LINES

WASTE LINE

PIPING (TREATMENT)

TUBING

24V. CABLE115/230V. CABLE

BALANCETANK

DRAIN

115V POWER SUPPLY(SEE WIRING DIAGRAM)

WATER CHEMISTRYCONTROLLER

115/230 VOLTSERVICE DISCONNECT

CHLORINEINJECTIONPOINT

FILTERS

TO WASTE

SUCTION

OPTION: MAY BE DISCHARGEDINTO MAIN CIRCULATION PUMP

SUCTIONPUMP

RETURN

CHECKVALVE

GATEVALVE

SOLENOIDVALVE

GATEVALVE

FLOWMETER

1\HP OR[HP

BALL VALVE

BALL VALVE

2''

2''

INTERCONNECT

NOTE: SWIMMING POOL FLOW RATE = 45 GPMONE (1) SYSTEM.

NO SCALE

BFV

BFV

ETS EZ UV STRAINERSIZED PER BYPASSLOOP DIAMETER

UV DISINFECTION UNITW/ FLANGED CONNECTIONS

{''~ STAINLESS STEEL HILTI KB-TZ WITH 2\'' MIN.EMBED ( CC ESR-1917) THROUGH ANGLE WITH TWOHIGH STRENGTH WASHERS FOUR (4) TOTAL.(92lbs). INTO NEW 4'' CONCRETE PAD

NORMALLY CLOSEDUV BYPASS LOOP

\'' DRAIN DOWNPLUG FOR U.V.SERVICING

U.V. BYPASSTEE RETURN LINE

PER PLAN

U.V. BYPASSTEE

ISOLATIONBFVISOLATION

PIPINGPER PLAN

DETAILS

MR.3

c w

oofter architecture 2018

wo

ofte

r a

rc

hite

ctu

re

107 S

E W

ashington S

treet, S

uite 228

Portland, O

R 97214

503 724 0111

Revisions

Project No.

Date

OSU

DR

C A

QU

ATI

CS

IMPR

OV

EMEN

TS6

44

S

W 1

3T

H A

VE

NU

E,

CO

RV

AL

LIS

, O

R 9

73

33

OR

EG

ON

ST

AT

EU

NIV

ER

SIT

Y6

44

S

W 1

3th

A

VE

NU

E

CO

RV

AL

LIS

, O

R 9

73

33

01/07/20

07601

RE

NE

IN

EG

LAN

EISS

O

R

O

PF

DR

EGSI

T

R

EE 74

816P

E

OR

EG

ON

Ma

y11

,0

204

DOU

GL A

SE

FE

RLL

R

EX

PIR

ATI

ON

DA

TE:

CONTROL PANEL

REACTION CHAMBER

JUNCTIONBOX

7 FT.CABLE LENGTH

SEE NOTE #1

NOTES:

1. STANDARD CABLE LENGTH FROM REACTION CHAMBER TO CONTROL PANEL IS 16 FEET.

2. SEE SPECIFICATIONS FOR BARRIER M UNIT, CONTROL PANEL, AND JUNCTION BOX DIMENSIONS.

OPTIONAL CABLE LENGTHS AVAILABLE IN 33 FT, 66 FT, AND 164 FT.

NO SCALE

(240 lbs.)

FLOOR(E) CONC.

NO SCALE

REAR VIEW

CO CONNECTION

50' TRANSFORMER

SIDE VIEW

2

2\''

CONTROLLERpH MTS

PLAN VIEW

13[''

14|''

9[''

5|''

CORD

6''

13\''

21''

24[

''

1\'' PVC PIPE

5\''

1\'' FIPS

6{''

48\''

4''5''

CHEMICAL CONTROLLERPLUG CORD INTO

TRANSFORMER

7 5/16''[''

7 5/

16''

6['' SIDE

{''~ STAINLESS STEELHILTI KB-TZ WITH 2'' MIN.EMBED ( CC ESR-1917)THROUGH ANGLE WITHTWO HIGH STRENGTHWASHERS FOUR (4)TOTAL. (92lbs).

TRANSFORMERCABLECONNECTION

POWER SUPPLY115/230 VAC1-PH, 60HZ 20AMP [HPBOOSTER PUMP

NO SCALE

MAIN CIRC. LINES

WASTE LINE

PIPING (TREATMENT)

TUBING

24V. CABLE115/230V. CABLE

BALANCETANK

DRAIN

SUPPLY(SEE WIRING

WATER CHEMISTRYCONTROLLER

115V

TRANSFORMER

24V

pH-MTS SYSTEM

SUCTION

OPTION: MAY BE DISCHARGEDINTO MAIN CIRCULATION PUMP

SUCTIONPUMP

RETURN

DIAGRAM)

115V POWER

115/230 VOLTSERVICEDISCONNECTCHLORINEINJECTIONPOINT

CO2STORAGETANK

CO2 INJ.PT. GPMFLOWSENSOR

FILTERSTO WASTE

26''

FRONT ELEVATION

PLAN VIEW

ISOMETRIC VIEW

955 lbS.

70\''

NO SCALE

FLOOR(E) CONC.

AutoCAD SHX Text
1
AutoCAD SHX Text
FILTER ANCHORAGE
AutoCAD SHX Text
2
AutoCAD SHX Text
PUMP ANCHORAGE
AutoCAD SHX Text
FOUR (4)-\''~ x 3|'' MIN. EMBED.
AutoCAD SHX Text
ACCU-TAB POWERBASE 1030 CHLORINATION SYSTEM
AutoCAD SHX Text
QUAN.
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
BILL OF MATERIAL
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
GPM
AutoCAD SHX Text
LPM
AutoCAD SHX Text
3
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
PPG POWERBASE AT INSTALLATION
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
ECF U.V. DISINFECTION UNIT INSTALATION DETAIL
AutoCAD SHX Text
ANSI 12" CLASS-150 (RF) FLANGE
AutoCAD SHX Text
ANSI 12" CLASS-150 (RF) FLANGE
AutoCAD SHX Text
ICC ESR-1917) THROUGH ANGLE WITH TWO
AutoCAD SHX Text
U.V. DISINFECTION UNIT TYPICAL INSTALLATION
AutoCAD SHX Text
9
AutoCAD SHX Text
CARBON DIOXIDE pH MTS CONTROLLER
AutoCAD SHX Text
ICC ESR-1917)
AutoCAD SHX Text
TYPICAL CARBON DIOXIDE pH-MTS INSTALLATION
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
\''~ x 3|'' MIN. EMBED. THREE (3) TOTAL. SS HILTI KB TZ SPECIAL INSPECTION REQUIRED (ICC ESR-1917)
AutoCAD SHX Text
28''~
AutoCAD SHX Text
<
AutoCAD SHX Text
<
AutoCAD SHX Text
CO2 TANK ANCHORAGE DETAIL
Page 4: NAL OSI4 SE 0 F 2 ORPD y E Ma ERTSIGER

DETAILS

MR.4

c w

oofter architecture 2018

wo

ofte

r a

rc

hite

ctu

re

107 S

E W

ashington S

treet, S

uite 228

Portland, O

R 97214

503 724 0111

Revisions

Project No.

Date

OSU

DR

C A

QU

ATI

CS

IMPR

OV

EMEN

TS6

44

S

W 1

3T

H A

VE

NU

E,

CO

RV

AL

LIS

, O

R 9

73

33

OR

EG

ON

ST

AT

EU

NIV

ER

SIT

Y6

44

S

W 1

3th

A

VE

NU

E

CO

RV

AL

LIS

, O

R 9

73

33

01/07/20

07601

RE

NE

IN

EG

LAN

EISS

O

R

O

PF

DR

EGSI

T

R

EE 74

816P

E

OR

EG

ON

Ma

y11

,0

204

DOU

GL A

SE

FE

RLL

R

EX

PIR

ATI

ON

DA

TE:

NO SCALE

(E) ELECTRICAL 24 VAC

CONSOLECONTROL

POWER

120 VAC, 20A POOLCONTROLLER RELAY

PANEL

N

120 VAC

24 VAC

CIRC. PUMPMOTOR CONT.

N

CIRC.PUMP

24 VAC

TRANSFORMER

120 VAC

N

120 VAC 24 VACCABLE

CONTROLLER

CHEMICAL FEED RELAYSCONTROL INTERLOCK FOR120 VAC CIRCULATION PUMP

24 VAC

FILTERR' W'

120 VAC

AFC FILTRATION

WITH DEDICATED NEUTRAL

120 VAC, 15ADEDICATED POWER

N

120 VAC

120 VAC120 VAC

N

CONTROLLER

NINSTALL 1 #12 GROUND CONDUCTOR IN ALL CONDUITS

ALL CONDUITS SHALL BE RIGID OR INTERMEDIATE

RESPONSIBLE FOR A FULLY OPERATIONAL SYSTEM.OPERATING INSTRUCTIONS. CONTRACTOR SHALL BEREFER TO FILTER "OWNER'S MANUAL" FOR INSTALLATION/

ALL WORK SHALL BE IN ACCORDANCE WITH LATEST EDITIONOF THE CALIFORNIA ELECTRIC CODE (N.E.C.) FURNISH ALL LABOR,MATERIALS AND COORDINATION OF WORK HERE ON SHOWN/IMPLIED.

4.

N

N

GALVANIZED METAL.2.

3.

NOTES:

1.

24 VAC

WITH HOA AND PILOT LIGHT

CONTROLLERWATER CHEMISTRY LO 0.2 0.4 0.6 0.8 1.0 1.5 2.0 3.0 HI

Alarm

Cal

Set

Point

pH Feed

Cl/Br Feed

Failsafe

pH 7.5HRR 755Cl2/Br2 (ppm)

TEMP 85°F

SEE DETAIL 6/MR-4

(E) HEAT EXCHANGER

ACCU-TABCHLORINATION CO2 ACID ASSIST

SYSTEMSYSTEM

1\''=1'-0''

13]''

9|''

16{

''

27''

20[

''

SIDE VIEWFRONT VIEW

16116''

141516''

5916''

1\''=1'-0''

10''

6\''

7 1/16''

9 7/

16''

SIDE VIEWFRONT VIEW

4{''

NO SCALE

BALL TYPE PVCCHECK VALVE

TO SUCTION SIDE OF PUMPCONTROLLER SAMPLE RETURN

PVC BALL VALVE

UNIT PERSPEC'S

WIRING TOWALL UNIT

PVC BALL VALVE

& BEFORE HEATER

MAIN WALL

CONTROLLERSAMPLE TAKENAFTER FILTER

CONTROL

\" CONTROLLER LINE

UNION

HOSEBIBB

POOL WATERCHEMISTRYCONTROLLER

ELECTRODE

PER SPEC'S

REMOTE

HOUSING

UNION

\''C2-#12,

MOUNTED ATFEED PUMP

+60'' A.F.F.

WATERCHEMISTRY

CONTROLLER

NOTES:

VARIABLE SPEED DRIVE MOTOR CONTROL CABINET, SEE PLANS AND SPECIFICATIONS.

VARIABLESPEED

MD

1

ENCLOSED CIRCUIT BREAKER, SEE SINGLE LINE DIAGRAM.2WATER CHEMISTRY/FILTER CONTROL UNIT, SEE PLANS.3CONNECT TO CIRCULATION PUMP MOTOR, SEE PLANS.4MOTOR FEEDERS, SEESINGLE LINE DIAGRAM.5120 VOLT BRANCH CIRCUITS, SEE PLANS.6[''C, (4) #12, (1) #12 GND. (120 VOLT CONTROL WIRING)724 VOLT SIGNAL AND SENSOR CABLING, SEE SPECIFICATIONS AND8INSTALLATION INSTRUCTIONS FOR ADDITIONAL REQUIREMENTS.

6

3 1

7

8

5

5

4DRIVE

ELEC. PANELTO (E) 120/208V

MOTOR DISCONNECT, SEE PLANS.9

CB2

9

6

15 HP

NO SCALE

7\ HP

ELEC. PANELTO (E) 120/208V

ACONDUIT ENTRY - TOP VIEW

1'' DIA

CONDUIT ENTRY - BOTTOM VIEW

FOR 1\'', 2'', AND2\'' CONDUIT

FRONT VIEW

SIDE VIEW

VENTS IN TYPE 1 ONLY

B

C

D

E ]'' DIA

{'' DIA

J

ANCHORS WITH 2\'' EMBED TO

K

I

HG

F

AUTO AFC RUN FAULT POWER ON

NOTE:PROVIDE AT LEAST 3'' OF MOUNTING CLEARANCE ON EACH SIDE OF THE DRIVE CONTROLLER.PROVIDE AT LEAST 6'' OF MOUNTING CLEARANCE ON EACH TOP AND BOTTOM OF THE DRIVE CONTROLLER

FOR \'', ['', AND1'' CONDUIT

FOR 1\'', 2'', AND2\'' CONDUIT

FOR \'', ['', AND1'' CONDUIT

NO SCALE

4-{'' SS HILTI KB 3

CONCRETE WALL (ESR-1385)

177 lbs.

208/230V

HP

460V

HP

LBS

WEIGHT

A

DIMENSIONS

B C D E F G H I J K

7.5 TO 1010 TO 25 20.00'' 13.93'' 12.08'' 3.01'' 38.38'' 19.49'' 17.54''126 7.65'' 41.00'' 39.75''1.86''

COMMON NAME CHEMICAL NAME CAS # FORM JUSTIFICATION%COMP.

QUANT.STORED

(NOT USED)

QUANT. IN USE(USE-CLOSED)

LOCATION(STORAGE &

USE)HAZ.

CLASSES

CHEMICAL CLASSIFICATION TABLEMAXIMUM

ALLOWABLEQUANTITY

65% 7778-54-3 TABLET 45 lbs. MECH. ROOM MSDSCALCIUMHYPOCHLORITE

CALCIUMHYPOCHLORITE 150 lbs. OXIDIZER1,150 lbs.

BLUE

WHITE

RED

YELLOW

REACTIVITYHAZARD

SPECIFICHAZARD

FLAMMABILITYHAZARD

HEALTHHAZARD

LEGEND

CALCIUM HYPOCHLORITE

RATING EXPLANATION GUIDERATING HEALTH HAZARD FLAMMABILITY HAZARD REACTIVITY HAZARD

CAN BE LETHAL MAY EXPLODE AT NORMALTEMPERATURES ANDPRESSURES

MAY EXPLODE AT HIGHTEMPERATURES OR SHOCK

IGNITES AT ABOVE 73° F, BELOW100° F.

CAN CAUSE SERIOUS ORPERMANENT INJURY

EXTREMELY FLAMMABLE.IGNITES AT BELOW 73° F.

VIOLENT CHEMICAL CHANGE ATHIGH TEMPERATURES ORPRESSURES

CAN CAUSE TEMPORARYINCAPACITATION OR RESIDUALINJURY

NORMALLY STABLE. HIGHTEMPERATURES MAKEUNSTABLE

CAN CAUSE SIGNIFICANTIRRITATION

IGNITES AT ABOVE 200° F.

IGNITES AT ABOVE 100° F,BELOW 200° F.

STABLEWILL NOT BURNNO HAZARD

4

3

2

1

0

SPECIFIC HAZARD

OXIDIZER:

ACID:

CORROSIVE:

ALKALI:

USE NO WATER:

RADIATION HAZARDS:

POLYMERIZES:

OX

ACID

COR

ALK

W

P

NOTES:1.

2.

CONFIRM SIGNAGE WITH LOCAL FIRE MARSHALL AND/OR BUILDING CODES PRIOR TO INSTALLATION. SIGNS SHALL

SIGNS SHALL BE SIZES AND COLORS PER CODE MOUNTED AT +60" A.F.F. ON DOORS AT CHEMICAL ROOMS.CONFORM TO NFPA 704.

EXISTING CO2MSDSLOCATION

SEE SHEET MR.2

CARBON DIOXIDE

NO SCALE

1 TO 51 TO 7.5 14.76'' 13.93'' 12.08'' 3.01'' 37.38'' 14.25'' 12.30''83 6.11'' 35.00'' 33.75''1.86''

QUANTITIES OF CHEMICALS DO NOT EXCEED THE QUANTITIES LISTED IN IBC TABLES 307.1 (1) AND 307.1 (2).FOR CARBON DIOXIDE GAS SEE TABLE 1.12.8(b) OF THE NFPA. 6,000 FT3 ALLOWABLE OR 686 lbs. STORAGE PER CONTAINED AREA

CARBON DIOXIDE 100% 124-39-9 LIQUID 0 lbs. 600 lbs. CRYOGENICCARBON DIOXIDE 686 lbs.

PROVIDE HARD WIRED CO2 DETECTOR 'ANALOX SENSOR TECHNOLOGY' MODEL #AP1 KIT SENSOR AND STROBE UNITS 120V HARD WIRED W/ STROBE LIGHT ANDAUDIBLE ALARM. SENSOR MOUNTED 18 INCHES A.F.F. AND ALARM LEVEL BETWEEN 70-76 INCHES AND WITHIN VISIBLE EYESIGHT OF DOOR. TO BE SET TO DETECTCO2 GAS IN LEVELS IN EXCESS OF THE PEL. PROVIDE IN EACH ROOM CONTAINING CO2.

TUBE ADAPTERTYP.

TYP.

\'' SCH. 80

\'' SCH. 80PVC PIPE

PVC FIPFEMALEADAPTER TYP.

TO METERINGPUMP

LMI PRESSURETUBING TYP.

LMI PIPE TO

VALVE (CO2)INJECTION/CHECKTO CHEMICAL

NO SCALE

AT 24'' O.C. MOUNTEDB-LINE #B3191\'' PIPE CLIP

TO WALL

AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
8
AutoCAD SHX Text
POOL MECHANICAL ELECTRICAL INTERCONNECTION DIAGRAM
AutoCAD SHX Text
BECSYS FILTER INTERFACE SYSTEM
AutoCAD SHX Text
BECSYS 5 WATER CHEMISTRY CONTROLLER
AutoCAD SHX Text
WATER CHEMISTRY CONTROLLER SCHEMATIC
AutoCAD SHX Text
TYPICAL WIRING SCHEMATIC AT SPCS UNIT
AutoCAD SHX Text
'SPCS' EKO-FLEX ENCLOSURE DIMENSIONS
AutoCAD SHX Text
'SPCS' EKO-FLEX SIZING TABLE
AutoCAD SHX Text
0
AutoCAD SHX Text
3
AutoCAD SHX Text
1
AutoCAD SHX Text
OX
AutoCAD SHX Text
3
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
HAZARDOUS INFORMATION SIGNAGE
AutoCAD SHX Text
7
AutoCAD SHX Text
CHEMICAL FEED PIPING DETAIL
Page 5: NAL OSI4 SE 0 F 2 ORPD y E Ma ERTSIGER

DETAILS

MR.5

c w

oofter architecture 2018

wo

ofte

r a

rc

hite

ctu

re

107 S

E W

ashington S

treet, S

uite 228

Portland, O

R 97214

503 724 0111

Revisions

Project No.

Date

OSU

DR

C A

QU

ATI

CS

IMPR

OV

EMEN

TS6

44

S

W 1

3T

H A

VE

NU

E,

CO

RV

AL

LIS

, O

R 9

73

33

OR

EG

ON

ST

AT

EU

NIV

ER

SIT

Y6

44

S

W 1

3th

A

VE

NU

E

CO

RV

AL

LIS

, O

R 9

73

33

01/07/20

07601

RE

NE

IN

EG

LAN

EISS

O

R

O

PF

DR

EGSI

T

R

EE 74

816P

E

OR

EG

ON

Ma

y11

,0

204

DOU

GL A

SE

FE

RLL

R

EX

PIR

ATI

ON

DA

TE:

NO SCALE

S3

BECs 4-20mA Output Signal

-

+

(L) (N)BECs RUN COMMAND120V

DIRECT CONNECTIONTO OVERLOAD RELAY (OL1)

T3T2T1

CP

GND

30

FUSED INTERLOCKED CONTACT

N

L3L1 L2

A B C

3 PHASE, 60 Hz

LAP POOLCIRCULATION PUMP15 HP, FLA 21.0460V, 3PH, 60 Hz

25 26

S2+

DIVE POOLCIRCULATION PUMP7\ HP, FLA 11.0460V, 3PH, 60 Hz

MAIN CIRCUIT BREAKER

P1

460 VAC, 3 PHASE, 60 Hz11.0 AMP FOR DIVE POOL

OVERLOAD

LINE REACTOR

LINE CONTACTORBYPASS CONTACTOR

4-20mA Signal

BYPASSOFF

BECSys

120V Pump RunVFDLOGICINPUTS

VFDANALOG

INPUTS

BECSys Control

VFDOUTPUTS

AUTO

A

G

ADJUSTABLE

FREQUENCY

DRIVE

AFD 1

AFC RUN

FAULT

A

R

POWERON

LC

SWIMMING POOL CIRC. PUMP 20 HP, FLA 27.0460V, 3PH, 60HZ

NO SCALE

ACTIVITY POOL CIRC. PUMP 10 HP, FLA 14.0460V, 3PH, 60HZ

460 VAC, 3 PHASE, 60 Hz21.0 AMP FOR LAP POOL

INDOOR POOL CIRC. PUMP 15 HP, FLA 21.0460V, 3PH, 60HZ

NO SCALE

LC13 14

13 14

13 14

8AUTO START

7

96A 6

N

DEVICE TERMINALTERMINL BLOCK (TB)NUMBER - 115 VACLETTER = 10/24 VDC

RUN COMMANDRELAY

AUTOMODE

POWERON

LINECONTACTOR

BYPASSCONTACTOR

BYPASSRUN

AUX DRIVEFAULT RELAY

AFCFAULT

AUX DRIVERUN RELAY

TO MOTOROL

OL

OL

L1

L2

L3

R1A

R1C

R1B

SIGNALFAULTAFC

6AFCRUN

AUTO/MAN

R2A

R2C

6

6

6

AO1 AO1

COM COM

10V

AI1+

AI1-

RUNFWDLI1

FREEWHEELSTOP

LI2

PWR+24

COM

AI2

SPEEDPOT

12

S3

S2+

SS

FAULTRESETLI4

LI3

MODBUSINTEGRATEDRJ45

LI5

LI6

DC SUPPLY

U

V

W

BC

BC

BC

LC

LC

LC

CB

FROMPOWERSUPPLY

BC

LC120V INTERLOCKED CONTACT

AFCRUN

30

10

(H1)

(H3) (H2)(H4)(H1)

(H2)

(X1) (X2)GND

DETAIL A

115V

1T

208V

208V TRANSFORMERCONNECTION

LEGEND

115VX1 X2

XF FU1

460V

2

6

1

FU3

FU2

31 32 32 31

22 21

21 22

83 84

1 2 6 10 E FRPRRCR

D

C C

B

A

A1LC

TEST-NORMAL

HAND-OFF-AUTO

TEST-NORMAL

HAND-OFF-AUTO

L2

L3

L1

T2

T3

T1

OLR

A1 A2

X1 X2

X1 X2

X1 X2

X1 X2

X1 X2

A1 A2

A1 A2

13 14

13 14

23 24

13

13 14

13 14

2 1

3 4

5

13 12 21 22BC

RCR

RCR

ADFR

11 12 11

10A

24RCR

ADFR

ADRR

15 16

5-8 SEC 99 1

R2C R2A

R1C R1A

14 15

95 96

AFCDRIVERUN

AFCDRIVEFAULT

BC

LC

TS

TS

Y

R

Y

G

TS

Y

GNDLINE REACTOR

STIRRING FAN

PUMPS FANS2/3 WIRE CONTROL

STANDARD MOT. FREQ (HZ)ACCELERATION (SEC)DECELERATION (SEC)LOW SPEED (HZ)SWITCHING FREQ. (HZ)2 WIRE TYPEAI2 MIN. VALUE (mA)R2 ASSIGN - DRIVE RUNNING

REF. 1 CHAN

PROFILEFREEWHEEL STOP ASSIGNREF. 1B SWITCHINGREF. 1B CHANFAULT RESETCATCH ON THE FLYOUTPHASE LOSSFORCED LOCAL ASSIGN.

SIM 1.1SIM 1.1SIM 1.1SIM 1.1SIM 1.1SIM 1.1SIM 1.3I - O 1.5I - O 1.5I - O 1.5

CtL 1.6CtL 1.6

CtL 1.6FUn 1.7FUn 1.7FUn 1.7FLt 1.8FLt 1.8FLt 1.8COM 1.9

AI2 CONFIG.R2 CONFIG.

STOP CONFIG.REFERENCE SWITCHREFERENCE SWITCHFAULT RESETCATCH ON THE FLYOUTPUT PHASE LOSSFORCED LOCAL

ADJ.MENU No SUB-MENU DESCRIPTION

EKO-FLEX ATV61 FACTORY CONFIGURATION

CODE

tCC 2CCFGbFrACCdECLSPSCrtCtCrl2r2C

FR1FR1

CHCFnSTrCbFr1brSFFLRPDLFLt

PnF60101038

LEL4

rUn

HMIAI1

SEPLI2LI3AI2LI4YESNOLI4

DESCRIPTION

STIRRING FANS

VENTILIATION FAN

SPACE HEATER NA

NA

7.5-50HP 208/230V10-100 HP 460V,

ALL HP

ALL HP

NA

TYPE 3RTYPE 12KTYPE 1

NA

NA

7.5-50HP 208/230V10-100 HP 460V,

BECs RUN COMMAND RELAY (BRCR)8

9 JUMPER USED WHEN START-STOP PUSH BUTTONS NOT USED.

RCR TIMED CONTACT USED ONLY IF LINE CONTACTOR IS SUPPLIED

CONTROL TRANSFORMER SHOWN FOR 460V PRIMARY. FOR 230V PRIMARY, JUMPER H2-H3 IS

PROGRAMMED I/O SEE CONTROLLER FUNCTION CONFIGURATION TABLE.

2

1

6

NOTES:

67SS2+S3

123

2223

161718192021

242526

11

14

L

N

ADFR

ADFR

ADRR

ADRR

30N

AFC AUXILIARY RUN CONTACT(SHOWN NOT RUNNING)

AFC AUXILIARY RUN CONTACT(SHOWN IN FAULT MODE)

;4 - 20mA Signal from BCESys

120V RUN COMMAND FROM BCESys

120V INTERLOCKED CONTACT

USER CONNECTIONS

AutoCAD SHX Text
3
AutoCAD SHX Text
1
AutoCAD SHX Text
'SPCS' EKO-FLEX FIELD CONNECTION DIAGRAM
AutoCAD SHX Text
'SPCS' EKO-FLEX SINGLE LINE DIAGRAM
AutoCAD SHX Text
'SPCS' EKO-FLEX VARIABLE FREQUENCY DRIVE SYSTEM SCHEMATIC
AutoCAD SHX Text
AFC
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
4
AutoCAD SHX Text
8
AutoCAD SHX Text
12
AutoCAD SHX Text
3A
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
9
AutoCAD SHX Text
6
AutoCAD SHX Text
OFF
AutoCAD SHX Text
AFC
AutoCAD SHX Text
BYP
AutoCAD SHX Text
ADFR
AutoCAD SHX Text
ADRR
AutoCAD SHX Text
BRCR
AutoCAD SHX Text
BRCR
AutoCAD SHX Text
2
Page 6: NAL OSI4 SE 0 F 2 ORPD y E Ma ERTSIGER

DETAILS

MR.6

c w

oofter architecture 2018

wo

ofte

r a

rc

hite

ctu

re

107 S

E W

ashington S

treet, S

uite 228

Portland, O

R 97214

503 724 0111

Revisions

Project No.

Date

OSU

DR

C A

QU

ATI

CS

IMPR

OV

EMEN

TS6

44

S

W 1

3T

H A

VE

NU

E,

CO

RV

AL

LIS

, O

R 9

73

33

OR

EG

ON

ST

AT

EU

NIV

ER

SIT

Y6

44

S

W 1

3th

A

VE

NU

E

CO

RV

AL

LIS

, O

R 9

73

33

01/07/20

07601

RE

NE

IN

EG

LAN

EISS

O

R

O

PF

DR

EGSI

T

R

EE 74

816P

E

OR

EG

ON

Ma

y11

,0

204

DOU

GL A

SE

FE

RLL

R

EX

PIR

ATI

ON

DA

TE:

-20

-30

60

-10

0

20

10

50

30

40

Hg

psi

SNUBBER

'PETCOCK' MODEL #A10, BRASS

4\'' S/S CASED LIQUID FILLEDPRESSURE GAUGES SHALL HAVE A DIALRANGE PRESSURE OF 60psi ANDVACUUM RANGE OF 30'' Hg THE MINORGRADUATIONS SHALL HAVE APRESSURE OF 2psi AND VACUUM OF 2''Hg, |'' NPT PER SPECIFICATIONS.

1.

2.

NOTES:PRESSURE GAUGES SHALL BE INSTALLEDBY MEANS OF DRILLING AND TAPPINGPIPE TO BE MONITORED. THE GAUGESHALL THEN BE THREADED INTO THEPIPE. PROVIDE WITH SNUBBER AND PETCOCK.

GAUGE MAY BE USED WHEREVERCRUCIAL VACUUM OR PRESSUREREADINGS ARE ESSENTIAL.

6''=1'-0'' NO SCALE

VAR

IES

1|'' NPSMTHREADEDCAP

SENSOR BALE

1.05''

SEE

TAB

LE 'A

'

-45^ +45^

0^

DRILL HOLEPER TABLE'A'

SENSORCAP

BLACKCONDUITCAP

SENSORBALE

TAB

NOTCH

10x PIPE DIA.

OUTLETINLET FLOW

MANUAL FILTER = 'SIGNET' 3-5090AUTOMATIC FILTER = FILTER CONTROLLER

FLOW DISPLAY

NOTES:HORIZONTAL PIPE RUNS: MOUNT SENSOR IN -45^, 0^,OR +45^ POSITION PER MANUFACTURER'SRECOMMENDATIONS.

1.

VERTICAL PIPE RUNS: MOUNT SENSOR IN ANYORIENTATION PER MANUFACTURER'SRECOMMENDATIONS.

2.

SECTION 'A'

FLOW SENSOR LOCATION PER PLAN3.

A

ASIGNET 515 STANDARD

PIPE DIA.

\'' THRU 4''5'' THRU 8''

FLOWSENSORLENGTH

4.1''

10'' AND UP5.4''8.4''

SIGNET 515 - TABLE 'A'

DRILLHOLE

2|''2|''

1716''

PIPE DIA. PERTABLE 'A'

IRONSTRAP-ONSADDLE

FLOW SENSOR5x PIPE DIA.

SPACER SLEEVEREQUIRED AROUNDBOLTBRACE TO

4''MAX.

B-LINE B3100 SERIESPIPE HANGER TYP.

HANGER/BRACE PERPENDICULAR HANGER/BRACE LONGITUDINAL

NOTES:1. FOR COPPER TUBING USE COPPER PLATED OR PAINTED B3104CT, FELT LINED B3100F, OR PLASTIC COATED B3100C.

2. PROVIDE BRACING FOR EACH PIPE RUN IN TWO DIRECTIONS.

ROD STIFFENER (MIN. {'' ROD) UNISTRUT #P1000T RODSTIFFENER W/ CLIP SPACINGAT 13'' MAX. O.C. TYP.

MAX. SLOPE (MAYVARY 40^ TO 45^)

(MIN. 1 CLIP AT EACH END)

LATERAL BRACING

P1843W HINGEUNISTRUT

CLAMP

BRACE TOP1843W HINGEUNISTRUT

CLAMP

B-LINE B3100 SERIESPIPE HANGER TYP.

NO SCALE

HANGER ROD SIZES/TABLE}''~ AT 4'' PIPING MAX. ROD LENGTH = 30''[''~ AT 6'' PIPING MAX. ROD LENGTH = 30''

~ AT 12'' PIPING MAX. ROD LENGTH = 30''7/8''

[''~ AT 8'' PIPING MAX. ROD LENGTH = 30''

MAX. PIPE HANGER SPACING4'' PIPING OR SMALLER = 8'-0'' O.C.6'' PIPING = 6'-0'' O.C.

12'' PIPING = 4'-0'' O.C.

8'' PIPING = 6'-0'' O.C.

3. REFER TO MR.1 FOR PIPE HANGER LOCATIONS..

P1000 TRANSVERSEBRACE

BRACING +45^

AutoCAD SHX Text
1
AutoCAD SHX Text
PRESSURE/VACUUM GAUGE
AutoCAD SHX Text
SIGNET FLOWMETER
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
'UNISTRUT' PIPING HANGER / SUPPORT DETAILS