80
Name of Subsation: S.No Item Code. Name of Item Unit Usable Dismantle/Inco mplete/Damage Obsolete Scrap 1 Bolted Type Tension Fitting No. 12 2 Hot Dip Galv. Nuts & Bolts 16X40 mm No. 1989 3 Hot Dip Galv. Nuts & Bolts 16X45 mm No. 2974 4 Hot Dip Galv. Nuts & Bolts 16X50 mm No. 68 5 Hot Dip Galv. Flat Washer16X5 mm No. 860 6 Hot Dip Galv. Flat Washer16X6 mm No. 1974 7 Tension Clamp SWG Earth Wire No. 112 8 ACSR Panther Conductor K.M. 2.526 9 Hot dip Galv. Nuts Bolts 16X90mm No. 70 10 SWG Earth wire 7/10 K.G. 928 11 Copper Bond No. 18 12 Tension fitting for comprection Type for Panther Conductor No 1 13 Repair Sleeve for Panther Conductor No. 3 14 Mid Spen Joint for Panther No. 15 15 ACSR Zebra conductor Mtr. 175.5 16 M.S. Round 36 mm K.G. 385.5 17 120 KN DISC Insulator No. 75 18 70 K.N. Disc Insulator No. 175 19 Bolted Type Tension fitting for Panther No. 13 20 2X2.5 mm sq Control cable Mtr. 28 21 4X2.5 mm sq Control cable (in pieces) Mtr. 1027 22 6X2.5 mm sq Control cable (in pieces) Mtr. 1481 23 10X2.5 mm sq Control cable (in pieces) Mtr. 874 24 High Volts discharged Rod for 132 KV (9 pieces) Set 1 25 Small chain No. 2 26 Big Chain No. 1 27 33 KV Jow No. 2 28 132 KV Jow No. 3 29 Single Suspension fitting No. 3 30 G.J.V. Bolts No. 6 31 33 KV C.T. Clamp for panther No. 5 32 132 KV Isolator Jow of Bimco No. 10 33 C.T 33 KV No. 3 34 Winding Tempreture Meter No. 1 35 5Bolted Tension Fitting For Zebra Conductor No. 6 36 Copper pipe size ID-3/4" dia Isi mark for cascading of two Compresser Mtr. 4 37 Spring Charging Motor as per sample No. 1 38 Digital control panel Ampere Meter AE Make size150x150mm CTR 400/1A No. 2 39 Digital control panel Ampere Meter AE Make size150x150mm CTR 200/1A No. 3 40 Doble Pole MCB 10 Ampere Havells Make No. 3 41 MCB Box with clamp for fixing on Gantry Havells Make No. 4 42 Tripple Pole MCB 16Amp. Hawells make No. 4 43 ACSR Weasel Conductor Mtr. 1500 44 GI Stay Set No. 5 45 Contractor NONC,Volt Coil 110V -125V,DC 25Amp,3No+3NC TC make No. 3 46 3Bolted PG clamp Z/P made Alluminium alloy No. 6 47 MCB Single Pole Havells make 16 Amp. No. 7 48 Non Retirn Valve for Elge Comperssor No. 1 132KV Substation Almora

Upload: others

Post on 23-Apr-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

Name of Subsation:

S.No Item Code. Name of Item Unit Usable Dismantle/Inco

mplete/Damage

Obsolete Scrap

1 Bolted Type Tension Fitting No. 122 Hot Dip Galv. Nuts & Bolts 16X40 mm No. 19893 Hot Dip Galv. Nuts & Bolts 16X45 mm No. 29744 Hot Dip Galv. Nuts & Bolts 16X50 mm No. 685 Hot Dip Galv. Flat Washer16X5 mm No. 8606 Hot Dip Galv. Flat Washer16X6 mm No. 19747 Tension Clamp SWG Earth Wire No. 1128 ACSR Panther Conductor K.M. 2.5269 Hot dip Galv. Nuts Bolts 16X90mm No. 70

10 SWG Earth wire 7/10 K.G. 92811 Copper Bond No. 18

12Tension fitting for comprection Type for

Panther Conductor No 1

13 Repair Sleeve for Panther Conductor No. 314 Mid Spen Joint for Panther No. 1515 ACSR Zebra conductor Mtr. 175.516 M.S. Round 36 mm K.G. 385.517 120 KN DISC Insulator No. 7518 70 K.N. Disc Insulator No. 17519 Bolted Type Tension fitting for Panther No. 1320 2X2.5 mm sq Control cable Mtr. 2821 4X2.5 mm sq Control cable (in pieces) Mtr. 102722 6X2.5 mm sq Control cable (in pieces) Mtr. 148123 10X2.5 mm sq Control cable (in pieces) Mtr. 874

24High Volts discharged Rod for 132 KV (9

pieces) Set 1

25 Small chain No. 226 Big Chain No. 127 33 KV Jow No. 228 132 KV Jow No. 329 Single Suspension fitting No. 330 G.J.V. Bolts No. 631 33 KV C.T. Clamp for panther No. 532 132 KV Isolator Jow of Bimco No. 1033 C.T 33 KV No. 334 Winding Tempreture Meter No. 1

355Bolted Tension Fitting For Zebra Conductor No.

6

36Copper pipe size ID-3/4" dia Isi mark for

cascading of two CompresserMtr. 4

37 Spring Charging Motor as per sample No. 1

38Digital control panel Ampere Meter AE Make

size150x150mm CTR 400/1ANo. 2

39Digital control panel Ampere Meter AE Make

size150x150mm CTR 200/1ANo. 3

40Doble Pole MCB 10 Ampere Havells Make No.

3

41MCB Box with clamp for fixing on Gantry

Havells MakeNo. 4

42 Tripple Pole MCB 16Amp. Hawells make No. 443 ACSR Weasel Conductor Mtr. 150044 GI Stay Set No. 5

45Contractor NONC,Volt Coil 110V -125V,DC

25Amp,3No+3NC TC makeNo. 3

463Bolted PG clamp Z/P made Alluminium alloy

No. 6

47 MCB Single Pole Havells make 16 Amp. No. 748 Non Retirn Valve for Elge Comperssor No. 1

132KV Substation Almora

Page 2: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

49132KV Isolator Clamp suitable for ACSR

Panther ConductorNo. 4

5033KV C.T. Connector suitable for ACSR

Panther Conductor

No.8

51 PVC Control Cable 6 Core Km. 0.1352 PG Clamp Z/Z No. 24

53

Galv. Nut & Bolts of dia 06mm & length

62.5mm with spring & plane washer 02mm

thicknessNo. 434

54

Galv. Nut & Bolts of dia 06mm & length

75mm with spring & plane washer 02mm

thicknessNo. 336

55

Galv. Nut & Bolts of dia 06mm & length

100mm with spring & plane washer 02mm

thicknessNo. 500

56

Galv. Nut & Bolts of dia 08mm & length

50mm with spring & plane washer 02mm

thicknessNo. 308

57

Galv. Nut & Bolts of dia 08mm & length

62.5mm with spring & plane washer 02mm

thicknessNo. 792

58

Galv. Nut & Bolts of dia 08mm & length

75mm with spring & plane washer 02mm

thicknessNo. 886

59

Galv. Nut & Bolts of dia 08mm & length

100mm with spring & plane washer 02mm

thicknessNo. 961

60

Galv. Nut & Bolts of dia 12mm & length

62.5mm with spring & plane washer 02mm

thicknessNo. 56

61

Galv. Nut & Bolts of dia 12mm & length

75mm with spring & plane washer 02mm

thicknessNo. 856

62

Galv. Nut & Bolts of dia 12mm & length

100mm with spring & plane washer 02mm

thicknessNo. 276

63 Hydro Meter No. 264 Trip Normally Closed switch No. 2

65Tripping Coil for 132KV SF-6 Circuit Breaker

No. 2

66Closing Coil for 132KV SF-6 Circuit Breaker

No. 1

67 Tripping Coil for 33KV Circuit Breaker No. 168 Closing Coil for 33KV Circuit Breaker No. 2

69Antipumping Relay for 33KV Circuit Breaker

No. 2

70Auxiliary switch 13No+13Nc for 33KV Circuit.

BreakerNo. 2

71 MS Angle 65x65x6mm Kg. 7072 Control cable 10x2.5Sqmm Mtr. 15073 Control cable 2x2.5Sqmm Mtr. 100

74

Surge Counter at 33Kv Lightening Arrester

LSM type long duration discharge class

3.50Hz with fixing base arrangementNo. 10

75 33KV CT Junction Boxes No. 5

76Self spraying Container for CRC in 415ml.

No. 3

7740 watt 250volt 04 feet long tube light, Bajaj

make.No. 4

78 33KV 4.5 Amp. High Glass Fuse No. 18

79Contractor for Spring Charge Motor 110 volt

DCNo. 2

80Contractor for Low Gas Pressure 110 volt DC

No. 2

81 Closing Coil for 110 V. DC, CGL Make No. 282 Tripping Coil for 110V.DC, CGL Make No. 183 MCB 230 volt AC 2 Amp. No. 1

Page 3: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

84 Limit switch 110 volt DC 01 Amp. No. 2

85 Galv. Anchar Bolts, size 28mm dia, 700mm

length & 50mm bended with NutsNo. 12

86 3 Bolted PG Clamp Z/P No. 17

87Spring Charge Motor for 33KV SF-6 CB (ABB

Make)No. 1

88Tripping Coil for 33KV SF-6 C B (BHEL Make)

No. 4

89Closing Coil for 33KV SF-6 C B (BHEL Make)

No. 2

90 HRC Fuse 4 Amp. Havells/GE make No. 291 HRC Fuse 6 Amp. Havells/GE make No. 1092 22KV Post Insulator No. 1293 J-Type Hooks No. 3594 PRV for 20MVA Power T/F No. 195 L/R Switch for 33KV VCB (BHEL Make) No. 496 NIT Switch No. 3

97Auxiliary Conteractor for Density Monitor

110/220 Volt DC

No.3

986 Bolted Terminal Connector for ACSR Dog

Conductorof 33KV Isolator No. 10

99 PRV for 20MVA Power T/F (Defective) No. 1

100132KV Isolator Clamp for ACSR Panther

ConductorNo. 20

101 Heavy duty treminal connector 6 bolted for

ACSR Panther Conductor for 132KV IsolatorNo. 6

102Vacuum Interrupter Bottle for 36KV VCB ABB

MakeNo. 1

103Vacuum Interrupter Bottle for

36KV,1250Amp.25KA, VCB BHEL MakeNo. 1

104C-Wedge Clamp Suitable for ACSR P/P

ConductorNo. 22

105C-Wedge Clamp Suitable for ACSR Z/P

ConductorNo. 16

1061-Phase 230 Volt AC Spring Charge Motor

33KV SF-6 Gas CGL make C.B.No. 1

1071-Phase 230 Volt AC Spring Charge Motor

33KV SF-6 Gas BHEL make C.B.No. 1

108 6 Bolted terminal Clamp for 33Kv CB No. 12109 Power Switch 15Amp. 250volt 50Hz No. 2

110PVC Multi stand Copper wire size 1.0 Sqmm

Mtr. 268

111PVC Multi stand Copper wire size 1.5 Sqmm

Mtr. 30

112Bimetallic Connector for STEM and ACSR

Panther Conductor

No.14

113 ACDB for Control Room Light No. 1

114 ACDB for NXEY Light No. 1

115HDE Copper Tube for 33KV Isolator 800

Amp. No. 6

116HDE Copper Tube for E/S of 33KV Isolator

800 Amp. No. 5

117HDE Copper Flat for E/S of 33KV Isolator 800

Amp. No. 5

118HDE Copper Tube for 33KV Isolator 1200

Amp. No. 9

119HDE Copper Jaw for 33KV Isolator 1200 Amp.

No. 18

120

Galv. Nut & Bolts of dia 08 mm & length

50mm with spring & plane washer 02mm

thicknessNo. 546

121

Galv. Nut & Bolts of dia 10 mm & length

50mm with spring & plane washer 02mm

thicknessNo. 404

Page 4: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

122

Galv. Nut & Bolts of dia 10 mm & length

62.5mm with spring & plane washer 02mm

thicknessNo. 348

123

Galv. Nut & Bolts of dia 10 mm & length

75mm with spring & plane washer 02mm

thicknessNo. 320

124

Galv. Nut & Bolts of dia 10 mm & length

87.5mm with spring & plane washer 02mm

thicknessNo. 480

125

Galv. Nut & Bolts of dia 10 mm & length

100mm with spring & plane washer 02mm

thicknessNo. 404

126

Galv. Nut & Bolts of dia 16 mm & length

75mm with spring & plane washer 02mm

thicknessNo. 776

127 Galv. Stud No. 1650

128Copper Blade for 33KV Isolator 1200 Amp.

No. 3

129Copper Jaw for 33KV Isolator 1200 Amp.

No. 6

130 36KV L/A IS-3070 P-2,Class3,5KJ/KV No. 3

131Fresh Electrol Transformer Oil as per IS

1993/335Kl. 0.627

132Digital Ampere Meter size

150x150mm,CTR 400/1ANo. 4

133Digital Ampere Meter size

95x95mm,CTR 400/1ANo. 2

134Digital Ampere Meter size

150x150mm,CTR 300/1ANo. 1

135Digital Ampere Meter size

150x150mm,CTR 200/1ANo. 2

136Digital Ampere Meter size

150x150mm,CTR 100/1ANo. 2

137Digital KV Meter size 150x150 mm,PTR

132KV/110 VoltNo. 2

138Digital KV Meter size 150x150 mm,PTR

33KV/110 VoltNo. 2

139Digital MW Meter size 150x150 mm,CTR

400/1A,PTR 33KV/110 V.No. 1

140 Digital MW Meter size 150x150 mm,CTR

400/1A,PTR 33KV/110 V(Faulty)

No. 1

141Digital MVAR Meter size 150x150

mm,CTR 400/1A,PTR 33KV/110 V.No. 2

142Digital Ampere Meter size

95x95mm,CTR 50/1ANo. 2

143Stainless steel T/F Oil Sampling

Container of 2 Ltr. CapacityNo. 3

144Latic type structure foundation bolt (0.207

MT/90 No.)MT 0.207

145 2.5 mm2 10 Core Cable Km. 0.507146 2.5 mm2 6 Core Cable Km. 0.354147 33 KV Post Insulator No. 9

148Compressur type doble taintion fitting for

ACSR Panther conductorNo. 2

149

Single tention Compression type fitting

complete suitable for ACSR Panther

conductorNo. 4

150Vibration Damper complete suitable for

ACSR Panther conductorNo. 10

151Flexible copper Bond rope type including

both side copper lugsNo. 20

152Vibration Damper size 7/3,15mm for G.S.

Earth wire completeNo. 10

Page 5: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

153Jumper Cone lugs suitable for ACSR Panther

conductor No. 20

154 33KV PT Clamp No. 3155 3 bolted PG Clamp P/P No. 29

15636 KV 1 Phase PT in ratio 33KV / 110 Volt

No. 1

157best quality heavy duty 3 bolted PG Clamp

suitable for Panther to Panther Condutor No.18

158best quality heavy duty 33 KV Isolator clamp

suitable for panther conductor No. 8

159 C wedge clamp Dog to Panther No. 35160 132 KV CT ratio 800/400/200/1-1-1A No. 3161 132 KV CT ratio 800/400/1-1A No. 3162 132 KV CT ratio 400/200/1-1A No. 3163 33 KV CT ratio 200/100/1-1A No. 5164 33 KV CT ratio 400/200/1-1A No. 25165 33 KV CT ratio 300/150/1-1A No. 3

166Tripping Coil 110volt DC for 33KV ABB

Make CB No. 4

167Closing Coil 110volt DC for 33KV ABB

Make CB No. 3168 Cotton Dhoti No. 4

169132 KV Lightening arrester120 kv/10KA,class-

3 with surg monitor,connecting

leads,insulating base & terminal connector No. 1170 counter for lightening arrester No. 1171 Joist 70X125X4 K.G 46.4172 M.S. Channel 125X65 mm with (Scrap) K.G 340173 H.F. Cable Mtr. 875174 Rail Pieces 90 C+S No. 2

17548 V.AFCO make Bettery Charger D.C., D.B.

No. 1

176 33 KV C.T. 200 /100/1A (Old & used) No. 1177 T/F oil carbonized (Old) Ltr. 2020178 T/F oil Old & used Ltr. 1000

179Data power E-Meter KWH Class 0.5 S (Old)

No. 1

180 Porcilen Pole (U/S) No. 1181 Radiator Bank Support No. 4182 Copper Jumpering Pipe No. 5183 33 KV Bus Isolator (Incomplete) No. 2184 Galv. Tower Part for "C" Type Tower M.T. 5.259185 Templete for "C" Type Tower 3 No. M.T. 1.42186 Templete for "S" Type Tower 1 No. M.T. 0.46187 Templete for "S

2" Type Tower 1 No. M.T. 0.445

188 Templete for "DC" Type Tower 1 No. M.T. 0.823189 Alternator (U/S) No. 1190 Tyre (damaged) No. 8

191ACSR Panther Conductor (Scrap & Damage)

K.M. 0.933

192Tension fitting for comprection Type for

Panther Conductor (Damaged)No. 1

193 U. B. +0 type Tower Part Galv. M.T. 2.513

194Cross Aram for UB +0 Type Tower (damaged)

K.G. 88.024

195 145 KV CVT (Diffeted) No. 3

196Solid Core Post Insulator (dismental & Old)

No. 21

197 C.T. Shorting connector No. 5198 132 KV C.T. Connector No. 12

Page 6: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

199 33 KV Bulk O.C.B. BHEL (Dismental & Old) 2

No. Auxulary switch & 2 No Busing damagedNo. 5

20033 KV MOCB (BHEL make) Dismental & Old

No. 3

201132 KV L/A Old & used (Dismental & Old)

No. 9

202 33 KV L/A Old & used (Dismental & Old) No. 6

203132 KV MOCB with structure (Dismental &

Old)No. 2

204 145 KV CVT (Old & used dismental) No. 1

205

66 KV MOCB with one pole operating

mechanism & structure (Dismental & old &

damaged)No. 1

20666 KV MOCB with mechanasim & structure

(Dismental & Old)No. 1

207 66 KV MOCB without pole with mechanasim

& structure (Dismental & Old & Damaged)No. 1

208 Empty Oil Drum No. 32209 66 KV C.T. (Damaged) No. 1210 132 KV Bushing Assamble (Old) No. 1211 Tripping spring for 66 KV MOCB No. 2212 Nuts & Bolts mixed off size 5/8", ½ " K.G. 33213 Moving contact for 33 KV OCB (O/S) No. 11214 Battery cotainer (O/S) No. 2215 Universal Moter (Damaged) No. 1216 Alka Pe solder (O/S) K.G. 1

217Extingusher Chamber for 66 KV MOCB (Old &

damaged)No. 1

218Fixed contact 1200 Amp. For 66 KV MOCB

No. 1

219 M.W.H. meter ( Old & used) No. 7

220V. Meter 2.0 V cell tester (Old & Diffective)

No. 1

221 Coper Burned (Old) K.G. 0.5222 Gas Cylinder S F - 6 No. 2223 Surj Conter for L/A (Old &Damage) No. 2

224Porceline Pole for 33 KV MOCB (Old &

damaged)No. 1

225 Auxilary C.T. 1/0.577 No. 1226 Auxilary C.T. (Diffected damaged) No. 3227 Reley (Diffected damaged) No. 2228 K.w.H. Meter (Diffected) No. 1229 13 VR-VAA No. 2230 Carrier Cabinet (dismental & Old) No. 3

231English Electric Relay Type CoQ (Dismental &

Old)No. 2

232T/F Diffrential Rrelay Type DTH-31

(Deffective)

No.1

233C.C.R. Galv. Structure 01 set with Nuts Bolts M.T. 0.5246

234C.G.R. Galv. Structure 01 set with Nuts Bolts M.T.

0.3395

235A.B.L. Galv. Structure 02 sets with Nuts Bolts M.T.

0.7383

236C.P.R. Galv. Structure 01 set with Nuts Bolts M.T. 0.0748

237 ACSR Zebra Conductor in cut pieces O/U Mtr. 50

238LT AC Distribution board (Old &

Unrepairable) No. 1

239Defective spring charge Moter for 33KV Ckt.

BreakerNo. 1

240 132KV MOCB (Unserviceable) No. 1241 33 KV CT of Ratio 200/100/1A (Old) No. 3

Page 7: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

2421-Phase Spring Charge Motor for 33KV SF-6

CB CGL Make (Defective)No. 1

243145 KV L/A with Insulating Base & S/M

(Damage)No. 1

244110V. DC Distribution Board (Unserviceable)

No. 1

245 33KV Isolator Blade (Out of Service) No. 9246 33KV Isolator Jaw (Out of Service) No. 19247 Bucholz Relay (Deffective) No. 1248 Magnetic OLG (Deffective) No. 1249 Oil Surge Relay (Deffective) No. 1250 33 KV 3 Phase Reactor (O/U) No. 4251 66KV LA (Old &Diffective) No. 3252 33 KV CT (Old&Diffctive) No. 2253 2 V Battery cell(old and used) No 55

25433 KV CB (ABB make) Dismental , Old &deff.

No. 1

255 LED Street light 70 watt A.C. No. 9

256 LED Bulb 15 watt A.C. No. 13

257 Danger board of size 325*170 mm Nos 96

258 Number plate of size 25*200 mm Nos 85

259 phase plate of size 100 mm Nos 22

260Earth wire SWG 7/10 old , used and in pieces Kg. 13800

261 SF-6Gas Kg. 15

133KV/110V burst &damaged P.T.

without oil No. 1

211KV, 630 A, 350 MVA ,V.C.B. incoming

panel make C.G.L. Nos. 1

311KV, 630 A, 350 MVA,V.C.B. outgoing

panel make C.G.L. Nos. 2

411KV, 630 A, 350 MVA ,V.C.B. bus

coupler make C.G.L. No. 1

5B.O.C.B. 33KV old damaged without oil

incomplete No. 1

6 B.O.C.B. 33KV old and used No. 1

7 Transformer Oil (Carbonised) Ltr. 150

8Transformer old and used single phase

66/33KV2.5MVA Nos. 3

9Bus isolator 33kv old and used

incomplete No. 1

10 145KV C.V.T. ABB make Nos. 3

11 Empty transformer oil drum Nos. 135

12 Tripping coil 110V No. 1

13 P.G. clamp deer to panther (D/P) Nos. 14

14Galvanised earth wire for 7/10 S.W.G.

(SCRAP) Mtr. 1202

15 Galvanised nut and bolt M16X85 MM

Nos. 50

16Bolted type tension fitting for panther

Nos. 4

17Double tension fitting for panther

incomplete Nos.

12

18Galvanised nuts and bolts M16X35 MM

Nos. 158

19Galvanised nuts and bolts M16X50 MM

Nos. 1964

20 Galvanised pack washer M16X8 MM Nos. 115

132KV S/S Pithoragarh.

Page 8: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

21 Empty cement bag Nos. 4504

22 11 KV. pin Nos. 8

23Battery set 110V, 60AH, old used and

unserviceable set 1

24Galvanised nuts and bolts M16X40 MM

Nos. 338

2511 KV Cable box XLPE 3X400 Sq.mm

outdoor type

No. 1

26 132/33 KV jaw Nos. 6

27 M.S. round 36 mm Kg 282.90

28 Aluminium Strip 3X2.5 mm Mtr. 37

29 P.G. Clamp Zebra to Panther Nos. 17

30 Old and used Transformer Oil Ltr. 8665

31 Damaged ACSR Panther conductor Mtr. 568

32 ACSR Zebra conductor in pieces Mtr. 68.5000

33Damaged ACSR Zebra conductor in

pieces Mtr.

66

34Old & used O/C ,E/F relay (Inverse Type)

CDGNos. 3

35Defective Energy Meter 3Phase

,3Wire(Secure meter Ltd.)Nos. 3

36 Oil Surge Relay No. 1

37O.T.I. Meter with two mercury switch

Nos. 1

38 4 Mercury Switch W.T.I. No. 1

39 Bucholtz relay damaged(defective) No. 2 2

40 Defective Oil surge relay No. 2

41 Defective OTI meter No. 3

42 Defective WTI meter No. 3

4366kv dismanteled colums with nuts &

boltsMT 2.677

44 63Amp. 4 pole MCCB no. 14

45PG clamp Panther to Racoon with 13

mm dia 3 bolted typeno. 8

46PG clamp Zebra to Dog with 16 mm dia 4

bolted typeno. 9

47132 KV three core CT having CT ratio

800/400/1A(Hepta care)no. 1

48440v,63A TP Iron clad switch make

Havellsno. 1

49contract 220v ac 38 Amps.440v with

auxliryNo. 2

50 PVC control cable4core km 0.30

51 PVC control cable6core km 0.065

5233kv Isolator clamp suitable for panther

conductorNo. 1

53 Energy meter No. 1

54 Surge counter of 132kv LA LSM type No. 2

55 PVC control cable10x2.5 sqm Mtr. 142

56Galv. Steal structure with bolts &

nuts(1no. Colum )MT 0.845

57 Defective magnetic oil guage meter No. 2

58 Defective AC fail relay No. 1

59Defective AC trip ckt. Supervision relay

No. 1

60Damaged old & used OLTC panel of

3x5mva T/f-1&2,&20mva T/fNo. 3

61Damaged old&used 33kv feeder panel

No. 2

Page 9: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

62 Tripping coil 110v Dc for ABB breaker

No. 4

63 Closing coil 110v Dc for ABB breaker No. 5

64 132 kv Isolator Clamp No. 1

65 ACSR Moose Conductor km 0.098

66 70.kn Disc Insulator No.s 4

67 Defective butterfly valve No.s 6

68 Defective gate valve No.s 5

69 PVC control cable 6x2.5 Sqmm Km. 0.524

70Wire mesh fencing with four row barbed

wireMtr. 20

71 nitril gasket 6mm thicknessSqm

m8.40

72 nitril gasket 8mm thicknessSqm

m 9.620

73 nitril gasket 10mm thicknessSqm

m 5.92

74Damaged old & used Dc charger Panel

nos.1

75 magnetic oil level guage nos. 1

76PG Clamp Dog to dog with 3 boletd type

nos.2

77PG Clamp Panther to dog with 3 boletd

typenos.

7

78PG Clamp Moose to Panther with 3

boletd typenos.

2

79 145 KV LA with surge counter nos. 1

80 MS Rod 36 MT 0.409

81bolted type tensison fitting for Panther

Conductor

Nos.

6

82Old & Used bolted type tensison fitting

for Panther ConductorNos.

6

83bolted type tensison fitting for Moose

Conductor Nos. 4

84 ElectrolT/F oil as per Is 335:1993 KL 1.881

85145 KV CT 200/100/1A with terminal

connector Nos. 3

86 repaired 132 KV CT 800/400/200/1A Nos. 1

8702 V 300 AH Battery Cell Old & Used

Damaged Nos. 10

88C-wedge clamp suitable for ACSR Zebra

to Panther conductor Nos. 9

89 Defective shut off valve Nos. 3

90 Defective gate valve Nos. 1

91 Defective PRV Nos. 3

92 Closing coil CG make Nos. 1

93 Tripping Coil ABB Make Nos. 3

94 Closing Coil ABB Make Nos. 3

95Defective Spring charge motor of 33 kv

ckt. Breaker (ABB) Nos. 2

96

Heavy Duty Terminal connector 6 bolted

for ACSR Dog conductor for 33 KV

Isolator Nos. 12

97 Jaw of 33KV Isolator Nos. 5

98

Heavy Duty Terminal connector 6 bolted

for ACSR Panther conductor for 132 KV

Isolator

Nos.

11

99 Jaw (finger) of 132 KV Isolator Nos. 8

100Tripping coil of 132 Kv SF6 Ckt. Breaker

of AREVA makeNos.

2

Page 10: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

101Single phase Spring charge motor for 33

KV SF6 Ckt. Breaker CGL makeNos.

1

102Tripping coil of 132 Kv SF6 Ckt. Breaker

of ABB makeNos.

2

103Anti pumping Relay for 33 Kv Abb Make

VCB

Nos.

2

104Old & Used Isolator Clamp For double

Panther ConductorNos.

6

105Defective Spring charge motor for 33 Kv

BHEL Ckt. BreakerNos.

1

106Old & Used 33 KV XLPE Cable in Pieces

Mtr.81

107Old & UsedAnalog Amp & Volt Meter

Nos.17

108Defective digital Amp./ Volt,MW &

MVAR MeterNos.

13

109 Bucholz relay for transformer Nos. 1

110 33 KV CT 300/150/1 Amp. Nos. 3

111 Stainless steal transformer oil sample

container (SS304)of 02 ltr. Capacity

Nos.

6

112 Stainless steal transformer oil sample

container (SS304)of 01 ltr. Capacity

Nos.

3

113 damaged old & used silica gel jar Nos. 8

114 old & Used analog MW/Mvar meter Nos. 2

115

33 KV Current Transformer Having ratio

of 400/200/1 Amp. Accuracy class 0.2

Make-Savio

nos.

1

116 33 KV CT 200/100/1 Amp. nos. 1

117CT Connector Suitable for ACSR Panther

Conductornos.

2

118 Sulfur Hexa Fluride (SF-6) Gas kg 10

119 Damaged capacitor cell Nos. 1

120 33 KV Potential Transformer (single phase)Nos. 2

121566 KVAR Capacitor Cell suitable for2x5

MVAR capacitor bank Nos. 1

1223.5 X 70 mmsquare Armourd LT Power

cable Mtr. 132

123Tripping Coil 110 V DC for 33KV BHEL

Ckt. Breaker Nos. 5

124Limit Switch for 33 KV VCB,ABB

Make Nos. 1

125Old & Used 132 KV Ckt. Breaker (ABB) Nos. 2

126Old & Used 33 KV Ckt. Breaker

(VCB)BHEL Nos. 1

127Old & Used 132 KV CT 800/400/200/1

Amp Nos. 2

128Old & Used 132 KV CT /400/200/1 Amp Nos. 1

129 Old & Used 33 KV CT 400/200/1 Amp Nos. 3

130 Old & Used 30 KV LA Nos. 6

131EHV Grade Transformer oil,Conferming

IS:335 :1993 KL. 11.495

132Old & Used PG Clamp Panther to

Panther Nos. 10

133 Old & Used PG Clamp D to Panther Nos. 6

134ld & Used PG Clamp Zebra to Panther Nos. 10

Page 11: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

135Old & Used PG Clamp Moose to Panther Nos. 15

136 Ckt. Breaker Terminal Connector Nos. 3

1372.5 mm square Alluminium wire

bundle(90 mtr.each) Nos. 3

1381.5 Sq.mm Flexible wire roll (90 mtr.

Each) Nos. 2

139Old&used, Damaged 33kv Tripple

feeder panel Nos.1

140Old&used, Damaged 33kv Double

feeder panel Nos.2

141Old & Used Energy Meter 3Phase ,

3Wire Nos.6

142Old & Used Energy Meter 3Phase ,

4Wire Nos.12

1 AA0A004001 ACSR Conductor Zebra Mtr. 1434

2 AA0A005001 ACSR Conductor Panther Mtr. 2

3 AA1A101001 GI Earth Wire 7/9 SWG Mtr. 388

4 AA5A501004 IPS Aluminium Tube 4" Mtr. 37

5BB0B002001 Capacitor Cell- 552.50 KVAR 10.96 KV No 1

6 BB4B401001 NCT- 5/1Amp No.

7CC0C002008

PVC Control Cable - W/o Armoured-

10x2.5mmMtr

8 CC0C002010 PVC Control Cable - 6x2.5mm Mtr 500

9

CC1C102002 Power Cable -440V LT - - 3.5x400

Sq. mmMtr

10

CC1C102010 Power Cable -440V LT - -

3.5x35Sq. mmMtr 270

11

CC1C102010 Power Cable -440V LT - -

3.5x70Sq. mmMtr

12

CC2C201007 Control Cable- Armoured- - 6Cx2.5

Sq. MMtr

13CC2C201009

Control Cable- Armoured- - 4Cx2.5 Sq.

MMtr 155

14

CC2C201011 Control Cable- Armoured- - 2Cx2.5

Sq. MMtr

15 CC4C401001 HF Cable -75 Ohm HP CABLE- Mtr

16 FF2F207021 Template D Type for 220KV Double Circuit MT 5.911

17 FF2F207029 Template A Type for 132KV Double Circuit MT 0.532

18 FF2F207031 Template B Type for 132KV Double Circuit MT 0.2832

19 FF2F207033 Template C Type for 132KV Double Circuit MT 1.089

20 FF3F302001 Tower Parts- GI MT 1.63

21 FF7F702005 MS Flat- 32x6mm MT 0

22GG0G001003

Maintenance material CRC 400 ML

Bottel No 2

23HH0H002002

Line Isolator 220 KV Motorized with

Earth Switch No 1

24HH0H003001 Line Isolator 132 KV with Earth switch No 1

25 HH5H502001 220 KV Isolater Spare Fixed contact Set 1

26

27HH5H503001

220 KV Isolater Spare Isolator Rotating

Assembly No 2

28HH5H506002

220 KV Isolater Spare Switch 220V Limit

Switch for Motorized IsolatorsSet 4

220 KV S/S Mahuakheraganj

Page 12: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

29HH6H601001

132 KV Isolater Spare Jaws Female

contact 1250 AmpNo 4

30HH6H602001

132 KV Isolater Spare Blade Male

contactNo 4

31

HH8H803001

33 KV Isolater Spare Isolator Rotating

Assembly Motorized operating

mechanism with earth link operation

box

No 1

32

HH8H803002

33 KV Isolater Spare Isolator Rotating

Assembly Motorized operating

mechanism for Isolator

No. 3

33 HH9H901007 Isolator Clamp Twin moose No 7

34 HH9H901008 Isolator Clamp Single moose No 3

35 HH9H901023 Isolator Clamp Terminal Pads No. 4

36 II0I001001 Disc Insulator 160 KN Porceline No 76

37 II0I002001 Disc Insulator 120 KN Porceline No 261

38 II0I003001 Disc Insulator 90 KN No 29

39 II0I004001 Disc Insulator 70 KN No

40 II1I102004 PG Clamp Moose- Panther No 12

41 II1I104001 PG Clamp Zebra- Zebra No. 14

42 II1I104002 PG Clamp Zebra- Panther Mtr

43 II1I105001 PG Clamp Panther- Panther No. 4

44 II2I202001 C-wedge Clamp Moose- Moose No 20

45 II2I204001 C-wedge Clamp Zebra- Zebra No. 72

46 II2I204002 C-wedge Clamp Zebra- Panther No.

47 II2I205001 C-wedge Clamp Panther- Panther No. 134

48 II3I302001 T-Connector Moose- Moose No 5

49 II5I501003 Mid Span Joint Zebra No 9

50 II5I501004 Mid Span Joint Panther No 10

51 II5I502003 Repair Sleeve Zebra No 14

52 II5I502004 Repair Sleeve Panther No 5

53 II5I503004 Vibration Dampher Panther No

54 II7I704003 Spacers Quard Moose No 6

55 II7I704004 Spacers Twin Moose No 35

56 II8I801004 Single Tension Fitting Zebra No 1

57 II8I801005 Single Tension Fitting Panther No 12

58 II8I802002 Double Tension Fitting Moose No 6

59 II8I803001 Quard Tension Fitting Moose No 6

60 II8I804005 Single Suspension Fitting Panther No 3

61JJ0J003001 Single pole Circuit Breaker 132KV SF-6 No 1

62JJ1J102003

Circuit Breaker Sapres 220KV Trip Coil

AssemblyNo 1

63JJ1J102004

Circuit Breaker Sapres 220KV Closing

CoilNo 2

64JJ1J102005

Circuit Breaker Sapres 220KV 220V

Closing CoilNo 1

65JJ1J102006

Circuit Breaker Sapres 220KV Closing

Coil AssemblyNo 1

66JJ1J102008 Circuit Breaker Sapres 220KV Poles No 1

67JJ1J102009

Circuit Breaker Sapres 220KV Moving

Contact/ Male ContactSet 1

68JJ1J102011 Circuit Breaker Sapres 220KV O Ring Set 1

69JJ1J102014

Circuit Breaker Sapres 220KV Gas

pressure SwitchSet 1

70

JJ1J102020Circuit Breaker Sapres 220KV

Complete Spring oprating Mechanism1

Page 13: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

71JJ1J103001

Circuit Breaker Sapres 132KV 220V DC

Trip CoilNo 4

72JJ1J103002

Circuit Breaker Sapres 132KV 220V DC

Trip Coil AssemblyNo 1

73JJ1J103003

Circuit Breaker Sapres 132KV 220V DC

Closing CoilNo 4

74JJ1J103004

Circuit Breaker Sapres 132KV 220V DC

Closing Coil AssemblyNo 1

75JJ1J103005

Circuit Breaker Sapres 132KV 110V DC

Trip CoilNo

76JJ1J103007

Circuit Breaker Sapres 132KV Moving

Contact/ Male Contact1

77JJ1J103008

Circuit Breaker Sapres 132KV Fixed /

Female/ Copper Contact1

78JJ1J103010

Circuit Breaker Sapres 132KV Spring

Charging MotorNo 0 1

79JJ1J105034

Circuit Breaker Sapres 33KV Charging

MotorsNo 0

80 KK0K002001 Lighting Arrestor 220 KV No 2

81 KK0K003001 Lighting Arrestor 132 KV No

82 KK0K005001 Lighting Arrestor 33 KV No 3

83

KK4K302001

Bus Post Insulator (without corona ring)

with creepage distance of 6125 mm. -

245 kV

No 15

84

KK4K302002

Bus Post Insulator (without corona ring)

with creepage distance of 3625 mm. -

145 kV

No 13

85 KK4K401005 Post Insulator 33KV No.

86LL0L001003

HPSV Lighting Material HPSV Lighting

Complete 400WNo. 4

87 LL0L003003 HPSV Lighting Material Lamp 400W No. 4

88LL0L004003 HPSV Lighting Material Ignitor 400W No. 8

89LL3L303002 Flurocent Light Flurocent Tube 36W No.

90 LL4L402005 C.F.L. C.F.L Lamp 27 Watt No.

91 LL4L402007 C.F.L. C.F.L Lamp 23 Watt No.

92LL6L602003

Lighting Spares PVC Multi stand Copper

wire size Red 2.5 sqmmNo. 4

93LL6L602004

Lighting Spares PVC Multi stand Copper

wire size Yellow 2.5 sqmmNo. 0

94

MM0M00100

3

Relay - Distance Relay - Main-1

Numerical Distance relay( excluding

external trip relay)with accessaries

No 1

95

MM0M01900

1

Relay - Diffrential Relay - Transformer

differential protection relay with

assesiores

No 1

96

MM0M01900

2

Relay - Diffrential Relay - Reactor

differential protection relayincluding all

aux. CT and associated software

No 1

97

MM0M02000

1

Relay - Disturbance Recorder -

Disturbance recorder acquisition

unitswith Software

Set 1

98

MM0M02100

1

Relay - Distance to fault locator -

including mutual compasation unitsSet 1

99

MM0M02200

1Relay - Over load relay - with timer Set 1

Set

Page 14: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

100

MM0M02400

2

Relay - Back up for protection relay -

Back up for protection relay with 3O/C

and 1 E/F element

No 1

101

MM0M02500

1

Relay - Back up impedance relay - Back

up impedance relaySet 1

102

MM0M02600

1

Relay - Restricted earth fault protection

relay - with Non-linear resistor Type-

SR350 relay

No 3

103

MM0M02700

1

Relay - Over Fluxing Relay - Over fluxing

relaySet 1

104MM0MO32001Relay - Breaker failure relay - for 220 KV No 1

105MM0MO32002

Relay - Breaker failure relay - for 132

KV@240No 1

106

MM0M038002Relay - Over Voltage Protection Relay -

over voltage protection relay with timersSet 1

107

MM0M071001Relay - TP Differential Proction Relay

Setting 10-40% Ctr-1a Supply 220VDC - No. 1

108

MM0M072001Relay - TP O/C Relay 50-200%(Valtage

Operated O CTR 1A, 90.3SEC) 220VDC - No. 1

109

MM0M073001

Relay - 220VDC Earth Leakage

Relay,Satting 3.7MA AUX Supply 230VAC

-

No 1

110MM0M074001

Relay - TP Istant O/C Relay With Adj Defl

Mani Time CTR-1A,200-800% - No 1

111MM0M075001

Relay - Master Trip Relay Aux. Supply

220VDC 4NO+1 No. - No 1

112

MM0M076001Relay - Insant E/F Relay With Adj Deft

Mini Time,Ctr-1a,10-40% 220VDC - No. 2

113MM3M301014

Digital Meter - Volt Meter - Volt Meter

Digital voltmeterNo. 3

114

MM3M307007

Digital Meter - KWH (Energy meter) -

Energy meter 3Phase 3wire 110V 5A

50HZ KWH Secure meter LTD old&usedNo.

115 SS3S301012 Fuse HRC Link type - 32 Amp No 44

116 SS4S401002 MCB 220V DC Double Pole 10 Amp No 2

117 SS4S404003 MCB 230V AC Single Pole 16 Amp No 7

118 SS4S405006 MCB 415 AC Tripple Pole 6 Amp. No. 7

119 VV2V204015

Terminal connector for bushing. HV-40

MVANo

120 VV2V204016

Terminal connector for bushing. LV-40

MVANo

121VV6V602001

Current Transformer 245KV

1600/800/1A 5 core Accuracy 0.2No. 1

122VV6V602004

Current Transformer 245KV

800/400/200/1A 5 core Accuracy 0.2No. 0

123VV6V603001

Current Transformer 145KV 800/400/1

A 5 core Accuracy 0.2No. 2

124VV6V605002

Current Transformer 33 KV

1600/800/1A 3 Core Accuracy 0.2No 2

125 VV6V605006

Current Transformer 33 KV 800-

400/1A 3 core No 2

126VV6V605008

Current Transformer 33 KV

400/200/1A 3 core Accuracy 0.2No

127VV6V605013

Current Transformer 33 KV 200-

100/1Amp 3 Core No

Page 15: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

128VV8V803002

PT (Potential Transformer) 145 KV PT 3

core with one 0.2 accuracyNo 1

129VV8V805001

PT (Potential Transformer) PT 3-phase

33KV/110 Volt -No 1

130VV8V805002

PT (Potential Transformer) PT 1-phase,

33KV/110 Volt -No 2

131 VV8V810002 CVT CVT 220 KV/110 Volt - No 2

132

VV8V810003 CVT CVT - CVT 132 KV/110 Volt - 145kv No

133 VV8V811010 Grading capacitors 220KV No. 1

134 VV8V811011 Grading capacitors 132KV No 1

135 YY1Y101005 Battery Cell 2 V 300AH lead acid No 0

136YY2Y207001

Battery Spares Inter cell connector with

bolts and nuts for 300 AHNo 7

137 SF6 gas@ Kg 17.00

138

Molecular filter for SF6 Circuit

for 1 Pole of Circuit

[email protected]

Set

3.00

139

Density/Pressure monitor for

SF6 circuit for one pole of

[email protected]

No.

1.00

140

Pressure gauges & coupling

devices of each type.@26553 set

1.00

141 Operating counter No. 1.00

142

Grading capacitors 220KV

@181000No.

1.00

143

All types of coupling for SF6

gas@8859No.

1.00

144 Corona rings@30256 No. 1.00

145

Definite time [email protected].

1.00

146 Control [email protected] No. 8.00

147 Control Valves@38000 Set 1.00

148 Pressure switches@8892 Set 1.00

149 Closing dash pot@16500 Set 1.00

150 Opening dash pot@18000 Set 1.00

151 Opening Latch gear@9883 Set 1.00

152 Closingh Latch gear@9500 Set 1.00

153

Terminals [email protected] No.

2.00

154

Corona shielding ring of each

[email protected]

4.00

155 Bearings @12856 Set 2.00

156

Interlocking coils with

[email protected] No.

5.00

157

Molecular filter for SF6 circuit

for one pole of [email protected] Sets

3.00

Page 16: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

158

Density/Pressure Monitor for

SF6 circuit for one pole of

[email protected]

No.

1.00

159

Pressure gauge and coupling

device of each type@22648Set

1.00

160Operation counter@2566

No.1.00

161

All types of coupling for SF6

gas@7884No.

1.00

162 Corona rings@30256 No. 1.00

163 Control Relay@8233 No. 8.00

164 Resister@8852 No. 1.00

165 Control Valves@38000 Set 1.00

166 Pressure switches@7885 Set 1.00

167 Closing dash pot@16500 Set 1.00

168 Opening dash pot@14332 Set 1.00

169 Opening Latch gear@8883 Set 1.00

170 Closing Latch gear@7220 Set 1.00

171

Ammeter with transducer for

220 KV & 132KV@5512No.

4.00

172

Wattmeter with Transducer for

220 KV & 132 KV@12232

No.

2.00

173

VAR meter with Transducer for

220 Kv & 132 KV@12232

No.

2.00

174

Volt meter with Transducer for

220 KV &132 KV@5512No.

2.00

175

Volt meter Selector Switch 220

KV & 132 kV@430No.

2.00

176

Control Switch for Breaker for

220 KV & 132 KV@26567

No.

4.00

177

Control Switch for Isolator 220

KV &132 KV@290No.

4.00

178

Semaphore Indicator for Earth

Switch 220 KV & 132 KV@5234

No.

4.00

179

Red/Green/ White indication

lamp 3 No for Each Color for

220 kv & 132 KV@456

Set

1.00

180

Annunciation windows with

necessary Annunciation relay

for 220 KV & 132 KV@10092

No.

2.00

181

Push Button for 220 KV &

[email protected].

2.00

182

Trip Transfer Switch 220 KV &

132 [email protected].

2.00

Page 17: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

183

Synchornizing socket 220 KV &

132 KV@3524No.

2.00

184

Synchornizing Selector Switch

220 KV & 132 KV@342

No.

2.00

185

2.5 mm copper wire (90 meter

long)@1471.5No.

4.00

186

Shaft sleeves for HVW spray

[email protected]

1.00

187 Self [email protected] No. 1.00

188

Shaft sleeves for hydrant pumps

and jockey [email protected]

Set

1.00

189

Quartzoid Bulb

[email protected].

5.00

190 Projector(merxles)@1050.00No.

2.00

191 Smoke [email protected] No. 2.00

192 Heat [email protected] No. 3.00

193 Deluge [email protected] Set 1.00

194

Isolation Valve(each

size)@8997.0Set

1.00

195

electrical Control panel

Annunciation printed circuit

board in the control

[email protected]

Set

1.00

196 [email protected] No. 1.00

197 level [email protected] No. 1.00

198

safety valve for hydro

pneumatic [email protected]

No.

1.00

199 Pressure switch @4380.0 No. 1.00

200

Bronze pipe fited with nozzle &

guide [email protected]

No.

1.00

201 Hydrant [email protected] No. 1.00

202 Pressure [email protected] No. 1.00

203

Self starter assembly for DG

[email protected].

1.00

204

Soleniod coil assembly for DG

[email protected].

1.00

205 Switches for DG Set@9098 Set 1.00

206 Timer for [email protected] Set 1.00

207

D.C Starter assembly with

clutch engaging and

disengaging arrngement

complet with motor for

DG@25664

No.

1.00

Page 18: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

208

High water temperature safety

control for [email protected] No.

1.00

209

AVR Card type For [email protected].

1.00

210

Inter cell connector with bolts

and nuts for 500 [email protected] No.

10.00

211

Set of Rely for 220 v battery

[email protected]

1.00

212

Set of conntractor 220 V

battery [email protected]

1.00

213

Filter capacitor 220 V battery

[email protected].

1.00

214

Thyristor/diode for 220 V

battery [email protected]

1.00

215

Set of woun resistor 220 V

battery [email protected]

1.00

216

Set of Switches for 220 V

battery [email protected]

1.00

217

Potentiometer for 220 V

battery [email protected].

1.00

218

Fuse of thyristor with indicator

for 220 [email protected].

6.00

219

Set of wound resistor 48 V

battery [email protected]

1.00

220

Set of Switches for 48 V battery

charger@456Set

1.00

221

Potentiometer for 48 V battery

charger@1564No.

1.00

222

Fuse of thyristor with indicator

for 48 V@987No.

6.00

223

220VDC Earth Leakage

Relay,Satting 3.7MA AUX

Supply [email protected]

No.

1.00

224

INSTANT 220VDC,O/V RELAY

Setting 110% Aux

[email protected]

No.

1.00

225

INSTANT 48VDC,O/V RELAY

Setting 110% Aux

[email protected]

No.

1.00

226

INSTANT 220VDC,O/V RELAY

Setting 95% Aux

[email protected]

No.

1.00

227

INSTANT 48VDC,U/V RELAY

Setting 95% Aux

[email protected]

No.

1.00

Page 19: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

228

DC INSTANT U/V RELAY WITH

CONTINEOUS SETTING 40-

48%AUX [email protected] No.

1.00

229

AUX RELAY WITH 2NO SELF

RESET CONTACT

[email protected]

No.

1.00

230

TP ISTANT O/C RELAY WITH ADJ

DEFL MANI TIME CTR-1A,200-

800%@26556.0

No.

1.00

231

MASTER TRIP RELAY AUX.

SUPPLY 220VDC 4NO+1

[email protected]

No.

1.00

232

INSANT E/F RELAY WITH ADJ

DEFT MINI TIME,CTR-1A,10-

40% [email protected]

No.

2.00

233

TP DEFFENTAL PROCTION

RELAY SETTING 10-40% CTR-1A

SUPPLY [email protected] No.

1.00

234

TP O/C RELAY 50-

200%(VALTAGE OPERATED O

CTR 1A,

90.3SEC)[email protected]

No.

1.00

235

CURRENT TRANSFORMER

1000/1A,15VA,[email protected] No.

2.00

236

CURRENT TRANSFORMER

400/1A,15VA,[email protected] No.

2.00

237

CURRENT TRANSFORMER

400/1A,15VA,[email protected] No.

1.00

238

VOLTAGE TRANSFORMER

SINGLE PHASE

415/3,110/3.50VA,CL-

[email protected]

No.

1.00

239

AMMTER SELECTOR SWITCH

[email protected] No.

1.00

240

AMMTER SELECTOR SWITCH

[email protected] No.

1.00

241

SELECTOR SWITCH DP,16A,ON-

[email protected] No.

1.00

242

A/M SELECTOR SWITCH

1P,2W,W/O OFF,[email protected] No.

1.00

243

A/M SELECTOR SWITCH

3P,2W,W/O OFF,[email protected] No.

1.00

Page 20: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

244

AIR BREAKER SWITCH

,250A,220VDC, DP SWITCH

@9237.0

No.

1.00

245

BREAKER CONTROL SWITCH DP

[email protected] No.

1.00

246

DC AMMETER WITH DC SHUNT

0-75MV [email protected] No.

1.00

247

AMMETER 0-1000A CTR CL-

[email protected] No.

1.00

248

AMMETER 0-400 CTR CL-

[email protected] No.

1.00

249

DC VOLMETER 75-0-75V WITH

DC SHUNT CL-0 [email protected] No.

1.00

250

DC VOLTMETER 300-0-

[email protected] No.

1.00

251

VOLTMETER 0-

500V(DIRECT)[email protected] No.

1.00

252

VOLTMETER 0-500V,PTR-

[email protected] No.

1.00

253

KW METER 3P,4W,CTR-1A,90-

[email protected] No.

1.00

254

KWH METER

3P,4W,DEGITAL,LEAST COUNT-

[email protected]

No.

1.00

255

FREQUENCY METER 230AC, 45-

[email protected] No.

1.00

256

Terminal connector on 216 kv

kv LA to suit single moose

[email protected]

No.

1.00

257

Terminal connector (through)on

216 kv kv LA to suit single

moose [email protected].

1.00

258

Terminal Connector on 132 Kv

Wave trap to suit single moose

ACSR (Top Terminal)@810.0No.

1.00

259

Expension type terminal

connector on 245 kv CB to suit

4" EH IPS AL [email protected].

4.00

260

Sliding(through) type terminal

connector on 245 kv centre

break isolator to suit 4" EH IPS

AL [email protected]

No.

1.00

Page 21: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

261

Rigid type terminal connector

on 245 kv isolator to suit 4" EH

IPS AL [email protected].

0.00

262

Expension type terminal

connector on 245 kv centre

break isolator to suit 4" EH IPS

AL [email protected]

No.

2.00

263

Terminal connector on 245 kv

centre break isolator to suit

single moose ACSR with 250

mm sub conductor spacing

@810.0

No.

1.00

264

Terminal connector suitable for

4"EH IPS AL Tube on main way

& single moose ACSR on branch

way @2430

No.

1.00

265

Expension type terminal

connector suitable for 4"EH IPS

AL Tube for tandem

[email protected]

No.

2.00

266

Sliding(through) type terminal

connector suitable for 4"EH IPS

AL Tube for tandem

[email protected]

No.

1.00

267

Terminal connector on 245 kv

tandem isolator to suit single

moose ACSR with 250 mm sub

conductor [email protected]

No.

3.00

268

parallel graove clamp to suit

single moose ACSR

[email protected]

No.

3.00

269

Sliding(through) type terminal

connector on 220 kv BPI to suit

4" Eh IPS AL [email protected].

3.00

270

Expension type terminal

connector on 220 kv BPI to suit

4" Eh IPS AL [email protected].

1.00

271

Corona bell suitable for 4"EH

IPS AL Tube @ 1530.0No.

3.00

272

Connector for 220 kV Circuit

Breaker @ 1935.0No.

4.00

273

Interconnector between single

moose ACSR to 4"AL

[email protected]

No.

4.00

Page 22: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

274

Single moose Through Clamp

assambly @ 5940.0No.

1.00

275

Terminal Connector on 145 kv

CVT to suit single mooose ACSR

@ 810.0

No.

1.00

276

Terminal Connector on 132 Kv

Wave trap to suit single moose

ACSR (Top Terminal) @ 810.0No.

1.00

277

Expension type Terminal

connector on 145 kv CB to suit

3" EH IPS AL Tube @ 4680.0No.

2.00

278

Rigid type terminal connector

on 145 kv isolator to suit 3" IPS

AL Tube @ 1764.0No.

6.00

279

Corona Bell suitable for 3" EH

IPS AL Tube @ 1044.0No.

3.00

280

Terminal Connector on 145 kv

isolator to suit single mooose

ACSR @ 810.0

No.

1.00

281

Interconnector between 3"EH

IPS AL tube & Single moose

ACSR @ 2070.0

No.

2.00

282

Extension type terminal

connector suitable for 3"EH IPS

AL Tube for tandem isolator @

4680.0

No.

2.00

283

Sliding (through) type terminal

connector suitable for 3"EH IPS

AL Tube for tandem isolator @

1980.0

No.

1.00

284

Terminal Connector on 245 kv

tandem isolator to suit single

moose ACSR @ 810.0

No.

3.00

285

parallel grove clamp to suit

single mooose ACSR conductor

@ 1080.0

No.

3.00

286

Sliding (through) type terminal

connector on 132 kv BPI to suit

3"EH IPS AL Tube @ 1404.0No.

3.00

287

Terminal Connector on 132 kv

bushing of 220/132 &132/33 kv

transformer to suit single

moose ACSR @ 1170.0

No.

2.00

Page 23: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

288

T connector to suit single

moose ACSR on both and

branch way @ 1080.0

No.

6.00

289

Clamp for 132 KV CVT @ 1485.0No.

2.00

290

Terminal connector for 132 KV

Isolator suitable for single

moose ACSR @1288.22No

11.00

291

Clamp for 132 KV CT 800/400/1

A suitable for single moose

[email protected]

No.

1.00

292

Clamp for 132 KV Isolator

@2077.05No

6.00

293

Terminal Connector on 33Kv LA

suit twin moose ACSR @ 2340.0 No.

1.00

294

Terminal Connector (Through)

on 33Kv LA twin moose ACSR @

2340.0

No.

1.00

295

Terminal Connector on horn

Gap fuse to suit twin moose

ACSR with 250mm sub

conductor spacing @ 2340.0

No.

1.00

296

Terminal Connector on 33Kv PT

to suit twin moose ACSR with

250mm sub conductor spacing

@ 2340.0

No.

1.00

297

T-Connector on 33Kv Centre

break Islator to suit twin moose

ACSR with 250mm sub

conductor spacing @ 2340.0

No.

4.00

298

Terminal Connector on 33Kv

BPT to suit twin moose ACSR

with 250mm sub conductor

spacing @ 2160.0

No.

3.00

299

Terminal Connector to twin

moose ACSR on both branch

way @ 2160.0

No.

2.00

300

Terminal Connector to suit

Quard Moose ACSR on main

and twin moose ACSR on

branch way @ 4500.0

No.

8.00

301

Terminal Connector on 33Kv

bushing of 132/33Kv &33/.44Kv

Transformer to suit moose

ACSR @ 2700.0

No.

1.00

Page 24: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

302

E-204- Cleat Type Clamp @

117.0No.

19.00

303

Twine moose 250 mm sub

conductor spacing to single

ACSR panther clamp @2820.40No.

3.00

304

Terminal clamp 33 KV

(1600/800/1A) Suitable for

Twine moose ACSR with 250

mm Sub conductor spacing with

copper brush @3291.87

NO.

0.00

305

Terminal Clamp for 33 KV PT to suit

twine moose ACSR with 250 mm sub

conductor spacing @2454.4

No.

5.00

306

Terminal connector 33 KV 800/400/1

Amp. Suitable for twine moose ACSR

with 250 mm sub conductor spacing

@3280.4

No.

2.00

307

Terminal connector 33 KV CB to suit

twine moose ACSR with 250 mm sub

conductor spacing @2684.5

No.

2.00

308

old used and brunted clamps

,cable and other material

@40.0

Kg

40.00

309

Unused brunt melted Clamps

connector and aluminium

conductor Scrap@ 20.0Kg

60.00

310

Receive back faulty 220 KV

breaker (areava make) spring

operating mechanism

@25000.00

No.

1.00

311

Damege /faulty Charging motor

suitable for 33 KV ABB Make

circuit breaker @2500.00No.

3.00

312

faulty main two distance relay

P442 @1500 220 KV CB 83 No.

1.00

313

Old and Brunt and melted

clamp and connector Scrap

@20

Kg

10.00

314

Damage old battery cell 12 V 65

AHNo.

2.00

315

Receive back Faulty Bay Control

Unit.@2500No.

2.00

Page 25: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

316

faulty and brunt RXMD2

Relay(CVT Selection

Relay)@500.00

SET

1.00

317

Damage 2 Volt 300 AH (VRLA

type )Battery cell @100

No.

5.00

318

Damage 2 Volt 500 AH (VRLA

type )Battery cell @100

No.

5.00

319

Damage 132 KV CB Operating

mechanism @2500

No.

1.00

320

MCB 220 Volt DC 10 Amp. @

783.83No

2.00

321

center rotating Aluminium rod

assembly (blade) suitablefor PR Engg.

Make 33 KV DBCR Isolator with

copper contact strip current 800

[email protected]

No

10.00

322

Female contact (Jaw) suitable for PR

Engg. 33 KV DBCR Isolator with

copper contact finger with current

rating 800 Amp. @ 6584.4

set

5.00

323

center rotating Aluminium rod

assembly (blade) suitablefor PR Engg.

Make 33 KV DBCR Bus Isolator with

copper contact strip current 1600

[email protected]

No

4.00

324

Female contact (Jaw) suitable for PR

Engg. 33 KV DBCR Bus Isolator with

copper contact finger with current

rating 800 Amp. @ 7611.0

set

2.00

325

326

Terminal connector for 33 KV

isolator to suit twine moose

ACSR with 250 mm sub

conductor spacing @2922.63

No.

1.00

327

Phase failure relay variable

under and over voltage output

415 V AC ALVD2 @4534.30No.

2.00

328

air break contractor 30 Amp

@3391.40No.

4.00

329

Silca gel container suitable for

OLTC Tank of 80 MVA

T/[email protected]

No.

1.00

330

Three Phase 4 wire contractor

relay for Bay marshaling kiosk

440 volt 7 [email protected].

1.00

Page 26: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

331

Three pole Mccb 63 amp for

Bay marshaling [email protected] No.

2.00

332

single pole MCB 16 Amp. For

bay marshaling [email protected] No.

1.00

333

different type of gland @129.21No.

6.00

334

different type of cable

[email protected].

4.00

335

different type of terminal

blocks @105.32No.

33.00

336

Hooter for RTCC panel for

Transformer @ 1409.75No

1.00

337

Phase plate (Set of three)

@710.0SET

1.00

338

G.I. Nut/bolts in different

[email protected]

9.00

339 Bird Guard@ 710.0 SET 2.00

340 Pipe type Earthing 9110.0 No. 1.00

341

come along clamp automatic

type suitable for 7/10 SWG

earth wire upto intial sag

tension made up to dia casted

galvenized steel @ 13563.3

No. 4.00

342

Come along clamps bolted type

with four number G.I. nut/bolts

7/10 SWG earth wire @14528.0

No. 4.00

343

Copper sleeve for CT

[email protected].

2.00

344

Bimetal Relay with Single

Phasing [email protected]

No.

2.00

345

Phase failure Relay

[email protected].

1.00

346

Air Break Contactor(siemens

make) @1178.8No.

2.00

347 Silica [email protected] Kg 80.00

348 Silica Container No. 1.00

349 Timer Relay No 2.00

350 Indication lamp No 10.00

351 Charging motor 220V AC/DC No 6.00

352 Limit switch for charging motorNo

9.00

353 Anti-pumping relay No 9.00

354 Auxiliary switch (13NO+13NC)No

4.00

Page 27: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

355 Tripping spring assy.For:OHBNo

5.00

356 Philips lamp no. 22

357

Panel no 891/SD258 440V 3 Phase 4

wire 400 A switchgear A.C.Distribution

board of modern cons of mfg co.(P) Ltd

Delhi (old & Dismentled)

No.

358 Clamps and connector scrap Kg.

359 Copper cable scrape. Kg.

360 Old & used Bended tower Parts KG.

361 Wire Mesh Mtr.

362PVC insulated flexible multistanded

copper bond/wire of size 50 SqmmMtr.

363Different size of M.S. Angles & Flat

(old,Used & Rusted)MT

364 Old ,used & rusted wire mesh Kg.

365End termination Kit for 33 KV 240 Sqmm

Cable No.

366G.I. Hanger Suitable for 132 Kv Line

(ACSR Panther).No.

367 Tension Fitting For ACSR. Panther No.

368 Suspension Fitting suitable for line. No.

369

Dead End Clamps Complete ACSR

Panther.No.

370 Selector Switch different type. @1469.1No.

371

Different size of G.I. nut bolt with

washer. @292.64Kg.

372 Isolator clamps. @1177.64 No.

373 Lugs copper 2.5 m.m. No.

374

Contactor 415V ac 38 Amps. 440v with

auxliry. No.

375 Superior quality Grease. Kg.

376 Petroleum jelly. Kg.

377 Clamps For 33 Kv L.A. No.

378 HRC Fuse 10/16/32. No.

379 Old Cotton dhoti. No.

380 Starter of Tube light. No.

381 Pvc Tape (Red, Yellow, Blue, Black). No.

382 Limit Switch For 132 Kv C.B. No.

383 Antipumping Relay 110v. No.

384 MCB 16 A. No.

385 Contactor for 132 Kv C.B. No.

386 2.5 Sq.mm.Flexible wire. Roll.

387 Isolator 2P, 32A No.

388 Battery Terminal Cleaner. No.

389 Power Cabinet No.

390 T&C Switch No.

1 AA0A004001 ACSR Conductor Zebra Mtr. 7 10

2 AA0A005001 ACSR Conductor Panther Mtr. 935 30

3 AA1A101001 GI Earth Wire 7/9 SWG Mtr.

4 AA5A501004 IPS Aluminium Tube 4" Mtr.

5BB0B002001 Capacitor Cell- 552.50 KVAR 10.96 KV No

6 BB4B401001 NCT- 5/1Amp No. 1

7CC0C002008

PVC Control Cable - W/o Armoured-

10x2.5mmMtr 40

132 KV S/S Jaspur.

Page 28: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

8 CC0C002010 PVC Control Cable - 6x2.5mm Mtr

9

CC1C102002 Power Cable -440V LT - - 3.5x400

Sq. mmMtr 240

10

CC1C102010 Power Cable -440V LT - -

3.5x35Sq. mmMtr

11

CC1C102010 Power Cable -440V LT - -

3.5x70Sq. mmMtr 190

12

CC2C201007 Control Cable- Armoured- - 6Cx2.5

Sq. MMtr

80

13CC2C201009

Control Cable- Armoured- - 4Cx2.5 Sq.

MMtr 193

14

CC2C201011 Control Cable- Armoured- - 2Cx2.5

Sq. MMtr 380

15 CC4C401001 HF Cable -75 Ohm HP CABLE- Mtr 242.17

16 FF2F207021 Template D Type for 220KV Double Circuit MT

17 FF2F207029 Template A Type for 132KV Double Circuit MT

18 FF2F207031 Template B Type for 132KV Double Circuit MT

19 FF2F207033 Template C Type for 132KV Double Circuit MT

20 FF3F302001 Tower Parts- GI MT

21 FF7F702005 MS Flat- 32x6mm MT 0.009

22GG0G001003

Maintenance material CRC 400 ML

Bottel No

23HH0H002002

Line Isolator 220 KV Motorized with

Earth Switch No

24HH0H003001 Line Isolator 132 KV with Earth switch No

25 HH5H502001 220 KV Isolater Spare Fixed contact Set

26

27HH5H503001

220 KV Isolater Spare Isolator Rotating

Assembly No

28HH5H506002

220 KV Isolater Spare Switch 220V Limit

Switch for Motorized IsolatorsSet

29HH6H601001

132 KV Isolater Spare Jaws Female

contact 1250 AmpNo

30HH6H602001

132 KV Isolater Spare Blade Male

contactNo

31

HH8H803001

33 KV Isolater Spare Isolator Rotating

Assembly Motorized operating

mechanism with earth link operation

box

No

32

HH8H803002

33 KV Isolater Spare Isolator Rotating

Assembly Motorized operating

mechanism for Isolator

No.

33 HH9H901007 Isolator Clamp Twin moose No

34 HH9H901008 Isolator Clamp Single moose No

35 HH9H901023 Isolator Clamp Terminal Pads No.

36 II0I001001 Disc Insulator 160 KN Porceline No

37 II0I002001 Disc Insulator 120 KN Porceline No 52

38 II0I003001 Disc Insulator 90 KN No

39 II0I004001 Disc Insulator 70 KN No 55

40 II1I102004 PG Clamp Moose- Panther No

41 II1I104001 PG Clamp Zebra- Zebra No. 33

42 II1I104002 PG Clamp Zebra- Panther Mtr 15

43 II1I105001 PG Clamp Panther- Panther No. 12

44 II2I202001 C-wedge Clamp Moose- Moose No

45 II2I204001 C-wedge Clamp Zebra- Zebra No. 32

46 II2I204002 C-wedge Clamp Zebra- Panther No. 9

47 II2I205001 C-wedge Clamp Panther- Panther No. 18

48 II3I302001 T-Connector Moose- Moose No

Page 29: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

49 II5I501003 Mid Span Joint Zebra No

50 II5I501004 Mid Span Joint Panther No 20

51 II5I502003 Repair Sleeve Zebra No

52 II5I502004 Repair Sleeve Panther No 20

53 II5I503004 Vibration Dampher Panther No 20

54 II7I704003 Spacers Quard Moose No

55 II7I704004 Spacers Twin Moose No

56 II8I801004 Single Tension Fitting Zebra No 1

57 II8I801005 Single Tension Fitting Panther No

58 II8I802002 Double Tension Fitting Moose No

59 II8I803001 Quard Tension Fitting Moose No

60 II8I804005 Single Suspension Fitting Panther No

61JJ0J003001 Single pole Circuit Breaker 132KV SF-6 No

62JJ1J102003

Circuit Breaker Sapres 220KV Trip Coil

AssemblyNo

63JJ1J102004

Circuit Breaker Sapres 220KV Closing

CoilNo

64JJ1J102005

Circuit Breaker Sapres 220KV 220V

Closing CoilNo

65JJ1J102006

Circuit Breaker Sapres 220KV Closing

Coil AssemblyNo

66JJ1J102008 Circuit Breaker Sapres 220KV Poles No

67JJ1J102009

Circuit Breaker Sapres 220KV Moving

Contact/ Male ContactSet

68JJ1J102011 Circuit Breaker Sapres 220KV O Ring Set

69JJ1J102014

Circuit Breaker Sapres 220KV Gas

pressure SwitchSet

70

JJ1J102020Circuit Breaker Sapres 220KV

Complete Spring oprating Mechanism

71JJ1J103001

Circuit Breaker Sapres 132KV 220V DC

Trip CoilNo

72JJ1J103002

Circuit Breaker Sapres 132KV 220V DC

Trip Coil AssemblyNo

73JJ1J103003

Circuit Breaker Sapres 132KV 220V DC

Closing CoilNo

74JJ1J103004

Circuit Breaker Sapres 132KV 220V DC

Closing Coil AssemblyNo

75JJ1J103005

Circuit Breaker Sapres 132KV 110V DC

Trip CoilNo 1

76JJ1J103007

Circuit Breaker Sapres 132KV Moving

Contact/ Male Contact

77JJ1J103008

Circuit Breaker Sapres 132KV Fixed /

Female/ Copper Contact

78JJ1J103010

Circuit Breaker Sapres 132KV Spring

Charging MotorNo

79JJ1J105034

Circuit Breaker Sapres 33KV Charging

MotorsNo

80 KK0K002001 Lighting Arrestor 220 KV No

81 KK0K003001 Lighting Arrestor 132 KV No 2 1 2

82 KK0K005001 Lighting Arrestor 33 KV No 3

83

KK4K302001

Bus Post Insulator (without corona ring)

with creepage distance of 6125 mm. -

245 kV

No

84

KK4K302002

Bus Post Insulator (without corona ring)

with creepage distance of 3625 mm. -

145 kV

No

Set

Page 30: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

85 KK4K401005 Post Insulator 33KV No. 202

86LL0L001003

HPSV Lighting Material HPSV Lighting

Complete 400WNo.

87 LL0L003003 HPSV Lighting Material Lamp 400W No.

88LL0L004003 HPSV Lighting Material Ignitor 400W No.

89LL3L303002 Flurocent Light Flurocent Tube 36W No.

90 LL4L402005 C.F.L. C.F.L Lamp 27 Watt No. 29

91 LL4L402007 C.F.L. C.F.L Lamp 23 Watt No. 34

92

MM3M307007

Digital Meter - KWH (Energy meter) -

Energy meter 3Phase 3wire 110V 5A

50HZ KWH Secure meter LTD old&usedNo. 1

93 VV2V204015

Terminal connector for bushing. HV-40

MVANo 8

94 VV2V204016

Terminal connector for bushing. LV-40

MVANo 1

95 VV6V605006

Current Transformer 33 KV 800-

400/1A 3 core No 2 3

96VV6V605008

Current Transformer 33 KV

400/200/1A 3 core Accuracy 0.2No 1

97VV6V605013

Current Transformer 33 KV 200-

100/1Amp 3 Core No 2 4

98VV8V803002

PT (Potential Transformer) 145 KV PT 3

core with one 0.2 accuracyNo

99VV8V805001

PT (Potential Transformer) PT 3-phase

33KV/110 Volt -No 1

100VV8V805002

PT (Potential Transformer) PT 1-phase,

33KV/110 Volt -No 2

101 VV8V810002 CVT CVT 220 KV/110 Volt - No

102

VV8V810003 CVT CVT - CVT 132 KV/110 Volt - 145kv No 2 3

103

Panel no 891/SD258 440V 3 Phase 4

wire 400 A switchgear A.C.Distribution

board of modern cons of mfg co.(P) Ltd

Delhi (old & Dismentled)

No. 1

104 Clamps and connector scrap Kg. 58

105 Copper cable scrape. Kg. 25

106 Old & used Bended tower Parts KG. 400

107 Wire Mesh Mtr. 100

108PVC insulated flexible multistanded

copper bond/wire of size 50 SqmmMtr. 25

109Different size of M.S. Angles & Flat

(old,Used & Rusted)MT 1

110 Old ,used & rusted wire mesh Kg. 200

111End termination Kit for 33 KV 240 Sqmm

Cable No. 2

112G.I. Hanger Suitable for 132 Kv Line

(ACSR Panther).No. 18

113 Tension Fitting For ACSR. Panther No. 12

114 Suspension Fitting suitable for line. No. 3

115

Dead End Clamps Complete ACSR

Panther.No. 15

116 Selector Switch different type. @1469.1No. 2

117

Different size of G.I. nut bolt with

washer. @292.64Kg. 7

118 Isolator clamps. @1177.64 No. 3

119 Lugs copper 2.5 m.m. No. 18

120

Contactor 415V ac 38 Amps. 440v with

auxliry. No. 1

Page 31: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

121 Superior quality Grease. Kg. 4

122 Petroleum jelly. Kg. 4

123 Clamps For 33 Kv L.A. No. 2

124 HRC Fuse 10/16/32. No. 10

125 Old Cotton dhoti. No. 30

126 Starter of Tube light. No. 45

127 Pvc Tape (Red, Yellow, Blue, Black). No. 5

128 Limit Switch For 132 Kv C.B. No. 2

129 Antipumping Relay 110v. No. 1

130 MCB 16 A. No. 1

131 Contactor for 132 Kv C.B. No. 2

132 2.5 Sq.mm.Flexible wire. Roll. 2

133 Isolator 2P, 32A No. 3

134 Battery Terminal Cleaner. No. 1

135 Power Cabinet No. 8

136 T&C Switch No. 2

1 AA0A002001ACSR Conductor Moose Mtr. 200

2 Singale Tension Fitting For ACSR Panther ConductorNo 19

3 Tension Clamp for Earth Wire7/10 SWGNo 6

4 Tension Clamp for Earth Wire No 1

5 AA0A005001ACSR Conductor Panther Mtr. 1786

6 Multifunction Laser Get Black & White PrinterOf HP Make No. 2

7 Desktop Computer No. 2

8 Cell phone Nokia 1600 1

9 Samsung Mobile No. 1

10 UPS 600 VA Numeric No. 2

11 Printer HP LI M1202DW No 1

12 Printer HP LI M1128FW MFP No 1

13DD0D00100

1

Mcafee AntiviresNo.

… 1

14DD0D00100

2

Internal Modem 56KbpsNo.

1

15DD0D00100

3

M.S.Office 2007 Standard MOLP without

Media (Software)No.

1

16DD0D00200

1

Desktop Computer make HCLNo.

1

17DD0D00200

2

TFT Monitor 39.5cm. Make HCLNo.

1

18DD0D00200

3

UPS 1KVA 168 VAH make UnilineNo.

1

19DD0D00200

4

Bilingual Key BoardNo.

1

20DD0D00200

5

Combo DriveNo.

1

21DD0D00400

3 Printer Samsung No. … 1

22 FF1F103001 Double Circuit 132KV A Type Kg 3300

23 FF1F103006 Double Circuit 132KV B Type Mt 10.1

24 FF2F207031 Template B Type for 132KV Double Circuit MT 0.936

25 Density Monitor Switch No 1

26 Rotatarg Bearing For 132 kv Isolater No 3

27 FF4F401023 Galvanised Nuts & Bolts-16x50 mm / 16 X 2"/5/8" Kg 25

28 FF4F401024 Galvanised Nuts & Bolts-16x40 mm kg 30

33HH8H80100233 KV Isolater Spare Jaws &

Blade1250 Amp. No 1

132 KV Substation Sitarganj and ELDECO Sitarganj

Page 32: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

34 HH8H80100433 KV Isolater Jaws 1600 Amp. No

35 33 KV Isolater Blade 1600 Amp. No

3633 KV Isolater Spare Jaws & Blade

800 Amp. 2

37 II0I002001 Disc Insulator 120 KN Porceline No 108

38 II0I004001 Disc Insulator 70 KN No 23

39 II1I105001 PG Clamp Panther- Panther No. 1

40 II1I104001 PG Clamp Zebra- Zebra No 6

41 II2I204001 C-wedge Clamp Zebra- Zebra No 6

42 II2I205001 C-wedge Clamp Panther- Panther No 9

43PG Clamp Zebra- panther Conductor No

3

44 PG Clamp Panther- Dog No …

45 T Clamp Panther- Panther No …..

4733KV Circuit breaker Clamp For

panther conductorNo

8

48 33 KV C.T. Clamp for panther conductor No …

49 33 KV isolator Clamp for panther conductorNo 3

50 33kv PT Clamp for panther conductor No 4

5133 KV circut breaker Clamp for

tarantula conductorNo

5

52 33KV CT Clamp for tarntula conductor No ..

53 33kv isolator Clamp for tarmtula conductorNo 3

54

33kv one side 13 mm grove with cu

sleeve ct clamp other side panther

conductor

No

5

55Station Transformer clamp for dog

conductorNo

56 132 kv circut breaker Clamp for panther conductorNo 3

57 132 kv CT Clamp for panther conductor No 1

58132 KV Isoleter Terminal Connector For

Zebra ConductorNo

4

59 132 KV isolater Clamp For panther conductor No 3

60 132 KV Circuit breaker Clamp for Zebra conductorNo 2

61 132KV CT Clamp for Zebra Conductor No 1

62 132 KV isoletor Clamp for zebra conductor No 3

63 132 KV PT Clamp for zebra conductor No 2

64 Armrd rod for panther Set 1

65 Mid Span joint for panther conductor No 1

66 250Watt HPSV Lamp Screw Typereputed makeNo 4

67 Copper Blast For 250 Watt HPSV Lamp No 2

68 Ignator for 250 Watt HPSV Lamp No 1

69 Capacitor Suitable for 250 Watt HPSV Lamp No 1

70 HPSV Lamp Holder Screw Type No 1

71 LED Lamp OF 18 Watt No 1

72 Double Pole 32 A AC MCB No 1

73 LT Cubical .5*.5m No 2

74 LT Cubical 900*750*500mm No 1

7540 MVA T/F HV Side Bushing For Zebra

conductor

7640 MVA T/F NEWTRAL Bushing

Connector for Falt 4 (N+B)No. 2

77II5I501004 40 MVA T/F LV Side Bushing clamp For

Tarntula conductorNo

3

7840 MVA T/F LV Side Bushing PG clamp

For Tarntula conductorNo

3

7940 MVA T/F HV Side Bushing PG clamp

For Zebra conductorNo

4

Page 33: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

81 33 KV VCB BHEL Make No 8

82 Circuit Breaker 132KV Closing

/Tripping Coil(ABB) 3

83 Circuit Breaker Control Switch No 4

84 132 KV Feeder Trip Coil (CGL)

BreakerNo

2

85 133 KV Feeder Close Coil (CGL)

BreakerNo

2

86 Spring Charge Moter(CGL Breaker )No

2

87 SF-6 Gas kg 20

88 JJ8J802001 Empty Cylinder No 2

89KK0K00300

1

Lighting Arrestor 132 KV old &

UsedNo. 0

90KK0K00500

1

Lighting Arrestor 33 KV Old & Used,

NewNo

13

91KK4K40100

3

Post Insulator Solid core - 145 KV

No 3

92Godrej Fitting Cabinet 4 DWR, MODEL-

STV FXDM4086NO

93 Godrej Table -102 NO

94 Computer Table C-3 NO

95 Godrej Center Plece 530-7 E NO

96 Godrej Chair PCH-7002 D NO

97 Godrej Chair CH-1007 NO

98 Godrej PCH-9103 R NO

99 Godrej Trident Stool ST-2 NO

100PP0P001003 Godrej Storewel KD Plain (4Shelves)

No.

101 Godrej VIA3STR arm PMBI NO

102 Godrej Lounger Sofa L42,2Str NO

103 Godrej Slimline with Locker NO

104Godrej Vienna King Bed mod

STBEDMFK079NO

105 Godrej Chair PCH-7003D NO

106 Water Cooler with Aqua flow NO

107Shock Treatment Chart & Artificial

Respriratory SystemSet

108 Rubber Mat in control room Mtr

109 One Set Each of D/E & Ring Spanners Set

110 Fist Aid Box Set

111 Danger board Set

112 Hand Gloves Set

113 Book Care Rack No.

114 Almera Store Well No. 3

115 Book Case Rack No. 3

116 Spanner D/E & Ring (one Set Each) Set 2

117 Open Jaw Spanner No. 7

118 Ring Spanner No. 2

119 Screw Driver No. 3

120 Double Ended Tubler box No. 1

121PP0P002001

Adjustable WrinchNo. 2

122PP0P002002

Flat nose plierNo. 1

123PP0P002004

Normal PlierNo. 1

Page 34: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

124 Half Round File No. 1

125 Ball Pin Hammer No. 2

126 Hack Saw No. 1

127 Cold chisel No. 1

128 Gasket Pinch Set 1

129 Gas Filling equipment No. 1

130 SF6 Gas Evacuating Device No. 1

131 Contact Resistance Meter No. 1

132Mono Block Pump 1 HP, 1Φ,240 V, AC

Khaitan Make No. 1

133 Vaccume cleaner No. 1

134 Godrej Table T-104 No. 1

135Godrej Regency Mid back Chair PCH -7002D No.

2

136 Godrej Visitor Chair CH-1007 No. 8

137 Godrej Storwel Plain Big With 4 Shelves No. 7

138 Godrej 4 Drawer Vertical Filling Cabinet No. 7

139 Godrej Coumputer Table Companion C-2 No. 4

140 Godrej Revolving Chair Without Arms PCH7031No. 4

141 Godrej Table T-09 No. 1

142 Godrej Table T-08 No. 3

143 Godrej Premium Visitor Chair PCH-7003 No. 3

144 Table with Three Drawer No. 2

145 Big Table Model V2 No. 1

146 Dining Table Model V1 No. 1

147 Chair CH-1007 No. 2

148 Easy Chair PCH 50017 No. 1

149 Dining Chair PCH 7112 No. 4

150 Chair PCH 9003 No. 1

151 Teak wood Bed (Single) No. 2

152 Table T-9 No. 1

153 Center Table sonata No. 1

154 Table WT 711 No. 1

155 Primary Injection Set No. 1

156 5 KV Moterised Magger No. … 1

157 1 KV Maggar No. … 1

158Voltas Water Cooler With Aqua Flow

Storage( EYREAFOREDS) No. … 1

159 UPS 1 KVA 168 VAH Make Uniline No. … 1

160 KEY Board No. … 1

161 Earth Resistance Meter No. … 1

162PP0P003004

StoolNo. … 1

163 T&C Equipments

164PP0P004001 Megger 5 KV

No.

165 Megger 1 KV No.

166 Multimeter No.

167 Tong Tester No.

168 Oil Testing Set 80 KV Motorized No.

169 Gas Leakage Tester No.

170 Contact Resistance Meter No.

171QQ1Q10500

1

Sub-Station Security Wire Mesh Kg 330

172 Earth Wire Kg

173TT1T10103

0

Genral Registers-Log Sheet

No 22

174 VV3V301007 Oil Empty Oil Drums No 82

Page 35: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

175VV4V404001

Transformer Spare PRV Pressure

Relief VentNo

2

176 VV3V302001 Bucholz Relay GOR 1 (25 NB) No

177VV6V603007

Current Transformer 145KV

200/100/1A 3 core Accuracy 0.2 No. 1 8

178VV6V605005

Current Transformer 33 KV 800-

400/1A 3 core Accuracy 0.2No

1 1

179 VV8V805002 PT (Potential Transformer) PT 1-

phase, 33KV/110 Volt -No

180VV8V805001 PT (Potential Transformer) PT 3-

phase 33KV/110 Volt -

NO

1

181 Iron Packing Case Scrop M. Ton 0.225

182 Al Scrop Kg 1.6

183 1200mm Celling Fans (Defective& Sceap)NO 3

184 33KV PT (Old& Used) NO 2

185

Copper bond flexible copper rope dia

10mm,5 cm long crimped with two

no copper lug of 18 mm dia bore. NO …

186 Petroleum jelly in white colour of

first quality kg …

187

Copper bond flexible copper rope dia

9mm,25 mm long crimped with two

no copper lug of 18 mm dia bore. NO ….

188 40Watt Florescent Tube Light (ISI) NO 10

189 Starter For 40 Watt Tube Light NO 12

190 40 Watt Copper/ Electronic Ballast

Suitable for 40 Watt Tube Light NO

191 FF4F401023 Galvanised Nuts & Bolts-16x50 mm / 16 X 2"/5/8" Kg 50

192 FF4F401024 Galvanised Nuts & Bolts-16x40 mm kg

193 HH8H80100233 KV Isolater Spare Jaws &

Blade1250 Amp. No

194 HH8H80100433 KV Isolater Jaws 1600 Amp. No 7

195 33 KV Isolater Blade 1600 Amp. No 7

196 33 KV Isolater Spare Jaws & Blade

800 Amp.

197 II0I002001 Disc Insulator 120 KN Porceline No

198 II0I004001 Disc Insulator 70 KN No

199 II1I105001 PG Clamp Panther- Panther No. 12

200 II1I104001 PG Clamp Zebra- Zebra No

201 II2I204001 C-wedge Clamp Zebra- Zebra No 6

202 II2I205001 C-wedge Clamp Panther- Panther No 0

203 PG Clamp Zebra- panther Conductor No

204 PG Clamp Panther- Dog No 66

205 T Clamp Panther- Panther No 50

206 33KV Circuit breaker Clamp For

panther conductorNo

10

207 33 KV C.T. Clamp for panther conductor No 10

208 33 KV isolator Clamp for panther conductorNo 10

209 33kv PT Clamp for panther conductor No 6

210 33 KV circut breaker Clamp for

tarantula conductorNo

8

211 33KV CT Clamp for tarntula conductor No 6

212 33kv isolator Clamp for tarmtula conductorNo 6

Page 36: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

213 33kv one side 13 mm grove with cu

sleeve ct clamp other side panther

conductor

No

214 Station Transformer clamp for dog

conductorNo

3

215 132 kv circut breaker Clamp for panther conductorNo

216 132 kv CT Clamp for panther conductor No

217 132 KV Isoleter Terminal Connector For

Zebra ConductorNo

218 132 KV isolater Clamp For panther conductor No

219 132 KV Circuit breaker Clamp for Zebra conductorNo 6

220 132KV CT Clamp for Zebra Conductor No 8

221 132 KV isoletor Clamp for zebra conductor No 8

222 132 KV PT Clamp for zebra conductor No 6

223 Armrd rod for panther Set

224 Mid Span joint for panther conductor No

225 250Watt HPSV Lamp Screw Typereputed makeNo 0

226 Copper Blast For 250 Watt HPSV Lamp No 0

227 Ignator for 250 Watt HPSV Lamp No 0

228Capacitor Suitable for 250 Watt HPSV Lamp No 0

229 HPSV Lamp Holder Screw Type No 0

230 LED Lamp OF 18 Watt No

231 Double Pole 32 A AC MCB No

232 LT Cubical .5*.5m No

233 LT Cubical 900*750*500mm No

234 40 MVA T/F HV Side Bushing For Zebra

conductor2

235 40 MVA T/F NEWTRAL Bushing

Connector for Falt 4 (N+B)No.

236 II5I501004 40 MVA T/F LV Side Bushing clamp For

Tarntula conductorNo

2

237 40 MVA T/F LV Side Bushing PG clamp

For Tarntula conductorNo

238 40 MVA T/F HV Side Bushing PG clamp

For Zebra conductorNo

239 33 KV VCB BHEL Make No

240 Circuit Breaker 132KV Closing

/Tripping Coil(ABB)

241 Circuit Breaker Control Switch No

242 132 KV Feeder Trip Coil (CGL)

BreakerNo

243 133 KV Feeder Close Coil (CGL)

BreakerNo

244 Spring Charge Moter(CGL Breaker )No

245 SF-6 Gas kg 5

246 JJ8J802001 Empty Cylinder No 1

247 KK0K00300

1

Lighting Arrestor 132 KV old &

UsedNo.

1 3

248 KK0K00500

1

Lighting Arrestor 33 KV Old & Used,

NewNo

1 2

249 KK4K40100

3

Post Insulator Solid core - 145 KV

No

250 Godrej Fitting Cabinet 4 DWR, MODEL-

STV FXDM4086NO

1

251 Godrej Table -102 NO 2

252 Computer Table C-3 NO 1

253 Godrej Center Plece 530-7 E NO 1

Page 37: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

254 Godrej Chair PCH-7002 D NO 1

255 Godrej Chair CH-1007 NO 5

256 Godrej PCH-9103 R NO 2

257 Godrej Trident Stool ST-2 NO 3

258 PP0P001003 Godrej Storewel KD Plain (4Shelves)No.

2

259 Godrej VIA3STR arm PMBI NO 1

260 Godrej Lounger Sofa L42,2Str NO 1

261 Godrej Slimline with Locker NO 1

262 Godrej Vienna King Bed mod

STBEDMFK079NO

1

263 Godrej Chair PCH-7003D NO 2

264 Water Cooler with Aqua flow NO 1

265 Shock Treatment Chart & Artificial

Respriratory SystemSet

2

266 Rubber Mat in control room Mtr 20

267One Set Each of D/E & Ring Spanners Set

1

268 Fist Aid Box Set 1

269 Danger board Set 1

270 Hand Gloves Set 1

271 Book Care Rack No. 2

272 Almera Store Well No.

273 Book Case Rack No.

274 Spanner D/E & Ring (one Set Each) Set

275 Open Jaw Spanner No.

276 Ring Spanner No.

277 Screw Driver No.

278 Double Ended Tubler box No.

279 PP0P002001Adjustable Wrinch

No.

280 PP0P002002Flat nose plier

No.

281 PP0P002004Normal Plier

No.

282 Half Round File No.

283 Ball Pin Hammer No.

284 Hack Saw No.

285 Cold chisel No.

286 Gasket Pinch Set

287 Gas Filling equipment No.

288 SF6 Gas Evacuating Device No.

289 Contact Resistance Meter No.

290 Mono Block Pump 1 HP, 1Φ,240 V, AC

Khaitan Make No.

291 Vaccume cleaner No.

292 Godrej Table T-104 No.

293 Godrej Regency Mid back Chair PCH -7002D No.

294 Godrej Visitor Chair CH-1007 No.

295 Godrej Storwel Plain Big With 4 Shelves No.

296 Godrej 4 Drawer Vertical Filling Cabinet No.

297 Godrej Coumputer Table Companion C-2 No.

298 Godrej Revolving Chair Without Arms PCH7031No.

299 Godrej Table T-09 No.

300 Godrej Table T-08 No.

301 Godrej Premium Visitor Chair PCH-7003 No.

302 Table with Three Drawer No.

303 Big Table Model V2 No.

Page 38: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

304 Dining Table Model V1 No.

305 Chair CH-1007 No.

306 Easy Chair PCH 50017 No.

307 Dining Chair PCH 7112 No.

308 Chair PCH 9003 No.

309 Teak wood Bed (Single) No.

310 Table T-9 No.

311 Center Table sonata No.

312 Table WT 711 No.

313 Primary Injection Set No. 0

314 5 KV Moterised Magger No. 0

315 1 KV Maggar No. 0

316 Voltas Water Cooler With Aqua Flow

Storage( EYREAFOREDS) No.0

317 UPS 1 KVA 168 VAH Make Uniline No. 0

318 KEY Board No. 0

319 Earth Resistance Meter No. 0

320 PP0P003004Stool

No.

0

321 T&C Equipments

322 PP0P004001 Megger 5 KVNo.

1

323 Megger 1 KV No. 1

324 Multimeter No. 1

325 Tong Tester No. 1

326 Oil Testing Set 80 KV Motorized No. 1

327 Gas Leakage Tester No. 1

328 Contact Resistance Meter No. 1

329 QQ1Q10500

1

Sub-Station Security Wire Mesh Kg 0

330 Earth Wire Kg 13515

331 TT1T10103

0

Genral Registers-Log Sheet

No

5

332 VV3V301007 Oil Empty Oil Drums No

333

VV4V404001

Transformer Spare PRV Pressure

Relief VentNo

334 VV3V302001 Bucholz Relay GOR 1 (25 NB) No 1

335

VV6V603007

Current Transformer 145KV

200/100/1A 3 core Accuracy 0.2 No.

0

336

VV6V605005

Current Transformer 33 KV 800-

400/1A 3 core Accuracy 0.2No

2

337VV8V805002

PT (Potential Transformer) PT 1-

phase, 33KV/110 Volt -No

2

338 VV8V805001 PT (Potential Transformer) PT 3-

phase 33KV/110 Volt -

NO 0

339 Iron Packing Case Scrop M. Ton 0

340 Al Scrop Kg 0

341 1200mm Celling Fans (Defective& Sceap)NO

342 33KV PT (Old& Used) NO

343

Copper bond flexible copper rope dia

10mm,5 cm long crimped with two

no copper lug of 18 mm dia bore. NO 5

344 Petroleum jelly in white colour of

first quality kg 15

Page 39: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

345

Copper bond flexible copper rope dia

9mm,25 mm long crimped with two

no copper lug of 18 mm dia bore. NO 19

346 40Watt Florescent Tube Light (ISI) NO

347 Starter For 40 Watt Tube Light NO

348 40 Watt Copper/ Electronic Ballast

Suitable for 40 Watt Tube Light NO

1

AA0A00500

1

ACSR PANTHER CONDUCTOR IN PIECES km 0.558 1.132 1

2

AA0A00500

1

ACSR PANTHER CONDUCTOR DAMAGED km 0.85

3

AA1A10200

1

swg earth wire 7/10 KG 150

4

CC0C002010 CONTROL CABLE 6*2.5 MM^2 mtr 295

5

CC0C002008 CONTROL CABLE 10*2.5 MM^2 mtr 270

6 FF2F201015 NUTS AND BOLTS OFF SIZE kg 40

7 FF4F401068 Galvanzed/Zinc coated Nut & Bolts KG 95

8 FF0F003017 Galvianized Tower pieces X Type NO 1

9FF3F301037 66 KV BUS ISOLATOR STRUCTURE OLD

AND USED

No 1

10 FF4F401068 NUTS AND BOLTS OFF SIZE

11 FF4F401068 GI Nut & Bolt

KG 50

12 FF7F701004

MS ROUND 36mm MT 0.286

13 FF7F702003

Earthing Flat 50 x 6 mm KG 500

14 FF9F904003

copper bond nut bolt NO 10

15 33 KV EARHT LINK (O&U) NO 1

16

HH6H60300

1

132 KV ISOLATOR EARTH SWITCH (PSDF) NO 1

17

HH6H60200

1

132 KV BLADE OLD AND USED No 12

18

HH6H60100

1

132 KV JAW OLD U/S No 18

19

HH0H00300

1

132KV ISOLATOR(O&U) WITH EARTH

LINK

NO 2

20

HH1H10300

1

132KV ISOLATOR(O&U) WITHOUT

EARTH LINK

NO 1

21

HH9H90101

6

33 KV Isolator ConnectorNO

1

22

HH9H90101

6

33 kv isolator clampNO

10

23 II0I004001 132 KV DISK INSULATOR No 10

24II8I804005 suspension fitting for panther conductor No. 3

25II8I801004 bolted type tension fitting for ACSR

zebra coductor

MTR 6

26II8I801005 Single Tension fitting 120N for panther

conductor

NO 4

27II5I501001 Mid span joint for panther conductor NO 14

132KV S/S Bhowali.

Page 40: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

28II5I501001 Vibration Damper for panther conductor NO 12

29 II5I501001 Repair sleeve panther conductor NO 17

30 II1I105001 PG Clamp panther conductor NO 25 6

31 II801010 Tension clamp swg earth wire NO 5

32II8I801005 Single tension fitting complete with

arching horn

NO 1

33 II1I105001 PG Clamp Panther- Panther NO 1

34II1I105001 PG Clamp panther to panther (3 bolted

type )

NO 10

35 JJ8J801001 SF6 GAS KG 1

36 JJ1J103005 CLOSING COIL FOR 132 KV ABB CB No 2

37 JJ1J103005 TRIPPING COIL FOR 132 KV ABB CB No 2

38 JJ1J103005 Tripping coil 132 KV CGL CB NO 2

39 JJ1J103005 CLOSING COIL 132 KV CGL CB NO 2

40 JJ1J103005 Tripping coil 132 kv ABB CB (New) NO 2

41 JJ1J103005 CLOSING COIL 132 KV ABB CB(New) NO 2

42 JJ1J105005 Tripping coil 33 KV CGL CB NO 2

43 JJ1J105007 CLOSING COIL 33 KV CGL CB NO 2

44 JJ1J105007 CLOSING COIL 33KV ABB CB NO 2

45 JJ1J103037 Limit switch 132 kv ABB CB NO 2

46 JJ2J201007 Limit switch 33 kv ABB CB NO 2

47 JJ1J125001 CONTRACTOR 25 A 3 PHASE NO 4

48 JJ1J125001 CONTRACTOR 63 A 3 PHASE NO 4

49 JJ0J004003 66 KV MOCB BHEL (DEFF) No 2

50 JJ0J005005 33 KV BOCB BHEL (DEFF) No 3

51 JJ0J005005 33 KV BOCB WITH OIL (DEFF) No 3

52 JJ0J003003 132 KV MOCB BHEL MAKE (DIFF)NO No 2

53 JJOJ005004 33 KV BHEL CB (DAMAGED) NO 1

54 JJ0J003001 132 KV SF 6 CB(O&U) NO 1

55 JJOJ005004 33 KV CB VCB (O&U) NO 2

56 JJ0J005002 33 KV CB SF6 (O&U) no 1

57JJOJ005004 33 KV CB BHEL MAKE (VCB) OLD/USED NO 1

58 JJ4J402009 33 KV Circuit Breaker Connector NO 4

59

KK0K005001 30 KV LA NO 3

60

KK4K40100

6 22 KV POST ISOLATORNO 14

61

KK4K401003 145 kv bus post insulator solid core type NO 3

62

KK0K003001 132 KV LA(O&U) NO 7

63

KK0K005001 33 KV LA(O&U) NO 6

64

KK4K401003 132 KV POST INSULATOR(OLD/USED) NO 3

65

MM3M3060

03

Energy meter 3P4W( old & diff) NO 1

66

MM0M0590

01

RELAY ABB MAKE MODEL NO REL

511(O/U)

NO 1

67

MM0M0390

01

RELAY MAKE SIEMENS MODEL NO

SIPROTEC 7UT61(O/U)

NO 1

68

MM3M3060

03

ENERGY METER 3P4W MAKE L&T(O/U)

TYPE ER 300P

NO 2

69

MM3M3060

03

ENERGY METER 3P3W MAKE SECURE

(OLD & USDE)

NO 1

Page 41: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

70

NN0N00300

1

132 KV CONTROL LINE PANEL

(WITHOUT RELAY AND ENERGY

METER)(O/U)

NO 1

71

NN1N10300

1

132 KV RELAY LINE PANEL (WITHOUT

RELAY AND ENERGY METER)(O/U)

NO 1

72

NN3N30300

1

15 MVA T/F CONTROL AND RELAY

PANEL (WITHOUT RELAY AND ENERGY

METER)(O/U)

NO 1

73

NN2N20500

2

33 KV CONTROL AND RELAY TRIPLE

FEDDER PANEL (WITHOUT RELAY AND

ENERGY METER)(O/U)

NO 1

74 SS3S301020 HRC FUSE 10 AMP NO 11

75 SS3S301019 HRC FUSE 16 AMP NO 12

76 SS3S301013 HRC FUSE 25 AMP NO 16

77 SS3S301010 HRC FUSE 32 AMP NO 16

78 SS3S301008 HRC FUSE 63 AMP NO 18

79

VV4V406001buccholz relay

NO1

80 vv6v606007 11 KV CT 200/100/5 A DEFF No 4

81

VV6V606004 11 KV CT 600/300/5 A PROTACTION No 3

82

VV6V605013 33 KV CT 200/100/1 A ( BURNET) No 4

83

VV6V606005 11 KV CT 400/200/5 A PROTECTION No 2

84

VV6V604002 66 KV CT 200/100/1 A (DEFF) No 1

85

VV8V806001 11 KV PT REPAIRED No 1

86

VV6V606007 11 KV CT 200/100/5 A PROTECTION No 3

87

VV6V605013 33 KV CT (o/ u & ) 0.5 NO 3

88

VV8V810003 132 KV CVT (USED & OK) NO 3

89

VV6V603004 132 KV CT Kapco make(400/200/1A) NO 1

90

VV3V301001 TRANSFORMET OIL OLD AND USED Ltr 2850

91

VV3V301001 T/F OIL CARBONISED Ltr 2707

92

VV3V301007 EMPTY OIL DRUM No 20 12

93

VV7V701019 132 kv CT Connector NO 6

94

VV3V301005 OIL SAMPLING CONTAINER 2 LIT KG 6

95

VV2V201003 NITRIL GASKET8MM SPM 1.3

96

YY4Y403001 48 KV 300 AH BATTERY CHARGER (DEFF) No 1

97

YY0Y002005 110 V EXCIDE BATTERY CELL 55 U/S set 1

1 AA0A002001ACSR Conductor Moose Mtr. 345 283.5

2 AA0A004001ACSR Conductor Zebra Mtr. 13

220 KV S/S Pantnagar

Page 42: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

3 AA0A005001ACSR Conductor Panther Mtr. 23915

4 AA1A102001GI Earth Wire 7/10 SWG Mtr. 127

5 BB002002 Capacitor Cell- 331kvar, 6.9kv No. 1

6

CC0C00200

8

PVC Control Cable - W/o Armoured-

10x2.5mm Mtr 703

7

CC0C00201

1

PVC Control Cable - W/o Armoured-

4x2.5mm Mtr 921

8

CC0C00201

3

PVC Control Cable - W/o Armoured-

2x2.5mm Mtr 1000

9

CC1C10201

2

Power Cable - 440V LT - - 3.5x35

Sq. mm Mtr 1079

10 CC4C401001 HF Cable -75 Ohm HP CABLE- Mtr 555

11 FF2F206006 Stub for 132KV D/c B Type MT 0.399

12 FF2F207046 Template Non GI (A,B,C Type) MT 7.903

13 FF3F301002 Strcture- Pipe MT 1.05

14 FF3F301028 Strcture-HT MT 5.112

15 FF3F301029 Strcture-MT MT 7.813

16 FF3F302001 Tower Parts- GI MT 19.157

17 FF4F401002 Galvanised Nuts & Bolts-30x00 mm MT 0.169

18 FF4F402025 HOT dipped Galvanised-16x45 mm/ (5/8"x1*3/4No. 615

19 FF4F402027 HOT dipped Galvanised-16x35 mm No. 650

20 FF9F904003 Copper -Bond Round No 24

21

HH0H002001Line Isolator 220 KV with Earth

switch No. 1

22 HH6H602001

132 KV Isolater Spare Blade Male

contact No. 1

23 HH6H602002

132 KV Isolater Spare Blade Female

Contact No. 1

24 HH8H801004

33 KV Isolater Spare Jaws 800 Amp.

No. 0

25 HH8H802003

33 KV Isolater Spare Blade 800

Amp. No. 2

26 HH9H901002

Isolator Clamp Rigid terminal

connector 4" AL tube No. 2

27 HH9H901003

Isolator Clamp Through type for 4”

IPS Al tube No. 10

28 HH9H901007 Isolator Clamp Twin moose No. 2

29

33 KV Isolater Spare Blade 1600

Amp. No. 6

30

33 KV Isolater Spare Jaws 1600

Amp. No. 6

31 II0I001001 Disc Insulator 160 KN Porceline No. 15

32 II0I002001 Disc Insulator 120 KN Porceline No. 1060

33 II0I004001 Disc Insulator 70 KN No. 20 401

34 II2I202001 C-wedge Clamp Moose- Moose No. 40

35 II2I204001 C-wedge Clamp Zebra- Zebra No. 31

36 II2I204002 C-wedge Clamp Zebra- Panther No. 45

37 II2I205001 C-wedge Clamp Panther- Panther No. 60

38 II4I402001

Earth Wire Tension Clamp 7/9 SWG

No. 17

39 II4I403001

Earth Wire Suspension Clamp 7/9

SWG No. 62

40 II5I501001

MS Joint/ Repair Sleeve/ Vibration

Damper Mid Span Joint Moose No. 20

41 II5I501003 Mid Span Joint Zebra No. 50

42 II5I501004 Mid Span Joint Panther No. 46

43 II5I501008 Mid Span Joint 7/9 SWG No. 15

44 II5I501009 Mid Span Joint 7/10 SWG No. 15

Page 43: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

45 II5I502001 Repair Sleeve Moose No. 15

46 II5I502003 Repair Sleeve Zebra No. 20

47 II5I502004 Repair Sleeve Panther No. 11

48 II5I503004 Vibration Damper Panther No. 100

49 II5I503008 Vibration Damper 7/9 SWG No. 30

50 II5I503009 Vibration Damper 7/10 SWG No. 30

51 II6I601001

Armour Rod/ Jumpher Cone/ Plate/

Bird Guard Armour Rod Moose Set 3

52 II6I601004 Armour Rod Panther No. 19

53 II801009 Single Tension Fitting 7/9 SWG No. 25

54 II801010 Single Tension Fitting 7/10 SWG No. 10

55 II8I802005 Double Tension Fitting Panther No. 1

56

II8I804010 Single Suspension Fitting 7/10 SWG

No. 10

57 JJ0J005002

Circuit Breaker 33KV 110V DC

SF-6 No. 1

58 JJ1J105001

Circuit Breaker Sapres 33KV 220V

DC Trip Coil No. 1

59 JJ1J105005

Circuit Breaker Sapres 33KV 110V

DC Trip Coil No 1

60 JJ2J201010

Circuit Breaker Auxiliary switch

Density moniter switch No 1

61 JJ3J301001

Control panel Spares Relay

Thermal Overload realy No 8

62 JJ4J401003 Circuit Breaker Connector moose No 5

63 JJ4J401004

Circuit Breaker Connector Twin

moose No 5

64

KK0K00200

1

Lighting Arrestor 220 KV

No. 6 15

65

KK0K00300

1

Lighting Arrestor 132 KV

No. 0 3

66

KK0K00500

1

Lighting Arrestor 33 KV

No. 1

67

KK4K30200

1

Bus Post Insulator (without corona

ring) with creepage distance of 6125

mm. - 245 kV No. 12

68 LL6L603001

Lighting Spares Lighting Junction

Box. No. 7

69 MM3M303012

Digital Meter - MW Meter - MW

Meter Type 3 Phase 4 wire 50-0-50

MW CTR 200/1A PTR132KV /110

V. Aux Supply 110 V DC No. 1

70

PP0P001001 Steel Almera

No. 8

71

PP0P001002 Steel Rack

No. 1

72

PP0P002001 chair PCH 9003

No. 7

73

PP0P002003 Easy Chair PCN 500/T

No. 2

74

PP0P002005 Computer Chair

No. 1

75

PP0P003001 Table T-8

No. 4

76

PP0P003002 Godrej Table T-9

No. 3

77

PP0P003004 Office Table 1800X900X760

No. 1

Page 44: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

78

PP0P003005 Computer Table

No. 2

79

PP0P003006 Book Care Rack

No. 6

80

AC and other electrical/Electranics

items

81

PP0P005001 Voltas water cooler with aquaflow

eyreaforebs storage capacity 20 ltr. No. 2

82

PP0P005002 AC Votas 1.5 Ton

No. 1

83 Rope 1" Kg 65

84 Rope 1/2" Kg 112.5

85 Tong tester No. 1

86

Screw driver Large (Standard

Quality) No. 1

87

screw driver medium (Standard

Quality) No. 4

88 Nose Plier (Standard Quality) No. 2

89

Vaccum cleaner with blower and

suction No. 1

90

Visitor chairs without arm (Godrej

make) No. 8

91 Portable SF6 Gas Leak Detector. No. 1

92

Hydrolic Jack with gauge & house

pipe No. 4

93 Open Jaw spanner No. 6

94 double end tubeler box No. 1

95 Adjestable wriench 200 mm Long No. 1

96 Pipe wrinch 450 mm Long No. 2

97 Gasket punch set No. 1

98 Flat file No. 1

99 Lather mallet No. 2

100 Cold chiesel No. 1

101 Stool No. 1

102 Teak wood bed (singel) No. 2

103 Table S1070 No. 1

104 Desktop PC No. 2

105 TFT Monitor No. 2

106 UPS 1 KVA No. 2

107 Laser Printer No. 1

108 Laser Fax No. 1

109 Trafer 10T No. 1

110 Single pully block No. 3

111 Double pully block No. 3

112 Four Pully block No. 2

113 Al Lader 15 Feet No. 1

114 Al Lader 24 Feet No. 1

115 Printer Samsung No. 1

116 Chair PCH5002T No. 5

117 Chair PCH 1004 No. 4

118 Store well Plain Godrej No. 1

119 Broad band modem No. 1

120 Al Tower lader No. 1

121

30 Watt LED rechargeable portable

light No. 1

122 Desert cooler with Stand No. 5

123 Karbon Cell Phone (A101) No. 1

124 Micromax Cell Phone (A60) No. 1

Page 45: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

125 Samsung Cell Phone (grand) No. 1

126 Dektop Computer System No. 2

127 Printer HP pro No. 1

128 UPS 600VA No. 1

129 SS1S104006

Contactor 415V AC 240 Volt A.C.

Coils including frame for coil for 3ɸ

Power Contactor IC-65a & IC-65a/4

No. 7

130 TT2T101032

General Stationary-PVC Tape

coloured No. 10

131 VV1V102001

Transformer Bushing -220/132 KV

HV-160 MVA No 4

132 VV1V102002

Transformer Bushing -220/132 KV

LV-160 MVA No 2

133 VV1V104001

Transformer Bushing -132/33KV

HV-80 MVA No 2

134 VV1V104002

Transformer Bushing -132/33KV

LV-80 MVA No 2

135 VV1V104003

Transformer Bushing -132/33KV

Neutral-80 MVA No 2

136

VV2V201001Transformer Gasket, Breather, Silica

gel & Connector Gasket Nitril gasket

10mm

Set

2

137 VV3V301001 Oil Transformer Oil Ltr. 124

138 VV3V301005 Oil Oil sample Bottle 2Ltr No. 3

139 VV3V301006 Oil Oil sample Bottle 1Ltr No. 4

140 VV3V301007 Oil Empty Oil Drums No. 1171

141 VV3V302002 Bucholz Relay GOR 2 (50 NB) No. 1

142 VV4V401001

Transformer Spare Oil Temperature

indicator Meter (0-120 0C ) No. 1

143 VV4V402001

Transformer Spare Winding

Temperature indicator Winding

Temperature indicator Meter No. 5

144 VV4V403001

Transformer Spare Level Gauge

DIAL OIL LEVEL GAUGE

145 VV4V403002

Transformer Spare Level Gauge

Magnetic oil Level Guage No 3

146 VV4V404001

Transformer Spare PRV Pressure

Relief Vent No 4

147 VV6V602001

Current Transformer 245KV

1600/800/1A 5 core Accuracy 0.2 No 1

148 VV6V602004

Current Transformer 245KV

800/400/200/1A 5 core Accuracy 0.2

No

3 3

149 VV6V603001

Current Transformer 145KV

800/400/1 A 5 core Accuracy 0.2 No 2

150 VV6V603002

Current Transformer 145KV

800/400/1 A 3 core Accuracy 0.2 No 1

151 VV6V605001

Current Transformer 33 KV

1600/800/1A 5 Core Accuracy 0.2 No 5

152 VV6V605004

Current Transformer 33 KV

800/400/1 A 5 Core Accuracy 0.2 No 2

153 VV6V605005

Current Transformer 33 KV 800-

400/1A 3 core Accuracy 0.2

No

15

154 VV6V605007

Current Transformer 33 KV

400/200/1A 4 core Accuracy 0.2 No 1

155 VV7V701013

Current Transformer Terminal

Connectors Single Moose ACSR No 2

Page 46: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

156 VV7V701014

Current Transformer Terminal

Connectors Twin Moose ACSR No 4

157 VV7V701029

Current Transformer Terminal

Connectors 36kV Terminal

connector(Rigid type) for 4” IPS Al

tube No 2

158 VV8V805001

PT (Potential Transformer) PT 3-

phase 33KV/110 Volt - No. 3

159 VV8V805002

PT (Potential Transformer) PT 1-

phase, 33KV/110 Volt - No. 10 8

160 VV8V810002 CVT CVT 220 KV/110 Volt - No. 1

161 VV8V810003

CVT CVT - CVT 132 KV/110 Volt -

145kv No. 6

162

YY1Y10100

4

Battery Cell 2 V 400AH lead acid No. 3

1 AA0A001001 ACSR ConductorTarantula Mtr.

2 AA0A004001 ACSR Conductor Zebra Mtr. 80

3 AA0A005001 ACSR Conductor Panther Mtr. 188 150

4 AA0A008001 ACSR Conductor Dog Mtr. 2095 120

5 AA0A011001 ACSR Conductor Rabbit Mtr. 1760

6CC0C002011

PVC Control Cable - W/o Armoured-

4x2.5mm Mtr

7CC0C002013

PVC Control Cable - W/o Armoured-

2x2.5mm Mtr 305

8CC1C102009

Power Cable -440V LT - - 3.5x95 Sq.

mmMtr

9CC1C102011

Power Cable -440V LT - - 3.5x50 Sq.

mmMtr

10CC2C201004

Control Cable- Armoured- - 3.5Cx35

Sq. mmMtr

11CC2C201006

Control Cable- Armoured- - 10Cx2.5

Sq. MMtr 160

12CC2C201007

Control Cable- Armoured- - 6Cx2.5 Sq.

MMtr

13CC2C201009

Control Cable- Armoured- - 4Cx2.5 Sq.

MMtr

14CC2C201011

Control Cable- Armoured- - 2Cx2.5 Sq.

MMtr 430

15 CC3C303003 XLPE cable - 33KV -- 300 Sq. mm Mtr

16 CC3C303005 XLPE cable - 33KV -- 70 Sq. mm Mtr

17 CC8C801008 -GI Cable Tray- Turfer gatted 6" Nos

18 CC8C801009 -GI Cable Tray- Turfer gatted 5" Nos

19 CC9C903001 -Plastic ferule a-z, 0-9- Nos

20DD0D001001 Mcafee Antivires No. 2

21DD0D001002 Internal Modem 56Kbps No. 2

22DD0D002001 Desktop Computer make HCL No. 2

23DD0D002002 TFT Monitor 39.5cm. Make HCL No. 2

24DD0D002003 UPS 1KVA 168 VAH make Uniline No. 2

25DD0D002004 Bilingual Key Guard No. 2

132 KV O&M Division, Kashipur

Page 47: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

26DD0D002005 Combo Drive No. 2

27DD0D004003

Multifunction printer model No. Scx

4521 F make SamsungNo. 1

28FF2F203024 Stub for 132KV S/c CCM type tower Kg

29 FF2F207036 Template A Type for 132KV Single Circuit No 1

30 FF2F207038 Template B Type for 132KV Single Circuit M.T 0.80

31 FF2F207040 Template C Type for 132KV Single Circuit M.T 1.008

32 FF3F301005 Strcture- ALP Kg

33 FF3F301008 Strcture- ATM Kg

34 FF3F301009 Strcture- AXM Kg

35 FF3F301010 Strcture- BBL No 4

36 FF3F301013 Strcture-BCT No 4 4

37 FF3F301014 Strcture- BTM Kg

38 FF3F301019 Strcture- CCM Kg

39 FF3F301040 Strcture-Main lattice 33 KV Gantries Kg

40 FF3F301042 Strcture-33KV Isolator MT 0.63

41 FF3F302001 Tower Parts- GI MT 7.193 0.205

42FF4F401026

Galvanised Nuts & Bolts-16x38

mm/5/8" X 1*1/2Kg

43 FF4F401068 Galvanised Nuts & Bolts-Off Size Kg

44 FF7F701003 MS Earthing rod- 40 mm Dia MT 0.44

45GG0G001003

Maintenance material CRC 400 ML

BottelNo 6

46GG0G001013 Maintenance material Plastic compound

47HH0H005002

Line Isolator 33 KV Double break with

Earth switchNo 2 9

48 HH1H103001 Bus Isolator 132 KV No 6

49 HH1H105001 Bus Isolator 33 KV No 25

50 HH9H901013 Isolator Clamp Twin Zebra

51 HH9H901016 Isolator Clamp singlePanter

52 II0I001001 Disc Insulator 160 KN Porceline No 20

53 II0I002001 Disc Insulator 120 KN Porceline No 16

54 II0I004001 Disc Insulator 70 KN No 719

55 II0I005001 Disc Insulator 22KN No

56 II1I104001 PG Clamp Zebra- Zebra No

57 II1I104002 PG Clamp Zebra- Panther No 5

58 II1I105001 PG Clamp Panther- Panther No. 40

59 II1I108001 PG Clamp Dog- Dog

60 II2I203002 C-wedge Clamp Deer- Zebra

61 II2I203003 C-wedge Clamp Deer- Panther

62 II2I204001 C-wedge Clamp Zebra- Zebra No 0

63 II2I204002 C-wedge Clamp Zebra- Panther

64 II2I205001 C-wedge Clamp Panther- Panther No 3

65

II3I306001 T-Connector Special Panther-

Panther

No 25

66 II5I501004 Mid Span Joint Panther No 5

67 II5I501009 Mid Span Joint 7/10 SWG No 5

68 II5I502004 Repair Sleeve Panther No 8

69 II5I503003 Hanger ACSR Panther

70 II8I801005 Single Tension Fitting Panther No 3

71 II8I802005 Double Tension Fitting Panther Set 9

72 II8I804005 Single Suspension Fitting Panther No 47

73 II5I503004 Vibration Damper Panther No 82

74 II6I601004 Armour Rod Panther Set

75 II6I604001 Bird Guard No

76 II801010 Single Tension Fitting 7/10 SWG Nos

Page 48: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

77

II8I805005 Double Suspension Fitting PantherNo 5

78 II8I807004 Single Gun Fitting Zebra No 0

79 II8I807005 Single Gun Fitting Panther No 6

80 JJ0J003001 Circuit Breaker 132KV SF-6 No

81 JJ0J003003 Circuit Breaker 132KV MOCB No 6

82JJ0J005002

Circuit Breaker 33KV 110V DC SF-

6No 2

83JJ0J005004

Circuit Breaker 33KV 110V DC

VCBNo 10

84 JJ0J005005 Circuit Breaker 33KV BOCB No 7

85 JJ0J005006 Circuit Breaker 33KV MOCB No 7

86JJ1J103005

Circuit Breaker Sapres 132KV 110V

DC Trip CoilNo 6 5

87JJ1J103007

Circuit Breaker Sapres 132KV 110V

DC 110V Closing CoilNo 6

88JJ1J105005

Circuit Breaker Sapres 33KV 110V

DC Trip CoilNo 5

89JJ1J105006

Circuit Breaker Sapres 33KV 110V

DC Trip Coil AssemblyNo

90JJ1J105007

Circuit Breaker Sapres 33KV 110V

DC Closing CoilNo 2

91JJ1J105008

Circuit Breaker Sapres 33KV 110V

DC Closing Coil AssemblyNo

92JJ1J105009

Circuit Breaker Sapres 33KV Moving

ContactNo

93JJ1J105012

Circuit Breaker Sapres 33KV Male

contactNo

94JJ1J105022 Circuit Breaker Sapres 33KV I-bolt No

95JJ1J105034

Circuit Breaker Sapres 33KV

Charging MotorsNo

96JJ2J201005

Circuit Breaker Auxiliary switch

LOCAL/Remote SwitchNo 2

97JJ2J202008

Circuit Breaker Auxiliary Contact (3

NO+ 2 NC)No 3

98 JJ3J301003 Relay Anti pumping Relay-8Pin No 6

99JJ4J401010

Circuit Breaker Connector Twin

PantherNo

100JJ6J601043

Circuit Breaker Accessories Bushing

insulatorNo

101JJ7J701043

OCB Sapres - 11KV - female main

Alimated finger contact No 35

102JJ7J701045

OCB Sapres - 11KV - male main

Alimated finger contact No 51

103 JJ8J801001 SF-6 Gas Kg 8

104 JJ8J802001 Empty Cylinder No 8

105KK0K003001 Lighting Arrestor 132 KV No

106KK0K004001 Lighting Arrestor 66 KV No

107KK0K005001 Lighting Arrestor 33 KV No 2

108KK1K001007 Surge Counter 132 KV No 1

109KK4K401002

Post Insulator Poly cone Insulator -

132KV No

110KK4K401005 Post Insulator 33KV No

Page 49: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

111LL0L003004 HPSV Lighting Material Lamp 250W No 0

112LL0L004004 HPSV Lighting Material Ignitor 250W No

113LL0L005004

HPSV Lighting Material Capacitor

250WNo

114LL0L008001

HPSV Lighting Material HPSV Lamp

fifting No

115LL0L009001

HPSV Lighting Material HPSV Lamp

Holder No

116

LL1L107001

Mercury Lighting Material Accessories

Covers and reflectors for various Sodium

Vapour/Mercury vapour lamps

No

117LL2L202004

Hallogen Lighting Material Copper

Ballast 250W/Choke 250 WNo

118LL3L301005

Flurocent Light Flurocent Light fitting

1x36 WNo 9

119 LL3L302001 Flurocent Light Choke 40W No 4

120 LL3L303001 Flurocent Light Flurocent Tube 40W No

121 LL4L401002 C.F.L. Complete fitting. 85W No

122 LL4L402006 C.F.L. C.F.L Lamp 25 watt No

123LL6L601002

Lighting Spares Flexible PVC coated

copper wire 16 sq mm(black colour)Mtr 50

124LL6L601003

Lighting Spares Flexible PVC coated

copper wire 04 sq mmMtr 30

125LL6L606001

Lighting Spares ACDB for Control

Room Light No 1

126 LL6L611002 Lighting Spares Sockets 5Amp No 1

127 LL7L701002 Exhaust Fan 1 phase No

128

MM0M00100

1

Relay - Distance Relay - Distance

protection relay Type YTG No 1

129

MM0M00400

1

Relay - Instant earth fault relay - Instant

earth fault relay Type-CAG No 3

130

MM0M00500

2

Relay - O/C & E/F Relay - O/C ,E/F

relay (Inverse Type) CDG.No 5

131

MM0M00600

1

Relay - Neutral Impedence Replica -

Neutral Imped Replica Type YTG-31. No 1

132

MM0M00700

1

Relay - Definite time relay - Definite

time relay Type Type - VTT. No 1

133

MM0M00900

1

Relay - Auxiliary relay - Auxiliary relay

Type VAA .No 23

134MM0M050001

Relay - Fuse Failure Relay - CVT Fuse

Failure RelayNo 3

135

MM1M111003

Miscellaneous Panel Spare - Semaphore -

Electronic semaphore indication-having

Red & Green LED 110 volt DC

No 3

136MM2M204016

Analog Meter - KWH Meter - KWH

meter 3x100 A No

137

MM2M205014

Analog Meter - MVAR Meter - Analog

MVAR meter range CTR-400/1A (120-0-

120) MW

No

138MM2M206001

Analog Meter - Power factor meter -

400/1A with S/ switch No

139

MM3M301002

Digital Meter - Volt Meter - Volt Meter

A C -range 0-150 KV PTR 132KV/110

V. Aux Supply 110 V DC

No 3

Page 50: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

140

MM3M301003

Digital Meter - Volt Meter - Volt Meter

(Rating 132000/110Volt) Auxiliary

Supply 110V DC

No

141MM3M301006

Digital Meter - Volt Meter - Volt Meter

132 KVNo

142

MM3M301011

Digital Meter - Volt Meter - Volt Meter

(Rating 33000/110Volt) Auxiliary

Supply 110V DC

No 3

143

MM3M302005

Digital Meter - Ampere Meter - Ampere

Meter for LT, 600/5 A, Aux supply 230

V AC

No 0

144

MM3M302006Digital Meter - Ampere Meter - Ampere

Meter size 150x150mm,CTR 400/1ANo

145

MM3M302013Digital Meter - Ampere Meter - Ampere

Meter size 150x150mm,CTR 200/1ANo

146

MM3M302023

Digital Meter - Ampere Meter - Ampere

Meter A C -range 0-500 A

(programmable) Aux Supply 110 V DC

No 17

147

MM3M303007

Digital Meter - MW Meter - MW Meter

Range - 150 to + 150 CTR-400/1A PTR-

132 KV/110V

No

148

MM3M303012

Digital Meter - MW Meter - MW Meter

Type 3 Phase 4 wire 50-0-50 MW CTR

200/1A PTR132KV /110 V. Aux Supply

110 V DC

No 4

149NN2N206001 C&R PANEL - 11 KV - No 3

150NN3N303001 T/F C&R PANEL - 132/33 KV - No

151

NN9N906001

VCB PANELS -

INCOMING/BUSCOUPLER PANEL-

11 KV - V.C.B. incoming panel-11KV,

630 A, 350 MVA -make C.G.L.

No 2

152 PP0P001001 Steel Almera No 1

153 PP0P001002 Steel Rack No

154 PP0P003005 Computer Table No

155 PP0P004002 Oil Testing Set (defective) No

156 PP0P004003 2500 Volt Motor Insulation Testor No 1

157 PP0P004004 Centrifusing Machine No 1

158 PP0P006001 Single Sleeve Pulley Block No

159

PP0P006008 Rubber Gum Boots No

160

PP0P007001 Helmat No 6

161QQ1Q101003

Sub-Station Security Pale Fencing

Upright 2.4mtrNo

162QQ1Q104001 Sub-Station Security G I wire mesh No

163 SS4S404003 MCB 230V AC Single Pole 16 Amp No 3

164 SS4S404005 MCB 230V AC Single Pole 10 Amp No

165 SS4S405003 MCB 415 AC Tripple Pole 32 Amp. No

166 SS4S405006 MCB 415 AC Tripple Pole 6 Amp. No 1

167VV0V005002 Transformer 33/0.4 KV - 250 KVA No 0

168VV1V105010

Transformer Bushing -33/11 KV HV-

5 MVANo 2

Page 51: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

169VV1V105011

Transformer Bushing -33/11 KV LV-

5 MVANo 2

170VV2V202001

Silica Gel Breather Assembly for

conservator No 0

171VV2V202002

Silica Gel Breather Assembly for

OLTCNo

172 VV2V203008 Silica Gel Blue crystal Kg 0

173VV2V204020

Terminal connector for bushing. LV-20

MVANo

174 VV3V301002 Oil Transformer Oil, Carbonised Ltr

175 VV3V301007 Oil Empty Oil Drums No

176 VV3V301008 Oil Empty Drum 45 Gallon No 25

177 VV3V303001 Oil Surge Relay For NGEF No

178VV4V401004

Transformer Spare Oil Temperature

indicator type 100 mm dia No

179

VV4V402001

Transformer Spare Winding Temperature

indicator Winding Temperature indicator

Meter

No 2

180VV4V403002

Transformer Spare Level Gauge

Magnetic oil Level GuageNo

181VV4V405008

Transformer Spare Exhaust fan Single

Phase 14 inchNo

182 VV5V502015 Filtering machine Spare Oil tray No

183VV6V603001

Current Transformer 145KV 800/400/1

A 5 core Accuracy 0.2No

184VV6V603003

Current Transformer 145KV

400/200/1A 5 core Accuracy 0.2No 2

185VV6V606004 Current Transformer 11 KV 600/5 A No 9

186VV6V606005 Current Transformer 11 KV 400/5 A No 4 4

187VV6V606006 Current Transformer 11 KV 300/5 A No 4 1

188VV6V606007

Current Transformer 11 KV 200/100/5

ANo 1

189YY0Y002005

Battery Set 110 Volt 300AH, acid

tubular battery setSet 1

190YY0Y003008

Battery Set 48 Volt 200AH, acid

tubeler battery setNo 2

191YY1Y101005 Battery Cell 2 V 300AH lead acid No

192YY1Y101006

Battery Cell 2 V 200AH tublar lead

acid No 74

193YY2Y211001 Battery Spares Empty Acid Cans No

194YY6Y602023

Battery Charger Spares 110V DC

Control Card No

195YY6Y603027

Battery Charger Spares 48V DC

Thyristor/diode No

196 Series Reactor 6.6 KVA No. 2

197 Dif. Control Panel for Capacitor No. 2

198

Steel Bracket for Cap. Bank Cell(used

and rusted ) No. 18

199 Damaged Series Reactor No. 2

200

33 KV VCB (DIF.)'BHEL' of Capacitor

Bank No. 1

201 Damaged capacitor cell No 1

Page 52: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

202

3.56,36 KVAR,7.3 KV,50A,22 micro

farad single phase 50 Hz internal fuse

,APP type HV capacitor unit

"MAGNEWIN" make

No 1

203 Defective capacitor cell No 7

204

M Seal Joint kit for 11 KV 3X70 mm2

Cable No. 1

205PVC Cable 3,1/2 Core in Pes Mtr. 55

206(Old and used) 11 KV Cable Mtr. 110

207

Cable XLPE 3X120mm2 Armored Poly

CabMtr. 125

208

33 KV Heat shrink Cable Termination

Kit for 120 mm2 XLPE Cable outdoorNo. 2

209

33 KV Heat shrink Cable Termination

Kit for 120 mm2 XLPE Cable indoorNo. 2

210

Heat Shrink O/D Termination Kit for

135 mm2 XLPE Cable No. 2

211

Heat Shrink I/D Termination Kit for 135

mm2 XLPE Cable No. 2

212

Heat Shrink O/D Termination Kit for

185 mm2 (PILCA) No. 2

213

Heat Shrink I/D Termination Kit for 185

mm2 (PILCA) No. 1

214

I/D Termination kit for 70 mm2 XLPE

CableNo. 4

215

O/D Termination kit for 70 mm2 XLPE

CableNo. 4

216

Damaged 11 KV XLPE Cable 300 mm2

in PCSMtr. 80

217

11 KV XLPE Cable box 3X400 mm2

(indoor)No. 2

218

Heat shrink cable termination kit for

3X300 mm2 XLPE cable (outdoor)No 2

219

Heat shrink cable termination kit for

3X400 mm2 XLPE cable (outdoor)No 0

220

Heat shrink cable termination kit for

3X300 mm2 XLPE cable straight

through joint (outdoor)

No 1

221 Bracket for auxiliary Contact No. 1

222 Fencing Angle Kg. 150

223 Steel Tubular Pole No. 2

224 G.I Nut & Bolt 3/4X5/8 Kg. 34.5

225 Fabricated Support for fencing No. 8

226 PN Structure No. 2

227 Rusted, Bended Structure Parts Kg. 210

228 Hanger for 'A' type Tower No. 10

229 Tension fitting for Dog No. 15

230

Hot dip Galvanized structure column and

beamKg. 810

231

Copper bonds strips 100X6X500 mm of

standard quality with all eyelets at both

ends

No 1

232 Porcelain Insulator No. 3

233 33 KV Isolator Blade(damaged) No. 8

234 132 KV Isolator blade 'SMC' No. 3

Page 53: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

235Blade for 132 KV Isolator 800X SMC No. 6

236 Damaged 132 KV Isolator blade No. 4

237 132 KV Isolator Blade Old & used No. 3

238

Jaw assembly for 132 KV Isolator

complete with their connectorNo 11

239 132 KV Isolator Blade No 3

240

Supply of Male arm complete with

contact assembly for 145 KV centre

break type isolator, make Elpro

Nos 0

241

Supply of Female arm complete with

contact assembly for 145 KV centre

break type isolator, make Elpro

Nos 0

242

Male contact assembly suitable for

145 KV centre break type isolator,

make Elpro

Nos 0

243

Female contact assembly suitable

for145 KV centre break type isolator,

make Elpro

Nos 0

244

Terminal connectors for ACSR

panther conductor suitable for 145

KV centre break type isolator, make

Elpro

Nos 0

245 33 KV Post Insulator for Cap Bank No. 12

246 132 KV Pole only No. 1

247 132 KV porcelain insulator O.D Type No. 1

248 33 KV Post Insulator No. 3

249 Mid Spam Joint for Zebra No. 4

250 Insulator No. 78

251 Isolator clamps for Zebra No 0

252 132 KV Breaker Clamps No 1

253

Transformer clamps standard quality as

per sampleNo 5

254 Cup Spring No. 22

255 Fixed Contact for 'BHEL' MOCB No. 5

256 Male Contact for HEL BOCB No. 12

257 33 KV Pole Cap for 'BHEL' MOCB No. 1

258

Universal Motor of Charging Motor for

33 KV MOCBNo. 1

25933 KV Flange Collar for 'BHEL' MOCB No. 2

260

33 KV ABCB (Damaged with

compressor) No. 1

261

Damaged Male Contact for 'BHEL'

MOCBNo. 10

262 33 KV Flange Collar(Damaged) No. 8

263

Damaged Main Busing Rod of 11 KV

OCB No. 19

264Damaged Fix Contact for 'BHEL' MOCB No. 6

265 33 KV X.SS Zetpot No. 1

266

Exitingusing chamber for 33 KV BOCB

& MOCB, C-0.6, B-11.1 Kg. 12

267 Spring Leave No. 22

268 Closing Coil 110V No. 2

269Damaged Male Contact of 33 KV BOCB No. 6

270Damaged 33 KV Bushing of HEL OCB No. 3

Page 54: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

271

33 KV OCB HEL,

damaged,incomplete,irrepairable No. 1

272Exitingusing chamber for 33 KV MOCB No. 3

273 33 KV X-ss Zetpot (damaged) No. 5

274RepairdMale Contact for 33 KV MOCB No. 1

275 132 KV Extinguishing Chamber No. 2

276 Closing Coil, 24 V No. 1

277 Tripping Coil 24 V No. 1

27833 KV BKR Aliened Alstom damaged No. 1

279 Gas vent pipe for 132 KV MOCB No. 3

280 11 KV Control box for Biecco OCB No. 6

281KWH Meter, 3X400/1A 132 KV/110V No. 7

282 KWH Meter, 3X3X100/1A No. 2

283 KWH Meter, 200/5a, 11KV/110V No. 4

284 Def. KWH Meter No. 2

285 Damaged Electronic Energy Meter No. 1

286 KWH Meter 100/5A. 11 KV/110V No. 4

287 KWH Meter 3X3X600/5A No. 2

288 Datapro make Energy Meter No. 3

289

Def.Electronic Energy Meter Secure(old

and used) No. 4

290

Electronic Energy Meter with comm. &

cord No. 1

291(Old and used)Energy Meter 'Sangmo No. 2

292 Inst. Time U/V Relay No. 2

293 YCO 289229 D & 289209 D No. 2

294 Auto Reclose Relay No. 1

29511 KV XLPE Cable 3X400mm2 Mtr. 125

296 Aux Relay type 21 ZG 8002 CM No. 1

297 CAG/VA No. 1

298

Electronic TVM 132 KV/110-/1A'(Old

and used)No. 1

299

Percentage differential relay type DDT-

32 No. 1

300 110 Volt DC Relay For Breaker No. 3

301

Auxiliary relay type VAJ model No.

VAJH13YF61B (old & used)No 2

302

Energy meter L&T 3P 4 Wire (old &

used)No 1

303

Directional o/c and E/F Numerical relay

(Defective)No 1

304

Energy meter Secure 3P3 Wire (old &

used)No 1

305

11 KV Protection relay (O/C&E/F) old

& usedSet 4

306 Limit Switch No. 2

307 Damaged 11 KV Bus Bar No. 8

308

11 KV 630A, 350 MVA, JV VCB Out

going Panel No. 5

309

PLCC Siemens Carrier Cabinet (Old and

used)No. 2

310

Pilfer proof Metering Cubicle Containing

33 KV CT & PT with necessary fitting

with ratio 60/1A

No. 1

Page 55: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

311

Pilfer proof Metering Cubicle Containing

33 KV CT & PT with necessary fitting

with ratio 30/1A

No. 1

312 Carrier Cabinet No. 1

313 3phase, 440 V. Starter No. 1

314 Switch 5 Amp ( Anchor) No 0

31533 KV PT/RVT (old used and rusted) No. 5

316 33 KV CT 400/200/1A (old and used) No. 1

317

33 KV Ring Type CT,

200/100/1A(Prot.)No. 3

318

33 KV Ring Type CT,

200/100/1A(Metering)No. 2

319

33 KV Ring Type CT,

800/400/1A(Metering)No. 4

320 Damaged 33 KV CT 200/100/1A No. 14

321 Oil Temperature Indicator No. 2

322 Tap Position Indicator No. 1

32333 KV CT 200/100/1A (old and used) No. 5

324 33KV CT 120/1A (old and used) No. 4

325 11 KV PT (Defective) No. 2

326 160KVA 11/0.4 KV Transformer No. 1

327 11 KV 100/50/5A CT No. 1

328 T/F Oil (old and used) Ltr. 900

329 Damaged 33 KV CT 800/400/1A No. 5

330 Damaged 33 KV CT 400/200/1A N No. 2

331 T/F Oil old used & dirty Ltr. 535

332 33 KV Bushing No. 1

333 Damaged 132 KV CT No. 1

334 Damaged 132 KV CT 800/400/1A No. 1

335 132 KV PT (defective) No. 3

336 132 KV CVT 'BB' or 'CGL' each No. 2

337 132 KV CT 200/100/1A No. 3

338 (Old and used& rusted)Voltage TF No. 3

339 11 KV CT O/ D Type (defective) No. 3

340 11 KV VCB 'CGL' (defective) No. 1

341 11 KV RVT (Old , used rusted) No. 1

342 33 KV CT 0.5/7.5MVA 400/1A ECE No. 2

343 33 KV PT 2.5 MVA No. 1

344132 KV CT 400/200/1A(Old and used) No. 0

345 33 KV CT 800/400/1A(Old and used) No. 1

346 250 KVA 11/0.4KV TF(defective) No. 1

347 11 KV Ring Type CT 200/5A No. 2

348 C T Jn, Box for 33 KV C T No. 2

349 145 KV CT 100/1A No. 2

350 33 KV CT 800/400/1A No. 1

351 P T Jn, box for 33 KV PT No. 4

352 Scrap of 33 KV CT 200/100/1A No. 1

353 (Old and used) 132 KV P T No. 1

354 (Old and used) 33 KV RVT No. 1

355

(Old and used, Defective)33 KV C T

800/400/1ANo. 1

356 T/F Oil (old, used ,dirty) Ltr. 200

357

33KV CT 400/200/1A(old used and

damaged)No 3

358 33 kv CT 200/5A completely burnt No 1

Page 56: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

359

132 KV CT400/200/1A(Completely

Damaged)No 1

360 3 Phase11KV PT 11000/110 V No 1

361

132 KV CT400/200/1A(Completely

Damaged &burnt)No 1

362 132 KV CT400/200/1A (burnt) No 1

363 33 KV CT800-400/1A No 1

364

36 KV CT 800/400/1A (old,used &

defective)No 1

365

36 KV CT with 4 core (3 for protection

and 1 for metering ) of rating

1600/800/1A with suitable CT

connectors with both side of CT from

reputed firm /original manufactureer

No 2

366

33 KV CT with 2 core of rating

200/100/1A No 0

367

33 KV Potential Transformer of

reputeted make 33/0.11 kv of class0.2

three core out door oil filled

No 0

368

Pressure relieve valve (PRV) assembly

outer part as per sample for 40 MVA

transformers

No 0

369 33 KV CT 400/200/1A (Damaged) No 1

370 (Old )48 V D/C DB Charger No. 1

371

110 Volt DC charger along with DB (old

& used)No 1

372 132 KV Wave Trappe No. 2

373 H T Compound Kg. 90

374 AL Scrap ( Clamp & Conductor) Kg. 35

375 Bottom & Top (Metallic) of old LA No. 18.00

376 Damage 33 KV CB No. 2.00

377 Meter box (old & used) No 1.00

378Steel wire Rope 3/4 Mtr. 200

379Steel Pilot Wire Mtr. 155

380 Disc Insulator No. 10

381 DE spanner set of 6 pcs No. 1

382 Speacial tool for 11 kv Biecco OCB No. 2

383 DE spanner O/S No. 10

384 Steel writing Table No. 1

385 Ring spanner No. 2

386 Torch 3 cell No. 1

387 Flate file No. 1

388 Hammer No. 2

389 Steel pully 4 sleeves No. 1

390 Notice Board No. 1

391 Aluminium ladder folding No. 1

392 Office Table No. 1

393 Steel Stool 600x300x32 No. 1

394 Camlong clamp No. 4

395 Manuale operated sag machine No. 1

396 Alluminium ladder 15' No. 1

397 Mobile phone Nokia 6030 No. 1

398

Mobile phone Samsung R220/ME

2352583/60/14397716No. 1

399 Mobile phone Nokia 603 No. 1

Page 57: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

400

HCL infinite Pro BL-1200 With combo

DVDNo. 1

401 15" TFT LCD flat6e type monitor No. 1

402 HCL 107 key Ps/2 key board No. 1

403 HCL USB optical mouse No. 1

404 256 MB RAM No. 1

405 56 kbps internal modem No. 1

406Koneca minolta 1350 page pro printer No. 1

407 1KVA uniline UPS No. 1

408 Godrej table T-08 No. 1

409Steel Almihre Size 1980x660x480 mm No. 1

410

Desert cooler metal body with exhaest

fanNo. 2

411

Multifunction printer samsung SCX4824

FN Sl No. 14B8BAXZ80037No. 1

412 Central table (Durain) No. 1

413 Samsung LCD TV 22" series 4 No. 1

414 Airtel disk connectio (2 set topbox) No. 1

415 Matress CHL No. 2

416 Visitor chair No. 2

417 Visitor chair No. 4

418 Split A.C. 1.5 Ton No. 1

419 Stabliser 4 KVA No. 1

420 First aid box No. 1

421

ADSL Modem(Broad Band Modem(with

IP-Sec))No. 1

422

Executive table with side unit of size 6x3

feetNo. 1

423

Table with both side drawer size 5x3

feetNo. 3

424

computer table with one side drawer on

steel frameNo. 3

425

Filling cabinet with four dwawer of size

52x15x27 inch of 20 gaugeNo. 4

426

Steel almihra with 5 shelves (20-22

gauge)No. 4

427 High back Executive chair No. 2

428 Low back Executive chair No. 5

429

Visitor chair with arm and cushion

(Revolving)No. 20

430 Steel bench with 3 seats No. 5

431

Aluminum ladder,folding double legs

with platform size 10 feetNo. 1

432

Round Table suitable for conference as

per room No. 1

433 Visitor Chair with arm No. 15

434 Notice board as per sample No. 1

435 Cup with plate and spoons Set 24

436 Water Glass standard No. 24

437 Induction Heater Branded No. 1

438

Tea Pan for induction with top cover

plateNo. 1

439 Bucket 20 Litre standard Quality No. 2

440 Mug standard Quality No. 2

441 Dustbin standard Quality No. 10

442 Dustbin with lid standard Quality No. 1

443Kitchen utensil Steel Stand wall mounted No. 1

Page 58: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

444 Room heater, Halogen with 4 rods No. 3

445 Desktop computer HP 406 G1 No. 1

446 Printwer HP Pro M202 DW No. 1

447 UPS APC 600 VA No. 1

448Steel wire Rope 3/4 Mtr. 200

449 Dismented 132 KV CT 400/200/1A Nos 4

450 Dismented 132 KV CT 800/400/1A Nos 2

451 132 KV CT400/200/1A (burnt) Nos 1

452 Dismented 132 KV IsolatorNo

s12

453Log book for 132 KV substation

RamnagarNos 0

454

Visitor chair with arm and cushion

(Revolving)No.

455 Multimeter No 2

456 Contact Resistance meter No 1

457 Double Bed No 1

458Safety Belt half body (Standard Quality) No 6

459 Earth Discharge rod No 2

460Steel bench having three seats

(standerd quality)No 5

461 Biomatric Attendance Machine No 1

462 132 KV Polycon Insulator No.

463 Old used and damaged MOG No.

464

Multistandard wire of different colour

2.5 SqmmISI Mark.Mtr 70

465 Phase identify plate set

466

Different type CT rod with

connector.Complete with

bushing,gasket,nut and washer etc.

set 17

467 Stay with insulation sleeves. Pcs

468 CFL lamp of rating 80 watt Nos 0

469

Flouresent tube light36 watt make

philipsNos 20

470

G.I Nuts& Bolts with washer of different

sizesNos 0

471

Supply of new iron sheet of pale fencing

of size 2.4x0.10M and SWG 18 including

nut and bolt.

Nos 0

472

supply of M.S 50x6mm angle for fixing of

pale fencing.RM 0

473 RTCC panel(Dismenteled) Nos 2

474

T Clamps suitable for Twin ACSR moose

to single ACSR Zebra Conductor.Nos

475

T Clamps suitable for Twin ACSR moose

to twin ACSR Zebra Conductor.Nos

476

33KV isolater clamp Suitable for Twin

ACSR moose Conductor.Nos

477

Gun fittings suitable for Twin ACSR

Moose Conductor.Nos

478

Separater Suitable for Twin ACSR Moose

Conductor.Nos

479

C-Wedge Clamp Suitable for ACSR

moose to moose Conductor.Nos

480 Fresh Transformer oil Drum Nos

Page 59: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

481MCB 230V AC Double Pole 16 Amp Nos 1

482

Supply of new 48 volt DC float cum

boost charger with dual charging Circuit

of rating 50 Ampere Suitable for 200Ah

battery Cells.

Nos 0

483

Lighting Spares Flexible PVC coated

copper wire 16 sq mm(red colour)Mtrs 0

484 wheel for revolwing chair set 4

485 silicagel breather container 01 Kg No 3

486 Chock 250 watt for HPSV lamp No 0

487 Pale fencing damged Kg 450

488 Battery Charger 48 volt (Dismentel) No 1

1 AA0A001001 ACSR ConductorTarantula Mtr.

2 AA0A004001 ACSR Conductor Zebra Mtr. 1486

3 AA0A005001 ACSR Conductor Panther Mtr. 873

4 AA0A008001 ACSR Conductor Dog Mtr.

5 AA0A011001 ACSR Conductor Rabbit Mtr.

6 AA0A012001 ACSR Conductor Weasel Mtr. 415

7 AA1A102001 GI Earth Wire 7/10 SWG Mtr. 645

8BB0B001002

Capacitor Bank-33 KV/36 KV 5 MVAR

Capacitor Bank Nos 1

9BB1B101001

Control Relay Panel for -2X5 MVAR

Capacitor BankNos 1

10BB2B201001

Single Phase Reactor-33KV Reactor for

cap. BankNos 4

11 BB4B401001 NCT- 5/1Amp Nos 2

12CC0C002008

PVC Control Cable - W/o Armoured-

10x2.5mmMtr

13CC0C002010

PVC Control Cable - W/o Armoured-

6x2.5mm Mtr

14CC0C002011

PVC Control Cable - W/o Armoured-

4x2.5mm Mtr

15CC0C002013

PVC Control Cable - W/o Armoured-

2x2.5mm Mtr

16CC1C102009

Power Cable -440V LT - - 3.5x95 Sq.

mmMtr

17CC1C102011

Power Cable -440V LT - - 3.5x50 Sq.

mmMtr

18CC2C201004

Control Cable- Armoured- - 3.5Cx35

Sq. mmMtr 0

19CC2C201006

Control Cable- Armoured- - 10Cx2.5

Sq. MMtr 617

20CC2C201007

Control Cable- Armoured- - 6Cx2.5 Sq.

MMtr 1205

21CC2C201009

Control Cable- Armoured- - 4Cx2.5 Sq.

MMtr 2304

22CC2C201011

Control Cable- Armoured- - 2Cx2.5 Sq.

MMtr 373

23 CC3C303003 XLPE cable - 33KV -- 300 Sq. mm Mtr 14

24 CC3C303005 XLPE cable - 33KV -- 70 Sq. mm Mtr 145

25 CC8C801008 -GI Cable Tray- Turfer gatted 6" Nos 3

26 CC8C801009 -GI Cable Tray- Turfer gatted 5" Nos 2

27 CC9C903001 -Plastic ferule a-z, 0-9- Nos 15

28 FF2F207040 Template C Type for 132KV Single Circuit M.T

29 FF3F301005 Strcture- ALP Kg 0.159

30 FF3F301008 Strcture- ATM Kg

132 KV Bazpur

Page 60: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

31 FF3F301009 Strcture- AXM Kg

32 FF3F301010 Strcture- BBL No 0.504

33 FF3F301013 Strcture-BCT No

34 FF3F301014 Strcture- BTM Kg

35 FF3F301019 Strcture- CCM Kg

36 FF3F301040 Strcture-Main lattice 33 KV Gantries Kg 295

37 FF3F301042 Strcture-33KV Isolator MT 0.358

38 FF3F302001 Tower Parts- GI MT

39FF4F401026

Galvanised Nuts & Bolts-16x38

mm/5/8" X 1*1/2Kg 2

40 FF4F401068 Galvanised Nuts & Bolts-Off Size Kg

41 FF7F701003 MS Earthing rod- 40 mm Dia MT

42 FF7F701004 MS Earthing rod- 36 mm dia Kg 0.443

43 FF7F702001 MS Flat- 75x10mm Kg 0.788

44 FF7F702003 MS Flat- 50x6mm Kg 0

45 FF7F702006 MS Flat- 25x6mm 0.614

46 FF8F801003 Pole-SP-45

47 FF8F801006 Pole-8.5 mtr. Round 4

48 FF9F904007 Copper - bond Flexible 34

49 FF1F103001 Double Circuit 132KV A Type MT 0.719

50 FF2F206001 Stub for 132KV D/c A Type MT 0.489

51 FF2F207029 Template A Type for 132KV Double Circuit M.T 2.251

52 FF2F207031 Template B Type for 132KV Double Circuit M.T 1.569

53 FF2F207033 Template C Type for 132KV Double Circuit M.T 2.286

54 FF3F302001 Tower Parts- GI MT 0.325

55GG0G001003

Maintenance material CRC 400 ML

BottelNo 0

56GG0G001013 Maintenance material Plastic compound 1

57HH0H005002

Line Isolator 33 KV Double break with

Earth switchNo

58 HH1H103001 Bus Isolator 132 KV No 1

59 HH1H105001 Bus Isolator 33 KV No 1

60

HH6H605002132 KV Isolater Spare Isolator Rotating

Assembly Pole contact assembly2

61 HH8H801001 33 KV Isolater Spare Jaws 4 6

62HH8H802005 33 KV Isolater Spare Blade Copper Tube 10

63 HH9H901012 Isolator Clamp singleZebra 8

64 HH9H901013 Isolator Clamp Twin Zebra 3

65 HH9H901016 Isolator Clamp singlePanter 9

66 II0I001001 Disc Insulator 160 KN Porceline No

67 II0I002001 Disc Insulator 120 KN Porceline No 0

68 II0I004001 Disc Insulator 70 KN No 76

69 II0I005001 Disc Insulator 22KN No 6

70 II1I104001 PG Clamp Zebra- Zebra No 23

71 II1I104002 PG Clamp Zebra- Panther No 51

72 II1I105001 PG Clamp Panther- Panther No. 50

73 II1I108001 PG Clamp Dog- Dog

74 II2I203002 C-wedge Clamp Deer- Zebra 8

75 II2I203003 C-wedge Clamp Deer- Panther 12

76 II2I204001 C-wedge Clamp Zebra- Zebra No 26

77 II2I204002 C-wedge Clamp Zebra- Panther 6

78 II2I205001 C-wedge Clamp Panther- Panther No 3

79

II3I306001 T-Connector Special Panther-

Panther

No 0

80 II5I501004 Mid Span Joint Panther No 26

81 II5I501009 Mid Span Joint 7/10 SWG No

Page 61: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

82 II5I502004 Repair Sleeve Panther No 8

83 II5I503003 Hanger ACSR Panther 3

84 II8I801005 Single Tension Fitting Panther No 1

85 II8I802005 Double Tension Fitting Panther Set 6

86 II8I804005 Single Suspension Fitting Panther No 6

87 II5I503004 Vibration Damper Panther No 156

88 II6I601004 Armour Rod Panther Set 3

89 II6I604001 Bird Guard No 90

90 II801010 Single Tension Fitting 7/10 SWG Nos 4

91

II8I805005 Double Suspension Fitting PantherNo

92 II8I807004 Single Gun Fitting Zebra No 3

93 II8I807005 Single Gun Fitting Panther No

94 JJ0J003001 Circuit Breaker 132KV SF-6 No 4 1

95 JJ0J003003 Circuit Breaker 132KV MOCB No

96JJ0J005002

Circuit Breaker 33KV 110V DC SF-

6No 4

97JJ0J005004

Circuit Breaker 33KV 110V DC

VCBNo 4

98 JJ0J005005 Circuit Breaker 33KV BOCB No 1 0

99 JJ0J005006 Circuit Breaker 33KV MOCB No 2 3

100JJ1J103005

Circuit Breaker Sapres 132KV 110V

DC Trip CoilNo

101JJ1J103007

Circuit Breaker Sapres 132KV 110V

DC 110V Closing CoilNo

102JJ1J105005

Circuit Breaker Sapres 33KV 110V

DC Trip CoilNo 16

103JJ1J105006

Circuit Breaker Sapres 33KV 110V

DC Trip Coil AssemblyNo

104JJ1J105007

Circuit Breaker Sapres 33KV 110V

DC Closing CoilNo 6

105JJ1J105008

Circuit Breaker Sapres 33KV 110V

DC Closing Coil AssemblyNo 1

106JJ1J105009

Circuit Breaker Sapres 33KV Moving

ContactNo 14

107JJ1J105012

Circuit Breaker Sapres 33KV Male

contactNo 6

108JJ1J105022 Circuit Breaker Sapres 33KV I-bolt No

109JJ1J105034

Circuit Breaker Sapres 33KV

Charging MotorsNo 1

110JJ2J201005

Circuit Breaker Auxiliary switch

LOCAL/Remote SwitchNo 7

111JJ2J202008

Circuit Breaker Auxiliary Contact (3

NO+ 2 NC)No

112 JJ3J301003 Relay Anti pumping Relay-8Pin No 1

113JJ4J401010

Circuit Breaker Connector Twin

PantherNo 6

114JJ6J601043

Circuit Breaker Accessories Bushing

insulatorNo 1

115JJ7J701043

OCB Sapres - 11KV - female main

Alimated finger contact No

116JJ7J701045

OCB Sapres - 11KV - male main

Alimated finger contact No

117 JJ8J801001 SF-6 Gas Kg 17

118 JJ8J802001 Empty Cylinder No 8

119KK0K003001 Lighting Arrestor 132 KV No 6

120KK0K004001 Lighting Arrestor 66 KV No

Page 62: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

121KK0K005001 Lighting Arrestor 33 KV No 3 1

122KK1K001007 Surge Counter 132 KV No

123KK4K401002

Post Insulator Poly cone Insulator -

132KV No 4 1

124KK4K401005 Post Insulator 33KV No 11

125LL0L003004 HPSV Lighting Material Lamp 250W No 2

126LL0L004004 HPSV Lighting Material Ignitor 250W No 1

127LL0L005004

HPSV Lighting Material Capacitor

250WNo 5

128LL0L008001

HPSV Lighting Material HPSV Lamp

fifting No 6

129LL0L009001

HPSV Lighting Material HPSV Lamp

Holder No 3

130

LL1L107001

Mercury Lighting Material Accessories

Covers and reflectors for various Sodium

Vapour/Mercury vapour lamps

No 4

131LL2L202004

Hallogen Lighting Material Copper

Ballast 250W/Choke 250 WNo 1

132LL3L301005

Flurocent Light Flurocent Light fitting

1x36 WNo

133 LL3L302001 Flurocent Light Choke 40W No 18

134 LL3L303001 Flurocent Light Flurocent Tube 40W No 28

135 LL4L401002 C.F.L. Complete fitting. 85W No 2

136 LL4L402006 C.F.L. C.F.L Lamp 25 watt No 22

137LL6L601002

Lighting Spares Flexible PVC coated

copper wire 16 sq mm(black colour)Mtr

138LL6L601003

Lighting Spares Flexible PVC coated

copper wire 04 sq mmMtr

139LL6L606001

Lighting Spares ACDB for Control

Room Light No

140 LL6L611002 Lighting Spares Sockets 5Amp No

141 LL7L701002 Exhaust Fan 1 phase No 2

142

MM0M00100

1

Relay - Distance Relay - Distance

protection relay Type YTG No

143

MM0M00400

1

Relay - Instant earth fault relay - Instant

earth fault relay Type-CAG No

144

MM0M00500

2

Relay - O/C & E/F Relay - O/C ,E/F

relay (Inverse Type) CDG.No

145

MM0M00600

1

Relay - Neutral Impedence Replica -

Neutral Imped Replica Type YTG-31. No

146

MM0M00700

1

Relay - Definite time relay - Definite

time relay Type Type - VTT. No

147

MM0M00900

1

Relay - Auxiliary relay - Auxiliary relay

Type VAA .No 2

148MM0M050001

Relay - Fuse Failure Relay - CVT Fuse

Failure RelayNo

149

MM1M111003

Miscellaneous Panel Spare - Semaphore -

Electronic semaphore indication-having

Red & Green LED 110 volt DC

No

150

MM1M118005

Miscellaneous Panel Spare - Trip

transfer switch - TNC Switch for control

panel-132kv/33kv

No 6

Page 63: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

151MM1M121008

Miscellaneous Panel Spare - Heater -

Strip Heater No 4 10

152MM2M202005

Analog Meter - Voltmeter - 0-40 KV,

PTR 33 KV/ 110 VNo 2

153MM2M203002

Analog Meter - Ampere Meter - 0-500

Amp, CTR 400/1 AmpNo 1

154MM2M203007

Analog Meter - Ampere Meter - CTR

200/100/5 ANo 3

155MM2M203010

Analog Meter - Ampere Meter - 0-125

Amp CTR 200/1 Amp.No 2

156MM2M203012

Analog Meter - Ampere Meter - 0-125

Amp CTR 100/1 AmpNo 2

157

MM2M204004

Analog Meter - MW Meter - M.W. meter

(0-25) 400/1A 33 KV/110 V A.E make

Analog

No 1

158MM2M204016

Analog Meter - KWH Meter - KWH

meter 3x100 A No 2

159

MM2M205014

Analog Meter - MVAR Meter - Analog

MVAR meter range CTR-400/1A (120-0-

120) MW

No 2

160MM2M206001

Analog Meter - Power factor meter -

400/1A with S/ switch No 3 3

161

MM3M301002

Digital Meter - Volt Meter - Volt Meter

A C -range 0-150 KV PTR 132KV/110

V. Aux Supply 110 V DC

No

162

MM3M301003

Digital Meter - Volt Meter - Volt Meter

(Rating 132000/110Volt) Auxiliary

Supply 110V DC

No 2

163MM3M301006

Digital Meter - Volt Meter - Volt Meter

132 KVNo 1

164

MM3M301011

Digital Meter - Volt Meter - Volt Meter

(Rating 33000/110Volt) Auxiliary

Supply 110V DC

No 3

165

MM3M302005

Digital Meter - Ampere Meter - Ampere

Meter for LT, 600/5 A, Aux supply 230

V AC

No

166

MM3M302006Digital Meter - Ampere Meter - Ampere

Meter size 150x150mm,CTR 400/1ANo 7

167

MM3M302013Digital Meter - Ampere Meter - Ampere

Meter size 150x150mm,CTR 200/1ANo 3

168

MM3M302023

Digital Meter - Ampere Meter - Ampere

Meter A C -range 0-500 A

(programmable) Aux Supply 110 V DC

No

169

MM3M303007

Digital Meter - MW Meter - MW Meter

Range - 150 to + 150 CTR-400/1A PTR-

132 KV/110V

No 1

170

MM3M303012

Digital Meter - MW Meter - MW Meter

Type 3 Phase 4 wire 50-0-50 MW CTR

200/1A PTR132KV /110 V. Aux Supply

110 V DC

No

171MM3M304011

Digital Meter - MVAR Meter - MVAR

Meter 33 KV-132/110 voltNo 1

172

MM3M307003Digital Meter - KWH (Energy meter) -

Energy meter secure make 1 Amp./110 V No 1

Page 64: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

173

MM3M307004

Digital Meter - KWH (Energy meter) -

data power energy meter 11 kv ( old

&used)defective

No 6

174

MM3M307005

Digital Meter - KWH (Energy meter) -

33 kv electronic energy metr secure

make

(old&used) defective

No 2

175NN2N206001 C&R PANEL - 11 KV - No

176NN3N303001 T/F C&R PANEL - 132/33 KV - No 1

177

NN9N906001

VCB PANELS -

INCOMING/BUSCOUPLER PANEL-

11 KV - V.C.B. incoming panel-11KV,

630 A, 350 MVA -make C.G.L.

No

178 PP0P001001 Steel Almera No

179 PP0P001002 Steel Rack No

180 PP0P003005 Computer Table No 1

181 PP0P004002 Oil Testing Set (defective) No 1

182 PP0P004003 2500 Volt Motor Insulation Testor No

183 PP0P004004 Centrifusing Machine No

184 PP0P006001 Single Sleeve Pulley Block No

185 PP0P006002 Double Sleeve Pulley Block No

186 PP0P006003 Tripple Sleeve Pulley Block No

187 PP0P006004 Industrial Helmet No 6

188

PP0P006005 Rubber Gloves No3 3

189

PP0P006006 Raincoat with cap No4 2

190

PP0P006007 Safety Belt No12

191

PP0P006008 Rubber Gum Boots No5 1

192

PP0P007001 Helmat No

193QQ1Q101003

Sub-Station Security Pale Fencing

Upright 2.4mtrNo 30

194QQ1Q104001 Sub-Station Security G I wire mesh No 78

195 SS4S404003 MCB 230V AC Single Pole 16 Amp No 5

196 SS4S404005 MCB 230V AC Single Pole 10 Amp No 5

197 SS4S405003 MCB 415 AC Tripple Pole 32 Amp. No 6

198 SS4S405006 MCB 415 AC Tripple Pole 6 Amp. No

199VV0V005002 Transformer 33/0.4 KV - 250 KVA No

200VV1V105010

Transformer Bushing -33/11 KV HV-

5 MVANo

201VV1V105011

Transformer Bushing -33/11 KV LV-

5 MVANo

202VV2V202001

Silica Gel Breather Assembly for

conservator No

203VV2V202002

Silica Gel Breather Assembly for

OLTCNo

204 VV2V203008 Silica Gel Blue crystal Kg 25

205VV2V204020

Terminal connector for bushing. LV-20

MVANo

206 VV3V301002 Oil Transformer Oil, Carbonised Ltr 4260

207 VV3V301007 Oil Empty Oil Drums No

Page 65: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

208 VV3V301008 Oil Empty Drum 45 Gallon No 43

209 VV3V303001 Oil Surge Relay For NGEF No

210VV4V401004

Transformer Spare Oil Temperature

indicator type 100 mm dia No 4

211

VV4V402001

Transformer Spare Winding Temperature

indicator Winding Temperature indicator

Meter

No

212VV4V403002

Transformer Spare Level Gauge

Magnetic oil Level GuageNo

213VV4V405008

Transformer Spare Exhaust fan Single

Phase 14 inchNo

214 VV5V502015 Filtering machine Spare Oil tray No 1

215VV6V603001

Current Transformer 145KV 800/400/1

A 5 core Accuracy 0.2No 2 3

216VV6V603003

Current Transformer 145KV

400/200/1A 5 core Accuracy 0.2No

217VV6V603004

Current Transformer 145KV

400/200/1A 3 core Accuracy 0.2No 3 2

218VV6V603005

Current Transformer 145KV

200/100/1A 5 core Accuracy 0.2No 3

219VV6V605001

Current Transformer 33 KV

1600/800/1A 5 Core Accuracy 0.2No 1

220VV6V605004

Current Transformer 33 KV 800/400/1

A 5 Core Accuracy 0.2No 3

221VV6V605005

Current Transformer 33 KV 800-

400/1A 3 core Accuracy 0.2No 1

222VV6V605006

Current Transformer 33 KV 800-

400/1A 3 core No 5

223VV6V605009

Current Transformer 33 KV

400/200/1A 3 core No 0 5

224VV6V605010

Current Transformer 33 KV

400/200/1A 2 core Accuracy 0.2No

225VV6V605012

Current Transformer 33 KV 300/150/1

ANo 3

226VV6V605013

Current Transformer 33 KV 200-

100/1Amp 3 Core No 3 12

227VV6V606004 Current Transformer 11 KV 600/5 A No

228VV6V606005 Current Transformer 11 KV 400/5 A No

229VV6V606006 Current Transformer 11 KV 300/5 A No

230VV6V606007

Current Transformer 11 KV 200/100/5

ANo

231VV7V701015

Current Transformer Terminal

Connectors Single Zebra ACSRNo 26

232VV7V701016

Current Transformer Terminal

Connectors Twin Zebra ACSRNo 3

233

VV7V701036

Current Transformer Terminal

Connectors 33 kv CT connector for

panther conductor (threaded type)

No 11

234VV7V705008

Current Transformer Junction Box

Terminal Link No 1

235VV8V805002

PT (Potential Transformer) PT 1-phase,

33KV/110 Volt -No 1 9

236VV8V810003

CVT CVT - CVT 132 KV/110 Volt -

145kv No 4 1

237YY0Y002005

Battery Set 110 Volt 300AH, acid

tubular battery setSet

238YY0Y003008

Battery Set 48 Volt 200AH, acid

tubeler battery setNo 1

Page 66: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

239YY1Y101005 Battery Cell 2 V 300AH lead acid No 2 140

240YY1Y101006

Battery Cell 2 V 200AH tublar lead

acid No

241YY2Y211001 Battery Spares Empty Acid Cans No 6

242YY6Y602023

Battery Charger Spares 110V DC

Control Card No 1

243YY6Y603027

Battery Charger Spares 48V DC

Thyristor/diode No 1

244 Series Reactor 6.6 KVA No.

245

33KV CT 400/200/1A(old used and

damaged)No 2

246 33 kv CT 200/5A completely burnt No

247

132 KV CT400/200/1A(Completely

Damaged)No

248 3 Phase11KV PT 11000/110 V No

249

132 KV CT400/200/1A(Completely

Damaged &burnt)No

250 132 KV CT400/200/1A (burnt) No

251 33 KV CT800-400/1A No

252

36 KV CT 800/400/1A (old,used &

defective)No 1

253

36 KV CT with 4 core (3 for protection

and 1 for metering ) of rating

1600/800/1A with suitable CT

connectors with both side of CT from

reputed firm /original manufactureer

No

254 KWH meter 3X200/1A No 5

255 KWH meter 3X200/1A No 4

256 KWH meter 3ø 400/1A No 1

257 Battery strip No 45

258 Plastic container (Distilled water) No 15

259 Worm wheel assembly No 4

260 High discharge rod No 1

261 Male moving contact damaged No 4

262 Rop garbay Nylon 25 mm No 10

263 Upper cap for MEI OCB No 1

264 Upper insulator with flange No 3

265 Upper fixed contact No 2

266 Lower fixed contact No 2

267 Motor relay 110 Volt No 1

268Cross jet pot for 33kv BHEL make BOCB No 1

269

Extinguishing chamber for 33 Kv BOCB

HEL MakeNo 5

270

Extinguishing chamber for 33 Kv MOCB

damaged No 1

271 C.T. 75/5A No 3

272

Damaged fix contact for MEI make

MOCBNo 6

273 Diverter switch assembly damaged No 1

274

Heat Shink cable termination kit for 33

Kv XLPE cable 3*120 mm² (Indoor) No. 4

275

Heat Shink cable termination kit for 33

Kv XLPE cable 3*120 mm² (Outdoor) No. 1

276 Nut & Bolts with washer MT. 0.90

Page 67: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

277

132KV CT rating 800/400/200/1A

old,used & damagedNo. 1

278MW Meter CTR 400/200/1A old & used. No. 1

279 Aluminum scrap (Clamp & jumper) Kg. 54

280 MS Angle 65X65X6 mm Kg. 35

281

Supply of GI Lattice structure for gantry

including Anchor bolts & GI nuts & boltsMT 0.143

282

LED light complete , 85 watt, 220V

AC , 50HZ with clamp and pipeNos 10

283Clamps suitable for fixing LED light Nos 10

284 M S Scrap (stub) MT 2

285Mid span joint for 7/3.5 G S earth wire No. 2

286Suspention clamp for 7/3.15 earth wire No. 1

287 Pilot Fitting for 70 KN Disc Insulator Nos. 9

288 Vaccum cleaner No. 1

289 Assessorice of Vaccum cleaner Set 1

290 Magger 2.5Kv u/s No. 1

291 Torch 3 cells u/s No. 1

292 Torch 2 cells u/s No. 1

293 Bomboo leaders long u/s No. 1

294 Bomboo leaders 20' long u/s No. 1

295 Alumminum leaders 20' long No. 1

296 Earth discharge rod No. 2

297 Centor Table No. 1

298 Double Bed No. 1

299 Matress No. 2

300

Table With both side drawer of size 5X3

feetNo. 1

301

Steel Almihra with 5 shelves (20-22

gauge)No. 2

302 Steel Bench with 3 seats No. 3

303 High back Executive chair No. 1

304 Low back Executive chair No. 2

305

Visitor chair with arm and cushion

(Revolving)No. 10

306 Biomatric Attendance Machine NO

307

33kv circuit breaker SF-6(old and

damaged)NO 1

308 33KV Jaws and blades for isolater set 4

309 Danger plate NO

310 Phase identify plate set

311

Different type CT rod with

connector.Complete with

bushing,gasket,nut and washer etc.

set

312

Tripping/Closing Coil,110Volt DC Suitable

for 33KV ABB Make Breakers as par

Sample.

NO 8

313

Tripping/Closing Coil,110Volt DC Suitable

for 33KV CGL Make Breakers as par

Sample.

NO 10

314

Tripping/Closing Coil,110Volt DC Suitable

for 132KV ABB Make Breakers as par

Sample.

NO 3

Page 68: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

315

Tripping/Closing Coil,110Volt DC Suitable

for 132KV CGL Make Breakers as par

Sample.

NO 8

316

Tripping/Closing Coil,110Volt DC Suitable

for 132KV Areva Make Breakers as par

Sample.

NO 5

317 Durid LCO Energiger NO 0

318 Durid Keypad NO 0

319

Standard galvanisied wire 1.2mm(A-

Grade)(Mtrs)Mtrs 53

32033KV CT 300/150/1A (Old& Dismenteld) No 3

1 AA0A001001 ACSR ConductorTarantula Mtr. 41

2 AA0A004001 ACSR Conductor Zebra Mtr. 46

3 AA0A005001 ACSR Conductor Panther Mtr. 419

4 AA0A008001 ACSR Conductor Dog Mtr. 52

5 AA0A011001 ACSR Conductor Rabbit Mtr.

6 AA0A012001 ACSR Conductor Weasel Mtr.

7 AA1A102001 GI Earth Wire 7/10 SWG Mtr.

8BB0B001002

Capacitor Bank-33 KV/36 KV 5 MVAR

Capacitor Bank Nos

9BB1B101001

Control Relay Panel for -2X5 MVAR

Capacitor BankNos

10BB2B201001

Single Phase Reactor-33KV Reactor for

cap. BankNos

11 BB4B401001 NCT- 5/1Amp Nos

12CC0C002008

PVC Control Cable - W/o Armoured-

10x2.5mmMtr 225

13CC0C002010

PVC Control Cable - W/o Armoured-

6x2.5mm Mtr 57

14CC0C002011

PVC Control Cable - W/o Armoured-

4x2.5mm Mtr 880

15CC0C002013

PVC Control Cable - W/o Armoured-

2x2.5mm Mtr 755

16CC1C102009

Power Cable -440V LT - - 3.5x95 Sq.

mmMtr 38

17CC1C102011

Power Cable -440V LT - - 3.5x50 Sq.

mmMtr 12 50

18DD0D004003

Multifunction printer model No. Scx

4521 F make SamsungNo.

19FF2F203024 Stub for 132KV S/c CCM type tower Kg 354.23

20 FF2F207036 Template A Type for 132KV Single Circuit No

21 FF2F207038 Template B Type for 132KV Single Circuit M.T

22 FF2F207040 Template C Type for 132KV Single Circuit M.T

23 FF3F301005 Strcture- ALP Kg

24 FF3F301008 Strcture- ATM Kg 2615.919

25 FF3F301009 Strcture- AXM Kg 1119.65

26 FF3F301010 Strcture- BBL No

27 FF3F301013 Strcture-BCT No

28 FF3F301014 Strcture- BTM Kg 2903.705

29 FF3F301019 Strcture- CCM Kg 354.23

30 FF3F301040 Strcture-Main lattice 33 KV Gantries Kg

31 FF3F301042 Strcture-33KV Isolator MT

32 FF3F302001 Tower Parts- GI MT 0

33FF4F401026

Galvanised Nuts & Bolts-16x38

mm/5/8" X 1*1/2Kg

132 KV Ramnagar

Page 69: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

34 FF4F401068 Galvanised Nuts & Bolts-Off Size Kg 0

35 FF7F701003 MS Earthing rod- 40 mm Dia MT

36 FF7F701004 MS Earthing rod- 36 mm dia Kg 1268

37 FF7F702001 MS Flat- 75x10mm Kg

38 FF7F702003 MS Flat- 50x6mm Kg 20

39 FF7F702006 MS Flat- 25x6mm

40 FF8F801003 Pole-SP-45 1

41 FF8F801006 Pole-8.5 mtr. Round

42 FF9F904007 Copper - bond Flexible 0

43 FF1F103001 Double Circuit 132KV A Type MT

44

HH6H605002132 KV Isolater Spare Isolator Rotating

Assembly Pole contact assembly

45 HH8H801001 33 KV Isolater Spare Jaws 6

46HH8H802005 33 KV Isolater Spare Blade Copper Tube 10

47 HH9H901012 Isolator Clamp singleZebra

48 HH9H901013 Isolator Clamp Twin Zebra

49 HH9H901016 Isolator Clamp singlePanter

50 II0I001001 Disc Insulator 160 KN Porceline No

51 II0I002001 Disc Insulator 120 KN Porceline No

52 II0I004001 Disc Insulator 70 KN No

53 II0I005001 Disc Insulator 22KN No

54 II1I104001 PG Clamp Zebra- Zebra No 4

55 II1I104002 PG Clamp Zebra- Panther No

56 II1I105001 PG Clamp Panther- Panther No. 70

57 II1I108001 PG Clamp Dog- Dog 11

58 II2I203002 C-wedge Clamp Deer- Zebra

59 II2I203003 C-wedge Clamp Deer- Panther

60 II2I204001 C-wedge Clamp Zebra- Zebra No

61 II2I204002 C-wedge Clamp Zebra- Panther

62 II2I205001 C-wedge Clamp Panther- Panther No 56

63

II3I306001 T-Connector Special Panther-

Panther

No

64 II5I501004 Mid Span Joint Panther No

65 II5I501009 Mid Span Joint 7/10 SWG No

66 II5I502004 Repair Sleeve Panther No 25

67 II5I503003 Hanger ACSR Panther 30

68 II8I801005 Single Tension Fitting Panther No 46

69 II8I802005 Double Tension Fitting Panther Set

70 II8I804005 Single Suspension Fitting Panther No

71 II5I503004 Vibration Damper Panther No 82

72 II6I601004 Armour Rod Panther Set

73 JJ0J005006 Circuit Breaker 33KV MOCB No

74JJ1J103005

Circuit Breaker Sapres 132KV 110V

DC Trip CoilNo 3

75JJ1J103007

Circuit Breaker Sapres 132KV 110V

DC 110V Closing CoilNo 1

76JJ1J105005

Circuit Breaker Sapres 33KV 110V

DC Trip CoilNo

77JJ1J105006

Circuit Breaker Sapres 33KV 110V

DC Trip Coil AssemblyNo 5

78JJ1J105007

Circuit Breaker Sapres 33KV 110V

DC Closing CoilNo

79JJ1J105008

Circuit Breaker Sapres 33KV 110V

DC Closing Coil AssemblyNo

80JJ1J105009

Circuit Breaker Sapres 33KV Moving

ContactNo

Page 70: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

81JJ1J105012

Circuit Breaker Sapres 33KV Male

contactNo

82JJ1J105022 Circuit Breaker Sapres 33KV I-bolt No 7

83JJ1J105034

Circuit Breaker Sapres 33KV

Charging MotorsNo

84JJ2J201005

Circuit Breaker Auxiliary switch

LOCAL/Remote SwitchNo

85JJ2J202008

Circuit Breaker Auxiliary Contact (3

NO+ 2 NC)No

86 JJ3J301003 Relay Anti pumping Relay-8Pin No

87JJ4J401010

Circuit Breaker Connector Twin

PantherNo

88JJ6J601043

Circuit Breaker Accessories Bushing

insulatorNo

89JJ7J701043

OCB Sapres - 11KV - female main

Alimated finger contact No

90JJ7J701045

OCB Sapres - 11KV - male main

Alimated finger contact No

91 JJ8J801001 SF-6 Gas Kg 20

92 JJ8J802001 Empty Cylinder No

93KK0K003001 Lighting Arrestor 132 KV No 0

94KK0K004001 Lighting Arrestor 66 KV No

95KK0K005001 Lighting Arrestor 33 KV No 3

96KK1K001007 Surge Counter 132 KV No 3

97KK4K401002

Post Insulator Poly cone Insulator -

132KV No

98KK4K401005 Post Insulator 33KV No

99LL0L003004 HPSV Lighting Material Lamp 250W No

100LL0L004004 HPSV Lighting Material Ignitor 250W No

101LL0L005004

HPSV Lighting Material Capacitor

250WNo

102LL0L008001

HPSV Lighting Material HPSV Lamp

fifting No

103LL0L009001

HPSV Lighting Material HPSV Lamp

Holder No

104

LL1L107001

Mercury Lighting Material Accessories

Covers and reflectors for various Sodium

Vapour/Mercury vapour lamps

No

105LL2L202004

Hallogen Lighting Material Copper

Ballast 250W/Choke 250 WNo 7

106LL3L301005

Flurocent Light Flurocent Light fitting

1x36 WNo

107 LL3L302001 Flurocent Light Choke 40W No

108 LL3L303001 Flurocent Light Flurocent Tube 40W No 4

109 LL4L401002 C.F.L. Complete fitting. 85W No

110 LL4L402006 C.F.L. C.F.L Lamp 25 watt No

111LL6L601002

Lighting Spares Flexible PVC coated

copper wire 16 sq mm(black colour)Mtr

112LL6L601003

Lighting Spares Flexible PVC coated

copper wire 04 sq mmMtr

Page 71: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

113LL6L606001

Lighting Spares ACDB for Control

Room Light No

114 LL6L611002 Lighting Spares Sockets 5Amp No

115 LL7L701002 Exhaust Fan 1 phase No 4

116

MM0M00100

1

Relay - Distance Relay - Distance

protection relay Type YTG No

117NN2N206001 C&R PANEL - 11 KV - No

118NN3N303001 T/F C&R PANEL - 132/33 KV - No

119

NN9N906001

VCB PANELS -

INCOMING/BUSCOUPLER PANEL-

11 KV - V.C.B. incoming panel-11KV,

630 A, 350 MVA -make C.G.L.

No

120 PP0P001001 Steel Almera No 4

121 PP0P001002 Steel Rack No 2

122 PP0P003005 Computer Table No 1

123 PP0P004002 Oil Testing Set (defective) No

124 PP0P004003 2500 Volt Motor Insulation Testor No 1

125 PP0P004004 Centrifusing Machine No

126 PP0P006001 Single Sleeve Pulley Block No 1

127 PP0P006002 Double Sleeve Pulley Block No 1

128 PP0P006003 Tripple Sleeve Pulley Block No 1

129 PP0P006004 Industrial Helmet No

130

PP0P006005 Rubber Gloves No

131

PP0P006006 Raincoat with cap No

132

PP0P006007 Safety Belt No

133

PP0P006008 Rubber Gum Boots No

6

134

PP0P007001 Helmat No

6

135QQ1Q101003

Sub-Station Security Pale Fencing

Upright 2.4mtrNo

136QQ1Q104001 Sub-Station Security G I wire mesh No

137 SS4S404003 MCB 230V AC Single Pole 16 Amp No 0

138 SS4S404005 MCB 230V AC Single Pole 10 Amp No

139 SS4S405003 MCB 415 AC Tripple Pole 32 Amp. No

140 SS4S405006 MCB 415 AC Tripple Pole 6 Amp. No

141VV0V005002 Transformer 33/0.4 KV - 250 KVA No

142VV1V105010

Transformer Bushing -33/11 KV HV-

5 MVANo

143VV1V105011

Transformer Bushing -33/11 KV LV-

5 MVANo

144VV2V202001

Silica Gel Breather Assembly for

conservator No 2

145VV2V202002

Silica Gel Breather Assembly for

OLTCNo 1

146 VV2V203008 Silica Gel Blue crystal Kg 10

147VV2V204020

Terminal connector for bushing. LV-20

MVANo 3

148 VV3V301002 Oil Transformer Oil, Carbonised Ltr

149 VV3V301007 Oil Empty Oil Drums No 30

150 VV3V301008 Oil Empty Drum 45 Gallon No

Page 72: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

151 VV3V303001 Oil Surge Relay For NGEF No 1

152VV4V401004

Transformer Spare Oil Temperature

indicator type 100 mm dia No

153

VV4V402001

Transformer Spare Winding Temperature

indicator Winding Temperature indicator

Meter

No

154VV4V403002

Transformer Spare Level Gauge

Magnetic oil Level GuageNo

155VV4V405008

Transformer Spare Exhaust fan Single

Phase 14 inchNo 2

156 VV5V502015 Filtering machine Spare Oil tray No

157VV6V603001

Current Transformer 145KV 800/400/1

A 5 core Accuracy 0.2No 1

158VV6V603003

Current Transformer 145KV

400/200/1A 5 core Accuracy 0.2No

159VV6V603004

Current Transformer 145KV

400/200/1A 3 core Accuracy 0.2No

160VV6V603005

Current Transformer 145KV

200/100/1A 5 core Accuracy 0.2No

161VV6V605001

Current Transformer 33 KV

1600/800/1A 5 Core Accuracy 0.2No

162VV6V605004

Current Transformer 33 KV 800/400/1

A 5 Core Accuracy 0.2No

163VV6V605005

Current Transformer 33 KV 800-

400/1A 3 core Accuracy 0.2No 0

164VV6V605006

Current Transformer 33 KV 800-

400/1A 3 core No

165VV6V605009

Current Transformer 33 KV

400/200/1A 3 core No 1

166VV6V605010

Current Transformer 33 KV

400/200/1A 2 core Accuracy 0.2No 4

167VV6V605012

Current Transformer 33 KV 300/150/1

ANo

168VV6V605013

Current Transformer 33 KV 200-

100/1Amp 3 Core No 2 1

169VV6V606004 Current Transformer 11 KV 600/5 A No

170VV6V606005 Current Transformer 11 KV 400/5 A No

171VV6V606006 Current Transformer 11 KV 300/5 A No

172VV6V606007

Current Transformer 11 KV 200/100/5

ANo

173VV7V701015

Current Transformer Terminal

Connectors Single Zebra ACSRNo

174VV7V701016

Current Transformer Terminal

Connectors Twin Zebra ACSRNo

175

VV7V701036

Current Transformer Terminal

Connectors 33 kv CT connector for

panther conductor (threaded type)

No

176VV7V705008

Current Transformer Junction Box

Terminal Link No

177VV8V805002

PT (Potential Transformer) PT 1-phase,

33KV/110 Volt -No 2

178VV8V810003

CVT CVT - CVT 132 KV/110 Volt -

145kv No 4

179YY0Y002005

Battery Set 110 Volt 300AH, acid

tubular battery setSet 1

180YY0Y003008

Battery Set 48 Volt 200AH, acid

tubeler battery setNo

Page 73: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

181YY1Y101005 Battery Cell 2 V 300AH lead acid No 5

182YY1Y101006

Battery Cell 2 V 200AH tublar lead

acid No

183

Pressure relieve valve (PRV) assembly

outer part as per sample for 40 MVA

transformers

No

184 33 KV CT 400/200/1A (Damaged) No 1

185 (Old )48 V D/C DB Charger No.

186 Biomatric Attendance Machine No

187 132 KV Polycon Insulator No. 4

188 33 KV Pin insulator No. 11

189 33 KV Pin with nut No. 9

190 Defective Auxillary C.T. Set 1

191

Terminal Connector required for 33 KV

isolator Suitable for ACSR Panther

Conductor

No. 3

192

Old used & damaged Bucholz Relay for

20 MVA T/FKg 8

193

Old used & damaged Gate Valve for 20

MVA T/FKg 8

194

Old used & damaged Magnetic Oil

Gauge for 20 MVA T/FKg 0.5

195

Old used & damaged Silica gel Breather

for 20 MVA T/FKg 1

196 Old used and damaged MOG No. 1

197

Multistandard wire of different colour

2.5 SqmmISI Mark.Mtr 0

198GI foundation Anchor bolt (size 28 mm) No 20

199GI foundation Anchor bolt (size32 mm) No 10

200

LED light complete ,85 Watt ,220 AC 50

Hz with clamp and pipeNo 10

201 Clamp suitable for fixing LED Light No 10

202 Torch No 1

203 Earth Resistivity Tester No 1

204Hydraulic Crimping Tool 400-1000sqm No 1

205 5000V Motorized Insulation Tester No 1

206 3 1/2 Digit Digital Multimeter No 1

207 Portable Air Blower No 2

208 Steel Table 5"x3"x2 1/2" No 2

209 Armed Steel Chair 'S' Type No 6

210 Steel Stool 1'x1 1/2'x1 1/2' No 1 1

211 Wooden Telephonen Desk No 1

212 Wooden Dining Set No 1

213 Wooden Easy Chair (Cushion) No 4

214 Canter table No 1

215 Single Bed Wooden No 2

216 D/E Spanner Set 6-7 to 30-32 No 1

217 Ring Spanner Set 6-7 to 30-32 No 1

218 Screw Driver SET No 1

219 Combination Pliers No 1

220 Cutting Pliers No 1

221 Nose Pliers No 1

222 Hack Saw Frame No 1

223 Allen Key Set No 2

224 Screw Driver Large NO 1

Page 74: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

225 Screw Driver Medium NO 1

226 Socket Spanner Set(JHALANI) NO 1

227 Soldring Iron NO 1

228

Nokia Hand Set

Model3100352974005000120NO 1

229 Slide Wrench 300mm NO 1

230 D/E Spanner Set 6mm to 32mm NO 2

231 Detachable Screw Driver NO 1

232 300mm Screw Driver NO 1

233 Box Spanner Set NO 1

234

Crimping Tool for Pressing Lugs for of

cable 2.5 mm to 35mm hand operatedNO 1

235

Hydraulic Crimping Tool for pressing

Lugs of Cable size 35 mm to 300mmNO 1

236

Aluminum Ladder Wall Suporting Folding

type in Two Pieces Total Working length

24 Ft with Pully &sisal Rope

NO 1

237

Aluminum Ladder Wall Suporting Having

Total Working Length of 18 Ft Long in

two parts with sliding arrangment safe

length up to 24 Ft with suitable Pully &

sisal Rope

NO 1

238Oil Testing Set (0 to 100 KV)Motorized NO 1

239 Desk Top Computer HCL Make 1

240 TFT 39.5 Monitor HCL Make NO 1

241 UPS 1.0 KVA,168 VAH Uniline Make NO 1

242 Biligual Key Board NO 1

243 Combo Drive NO 1

244 McAfee Anti Virus NO 1

245 Internal Modem(56kbps) NO 1

246

Multi function Printer samsung SCX-

4521F S.No. -8P67BACZ801698NO 1

247 Pipe Wrench 18' NO 1

248 Combination Plier NO 1

249 Nose Plier NO 1

250 Earth Chain NO 1

251 Hammer 500gm NO 1

252 First Aid Box NO 1

253 Screw Driver Set NO 1

254 Pick Axe 500gm NO 1

255 Scissor NO 1

256 Digital Multimeter NO 1

257 Sefety Belt half Body NO 6

258 Sefety Belt full Body NO 6

259 Hand Gloves NO 6

260 Earth discharge rod NO 2

261

First Aid Box Complete With All

MedicinesNO 1

262 Rain coats NO 6

263 Double Bed NO 1

264 Matters (CHL) NO 2

265 Table with both side door NO 1

266 Steel bench with three seat NO 2

267 High back executive chair NO 1

268 Low Back executive chair NO 2

Page 75: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

269 Visitor Chair NO 10

270 Biomatric Attendance Machine NO 1

271

33kv circuit breaker SF-6(old and

damaged)NO

1 AA0A001001 ACSR ConductorTarantula Mtr. 64

2 AA0A005001 ACSR Conductor Panther Mtr. 31

3 AA1A101001 GI Earth Wire 7/9 SWG Kg 194

4CC0C002011

PVC Control Cable - W/o Armoured-

4x2.5mm Mtr 160

5CC0C002013

PVC Control Cable - W/o Armoured-

2x2.5mm ( in pices)Mtr 632

6CC1C102002

Power Cable -440V LT - - 3.5x400 Sq.

mmMtr 275

7CC1C102011 Power Cable -440V LT - - 3.5x50 Sq. mm Mtr 195

8 FF0F002001 Single Circuit 220KV - A Type kg 7151

9 FF0F002007 Single Circuit 220KV - B Type kg 16150

10FF0F003018 Single Circuit 132KV ALP type tower Kg 1272.28

11FF0F003019 Single Circuit 132KV CCR type tower Kg 4207

12FF0F003020 Single Circuit 132KV CGR type tower Kg 828.27

13FF0F003021 Single Circuit 132KV CRP type tower Kg 554.26

14FF0F003022 Single Circuit 132KV BXM type tower Kg 2542.22

15FF0F003023 Single Circuit 132KV ETM type tower Kg 1831.6

16FF0F003024 Single Circuit 132KV CCM type tower Kg 3205

17FF0F003025 Single Circuit 132KV CBT type tower Kg 2163.23

18FF0F003026 Single Circuit 132KV ATMS type tower Kg 2555.17

19FF0F003027 Single Circuit 132KV CGM type tower Kg 2268.47

20FF2F207022

Template A Type for 220KV Single

Circuit kg 294.88

21FF2F207024

Template B Type for 220KV Single

Circuit kg 710.88

22FF2F207026

Template C Type for 220KV Single

Circuit kg 973.48

23 FF4F402019 HOT dipped Galvanised-16x60 mm No 135

24FF4F402023

HOT dipped Galvanised-16x50 mm / 16

X 2"/5/8" No 385

25 FF4F402024 HOT dipped Galvanised-16x40 mm No 1521

26FF4F402025

HOT dipped Galvanised-16x45 mm/

(5/8"x1*3/4No 1000

27 FF7F702001 MS Flat- 75x10mm Kg 116

28 FF7F702003 MS Flat- 50x6mm MT 0.2

29 FF8F802001 Rail- 105 LBS 1.80 mtr. Long Kg 1077.38

30HH0H005001 Line Isolator 33 KV with Earth switch No 5

31 HH1H103001 Bus Isolator 132 KV No 3

32 HH9H901016 Isolator Clamp singlePanter No 6

33 II0I002001 Disc Insulator 120 KN Porceline No 202

220KV S/S Haldwani

Page 76: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

34 II6I602003 Jumpher Cone Zebra No. 3

35 II8I801004 Single Tension Fitting Zebra No 41

36 II8I801005 Single Tension Fitting Panther No 2

37 II8I804004 Single Suspension Fitting Zebra No 26

38 II8I804009 Single Suspension Fitting 7/9 SWG No 6

39 JJ8J802001 Empty Cylinder No 2

40 KK0K002001 Lighting Arrestor 220 KV No 4

41 KK4K401001 Post Insulator Solid core - 245 KV No. 4

42 KK4K401003 Post Insulator Solid core - 145 KV No 38

43MM4M425001

Miscellaneous- - Relay contact multiplier

- Relay contact multiplierNo 62

44MM4M426001 Miscellaneous- - Relay socket - for 51 No 65

45 PP0P008001 Die set for ACSR Moose Allu. No 1

46 PP0P008002 Die set for ACSR Moose steel No 1

47 PP0P008005 Die set earth wire 7/10SWG No 1

48 SS3S301010 Fuse HRC - 32 amp no 29

49 SS3S301022 Fuse HRC - 6A no 29

50 SS3S301024 Fuse HRC - 4A No 23

51 SS3S301026 Fuse HRC - 2A No 23

52VV1V102004

Transformer Bushing -220/132 KV HV-

100 MVANo 1

53VV1V102005

Transformer Bushing -220/132 KV LV-

100 MVANo 1

54VV1V104004

Transformer Bushing -132/33KV HV-

40 MVANo 1

55VV5V504001 Transformer Balancing Coupling unit No 1

56 Bushing asssembly 220 kv No 1

57 Fencing part 3 mtr long fabricated kg 37

58 Empty SF6 gas cylinder No 2

59 Intermediate upright with cleat No 11

60 Stay with cleat No 34

61 MSC Joint for zebra No 17

62 Alluminium portion for MSC Joint No 4

63 PA rod for zebra No 7

64 CUM along clamp No 1

65 Isolator connector for trumtulla No 6

66 TER Bushing CT 3 core No 1

67 NEUTRAL BUSHING CT 1 CORE No 1

68 Terminal contactor for 145 KV CT no 1

69 245 kv sc PI No 4

70

145 KV solid core part insulator W/OL

clampNo 38

71 GI step bolt No 1976

72 Mol Gauge No 1

73 Explo -vent diaphram No 1

74 33.33MVA 220/132 KV T/F Main tank No 2

75 accessoires Part Above No 2

76 Fancy part 3 m long Fabricated Kg 37

1 AA0A005001ACSR Conductor Panther Mtr. 7315

2 AA0A004001ACSR Conductor Zebra Mtr. 180

3 AA0A012001ACSR Conductor Weasel Mtr. 1210

4 AA1A102001GI Earth Wire 7/10 SWG Kg. 9312

5 AA1A103001GI Earth Wire 7/16 SWG Kg. 17.5

6 AA3A301001Stay wire 7/8 SWG Kg. 370

C

o

d

e

N

o

t

P

r

o

v

i

d

e

d

132KV S/S Kathgodam

Page 77: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

7

BB1B101002

Control Relay Panel for -Control

Relay Panel complete for 5 MVAR

Capacitor Bank

No 1

8

CC0C00200

8

PVC Control Cable - W/o Armoured-

10x2.5mmMtr 150

9

CC0C00201

1

PVC Control Cable - W/o Armoured-

4x2.5mm Mtr 150

10

CC1C10200

2

Power Cable -440V LT - - 3.5x400

Sq. mmMtr 116

11 CC3C303003 XLPE cable - 33KV -- 300 Sq. mm Mtr 200

12 CC7C703002 - Lugs-AL.240 sq. mm No 22

13CC9C901003

-Cable Box - 11 KV 3x400mm2

straight throughNo 2

14 FF8F803002 Rod -Stay 17.5 mm² with nut No. 206

15 FF9F903001 Arm- 33KV X type No 5

16 FF9F904003 Copper -Bond Round No 11

17 HH1H103001Bus Isolator 132 KV No 15

18HH6H601002

132 KV Isolater Spare Jaws Long

Strip TypeNo 6

19HH6H602003

132 KV Isolater Spare Blade Male

arm assemblyNo 1

20 HH7H70100166 KV Isolater Spare Jaws No 7

21HH8H801007

33 KV Isolater Spare Jaws 2 Finger

contactNo 6

22HH8H802003

33 KV Isolater Spare Blade 800

Amp. No 2

23 II0I002001 Disc Insulator 120 KN Porceline No 39

24II0I006001

Disc Insulator 11 KV (11500 kg

X pin52

25 II1I104001 PG Clamp Zebra- Zebra No 11

26 II1I104002 PG Clamp Zebra- Panther No 19

27 II1I105001 PG Clamp Panther- Panther No 6

28 II1I108001 PG Clamp Dog- Dog No 352

29 II2I205001 C-wedge Clamp Panther- Panther No 47

30II4I401001

Stay Clamp/Earth Wire Clamp other

Clamps Stay Clamp For poleNo 386

31 II4I401002 Stay Clamp For Rail No 49

32II4I403003

Earth Wire Suspension Clamp 7/16

SWG13

33 II4I408001 PP Clamp For SP pole No 184

34 II4I409001 Bracing clamp of ms flat 65x8mm No 401

35 II5I501004 Mid Span Joint Panther No 16

36 II5I501009 Mid Span Joint 7/10 SWG No 10

37 II5I502004 Repair Sleeve Panther No 24

38 II5I502009 Repair Sleeve 7/10 SWG No 10

39 II6I601004 Armour Rod Panther Set 15

40 II6I603001 Plate Number Plate No 110

41II6I603003

Plate Phase Plate In colour wise R

Y BSet 1

42 II6I603005 Plate Circuit Plate Set 1

43 II6I603006 Plate Danger Plate No 1

44II7I710001

Anti clamping device Anti clamping

device for 132kv lineset 1

45 II8I801005 Single Tension Fitting Panther No 1

46 II801010 Single Tension Fitting 7/10 SWG No 10

47 II8I804005 Single Suspension Fitting Panther No 19

48II8I804006

Single Suspension Fitting Special

Pantherset 38

Page 78: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

49II8I804010

Single Suspension Fitting 7/10

SWGNo 10

50 II8I807004 Single Gun Fitting Zebra No 4

51 JJ0J004001 Circuit Breaker 66KV SF-6 No 3

52JJ1J103005

Circuit Breaker Sapres 132KV

110V DC Trip CoilNo 4

53JJ1J103007

Circuit Breaker Sapres 132KV

110V DC 110V Closing CoilNo 3

54JJ1J103041

Circuit Breaker Sapres - 132KV -

CatchesNo 1

55JJ2J202010

Circuit Breaker Auxiliary Contact

2 NO+2 NCNo. 5

56 JJ5J502001 O Ring SEAL PACKING (O) No 5

57

KK0K00300

1Lighting Arrestor 132 KV No 3

58

KK0K00400

1Lighting Arrestor 66 KV No

59

KK0K00500

1Lighting Arrestor 33 KV No 6

60

KK4K30100

2

Base Insulator Base For Unit of 360

KV Station Class Liner Type Surge

Arrestor 120/132 KV

No.

61

KK4K30100

4Base Insulator 66kv No. 5

62

KK4K40100

2

Post Insulator Poly cone Insulator -

132KV no. 1

63

KK4K40100

4 Post Insulator Porcelain -36KV No. 2

64

KK4K40200

1 Pin Insulator - 33 KV No. 69

65LL6L610005

Lighting Spares Threaded holder for

250/400 Watt HPSV Lamp. No. 11

66MM2M202016

Analog Meter - Voltmeter - 0-500V

415VACNo 1

67

NN7N70700

1

OLTC PANEL - - OLTC

PanelDamaged old & usedNo 1

68 SS3S301020 Fuse HRC - 10A No. 30

69 SS3S301022 Fuse HRC - 6A No. 36

70 SS3S301024 Fuse HRC - 4A No. 19

71 SS3S311001 Fuse Trip indicator fuse (TI300) No 20

72 SS4S405002 MCB 415 AC Four Pole 32 Amp. No. 2

73SS4S405005 MCB 415 AC Tripple Pole 10 Amp. No. 10

74VV1V104005

Transformer Bushing -132/33KV

LV-40 MVAno 2

75 VV2V202008 Silica Gel Breather Capacity 5 kg. No 1

76 VV3V301007 Oil Empty Oil Drums No 235

77VV6V603007

Current Transformer 145KV 100/1A

3 core Accuracy 0.23

78VV6V605006

Current Transformer 33 KV 800-

400/1A 3 core No 4

79VV6V605012

Current Transformer 33 KV

300/150/1 ANo. 3

80VV6V606007

Current Transformer 11 KV

200/100/5 ANo 22

81VV7V702003

Current Transformer Connecting

Rod 132 KV No 3

Page 79: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

82VV7V702004

Current Transformer Connecting

Rod 33 KV No 6

83VV8V809002

PT (Potential Transformer) PT 1-

phase, 11 KV/110 Volt -No 2

84 VV8V812001 Coupling Capacitor Cell No. 5

85

YY1Y10100

6

Battery Cell 2 V 200AH tublar lead

acid No 20

86 33kv disc fitting for dog No 31

87 G.I bolt nuts of sizes No 4483

88 breacing clamp of sizes No. 401

89 stay rod complete set 206

90 33kv F clamp No 328

91 P.P Clamp for 105lb No 40

92 breacing clamp of rail No 32

93 bolted type tension fitting for zebra No 4

94 33kv disc fitting fot dof pin w/o nut No 80

95 rollery insulator No 3

96 alu strip 3*2.5mm mtr 10

97 33KV support insulator No 0

98

M.S nuts and bolts suitable for fencing

workKg 80

99

G.I wire mess of 10SWG aperture 50mm

width 1.8mmSqm 459

100 MS Flat 50*6mm Kg 1874.076

101 33 K.V Bushing Insulator No. 2

102 132 K.V Breacing Insulator No. 1

103 MS Angle 50*50 Kg 2639

104 Relay Of Sizes No. 7

10572.5 K.V 400 Amp Condensor Bushing No. 2

106 single phase voltmeter No 1

107 surge capacitor 2uf/440 v ac No. 4

108 Steel Wire Rope Mtr 200

109 Vehicle Scrap Kg 1

110 Space heater 2500HM/250W No. 2

111 capacitor 2200UFD/350V DC No 2

112 capacitor 3000UFD/350V DC No. 2

113 Comes Cord Assembly No. 1

114 Fish Plates 105 lbs No. 16

115

Contactor 25A 3 phase coil voltage 240v

dcNo 1

116

Contactor 63A 3 phase coil voltage 240v

dcNo 1

117 Anchor Bolt 25mm No. 49

118 132/33 K.V C.T Connector No. 75

119 fuse 36AGE SM63A No. 6

120Cable Termination Box 450*450*200mm No. 8

121 33 K.V Insulator Ciment Type No. 1

122 Magnet 110 V-127V D.C(A.B.B) No. 4

123 Linkage(A.B.B) No. 1

124 copper bonds No. 11

125 Pressure Release Valve No. 1

126 Brass Nut Bolt of Sizes No. 124

127 AC Single phase 415V 8A MCB No. 4

128 Heaters No. 3

129 catch(ABB) No. 1

130 selector switches for 132 kv panels No. 8

131 Indicators No. 14

C

o

d

e

N

o

t

P

r

o

v

i

d

e

d

Page 80: Name of Subsation: 132KV Substation Almora Dismantle/Inco ... · 36KV,1250Amp.25KA, VCB BHEL Make No. 1 104 C-Wedge Clamp Suitable for ACSR P/P Conductor No. 22 105 C-Wedge Clamp

132 Come Along Ckamp for Zebra No. 2

133 LED Type Semaphore No. 5

134 66 kv CT connecter No. 12

135 CT CLAMPS NO 12

136 G.I STRUCTURE MT 0.087

137 M.s Earth 400 mm Dia Mtr 19

138 Diodes S4hr41 M8 No 3

139 semi conductor fuse 75AGSA75 No 6

140 semi conductor fuse 50AGSA50 No 6

141 1/2 unfscr of 110v battery charger No 6

142 ABB PB unit No 2

143 Counter poise earthing set 1

144 selectoe switch(manual/auto) No 4

145 132kv isolator connector No 5

146 33kv support insulator No 0

147 33kv v type x-arm No 5

148 AL lug 400mm No 6

149 Anchor bolt 28mm No 91

150 Anchor bolt 32mm No 14

151 Insulating Mat Mtr 60

152 Diodes S8hr55M8 No 3

153 Diodes S8hr416M8 No 3

154 CONTACTOR MNX-32 NO 1

155

Spring Charging motor 110 V DC for 33

KVNo 0

156

33 Kv Spring Charging motor Old & Burnt

DifectiveNo 2

C

o

d

e

N

o

t

P

r

o

v

i

d

e

d