nano quantity analyte detector (nqad) a new aerosol-based hplc detector february 2008
TRANSCRIPT
![Page 1: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/1.jpg)
Nano Quantity Analyte Detector (NQAD)
A New Aerosol-based HPLC Detector
February 2008
![Page 2: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/2.jpg)
Quant Technologies LLC
Quant Technologies was founded in 2003 as a subsidiary of Power Engineering & Manufacturing, Inc. (PEM)
Our primary focus is engineering design & instrumentdevelopment, and manufacturing
Our Mission: To bring to market high quality, innovative and affordable aerosol instrumentation for applications in basic and applied research, environmental studies, process and quality control, and occupational health and safety.
![Page 3: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/3.jpg)
A History of Success
In 2003, Quant licensed a remarkable new technology from Aerosol Dynamics, Inc. for laminar-flow water-based condensation particle counting. Our first commercial product was developed within one year of licensing.
Product line includes:
A family of four Water Condensation Particle Counters (WCPCs) for basic and applied aerosol research ,and are marketed exclusively by TSI Incorporated
A Nonvolatile Residue Monitor for measuring impurity levels in ultrapure water systems for the semiconductor industry; marketed exclusively by Fluid Measurement Technologies, Inc.
The new Nano Quantity Analyte Detector (NQAD)
![Page 4: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/4.jpg)
Design & Development
• Successful partnering with inventors and technology leaders
• Skilled senior-level engineering design team with almost 30 years experience developing state-of-the-art scientific aerosol instrumentation
• In-house expertise in electronics, optics, mechanical design, firmware, software, modeling, and cost-effective manufacturing
• Well-equipped engineering development and aerosol test laboratory
![Page 5: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/5.jpg)
Manufacturing
• 16,000 sq. ft. facility in a light industrial park in Blaine, Minnesota; half dedicated to Quant Technologies and half to our parent company PEM
• State-of-the-art production areas, raw material storage, prototype machine shop, and analytical chemistry laboratory
• Low to medium volume manufacturing in quantities from 10’s to 100’s annually – PEM volumes of electro-mechanical devices ranges 1,000’s to 10,000’s annually.
• ISO 9001 Quality System with certification on February 5, 2008
• ISO 14644 Class 5 clean room and ASTM D1193, Type 1 Microbiological Grade A water system
![Page 6: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/6.jpg)
Key Employees
• Fred Quant President
• Derek Oberreit Development Engineer
• Laurencia Kyariga Applications Chemist
• Chuck Bille Marketing/Sales/Distribution
• Andrew Amighi CEO
• Jim Blesener CAO and operations support
![Page 7: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/7.jpg)
Acknowledgements
The NQAD development was funded, in part, through an SBIR grant from the National Institutes of Health awarded to Fluid Measurement Technologies, Inc. and Southern Illinois University Carbondale (SIUC)
Quant Technologies wishes to acknowledge the pioneering work of Professor John Koropchak and his colleagues at SIUC
The patented WCPC technology is licensed from Aerosol Dynamics, Inc. US Patent # 6,712,881
![Page 8: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/8.jpg)
What is NQAD?
A new and very different aerosol-based universal HPLC detector
Heart of the instrument is a patented Water Condensation Particle Counter (WCPC)
WCPC technology is well-known and widely used in other scientific fields such as climate research and nanoparticle technology
Nano Quantity Analyte Detector (NQAD) – original work at SIUC in mid-90s
![Page 9: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/9.jpg)
How NQAD Works
Particle numbers not volume or mass
Very Sensitive• like counting photons vs light intensity• like counting electrons vs analog electric current
![Page 10: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/10.jpg)
How NQAD Works
Nebulized Aerosol Distribution• Log Normal• Stable
![Page 11: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/11.jpg)
How NQAD WorksEvaporation• 2-3 order of magnitude shift in particle size• Nonvolatile Residue
![Page 12: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/12.jpg)
How NQAD Works
Size shift of aerosol distribution – basis for aerosol based detectors
![Page 13: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/13.jpg)
How CNLSD WorksWater Condensation Particle Counters
(WCPCs)
Measures the number concentration of very small airborne particles above a minimum size.
Uses water as the condensing fluid – non-toxic, odorless, non-flammable, non-contaminating
•Ultra-sensitive particle size range – from 2.5 nm to over 3 µm diameter
•Wide dynamic concentration range – from 0 to 107 particles/cm3
![Page 14: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/14.jpg)
WCPCWater Condensation Particle Counter• Grows seed particles into droplets
• Supersaturation occurs because of the difference between the thermo and mass diffusivities of water vapor
• Counts Particles – Doesn’t size them
• 6 Order of magnitude counting range
![Page 15: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/15.jpg)
WCPCWater Condensation Particle Counter• Very high signal to noise ratio
![Page 16: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/16.jpg)
WCPCWCPC Detection Efficiency• Stable
![Page 17: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/17.jpg)
How NQAD Works
Low baseline requires ‘clean’ mobile phaseand volatile buffers
NQAD signal based on the particle countrate - #/sec
![Page 18: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/18.jpg)
How NQAD Works
![Page 19: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/19.jpg)
How NQAD Works
![Page 20: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/20.jpg)
NQAD Recap
Nebulization
HPLC column effluent is sprayed into an ultra fine mist of droplets
Droplet size distribution is bell shaped on log scale
![Page 21: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/21.jpg)
NQAD Recap
EvaporationMobile phase and additives evaporate leaving small residue particles
Choice of evaporator temperature ensures evaporation of mobile phase - minimizes evaporation of analyte
Baseline curve – pure mobile phase plus additives
Analyte curve – curve shifts to larger particle size with analyte present
![Page 22: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/22.jpg)
NQAD Recap
WCPC – Condensational Growth
Supersaturated water vapor condenses on particles to form large droplets
Only particles above critical size act as condensation nucleation sites (WCPC Detection Efficiency curve)
Baseline signal is small compared to analyte
Analyte detection down to 1 ng and below possible
![Page 23: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/23.jpg)
NQAD Recap
Optical Detection
Laser optical detector computes the quantity of droplets
Dynamic range is over four orders of magnitude
NQAD signal is particle number concentration as function of time
Peak area under curve represents analyte concentration level
![Page 24: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/24.jpg)
What Makes NQAD Better?
Ultra-high SensitivityExcellent Dynamic Range Good Linearity ReproducibleSmall Size, Robust, ReliableEasy to Set Up and Operate
![Page 25: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/25.jpg)
Ultra-high Sensitivity
Reliably detect from 1 nanogram to 100 micrograms, or more - LOD in the sub-nanogram range
Ideal for searching for drug impurities, degradation products, excipients and when industrial hygiene is a concern
![Page 26: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/26.jpg)
Reproducible Results
NQAD response is stable, precise and reproducible
Example shows six repeated injections of a solution of cations -- the chromatograms are identical
![Page 27: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/27.jpg)
Applications
Analysis of nonvolatile and semivolatile compounds:•Amino acids
•Carbohydrates
•Steroids
•Caffeine
•Cations
•Cholesterol
•Amine
•Artemisinin (ART) and Dihydroartemisinin (DHA)
•PEG 1000 and PEG 20000
•Sulfonic Acid and Sulfanilamide
•Saccharin, Theophylline and Sucrose
•Ovalbumin
•Dipalmitin isomers
Use in a variety of fields including:
•Pharmaceutical
•Environmental
•Agricultural / food / beverage
•Industrial products
•Life sciences
•Energy / petroleum
•Forensics / narcotics
![Page 28: Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008](https://reader035.vdocuments.net/reader035/viewer/2022062301/56649ecb5503460f94bd9bb4/html5/thumbnails/28.jpg)
NQAD
Thank you