Photo above: 12k Envirosafe Fireguard Tank for generator applicaon at VA Hospital Tampa, FL FIREGUARD® Features: Insulates product in tank from ambient temperature variaons, reducing emissions to the environment. Primary and secondary tank can be ghtness tested on-site with standard tesng procedures, unlike other designs. Steel outer wall provides a low cost maintenance and protecon from weathering Primary storage tank and secondary containment compable with a wide variety of fuels and chemicals, including biodiesel and ethanol. Support designs available for all seismic requirements Intersal space can be monitored for leak detecon Meets temperature requirements when the furnace test was extended to 4 hours. Addional Features: Steel construcon allows for recycling Low cost compartments and customizaon Built to naonally recognized STI standards with strict third-party quality control inspecon program Supports designs with engineered hurricane e-downs FIREGUARD® Standards: UL 2085 Listed Protectedtank Balliscs and Impact protecon per UL 2085 Both inner and outer steel tanks are built to UL standards Naonal Fire Protecon Associaon (NFPA) 30 & 30A Internaonal Fire Code (IFC) California Air Resources Board (CARB) Standing Loss Control tesng requirements for air emissions Steel Tank Instute (STI) Standard F941 for Protected Above Ground Storage Tanks Unique Thermal Insulang Material is 75% Lighter than Concrete Available Designs: Horizontal Vercal Rectangular FIREGUARD® double wall fire protected above ground storage tank features an inner and outer steel tank with a unique lightweight thermal insulaon material that exceeds the UL 2-hour fire test. Being 75% lighter than concrete reduces shipping, installaon and relocaon costs. Steel outer tank, secondary containment 3” to 6” of lightweight thermal insulaon Steel inner primary tank MEMCO, Inc. Toll-Free: (800) 555-4754 Email: [email protected] Web: www.abovegroundfuelstoragetanks.com

Upload: others

Post on 05-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: National Fire Protection Association NFPA Available Designs · storage tank features an inner and outer steel tank with a unique lightweight thermal insulation material that exceeds

Photo above: 12k Envirosafe Fireguard Tank for generator application at VA Hospital Tampa, FL

FIREGUARD® Features:

• Insulates product in tank from ambient temperature variations, reducing emissions to the environment.

• Primary and secondary tank can be tightness tested on-site with standard testing procedures, unlike other designs.

• Steel outer wall provides a low cost maintenance and protection from weathering

• Primary storage tank and secondary containment compatible with a wide variety of fuels and chemicals, including biodiesel and ethanol.

• Support designs available for all seismic requirements

• Interstitial space can be monitored for leak detection

• Meets temperature requirements when the furnace test was extended to 4 hours.

Additional Features:

• Steel construction allows for recycling

• Low cost compartments and customization

• Built to nationally recognized STI standards with strict third-party quality control inspection program

• Supports designs with engineered hurricane tie-downs

FIREGUARD® Standards:

• UL 2085 Listed “Protected” tank

• Ballistics and Impact protection per UL 2085

• Both inner and outer steel tanks are built to UL standards

• National Fire Protection Association (NFPA) 30 & 30A

• International Fire Code (IFC)

• California Air Resources Board (CARB) Standing Loss Control testing requirements for air emissions

• Steel Tank Institute (STI) Standard F941 for Protected Above Ground Storage Tanks

• Unique Thermal Insulating Material is 75% Lighter than Concrete

Available Designs:

• Horizontal

• Vertical

• Rectangular

FIREGUARD® double wall fire protected above ground storage tank features an inner and outer steel tank with a unique lightweight thermal insulation material that exceeds the UL 2-hour fire test. Being 75% lighter than concrete reduces shipping, installation and relocation costs.

Steel outer tank,

secondary

containment

3” to 6” of

lightweight thermal

insulation

Steel inner primary

tank

MEMCO, Inc. Toll-Free: (800) 555-4754 Email: [email protected] Web: www.abovegroundfuelstoragetanks.com