TA105202 OptiX NG-SDH ISSUE1.0HUAWEI TECHNOLOGIES CO., LTD.
Fundamentals of communication networks
SDH principle and networking
HUAWEI TECHNOLOGIES CO., LTD.
Tips
This course explains Chapter 1 and Chapter 2 in the OptiX OSN 1500/2500/3500/7500/9500 Command Line Introduction.
This course focuses on Chapter 2 “Command Line Configuration File” in the OptiX OSN 1500/2500/3500/7500/9500 Command Line Introduction.
HUAWEI TECHNOLOGIES CO., LTD.
OptiX OSN 7500 Intelligent Optical Switching System Hardware Description
OptiX OSN 9500 Intelligent Optical Switching System Hardware Description
OptiX NG-SDH Command Line Introduction
HUAWEI TECHNOLOGIES CO., LTD.
After completing this presentation, you should be able to:
Maintain and commission the equipment by using command lines.
Develop and issue a command line batch file for NE configuration.
Run common commands.
Chapter 3 Common Commands
HUAWEI TECHNOLOGIES CO., LTD.
Overview of Command Lines
Here, a command line is a man-machine command issued to Huawei OptiX equipment.
Like the T2000, a command line helps greatly to deploy and maintain Huawei OptiX equipment.
Features:
Easy
Powerful
HUAWEI TECHNOLOGIES CO., LTD.
Version
Application
V3.0
OptiX Metro 3000
OptiX Metro 100/200/500/1050, OptiX 155/622H (V300), OptiX 10GV2, OptiX NG-SDH, OptiX OSN 9500
HUAWEI TECHNOLOGIES CO., LTD.
Inputs and outputs command lines and issues a batch file.
Loads NE software and board software.
Records inputs and outputs automatically.
Download the Navigator at http://support.huawei.com .
Location: Software > Version Software > Optical Network Product Line > Optical Network Tools > Navigator
The Navigator of any version between V5.6 and V6.2 is recommended.
Navigator
Issues a batch file.
Saves results automatically.
Inputs and outputs command lines and issues a batch file.
Does not load NE software or board software.
The cmdterm is self-contained in the T2000. By default, the cmdterm is in the path \T2000\server\Tool\.
Cmdterm
%cmdterm
Placed in the path \T2000\cmdclient\ by default
Applicable to remote maintenance
Set the remote maintenance access license.
Enable the remote maintenance user, remote.
Set the password, operation rights, and validity period.
Run the cmdclient.exe in the \T2000\cmdclient\ path and log in to the cmdclient.
Compared with the Navigator and cmdterm, the cmdclient has the following features:
Is under the control of the T2000 server.
Can create and edit a remote maintenance report.
Cannot download software of the SCC and other boards.
Running the cmdclient
HUAWEI TECHNOLOGIES CO., LTD.
[#neid]:command[:[para_block:] ... [:para_block]]
command: command words
para_block: parameter block. Each parameter block has one or more assignments.
HUAWEI TECHNOLOGIES CO., LTD.
Start of command: ":" (colon)
End of command: ";" (semicolon)
Parameter block separator: ":" (colon)
dbms: a database management system command
sys: a system command
Example: alm-get-curdata:0,0;
Command format
All rights reserved
Command Line Know-How
To query the format of a command, add /? next to the command words.
For example, :alm-get-curdata/?
To query all command words available for the current NE, run the following command:
:help
To retrieve data by keywords, run a command in the following format:
For example, :cfg or :cfg-get
Useful operations
Chapter 3 Common Commands
HUAWEI TECHNOLOGIES CO., LTD.
:per-set-endtime:15m,1990@0@0@0@0@0;
:per-set-endtime:24h,1990@0@0@0@0@0;
:cfg-init-all;
:cfg-set-reqtime:37,5; //To set call-waiting time
:cfg-set-lineused:37,8,1,used; //To set the optical interface for the order wire service
:cfg-set-meetlineused:37,8,1,used; //To set the optical interface for the conference call
//Service configuration
Batch File
In V5.0, the command line software rejects the user and returns NSERR_SM_LOGIN_ALREADY when szhw already logs in to the NE. To forcedly log in, run the following command:
#1:lognew:"szhw","nesoft";
NOTE
1.
#1:login:"szhw","nesoft";
:per-set-endtime:15m,1990@0@0@0@0@0;
:per-set-endtime:24h,1990@0@0@0@0@0;
Function:
These commands end performance monitoring and ensure that configuration rate and data are properly sent to an NE.
Parameter description:
15m: Performance monitoring at the period of 15 minutes
24h: Performance monitoring at the period of 24 hours
1990@0@0@0@0@0: End time of performance monitoring. End performance monitoring as required. To end performance monitoring immediately, set the end time to 1990@0@0@0@0@0.
HUAWEI TECHNOLOGIES CO., LTD.
:cfg-init-all;
Function:
This command initializes an NE to clear all original data from the NE. In this way, the original data does not affect the coming configurations.
Initialize the NE before you configure an NE.
3.
:cfg-set-nename:64,“OSN 3500 example”; //The assignment 64 indicates the length of the NE name.
:cfg-set-nepositon:“1109 room”; //This command is optional.
4.
Enter proper slot numbers and board names.
Precede a board name with ssn1 or ssn2 to indicate whether the board is in series N1 or N2. For example, ssn1gxcsa. For details, see the board number.
HUAWEI TECHNOLOGIES CO., LTD.
Line boards
Tributary boards
Optical amplifier boards
The active SCC is created by default and cannot be deleted. The standby SCC can be manually added or deleted.
An interface board can be added only when its mapping processing board is added.
A logically added board is in one of the following states:
Adding
Active
Deleting
A board is successfully added or deleted only when the addition or deletion is successfully verified.
By default, the PIU, FAN, and AUX/SAP boards are automatically added rather than manually installed.
The CXL1/4/16 boards create logical functional units by logical slot.
HUAWEI TECHNOLOGIES CO., LTD.
:cfg-set-synclass:9,4,0xf001,0x0801,0x0b01,0xf101;
6.
Parameter
Description
Bid
ID of the cross-connect clock board Value range: 9 or 10
SyncNum
HUAWEI TECHNOLOGIES CO., LTD.
:cfg-set-synclass:9,4,0xf001,0x0801,0x0b01,0xf101;
There are four clock sources. Each clock source is numbered in double-byte hexadecimal.
The more significant byte indicates the ID of a line board (0x01–0x11).
The less significant byte indicates the number of an optical interface. The optical interfaces are numbered from 1 on.
The clock sources are numbered as follows:
External clock source 1 is numbered 0xf001.
External clock source 2 is numbered 0xf002.
The internal clock source is numbered 0xf101.
Notes:
Ensure that each line board indicated by the more significant byte is already installed.
End the clock source priority table with the internal clock source.
160x01~0x11110xf00120xf0020xf101

:cfg-set-tellen:37,3; //To set the length of a telephone number
:cfg-set-reqtime:37,5; //To set call-waiting time
:cfg-set-lineused:37,8,1,used; //To set the optical interface for the order wire service
:cfg-set-meetlineused:37,8,1,used; //To set the optical interface for the conference call
Notes:
Ensure that each board indicated by the commands is already installed.
Set the optical interface for the addressing call and that for the conference call separately.
Keep the optical interface for the conference call from a loop.
7.
Precede each command with comments.
In the case of a service terminated at the local site — “//local site – peer site”
In the case of a pass-through service — “//source site – sink site pass through”
To add a VC4 service connection, which runs from VC4 1 on optical interface 1 of slot 15 (source) to VC4 1 on optical interface 1 of slot 8 (sink)
HUAWEI TECHNOLOGIES CO., LTD.
:cfg-verify;
Function:
This command enables the SCC to verify configurations and physical situations. If the verification succeeds, the SCC saves the configurations and notifies the other boards about starting by the configurations. Without the command, the SCC does not issue the configurations to the other boards.
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
To query the state of an NE and to check whether it runs properly
:cfg-get-nestate;
Function:
This command checks whether configurations are successfully issued. If the NE is in the running state, the configurations are successfully issued. If the NE is in the installing state, the configurations fail to be delivered.
Batch File
All rights reserved
To back up the NE database, that is, NE configurations manually
:dbms-copy-all:drdb,fdb0;
:dbms-copy-all:drdb,fdb1;
Function:
These commands prevent fdb0 and fdb1 from being lost due to restart.
Batch File
Chapter 3 Common Commands
HUAWEI TECHNOLOGIES CO., LTD.
Example:
:cfg-get-nestate;
//To query the state of an NE
After verification, an NE must be in the running state rather than in the installing state.
:cfg-get-xc:0,0;
:cfg-get-xc:0,5;
Configuration query
:date(:set-date:2000-2-13)
:time(:set-time:13*00*11)
:cfg-get-phybd
:cfg-get-bdversion:Bid
:cfg-get-bdverinfo:Bid
Other queries
alm-get-curdata:para1,para2;
Parameter description:
para1: ID of a board. To query all boards, set this parameter to 0.
para2: ID of an event. To query all events, set this parameter to 0.
Example:
:alm-get-curdata:0,0;
:alm-get-curdata:11,0;
HUAWEI TECHNOLOGIES CO., LTD.
:alm-get-hisdata:para1,para2;
Parameter description:
para1: ID of a board. To query all boards, set this parameter to 0.
para2: ID of an event. To query all events, set this parameter to 0.
Example:
:alm-get-hisdata:0,0;
Alarm query
:set-time:12*00*00;
:per-set-monevent:0,0,0,0,perall,15m,enable;
Performance monitoring
:per-set-starttime:15m,2005@1@2@3@4@5;
//To set the start time of the performance monitoring at the period of 15 minutes performance
:per-set-starttime:24h,2005@1@2@3@4@5;
//To set the start time of the performance monitoring at the period of 24 hours
Performance monitoring
:lognew:"zhang","pass_word";
:sm-add-user:"user1","my_pass","every",enable;
:logout;
User management
:cm-get-eccroute;
:cm-get-chanerror;
:cm-get-bdinfo;
//To query ECC status on an optical interface of an optical interface board
:cm-get-fiberport:bid,portnum;
//To query the state of an optical interface in an optical interface board, including DCC rate
ECC command
resetmode: Mode of reset
Hard, a cold reset
Soft, a warm reset
A cold reset is thorough but interrupts services.
A warm reset protects services from interruption but is not thorough.
Board reset
:sys-get-nesoftver;
HUAWEI TECHNOLOGIES CO., LTD.
What does a command line configuration file consist of?
In addition to the configuration commands, what commands are commonly used?
Thanks!