nb integration easy guide

16
On site Node B Integration easy guide Page 1 of 16 Prepared by sunthar.murthy Arumugam On site Node B Integration easy guide 1- Change Laptop TCP/IP to IP: 169.254.1.2 (S MASK 255.255.0.0). Note RBS default IP: 169.254.1.1 2- Open Command prompt and ping the NB default IP. If failed please recheck the ip setting. 3- To open EMAS, double click Internet Explore with default IP 169.254.1.1 http://169.254.1.1/em/index_stubbed.html 4- Click Configuration – O&M Access to load the XYZA_OAM_access.xml script. [email protected]

Upload: salimkrimou

Post on 22-Dec-2015

56 views

Category:

Documents


9 download

DESCRIPTION

HOW TO NODE_B INTEGRATION

TRANSCRIPT

Page 1: NB Integration Easy Guide

On site Node B Integration easy guide

Page 1 of 16 Prepared by sunthar.murthy Arumugam

On site Node B Integration easy guide

1- Change Laptop TCP/IP to IP: 169.254.1.2 (S MASK 255.255.0.0). Note RBS default IP: 169.254.1.1

2- Open Command prompt and ping the NB default IP. If failed please recheck the ip setting.

3- To open EMAS, double click Internet Explore with default IP 169.254.1.1 http://169.254.1.1/em/index_stubbed.html 4- Click Configuration – O&M Access to load the XYZA_OAM_access.xml script.

[email protected]

Page 2: NB Integration Easy Guide

On site Node B Integration easy guide

Page 2 of 16 Prepared by sunthar.murthy Arumugam

5- Just follow the onscreen instruction, as below.

Make sure Use configuration file is ticked and select Configuration Automatic (No Wizard) is selected.

[email protected]

Page 3: NB Integration Easy Guide

On site Node B Integration easy guide

Page 3 of 16 Prepared by sunthar.murthy Arumugam

Make sure the result is successful.

Check the O&M Configuration summary.

[email protected]

Page 4: NB Integration Easy Guide

On site Node B Integration easy guide

Page 4 of 16 Prepared by sunthar.murthy Arumugam

[email protected]

Page 5: NB Integration Easy Guide

On site Node B Integration easy guide

Page 5 of 16 Prepared by sunthar.murthy Arumugam

The node b will re-start.

2nd Script (External Hardware) Change PC IP setting according to RBS IP pool (New IP). EX: Node B IP: 10.11.4.9 (Thin Client IP must set to 10.11.4.10) MASK : 255.255.255.248

• Upon successfully loaded the O&M script, go to software management – Configuration Version and right click to create CV. Name this CV as ONM (Your nick name).

[email protected]

• Open Element Manager (EMAS) with RBS new IP and run SITE EQUIPMENT xml file.

Page 6: NB Integration Easy Guide

On site Node B Integration easy guide

Page 6 of 16 Prepared by sunthar.murthy Arumugam

[email protected]

Page 7: NB Integration Easy Guide

On site Node B Integration easy guide

Page 7 of 16 Prepared by sunthar.murthy Arumugam

• Select Automatic (no wizard) • Click on BROWSE and select Site_equipment_config…..xml

[email protected]

Page 8: NB Integration Easy Guide

On site Node B Integration easy guide

Page 8 of 16 Prepared by sunthar.murthy Arumugam

Click on FINISH

[email protected]

Page 9: NB Integration Easy Guide

On site Node B Integration easy guide

Page 9 of 16 Prepared by sunthar.murthy Arumugam

Check list of CV available:

[email protected]

Page 10: NB Integration Easy Guide

On site Node B Integration easy guide

Page 10 of 16 Prepared by sunthar.murthy Arumugam [email protected]

TO CREATE A FINAL CV - Go to SOFTWARE

Right click on Configuration Version (CV) and select CREATE

Page 11: NB Integration Easy Guide

On site Node B Integration easy guide

Page 11 of 16 Prepared by sunthar.murthy Arumugam

Fill in the CV name and Comment. Click APPLY

Click on SET START

[email protected]

Page 12: NB Integration Easy Guide

On site Node B Integration easy guide

Page 12 of 16 Prepared by sunthar.murthy Arumugam

List of CV should be display:

[email protected]

Page 13: NB Integration Easy Guide

On site Node B Integration easy guide

Page 13 of 16 Prepared by sunthar.murthy Arumugam

Right click on the highlighted CV (newly created) and select RELOAD Name this CV as Final_CV_Date

Select YES

[email protected]

Page 14: NB Integration Easy Guide

On site Node B Integration easy guide

Page 14 of 16 Prepared by sunthar.murthy Arumugam

Open Element Manager (EMAS) again to check Antenna status

[email protected]

All ASC and RET status must ENABLED and UNLOCKED.

Page 15: NB Integration Easy Guide

On site Node B Integration easy guide

Page 15 of 16 Prepared by sunthar.murthy Arumugam

[email protected]

Page 16: NB Integration Easy Guide

On site Node B Integration easy guide

Page 16 of 16 Prepared by sunthar.murthy Arumugam

Check Alarm List

[email protected]