NCSX PF Coils 1 NCSX 5/2/06 Michael Kalish NCSX PF Coils

Upload: samson-love

Post on 31-Dec-2015

59 views

Category:

Documents


1 download

DESCRIPTION

NCSX PF Coils. Michael Kalish. NCSX Coil Planar Coils. Upper PF Coils. TF Coils. Lower PF Coils. PF Coils Design. PF4. PF5. PF1. PF6. PF Coil Cross Section. PF Coils of conventional design Rectangular cross section Round Geometry. PF Coil Drawings. - PowerPoint PPT Presentation

TRANSCRIPT

NCSX PF Coils 1

NCSX

5/2/06

Michael Kalish

NCSX PF Coils

NCSX PF Coils 2

NCSX

5/2/06

NCSX Coil Planar Coils

TF Coils

Upper PF Coils

Lower PF Coils

NCSX PF Coils 3

NCSX

5/2/06

PF Coils Design

PF1

PF4PF5

PF6

NCSX PF Coils 4

NCSX

5/2/06

PF Coil Cross Section

• PF Coils of conventional design

• Rectangular cross section

• Round Geometry

NCSX PF Coils 5

NCSX

5/2/06

PF Coil Drawings

•PF Coil drawings are not final but adequate for estimating cost and schedule.

NCSX PF Coils 6

NCSX

5/2/06

PF Coils, Conductor

• A single copper conductor size is used for all four different types of PF coils to simplify their manufacture and reduce costs.

NCSX PF Coils 7

NCSX

5/2/06

Center Stack Assembly, PF1 – PF3

136.8 overall

111.4 windings

• The windings of all three coil pairs are identical; only the lead details differ.

• The solenoid assembly is clamped together by end castings (with 3 electrical breaks) and tie rods.

NCSX PF Coils 8

NCSX

5/2/06

Winding Pack Insulation Design

• Half Lap Layer of Kapton to provide primary dielectric strength

• Three half lap layers of glass are applied on top of the Kapton tape to make up the turn to turn insulation

NCSX PF Coils 9

NCSX

5/2/06

Winding Pack Insulation Design

Turn Insulaton1/2 Lap Layer Kapton Kapton 0.002 7.8

Adhesive 0.0015Kapton 0.002 0

Adhesive 0.0015Glass 0.007 0.63Glass 0.007 0.63Glass 0.007 0.63Glass 0.007 0.63Glass 0.007 0.63Glass 0.007 0.63

0.049 Inches 11.58 KV

• Kapton Tape applied directly to conductor to enhance turn to turn dielectric standoff and allow for decoupling of insulation from conductor during cool down.

• Must withstand maximum of 4KV operating Voltage

NCSX PF Coils 10

NCSX

5/2/06

Clean Room Required to Control Contamination

NCSX PF Coils 11

NCSX

5/2/06

Brazed Joint Technique

• Example of a Typical Brazed Joint

• Sleeve is used with “Sil-Fos” Wafer and 1.5mm diameter ring. to ensure full coverage and no voids

NCSX PF Coils 12

NCSX

5/2/06

Specification Example: C-Spec Electrical Isolation to GroundComponent Definition & Verification

3.2.2.1.4Ground Insulation • The ground insulation is composed of .015 inch thick by two inch wide S2

glass. The S2 glass is applied in half lap layers to bring the total build of the turn to turn insulation to .125 inches at the front leg of the coil and .375 inches around the top, bottom, and back leg of the coil (ref. dwg. SE131-003). The glass and tape thicknesses, width and number of layers may be adjusted to reach the required overall thickness and to facilitate manufacturing requirements with the approval of the WBS manager. Any changes in the groundwrap insulation build up must meet the TF electrical standoff requirements. The number of ground wrap layers is to be optimized so that the compression of the coil in the VPI mold minimizes resin rich areas. Voids in the corners of the VPI mold are to be eliminated with the use of radiused fillers. Measurements and parameters such as the number of layers are to be recorded in the winding procedure for each coil Ref Section 3.2.1.4.1. 4.2.4.1Verification Electrical Isolation to Ground

• The completed coil will be tested at 13.5kV.to ground and to the wedge castings Ref. Section 3.2.1.4.1

NCSX PF Coils 13

NCSX

5/2/06

Manufacturing Procedures Example

• Manufacturing Procedure to provide quality control to guarantee requirements in design specification are met

• Example of Manufacturing Procedure from Modular Coil Winding

• Measurements and signatures required at all critical steps for each coil