CURRENT TRANSFORMERS LOW TENSION BAR PRIMARY (RING TYPE TAPE INSULATED CT ARE SECONDARY COIL WOUND ON TOROIDAL NIPPEN current transformers comply with the highest international quality standards and are made according to BS 3938, CORE OF HIGH PERMEABILITY SILICON STEEL) Is2705 or IEC185. CT's are available in BPCT & WPCT rated Volt. 660V, Sec Current 5A or 1A In BPCT current range is 100A-3000A , in WPCT below A,Rated Burden 30VA . 75 1VA- RING ID OD HT ACCURACY VA BURDEN 50/5 33 66 36 5% 3 60/5 33 66 36 5% 3 75/5 33 66 36 5% 3 100/5 33 66 36 1.0% 5 150/5 33 66 36 1.0% 5 200/5 33 66 36 1.0% 5 300/5 60 100 36 1.0% 10 400/5 60 100 36 1.0% 10 500/5 60 100 36 1.0% 10 600/5 60 100 36 1.0% 10 RING ID OD HT ACCURACY VA BURDEN 800/5 80 100 35 1.0% 10 1000/5 80 100 35 1.0% 15 1200/5 80 100 35 1.0% 15 1500/5 100 135 35 1.0% 15 1600/5 100 135 35 1.0% 15 2000/5 100 135 35 1.0% 15 2500/5 100 135 35 1.0% 15 3000/5 100 135 35 1.0% 15 TYPE RATIO WINDOW DIMENSIONS FOR BUS BAR (MM) OVERALL DIMENSION (HXWXTH) 201 100/5A---------500/5A 20MM 70X55X45 301 75/5A---------400/5A 30X10 70X49X32 401 150/5A---------600/5A 40X12.5 78X60X32 501 300/5A---------1250/5A 51X11 92X85X32 601 400/5A---------1600/5A 60X10 108X85X32 801 400/5A---------2000/5A 80X10 122X100X40 1001 800/5A---------3000/5A 100X30 160X135X40 FR grade ABS housing sonic welded Temperature rating -10 C to 70 C class E 0 Frequency 50/60HZ 0 Nominal Voltage 660V AC Dielectric strength 3 KV/ 1min Rated short time thermal current I 60 I th= n CURRENT TRANSFORMERS ABS RING TAPE WOUND (RING CT) SQUARE CT MODEL (NE SERIES) NIPPEN ELECTRICAL INSTRUMENTS CO 12-A, Joy Engg Compound, Marol Maroshi Road,Andheri(E), Mumbai-400059, India. Tele : 022 -29201581/1806/29253164. E-mail: [email protected], Visit us at: www.nippenco.com TYPE Tested at ERTL as per IS2705

Upload: others

Post on 06-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NE Ct dimension - Crescent Electricalscrescentelectricals.com/.../energy-meters-catalogue/NECT.pdfCURRENT TRANSFORMERS LOW TENSION BAR PRIMARY (RING TYPE TAPE INSULATED CT ARE SECONDARY

CURRENT TRANSFORMERS LOW TENSION BAR PRIMARY (RING TYPE TAPE INSULATED CT ARE SECONDARY COIL WOUND ON TOROIDAL

NIPPEN current transformers comply with the highest international quality standards and are made according to BS 3938,

CORE OF HIGH PERMEABILITY SILICON STEEL)

Is2705 or IEC185. CT's are available in BPCT & WPCT rated Volt. 660V, Sec Current 5A or 1A In BPCT current range is 100A-3000A

, in WPCT below A,Rated Burden 30VA .75 1VA-

RING ID OD HT ACCURACY VA BURDEN

50/5 33 66 36 5% 3

60/5 33 66 36 5% 3

75/5 33 66 36 5% 3

100/5 33 66 36 1.0% 5

150/5 33 66 36 1.0% 5

200/5 33 66 36 1.0% 5

300/5 60 100 36 1.0% 10

400/5 60 100 36 1.0% 10

500/5 60 100 36 1.0% 10

600/5 60 100 36 1.0% 10

RING ID OD HT ACCURACY VA BURDEN

800/5 80 100 35 1.0% 10

1000/5 80 100 35 1.0% 15

1200/5 80 100 35 1.0% 15

1500/5 100 135 35 1.0% 15

1600/5 100 135 35 1.0% 15

2000/5 100 135 35 1.0% 15

2500/5 100 135 35 1.0% 15

3000/5 100 135 35 1.0% 15

TYPE RATIOWINDOW DIMENSIONS

FOR BUS BAR (MM)

OVERALL DIMENSION

(HXWXTH)

201 100/5A---------500/5A 20MM 70X55X45

301 75/5A---------400/5A 30X10 70X49X32

401 150/5A---------600/5A 40X12.5 78X60X32

501 300/5A---------1250/5A 51X11 92X85X32

601 400/5A---------1600/5A 60X10 108X85X32

801 400/5A---------2000/5A 80X10 122X100X40

1001 800/5A---------3000/5A 100X30 160X135X40

FR grade ABS housing sonic welded

Temperature rating -10 C to 70 C class E0

Frequency 50/60HZ

0

Nominal Voltage 660V AC

Dielectric strength 3 KV/ 1min

Rated short time thermal current I 60 Ith= n

CURRENT TRANSFORMERS

ABS RING

TAPE WOUND (RING CT)

SQUARE CT MODEL (NE SERIES)

R

NIP

PEN

ELEC

TR

ICA

L IN

ST

RU

MEN

TS C

O12-A

, Joy E

ngg C

om

pound,

Maro

l M

aro

shi R

oad,A

ndheri

(E),

Mum

bai-

400059,

India

.

Tele

: 0

22 -

29201581/1

806/2

9253164.

E-m

ail:

sal

es@

nip

penco

.com

, V

isit

us

at:

ww

w.n

ippenco

.com

R

TYPE Tested at ERTL as per IS2705