NetCom THDATA SHEET
Contact Closure Version
The NetCom TH is an Ethernet compatible network interface device that is intended to be used as aremote monitor of Uninterruptible Power Supplies (UPS) using SNMP. Additionally NetCom TH also
supports Web based communications and it is shipped with its own monitoring / managementsoftware tool.
The NetCom TH can be attached to a number of UPS volt free contact alarms to allow a networksupervisor to monitor via SNMP protocol (Simple Network management protocol) over TCP/IPnetworks using popular network management platforms such as HP OpenView, SunNet Manager,Castle Rock SNMPc etc. An optional temperature/humidity sensor can also be connected to NetComTH for remote monitoring purposes.
This monitoring functionality is summarised below:
• Up to 7 x digital inputs
• 1 x Temp/Humidity sensor input
• Java SNMP agent viewer (like a mini NMS)
•HTML configuration support (web browser)
• Optional 48 volt power input
NOTES ON TEXTPlease note that the NetCom TH adaptor has been principally designed for use with a UPS, however it can be used with any contact closure signaling device such as an Air Conditioning unit, BMS nodeor AC generator. Therefore the text “UPS” used within this document can also be read as “AnyContact Closure Device”.
![Page 2: NetComTHCC_Datasheet](https://reader035.vdocuments.net/reader035/viewer/2022081807/577cd7a11a28ab9e789f76ad/html5/thumbnails/2.jpg)
7/27/2019 NetComTHCC_Datasheet
http://slidepdf.com/reader/full/netcomthccdatasheet 2/3
SINET ICALink to the network
Extending the reach of yourNetwork Management System
Sinetica Corporation Ltd.Singleton Court
Wonastow Road Industrial EstateMonmouth. NP25 5JA
Tel: 01600 716400Fax: 01600 772026
Email: [email protected]: http://www.sinetica.co.uk
Technical Data – June 2003
VAT Reg. No. GB 542 8088 34Reg. No. 2623558
Dimensions Layout and dimensions for the NetCom TH are shown in Figure 1.
Height = 30mm (without feet), 32mm (with feet)
Hardware Interface Description – Port 1
Pin # Name Description Input #
1 DCD Data Carrier Detect 3
2 RXD Receive 1
3 TXD Transmit
4 DTR Data Terminal Ready
5 GND Ground6 DSR Data Set Ready 5
7 RTS Request To Send
8 CTS Clear To Send 2
9 RI Ring Indicator 4
This port can be used to monitor up to 5 contact closure signals
Hardware Interface Description – Port 2 used for temp/humidity communications in Fig 1:
Pin # Name Description Input #
1 DCD Data Carrier Detect 6
2 RXD Receive 7
3 TXD Transmit
4 DTR Data Terminal Ready
5 GND Ground
6 VCC +5v 5 volt drive for Analogue input
7 Analogue In Temperature Input
8 GND Ground
9 Analogue In Humidity Input
This port can be used to monitor up to 2 contact closure signals in addition to temperature andhumidity.
Port 1D9 RS232
Port 2D9 Temp/Humidity
5VDC Power Connector
10 Base TConnector
DIP switch
148.60 mm
90mm 41.25mm
Figure 1Power LED
RS232LED
NetworkLED
StatusLED
![Page 3: NetComTHCC_Datasheet](https://reader035.vdocuments.net/reader035/viewer/2022081807/577cd7a11a28ab9e789f76ad/html5/thumbnails/3.jpg)
7/27/2019 NetComTHCC_Datasheet
http://slidepdf.com/reader/full/netcomthccdatasheet 3/3
SINET ICALink to the network
Extending the reach of yourNetwork Management System
Sinetica Corporation Ltd.Singleton Court
Wonastow Road Industrial EstateMonmouth. NP25 5JA
Tel: 01600 716400Fax: 01600 772026
Email: [email protected]: http://www.sinetica.co.uk
Technical Data – June 2003
VAT Reg. No. GB 542 8088 34Reg. No. 2623558
OPERATING DATA
Digital inputs 7 x inputs to detect a volt free dry contact (pulled up to RS-232 level)
Temp/Humidity port Measurement range 30% to 90% relative humidity, 0°c to 60°c temp
Accuracy +/-5%rh (@ 25°c, 60%rh), +/-0.7°c (@ 25°c)
Communication SNMP monitoring / management
Telnet managementJAVA monitoring/management applet (“Viewer”)WEB managementTerminal configuration
RS232 Port RS2332 for local configuration.
Security Telnet and WEB access password protection.
Upgradeability Firmware upgradeable using serial download or TFTP download.
Standards andCertifications
CE
PHYSICAL
Kit contents Unit, config cable, CD, mains adaptor PSU, carton
Enclosure Steel case with epoxy powder coating90mm wide x 149mm deep and 32mm high0.3 Kg weight
LED indicators DC Power OnStatusNetwork trafficRS-232
Power input 1 x jack plug +5v DC
Serial config port D9 male port 1
Temp/humidity port D9 female port 2
Digital input port D9 male port 1 and D9 female port 2
LAN port RJ45 way socket 10 BaseTNormal power usage 300 mA
Maximum power 400 mA
Input protection Polyfuse
Operating range 0 ~ 40°C
Operating humidity 5 ~ 90%
Storage temperature -10 ~ 70°C
Storage humidity 5 ~ 100%