NetEnforcer AC-800 Series

Hardware Guide

P/N D361001 R2

Page 4: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose
Page 5: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Important Notice

AC-800 Series Hardware Guide iii

Important Notice Allot Communications Ltd. ("Allot") is not a party to the purchase agreement under which NetEnforcer was purchased, and will not be liable for any damages of any kind whatsoever caused to the end users using this manual, regardless of the form of action, whether in contract, tort (including negligence), strict liability or otherwise. SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE, AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ALLOT OR ANY OF ITS SUBSIDIARIES. ALLOT ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS MANUAL, INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT. Please read the End User License Agreement and Warranty Certificate provided with this product before using the product. Please note that using the products indicates that you accept the terms of the End User License Agreement and Warranty Certificate. WITHOUT DEROGATING IN ANY WAY FROM THE AFORESAID, ALLOT WILL NOT BE LIABLE FOR ANY SPECIAL, EXEMPLARY, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND, REGARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY OR OTHERWISE, INCLUDING, BUT NOT LIMITED TO, LOSS OF REVENUE OR ANTICIPATED PROFITS, OR LOST BUSINESS, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

Copyright Copyright © 1997-2007 Allot Communications. All rights reserved. No part of this document may be reproduced, photocopied, stored on a retrieval system, transmitted, or translated into any other language without a written permission and specific authorization from Allot Communications Ltd.

Trademarks Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identification or explanation and to the owners' benefit, without intent to infringe. Allot and the Allot Communications logo are registered trademarks of Allot Communications Ltd.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Changes or modifications not expressly approved by Allot Communication Ltd. could void the user's authority to operate the equipment.

Page 6: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Important Notice

AC-800 Series Hardware Guide iv

Printing History

First Edition: August, 2006

Second Edition: September, 2007

Page 7: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

NetEnforcer AC-800 Hardware Guide v

TABLE OF CONTENTS Important Notice .......................................................................................................................... iii Printing History ............................................................................................................................. iv 

CHAPTER 1: AC-800 SERIES HARDWARE ........................................................... 1-1 AC-800 Series Packing List ....................................................................................................... 1-2 AC-800 Series Front Panel ........................................................................................................ 1-3 

AC-802 Front Panel .................................................................................................................. 1-4 AC-804 Front Panel .................................................................................................................. 1-5 AC-808 Front Panels ................................................................................................................ 1-6 AC-800 Series LCD Panel ........................................................................................................ 1-8 

AC-800 Series Rear Panel .......................................................................................................... 1-9 AC-800 Series Power Supply ................................................................................................. 1-10 

Cabling ...................................................................................................................................... 1-13 AC-800 Series Copper ............................................................................................................ 1-13 AC-802/804 Multi Mode (SX) Fiber ...................................................................................... 1-14 AC-808 Multi Mode (SX) Fiber ............................................................................................. 1-15 AC-800 Series Single Mode (LX) Fiber ................................................................................. 1-16 Connectors .............................................................................................................................. 1-17 

Bypass Units .............................................................................................................................. 1-18 AC-802 Bypass Units ............................................................................................................. 1-18 AC-804 Bypass Unit ............................................................................................................... 1-22 AC-808 Bypass Unit ............................................................................................................... 1-27 

Powering Up ............................................................................................................................. 1-30 Connection to AC Power ........................................................................................................ 1-30 Connection to DC Power ........................................................................................................ 1-31 Grounding ............................................................................................................................... 1-32 Powering Up Via LCD Panel ................................................................................................. 1-33 

CHAPTER 2: PLACEMENT IN THE NETWORK .................................................. 2-1 

CHAPTER 3: SETTING UP THE NETENFORCER ................................................ 3-1 Configuring Via a Terminal or Telnet ...................................................................................... 3-1 

Page 8: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

NetEnforcer AC-800 Hardware Guide vi

Configuring Via the LCD Panel .............................................................................................. 3-12 Getting Started on NetEnforcer ............................................................................................... 3-12 Activating Bypass ................................................................................................................... 3-14 Rebooting, Shutting Down and Exiting the NetEnforcer ........................................................ 3-15 

CHAPTER 4: REDUNDANCY .................................................................................... 4-1 Enabling Redundancy ................................................................................................................ 4-1 Parallel Redundancy ................................................................................................................ 4-13 

Status Indicators in Parallel Redundancy Mode ..................................................................... 4-14 Secondary NetEnforcer Activation ......................................................................................... 4-15 

Active Redundancy ................................................................................................................... 4-17 Failover ................................................................................................................................... 4-17 Policy Configuration ............................................................................................................... 4-17 Connecting the NetEnforcer in Active Redundancy ............................................................... 4-18 Active Redundancy for the AC-804 ........................................................................................ 4-18 Active Redundancy for the AC-808 ........................................................................................ 4-19 

Serial Redundancy .................................................................................................................... 4-21 NetEnforcer Failover............................................................................................................... 4-22 Serial Redundancy in Mesh Topologies ................................................................................. 4-23 

CHAPTER 5: HARDWARE SPECIFICATIONS ..................................................... 5-1 Dimensions ............................................................................................................................... 5-1 Power Requirements ................................................................................................................. 5-1 Operating Environment ............................................................................................................. 5-2 

Standards, Compliance and Certifications ............................................................................... 5-2 

CHAPTER 6: FIREWALL PORT REFERENCE ..................................................... 6-1 Basic Management ...................................................................................................................... 6-1 NetXplorer ................................................................................................................................... 6-2 

CHAPTER 7: ÉQUIPEMENT DE SÉRIE AC-800 ................................................... 7-1 Mises en garde d’ordre général ................................................................................................. 7-1 Remarques d’ordre général ....................................................................................................... 7-3 Spécifications matérielles ........................................................................................................... 7-4 

Page 9: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

NetEnforcer AC-800 Hardware Guide vii

Dimensions ............................................................................................................................... 7-4 Spécifications requises ............................................................................................................... 7-4 

Alimentation ............................................................................................................................. 7-4 Conditions ambiantes ............................................................................................................... 7-4 

Page 10: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

NetEnforcer AC-800 Hardware Guide viii

TABLE OF FIGURES

Figure 1-1 – NetEnforcer AC-800 Series Front Panel (Model AC-802 Copper) ......................... 1-3 

Figure 1-2 – Front Panel: AC-802 Copper ................................................................................... 1-4 

Figure 1-3 – Front Panel: AC-802 Fiber ....................................................................................... 1-4 

Figure 1-4 – Front Panel: AC-804 Copper ................................................................................... 1-5 

Figure 1-5 – Front Panel: AC-804 Fiber ....................................................................................... 1-5 

Figure 1-6 – Front Panel: AC-808 Copper ................................................................................... 1-6 

Figure 1-7 – Front Panel: AC-808 Fiber ....................................................................................... 1-6 

Figure 1-8 – NetEnforcer LCD Panel: AC-800 Series ................................................................. 1-8 

Figure 1-9 – NetEnforcer Rear Panel: AC-800 Series .................................................................. 1-9 

Figure 1-10 – NetEnforcer AC Power Supply: AC-800 Series .................................................. 1-10 

Figure 1-11 – NetEnforcer DC Power Supply: AC-800 Series .................................................. 1-11 

Figure 1-12 – Dual SC Connector .............................................................................................. 1-17 

Figure 1-13 – Dual LC Connector .............................................................................................. 1-17 

Figure 1-14 – Single Copper Bypass Unit .................................................................................. 1-18 

Figure 1-15 – Connecting the NetEnforcer AC-802 Copper to the Single Copper Bypass Unit 1-19 

Figure 1-16 –Single Fiber Bypass Unit – Multi Mode ............................................................... 1-20 

Figure 1-17 –Single Fiber Bypass Unit – Single Mode .............................................................. 1-20 

Figure 1-18 – Connecting NetEnforcer AC-802 Fiber to Single Fiber Bypass Unit – Multi Mode ............................................................................................................................................ 1-21 

Figure 1-19 – Connecting the NetEnforcer AC-804 to Double Copper Bypass Unit................. 1-23 

Figure 1-20 – Double Fiber Bypass Unit - MultiMode .............................................................. 1-24 

Page 11: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

NetEnforcer AC-800 Hardware Guide ix

Figure 1-21 – Double Fiber Bypass Unit – Single Mode ........................................................... 1-25 

Figure 1-22 – Connecting the NetEnforcer AC-804 to Double Fiber Bypass Unit – Single Mode 1-26 

Figure 1-23 – Multi-Port Copper Bypass Unit ........................................................................... 1-28 

Figure 1-24 – Multi-Port Fiber Bypass Unit .............................................................................. 1-29 

Figure 3-1 – NetEnforcer Setup Menu ......................................................................................... 3-2 

Figure 3-2 – Current Configuration (1) ........................................................................................ 3-4 

Figure 3-3 – Current Configuration (2) ........................................................................................ 3-5 

Figure 3-4 – Network Configuration ............................................................................................ 3-6 

Figure 3-5 – Password .................................................................................................................. 3-9 

Figure 3-6 – Time Setup............................................................................................................. 3-10 

Figure 4-1 – NIC Tab AC-802 – NetXplorer Configuration ........................................................ 4-3 

Figure 4-2 – Networking Tab AC-802 – NetXplorer Configuration ........................................... 4-4 

Figure 4-3 – NIC Tab AC-804 – NetXplorer Configuration ........................................................ 4-7 

Figure 4-4 – Networking Tab AC-804 – NetXplorer Configuration ........................................... 4-8 

Figure 4-5 – NIC Tab AC-808 – NetXplorer Configuration ...................................................... 4-11 

Figure 4-6 – Networking Tab AC-808 – NetXplorer Configuration ......................................... 4-12 

Figure 4-7 – Active redundancy using AC-804 ......................................................................... 4-18 

Figure 4-8 – Active Redundancy using AC-808 ........................................................................ 4-19 

Figure 4-9 – Serial Redundancy – Normal Scenario .................................................................. 4-21 

Figure 4-10 – Serial Redundancy – Failover Scenario ............................................................... 4-22 

Figure 4-11 – Serial Redundancy – Bypass Scenario ................................................................ 4-23 

Figure 4-12 – Serial Redundancy – Mesh Scenario ................................................................... 4-24 

Page 12: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose
Page 13: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

NetEnforcer AC-800 Hardware Guide 1-1

Chapter 1: AC-800 Series Hardware

The Allot NetEnforcer AC-800 Series enables the definition and classification of traffic by users, applications and resources. Several NetEnforcer AC-800 models are available to support large and small sites and different data network speeds.

Each model type has a different number of ports to accommodate different requirements:

• AC-802: Two Ports, 1 Line

• AC-804: Four Ports, 2 Lines

• AC-808: Eight Ports, 4 Lines

All NetEnforcer AC-800 series units support

• 256,000 connections (512,000 flows)

• 2,048 Pipes

• 8,192 Virtual Channels

Additional Pipes and Virtual Channels can also be purchased separately per device. Allot basic management software is included with all AC-800 series devices. Allot NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management.

The NetEnforcer AC-802 is a general-purpose device with one line (two port) connectivity for small or medium sized enterprises. The device is available with either AC or DC power supplies and with copper, SX fiber or LX5 fiber. The AC-802 may be ordered with an upgradable throughput of 54Mbps, 100 Mbps, 155 Mbps or 310 Mbps.

The NetEnforcer AC-804 is intended to be used in medium sized or large enterprise networks that require the ability to handle dual network segments. The AC-804 has two line (four port) connectivity. The device is available with either AC or DC power supplies and with copper, SX fiber or LX5 fiber. The AC-804 may be ordered with an upgradable throughput of 54Mbps, 100 Mbps, 155 Mbps or 310 Mbps.

Page 14: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-2

The NetEnforcer AC-808 is a four line (eight port) unit intended for large enterprise networks or small service providers/carriers. The device is available with either AC or DC power supplies and with copper, SX fiber or LX5 fiber. The AC-808 may be ordered with an upgradable throughput of 54Mbps, 100 Mbps, 155 Mbps or 310 Mbps.

The NetEnforcer AC-800 Series offers redundant critical components for fail-safe operation. Redundant hardware components on the AC-800 Series include redundant fans and dual hot-swappable power supplies.

These platforms come with an additional module known as a Copper Bypass or a Fiber Bypass (depending on the interface type). These Units are external Bypass switches.

CAUTION All AC-800 Series models only function when the appropriate Bypass Unit is connected to it. This is to ensure continuous service in the event of failure.

AC-800 Series Packing List Verify that the following items are included with NetEnforcer:

• NetEnforcer (hardware with pre-installed software) • NetEnforcer Hardware Guide • Three mains power cables according to National Electrical Code (NEC) with

molded IEC sockets • Bypass Cables (number and specifications depends upon model and interface

type) • 1 Serial Console Cable • 1 Management Cable • 2 Side Mounting Brackets • DB-9 Parallel Redundancy Cable

A DB-9 Serial Redundancy Cable (P/N C411012) may be ordered from Allot.

All NetEnforcer models contain a lithium battery on the main board.

Page 15: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-3

CAUTION Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.

AC-800 Series Front Panel The front panels of AC-800 Series models include the following ports:

• Network Connectors (Internal and External) • Management Port • Console Connecter • Backup (9-pin D-type) Connector

Management of the NetEnforcer AC-800 Series can be via the Management port or network connectors.

NetEnforcer connects to your network via connectors located on the front panel. These connectors and the LED indicators on the front panel are shown below:

Figure 1-1 – NetEnforcer AC-800 Series Front Panel (Model AC-802 Copper)

Page 16: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-4

AC-802 Front Panel

Figure 1-2 – Front Panel: AC-802 Copper

Figure 1-3 – Front Panel: AC-802 Fiber

Page 17: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-5

AC-804 Front Panel

Figure 1-4 – Front Panel: AC-804 Copper

Figure 1-5 – Front Panel: AC-804 Fiber

Page 18: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-6

AC-808 Front Panels

Figure 1-6 – Front Panel: AC-808 Copper

Figure 1-7 – Front Panel: AC-808 Fiber

CAUTION CLASS 1 LASER PRODUCT. DANGER! Invisible laser radiation when opened. AVOID DIRECT EXPOSURE TO BEAM.

Page 19: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-7

The front panel of the AC-800 Series contains LEDs that are positioned on each of the External, Internal and Management connectors or used as the Standby, Active and Power indicators.

The modes of operation of the External, Internal and Management indicators are described in the table below.

Extrnl/Intrnl/Mngmt NetEnforcer Status Green A link is detected.

Orange Blinks when traffic is detected on the interface.

Off No link activity is detected.

Table 1-1 – External/Internal/Management LED Conditions: AC-800 Series

The modes of operation of the Standby, Active and Power indicators are described in the table below.

Indicator Status NetEnforcer Status

Standby On Two NetEnforcers are connected in Parallel Redundancy mode and this NetEnforcer is the secondary system.

Off If you have one NetEnforcer, this should be the normal state of the LED. If you have two NetEnforcers configured in Redundancy mode, this NetEnforcer is not in standby.

Active On The NetEnforcer is in Active mode. Off The NetEnforcer is in Bypass mode. Traffic passes

through the NetEnforcer with no Quality of Service or traffic shaping. If you have two NetEnforcers configured in Parallel Redundancy mode, this is the secondary NetEnforcer in a Parallel Redundancy configuration and it is not active (In the other NetEnforcer this LED should be on).

Page 20: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-8

Indicator Status NetEnforcer Status

Power On The NetEnforcer is powered up. Off The NetEnforcer is shut down.

Table 1-2 – Standby/Active/Power LED Conditions: AC-800 Series

AC-800 Series LCD Panel The LCD panel provides an indication of traffic usage and enables you to configure the NetEnforcer directly without connecting a terminal.

On/Off Enter

Up Arrow

Display Area

Select

Power Indicator

Active Indicator

Standby Indicator

Left Arrow

Right Arrow

Down Arrow

On/Off Enter

Up Arrow

Display Area

Select

Power Indicator

Active Indicator

Standby Indicator

Left Arrow

Right Arrow

Down Arrow

Figure 1-8 – NetEnforcer LCD Panel: AC-800 Series

For a description of how to configure the NetEnforcer using the LCD panel, refer to Configuring Via the LCD Panel, page 3-12.

Management Port The dedicated Management port on all NetEnforcer models enables out-of-band management of the device. Operating through the Management port increases security by denying access to the device via the Internal or External ports. Moreover, when there is a problem in the regular network it is still possible to manage and monitor the NetEnforcer.

Page 21: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-9

AC-800 Series Rear Panel The rear panel of the AC-800 Series contains the following:

• Grounding Screw • Three Hot-swappable Power Supplies

Figure 1-9 – NetEnforcer Rear Panel: AC-800 Series

Page 22: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-10

AC-800 Series Power Supply The NetEnforcer AC-800 Series includes three hot-swappable power supply modules and a dual line feed for Redundancy purposes. Each line feed drives one power supply. It is possible for the unit to operate normally with only two of the three power supplies active, if necessary.

NOTE The power supply automatically adapts to voltages between 100 V and 240 V, 50/60 Hz.

Should it be necessary, the power supplies can be replaced while the NetEnforcer is connected and in operation. Replacing a power supply while the unit is in operation is possible since the remaining power supply will take the full load and maintain full operation.

Figure 1-10 – NetEnforcer AC Power Supply: AC-800 Series

Page 23: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-11

Figure 1-11 – NetEnforcer DC Power Supply: AC-800 Series

NOTE AC Power Supply modules and DC Power Supply modules are interchangeable.

CAUTION This equipment has a connection between the earthed conductor of the DC supply circuit and the earthing conductor. Before connecting the product to the power line, make sure that the protective ground terminal of the device is connected to the safety ground conductor of the mains power cord. The mains plug should only be inserted in a socket outlet provided with a connected safety ground. The protective action must not be negated by use of an extension cord (power cable) without a protective conductor (grounding). Any interruption of the protective (grounding) conductor or disconnection of the protective ground terminal can make the device unsafe to use. Intentional interruption is prohibited.

Page 24: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-12

To remove a power supply module, press the release button, pull the handle and slide the module out. Leave the power cord connected when removing a power supply module.

Each power supply has a two color power LED indicating input/output power status:

LED Power Supply Status Green Indicates that the power supply is connected to power and is

functioning.

Red Indicates that the power supply has failed.

When power failure occurs, the power LED indication turns Red and an internal buzzer sounds. The power supply module must be removed to silence the buzzer. Leave the power cord connected when removing a power supply module.

CAUTION The power entry modules (AC supply option) include two fuses (T2A 250 V, 5 x 20 mm) at each power entry. One is a spare fuse for replacement purposes. You can open the fuse box and change when necessary. For continued protection against risk of fire, replace only with same type and rating of fuse.

Disconnect the product from the power line before removing the cover. Any adjustment and maintenance of the opened device should be done only while the device is disconnected from its source of power and should only be performed by qualified personnel

Key features of the power supply include: • Hot-pluggable, easy to maintain • Based on the N+1, load sharing • Universal AC input with Power Factor correction • Rear panel with bi-color LED indicating input/output power status • Power fault buzzer alarm system

Page 25: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-13

Cabling AC-800 Series Copper

NOTE Ethernet Cables may be Straight or Cross, depending upon your network. For those Ethernet cables which are included with the NetEnforcer, see AC-800 Series Packing List on p. 1-2 for type details. Shielded cables must be used in order to insure compliance.

Connections Cable Type Connector Type

To NetEnforcer Management Port

Ethernet (Cat-6) (Included, P/N C411011) RJ-45

To NetEnforcer Console Port

Ethernet (Cat-6) (Included, P/N C002005B) RJ-45

Primary NetEnforcer Internal/Eternal to Bypass Unit Internal/External

Ethernet (Cat 6) (Included, P/N C411008 x2) RJ-45

Secondary NetEnforcer Internal/External to Network

Ethernet (Cat 6) RJ-45

NetEnforcer Backup Connector to Bypass Unit

DB-9 Cable (Included, P/N C702001) D-Type 9-Pin

Bypass Unit Internal to Switch Ethernet (Cat 6) RJ-45

Bypass Unit External to Router Ethernet (Cat 6) RJ-45

Page 26: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-14

AC-802/804 Multi Mode (SX) Fiber NOTE Ethernet Cables may be Straight or Cross, depending upon your network.

For those Ethernet cables which are included with the NetEnforcer, see AC-800 Series Packing List on p. 1-2 for type details.

Connections Cable Type Connector Type

To NetEnforcer Management Port

Ethernet (Cat-6) (Included, P/N C411011) RJ-45

To NetEnforcer Console Port

Ethernet (Cat-6) (Included, P/N C002005B) RJ-45

Primary NetEnforcer to Bypass Unit (Internal/External)

Built In Built In

NetEnforcer Backup Connector to Bypass Unit

DB-9 Cable (Included, P/N C702001) D-Type 9-Pin

Secondary NetEnforcer to Network (Internal/External)

62.5/125μ fiber optic cable Dual SC

Bypass Unit Internal to Switch 62.5/125μ fiber optic cable Dual SC

Bypass Unit External to Router 62.5/125μ fiber optic cable Dual SC

Page 27: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-15

AC-808 Multi Mode (SX) Fiber NOTE Ethernet Cables may be Straight or Cross, depending upon your network.

For those Ethernet cables which are included with the NetEnforcer, see AC-800 Series Packing List on p. 1-2 for type details.

Connections Cable Type Connector Type

To NetEnforcer Management Port

Ethernet (Cat-6) (Included, P/N C411011) RJ-45

To NetEnforcer Console Port

Ethernet (Cat-6) (Included, P/N C002005B) RJ-45

Primary NetEnforcer to Bypass Unit (Internal/External)

9/125μ fiber optic cable (Included, P/N C411014 x2)

Dual LC

NetEnforcer Backup Connector to Bypass Unit

DB-9 Cable (Included, P/N C702001) D-Type 9-Pin

Secondary NetEnforcer to Network (Internal/External)

9/125μ fiber optic cable Dual LC

Bypass Unit Internal to Switch 9/125μ fiber optic cable Dual LC

Bypass Unit External to Router 9/125μ fiber optic cable Dual LC

Page 28: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-16

AC-800 Series Single Mode (LX) Fiber NOTE Ethernet Cables may be Straight or Cross, depending upon your network.

For those Ethernet cables which are included with the NetEnforcer, see AC-800 Series Packing List on p. 1-2 for type details.

Connections Cable Type Connector Type

To NetEnforcer Management Port

Ethernet (Cat-6) (Included, P/N C411011) RJ-45

To NetEnforcer Console Port

Ethernet (Cat-6) (Included, P/N C002005B) RJ-45

Primary NetEnforcer to Bypass Unit (Internal/External)

9/125μ fiber optic cable (Included, P/N C411015) Dual LC

NetEnforcer Backup Connector to Bypass Unit

DB-9 Cable (Included, P/N C702001) D-Type 9-Pin

Secondary NetEnforcer to Network (Internal/External)

9/125μ fiber optic cable Dual LC

Bypass Unit Internal to Switch 9/125μ fiber optic cable Dual LC

Bypass Unit External to Router 9/125μ fiber optic cable Dual LC

Page 29: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-17

Connectors NetEnforcer Single and Double Bypass Units using Multi Mode fiber (SX) utilizes dual SC Connectors.

Figure 1-12 – Dual SC Connector

NetEnforcer Single and Double Bypass Units using Single Mode fiber (LX) and all Multi-Port Bypass Units utilize dual LC connectors.

Figure 1-13 – Dual LC Connector

NOTE Color and appearance of actual connectors may vary.

Page 30: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-18

Bypass Units The AC-800 Series operates with an external Bypass Unit. The Bypass Unit is a mission-critical subsystem designed to ensure network connectivity at all times. The Bypass mechanism provides ‘connectivity insurance’ in the event of a NetEnforcer subsystems failure. AC-800 Series Copper units operate with a Copper Bypass and AC-800 Fiber units operate with a Fiber Bypass. The AC-802 requires the Single Bypass Unit while the AC-804 requires a Double Bypass Unit and the AC-808 requires a Multi-port Bypass Unit. Bypass Units are connected to NetEnforcer by a series of leads and cables.

CAUTION All AC-800 Series models only function when the appropriate Bypass Unit is connected to it. This is to ensure continuous service in the event of failure.

AC-802 Bypass Units

Single Copper Bypass Unit The Single Copper Bypass Unit works in conjunction with NetEnforcer AC-802 Copper models.

Figure 1-14 – Single Copper Bypass Unit

NOTE Use the supplied UTP CAT-6 straight Ethernet cables to connect link connections marked with Internal and External labels. The maximum Ethernet cable length is generally 50 meters.

The Single Copper Bypass Unit includes RJ-45 connectors for Ethernet cables and two D-type 9-pin connectors for primary and redundant unit to backup connection.

Page 31: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-19

The following procedure describes how to connect a Single Copper Bypass Unit to NetEnforcer.

Figure 1-15 – Connecting the NetEnforcer AC-802 Copper to the Single Copper Bypass Unit

To connect the Single Copper Bypass to the NetEnforcer:

NOTE For important information regarding cable and connector types, see p. 1-13.

1. Connect the External cable from the External port on the Bypass Unit to the External port on NetEnforcer.

2. Connect the Internal cable from the Internal port on the Bypass Unit, to the Internal port on NetEnforcer.

To External Router

To Internal Switch

Page 32: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-20

3. Connect the D-type connector from the Primary port on the Bypass Unit, to the Backup port on NetEnforcer.

4. Connect the External cable from the External port on the Bypass Unit, to a router connector.

5. Connect the Internal cable from the Internal port on the Bypass Unit, to a switch connector.

NOTES To connect a secondary NetEnforcer for Parallel Redundancy, you need two NetEnforcers and one Bypass Unit.

Internal and external connectors of the redundant NetEnforcer should be connected directly to the network. There is no need to connect via the Bypass Unit.

Single Fiber Bypass Unit The Single Fiber Bypass Unit works in conjunction with NetEnforcer AC-802 Fiber.

There are two different Single Fiber Bypass units, one for Multi Mode connections (SX fiber) and one for Single Mode (LX fiber).

Figure 1-16 –Single Fiber Bypass Unit – Multi Mode

Figure 1-17 –Single Fiber Bypass Unit – Single Mode

Page 33: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-21

NOTE Use 62.5/125μ or 9/125μ fiber optic cables with dual LC connectors (not provided) to connect 1 Gbps ports of the switch and the router.

The Single Fiber Bypass Unit includes either two duplex LC connectors and one built in fiber cables (for Multi Mode connections) or two quad LC connectors (for Single Mode connections), along with two D-type 9-pin connectors for primary and redundant unit to backup connection.

The following procedure describes how to connect a Single Fiber Bypass Unit to NetEnforcer.

Figure 1-18 – Connecting NetEnforcer AC-802 Fiber to Single Fiber Bypass Unit – Multi Mode

To connect the Single Fiber Bypass to NetEnforcer:

NOTE For important information regarding cable and connector types, see p. 1-13.

To Internal Switch

To External Router

Page 34: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-22

1. Connect the fiber cable labeled External from the Bypass Unit, to the External port on NetEnforcer.

2. Connect the fiber cable labeled Internal from the Bypass Unit, to the Internal port on NetEnforcer.

3. Connect the D-type connector from the Primary port on the Bypass Unit, to the Backup port on NetEnforcer.

4. Connect a 62.5/125μ or 9/125μ External fiber optic cable from the External port on the Bypass Unit, to a 1 Gbps router.

5. Connect a 62.5/125μ or 9/125μ Internal fiber optic cable from the Internal port on the Bypass Unit, to a 1 Gbps switch.

NOTES To connect a secondary NetEnforcer for Parallel Redundancy, you need two NetEnforcers and one Bypass Unit.

Internal and external connectors of the redundant NetEnforcer should be connected directly to the network. There is no need to connect via the Bypass Unit.

AC-804 Bypass Unit

Double Copper Bypass Unit The Double Copper Bypass Unit works in conjunction with NetEnforcer AC-804 Copper.

NOTE Use the supplied UTP CAT-6 straight Ethernet cables to connect link connections marked with Internal and External labels. The maximum Ethernet cable length is generally 50 meters.

The Double Copper Bypass Unit includes RJ-45 connectors for Ethernet cables and D-type 9-pin connectors for primary and redundant unit to backup connection.

Page 35: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-23

The following procedure describes how to connect a Double Copper Bypass Unit to NetEnforcer AC-804.

Figure 1-19 – Connecting the NetEnforcer AC-804 to Double Copper Bypass Unit

To connect the Double Copper Bypass to the NetEnforcer:

NOTE For important information regarding cable and connector types, see p. 1-13.

1. Connect the External cable from the To NetEnforcer External port (Link 1) on the Bypass Unit to the External port on the NetEnforcer (Link 1).

2. Connect the Internal cable from the To NetEnforcer Internal port (Link 1) on the Bypass Unit to the Internal port on NetEnforcer (Link 1).

3. Connect the External cable from the External port on the Bypass Unit, to a router (1000Base-T) connector.

To Internal Switch

To External Router

To Internal Switch

To External Router

Page 36: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-24

4. Connect the Internal cable from the Internal port on the Bypass Unit, to a switch connector.

5. Repeats Steps 1 to 4 for Link 2.

6. Connect the D-type High Density connector from the Primary port on the Bypass Unit, to the Backup port on NetEnforcer.

NOTES To connect a secondary NetEnforcer for Parallel Redundancy, you need two NetEnforcers and one Bypass Unit.

Internal and external connectors of the redundant NetEnforcer should be connected directly to the network. There is no need to connect via the Bypass Unit.

Double Fiber Bypass Unit The Double Fiber Bypass Unit works in conjunction with NetEnforcer AC-804 Fiber.

There are two different Double Fiber Bypass units, one for Multi Mode connections (SX fiber) and one for Single Mode (LX fiber).

Figure 1-20 – Double Fiber Bypass Unit - MultiMode

Page 37: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-25

Figure 1-21 – Double Fiber Bypass Unit – Single Mode

NOTE Use 62.5/125μ or 9/125μ fiber optic cables with duplex LC connectors (not provided) to connect 1 Gbps ports of the switch and the router.

The Double Fiber Bypass Unit includes connectors for connecting to Link 1 and Link 2 on the AC-804. The Link Connectors area includes either two duplex LC connectors, and one built in fiber cables (for Multi Mode connections) or two quad LC connectors (for Single Mode connections) for each link. In addition, the Double Fiber Bypass Unit includes two D-type 9-pin connectors for primary and redundant unit to backup connection.

Page 38: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-26

The following procedure describes how to connect a Double Fiber Bypass Unit to NetEnforcer AC-804.

Figure 1-22 – Connecting the NetEnforcer AC-804 to Double Fiber Bypass Unit – Single Mode

To Internal Switch

To External Router

To External Router

To Internal Switch

Page 39: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-27

To connect the Double Fiber Bypass to the NetEnforcer:

NOTE For important information regarding cable and connector types, see p. 1-13.

1. Connect the fiber cable labeled To NetEnforcer External (Link 1) from the Bypass Unit to the External port on the NetEnforcer (Link 1).

2. Connect the fiber cable labeled To NetEnforcer Internal (Link 1) from the Bypass Unit to the Internal port on the NetEnforcer (Link 1).

3. Connect a 62.5/125μ or 9/125μ External fiber optic cable from the External (link 1) port on the Bypass Unit to a 1 Gbps router.

4. Connect a 62.5/125μ or 9/125μ Internal fiber optic cable from the Internal port on the Bypass Unit to a 1 Gbps switch.

5. Repeats Steps 1 to 4 for Link 2.

6. Connect the D-type High Density connector from the Primary port on the Bypass Unit, to the Backup port on the Primary NetEnforcer.

NOTES To connect a secondary NetEnforcer for Parallel Redundancy, you need two NetEnforcers and one Bypass Unit.

Internal and external connectors of the redundant NetEnforcer should be connected directly to the network. There is no need to connect via the Bypass Unit.

AC-808 Bypass Unit

Multi-Port Copper Bypass Unit The Multi-port Copper Bypass Unit works in conjunction with the NetEnforcer AC-808.

Page 40: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-28

Figure 1-23 – Multi-Port Copper Bypass Unit

NOTE Use the supplied UTP CAT-6 straight Ethernet cables to connect link connections marked with Internal and External labels. The maximum Ethernet cable length is generally 50 meters.

The Copper Bypass Unit includes RJ-45 connectors for Ethernet cables and D-type 9-pin connectors for primary and redundant unit to backup connection.

The following procedure describes how to connect the Bypass Unit to NetEnforcer AC-808.

To connect the Bypass Unit to the NetEnforcer AC-808:

NOTE For important information regarding cable and connector types, see p. 1-13.

1. Connect the External cable from the To NetEnforcer External port (Link 1) on the Bypass Unit to the External port on NetEnforcer (Link 1).

2. Connect the Internal cable from the To NetEnforcer Internal port (Link 1) on the Bypass Unit to the Internal port on NetEnforcer (Link 1).

3. Connect the External cable from the External port on the Bypass Unit to a router (100Base-T) connector.

4. Connect the Internal cable from the Internal port on the Bypass Unit, to a switch connector.

5. Repeats Steps 1 to 4 for Link 2 to 4.

6. Connect the D-type High Density connector from the Primary port on the Bypass Unit to the Backup port on NetEnforcer.

Page 41: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-29

NOTE To connect a secondary NetEnforcer for Parallel Redundancy, you need two NetEnforcers and one Bypass Unit.

Internal and external connectors of the redundant NetEnforcer should be connected directly to the network. There is no need to connect via the Bypass Unit.

Multi-Port Fiber Bypass Unit The Multi-Port Fiber Bypass Unit works in conjunction with the NetEnforcer AC-808 Fiber. This unit is used for both Multi Mode (SX fiber) and Single Mode (LX fiber) connections.

Figure 1-24 – Multi-Port Fiber Bypass Unit

NOTE Use 62.5/125μ or 9/125μ fiber optic cables with duplex SC connectors (not provided) to connect 1 Gbps ports of the switch and the router.

The Multi-Port Fiber Bypass Unit includes connectors for connecting to Link 1 through Link 4 on the AC-808. The Link Connectors area includes two quad LC connectors for each link. In addition, the Multi-Port Fiber Bypass Unit includes two D-type 9-pin connectors for primary and redundant unit to backup connection.

The following procedure describes how to connect a Multi-Port Fiber Bypass Unit to the NetEnforcer AC-808.

To connect the Multi-Port Fiber Bypass to the NetEnforcer:

NOTE For important information regarding cable and connector types, see p. 1-13.

Page 42: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-30

1. Connect the fiber cable labeled To NetEnforcer External (Link 1) from the Bypass Unit to the External port on the NetEnforcer (Link 1).

2. Connect the fiber cable labeled To NetEnforcer Internal (Link 1) from the Bypass Unit to the Internal port on the NetEnforcer (Link 1).

3. Connect a 62.5/125μ or 9/125μ External fiber optic cable from the External port on the Bypass Unit to a 1 Gbps router.

4. Connect a 62.5/125μ or 9/125μ Internal fiber optic cable from the Internal port on the Bypass Unit to a 1 Gbps switch.

5. Repeats Steps 1 to 4 for Link 2-4.

6. Connect the D-type High Density connector from the Primary port on the Bypass Unit, to the Backup port on the NetEnforcer.

NOTES To connect a secondary NetEnforcer for Parallel Redundancy, you need two NetEnforcers and one Bypass Unit.

Internal and external connectors of the redundant NetEnforcer should be connected directly to the network. There is no need to connect via the Bypass Unit.

Powering Up Connection to AC Power

Power supply cords are intended to serve as the disconnect device. The user can power down the device only by removing all power cords from the power source or the device itself.

Make sure the wall socket outlet is installed near the equipment and that the socket is easy to access. It is recommended that the wall socket outlet be connected to the building installation protection.

Page 43: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-31

When connecting NetEnforcer to 120 / 240 VAC supply, plug into 10 A service receptacles, type N5/10 or NEMA 5-10R. Ensure that each site has a suitable ground. Ground all metal racks, enclosures, boxes and raceways. The NetEnforcer equipment should be reliably grounded through the power supply cord.

Connection to DC Power CAUTION Use a UL listed 10A circuit breaker between a centralized DC power

system and the NetEnforcer power entry module.

Before performing the following procedure, ensure that power is removed from DC circuit.

Verify that power is off to the DC-input circuit.

Wire the DC-input power supply to the terminal block, ensuring that all wire connections are secure (suggested DC-input wires are 14-AWG copper UL listed conductors:

• Ground wire to the ground connector (you should always connect the ground wire first and disconnect it last).

• -48V wire to the - connector.

• -48V return to the + connector.

Restore power to the DC circuit by turning the circuit breaker on (|). Do not restore power until you are ready to boot the NetEnforcer system.

This unit is intended for RESTRICTED ACCESS LOCATIONS in accordance with NEC (National Electric Code) or the authority having jurisdiction. Power supply cable comprises three sets of 2x142AWG copper wires; use UL-listed cable only.

When connecting NetEnforcer to 48/60 V , use a UL-listed 10A circuit breaker between the centralized DC power system and NetEnforcer power entry module as the disconnect device incorporated in the fixed wiring. The circuit breaker must beclose to the NetEnforcer and easily accessible.

Page 44: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-32

The DC supply source is to be located within the same premises as this equipment. There shall be no switching or disconnecting devices in the grounded circuit conductor between the DC source and the point of connection of the grounding electrode conductor.

CAUTION DC Unit Grounding: Before connecting the product to the power line, make sure that the protective ground terminal of the device is connected to the safety ground conductor of the mains power cord.

The mains plug should only be inserted in a socket outlet provided with a connected safety ground. The protective action must not be negated by use of an extension cord (power cable) without a protective conductor (grounding). Any interruption of the protective (grounding) conductor or disconnection of the protective ground terminal can make the device unsafe to use. Intentional interruption is prohibited.

This equipment has a connection between the earthed conductor of the DC supply circuit and the earthing conductor.

Grounding All NetEnforcer equipment has a connection between the grounded conductor of the DC supply circuit and the grounding conductor.

Connect to a reliably grounded SELV source. Grounding is achieved through connection of the power entry module grounding terminal to one power port of the terminal block by min. No. 14 AWG green/yellow conductor.

This equipment shall be connected directly to the DC supply system grounding electrode conductor or to a bonding jumper from grounding terminal bar or bus to which the DC supply system grounding electrode is connected. When connecting the supply wires to the DC main supply, the earth conductor will be connected first and disconnected last.

This equipment shall be located in the same immediate area (such as, adjacent cabinets or any other equipment that has a connection between the grounded conductor of the same DC supply circuit and the grounding conductor, and also the point of grounding of the DC system. The DC system shall not be grounded elsewhere.

Page 45: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 1: AC-800 Series Hardware

NetEnforcer AC-800 Hardware Guide 1-33

Powering Up Via LCD Panel The following procedure describes how to power up the AC-800 series using the LCD panel.

NOTE NetEnforcer and the Bypass Unit have to be fully plugged and connected before power is turned on. This is to ensure proper and systematic power up.

It is recommended to connect the three power line feeds to separate power sources to have full power redundancy. The three bi-color Power LEDs on the rear of NetEnforcer are lit indicating that the power supply is connected to power and no failure condition exists.

The Power LED on the LCD panel should be lit and the Mode LED on the Bypass Unit is off, indicating that the power is on and NetEnforcer is bypassed.

The display area of the LCD panel indicates the following: Power On.

After a few seconds, the display area of the LCD panel indicates the following: System Loading *.

Once the system has completed loading, the following occurs: • The Active LED on the LCD panel is lit and the Mode LED on the Bypass Unit

is lit, meaning that the NetEnforcer is now connected to the network. • The display area of the LCD panel indicates the default view - the current

bandwidth consumption. For example: Inbound: XXX.X Outbound: YYY.Y

You can now proceed to configure the NetEnforcer, as required.

Page 46: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose
Page 47: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

NetEnforcer AC-800 Hardware Guide 2-1

Chapter 2: Placement in the Network

The NetEnforcer is supplied with 10/100/1000 copper interfaces or fiber Gigabit interfaces. The NetEnforcer is normally placed on the internal side of your access router. The Internal port of the NetEnforcer interfaces with your Local Area Network (LAN) and the External port of the NetEnforcer interfaces with your access router.

When connecting the NetEnforcer to the network, use the proper cable.

NetEnforcer is capable of operating parallel to another NetEnforcer to provide Parallel Redundancy or in Serial Redundancy mode.

To connect the NetEnforcer to your network:

1. Connect the Switches on the Internal side of your network to the Internal connectors on the front panel of the NetEnforcer.

2. Connect the Routers on the External side of your network to the External connectors on the front panel of the NetEnforcer.

3. Connect the power cable and power up the NetEnforcer. • When connecting two NetEnforcers in Redundancy mode, use the special cable

supplied.

NOTE After you connect the cables (and the Active LED is on), the Internal and External Link LEDs on the front panel are on. When traffic is passing through the interface, the Activity LEDs blink.

Page 48: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose
Page 49: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

NetEnforcer AC-800 Hardware Guide 3-1

Chapter 3: Setting Up the NetEnforcer

In order to manage and configure NetEnforcer policies remotely from your Web browser, several basic parameters must be configured on NetEnforcer. You can configure these basic parameters using a terminal connected to NetEnforcer or by using the LCD panel.

Configuring Via a Terminal or Telnet You can use a standard terminal /PC running terminal emulation software connected to the Console port, or Telnet via the internet to configure a NetEnforcer. If you choose to connect via the Console port, most standard windows-based PC systems have a terminal emulation program called HyperTerminal that can be used for this purpose. Configure the terminal to run VT100 terminal emulation with the following parameters:

• Baud rate 19200 • 8 bits • Stop bits 1 • No flow control • No parity

Page 50: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-2

To connect a terminal to the NetEnforcer:

1. Use the supplied serial cable to connect the terminal to the Console Connector on the front panel of the NetEnforcer.

2. Connect the power cable and power up the NetEnforcer, as described in Powering Up, page 1-29.

3. At the terminal, select Start > Programs > Accessories and double-click on the HyperTerminal icon. Enter a name for the session and then to set the com port and the parameters (see above). The system boots up and you are prompted for a login and a password.

4. Enter admin for the login and allot for the password. (To change the password, see page 3-9.)

5. Press <Enter>. The NetEnforcer Setup Menu is displayed:

Figure 3-1 – NetEnforcer Setup Menu

Page 51: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-3

To connect to a NetEnforcer via Telnet:

1. Open a Microsoft DOS window on a PC and at the C:\ prompt, enter Telnet (IP address of NetEnforcer). Press <Enter>. The system boots up and you are prompted for a login and a password.

2. Enter admin for the login and allot for the password. (To change the password, see page 3-9.)

Press <Enter>. The NetEnforcer Setup Menu is displayed:

NetEnforcer Start Menu From this menu, you can perform the following tasks:

• Display the current configuration, page 3-3. • Configure network parameters, page 3-6. • Change the login password, page 3-9. • Modify the date and time settings, page 3-10. • To Reboot or Shutdown the unit, page 3-15.

Displaying the Current Configuration You can display and view the currently set network configuration parameters at any time.

Page 52: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-4

To display the current configuration:

1. In the NetEnforcer Setup Menu, enter 1 (List current configuration) and press <Enter>. The current network configuration parameters are displayed. A sample screen is shown below:

Figure 3-2 – Current Configuration (1)

2. Press <Enter> to show the second screen of parameters:

Page 53: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-5

Figure 3-3 – Current Configuration (2)

3. Press <Enter> to return to the NetEnforcer Setup Menu.

Page 54: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-6

Configuring Network Parameters You can define network parameters manually.

To define network parameters manually:

1. In the NetEnforcer Setup Menu, enter 2 (Network configuration) and press <Enter>. The Network Configuration menu is displayed:

Figure 3-4 – Network Configuration

2. Enter 2 (Manual configuration) and press <Enter>.

Page 55: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-7

3. Enter values for the following IP parameters:

Device IP Address The IP address for your NetEnforcer, for example, 10.1.18.7.

Network mask The network mask for your NetEnforcer, for example, 255.0.0.0.

Device Hostname The host name for your NetEnforcer, for example, Jonny2.

Domain name A domain name for your NetEnforcer, for example, allot.com. Do not provide a leading ‘.’.

Default gateway IP address The IP address of your default gateway, for example, 10.0.0.2. If you do not have a default gateway, enter NONE.

Primary name server IP address

If you have a Domain Name Server (DNS), its IP address. If you do not have a DNS, enter none.

Secondary name server IP address

If you have a second DNS, its IP address. If you do not have a second DNS, enter none.

VLAN ID, or NONE [NONE]

Allows the mgmt port to be connected to a VLAN tagged interface.

CAUTION: Misconfiguring this parameter will result in a loss of connection to the NetEnforcer.

4. Enter the following parameters to set up the Management Port: • The duplex type for the Internal interface. Enter full for full duplex, half for half

duplex or auto for AutoSensing. • If you selected full or half duplex, enter the link speed of the Internal interface,

10M or 100M. Use M for Mbps.

Page 56: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-8

• The duplex type for the External interface. Enter full for full duplex, half for half duplex or auto for AutoSensing.

• If you selected full or half duplex, enter the link speed of the External interface, 10M or 100M. Use M for Mbps.

NOTE If the NetEnforcer unit is being managed via NetXplorer, only the Management Port can be configured on the Ethernet Adapter Settings screen.

5. Press <Enter> to finish and return to the Network Configuration menu.

6. To save your configuration, enter 3 (Save latest settings as current configuration) from the Network Configuration menu. A message is displayed, asking whether you wish to make your changes effective immediately. Enter y or n.

Page 57: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-9

Changing the Passwords You can change the login password for either the Admin user or the Monitor user. The Admin user has access to all NetEnforcer functions, while the Monitor user has read-only access. It is strongly recommended to change the default password (allot). NetEnforcer might enable access from anywhere on the Internet, and should therefore be protected with a unique password.

To change the users’ password:

1. In the NetEnforcer Setup Menu, enter 3 (Change password) and press <Enter>. The Password screen is displayed:

Figure 3-5 – Password

2. Enter 1 or 2 to specify the type of user whose password you want to change and press <Enter>.

3. Enter a new password and press <Enter>. The password must be between 5 and 8 characters. You can use a combination of upper and lower case letters and numbers.

4. Re-enter the password and press <Enter>. If the NetEnforcer detects a simple password, a warning is displayed on the screen.

NOTE The new user name and password will be used in the NetEnforcer Log In window when accessing the NetEnforcer through a browser.

Page 58: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-10

Modifying Date and Time Settings You can modify date and time settings as required. You can set the system time manually, or you can set up the NetEnforcer to receive time checks from an NTP (Network Time Protocol) server, if you have one on your network.

To modify the date and time settings:

1. In the NetEnforcer Setup Menu, enter 4 (Set time) and press <Enter>. The Time Setup screen is displayed:

Figure 3-6 – Time Setup

The current day, date, system time and time zone are displayed at the top of the screen.

2. To change the time zone, perform the following steps: • Enter 1 and press <Enter>. • Enter y and press <Enter>. NetEnforcer displays a list of time zones. • Enter the required time zone and press <Enter>.

3. To change the system time, perform the following steps: • Enter 2 and press <Enter>. • Enter the new date and time in the format DD-MM-YYY -HH-mm. For example,

12-05-2001-11-20 for 12th May 2001, 11:20 am.

Page 59: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-11

• Press <Enter> to set the time.

Changing the Root User Password You can change the root password that provides access to super-user rights.

To change the root password:

1. Use the supplied serial cable to connect the terminal to the Console Connector on the front panel of the NetEnforcer.

2. Set the NetEnforcer power switch, located near the NetEnforcer power cable, to the ON position. The system boots up and on the terminal you are prompted for a login and a password.

3. At the terminal, press <Enter>. The system boots up and you are prompted for a login and a password.

4. Enter root for the login and bagabu for the password, and then press <Enter>.

5. Enter passwd and then press <Enter>.

6. Enter a new password and press <Enter>. The password must be between 5 and 8 characters. You can use a combination of upper and lower case letters and numbers.

7. Re-enter the new password and press <Enter>.

When all necessary parameters are set, NetEnforcer prompts you to reboot. After rebooting is completed, NetEnforcer is ready to be connected and to add Quality of Service in your network.

TIP You can further protect access to the NetEnforcer by limiting the hosts that are allowed to manage the unit.

Page 60: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-12

Configuring Via the LCD Panel All NetEnforcer AC-800 Series models provide an LCD panel from which you can configure basic NetEnforcer parameters without connecting a terminal. This enables quick and easy setting of basic parameters such as the IP address of NetEnforcer.

When not being used to configure the NetEnforcer, the display area in the LCD panel displays its default view, which is the current inbound and outbound bandwidth usage. The units are in Kbps or Mbps with one digit after the point and the display is refreshed every five seconds.

NOTE When you are configuring the NetEnforcer and there is no activity for more than 30 seconds, the display area returns to the default view and any modifications to parameters that were not saved are lost.

The Main Menu The LCD panel provides one main menu from where you can perform the following operations:

• Set the NetEnforcer IP address, page 3-13. • Activate Bypass, page 3-14. • Reboot, shutdown or exit the NetEnforcer, page 3-15.

Getting Started on NetEnforcer In order to start working with the NetEnforcer, press the Power button to turn on NetEnforcer. Once the system has completed loading, the display area of the LCD indicates its default view, the current bandwidth consumption of NetEnforcer. For example: Inbound: XX.XM Outbound: YYY.YM

You can now proceed to configure the NetEnforcer, as required.

Page 61: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-13

NOTE If QoS functionality is not included in your NetEnforcer (not enabled by your activation key), the default view indicates the following: Inbound:- Outbound:-.

Setting the NetEnforcer IP Address Setting the NetEnforcer IP address enables you to specify the IP address, netmask and default gateway for NetEnforcer.

To configure the IP address:

1. With the display area displaying the default view, press the Select button. The Main menu is displayed.

2. Press the down arrow once to display the following: Main menu: 2. Setup IP

3. Press the Select button. The display area indicates the following: 2-1.Set IP:

xxx.xxx.xxx.xxx (the current IP address definitions are displayed)

4. Specify the IP address of the NetEnforcer. Use the up and down arrow buttons to select the required number and the left and right arrow buttons to move between the digits.

5. Press the Enter button. The display area indicates the following: 2-2.Set mask:

xxx.xxx.xxx.xxx (the current netmask definitions are displayed)

6. Specify the netmask of the NetEnforcer. Use the up and down arrow buttons to select the required number and the left and right arrow buttons to move between the digits.

7. Press the Enter button. The display area indicates the following: 2-3 Gateway exists [Yes/No]

Page 62: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-14

Select whether you have a gateway defined in your network. If you select N then you will exit to the next step, skipping step 2-4. If you have a gateway select Y and proceed: 2-4.Gateway:

xxx.xxx.xxx.xxx (the current gateway definitions are displayed)

8. Specify the IP address of the default gateway. Use the up and down arrow buttons to select the required number and the left and right arrow buttons to move between the digits.

9. Press the Enter button. The display area indicates the following: [S]ave/[C]ancel

10. Use the arrow buttons to select whether to save the settings or cancel and press the Enter button. The new IP and gateway settings are applied and after a few moments, the display area displays its default view, the current bandwidth consumption.

The following cases of failure may be indicated:

Failure Display

Netmask Save Fail: MASK saveChk NE IP config

Management NIC Save Fail: Mgmt saveChk NE IP config

Gateway Save Fail: GW saveChk NE IP config

Activating Bypass To send the NetEnforcer into Bypass:

1. With the display area displaying the default view, press the Select button. The Main menu is displayed.

2. Press the down arrow three times to display the following: Main menu: 4. Bypass

Page 63: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-15

3. Press the Select button. If the system is not in Bypass mode, the display area indicates the following: Go into Bypass? [Y]es/[N]o

4. Use the arrow buttons to select whether to enter Bypass mode and press the Enter button. The NetEnforcer switches to Bypass mode and after a few moments, the display area displays its default view, the current bandwidth consumption.

Rebooting, Shutting Down and Exiting the NetEnforcer

You can reboot or shut down the NetEnforcer and exit from LCD configuration as required.

To reboot the NetEnforcer:

1. With the display area displaying the default view, press the Select button. The Main menu is displayed.

2. Press the down arrow four times to display the following: Main menu: 5. Reboot

3. Press the Select button. The display area indicates the following: Reboot? [Y]es/[N]o

4. Use the arrow buttons to select whether to reboot the NetEnforcer and press the Enter button. The NetEnforcer reboots and the display area indicates the following: System

Rebooting * (blinking asterisk)

NOTE This message is also displayed in the display area when the NetEnforcer is rebooted using a terminal.

Page 64: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 3: Setting Up the NetEnforcer

NetEnforcer AC-800 Hardware Guide 3-16

To shutdown the NetEnforcer:

1. With the display area displaying the default view, press the Select button. The Main menu is displayed.

2. Press the down arrow five times to display the following: Main menu: 6. Shutdown

3. Press the Select button. The display area indicates the following: Shutdown? [Y]es/[N]o

4. Use the arrow buttons to select whether to reboot the NetEnforcer and press the Enter button. The NetEnforcer reboots and the display area indicates the following: System

Shutting down * (blinking asterisk) After a few seconds, the display area indicates that the NetEnforcer may be powered off.

NOTE This message is also displayed in the display area when NetEnforcer is shutdown using a terminal.

To return to LCD default view:

1. With the display area displaying the default view, press the Select button. The Main menu is displayed.

2. Press the down arrow six times to display the following: Main menu: 7. Exit

3. Press the Enter or the Select button. The display area displays its default view, the current bandwidth consumption.

Page 65: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

NetEnforcer AC-800 Hardware Guide 4-1

Chapter 4: Redundancy

Enabling Redundancy In order to implement redundancy, it is necessary to configure the network interfaces and enable redundancy in each NetEnforcer involved.

Configuring the AC-802 via the NetEnforcer NOTE The AC-802 cannot support Active Redundancy.

1. Configure the Management Port interface via the LCD on the front panel of the NetEnforcer.

2. Log into the NetEnforcer via the Management Port or Telnet (see page 3-1).

3. Open a console connection to the NetEnforcer and use the following CLI commands:

To set the interfaces:

go config nic

• Options are:

o internal1 MODE:SPEED

o external1 MODE:SPEED

For example: go config nic –internal1 full:100

Page 66: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-2

To set redundancy mode:

go config network -redund_mode

• Options are:

o parallel

o serial

For example: go config network –redund_mode parallel

To toggle redundancy:

go config network –bypass_unit

• Options are:

o enable

o disable

For example: go config network –bypass_unit enable

Page 67: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-3

Configuring the AC-802 via NetXplorer 1. Log into NetXplorer

2. Select the NetEnforcer you wish to configure in the Navigation Pane

3. Right-click the NetEnforcer and select Configuration from the drop down menu. OR Click the Configuration button in the Toolbar.

4. Open the NIC tab and in the Action on Failure field, set INTERNAL1 and EXTERNAL1 to fail paired port.

Figure 4-1 – NIC Tab AC-802 – NetXplorer Configuration

Page 68: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-4

5. Open the Networking tab and set the Redundancy Mode as required to Parallel or Serial.

6. Select the Enable Bypass Unit checkbox.

Figure 4-2 – Networking Tab AC-802 – NetXplorer Configuration

7. Click Save. The system will reboot

After rebooting, you can view the changes from the Configuration tab.

For more information concerning NetEnforcer configuration via NetXplorer, see the NetXplorer Operation Guide.

Page 69: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-5

Configuring the AC-804 via the NetEnforcer 1. Configure the Management Port interface via the LCD on the front panel of

the NetEnforcer.

2. Log into the NetEnforcer via the Management Port or Telnet (see page Error! Bookmark not defined.).

3. Open a console connection to the NetEnforcer and use the following CLI commands:

To set the interfaces:

go config nic

• Options are:

o internal1 MODE:SPEED

o internal2 MODE:SPEED

o external1 MODE:SPEED

o external2 MODE:SPEED

For example: go config nic –internal1 full:100

To set redundancy mode:

go config network -redund_mode

• Options are:

o parallel

o active

Page 70: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-6

o serial

For example: go config network –redund_mode parallel

To toggle redundancy:

go config network –bypass_unit

• Options are:

o enable

o disable

For example: go config network –bypass_unit enable

Configuring the AC-804 via NetXplorer 1. Log into NetXplorer

2. Select the NetEnforcer you wish to configure in the Navigation Pane

3. Right-click the NetEnforcer and select Configuration from the drop down menu. OR Click the Configuration button in the Toolbar.

4. Open the NIC tab and in the Action on Failure field, set INTERNAL1 and EXTERNAL1 to fail paired port.

Page 71: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-7

Figure 4-3 – NIC Tab AC-804 – NetXplorer Configuration

5. Set INTERNAL2 and EXTERNAL2 to No Action in the Action on Failure field.

6. Open the Networking tab and set the Redundancy Mode as required to Parallel, Serial or Active.

7. Select the Enable Bypass Unit checkbox.

Page 72: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-8

Figure 4-4 – Networking Tab AC-804 – NetXplorer Configuration

8. Click Save. The system will reboot

After rebooting, you can view the changes from the Configuration tab.

For more information concerning NetEnforcer configuration via NetXplorer, see the NetXplorer Operation Guide.

Configuring the AC-808 via the NetEnforcer 1. Configure the Management Port interface via the LCD on the front panel of the

NetEnforcer.

2. Log into the NetEnforcer via the Management Port or Telnet (see page Error! Bookmark not defined.).

Page 73: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-9

3. Open a console connection to the NetEnforcer and use the following CLI commands:

To set the interfaces:

go config nic

• Options are:

o internal1 MODE:SPEED

o internal2 MODE:SPEED

o internal3 MODE:SPEED

o internal4 MODE:SPEED

o external1 MODE:SPEED

o external2 MODE:SPEED

o external3 MODE:SPEED

o external4 MODE:SPEED

For example: go config nic –internal1 full:100

To set redundancy mode:

go config network -redund_mode

• Options are:

o parallel

o active

Page 74: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-10

o serial

For example: go config network –redund_mode parallel

To toggle redundancy:

go config network –bypass_unit

• Options are:

o enable

o disable

For example: go config network –bypass_unit enable

Configuring the AC-808 via NetXplorer 1. Log into NetXplorer

2. Select the NetEnforcer you wish to configure in the Navigation Pane.

3. Right-click the NetEnforcer and select Configuration from the drop down menu. OR Click the Configuration button in the Toolbar.

4. Open the NIC tab and in the Action on Failure field, set INTERNAL1, EXTERNAL1, INTERNAL3 and EXTERNAL3 to fail paired port.

Page 75: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-11

Figure 4-5 – NIC Tab AC-808 – NetXplorer Configuration

5. Set INTERNAL2, EXTERNAL2, INTERNAL4 and EXTERNAL4 to No Action in the Action on Failure field.

6. Open the Networking tab and set the Redundancy Mode as required, to Parallel, Serial or Active.

7. Select the Enable Bypass Unit checkbox.

Page 76: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-12

Figure 4-6 – Networking Tab AC-808 – NetXplorer Configuration

8. Click Save. The system will reboot

After rebooting, you can view the changes from the Configuration tab.

For more information concerning NetEnforcer configuration via NetXplorer, see the NetXplorer Operation Guide.

Page 77: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-13

Parallel Redundancy Failure of a network device can be catastrophic, causing network downtime and lost business. The key to designing any mission-critical network is to recognize that these failures can occur, and to design a network that can handle failures and still allow the network to function. In order to do this, it is important to use the most reliable equipment, with redundancy built in to all mission-critical equipment.

A NetEnforcer can operate in parallel to provide Parallel Redundancy. Parallel Redundancy requires two NetEnforcer systems and, where an external Bypass Unit is used, a single Bypass Unit.

The Primary NetEnforcer handles the traffic and the Secondary NetEnforcer is designed to be in Standby mode as long as the Primary NetEnforcer is active. Only if, for any reason, the Primary NetEnforcer is not able to function properly does the Secondary NetEnforcer become active.

Both NetEnforcers receive traffic from the internal network, but only the Primary NetEnforcer is passing the traffic to the external network.

While the Primary NetEnforcer receives and handles traffic coming from the external network, the Secondary External interface is disabled, since the system is in Standby mode. If the Primary NetEnforcer should fail, the Secondary NetEnforcer automatically takes control of the traffic, and enables its External interface.

In Parallel Redundancy mode, the Bypass mode is activated in the event that both the Primary and Secondary NetEnforcers fail.

Page 78: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-14

Status Indicators in Parallel Redundancy Mode When operating in Parallel Redundancy mode, two NetEnforcer units are connected. During operation, the LED indicators on NetEnforcer give various readings. The LEDs relevant to operations in Parallel Redundancy mode are the Standby, Active and Power LEDs on the NetEnforcer LCD panel.

The modes of operation of the indicators are described in the following tables:

Standby LED

Active LED

Power LED

Analysis

Primary Unit

OFF ON ON Primary NetEnforcer is in Active mode.

Secondary Unit

ON OFF ON Secondary NetEnforcer is in Standby mode, ready to take over.

Primary Unit

OFF OFF ON Primary NetEnforcer fails or is now booting.

Secondary Unit

OFF ON ON Secondary NetEnforcer took over and it is in Active mode.

Primary Unit

OFF OFF OFF Primary NetEnforcer is powered OFF.

Secondary Unit

OFF ON ON Secondary NetEnforcer took over and it is in Active mode.

Primary Unit

OFF ON ON Primary NetEnforcer is in Active mode.

Secondary Unit

OFF OFF OFF Secondary NetEnforcer is powered OFF. The only Fail-safe mode available now is Bypass.

Page 79: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-15

Standby LED

Active LED

Power LED

Analysis

Primary Unit

OFF OFF ON Primary NetEnforcer failed or not completed booting.

Secondary Unit

OFF OFF ON Secondary NetEnforcer failed or not completed booting. Bypass is activated (in the primary unit and all traffic is going through Bypass.

Table 4-1 – LED Conditions: AC-800 Series, Parallel Redundancy Mode

Secondary NetEnforcer Activation When two NetEnforcers are connected in Parallel Redundancy mode, the Secondary NetEnforcer will take control and become the active unit under the following conditions:

• Upon a Primary subsystem failure. • During booting of the Primary NetEnforcer platform. When booting is

completed, the Primary unit automatically takes control again. • Upon any Primary NetEnforcer power feed failure and power OFF condition. • Upon the Primary NetEnforcer Ethernet cable disconnecting from either the

Internal or External ports. After reconnecting the cable and rebooting, the Primary NetEnforcer takes control again.

• When the Bypass Unit is not connected properly to the NetEnforcer Backup connector, even with all other connectors fully plugged.

NOTE If a cable is disconnected, it is recommended to reboot the Primary NetEnforcer after reconnecting the cable.

Page 80: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-16

To connect two AC-800 Series NetEnforcers in Parallel Redundancy:

Before using NetEnforcers in Parallel Redundancy mode, make sure that the configuration of both NetEnforcers is identical; except for their IP addresses, which must be unique for each unit. You can use the Save & Distribute option to distribute the same QoS policy to both NetEnforcers.

NOTE You can distribute policy to other NetEnforcers, only if they are of the same model as the one from which you are distributing.

After ensuring identical configuration, test each NetEnforcer (while connected to the network as a single device) and verify that they are operating identically to one another.

1. Configure redundancy in both NetEnforcers as outlined in Enabling Redundancy on p.4-1.

2. Designate one of your NetEnforcers to be the default Primary, and connect the end of the Backup cable to the Backup connector of the NetEnforcer.

3. Connect the other end of the backup cable to the Primary connector of the Bypass Unit.

4. Designate the other NetEnforcer to be the Secondary and connect one end of the Backup cable to the Backup connector of the Secondary NetEnforcer.

5. Connect the other end of the Backup cable to the Secondary connector of the Bypass Unit.

6. Ensure that the status indicators of both systems are indicating that the systems are configured correctly, as follows:

• The Active LED of the Primary NetEnforcer is ON. • The Standby LED of the Primary NetEnforcer is OFF. • The Active LED of the Secondary NetEnforcer is OFF. • The Standby LED of the Secondary NetEnforcer is ON.

Page 81: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-17

CAUTION When two NetEnforcers are connected in Parallel Redundancy mode with a switch on each interface, if the Primary NetEnforcer fails and the Secondary system takes control of traffic, the redundant unit may take some time to activate. This is normal switch behavior. The switch will continue to redirect packets to the Primary NetEnforcer, instead of to the Secondary NetEnforcer.

Active Redundancy NOTE Active Redundancy is only relevant to AC-804 and AC-808 units. The AC-

802 cannot support Active Redundancy.

In the Active Redundancy configuration, each NetEnforcer manages a single link while duplicating the link’s traffic to the other NetEnforcer. Both NetEnforcers are active. Each unit shapes the traffic of one link only, but the shaping algorithm considers traffic of both links. Such configuration is recommended for network topologies where both links are active in load-balancing mode.

Failover In the event that one of the links fails due to router, switch or line malfunction, the network redundancy mechanism (for example, spanning tree) will ensure that traffic is routed or switched via the other link and managed by the second NetEnforcer. Since both NetEnforcers maintain a constant view of the two links, there will be no loss of flow's state and other information required for correct shaping and application classification. Note that the bypass function is not used in such configurations.

Policy Configuration In the Active Redundancy configuration, the two NetEnforcers should share the same policy configuration.

Page 82: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-18

Connecting the NetEnforcer in Active Redundancy Line 1 (and 3 in the AC-808) is used to pass actual traffic – these interfaces will be used to connect the NetEnforcers to the corresponding switches or routers.

Line 2 (and 4 in the AC-808) is used to duplicate traffic and pass it to the second NetEnforcer. Traffic that is passed between NetEnforcers is not sent to adjacent network devices – it is only used for monitoring and classification purposes.

Active Redundancy for the AC-804 In this configuration the operator uses two links to access the Internet. To achieve redundancy, each link will use a separate switch and router. Each link requires an AC-804 unit and a bypass unit to enable Active Redundancy.

Figure 4-7 – Active redundancy using AC-804

Page 83: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-19

Each link has a similar structure. The switch port is connected to the Internal port of the first line card’s bypass unit. The corresponding port is connected to the Internal port of the AC-804. The External port of the AC-804 is connected to the external port of the bypass unit while its corresponding port connects to the router. The other ports of the bypass unit remain unconnected. The two AC-804 cross-connect one to another with two links to enable synchronization of traffic between the two units.

Active Redundancy for the AC-808 This configuration is suitable for a high-availability fully meshed environment, where operators use two switches and two routers to connect their networks to the Internet. Each switch connects to the two routers to provide redundancy.

In this scenario, two AC-808 units are installed together with two bypass units. The connectivity among the different network elements is shown in Figure 4-8.

Figure 4-8 – Active Redundancy using AC-808

Page 84: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-20

• The two AC-808 units cross-connect one to another with four links to synchronize the traffic information between themselves.

• Each AC-808 unit connects via its corresponding bypass unit to the two switches (via two internal interfaces) and to a router (via two external interfaces).

• The remaining interfaces of the bypass units remain unconnected.

Page 85: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-21

Serial Redundancy In Serial Redundancy two bypass units are connected to the network in serial and the two NetEnforcers work in Active/Bypass mode.

NOTE In Serial Redundancy mode the two bypass units are connected to each other via a DB-9 cable (P/N C411012) available separately from Allot. This cable is labeled as the Serial Redundancy cable with its PN number and should NOT be confused with the Parallel Redundancy cable. They are NOT interchangeable. The Serial Redundancy cable connects to the Primary port of one unit and the Secondary port of the other.

One probe is in active mode at all times, and the other is in bypass mode. There is no probe is standby mode. When the active probe moves to bypass, the passive probe switches to active.

Even if the previously active probe recovers, it will remain in bypass. The system will not try to converge to a pre-determined configuration, as it does in parallel redundancy

In a normal situation the Primary Bypass forwards all traffic to the Primary NetEnforcer’s which is in Active mode.

Figure 4-9 – Serial Redundancy – Normal Scenario

Page 86: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-22

NetEnforcer Failover In case the Primary NetEnforcer fails, it will go in to bypass mode forwarding all traffic directly to the network bypassing the failed NetEnforcer. The Secondary NetEnforcer will go into active mode forwarding all traffic via the secondary unit. NetEnforcer functionality will be maintained.

In the unlikely situation where the Secondary unit fails, it will go in to bypass mode bypassing the failed NetEnforcer. Network connectivity will maintain but all NetEnforcer functionality will be lost.

Bypass unit is provided with each NetEnforcer units. In case of failover situation (including power-loss), the links connected to the bypass will be wired (cross connected) and traffic will not be disturbed. The bypass unit is a passive device and does not require external power supply.

Figure 4-10 – Serial Redundancy – Failover Scenario

Page 87: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-23

Figure 4-11 – Serial Redundancy – Bypass Scenario

Serial Redundancy in Mesh Topologies Serial Redundancy can support mesh topology configurations. In the network diagram described below, each of the NetEnforcer units should be able to handle two links which requires it to have four network interfaces. The AC-804 can be used in such a configuration.

Page 88: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 4: Redundancy

NetEnforcer AC-800 Hardware Guide 4-24

Figure 4-12 – Serial Redundancy – Mesh Scenario

In a network configuration with four network interfaces, each of the NetEnforcer units must have eight network interfaces. The AC-808 can be used in such a configuration.

Page 89: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

NetEnforcer AC-800 Hardware Guide 5-1

Chapter 5: Hardware Specifications

Dimensions Standard 2U by 19-inch, rack mountable

Height 3.46 in (88 mm)

Width 17.32 in (440 mm)

Depth 14.76 in (375 mm)

Weight Copper: 24.9 lbs (11.3 kg) Fiber: 25.3 lbs (11.48 kg)

NOTE The weight of the Copper Bypass Unit is 3.86 lbs (1.75 kg) and the weight of the Fiber Bypass Unit is 4.28 lbs (1.94 kg).

Power Requirements

AC Power Input Voltage 100 - 240 V

Frequency 50/60 Hz

Current 9 - 5 A

DC Power Input Voltage 48 - 60 V

Current 12 - 6 A

Page 90: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 5: Hardware Specifications

NetEnforcer AC-800 Hardware Guide 5-2

Operating Environment Temperature 32° F to 104° F (0° to 40° C)

Humidity 5% to 95% (non condensing)

Standards, Compliance and Certifications All AC-800 models hold certificates for and comply with the standards listed below.

EMC • EMC Directive 89/336/EEC, article 7(1) • EN 55022:1998+A1(00) class A • EN 61000-3-2:1995_A1(98)+A2(98) • EN 61000-3-3:1995 • EN 55024:1998+A1(01) • FCC 47 CFR part 15, subpart B, class A • ICES-003:1997, class A • VCCI:2002, class B • NEBS: GR-1089-Core*

Safety • IEC 60950:1999 with Japanese deviations • EN 60950:2000 • NEBS: GR-1089-Core*

UL • 1950 NetEnforcer UL File number: E206586 • CAN/CSA C22.2 No.60950-00 * UL 60950, third edition

Page 91: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 5: Hardware Specifications

NetEnforcer AC-800 Hardware Guide 5-3

Environmental • ETS 300 019-2-2 T 2.1 • ETS 300 019-2-3 T 3.1 • NEBS: GR-63-Core*

*NetEnforcer is designed to meet these standards.

Page 92: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose
Page 93: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

NetEnforcer AC-800 Hardware Guide 6-1

Chapter 6: Firewall Port Reference

Basic Management If your NetEnforcer using Basic Management is working behind a firewall, the following ports must be opened on the firewall to enable access to the NetEnforcer management functions:

Firewall Port Gives Access To

TCP Port: 23 Telnet

TCP Port: 80 Web Server/GUI

TCP Port: 56000 Internal Accounting GUI Access

TCP Port: 51000 Policy Editor GUI Access

TCP Port: 52000 Monitoring GUI Access

TCP Port: 53000 Alerts GUI Access

TCP Port: 53306 MySQL Access

TCP Port: 56000 External Accounting Data Transfer Access

Page 94: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 6: Firewall Port Reference

NetEnforcer AC-800 Hardware Guide 6-2

NetXplorer In some networks, the NetEnforcer can be separated from the NetXplorer server by a firewall for security reasons.

To enable the communication between the NetXplorer and NetEnforcers the following ports in the Firewall should be opened:

• TCP/80 HTTP

• UDP/161 SNMP

• UDP/162 SNMP Trap

• UDP/123 NTP

• TCP/123 NTP

Page 95: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

NetEnforcer AC-800 Hardware Guide 7-1

Chapter 7: Équipement de série AC-800

Le NetEnforcer est une passerelle d’apprentissage transparente certifiée conforme à la norme IEEE 802.1, fonctionnant parallèlement à une unité de dérivation en vue d’assurer la continuité du débit de données en cas de problème matériel ou logiciel. La dérivation du NetEnforcer redirige l’ensemble du trafic uniquement vers des éléments passifs, permettant ainsi au réseau de fonctionner.

Le NetEnforcer de série AC-800 associe une conception de fournisseur de service à une redondance des éléments fondamentaux afin de garantir la continuité du fonctionnement du système en cas de panne.

Les mises en garde et remarques suivantes doivent faire l’objet d’une attention toute particulière :

Mises en garde d’ordre général

CONFIGURATION Afin de garantir une continuité de service en cas de panne, l’ensemble des modèles de la série AC-800 fonctionne uniquement en raccordement avec une unité de dérivation adaptée.

LASER PRODUIT LASER DE CLASSE 1. DANGER !

Rayonnement laser invisible en cas d’ouverture.

ÉVITER TOUTE EXPOSITION DIRECTE AU FAISCEAU.

ALIMENTATION Avant de retirer le couvercle, déconnecter le produit de l’alimentation secteur. Toute opération de réglage et d’entretien réalisée au niveau du dispositif doit uniquement être effectuée par un personnel qualifiée, avec l’appareil déconnecté de sa source d’alimentation.

Page 96: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 7: Équipement de série AC-800

NetEnforcer AC-800 Hardware Guide 7-2

ALIMENTATION C.C.

La source d’alimentation c.c. doit être protégée contre les surintensités par un circuit de dérivation affichant une intensité nominale de 10 A, basé dans le bâtiment et capable de déconnecter simultanément les deux pôles.

CÂBLE D’ALIMENTATION C.C.

Mise à la masse de l’unité c.c. : Avant de raccorder le produit à une ligne d’alimentation, s’assurer que la borne de masse de protection du dispositif est reliée au conducteur de masse de sécurité du cordon d’alimentation secteur.

La prise mâle secteur doit uniquement être insérée dans une prise femelle connectée à la masse. Cette mesure de protection ne doit pas être contrecarrée par l’utilisation d’une rallonge non munie d’un conducteur de protection (relié à la masse).

Toute interruption du conducteur de protection (relié à la masse) ou toute déconnection de la borne de masse de protection pourrait compromettre la sécurité du dispositif. Toute interruption volontaire est strictement interdite.

Dans cette gamme d’appareils, le conducteur relié à la masse du circuit d’alimentation c.c. est raccordé au conducteur de masse.

DÉRIVATION Afin de garantir la continuité du service en cas de panne, toute unité NetEnforcer AC-800 doit être reliée à une unité de dérivation adaptée.

Redondance Dans le cas d’une connexion en mode redondant de deux dispositifs NetEnforcers à un commutateur sur chaque interface, l’unité redondante pourrait mettre un certain temps à reprendre le contrôle du trafic si le dispositif primaire venait à présenter une défaillance et que le dispositif secondaire prenait le contrôle du trafic. Il s’agit-là d’un comportement tout à fait normal de la part du commutateur, qui continuera à rediriger les paquets de données vers le distributeur primaire, plutôt que vers le dispositif NetEnforcer secondaire.

Page 97: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 7: Équipement de série AC-800

NetEnforcer AC-800 Hardware Guide 7-3

Remarques d’ordre général LASER Dans le cas d’un produit doté d’un émetteur-récepteur en fibre optique, les

émissions dégagées par les produits décrits dans ce guide sont de Catégorie 1, conformément aux normes IEC 60825-1 et FDA 21 CFR 1040.10 / 1040.1. Ces produits ne doivent en aucun cas être installés dans un réseau optique traitant des émissions de classe supérieure à 1.

Paramétrage Il est déconseillé de modifier les paramètres par défaut du NetEnforcer ; la modification des paramètres NIC s’effectue uniquement par le biais du panneau ACL.

L’alimentation c.a. s’adapte automatiquement à des tensions comprises entre 100 et 240 V, à une fréquence de 50/60 Hz. L’alimentation c.c., quant à elle, s’adapte automatiquement à des tensions de 48 ou 60 V c.c.

Cet équipement est destiné à une utilisation dans un espace à accès limité et par un personnel dûment qualifié. Pour éviter tout choc électrique, ne réaliser aucune opération autre que celles décrites dans le feuillet d’instructions de déballage.

Alimentation Pour supprimer un module d’alimentation, soulever la poignée inférieure et extraire le module.

Alimentation Le AC-800 comprend trois modules d’alimentation afin de permettre une redondance, deux modules fonctionnant sont le minimum requis pour permettre la continuité de son alimentation dans le cas d’une défaillance.

Câbles

Ethernet en cuivre

À l’aide des câbles Ethernet droits UTP CAT-6 fournis, raccorder les connexions de lien portant les étiquettes Internal (Interne) et External (Externe). La longueur maximale de ces câbles est généralement de 50 mètres.

Câbles

Ethernet en fibre optique

À l’aide de câbles en fibre optique de 62.5/125μ ou 9/125μ dotés de connecteurs LC doubles (non fournis), raccorder les ports 1 Gbps du commutateur au routeur.

Page 98: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 7: Équipement de série AC-800

NetEnforcer AC-800 Hardware Guide 7-4

Spécifications matérielles Dimensions Conception 2U standard de 19 pouces, montable en rack

Hauteur 88 mm (3.46 in.)

Largeur 440 mm (17.32 in.)

Profondeur 375 mm (14.76 in.)

Poids Cuivre: 11,3 kg (24.9 lbs)

Fibre optique: 11,48 kg (25.3 lbs)

REMARQUE L’unité de dérivation en cuivre pèse 1,75 kg (3.86 lbs) ; celle en fibre optique pèse 1,94 kg (4.28 lbs).

Spécifications requises Alimentation Tension c.a. en entrée 100 - 240 V

Fréquence 50/60 Hz

Intensité 9 – 5 A

Tension c.c. en entrée 36 - 72 V

Intensité 12 - 6 A

Conditions ambiantes Température 0 à 40 °C (32 à 104° F)

Humidité 5 à 95 % (sans condensation)

Page 99: NetEnforcer - intelek.eu · NetXplorer Centralized Management software can be purchased for any AC-800 series device, replacing the basic management. The NetEnforcer AC-802 is a general-purpose

Chapter 7: Équipement de série AC-800

NetEnforcer AC-800 Hardware Guide 7-5