New ADAP-KOOL®AK-CT 200
www.danfoss.com
OneHardwarefor over 300 tray variants
Danfoss Food Retail February 2014 | 2
Fully Integrated gear tray and case controller
Today’s power tray solution
Standard electromechanical components and electrical wiring
New ADAP-KOOL® AK-CT 200
Integrated power components
Current measurements
Zero-crossing technology
Pluggable spring loaded wire connectors
Create variants by different selection of electrical components and wiring:
Large number of customized trays
Different electromechanical fuse sizes
Many different blueprints
Different power trays for 1 and 3 phase
Create variants by software configuration:
1 version with software configuration of relays and application “soft wiring”
Configurable fuse size (0->16 Amp)
One common label for all display cases
Power management from 10 Watt to 10 KW
Danfoss Food Retail February 2014 | 3
Existing solution @ Norpe - 300 different variants
Service switch
Case Controller
Wiring diagram / documentation
300 different blue prints
Internal Wirings
Fuses
Contactors
Connectors for external wires
Danfoss Food Retail February 2014 | 4
Reduced complexity withnew Integrated Controller Tray
Reduced complexity
Fewer variants
Lower risk of wiring mistakes
Quick configuration
Improved service features
Easy check of I/O’s
Easy food type setup
Improved monitoring
Easier remote analysis
Extended information for data analysis
Fast reaction time from alarm to service
First time fix
Reliable
Robust against electromagnetic interference (EMC)
Zero crossing relays
Static cooling
Easy controller service
One fits all
Danfoss Food Retail February 2014 | 5
AK-CT 200 providing benefitsthroughout the value chain
OEM production
More than 300 variants with one hardware
Simplified handling of gear trays
Less wiring mistakes
OEM productionIn store
commissioningOnsite service
Remote monitoring
In store commissioning
Easy I/O check
Time saving with “Quick Configuration”
Communication status for fast fault finding
Onsite service
Easy change of food type
Easy I/O check
Reduced time for trouble shooting
Remote monitoring
Remote current monitoring
Remote fuse information and reset
Door openings
Root cause alarms
First time fix
Danfoss Food Retail February 2014 | 6
Controller key for late dedication
Control function can be defined at the end of production line.
Only one tray version for more than 300 different cabinets.
AK-CT201
Enable controller tray to be used with 3’rd party controller
AK-CT 450
Enable controller to control display case with TXV
AK-CT550
Enable controller to control display cases with AKV
Common features for all 3 versions
Manual override of light via pushbutton (DI)
Stop of fans while blinds down
Fan ECO - Reduced speed while blinds down
High power control of more than 300 different display cases
Danfoss Food Retail February 2014 | 7
3d party control
Danfoss Food Retail February 2014 | 8
EVR
Danfoss Food Retail February 2014 | 9
AKV
Danfoss Food Retail February 2014 | 10
Application selection from param. o61
Danfoss Food Retail February 2014 | 11
Zero cross relay control vs. traditional contactors
Traditional contactor
Mechanical life time ?
No control of Cut in or Cut out of loads -> high tear and weariness
High power PCB relay with Danfoss Zero crossing technology
High mechanical lifetime
Long lifetime on contacts due to limited (no) spark at cut in or cut out of loads
Sparks
Cut In Cut Out
Voltage = 0 Amp = 0
Danfoss Food Retail February 2014 | 12
Current measurement & alarms
MAX – MIN alarm!
Danfoss Food Retail February 2014 | 13
Programming can be done in different ways
Via Modbus with own production and test software
Via Danfoss AK-SM 720 and AK-ST 500
Via OEM programming key + PC with USB connection and Microsoft Excel
Danfoss Food Retail February 2014 | 14
Danfoss Food Retail February 2014 | 15
ID-key copy
- Parameters are stored in the ID-key + AK-CT 200A.
- AK-CT will work for 2 weeks without a ID-key
- network address (o03) is also copied
Danfoss Food Retail February 2014 | 16
How do I reset a “software fuse” ?
√ Fuse alarms can be seen in AKA 164 display
√ E41 = Fuse alarm on DO1
√ E42 = Fuse alarm on DO2
√ E48 = Fuse alarm on DO8
√ Flashing red Fuse LED indicate fuse alarm on one or more of the relays DO1 -> DO8
√ Fuses can be reset in 3 different ways:
1. Power Off and On via circuit breaker will restart the controller and reset fuses
2. Fuse can be reset in Service menu for output status when FuS is shown for do1 -> do8 by setting output to on
3. Fuse can be reset in configuration menu by parameter L21 to L28 set to on from AKA display or remote by setting to 1
Danfoss Food Retail February 2014 | 17
New controller tray – accessories
Extra connectors for multi wires
If more than 3 cable connectors are needed
Optional AKA 164 display
Can be mounted in controller tray or in display case
Controller key for late dedication
AK-CT 201, CT 450, CT550
Controller functions and copy of settings
Danfoss Food Retail February 2014 | 18
Space for optional display
Accessories
Prepared for optional connector
Danfoss Food Retail February 2014 | 19
System Manager compatibility
-SM 720 ver.2.73 OK
-SM350 ver.1.70 OK, but no template yet!
-SM800 ver.8.027 OK.
-AKA 24x (LON) partly:
missing param. with AK-CT550A:
Danfoss Food Retail February 2014 | 20
- Appliance shut-down function (=external main switch, but no stand by alarm)
- Modbus communication status, 0/100% = everything ok, (U45)
- Pe & AKV connector identical, careful when replacing controller!
- Not used fuses; 16A by default, set to 0A
- EEC coil not supported
- HACCP approved, CE & other electrical approvals available
- Measurement of insulation resistance @ 500V. Loads must be manually wired (can’t push manually contactors like normally)
- No Danbuss option
- EKA 183A copy key support coming from next version (sw. 1.32)
- Integrated 24h real time clock
- ECO function for evap. fans (cut fan speed when night blind down)
- 2-light relays (spot lights)
- Controller & AKV powered from L1 (1-phase)
- 0…10V output for valve OD (AO1)
Other info
Danfoss Food Retail February 2014 | 21
Room application
- Need 2,5 mm2 cabling, also AKV. (Check with local authorities!)
- When door function is open it signals that the door is open, usually motion detectors are ”NO” (DI7), needs extra relay
- Residual-current circuit breaker (30mA) needed for rooms
(personal safety, rail/drip tray heat)
- Only for 1-phase evaporator fan
Danfoss Food Retail February 2014 | 22
Instruct electricians to check for missing neutral!
- Normally this is not part of electrical installation inspection!