The legends live on – as cool as you like!Centrifuge 5415 R and Centrifuge 5417 R

Centrifuge 5415 R5417 R

2

Refrigerated centrifugation – Eppendorf is the solution

Centrifuge 5415 R

The refrigerated 24-place Centrifuge 5415 R: A convincing combination of matchless quality and the experience of the no. 1 worldwide provider of refrigerated microcentrifuges. Top-class made by Eppendorf.

The Centrifuge 5415 R offers the unmistakable ease-of-use of an Eppendorf product. With the familiar dials enabling quick and easy setting of speed and time.

The extremely smooth running motor prevents unnecessary vibrations after the centrifuge process.The optional aerosol-tight rotor allows an even broader range of applications.

The Eppendorf Centrifuge 5415R – the centrifuge of the future – even today!

Product features of the Centrifuge 5415 R

‡ Turning knobs and digital display‡ Easy switching between rpm and rcf – eliminating tedious

calculations‡ Separate Short Spin key for convenient quick spins‡ Max. rcf: 16,100 × g‡ Very low access height‡ 24-place standard rotor for 1.5/2 ml tubes (adapter for 0.2 ml,

0.4 ml, 0.5 ml and 0.6 ml tubes), autoclavable; also available with aerosol-tight lid**

‡ 36-place special rotor for 0.5 ml tubes (adapter for 0.2 ml tubes)‡ Temperature settings from 0 – 40 °C‡ Sample temperature of 4 °C maintained at maximum speed‡ Standby cooling‡ Motorized lid latch

For further information, please visit www.eppendorf.com/5415R

* Eppendorf centrifuges are designed for separating substance mixtures with different densities, especially for processing and analyzing samples from the human body in an in vitro diagnostic application, in order to enable the use of the in vitro diagnostic device in accordance with its in-tended purpose. Therefore, centrifuges used as in vitro diagnostic accessories are themselves in vitro diagnostic devices according to Directive 98/79/EC of the European Parliament and the Council dated October 27, 1998 on in vitro diagnostic medical devices.Eppendorf centrifuges are intended exclusively for use indoors, and for operation by qualifi ed staff.

** Lid tested for aerosol-tightness by the Centre for Applied Microbiology & Research, Porton Down.

*** The polymerase chain reaction (PCR) is proprietary to Hoffmann-La Roche.

3

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

PCR strip rotor

‡ Max. speed 10,000 rpm (max. rcf: 10,600 × g) ‡ Up to 6 × 8-tube strips, 6 × 5-tube strips or 48 indi-vidual 0.2 ml PCR tubes

The refrigerated 30-place Centrifuge 5417 R requires a minimum of bench space and offers you a very low access height. The clear display and the convenient keypad guarantee easy and intuitiv operation. With short acceleration and braking times at max. rcf, and its high capacity, the Centrifuge 5417 R manages even high sample throughputs with fl ying colors. The standby cooling, keeps the centrifuge at the required temperature after the centrifuge run.

Centrifuge 5417 R

Product features of the Centrifuge 5417 R

‡ Small footprint – low access height‡ Easy switching between rpm and rcf – eliminating tedious

calculations‡ Separate Short Spin key with adjustable speed for quick spins‡ Smooth start/stop function to protect sensitive samples‡ Accommodating suitable up to fi ve rotors, such as

24-place high-speed rotor PCR strip rotor***6 × 8 PCR strips

‡ Automatic rotor detection system with speed limitation

Swing-bucket rotor

‡ 8 places for 1.5/2 ml micro test tubes‡ Max. speed: 10,000 rpm (max. rcf: 10,600 × g)‡ For pellet formation at the bottom

of the tube when working with small samples

Fixed-angle rotors

‡ Adapters available for 0.2 ml PCR tubes and 0.4 ml centrifuge tubes as well as 0.5 ml micro test tubes and 0.6 ml Microtainers®

‡ Max. rcf/max. speed: 25,000 × g/16,400 rpm‡ Rotors, rotor lids and adapters are autoclavable

(20 min, 121 °C); the FA-45-24-11 and FA-45-30-11 rotors with lid can even be autoclaved for 2 hours at 140 °C in order to eliminate prion contamination

For further information, please visit www.eppendorf.com/5417R

Your local distributor: www.eppendorf.com/worldwideEppendorf AG · 22331 Hamburg · Germany · Tel: +49 40 538 01-0 · Fax: +49 40 538 01-556 · E-mail: [email protected]

Eppendorf North America, Inc. · One Cantiague Road · P. O. Box 1019 · Westbury, N.Y. 11590-0207 · USATel: +1 516 334 7500 · Toll free phone: +1 800 645 3050 · Fax: +1 516 334 7506 · E-mail: [email protected]

Application Support Europe, International: Tel: +49 1803 666 789 · E-mail: [email protected] America: Tel: +1 800 645 3050 ext. 2258 · E-mail: [email protected]

Asia Pacific: Tel: +60 3 8023 6869 · E-mail: [email protected]

epp

endo

rf® is

a r

egis

tere

d tr

adem

ark

of E

pp

endo

rf A

G. A

ll rig

hts

rese

rved

, inc

ludi

ng g

rap

hics

and

imag

es. C

opyr

ight

© 2

009

by E

pp

endo

rf A

G.

Ord

er N

o. Q

07 8

39 0

20/3

T/08

09/F

EE

L/S

TEF

· Prin

ted

in G

erm

any

Centrifuges 5415 R and 5417 R

Ordering Information

Description Max. rcf (× g) Max. speed (rpm) Order No.

Centrifuge 5415 R

230 V/50–60 Hz, without rotor 5426 000.018

F-45-24-11 fixed-angle rotor, for 24 x 1.5/2.0 ml micro test tubes incl. lid (polypropylene)

16,100

13,200

5425 725.000

Rotor lid (polypropylene) for rotor F-45-24-11 5425 701.004

FA-45-24-11 fixed-angle rotor, for 24 × 1.5 ml/2.0 ml micro test tubes, aerosol-tight rotor, incl. lid (metal)

16,100

13,200

5425 737.009

F-45-36-6 fixed-angle rotor, 36 × 0.5 ml fixed-angle rotor, incl. lid (polypropylene) 16,100 13,200 5425 730.004

Adapter for 0.2 ml PCR tubes, for use in rotor F-45-36-8, set of 6 5425 723.008

Centrifuge 5417 R

230 V/50–60 Hz, without rotor 5407 000.317

F-45-30-11 fixed-angle rotor 30 × 1.5/2 ml, incl. aluminum lid 20,800 14,000 5490 015.002

FA-45-30-11 fixed-angle rotor 30 × 1.5/2 ml, incl. aluminum lid, aerosol-tight* 20,800 14,000 5490 025.008

FA-45-24-11 fixed-angle rotor 24 × 1.5/2.0 ml, incl. aluminum lid, aerosol-tight* 25,000 16,400 5490 061.004

A-8-11 swing-bucket rotor 8 × 1.5/2 ml, incl. aluminum lid 10,600 10,000 5492 008.003

F-45-48-PCR fixed-angle rotor for 6 × 8 PCR strips, 6 × 5 PCR strips or 48 individual 0.2 ml PCR tubes

10,600

10,000

5490 060.008

Adapter for all fixed-angle rotors for inserting PCR and micro test tubes (set of 6)

for 0.2 ml PCR tubes, adapter bore Ø 6 mm for 0.4 ml micro test tubes, adapter bore Ø 6 mm for 0.5 ml micro test tubes and 0.6 ml Microtainers®, adapter bore Ø 8 mm

5425 715.005 5425 717.008 5425 716.001

Technical specifications

Description Centrifuge 5415 R Centrifuge 5417 R

Max. rcf 16,100 × g 25,000 × g

Max. rotational speed 13,200 1/min 16,400 1/min

Acceleration time to max. speed ≤13 s ≤13 s

Braking time from max. speed ≤11 s ≤11 s

Timer 30 s to 99 min, with continuous run function 30 s to 99 min, with continuous run function

Temperature setting range 0 to 40 °C –9 to 40 °C

Weight excl. rotor 21.2 kg 35 kg

Dimensions (W × D × H) 29 × 45 × 25 cm 31 × 60 × 25 cm

Technical specifications subject to change.

* Aerosol-tightness has been tested and approved in accordance with the procedure of Bennett et al. from the Centre for Applied Microbiology & Research in Porton Down, CAMR, Great Britain, and in accordance with annex AA of the IEC 1010-2-020 safety standard. The test procedure simulates the accidental release of biological material (bacteria) inside the closed rotor or closed rectangular bucket. Air and swab samples are taken to ensure that no material is released from the closed rectangular buckets or closed rotor during operation.

® Registered trademark of Becton Dickinson.