new gen incinerator atlas

8
7/30/2019 New Gen Incinerator Atlas http://slidepdf.com/reader/full/new-gen-incinerator-atlas 1/8    N   e   w     G   e   n   e   r   a    t    i   o   n INCINERATORS

Upload: andrei-stocker

Post on 04-Apr-2018

277 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: New Gen Incinerator Atlas

7/30/2019 New Gen Incinerator Atlas

http://slidepdf.com/reader/full/new-gen-incinerator-atlas 1/8

   N

  e  w    G  e

  n  e  r  a   t   i  o  n

INCINERATORS

Page 2: New Gen Incinerator Atlas

7/30/2019 New Gen Incinerator Atlas

http://slidepdf.com/reader/full/new-gen-incinerator-atlas 2/8

INCINERATORS

 ATLASINCINERATORSfor simultaneousburning of OILSLUDGE andSOLID WASTE

The Atlas Incinerator three

chamber design is one ofmany reasons that Atlas

Incinerators meet theconstruction regulations

and tough emission rules

issued by IMO. (TheInternational Maritime

Organisation)

Extra combustion air is

injected into the afterburning chambers, ignitingand thereby ensuring

destruction of all unburned

particles. This extra flowprocess prevents not only

unburned particles, but also

flames from escaping theincinerator and entering the

chimney.

All chambers are protected

by high temperature

castable lining backed upby fibre insulation.

3 CHAMBER

DESIGN

Page 3: New Gen Incinerator Atlas

7/30/2019 New Gen Incinerator Atlas

http://slidepdf.com/reader/full/new-gen-incinerator-atlas 3/8

INCINERATORS

Exhaust Draft

Flue gas fans are typical trouble spots, and Atlas Incinerators’

unique air-flow system is one of many reasons that our incinerators

require minimal maintenance and repair. The incinerator is afactory assembled unit with air-cooled double casing and an

induced draught air ejector for evacuating the flue gases. This has two

advantages - shock cooling the hot flue gases thuseliminating the formation of harmful dioxins and - eliminating the need

for a flue gas fan.

Simultaneous burning of oil sludge and solid waste

PLC controlled for simultaneous burning of oil sludge and solid waste

by automatically varying the displacement of the oil sludge dosingpump to match the calorific value of the sludge, without the addition of

expensive diesel oil. Hot loading, continuous solidwaste feeding via a no-fireback sluice. (Also available with

manual feeding door)

Solid Waste only 

Hot loading, continuous solid waste feeding via a non-firebacksluice. (Also available with manual feeding door)

Sludge System

When you buy Atlas, you will never need two sludge tanks. Our

heated sludge oil treatment tanks are delivered with a transfer pump

and a mill-pump for agitation and comminution of the contents of thetank making it possible to burn oil sludge with up to 50% water

content, without additional diesel oil to the burners or having to drain

the tank. The Sludge Oil Treatment Tanks - are availablewith steam, electric or thermal oil heating.

Only one tank is required.

Diesel Oil Tanks are also available.

Sludge Oil Treatment Tanks - Dimensions

Volume (liters) 500 1200 2600

Length (mm) 1250 1750 2200

Width (mm) 800 1350 1550Height (mm) 1500 1300 1600

Page 4: New Gen Incinerator Atlas

7/30/2019 New Gen Incinerator Atlas

http://slidepdf.com/reader/full/new-gen-incinerator-atlas 4/8

L 1 L (no sluice)W (no sluice)

W

   H  Incinerator (model no.) 200 S WS 200 SL P 200 SL WS P 600 S WS

Combustion Capacity (kW) 209 209 209 581

Combustion Capacity (kcal/h) 180.000 180.000 180.000 500.000

Combustion Capacity - Solid wasteIMO spec. (kg/h) 40 40 100(l/charge) 150

Combustion CapacitySludge oil - IMO spec. (I/h) and 24 24(max. I/h) (40) (40)

Lenght L (mm) 1474

Lenght L1, standard sluice (mm) 1830 1830 2496

Lenght L1, big size sluice (mm) 2796

Width W (mm) 1524 1524 1560 1974

Height H (mm) 2070 2070 2070 2457

Outlet from incinerator ø 200 ø 200 ø 200 ø 273

Charging door opening (mm) 635*550 635*550 635*550

Waste sluice (standard) W2 350Volume feeding chamber (mm) H2 350

L2 550

Big waste sluiceVolume feeding chamber (mm)

Weight approx. (kg) 2750 2875 3000 3750

S - Solid waste, L - Sludge/Liquid waste, WS - Waste Sluice (standard), BWS - Waste sluice (big)

 New Generation Incinerators

Type 200 

Page 5: New Gen Incinerator Atlas

7/30/2019 New Gen Incinerator Atlas

http://slidepdf.com/reader/full/new-gen-incinerator-atlas 5/8

WL

       H

L 1 

L2

H2

W2

600 SL P 600 SL WS P 800 S WS 800 SL P 800 SL WS P 1200 S WS 1200 SL M 1200 SL WS M

581 581 814 814 814 1163 1163 1163

500.000 500.000 700.000 700.000 700.000 1.000.000 1.000.000 1.000.000

100 100 100 230 230250 350 500

66 66 95 95 135 135(100) (100) (140) (140) (200) (200)

2044 2434 2894

2496 2886 2886 3346 3346

2796 3186 3186 3646 3646

1974 1974 1987 1987 1987 2102 2102 2102

2457 2457 2842 2842 2842 2942 2942 2942

ø 273 ø 273 ø 406 ø 406 ø 406 ø 406 ø 406 ø 406

635*550 635*550 635*550 635*550 635*550

W2 350 W2 350 W2 350H2 350 H2 350 H2 350L2 550 L2 550 L2 550

W2 630 W2 630 W2 630H2 470 H2 470 H2 470L2 550 L2 550 L2 550

4000 4250 4525 4650 4950 5600 5700 6100

P - PLC-control unit, M - Integrated Mixer Tank and PLC-control unit

Dimensions and Capacity 

Type 600 - 800 - 1200 

Page 6: New Gen Incinerator Atlas

7/30/2019 New Gen Incinerator Atlas

http://slidepdf.com/reader/full/new-gen-incinerator-atlas 6/8

COMPONENTS

1. Charging Door

2. Combustion Chamber

3. Afterburning Chamber4. Second Afterburning

Chamber

5. Oil Burner with Built-inPump

6. Ash Cleaning Door7. Air Blower8. Induced Draught Air

Ejector

9. Sluice for Solid Waste10. Sludge Burner

11. Double Air-cooling Wall

12. Combustion Air Inlets13. Oil Sludge Mixing Tank

14. Mill Pump

15. Circulation Pump16. Compressed Air

17. Sludge Dosing Pump

18. Heating Element19. Diesel Oil Tank

20. Damper

CONNECTIONS

WORKING DIAGRAM -

 ATLAS INCINERATORS

a) Sludge Oil Inlet

b) Steam Inlet

c) Steam Outletd) Sludge Oil Ventilation Outlet

e) Diesel Oil Inletf) Diesel Oil Ventilation Outletg) Compressed Air Inlet

h) Electrical Power Supply

i) Flue Gas Outlet

INCINERATORS

g.

a.d.

e.f.

c.b.

h.i.

Page 7: New Gen Incinerator Atlas

7/30/2019 New Gen Incinerator Atlas

http://slidepdf.com/reader/full/new-gen-incinerator-atlas 7/8

INCINERATORS

Certificates:

Atlas Incinerators have been examined and tested in

accordance with IMO’s Resolution MEPC. 76 (40)adapted on September 25, 1997 - Tested according tostandard specification for shipboard incinerators -

adapted on September 26, 1997 - and in accordance to

the Guidelines for the Implementation of Annex V ofMARPOL 73/78, as well as fulfilling MARPOL Annex VI.

MED Type Approval Certificate

USCG Certificate

Type Approval from the leading Classification Societies.

 A   P  P

  R  O  V A 

  L ATLAS

INCINERATORS

 New Generation

Agent Representation in:

AlgeriaArgentinaAustraliaBaltic StatesBrazilCanadaChileChina

Columbia/VenezuelaCroatiaFinlandFranceGermanyGreeceHollandIcelandIndiaIndonesiaItalyKorea

NorwayMalaysiaMonacoMoroccoPhilippinesPolandPortugalRomaniaRussiaSingaporeSpain

TaiwanThailandTunesiaTurkeyUkraineUnited KingdomUnited Arab EmiratsUSAVietnam

Page 8: New Gen Incinerator Atlas

7/30/2019 New Gen Incinerator Atlas

http://slidepdf.com/reader/full/new-gen-incinerator-atlas 8/8

For further information contact us or our representative:

 Atlas ContainerizedIncinerators10’ & 20’ ISO containers

Standard Equipment:

IncineratorOil Sludge Tank

Diesel Oil Tank

Lighting System

CO2 Fire Fighting EquipmentVentilation

ChimneyExternal Emergency Switch

Plus external hook up forelectric power and all pipe

connections

 Atlas Skid MountedIncinerators

Standard Equipment:

IncineratorSludge Oil Tank

Diesel Oil Tank

Plus all pipelines, electric

cables, and necessary

components mounted on acommon base

   C   T   V  o  r   d   i  n  g   b  o  r  g   A   /   S

   5   5   3   7   0   0   0   9

   N  o .   0

   1   E

Atlas Incinerators A/SP.O. Box 143

Masnedoevej 73

DK - 4760 Vordingborg

Denmark

Phone +45 55 34 66 55

Fax +45 55 37 66 33

[email protected]

www.atlasinc.dk

Agent: