Page 1: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

Zoo

m 8

0 C

on

ne

ctio

n g

uid

e

Page 2: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station
Page 3: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

Zoom 80 Connection Guide

March 2013

Page 4: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

WARNINGS

In writing this manual every care has been taken to offer the most updated, correct and clear

information possible; however unwanted errors are always possible and information can be subject to

change. LSE S.r.l. cannot assume any liability resulting from the use of this manual and the same is true

for every person or company involved in the creation, production or distribution of this manual. This

manual is protected by copyright. Reproduction of this manual, even partial, in the absence of written

authorization by LSE S.r.l. is prohibited by law.

Trademarks

Windows is a registered trademark of Microsoft Corporation in the United States and elsewhere.

Bluetooth is a registered trademark of Bluetooth SIG, Inc.

AutoCAD is a registered trademark of AutoDesk Inc.

All other trademarks are trademarks of their respective owners.

Page 5: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

5

Index

WARNINGS ............................................................................................................................................ 4

Trademarks............................................................................................................................................... 4

Index ..................................................................................................................................................... 5

Introduction .......................................................................................................................................... 7

Configure Zoom 80 ................................................................................................................................ 8

Instrument profile creation in XPAD and first use ...............................................................................10

Successive uses ....................................................................................................................................15

Page 6: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station
Page 7: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

Introduction - 7

Introduction

This guide explains how to perform the first connection between the XPAD software and robotic total

station GeoMax Zoom 80 equipped with Long Range Bluetooth device.

Before proceeding with the instructions, make sure that:

The handle ZRT81 has been properly installed on the station Zoom80.

XPAD is installed and running on the controller Getac PS236 is equipped with special cap Bluetooth

Long Range.

XPAD version is 2.4.000 or later

XPAD Robotic module have to be active

To check the version of XPAD start the program and click on the icon on the upper left corner.

To check XPAD modules, press the button License and then the button Modules.

Page 8: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

8 - Configure Zoom 80

Configure Zoom 80

Before to start the connection, you must perform the appropriate settings on Zoom80 Robotic Total

Station.

1. Switch on Zoom 80 total station

2. Select option 5. Configuration

3. Select option 4. Interfaces

4. Select GeoCOM Mode item and press EDIT button:

Page 9: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

Configure Zoom 80 - 9

5. Set Use Interface item to Yes.

6. Set Port item to Port 2 (Handle)

7. Press DEVCE button.

8. Select item ZRT81 and press CONT button. If ZRT81 item is not available press SHIFT button on total

station keyboard and then press button DEFLT: ZRT81 device should have to appear in the list and

then press CONT button.

Page 10: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

10 - Instrument profile creation in XPAD and first use

9. Press CONT button to come back to main window.

Instrument profile creation in XPAD and first use

After you have properly configured the Zoom80 robotic total station you can proceed with the

configuration of XPAD running on Getac PS236 controller.

1. Start XPAD from Getac PS236 controller

2. Select Select instrument item

3. Press New button to create a new instrument profile. To requests for the type of instrumentation

select the Total station (TPS).

Page 11: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

Instrument profile creation in XPAD and first use - 11

4. Assign a name to the profile. To Brand item select GeoMax and to Model item select Zoom 80

BTLR.

5. Press Next and to Communication item select Bluetooth. If you already have Bluetooth devices

used by other profiles, open the Device list and scroll to the end, select the last item Find device. If

there is no Bluetooth device, device management window will be open directly.

Page 12: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

12 - Instrument profile creation in XPAD and first use

6. Press row “Click here to scan for a device” and wait the scanning of the available bluetooth devices.

7. From the list of the founded devices select the one that corresponds to Zoom 80 total station and

press End button.

Page 13: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

Instrument profile creation in XPAD and first use - 13

8. Press Back button to come back to the profile configuration window; on Device item select

Bluetooth device that corresponds to the Zoom 80 total station.

9. Press Next button and not define, for the moment, any target search area.

Page 14: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

14 - Instrument profile creation in XPAD and first use

10. In this phase it is possible to define the following parameters:

Angles update frequency: XPAD is able to continuously request current angle values to total station

and display them graphically in the various working windows; this parameter allows you to set how

often to display the updated values. We recommend a value of 2 times per second.

Auto-turn in stakeout: when this option is active XPAD will perform an automatic rotation and

positioning on the direction of the point that have to be staked in the field..

Search after lost: in case of loss of prism, with this option enabled, XPAD perform an automatic

search of the prism after 5 seconds after loss of the engagement.

Remote control: this option specifies that you are running XPAD on the pole of the target and not

from the station side.

Page 15: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

Successive uses - 15

11. Press End to complete the creation of the profile.

12. Select profile just created and press Current button in order to define the profile that have to be

used by XPAD.

13. Press Back button to complete the procedure and start the connection. XPAD will connect to total

station and then it will be possible to start to work.

Successive uses

The profile that has been created has been stored and can be recalled at any time without having to set

again all parameters.

After the first start, you can continue to use the last profile used in the previous session.

Page 16: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station

16 - Successive uses

1. Start XPAD from Getac PS236 controller

2. If you are using the same instrumentation of the previous session select Last instrument item

otherwise select the Select instrument item and proceed to the selection or creation of another

profile.

Page 17: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station
Page 18: New GeoForce - Manuale · 2014. 2. 7. · Introduction - 7 Introduction This guide explains how to perform the first connection between the X PAD software and robotic total station