new mooney products - ohio gas association...6 mooney® slam shut - features of the 2” – 4”...

27
Mooney® New Products Gleb Maksimov 3/17/2011 Regulation and Control Division

Upload: others

Post on 21-Mar-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

Mooney® New Products

Gleb Maksimov3/17/2011

Regulation and Control Division

Page 2: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

1

Mooney® Slam Shut

Dresser, Inc. introduces the Mooney® Slam Shut

Available with or without the Flowgrid® RegulatorPatents Pending

1” Mooney®Flowgrid®Slam Shut

Regulator and Series 41D Controller

2” Mooney®Flowgrid®Slam Shut

Regulator and series 50D Controller

Page 3: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

2

Mooney® Slam Shut

Examples of 2” units, both shown with the Series 50D (Dual Function) Controller

Mooney® Flowgrid®

Slam Shut RegulatorMooney® Slam Shut

Page 4: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

3

Mooney® Slam Shut

2” – 4” Controllers

Series 50 Single Function Controller Series 50D Dual

Function ControllerFor under pressure ORover pressure protection For under pressure AND/OR

over pressure protection

(Dual Sense Ports Available)

Page 5: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

4

Mooney® Slam Shut

2”, 3” and 4” Shut Off Valve Assemblies

Page 6: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

5

Mooney® Slam Shut - Features of the 1” design

• Easy to maintain; only two bolts required to remove entire Slam Shut assembly

• Resistant to sticking due to freezing water or debris in pipeline

• Excellent performance and accuracy across a large pressure range with a simple spring change.

• External visual indicator to show when unit is tripped.

• Easy to reset; only three caps need to be removed for complete reset.

• No pressure differential requirements for full shutoff.

Page 7: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

6

Mooney® Slam Shut - Features of the 2” – 4” design

• Bubble tight shutoff with floating flapper valve design.

• Water tight for below grade vault installations.

• Can be ordered with or without an integral Flowgrid® regulator.

• Can be retrofitted to existing 2” – 4” Flowgrid®

regulators.

• Resistant to vibration and inlet pressure variation eliminating nuisance trips.

• Available with over pressure protection, under pressure protection, or a combination of both.

• High Accuracy

Page 8: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

7

Mooney® Slam Shut

• Linear actuation.• Unique body casting and unique controller.

• Can not be retrofitted to existing Flowgrid Regulators

• Multiple connection options NPT, SWE and RF Flange (up to Class 300 only)

• Available with a Single or Dual Function Controller (Series 41 or 41D).

1” and 1 ¼” Design

Page 9: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

8

Mooney® Slam Shut

• Same modular design as existing Flowgrid® models.

• Can be retrofitted to existing Flowgrid® Regulators (up to Class 300 only)

• Multiple Flange Options (up to Class 300 only)*exceptions include flangeless, and type A.

2” – 4” Design

Page 10: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

9

Mooney® Slam Shut Retrofit

•2” through 4” Flowgrid®

regulators can be retrofitted with the Slam ShutRetrofit Kits Include;

•Shutoff Valve Assembly•Fasteners

•Body Seal

•Series 50 or 50D Controller

Page 11: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

10

Mooney® Slam Shut - Set Point Ranges

2” – 4” Sizes.

1” Sizes.

Page 12: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

11

Mooney® Slam Shut Operation

Slam Shut Operation (1”)

Upset condition is

sensed, latch mechanism is retracted

The spring then forces the linear

plug to close

Page 13: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

12

Mooney® Slam Shut Operation

Normal OperationOver Pressure or Under Pressure Condition Occurs

Upset Condition is

Sensed

Actuator releases the Pawl Lever

Causing the Flapper Valve to Close

Upstream Pressure Assists in Sealing the Flapper

Valve has Slammed ShutSlam Shut Operation (2” – 4”)

Page 14: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

13

Mooney® Slam Shut - False Trip Prevention

Normal Operating ConditionPressure slowly increases, nearly reaching the trip pressure

Controller begins to vent

Pressure returns to normal

Latch Mechanism remains stationary

Page 15: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

14

Mooney® Slam Shut - False Trip Prevention

In this situation, the design of our competitor’s latching mechanism may not reseat itself and is now susceptible to false trip due to vibration.

Page 16: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

15

Mooney® Slam Shut - False Trip Prevention

Dresser’s snap acting latch has no intermediate position. This unique feature prevents future false trips!

Page 17: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

16

Mooney® Slam Shut ResettingAfter an upset condition has occurred

• Close block valves upstream and downstream

• Then equalize the line pressure

•Reset the Slam Shut with common hand tools• Open block valves to restore flow.

• The Slam Shut is once again providing downstream pressure protection

* Reset lever is also accessible on the opposite

side of the Slam Shut.

Page 18: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

17

Mooney® Slam Shut Resetting

Resetting the 1” is similar with the exception that the reset motion is linear vs. rotary.

A simple tool (such as a screwdriver) is inserted in the reset shaft and is then used as a handle to pull the shaft downward.

With the reset shaft held down, depress the reset pin contained beneath the reset cap.

After the upstream and downstream block valves are closed, remove the bleed cap and depress the bleed valve with a screwdriver to equalize the line pressure

Page 19: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

18

Mooney® Slam Shut - Standards & Certifications

Designed to EN-14382In process of obtaining EN-14382 certification.

ASME B16.34

Page 20: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

19

2” Flowgrid AC Port Regulator

•Dresser, Inc. introduces the 2” Flowgrid AC Port regulator to it’s Flowgrid family.

•This valve combines a 2” body with a 3” port producing a very strong piping installation with low regulator outlet

velocity.

Page 21: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

20

2” Flowgrid AC Port Regulator

•Cg of 1970 meets or exceeds competitors capacity.

•Capacity is second only to that of the Dual LP in the 2” Flowgrid product line.

•100% Throttle Plate only.

•Low Differential

Page 22: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

21

2” Flowgrid AC Port Regulator

•Soft goods consist of standard 2”and 3” Flowgrid components.

•Available with RF Flange (Class 150, 300 and 600) SWE, NPT, BWE (Class 600).

•Same top entry design as existing Flowgrid models for ease of maintenance.

Page 23: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

22CONFIDENTIAL: FOR INTERNAL USE ONLY

3D Model Library Overview

•Also contains a 2D library and a color PDF index for easier choice of model

•220+ 3D models•Comprised of Mooney® and Flexflo® regulators

Page 24: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

How Our Library Is Setup

•Our library is setup in such a way that the customer can add, remove, or change the layout however they need

• We have supplied the most common layouts for ease of use

• Models are compatible with Metric and Standard

CONFIDENTIAL: FOR INTERNAL USE ONLY

Page 25: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

24CONFIDENTIAL: FOR INTERNAL USE ONLY

Customer Benefits

Saves time/money

• Saves hours of design time

• Convenient access from one source

• More realistic/more accurate drawings• With Dresser models in place, piping layouts are easier to convey to technicians

in the field

• Receive updates about new products

Page 26: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

25

3D Model Library

Questions?

CONFIDENTIAL: FOR INTERNAL USE ONLY

Page 27: New Mooney Products - Ohio Gas Association...6 Mooney® Slam Shut - Features of the 2” – 4” design • Bubble tight shutoff with floating flapper valve design. • Water tight

Mooney® Slam Shut

Product LaunchApril 28th, 2010

Salt Lake City, Utah