2
Biometry LENSTAR LS 900 ® The solution for challenging cases New software features More speed ― up to two times faster measurement procedure Post LASIK Formula ― now including the Shammas No-History method

Upload: others

Post on 20-Jul-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: New software features - INNOVA · 2018-07-12 · Gartenstadtstrasse 10 3098 Koeniz, Switzerland Phone HAAG-STREIT AG +41 31 978 01 11 +41 31 978 02 82 info@haag-streit.com The optical

Biometry

LENSTAR LS 900®

The solution for challenging cases

New software features More speed ― up to two times

faster measurement procedure Post LASIK Formula ―

now including the Shammas No-History method

DemandingCases.indd 1 08.09.2011 14:17:57

Page 2: New software features - INNOVA · 2018-07-12 · Gartenstadtstrasse 10 3098 Koeniz, Switzerland Phone HAAG-STREIT AG +41 31 978 01 11 +41 31 978 02 82 info@haag-streit.com The optical

Gartenstadtstrasse 103098 Koeniz, SwitzerlandPhone Fax

HAAG-STREIT AG

+41 31 978 01 11+41 31 978 02 82

[email protected]

The optical biometer for challenging cases Improved measurement algorithm, up to two times faster. More patient comfort with a continuous data acquisition process. Now IOL calculation on post LASIK and PRK patients with no

clinical history available.

1 Wang L, Hill WE, Koch DD. Evaluation of intraocular lens power pre- diction methods using the American Society of Cataract and Refractive Surgeons Post-Keratorefractive Intraocular Lens Power Calculator. Cataract Refract Surg. 2010 Sep;36(9):1466-73.2 McCarthy M, Gavanski GM, Paton KE, Holland SP. Intraocular lens power calculations after myopic laser refractive surgery: a comparison of methods in 173 eyes. Ophthalmology. 2011 May;118(5):940-4.

Speed-up your workfl ow� e new measurement procedure allows the user to improve the measurement speed up to two times. Internal tests showed that the time neces-sary to acquire a complete examination of 5 repe-titive measurements on both eyes on a cooperative patient has been reduced to only 90 seconds in ave-rage. � e measurement routine now is continuous and the analysis of the individual results runs in the background, thus leading to a smooth measu-rement procedure. � is not only leads to up to two times more speed but also to more patient comfort.

Post LASIK calculation� e Shammas Non-History1,2 formula included with i4.000 of EyeSuite provides the user with an easy to use formula for myopic as well as hyper-opic post LASIK patients. � e formula does not need any clinical history to work with. Simply select Shammas Non-History from the formula list and the result is immediately displayed. Even though the Shammas Non-History formula is a handy and accurate tool to directly calculate post LASIK eyes with EyeSuite IOL, it remains the re-commendation of Haag-Streit to rely speci� cally for those very demanding cases not only on the result of one formula but to consult the ASCRS post refractive calculator (http://iol.ascrs.org/)1 online and get the result of all calculation proce-dures available based on the data entered.

New LENSTAR LS 900® So� ware provides the user with an improved measurement algorithm leading to up to two times more speed in the measurement acquisition. In parallel the Shammas No-History method for the calculation of post LASIK and PRK eyes has been introduced. It enables for IOL calculation in cases whe-re no clinical history is available.

1511

.7220

358.0

2000

/ 09

.2011

DemandingCases.indd 2 08.09.2011 14:19:13