23
TYPES OF AIR AMPLIFIERS WHAT ARE THEY - REASONS TO USE AIR AMPLIFIERS Blowoff, clean, cool and dry as well as vent and exhaust with no moving parts AIR AMPLIFIERS TM NEX FLOW 4 No moving parts. 4 Compact design, simple, lightweight and portable. 4 Driven by air not electricity. 4 Replaces fans used for blowoff, cleaning, drying, cooling and conveying. 4 High airflow amplification. 4 Instant on-off, no electricity or explosion hazard. ADJUSTABLE AIR AMPLIFIER: made of anodized aluminum or stainless steel for high temperature or food applications. The customer can set the gap and lock it in place using a lock ring. Three sizes are available. 4 Compact design, simple, lightweight and portable. 4 Driven by air, not electricity for safety. 4 No moving parts hence safer and maintenance free. 4 Each end can be dusted for light conveying applications. 4 Longer life in difficult environments than competitive models. 4 Lower compressed air consumption than ejectors and venturi. 4 Maintenance free with output easily controlled, safe to use. Air Amplifiers or “Air Movers” are a simple, inexpensive device with virtually no maintenance that can convey fumes, smoke, light weight materials, and move a high volume of air for cooling, blowoff and drying applications. They use the “coanda effect” which entrains a large amount of surrounding air using only a small amount of compressed air. The effect is an amplification of up to 17 times the airflow or more (depending on the size) with reduced noise levels. Using only compressed air, the output flow and vacuum is easily controlled by adjusting or opening the air gap and/or inlet pressure. Either end of the amplifier may be ducted to address all kinds of applications from bringing in fresh air into an area to removing nasty fumes. Be wary of extremely high unrealistic or unsubstantiated amplification ratios claimed by some companies. The fixed unit being made of heavy duty zinc die cast is more ideal in rough environments where corrosion is not an issue. The aluminum Adjustable Air Amplifiers are light-weight and flexible because of being adjustable. Stainless steel adjustable units are meant for corrosive environments and for food/pharmaceutical applications. Special designs are available to meet unique customer specifications. Specially treated stainless steel units have been made for a specific medical application and threaded adjustable versions have been made for a machine builder. Different materials can be provided as well as special sizes to fit any specific application. STANDARD “FIXED” AIR AMPLIFIER: made of zinc die cast system is solid and perform as well or better than many supposedly patented designs when used in similar applications. The gap can be adjusted by adding shims. Five sizes are available. AIR AMPLIFIER FEATURES: AIR AMPLIFIER BENEFITS: AIR AMPLIFIER ADVANTAGES OVER FANS: SPECIAL DESIGNS SELECTION Nex FlowAir Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001 Q 1 D 1 AIR AMPLIFIERS AIR AMPLIFIERS Mounting and holding systems are available for the Air Amplifiers. Fully flexible positioning. See Accessories

Upload: others

Post on 18-Jan-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TYPES OF AIR AMPLIFIERS

WHAT ARE THEY - REASONS TO USE

AIR AMPLIFIERS Blowoff, clean, cool and dry as well as vent and exhaust with no moving parts

AIR AMPLIFIERSTMNEX FLOW

4 No moving parts. 4Compact design, simple, lightweight and portable.4Driven by air not electricity. 4Replaces fans used for blowoff, cleaning, drying, cooling

and conveying.4High airflow amplification. 4Instant on-off, no electricity or explosion hazard.

ADJUSTABLE AIR AMPLIFIER:

made of anodized aluminum or

s t a i n l e s s s t e e l f o r h i g h

temperature or food applications.

The customer can set the gap and

lock it in place using a lock ring.

Three sizes are available.

4 Compact design, simple, lightweight and portable.

4Driven by air, not electricity for safety.

4No moving parts hence safer and maintenance free.

4Each end can be dusted for light conveying applications.

4Longer life in difficult environments than competitive models.

4Lower compressed air consumption than ejectors and venturi.

4Maintenance free with output easily controlled, safe to use.

Air Amplifiers or “Air Movers” are a simple, inexpensive device

with virtually no maintenance that can convey fumes, smoke,

light weight materials, and move a high volume of air for

cooling, blowoff and drying applications. They use the

“coanda effect” which entrains a large amount of surrounding

air using only a small amount of compressed air. The effect is

an amplification of up to 17 times the airflow or more

(depending on the size) with reduced noise levels. Using only

compressed air, the output flow and vacuum is easily

controlled by adjusting or opening the air gap and/or inlet

pressure. Either end of the amplifier may be ducted to address

all kinds of applications from bringing in fresh air into an area

to removing nasty fumes. Be wary of extremely high

unrealistic or unsubstantiated amplification ratios claimed by

some companies.

The fixed unit being made of heavy duty zinc die cast is more ideal in rough environments where corrosion is not an issue. The aluminum Adjustable Air Amplifiers are light-weight and flexible because of being adjustable. Stainless steel adjustable units are meant for corrosive environments and for food/pharmaceutical applications.

Special designs are available to meet unique customer

specifications. Specially treated stainless steel units have

been made for a specific medical application and threaded

adjustable versions have been made for a machine builder.

Different materials can be provided as well as special sizes to

fit any specific application.

S TA N D A R D “ F I X E D ” A I R AMPLIFIER: made of zinc die cast system is solid and perform as well or better than many supposedly patented designs when used in similar applications. The gap can be adjusted by adding shims. Five sizes are available.

AIR AMPLIFIER FEATURES:

AIR AMPLIFIER BENEFITS:

AIR AMPLIFIER ADVANTAGES OVER FANS:

SPECIAL DESIGNS

SELECTION

Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001

Q

1D1

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Mounting and holding

systems are available for

the Air Amplifiers. Fully

flexible positioning. See

Accessories

Page 2: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW

Model AM20: 14:1

Model AM40: 15:1

Model AM75: 15:1

Model AM125: 16:1

AMPLIFIERS-RATIOS (APPROX.)

Model AM10: 6.5:1

A small amount of compressed air enters the annular

chamber at point (A). That is then throttled through a small

ring nozzle at high velocity and into the inside of the

Amplifier over a “coanda” profile. The compressed air

stream clings to the “coanda” profile as it enters the inside

walls of the amplifier and thereby creating a vacuum that

induces the outside air at point (B). Converting the

pressure into amplified airflow. The amplified airflow

leaves at the exit at point (C). Airflow is further amplified

downstream at point (D). By entraining additional air from

the surroundings at the exit.

STANDARD AIR AMPLIFIER - HOW IT WORKS:

OUTSIDE DIAMETER

OF OUTLETOUTSIDE DIAMETER

OF OUTLETC D E F G H

19 mm

1-1/4"

31 mm

2"

51 mm

4"

101 mm

8"

200 mm

*A

0.39

10

0.79

20

1.57

40

2.95

75

4.92

125

B

1.30

33

1.85

47

3.15

80

5.90

150

10.39

264

0.98

25

1.50

38

2.95

75

4.91

125

7.08

180

1.77

45

2.40

61

3.58

91

6.89

175

-

-

2.28

58

3.03

77

4.13

105

8.46

215

-

-

0.20

5

0.27

7

0.27

7

0.53

13

-

-

0.16

4

0.20

5

0.27

7

0.55

4

-

-

0.59

15

0.59

15

0.78

20

1.19

30

0.79

20

0.73

19

1.22

31

2.00

51

3.97

101

7.79

200

J

1.55

40

2.16

55

2.91

74

5.90

150

16.73

425

I

1/8"

1/4"

3/8"

1/2”

3/4”

AM10

A 20M

A 40M

AM75

A 125M

K(NPT)

3/4”

STANDERD AIR AMPLIFIER

STANDARD AIR AMPLIFIERS

A

B

C

D

* Inside Diameter

AC

DE F

B

K

I

J

G

H

A

J

K

C

I

B H

E-mail:-Web:-

[email protected] [email protected] [email protected] www.nexflow.com www.nexflowair.com www.nex-flow.com

Q

1D2

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 3: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW

Pressure vs. Air Flow At Outlet for Model AM 10 Standard Air Amplifier

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

10(283.2) 20(566.4) 30(849.6) 40(1132) 50(1416) 60(1699)0

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

0

0

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

Pressure vs. Air Consumption for Model AM 10 Standard Air Amplifier

Air Consumption SCFM (SLPM)

2(56.6) 4(113.3) 6(169.9) 8(226.6) 10(283.2)

AM10

AMPLIFICATION RATIO = 6.5:1 (SEE ADDENDUM-I)

STANDARD AIR AMPLIFIERS

Air Flow At Outlet SCFM (SLPM)

Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001

Q

1D3

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 4: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW STANDARD AIR AMPLIFIERS

Pressure vs. Velocity At Outlet for Model AM 10 Standard Air Amplifier

Velocity At Outlet In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

pli

fie

r P

SIG

(B

AR

)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

05000(25) 10000(50) 15000(75) 20000(100) 25000(125)0

Pressure vs. Velocity 6” From Outlet for Model AM 10 Standard Air Amplifier

Velocity 6” From Outlet - Includes Downstream Entrainment In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

pli

fie

r P

SIG

(B

AR

)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0500(2.5) 1000(5.0) 1500(7.5) 2000(10)0

AM10

12"(305mm)

6"(152mm)

18"(457mm)

Ø3"(Ø76mm)

Ø4.5"(Ø114mm)

Ø7"(Ø178mm)

AIR FLOW

Distance from Outlet

Diameter of Flow Pattern

E-mail:-Web:-

[email protected] [email protected] [email protected] www.nexflow.com www.nexflowair.com www.nex-flow.com

Q

1D4

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 5: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW

Pressure vs. Air Consumption for Model AM 20 Standard Air Amplifier

Pre

ssu

re a

t In

let

of

Air

Am

pli

fie

r P

SIG

(B

AR

)

Air Consumption SCFM (SLPM)

5(141.6) 10(283.2) 15(424.8)0

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

Pressure vs. Air Flow At Outlet for Model AM 20 Standard Air Amplifier

Air Flow At Outlet SCFM (SLPM)

Pre

ssu

re a

t In

let

of

Air

Am

pli

fie

r P

SIG

(B

AR

)

50(1416) 100(2832) 150(4248) 200(5664)0

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

AMPLIFICATION RATIO (SEE ADDENDUM )= 14:1 -I

STANDARD AIR AMPLIFIERS

AM20

Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001

Q

1D5

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 6: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW STANDARD AIR AMPLIFIERS

Pressure vs. Velocity At Outlet for Model AM 20 Standard Air Amplifier

Velocity At Outlet In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

pli

fie

r P

SIG

(B

AR

)

5000(25) 10000(50) 15000(75) 20000(100) 25000(125) 30000(150)0

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

Pressure vs. Velocity 12” From Outlet for Model AM 20 Standard Air Amplifier

Velocity 12” From Outlet -Includes Downstream Entrainment In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

pli

fie

r P

SIG

(B

AR

)

0 1000(5.0) 2000(10) 3000(15) 4000(20)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

AM20

12"(305mm)

24"(610mm)

36"(915mm)

Ø3"(Ø76mm)

Ø6"(Ø152mm)

Ø8"(Ø205mm)

AIR FLOW

Diameter of Flow Pattern

Diameter from Outlet

E-mail:-Web:-

[email protected] [email protected] [email protected] www.nexflow.com www.nexflowair.com www.nex-flow.com

Q

1D6

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 7: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW

Pressure vs. Air Flow At Outlet for Model AM 40 Standard Air Amplifier

Air Flow At Outlet SCFM (SLPM)

Pre

ssu

re a

t In

let

of

Air

Am

pli

fie

r P

SIG

(B

AR

)

100(2832) 200(5664) 300(8496) 400(11328) 500(14160)0

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

Pressure vs. Air Consumption for Model AM 40 Standard Air Amplifier

Air Consumption SCFM (SLPM)

Pre

ssu

re a

t In

let

of

Air

Am

pli

fie

r P

SIG

(B

AR

)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

5(141.6) 10(283.2) 15(424.8) 20(566.4) 25(708) 30(849.6)0

AM40

AMPLIFICATION RATIO = 15:1 (SEE ADDENDUM-I)

STANDARD AIR AMPLIFIERS

Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001

Q

1D7

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 8: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW STANDARD AIR AMPLIFIERS

Pressure vs. Velocity At Outlet for Model AM 40 Standard Air Amplifier

Velocity At Outlet In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

5000(25) 10000(50) 15000(75) 20000(100) 25000(125)0

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

Pressure vs. Velocity 12” From Outlet for Model AM 40 Standard Air Amplifier

Velocity 12” From Outlet - Includes Downstream Entrainment In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

pli

fie

r P

SIG

(B

AR

)

0 1000(5.0) 2000(10) 3000(15) 4000(20) 5000(25)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

AM40

12"(305mm)

24"(610mm)

36"(915mm)

Ø10"(254mm)

Ø6"(Ø152mm)

Ø8"(Ø205mm)

AIR FLOW

Distance from Outlet

Diameter of Flow Pattern

E-mail:-Web:-

[email protected] [email protected] [email protected] www.nexflow.com www.nexflowair.com www.nex-flow.com

Q

1D8

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 9: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW

Pressure vs. Air Flow At Outlet for Model AM 75 Standard Air Amplifier

Air Flow At Outlet SCFM (SLPM)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

100(2832) 200(5664) 300(8496) 400(11328) 500(14160) 700(19824) 800(22656)600(16992)0

Pressure vs. Air Consumption for Model AM 75 Standard Air Amplifier

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

Air Consumption SCFM (SLPM)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

10(283.2) 20(566.4) 30(849.6) 40(1132) 50(1416) 60(1699)0

AMPLIFICATION RATIO = 15:1 (SEE ADDENDUM - I)

STANDARD AIR AMPLIFIERS

AM75

Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001

Q

1D9

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 10: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW STANDARD AIR AMPLIFIERS

Pressure vs. Velocity At Outlet for Model AM 75 Standard Air Amplifier

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

Velocity At Outlet In ft/min (m/sec)

2000(10) 4000(20) 6000(30) 8000(40)

1409.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

0

Pressure vs. Velocity 12” From Outlet for Model AM 75 Standard Air Amplifier

Velocity 12” From Outlet - Includes Downstream Entrainment In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

1000(5.0) 2000(10) 3000(15) 4000(20)0

AM75

Ø16"(Ø407mm)

72”(1829mm)

AIR FLOW

Ø9"(Ø229mm)

Ø12"(Ø305mm)

12"(305mm)

36"(915mm)Distance from

Outlet

Diameter of Flow

Pattern

E-mail:-Web:-

[email protected] [email protected] [email protected] www.nexflow.com www.nexflowair.com www.nex-flow.com

Q

1D10

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 11: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW

Pressure vs. Air Flow At Outlet for Model AM 125 Standard Air Amplifier

Air Flow At Outlet SCFM (SLPM)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

01000(28320) 2000(56640) 3000(84960) 4000(113280)0

Pressure vs. Air Consumption for Model AM 125 Standard Air Amplifier

Air Consumption SCFM (SLPM)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

050(1416) 100(2832) 150(4248) 200(5664) 250(7080)0

AM125

AMPLIFICATION RATIO = 16:1 (SEE ADDENDUM - I)

STANDARD AIR AMPLIFIERS

Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001

Q

1D11

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 12: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW STANDARD AIR AMPLIFIERS

Pressure vs. Velocity 12” From Outlet for Model AM 125 Standard Air Amplifier

Velocity 12” From Outlet - Includes Downstream Entrainment In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

1000(5.0) 2000(10) 3000(15) 4000(20)0 5000(25) 6000(30)

Pressure vs. Velocity At Outlet for Model AM 125 Standard Air Amplifier

Velocity At Outlet In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

02000(10) 4000(20) 6000(30) 8000(40) 10000(50)0 12000(60)

AM125

Ø9"(Ø229mm)

Ø12"(Ø305mm)

Ø16"(Ø407mm)

12"(305mm)

36"(915mm)

72”(1829mm)

Distance from

Outlet

Diameter of Flow

Pattern

E-mail:-Web:-

[email protected] [email protected] [email protected] www.nexflow.com www.nexflowair.com www.nex-flow.com

Q

1D12

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 13: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW STANDARD AIR AMPLIFIERS

CAST ZINC FIXED STANDARD AIR AMPLIFIERS

Using Model AM20 Air Amplifiers to cool castings, cooling time was reduced by 20%

Two Model AM40 Air Amplifiers vent fumes from a tank quickly & efficiently

Water

Fumes

3/4” Zinc Alloy Amplifier

1-1/4” Zinc Alloy Amplifier

2” Zinc Alloy Amplifier

4” Zinc Alloy Amplifier

8” Zinc Alloy Amplifier

3/4” Amplifier plus Filter with Auto Drain

1-1/4” Amplifier plus filter with auto drain 2” Amplifier plus Filter with Auto Drain

4” Amplifier plus Filter with Auto Drain

8” Amplifier plus Filter with Auto Drain 3/4” Amplifier plus Filter with Auto Drain plus

Regulator with Gauge

3/4” Amplifier plus Filter with Auto Drain plus Regulator with Gauge

1-1/4” Amplifier plus Filter with Auto Drain plus Regulator with Gauge

2” Amplifier plus Filter with Auto Drain plus Regulator with Gauge

4” Amplifier plus Filter with Auto Drain plus Regulator with Gauge

8” Amplifier plus Filter with Auto Drain plus Regulator with Gauge

Stainless Steel Shim, .002" for AM 75

Stainless Steel Shim, .003" for AM 10

Stainless Steel Shim, .002" for AM 20

Stainless Steel Shim, .003" for AM 20

Stainless Steel Shim, .002" for AM 40

Stainless Steel Shim, .003" for AM 40

Stainless Steel Shim, .002" for AM 75

AM10

AM20

AM40

AM75

AM125

AM10-1

AM20-1

AM40-1

AM75-1

AM125-1

AM10-2

AM20-2

AM40-2

AM40-2

AM75-2

AM125-2

SH75-2

SH10-3

SH20-2

SH40-2

SH40-3

SH75-2

PART NO. DESCRIPTION

Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001

Q

1D13

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 14: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW

A large volume of surrounding air is induced into the

Amplifier at point (A) by the action of a small amount of

compressed air which enters the annular chamber at point

(B) that is then throttled through a small ring Nozzle at high

velocity and into the inside of the Amplifier over a coanda

profile. The compressed air stream clings to the coanda

profile as it enters the inside walls of the Amplifier and

thereby creating a vacuum that induces the outside air

converting the pressure into amplified airflow. The amplified

airflow leaves at the exit at point (C). Airflow is further

amplified downstream at point (D) by entraining additional

air from the surroundings at the exit.

Models 40002, 40002G and 40001S: 16:1

ADJUSTABLE AIR AMPLIFIER RATIOS (APPROX.)

Models 40001, 40001G and 40001S: 15:1

ADJUSTABLE AIR AMPLIFIER SPECIFICATIONS:

Normally set to .002” (.05mm) gap if greater air force is required, the gap is adjustable. The first two sizes of adjustable air amplifiers come in two versions – unmarked regular versions and marked to gauge the gap setting from 0 to 1.5 mm.

ADJUSTABLE AIR AMPLIFIER - HOW IT WORKS:

40001, 40001G, 40001S

2.0 1.25 1.0 .98 1.38 1.88 2.88 1/4”1 1/4”

2”

4”

40002, 40002G, 40002S

40003, 40003S

3.0

5.5

2.0

4.0

1.06

1.5

1.64

3.02

1.5

2.6

2.25

3.5

3.25

5.0

3/8”

1/2”

Model A B C D E F G H* NPT

50.8 31.8 25.4 24.9 35 47.8 73.219mm

51mm 76.2 50.8 26.9 41.7 38 57.2 82.6

101mm 140 102 38.1 76.7 66 89 127

ADJUSTABLE AIR AMPLIFIERS

A

B

D

C

*BSP Threads or Adaptors can be supplied depending on country location.

OUTSIDE DIAMETEROF OUTLET

E

F

G

B

D

A

AMBIENTAIR

FLOW

COMPRESSED AIR

C

HLOCK RING

ADJUSTABLE AIR AMPLIFIRE

E-mail:-Web:-

[email protected] [email protected] [email protected] www.nexflow.com www.nexflowair.com www.nex-flow.com

Q

1D14

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Models 40003 and 40003S: 17:1

Page 15: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW ADJUSTABLE AIR AMPLIFIERS

Pressure vs. Air Consumption for Model 40001, 40001G and 40001S Adjustable Air Amplifier

Air Consumption SCFM (SLPM)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

5(141.6) 10(283.2) 15(424.8) 20(566.4)0

Pressure vs. Air Flow At Outlet for Model 40001, 40001G and 40001S Adjustable Air Amplifier

Air Flow At Outlet SCFM (SLPM)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

050(1416) 100(2832) 150(4248) 200(5664) 250(7080) 300(8496)0

40001, 40001G and 40001S

AMPLIFICATION RATIO = 15:1 (SEE ADDENDUM - I)

Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001

Q

1D15

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 16: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW ADJUSTABLE AIR AMPLIFIERS

Pressure vs. Velocity At Outlet for Model 40001, 40001G and 40001S Adjustable Air Amplifier

Velocity At Outlet In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

05000(25) 10000(50) 15000(75) 20000(100) 25000(125) 30000(150)0

Pressure vs. Velocity 12” From Outlet for Model 40001, 40001G and 40001S Adjustable Air Amplifier

Velocity 12” From Outlet - Includes Downstream Entrainment In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

0 1000(5.0) 2000(10) 3000(15) 4000(20) 5000(25)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

40001, 40001G and 40001S

Model 40001 AIR AMPLIFIER SIZE 1 1/4"AIR FLOW CHART

36" (914mm)

24" (609mm)

12" (305mm)

Ø3" (Ø76mm)

Ø6" (Ø152mm)

Ø8" (Ø203mm)

Distance from Outlet

Diameter of Flow Pattern

AIR FLOW

E-mail:-Web:-

[email protected] [email protected] [email protected] www.nexflow.com www.nexflowair.com www.nex-flow.com

Q

1D16

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 17: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW ADJUSTABLE AIR AMPLIFIERS

Pressure vs. Air Consumption for Model 40002, 40002G & 40002S Adjustable Air Amplifier

Air Consumption SCFM (SLPM)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

10(283.2) 20(566.4) 30(849.6) 40(1132)0

Pressure vs. Air Flow At Outlet for Model 40002, 40002G & 40002S Adjustable Air Amplifier

Air Flow At Outlet SCFM (SLPM)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

100(2832) 200(5664) 300(8496) 400(11328) 500(14160) 600(16992)0

40002, 40002G & 40002S

AMPLIFICATION RATIO = 16:1 (SEE ADDENDUM - I)

Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001

Q

1D17

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 18: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

Pressure vs. Velocity At Outlet for Model 40002, 40002G & 40002S Adjustable Air Amplifier

Velocity At Outlet In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

00 5000(25) 10000(50) 15000(75) 20000(100) 25000(125)

Pressure vs. Velocity 12” From Outlet for 40002, 40002G & 40002S Adjustable Air Amplifier

Velocity 12” From Outlet - Includes Downstream Entrainment In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

00 1000(5.0) 2000(10) 3000(15) 4000(20) 5000(25) 6000(30)

TMNEX FLOW ADJUSTABLE AIR AMPLIFIERS

40002, 40002G & 40002S

36" (914mm)

Model 40002 AIR AMPLIFIER SIZE 2"AIR FLOW CHART

24" (609mm)

12" (305mm)

Ø6" (Ø152mm)

Ø8" (Ø203mm)

Ø10" (Ø254mm)

AIR FLOW

Distance from Outlet

Diameter of Flow

Pattern

E-mail:-Web:-

[email protected] [email protected] [email protected] www.nexflow.com www.nexflowair.com www.nex-flow.com

Q

1D18

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 19: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW ADJUSTABLE AIR AMPLIFIERS

Pressure vs. Air Consumption for Model 40003 & 40003S Adjustable Air Amplifier

Air Consumption SCFM (SLPM)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

10(283.2) 20(266.4) 30(849.6) 40(1132) 50(1416) 60(1699)0

Pressure vs. Air Flow At Outlet for Model 40003 & 40003S Adjustable Air Amplifier

Air Flow At Outlet SCFM (SLPM)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

500(14160) 1000(28320)0

40003 & 40003S

AMPLIFICATION RATIO = 17:1 (SEE ADDENDUM - I)

Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001

Q

1D19

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 20: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

Pressure vs. Velocity At Outlet for Model 40003 & 40003S Adjustable Air Amplifier

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

Velocity At Outlet In ft/min (m/sec)

2000(10) 4000(20) 6000(30) 8000(40)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

0

0

Pressure vs. Velocity 12” From Outlet for Model 40003 & 40003S Adjustable Air Amplifier

Velocity 12” From Outlet - Includes Downstream Entrainment In ft/min (m/sec)

Pre

ssu

re a

t In

let

of

Air

Am

plif

ier

PSI

G (

BA

R)

140(9.8)

120(8.4)

100(7.0)

80(5.6)

60(4.2)

40(2.8)

20(1.4)

01000(5.0) 2000(10) 3000(15) 4000(20)0

TMNEX FLOW ADJUSTABLE AIR AMPLIFIERS

40003 & 40003S

Ø12" (Ø305mm)Ø16" (Ø410mm)

AIR FLOW CHART

36" (914mm)

12" (305mm)

Ø9" (Ø229mm)

72" (1830mm)

Model 40003 AIR AMPLIFIER SIZE 4"

AIR FLOW

Distance from Outlet

Diameter of Flow

Pattern

E-mail:-Web:-

[email protected] [email protected] [email protected] www.nexflow.com www.nexflowair.com www.nex-flow.com

Q

1D20

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

Page 21: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW ADJUSTABLE AIR AMPLIFIERS

D21

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

E-mail:-Web:-

[email protected] [email protected] [email protected] www.nexflow.com www.nexflowair.com www.nex-flow.com

NEXFLOW NEXFLOW

Hot Gass

Model 40002S Stainless Steel Adjustable Air Amplifiers cool hot spots on a duct where insulation has worn awayuntil downtime can be scheduled.

NEXFLOW

DUST COLLECTOR

Model 40001 Adjustable Air Amplifier vents dust from a machining operation.

The Adjustable Air Amplifier can be adjusted to provide the blow-off force and/or vacuum required for any particular

application. Made of anodized aluminum or stainless steel for corrosive and high temperature applications the unit offers

flexibility in applications.

The Gauged Adjustable Air Amplifier with marking to indicate the settings from 0 to 1.5 mm comes in anodized aluminum for

applications where accurate gap control is required. As with the regular adjustable unit the gapis locked into place with a lock

ring.

Page 22: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW

ADJUSTABLE AIR AMPLIFIERS - ALUMINUM

ADJUSTABLE AIR AMPLIFIERS - GAUGED SETTINGS

ADJUSTABLE AIR AMPLIFIERS

40001 1-1/4” Adjustable Aluminum Air Amplifier

40002 2” Adjustable Aluminum Air Amplifier

40003 4” Adjustable Aluminum Air Amplifier

41001 1-1/4” Adjustable Aluminum Amplifier plus Filter with Auto Drain

41002 2” Adjustable Aluminum Amplifier plus Filter with Auto Drain

41003 4” Adjustable Aluminum Amplifier plus Filter with Auto drain

42001 1-1/4” Adjustable Aluminum Amplifier plus Filter with Auto Drain plus Regulator with Gauge

42002 2” Adjustable Aluminum Amplifier plus Filter with Auto Drain plus Regulator with Gauge

42003 4” Adjustable Aluminum Amplifier plus Filter with Auto Drain plus Regulator with Gauge

40001G 1-1/4” Adjustable Aluminum Air Amplifier with Gauged Settings

40002G 2” Adjustable Aluminum Air Amplifier with Gauged Settings

41001G 1-1/4” Adjustable Aluminum Air Amplifier with Gauged Settings plus Filter with Auto Drain

41002G 2" Adjustable Aluminum Air Amplifier with Gauged Settings plus Filter with Auto Drain

42001G 1-1/4” Adj. Aluminum Air Amplifier with Gauged Settings plus Filter with Auto Drain plus Regulator with Gauge

42002G 2" Adj. Aluminum Air Amplifier with Gauged Settings plus Filter with Auto Drain plus Regulator with Gauge

PART NO. DESCRIPTION

PART NO. DESCRIPTION

E-mail:-Web:-

[email protected] [email protected] [email protected] www.nexflow.com www.nexflowair.com www.nex-flow.com

Q

1D22

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS

ADJUSTABLE AIR AMPLIFIERS - STAINLESS STEEL

40001S 1-1/4” Adjustable Stainless Steel Air Amplifier

40002S 2” Adjustable Stainless Steel Air Amplifier

40003S 4” Adjustable Stainless Steel Air Amplifier

41001S 1-1/4” Adjustable Stainless Steel Amplifier plus Filter with Auto Drain

41002S 2” Adjustable Stainless Steel Amplifier plus Filter with Auto Drain

41003S 4” Adjustable Stainless Steel Amplifier plus Filter with Auto Drain

42001S 1-1/4” Adjustable Stainless Steel Amplifier plus Filter with Auto Drain plus Regulator with Gauge

42002S 2” Adjustable Stainless Steel Amplifier plus Filter with Auto Drain plus Regulator with Gauge

42003S 4” Adjustable Aluminum Steel Amplifier plus Filter with Auto Drain plus Regulator with Gauge

PART NO. DESCRIPTION

Page 23: NexFlow Catalogue Section D - Neumacontrol · 2018. 7. 10. · Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313

TMNEX FLOW

Similar to the Model: 4 001 but fixed to a handle and supplied with a filter

screen on the intake end, this unit is designed especially for cooling solvent

and water based paint surfaces quickly and efficiently.

8

The Mounting Brackets come in two versions:

Model 48002 Fixed System complete with a sturdy

stand, vertical support bar, parallel support bar

and two movable supports to hold the Dry Air

Guns or any other blowoff product from an air

knife or amplifier to jets and nozzles. The

compressed air is fed in at the bottom of the

support with hoses (supplied with the system)

feeding the blowoff units. Model 48003

Adjustable System is the same as the above except

for the adjustable parallel support bar for totally

variable support adjustments to aim the blowoff

units wherever they need to be. This simple

design allows for tremendous portability and

flexibility of use for many blowoff applications

Spray Booth Dry Air Gun System Blowoff, clean, cool and dry as well as vent and exhaust with no moving parts

SPRAY BOOTH DRY AIR GUN SYSTEM:

4Maximum inlet pressure: 10 bar (145 psig)

4Working pressure: 3-6 bar (43-87 psig)

4Air Consumption: 12.3 cfm (3501/min) at 60 psig

4Air Inlet thread ¼” NPT

SPECIFICATIONS:

MOUNTING SPECIFICATION

48001

48002

Dry Air Gun Only

48003

Fixed Mounting System

48004

Flexible Mounting System

48005

Diffuser Spare Part

PART NO. DESCRIPTION

Spare Sieve

SMART N CLEVERTM

MORE THAN INTELLIGENT

FIXED MOUNTING SYSTEM ADJUSTABLE MOUNTING SYSTEM

SPRAY BOOTH DRY AIR GUN SYSTEM

DRY AIR GUN

E-mail:-Web:-

[email protected] [email protected] [email protected] www.nexflow.com www.nexflowair.com www.nex-flow.com

Q

1D23

AIR

AM

PLI

FIER

S A

IR A

MP

LIFI

ERS