nf 1.5 diaphragm liquid pump · 2020-03-12 · nf 1.5 kpdc-m. nf 1.5 kpdcb-4. nf 1.5 kp.51dcb-4 1...
TRANSCRIPT
NF 1.5 KPDCB-4NF 1.5 KPDC-M NF 1.5 KP.51DCB-4
111
Please visit our website www.knf.com
to get more information.
flexible •custom-fit•cost
-effec
tive
KNF Modular System
NF 1.5DIAPHRAGM LIQUID PUMP
ADVANTAGES• Small and powerful
• Self-priming and excellent for pressure
• Extreme chemical resistance
• Dry running, durable and maintenance free
POSSIBLE AREAS OF USE• Analysers
• Laboratory
• Cleaning industry
• Printing
PERFORMANCE DATABasic types NF 1.5 DC-M NF 1.5 DCB NF 1.5 DCB-4Material options KP KT TTPump head PP PP PVDFDiaphragm PTFE PTFE PTFEValves EPDM FFKM FFKMFlow rate (ml/min) at atm. pressure ≥60 ≥40 ≥5 - 40Suction height (mWg) 3Pressure head (mWg) 60Permissible ambient temperature (°C) +5 to +40Permissible liquid temperature (°C) +5 to +80Weight (g) 57 50IP protection factor 30 40
ELECTRICAL DATASOperation voltage (V) 12 / 24 12 / 24 10 - 26.4Power consumption (W) 2.16 1.6 / 1.9 1.8I load max. (A) 0.18 / 0.09 0.13 / 0.08 0.15 - 0.07
NF 1.5 DCB NF 1.5 DCB-4
222
NF 1.5 DCB
NF 1.5 DCB FLOW CURVE
NF 1.5 DCB-4
NF 1.5 DCB-4 FLOW CURVE
NF 1.5 DCB-4 CONTROL CURVE
Dimensions in mm
PERFORMANCE DATASeries model Flow rate
at atm. pressure(ml/min)
Max. suction height (mWg)
Max.pressure head(mWg)
NF 1.5 DCB ≥40 3 60
PERFORMANCE DATASeries model Flow rate
at atm. pressure(ml/min)
Max. suction height (mWg)
Max.pressure head(mWg)
NF 1.5 DCB-4 ≥5 - 40 3 60
Dimensions in mm
NF1.5 KT DCB-4.xls
Diagr. Verkauf E
13.12.2010
fr
0
10
20
30
40
50
60
-30.0 -20.0 -10.0 0.0 10.0 20.0 30.0 40.0 50.0 60.0
Suction head [mWG] Pressure head [mWG]
Flo
w r
ate
[m
l/m
in]
-3.0 -2.0 -1.0
NF1.5 KT DCB-4.xls
Diagr. Verkauf E
13.12.2010
fr
0
10
20
30
40
50
60
-30.0 -20.0 -10.0 0.0 10.0 20.0 30.0 40.0 50.0 60.0
Suction head [mWG] Pressure head [mWG]
Flo
w r
ate
[m
l/m
in]
-3.0 -2.0 -1.0
NF1.5 KT DCB-4.xls
Regelbereich Diagr. Verkauf E
13.12.2010
fr
0
10
20
30
40
50
60
0.0 1.0 2.0 3.0 4.0 5.0
Control Voltage [V]
Flo
w r
ate
[m
l/m
in]
0 mWG
60 mWG
Dimensions in mm
Weitergabe sowie Vervielfaeltigung d
ieser Unterlage,
Verwertung und Mitteilung ihres Inha
lts nicht
gestattet, soweit nicht ausdruecklic
h zugestanden.
Zuwiderhandlung verpflichten zu Scha
denersatz.
Alle Rechte fuer den Fall der Patent
erteilung oder
Gebrauchsmuster-Eintragung vorbehalt
en.
Copying of this document and giving
it to others
and the use or communication of the
contents
thereof, are forbidden without expre
ss authority.
Offenders are liable to the payment
of damages.
All rigths are reserved in the event
of the grant of a
patent or the registration of a util
ity model or design.
00 Erstellt 29.09.2010 pb
. . . . .
. . . . .
Rev. Aenderungen / Modification Dat. Name Ae'Nr./Notice No.
MassstabScale 3:4
Ersetzt durchReplaced by
Ersatz fuerReplacement for
Name Dat.
Freigabe / Release
Erstellt / Drawn pb 29.09.2010
FormatSize
Toleranzen Tolerances
DIN ISO 2768-mH Material
DIN A3 <6
>6<30
>30<120
>120<400
0.1 0.2 0.3 0.5
Typ / Type Identnummer / Ident No.
NF 1.5 161586Benennung / Description Zeichnungnummer / Drawing No. Rev.
DB MASSBILD NF 1.5 __DC-M 3.7.02487 00
Kasten = 2.5 x Grösse Datenblatt
AA
1 16
51.1
18.2
26.8
23.5
8
31.5
UNF1/4"-28
8.54.75
17
248
4xTiefe 5mmdepth 5mm
2.5
37
2212.1
NF 1.5 DC-M
333
NF 1.5 DC-M
NF 1.5 DC-M FLOW CURVE
PERFORMANCE DATASeries model Flow rate
at atm. pressure(ml/min)
Max. suction height (mWg)
Max.pressure head(mWg)
NF 1.5 DC-M 60 3 60
Dimensions in mm
NF1.5 KT DC-M.xls
Diagr. Verkauf E
13.12.2010
fr
0
10
20
30
40
50
60
70
-30.0 -20.0 -10.0 0.0 10.0 20.0 30.0 40.0 50.0 60.0
Suction head [mWG] Pressure head [mWG]
Flo
w r
ate
[m
l/m
in]
-3.0 -2.0 -1.0
444
www.knf.com
KNF
rese
rves
the
right
to m
ake
tech
nica
l cha
nges
with
out n
otic
e. K
NF
01/2
019.
ww
w.k
nf.c
om
The performance values for the series models shown on this data sheet were determined under test conditions. The actual performance values may differ and depend in particular on the usage conditions and therefore on the specific application, on the parameters of the components involved in the user’s system and on any technical modifi- cations carried out which deviate from the standard configuration or the as delivered condition.
If individual designs have been created for specific customers on the basis of series models, other technical performance data may apply. Before operation begins, the relevant operating instructions and/or assembly or installation instructions should be read and the safety information contained in these instructions should be noted. KNF reserves the right to make changes to the product and the associated documen-tation without prior notice to the customer.
NSF National Sanitary FoundationThis certification will confirm that all of the pumps with the code .51 are certified for the use with foods/consumables.
DIGITAL CUSTOMIZATION Thanks to digital technology, this pump can be quickly adapted to the customer‘s system. This is done by parametrizing the firmware of the motor at KNF.
OPTIONSName Picture Details
Motors Various voltage options, higher and lower service life
Electrical connections Molex, AMP etc.
Hydraulic connections Internal thread, manifold connection etc.
ACCESSORIESDescription Illustration Details
Diaphragm pressure control valve The pressure control valve can be used for a more accurate control of flow against a fluctuat-ing back pressure, metering into a vacuum and from a pressurised system.
Pulsation damper This very versatile pulsation damper reduces the vibration in hoses ans pipes and it helps to remove pulsation which ist preventing the system from functionning correctly.
Filter KNF filters protect both pumps and other upstream instrumentation and hydraulic circuits against particulate, crystals and fibres which can improve optimum operation.
Tubing Various diameters and materials