nike/eolo maior kw - enerja.bgenerja.bg/files/eolo_maior.pdf · immergas s.p.a. · 42041 ... 24/28...

16
NIKE/EOLO Maior kW Eco-friendly wall-mounted combi and heating only system boilers

Upload: letuyen

Post on 16-Feb-2019

272 views

Category:

Documents


3 download

TRANSCRIPT

NIKE/EOLO Maior kWEco-friendly wall-mounted combiand heating only system boilers

During the life of a boiler, performance is influenced by external factors, e.g. water hardness, atmospheric agents, systemliming, etc. The published data refers to new products correctly installed and used, in accordance with local regulations.

N.B. we recommend regular periodic maintenance of the appliance.

Immergas S.p.A. · 42041 Brescello (RE) Italy · Tel. +39.0522.689011 · Fax +39.0522.689178

www.immergas.com

2

Eolo Eco24/28 kW

EOLO MAIOR24/28/32

kW

EOLO MAIOR24/28 kW

VIPEOLO Maior28 kW X

Combiversions

Eco-friendlyversions

NIKE Maior24/28 kW

NIKE Maior28 kW X

Combiversions

Heating onlyversions

Efficiency ** Stars

Open flueNatural draught

Room sealedFan assisted

Efficiency *** Stars

Heating onlyversions

Aqua CelerisSystem versions

RANGE

The number in the

name of these new

boilers indicates

the heat output

in kWTThhee mmooddeellssIImmmmeerrggaass introduce the new range of wall-mountedNIKE Maior and EOLO Maior boilers, which areavailable in the following versions

EEccoo kkWW vveerrssiioonnss,, eeccoo--ffrriieennddllyy iinnssttaannttaanneeoouussbbooiilleerrss

kkWW VViipp vveerrssiioonnss,, eeqquuiippppeedd wwiitthh tthhee ““AAqquuaaCCeelleerriiss”” ssyysstteemm

kkWW vveerrssiioonnss pprroovviiddee iinnssttaannttaanneeoouusspprroodduuccttiioonn ooff ddoommeessttiicc hhoott wwaatteerr

KKww XX vveerrssiioonnss,, ssppaaccee hheeaattiinngg oonnllyy

0051BP2538

mod. NIKE««

European Efficiency Directive 92/42

0051B02441

mod. EOLO«««

European Efficiency Directive 92/42

with reduced emissions of pollutants NOx and CO

ensuring faster supply of domestic hot water

which may be connected to a separate storage tank.

MM aaii oo

rrkk WW

new

rang

e

FFaasstt aanndd eeaassyyiinnssttaallllaattiioonn

•• TThhee 1199 ccmm cclleeaarraannccee bbeettwweeeenntthhee ccoonnnneeccttiioonnss aanndd tthhee wwaallllaalllloowwss eeaassyy wwoorrkkiinngg aacccceessssaanndd ffaacciilliittaatteess bbooiilleerrrreeppllaacceemmeenntt..

•• NNeeww aaddjjuussttaabbllee sshhuutttteerrssyysstteemm ((ffoorr EEOOLLOO mmooddeellss))wwhhiicchh ffaacciilliittaatteess aaddjjuussttmmeennttffoorr ddiiffffeerreenntt lleennggtthhss ooff fflluueeppiippee.. ((sseeee ppaaggee 1100))..

OUTDOOR INSTALLATIONThe EOLO versions are approvedfor outdoor installation inpartially protected places,allowing space saving inside thebuilding.

picture 23

These boilers are designed tooffer installation advantages innew building projects or whenreplacing old models:

•• PPaacckkaaggiinngg wwhhiicchh aalllloowwss ffaasstthhaannddlliinngg.. TThhee ppaacckkaaggiinngg iissooppeenneedd vveerrttiiccaallllyy aalllloowwiinnggeeaassyy ppoossiittiioonniinngg ooff tthhee bbooiilleerrffoorr iinnssttaallllaattiioonn.. ((SSeeee ppiicc.. 11))..

•• IInnssttaallllaattiioonn ffrraammee ssuupppplliieeddaass aa ssttaannddaarrdd ffeeaattuurree iinnoorrddeerr ttoo ppeerrmmiitt aaccccuurraatteeppllaacceemmeenntt oonn iirrrreegguullaarrwwaallllss oorr iinn ppllaacceesswwiitthh lliimmiitteeddaacccceessss.. ((sseeeeppiicc.. 22))..

MM aaii oo

rrkk WW

new

rang

e picture 1

EEaassyy ttoo uussee

4

Maior kW boilers are designedfor ease of use and includethese user friendly features:

• New simple ball filling valvefor system pressurisationand top up.

• Continuous display of boileroperating state and faultsignalling.

The new electronic modulatingcontrol board has some veryuseful functions:

• Anti-freeze protectionwhich ensures reliableoperation down to – 5°C.

• Auto-diagnosis systemfacilitates fault-findingthrough a LED.

• Automatic exercise routinefor the circulator andthree-way valve.

• Electronic low watercirculation protectionsystem.

• Reduction of DHW waitingtimes through use ofprimary circuit pre-heating.

• Possibility of control via PCor pocket PC.

• Set-up of all parametersdirectly through the controlpanel knobs, avoidingadjustment of componentson the board.

• Normal functioning evenwhen the electrical polarityof the supply is reversed.

MM aaii oo

rrkk WW

new

rang

e

OOppttiioonnss ffoorr ccoommffoorrtt aannddeeffffiicciieennccyy

5

MM aaii oo

rrkk WW

new

rang

e

FFuurrtthheerr ooppttiioonnss aarree aavvaaiillaabbllee ffoorr MMaaiioorr kkWW mmooddeellss wwhhiicchh ccaanniinnccrreeaassee ssaavviinnggss aanndd ccoommffoorrtt ffoorr tthhee eenndd--uusseerr..

AAmmiiccoo RReemmoottee CCoonnttrrooll

EEaassyy iinnssttaallllaattiioonn No need of electrical supply.

EEaassyy aanndd iinnttuuiittiivvee ccoonnttrroollssBased on traditional knobs but allowingcomprehensive control of the boilerfunctions.

OOppttiimmiisseedd ooppeerraattiioonnImproving the seasonal efficiency of theboiler and defining the ideal temperaturefor the heating system using weekly timeprogramming.

EExxtteerrnnaall SSeennssoorr

Improves the sensitivity of the system withregard to the weather, reducing consumptionfurther.

RReellaayy CCoonnttrrooll BBooaarrdd

(standard feature on EOLO Maior kW Vipmodels)fitted with three relays, it is installed onthe panel of the boiler and it allows controlof external devices such as: pumps, zonesvalves, remote alarm signals etc.

RReemmoottee FFiilllliinngg

This can only be installed when the AmicoRemote Control is used. It can restore thecorrect system water pressure withoutmanual adjustment of the filling valve.Only for EOLO models.

6

A reliable choice

Wall-mounted combi boilerswith open flue naturaldraught or sealed room fanassisted

• 5 models of 24, 28 or 32 kW

• EOLO models approved for outdoor installation inpartially protected places (see page 13)

• Possible connection to Amico Remote Control andExternal Sensor (both are optional)

• Possible connection to the relay control board(optional) for interface to external systems

OOvveerr--ssiizzeedd ppllaattee hheeaatt eexxcchhaannggeerr The heat exchanger has been over sized inorder to guarantee high performance, DHWproduction and to reduce the formation ofscale in the presence of hard water.

DDHHWWpprroodduuccttiioonn

((∆∆tt 3300ººCC)) ll//mmiinnRReegguullaattiinngg

bbyy--ppaassssMMooddeell

NNiikkee MMaaiioorr 2233,,66 (20.300) l l l l l 1111,,4424 kWNNiikkee MMaaiioorr 2288,,00 (24.040) l l l l l 1133,,3328 kWEEoolloo MMaaiioorr 2244,,00 (20.640) l l l l l 1111,,4424 kWEEoolloo MMaaiioorr 2288,,00 (24.080) l l l l l 1133,,3328 kWEEoolloo MMaaiioorr 3322,,00 (27.520) l l l l l 1155,,2232 kW

HHeeaatt oouuttppuutt((kkccaall//hh))

SSeeaalleeddcchhaammbbeerr

NNaattuurraallddrraauugghhtt

EElleeccttrroonniicciiggnniittiioonn aannddmmoodduullaattiioonn

IInnssttaannttaanneeoouussDDHHWW

pprroodduuccttiioonn

1166 ppllaatteess ffoorr mmooddeellss ooff 2244 kkWW

2200 ppllaatteess ffoorr mmooddeellss ooff 2288 kkWW

2222 ppllaatteess ffoorr mmooddeellss ooff 3322 kkWW

IIPPXX44DD

NNIIKKEE//EEOOLLOO MMaaiioorr kkWWMMaaiioorr kkWW nneeww rraannggee

MMaaiioorr kkWW nneeww rraannggee

7

Wall-mounted eco-friendlycombi boilers room sealedfan assisted

• Reduced pollutant emissions and high efficiency(*** stars according to European Directive 92/42)

• Approved for outdoor use in partially protectedplaces (see page 13)

• Possible connection to Amico Remote Control andExternal Sensor (both are optional)

• Possible connection to the relay control board(optional) for connection to external systems

Classification of boilers according to NOxemissions. (in mg/kWh)

300

250

200

150

100

50

0Class 1 Class 2 Class 3 Class 4 Class 5 Emissions

EOLO Eco24 kW

260

200

150

10070

40

EEOOLLOO EEccoo 2244,,00 (20.640) l l l l l l 1111,,4424 kWEEOOLLOO EEccoo 2288,,00 (24.080) l l l l l l 1133,,3328 kW

EEnnvviirroonnmmeennttaallllyy--ffrriieennddllyy,,hhiigghh eeffffiicciieennccyy

EEnnvviirroonnmmeennttaallllyy ffrriieennddllyy bbuurrnneerrEuropean standards (EN 297 and EN 483)classify boilers in 5 classes according totheir NOx emissions. In order to meet therequirements of the 5th class (the most eco-friendly one) the boilers must haveemissions of NOx lower than 70mg/kWh.

DDHHWWpprroodduuccttiioonn

((∆∆tt 3300ººCC)) ll//mmiinnRReegguullaattiinngg

bbyy--ppaassssMMooddeell HHeeaatt oouuttppuutt((kkccaall//hh))

SSeeaalleeddcchhaammbbeerr

BBuurrnneerrffoorr NNOOxxaanndd CCOO

EElleeccttrroonniicciiggnniittiioonn aannddmmoodduullaattiioonn

IInnssttaannttaanneeoouussDDHHWW

pprroodduuccttiioonnIIPPXX44DD

EEOOLLOO EEccoo kkWW

8

Wall-mounted combiboilers room sealed fanassisted with Aqua CelerisSystem

• High efficiency («««stars according to EuropeanDirective 92/42)

• Approved for outdoor installation in partiallyprotected places (see page 13)

• Possible connection to Amico Remote Control andExternal Sensor (both optional)

• Possible connection to the relay control board(optional) for connection to external systems

Hot water and something more

EOLO Maior 24,0 (20.640) l l l l l l 11,424 kW VipEOLO Maior 28,0 (24.080) l l l l l l 13,328 kW Vip

IImmmmeeddiiaattee hhoott wwaatteerr!! AAllwwaayyss!!Aqua Celeris is the new Immergas patented system for the rapid delivery ofdomestic water at the right temperature with reduced waiting times. Itconsists of a mini storage tank installed on the primary circuit featuring aspecial modulating electric heater that provides the following advantages:• Instant DHW delivery• Water savings because the domestic water reaches the right temperaturealmost immediately• Long term maintenance. Aqua Celeris is connected to the primary circuittherefore it avoids scale deposits on the surfaces of the mini storage tankgiving long term lower maintenance.

Hot water

comfort««« stars

DDHHWWpprroodduuccttiioonn

((∆∆tt 3300ººCC)) ll//mmiinnRReegguullaattiinngg

bbyy--ppaassssMMooddeell HHeeaatt oouuttppuutt((kkccaall//hh))

SSeeaalleeddcchhaammbbeerr

““AAqquuaaCCeelleerriiss””ssyysstteemm

EElleeccttrroonniicciiggnniittiioonn aannddmmoodduullaattiioonn

IInnssttaannttaanneeoouussDDHHWW

pprroodduuccttiioonn IIPPXX44DD

EEOOLLOO MMaaiioorr kkWW VViippMMaaiioorr kkWW nneeww rraannggee

Wall-mounted heating onlysystem boilers open fluenatural draught or roomsealed fan assisted

• Model that provides space heating only: thanks to aspecial optional kit, it is possible to combine theboiler to a separate AISI 316 L stainless steelstorage tank of 80, 105, 120 or 200 litres.

• Modulating output from 10,5 to 28 kW ensures theadaptation of the boiler to the effective thermalneed of the system

• Possible connection to Amico Remote Control andExternal Sensor (both options)

Heating only

NNIIKKEE MMaaiioorr 2288,,00 (24.040) l option l l l28 kW XEEOOLLOO MMaaiioorr 2288,,00 (24.080) l option l l l28 kW X

KKiitt ttoo ccoonnnneecctt tthhee ssttoorraaggee ttaannkkThanks to this kit (option) it is possible toconnect a separate storage tank in order toimplement the production of domestic hotwater

Immergas manufacturesstorage tanks of 80, 105, 120

and 200 litres capacity

9

RReegguullaattiinnggbbyy--ppaassss

EElleeccttrroonniicciiggnniittiioonn aannddmmoodduullaattiioonn

MMooddeell HHeeaatt oouuttppuutt((kkccaall//hh))

SSeeaalleeddcchhaammbbeerr

AArrrraannggeemmeenntt ffoorrsseeppaarraattee ssttoorraaggee

ttaannkk NNaattuurraallddrraauugghhtt

NNIIKKEE//EEOOLLOO MMaaiioorr kkWW XX

IIPPXX44DD

CCoonnnneeccttiioonn ttoo ssoollaarr ppaanneellssThe storage tank of 200 l. is arranged for theconnection to solar panels thanks to a special

external connection kit (option). The bestsolution for ecological saving.

MMaaiioorr kkWW nneeww rraannggee

Circulating pump graph

24 kW ModelsNIKE/EOLO Maior 24 kW • EOLO Eco 24 kW •

EOLO Maior 24 kW Vip

32 kW ModelsEOLO Maior 32 kW

28 kW ModelsNIKE/EOLO Maior 28 kW • NIKE/EOLO Maior 28 kW X •

EOLO Eco 28 kW • EOLO Maior 28 kW Vip

80

70

60

50

40

30

20

10

0

8.16

7.14

6.12

5.10

4.08

3.06

2.04

1.02

00 200 400 600 800 1000 1200 1400 1600 1800 2000 2200

Circulator flow rate / head graph

Flow rate (l/min)

Head

(kp

a)

Head

(kp

a)

Circulator flow rate / head graph

Flow rate (l/min)

Head

(kp

a)

Head

(kp

a)

80

70

60

50

40

30

20

10

0

8.16

7.14

6.12

5.10

4.08

3.06

2.04

1.02

00 200 400 600 800 1000 1200 1400 1600 1800 2000 2200

Flue System

Air inlet / flue outlet kitA wide range of original flue kits, guaranteed by Immergas, isavailable to solve different plant needs. They are manufactured instainless steel with seals in a special material to guarantee highresistance to corrosion and long life. The push-fit assemblyguarantees fast and easy installation. Many options with 45°/90°bends are available as well as extension pipes of 0,5 / 1 / 2 meters.

New shutter on the outlet flange In order to optimize the combustion efficiencyin relation to the length of the flue systeminstalled, a new outlet flange has beenconceived with a shutter system which,adequately regulated, avoids the use ofdiaphragms.

To correctly install boilers it is necessary to use theImmergas flue system in order to comply withstandards.

Room sealed EOLO models are equipped with sampling points for combustion analysis and can accommodate both con-centric and separate flue systems. It is easy to install, has good aesthetics and reduces the height.

TThhee bbooiilleerrss ooff nneeww MMaaiioorr kkWW rraannggee ccaann bbee aarrrraannggeedd wwiitthh DDIIMM ((MMuullttii--SSyysstteemm DDiissttrriibbuuttiioonn MMaanniiffoolldd)) aavvaaiillaabbllee iinn 44 fflluusshh--mmoouunnttiinngg kkiittssffoorr mmaannaaggiinngg ddiiffffeerreenntt zzoonnee ssyysstteemmss,, mmiixxeedd ssyysstteemmss aanndd ssyysstteemmss wwhhiicchh rreeqquuiirree aabbuunnddaanntt ssuuppppllyy ooff wwaatteerr..

Regulating by-pass:The by-pass can be adjusted simply by using a screwdriver.The regulation can be effected with a stroke of 3 turns.

Circulator flow rate / head graph

Flow rate (l/min)

Head

(kp

a)

Head

(kp

a)

80

70

60

50

40

30

20

10

0

8.16

7.14

6.12

5.10

4.08

3.06

2.04

1.02

00 200 400 600 800 1000 1200 1400 1600 1800 2000 2200

Available discharge head inthe system:

at maximum speed,by-pass excluded

at maximum speed,by-pass partially open(manufacturer setting)

at maximum speed,by-pass completelyopen

10

MMaaiioorr kkWW nneeww rraannggee

Nominal Heat InputMinimum Heat InputNominal Heat Output (useful)Minimum Heat Output (useful)Useful heating efficiency at 100% PnUseful heating efficiency at 30% of nominaloutputEnergy Efficiency (92/42 European Directive)Continuous service supply capacity with∆t 30° CMinimum pressure for sanitary hot waterMinimum hot water supplyAvailable head capacity 1000 l/hExpansion vessel capacity for heating circuit(effective volume of 7,4 litres)Weight of boiler full of water

Unit of NIKE Maior NIKE Maior EOLO Maior EOLO Maior EOLO MaiorTECHNICAL DATA measurement 24 kW 28 kW 24 kW 28 kW 32 kWN.G. VERSION CODE 3.015399 3.015401 3.015328 3.015330 3.015397LPG VERSION CODE 3.015399GPL 3.015401GPL 3.015328GPL 3.015330GPL 3.015397GPL

kW (kcal/h) 26,0 (22.387) 30,9 (26.574) 25,9 (22.241) 30,1 (25.923) 34,39 (29.579)kW (kcal/h) 10,7 (9.195) 12,0 (10.345) 10,7 (9.195) 12,2 (10.488) 14,42 (12.402)kW (kcal/h) 23,6 (20.300) 28,0 (24.040) 24,0 (20.640) 28,0 (24.080) 32,0 (27.520)kW (kcal/h) 9,3 (8.000) 10,5 (9.030) 9,3 (8.000) 10,5 (9.030) 12,5 (10.750)

% 90,7 90,7 92,8 92,9 93,0

% 89,7 89,80 90,7 90,9 91,5

Estrellas «« «« «« «« ««

Litros/Minuto 11,4 13,3 11,4 13,3 15,2

bar 0,3 0,3 0,3 0,3 0,3Litros/Minuto 2,0 2,0 2,0 2,0 2,0kPa (m H2O) 23,04 (2,35) 24,02 (2,45) 23,03 (2,35) 24,01 (2,45) 28,71 (2,93)

Litros 10* 10* 10* 10* 10*

kg 38 39,2 44 46,2 47,2

NNIIKKEE//EEOOLLOO MMaaiioorr kkWW

The data refer to a storage tank connected to NIKE/EOLOMaior kW X through the optional kit (code 3.015359)

Nominal Heat InputMinimum Heat InputNominal Heat Output (useful)Minimum Heat Output (useful)Useful heating efficiency at 100% PnUseful heating efficiency at 30% of nominaloutputEnergy Efficiency (92/42 European Directive)AISI 316L stainless steel storage tankcapacitySupply capacity with ∆t 30° C (max 10 minsupply of DHW)Continuous service supply capacity with ∆t 30° CDHW expansion vessel capacityAvailable head capacity 1000 l/hExpansion vessel capacity for heating circuit(effective volume of 7,4 litres)Weight of boiler full of water

Unit of NIKE Maior EOLO Maior UB 80 UB 105 UB 120 UB 200TECHNICAL DATA measurement 28 kW X 28 kW XN.G. VERSION CODE 3.015402 3.015400LPG VERSION CODE 3.015402GPL 3.015400GPLSTORAGE TANK CODE 3.011490 3.013317 3.011459 3.015356

kW (kcal/h) 30,9 (26.574) 30,1 (25.923)kW (kcal/h) 12,0 (10.345) 12,2 (10.488)kW (kcal/h) 28,0 (24.040) 28,0 (24.080)kW (kcal/h) 10,5 (9.030) 10,5 (9.030)

% 90,7 92,9

% 89,8 90,9

Estrellas «« «««

Litros 80 105 120 200

Litros/Minuto 20, 9 23,8 26,6 35,4

Litros/Minuto 13,3 13,3 13,3 13,3Litros 4 4 5 8

kPa (m H2O) 24,02 (2,45) 24,02 (2,45)

Litros 10* 10*

kg 39,2 46,2 141 171 200 273,5

NNIIKKEE//EEOOLLOO MMaaiioorr kkWW XX

EOLO Maior EOLO Maior24 kW Vip 28 kW Vip

3.015403 3.0153983.015403GPL 3.015398GPL25,9 (22.241) 30,1 (25.923)10,7 (9.195) 12,2 (10.488)24,0 (20.640) 28,0 (24.080)9,3 (8.000) 10,5 (9.030)

92,8 92,990,7 90,9««« «««

11,4 13,30,3 0,32,0 2,0

23,03 (2,35) 24,01 (2,45)

8** 8**

48 50,2

Nominal Heat InputMinimum Heat InputNominal Heat Output (useful)Minimum Heat Output (useful)Useful heating efficiency at 100% PnUseful heating efficiency at 30% of nominal outputEnergy Efficiency (92/42 European Directive)CONOxNOx classContinuous service supply capacity with ∆t 30° CMinimum pressure for sanitary hot waterMinimum hot water supplyAvailable head capacity 1000 l/hExpansion vessel capacity for heating circuit *(effectivevolume of 7,4 litres) **(effective volume of 6,5 litres)Weight of boiler full of water

Unit of EOLO Eco EOLO EcoTECHNICAL DATA measurement 24 kW 28 kW

N.G. VERSION CODE 3.015278 3.015280LPG VERSION CODE 3.015278GPL 3.015280GPL

kW (kcal/h) 25,8 (22.215) 30,1 (25.923)kW (kcal/h) 10,4 (8.975) 11,7 (10.090)kW (kcal/h) 24,0 (20.640) 28,0 (24.080)kW (kcal/h) 9,3 (8.000) 10,5 (9.030)

% 92,9 93,0% 92,4 92,0

Estrellas ««« «««

mg/kWh 32 31mg/kWh 40 26

5 5Litros/Minuto 11,4 13,3

bar 0,3 0,3Litros/Minuto 2,0 2,0

kPa (m H2O) 23,81 (2,43) 24,02 (2,45)

Litros 10* 10*

kg 44,5 46,7

EEOOLLOO EEccoo kkWW EEOOLLOO MMaaiioorr kkWW VViipp

11

MMaaiioorr kkWW nneeww rraannggee

177177

350

800

830

2010

220

350

800

830

201030

V

440

65 95 70

41

70 95

MRG

45

AC AF

Ø130

NIKE Maior kW NIKE/EOLO Maior kW – EOLO Maior kW Vip – EOLO Eco kW(instantaneous models with different output)

115 115105 105

30

V

440

65 95 70

41

70 95

MRG

45

AC AF

789

B A B

75

A

Concentric kit Ø 60/100

115

135

A B

Separator kit Ø 80/80

Gas supplyDomestic Hot Water outletDomestic Cold Water inletSystem returnSystem flowElectric connectionInlet / outletInlet

GACAFRMVAB

KEY:

Height (mm) Width (mm) Depth (mm)800 440 350

CONNECTIONS:

DOMESTIC WATER GAS SYSTEMC AC AF R M

1/2” 1/2” 1/2” 3/4” 3/4”

NIKE/EOLO Maior kW-EOLO Maior kW Vip-EOLO Eco kW (instantaneous models with different outputs)

NIKE Maior kW X EOLO Maior kW X

75

A

115

135

A B

220

350

800

830

2010

177177

350

800

830

2010

Ø130

30

V

440

65 95 70

41

MRG

45165

RR

115 115105 105

30

V

440

65 95 70

41

MRG

45

789

165

RR

B A B

Electric connectionGas supplyStorage tank returnStorage tank deliveryFilling systemSystem returnSystem flowInlet / outletInlet

VGRUMURRR MAB

KEY:

* only in the presence of connection kit to storage tank (code 3.015359)

Height (mm) Width (mm) Depth (mm)800 440 350

CONNECTIONS:

GAS DOMESTIC WATER WATER SYSTEMG RR MU*-RU* M-R

1/2” 1/2” 3/4” 3/4”

Concentric kit Ø 60/100

Separator kit Ø 80/80

NIKE/EOLO Maior kW X

12

Dimensions and connections

Storage Tank Capacity Height Width Depth

UB 80 (80 litres) 850 mm 500 mm 500 mm

UB 105 (105 litres) 1020 mm 500 mm 500 mm

UB 120 (120 litres) 850 mm 600 mm 600 mm

UB 200 (200 litres) 1250 mm 600 mm 600 mm

MMaaiioorr kkWW nneeww rraannggee

Indoor installation

Outdoor installation

Push-fitting vertical concentric kitø 80/125 with roof tile

Max length: 12,2 (**)

Push-fitting twin kit ø 80/80 Max length summing outlet and inlet pipes:

33,5 + 2 bends 90° (**)

Push-fitting horizontal kitMax length 3 m + 1 bend 90°

Horizontal fanassisted kit ø 80:Max length: 12 m (**)

Terminal outlet kit ø 80

Push-fitting horizontal kit ø 80/125Max length 7,3 m + 1 bend 90° (**)

Push-fitting twin kit ø 80/80 insulatedMax length summing outlet and inlet pipes:

33,5 + 2 bends 90° (**)

COD. 3.010352 COD. 3.010351 COD. 3.010350

COD. 3.010526COD. 3.010233

COD. 3.011488

COD. 3.011279

* the vertical terminal kit with roof-tile is available in 2 colours: (to be combined to the flanged stub-pipe ø 60/100 CODE 3.011141)white RAL9010 CODE 3.011698 / red ocher CODE 3.015631

* * for each “special” component fitted along the flue kit (like for example 45°/90° bends) the maximum length shown in the picturewill decrease of its “equivalent length”.

EOLO models are approved for outdoor installation inpartially protected places. They can work in two differentconfigurations:

1. Open flue Fan assisted boiler(B22 type)According to this configuration, the terminalflue outlet kit (B22 type) code 3.015388 iscompulsory together with one of the flue outletkits portrayed aside.

The distance between the outlet flange superior line andthe center line of the fan assisted horizontal bend kit ø 80is 175 mm (see instruction manual)

Room sealed fan assisted boiler (C type)The installation is possible using the whole range of air inlet / flue outlet kits portrayed in point 2.

2. Room sealed fan assisted boiler (C type)A wide range of flue kits is available for the installation, as portrayed below.

13

1

2

21

MMaaiioorr kkWW nneeww rraannggee

Options

14

KKiitt ddeessccrriippttiioonn

l l l l33..001111223366Amico Remote Control

CCooddee NNIIKKEE//EEOOLLOOMMaaiioorr kkWW

EEOOLLOO EEccookkWW

EEOOLLOO MMaaiioorrkkWW VViipp

NNIIKKEE//EEOOLLOOMMaaiioorr kkWW XX

l l l l33..001144008833External Sensor

l l l l33..001133330055

33..001155335500

33..001144443388

33..001111666688

33..44229977

33..001155885544

33..001111666677

Telephonic Control

l l standard lRelay Control Board

l l l l

33..001144443399 l l l l

Weekly DigitalChronothermostat

l l l lControl board forexternal pumps

l l l l

l l l l

Isolating valves

Isolating valves withfilter

l l l lUniversal connectionkit

Radio-chronothermostat(wireless)

MMaaiioorr kkWW nneeww rraannggee

15

KKiitt ddeessccrriippttiioonn

l l l33..001144994455Anti-scales kit

CCooddee NNIIKKEE//EEOOLLOOMMaaiioorr kkWW

EEOOLLOO EEccookkWW

EEOOLLOO MMaaiioorrkkWW VViipp

NNIIKKEE//EEOOLLOOMMaaiioorr kkWW XX

l33..001155445500

Additional expansionvessel (2 litres) forMaior Vip

l l l33..001155441133

33..001155335599

33..001155441111

33..001155441122

33..001155334488

Additional expansionvessel (2 litres) forMaior kW/X and EcokW

l

Connection kit toseparate storagetank

l

l33..001155334499Only Eoloversions

with C.A.R.

Only Eoloversions

with C.A.R.

Only Eoloversions

Only Eoloversions

Remote filling Vip

l l l lAnti-theft device

l lAnti-freeze kit(-15°C)

Remote filling(including relay controlboard)

Storage tank optional kits (to connect to NIKE/EOLO Maior kW X with optional kit 3.015359)

DHW recirculationsensor UB 80Cod 3.010347

DHW recirculationsensor UB 105Cod. 3.013363

DHW recirculationsensor UB 120Cod. 3.5115

DHW recirculationsensor UB 200Cod. 3.015274

Column connectionfor UB 105 andUB 200Cod. 3.014920

Solar PanelConnection kit forUB 200Cod. 3.015150

OOppttiioonnssMMaaiioorr kkWW nneeww rraannggee

The code of the template is 1.019861

NIKE/EOLO Maior kWEco-friendly wall-mounted combiand heating only system boilers

During the life of a boiler, performance is influenced by external factors, e.g. water hardness, atmospheric agents, systemliming, etc. The published data refers to new products correctly installed and used, in accordance with local regulations.

N.B. we recommend regular periodic maintenance of the appliance.

Immergas S.p.A. · 42041 Brescello (RE) Italy · Tel. +39.0522.689011 · Fax +39.0522.689178

www.immergas.com