Niobrara R&D Corp Niobrara R&D Corp SY/MAX PLC SY/MAX PLC Upgrades Upgrades With the SERI With the SERI

Upload: harriet-hines

Post on 17-Jan-2016

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Niobrara R&D Corp SY/MAX PLC Upgrades With the SERI

Niobrara R&D CorpNiobrara R&D Corp

SY/MAX PLCSY/MAX PLC

UpgradesUpgrades

With the SERIWith the SERI

Page 2: Niobrara R&D Corp SY/MAX PLC Upgrades With the SERI

Niobrara R&D CorpNiobrara R&D Corp

Technology-Driven Growth CompanyTechnology-Driven Growth Company Specializing in Data Communication ProductsSpecializing in Data Communication Products Complete design/manufacturing facilitiesComplete design/manufacturing facilities

Founded 1987Founded 1987 Joplin, Missouri USAJoplin, Missouri USA

Products Distributed WorldwideProducts Distributed Worldwide Through Schneider Electric ChannelsThrough Schneider Electric Channels

Page 3: Niobrara R&D Corp SY/MAX PLC Upgrades With the SERI

SY/MAX Upgrades:SY/MAX Upgrades:SERI-TSERI-T

Replace SY/MAX PLCReplace SY/MAX PLC– Single width moduleSingle width module– Mount in Slot 1Mount in Slot 1– Works in RRK and HRK Works in RRK and HRK

racksracks– 10BaseT Ethernet Port10BaseT Ethernet Port

Ethernet Distributed Ethernet Distributed I/O from any I/O from any Modbus/TCP MasterModbus/TCP Master– Quantum I/O ScannerQuantum I/O Scanner– M340 NOE I/O ScannerM340 NOE I/O Scanner– Premium I/O ScannerPremium I/O Scanner– Momentum I/O ScannerMomentum I/O Scanner

Page 4: Niobrara R&D Corp SY/MAX PLC Upgrades With the SERI

SERI (continued)SERI (continued)

Front Panel Key SwitchFront Panel Key Switch RS-485 Serial portRS-485 Serial port

– Used for Firmware Upgrades, Used for Firmware Upgrades, configuration, configuration, troubleshootingtroubleshooting

– SY/MAX pinoutSY/MAX pinout– Modbus RTU SlaveModbus RTU Slave– May be used for rack controlMay be used for rack control

IndicatorsIndicators– Power, Run, Program, Power, Run, Program,

Memory,Outputs Disabled, Memory,Outputs Disabled, I/O Error, Config ErrorI/O Error, Config Error

– Serial port TX & RXSerial port TX & RX– Ethernet port Link, Col, TX & Ethernet port Link, Col, TX &

RX, and ErrorRX, and Error

Page 5: Niobrara R&D Corp SY/MAX PLC Upgrades With the SERI

Rack MapperRack Mapper

10,000 words of Holding Registers (4x) 10,000 words of Holding Registers (4x) – Accessed as Modbus/TCP Index 0 or 1Accessed as Modbus/TCP Index 0 or 1– Accepts Modbus/TCP function codes 3, 6, 16, and 23Accepts Modbus/TCP function codes 3, 6, 16, and 23

Mapper associates these Holding Registers Mapper associates these Holding Registers to Inputs and Outputs on the rack. to Inputs and Outputs on the rack. – Group all of the Inputs together (and Outputs) so a Group all of the Inputs together (and Outputs) so a

single I/O Scanner entry covers the entire SERIsingle I/O Scanner entry covers the entire SERI– Internal SERI configuration and status registers may Internal SERI configuration and status registers may

also be mapped to the I/O registersalso be mapped to the I/O registers– Each Output word has a default value on watchdog Each Output word has a default value on watchdog

failurefailure– HRK 8-bit modules are mapped as a single word (LSB)HRK 8-bit modules are mapped as a single word (LSB)– Mapper can reverse bit order for 984 logic alignmentMapper can reverse bit order for 984 logic alignment

Page 6: Niobrara R&D Corp SY/MAX PLC Upgrades With the SERI

Main Main page page view view with an with an I/O I/O ErrorError

Page 7: Niobrara R&D Corp SY/MAX PLC Upgrades With the SERI

Slot Slot view view page page showinshowing g values values and and statusstatus

Page 8: Niobrara R&D Corp SY/MAX PLC Upgrades With the SERI

Comms Comms page page showing showing IP IP settings, settings, Masters, Masters, and and WatchdoWatchdogg

Page 9: Niobrara R&D Corp SY/MAX PLC Upgrades With the SERI

Change Rack Change Rack page page

SERI detects SERI detects the actual the actual rack type rack type and gives a and gives a configuratioconfiguration fault on n fault on mismatchmismatch

Page 10: Niobrara R&D Corp SY/MAX PLC Upgrades With the SERI
Page 11: Niobrara R&D Corp SY/MAX PLC Upgrades With the SERI

Niobrara R & D Niobrara R & D CorpCorp