C20 Converged Softswitch Logs and Alarms Reference, Volume 10 Release: CVM16 and up Document Revision: 12.01 www.genband.com NN10275-909v10

Upload: davinpuurunen

Post on 27-Oct-2015

124 views

Category:

Documents


15 download

TRANSCRIPT

Page 1: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

C20 Converged Softswitch

Logs and Alarms Reference,Volume 10Release: CVM16 and upDocument Revision: 12.01

www.genband.com

NN10275-909v10

Page 2: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

C20 Converged SoftswitchRelease: CVM16 and upPublication: NN10275-909v10Document status: StandardDocument release date: 03 October 2011

Copyright © 2011 GENBAND. All rights reserved. Use of this documentation and its contents is subject to theterms and conditions of the applicable end user or software license agreement, right to use notice, and all relevantcopyright protections.

GENBAND, the GENBAND corporate logo and tagline, and certain of GENBAND's product and solution namesare registered trademarks of GENBAND and its affiliates.

While the information in this document is believed to be accurate and reliable, except as otherwise expresslyagreed to in writing GENBAND AND/OR ITS LICENSORS PROVIDES THIS DOCUMENT "AS IS" WITHOUTWARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or productsdescribed in this document are subject to change without notice.

THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF GENBAND OR ITS LICENSORS ANDMUST NOT BE DISCLOSED, OTHER THAN TO EMPLOYEES OF GENBAND OR CUSTOMERS WITH NEED-TO-KNOW, WITHOUT THE PRIOR WRITTEN CONSENT OF GENBAND OR ITS LICENSORS. THEINFORMATION MUST NOT BE DISCLOSED TO SUBCONTRACTORS OR REGULATORY AUTHORITIES. GENBAND MUST BE NOTIFIED OF ANY REQUEST OR ORDER FOR DISCLOSURE PRIOR TO SUCHDISCLOSURE.

Software and documentation owned by or under license with Nortel Networks included in this Release or in anydocument provided with this Release is Copyright © 2010 Nortel Networks or its licensors. All rights reserved. Useof this software and/or documentation and its contents is subject to the terms and conditions of the applicable enduser or software license agreement, right to use notice, and all relevant copyright protections. The product names remain as Carrier VoIP and CS 2000 in Canada and France pending regulatory approvals for a name change.

Page 3: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Contents

New in this release 37DMS_ACDtoAUD 37

Logs and alarms fundamentals 39

DMS_ACDtoAUD alarms and logs reference 41ACD110 41

Remedial action 41Attributes 41Format 41Selected field descriptions 42Active message example 42Clear message example 42Associated OM registers 43

ACD121 43Remedial action 43Attributes 43Format 43Selected field descriptions 43Active message example 43Clear message example 44Associated OM registers 44

ACD130 44Remedial action 44Attributes 44Format 44Selected field descriptions 44Active message example 45Clear message example 45Associated OM registers 45

ACMS100-Canada only 45Remedial action 45Attributes 45Format 46Selected field descriptions 46Active message example 47Clear message example 48Associated OM registers 48

ACMS101-Canada only 48

3

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 4: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial action 48Attributes 48Format 48Selected field descriptions 49Active message example 50Clear message example 51Associated OM registers 51

ACMS102-Canada only 51Remedial action 51Attributes 51Format 51Selected field descriptions 52Active message example 53Clear message example 53Associated OM registers 54

ACMS103-Canada only 54Remedial action 54Attributes 54Format 54Selected field descriptions 55Active message example 56Clear message example 56Associated OM registers 56

ACMS104-Canada only 56Remedial action 57Attributes 57Format 57Selected field descriptions 58Active message example 59Clear message example 60Associated OM registers 60

ACMS105-Canada only 60Remedial action 60Attributes 61Format 61Selected field descriptions 61Active message example 61Clear message example 62Associated OM registers 62

ACT100 62Remedial action 62Attributes 62Format 62Selected field descriptions 63Active message example 64Clear message example 64Associated OM registers 64

ACT101 64Remedial action 65Attributes 65

4

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 5: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Format 65Selected field descriptions 65Active message example 65Clear message example 65Associated OM registers 65

ACT102 65Remedial action 66Attributes 66Format 66Selected field descriptions 66Active message example 68Clear message example 68Associated OM registers 68

AFT003 68Remedial action 68Attributes 68Format 68Selected field descriptions 69Active message example 69Clear message example 69Associated OM registers 69

AIN300 69Remedial action 70Attributes 70Format 70Selected field descriptions 71Active message example 71Clear message example 71Associated OM registers 71

AIN301 71Remedial action 72Attributes 72Format 72Selected field descriptions 72Active message example 73Clear message example 73Associated OM registers 73

AIN302 73Remedial action 73Attributes 74Format 74Selected field descriptions 74Active message example 74Clear message example 75Associated OM registers 75

AIN303 75Remedial action 75Attributes 75Format 75Selected field descriptions 76

5

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 6: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message example 76Clear message example 76Associated OM registers 76

AIN304 76Remedial action 76Attributes 76Format 77Selected field descriptions 77Active message example 77Clear message example 77Associated OM registers 77

AIN500 77Remedial action 78Attributes 78Format 78Selected field descriptions 78Active message example 79Clear message example 79Associated OM registers 79

AIN501 79Remedial action 79Attributes 80Format 80Selected field descriptions 80Active message example 80Clear message example 81Associated OM registers 81

AIN510 81Remedial action 81Attributes 81Format 81Selected field descriptions 82Active message example 82Clear message example 82Associated OM registers 82

AIN511 82Remedial action 82Attributes 82Format 82Selected field descriptions 83Active message example 83Clear message example 83Associated OM registers 83

AIN600 83Remedial action 83Attributes 83Format 83Selected field descriptions 84Active message example 85Clear message example 85

6

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 7: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers 85AIN601 85

Remedial action 85Attributes 86Format 86Selected field descriptions 86Active message example 87Clear message example 88Associated OM registers 88

AIN602 88Remedial action 88Attributes 88Format 88Selected field descriptions 89Active message example 89Clear message example 90Associated OM registers 90

AIN610 90Remedial action 90Attributes 90Format 90Selected field descriptions 91Active message example 91Clear message example 92Associated OM registers 92

AIN611 92Remedial action 92Attributes 92Format 92Selected field descriptions 93Active message example 93Clear message example 93Associated OM registers 93

AIN612 93Remedial action 94Attributes 94Format 94Selected field descriptions 94Active message example 94Clear message example 95Associated OM registers 95

AINT700 Format 1 95Remedial action 95Attributes 96Format 96Selected field descriptions 96Active message example 97Clear message example 100Associated OM registers 100

AINT700 Format 2 100

7

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 8: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial action 100Attributes 100Format 100Selected field descriptions 101Active message example 102Clear message example 109Associated OM registers 109

AINT700 Format 3 109Remedial action 109Attributes 109Format 109Selected field descriptions 110Active message example 111Clear message example 123Associated OM registers 123

ALRM109 123Remedial action 123Attributes 123Format 123Selected field descriptions 124Active message example 124Clear message example 124Associated OM registers 125

ALRM111 125Remedial action 125Attributes 125Format 125Selected field descriptions 125Active message example 125Clear message example 125Associated OM registers 126

ALRM112 126Remedial action 126Attributes 126Format 126Selected field descriptions 126Active message example 126Clear message example 126Associated OM registers 127

ALT100 127Remedial action 127Attributes 127Format 127Selected field descriptions 127Active message example 128Clear message example 128Associated OM registers 128

ALT101 128Remedial action 153Attributes 154

8

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 9: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Format 154Selected field descriptions 154Active message example 155Clear message example 156Associated OM registers 156

ALT103 156Remedial action 156Attributes 157Format 157Selected field descriptions 157Active message example 158Clear message example 159Associated OM registers 159

ALT104 159Remedial action 159Attributes 159Format 160Selected field descriptions 160Active message example 161Clear message example 161Associated OM registers 161

ALT105 161Remedial action 162Attributes 162Format 162Selected field descriptions 162Active message example 163Clear message example 163Associated OM registers 163

ALT106 163Remedial action 164Attributes 164Format 164Selected field descriptions 164Active message example 165Clear message example 165Associated OM registers 166

ALT107 166Remedial action 169Attributes 169Format 169Selected field descriptions 170Active message example 170Clear message example 170Associated OM registers 171

ALT108 171Remedial action 171Attributes 171Format 171Selected field descriptions 171

9

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 10: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message example 172Clear message example 172Associated OM registers 172

ALT109 172Remedial action 172Attributes 173Format 173Selected field descriptions 174Active message example 176Clear message example 176Associated OM registers 176

ALT110 176Remedial action 177Attributes 177Format 177Selected field descriptions 177Active message example 177Clear message example 178Associated OM registers 178

ALT111 178Remedial action 178Attributes 178Format 178Selected field descriptions 179Active message example 179Clear message example 179Associated OM registers 179

ALT112 179Remedial action 180Attributes 180Format 180Selected field descriptions 180Active message example 180Clear message example 182Associated OM registers 182

ALT113 182Remedial action 182Attributes 182Format 182Selected field descriptions 182Active message example 182Clear message example 183Associated OM registers 184

ALT200 184Remedial action 185Attributes 185Format 185Selected field descriptions 185Active message example 186Clear message example 186

10

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 11: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers 186ALT209 186

Remedial action 188Attributes 188Format 188Selected field descriptions 189Active message example 190Clear message example 191Associated OM registers 191

ALT300 191Remedial action 192Attributes 192Format 192Selected field descriptions 193Active message example 193Clear message example 193Associated OM registers 194

ALT306 194Remedial action 194Attributes 194Format 194Selected field descriptions 195Active message example 195Clear message example 196Associated OM registers 196

ALT307 196Remedial action 197Attributes 197Format 197Selected field descriptions 198Active message example 198Clear message example 198Associated OM registers 199

ALT308 199Remedial action 199Attributes 199Format 199Selected field descriptions 200Active message example 201Clear message example 201Associated OM registers 202

ALT309 202Remedial action 203Attributes 203Format 203Selected field descriptions 205Active message example 205Clear message example 206Associated OM registers 206

AMA100 206

11

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 12: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial action 206Attributes 207Format 207Selected field descriptions 207Active message example 207Clear message example 208Associated OM registers 208

AMA112 208Remedial action 208Attributes 208Format 208Selected field descriptions 209Active message example 209Clear message example 209Associated OM registers 210

AMA114 210Remedial action 210Attributes 210Format 210Selected field descriptions 210Active message example 211Clear message example 211Associated OM registers 211

AMA117 211Remedial action 211Attributes 212Format 212Selected field descriptions 212Active message example 213Clear message example 213Associated OM registers 214

AMA118 214Remedial action 214Attributes 214Format 214Selected field descriptions 214Active message example 214Clear message example 217Associated OM registers 217

AMAB100 217Remedial action 219Attributes 219Format 220Selected field descriptions 220Active message example 221Clear message example 221Associated OM registers 221

AMAB101 221Remedial action 221Attributes 221

12

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 13: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Format 221Selected field descriptions 222Active message example 223Clear message example 223Associated OM registers 223

AMAB102 223Remedial action 223Attributes 223Format 223Selected field descriptions 224Active message example 227Clear message example 227Associated OM registers 227

AMAB103 227Remedial action 227Attributes 227Format 227Selected field descriptions 227Active message example 228Clear message example 228Associated OM registers 228

AMAB104 228Remedial action 228Attributes 229Format 229Selected field descriptions 229Active message example 229Clear message example 229Associated OM registers 229

AMAB105 229Remedial action 230Attributes 230Format 230Selected field descriptions 230Active message example 230Clear message example 230Associated OM registers 231

AMAB106 231Remedial action 231Attributes 231Format 231Selected field descriptions 231Active message example 232Clear message example 232Associated OM registers 232

AMAB108 232Remedial action 233Attributes 234Format 234Selected field descriptions 234

13

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 14: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message example 235Clear message example 235Associated OM registers 235

AMAB109 235Remedial action 235Attributes 235Format 236Selected field descriptions 236Active message example 236Clear message example 237Associated OM registers 237

AMAB110 237Remedial action 237Attributes 237Format 237Selected field descriptions 237Active message example 237Clear message example 237Associated OM registers 238

AMAB111 238Remedial action 238Attributes 238Format 238Selected field descriptions 238Active message example 241Clear message example 241Associated OM registers 241

AMAB115 241Remedial action 242Attributes 242Format 242Selected field descriptions 242Active message example 242Clear message example 242Associated OM registers 242

AMAB118 242Remedial action 243Attributes 244Format 244Selected field descriptions 244Active message example 245Clear message example 245Associated OM registers 245

AMAB119 245Remedial action 245Attributes 245Format 245Selected field descriptions 246Active message example 247Clear message example 247

14

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 15: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers 248AMAB122 248

Remedial action 248Attributes 248Format 248Selected field descriptions 248Active message example 250Clear message example 250Associated OM registers 251

AMAB150 251Remedial action 251Attributes 251Format 251Selected field descriptions 252Active message example 256Clear message example 256Associated OM registers 256

AMAB151 256Remedial action 258Attributes 258Format 258Selected field descriptions 258Active message example 258Clear message example 258Associated OM registers 258

AMAB153 258Remedial action 259Attributes 259Format 259Selected field descriptions 259Active message example 260Clear message example 260Associated OM registers 260

AMAB154 260Remedial action 260Attributes 260Format 261Selected field descriptions 261Active message example 261Clear message example 261Associated OM registers 261

AMAB155 261Remedial action 262Attributes 262Format 262Selected field descriptions 262Active message example 265Clear message example 266Associated OM registers 266

AMAB160 266

15

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 16: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial action 266Attributes 266Format 266Selected field descriptions 267Active message example 269Clear message example 269Associated OM registers 269

AMAB161 269Remedial action 269Attributes 269Format 269Selected field descriptions 270Active message example 270Clear message example 270Associated OM registers 270

AMAB180 270Remedial action 273Attributes 273Format 273Selected field descriptions 273Active message example 276Clear message example 276Associated OM registers 276

AMAB181 276Remedial action 276Attributes 277Format 277Selected field descriptions 277Active message example 277Clear message example 277Associated OM registers 278

AMAB182 278Remedial action 278Attributes 278Format 278Selected field descriptions 278Active message example 278Clear message example 279Associated OM registers 279

AMAB183 279Remedial action 279Attributes 279Format 279Selected field descriptions 279Active message example 279Clear message example 280Associated OM registers 280

AMAB184 280Remedial action 280Attributes 280

16

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 17: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Format 280Selected field descriptions 281Active message example 281Clear message example 281Associated OM registers 281

AMAB185 281Remedial action 282Attributes 282Format 282Selected field descriptions 282Active message example 283Clear message example 283Associated OM registers 283

AMAB186 283Remedial action 283Attributes 283Format 283Selected field descriptions 284Active message example 284Clear message example 284Associated OM registers 284

AMAB187 284Remedial action 284Attributes 284Format 284Selected field descriptions 285Active message example 285Clear message example 285Associated OM registers 286

AMAB189 286Remedial action 286Attributes 286Format 286Selected field descriptions 287Active message example 287Clear message example 287Associated OM registers 287

AMAB200 287Remedial action 288Attributes 288Format 288Selected field descriptions 288Active message example 289Clear message example 289Associated OM registers 290

AOSS100 290Remedial action 290Attributes 290Format 290Selected field descriptions 290

17

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 18: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message example 291Clear message example 291Associated OM registers 291

AOSS101 291Remedial action 291Attributes 291Format 292Selected field descriptions 292Active message example 292Clear message example 293Associated OM registers 293

AOSS102 293Remedial action 293Attributes 293Format 293Selected field descriptions 293Active message example 294Clear message example 294Associated OM registers 294

AOSS103 294Remedial action 294Attributes 294Format 294Selected field descriptions 295Active message example 295Clear message example 296Associated OM registers 296

AOSS105 296Remedial action 296Attributes 296Format 296Selected field descriptions 296Active message example 297Clear message example 297Associated OM registers 297

AOSS107 297Remedial action 297Attributes 298Format 298Selected field descriptions 298Active message example 298Clear message example 299Associated OM registers 299

AOSS108 299Remedial action 299Attributes 299Format 299Selected field descriptions 299Active message example 300Clear message example 300

18

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 19: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers 300AP310 300

Remedial action 300Attributes 300Format 301Selected field descriptions 301Active message example 302Clear message example 302Associated OM registers 302

AP311 302Remedial action 303Attributes 303Format 303Selected field descriptions 303Active message example 304Clear message example 304Associated OM registers 305

AP313 305Remedial action 305Attributes 305Format 305Selected field descriptions 305Active message example 306Clear message example 306Associated OM registers 306

AP314 306Remedial action 307Attributes 307Format 307Selected field descriptions 307Active message example 308Clear message example 308Associated OM registers 308

AP315 308Remedial action 308Attributes 308Format 309Selected field descriptions 309Active message example 309Clear message example 310Associated OM registers 310

AP316 310Remedial action 310Attributes 310Format 310Selected field descriptions 311Active message example 311Clear message example 311Associated OM registers 311

AP319 311

19

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 20: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial action 312Attributes 312Format 312Selected field descriptions 312Active message example 313Clear message example 313Associated OM registers 313

AP320 313Remedial action 313Attributes 314Format 314Selected field descriptions 314Active message example 314Clear message example 315Associated OM registers 315

AP321 315Remedial action 315Attributes 315Format 315Selected field descriptions 316Active message example 316Clear message example 316Associated OM registers 316

AP322 316Remedial action 317Attributes 317Format 317Selected field descriptions 317Active message example 318Clear message example 318Associated OM registers 318

AP323 318Remedial action 319Attributes 319Format 319Selected field descriptions 320Active message example 321Clear message example 321Associated OM registers 321

AP324 321Remedial action 321Attributes 321Format 321Selected field descriptions 322Active message example 322Clear message example 323Associated OM registers 323

AP401 323Remedial action 323Attributes 323

20

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 21: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Format 323Selected field descriptions 324Active message example 324Clear message example 324Associated OM registers 324

AP450 324Remedial action 325Attributes 325Format 325Selected field descriptions 326Active message example 326Clear message example 326Associated OM registers 326

AP450 Format 2 326Remedial action 327Attributes 327Format 327Selected field descriptions 328Active message example 328Clear message example 329Associated OM registers 329

AP451 329Remedial action 329Attributes 329Format 329Selected field descriptions 330Active message example 330Clear message example 331Associated OM registers 331

AP501 331Remedial action 331Attributes 331Format 331Selected field descriptions 331Active message example 332Clear message example 332Associated OM registers 332

AP502 332Remedial action 333Attributes 333Format 333Selected field descriptions 334Active message example 335Clear message example 335Associated OM registers 336

AP503 336Remedial action 336Attributes 336Format 336Selected field descriptions 336

21

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 22: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message example 337Clear message example 337Associated OM registers 337

AP504 337Remedial action 337Attributes 337Format 337Selected field descriptions 338Active message example 338Clear message example 339Associated OM registers 339

AP800 339Remedial action 339Attributes 339Format 339Selected field descriptions 339Active message example 339Clear message example 340Associated OM registers 340

APS100-121 340Remedial action 340Attributes 341Format 341Selected field descriptions 341Active message example 343Clear message example 343Associated OM registers 343

ARN600 343Remedial action 344Attributes 344Format 344Selected field descriptions 344Active message example 345Clear message example 345Associated OM registers 345

ARN601 345Remedial action 345Attributes 345Format 345Selected field descriptions 346Active message example 346Clear message example 346Associated OM registers 346

ATB100 346Remedial action 347Attributes 347Format 347Selected field descriptions 347Active message example 347Clear message example 347

22

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 23: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers 348ATM301 348

Remedial action 348Attributes 348Format 348Selected field descriptions 348Active message example 349Clear message example 349Associated OM registers 349

ATM500 349Remedial action 350Attributes 350Format 350Selected field descriptions 350Active message example 351Clear message example 351Associated OM registers 351

ATM601 351Remedial action 351Attributes 351Format 352Selected field descriptions 352Active message example 352Clear message example 353Associated OM registers 353

ATM604 353Remedial action 353Attributes 353Format 353Selected field descriptions 353Active message example 354Clear message example 354Associated OM registers 354

ATM606 354Remedial action 355Attributes 355Format 355Selected field descriptions 355Active message example 356Clear message example 357Associated OM registers 357

ATME200 357Remedial action 357Attributes 357Format 357Selected field descriptions 358Active message example 360Clear message example 360Associated OM registers 360

ATME201 360

23

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 24: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial action 361Attributes 361Format 361Selected field descriptions 361Active message example 364Clear message example 364Associated OM registers 365

ATME202 365Remedial action 365Attributes 365Format 365Selected field descriptions 365Active message example 368Clear message example 368Associated OM registers 368

ATME203 368Remedial action 369Attributes 369Format 369Selected field descriptions 369Active message example 372Clear message example 372Associated OM registers 372

ATME204 372Remedial action 372Attributes 373Format 373Selected field descriptions 373Active message example 376Clear message example 376Associated OM registers 376

ATME205 376Remedial action 376Attributes 377Format 377Selected field descriptions 377Active message example 380Clear message example 380Associated OM registers 380

ATME206 380Remedial action 380Attributes 380Format 380Selected field descriptions 381Active message example 383Clear message example 384Associated OM registers 384

ATME207 384Remedial action 384Attributes 384

24

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 25: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Format 384Selected field descriptions 385Active message example 387Clear message example 388Associated OM registers 388

ATME208 388Remedial action 388Attributes 388Format 388Selected field descriptions 389Active message example 391Clear message example 392Associated OM registers 392

ATT100 392Remedial action 392Attributes 392Format 392Selected field descriptions 392Active message example 393Clear message example 393Associated OM registers 393

ATT101 393Remedial action 393Attributes 394Format 394Selected field descriptions 394Active message example 411Clear message example 411Associated OM registers 411

ATT102 411Remedial action 411Attributes 411Format 411Selected field descriptions 412Active message example 428Clear message example 429Associated OM registers 429

ATT103 429Remedial action 429Attributes 430Format 430Selected field descriptions 430Active message example 447Clear message example 447Associated OM registers 447

ATT104 447Remedial action 448Attributes 448Format 448Selected field descriptions 448

25

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 26: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message example 449Clear message example 449Associated OM registers 450

ATT105 450Remedial action 450Attributes 450Format 450Selected field descriptions 451Active message example 452Clear message example 452Associated OM registers 452

ATT106 452Remedial action 452Attributes 453Format 453Selected field descriptions 453Active message example 454Clear message example 454Associated OM registers 454

ATT107 454Remedial action 455Attributes 455Format 455Selected field descriptions 455Active message example 457Clear message example 457Associated OM registers 457

ATT108 457Remedial action 458Attributes 458Format 458Selected field descriptions 459Active message example 460Clear message example 460Associated OM registers 460

ATT109 460Remedial action 460Attributes 461Format 461Selected field descriptions 461Active message example 473Clear message example 473Associated OM registers 474

ATT110 474Remedial action 476Attributes 476Format 476Selected field descriptions 477Active message example 485Clear message example 486

26

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 27: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers 487ATT111 487

Remedial action 487Attributes 487Format 487Selected field descriptions 487Active message example 487Clear message example 487Associated OM registers 488

ATT112 488Remedial action 488Attributes 488Format 488Selected field descriptions 488Active message example 489Clear message example 489Associated OM registers 489

ATT113 489Remedial action 490Attributes 490Format 490Selected field descriptions 491Active message example 491Clear message example 492Associated OM registers 492

ATT113 Format 2 492Remedial action 493Attributes 493Format 493Selected field descriptions 494Active message example 494Clear message example 495Associated OM registers 495

ATT113 Format 3 495Remedial action 496Attributes 496Format 496Selected field descriptions 497Active message example 497Clear message example 497Associated OM registers 497

ATT113 Format 4 497Remedial action 498Attributes 499Format 499Selected field descriptions 499Active message example 499Clear message example 499Associated OM registers 500

ATT113 Format 5 500

27

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 28: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial action 501Attributes 501Format 501Selected field descriptions 501Active message example 502Clear message example 502Associated OM registers 502

ATT113 Format 6 502Remedial action 503Attributes 503Format 503Selected field descriptions 504Active message example 504Clear message example 504Associated OM registers 505

ATT113 Format 7 505Remedial action 506Attributes 506Format 506Selected field descriptions 506Active message example 507Clear message example 507Associated OM registers 507

ATT114 507Remedial action 507Attributes 507Format 507Selected field descriptions 508Active message example 516Clear message example 516Associated OM registers 516

ATT115 516Remedial action 516Attributes 517Format 517Selected field descriptions 517Active message example 518Clear message example 519Associated OM registers 519

ATT116 519Remedial action 519Attributes 520Format 520Selected field descriptions 520Active message example 521Clear message example 522Associated OM registers 522

ATT117 522Remedial action 522Attributes 522

28

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 29: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Format 522Selected field descriptions 523Active message example 523Clear message example 523Associated OM registers 524

ATT118 524Remedial action 524Attributes 524Format 524Selected field descriptions 525Active message example 526Clear message example 526Associated OM registers 526

ATT119 526Remedial action 526Attributes 526Format 526Selected field descriptions 527Active message example 527Clear message example 527Associated OM registers 527

ATT120 527Remedial action 527Attributes 527Format 527Active message example 527Clear message example 528Associated OM registers 528

ATT121 528Remedial action 528Attributes 528Format 528Selected field descriptions 528Active message example 529Clear message example 529Associated OM registers 529

ATT122 529Remedial action 529Attributes 530Format 530Selected field descriptions 530Active message example 530Clear message example 530Associated OM registers 530

ATT123 530Remedial action 531Attributes 531Format 531Selected field descriptions 531Active message example 533

29

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 30: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message example 533Associated OM registers 533

ATT124 533Remedial action 534Attributes 534Format 534Selected field descriptions 534Active message example 534Clear message example 534Associated OM registers 534

AUD101 534Remedial action 534Attributes 535Format 535Selected field descriptions 535Active message example 535Clear message example 536Associated OM registers 536

AUD102 536Remedial action 536Attributes 536Format 536Selected field descriptions 536Active message example 536Clear message example 536Associated OM registers 537

AUD103 537Remedial action 537Attributes 537Format 537Selected field descriptions 537Active message example 538Clear message example 538Associated OM registers 538

AUD104 538Remedial action 538Attributes 538Format 538Selected field descriptions 538Active message example 539Clear message example 539Associated OM registers 539

AUD105 539Remedial action 540Attributes 540Format 540Selected field descriptions 540Active message example 541Clear message example 541Associated OM registers 541

30

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 31: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AUD106 541Remedial action 542Attributes 542Format 542Selected field descriptions 542Active message example 543Clear message example 543Associated OM registers 543

AUD107 543Remedial action 544Attributes 544Format 544Selected field descriptions 544Active message example 544Clear message example 545Associated OM registers 545

AUD108 545Remedial action 545Attributes 545Format 545Selected field descriptions 546Active message example 547Clear message example 547Associated OM registers 547

AUD120 547Remedial action 547Attributes 547Format 547Selected field descriptions 548Active message example 548Clear message example 548Associated OM registers 548

AUD394 548Remedial action 552Attributes 553Format 553Selected field descriptions 553Active message example 553Clear message example 554Associated OM registers 554

AUD395 554Remedial action 556Attributes 556Format 556Selected field descriptions 556Active message example 557Clear message example 557Associated OM registers 557

AUD396 557Remedial action 558

31

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 32: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Attributes 558Format 558Selected field descriptions 558Active message example 560Clear message example 560Associated OM registers 560

AUD398 560Remedial action 562Attributes 563Format 563Selected field descriptions 563Active message example 563Clear message example 563Associated OM registers 564

AUD399 564Remedial action 564Attributes 564Format 564Selected field descriptions 565Active message example 565Clear message example 566Associated OM registers 566

AUD400 566Remedial action 566Attributes 567Format 567Selected field descriptions 567Active message example 567Clear message example 567Associated OM registers 567

AUD401 567Remedial action 568Attributes 568Format 568Selected field descriptions 569Active message example 569Clear message example 569Associated OM registers 569

AUD402 569Remedial action 570Attributes 571Format 571Selected field descriptions 571Active message example 571Clear message example 571

AUD403 571Remedial action 572Attributes 572Format 573Selected field descriptions 573

32

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 33: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message example 573Clear message example 573Associated OM registers 573

AUD404 573Remedial action 574Attributes 574Format 575Selected field descriptions 575Active message example 575Clear message example 575Associated OM registers 576

AUD405 576Remedial action 576Attributes 577Format 577Selected field descriptions 577Active message example 577Clear message example 578Associated OM registers 578

AUD406 578Remedial action 578Attributes 579Format 579Selected field descriptions 579Active message example 579Clear message example 580Associated OM registers 580

AUD407 580Remedial action 581Attributes 582Format 582Selected field descriptions 582Active message example 582Clear message example 582Associated OM registers 583

AUD408 583Remedial action 583Attributes 584Format 584Selected field descriptions 584Active message example 584Clear message example 584Associated OM registers 584

AUD409 584Remedial action 585Attributes 586Format 586Selected field descriptions 586Active message example 586Clear message example 586

33

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 34: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers 587AUD410 587

Remedial action 587Attributes 588Format 588Selected field descriptions 588Active message example 588Clear message example 589Associated OM registers 589

AUD411 589Remedial action 589Attributes 590Format 590Selected field descriptions 590Active message example 591Clear message example 591Associated OM registers 591

AUD412 591Remedial action 591Attributes 592Format 592Selected field descriptions 593Active message example 593Clear message example 593Associated OM registers 593

AUD413 593Remedial action 593Attributes 594Format 594Selected field descriptions 594Active message example 594Clear message example 595Associated OM registers 595

AUD414 595Remedial action 595Attributes 596Format 596Selected field descriptions 597Active message example 597Clear message example 597Associated OM registers 597

AUD416 597Remedial action 597Attributes 599Format 599Selected field descriptions 599Active message example 599Clear message example 600Associated OM registers 600

AUD417 600

34

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 35: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial action 600Attributes 601Format 601Selected field descriptions 601Active message example 601Clear message example 602Associated OM registers 602

AUD418 602Remedial action 602Attributes 603Format 603Selected field descriptions 603Active message example 603Clear message example 604Associated OM registers 604

AUD419 604Remedial action 604Attributes 605Format 605Selected field descriptions 605Active message example 605Clear message example 606Associated OM registers 606

AUD420 606Remedial action 606Attributes 607Format 607Selected field descriptions 607Active message example 607Associated OM registers 608

35

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 36: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

36

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 37: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

New in this release

The following sections detail what's new in the following network elementsand applications for the CORE13 release.

DMS_ACDtoAUDNo Changes for this device

37

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 38: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

38 New in this release

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 39: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Logs and alarms fundamentals

A log report is a message about an important conditions or events relatedto component(s) performance. Log reports include, but are not restrictedto, the following information:

• state and activity reports

• changes in state

• hardware or software errors

• test results

• other events or conditions that affect performance

Both system actions and manual overrides can generate log reports.

Attention: This document uses multiple volumes to describe logs thatthe C20 network components can generate. Not all components apply toevery solution.

Attention: In systems which include an Integrated ElementManagement System (IEMS), clearing of manually clearable alarmsthrough OMI (or a System Management GUI) is reflected in the IEMS.However, acknowledgement of alarms through OMI (or a SystemManagement GUI) is NOT reflected in the IEMS.

39

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 40: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

40 Logs and alarms fundamentals

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 41: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

DMS_ACDtoAUD alarms and logsreference

This section provides a reference for the DMS_ACDtoAUD alarms andlogs for the CORE13 release.

ACD110The automatic call distribution (ACD) subsystem generates ACD110. Thisreport appears when a computed link is in a queue or when the ACD auditfinds an agent not identified in one of the following queues:

• idle agents

• busy agents

• not-ready agents

The lost ACD agent is deactivated. The report shows the corrupted queueand the ACD group of the agent.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatACD110 mmmdd hh:mm:ss ssdd INFO BAD_ACD_AGENT

len DN dn

ACD AGENT DEACTIVATED FROM ACD GROUP: grpnm

CALL ID: nnnnnn

REASON: rsntxt

41

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 42: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFOBAD_ACD_AGENT

Constant Fixed Indicates that the ACD agent was lost.

len Symbolic text Variable Provides the len HOST equipmentidentification for the lost agent.

dn Symbolic text Variable Provides the directory number for thelost agent.

ACD AGENTDEACTIVATEDFROM GROUP:grpnm

Customer dataTableACDGRP

Variable Indicates ACD group, from customerdata Table ACDGRP, to which thedeactivated agent belongs.

CALLID: nnnnnn 6-digit number Variable Identifies the unique call identificationthat call processing assigns.

REASON: rsntxt Character string Variable Identifies the corrupt queue. Thereason message can be one of thefollowing:

MSBQ_CORRUPT Variable Indicates that the message busyqueue is corrupt.

IDLEQ_CORRUPT Variable Indicates that the idle queue iscorrupt.

NOTRDYQ_CORRUPT

Variable Indicates that the not-ready queue iscorrupt.

BUSYQ_CORRUPT Variable Indicates that the busy queue iscorrupt.

Active message exampleACD110 APR01 02:11:10 1023 INFO BAD_ACD_AGENT

HOST 00 1 05 00 DN 9097224111

ACD AGENT DEACTIVATED FROM ACD GROUP: TESTGROUP

CALL ID: 123456

REASON: IDLEQ_CORRUPT

Clear message examplen/a

42 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 43: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ACD121The Automatic Call Distribution (ACD) subsystem generates ACD121. Thisreport appears when the ACD audit finds an ACD agent position that is notin queue. The agent should be in queue (idle, busy, or not_ready). Theaudit sends the agent to the idle queue.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatACD121 mmmdd hh:mm:ss ssdd RTS

ACD_AGENT_AUTO_ACTIVATED

len DN dn

RESTORED TO IDLE QUEUE FOR ACD GROUP: grpnm

Selected field descriptionsField Value Fixed or

VariableDescription

INFO ACD_AGENT_AUTO_ACTIVATED

Constant Fixed Indicates that audit sent misplacedagent went to the idle agent queue.

len Symbolic text Variable Provides the len host equipmentidentification for reactivated agent.Refer to Table 1.

dn Symbolic text Variable Provides the ten digit directorynumber for reactivated agent. Refer toTable 1.

RESTORED TO IDLEQUEUE FOR ACDGROUP: grpnm

Table ACDGRP Variable Indicates ACD group, from customerdata Table ACDGRP, to which thereactivated agent belongs.

Active message exampleACD121 APR03 14:06:28 7101 RTS ACD_AGENT_AUTO_ACTIVATED

HOST 02 0 01 08 DN 9097227630

ACD121 43

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 44: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

RESTORED TO IDLE QUEUE FOR ACD GROUP: TESTGROUP

Clear message examplen/a

Associated OM registers

ACD130The Automatic Call Distribution (ACD) subsystem generates ACD130when the ACD audit encounters an invalid agent in the idle, busy, ornot_ready queue. The system cuts the queue off at the point of the badagent. The bad agent and any subsequent agents leave the queue. Thecorrupt ACD queue appears in the report.

This condition causes log reports ACD110, ACD121, and ACD130 to print.After generation of these logs, the queues return to a normal condition.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatACD130 mmmdd hh:mm:ss ssdd INFO CORRUPT_ACD_QUEUE

AGENTS LOST FROM ACD GROUP: grpnm

REASON: rsntxt

Selected field descriptionsField Value Fixed or

VariableDescription

INFOCORRUPT_ACD_QUEUE

Constant Fixed Indicates that the audit detectedinvalid agent.

AGENTS LOSTFROM ACD GROUP:grpnm

Customer data TableACDGRP

Variable Indicates the ACD group, fromcustomer data Table ACDGRP, towhich the lost agent belongs.

REASON: rsntxt Character string Variable Identifies the corrupt queue. Thereason message can be one of thefollowing values.

44 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 45: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

MSBQ_CORRUPT Variable Indicates that the message busyqueue is corrupt.

IDLEQ_CORRUPT Variable Indicates that the idle queue iscorrupt.

NOTRDYQ_CORRUPT

Variable Indicates that the not-ready queue iscorrupt.

BUSYQ_CORRUPT Variable Indicates that the busy queue iscorrupt.

Active message exampleACD130 APR01 02:11:41 2336 INFO CORRUPT_ACD_QUEUE

AGENTS LOST FROM ACD GROUP: TESTGROUP

REASON: MSB_CORRUPT

Clear message examplen/a

Associated OM registers

ACMS100-Canada onlyThe Stored Program Control-Call Management Service (SPC_CMS)subsystem generates report ACMS100. The report appears when an SPCtrunk index from the central office data processor (CODP) does not enterTable SPCTRKS. Because the call cannot link to a per trunk signaling(PTS) trunk, the calling line identification (CLID) cannot link to a call.

Remedial actionVerify that the SPC trunk circuit index reported in the log does not appearin Table SPCTRKS. From the CPN, determine the source of the TCAPCLID message. At the SPC switch, determine the trunk name thatcorresponds to the SPC trunk circuit index. Use the same trunk circuitindex for the same trunk circuit to coordinate the data for DMS andenhanced stored program control (ESPC).

AttributesAttribute Value

Severity Warning

ACMS100-Canada only 45

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 46: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FormatACMS100 mmmdd hh:mm:ss ssdd INFO SPC_CMS UNKNOWN INDEX

cpn cpn_present

clg_name private

unique test_call

orig_cld orig_cld_present

orig_cld_priv

trunk_id trunk_name

cld

Selected field descriptionsField Value Fixed or

VariableDescription

INFO SPC_CMS;UNKNOWN INDEX

Constant Fixed Indicates the SPC trunk index is notpresent in Table SPCTRKS

cpn Integers Variable Indicates the calling party number(CPN). This field appears only whenthe CPN present indicates "Y".

N/A Variable Indicates the CPN not available

cpn_present Y Variable Indicates the CPN is present

N Variable Indicates the CPN is not present

clg_name Symbolic text Variable Indicates the calling name

N/A Variable Indicates the transaction capabilitypart (TCAP) CLID does not providethe calling name

private Y Variable Indicates the display of the CPN at theterminating line is not permitted

N/A Variable Indicates the CPN is not present

unique Y Variable Indicates the CPN is unique

N Variable Indicates the CPN is not unique

N/A Variable Indicates the CPN is not available

test_call Y Variable Indicates the system generated thecall as part of the system test

N Variable Indicates the call was not generatedas part of the system test

46 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 47: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

orig_cld Integers Variable Indicates the originally called partynumber. This field appears when theorig_cld_present indicates "Y".

orig_cld_present Y Variable Indicates the originally called numberis present

N Variable Indicates the originally called numberis not present

N/A Variable Indicates the originally called partynumber is not available. This fieldappears when orig_cld_numberindicates "N".

orig_cld_priv Y Variable Indicates the display of the originallycalled party number is not permitted atthe terminating line

N/A Variable Indicates the originally called partynumber is not available

trunk_id 0-8191 Variable Identifies the SPC trunk circuit

trunk_name Symbolic text Variable Indicates the trunk name thatcorresponds to the SPC trunkidentifier. Refer to Table SPCTRKS.

N/A Variable Indicates the trunk_id does notcorrespond to an entry in the TableSPCTRKS

cld Integers Variable Indicates the last four digits of thecalled party number

Active message exampleACMS100 DEC08 14:48:26 7544 INFO SPC_CMS UNKNOWN INDEX

CPN = 6137225868

CLG NAME = JIM SMITH

UNIQUE = Y

ORIG CLD = N/A

ORIG CLD PRIV = N/A

TRUNK ID = 371

CLD = 3010

ACMS100-Canada only 47

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 48: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

CPN PRESENT = Y

PRIVATE = N

TEST CALL = N

ORIG CLD PRESENT = N

TRUNK NAME = N/A

Clear message examplen/a

Associated OM registers

ACMS101-Canada onlyThe Stored Program Control-Call Management Service (SPC_CMS)subsystem generates ACMS101. The report appears when the systemreceives a transaction capability application part (TCAP) calling lineidentification (CLID) message. The message is for a trunk that, because ofits state, cannot carry a call. No CLID queues against this trunk.

Remedial actionThe following list indicates the causes and actions required for this error:

• The enhanced stored program control (ESPC) attempts originations ona trunk that cannot receive calls. Monitor the trunk circuit for this event.

• Uncoordinated datafill is present between the ESPC and the DMS.Verify that the trunk circuit index the ESPC is sending corresponds tothe same trunk circuit index the DMS expects for that PTS trunk. In theevent of a mismatch, correct the data entry.

AttributesAttribute Value

Severity Warning

FormatACMS101 mmmdd hh:mm:ss ssdd INFO SPC_CMS TRUNK OUT OFSERVICE

cpn cpn_present

clg_name private

unique test_call

48 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 49: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

orig_cld orig_cld_present

orig_cld_priv

trunk_id trunk_name

cld

Selected field descriptionsField Value Fixed or

VariableDescription

INFO SPC_CMSTRUNK OUT OFSERVICE

Constant Fixed Indicates the system generates thereport and receives the TCAP CLIDmessage for a trunk that is out ofservice

cpn Integers Variable Indicates the calling party number(CPN). This field appears only whenthe CPN present indicates "Y"

N/A Variable Indicates the CPN is not available

cpn_present Y Variable Indicates the CPN is present

N Variable Indicates the CPN is not present

clg_name Symbolic text Variable Indicates the calling name

N/A Variable Indicates the TCAP CLID does notprovide the calling name

private Y Variable Indicates the display of the CPN at theterminating line is not permitted

unique Y Variable Indicates the CPN is unique

N Variable Indicates the CPN is not unique

test_call Y Variable Indicates the system generated thecall as part of a system test

N Variable Indicates the call was not generatedas part of a system test

orig_cld Integers Variable Indicates the original called partynumber. This field appears when theorig_cld_present indicates "Y"

orig_cld_present Y Variable Indicates the original called number ispresent

N Variable Indicates the original called number isnot present

ACMS101-Canada only 49

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 50: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

N/A Variable Indicates the original called partynumber is not available. This fieldappears when orig_cld_numberindicates "N"

orig_cld_priv Y Variable Indicates the display of the originalcalled party number is not permitted atthe terminating line

N/A Variable Indicates the original called number isnot present

trunk_id 0-8191 Variable Identifies the stored program control(SPC) trunk circuit

trunk_name Symbolic text Variable Indicates the trunk name thatcorresponds to the SPC trunkidentifier. Refer to Table SPCTRKS

N/A Variable Indicates the trunk_id does notcorrespond to Table SPCTRKS

cld Integers Variable Indicates the last four digits of thecalled party number

Active message exampleACMS101 DEC08 14:48:26 7544 INFO SPC_CMS TRUNK OUT OFSERVICE

CPN = 6137225868

CLG NAME = JIM SMITH

UNIQUE = Y

ORIG CLD = N/A

ORIG CLD PRIV = N/A

TRUNK ID = 326

CLD = 3010

CPN PRESENT = Y

PRIVATE = N

TEST CALL = N

50 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 51: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

ORIG CLD PRESENT = N

TRUNK NAME = ITDP1 7

Clear message examplen/a

Associated OM registers

ACMS102-Canada onlyThe Stored Program Control-Call Management Service (SPC-CMS)subsystem generates ACMS102-Canada. This report appears when anincoming call does not take calling line identification (CLID) data out of thetrunk circuit queue within the time limit. Office parameterSPCCLITIMEOUT sets the time limit. The SPC-CMS subsystem alsogenerates ACMS102 if SPCCLITIMEOUT is set too low.

Remedial actionThe following list gives the causes and actions required to correct thiserror.

• Verify that the system coordinates data entry between the enhancedstored program control (ESPC) and the DMS switch.

• The value of office parameter SPCCLITIMEOUT is set too low.Increase this parameter and continue monitoring the system for achange in the frequency of this log. Adjust the value until this log doesnot appear.

• The per trunk signaling (PTS) trunk calls do not complete. Correct anyPTS trunk failure and verify that this error condition no longer exists.

• The system abandons the call after the central office data processor(CODP) sends the TCAP CLID message. This condition is not an error.You do not need to take additional action.

AttributesAttribute Value

Severity Warning

FormatACMS102 mmmdd hh:mm:ss ssdd INFO SPC-CMS CLID EXPIRY

cpn cpn_present

clg_name private

ACMS102-Canada only 51

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 52: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

unique test_call

orig_cld orig_cld_present

orig_cld_priv

trunk_id trunk_name

cld

Selected field descriptionsField Value Fixed or

VariableDescription

INFO SPC-CMSUNKNOWN INDEX

Constant Fixed Indicates that incoming call did notdequeue CLID data within thepermitted time

cpn Integers Variable Indicates the calling party number(CPN). This field only appears whenthe CPN indicates "Y"

N/A Variable Indicates the CPN is not available

cpn_present Y Variable Indicates the CPN is available

N Variable Indicates the CPN is not present

clg_name Symbolic text Variable Indicates the calling name

N/A Variable Indicates that the TCAP CLID doesnot provide the calling name

private Y Variable Indicates the display of the CPN at theterminating line is not permitted

N/A Variable Indicates the CPN is not present

unique Y Variable Indicates the CPN is unique

N Variable Indicates the CPN is not unique

test_call Y Variable Indicates if the system generated thecall as part of the system test

N Variable Indicates the system call did notgenerate the call

orig_cld_present Y Variable Indicates if the originally callednumber is present

N Variable Indicates the originally called numberis not present

orig_cld Integers Variable Indicates the originally called partynumber. This field appears when theorig_cld_present indicates "Y".

52 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 53: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

N/A Variable Indicates the originally called partynumber is not available. This fieldappears when orig_cld_numberindicates "N".

orig_cld_priv Y Variable Indicates the display of the originallycalled party number is not permitted atthe terminating line

N/A Variable Indicates the originally called numberis not present

trunk_id 0-8191 Variable Identifies the stored program control(SPC) trunk circuit

trunk_name Symbolic text Variable Indicates the trunk name thatcorresponds to the SPC trunkidentifier. Refer to Table SPCTRKS

N/A Variable Indicates the trunk_id does notcorrespond to an entry in TableSPCTRKS

cld Integers Variable Indicates the last four digits of thecalled party number

Active message exampleACMS102 DEC08 14:48:26 7544 INFO SPC-CMS CLID EXPIRY

CPN = 6137225868 CPN PRESENT = Y

CLG NAME = JIM SMITH PRIVATE = N

UNIQUE = Y TEST CALL = N

ORIG CLD = 6137221149 ORIG CLD PRESENT = Y

ORIG CLD PRIV = N

TRUNK ID = 326 TRUNK NAME = ITDP1 7

CLD = 3010

Clear message examplen/a

ACMS102-Canada only 53

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 54: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ACMS103-Canada onlyThe Stored Program Control-Call Management Service (SPC-CMS)subsystem generates log report ACMS103-Canada only. This reportappears when a calling line identification (CLID) message enters a trunkcircuit queue that already has CLID data. The new CLID overwrites thecurrent CLID data, which is lost.

Remedial actionThe following list gives the causes and actions required for this error:

• Multiple enhanced stored program controls (ESPCs) use a singlestored program control (SPC) trunk circuit identifier. Verify that thiscondition is not the case.

• A call arrives after an abandon on the same circuit. The TCAP CLIDmessage sent with the abandoned call remains in a queue against thecircuit. Make sure the value of office parameter SPCCLITIEOUT issufficiently low to remove abandoned CLID messages in acceptabletime. Do not set SPCCLITIMEOUT so low as to cause ACMS102 logs.The SPCCLITIMEOUT determines the lowest possible value that doesnot cause ACMS102 logs.

AttributesAttribute Value

Severity Warning

FormatACMS103 mmmdd hh:mm:ss ssdd INFO SPC_CMS CLID OVERWRITE

cpn cpn_present

clg_name private

unique test_call

orig_cld orig_cld_present

orig_cld_priv

trunk_id trunk_name

cld

54 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 55: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFO SPC-CMS CLIDOVERWRITE

Constant Fixed Indicates that new CLID data replacesold CLID data

cpn Integers Variable Indicates the calling party number.This field appears only when the cpn-present field indicates the letter Y.

N/A Variable Indicates the calling party number(CPN) is not available

cpn_present Y Variable Indicates the CPN is present

N Variable Indicates the CPN is not present

clg_name Symbolic text Variable Indicates the calling name

N/A Variable Indicates the TCAP CLID does notprovide the calling name

private Y Variable Indicates the display of the CPN at theterminating line is not permitted

N Variable Indicates the display of the CPN at theterminating line is permitted

N/A Variable Indicates the CPN is not present

unique Y Variable Indicates the CPN is unique

N Variable Indicates the CPN is not unique

N/A Variable Indicates the CPN is not available

test_call Y Variable Indicates the system generated thecall as part of a system test

N Variable Indicates the call was not generatedas part of a system test

orig_cld Integers Variable Indicates the original CPN. This fieldappears when the orig_cld_presentindicates "Y".

N/A Variable Indicates the original CPN is notavailable.

This field appears whenorig_cld_present field indicates theletter N.

orig_cld_present Y Variable Indicates the original CPN is present

N Variable Indicates the original CPN is notpresent

ACMS103-Canada only 55

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 56: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

orig_cld_priv Y Variable Indicates the display of the originalCPN is not permitted at theterminating line

N/A Variable Indicates the original CPN is notavailable

trunk_id 0-8191 Variable Identifies the stored program control(SPC) trunk circuit

trunk_name Symbolic text Variable Indicates the trunk name thatcorresponds to the SPC trunkidentifier. Refer to Table SPCTRKS.

cld Integers Variable Indicates the last four digits of theCPN

Active message exampleACMS103 DEC08 14:48:26 7544 INFO SPC-CMS CLID OVERWRITE

CPN = 6137225868 CPN PRESENT = Y

CLG NAME = JIM SMITH PRIVATE = N

UNIQUE = Y TEST CALL = N

ORIG CLD = N/A ORIG CLD PRESENT = N

ORIG CLD PRIV = N/A

TRUNK ID = 326 TRUNK NAME = ITDP1 7

CLD = 3010

Clear message examplen/a

Associated OM registers

ACMS104-Canada onlyThe Stored Program Control-Call Management Services (SP C_CMS)subsystem generates log report ACMS104-Canada only. This reportappears when the following two digit sets do not match:

• the last four digits of the called number in the TCAP CLID message

• the last four digits of the called number that the enhanced storedprogram control (ESPC) transmits

56 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 57: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

This check lowers the probability that the system will pick up the TCAPCLID message for the previous call on the trunk circuit.

Remedial actionThe following list gives the causes and the actions required to correct thiserror:

• Multiple enhanced stored program controls (ESPCs) use a singlestored program control (SPC) trunk circuit identifier. As a result, TCAPCLID messages arrive from both the correct source and a source thatis not correct. The system also generates ACMS102 and ACMS103.Trace the CPNs and trunk names to the originating switch. If you findmore than one originating switch, correct the use of SPC trunk by theSPC switches.

• A call is abandoned after the system sends the TCAP CLID messagegoes out, but before the call starts to transmit. If a second call routesover the DMS-100 Family NA 100 Log Report Reference ManualVolume 1 of 8 LET0015 and up trunk without a TCAP CLID message, amismatch occurs. The SPC switch will not send TCAP CLID messagesfor calls known to terminate on another SPC switch. Examine the calleddigits in the log. Verify that the system should not have send a TCAPCLID message for that line number.

• The DMS translation system changes the digits transmitted from theESPC before the digits comparison. This condition only occurs on DPtrunks where translation starts before the ESPC transmits all digits. Anexample of this condition is use of the ''R'' or replace selector in TableHNPACODE. This selector forces replacement of the dialed digits witha new set.

AttributesAttribute Value

Severity Warning

FormatACMS104 mmmdd hh:mm:ss ssdd INFO SPC_CMS DIGITS MISMATCH

cpn cpn_present

clg_name private

unique test_call

orig_cld orig_cld_present

orig_cld_priv

ACMS104-Canada only 57

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 58: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

trunk_id trunk_name

cld

called_dr

Selected field descriptionsField Value Fixed or

VariableDescription

INFO SPC_CMSDIGITS MISMATCH

Constant Fixed Indicates the mismatch of digitsbetween the called number in theTCAP CLID and called number thatthe enhanced stored program control(ESPC) indicates

cpn nnnnnnnnnn Variable Indicates the calling party number(CPN). This field appears when thecpn_present field indicates "Y".

N/A Variable Indicates the CPN is not available

cpn_present Y Variable Indicates the CPN is present

N Variable Indicates the CPN is not present

clg_name aaaaaaaaaaaaaaa Variable Indicates the calling name

N/A Variable Indicates the TCAP CLID does notprovide the calling name.

private Y Variable Indicates the display of the CPN at theterminating line is not permitted

N Variable Indicates the display of the CPN at theterminating line is permitted

N/A Variable Indicates the CPN is not present

unique Y Variable Indicates the CPN is unique

N Variable Indicates the CPN is not unique

test_call Y Variable Indicates the system generated thecall as part of a system test

N Variable Indicates the call was not generatedthe call as part of a system test

orig_cld nnnnnnnnnn Variable Indicates the original CPN. This fieldappears when the orig_cld_presentfield indicates "Y".

N/A Variable Indicates the originally called partynumber is not available. This fieldappears when the orig_cld_presentfield indicates "N".

58 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 59: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

orig_cld_present Y Variable Indicates the originally called partynumber is present

N Variable Indicates the originally called partynumber is not present

orig_cld_priv Y Variable Indicates the display of the originallycalled party number is not permitted atthe terminating line

N/A Variable Indicates the originally called partynumber as not available

trunk_id 0-8191 Variable Identifies the stored program control(SPC) trunk circuit

trunk_name Refer to TableSPCTRKS

Variable Indicates the trunk name thatcorresponds to the SPC trunkidentifier

cld nnnn Variable Indicates the last four digits of thecalled number in the TCAP CLIDmessage. The system uses this valueto verify that the system picks up thecorrect message.

called_dr nnnnnnn Variable Indicates the called number recoveredfrom the called digit register. Thesystem uses the last four digits tocompare with the CLD in the TCAPCLID message.

Active message exampleACMS104 DEC08 14:48:26 7544 INFO SPC_CMS DIGITS MISMATCH

CPN = 6137225868

CLG NAME = JIM SMITH

UNIQUE = Y

ORIG CLD = N/A

ORIG CLD PRIV = N/A

TRUNK ID = 326

CLD = 3010

CALLED_DR = 2246010

ACMS104-Canada only 59

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 60: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

CPN PRESENT = Y

PRIVATE = N

TEST CALL = N

ORIG CLD PRESENT = N

TRUNK NAME = ITDP1 7

Clear message examplen/a

Associated OM registers

ACMS105-Canada onlyThe Stored Program Control-Call Management Service (SPC-CMS)subsystem generates log report ACMS105-Canada only. This reportappears when an SPC trunk receives an origination but does not havecalling line identification (CLID) data in a queue. The voice call continueswithout CLID. To generate this log, set office parameterACMS_NOC_LOG_ON to YES.

Remedial actionThe following list gives the causes and actions required to correct thiserror:

• The SPC switch does not send a TCAP CLID message for the callbecause the terminating switch does not support CMS features. Usethe CALLED DR value to determine if the terminating switch supportsCMS features. Verify at the SPC switch end that other switches do notsend TCAP CLID messages for calls with that destination.

• The CLID messages arrive but time out before the voice call arrives.The system also generates ACMS102. Adjust the office parameterSPCLITIMEOUT until ACMS102 logs no longer appear.

• The TCAP CLID messages encoded for this trunk have the wronglabel, the SPC trunk index of another trunk. Logs ACMS100,ACMS101, ACMS102, ACMS103, or ACMS104 also occur. Correct thedata entry on the originating switch.

60 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 61: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• The TCAP CLID messages arrive with data errors or wrong SPC trunkindexes, or come during resource shortfalls. To confirm the reason,check OM registers ACMSDERR, ACMSIDX, and ACMSOVFL in OMgroup ACMS. Counts in these registers indicate error conditions forwhich the TCAP CLID message cannot enter a queue.

• The TCAP CLID messages are not passing through the network. Thiscondition can result from congestion in the CCS7 network or a fault ofsome type. Check the status of the CCS7 links that connect the DMSswitch to the originating SPC.

AttributesAttribute Value

Severity Warning

FormatACMS105 mmmdd hh:mm:ss ssdd INFO SPC-CMS NO CLID

trunk_id trunk_name

called_dr

Selected field descriptionsField Value Fixed or

VariableDescription

INFO SPC-CMS NOCLID

Constant Fixed Indicates that CLID data is not in thequeue against the SPC trunk thatreceives the origination

trunk_id 0-8191 Variable Identifies the stored program control(SPC) trunk circuit

trunk_name Symbolic text Variable Indicates the trunk name thatcorresponds to the SPC trunkidentifier. Refer to Table SPCTRKS.

called_dr Integers Variable Indicates the called number recoveredfrom the called digit register. Use thelast four digits to compare with theCLD field received in the TCAP CLIDmessage.

Active message exampleACMS105 DEC08 14:48:26 7544 INFO SPC-CMS NO CLID

TRUNK ID = 354

TRUNK NAME = ITDP1 4

ACMS105-Canada only 61

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 62: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

CALLED DR = 2246010

Clear message examplen/a

Associated OM registers

ACT100The Activity (ACT) subsystem generates report ACT100 when theSTARTLOG command enters the ACT MAP level. The system generatesthe ACT100 log every 15 min until entry of the STOPLOG commandoccurs. The ACT100 log report contains a summary of call processingactivity at one-min intervals 1 the last 15 min.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatACT100 mmmdd hh:mm:ss ssdd INFO ACTIVITY_DATA#

Catmp/hr nnnnnnnnn Lorig nnnnnnnnn Torig nnnnnnnnn

ToAnn nnnnnnnnn

Cpocc nnn% Conctr nnn% Oavgdel nnms O95%lim nnnms

PavgDel nnms P95%lim nnnms BAvgDel nnms B95%lim nnnms

RTrip nms Origdeny nnnnnnnnn Inefdeny nnnnnnnnn CPloovfl

nnnnnnnnn

CPsuic nnnnnnnnn CPtrap nnnnnnnnn LCMdtsrnnn% LMdtsr nnn%

62 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 63: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

# 1 to 15 Variable Indicates the sequence number of theactivity data. A sequence number of 1indicates the first minute of thereporting period.

INFOACTIVITY_DATA

Constant Fixed Indicates that ACTIVITY data ispresented.

Catmp/hr nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of call attemptsper hour

Lorig nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of callsoriginating on lines

Torig nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of callsoriginating on trunks

ToAnn nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of tones orannouncements given

Cpocc nnn% nnn = 0 to 100 Variable Indicates processing CPU occupancyand percentage of direct CPU that thecall processing function uses.

Conctr nnn% nnn = 0 to 110(expected range)

Variable Indicates the connection ratio of calls(percent)

OAvgDel nnnnms nnnn = 0 to 9999 Variable Indicates the average delay on theCCB originating queue (ms)

O95%lim nnnnms nnnn = 0 to 9999 Variable Indicates the 95% originating limit(ms)

PavgDel nnnnms nnnn = 0 to 9999 Variable Indicates the average delay on theCCB progress queue (ms)

P95%lim nnnnms nnnn = 0 to 9999 Variable Indicates the 95% progress limit (ms)

BavgDel nnnnms nnnn = 0 to 9999 Variable Indicates the background averagedelay (ms)

B95%lim nnnnms nnnn = 0 to 9999 Variable Indicates the 95% background limit.(ms)

Rtrip nnnnms nnnn = 0 to 9999 Variable Indicates the sound trip average delay(ms)

Origdeny nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of originationdenials, when an originating call isdenied immediate service toprotection overload.

ACT100 63

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 64: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Inefdeny nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of ineffectivedenials, when an originating call wasdenied because of a pendingabandon.

CPloovfl nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of CP letterorigination overflows, originationmessages denied a CP letter.

CPsuic nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of call suicides

CPtrap nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of CP traps

LCMdtsr nnn% nnn = 0 to 100 Variable Indicates the percentage of calls,originated in an LCM, that wait longerthan 3 s between off-hook and dialtone.

LMdtsr nnn% nnn = 0 to 100 Variable Indicates the percentage of calls,originated in an LM, that wait longerthan 3 s between off-hook and dialtone.

Active message exampleACT100 FEB24 14:42:02 4200 INFO ACTIVITY_DATA

11 Catmp/hr 61412 Lorig 1023 Torig 0 ToAnn 0

Cpocc 50% Conctr 99% OAvgDel 21ms O95%lim 66ms

PAvgDel 13ms P95%lim 26ms BAvgDel 35ms B95%lim 133ms

RTrip 0ms Origdeny 0 Inefdeny 0 CPloovfl 0

CPsuic 0 CPtrap 0 LCMdtsr 0% LMdtsr 0%

Clear message examplen/a

Associated OM registers

ACT101The Activity (ACT) subsystem generates log report ACT101 when atransient mismatch occurs in the switch.

64 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 65: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionThe monitoring tool activity will stop automatically. This log warns the usernot to start ACTIVITY for 15 min. Refer to log CC105, which the systemgenerates when a transient mismatch occurs.

AttributesAttribute Value

Severity Warning

FormatACT101 mmmdd hh:mm:ss ssdd INFO ACTIVITY_STATUS

Execution of activity stopped due to mismatch.

Please do not invoke activity for 15 minutes.

Selected field descriptionsField Value Fixed or

VariableDescription

INFOACTIVITY_STATUS

Constant Fixed Indicates that the system monitors thestatus of ACTIVITY

Execution of activitystopped due tomismatch.

Constant Fixed Indicates the activity stopped due to amismatch

Please do not invokeactivity for 15 min.

Constant Fixed Indicates activity cannot start for 15min

Active message exampleACT101 Feb10 11:53:22 2536 INFO ACTIVITY_STATUS

Execution of activity stopped due to mismatch.

Please do not invoke activity for 15 minutes.

Clear message examplen/a

Associated OM registers

ACT102The Activity (ACT) subsystem generates log report ACT 102 after entry ofthe STARTLOG command at the ACT MAP level. The subsystemgenerates this report every 15 minutes until entry of the STOPLOG

ACT102 65

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 66: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

command. This report contains a summary of the data in the ACT100 logreports generated during the previous 15 minutes. Log ACT102 appearswhen the subsystem generates three ACT100 reports.

Total the data in the fields that correspond in the ACT100 logs to generatedata in the following fields: Origdeny, Inefdeny, CPloovfl, CPsuic, CPtrap.All other fields are averages.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatACT102 mmmdd hh:mm:ss ssdd INFO ACTIVITY_SUMMARY

Summary: Catmp/hr nnnnnnnnn Lorig nnnnnnnnn Torig nnnnnnnnn

ToAnn nnnnnnnnn

Cpocc nnn% Conctr nnn% Oavgdel nnms O95%lim nnnms

PavgDel nnms P95%lim nnnms BAvgDel nnms B95%lim nnnms

RTrip nms Origdeny nnnnnnnnn Inefdeny nnnnnnnnn CPloovfl

nnnnnnnnn

CPsuic nnnnnnnnn CPtrap nnnnnnnnn LCMdtsrnnn% LMdtsr nnn%

Selected field descriptionsField Value Fixed or

VariableDescription

INFOACTIVITY_SUMMARY

Constant Fixed Indicates that a summary of ACTIVITYappears.

Summary: Constant Fixed Indicates that the summary follows.

Catmp/hr nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of call attemptsfor each hour.

Lorig nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of calls thatoriginate on lines.

66 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 67: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Torig nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of calls thatoriginate on trunks

ToAnn nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of tones orannouncements provided.

Cpocc nnn% nnn = 0 to 100 Variable Indicates processing CPU occupancy.The processing occupancy is thepercentage of direct CPU use by thecall processing function.

Conctr nnn% nnn = 0 to 110(expected range)

Variable Indicates the connection ratio of calls(percent).

OAvgDel nnnnms nnnn = 0 to 9999 Variable Indicates the average delay on theCCB originating queue (milliseconds).

095%lim nnnnms nnnn = 0 to 9999 Variable Indicates the 95% originating limit(milliseconds).

PavgDel nnnnms nnnn = 0 to 9999 Variable Indicates the average delay on theCCB progress queue (milliseconds).

P95%lim nnnnms nnnn = 0 to 9999 Variable Indicates the 95% progress limit(milliseconds).

BavgDel nnnnms nnnn = 0 to 9999 Variable Indicates the background averagedelay (milliseconds).

B95%lim nnnnms nnnn = 0 to 9999 Variable Indicates the 95% background limit(milliseconds).

Rtrip nnnnms nnnn = 0 to 9999 Variable Indicates the sound trip average delay(milliseconds).

Origdeny nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of times thesystem denied immediate service toan originating call to provideprotection in overload.

Inefdeny nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of times that apending abandon caused the systemto deny an originating call.

CPloovfl nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of CP letterorigination overflows. The CP letterorigination overflows are the numberof originating messages denied a CPletter.

CPsuic nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of call suicides.

CPtrap nnnnnnnnn nnnnnnnnn = 0 to999999999

Variable Indicates the number of CP traps.

ACT102 67

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 68: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

LCMdtsr nnn% nnn = 0 to 100 Variable The percentage of calls that originatein an LCM and wait longer than 3seconds between off-hook and dialtone.

LMdtsr nnn% nnn = 0 to 100 Variable The percentage of calls that originatein an LM and wait longer than 3seconds between off-hook and dialtone.

Active message exampleACT102 FEB24 14:42:02 4200 INFO ACTIVITY_SUMMARY

Summary:Catmp/hr 61412 Lorig 1023 Torig 0 ToAnn 0

Cpocc 50% Conctr 99% OAvgDel 21ms O95%lim 66ms

PAvgDel 13ms P95%lim 26ms BAvgDel 35ms B95%lim 133ms

RTrip 0ms Origdeny 0 Inefdeny 0 CPloovfl 0%

CPsuic 0 CPtrap 0 LCMdtsr 0% LMdtsr 0%

Clear message examplen/a

Associated OM registers

AFT003The subsystem generates log report AFT003 when AFT error conditionsoccur, and at other times. This log report provides information about theAFT system.

Remedial actionThe text field describes any action required.

AttributesAttribute Value

Severity Warning

FormatAFT003 mmmdd hh:mm:ss ssdd AFT INFORMATIONAL

68 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 69: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

TEXT = textmsg

= textmsg

SESSION= session name SUBSYSTEM= subsystem

CODE = integer

Selected field descriptionsField Value Fixed or

VariableDescription

AFTINFORMATIONAL

Constant Fixed Indicates that this log is an AFTinformational log.

TEXT Symbolic text Variable The first textmsg indicates the reasonfor the error and/or the action to take.The second textmsg indicates themessage location in code.

SESSION alphanumeric Variable Indicates the session name that TableGASINFO defines.

SUBSYSTEM alphanumeric Variable Indicates the name of the DIRPsubsystem.

CODE numeric Variable This field is for troubleshooting.

Active message exampleAFT003 JAN01 16;02:24 4608 AFT INFORMATIONAL

TEXT = Specific Override Requested File Name

= U8803101226010CC

SESSION= AFT1 SUBSYSTEM= OCC

CODE = 0000

Clear message examplen/a

Associated OM registers

AIN300The advanced intelligent network (AIN) subsystem generates log AIN300.Log AIN300 is generated when the service control point (SCP) control listoverflows. The SCP control list overflows when the subsystem attempts toadd a control to a full list. The subsystem does not add the control and the

AIN300 69

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 70: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

service switching point (SSP) does not operate according to the SCPrequest. The degree of seriousness of the overflow condition depends onthe network condition at the time of the request.

The subsystem generates log AIN300 once per five minute period. LogAIN300 lists the number of attempts to generate this log in theUNREPORTED_OVERFLOWS field.

Log AIN300 is for AIN Essentials and subsequent releases.

Use table LOGCLASS to suppress generation of log AIN300. Do not usetable LOGCLASS to report thresholding of log AIN300. The ACGapplication performs the thresholding.

Remedial actionAnalyze the SCP control list for old controls. To delete old controls, usecommand ACGDELETE in the CI AINCI directory.

AttributesAttribute Value

Severity Indeterminate

Formatoffice * AIN300 mmmdd hh:mm:ss seqno TBL ACG/SOCC SCPControl List Overflow

AIN ACG SCP Control List Overflow

ACTION: Analyze list for stale controls.

GTA: <>TT_Name: <>

UNREPORTED_OVERFLOWS: <>

70 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 71: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

GTA NPANXXXXXX Variable The Global Title Address, indicatesthe call or charge number on which togap queries.

TT_Name As entered in tableC7GTTYPE, fieldGTTNAME

Variable Translation type name can indicate aservice, a group of services, or asoftware release. The TT_Namedepends on entries.

UNREPORTED_OVERFLOWS

numeric Variable Indicates the number of attemptsmade to generate this log report fromthe generation of the last report of thistype. The ACG application suppressesattempts to generate this report withinfive minutes of a report that thesubsystem, generated earlier.

Active message exampleCOMR05AB * AIN300 Feb01 14:25:44 1400 TBL ACG/SOCC SCP

Control List Overflow

AIN ACG SCP Control List Overflow

ACTION: Analyze list for stale controls.

GTA: 613722 TT_Name: AINJAZZ

UNREPORTED_OVERFLOWS: 4

Clear message examplen/a

Associated OM registers

AIN301The advanced intelligent network (AIN) subsystem generates log AIN301when the SMS control list overflows. The SMS control list overflows whenan attempt is made to add a control when the list is full. The system doesnot add the control and the SSP does not behave according to the SMSrequest. The condition of the network at the time of the request,determines the severity of this condition.

AIN301 71

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 72: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The system generates log AIN301 once per 5-min period. Log AIN301 liststhe number of attempts to generate this log since the last report. Thisinformation appears in the UNREPORTED_OVERFLOWS field.

Log AIN301 applies to AIN Essentials and subsequent releases.

Use table LOGCLASS to suppress generation of this report. Do not usetable LOGCLASS to perform threshold reports for log AIN301, because theACG application performs the thresholding.

Remedial actionAnalyze the SMS control list for stale controls. Use commandACGDELETE in the CI AINCI directory to delete any stale controls.

AttributesAttribute Value

Severity Indeterminate

Formatoffice * AIN301 mmmdd hh:mm:ss seqno TBL ACG/SOCC SMS

Control List Overflow

AIN ACG SMS Control List Overflow

ACTION: Analyze list for stale controls.

GTA: <>TT_Name: <>

UNREPORTED_OVERFLOWS: <>

Selected field descriptionsField Value Fixed or

VariableDescription

GTA NPANXXXXXX Variable Global title address indicates the callor charge number to gap queries on.

TT_Name As entered in tableC7GTTYPE, fieldGTTNAME

Variable Translation type name can indicate aservice, a group of services, or asoftware release. The type dependson the entry.

UNREPORTED_OVERFLOWS

numeric Variable This field indicates the number ofattempts made to generate this logreport. The measurement is madesince the generation of the last report

72 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 73: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

of this type. The ACG applicationsuppresses attempts to generate thisreport within 5 min of an earlier report.

Active message exampleCOMR05AB * AIN301 Feb01 14:25:44 1400 TBL ACG/SOCC SMSControl List Overflow

AIN ACG SMS Control List Overflow

ACTION: Analyze list for stale controls.

GTA: 613722 TT_Name: AINJAZZ

UNREPORTED_OVERFLOWS: 4

Clear message examplen/a

Associated OM registers

AIN302The advanced intelligent network (AIN) subsystem generates log AIN302when the SSP receives an ACG message that contains a translation type(TT), that is not currently datafilled in table C7GTTYPE for the SSP.

Log AIN302 is generated, at most, once in any 5-min period. On thesubsequent report, the number of attempts to generate this log since theprevious report is listed in the SUPPRESSED field.

Log AIN302 pertains to AIN Essentials and subsequent releases.

Table LOGCLASS suppresses generation of log AIN302. Do not use tableLOGCLASS to threshold reporting of log AIN302, because thresholding isperformed by the ACG application.

Remedial actionCheck table C7GTTYPE to determine whether the TT number is presentand whether it should be included in the table.

AIN302 73

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 74: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Indeterminate

Formatoffice * AIN302 mmmdd hh:mm:ss seqno TBL Unknown TT

AIN ACG Unknown Translation Type number.

ACTION: Check table C7GTTYPE for the specified TT number.

List Type: <>GTA: <>TT: <>

SUPPRESSED: <>

Selected field descriptionsField Value Fixed or

VariableDescription

List_Type SCP or SMS Variable Indicates:

• SCP control list for automaticcontrols

• SMS control list for manualcontrols

GTA NPANXXXXXX Variable Global title address. Indicates thecalled or charge number to gapqueries.

TT As entered in tableC7GTTYPE, fieldGTNUM

Variable Translation type. Can indicate aservice, a group of services, or asoftware release, depending ondatafill.

SUPPRESSED numeric Variable Indicates the number of attempts thatwere made to generate this log reportsince the last report of this type wasgenerated. Attempts to generate thisreport within 5 min of a previouslygenerated report are suppressed bythe ACG application.

Active message exampleCOMR05AB * AIN302 Feb01 14:29:08 0600 TBL Unknown TT

AIN ACG Unknown Translation Type number.

ACTION: Check table C7GTTYPE for the specified TT number.

74 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 75: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

List Type: SCP

GTA: 613722 TT: 6

SUPPRESSED: 0

Clear message examplen/a

Associated OM registers

AIN303The advanced intelligent network (AIN) subsystem generates log AIN303when the SSP receives an ACG message. The ACG work queue is fullwhen this log is generated.

The system generates log AIN303 once per 5-min period, lists the numberof attempts to generate this log from the previous report in theSUPPRESSED field.

Use table LOGCLASS to suppress this report. Do not use tableLOGCLASS to perform a threshold report for log AIN303, because theACG application performs thresholding.

Remedial actionThe ACG work queue runs at SOS Scheduler class AUXCP. Use officeparameter AUXCP_CPU_SHARE in table OFCENG to set the time sliceavailable to AUXCP. Use caution when you change parameterAUXCP_CPU_SHARE, because many other office applications useAUXCP.

AttributesAttribute Value

Severity Indeterminate

Formatoffice * AIN303 mmmdd hh:mm:ss seqno TBL ACG/SOCC_Queue

AIN ACG Work Queue Overflow

ACTION: Increase processor time for ACG.

SUPPRESSED: <>

AIN303 75

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 76: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

SUPPRESSED numeric Variable Indicates the number of attempts togenerate this log report from thegeneration of the last report of thistype. The ACG application suppressesattempts to generate this report within5 min of an earlier generated report.

Active message exampleCOMR05AB * AIN303 Feb01 14:29:08 0600 TBL ACG/SOCC_Queue

AIN ACG Work Queue Overflow

ACTION: Increase processor time for ACG.

SUPPRESSED: 2

Clear message examplen/a

Associated OM registers

AIN304The Advanced Intelligent Network (AIN) subsystem generates log AIN304when the SSP receives an ACG message during an image dump.

The system generates this log one time in any 15-min period. The followingreport lists the number of attempts to generate this log from the previousreport in the SUPPRESSED field.

Use table LOGCLASS to suppress generation of this report. Do not usetable LOGCLASS to perform a threshold report for this log. The ACGapplication performs thresholding.

Remedial actionn/a

AttributesAttribute Value

Severity Indeterminate

76 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 77: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Formatoffice * AIN304 mmmdd hh:mm:ss seqno FAIL ACG control notadded

AIN ACG inoperative during image dumps.

ACTION: None.

SUPPRESSED: <>

Selected field descriptionsField Value Fixed or

VariableDescription

SUPPRESSED numeric Variable This field indicates the number ofattempts to generate this log report,from the generation of the last reportof this type. The ACG applicationsuppresses attempts to generate thisreport within 10 min of an earliergenerated report.

Active message exampleCOMR05AB * AIN304 Feb01 14:29:08 0600 FAIL ACG control notadded

AIN ACG inoperative during image dumps.

ACTION: Increase processor time for ACG.

SUPPRESSED: 2

Clear message examplen/a

Associated OM registers

AIN500Log AIN500 records successful AIN Update messages that request achange in activation state for trigger item IDs. Log AIN500 allowstelephone operating companies to monitor changes to the activation statesof trigger items. The log output provides details on each Update messageattempt so that undesirable change requests can be monitored.Downstream processing can monitor the logs and verify the source pointcode and subsystem number (SSN), to validate the service control point(SCP) that requests an update. Log AIN500 can be used to verify that alldesired activation changes are complete.

AIN500 77

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 78: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AIN501 logs are not generated for Individual trigger Item Updates

Remedial actionn/a

AttributesAttribute Value

Severity Indeterminate

Format<load name>* AIN500 <date><time><seqno>TBL Successfull

trigger item update

Message Type: Update

SSP User Resource :<user resource id>= <resource data value>

TDP: e<4 and 17>

SubNum: <N11,LNP,SDS,AFR>

STATE: <ON/OFF>

Source: SCP; PC: <0 to 255>-<0 to 255>-<0 to 255>, SSN: <0to 255>

Selected field descriptionsField Value Fixed or

VariableDescription

Message Type Message Type:Update

Variable Indicates the Update message.

Source SCP or PC: nnn-nnn-nnn, SSN: xxx

Variable The values nnn and xxx are numbersfrom 0-255, representing the pointcode (PC) and the signalingsubsystem number (SSN) of the SCPthat initiated the Update message.

SSP Resource ID Local SSPID Variable Identifies the SSP User Resource IDthat the Update message hasindicated. For NA009, it is a fixedstring.

Trigger DetectionPoint

TDP: e1 to e34 Variable The value identifies the detection pointin the AIN call model.

78 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 79: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Trigger Subnumber Variable

Activation Status State: ON or OFF Variable The value indicates the currentactivation state of the trigger item ID.

Active message exampleCOMR09AJ * AIN500 JAN02 11:52:45 4100 TBL Successfull

trigger item update

Message Type: Update

SSP User Resource: LocalSSPID = TEST

TDP: e17

SubNum: AFR

STATE: OFF

Source: SCP; PC: 253-253-251, SSN: 236

Clear message examplen/a

Associated OM registers

AIN501Log AIN501 records unsuccessful AIN Update message requests foractivation state changes of trigger item IDs.

In the scenarios that follow Log AIN501 is not generated:

• The service switching point (SSP) returns a reject component with anincorrect parameter problem code.

• The SSP returns a failure report indicating a rate-too-high condition.

• The SSP returns an application error indicating an erroneous datavalue, or an unexpected parameter sequence.

AIN501 logs are not generated for Individual trigger Item Updates.

Remedial actionn/a

AIN501 79

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 80: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Indeterminate

Format<load name>* AIN501 <date><time><seqno>TBL Unsuccessful

trigger item update

Message Type: Update

SSP User Resource: <user resource id>= <resource data value>

TDP: e<4 and 17>

SubNum: <N11,LNP,SDS,AFR>

STATE: <ON/OFF>

Source: SCP; PC: <0 to 255>-<0 to 255>-<0 to 255>, SSN: <0to 255>

Selected field descriptionsField Value Fixed or

VariableDescription

Message Type Message Type:Update

Variable Indicates the Update message.

Source SCP or PC: nnn-nnn-nnn, SSN: xxx

Variable The values nnn and xxx are numbersfrom 0-255, representing the pointcode (PC) and the signalingsubsystem number (SSN) of the SCPthat initiated the Update message.

SSP Resource ID Local SSPID Variable Identifies the SSP User Resource IDthat the Update message hasindicated. For NA009, it is a fixedstring.

Trigger DetectionPoint

TDP: e1 to e34 Variable The value identifies the detection pointin the AIN call model.

Trigger Subnumber Variable

Activation Status State: ON or OFF Variable The value indicates the currentactivation state of the trigger item ID.

Active message exampleCOMR09AJ * AIN501 JAN02 11:52:45 4100 TBL Un-successfull

80 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 81: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

trigger item update

Message Type: Update

SSP User Resource: LocalSSPID = TEST

TDP: e4

SubNum: N11TRIG1

STATE: ON

Source: SCP; PC: 253-253-251, SSN: 236

Clear message examplen/a

Associated OM registers

AIN510The advanced intelligent network (AIN) subsystem generates log AIN510when operating company personnel enable automatic call gapping (ACG).

This report indicates the date and time when operating company personnelenabled the ACG.

Log AIN510 applies to AIN Essentials and subsequent releases.

Enable ACG with the ACGONOF command in the AINCI tool.

Remedial actionn/a

AttributesAttribute Value

Severity Indeterminate

FormatCOMD08AB * AIN510 <Date><Time><Seqno>RTS ACG State

The AIN ACG Functionality is now turned ON.

AIN510 81

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 82: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Date mmmdd Variable Indicates month and day

Time hh:mm:ss Variable Indicates hour, minute, second

Seqno nnnn Variable the sequence number of this report

Active message exampleCOMD08AB * AIN510 Feb01 14:29:08 0600 RTS ACG State

The AIN ACG Functionality is now turned ON.

Clear message examplen/a

Associated OM registers

AIN511The advanced intelligent network (AIN) subsystem generates AIN511when operating company personnel disable automatic call gapping (ACG).

This report indicates the date and time when operating company personneldisabled ACG.

Log AIN511 applies to AIN Essentials and subsequent releases.

Disable ACG with the ACGONOF command in the AINCI tool.

Remedial actionn/a

AttributesAttribute Value

Severity Indeterminate

FormatCOMD08AB * AIN511 <Date><Time><Seqno>OFFL ACG State

The AIN ACG Functionality is now turned OFF.

82 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 83: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Date mmmdd Variable Indicates month and day

Time hh:mm:ss Variable Indicates hour, minute, second

Seqno nnnn Variable the sequence number of this report

Active message exampleCOMD08AB * AIN511 Feb01 14:29:13 0602 OFFL ACG State

The AIN ACG Functionality is now turned OFF.

Clear message examplen/a

Associated OM registers

AIN600The system generates the AIN600 log when the TstQuery tool sends amessage to the service control point (SCP). Operating company personnelgenerate the send command from the query tool at the TSTQUERY levelof the MAP terminal. The AIN600 log records an attempt to send amessage to the SCP. When the system finds errors or responses, thesystem generates additional reports in AIN601 and AIN602 logs.

Release history

NA017

This log is modified to support the new messages and parametersintroduced by feature AIN Timeout and Disconnect, (59037100).

Remedial actionn/a

AttributesAttribute Value

Severity Warning

Format<loadname>AIN600 <date><time><sequence no>INFO Test Query

Attempt

AIN600 83

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 84: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

User Name: <>

SessionID: <>

Application: <>

T1 Timer: <>

Transport: <>

Gtt Name: <>

Gtt Source: <>

Message: <>

<Parameters>

Selected field descriptionsField Value Fixed or

VariableDescription

User Name local datafill Variable This field is the name of the MAP CIuser (for example, TEAM11)

SessionID 0 to 32 767 Variable This field is the number identificationof the session.

Application R01, R02 Variable This field is the message set in use(for example, AIN Service Enablers).

T1 Timer 1-99 Variable This field is the preset time to wait foran incoming message.

Transport SS7, TCPIP Variable This field is the transport type used.

GTT Name local datafill Variable This field is the global title translationname used for signaling connectioncontrol point (SCCP) routing.

GTT Source local datafill Variable This field is the global title translationname source (for example, charge ordefault)

Message messages and of theAIN Essentialsmessage set

Variable This field is the message of the AINEssentials message set.

< parameters > parameters that gowith the outgoingmessages, parameterfield names and theirvalues

Variable This field is the values filled in theoutgoing message parameters.

84 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 85: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleCOMIO9BC AIN600 JAN02 15:50:40 9900 INFO Test Query Attempt

User Name: ADMIN

SessionID: 12527

Application: R02

T1 Timer: 30

Transport: TCPIP

Application Instance Number: 0

Message: Info_Collected

BearerCapability: speech

UserId Dn: 6137225085

Clear message examplen/a

Associated OM registers

AIN601The system generates the AIN601 log when operating company personnelissue the send command to the service control point (SCP) and receive anConnect To Resource (CTR) message from SCP as a response. Operatingcompany personnel generate the send command from the query tool at theTSTQUERY level of the MAP terminal. When the system finds errors orresponses, the system generates additional reports.

Release history

NA017

This log is modified to support the new meassages and parametersintroduced by feature AIN Timeout and Disconnect, (59037100). Also,AIN601 Log sends a CTR message from SCP as a response (59037140).

Remedial actionn/a

AIN601 85

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 86: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

Format<loadname>AIN601 <date><time><sequence no>INFO Test QueryResponse

User Name: <>

SessionID: <>

Elapsed Time Between Query And Response:

<Min>minute(s) <Sec>second(s) <mill>millisecond(s)

Conversation: <>

Trans ID: <>

Far End Trans ID: <>

Corr ID: <>

SCP Response Message: <>

<Parameters>

Selected field descriptionsField Value Fixed or

VariableDescription

UserName local datafill Variable This field is the name of the MAP CIuser (for example, TEAM11)

SessionID 0 to 32 767 Variable This field is the number identificationof the session.

ElapsedTimeBetweenQuery andResponse

see subfields Variable This field is the elapsed time betweenthe query and the response.

< Min > 0 to 32 767 Variable This field is the number of minutesthat elapsed between the query andthe response.

< Sec > 0 to 32 767 Variable This field is the number of secondsthat elapsed between the query andthe response.

86 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 87: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

< Mill > 0 to 32 767 Variable This field is the number ofmilliseconds that elapsed between thequery and the response.

Conversation Yes, No Variable This field indicates if the message is aconversation.

Trans ID 0 to 65 535 Variable This field is the transaction ID.

FarEndTransID 0 to 65 535 Variable When the incoming message is aconversation, this field is the SCPtransaction ID for the conversation.

Variable When the incoming message is aresponse, there is no SCP transactionID and this value is the serviceswitching point (SSP) transaction ID.

CorrID 0 to 255 Variable This field contains a correlation IDfrom the incoming transactioncapabilities application part (TCAP)message. The ID is the invoke ID.

CTR Message incoming messages Variable This field is the SCP response.

< parameters > incoming messageparameters

Variable This field is the value filled in theoutgoing message parameter.

Active message exampleCOMIO9BC AIN601 JAN02 15:50:40 0000 INFO Test Query Response

User Name: ADMIN

SessionID: 12527

Elapsed Time Between Query And Response:

0 minute(s) 0 second(s) 303 millisecond(s)

Conversation: No

Trans ID: 2

Far End Trans ID: 65021

Corr ID: 1

SCP Response Message: Analyze_Route

Called Party ID: 7225031

AIN601 87

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 88: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Nature of Number: Subscriber number

Numbering Plan: ISDN Numbering Plan

AMA SLP ID: 123456789

Clear message examplen/a

Associated OM registers

AIN602The system generates the AIN602 log when operating company personneluse the send command and find a send error. Operating companypersonnel generate the send command from the query tool at theTSTQUERY level of the MAP terminal. The AIN602 log indicates that thesystem found an error and did not send the message to the service controlpoint (SCP).

Remedial actionn/a

AttributesAttribute Value

Severity Warning

Format<loadname>AIN602 <date><time><sequence no>INFO Test QueryError

<Error Message>

User Name: <>

SessionID: <>

Application: <>

Transport: <>

GTT Name: <>

GTT Source: <>

Message: <>

88 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 89: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

T1 Timer: <>

Selected field descriptionsField Value Fixed or

VariableDescription

< ErrorMessage > No data in query tothe SCP, Unexpecteddata encountered,Invalid event ID ortransaction IDencountered, Invalidparametersencountered, Theapplication subsystemdoes not exist, NoTCAP transaction IDsavailable, Applicationout of Service,Unrecognized GameInterface Return Code

Variable This field is the description of the errormessages received from themessaging interface.

User Name local datafill Variable This field is the MAP CI user (forexample, TEAM11).

SessionID 0 to 32 767 Variable This field is the number identificationof the session.

Application R01, R02 Variable This field is the message set in use(for example, AIN Service Enablers).

Transport SS7, TCPIP Variable This field is the transport type used tosend the messages.

GTT Name local datafill Variable This field is the global title translationname used for signaling connectioncontrol part (SCCP) routing.

GTT Source local datafill Variable This field is the GTT name source (forexample, charge or default).

Application InstanceNumber

local datafill Variable This field is the number of theapplication instance (for example, 0).

Message Outgoing messages Variable This field is the outgoing message.

T1 Timer 0-99 Variable This field is the set time to wait for anincoming message.

Active message exampleCOMIO9BC AIN602 JAN02 15:50:40 9900 INFO Test Query Error

<Unable to send a query due to transport out of service>

AIN602 89

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 90: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

User Name: ADMIN

SessionID: 12527

Application: R02

Transport: TCPIP

Application Instance Number: 0

Message: Info_Collected

BearerCapability: speech

UserId Dn: 6137225085

T1 Timer: 30

Clear message examplen/a

Associated OM registers

AIN610The advanced intelligent network (AIN) subsystem generates log AIN610when an ACG control list changes. Changes include the addition orreplacement of a control. Log AIN610 indicates the contents of the control,the affected list, and when the addition or the replacement of a controloccurred.

Log AIN610 report applies to AIN Essentials and later releases.

Use table LOGCLASS to threshold or suppress the report of this log.

Remedial actionUse this report to monitor control list activity or for security purposes.

AttributesAttribute Value

Severity Warning

Formatoffice AIN610 mmmdd hh:mm:ss seqno INFO ACG/SOCC

90 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 91: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Control List Change

AIN ACG Control List Change

Change_Event: <>List_Type: <>

GTA: <>Duration (10 msec): <>

TT_Name: <>Interval (10 msec): <>

Selected field descriptionsField Value Fixed or

VariableDescription

List_Type SCP or SMS Variable indicates the following:

• SCP control list for automaticcontrols

• SMS control list for manualcontrols

Change_Event CONTROL ADDED orCONTROLREPLACED

Variable indicates when the control was anaddition to the specified list or areplacement of a current control in thelist

GTA NPANXXXXXX Variable the global title address indicates thecall or charge number to gap querieson

TT_Name As entered in tableC7GTTYPE, fieldGTTNAME

Variable the translation type name can indicatea service, a group of services, or asoftware release, depending on theentry

Duration numeric Variable indicates the gap duration in 10-msunits

Interval numeric Variable indicates the gap interval in 10-msunits

Active message exampleCOMD05AJ AIN610 JAN01 21:31:44 4624 INFO ACG/SOCC

Control List Change

AIN ACG Control List Change

Change_Event: CONTROL ADDED

GTA: 613621

AIN610 91

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 92: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

TT_Name: AINJAZZ

List_Type: SCP

Duration (10 msec): 6400

Interval (10 msec): 400

Clear message examplen/a

Associated OM registers

AIN611The advanced intelligent network (AIN) subsystem generates log AIN611when AIN removes a control from the indicated ACG control list. LogAIN611 generates this report when the AIN subsystem removes a controlthat uses one of the following removal messages:

• service control point (SCP)

• service management system (SMS) removal messages

• service switching point (SSP) delete command

The system does not generate this report when a control expires.

This log report is for AIN Essentials and later releases.

Use table LOGCLASS to threshold or suppress the report of this log.

Remedial actionUse this report to monitor control list activity or for security purposes.

AttributesAttribute Value

Severity Warning

Formatoffice AIN611 mmmdd hh:mm:ss seqno INFO ACG/SOCC Control

Removed

92 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 93: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AIN ACG control removed from list.

List_Type: <>

GTA: <>TT_Name: <>

Selected field descriptionsField Value Fixed or

VariableDescription

GTA NPANXXXXXX Variable Global title address, indicates the callor charge number to gap queries on.

TT_Name As entered in tableC7GTTYPE, fieldGTTNAME

Variable Translation type name. This field canindicate a service, a group of services,or a software release, depending onentry.

List_Type SCP or SMS Variable Indicates:

• SCP control list for automaticcontrols

• SMS control list for manualcontrols

Active message exampleCOMD05AJ AIN611 JAN01 21:50:27 7646 INFO ACG/SOCC

Control Removed

AIN ACG control removed from list.

List_Type: SCP

GTA: 613621 TT_Name: AINJAZZ

Clear message examplen/a

Associated OM registers

AIN612Log AIN612 indicates when the service control point (SCP) control list orservice management system (SMS) control list (or both) have beenrestored (controls removed) as requested. Log AIN612 is generated whencontrols are removed, either as a result of the service switching point(SSP) receiving an ACG_Global_Ctrl_Restore message from the SCP, orwhen the SSP restore command ACGRESTORE is invoked.

AIN612 93

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 94: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatCOMD08AJ AIN612 mmmdd hh:mm: ss ssdd INFO ACG/SOCC ControlList Restored

AIN ACG Control List Restored.

List Type: <>Request Type: <>

Number of Controls Deleted: <>

Source: <>

Selected field descriptionsField Value Fixed or

VariableDescription

Date: mmmdd Variable the date that the log is generated

Time: hh:mm:ss Variable the time that the log is generated

Seqno: ssdd Variable the sequence number of the log

List_Type SCP or SMS or SCPand SMS

Variable SCP or SMS or SCP and SMS ControlLists

Request_Type All or Exclude Zero-gap SMS Controls

Variable all controls are removed or all butzero-gap controls are removed (SMSonly)

Source SSP, SCP; PC:nnn-nnn-nnn, SSN:xxx

Variable SSP-initiated (AINCI, ACGRESTOREcommand) or SCP-initiated restoreusing ACG_Global_Ctrl_Restoremessage (where nnn and xxx arenumbers from 0-255, representing thepoint code (PC) and the signalingsubsystem number (SSN) of the SCPthat initiated the restore request

Number of ControlsDeleted

0-512 Variable the total number of controls removedfrom the control list(s)

Active message exampleCOMD08AJ AIN612 JAN01 21:50:27 7646 INFO ACG/SOCC

94 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 95: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Control List Restored

AIN ACG Control List Restored.

List_Type: SMS Request_Type: Exclude Zero-Gap SMS

Controls

Number of Controls Deleted: 45

Source: SCP; PC: 100-105-106, SSN:51

COMD08AJ AIN612 JAN601 14:50:00 7646 INFO ACG/SOCC

Control List Restored

AIN ACG Control List Restored.

List_Type: SCP Request_Type: All

Number of Controls Deleted: 10

Source: SSP

Clear message examplen/a

Associated OM registers

AINT700 Format 1The system generates the AINT700 log when the AINTrace tool finds aCTR and CTR clear messages related to the agent or to select messages.The AINT700 log records the CTR messages, and displays the messagesin the following formats: TEXT, HEX, and BOTH (TEXT and HEX).

Release history

NA017

This log is modified to support the new messages and parametersintroduced by feature AIN Timeout and Disconnect, (59037100). Also,AINT700 Log records the CTR messages, and displays the message in thefollowing formats: TEXT, HEX, and BOTH (TEXT and HEX), (59037140).

Remedial actionn/a

AINT700 Format 1 95

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 96: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

Formatloadname>AINT700 <date><time><sequence no>INFO AINTraceReport

TCAP message recorded by AINTRACE:

Time:<>

Direction<>

****TCAP message in HEX format ****

<sequence of hex bytes>

Selected field descriptionsField Value Fixed or

VariableDescription

TID two hexadecimalnumbers

Variable This field is the TID of the message.

Agent value depends on theagent

Variable This field is the agent of the message.

Direction from SCP or Adjunct(incoming), from SSP(outgoing)

Variable This field is the direction of themessage.

Hex message Hexadecimal Variable This field is the contents of themessage in hexadecimal and textform.

Text message Text Variable This field is the contents of themessage in text form.

Hex and textmessage

Hexadecimal and text Variable This field is the contents of themessage in hexadecimal and textform.

TCAP package type Unidirectional, Querywith Permission,Query WithoutPermission,Response,Conversation With

Variable This field is the package type of themessage.

AIN does not allow the followingpackage types: Query WithoutPermission, Conversation WithoutPermission.

96 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 97: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Permission,Conversation WithoutPermission, Abort

Origin ID numerical Variable This field is the originator of themessage.

Respond ID numerical Variable This field is the responder of themessage.

Component Type Invoke (Last), ReturnResult (Last), ReturnError, Reject, Invoke(Not Last), ReturnResult (Not Last)

Variable This field is the component type of themessage.

AIN does not allow the Return Result(Not Last) component.

Component ID numerical Variable This field is the componentidentification of the message.

Invoke ID numerical Variable This field is the invoke identification ofthe message.

Correlation ID numerical Variable This field is the correlationidentification of the message.

< Operation Code > a valid operation code Variable This field is the operation code of themessage.

< parameters > valid parameter(s),their field names andtheir values

Variable This field is the value of theparameter(s).

Active message exampleThe following example, in HEX format, represents an AINT700log report for a T_Busy query.

COML013AM AINT700 OCT20 20:21:07 9100 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 99/10/20 20:21:07 Tid: 74 316

Agent: HOST 00 1 09 27 DN 6136210307

Direction: from SSP (outgoing)

***** TCAP message in HEX format *****

E2 4D C7 04 00 00 60 00 E8 45 E9 43 CF 01 00

D1 02 64 06 30 3A BF 35 07 81 05 16 73 22 70

AINT700 Format 1 97

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 98: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

70 8D 01 00 8F 07 01 10 16 73 22 70 70 9F 34

01 1A 93 07 03 10 16 63 12 30 70 92 07 03 13

16 63 12 30 70 94 01 00 8E 02 82 91 9F 5E 01

01 90 01 00

The following example, in HEX format, represents an AINT700log report for an Offer_Call response.

COML013AM AINT700 OCT20 20:21:07 9300 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 99/10/20 20:21:07 Tid: 74 316

Agent: HOST 00 1 09 27 DN 6136210307

Direction: from SCP or Adjunct (incoming)

E4 44 C7 04 00 00 60 00 E8 3C E9 3A CF 02 01 00

00 D1 02 65 04 30 30 92 07 00 00 16 63 12 03

60 98 01 42 BA 22 8B 0A 36 31 33 37 37 37 38

37 37 37 8D 0A 48 45 4C 4C 4F 2C 20 44 41 44

93 08 30 31 30 31 30 30 30 30

The following example, in HEX format, represents an AINT700log report for Automatic Call Gapping (ACG).

COML013AM AINT700 OCT20 20:46:26 0100 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 99/10/20 20:46:26

Direction: form SCP or Adjunct (incoming)

***** TCAP message in HEX format *****

E1 28 C7 00 E8 24 E9 22 CF 02 01 00 D1 02 69

01 30 18 9F 3B 01 4A 9F 3E 01 0D 9F 3F 01 0D

98 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 99: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

9F 46 01 0F 9F 45 05 16 63 12 34 01

The following example, in HEX format, represents an AINT700log report for an Update query.

COML013AM AINT700 OCT20 20:51:03 8300 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 99/10/20 20:51:03

Direction: from SCP or Adjunct (incoming)

***** TCAP message in HEX format *****

E2 26 C7 04 00 00 E0 00 E8 1E E9 1C CF 01 02

D1 02 68 03 30 13 BF 67 10 A1 0A 85 08 4C 6F

63 53 53 50 49 44 9F 5B 01 78

The following example, in HEX format, represents an AINT700log report for an Update_success response.

COML013AM AINT700 OCT20 20:51:03 8500 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 99/10/20 20:51:03

Direction: from SSP (outgoing)

***** TCAP message in HEX format *****

E4 0F C7 04 00 00 E0 00 E8 07 EA 05 CF 01 02

30 00

The following example, in HEX format, represents an AINT700log report for Create_Call.

COMR13AY AINT700 JAN05 11:33:01 9400 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 00/01/05 11:33:01

Direction: from SCP or Adjunct (incoming)

AINT700 Format 1 99

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 100: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

***** TCAP message in HEX format *****

E2 25 C7 04 00 00 00 BB E8 1D E9 1B CF 01 01

D1 02 65 07 30 12 8F 07 03 10 16 63 12 17 73

92 07 03 13 16 63 12 17 05

Clear message examplen/a

Associated OM registers

AINT700 Format 2Refer to AINT700. This examples in this format of AINT700 show TEXTformat logs (as opposed to HEX or BOTH format).

Release history

NA017

This log is modified to support the new messages and parametersintroduced by feature AIN Timeout and Disconnect, (59037100). Also,AINT700 Log records the CTR messages, and displays the message in thefollowing formats: TEXT, HEX, and BOTH (TEXT and HEX), (59037140).

Remedial actionn/a

AttributesAttribute Value

Severity Warning

Format<loadname>AINT700 <date><time><sequence no>INFO AINTraceReport

TCAP message recorded by AINTRACE:

Time: <>

Direction: <>

****TCAP message in TEXT format ****

100 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 101: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

TCAP Package Type: <>

Origin ID: <>

Respond ID: <>

Component Sequence:

===================

Component: <>

Component Type: <>

Invoke ID: <>

Correlation ID: <>

Operation Code

Operation Family: <>

Operation Name: <>

====Parameter Sequence====

<Parameter Name>

<Parameter Fields>

Selected field descriptionsField Value Fixed or

VariableDescription

Invoke ID numerical Variable This field is the invoke identification ofthe message.

Correlation ID numerical Variable This field is the correlationidentification of the message.

< Operation Code > a valid operation code Variable This field is the operation code of themessage.

< parameters > valid parameter(s),their field names andtheir values

Variable This field is the value of theparameter(s).

TID two hexadecimalnumbers

Variable This field is the TID of the message.

Agent value depends on theagent

Variable This field is the agent of the message.

AINT700 Format 2 101

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 102: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Direction from SCP or Adjunct(incoming), from SSP(outgoing)

Variable This field is the direction of themessage.

Hex message Hexadecimal Variable This field is the contents of themessage in hexadecimal and textform.

Text message Text Variable This field is the contents of themessage in text form.

Hex and textmessage

Hexadecimal and text Variable This field is the contents of themessage in hexadecimal and textform.

TCAP package type Unidirectional, Querywith Permission,Query WithoutPermission,Response,Conversation WithPermission,Conversation WithoutPermission, Abort

Variable This field is the package type of themessage.

AIN does not allow the followingpackage types: Query WithoutPermission, Conversation WithoutPermission.

Origin ID numerical Variable This field is the originator of themessage.

Respond ID numerical Variable This field is the responder of themessage.

Component Type Invoke (Last), ReturnResult (Last), ReturnError, Reject, Invoke(Not Last), ReturnResult (Not Last)

Variable This field is the component type of themessage.

AIN does not allow the Return Result(Not Last) component.

Component ID numerical Variable This field is the componentidentification of the message.

Active message exampleThe following example, in TEXT format, represents an AINT700log report for a T_Busy query.

COML013AM AINT700 OCT20 20:21:07 9100 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 99/10/20 20:21:07 Tid: 74 316

Agent: HOST 00 1 09 27 DN 6136210307

102 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 103: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Direction: from SSP (outgoing)

***** TCAP message in TEXT format *****

TCAP Package Type: Query with Permission

Origin ID: 00 00 60 00

Respond ID: NIL

Component Sequence

=================

COMPONENT: 1

Component Type: Invoke (last) Component

Invoke ID: 0

Correlation ID: 256

Operation Code

Operation Family: Request Instructions

Operation Name: T-Busy

The following example, in TEXT format, represents an AINT700log report for an Offer_Call response.

COML013AM AINT700 OCT20 20:21:07 9300 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 99/10/20 20:21:07 Tid: 74 316

Agent: HOST 00 1 09 27 DN 6136210307

Direction: from SCP or Adjunct (incoming)

***** TCAP message in TEXT format *****

TCAP Package Type: Response

Origin ID: NIL

Respond ID: 00 00 60 00

AINT700 Format 2 103

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 104: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Component Sequence

=================

COMPONENT: 1

Component Type: Invoke (last) Component

Invoke ID: 1

Correlation ID: 0

Operation Code

Operation Family: Connection Control

Operation Name: Offer_Call

====Parameter Sequence====

CallingPartyID: 6136213006

Nature of Number: Unknown or not applicable

Numbering Plan: Unknown or not applicable

Presentation Indicator: Presentation allowed

Screen Indicator: User provided, not screened

Odd/Even Indicator: Even digits

ControllingLegTreatment:alertingOnPattern2DistinctiveSpecial

DisplayText:

callingAddress: "6137778777"

callingPartyName: "HELLO, DAD"

dateTimeOfDay: "01010000"

The following example, in TEXT format, represents an AINT700log report for Automatic Call Gapping (ACG).

COML013AM AINT700 OCT20 20:46:26 0100 INFO AINTrace Report

TCAP Message recorded by AINTrace:

104 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 105: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Time: 99/10/20 20:46:26

Direction: from SCP or Adjunct (incoming)

***** TCAP message in TEXT format *****

TCAP Package Type: Unidirectional

Origin ID: NIL

Respond ID: NIL

Component Sequence

=================

COMPONENT: 1

Component Type: Invoke (last) Component

Invoke ID: 1

Correlation ID: 0

Operation Code

Operation Family: Network Management

Operation Name: ACG

====Parameter Sequence====

ControlCauseIndicator:

Control Digits: 10 digit control

SMS Indicator: SMS initiated controls encountered

SCP Indicator: no SCP overload controls encountered

GapDuration: infinity

NationalGapInterval: no300Seconds

Translation Type: AINPOP - internetwork applications - 15

GlobalTitleValue: 6136214310

AINT700 Format 2 105

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 106: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The following example, in TEXT format, represents an AINT700log report for an Update query.

COML013AM AINT700 OCT20 20:51:03 8300 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 99/10/20 20:51:03

Direction: from SCP or Adjunct (incoming)

***** TCAP message in TEXT format ***** TCAP Package Type:

Query with Permission

Origin ID: 00 00 E0 00

Respond ID: NIL

Component Sequence

==================

COMPONENT: 1

Component Type: Invoke (last) Component

Invoke ID: 2

Correlation ID: 256

Operation Code

Operation Family: Information Revision

Operation Name: Update

====Parameter Sequence====

SSPUserResource:

SSPUserResourceID:

LocalSSPID: LocSSPID

ONoAnswerTimer: 120

--{ End of SSPUserResource }--

106 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 107: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The following example, in TEXT format, represents an AINT700log report for an Update_success response.

COML013AM AINT700 OCT20 20:51:03 8500 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 99/10/20 20:51:03

Direction: from SSP (outgoing)

***** TCAP message in TEXT format *****

TCAP Package Type: Response

Origin ID: NIL

Respond ID: 00 00 E0 00

Component Sequence

==================

COMPONENT: 1

Component Type: Result (last) Component

CORR ID: 2

*** No parameters in the message ***

The following example, in TEXT format, represents an AINT700log report for Create_Call.

COMR13AY AINT700 JAN05 11:33:01 9400 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 00/01/05 11:33:01

Direction: from SCP or Adjunct (incoming)

***** TCAP message in TEXT format *****

TCAP Package Type: Query with Permission

Origin ID: 00 00 00 BB

AINT700 Format 2 107

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 108: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Respond ID: NIL

Component Sequence

=================

COMPONENT: 1

Component code: E9

Component Type: Invoke (last) Component

Invoke ID: 1

Correlation ID: 256

Operation Code

Opcode Bytes: 65 07

Operation Family: Connection Control

Operation Name: Create_Call

Parameter Tag: 30

====Parameter Sequence====

Parameter Id: 8F

Contents: 03 10 16 63 12 17 73

CalledPartyID: 6136217137

Nature of Number: National (significant) number

Numbering Plan: ISDN Numbering Plan

Odd/Even Indicator: Even digits

Parameter Id: 92

Contents: 03 13 16 63 12 17 05

CallingPartyID: 6136217150

Nature of Number: Unique national (significant) number

108 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 109: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Numbering Plan: ISDN Numbering Plan

Presentation Indicator: Presentation allowed

Screen Indicator: Network provided

Odd/Even Indicator: Even digits

Clear message examplen/a

Associated OM registers

AINT700 Format 3Refer to AINT700. This examples in this format of AINT700 show BOTHformat logs (as opposed to HEX or TEXT format).

Release history

NA017

This log is modified to support the new messages and parametersintroduced by feature AIN Timeout and Disconnect, (59037100). Also,AINT700 Log records the CTR messages, and displays the message in thefollowing formats: TEXT, HEX, and BOTH (TEXT and HEX), (59037140).

Remedial actionn/a

AttributesAttribute Value

Severity • Warning

• Critical

Format<loadname>AINT700 <date><time><sequence no>INFO AINTraceReport

TCAP message recorded by AINTRACE:

Time: <>

Direction <>

AINT700 Format 3 109

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 110: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

****TCAP message in HEX format ****

<sequence of hex bytes>

****TCAP message in TEXT format ****

TCAP Package Type <>

Origin ID:

Respond ID: <>

Component Sequence

==================

Component:

Component Type: <>

Invoke ID: <>

Correlation ID: <>

Operation Code

Operation Family: <>

Operation Name: <>

====Parameter Sequence====

<Parameter Name>

<Parameter Fields>

Selected field descriptionsField Value Fixed or

VariableDescription

TID two hexadecimalnumbers

Variable This field is the TID of the message.

Agent value depends on theagent

Variable This field is the agent of the message.

Direction from SCP or Adjunct(incoming), from SSP(outgoing)

Variable This field is the direction of themessage.

110 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 111: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Hex message Hexadecimal Variable This field is the contents of themessage in hexadecimal and textform.

Text message Text Variable This field is the contents of themessage in text form.

Hex and textmessage

Hexadecimal and text Variable This field is the contents of themessage in hexadecimal and textform.

TCAP package type Unidirectional, Querywith Permission,Query WithoutPermission,Response,Conversation WithPermission,Conversation WithoutPermission, Abort

Variable This field is the package type of themessage.

AIN does not allow the followingpackage types: Query WithoutPermission, Conversation WithoutPermission.

Origin ID numerical Variable This field is the originator of themessage.

Respond ID numerical Variable This field is the responder of themessage.

Component Type Invoke (Last), ReturnResult (Last), ReturnError, Reject, Invoke(Not Last), ReturnResult (Not Last)

Variable This field is the component type of themessage.

AIN does not allow the Return Result(Not Last) component.

Component ID numerical Variable This field is the componentidentification of the message.

Invoke ID numerical Variable This field is the invoke identification ofthe message.

Correlation ID numerical Variable This field is the correlationidentification of the message.

< Operation Code > a valid operation code Variable This field is the operation code of themessage.

< parameters > valid parameter(s),their field names andtheir values

Variable This field is the value of theparameter(s).

Active message exampleThe following example, in BOTH format, represents an AINT700log report for a T_Busy query.

AINT700 Format 3 111

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 112: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

COML013AM AINT700 OCT20 20:21:07 9100 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 99/10/20 20:21:07 Tid: 74 316

Agent: HOST 00 1 09 27 DN 6136210307

Direction: from SSP (outgoing)

***** TCAP message in HEX format *****

E2 4D C7 04 00 00 60 00 E8 45 E9 43 CF 01 00

D1 02 64 06 30 3A BF 35 07 81 05 16 73 22 70

70 8D 01 00 8F 07 01 10 16 73 22 70 70 9F 34

01 1A 93 07 03 10 16 63 12 30 70 92 07 03 13

16 63 12 30 70 94 01 00 8E 02 82 91 9F 5E 01

01 90 01 00

***** TCAP message in TEXT format *****

TCAP Package Type: Query with Permission

Origin ID: 00 00 60 00

Respond ID: NIL

Component Sequence

=================

COMPONENT: 1

Component code: E9

Component Type: Invoke (last) Component

Invoke ID: 0

Correlation ID: 256

Operation Code

112 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 113: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Opcode Bytes: 64 06

Operation Family: Request Instructions

Operation Name: T-Busy

Parameter Tag: 30

====Parameter Sequence====

Parameter Id: BF 35

Contents: 81 05 16 73 22 70 70

UserID:

DN: 6137220707

--{ End of UserID }--

Parameter Id: 8D

Contents: 00

BearerCapability: speech

Parameter Id: 8F

Contents: 01 10 16 73 22 70 70

CalledPartyID: 6137220707

Nature of Number: Subscriber number

Numbering Plan: ISDN Numbering Plan

Odd/Even Indicator: Even digits

Parameter Id: 9F 34

Contents: 1A

TriggerCriteriaType: tBusy

Parameter Id: 93

Contents: 03 10 16 63 12 30 70

AINT700 Format 3 113

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 114: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

ChargeNumber: 6136210307

Nature of Number: ANI of the calling party; national number

Numbering Plan: ISDN Numbering Plan

Odd/Even Indicator: Even digits

Parameter Id: 92

Contents: 03 13 16 63 12 30 70

CallingPartyID: 6136210307

Nature of Number: Unique national (significant) number

Numbering Plan: ISDN Numbering Plan Presentation Indicator:Presentation allowed

Screen Indicator: Network provided

Odd/Even Indicator: Even digits

Parameter Id: 94

Contents: 00

ChargePartyStationType: IdentifiedLine - No SpecialTreatment

Parameter Id: 8E

Contents: 82 91

BusyCause:

General location: Public network serving the local user

Coding Standard: CCITT Standard

Number Of Diags: 0

Cause value: Normal event - User busy

Diagnostic Byte #1: 242

Diagnostic Byte #2: 54

114 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 115: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Parameter Id: 9F 5E

Contents: 01

BusyType: Call Cannot Be Offered

Parameter Id: 90

Contents: 00

CalledPartyStationType: IdentifiedLine - No SpecialTreatment

The following example, in BOTH format, represents an AINT700log report for an Offer_Call response.

COML013AM AINT700 OCT20 20:21:07 9300 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 99/10/20 20:21:07 Tid: 74 316

Agent: HOST 00 1 09 27 DN 6136210307

Direction: from SCP or Adjunct (incoming)

***** TCAP message in HEX format *****

E4 44 C7 04 00 00 60 00 E8 3C E9 3A CF 02 01

00 D1 02 65 04 30 30 92 07 00 00 16 63 12 03

60 98 01 42 BA 22 8B 0A 36 31 33 37 37 37 38

37 37 37 8D 0A 48 45 4C 4C 4F 2C 20 44 41 44

93 08 30 31 30 31 30 30 30 30

***** TCAP message in TEXT format *****

TCAP Package Type: Response

Origin ID: NIL

Respond ID: 00 00 60 00

Component Sequence

AINT700 Format 3 115

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 116: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

=================

COMPONENT: 1

Component code: E9

Component Type: Invoke (last) Component

Invoke ID: 1

Correlation ID: 0

Operation Code

Opcode Bytes: 65 04

Operation Family: Connection Control

Operation Name: Offer_Call

Parameter Tag: 30

====Parameter Sequence====

Parameter Id: 92

Contents: 00 00 16 63 12 03 60

CallingPartyID: 6136213006

Nature of Number: Unknown or not applicable

Numbering Plan: Unknown or not applicable

Presentation Indicator: Presentation allowed

Screen Indicator: User provided, not screened

Odd/Even Indicator: Even digits

Parameter Id: 98

Contents: 42

ControllingLegTreatment:alertingOnPattern2DistinctiveSpecial

Parameter Id: BA

116 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 117: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Contents:

8B 0A 36 31 33 37 37 37 38 37 37 37 8D 0A 48

45 4C 4C 4F 2C 20 44 41 44 93 08 30 31 30 31

30 30 30 30

DisplayText:

callingAddress: "6137778777"

callingPartyName: "HELLO, DAD"

dateTimeOfDay: "01010000"

ControllingLegTreatment:alertingOnPattern2DistinctiveSpecial

Parameter Id: BA

Contents: 8B 0A 36 31 33 37 37 37 38 37 37 37 8D 0A 48

45 4C 4C 4F 2C 20 44 41 44 93 08 30 31 30 31

30 30 30 30

DisplayText:

callingAddress: "6137778777"

callingPartyName: "HELLO, DAD"

dateTimeOfDay: "01010000"

The following example, in BOTH format, represents an AINT700log report for Automatic Call Gapping (ACG).

COML013AM AINT700 OCT20 20:46:26 0100 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 99/10/20 20:46:26

Direction: from SCP or Adjunct (incoming)

***** TCAP message in HEX format *****

E1 28 C7 00 E8 24 E9 22 CF 02 01 00 D1 02 69

AINT700 Format 3 117

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 118: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

01 30 18 9F 3B 01 4A 9F 3E 01 0D 9F 3F 01 0D

9F 46 01 0F 9F 45 05 16 63 12 34 01

***** TCAP message in TEXT format *****

TCAP Package Type: Unidirectional

Origin ID: NIL

Respond ID: NIL

Component Sequence

=================

COMPONENT: 1

Component code: E9

Component Type: Invoke (last) Component

Invoke ID: 1

Correlation ID: 0

Operation Code

Opcode Bytes: 69 01

Operation Family: Network Management

Operation Name: ACG

Parameter Tag: 30

====Parameter Sequence====

Parameter Id: 9F 3B

Contents: 4A

ControlCauseIndicator:

Control Digits: 10 digit control

SMS Indicator: SMS initiated controls encountered

118 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 119: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

SCP Indicator: no SCP overload controls encountered

Parameter Id: 9F 3E

Contents: 0D

GapDuration: infinity

Parameter Id: 9F 3F

Contents: 0D

NationalGapInterval: no300Seconds

Parameter Id: 9F 46

Contents: 0F

Translation Type: AINPOP - internetwork applications - 15

Parameter Id: 9F 45

Contents: 16 63 12 34 01

GlobalTitleValue: 6136214310

The following example, in BOTH format, represents an AINT700log report for an Update query.

COML013AM AINT700 OCT20 20:51:03 8300 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 99/10/20 20:51:03

Direction: from SCP or Adjunct (incoming)

***** TCAP message in HEX format *****

E2 26 C7 04 00 00 E0 00 E8 1E E9 1C CF 01 02

D1 02 68 03 30 13 BF 67 10 A1 0A 85 08 4C 6F

63 53 53 50 49 44 9F 5B 01 78

***** TCAP message in TEXT format *****

TCAP Package Type: Query with Permission

AINT700 Format 3 119

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 120: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Origin ID: 00 00 E0 00

Respond ID: NIL

Component Sequence

==================

COMPONENT: 1

Component code: E9

Component Type: Invoke (last) Component

Invoke ID: 2

Correlation ID: 256

Operation Code

Opcode Bytes: 68 03

Operation Family: Information Revision

Operation Name: Update

Parameter Tag: 30

====Parameter Sequence====

Parameter Id: BF 67

Contents: A1 0A 85 08 4C 6F 63 53 53 50 49 44 9F 5B 01

78

SSPUserResource:

SSPUserResourceID:

LocalSSPID: LocSSPID

The following example, in BOTH format, represents an AINT700log report for an Update_success response.

COML013AM AINT700 OCT20 20:51:03 8500 INFO AINTrace Report

TCAP Message recorded by AINTrace:

120 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 121: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Time: 99/10/20 20:51:03

Direction: from SSP (outgoing)

***** TCAP message in HEX format *****

E4 0F C7 04 00 00 E0 00 E8 07 EA 05 CF 01 02

30 00

***** TCAP message in TEXT format *****

TCAP Package Type: Response

Origin ID: NIL

Respond ID: 00 00 E0 00

Component Sequence

==================

COMPONENT: 1

Component code: EA

Component Type: Result (last) Component

CORR ID: 2

*** No parameters in the message ***

The following example, in BOTH format, represents an AINT700log report for Create_Call.

COMR13AY AINT700 JAN05 11:33:01 9400 INFO AINTrace Report

TCAP Message recorded by AINTrace:

Time: 00/01/05 11:33:01

Direction: from SCP or Adjunct (incoming)

***** TCAP message in HEX format *****

E2 25 C7 04 00 00 00 BB E8 1D E9 1B CF 01 01

D1 02 65 07 30 12 8F 07 03 10 16 63 12 17 73

AINT700 Format 3 121

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 122: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

92 07 03 13 16 63 12 17 05

***** TCAP message in TEXT format *****

TCAP Package Type: Query with Permission

Origin ID: 00 00 00 BB

Respond ID: NIL

Component Sequence

==================

COMPONENT: 1

Component code: E9

Component Type: Invoke (last) Component

Invoke ID: 1

Correlation ID: 256

Operation Code

Opcode Bytes: 65 07

Operation Family: Connection Control

Operation Name: Create_Call

Parameter Tag: 30

====Parameter Sequence====

Parameter Id: 8F

Contents: 03 10 16 63 12 17 73

CalledPartyID: 6136217137

Nature of Number: National (significant) number

Numbering Plan: ISDN Numbering Plan

Odd/Even Indicator: Even digits

122 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 123: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Parameter Id: 92

Contents: 03 13 16 63 12 17 05

CallingPartyID: 6136217150

Nature of Number: Unique national (significant) number

Numbering Plan: ISDN Numbering Plan

Presentation Indicator: Presentation allowed

Screen Indicator: Network provided

Odd/Even Indicator: Even digits

Clear message examplen/a

Associated OM registers

ALRM109The Alarm (ALRM) subsystem generates ALRM109 when the AlarmSending and Checking (ASCS) system is enabled or disabled. This alsooccurs at specified points of ASCS implementation. Refer to Alarm SystemDescription, 297-1001-122 for a description of ASCS. Refer to OfficeParameters Reference Manual for ASCS office parameters.

Remedial actionThere is no action required. Descriptions of the fields are important in theunderstanding of this log.

AttributesAttribute Value

Severity • Warning

• Critical

• Major

• Minor

FormatALRM109 mmmdd hh:mm:ss ssdd INFO ASCS ALARM SENDING&CHECKING

alrmtxt ; reastxt

ALRM109 123

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 124: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFO ASCS ALARMSENDING &CHECKING

Constant Fixed Indicates log report for alarm sendingand checking system (ASCS)

alrmtxt CRITICAL ALARM Variable Indicates critical alarm condition

MAJOR ALARM Variable Indicates major alarm condition

MINOR ALARM Variable Indicates minor alarm condition

NO ALARM Variable Indicates no alarm

reastxt ASCS OFF: SENDFACILITY DISABLED

Variable Indicates alarm transfer switch orcommand interpreter command (CI),ASCS OFF disables send facility

reastxt ASCS ON: SENDFACILITIESENABLED

Variable Indicates alarm transfer switch or CIcommand ASCS ON enabled sendfacility

CHECK_CALL MADE Variable Indicates operator made checking callto troubled office

SEND_CALLDISCONNECT

Variable Indicates alarm condition cleared andremains clear for required time. Exitmessage sent to disconnect SENDCALL.

SEND_CALL NOANSWER TIMEOUT

Variable Indicates maximum time systemallows to pass without answer fromoperator. System routes SEND CALLto different operator trunk if available.

SEND_CALLORIGINATION

Variable Indicates alarm detected and originalmessage sent to start-up SEND CALL

SEND_CALL ROUTEERROR

Variable Indicates system detected alarm butSEND CALL failed to establish routeto an operator

Active message exampleALRM109 APR01 12:00:00 2112 INFO ASCS ALARM SENDING&CHECKING

CRITICAL ALARM; ASCS ON: SEND FACILITIES ENABLED

Clear message examplen/a

124 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 125: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ALRM111The Alarm (ALRM) subsystem generates ALRM111 when an emergencyservice bureau (ESB) leaves a receiver off-hook for a designated period oftime. The ESB must leave the receiver off-hook for a specified period oftime before the system generates a report.

Remedial actionMake sure the receiver is back on-hook. Check for ALRM112 log report.

AttributesAttribute Value

Severity Indeterminate

Format* ALRM111 mmmdd hh:mm:ss ssdd TBL ESB OFF HOOK

len DN dn

Selected field descriptionsField Value Fixed or

VariableDescription

TBL ESB OFF HOOK Constant Fixed Indicates emergency service bureauleft receiver off-hook for designatedperiod of time

len Integers Variable Provides the line equipment number(LEN).

DN Integers Variable Provides the ten digit directorynumber (DN) for ESB line equipment.

Active message example*ALRM111 APR01 12:00:00 2112 TBL ESB OFF HOOK

HOST 00 0 00 01 DN 9096211235

Clear message examplen/a

ALRM111 125

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 126: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ALRM112The Alarm (ALRM) subsystem generates ALRM112 when an EmergencyService Bureau (ESB) line that caused an ALRM111 report before (ESBoff-hook) is back on-hook.

Remedial actionThere is no action required. This log must follow ALRM111 report.

AttributesAttribute Value

Severity • Warning

• Minor

FormatALRM112 mmmdd hh:mm:ss ssdd INFO ESB ON HOOK

len DN dn

Selected field descriptionsField Value Fixed or

VariableDescription

INFO ESB ON HOOK Constant Fixed Indicates emergency service bureauline that generated log reportALRM111 before is back on-hook.Minor alarm turned on by ALRM111switches off.

len Integers Variable Provides the line equipment number(LEN) for ESB.

DN Integers Variable Provides the ten digit directorynumber (DN) for ESB line equipment.

Active message exampleALRM112 APR01 12:00:00 2112 INFO ESB ON HOOK

HOST 00 0 00 02 DN 9096221234

Clear message examplen/a

126 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 127: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ALT100The Automatic Line Testing (ALT) subsystem generates the ALT100 logreport when a short diagnostic (SDIAG) test of line equipment fails. Thesystem performs ALT because of either a manual request from the ALTMAP level or because of the ALT schedule. See ALT MAP level forschedule.

Remedial actionTo isolate the fault, perform line diagnostics on the suspect line equipmentfrom the line test position (LTP) MAP level. Refer to the Lines MaintenanceGuide, 297-1001-594, for information on diagnostic tests for lineequipment. LINE100 or LINE101 logs are generated:

• If the LINE 100 log (line test pass) is generated but the ALT100 logcontinues to be generated during retests of ALT failures, contact thenext level of maintenance.

• If a LINE101 log (line test failure) is generated, follow "Action" in theLINE101 log report.

Continue to try to clear the fault until one of the following occurs:

• The system generates LINE100 log and not ALT100 log.

• Contact the next level of maintenance.

AttributesAttribute Value

Severity Indeterminate

FormatALT100 mmmdd hh:mm:ss ssdd FAIL ALT

len DN dn cycltxt

TEST TYPE SDIAG

Selected field descriptionsField Value Fixed or

VariableDescription

FAIL ALT Constant Fixed Indicates an automatic line test failed

len Alphanumeric textstring

Variable The line equipment number (LEN) forthe suspect line equipment

ALT100 127

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 128: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

DN Constant Fixed Indicates that a directory number (DN)follows

dn Integers Variable The directory number (DN) for thesuspect line equipment

cycltxt 1st CYCLE Variable Indicates the line equipment failed thespecified test the first time the testwas run

RETEST 1 Variable Indicates the line equipment failed thespecified test during the first automaticretest of the line equipment

RETEST 2 Variable Indicates the line equipment failed thespecified test during the secondautomatic retest of the line equipment

TEST TYPE SDIAG Constant Fixed Indicates a short diagnostic test wasperformed on suspect line equipment

Active message exampleALT100 APR01 12:00:00 2112 FAIL ALT

HOST 01 1 01 01 DN 8057811999 1st CYCLE

TEST TYPE SDIAG

Clear message examplen/a

Associated OM registers

ALT101The subsystem generates ALT101 when an extended diagnostic (DIAG)test of line equipment fails. ALT performs as a result of a manual requestfrom the ALT MAP level or according to the ALT schedule. Refer to theALT MAP level for schedule.

ALT performs on separate lines. Normally ALT performs on known groupsof lines. The DMS switch automatically retests each line that fails the firstrun of ALT. The switch also retests each line that fails during the secondrun of ALT.

The following references isolate and correct failures indicated by ALT101.For all failures related to entries, refer to the data schema section of theTranslations Guide.

128 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 129: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The following list describes the diagnostic results and lists the action totake for log report ALT101:

Addon Not Datafilled - Indicates system tested a circuit pack connected toa key set. An addon is not entered correctly in customer data TableKSETINV.

• Refer to the data schema section of the Translations Guide to correctKSETINV.

Addon Not Responding - Indicates system tested a circuit pack connectedto a key set. An addon entered in customer data Table KSETINV did notrespond to the test.

• Refer to the data schema section of the Translations Guide to correctKSETINV.

Audit in Progress - Indicates a line card audit is in progress.

• Retry the diagnostic.

Bad Wink From PSAP - Indicates public-safety answering point (PSAP)test failed at the ALT level of the MAP. A wink that is not normal receivedfrom the PSAP causes this failure. A wink duration shorter than or longerthan the allowed time interval characterizes a wink that is not normal.

• Check PSAP hardware.

Buffer Full Flag High - Indicates that circuit pack buffer is full. Testperforms after signal correctly loops to a key set. The buffer full flag stateremains HIGH This state prevents additional messaging from peripheralmodule (PM).

• Replace Card. Refer to the Lines Maintenance Guide for the correctprocedure.

Buffer Full Flag Low - Indicates that circuit pack buffer is not ready toreceive messages from PM. The circuit pack receives a PM request tosignal a key set. This part of the test performs. The buffer full flag stateremains LOW. This state prevents additional messaging from PM.

• Replace Card. Refer to the Lines Maintenance Guide for the correctprocedure.

Bus Extender - Indicates that the bus extender loopback test failed. Thetest consists of a tone sent from the RCU maintenance card to the busextender card. The tone loops and returns to the maintenance card foranalysis.

• Replace bus extender card (NT3A17).

ALT101 129

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 130: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Bypass Active - Indicates that the metal bypass is active.

• Attempt again.

CARD MISSING - Indicates request to test circuit pack was made. Packwas not present at suspect equipment location.

• Insert card. Refer to the Lines Maintenance Guide for the correctprocedure.

CARD OK,FACTST ABORT - Indicates circuit pack test completedcorrectly. Test aborted before the facility test completed.

• Manual test. Refer to the Lines Maintenance Guide for the correctprocedure.

CC - No Mailbox - Indicates that not enough software resources areavailable to perform test.

• Attempt again. Refer to the Lines Maintenance Guide for the correctprocedure.

nnnn nnnn nnnn nnnn CHANNEL LOSS - Indicates that the channel losssubtest of the extended diagnostic failed. The symbol nnnn representstones that the transmission test unit (TTU) measured.

• Replace card.

Check +48V switch - Indicates that return relay is not operating correctly.

• Reversal Rel. Refer to the Lines Maintenance Guide for the correctprocedure.

CKT CANNOT BE IDLED - Indicates attempt to idle circuit pack for testingfailed. Test did not start.

• Replace card. Refer to the Lines Maintenance Guide for the correctprocedure.

Coin Collect - Indicates that the positive coin control voltage below test ofthe extended diagnostic failed.

• Replace card.

Coin Presence - Indicates that the positive or negative coin control groundbelow test of the extended diagnostic failed.

• Replace card.

130 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 131: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Coin Return - Indicates that negative coin control voltage below test of theextended diagnostic failed.

• Replace card.

Communicationfailed to a line card - Indicates that a line card did notreceive a C-channel response.

• Check card.

Communicationfailed to NT1 - Indicates that NT1 did not receive a C-channel response.

• Check NT1.

Connection Fail - Indicates that test connection between PM and remotemodule failed.

• Check the PM and remote module for errors. Post the PM and remotemodule PM level of the MAP. Issue the command string QUERYPMFLT. Replace any defective cards. If PM and remote module are free oferrors, test DS-1 link A.

CONNECTION FAULT - Indicates that the line and the test equipment didnot connect.

• Attempt again. Refer to the Lines Maintenance Guide for the correctprocedure.

D CHANNEL LINK ACTION FAILED - Indicates that an attempt to seizethe XMS-based peripheral module (XPM) D-channel link failed

• Check the D-channel or XPM links.

DCH cont failed: EC ON: LU interface - Indicates the D-channel handler(DCH) continuity test at the LU interface with echo cancellation ON, failed.

DCH cont failed: EC OFF: LU interface - Indicates the DCH continuity testat the LU interface with echo cancellation ON, failed.

DCH cont failed: L interface - Indicates DCH continuity test at the Linterface failed.

• Check ISLM links.

DCH cont failed: T interface - Indicates test of DCH continuity at the Tinterface failed.

ALT101 131

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 132: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

DCH cont No response from XPM or DCH - Indicates the XPM or the DCHdid not respond to the continuity test.

• Test DCH.

DCH not in service - Indicates the DCH selected for test is not in service.

• Check DCH and links.

Defective DSIC circuit on DPMC - Indicates an error in one of the DSICcircuits on the DPMC. Replace the defective DPMC.

• Replace card.

Defective facility sensors on DPMC - Indicates that an error occurs in theDPMC facility sensors. Replace the defective DPMC.

• Replace card.

Defective mate 10V regulator on DPMC - Indicates that an error occurs inthe mate 10V regulator on the DPMC. Replace the defective DPMC.

• Replace card.

Defective prime 10V regulator on DPMC - Indicates that an error occurs inthe prime 10V regulator on the DPMC. Replace the defective DPMC.

• Replace card.

Defective relay drivers on DPMC. - Indicates that an error occurs in theDPMC relay drivers. Replace the defective DPMC.

• Replace card.

Defective 30V meas. circuit on DPMC - Indicates that an error occurs inthe DPMC 30V-measurement-circuit. Replace the defective DPMC.

• Replace card.

Defective 30V power source on DPMC - Indicates that an error occurs inthe DPMC 30V power source. Replace the defective DPMC.

• Replace card.

DIAGNOSTIC ABORTED - Indicates that the facility establishes aconnection. Extended diagnostic aborts for reasons not known.

• Check facility. Refer to the Lines Maintenance Guide for the correctprocedure.

132 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 133: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Digital Port Card not present - Indicates that the DPC for the line subgroupthat contains the given LEN is not there. Insert an 8X47 card in the correctslot.

• Insert card.

DPMC control logic fault - Indicates that an error occurs in the DPMCcontrol logic. Replace the defective DPMC.

• Replace card.

DPMC failed to operate relay - Indicates that the DPMC failed to operatethe relay to connect the DPMC to the line for analysis. It is possible that theDPMC (8X55) is defective. Replace the 8X55 and repeat the test. If thecondition persists, replace the correct digital port card (8X47).

• Replace card.

DPMC in use by another line on the DLM - Indicates that DPMC mustperform tests on the DPC. The DPMC is not available to perform the tests.The DPMC is already performing tests on another line on the same DLMby manual or system request. Repeat the test. If the condition persists,execute the LOOPBK QUERY ALL command (MAP level LTPDATA). Usethe LOOPBK DPC command to verify that MADOs do not have active DPCloopback. The DPMC remains in use by a MADO if that MADO has a DPCloopback active. The DPMC remains in use until you issue a LOOPBK RLScommand for that MADO.

• Attempt again.

DSIP failure on looparound on/off - Indicates that the digital set interfaceprocessor (DSIP) failed to turn the PCM looparound on/off at the DPC.This failure occurs when you use the DPMC. Check the DLM. Install andverify that the DPMC is in the correct slot. Verify the versions of the DSIPfirmware and the DLM software load.

• Check peripherals.

DSIP failed to connect DPMC - Indicates that the DSIP did not detect theDPMC (8X55) in the DLM. Check the DLM. Verify that the 8X55 is in thecorrect slot. If the 8X55 is in the correct slot, remove and reinstall the cardand repeat the test. If the problem persists, replace the defective DPMC.

• Check peripherals.

ALT101 133

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 134: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

DSIP failed to perform DPMC test - Indicates the need to use the DPMC.The DSIP did not execute the DPMC test that precedes each use of theDPMC. Check the versions of the DSIP firmware and the DLM softwareload.

• Check peripherals.

DSIP failed to perform test - Indicates that the DSIP failed to perform theset occurrence test. Replace 8X49 card.

• Replace card.

nnnn nnnn nnnn nnnn ECHO RET LOSS - Indicates that the echo returnloss (ERL) subtest of the extended diagnostic failed. The extendeddiagnostic fails when nnnn represents tones measured by the transmissiontest unit (TTU).

• Replace card.

nnnn nnnn nnnn nnnn Eq Pads Test - Provides the results of theequalization pads test failure.

• Replace card. Can be a defective line card or an incorrect line card.

Equalization High - Indicates circuit pack obstruction is high with referenceto line and set requirements. Indicates that loop or set obstruction is highwith reference to circuit pack requirements.

• Replace card or check loop and set. Refer to the Lines MaintenanceGuide for the correct procedure.

Equalization Low - Indicates circuit pack obstruction is low with referenceto circuit pack and set requirements. The value also can indicate that loopor set obstruction is low with reference to circuit pack requirements.

• Replace card or check loop and set. Refer to the Lines MaintenanceGuide for the correct procedure.

EQUIP FAULT - Indicates that a hardware error that is not known causedtest to fail.

• Attempt again. Refer to the Lines Maintenance Guide for the correctprocedure.

Excessive voltage (>10V) on loop - Indicates that the loop measuresvoltage in excess of 10V. Check the MDF and jack panel and verify that noexternal voltages apply to the line.

• Check facility.

134 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 135: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Ext Not Datafilled - Indicates that a circuit pack connects to a key set. Thesystem tests the circuit pack. An extension is not entered correctly incustomer data Table KSETINV.

• Refer to the data schema section of the Translations Guide to correctKSETINV.

Ext Not Responding - Indicates that the system tests a circuit pack thatconnects to a key set. One of the extensions entered in customer dataTable KSETINV did not respond to the test.

• Refer to the data schema section of the Translations Guide to correctKSETINV.

EXTERNAL DCH CONTINUITY TEST FAILED - Indicates that the DCHcontinuity test failed.

• Check the D-channel.

External RAM fault detected - Indicates that the line card external RAMdetects an error.

• Replace card. Refer to the Lines Maintenance Guide for the correctprocedure.

Failed data transmission to set - Indicates that an error occurred in thereceived data. The value can indicate that no data was received becauseof a bad loop or a damaged subscriber access multiplexer (SAM). No datacan be received if the SAM was unplugged or powered down

• Check loop and set. Refer to the data schema section of theTranslations Guide to correct KSETINV.

FAILED TO OPERATE CUTOFF RELAY - Indicates that the cutoff relayfailed to operate

• Check relay.

FAILED TO RELEASE LOOPBK. - Indicates a loopback release failure incontinuity test to the L, U, and T interfaces

FAILED TO RUN DCHCON. TRY AGAIN. - Indicates that the DCHcontinuity test did not run

• Check DCH and XPM and attempt test again.

Failed to set 2B+D loopbk: L interf. - Indicates the B-channels and D-channel loopback at the L-interface failed.

• Loopback L.

ALT101 135

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 136: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Failed to set 2B+D loopbk: LU interf. - Indicates the two B-channels and D-channel loopback at the LU interface failed.

• Loopback LU.

Failed to set 2B+D loopback: T interf. - Indicates the two B channels andD-channel loopback at the T interface failed.

• Loopback T.

Fault in DPC, subscriber loop, or set - Indicates the pulse code modulation(PCM) looparound test at the DSIC in set failed. The PCM looparound testat the PSTS passed. Because the DLM is not equipped with a DPMC(8X55), the DPC cannot perform the test. Check jack and line cord. Setand verify all connections. If the connections are in order, connect a testset to the line. If the line continues to fail diagnostics, the DLIC orassociated circuitry on the DPC is defective. Replace the DPC. If the linepasses diagnostics with the test set, the set of the subscriber is defective.Replace the defective set.

• Check facility.

Fault in set -- set not responding - Indicates that the set did notacknowledge the occurrence and failed signaling tests. The DPMC facilitysensors detect a set on the line. Check the set and verify all connections. Ifthe connections are in order, the set is defective. Replace the defectiveset.

• Check facility.

Foreign voltage on loop -- check MDF - Indicates that the DPMCdiagnosed the subscriber loop and detected a foreign voltage. Check thesubscriber loop.

• Check facility.

nnnn nnnn nnnn nnnn Flux Cancel Test - Provides the results of the fluxcancellation test

• Replace card.

FUNCTIONAL TEST FAIL - Indicates system detected a hardware faultduring function test procedure of suspect equipment

• Replace card. Refer to the Lines Maintenance Guide for the correctprocedure.

136 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 137: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

IAC Queue full - Indicates that the integrated- services digital- network(ISDN) access controller queue is full

• Attempt test again.

INCOMING SEIZURE - Indicates the facility was seized before a requestfor a test occurred. The facility was not tested.

• Check facility. Refer to the Lines Maintenance Guide for the correctprocedure.

Internal RAM/CPU fault detected - Indicates that either the line cardinternal random access memory(RAM) or the central processing unit(CPU)detects error.

• Replace card. Refer to the Lines Maintenance Guide for the correctprocedure.

INVALID MAINTENANCE COMMAND TO XPM - Indicates that the XMS-based peripheral module (XPM) does not recognize the command.

• Check XPM load.

INVALID ISLC COMMAND - Indicates that the XPM does not recognizethe maintenance command sent to the XPM.

• Check the XPM load.

INVALID MAINTENANCE REQUEST TO XPM - Indicates that the XPMdoes not recognize the request from the DIAG command.

• Check the parameters.

ISLC REPLY RELAY STATE IS OUT OF RANGE - Indicates that the XPMdoes not recognize the relay tape.

• Check the XPM load. Check the line entry in the central control(CC)and the XPM.

ISLC STANDARD REPLY BYTE INVALID XPM - Indicates that the CCdoes not recognize the reply from the load.

• Check the XPM. Check the line entry in the CC and the XPM.

Invalid channel number to DPMC - Indicates that the DSIP received acommand for which the specified channel was not correctly looped/unlooped. Verify the versions of the DLM and LTC/LGC software and theDSIP firmware.

• Check peripherals.

ALT101 137

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 138: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Invalid DCH - Indicates that the test selected a DCH that is not valid.

Invalid DPMC request sent to DLM - Indicates that the DLM received aDPMC command that was not valid. Verify the versions of the DLM andline trunk controller/line group controller(LTC/LGC) software loads.

• Check peripherals.

Invalid request to ISDN access controller (IAC). - Indicates that an IACreceived a request that was not valid.

• Check IAC load.

Invalid response from IAC/DCH - Indicates that the response from theISDN access controller or the DCH was not valid.

• Check DCH.

Invalid response to self test - Indicates that the line card sent a responsethat was not valid during a self test. Normally, a response that is not validoccurs when a damaged line card is present. A response that is not validcan occur when the card in the slot is not an entered card.

• Replace card. Refer to the Lines Maintenance Guide for the correctprocedure.

Invalid RIT reply from DSIP (XXXX) - The XXXX indicates the point whenthe signaling looparound test performed(PSTS, DPC, DSIC, or MADO).The XXXX indicates that the DSIP reply to the RIT signaling looparound,message is not valid. Replace the 8X49 card. If condition continues,replace the 8X46 card.

• Replace card.

ISLM not responding - Indicates that the ISDN line module does notrespond.

• Check ISLM.

Jack Access Active - Indicates that a jack access sets up at the remotecarrier urban (RCU).

• Retry the test.

LC BPVO test failed. - Register indicates line card bipolar voltage overflow(BPVO) register test failed.

• Check line card.

138 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 139: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

LC context restore failed. - Indicates line card status after a context restorefailed.

• Check line card.

LU interface not activated. - Indicates that the LU interface is not activated.

• Check line card.

Line Data Error:Terminal id. - Indicates an error in data on the line.

• Check data.

Local Testing Active - Indicates that a local test initiated at themaintenance card of the RCU.

• Retry the test.

Loop communication fault - Indicates that a loop component does not sendC-channel responses.

Looped data does not match - The XXXX indicates the point where thesignaling looparound test performs(PSTS, DPC, DSIC, or MADO). TheXXXX indicates that the data received from the looparound test does notmatch the data sent. Replace the 8X46 card. If the condition continues,replace the 8X49 card.

• Replace card.

Looped message not received from DPC - Indicates that the signalinglooparound test at the DPC failed. Replace the DPC (8X47).

• Replace card.

Looped message not received from DSIC - Indicates that the signalinglooparound test at the DSIC failed. Check the set and verify allconnections. If the connections are in order, replace the set.

• Check facility.

Looped message not received from MADO - Indicates that the signalinglooparound test at the MADO failed. Check the MADO and verify allconnections. If the connections are in order, replace the MADO.

• Check facility.

Looped message not received from PSTS - Indicates that the signalinglooparound test at the PSTS failed. Replace the 8X46 card. Replace the8X49 card only if the condition continues.

• Replace card.

ALT101 139

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 140: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

LTA CANCELLED - Indicates a cancelled request line test access (LTA).The test aborted.

• Attempt again. Refer to the Lines Maintenance Guide for the correctprocedure.

MADO reset error - Indicates that the MADO failed to perform MADO resetfunction. Check the MADO and verify all connections. If the connectionsare in order, the MADO is defective. Replace the defective MADO.

• Check facility.

MADO self test failed - Indicates that the MADO acknowledged itspresence and passed signaling and PCM tests. The microprocessor in theMADO failed the self-test. Check the MADO and verify all connections. Ifthe connections are in order, the MADO is defective. Replace the defectiveMADO.

• Check facility.

Main Datafilled - Indicates the system tested a circuit pack that connects toa key set. The main set is not entered correctly in customer data TableKSETINV.

• Check loop and set. Refer to the data schema section of theTranslations Guide to correct KSETINV.

Main Not Responding - Indicates the system tested a circuit pack thatconnects to a business set. The main set entered in customer data TableKSETINV does not respond to the test.

• Check loop and set. Refer to the Lines Maintenance Guide for thecorrect procedure.

Messaging Failure To Data Option - Indicates MADO firmware does notrecognize messaging. It is possible that the microprocessor in the MADOlost sanity. Communication between the DISC and the MADO failed.

• Check 8X49 set. Make sure you plugged the MADO power in, and thepower source works. If the power source works, run the diagnostic onanother MADO that is on the same port card and DLM unit. If thediagnostic passes, the MADO microcontroller is defective. Replace thedefective microcontroller. Check the DSIP 8X49 card for a problem.

140 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 141: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Messaging Failure To Set Firmware - Indicates the M3000 digitaltelephone firmware does not recognize messaging. It is possible that themicroprocessor in the set lost sanity. Communication between the DISCand the firmware chip failed.

• Check 8X49 set. Make sure you plugged the M3000 power source inand that the power source works. If the power source works, run thediagnostic on another set that is on the same port card and DLM unit. Ifthe diagnostic passes, the microcontroller of the set is defective.Replace the defective microcontroller. Check the DSIP 8X49 card for aproblem.

Messaging Inhibited - Indicates messaging inhibited between the PM andremote module for a limited time

• Attempt test again.

Metering Card not Datafilled - Indicates metering pulse test detects adifference in the line data. Entries in Table LENLINES indicate the 6X94AAline under test supports an SPM or a coin phone. Entries in Table LNINVindicate that a 6X95AA metering tone card is not present in slot 0. Slot 0 isof the odd line subgroup for the line concentrating module (LCM) drawerthat contains the line under test.

• Check data. Refer to the data schema section of the TranslationsGuide to correct KSETINV.

Metering Card not Responding - Indicates metering tone card (6X95AA)did not respond, either because the card is defective or is not present inthe drawer

• Check card or replace card. This action depends on when the systemdetected the failure. Refer to the Lines Maintenance Guide for thecorrect procedure.

Metering Card set to 16KHz - Indicates metering pulse test for a 6X94AAline card detected a metering pulse with a frequency of 16KHz. A dipswitch supplied at either 12KHz or 16 KHz sets the 6X95AA metering tonecard. The dip switch is set to 16 KHz.

• Change dip switch setting. Refer to the Lines Maintenance Guide forthe correct procedure.

Modem fault detected - Indicates the line card modem circuitry contains anerror.

• Replace card. Refer to the Lines Maintenance Guide for the correctprocedure.

ALT101 141

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 142: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Metallic test access (MTA) connection failure - Indicates MTA busy.

• Check driver.

Mtc Bus Unavailable - Indicates that maintenance bus at the remote carrierurban (RCU) is not available for test.

• Test again. If maintenance bus is not available after multiple attempts,check the faceplate of the maintenance card for alarms. Check theperipheral module (PM) level of the MAP for RCU alarms. Post theRCU and issue the command QUERYPM FLT. A defectivemaintenance card is the possible cause of the problem.

Neg Coin Off-Hook - Indicates that the negative coin control voltagesubtest of the extended diagnostic failed.

• Replace card.

No card present in slot. - Indicates that a card is not present in the slot.

• Insert card.

NO CARD RESPONSE - Indicates that an attempt to idle circuit pack fortesting failed. Test did not start.

• Replace card. Refer to the Lines Maintenance Guide for the correctprocedure.

NO COMMUNICATION - Indicates that an attempt to idle circuit pack fortesting fails. Test does not start

• Replace card. Refer to the Lines Maintenance Guide for the correctprocedure.

No digit message - Indicates diagnostics error. The system can generatethis message if the ALT attempts to test the line while the user attempts tooriginate a call. This message can indicate that the line card is defective.

• Repeat the test to determine what the condition is. If the "No digitmessage" persists after two tests, the line card should be replaced.

No DSIP RIT reply received (XXXX) - The XXXX indicates the point atwhich the signaling looparound test performs (PSTS, DPC, DSIC, orMADO). Indicates the DSIP did not reply to the RIT (signaling looparound)message from the DLM. Replace 8X49 card.

• Replace card.

No Line Card - Indicates the line card that requires testing is not present.

• Insert card.

142 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 143: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

NO LINE CARD DIAG - Indicates facility test completed correctly. Facilitytest aborted before circuit pack test was complete.

NO LOOP CONNECTION - Indicates an error detected during an attemptto connect through the network.

• Check network.

No LTA Card - Indicates the line test access (LTA) card on the RCU is notpresent.

• Insert LTA card.

No MADO or fault in DPC, loop, or set - Indicates MADO did notacknowledge the occurrence. Check the set and MADO and verify allconnections. If all connections are in order, the error is either in the loop orin the DLIC or associated circuitry on the DPC. Check loop accuracy. If theerror is not in the loop, replace the DPC.

• Check facility.

No MADO or signaling failure in MADO - Indicates the MADO did notacknowledge the occurrence and fails signaling tests. The voice setacknowledges the occurrence of the MADO and passed the signalingtests. Either there is no MADO present or the MADO is defective. Checkthe set to verify the correct installation of MADO and the correct connectionof the cables. If connections are in order, replace the MADO.

• Check facility.

No Mtc Card - Indicates that the maintenance card at the RCU is notavailable.

• Insert maintenance card.

NO T INTERFACE SYNC - Indicates that the synchronization at the T-loopdid not occur.

• Check that the terminals are plugged in.

No response from XPM - Indicates the XPM does not respond.

• Check peripherals.

ALT101 143

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 144: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

NO RESPONSE FROM LTC - Indicates an attempt to idle line trunkcontroller for test fails. Test does not start.

• Check peripherals.or No Response from LTC - Indicates that thediagnostic process sent a message and the LTC/LGC did not respond.Check the LTC/LGC and the DLM.

• Check peripherals.

NO RESPONSE FROM PERIPHERAL - Indicates an attempt to idleperipheral for test failed and test did not start.

• Check peripherals.

No response to self test - Indicates card did not respond to a request for aself test. Normally the card does not respond when the line card isdefective or the card in the slot is not the entered card

• Replace card. Refer to the Lines Maintenance Guide for the correctprocedure.

No set or fault in DPC, loop, or set - Indicates that the set did notacknowledge the occurrence and failed signaling tests. You cannot testDPC signaling. The DLM that contains the corresponding DPC does nothave a DPMC (8X55). Verify that a set is present and check the jack, linecord, and set connections. If the connections are in order, replace the setwith a test set. If the line continues to fail diagnostics, the DPC is defective.Replace the defective DPC. Relocate the DN to a different LEN. Enter thedefective LEN into Table IVDTRBL to block the bad port until you canreplace the card. If the line passes diagnostics with the test set, the set ofthe subscriber is defective. Replace the defective set.

• Check facility.

No Signaling, Loop at Set - Indicates signal was not at set sent fromperipheral module to connected keyset.

• Replace card. Refer to the Lines Maintenance Guide for the correctprocedure.

No Signaling to Set - Indicates that peripheral module did not send a signalor that the connected keyset did not receive a signal.

• Check Card and Set. Refer to the Lines Maintenance Guide for thecorrect procedure.

No signaling to card rr/ss - Indicates a loop signaling error at the cardoccurred. The letters ''rr'' indicate the number of messages received; ''ss''indicates the number of messages sent.

144 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 145: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

No SMS Pside Channel - Indicates that a free DS-1 channel is not present.

• Attempt the test again.

No SMU Pside Channel - Indicates that a free DS-1 channel is not present.

• Attempt the test again.

NO TONE Detected - Indicates public- safety- answering point (PSAP) testfails at the ALT level of the MAP. The test fails because TTU does notdetect the tone in the allowed time interval.

• Check TTU/PSAP.

No Wink From PSAP - Indicates PSAP test fails at the ALT level of theMAP because no wink is received from the PSAP

• Check PSAP. Make PSAP hardware and entries of the card code of thetested line compatible. Make sure you entered ''E911_PSAP_RECPRE_WINK_TIME'' parameter in Table OFCENG is entered correctly.

PCM looparound failure at DSIC in set or, PCM failure at DSIC in set -Indicates that the set acknowledged the occurrence and passed thesignaling looparound test at the set. The set passed the PCM looparoundtest at the PSTS. The set failed the PCM looparound test at the set. First,substitute a known good set. If the error disappears, the original set wasbad. If the error continues, check loop accuracy. If the loop proves good,the DPC is defective. Replace the defective DPC.

• Check facility.

Noise Level nnnn DB WEIGHT NOISE - Indicates that the noise subtest ofthe extended diagnostic failed. Nnnn represents the noise level that thetransmission test unit (TTU) measured.

• Replace card.

Noise Level nnnn DB NOTCH NOISE - Indicates that the noise subtest ofthe extended diagnostic failed. Nnnn represents the noise level that thetransmission test unit (TTU) measured.

• Replace card.

NT1 BPVO register test failed - Indicates network termination 1 (NT1)bipolar voltage overflow register test failed.

• Check NT1.

ALT101 145

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 146: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

NT1 context restore failed - Indicates NT1 state after a context restorefailed.

• Check NT1.

NT1 REPLY OPERATION TIME INVALID - Indicates the reply time periodwas not valid

• Check the NT1. Perform full diagnostics.

Off-Hook - Indicates that the off-hook subtest of the extended diagnosticfailed

• Replace card.

On-Hook - Indicates that the on-hook subtest of the extended diagnosticfailed

• Replace card.

Open Circuit check loop (or no set) - Indicates that the DPMC diagnosedthe subscriber loop and detected an open circuit wad. Verify that a setconnects on the loop. Check the subscriber loop. If no errors are present,the open circuit is internal to the set.

• Check facility.

nnnn nnnn nnnn nnnn Pad nDB Test - Provides the result of the Pad DBtest. The letter n represents the exact pad value on which the test fails

• Replace card.

PAM Loopback - Indicates the pulse amplitude modulation (PAM) loopbacktest failed. This test consists of a test tone sent from the RCU maintenancecard to the transmit/receive multiplexer card. The test tone loops andreturns to the maintenance card for analysis.

• Replace transmit/receive multiplexer card (NT3A18).

PCM looparound not activated (XXXXX) - The XXXXX indicates the pointat which the PCM looparound test performs (PSTS, DPC, DSIC, MADO, orCODEC.) Indicates that the PCM looparound can not activate.

146 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 147: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Timeout on PSAP seize - Indicates PSAP test invoked by the ALT systemfails. The line initiates a PSAP test. The PSAP test fails when a responsefrom the line does not occur.

• Check PSAP/DS-1 or channel bank hardware. Try other lines to thesame PSAP destination. If the lines pass, it is only an isolated circuitproblem. If the lines fail, it is a PSAP problem, a DS-1 carrier problem,or a channel bank hardware problem. To rectify the problem, replace8X49 card.

PCM looparound failure at DSIC in set or PCM failure at DSIC in set -Indicates the set acknowledged its presence and passed the signalinglooparound test at the set. The set passed the PCM looparound test at thePSTS. The set failed the PCM looparound test at the set. First, substitute aknown good set. If the error disappears, the original set is defective. If theerror continues, check loop accuracy. If the loop proves good, the DPC isdefective. Replace the defective DPC.

• Check facility.

PCM looparound not released (XXXXX) - The XXXXX indicates the point atwhich the PCM looparound test performed (PSTS, DPC, DSIC, MADO, orCODEC). Indicates the PCM looparound does not deactivate.

• Replace 8X49 card.

PCM looparound test failed at DPC - Indicates the PCM looparound testthat uses the tone generation and tone detection circuitry of the TTT failed.The PCM looparound test failed at the DPC looparound point. Thereadings that the tone detection circuitry takes, indicate that the frequencyof the level is not acceptable.

• Replace DPC (8X47).

PCM looparound test failed at PSTS - Indicates that the PCM looparoundtest that uses the tone generation and tone detection circuitry of TTT failed.The PCM looparound test failed at the PSTS looparound point. Thereadings that the tone detection circuitry takes, indicate that the frequencyand the level or both are not acceptable.

• Replace 8X46 card. Replace 8X49 card ONLY if the problem persists.

PCM looparound test failed at XXXXX - The XXXXX indicates the point atwhich the PCM looparound test performed (DSIC, MADO, or CODEC).Indicates the PCM looparound test that uses the tone generation and tone

ALT101 147

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 148: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

detection circuitry of the TTT failed. The PCM looparound test failed at theDPC looparound point. The readings that the tone detection circuitry takes,indicate that the frequency and the level or both are not acceptable.

• Check facility. Check the set and verify all connections. If allconnections are in order, the set (or MADO) is defective. For XXXXX =DSIC or CODEC, replace the set. For XXXXX = MADO, replace theMADO first. Replace the set ONLY if the problem persists.

PM Not Ready - Indicates the remote module is not ready to process testrequests.

• Attempt the test again.

PM Reply Timeout - Indicates the PM failed to respond to a CC request totest the remote module. Indicates failed-to-return test results in an exacttime. Indicates the remote module failed to respond to a PM test request orfailed to return test results in an exact time. Defective software can cause aPM reply timeout. Collect PM180 and SWER reports and contactmaintenance personnel.

• Attempt the test again. If the error persists, check for alarms and logsthat indicate defective common equipment. Cards involved in themessage path between the CC, PM, and remote module can bedefective.

Positive Coin Off-Hook - Indicates that the positive coin control voltagesubtest of the extended diagnostic failed.

• Replace card.

Pre V. Trip - Indicates ringing current not normally tripped.

• Ringing generator (RG) Trip Fail. Refer to the Lines MaintenanceGuide for the correct procedure.

PSTS test resources not available - Indicates that another line alreadyuses the PSTS test resources on the same DLM unit. Repeat the test. Ifthe condition continues, execute the command LOOPBK QUERY ALL atthe LTPDATA level of the MAP. Verify that no MADO on this DLM unit hasa PSTS loopback that activates manually.

• Attempt again.

RESET FAILED - Indicates attempt to reset circuit pack after test failed.Pack did not return to service.

• Replace card. Refer to the Lines Maintenance Guide for the correctprocedure.

148 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 149: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Resistance XXXXXX OHMS - Indicates failure of sealing current test. TheXXXXXX represents a decimal number.

• Battery feed.

Ringing Failed

• Check ringing.

Ringing Failed Pre Trip

• Check ringing.

RIT failed to run - Indicates the LGC did not perform a run integrity test(RIT)

• Check PM.

ROM fault detected - Indicates fault detected on the line card read-onlymemory (ROM).

• Replace card. Phone subscriber and inquire if the display section of thesuspect set functions correctly. If the display section does not functioncorrectly, arrange to replace or service the set. Refer to the LinesMaintenance Guide for the correct procedure.

Reverse Battery - Indicates the reverse battery subtest of the extendeddiagnostic failed.

• Replace the card.

ROM f RAM p SCP p p - Indicates the shower queue timer diagnosed anISDN loop and the diagnostic failed this self test. The reason for failureincludes all diagnostic errors for T line card.

• Diagnose the ISDN loop from the MAP terminal in order to perform anextended diagnostic.

Set Display Not Responding - Indicates the keyset display micro did notreport its state during the diagnostic test.

Short circuit check subs loop & set - Indicates that the DPMC diagnosedthe subscriber loop and detected a short circuit. Check the subscriber loop.If you do not detect errors, the short can be internal to the set.

• Check facility.

ALT101 149

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 150: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

SHORT TEST ONLY - Indicates a request for an extended diagnostic test.An extended diagnostic test did not perform and a short test performedinstead.

• Attempt again. Refer to the Lines Maintenance Guide for the correctprocedure.

Signal failure - DPC, loop, or set - Indicates that voice set acknowledgedthe occurrence but failed signaling tests. The DLM that contains thecorresponding digital port card does not have a digital port maintenancecard (DPMC) 8X55). The DLM cannot test the DPC signaling. Check thejack, line cord, and set. Verify all connections. If the connections are inorder, replace the set with a test set that passes diagnostics. If the linecontinues to fail diagnostics, the DPC is defective. Replace the defectiveDPC. The DN can be relocated to a different LEN. Enter the LEN intoTable IVDTRBL. The defective LEN marks the bad port until you replacethe card. If the line passes diagnostics with the test set, the set of thesubscriber is defective. Replace the defective set.

• Check facility.

Signal failure DPC or Meridian set - Indicates the set acknowledged theoccurrence. The signaling looparound test at the set failed. First substitutea known good set. If the error disappears, the original set is defective. Ifthe error continues, check loop accuracy. If the loop proves good, the DPCis defective. Replace the defective DPC.

• Check facility.

Signal failure MADO not responding - Indicates that only the voice setacknowledged the occurrence. Both the set and the MADO failed signalingtests. The DLM that contains the associated digital port card does not havea digital port maintenance card (DPMC) 8X55. The DLM cannot test theDPC signaling. Check the set, MADO, and line cord. Verify all connections.If the connections are in order, replace the set with a test set. If the linecontinues to fail diagnostics, the DPC is defective. Replace the defectiveDPC. You can move the voice and data DNs to different LENs. Enter thedefective LENs into Table IVDTRBL. The defective LENs block bad portsuntil you replace the card. If the line passes diagnostics with the test set,the subscriber set is defective. Replace the defective set.

• Check facility.

Signaling failure in MADO - Indicates that the MADO acknowledged theoccurrence but failed signaling tests. The voice set acknowledged theoccurrence and passed signaling tests. Either the MADO is defective or

150 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 151: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

connections are defective. Check the set to verify the correct installation ofMADO and the correct connection of the cables. If connections are inorder, replace the MADO.

• Check facility.

Single-End - Indicates short diagnostics for local tests failed.

• Replace card.

Suspected LCC Fault - Indicates that the system suspects that the linecard under test resides on a defective line card carrier (LCC).

• Test other line cards on the LCC. If all other line cards fail, replace theLCC. If other line cards pass diagnostics, replace the original line cardthat failed.

SV1 Stuck After Ringing - Indicates supervision bit 1 (SV1) that transmitson/off-hook state was high after system applied ringing. When the systemreleases the ringing relay, the (SV1) must be low.

• Replace card.

Software error -- check for SWERR - Indicates a software error (SWERR)occurred.

• Check logs and retain the SWERR for use by technical supportpersonnel.

SV1 Stuck Before Ringing - Indicates SV1 that transmits on/off-hook statewas low before system applied ringing. When the system operates theringing relay, SV1 must be high.

• Replace card.

Sync loss at U interface - Indicates the U interface lost synchronization.

• Check NT1 Intst.

Talk Battery - Indicates that the talk battery subtest of the extendeddiagnostic failed.

• Replace card.

Termination out of range. - Indicates a termination check discoveredtermination to be out of range.

• Test.

ALT101 151

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 152: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Test Alarm Return Code - Indicates that an error is present at the remotemodule. The fault prevents the execution of the test request for the remotemodule.

• Check the remote module. Defective common equipment cards,defective wiring, or a defective channel test unit can cause this failure.

TEST EQUIPMENT FAULT - Indicates system detected error on testequipment required to complete test procedures that remain.

• Attempt again. Refer to the Lines Maintenance Guide for the correctprocedure.

Test register failed at LC - Indicates test register at ISDN line card failure.

• Check line card.

Test register failed at NT1 - Indicates test register at NT1 failed.

• Check NT1.

Timeout on PSAP seize - Indicates PSAP test that the alternate systeminvolved failed. The line initiates a PSAP test. The PSAP test fails whenthe line under test does not respond to the system.

• Check PSAP/DS1 or channel bank hardware. Try other lines to thesame PSAP destination. If these lines pass, the problem is in thecircuit. If the lines fail, the problem is in the PSAP, DS-1 carrier, or inchannel bank hardware.

nnnn nnnn nnnn nnnn THL Test - Provides the results of the transhybridloss test

• Replace card.

Tip XXX v. Ring XXX v. CO operated. - Indicates relay failed to operate

• Check cutoff relay.

Tip XXX v. Ring XXX v. CO released. - Indicates that the system detectedvoltage out of range before the cutoff relay that performed. The XXXrepresents a decimal number.

• Check power supply.

Tip Ringing, ANI Gnd - Indicates the tip ringing subtest or ANI groundsubtest of the extended diagnostic failed

• Replace card.

152 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 153: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Unexpected PM Reply - Indicates that the PM or remote module sent amessage during testing that the DMS switch did not interpret

• Attempt the test again. If the error continues, collect log and SWERRreports and contact maintenance personnel.

WRONG CARD INSERTED - Indicates circuit pack inserted is not typeexpected

• Change card. Refer to the Lines Maintenance Guide for the correctprocedure.

Wrong Tone - Indicates PSAP test failed at the ALT level of the MAP. ThePSAP test fails when the PSAP test sends ANI digits and does not returnbusy tone.

• Attempt again. Test other lines to the same PSAP destination. If theselines pass, the error represents only an isolated circuit problem. If thelines fail, the error represents either a PSAP problem or a DS-1 carrierproblem.

11600 Hz 4.8 Volts 178 mSecs - Indicates metering pulse test for a6X94AA line card detected a metering pulse. One or more of frequency,amplitude, and duration of the metering pulse were not in acceptablelevels.

• Metering. Refer to the Lines Maintenance Guide for the correctprocedure.

30V DPC power source defective - Indicates that the DPMC tested theDPC. The DPMC detected a defective 30-volt DPC power source. Replacethe defective DPC.

• Replace card.

U Loop parameters out of range. - Indicates a U Loop test detected U Loopparameters that were not in range.

• Test.

Remedial action

• If DIAGNOSTIC REASON and ACTION REQUIRED appear in theExplanation Table and cycltxt = RETEST 2, use the followingreferences to isolate and correct failures indicated by ALT101:

• Refer to the data schema section of the Translations Guide for allfailures associated with entry.

ALT101 153

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 154: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• Refer to Trouble Locating and Clearing Procedures for all failuresassociated with CC or PM.

• Refer to the Lines Maintenance Guide for more information on linetesting.

AttributesAttribute Value

Severity Indeterminate

FormatALT101 mmmdd hh:mm:ss ssdd FAIL ALT

len DN dn cycltxt

TEST TYPE typtxt DIAGNOSTIC RESULT diagtxt

ACTION REQUIRED acttxt CARD TYPE pec

Selected field descriptionsField Value Fixed or

VariableDescription

FAIL ALT Constant Fixed Indicates FAIL ALT was performed

len Alphanumeric textstring

Variable The line equipment number (LEN) forsuspect line equipment. See Table I.

DN Constant Fixed Indicates that a directory number (DN)follows. See Table I.

dn Integers Variable The directory number (DN) for thesuspect line equipment. See Table I.

cycltxt 1st CYCLE Variable Indicates the line equipment failed thespecified test the first time the test ran

RETEST 1 Variable Indicates the line equipment failed thespecified test during the first automaticretest of the line equipment

RETEST 2 Variable Indicates the line equipment failed thespecified test during the secondautomatic retest of the line equipment

typtxt DIAG Variable Indicates extended diagnostic testwas performed on suspect lineequipment

BAL NET Variable Indicates an on-hook balance networktest was performed

154 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 155: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

LIT Variable Indicates the line insulation test wasperformed

SDIAG Variable Indicates a short diagnostic test wasperformed

CKTTST Variable Indicates circuit test was performed onsuspected line equipment

DIAGNOSTICRESULT

Symbolic text Variable Indicates the result of the diagnostictest. Refer to the Diagnostic results inAdditional information.

CARD TYPE Symbolic text Variable Indicates the card number. See TableI.

Active message exampleALT101 APR01 12:00:00 2112 FAIL ALT

HOST 00 0 00 27 DN 8057811999 1st CYCLE

TEST TYPE DIAGN DIAGNOSTIC RESULT FUNCTIONAL TEST FAIL

ACTION REQUIRED REPLACE CARD CARD TYPE 3X65AA

ALT101 APR01 12:00:00 2112 FAIL ALT

PSAP 00 0 00 27 DN 8057811999 1st CYCLE

TEST TYPE DIAGN DIAGNOSTIC RESULT Invalid Card Code For Test

ACTION REQUIRED Try Again CARD TYPE PSAPNN

ALT101 OCT31 12:00:01 2112 FAIL ALT

RCU 00 0 00 01 DN 8057811999 1st CYCLE

TEST TYPE DIAGN DIAGNOSTIC RESULT FUNCTIONAL TEST FAIL

ACTION REQUIRED REPLACE CARD CARD TYPE 7A25AA

ALT101 OCT31 12:00:01 2112 FAIL ALT

RCU 00 0 00 01 DN 8057811999 1st CYCLE

TEST TYPE DIAGN DIAGNOSTIC RESULT FUNCTIONAL TEST FAIL

ACTION REQUIRED REPLACE CARD CARD TYPE 7A33AA

ALT101 155

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 156: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

ALT101 OCT31 12:00:01 2112 FAIL ALT

RCU 00 0 00 01 DN 8057811999 1st CYCLE

TEST TYPE DIAGN DIAGNOSTIC RESULT FUNCTIONAL TEST FAIL

ACTION REQUIRED REPLACE CARD CARD TYPE 7A31AA

Clear message examplen/a

Associated OM registers

ALT103The Automatic Line Testing (ALT) subsystem log report. The subsystemgenerates ALT103 when a line insulation test (LIT) performed on lineequipment fails. ALT measures the current voltage. ALT compares thecurrent voltage to the maximum voltage permitted on a line. If the currentvoltage exceeds the maximum permitted, a foreign electromotive force(FEMF) is on the line. ALT performs as a result of either a manual requestfrom the ALT MAP level or based on the ALT schedule. Refer to the ALTMAP level for schedule.

ALT can perform on separate lines. Normally ALT performs on knowngroups of lines. The DMS automatically retests each line that fails the firstrun of ALT. The DMS automatically tests each line that fails during thesecond run of ALT. The DMS can perform any group of line insulation tests(LITs). The system generates ALT103 when the line identified in the reportby its LEN and DN fails. Refer to Line Maintenance Reference Manual,297-1001-594 for more information on ALT.

Remedial actionPerform line diagnostics on the suspect line equipment from the LTP MAPlevel to isolate the error. Refer to Line Maintenance Reference Manual,297-1001-594 for diagnostic tests that can be run on line equipment. Thesystem generates LINE100 or LINE101.

• The system can continue to generate LINE100 (PASS) and ALT103 forthe suspect line equipment during the two retests of ALT failures. If thisaction occurs, contact the next level of maintenance.

• If the system generates LINE101 (FAIL), follow the action required forLINE101.

156 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 157: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Continue attempts to clear the error until one of the following occurs:

• The system generates LINE100 and does not generate ALT 103.

• You contact the next level of maintenance.

AttributesAttribute Value

Severity Indeterminate

FormatALT103 mmmdd hh:mm:ss ssdd FAIL ALT

len DN dn cycltxt

LIT TEST = lttxt RESULT: restxt

MAX nnn VOLTS ACT nnn VOLTS

Selected field descriptionsField Value Fixed or

VariableDescription

FAIL ALT Variable Indicates a fail ALT performed.

len Alphanumeric textstring

Variable The line equipment number (LEN) forsuspect line equipment

DN Constant Fixed Indicates that a directory number (DN)follows

dn Integers Variable The directory number (DN) for thesuspect line equipment

cycltxt 1st CYCLE Variable Indicates line equipment failed thespecified test the first time the testran.

RETEST 1 Variable Indicates line equipment failed thespecified test during the automaticretest of ALT 1st CYCLE failures.

RETEST 2 Variable Indicates line equipment failed thespecified test during the automaticretest of ALT RETEST 1 failures.

LIT TEST ALL TEST Variable Indicates that the suspect lineequipment performed all of the teststhat followed.

CAPACITANCE Variable Measures capacitance valuesbetween tip lead and ground, ring leadand ground, and tip and ring leads.

ALT103 157

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 158: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

FEMF Variable Measures AC/DC FEMF between tiplead and ground, and ring lead andground.

R-G Variable Measures insulation resistancebetween ring lead and ground.

R-T Variable Measures insulation resistancebetween ring and tip leads.

T-G Variable Measures insulation resistancebetween tip lead and ground.

RESULT RING AC FEMF Variable Indicates DC voltage measuredbetween ring lead and ground wasgreater than the maximum levelsallowed.

RING DC FEMF Variable Indicates DC voltage measuredbetween ring lead and ground wasgreater than the maximum levelallowed.

TIP AC FEMF Variable Indicates AC voltage measuredbetween tip lead and ground wasgreater than the maximum levelallowed.

TIP DC FEMF Variable Indicates DC voltage measuredbetween tip lead and ground wasgreater than the maximum levelallowed.

MAX nnn VOLTS 0 to 140 Variable Defines maximum AC/DC voltageallowed on a line. The default is 2.When the system defines the ALTtest, you can use the DEFINEcommand in the ALT MAP to changethe default.

ACT nnn VOLTS -150 to 150 Variable Provides current voltage measured onsuspect line equipment

Active message exampleALT103 APR01 12:00:00 2112 FAIL ALT

HOST 01 1 01 01 DN 8057811999 1st CYCLE

LIT TEST = ALL TEST RESULT: TIP DC FEMF

MAX 2 VOLTS ACT 28 VOLTS

158 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 159: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

ALT104The Automatic Line Testing (ALT) subsystem log report ALT104. THesubsystem generates ALT104 when a line insulation test (LIT) performedon line equipment fails. ALT measures the current insulation resistance inOhms. ALT compares current resistance to the minimum insulationresistance that the line requires. If the current insulation resistance is lowerthan the minimum required, a leak occurs in the insulation of either the tipor ring lead. ALT performs as a result of either a manual request from theALT MAP level or based on the ALT schedule. Refer to ALT MAP level forschedule.

ALT can perform on separate lines. ALT normally performs on knowngroups of lines. The DMS switch automatically tests each line that fails thefirst run of ALT again. The DMS switch automatically tests each line thatfails during the second run of ALT again. The system generates ALT104when the line identified in the report by its LEN and DN fails. Refer to LineMaintenance Guide, 297-1001-594 for more information on ALT.

Remedial actionPerform line diagnostics on the suspect line equipment from the LTP MAPlevel to isolate the error. Refer to Line Maintenance Guide, 297-1001-594for diagnostic tests that can run on line equipment. The system generatesLINE100 or LINE101.

• The system can continue to generate LINE100 (PASS) and ALT104 forthe suspect line equipment. If the system generates LINE100(PASS)and ALT104 during the two retests of ALT failures, contact the nextlevel of maintenance.

• If the system generates LINE101 (FAIL), follow the action required forLINE101.

Continue attempts to clear the error until one of the following occurs:

• The system generates LINE100 and does not generate ALT104.

• You contacted the next level of maintenance.

AttributesAttribute Value

Severity Indeterminate

ALT104 159

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 160: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FormatALT104 mmmdd hh:mm:ss ssdd FAIL ALT

len DN dn cycltxt

LIT TEST = testtxt RESULT: restxt

MIN nnn OHMS ACT nnn OHMS

Selected field descriptionsField Value Fixed or

VariableDescription

FAIL ALT Constant Fixed Indicates a fail automatic line test(ALT) performed.

len Alphanumeric textstring

Variable The line equipment number (LEN) forsuspect line equipment

DN Constant Fixed Indicates that a directory number (DN)follows

dn Integers Variable The directory number (DN) for thesuspect line equipment

cycltxt 1st CYCLE Variable Indicates line equipment failed thespecified test the first time the testran.

RETEST 1 Variable Indicates line equipment failed thespecified test during the automaticretest of ALT 1st CYCLE failures.

RETEST 2 Variable Indicates line equipment failed thespecified test during the automaticretest of ALT RETEST 1 failures.

ALL TEST Variable Indicates that the suspect lineequipment performed all of the teststhat followed.

CAPACITANCE Variable Measures capacitance valuesbetween tip lead and ground, ring leadand ground, and tip and ring leads.

FEMF Variable Measures ac/dc foreign electromotiveforce (FEMF) between tip lead andground, and ring lead and ground.

R-G Variable Measures insulation resistancebetween ring lead and ground.

R-T Variable Measures insulation resistancebetween ring and tip leads.

160 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 161: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

T-G Variable Measures insulation resistancebetween tip lead and ground.

RESULT RING LEAK Variable Indicates that insulation resistancemeasured between ring lead andground is lower than minimumrequired.

TIP LEAK Variable Indicates insulation resistancemeasured between tip lead andground is lower than minimumrequired.

TIP RNG LEAK Variable Indicates insulation resistancemeasured between tip and ring leadsis less than minimum required

MIN nnn OHMS 1 to 7500 Variable Defines minimum insulation resistancein Ohms that suspect line equipmentrequires. The default value for band 0is 400 and for band 1 is 2000. Whenthe system defines the ALT test, youcan use the DEFINE command in theALT MAP level to change the default.

ACT nnn OHMS 0 to 32767 Variable Provides current insulation resistancein Ohms measured on the line

Active message exampleALT104 APR01 12:00:00 2112 FAIL ALT

HOST 01 1 01 01 DN 8057811999 1st CYCLE

LIT TEST = ALL TEST RESULT: TIP-RNG LEAK

MIN 400 OHMS ACT 100 OHMS

Clear message examplen/a

Associated OM registers

ALT105The Automatic Line Testing (ALT) subsystem log report ALT105. Thesubsystem generates ALT105 when the line circuit pack and the testequipment cannot make the metallic test access (MTA). Normally, youcannot make this connection because the MTA vertical for the line circuit

ALT105 161

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 162: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

pack is not available. ALT performs as a result of a manual request fromthe ALT MAP level or based on the ALT schedule See ALT MAP level forschedule.

ALT can perform on separate lines. ALT normally performs on knowngroups of lines. The DMS switch automatically tests each line that fails thefirst run of ALT again. The DMS switch automatically tests each line thatfails during the second run of ALT again. When the line that the reportidentifies and the test equipment cannot make the MTA, the systemgenerates ALT105. Refer to the Line Maintenance Guide, 297-1001-594for more information on ALT.

Remedial actionRerun test from the ALT MAP level. If the system generates ALT105 twicewith the same LEN, verify if another test runs that uses the MTA vertical.

• If the system runs another test, wait until the test is complete and runthe ALT test for the suspect line equipment again. If the systemgenerates ALT105 a third time, contact the next level of maintenance.

• If the system does not run another test, contact the next level ofmaintenance.

Continue attempts to clear the error until one of the following occurs:

• The system does not generate ALT105.

• You contacted the next level of maintenance.

AttributesAttribute Value

Severity Indeterminate

FormatALT105 mmmdd hh:mm:ss ssdd FAIL ALT

len DN dn cycltxt

LINE TEST ACCESS FAILED

Selected field descriptionsField Value Fixed or

VariableDescription

FAIL ALT Constant Fixed Indicates a fail ALT attempted.

len Alphanumeric textstring

Variable The line equipment number (LEN) forthe suspect line equipment

162 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 163: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

DN Constant Fixed Indicates that a directory number (DN)follows

dn Integers Variable The directory number (DN) for thesuspect line equipment

cycltxt 1st CYCLE Variable Indicates line equipment failed thespecified test the first time the testran.

RETEST 1 Variable Indicates line equipment failed thespecified test during the automaticretest of ALT first CYCLE failures.

RETEST 2 Variable Indicates line equipment failed thespecified test during the automaticretest of ALT RETEST 1 failures.

LINE TEST ACCESSFAILED

Constant Fixed Indicates that line circuit pack and testequipment did not make MTAconnection.

Active message exampleALT105 APR01 12:00:00 2112 FAIL ALT

HOST 01 1 01 01 DN 8057811999 1st CYCLE

LINE TEST ACCESS FAILED

Clear message examplen/a

Associated OM registers

ALT106The Automatic Line Testing (ALT) subsystem report ALT106. The systemgenerates ALT106 when a line insulation test (LIT) that measures thecapacitance for AC continuity on line equipment fails. ALT measures thecurrent capacitance per nanofarad. ALT compares the current capacitanceto the minimum capacitance required on the line. The system performsALT as a result of either a manual request from the ALT MAP level orbased on the ALT schedule. Refer to the ALT MAP level for schedule.

ALT can perform on separate lines. ALT normally performs on knowngroups of lines. The DMS automatically tests each line that fails the firstrun of ALT again. The DMS automatically tests each line that fails during

ALT106 163

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 164: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

the second run of ALT again. The system generates ALT106 when the linethat the report identifies by its LEN and DN fails. Refer to the LineMaintenance Guide, 297-1001-594 for more information on ALT.

Remedial actionPerform line diagnostics on the suspect line equipment from the LTP MAPlevel to isolate the fault. The system generates either LINE100 or LINE101.

• The system can continue to generate LINE100 (PASS) and ALT106 forsuspect line equipment. If the system generates LINE100 (PASS) andALT106 during the two retests of ALT failures, contact the next level ofmaintenance.

• If the system generates LINE101 (FAIL), follow the action the systemtakes for LINE101.

Continue attempts to clear the error until one of the following occurs:

• The system generates LINE100 and does not generate ALT106.

• You contacted the next level of maintenance.

AttributesAttribute Value

Severity Indeterminate

FormatALT106 mmmdd hh:mm:ss ssdd FAIL AC_CONTINUITY

len DN dn cycltxt

LIT TEST = 1ttxt RESULT: restxt

MIN nnn NF ACT nnn NF

Selected field descriptionsField Value Fixed or

VariableDescription

FAILAC_CONTINUITY

Constant Fixed Indicates a fail AC continuity testperformed.

len Alphanumeric textstring

Variable The line equipment number (LEN) forthe suspect line equipment

DN Constant Fixed Indicates that a directory number (DN)follows

dn Integers Variable The directory number (DN) for thesuspect line equipment

164 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 165: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

cycltxt 1st CYCLE Variable Indicates line equipment failed thespecified test the first time the testran.

RETEST 1 Variable Indicates line equipment failed thespecified test during the automaticretest of ALT first CYCLE failures.

RETEST 2 Variable Indicates line equipment failed thespecified test during the automaticretest of ALT RETEST 1 failures.

LIT TEST ALL TEST Variable Indicates foreign electromotive force(FEMF), insulation resistance, andcapacitance tests performed onsuspect line equipment.

CAPACITANCE Variable Measures capacitance valuesbetween tip lead and ground, ring leadand ground, and tip and ring leads.

RESULT CAPACITANCE Variable Indicates capacitance measuredbetween tip lead and ground, ring leadand ground, or tip and ring leads waslower than minimum required.

MIN nnn NF 1 to 5000 Variable Defines minimum capacitance(nanofarad) required on a line. Thedefault is 400.

ACT nnn NF 0 to 32767 Variable Provides current capacitance(nanofarad) measured on suspect lineequipment

Active message exampleALT106 APR01 12:00:00 2112 FAIL AC_CONTINUITY

HOST 01 1 01 01 DN 8057811999 1st CYCLE

LIT TEST = FEMF RESULT: CAPACITANCE

MIN 400 NF ACT 100 NF

Clear message examplen/a

ALT106 165

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 166: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ALT107The Automatic Line Testing (ALT) subsystem log report ALT107. Thesubsystem generates ALT107 when the system detects a problem at thestart of or in the middle of an automatic line test. The following three unitscan be present in the same configuration:

• a Multi-line Test Unit (MTU)

• a Line Test Unit (LTU)

• an Integrated Remote Test Unit (IRTU)

ALT generates the appropriate report for the condition that the test meets.ALT identifies the unit that conducted the test as either LTU, MTU, orIRTU.

This section describes trouble reasons given in the Reason field of logreport ALT107.

Test equipment fails diagnostic - Test equipment name

• The test equipment described in the INFO text failed diagnostics. Atrunk diagnostic fail reason TRK106 log accompanies this log.

Test equipment unavailable - Test equipment name

• The test equipment or test equipment that the INFO text describes isnot available.

TTT usage percentage exceeded.

• Indicates you exceeded the usage percentage of the trunk testequipment.

External equipment problem - Vertical not seized

• Indicates the system attempted to use the metallic test access (MTA)data to make a connection. The system must seize the MTA vertical forthe line concentration device (LCD) test set. This action makes sureother users cannot use the vertical. The attempt to connect failsbecause the vertical is already in use.

Vertical data missing

• Indicates system attempts to use the MTA data to make a connection.The MTAVERT data is not in the LCD test set any longer.

166 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 167: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

LTA connection

• Indicates the system attempts to use MTA data to make a connection.An MTA crosspoint connection fails because of physical connectionproblems or because the vertical is in use.

Unable to do TEST EQ diagnostic - Test equipment name

• Indicates the system did not perform the test equipment diagnostic.

Diagnostic result message - Test equipment name

• Indicates the test equipment diagnostic result message did not return intwo minutes.

ALT test processes exceeded - Blank

• A request to activate a scheduled test occurred. The number of testprocesses now active plus the test processes required for the newrequest exceeds the total number allowed.

Test stopped - Blank

• Testing stopped for the given TESTID.

LCD test set suspended.

ssss ff u dd, cc - ssss ff, u dd cc - The system suspended the test set thatthe range of line equipment numbers indicates. The high number of failuresthat were a result of an external error that was not known caused thesuspension.

Test stream suspended - Blank or Death test process

• Indicates if more failures can result if system continues the test stream.

LTP interrupt - Blank

• Indicates that another testing process that can interrupt the vertical ofthe MTA interrupted the system.

LCD test set store not available - Blank

• Indicates temporary store is not available for store test information.

The following table lists system and user actions for trouble reasons givenin the Reason field of log report ALT 107.

This section shows the system and user action.

ALT107 167

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 168: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Test equipment fails diagnostic.

• System action - The ALT system diagnoses the failed test equipmentevery 30 m. Test resumes if the diagnostic passes.

• User action - For ALT to continue testing, the test equipment must passdiagnostics and be IDL or INI. The PM must be in service.

Test equipment unavailable

• System action - The ALT system attempts to seize the test equipmentrequired to resume testing after 30 m.

• User action - Make test equipment available to allow ALT to run.

External equipment problem

• System action - The ALT system attempts to get the MTA connectionevery 30 m to resume testing.

• User action - Make MTA equipment available to allow ALT to run.Connections that require the MTA data must be available.

Unable to do TEST EQ diagnostic.

• System action - The ALT system attempts to diagnose the testequipment every 30 m. Testing continues if the diagnostic passes.

• User action - If this problem continues, contact the next level ofmaintenance.

Diagnostic result message

• System action - The ALT system attempts to diagnose the testequipment every 30 m. Testing continues if the diagnostic passes.

• User action - If this problem persists, contact the next level ofmaintenance.

ALT test processes exceeded

• System action - The ALT system does not attempt to create a testprocess for the stream in this test session.

• User action - Check the schedule times. Make sure you do not requesttoo many test processes. You can recalculate office parameter ALT NOOF ALT TEST PROCS. The office has expanded.

Test stopped

• No system action.

• User action - The user stopped the test. The user can start the testagain.

168 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 169: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

LCD test set suspended.

• System action - Testing suspended until the next test session.

• User action - Line cards on the LCD test set fail continuously. Performmanual tests to determine the possible reason for the high number offailures. Test the MTA driver and vertical test access bus connections.Check for cable cuts.

Test stream suspended

• System action - Testing suspended until the next test session.

• User action - Line cards on the LCD test set fail continuously. Performmanual tests to determine the reason for the high number of failures.Test the MTA driver and vertical test access bus connections. Checkfor cable cuts. If the INFO text is "death of test process", contact thenext level of maintenance.

LTP interrupt

• System action - After 30 m, the system attempts to seize the testequipment and continue test.

• User action - There is no user action required.

LCD test set store not available

• System action - After 30 m, the system attempts to seize the testequipment and continue test.

• User action - The switch can have serious problems because of lack ofstore. Contact the next level of maintenance.

Remedial actionRefer to the user action specified for the given trouble reason in theSystem and User Actions table. The trouble reason table appears at theend of this log report.

AttributesAttribute Value

Severity Warning

FormatALT107 mmmdd hh:mm:ss ssdd TBL

TESTID: testxt STREAM: nnn Test type: typtxt

REASON = trbltext

ALT107 169

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 170: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

INFO =infotext

Selected field descriptionsField Value Fixed or

VariableDescription

TBL TESTID Alphanumeric Variable Identifies a trouble condition in anautomatic line test. Can be a name incustomer data Table ALTSCHED orthe name of a manual test

STREAM 0 -31 Variable Identifies the stream

Test type DIAG Variable Identifies a diagnostic test

SDIAG Variable Identifies a short diagnostic test

BAL NET Variable Identifies an on-hook balance networktest

LIT Variable Identifies a line insulation test

CKTTST Variable Identifies a circuit test

REASON Character string Variable Provides the reason for the problem.Refer to Trouble reasons table at theend of this log report.

INFO Symbolic text Variable Provides additional information. Referto Trouble reasons table at the end ofthis log report.

Active message exampleALT107 JUL06 15:55:09 0600 TBL ALT

TESTID: MANUAL04 STREAM: 0 Test type: LIT

REASON = Test equipment unavailable

INFO = IRTU 1

ALT107 JAN27 04:05:06 3445 TBL

TESTID: LNMTCJOHN STREAM: 10 Test type:

DIAG

REASON = Test equipment fails diagnostic

INFO = LTU 0

Clear message examplen/a

170 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 171: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ALT108The Automatic Line Testing (ALT) subsystem log report ALT108. Thesubsystem generates ALT108 to report on results from a line concentratingdevice (LCD) test set. ALT108 is a summary of information given in logALT109. The system generates ALT108 or ALT109 depending on a fieldsetting in customer data Table ALTSCHED for each test id. The systemgenerates ALT108 or ALT109 depending on the parameter on the STARTcommand for manual tests.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatALT108 mmmdd hh:mm:ss ssdd INFO

TESTID: testxt Stream: nnn Test type: typtxt Linetype: ltype

LCD test set: ssss ff u dd ll -- ssss ff u dd ll

PASS FAIL N/A TOTAL

nnnnnn nnnnnn nnnnnn nnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

INFO TESTID: testxt Entered in customerdata TableALTSCHED, or thename of a manualtest.

Variable Identifies the automatic line test.

STREAM: nnn 0-31 Variable Identifies the test stream.

typtxt DIAG Variable Identifies a diagnostic test.

SDIAG Variable Identifies a short diagnostic test.

BAL NET Variable Identifies an on-hook balance networktest.

LIT Variable Identifies a line insulation test.

ALT108 171

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 172: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

CKTTST Variable Identifies a circuit test.

ltype Standard ISDN Variable ALL

Identifies the line types tested.

ssss ff u dd cc Symbolic text Variable Identifies the line equipment numberrange for the LCD test set. Refer toTable 1.

nnnnnn 0-999999 Variable Provides a count of the number ofpassed, failed, not applicable, andtotal tests.

Active message exampleALT108 APR10 00:12:23 5764 INFO

TESTID: LNMTCJOHN Stream: O Test type: SDIAG Linetype:ALL

LCD test set: HOST 00 0 00 00 - HOST 00 0 09 31

PASS

FAILN/A

TOTAL2451164320

Clear message examplen/a

Associated OM registers

ALT109The automatic Line Testing (ALT) subsystem log report ALT109. Thesubsystem generates ALT109 when a line insulation test (LIT) fails.

Remedial actionUse this log to identify problem LENs that had problems when ALT testedthe LCD test set.

172 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 173: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity • Warning

• Major

• Minor

FormatALT109 mmmdd hh:mm:ss ssdd INFO

TESTID: testxt STREAM: nnn Test type: typtxt Linetype: 1type

PASS FAIL N/A TOTAL part a of b

nnnnnn nnnnnn nnnnnn nnnnnn

============================================================

LCD test set: ssss ff u dd cc - ssss ff u dd cc

=============================================

0000 0000 0011 1111 1111 2222 2222 2233

0123 4567 8901 2345 6789 0123 4567 8901

===============================================

mm rrrr rrrr rrrr rrrr rrrr rrrr rrrr rrrr

nn rrrr rrrr rrrr rrrr rrrr rrrr rrrr rrrr

===============================================

oo rrrr rrrr rrrr rrrr rrrr rrrr rrrr rrrr

pp rrrr rrrr rrrr rrrr rrrr rrrr rrrr rrrr

===============================================

. rrrr rrrr rrrr rrrr rrrr rrrr rrrr rrrr

. rrrr rrrr rrrr rrrr rrrr rrrr rrrr rrrr

===============================================

ALT109 173

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 174: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

uu rrrr rrrr rrrr rrrr rrrr rrrr rrrr rrrr

vv rrrr rrrr rrrr rrrr rrrr rrrr rrrr rrrr

Selected field descriptionsField Value Fixed or

VariableDescription

INFO TESTID Symbolic text Variable Identifies the test performed. Enteredin customer data Table ALTSCHED orthe name of a manual test.

STREAM 0-31 Variable Provides stream number.

typtxt DIAG Variable Identifies a diagnostic test.

SDIAG Variable Identifies a short diagnostic test.

BAL NET Variable Identifies an on-hook balance networktest.

LIT Variable Identifies a line insulation test.

CKTTST Variable Identifies a circuit test.

1type Standard Variable Identifies the line type tested.

ISDN Variable

All Variable

Part a of b a and b are integers. Variable Indicates the part of this log for theLLCD test set size. Each ALT109 logreport can contain a maximum of 12drawers.

n Integers Variable Indicates the device number of theterminal. Refer to table TERMDEV inthe customer data schema section ofthe Translations Guide .

nnnnnn 0-999999 Variable Provides the number of passed, failed,not applicable, or total tests.

r . Variable Indicates line EQ passed diagnostictest.

(blank) Variable Indicates not part of diagnostic test.

D Variable Diagnostic failed.

F Variable Diagnostic failed because of facility.

S Variable Short diagnostic failed.

N Variable Needs long diagnostic.

m Variable Set or NT1 is not available.

M Variable Line card missing.

174 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 175: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Variable For the RDT, Remote Digital Terminal,an unseated or missing line card isreported as *not as M.

Q Variable Shower queue.

l Variable Incoming message overload (ICMO)major.

i Variable ICMO minor

U Variable Utility card.

T Variable System seized line when systemgenerated log.

- Variable Not entered in table LNINV.

* Variable Skipped lines because of LEN linestate, LINETYPE of test, or failure tooperate ISDN linecard relays duringLIT test.

Variable For the RDT, Remote Digital Terminal,a line card out of service or missing isreported as *not M.

/ Variable ALT tests not performed on the LENsbecause test met the stop time for thistime span. The system tested lineequipment numbers in a differentscheduled time span.

h Variable Held because of equipment problem.This value represents the state at timeof log generation. Next scheduled timespan for TESTID starts at first h LEN.

s Variable Suspended because of equipmentproblem. This value represents thestate at time of log generation.

@ Variable Indicates line insulation test (LIT)result failed for this line equipmentnumber (LEN).

c Variable Indicates a connection error occurredwhen the system attempted a trunktest equipment connection.

e Variable Indicates the system detected anexternal error when the system madea metallic connection. An example ofthis failure is a test access relayfailure.

ALT109 175

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 176: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleALT109 APR23 23:59:23 5700 INFO

TESTID: LNMTCJOHN STREAM: 9 Test type: DIAG Linetype:ALL

type: line typetxt

PASS FAIL N/A TOTAL part 1 of 1

142 165 9 316

=============================================

LCD test set: HOST 00 0 00 05 - HOST 00 0 04 31

========================================

0000 0000 0011 1111 1111 2222 2222 2233

0123 4567 8901 2345 6789 0123 4567 8901

========================================

00 /// //// //.. D.-- --N. .... ....

01 .... .... .... .... .... .... .... ....

========================================

02 .... *... .... .... .... .... .... ....

03 .... .... .... **.. .... .... .... ....

========================================

04 .... .... .... .... .... .... .... ....

Clear message examplen/a

Associated OM registers

ALT110The Automatic Line Testing (ALT) subsystem generates ALT110 when thesystem completes a test stream. This report provides counts for a streamcompletion.

176 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 177: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatALT110 mmmdd hh:mm:ss ssdd INFO

TESTID: testxt Test type: typtxt Linetype: 1type

Stream nnn completed

PASS FAIL N/A TOTAL

nnnnnn nnnnnn nnnnnn nnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

INFO TESTID: testxt Entered in customerdata TableALTSCHED, or canbe the name of amanual test.

Variable Identifies the test name.

typtxt DIAG Variable Identifies a diagnostic test.

SDIAG Variable Identifies a short diagnostic test.

BAL NET Variable Identifies an on-hook balance networktest.

LIT Variable Identifies a line insulation test.

CKTTST Variable Identifies a circuit test.

1type Standard Variable Identifies the line type that was tested.

ISDN Variable

All Variable

Stream nnncompleted

0-31 Variable Identifies the test stream.

nnnnnn 0-999999 Variable Provides the number of passed, failed,not-applicable, or total tests.

Active message exampleALT110 APR13 06:01:10 4514 INFO

ALT110 177

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 178: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

TESTID: LNMTCJOHN Test type: BAL NET Linetype: Standard

Stream 4 completed

PASS FAIL N/A TOTAL

1239 23 101 1363

Clear message examplen/a

Associated OM registers

ALT111The Automatic Line Testing (ALT) subsystem generates ALT111 when thesystem completes a line test. The subsystem also generates ALT111 toprovide a progress update of the test. The system generates a completionlog when the system completes all test streams. The system generates aprogress update on expiration of the test time for a scheduled test.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatALT111 mmmdd hh:mm:ss ssdd INFO

TESTID: testxt Test type: typtxt Linetype: 1type

infotxt

PASS FAIL N/A TOTAL

nnnnnn nnnnnn nnnnnn nnnnnn

178 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 179: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFO TESTID: testxt Entered in customerdata TableALTSCHED, or canbe the name of amanual test.

Variable Identifies the test name.

typtxt DIAG Variable Identifies a diagnostic test.

SDIAG Variable Identifies a short diagnostic test.

BAL NET Variable Identifies an on-hook balance networktest.

LIT Variable Identifies a line insulation test.

CKTTST Variable Identifies a circuit test.

1type Standard Variable Identifies the line types that weretested.

ISDN Variable

All Variable

infotxt Completed TESTID Variable Indicates the test is complete.

Progress update Variable Indicates the test time for a scheduledtest expired.

nnnnnn 0-999999 Variable Provides the number of passed, failed,not-applicable, or total tests.

Active message exampleTESTID: LNMTCISDN Test type: LIT Linetype: ISDN CompletedTESTID.

PASS FAIL N/A TOTAL

54 10234 1023 11311

Clear message examplen/a

Associated OM registers

ALT112The ALT112 log identifies line equipment numbers (LEN) that are notdatafilled in table ALTSCHED and therefore are not scheduled forAutomatic Line Insulation Test (ALIT). ALT112 also includes hardwareassigned software unassigned (HASU) lines.

ALT112 179

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 180: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Office parameter ALIT_LOG_GEN_FREQ controls the frequency of loggeneration.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatREPNAME TYPE EVENT WORDS ALARMS SUP RTD LAB OWNER

======================================================================

ALT112 INFO ALTSCHED_NOT_DATAFILLED 50 NO ALARMS NO YES NOALTLOGUI

Formatting proc bound: ALTGUI.FORMAT_A #0676 #B2A0

Selected field descriptionsField Value Fixed or

VariableDescription

STARTLEN LEN Variable STARTLEN of any contiguous block ofLENs that are not datafilled in tableALTSCHED.

ENDLEN LEN Variable ENDLEN of any contiguous block ofLENs that are not datafilled in tableALTSCHED.

Active message exampleINDY0_US10BO ALT112 MAR09 19:25:56 5300 INFOALTSCHED_NOT_DATAFILLED

Refer to the log ALT113 for a list of PMs which

do not have verticals assigned in table MTAVERT

start_len end_len

HOST 01 0 02 06 HOST 01 1 11 24

INDY0_US10BO ALT112 MAR09 20:11:08 3100 INFOALTSCHED_NOT_DATAFILLED

180 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 181: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Refer to the log ALT113 for a list of PMs which

do not have verticals assigned in table MTAVERT

start_len end_len

HOST 01 0 02 06 HOST 01 1 11 24

HOST 01 1 02 22 HOST 01 1 11 24

HOST 01 0 03 11 HOST 01 0 03 14

ALT112 log continued from the previous report

INDY0_US10BO ALT112 MAR09 20:11:08 3000 INFO ALTSCHED_NOTDATAFILLED

Refer to the log ALT113 for a list of PMs which

do not have verticals assigned in table MTAVERT

start_len end_len

HOST 01 0 02 06 HOST 01 0 02 08

HOST 01 0 02 22 HOST 01 0 03 04

HOST 01 0 03 11 HOST 01 0 03 14

HOST 01 0 03 22 HOST 01 0 03 24

HOST 01 0 08 06 HOST 01 0 08 04

HOST 01 0 08 00 HOST 01 0 08 14

HOST 01 0 08 11 HOST 01 0 09 04

HOST 01 0 09 22 HOST 01 1 00 04

HOST 01 1 00 11 HOST 01 1 00 14

HOST 01 1 00 22 HOST 01 1 01 04

HOST 01 1 01 11 HOST 01 1 01 14

HOST 01 1 01 22 HOST 01 1 02 04

ALT112 181

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 182: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

ALT113The ALT113 log identifies peripheral modules (PM) that are not datafilled intable MTAVERT and therefore do not have access to test equipment.

Office parameter ALIT_LOG_GEN_FREQ controls the frequency of loggeneration.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatREPNAME TYPE EVENT WORDS ALARMS SUP RTD LAB OWNER

=======================================================================

ALT113 INFO MTAVERT_NOT_DATAFILLED 14 NO ALARMS NO YES NOALTLOGUI

Formatting proc bound: ALTGUI.FORMAT_ALT_113 #0893 #EDCC

Selected field descriptionsField Value Fixed or

VariableDescription

Module Numbers Module numbers Variable Module numbers from table LNINVthat are not datafilled in tableMTAVERT and therefore do not haveaccess to test equipment.

Active message exampleINDY1CDN10BO ALT113 MAR10 13:24:05 3200 INFOMTAVERT_NOT_DATAFILLED

MODULE NUMBERS

182 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 183: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

HOST 01 1

INDY1CDN10BO ALT113 MAR10 13:24:05 3200 INFOMTAVERT_NOT_DATAFILLED

MODULE NUMBERS

HOST 04 1

ALT113 log continued from the previous report

INDY1CDN10BO ALT113 MAR10 13:24:05 3200 INFOMTAVERT_NOT_DATAFILLED

MODULE NUMBERS

HOST 01 0

HOST 01 1

HOST 02 0

REM1 01 0

REM1 01 1

HOST 03 0

HOST 03 1

REM2 01 0

REM2 01 1

REM2 02 0

REM2 02 1

HOST 04 0

Clear message examplen/a

ALT113 183

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 184: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ALT200Log ALT200 is an automatic line testing (ALT) failure (FAIL) log. Thesystem generates this FAIL log when results of running a board-to-boardtest (BBT) session on a line indicate a failure. The system generates threetypes of logs when an ALT is in progress:

• failure (FAIL)

• trouble (TBL)

• information (INFO)

The system modifies the ADD_LOG in table ALTTCIPL to include the newlog ALT200. The system generates this log when a user invokes theSTART command from the BBT-maintenance and administration position(MAP) level. But, the system only generates a log if the test fails on a line.

The LEN or the DN in the log discovers the line on which the system failsthe test. The following table explains the possible failure reasons referredto in the Failure field description from the above table.

This section shows the failure reasons and their correspondingdescriptions.

• Tip and Ring reversal - Indicates that the Tip and Ring leads of the oldand new lines are reversed. In the occurrence of a step-by-step (SxS)old office, this can indicate mismatched party types.

• Class test failed - Indicates data that the data points to a private branchexchange (PBX) line. Either the automatic board-to-board test (ABBT)results disagree or the new and old offices disagree on when the line isTip or Ring party.

• Start test failed - Indicates that a start fault is present. For example, theline is loop start according to the new office data. But, it is equipped asground start in the old office.

• Tip open Ring open REV - Indicates that the line condition is Tip open.

• Ring open Tip open REV - This reason indicates that the line conditionis Ring open.

• Tip and Ring open - Indicates that the line condition is Tip open.

184 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 185: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• Tip or Ring ground - Indicates that there may be a Tip groundcondition. In the occurrence of an SxS office, this indicates a short onan idle Tip party line.

• Tip or Ring short - Indicates that there may be a Tip and Ring shortcondition. In the occurrence of an SxS office this indicates a Tip groundcondition on a busy party line. There can also be a Ring groundcondition.

Remedial actionThere is no action required. The failure reason table below can help toindicate the problem.

AttributesAttribute Value

Severity Warning

FormatALT200 mmmdd hh:mm:ss ssdd FAIL ALT

len DN dn

TESTID: testxt TEST-TYPE: tsttype

Failure: failure reason

Selected field descriptionsField Value Fixed or

VariableDescription

dn Integers Variable The directory number (DN) for thesuspect line equipment

TESTID alphanumeric (12characters)

Variable Test identification. This field indicatesthe test id name.

TEST TYPE BASIC, START,CLASS, or ALL

Variable Test type. This field indicates the BBTtest type.

Failure alphanumeric (48characters)

Variable Failure. This field indicates the reasonfor the failure. Refer to the table belowfor detailed descriptions of eachpossible failure reason.

FAIL ALT constant Variable Fail automatic line testing. This fieldindicates the log type. The systemgenerates FAIL ALT when a board-to-board test on a line indicates a failure.

ALT200 185

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 186: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

len Alphanumeric textstring

Variable Line equipment number (LEN). Thisfield specifies the LEN of the line to betested.

DN Constant Fixed Indicates that a directory number (DN)follows

Active message exampleATL200 JAN05 15:19:17 0600 FAIL ALT

HOST 65 0 00 06 DN: 6136213000

TESTID: MANUAL37 TEST-TYPE: BASIC

Failure: Tip and Ring open.

Clear message examplen/a

Associated OM registers

ALT209Log ALT209 after an automatic line testing (ALT) board-to-board test (BBT)session tests a TESTID. This log provides a detailed status of the testedlines that include:

• a four-character test results identifier

• what was tested in this test session

• the ABBTSET used

• the test performed in BY-DN or BY-LEN format

• the type of ALTBBT test performed

The ADD_LOG in table ALTTCIPL now includes log ALT208 and logALT209 now contains ADD_REPORT_TYPE. The log invokes the STARTcommand from the BBT Map level to generate log ALT209.

The four letter result codes referred to in the field description table and inthe Action section are listed below. The list includes explanations andrequired actions.

186 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 187: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

This section shows the result codes, its explanations and the actions to betaken.

• UNAS - Indicates that there is no line equipment that corresponds tothe specified DN.

• TAFL - Indicate a bad horizontal, a bad vertical, a hardware failure, abusy horizontal, or a busy vertical. The end user must specify enoughcolumns to access all the verticals used by this automatic board-to-board test (ABBT) test unit. The end user must verify the number of therow and horizontal assigned to the ABBT test unit. The end user mustverify that the metallic test access driver (MTADRIVER) in the MTA unitfunctions.

• OPFL - Indicates that the cause is a stop-dial from the old office duringoutpulsing. Either the connections to the outgoing (OG) trunk, orinformation specified for the trunk is not correct. The end user mustmake sure the type of start signal for the no-test trunk is correct. Theend user must make sure the trunk is in the returned-to-service (RTS)state.

• SEZF - This code indicates a problem in the seizure protocol. Checkthe connection between the outpulsing trunk (along the BBT testcircuits) and the test trunk or its equivalent. The end user can reversethe setting of the REV button on the ABBT test set. The end user cancheck the wiring from the OG trunk card to the old office.

• TOFL - This code indicates that the system cannot connect to the oldoffice. The end user can verify that the old DN is the correct type andtry the test again. The end user can verify if the disconnect time iscorrect.

• MTAO - This code indicates that the system cannot connect throughthe MTA of the switch to access the new line. Attempts to connect failwhen the crosspoints of the MTA associated with that line are busy.Using Len order to conduct the testing order can solve this problem.

• TR_R - This code indicates that the Tip and Ring leads of the old andnew lines are in reverse. In the example of a step-by-step (SxS) oldoffice, this reason can indicate mismatched party types.

• CLSF - This code signifies that the data indicates a private branchexchange (PBX) line, but the ABBT results disagree.

• PARF - This code indicates that the new and old offices disagree onwhether the line are Tip or Ring party. If the problem occurs often, theend user should make sure the voltage setting of the variable battery iscorrect.

ALT209 187

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 188: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• STRF - This code indicates that the line may be a loop start accordingto new office data. The problem is that this line is equipped as a groundstart in the old office. If the problem occurs often, the end user shouldmake sure the voltage setting of the variable battery is correct.

• ABSC - This code indicates that the end user should make sure thevoltage setting of the variable battery is correct.

• BSYS - This code indicates that the end user should check that thenew line is in the cutoff condition. The end user should also check thatthe Tip and Ring voltage in the old office is set to the correct value.

• TROR - This code indicates that the line condition is Tip open.

• RTOR - This code indicates that the line condition is Ring open.

• TROP - This code indicates a Tip Ring open condition.

• TRGR - This code indicates that there may be a Tip ground condition.In the example of an SxS office, this result indicates a short on an idleTip party line.This code indicates that there may be a Tip groundcondition. In the example of an SxS office, this result indicates a shorton an idle Tip party line.

• TRSH - This code indicates that there may be a Tip and Ring shortcondition. In the example of an SxS office, this result indicates a Tipground condition on a busy party line. There may be a Ring groundcondition also.

Remedial actionThe action required depends on the result code. Refer to the result codetable below for explanations and actions.

AttributesAttribute Value

Severity Warning

FormatALT209 mmmdd hh:mm:ss ssdd INFO ALT

TESTID testid name TEST TYPE: test type Order: test order

PASS FAIL N/A TOTAL

nnnn nnnn nnnn nnnnn

===========================================================

Range: LEN ssss ff b dd ll - ssss ff b dd ll

188 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 189: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

DN nnn-nnn-nnnn - nnn-nnn-nnnn

===========================================================

0 1 2 3 4 5 6 7 8 9

===========================================================

nnny NTST NTST NTST NTST NTST NTST NTST -- -- --

nnny -- -- -- -- -- -- -- -- -- --

nnny -- -- -- -- -- -- -- -- -- --

nnny -- -- -- -- -- -- -- -- -- --

nnny -- -- -- -- -- -- -- -- -- --

nnny -- -- -- -- -- -- -- -- -- --

nnny -- -- -- -- -- -- -- -- -- --

nnny -- -- -- -- -- -- -- -- -- --

nnny -- -- -- -- -- -- -- -- -- --

nnny -- -- -- -- -- -- -- -- -- --

Selected field descriptionsField Value Fixed or

VariableDescription

INFO ALT constant Variable Information automatic line testing(ALT). This field indicates the log type.The field summarizes the results of anALT BBT session.

TESTID alphanumeric (12characters)

Variable Test identification. This field indicatesthe test id name.

TEST TYPE ALL, BASIC, CLASS,or START

Variable Test type. This field specifies the BBTtest type.

Order By-LEN or By-DN Variable Order. This field indicates the testorder defined for the test id.

LEN numeric (48characters)

Variable Line equipment number. This fieldspecifies the LEN of the tested line. Ifthe test order is By-LEN, the start LEN

ALT209 189

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 190: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

and the end LEN are displayed. If thetest order is By-DN, ************* *isdisplayed.

DN numeric (48characters)

Variable Directory number. This field specifiesthe DN of the tested line.

PASS numeric Variable Pass. Tested lines that are successfulare indicated in this field.

FAIL numeric Variable Fail. This field indicates the number oflines on which the test failed.

N/A numeric Variable Not attempted. Lines that are nottested are indicated in this field.

TOTAL numeric Variable Total. This field indicates the totalnumber of lines defined for the testid.

four_let_code alphabetic Variable Four letter result code. This fieldindicates a four letter result code foreach line tested. Lines that are nottested will display spaces. Successfultests display TSOK (test okay). Referto the result table below forexplanations of the possible codes.

Active message exampleATL209 JAN05 13:22:33 2200 INFO ALT

TESTID:MANUAL37 TEST TYPE:Basic ORDER:By-DN

PASS FAIL N/A TOTAL part 1 of 1

========================================================

5 2 0 7

Range : LEN * * * * * * * * * * * * * *

DN 613-621-3000 -- 613-621-3006

========================================================

0 1 2 3 4 5 6 7 8 9

======================================================

300Y TSOK TSOK TSOK TSOK TSOK TSOK TSOK -- -- --

190 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 191: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

301Y -- -- -- -- -- -- -- -- -- --

302Y -- -- -- -- -- -- -- -- -- --

303Y -- -- -- -- -- -- -- -- -- --

304Y -- -- -- -- -- -- -- -- -- --

305Y -- -- -- -- -- -- -- -- -- --

306Y -- -- -- -- -- -- -- -- -- --

307Y -- -- -- -- -- -- -- -- -- --

308Y -- -- -- -- -- -- -- -- -- --

309Y -- -- -- -- -- -- -- -- -- --

Clear message examplen/a

Associated OM registers

ALT300Under the Automatic Line Testing (ALT) subsystem, the line concentratingdevice cutover (LCDCUT) command interpreter program generates anALT300 log. The LCDCUT program is used to cut into service blocks oflines on line concentrating modules (LCM). The LCDCUT program selectsgroups of directory numbers (DN) or line equipment numbers (LEN) whencommissioning a new or expanded office. The results of the LCDCUTcommand executions are output in different logs.

Before a new switch is commissioned, subscriber lines terminate on boththe old and new DMS office. A cutoff (CO) relay is held in the operatedstate for each LEN on the new switch to isolate the DMS switch. Automaticboard-to-board testing (ABBT) procedures verify the subscriber linesbefore to cutover to the new DMS switch.

The CO relay operates at a maximum of 32 lines per drawer and amaximum of 125 lines per LCM at a time. The LCDCUT program maintainsCO relay counters to make sure these limits are not exceeded. Connect anexternal power supply to an LCM to overcome this limit. The CO relayoperation can increase from 125 to 640 lines, depending on the amount ofadditional external power supplied to the LCM.

ALT300 191

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 192: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

When the CO relay reaches its operational threshold limit, the systemgenerates an ALT300 log. The system generates this log while the systemoperates the CO relays for lines defined in a TESTID. The CO relay countsprotect the power converter so that the converter does not trip. A trippedpower converter can cause outages to the in-service lines in the LCM.Outages are a result of operating more CO relays than the acceptable limitfor the unit.

The system generates this log when any of the following thresholds arereached:

• Drawer limit - 32 Non-WLC lines CO relays are already operated on thedrawer.

• Drawer limit - 64 CO relays are already operated.

• LCM limit - 125 Non-WLC lines CO relays are already operated.

• LCM limit - 640 CO relays are already operated.

• SRU or SRU60 limit - 256 CO relays are already operated.

• LCME limit - 512 CO relays are already operated.

If the LCM drawer contains world line cards (WLC), the above powerrestrictions do not apply. The power required to operate the CO relays onWLCs is less than other line cards.

Log history

EUR003

Changed thresholds reached before the system generated an ALT300,include the SRU60.

Remedial actionThe LEN in the log indicates the threshold limit of the LCM (and/or itsdrawer number). Check to see if additional relays are required on an LCMor drawer. Because the CO relays perform on an LCM, additional relaysrequire an added auxiliary power supply to the LCM.

AttributesAttribute Value

Severity Indeterminate

FormatALT300 mmmdd hh:mm:ss ssdd FAIL ALT

192 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 193: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Userid: userid

len DN dn

TESTID: testid

TEST TYPE: LCDCUT

Failure: failure type

Selected field descriptionsField Value Fixed or

VariableDescription

Userid Alphanumeric Variable Identifies the userid of the groupsession that generates the log.

len Alphanumeric textstring

Variable The line equipment number (LEN) forthe suspect line equipment

DN Constant Fixed Indicates that a directory number (DN)follows

dn Integers Variable The directory number (DN) for thesuspect line equipment

TESTID Alphanumeric Variable Identifies the TESTID name.

TEST TYPE LCDCUT Variable Identifies the LCDCUT test.

Failure Symbolic text Variable Indicates the reason for failure.

Active message exampleALT300 APR01 JUN27 08:18:19 5300 FAIL ALT

Userid: Team19

HOST 01 1 01 01 DN 8057811999

TESTID RACHER

TEST TYPE: LCDCUT

Failure: DRW limit 64 CO relays operated

Clear message examplen/a

ALT300 193

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 194: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ALT306The line concentrating device cutover (LCDCUT) command interpreterprogram under the Automatic Line Testing (ALT) subsystem generatesALT306. To cut into service blocks of lines on line concentrating modules(LCM) use the LCDCUT program. The LCDCUT program selects directorynumbers (DN) or line equipment numbers (LEN) when commissioning anew or expanded office. The results of the LCDCUT command executionsare output in different logs.

Before commissioning a new switch, subscriber lines terminate on both theold and new DMS office. A cutoff (CO) relay is held in the operated statefor each LEN on the switch to isolate the DMS switch. Automatic board-to-board testing (ABBT) procedures are performed to verify the subscriberlines prior to cutover to the new DMS switch.

The ALT306 log reports the result of the execution of the HOLDRELcommand from the LCDCUT MAP level under ALT. The parameters of theHOLDREL command are OPERATE, RELEASE, and QUERY. If the HOLDrelay was not successful for a drawer in the LCD, the ALT306 logdescribes the error reason. When the system operates HOLD relays for allthe drawers in the LCD, the system generates an ALT306 log. The ALT306log records the results.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatALT306 mmmdd hh:mm:ss ssdd INFO ALT

Userid: userid Command: command type

Drawer Result Reason

===================================================

ssss ff b dd result text reason text

ssss ff b dd result text reason text

194 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 195: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Userid Alphanumeric Variable Identifies the userid of the grouptechnicians session that generates thelog.

Command HOLDREL Variable Identifies the command used toexecute the operation.

Drawer Numeric Variable Identifies the drawer number of theline tested.

Result Oprted.NOT OprtdRlsed,NOT Rlsed IsRlsed,Is Oprted

Variable Indicates the results of the OPERATEparameter of the HOLDRELcommand.

Indicates the results of the RELEASEparameter of the HOLDRELcommand.

Indicates the results of the QUERYparameter of the HOLDRELcommand.

Reason Symbolic text Variable Indicates the error reason, if the teston the line failed because of an error.

Active message exampleALT306 FEB04 07:14:37 2200 INFO ALT

Userid : TEAM10 Command : Holdrel

Drawer Result Reason

==================================================

HOST 00 1 0 Oprtd .

HOST 00 1 2 Oprtd .

HOST 00 1 4 Oprtd .

HOST 00 1 6 Oprtd .

HOST 00 1 8 Oprtd .

HOST 00 1 10 Oprtd .

HOST 00 1 12 Oprtd .

ALT306 195

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 196: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

HOST 00 1 14 NOT Oprtd Drawer is not equipped

HOST 00 1 16 Oprtd .

HOST 00 1 18 Oprtd .

Clear message examplen/a

Associated OM registers

ALT307The line concentrating device cutover (LCDCUT) command interpreterprogram generates the ALT307 log under the Automatic Line Testing (ALT)subsystem. The LCDCUT program cuts into service blocks of lines on lineconcentrating modules (LCM). The program cuts into service blocks bygroups of directory numbers (DN) or line equipment numbers (LEN) whencommissioning a new or expanded office. The results of the LCDCUTcommand executions are output in different logs.

Before commissioning a new switch, subscriber lines terminate on both theold and new DMS office. The program holds a cutoff (CO) relay in theoperated state for each LEN on the switch to isolate the DMS switch. Theprogram also performs automatic board-to-board testing (ABBT) to verifythe subscriber lines before cutover to the new DMS switch.

The program generates the ALT307 log when the user performs theCUTOFF or CUTOVER operation on all drawers in the LCD. The logreports the results of the execution of these commands, which the userinvokes at the LCDCUT MAP level under ALT.

This section describes the result codes and meanings.

• .... - Operation successful.

• ILCD - Invalid LCD.

• ICCD - Invalid LCDCUT card code.

• IDRN - Invalid drawer number.

• L125 - Drawer used for RSM/ESA.

• L640 - LCM limit; 125 Non-WLC lines CO relays are operated.

• DR32 - Drawer limit; 32 Non-WLC lines CO relays are operated.

• DR64 - Drawer limit; 64 CO relays are operated.

• NRSC - Failed to get resources.

196 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 197: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• LNSZ - Could not seize the line.

• NTPB - Failed to setup line telport block.

• ILNS - Invalid line state.

• ILTR - Invalid LTE result

• LWFL - Wait for LTE result failed.

• DNEQ - Drawer is not equipped.

• SRUF - SRU or SRU60 limit; 256 CO relays are operated.

• L512 - LCME limit; 512 CO relays are operated.

• NWSL - Non-WLC on SRU or LCME.

Log history

EUR003

Changed Result code S256 to SRUF for error reason

LCDCT_SRU_FULL_256. The Result code change indicates the reachingof the cutover (CO) relay threshold. The CO relay operated on all the linesin the SRU or the SRU60.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatALT307 mmmdd hh:mm:ss ssdd INFO ALT

Userid: userid Command: command type

LCD no: ssss ff Part a of b

========================================================

0 1 2 3 4 5 6 7 8 9

========================================================

nnny xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx

ALT307 197

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 198: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

nnny xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx

nnny xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx

nnny xxxx xxxx xxxx

Selected field descriptionsField Value Fixed or

VariableDescription

Userid Alphanumeric Variable Identifies the userid of the groupsession that generates the log.

Command CUTOFFCUTOVE R Variable Identifies command used to executethe operation.

LCD no Numeric Variable Identifies the number of the LCD.

Result Symbolic text Variable A four-letter code indicating the resultof the test on the line.

Active message exampleALT307 FEB04 04:31:24 4700 INFO ALT

Userid: TEAM9 Command: Cutover

LCD no: led number Part 1 of 2

===================================================

0 1 2 3 4 5 6 7 8 9

===================================================

020Y ICCD ICCD .... .... ICCD ICCD ICCD ICCD

021Y ICCD ICCD ICCD .... .... ICCD ICCD .... ICCD ICCD

022Y ICCD ICCD ICCD ICCD ICCD ICCD ICCD ICCD ICCD ICCD

023Y ICCD ICCD ICCD

Clear message examplen/a

198 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 199: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ALT308The line concentrating device cutover (LCDCUT) command interpreterprogram generates the ALT308 log under the Automatic Line Testing (ALT)subsystem. The LCDCUT program cuts into service blocks of lines on lineconcentrating modules (LCM). The LCDCUT cuts into service blocks bygroups of directory numbers (DN) or line equipment numbers whencommissioning a new or expanded office. The results of the LCDCUT areoutput in different logs.

Before commissioning a new switch, subscriber lines terminate on the oldand new DMS office. The program holds a cutoff (CO) relay in theoperated state for each LEN on the switch to isolate the DMS switch. Theprogram performs automatic board-to-board testing (ABBT) to verify thesubscriber lines before cutover to the new DMS switch.

The program generates the ALT308 log as a summary report generated atthe end of an LCDCUT session. The summary report generated at the endof an LCDCUT session is on a set of lines that a TESTID specifies. Likethe ALT309 log, execution of the CORELAY command with an action ofOPERATE or RELEASE generates the ALT308 log. The ALT308 logdiffers from the ALT309 log. The ALT308 log generates a summary insteadof a detailed log.

The following command strings generate the ALT308 log:

• CORELAY OPERATE T SUMMARY

• CORELAY RELEASE T SUMMARY

The program does not generate an ALT308 log when the program cuts adrawer off or cuts a single line.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatALT308 mmmdd hh:mm:ss ssdd INFO ALT

Userid: userid

ALT308 199

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 200: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

TESTID: testxt Order: test order

Range: LEN ssss ff b dd ll- ssss ff b dd ll

DN nnn-nnn-nnnn-nnn-nnn-nnn

PASS FAIL N/A TOTAL

nnnn nnnn nnn nnnnn

The order field specifies the cut order (By-DN or By-LEN).The range field defines the range of the lines cut. Thevalues displayed in the range field are DN or LEN. Thevalues displayed depend on the test order.

When the test order is by DN, the range column presents thelast four digits of the DNs under cut. The correspondingdigit (0-9) replaces the character "y" to get the result ofa specific line. For example, 102y represents values from1020 to 1029, depending on the value of "y." If DN performsthe cut, the range for LEN is shown as asterisks (*).

When the test order is by LEN, the range displays two digitsof the drawer number. Two digits of the line card numberfollow the two digits of the drawer number on the rangedisplay. For example, a value of 100y represents drawer 10and card 0y. "Y" can be replaced with any digit between 0and 9 to get the corresponding line card. If LEN performedthe cut, the range for DN is shown as asterisks (*).

The log displays numbers under PASS, FAIL, N/A and TOTAL.The numbers represent lines cut, lines failed, lines that donot apply, and the total number of lines defined for theTESTID.

Selected field descriptionsField Value Fixed or

VariableDescription

Userid Alphanumeric Variable Identifies the userid of the groupsession that is generating the log.

TESTID Alphanumeric Variable Identifies the TESTID name.

Order By-LENBy-DN Variable Identifies the test order.

Range: LEN Numeric Variable Identifies the line equipment number(LEN) of the line.

Range: DN Numeric Variable Identifies the directory number (DN) ofthe line.

200 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 201: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

PASS Numeric Variable Identifies the number of lines cut.

FAIL Numeric Variable Identifies the number of lines failed.

N/A Numeric Variable Identifies the number of lines notapplied to the test.

TOTAL Numeric Variable Identifies the total number of linesdefined for the TESTID.

Active message exampleALT308 FEB25 11:30:04 5764 INFO ALT

Userid: Team19

TESTID RACHER1 ORDER: By-DN

Range: LEN * * * * * * * * * * * * * *

DN 613-825-1111 - 613-825-5555

PASS FAIL N/A TOTAL

245 11 64 320

ALT308 FEB26 10:30:05 5764 INFO ALT

Userid: Team19

TESTID LCDRACHER ORDER: By-LEN

Range: LEN HOST 01 0 01 00 - HOST 01 1 01 00

DN * * * * * * * * * * * * * *

PASS FAIL N/A TOTAL

245 11 75 331

Clear message examplen/a

ALT308 201

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 202: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ALT309The line concentrating device cutover (LCDCUT) command interpreterprogram generates the ALT309 log under the Automatic Line Testing (ALT)subsystem. The program cuts into service blocks of lines on lineconcentrating modules (LCM). The program cuts into service blocks bygroups of directory numbers (DN) or line equipment numbers (LEN) whencommissioning a new or expanded office. The results of the LCDCUTcommand executions are output in different logs.

Before a new switch is omissioned, subscriber lines terminate on both theold and new DMS office. The program holds a cutoff (CO) relay in theoperated state for each LEN on the switch to isolate the DMS switch. Theprogram also performs automatic board-to-board testing (ABBT) to verifythe subscriber lines before cutover to the new DMS switch.

The ALT309 log displays a detailed status report of the cut lines that theCORELAY command executes. The log displays results for an OPERATEor RELEASE of the CO relay on each of the lines defined in a TESTID.The log displays the reasons for any errors that occurred on the lines.

The program generates the ALT309 log when the user performs theCUTOFF or CUTOVER operation on all drawers in the LCD. The logreports the results of the execution of the CUTOFF or CUTOVERcommands. The user inputs these commands at the LCDCUT MAP levelunder ALT.

The following command strings generate the ALT309 log:

• CORELAY OPERATE T FULL

• CORELAY RELEASE T FULL

The program generates the ALT309 log at the end of the cut session. Theprogram does not generate an ALT309 log when it cuts off a drawer or cutsa single line.

This section describes result codes and meanings.

• .... - Operation successful.

• ILCD - Invalid LCD.

• ICCD - Invalid LCDCUT card code.

• IDRN - Invalid drawer number.

• L125 - Drawer used for RSM/ESA.

202 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 203: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• L640 - LCM limit; 125 Non-WLC lines CO relays are operated.

• DR32 - Drawer limit; 32 Non-WLC lines CO relays are operated.

• DR64 - Drawer limit; 64 CO relays are operated.

• NRSC - Failed to get resources.

• LNSZ - Could not seize the line.

• NTPB - Failed to setup line telport block.

• ILNS - Invalid line state.

• ILTR - Invalid LTE result.

• LWFL - Wait for LTE result failed.

• DNEQ - Drawer is not equipped.

• SRUF - SRU or SRU60 limit; 256 CO relays are operated.

• L512 - LCME limit; 512 CO relays are operated.

• NWSL - Non-WLC on SRU or LCME.

Log history

EUR003

Changed Result code S256 to SRUF for error reasonLCDCT_SRU_FULL_256. The Result code change indicates the reachingof the cutover (CO) relay threshold. The CO relay operated on all the linesin the SRU or the SRU60.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatALT309 mmmdd hh:mm:ss ssdd INFO ALT

Userid: userid

TESTID: testid Order: test order

PASS FAIL N/A TOTAL

nnnn nnnn nnn nnnnn

ALT309 203

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 204: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

======================================================

Range: LEN ssss ff b dd ll - ssss ff b dd ll

DN nnn-nnn-nnnn - nnn-nnn-nnnn

======================================================

0 1 2 3 4 5 6 7 8 9

======================================================

nnny xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx

nnny xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx

nnny xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx

nnny xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx

nnny xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx

The order field specifies the cut order (By-DN or By-LEN).The range field defines the range of the lines cut. Thevalues displayed in the range field are DN or LEN. Thevalues displayed depend on the test order.

When the test order is by DN, the range column presents thelast four digits of the DNs under cut. The correspondingdigit (0-9) replaces the character "y" to get the result ofa specific line. For example, 102y represents values from1020 to 1029, depending on the value of y. If DN performsthe cut, the range for LEN is shown as asterisks (*).

When the test order is by LEN, the range displays two digitsof the drawer number. Two digits of the line card numberfollow the two digits of the drawer number on the rangedisplay. For example, a value of 100y represents drawer 10and card 0y. "Y" can be replaced with any digit between 0and 9 to get the corresponding line card. If LEN performedthe cut, the range for DN is shown as asterisks (*).

The following figure shows an ALT309 log when the test orderis by LEN.

204 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 205: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Userid Alphanumeric Variable Identifies the userid of the groupsession that generates the log.

TESTID Alphanumeric Variable Identifies the TESTID name.

Order By-LENBy-DN Variable Identifies the test order.

Range: LEN Numeric Variable Identifies the line equipment number(LEN) of the line.

Range: DN Numeric Variable Identifies the directory number (DN) ofthe line.

Result Symbolic text Variable A four-letter code indicating the resultof the test on the line.

Active message exampleALT309 AUG02 08:09:13 2300 INFO ALT

Userid: TEAM30

TESTID: LENTSTID10 Order: By-LEN

PASS FAIL N/A TOTAL part 1 of 1

7 0 16 23

====================================================

Range: LEN HOST 10 1 10 30 - HOST 19 1 11 20

DN * * * * * * * * * * * * * *

====================================================

0 1 2 3 4 5 6 7 8 9

====================================================

100Y

101Y

102Y

103Y .... ICCD

ALT309 205

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 206: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

110Y .... ICCD ICCD ICCD ICCD ICCD ICCD ICCD ICCD ICCD

111Y ICCD ICCD ICCD ICCD ICCD ICCD .... .... ....

112Y ....

113Y

Clear message examplen/a

Associated OM registers

AMA100The Automatic Message Accounting (AMA) subsystem generates AMA100when an AMA process changes status to trap or death. When an AMAprocess like AMAPROC, AMAUDITP, or AMAEI changes status, the AMAlog shows the changes. Do not suppress the AMA100 log. The AMA100log indicates the status of active billing functions in the switch.

Remedial actionThe status of each process determines the next step. Follow the directionsof the last AMA100 log received for a stream.

This section shows the status of the process and the actions to be taken.

• PREPROCESS IS DEAD - The process listed has trapped more thanfive times in five min. If the stream is not the AMA stream, anymechanism will automatically start the process. You can use theAMARESTART command to restart the stream. If it is the AMA AUDITprocess then you must pass the NIL stream to the AMARESTARTcommand.

If the stream is AMA, the AMARESTART command works. If the stream isnot AMA, the stream restarts automatically within 10 min.

• AMA: RECORDING SHUTDOWN - This only occurs with the AMADADDY process name. If any call recording is expected in the switch,this log indicates these expectations are not fulfilled. This should onlyoccur after a RESTART. If this condition occurs in an active office,contact the next level of maintenance.

• CREATE ATTEMPT FAILED - A recording stream trapped and wasrecreated successfully. If additional AMA100 logs are not received forthat process, monitor the condition.

206 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 207: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• SBA BUFFERING RECORDS - If recording to an SDM this log showsthe recording stream has died and the stream has been restarted. Thislog will be produced with a recreate count of 1 showing that the SBAapplication is accepting records to be recorded to the SDM. There willbe a total of six AMA100 logs incrementing the recreate count. The firstwill appear once the stream has been started successfully after dieing.Two more logs will appear within the next four minutes and three moreevery ten minutes for a total of six logs in thirty-four minutes.

• All Others - Another log that reports what you did to correct the eventmust follow any other status. Any other status is an intermediate status.

AttributesAttribute Value

Severity Warning

FormatAMA100 mmmdd hh:mm:ss ssdd INFO AMA PROCESS STATUS CHANGE

PROCESS NAME= aaaaa

STATUS= status

RECREATE COUNT= nnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

INFO AMAPROCESS STATUSCHANGE

Constant Fixed Indicates a process status change

PROCESS NAME Constant Fixed Identifies the status of the processor

STATUS Process, trap, ordeath

Variable

RECREATE COUNT Process, trap, ordeath

Variable Identifies the recreated number

Active message exampleAMA100 JAN02 00:22:53 6401 INFO AMA PROCESS STATUS CHANGE

PROCESS NAME= SMDR

STATUS= PROCESS

RECREATE COUNT= 1

AMA100 207

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 208: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

AMA112The Automatic Message Accounting (AMA) subsystem generates thisreport at the intervals defined in table AMAOPTS. The AMA112 log liststhe calls in progress for longer than the period defined in OFCENG. Thisreport is not generated if there are no long duration calls.

Remedial actionMaintenance personnel must make sure that the specified trunks work. Ifthe call is correct and in talking state, notify the downstream processingpersonnel and give details of the call.

AttributesAttribute Value

Severity Warning

FormatUKC21071CG AMA112 mmmdd hh:mm:ss ssdd INFO

LONG_DURATION_CALL

ORIG = clli

TERM = clli

CLG NO = dn

CLD NO = dn

CONNECT_TIME = day/hh:mm:ss REPORT COUNT = nnn

ANSWERED = Y/N

208 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 209: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFO LONGDURATION CALL

Constant Fixed Indicates that a call has been inprogress for more than the perioddefined in OFCENG.

ORIG Character string Variable The common language locationidentifier (CLLI) for the trunk group ofthe calling party.

TERM Character string Variable Gives the common language locationidentifier (CLLI) for the trunk group ofthe calling party.

CLG NO Integers Variable Gives the directory number (DN) ofthe calling party. Left justified

CLD NO Integers Variable Gives the DN of the calling party.Right justified.

CONNECT TIME Symbolic text Variable Gives the day and time when theconnection for this call was set up (asday in year/hours/minutes/seconds/milliseconds).

REPORT COUNT 0-999 Variable Gives a sequential count for eachseries of reports.

ANSWERED Y (yes), N (no) Variable Indicates whether the call wasanswered or not.

Active message exampleUKC21071CG AMA112 DEC19 12:00:03 2112 INFO LONG DURATIONCALL

ORIG = CKTKNGA201BTWBE3

TERM=LEN HOST 50 1 01 00 DN 8114005

CLG NO = 1628798004

CLD NO = 123456789123456789123456789123

CONNECT TIME = 185/11:16:47 REPORT COUNT = 324

ANSWERED = Y

Clear message examplen/a

AMA112 209

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 210: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AMA114The Automatic Message Accounting (AMA) subsystem generates reportAMA114 when an AMA rotate entry forms. The rotate entry goes into theAMA buffer, which goes into the AMA file. The count in AMA114 shouldmatch the count in the DIRP101 file rotation logs.

Remedial actionOrder up another standby AMA device.

AttributesAttribute Value

Severity Warning

FormatAMA114 mmmdd hh:mm:ss ssdd INFO FILE ROTATION ENTRY

ROTATION TYPE= rottype

STREAM NAME= stream

RECORD COUNT= reccount

CALL COUNT= recnumber

Selected field descriptionsField Value Fixed or

VariableDescription

INFO FILEROTATION ENTRY

Constant Fixed Indicates an AMA transfer

ROTATION TYPE Incoming Variable Indicates that the file rotation entry isan Incoming transfer record

Outgoing Variable Indicates that the file rotation entry isan outgoing transfer record

Outgoing-emergency Variable Indicates that the file rotation entry isan outgoing/emergency transferrecord

STREAM NAME Variable Variable Indicates the record stream set inTable CRSFMT. Examples are AMA,SMDR, and CDR.

210 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 211: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

RECORD COUNT 0-99999999 Variable Indicates the count of the eight-digitnumeric record that enters a just-closed AMA file. This count should beidentical to the count in the DIRP101,File Rotation Logs.

CALL COUNT 0-99999999 Variable Indicates the call count is an eight-digit numeric field. The field shows thenumber of records produced from callprocessing activities that generaterecords. Does not include transferrecords, time change records, orrestart indication records. AMA-114generates when file restoration occursfor recording streams found in TableCRSFMT.

Active message example*** AMA114 DEC19 12:00:00 5383 INFO FILE ROTATION ENTRY

ROTATION TYPE= OUTGOING-EMERGENCY

STREAM NAME= AMA

RECORD COUNT= 40

CALL COUNT= 40

Clear message examplen/a

Associated OM registers

AMA117The Automatic Message Accounting (AMA) subsystem generates AMA117according to the schedule that appears in table AMAOPTS. Log reportAMA117 provides the current state of the AMA options. Table AMAOPTScontrols the AMA options.

Remedial actionThere is no action required. The operating company can use this report tomake sure the AMA recording options are in the required state. To changethe states of options, the operating company can adjust the tuples in TableAMAOPTS.

AMA117 211

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 212: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatAMA117 mmmdd hh:mm:ss ssdd INFO AMA_OPTIONS

AUDIT: statxt

LOGAMA: "

LOGOPT: "

LONGCALL: "

TRACER: "

SST: "

DA411: "

CHG411: "

DA555: "

CHG555: "

UNANS: "

TRKID: "

Selected field descriptionsField Value Fixed or

VariableDescription

INFO AMA_OPTIONS Constant Fixed Indicates that the AMA option andcurrent state of the AMA option follow

AUDIT ACTIVE Variable Indicates the option is active

PENDING Variable Indicates the option is not active.Table AMAOPTS specifies the dateand time the subsystem activates theoption.

INACTIVE Variable Indicates the option is not active

LOGAMA Variable Refer to preceding AUDIT

LOGOPT Variable Refer to preceding AUDIT

212 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 213: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

LONGCALL Variable Refer to preceding AUDIT

TRACER Variable Refer to preceding AUDIT

SST Variable Refer to preceding AUDIT

DA411 Variable Refer to preceding AUDIT

CHG411 Variable Refer to preceding AUDIT

DA555 Variable Refer to preceding AUDIT

CHG555 Variable Refer to preceding AUDIT

UNANS Variable Refer to preceding AUDIT

TRKID Variable Refer to preceding AUDIT

Active message exampleAMA117 JUL14 23:56:00 4721 INFO AMA_OPTIONS

AUDIT: PENDING

LOGAMA: ACTIVE

LOGOPT: ACTIVE

LONGCALL: PENDING

TRACER: ACTIVE

SST: ACTIVE

DA411: INACTIVE

CHG411: INACTIVE

DA555: INACTIVE

CHG555: INACTIVE

UNANS: ACTIVE

TRKID: INACTIVE

Clear message examplen/a

AMA117 213

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 214: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AMA118The Automatic Message Accounting (AMA) subsystem generates AMA118to indicate the status of AMA options. Set option LOGOPT in tableAMAOPTS to control the generation the AMA118 log. The user can setLOGOPT so that the system does not generate the AMA118 log. The usercan set the LOGOPT so that the system generates the AMA118 log every24 h, or at chosen intervals. When LOGOPT is in the default configuration,the system does not generate this log report.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAMA118 mmmdd hh:mm:ss ssdd INFO AMA OPTIONS

AmaOption: Status

Selected field descriptionsField Value Fixed or

VariableDescription

INFO AMA_OPTIONS Constant Fixed Indicates a report of status of optionsin Table AMAOPTS.

AmaOption Variable Identifies the option in TableAMAOPTS. Refer to the data schemasection of the Translations Guide for acomplete description of each of theoptions in Table AMAOPTS.

Status ACTIVE Variable Indicates activation of the option inTable AMAOPTS.

INACTIVE Variable Indicates deactivation of the option inTable AMAOPTS.

PENDING Variable Indicates the option scheduled inTable AMAOPTS not activated.

Active message exampleAMA118 APR13 12:00:00 0615 INFO AMA_OPTIONS

214 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 215: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

ACBAR_MOD_CO: INACTIVE

ACBAR_STY_IN: INACTIVE

APPEND_ISDN_CKT_ID: ACTIVE

AUDIT: ACTIVE

BCLID_USPAUD: ACTIVE

BCLONGCALL: ACTIVE

CALL_FWD: ACTIVE

CALL_TIMECHG: INACTIVE

CCSADATA INACTIVE

CDAR: INACTIVE

CDRDUMP: INACTIVE

CDRLONGCALL: INACTIVE

CDARSYNC: INACTIVE

CHG411: INACTIVE

CHG555: ACTIVE

CIDSUSPAUD: ACTIVE

CITYWIDE: INACTIVE

CMCICWK: INACTIVE

CMCORIG: INACTIVE

CMCTERM: INACTIVE

AMA118 APR13 12:00:00 0615 INFO AMA_OPTIONS

CMCTERM: INACTIVE

COIN: ACTIVE

CRSEQNUM: INACTIVE

AMA118 215

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 216: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

CSMI: ACTIVE

DA411: ACTIVE

DA555: ACTIVE

DSCWID_CONF_AUDIT: ACTIVE

ENFIA_B_C: ACTIVE

FREECALL: INACTIVE

FTRCODE: INACTIVE

HIGHREV: INACTIVE

INTRASITE: INACTIVE

INTRASITE: INACTIVE

INWATS: ACTIVE

ISDNCIRCUIT: INACTIVE

LOGAMA: ACTIVE

LOGOPT: ACTIVE

LOGTEST: INACTIVE

LONGCALL: ACTIVE

LUSORIG: ACTIVE

LUSTERM: ACTIVE

OBSERVED: ACTIVE

OCCTERM: ACTIVE

OUTWATS: ACTIVE

OCCOVFL: ACTIVE

OVERFLOW: INACTIVE

SAID_MOD_SUPPR: ACTIVE

216 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 217: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

SUSP: INACTIVE

TIMECHANGE: ACTIVE

TRACER: INACTIVE

TWC: ACTIVE

U3WC: ACTIVE

UNANS_AIN: INACTIVE

UNANS_LOCAL: ACTIVE

UNANS_TOLL: ACTIVE

UNANS_TOPS: ACTIVE

Clear message examplen/a

Associated OM registers

AMAB100The Automatic Message Accounting Buffer (AMAB) subsystem generatesreport AMAB100 to indicate an AMA call entry. The report appears if theoffice parameter SPECIAL_AMA_REPORT is set to ON in the officeparameter tables. To avoid too many output reports, request a report onlyduring periods of low traffic.

The following describes call event information (digit 1):

• Digit 1 value - 0 -- Service observed - No -- Charged - No -- Trafficsampled - No

• Digit 1 value - 1 -- Service observed - Yes -- Charged - No -- Trafficsampled - No

• Digit 1 value - 2 -- Service observed - No -- Charged - Yes -- Trafficsampled - No

• Digit 1 value - 3 -- Service observed - Yes -- Charged - Yes -- Trafficsampled - No

• Digit 1 value - 4 -- Service observed - No -- Charged - No -- Trafficsampled - Yes

• Digit 1 value - 5 -- Service observed - Yes -- Charged - No -- Trafficsampled - Yes

AMAB100 217

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 218: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• Digit 1 value - 6 -- Service observed - No -- Charged - Yes -- Trafficsampled - Yes

• Digit 1 value - 7 -- Service observed - Yes -- Charged - Yes -- Trafficsampled - Yes

The following describes call event information (digit 2):

• Digit 2 value - 0 - ANI fail - No - Operator dialed - No - Operatoridentified - No

• Digit 2 value - 1 - ANI fail - Yes - Operator dialed - No - Operatoridentified - No

• Digit 2 value - 2 - ANI fail - No - Operator dialed - Yes - Operatoridentified - No

• Digit 2 value - 3 - ANI fail - Yes - Operator dialed - Yes - Operatoridentified - No

• Digit 2 value - 4 - ANI fail - No - Operator dialed - No - Operatoridentified - Yes

• Digit 2 value - 5 - ANI fail - Yes - Operator dialed - No - Operatoridentified - Yes

• Digit 2 value - 6 - ANI fail - No - Operator dialed - Yes - Operatoridentified - Yes

• Digit 2 value - 7 - ANI fail - Yes - Operator dialed - Yes - Operatoridentified - Yes

The following describes service features (digits 1 and 2):

• Service feature code - 0 -- Service feature - Indicates default, or non-coin telephone.

• Service feature code - 1 -- Service feature - Indicates a coin telephone

• Service feature code - 2 -- Service feature - Indicates a hotel or moteltelephone line.

• Service feature code - 3 -- Service feature - Indicates a picture phone.

• Service feature code - 4 -- Service feature - Indicates a Dataphone 50.

• Service feature code - 5 -- Service feature - Indicates a three-way, add-on service.

• Service feature code - 6 -- Service feature - Indicates a conference call.

• Service feature code - 7 -- Service feature - Indicates call forwarding.

218 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 219: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The following describes events during call:

• Value - 0 -- Answer - Yes -- Calling party disconnect - Yes -- Calledparty disconnect - No -- Blue

• box fraud - No -- Blocked - No

• Value - 1 -- Answer - Yes -- Calling party disconnect - No -- Calledparty disconnect - Yes -- Blue

• box fraud - No -- Blocked - No

• Value - 2 -- Answer - No -- Calling party disconnect - Yes -- Calledparty disconnect - No -- Blue

• box fraud - No -- Blocked - No

• Value - 3 -- Answer - No -- Calling party disconnect - No -- Called partydisconnect - Yes -- Blue

• box fraud - No -- Blocked - No

• Value - 4 -- Answer - Yes -- Calling party disconnect - Yes -- Calledparty disconnect - No -- Blue

• box fraud - Yes -- Blocked - No

• Value - 5 -- Answer - Yes -- Calling party disconnect - No -- Calledparty disconnect - Yes -- Blue

• box fraud - Yes -- Blocked - No

• Value - 6 -- Answer - No -- Calling party disconnect - Yes -- Calledparty disconnect - No -- Blue

• box fraud - Yes -- Blocked - No

• Value - 7 -- Answer - No -- Calling party disconnect - No -- Called partydisconnect - Yes -- Blue

• box fraud - Yes -- Blocked - No

• Value - 8 -- Answer - No -- Calling party disconnect - Yes -- Calledparty disconnect - No -- Blue

• box fraud - No -- Blocked - Yes

Remedial actionn/a

AttributesAttribute Value

Severity Warning

AMAB100 219

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 220: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FormatAMAB100 mmmdd hh:mm:ss ssdd INFO AMA_CALL_DATA

an nn nn nn dn dn n day hh mm ss nnnnnn

ORIG=trkid TERM=trkid ANS=txt

Selected field descriptionsField Value Fixed or

VariableDescription

INFOAMA_CALL_DATA

Constant Fixed Indicates that this report containsAMA call data.

an (B,F), (0-8) Variable Gives the record code that identifiesthe call type the system records.

nn 00-99 Variable Gives the entry code that identifies thecall type the system records. Refer toExplanation.

nn (0-7), (0-7) Variable Gives call event information. Digit 1 isleft. Refer to Explanation.

nn (0-7), (0-7) Variable Indicates the service features ofcalling and called parties. Digit 1represents calling AMAB100 partyservice features. Digit 2 representscalled party service features. Refer toExplanation.

dn Symbolic text Variable Identifies the calling number. Refer toExplanation.

n 0-8 Variable Provides information about eventsduring the call. Refer to Explanation.

day 1-366 Variable Indicates the day of the year of theAMA call entry.

hh mm ss Variable Indicates the time of the AMA callentry.

0-23 Variable Indicates hours

0-59 Variable Indicates minutes

0-59 Variable Indicates seconds

nnnnnn 000000-999999 Variable Gives the conversation time inseconds.

ORIG=trkid Symbolic text Variable Identifies the origination point of thecall. Refer to Explanation.

TERM=trkid Symbolic text Variable Identifies the termination point of thecall. Refer to Explanation.

220 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 221: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ANS=txt Y Variable Indicates that the called partyanswered.

N Variable Indicates that the called party did notanswer.

Active message exampleAMAB100 MAY28 15:41:00 7325 INFO AMA_CALL_DATA

B4 00 20 00 6138651004 6138652090 0 149 15 40 56 000003

ORIG=CKT M613ICAMA 0 TERM=CKT M613INTERTOLL 0 ANS=Y

Clear message examplen/a

Associated OM registers

AMAB101The Automatic Message Accounting Buffer (AMAB) subsystem generatesreport AMAB101 after a LAMA call entry. The report appears if the officeparameter SPECIAL_AMA_REPORT is set to ON in the office parametertables. This log contains the billing details of a local-to-toll call. To avoidtoo many output reports, request the report only during periods of lowtraffic.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAMAB101 mmmdd hh:mm:ss ssdd INFO LAMA_CALL_DATA

an nn nn nn dn dn n day hh mm ss nnnnnn

ORIG=len dn TERM=trkid ANS=txt DDO=txt

AMAB101 221

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 222: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFOLAMA_CALL_DATA

Constant Fixed Indicates that this report containsLAMA call data.

an (B,F), (0-8) Variable Gives the record code that identifiesthe call type the system records.

nn 00-99 Variable Gives the entry code that identifies thecall type the system records. SeeTable I.

nn (0-7), (0-7) Variable Indicates call event information. Digit1 remains. Refer to the call eventinformation tables in log reportAMAB100.

nn (0-7), (0-7) Variable Indicates the service features of thecalling and called parties. Digit 1represents the calling party servicefeature. Digit 2 represents called partyservice features. Refer to the servicefeatures table in log report AMAB100.

dn Symbolic text Variable Identifies the calling number. SeeTable I.

dn Symbolic text Variable Identifies the called number. SeeTable I.

n (0-8) Variable Provides information about eventsduring the call. Refer to the TableEvents during call in log reportAMAB100.

day 1-366 Variable Gives the day of the year of a LAMAcall entry.

hhmmss Variable Indicates the time of the day of aLAMA call entry.

0-23 Variable Indicates hours

0-59 Variable Indicates minutes

0-59 Variable Indicates seconds

nnnnnn 000000-999999 Variable Gives the conversation time inseconds.

ORIG=len dn Symbolic text Variable Identifies the origination point of callgiving line equipment number,including site identifier, if used. SeeTable I.

TERM=trkid Symbolic text Variable Identifies the termination point of call.See Table I.

222 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 223: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ANS=txt Y Variable Indicates that the called partyanswered.

N Variable Indicates that the called party did notanswer.

DDO=txt Y Variable Indicates that the call was directdialed overseas.

N Variable Indicates that the call was not directdialed overseas.

Active message exampleAMAB101 MAY28 15:41:00 7325 INFO LAMA_CALL_DATA

B4 00 20 00 6138651004 6138652090 0 149 15 40 56 000003

ORIG=CKT M613ICAMA 0 TERM=CKT M613INTERTOLL O ANS=Y

DDO=N

Clear message examplen/a

Associated OM registers

AMAB102The Automatic Message Accounting Buffer (AMAB) subsystem generatesreport AMAB102 for each AMA call entry. To receive this report, set officeparameter SPECIAL_AMA_REPORT to ON in the office parameter tables.To avoid too many output reports, request this report only during periods oflow traffic.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAMAB102 mmmdd hh:mm:ss ddss INFO TOPS_F_ENTRY

Fn nn nn nn dn dn n day hhmmss nnnnnn nnnn nn nnnn nn

AMAB102 223

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 224: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

ORIG = trkid TERM = trkid ANS = txt

Selected field descriptionsField Value Fixed or

VariableDescription

NNNNYYYY Variable Validity Check Failure or Security?See Note 4.

Variable Digit 2

NYNYNYNY Variable Trouble Report?

NNYYNNYY Variable Charge Adjust?

NNNNYYYY Variable Local Call?

Variable Digit 3

N Y N Y N Y ** Variable Dial Rate Key?

N N Y Y N N ** Variable Automatic No AMA?

N N N N Y Y ** Variable Ao AMA Key?

Variable Digit 4

NYNYNYNY Variable Call Transfer?

NNYYNNYY Variable Cancel Timing?

NNNNYYYY Variable Cancel Call?

nn 00-99 Variable TOPS call originating type. A 2 digitcode indicating how a call originatedto a TOPS operator.

00 Variable Not Used

01 Variable 1+(011+)

02 Variable 0+(01+)

03 Variable

06 Variable INTC

07 Variable 1153 (marine)

08 Variable 141 (rate and route)

09 Variable MOBILE

10 Variable 121

11-19 Variable Reserved for future use.

04 Variable RONI

05 Variable ALM

20 Variable 131

21-29 Variable Reserved for future use.

30 Variable 181

224 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 225: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

31-39 Variable Reserved for future use.

40 Variable 1150

41 Variable Reserved for future use.

42 Variable 1152 (Mobile)

43-49 Variable Reserved for future use.

50 Variable 1155

51-59 Variable Reserved for future use.

60 Variable 1156

61 Variable Reserved for future use.

62 Variable 1158

63 Variable 1159

64-69 Variable Reserved for future use.

70 Variable Indicates delay calls

71-79 Variable Reserved for future use.

80 Variable Coin Recalls

81-88 Variable Reserved for future use.

89 Variable 411

90 Variable 555 (universal information)

91-99 Variable Reserved for future use.

ORIG = trkid Symbolic text Variable Originating point of call identifier. SeeTable I.

TERM = trkid Symbolic text Variable Termination point of call identifier. SeeTable I.

ANS = txt Y Variable Indicates that the called partyanswered.

N Variable Indicates that the called party did notanswer.

INFOTOPS_F_ENTRY

CONSTANT Variable Indicates that this report containsTOPS entry call data.

Fn Variable Indicates format number.

F0 Variable Indicates domestic 1+.

F1 Variable Indicates domestic TOPS.

F2 Variable Indicates overseas 1+.

F3 Variable Indicates overseas TOPS.

AMAB102 225

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 226: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

nn 00-99 Variable Gives the entry code, which identifiesthe call type the system records. SeeTable R.

nn (0-7), (0-7) Variable Gives Call Event Information. Digit 1 isleft. Refer to Table Call eventinformation in log report AMAB100.

nn (0-7), (0-7) Variable Indicates the service features ofcalling and called parties. Digit 1represents the calling party servicefeatures. Digit 2 represents calledparty service features. Refer to TableService features in log reportAMAB100.

dn Symbolic text Variable Gives the calling number. See Table I.

dn Symbolic text Variable Gives the called number. See Table I.

n 0-8 Variable Provides information about eventsduring the call. Refer to Table Eventsduring call in log report AMAB100.

nnn 1-366 Variable Indicates the day of the year of anAMA call entry.

hhmmss Variable Indicates the time of an AMA callentry.

0-23 Variable Indicates hours.

0-59 Variable Indicates minutes.

0-59 Variable Indicates seconds.

nnnnnn 000000-999999 Variable Gives the conversation time inseconds.

nnnn 0000-9999 Variable Defines the assigned number of theTOPS operator handling the call. SeeNote 1.

nn 00-99 Variable Defines the team to which the systemassigns the TOPS operator.

nnnn 0000-9999 Variable TOPS information digits. Note 1.

nn 0-7 Variable TOPS call origination. Note 1.

01234567 Variable Digit 1

NYNYNYNY Variable No Connect?

NNYYNNYY Variable Verification Request?

226 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 227: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleAMAB102 JUL04 16:33:06 6088 INFO TOPS_F_ENTRY

F1 22 20 00 61369 24681 2 5146 231111 000020 0099 09 0000

02

ORIG = CKT TOPCOMAMF TERM = CKT TERMBX01 ANS = Y

Clear message examplen/a

Associated OM registers

AMAB103The Automatic Message Accounting Buffer (AMAB) subsystem generatesreport AMAB103 for each AMA call entry. To receive this report, set officeparameter SPECIAL_AMA_REPORT to ON in the office parameter tables.To avoid too many output reports, request this report only during periods oflow traffic.

The AMAB103 report follows an AMAB102 report.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAMAB103 mmmdd hh:mm:ss ssdd INFO TOPS_E0_ENTRY

n nnn...AAA...A

Selected field descriptionsField Value Fixed or

VariableDescription

INFOTOPS_E0_ENTRY

Constant Fixed Indicates that the report contains datafor TOPS extension record code EO(special billing).

n Variable Identifies the special billing numbertype.

AMAB103 227

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 228: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Variable DMS-200 TOPS

0 Variable Domestic third number

1 Variable Domestic credit card

2 Variable Overseas third number

3 Variable Overseas credit card

Variable DMS-250 TOPS

0 Variable Unassigned

1 Variable Calling card billing

2 Variable Unassigned

3 Variable A250 ANI billing

nnn...AAA...A max of 19 characters Variable Identifies the number to which thesystem bills the call. The billingnumbers align to the left and containas fillers. See Automatic MessageAccounting Northern TelecomFormat , 297-1001-119, for values anddescriptions.

Active message exampleAMAB103 JUL04 16:33:06 6089 INFO TOPS_E0_ENTRY

0 6138412222*********

Clear message examplen/a

Associated OM registers

AMAB104The Automatic Message Accounting Buffer (AMAB) subsystem generatesreport AMAB104 for each AMA call entry. To receive the report, set officeparameter SPECIAL_AMA_REPORT to ON in the office parameter tables.To avoid too many output reports, only request this report during periods oflow traffic.

The AMAB104 report follows a AMAB102 report.

Remedial actionn/a

228 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 229: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatAMAB104 mmmdd hh:mm:ss ssdd INFO TOPS_E1_ENTRY

hhhhhh hhhhhhhh

Selected field descriptionsField Value Fixed or

VariableDescription

INFOTOPS_E1_ENTRY

Constant Fixed Indicates that the report contains datafor TOPS extension record code E1(hotel).

hhhhhh Six Hexadecimal Variable Hotel room number can be six digits,three alphas or a collection. SeeAutomatic Message AccountingNorthern Telecom Format ,297-1001-119.

hhhhhhhh Four alphas, eachrepresented by 2hexadecimals

Variable Identifies hotel guest name

Active message exampleAMAB104 JUL04 16:33:06 6390 INFO TOPS_E1_ENTRY

123456 C7D2D5C4

Clear message examplen/a

Associated OM registers

AMAB105The Automatic Message Accounting Buffer (AMAB) subsystem generatesreport AMAB105 for each time AMA call entry. To receive the report, setoffice parameter SPECIAL_AMA_REPORT to ON in the office parametertables. To avoid too many output reports, request this report only duringperiods of low traffic.

This report follows an AMAB102 report.

AMAB105 229

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 230: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionAction not required. Telco can use this report to verify routing systemtranslation.

AttributesAttribute Value

Severity Warning

FormatAMAB105 mmmdd hh:mm:ss ssdd INFO TOPS_E2_ENTRY

nnnnn nnnnn n h

Selected field descriptionsField Value Fixed or

VariableDescription

INFOTOPS_E2_ENTRY

Constant Fixed Indicates that the report contains dataassociated with TOPS extensionrecord code E2 (CHARGE).

nnnnn 00000-99999 Variable Indicates hotel tax or coin amount incents.

nnnnn 00000-99999 Variable Indicates amount for hotel call, orquoted amount in cents if call is timeand charge.

n 0-9 Variable Indicates number of coin overtimerecalls to position.

h 0-f Variable Indicates filler character to fill ourrecord to the required number ofdigits.

Active message exampleAMAB105 JUL04 16:33:06 6391 INFO TOPS_E2_ENTRY

00350 00350 3 012

Clear message examplen/a

230 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 231: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AMAB106The Automatic Message Accounting Buffer (AMAB) subsystem generatesreport AMAB106 for each AMA call entry. To receive this report, set officeparameter SPECIAL_AMA_REPORT to ON in the office parameter tables.To avoid too many output reports, request this report only during periods oflow traffic.

The AMAB106 report follows an AMAB102 report.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAMAB106 mmmdd hh:mm:ss ssdd INFO TOPS_E4_ENTRY

hhmm n nn n nnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

INFOTOPS_E4_ENTRY

Constant Fixed Indicates that the report contains datafor TOPS extension record E4 (chargeadjustment).

nnnn Variable Indicates the approximate time of thecall that requires the adjustment.

0-23 Variable Indicates hours.

0-59 Variable Indicates minutes.

n Variable Gives the reason for chargeadjustment.

0 Variable Indicates wrong number.

1 Variable Cancel previous charge adjust.

2 Variable Poor transmission.

3 Variable Indicates empty.

4 Variable Indicates empty.

5 Variable Indicates cut off.

AMAB106 231

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 232: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

6 Variable Indicates manually rated.

7 Variable Indicates change billing.

8 Variable Indicates coin under collect.

9 Variable Indicates coin over collect.

nn 00-99 Variable Gives charge adjustment entry code.This adjustment will be identical to theentry code in the first billing recordwhen a change in billing occurs. SeeTable I.

n Variable Gives the charge adjustment indicator,a single digit that indicates how creditwill be applied.

0 Variable Indicates the system did not providean indicator.

1 Variable Indicates minutes the system willcredit.

2 Variable Indicates dollars and cents the systemwill credit.

3 Variable Indicates whole call the system willcredit.

nnnnn Variable Gives the charge adjustment amount.

00001-65536 Variable Indicates amount in cents

OOAAA-99AAA Variable Indicates amount in minutes, as arefiller characters.

Active message exampleAMAB106 JUL04 16:33:06 6492 INFO TOPS_E4_ENTRY

0824 6 22 1 00240

Clear message examplen/a

Associated OM registers

AMAB108The Automatic Message Accounting Buffer (AMAB) subsystem generatesreport AMAB108 by the auxiliary operator service system (AOSS) chargeformater. The report appears when a AOSS call that can be recordedends.

232 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 233: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

This section shows the charge details, digit 1 values and its explanations.

• 0 - Indicates the call cam be charged and manual "no charge" overridedid not occur.

• 1 - Indicates the call cannot be charged and manual "no charge"override did not occur.

• 2 - Indicates the call can be charged and manual "no charge" overrideoccurred.

• 3 - Indicates the call cannot be charged and manual "no charge"override occurred.

• 4 - Indicates the call can be charged. The subscriber disconnectedbefore connection to an Audio Response Unit.

• 5 - Indicates the call cannot be charged. The subscriber disconnectedbefore connection to an Audio Response Unit.

This section shows the transfer and trouble details, digit 2 values and itsexplanations.

• 0 - Indicates the system did not transfer the call and did not report anyproblems.

• 1 - Indicates a transferred call.

• 2 - Indicates a call with a problem reported.

• 3 - Indicates the system transferred a call with a problem recorded.

This section shows the origination type code and the call origination type.

• 00 - Unspecified.

• 01 - Indicates a local directory assistance call when subscriber dialed411.

• 02 - Indicates a HNPA DA call when the subscriber dialed 1+555-1212.

• 03 - Indicates a FNPA DA call when subscriber dialed I+NPA+555-1212.

• 04 - Indicates a traffic operator dialed 131 to ask for assistance from anAOSS operator.

• 05 - Indicates a traffic operator dialed 141 to obtain rate and routeinformation from an AOSS operator.

• 06 - Indicates a call intercepted by an AOSS operator.

• 07 - Indicates an ACS keyed by operator to access a forward number.

Remedial actionn/a

AMAB108 233

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 234: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatAMAB108 mmmdd hh:mm:ss ssdd INFO AOSS_F8_ENTRY

F8 ec ce sf dn fwddn day hhmmss oprn tn ct co n chd

Selected field descriptionsField Value Fixed or

VariableDescription

INFOAOSS_F8_ENTRY

Constant Fixed Indicates a report of data associatedwith the AOSS.

F8 Constant Fixed Identifies an AOSS record type.

ec 00-99 Variable Identifies the entry code. See Table R.

ce (0-7), (0-7) Variable Indicates call event Information. Digitone is on the left. Refer to Table callevent information in log reportAMAB100.

sf (0-7), (0-7) Variable Indicates service features of callingparty (left digit) and the forward party(right digit). Refer to the Table Servicefeatures in log report AMAB100.

dn Symbolic text Variable Identifies calling number. See Table I.

fwddn 2-10 digits Variable Identifies the forward number theoperator enters.

day 1-366 Variable Indicates the day of the year on whichthe call arrived at the AOSS position.

hhmmss 000000-235959 Variable Indicates the time of the day when thecall arrived at the AOSS position.

oprn 0000-9999 Variable Identifies AOSS operator that handlesthe call.

tn 00-99 Variable Identifies the team the system assignsto the AOSS operator.

ct (0-5)(0-3) Variable Provides charge, transfer, and troubleinformation concerning the AOSS thesystem handles. Digit 1 (left)represents charge details. Refer toTable Charge details at the end of thislog report. Digit 2 represents transfer

234 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 235: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

and trouble details. Refer to TableTransfer and trouble details at the endof this log report.

co 00-07 Variable Indicates origination method of a callto an AOSS operator. Refer to TableCall Origination Type at the end of thislog report.

n 0 Variable Indicates the call is not a recall or acut through.

1 Variable Indicates the system recalls call to theoperator.

2 Variable Indicates the call cuts through to theoperator.

chd 0-255 Variable Indicates downstream chargedetermination.

Active message exampleAMAB108 NOV14 22:50:43 9316 INFO AOSS_F8_ENTRY

F8 00 24 00 61322123 617777 003 094032 0212 02 00 01 1

057

Clear message examplen/a

Associated OM registers

AMAB109The Automatic Message Accounting Buffer (AMAB) subsystem generatesreport AMAB109. The report provides the automatic message accountingdata associated with the call.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

AMAB109 235

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 236: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FormatAMAB109 mmmdd hh:mm:ss ssdd INFO TOPS_OOC_B2_ENTRY

dn ******** ******* dn

altrtxt nnn

clgnm

cldnm

Selected field descriptionsField Value Fixed or

VariableDescription

INFOTOPS_OOC_B2_ENTRY

Constant Fixed Indicates that this call provides datarelated to an overseas call the systemplaces through an operator.

dn Symbolic text Variable Indicates calling number. Refer toTable I.

dn Symbolic text Variable Indicates called number. Refer toStandard definitions and equipmentidentification table.

altrtxt Variable Indicates alternate route.

clgnm 00-FF (x20) Variable Calling name, the operator enters andtranslates into hexadecimal. Refer toAutomatic Message AccountingNorthern Telecom Format ,297-1001-119 for details on thestructure of AMAB log reports.

cldnm 00-FF (x20) Variable Called name, the operator enters andtranslates into hexadecimal. Refer toAutomatic Message AccountingNorthern Telecom Format ,297-1001-119 for details on thestructure of AMAB log reports.

Active message exampleAMAB109 MAY28 02:24:44 2001 INFO TOPS_OOC_B2_ENTRY

B2 97 20 00 6135421263 ********* ******* 2 071 022435 00

0022 0211 02 0000 03 000

C3c3c3c5d6d9d0aac5c5c7c8c9c4c3c9c3c3c3c5

236 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 237: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

C3c3c3c5d6d9d0aac5c5c7c8c9c4c3c9c3c3c3c5

Clear message examplen/a

Associated OM registers

AMAB110The Automatic Message Accounting Buffer (AMAB) subsystemTOPS_E5_ENTRY is the charge adjust extension record for the record thepreceding AMAB109 log reports.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAMAB110 mmmdd hh:mm:ss ssdd INFO TOPS_E5_ENTRY

chrgtxt

Selected field descriptionsField Value Fixed or

VariableDescription

INFOTOPS_E5_ENTRY

Constant Fixed Provides the charge adjust extensionrecord for the record the precedingAMAB109 log reports.

chrgtxt Alphanumeric Variable Charge adjust type field. Refer toAutomatic Message AccountingNorthern Telecom Format ,297-1001-119 for a completeexplanation of this field.

Active message exampleAMAB110 MAY28 03:35:44 2002 INFO TOPS_E5_ENTRY

E5 03 34 02 63 1 00155 0

Clear message examplen/a

AMAB110 237

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 238: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AMAB111The Automatic Message Accounting Buffer (AMAB) subsystem generatesthis report AMAB111. The report provides automatic message accountinginformation for an enhanced 800 service call.

Remedial actionAction not required. This log is for information and for testing.

AttributesAttribute Value

Severity Warning

FormatAMAB111 mmmdd hh:mm:ss ssdd INFO TOPS_B6_B7_ENTRY

recod entcod infdig serv clgdn clddn evinfo day hhmmss ctime

opnum tmnum infodig orig ooz rao 800dn

Selected field descriptionsField Value Fixed or

VariableDescription

90 Variable 555 (universal information)

91-99 Variable Reserved for future use.

ooz 1 Variable Indicates that a customer withenhanced 800 service agrees toaccept 800 calls to the 800 number.These calls are from outside the zonefor which the customer purchased the800 service.

0 Variable Indicates that a customer withenhanced 800 service has not agreedto accept calls to the 800 number fromoutside the zone for which thecustomer has purchased the 800service.

RAO 000-999 Variable Identifies the revenue accountingoffice that services the 800 number.

800dn Refer to the definitionof dn in Table I.

Variable Identifies the directory number of theenhanced 800 service subscriberinvolved.

238 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 239: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

INFOTOPS_B6_B7_ENTRY

Constant Fixed Indicates a report of domestic (B6) orinternational (B7) enhanced 800service AMAB.

Recod B6 Variable Provides the record code (B6) of theAMAB if the called number isdomestic.

B7 Variable Provides the record code (B7) of theAMAB if the called number isInternational.

entcod 00-99 Variable Provides the entry code, whichidentifies the call type the systemrecords. Refer to Table R.

infdig 00-77 Variable Provides call event information. Digitone remains. Refer to Table Callevent information at the end of logreport AMAB100.

serv 00-77 Variable Indicates the service features of thecalling and called parties. Digit 1represents calling party servicefeatures. Digit 2 represents calledparty service features. Refer to theTable Service features at the end oflog report AMAB100.

clgdn dn Variable Identifies the calling number. Refer toTable I.

clddn dn Variable Identifies the called number. Refer toTable I.

day 0 - 366 Variable Indicates the day of the year on whichthe call was made.

ctime 000000-999999 Variable Provides the conversation time inseconds.

opn 0000 - 9999 Variable Identifies the assigned number of theTOPS operator handling the call.

tmn 00 - 99 Variable Identifies the team the system assignsto the TOPS operator.

infodig Each of the four digitshas a value of 0 - 7.

Variable Provides additional TOPS information.Digit 1 is the last left digit.

Digit 1 0 1 2 3 4 5 6 7 Variable Digit 1

N Y N Y N Y N Y Variable No Connect?

N N Y Y N N Y Y Variable Verification Request?

N N N N Y Y Y Y Variable Validity Check Failure or Security?

AMAB111 239

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 240: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Digit 2 0 1 2 3 4 5 6 7 Variable Digit 2

N Y N Y N Y N Y Variable Trouble Report?

N N Y Y N N Y Y Variable Charge Adjust?

N N N N Y Y Y Y Variable Local Call?

Digit 3 0 1 2 3 4 5 6 7 Variable Digit 3

N Y N Y N Y N Y Variable Dial Rate Key?

N N Y Y N N Y Y Variable Automatic No AMA?

N N N N Y Y Y Y Variable Ao AMA Key?

Digit 4 0 1 2 3 4 5 6 7 Variable Digit 4

N Y N Y N Y N Y Variable Call Transfer?

N N Y Y N N Y Y Variable Cancel Timing?

N N N N Y Y Y Y Variable Cancel Call?

01 Variable 1+ (011+)

02 Variable 0+ (01+)

03 Variable

04 Variable RONI

05 Variable ALM

06 Variable INTC

orig 00 - 99 Variable Indicates TOPS call originating type. A2-digit code indicates how a calloriginates to a TOPS operator.

00 Variable Not Used

07 Variable 1153 (marine)

08 Variable 141 (rate and route)

09 Variable MOBILE

10 Variable 121

11-19 Variable Reserved for future use.

20 Variable 131

21-29 Variable Reserved for future use.

30 Variable 181

31-39 Variable Reserved for future use.

40 Variable 1150

41 Variable Reserved for future use.

42 Variable 1152 (Mobile)

240 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 241: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

43-49 Variable Reserved for future use.

50 Variable 1155

51-59 Variable Reserved for future use.

60 Variable 1156

61 Variable Reserved for future use.

62 Variable 1158

63 Variable 1159

64-69 Variable Reserved for future use.

70 Variable Indicates delay calls.

71-79 Variable Reserved for future use.

80 Variable Indicates coin recalls.

81-88 Variable Reserved for future use.

89 Variable 411

Active message exampleAMAB111 Jul10 03:10:44 2001 INFO TOPS_B6_B7_ENTRY

B6 97 20 00 6135421263 2122201234***** 2 071 022435

000022

0211 02 0000 03 0 662 8004654329

Clear message examplen/a

Associated OM registers

AMAB115The Automatic Message Accounting Buffer (AMAB) subsystem generatesthis report AMAB115. The report indicates an identification failure when anORIG terminal creates a Station Message Detail Recording (SMDR) recordfor a call.

AMAB115 241

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 242: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionThis report indicates two possible conditions. The special billing number forstation ORIG has less than seven digits. If ORIG is an attendant console,the customer group billing number has less than seven digits. If ORIG is atrunk, check the billing number in the trunk group. If ORIG is not a trunk,report the problem to your maintenance support group.

AttributesAttribute Value

Severity Indeterminate

FormatAMAB151 mmmdd hh:mm:ss ssdd FAIL SMDR_ANI_FAIL

ORIG LEN len DN dn

Selected field descriptionsField Value Fixed or

VariableDescription

FAILSMDR_ANI_FAIL

Constant Fixed Indicates an automatic numberidentification (ANI) failure duringcreation of an SMDR record

ORIG LEN Integers Variable Identifies the line equipment.

DN Integers Variable Gives the calling number.

Active message exampleAMAB151 SEP16 10:55:13 3932 FAIL SMDR_ANI_FAIL

ORIG LEN HOST 00 1 05 03 DN nnnnnnn

Clear message examplen/a

Associated OM registers

AMAB118The Automatic Message Accounting Buffer (AMAB) subsystem generatesthis report by the Auxiliary Operator Service System (AOSS) chargeformatter. The report appears when a recordable AOSS voice response(VR) call ends.

242 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 243: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

This section shows the charge details, digit 1 values and its explanations.

• 0 - Indicates the call is chargeable and manual "no charge" override didnot occur.

• 1 - Indicates the call is not chargeable and manual "no charge" overridedid not occur.

• 2 - Indicates the call is chargeable and manual "no charge" overrideoccurred.

• 3 - Indicates the call is not chargeable and manual "no charge" overrideoccurred.

• 4 - Indicates that the call is chargeable but the subscriber disconnectedbefore connection to an Audio Response Unit.

• 5 - Indicates the call is not chargeable but the subscriber disconnectedbefore connection to an Audio Response Unit.

This section shows the transfer and trouble details, digit 2 values and itsexplanations.

• 0 - Indicates the call did not transfer and a problem reported.

• 1 - Indicates a transferred call.

• 2 - Indicates a call with a problem reported.

• 3 - Indicates a transferred call with a problem reported.

This section shows the origination type code and the call origination type.

• 00 - Unspecified.

• 01 - Indicates a Local Directory Assistance call (the subscriber dialed411).

• 02 - Indicates a HNPA DA call (the subscriber dialed 1+555-1212).

• 03 - Indicates a FNPA DA call (the subscriber dialed l+NPA+555-1212).

• 04 - Indicates a traffic operator dialed 131 to ask for assistance from anAOSS operator.

• 05 - Indicates a traffic operator dialed 141 to obtain rate and routeinformation from an AOSS operator.

• 06 - Indicates a call an AOSS operator intercepts.

• 07 - Indicates an ACS operator keys to access a forward number.

Remedial actionn/a

AMAB118 243

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 244: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatAMAB118 mmmdd hh:mm:ss ssdd INFO AOSS VR CALL ENTRY

B8 ec ce sf dn fwddn day hhmmss oprn tn ct co n chd

Selected field descriptionsField Value Fixed or

VariableDescription

INFO AOSS VR CALLENTRY

Constant Fixed Indicates a report of data associatedwith the AOSS Voice Responsesystem.

B8 Constant Fixed Identifies an AOSS VR CALL ENTRYrecord type.

ec 00-99 Variable Identifies the entry code. See Table R.

ce (0-7), (0-7) Variable Indicates call event Information. Digitone is on the left. Refer to Table Callevent information in log reportAMAB100.

sf (0-7), (0-7) Variable Indicates service features of callingparty (left digit) and the forward party(right digit). Refer to Table Servicefeatures in log report AMAB100.

dn Symbolic text Variable Identifies calling number. See Table I.

fwddn 2-10 digits Variable Identifies the forward or requestednumber the operator enters.

day 1-366 Variable Indicates the day of the year on whichthe call arrived at the AOSS position.

hhmmss 000000-235959 Variable Indicates the time of the day when thecall arrived at the AOSS position.

oprn 0000-9999 Variable Identifies AOSS operator handling thecall.

tn 00-99 Variable Identifies the team that the systemassigns to the AOSS operator.

ct (0-5), (0-3) Variable Provides charge, transfer, and troubleinformation about the AOSS call thesystem handles. Digit 1 (left)represents charge details. Refer toTable Charge details at the end of thislog report. Digit 2 represents transfer

244 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 245: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

and trouble details. Refer to TableTransfer and Trouble Details at theend of this log report.

co 00-07 Variable Indicates origination manner of a callto an AOSS operator. Refer to TableCall Origination Type table at the endof this log report.

n 0 Variable Indicates the call is not a recall nor acut-through.

1 Variable Indicates a call the operator recalls.

2 Variable Indicates a call cut through to theoperator.

chd 0-255 Variable Indicates downstream chargedetermination.

Active message exampleAMAB118 MAY11 12:23:52 2112 INFO AOSS VR CALL ENTRY

B8 00 24 00 321234 62177 003 094032 0212 02 00 01 1 057

Clear message examplen/a

Associated OM registers

AMAB119The Automatic Message Accounting Buffer (AMAB) subsystem generatesreport AMAB119 as required. This report provides information aboutdirectory assistance and intercept (DA/INT) AMA records.

Remedial actionAction not required. This log is for information and testing.

AttributesAttribute Value

Severity Warning

FormatAMAB119 mmmdd hh:mm:ss ssdd INFO DA_INT_B8_ENTRY

rec code: nn entry code: nn info digs 1,2: nn

AMAB119 245

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 246: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

orig serv feat: n term serv feat: n clg num: dn cld num: dn

ddd hh:mm:ss oper num: nnnn team num: nn info digs 3,4: nn

orig:nn recall: n listing fig: nnn

Selected field descriptionsField Value Fixed or

VariableDescription

Term serv feature 0 Variable Identifies the service feature of theterminator of the call. This field willalways be set to 0.

CIg num Integers Variable Provides the directory number of thecalling party for a DA call. In case ofan INT call, indicates the originaldialed number. Refer to Table I.

CId num Integers Variable Provides the directory number of thecalled party. Refer to Table I.

DDD 1-365 Variable Identifies the day of the year the callarrives at the operator position.

Hh:mm:ss Variable Indicates time that the call arrives atthe operator position.

Oper num Integers Variable Identifies the number of the DAoperator logged in at the positionwhere the system handles the DA/INTcall. The system records zero whenthe call does not involve an operator.

Team num Integers Variable Identifies the team number of theoperator who handled the DA/INT call.The system records zero in the caseof auto intercepted calls and when thecall does not involve an operator.

Info dig 3 Integers Variable Identifies the charge details for theDA/INT call. Tables TOPS,DATAKOPT DABILL, and if theoperator does not strike the NO AMAkey, will determine the charge of thecall. Refer to Table Charge details atthe end of this log report.

Info dig 4 Integers Variable Indicates if the call transferred fromanother operator and if the systemreports a problem on the call. Refer toTable Condition at the end of this logreport.

246 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 247: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Orig Variable Identifies the call type. Refer to TableTOPSAMA.

Recall 0-2 Variable Indicates if the call becomes a recallor a cut through

Listing fig 0-255 Variable Indicates the information the DASprovides.

INFODA_INT_B8_ENTRY

Constant Fixed Indicates a report of Traffic OperatorPosition System Multipurpose (TOPSMP) entry DA/INT AMA service.

Rec code B8 Variable Indicates the type of call beingrecorded on AMA tape. Willconsistently contain B8 for this type ofrecord.

Entry code 00 Variable Identifies the type of billing used onthe call. For DA/INT calls, the systemuses one type of billing and the valuefor this field is always 00.

Info digs 1 0-3 Variable Indicates if the call is subject toservice analysis and if a charge isapplicable.

Info digs 2 0, 2, 4, 5, 6 Variable Indicates the automatic numberidentification (ANI) of the call.

Orig serv feat 0-2 Variable Identifies the service feature of theoriginator of the call. This informationis based on the ANI received from theend office. Refer to Table Servicefeatures at the end of log reportAMAB100.

Active message exampleAMAB119 JAN03 13:41:02 4712 INFO DA_INT_B8_ENTRY

B8 00 24 00 6132321234 6217777*** 003 094932 0212

02 00 01 1 057

Clear message examplen/a

AMAB119 247

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 248: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AMAB122The Automatic Message Accounting Buffer (AMAB) subsystem generateslog report AMAB122. The report gives a detailed description of call data foran incoming routine exercise test (ICREXT) call entry record. Use the logfor debugging.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAMAB122 mmmdd hh:mm:ss ssdd INFO ICREXT LOG ENTRY

rc cc cm fc sc FFFFdn FFFFdn yymmdd

hhmmss durtxt pulstxt ictrkid ogtrkid

Selected field descriptionsField Value Fixed or

VariableDescription

INFO ICREXT LOGENTRY

Constant Fixed Indicates that the following data willproduce a ICREXT call entry record

rc BB Variable This is the record code and is aconstant BB for this log report.

cc two digit Variable This is the call class:

• 00 -- NIL class

• 01 -- UNKW (unknown) class

• 02 -- IAGRP (intragroup) class

• 03 -- ATT (attendant)

• 04 -- DATT (dial attendant)

• 05 -- LCL (local)

• 06 -- SPEC (special call)

• 07 -- EMRG (emergency call)

• 08 -- NATL (national)

248 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 249: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

• 09 -- CNTL (continental)

• 10 -- ICNTL (intercontinental)

• 11 -- INTL (international)

• 12 -- OPRA (operator assistedcall)

• 13 -- IOPRA (internationaloperator assisted call)

cm 00 Variable This is the call mode, for this log it is aconstant 00.

fc two digits Variable This is the service feature code. Thefirst digit indicates the events duringthe call:

• 0 -- call was not answered,analyzed, or charged

• 1 -- call was answered

• 2 -- call was service analyzed

• 3 -- call was answered andservice analyzed

• 4 -- call was charged

• 5 -- call was answered andcharged

• 6 -- call was service analyzed andcharged

• 7 -- call was answered, serviceanalyzed, and charged

The second digit indicates the callstatus:

• 0 -- call is successful

• 1 -- call is successful, butmetering information lost

• 2 -- call failed and meteringinformation lost

• 3 -- malicious call trace, callduration data invalid

AMAB122 249

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 250: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

sc two digits Variable This is the special services code:

• 00 -- default standard line

• 01 -- coin box informationobtained from line attributes

• 02 -- addon leg

• 03 -- call diversion leg

FFFFdn Integers Variable Indicates the calling number

FFFFdn Integers Variable Indicates the called number

yymmdd Integers Variable Indicates year, month, and day of call

hhmmss Integers Variable Indicates time of call

durtxt Integers Variable Indicates length of call in seconds

pulstxt Integers Variable Indicates number of pulses the callreceives.

ictrkid Symbolic text Variable Identifies the incoming trunk groupthat represents the position in TableTRKGRP. A value of 2047 indicates aline. The value 8191 indicates a null ornot applicable (NA) value for a trunkgroup number. Refer to customer dataTable TRKGRP.

ogtrkid Symbolic text Variable Identifies the outgoing trunk group thatrepresents the position in TableTRKGRP. A value of 2047 indicates aline. The value 8191 indicates a null ornot applicable (NA) value for a trunkgroup number. Refer to customer dataTable TRKGRP.

Active message exampleAMAB122 SEP18 11:01:18 3232 INFO ICREXT LOG ENTRY

BB 05 00 50 00 FFFF180986 FFFF99496116662000 860316

110118 00000354 00000037 0120 2047

Clear message examplen/a

250 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 251: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AMAB150The Automatic Message Accounting Buffer (AMAB) subsystem generatesreport AMAB150. The report tests or monitors the generation of StationMessage Detail Recording (SMDR) records. The information in the reportand the file (on tape or disk) is the same. Refer to Meridian Digital CentrexStation Message Detail Recording Reference Guide, 297-2071-119, foradditional information.

The log report is different than the format and example described herebecause of space limits in this manual.

Remedial actionThere is no action required. If the system records multipleSMDR_CALL_DATA files for the call, the second SMDR file contains aterminating format code of six. This code means the call can have any ofthe answer types. The code also indicates that a call has more than oneSMDR file.

AttributesAttribute Value

Severity Warning

FormatAMAB150 mmmdd hh:mm:ss ssdd INFO SMDR_CALL_DATA

CUSTGRP= cgrptxt

nnndn oa nn n dn ta n n

dn ddd hh mm ss ssssss

ORIG = cktid TERM = CKT cktid

ANS=txt n

DTO = nnnn....nnn AUTH = nnnn....xxx

ACC = nnnn....xxx

AMAB150 251

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 252: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

************** Variable Indicates the user did not dial anauthorization code.

ACC=nnnn....xxxx Up to 14 digits,leftjustified, padded withXXXX

Variable Indicates the account code.

NNNNYYYY Variable Indicates expensive route.

dn Variable Indicates called number. The digitsthe originator dialed. Refer toExplanation.

ddd 0 - 365 Variable Indicates the day when the callstarted.

hh 0 - 23 Variable Indicates the hour of the day when thecall started.

mm 0 - 59 Variable Indicates the minute when the callstarted,

ss 0 - 59 Variable Indicates the second when the callstarted,

ssssss 0-999999 Variable Provides the duration of the call inseconds.

ORIG = cktid See Table 1. Variable Indicates the line or trunk of theoriginator.

TERM = cktid See Table 1. Variable Indicates the line or trunk of theterminator.

ANS=txt Y Variable Indicates the call was answered.

N Variable Indicates the call was not answered.

n Variable Provides the answer type if the callwas answered.

0 Variable Indicates electrical answer.

1 Variable Indicates fake answer.

2 Variable Indicates tone answer.

3 Variable Indicates default answer.

DTO=nnn...nnnn Up to 30 digits**********************

Variable Indicates the digits the system is tooutpulse.

Indicates the system does not record.

AUTH=nnnn....xxxx Up to 14 digits, leftjustified, padded withXXXX.

Variable Indicates the authorization code.

252 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 253: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

INFOSMDR_CALL_DATA

Constant Fixed Indicates this report contains SMDRcall data.

CUSTOMER GROUP Character string Variable Indicates originating IntegratedBusiness Network (IBN) customergroup. Refer to Table CUSTMDR inthe data schema section of theTranslations Guide .

n 0-7 Variable Indicates originator subgroup.

n 0 Variable Provides the SMDR feature code ofthe originator.

2 Variable Indicates default.

3 Variable Indicates three-way conference, orcall forward.

Numeric Variable Indicates six-way conference,attendant, or meet me.

4 Variable Indicates call park retrieval.

6 Variable Indicates multiple answer.

8 Variable Indicates preset conference.

9 Variable Indicates group interconnection call.

n Numeric Variable Indicates the call origination type.

0 Variable Indicates Station.

1 Variable Indicates Station with special billing(SPB) option.

2 Variable Indicates Attendant console.

3 Variable Indicates Trunk.

4 Variable Indicates direct inward system access(DISA) directory number (DN).

5 Variable Indicates virtual facility group.

6 Variable Indicates 6-port conference originator.

7 Variable Indicates automatic numberidentification (ANI) for FGN trunk.

8 Variable Indicates automatic identified outwarddialing (AIOD).

#A Variable Indicates not known.

dn Symbolic text Variable Indicates the station dialed number orcustomer group billing number. If theorigination type is 3 trunk, the systemgenerates the ten-digit billing DN. The

AMAB150 253

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 254: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ten-digit DN is from Table Trunkgroup. The system does not generatethe calling DN at this time. If the userdoes not enter the billing DN, this fieldcontains 10 stars. If the NETWORKoption is assigned in TableCUSTSMDR, the calling DN forincoming ISUP IBN calls appears inthis field.

Symbolic text Variable Indicates 10-digit ANI for featuregroup D (FGD) trunks.

oa 0 Variable Indicates a voice call.

2 Variable Indicates a data call, modem poolingnot used.

3 Variable Indicates a data call, modem poolingused.

A Variable Indicates type of call not known, orfeature is inactive. A *in this field alsoindicates feature is inactive.

nn Variable Provides information digits.

Digit 1 hexadecimal (0to F)

Variable • 0 = call not service analyzed, ANIdid not fail, call not answered, andnot VPN on-net

• 1= call service analyzed

• 2 = call ANI failed

• 3 = call service analyzed and ANIfailed

• 4 = call answered

• 5 = call service analyzed andanswered

• 6 = call ANI failed and answered

• 7 = call service analyzed, ANIfailed, and call answered

• 8 = call is VPN on-net

• 9 = call analyzed and VPN on-net

• A = call ANI failed and VPN on-net

254 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 255: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

• B = call service analyzed, ANIfailed, and VPN on-net

• C = call answered and VPN on-net

• D = call service analyzed,answered, and VPN on-net

• E = call ANI failed, answered, andVPN on-net

• F = call service analyzed, ANIfailed, answered, and VPN on-net

Digit 2 Variable Indicates digit 2.

NYNY Variable Indicates CId Party Disc.

NNYY Variable Indicates Attendant Extended.

n Variable Provides the call termination type.

4 Variable Indicates DISA_DN.

dn Integers Variable Indicates the station DN if theterminator is a line. Refer toExplanation.

ta Refer to theexplanation for oa.

Variable Provides the terminator data callidentification digit.

n Variable Provides the SMDR feature code ofthe originator.

0 Variable

1 Variable Indicates default.

3 Variable Indicates call forwarding.

Variable Indicates 6-port conference, attendantor Meet me.

5 Variable Indicates call-back queuing.

Indicates ring-again.

Indicates multiple answer.

6 Variable Indicates flexible station controlledconference.

7 Variable Indicates preset conference.

8 Variable Indicates call request retrieval.

10 Variable

AMAB150 255

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 256: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

n 01234567 Variable Indicates the route information digit.

--------- Variable

NYNYNYNY Variable Indicates digits missing.

NNYYNNYY Variable Indicates automatic route selection(ARS) selected route.

Active message exampleAMAB150 JUL03 15:25:29 6707 INFO SMDR_CALL_DATA

CUSTGRP = COMKODAK

0 0 0 6137227000 ** 40 3 ********** ** 0 0

4327020***************** 002 06 55 08 000009

ORIG = HOST 00 0 02 03 DN 9097255388 TERM = CKT OGMF 1

ANS= Y 0

DTO = 27020******************* AUTH = *************

ACC = **********

Clear message examplen/a

Associated OM registers

AMAB151The Automatic Message Accounting Buffer (AMAB) subsystem generateslog report AMAB151. The report appears if an identification failure occurswhen an ORIG terminal creates a Station Message Detail Recording(SMDR) record for a call.

Digit value:

The following information specifies the Digit values where Y = bit set, eventoccurred, N = bit not set, event did not occur:

Digit value - 0 -- Service analyzed - N -- ANI failed - N -- Call answered - N-- VPN on-net - N

256 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 257: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Digit value - 1 -- Service analyzed - Y -- ANI failed - N -- Call answered - N-- VPN on-net - N

Digit value - 2 -- Service analyzed - N -- ANI failed - Y -- Call answered - N-- VPN on-net - N

Digit value - 3 -- Service analyzed - Y -- ANI failed - Y -- Call answered - N-- VPN on-net - N

Digit value - 4 -- Service analyzed - N -- ANI failed - N -- Call answered - Y-- VPN on-net - N

Digit value - 5 -- Service analyzed - Y -- ANI failed - N -- Call answered - Y-- VPN on-net - N

Digit value - 6 -- Service analyzed - N -- ANI failed - Y -- Call answered - Y-- VPN on-net - N

Digit value - 7 -- Service analyzed - Y -- ANI failed - Y -- Call answered - N-- VPN on-net - N

Digit value - 8 -- Service analyzed - N -- ANI failed - N -- Call answered - N-- VPN on-net -Y

Digit value - 9 -- Service analyzed - Y -- ANI failed - N -- Call answered - N-- VPN on-net - Y

Digit value - A -- Service analyzed - N -- ANI failed - Y -- Call answered - N-- VPN on-net - Y

Digit value - B -- Service analyzed - Y -- ANI failed - Y -- Call answered - N-- VPN on-net - Y

Digit value - C -- Service analyzed - N -- ANI failed - N -- Call answered - Y-- VPN on-net - Y

Digit value - D -- Service analyzed - Y -- ANI failed - N -- Call answered - Y-- VPN on-net - Y

Digit value - E -- Service analyzed - N -- ANI failed - Y -- Call answered - Y-- VPN on-net - Y

Digit value - F -- Service analyzed - Y -- ANI failed - Y -- Call answered - Y-- VPN on-net - Y

AMAB151 257

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 258: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionThis report indicates that the special billing number for station ORIG hasless than seven digits. This report indicates that if ORIG is an attendantconsole, the customer group billing number has less than seven digits. IfORIG is a trunk, check the billing number in the trunk group data. If ORIGis not a trunk, report the problem to your maintenance support group.

AttributesAttribute Value

Severity Indeterminate

FormatAMAB151 mmmdd hh:mm:ss ssdd FAIL SMDR_ANI_FAIL

ORIG <len>DN dn

Selected field descriptionsField Value Fixed or

VariableDescription

FAILSMDR_ANI_FAIL

Constant Fixed Indicates an automatic numberidentification (ANI) failure duringcreation of an SMDR record.

ORIG LEN Integers Variable Indicates the line equipment number(LEN).

DN Integers Variable Provides the calling number.

Active message exampleAMAB151 SEP16 10:55:13 3932 FAIL SMDR_ANI_FAIL

ORIG HOST 00 1 05 03 DN 6157655360

Clear message examplen/a

Associated OM registers

AMAB153The Automatic Message Accounting Buffer (AMAB) subsystem generatesreport AMAB153. The report verifies that the system generated the calldetail record for toll calls. This log is optional. Use office parameterGEN_ICR_LOG_ENTRY in Table OFCVAR to produce this log. Use thisreport for debugging.

258 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 259: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAMAB153 mmmdd hh:mm:ss ssdd INFO ICR LOG ENTRY

dn**** dn yyddmm hhmmss nnnnnnnn

nnnnnnnn nn nn nn

Selected field descriptionsField Value Fixed or

VariableDescription

INFO ICR LOGENTRY

Constant Fixed Indicates that the following is a detailrecord for a toll call.

dn Any valid directorynumber (DN)

Variable Indicates the calling number.

dn Any valid DN Variable Indicates the called number.

yymmdd Any valid date. Variable Indicates date of call.

hhmmss Any valid time. Variable Indicates the time the call wasanswered. If the call was notanswered, indicates the time the callbegan.

nnnnnnnn 0-99999999 Variable Indicates the duration of the call. If thecall was not answered, indicates thetime the call was in ringing mode.

nnnnnnnn 0-99999999 Variable Indicates pulse count.

STATUS_CODE Variable Indicates status code.

00 Variable Indicates call completion. All data isvalid.

01 Variable Indicates call completion. Meteringdata lost or invalid.

02 Variable Indicates call failure. Metering datalost or invalid.

03 Variable Indicates call failure. Metering dataand call duration lost or invalid.

AMAB153 259

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 260: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

FEATURE_CODE Variable Indicates feature code. Any specialservice features the call originatorowns.

00 Variable Indicates standard line.

01 Variable Indicates coin box.

02 Variable Indicates three-way call leg.

03 Variable Indicates call diversion leg.

CALL_INFO Variable Indicates call information.

00 Variable Indicates answered call.

01 Variable Indicates chargeable call.

02 Variable Indicates call not charged.

Active message exampleAMAB153 NOV26 11:32:06 3231 INFO ICR LOG ENTRY

BA ****180986****99496116662000 870716 113206

00000082 00 00 01

Clear message examplen/a

Associated OM registers

AMAB154The Automatic Message Accounting Buffer (AMAB) subsystem generateslog report AMAB154. This report appears when the toll call recordingfacility attempts to record a call, but not enough recording units areavailable.

The system allows the call to continue if this log appears, but the systemdoes not record.

Remedial actionIncrease the number of recording units allocated for this office in TableOFCENG.

AttributesAttribute Value

Severity Warning

260 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 261: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FormatAMAB154 mmmdd hh:mm:ss ssdd INFO ICR RU OVFL LOG

MAX RU: nnnnn ORIG: dn, DEST: dn

Selected field descriptionsField Value Fixed or

VariableDescription

INFO ICR RU OVFLLOG

Constant Fixed Indicates not enough toll call recordingunits are available to record the call.

MAX RU 0-32767 Variable Indicates the number of recordingunits with office-defined parameteravailable.

ORIG Integers Variable Indicates the calling number.

DEST Integers Variable Indicates the called number.

Active message exampleAMAB154 NOV26 11:32:06 3231 INFO ICR RU OVFL LOG

MAX RU: 25, ORIG: 180986, DEST: 99496116662000

Clear message examplen/a

Associated OM registers

AMAB155The Automatic Message Accounting Buffer (AMAB) subsystem generateslog report AMAB155. The report tests or monitors the Station MessageDetail Recording (SMDR) records generated. The information in the reportand in the file on tape or disk is the same. Refer to Automatic MessageAccounting Northern Telecom Format, 297-2001-119, for additionalinformation.

The information contained in this report is the same as in log AMAB150.Log AMAB155 has an additional line that gives metering pulse countsreceived for a call. The metering pulse count information is for trunks thatuse Spanish multifrequency signaling (MFE) SOCOTEL. The systemmeters all calls that involve outgoing SOCOTEL trunks from a Spanishoffice.

AMAB155 261

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 262: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

If the system records multiple SMDR_CALL_DATA files for the call, thesecond SMDR file contains a terminating format code of six. This codemeans the SMDR file can have any of the answer types. The code alsoindicates more than one SMDR file per call.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAMAB155 mmmdd hh:mm:ss ssdd INFO SMDR_CALL_DATA

CUSTOMER GROUP= cgrptxt

n n n dn orig_acno nn n

dn term_acno n n dn nnn nn nn nn nnnnnn

ORIG = len trkid TERM CKT = trkid ANS=txt n

DTO=nnnn....nnn AUTH=nnnn....xxx ACC=nnnn....xxx

MTR=nnnnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

INFOSMDR_CALL_DATA

Constant Fixed Indicates that this report containsSMDR call data.

CUSTOMER GROUP A 1-16 character Variable Indicates originator IBN. Name CLLIassigned to the customer group. Referto Table CUSTOMER in LocalCustomer Data Schema ,297-2101-451, for additionalinformation.

n 0-7 Variable Indicates originator subgroup.

n 0 2 3 4 6 8 9 Variable Indicates the SMDR feature code ofthe originator.

Indicates Default.

Indicates three-way conference, orcall forward.

262 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 263: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Indicates six-way conference,attendant, or meet me.

Indicates call park retrieval.

Indicates multiple answer.

Indicates preset conference.

Indicates group interconnection call.

n 0 1 2 3 4 5 6 #A Variable Indicates the call origination type.

Indicates Station.

Indicates Station with Special Billing(SPB) option.

Indicates Attendant console.

Indicates Trunk.

Indicates direct inward system (DISA)directory number (DN).

Indicates virtual facility group.

Indicates 6-port conference originator.

Indicates not known.

dn Variable Indicates Station DN, or customergroup billing number. Refer to Table I.

********** Variable Indicates a Trunk.

orig_acno 0-255 Variable Indicates the console number if anATTENDANT ORIGINATED or anATTENDANT EXTENDED call. Thevalue is binary.

nn Digit 1 Variable Indicates information digits.

01234567 Variable Indicates digit 1 is left digit.

--------- Variable ---------

NYNYNYNY Variable Indicates service analyzed.

NNNNYYYY Variable Indicates automatic numberidentification (ANI) failure.

NNNNYYYY Variable Indicates answered.

Digit 2 Variable Indicates digit 2.

NYNY Variable Indicates cld party disc.

NNYY Variable Indicates Attendant Extended.

n Variable Provides the call termination type.

AMAB155 263

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 264: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

0 Variable Indicates Station.

2 Variable Indicates Attendant console.

3 Variable Indicates Trunk.

4 Variable Indicates DISA_DN.

5 Variable Indicates virtual facility group.

#A Variable Indicates not known.

dn Variable Indicates Station DN, if the terminatoris a line. Refer to Table I.

term_acno 0-255 Variable Indicates console number, if theterminator is an attendant consolewith binary value.

n 0 1 3 5 6 7 8 Variable Indicates the feature code of theterminator.

Indicates default.

Indicates call forwarding

Indicates 6-port conference circuit,attendant 5 or meet me.

Indicates call-back queuing or ring-again.

Indicates multiple answer.

Indicates flexible station-controlledconference.

Indicates preset conference.

n 01234567 ---------NYNYNYNYNNYYNNYYNNNNYYYY

Variable Indicates route information digit.

Indicates digits not present.

Indicates automatic route selection(ARS) selected route.

Indicates expensive route.

dn Variable Indicates called number. The digitsthat the originator dialed. Refer toTable I.

nnnnnnnnn (0-365), (0-23),(0-59), (0-59)

Variable Indicates start time in days, hours,minutes and seconds.

nnnnnn (0-23), (0-59), (0-59) Variable Indicates elapsed time associated withthe call in the form of hours, minutesand seconds.

264 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 265: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ORIG = len trkid See Table I. Variable Indicates the CLLI of the originator,and the line equipment number (LEN).

TERM = trkid See Table I. Variable Indicates the CLLI and circuit numberof the terminator.

ANS=txt Variable Indicates if the call was answered.

Y Variable Indicates YES.

N Variable Indicates NO.

n Variable Indicates answer type, if call wasanswered.

0 Variable Indicates electrical answer.

1 Variable Indicates fake answer.

2 Variable Indicates tone answer.

3 Variable Indicates default answer.

DTO=nnn...nnnn Up to 23 digits Variable Indicates the digits the system willoutpulse.

******************* Variable Indicates if the system does notrecord the call.

**** Variable

AUTH=nnnn....xxxx Up to 14 digits, leftjustified, padded with'x's.

Variable Indicates the authorization code.

************** Variable Indicates that the user did not dial anauthorization code.

ACC=nnnn....xxxx Up to 14 digits, leftjustified, padded with'x's.

Variable Indicates the account code.

MTR=nnnnnnnnnn Up to 10 digits, rightjustified.

Variable Indicates number of meter pulsecounts received from time of answer,to time that the clear-back message isreceived.

Active message exampleAMAB155 SUN07 10:55:20 1599 INFO SMDR_CALL_DATA

CUSTOMER GROUP= NV

0 0 0 8058662400 00 40 0 ********* 00 0 0

62181 ********* 153 12 33 34 000071

AMAB155 265

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 266: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

ORIG= LEN MHD1 01 1 18 00 DN 62400 TERM= CKT SOCPOG ANS = Y0

DTO=*********** AUTH= ********** ACC= **********

MTR=0000000365

Clear message examplen/a

Associated OM registers

AMAB160The Automatic Message Accounting Buffer (AMAB) subsystem generatereport AMAB160. This report contains call data that produce a call entryrecord for an international centralized automatic message accounting(ICAMA).

The calling number for BD record is always set to all Fs. The callingnumber for BD record is always set to all Fs.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAMAB160 mmmdd hh:mm:ss ssdd INFO ICAMA_LOG_ENTRY

rc cc cm ci sc FFFFFdn FFFFdn yymmdd

hhmmss durtxt pulstxt ictrkid ogtrkid

266 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 267: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFOICAMA_LOG_ENTRY

Constant Fixed Provides a complete description of calldata.

rc two character Variable This is the record code:

• BC = ICAMA

• BD = International, InterAdministration Accounting (IAA)record

cc two digit Variable This is the call class:

• 00 -- NIL class

• 01 -- UNKW (unknown) class

• 02 -- IAGRP (intragroup) class

• 03 -- ATT (attendant)

• 04 -- DATT (dial attendant)

• 05 -- LCL (local)

• 06 -- SPEC (special call)

• 07 -- EMRG (emergency call)

• 08 -- NATL (national)

• 09 -- CNTL (continental)

• 10 -- ICNTL (intercontinental)

• 11 -- INTL (international)

• 12 -- OPRA (operator assistedcall)

• 13 -- IOPRA (internationaloperator assisted call)

cm 00 Variable This is the call mode, for this log it is aconstant 00 and indicates a station-to-station call.

ci two digits Variable This is the call info code. The first digitindicates the events during the call:

• 0 -- call was not answered,analyzed, or charged

• 1 -- call was answered

• 2 -- call was service analyzed

AMAB160 267

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 268: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

• 3 -- call was answered andservice analyzed

• 4 -- call was charged

• 5 -- call was answered andcharged

• 6 -- call was service analyzed andcharged

• 7 -- call was answered, serviceanalyzed, and charged

The second digit indicates the callstatus:

• 0 -- call is successful

• 1 -- call is successful, butmetering information lost (this fielddoes not apply to ICAMA)

• 2 -- call failed and meteringinformation lost

• 3 -- malicious call trace, callduration data invalid

• 4 -- ICAMA, automatic numberidentification (ANI) failure

• 5 -- ICAMA, ANI failure reportedby originating office.

sc two digits Fixed This is the service feature code and isa constant 00 for this log report.

dn Symbolic text Variable Indicates the calling number. Refer toExplanation.

yymmdd Integers Variable Indicates year, month and day of call.

hhmmss Integers Variable Indicates time of call.

durtxt 000000000-999999999

Variable Indicates length of call in seconds.

pulstxt 000000000 Variable Indicates number of pulses receivedfor the call.

ictrkid Integers Variable Indicates the incoming trunk groupthat describes the position in TableTRKGRP. The position numbers from

268 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 269: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

zero. A value of 2047 indicates a line.Refer to customer data TableTRKGRP.

ogtrkid Integers Variable Indicates the outgoing trunk group thatdescribes the position in TableTRKGRP. The position numbers fromzero. A value of 2047 indicates a line.Refer to customer data TableTRKGRP.

Active message exampleINTLUK AMAB160 SEP18 11:01:18 3232 INFO ICAMA LOG ENTRY

BC 09 00 50 00 FFFFF80986 FFFF99496116662000 860316

110118 00000354 00000000 0120 0234

Clear message examplen/a

Associated OM registers

AMAB161The Automatic Message Accounting Buffer (AMAB) subsystem generateslog report AMAB161. The report appears when the international centralizedautomatic message accounting (ICAMA) feature facility attempts to recorda call. Not enough recording units are available at this time. If this logoccurs, it allows the call to continue if the office parameterINTL_RU_OVFL_ACTION is set to CONTINUE. The system does notrecord.

Remedial actionIncrease the number of recording units allocated for this office. Officeparameter NUM_ICAMA_RECORDING_UNITS controls the number ofrecording units.

AttributesAttribute Value

Severity Warning

FormatAMAB161 mmmdd hh:mm:ss INFO_ICAMA_RU_OVFL

AMAB161 269

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 270: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

MAX RU: nnnnn ORIG: dn DEST dn

Selected field descriptionsField Value Fixed or

VariableDescription

INFO_CAMA_RU_OVFL

Constant Fixed Indicates not enough call recordingunits are available to record the call.

MAX RU 0 - 32767 Variable Indicates number of recording unitsavailable with an office-definedparameter.

ORIG Integers Variable Indicates the calling number.

DEST Integers Variable Indicates the called number.

Active message exampleAMAB161 NOV26 11:32:06 3231 INFO ICAMA RU OVFL LOG

MAX RU: 25, ORIG: 180986, BEST: 99496116662000

Clear message examplen/a

Associated OM registers

AMAB180The Automatic Message Accounting Buffer (AMAB) subsystem generateslog report AMAB180. This report contains call data used to produce a calldetails entry record for an International Traffic Operator Position System(ITOPS).

Office parameter GENERATE_ITOP_LOG_ENTRY in Table OFCVARgenerates AMAB180.

INFORMATION DIGIT ONE

• 0 = ANI did not fail, the operator did not dial the number, and theoperator did not identify the number

• 1 = ANI failed

• 2 = operator dialed the called number

• 3 = ANI failed and the operator dialed

• 4 = operator identified the number

270 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 271: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• 5 = ANI failed and the operator identified the number

• 6 = operator dialed the called number and identified the number

• 7 = ANI failed, operator dialed the called number and identified thenumber

INFORMATION DIGIT TWO

• 0 = call was not answered, did not fail after complete call setup, andwas not service analyzed

• 1 = call was answered

• 2 = call failed after complete call setup

• 3 = call was answered and failed after complete call setup

• 4 = call was service analyzed

• 5 = call was answered and service analyzed

• 6 = call failed after complete call setup and call was service analyzed

• 7 = call was answered, failed after complete call setup, and wasservice analyzed

INFORMATION DIGIT THREE

• 0 = call does not include a trouble report, does not include a chargeadjustment, and a connect event occurs on the call

• 1 = call includes a trouble report

• 2 = call includes a charge adjustment

• 3 = call includes a trouble report and a charge adjustment

• 4 = a connect event did not occur on the call

• 5 = call includes a trouble report and a connect event did not occur onthe call

• 6 = call includes a charge adjustment and a connect event did notoccur on the call

• 7 = call includes a trouble report, a charge adjustment, and a connectevent did not occur on the call

AMAB180 271

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 272: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

INFORMATION DIGIT FOUR

• 0 = operator does not bill the call at the direct rate, system does notdetermine that the call is not chargeable, and the operator does notenter the call as not chargeable

• 1 = operator bills the call at the direct dial rate

• 2 = system determines the call is not chargeable

• 3 = operator bills the call at the direct dial rate and the systemdetermines the call is not chargeable

• 4 = operator enters the call as not charged

• 5 = operator bills the call at the direct dial rate and the operator entersthe call as not charged

• 6 = system determines the call is not chargeable and the operatorenters the call as not charged

• 7 = operator bills the call at the direct dial rate, system determines thecall is not chargeable, and the operator enters the call as not charged

INFORMATION DIGIT FIVE

• 0 = call was not transferred, cancel timing key was not in effect, andcancel call key was not in effect

• 1 = call was transferred

• 2 = cancel timing key was in effect

• 3 = call was transferred and cancel timing key was in effect

• 4 = cancel call key was in effect

• 5 = call was transferred and cancel call key was in effect

• 6 = cancel timing and cancel call keys were in effect

• 7 = call was transferred and cancel timing and cancel call keys were ineffect

INFORMATION DIGIT SIX

• 0 = operator does not use toll break in (TBI) to verify calling number,not a trunk offering TBI call, and operator does not overwrite theforward number for security reasons

• 1 = operator uses TBI to verify the calling number

• 2 = call is a trunk offering TBI call

272 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 273: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• 3 = operator uses TBI to verify the calling number and call is a trunkoffering TBI call

• 4 = operator overwrote the forward number for security reasons

• 5 = operator uses TBI to verify the calling number and operatoroverwrites the forward number for security reasons

• 6 = call is trunk offering TBI call and operator overwrote the forwardnumber for security reasons

• 7 = operator used TBI to verify the calling number, call is a trunkoffering TBI call, and the operator overwrote the forward number forsecurity reasons

For digit 6, an example of "call is a trunk offering TBI call" is that theoperator makes the foreign party connection of a requested call and theoperator can break in on the calling party.

Remedial actionThere is no action required. This log report is for information only.

AttributesAttribute Value

Severity Warning

FormatAMAB180 mmmdd hh:mm:ss ssdd ITOPS CALL DETAILS RECORD

ENTRY

BE calltyp origtyp CLG_dn CLD_dn featcode

chrgtyp yymmdd hhmmss drtn n n n n n n opn tmn otrkid itrkid

Selected field descriptionsField Value Fixed or

VariableDescription

ITOPS CALLDETAILS RECORDENTRY

Constant Fixed Indicates this log reports a call detailsrecord.

BE Constant Fixed Provides the record type (BE) of a calldetails entry record.

calltyp 12 Variable Indicates the call class that the systemrecords as an operator-assisted call.

AMAB180 273

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 274: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

13 Variable Indicates the call class that the systemrecords as an international operator-assisted call.

origtyp 00 to 10 Variable Indicates how the call was presentedto the operator:

• 00 - Not specified.

• 01 - Operator assisted.

• 02 - Operator handled.

• 03 - Direct handled

• 04 - Operator intercept.

• 05 - Directory assistance.

• 06 - Inward (another operatororiginated call).

• 07 - Booked call.

• 08 - Special requirements.

• 09 - Delay database originatedcall.

• 10 - Operator originated call.

CLG dn Symbolic text Variable Provides the directory number (DN) ofthe caller. Refer to Explanation.

featcode Integers Variable Provides the station classes of thecalling and called party. The first digitdescribes the calling party stationclass. The second digit describes thecalled party station class.

• 0 = Default (station)

• 1 = Coin

• 4 = Hotel/Motel

• 5 = Mobile

• 6 = Marine

• 7 = Attended Pay Station (APS)

chrgtyp Integers Variable Provides information on how thesystem bills the call:

• 00 - Not specified

• 01 - Cancelled call

274 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 275: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

• 02 - Station paid

• 03 - Station collect

• 04 - Station special calling

• 05 - Station special called

• 06 - Person paid

• 07 - Person collect

• 08 - Person special calling

• 09 - Person special called

• 10 - Person call back

• 11 - Person call back specialbilling

yymmdd 000101-991231 Variable This field provides the date the call isanswered. If the call is not answered,this field provides the date the callarrives at the operator position.

hhmmss 000000 - 235959 Variable This field provides the time the call isanswered. If the call is not answered,this field provides the time the callarrives at the operator position.

drtn 00000000 - 99999999 Variable This field provides the duration of thecall in seconds. If the call is notanswered, this field shows the time,that the call is at the operator position.

opn Integers Variable Indicates the operator that lasthandles the call. Refer to customerdata Table TOPSOPR.

n n n n n n Integers Variable Each "n" represents an informationdigit. These digits provide additionalinformation for each call. Refer to theexplanation of this log report for thedescription of these six informationdigits.

tmn Integers Variable Provides the group number of theoperator that last handled the call.Refer to customer data TableTOPSOPR.

AMAB180 275

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 276: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

otrkid Integers Variable Indicates the outgoing trunk groupnumber that represents the position inTable TRKGRP.

itrkid Integers Variable Indicates the incoming trunk groupnumber that represents the position inTable TRKGRP.

Active message exampleAMAB180 AUG4 02:24:44 1501 ITOPS CALL DETAILS RECORD ENTRY

BE 12 01 6135421263 3053525116 10

02 870703 122324 00000365 4 0 0 2 0 0 0011 02 0210 4321

Clear message examplen/a

Associated OM registers

AMAB181The Automatic Message Accounting Buffer subsystem generates reportAMAB181. This report contains call data that produce a Special Billing(SPB) extension record for an International Traffic Operator PositionSystem (ITOPS).

Office parameter GENERATE_ITOP_LOG_ENTRY in table OFCVARgenerates AMAB181.

This section shows the billing number codes, its values and explanations.

• 0 - National third party

• 1 - National calling card

• 2 - Foreign third party

• 3 - Foreign calling card

• 4 - SPB number for account number billing

Remedial actionThere is no action required. This log is for information only.

276 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 277: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Indeterminate

FormatAMAB181 mmmdd hh:mm:ss ssdd ITOPS SPECIAL BILLING LOG

ENTRY

E6 blgcode blgdig dn

Selected field descriptionsField Value Fixed or

VariableDescription

ITOPS SPECIALBILLING LOG ENTRY

Constant Fixed Indicates a report of a SPB extensionrecord.

E6 Constant Fixed Provides the SPB extension code,which is E6.

blgcode Integers Variable Indicates the type of SPB numberused. Refer to Table Billing numbercodes at the end of this log report.

blgdig 0 Variable Indicates that the operator did notverify the billing number code or thecode was not on the HOTLIST.

1 Variable Indicates that the operator verified thebilling number code.

2 Variable Indicates that the billing number codewas on the HOTLIST.

dn Symbolic text Variable Provides the special billing number towhich the system billed the call. Referto Table I.

Active message exampleAMAB181 AUG04 02:24:44 1501 ITOPS SPECIAL BILLING LOG

ENTRY

E6 0 0 4092345234

Clear message examplen/a

AMAB181 277

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 278: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AMAB182The Automatic Message Accounting Buffer (AMAB) subsystem generateslog report AMAB182. This report contains call data that produces a hotelbilling extension record for an International Traffic Operator PositionSystem (ITOPS).

Office parameter GENERATE_ITOP_LOG_ENTRY in Table OFCVARgenerates AMAB182.

Remedial actionThere is no action required. This log is for information only.

AttributesAttribute Value

Severity Warning

FormatAMAB182 mmmdd hh:mm:ss ssdd INFO ITOPS HOTEL EXTENSION

ENTRY

E7 rmnum gstnm

Selected field descriptionsField Value Fixed or

VariableDescription

INFO ITOPS HOTELEXTENSION ENTRY

Constant Fixed Indicates a report of an ITOPS hotelbilling extension record.

E7 Constant Fixed Provides the extension code for hotelbilling that is E7.

rmnum Any collection of sixnumbers or threeletters that does notexceed six binarycoded decimal digits.

Variable Provides the room number of the hotelto bill.

gstnm Up to 20 letters. Variable Provides the guest name of the partyin the hotel room.

Active message exampleAMAB182 AUG14 03:25:45 1502 INFO ITOPS HOTEL EXTENSION ENTRY

E7 213 MONROE

278 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 279: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

AMAB183The Automatic Message Accounting Buffer (AMAB) subsystem generateslog report AMAB183. This report contains call data that produces anInternational Traffic Operator Position System (ITOPS) charge extensionrecord. All ITOPS calls with time and charges quoted require a chargeextension record. Examples of calls that require a record are as follows:

• calls quoted at call completion

• hotel calls

• attended pay station (APS) calls.

Office parameter GENERATE_ITOP_LOG_ ENTRY in Table OFCVARgenerates AMAB183.

Remedial actionThere is no action required. This log report is for information only.

AttributesAttribute Value

Severity Indeterminate

FormatAMAB183 mmmdd hh:mm:ss ssdd ITOPS CHARGE EXTENSION ENTRY

E8 amount

Selected field descriptionsField Value Fixed or

VariableDescription

ITOPS CHARGEEXTENSION ENTRY

Constant Fixed Indicates a report of an ITOPS chargeextension record.

E8 Constant Fixed Provides the record code (E8) for acharge extension record.

amount A ten-digit decimalnumber

Variable Provides the quoted cost of the call inthe currency of the specified country.

Active message exampleAMAB183 AUG14 04:26:48 1503 ITOPS CHARGE EXTENSION ENTRY

AMAB183 279

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 280: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

E8 0000002356

Clear message examplen/a

Associated OM registers

AMAB184The Automatic Message Accounting Buffer (AMAB) subsystem generateslog report AMAB184. This report contains call data that produces a chargeadjustment extension record for an International Traffic Operator PositionSystem (ITOPS). A call can have a charge adjustment because of a badconnection or a wrong number. The system generates a chargeadjustment extension record when an operator keys in a chargeadjustment sequence.

Office parameter GENERATE_ITOP_LOG_ENTRY in Table OFCVARgenerates AMAB184.

This section shows the charge adjust indicator, its values andexplanations.

• 0 - Indicator not applied.

• 1 - Minutes for credit.

• 2 - Currency amount credited.

• 3 - Metered pulses credited.

• 4 - Credit complete call.

Remedial actionThere is no action required. This log is for information only.

AttributesAttribute Value

Severity Indeterminate

FormatAMAB184 mmmdd hh:mm:ss ssdd ITOPS CHARGE ADJ

EXTENSION ENTRY

E9 time adjtyp adjind amt

280 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 281: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

ITOPS CHARGE ADJEXTENSION

Constant Fixed Indicates a report of an ITOPS chargeadjustment extension record.

E9 Constant Fixed Provides the record code (E9) of anITOPS charge adjustment extensionrecord.

time 0000-2359 Variable Provides the time in hours andminutes, of when the operator keyedin the charge adjustment.

adjtyp 00-99 Variable Provides the customer-controlledreason for the charge adjustment.

adjind Integers Variable Indicates the type of credit thecustomer requested. Refer to TableCharge adjust indicator at the end ofthis log report.

amount 10-decimal digits Variable Indicates the amount of the chargeadjustment.

This field can contain the number ofminutes, the amount of currency, orthe number of metered pulses tocredit. If the charge adjust indicatorfield contains an invalid value or azero, the amount field does notdisplay special information.

Active message exampleAMAB184 AUG14 05:27:49 1504 ITOPS CHARGE ADJ EXTENSION ENTRY

E9 12 11 01 1 0000000010

Clear message examplen/a

Associated OM registers

AMAB185The Automatic Message Accounting Buffer (AMAB) subsystem generateslog report AMAB185. This report contains call data that produces analternate route extension record for the International Traffic OperatorPosition System (ITOPS). Operators use alternate routes to complete callsor reach operators in a foreign country when a direct route is not available

AMAB185 281

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 282: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

A foreign alternate route extension record occurs when an operator keys ina sequence to link an alternate route. The record indicates the division ofcall revenue between the different countries involved in an ITOPS call.

Office parameter GENERATE_ITOP_LOG_ ENTRY in Table OFCVARgenerates AMAB185.

This section shows the values and explanations for this particular logreport.

• 0 - Alternate Route

• 1 - DA

• 2 - Inward Calls

• 3 - Manual (Call terminates on manual trunk).

Remedial actionThere is no action required. This log is for information only.

AttributesAttribute Value

Severity Indeterminate

FormatAMAB185 mmmdd hh:mm:ss ssdd ITOPS ALT ROUTE EXTENSION

ENTRY

EA cntcode rtetyp

Selected field descriptionsField Value Fixed or

VariableDescription

ITOPS ALT ROUTEEXTENSION ENTRY

Constant Fixed Provides alternate route extensionrecord.

EA Constant Fixed Provides the extension code record(EA) used for an alternate routerecord.

282 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 283: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

cntcode 000 - 999 Variable Provides the alternate route countrycode to indicate the country involvedin the alternate route call.

rtetyp Integers Variable Indicates the type of alternate routecall the operator handled. Refer to theTable Alternate route type at the endof this log report.

Active message exampleAMAB185 AUG14 06:29:50 1505 ITOPS ALT ROUTE EXTENSION

ENTRY

EA 001 1

Clear message examplen/a

Associated OM registers

AMAB186The Automatic Message Accounting Buffer (AMAB) subsystem generateslog report AMAB186. This report contains call data that produces adatabase call extension record for the International Traffic OperatorPosition System (ITOPS). All ITOPS calls that arrive at an operatorposition from the delay call database, require a database call extension.

Office parameter GENERATE_ITOP_LOG_ ENTRY in Table OFCVARgenerates AMAB186.

Remedial actionThere is no action required. This log is for information only.

AttributesAttribute Value

Severity Indeterminate

FormatEXTENSION ENTRY

EB dbc

AMAB186 283

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 284: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

ITOPS DATABASECALL EXTENSIONENTRY

Constant Fixed Provides a report of call data used foran ITOPS call.

EB Constant Fixed Provides the record code (EB) for adatabase call extension record.

dbc 00-99 Variable Provides the call class of the databasecall. The customer controls the prioritywith which the operator positionreceives the mapping of the databaseclasses.

Active message exampleAMAB186 AUG14 07:30:44 1506 ITOPS DATABASE CALL EXTENSION

ENTRY

EB 01

Clear message examplen/a

Associated OM registers

AMAB187The Automatic Message Accounting Buffer (AMAB) subsystem generateslog report AMAB187. This report provides the call detail data the systemproduces for the account code extension record of the International TrafficOperator Position System (ITOPS).

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAMAB187 mmmdd hh:mm:ss ssdd INFO ITOPS

ext_code acctcode_digit filler acctcode_dn acctcode_number

284 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 285: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFO ITOPS Constant Fixed Indicates a message that provides calldetail data.

ext_code Constant Fixed Indicates that the definition of theextension code field is EC.

acctcode_digit Integer (0-5) Variable The account code digit describes theresult for account code check.Supported values are:

0 Default

1 Account code entry prohibited (DNnot found in table ACCTCODE)

2 Account code entry rejected (invalidentry against CLG#)

3 Account code entry accepted (validentry against CLG#)

4 Account code entry rejected (invalidentry against SPL#)

5 Account code entry accepted (validentry against SPL#)

filler Constant Fixed This field is not used. The defaultvalue is F.

acctcode_dn Integers Variable Indicates the subscriber number thatmaps to the entered account code.This number is the number next to the"CLG:" or "SPL:" displays.

acctcode_number Integers Variable Indicates that the operator entered thenumber through the ACC key function.

Active message exampleAMAB187 MAR14 12:14:33 4827 INFO ITOPS

EC 3 F ******** 8094200001 ****123456

Clear message examplen/a

AMAB187 285

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 286: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AMAB189The system generates log AMAB189 for calls that involve an ITOPSoperator.

An ITOPS call details record shows each call that arrives at an operatorposition. Extension records show types of operator-handled calls andcontain additional information needed to bill the call.

Some calls require more than one type of extension record. If a call hasassociated extension records, the records immediately follow the calldetails record on the storage device.

The ITOPS call records interact with the billing system and use the DeviceIndependent Recording Package (DIRP) to output the records to tape ordisk. This feature covers the addition of an extension call record for eachcall that involves an ITOPS operator in the DMS200I and DMS100I/DMS200I. The new extension call record supports the ITOPS call detailsrecord for Chinese network. The record gives additional information aboutITOPS calls.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAMAB189 mmmdd hh:mm:ss ssdd ITOPS ADDITIONAL INFO

EXTENSION ENTRY

<extension code><serialnumber><starttime><registername><calling name><billingcategory>

<called name><called starus>

286 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 287: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Extension code EF Variable Indicates the type of record.

Serial number 0 to 999999 Variable Indicates the extension call recordserial number.

Starting time 0 to 24 hours Variable Indicates the time that a call arrives atthe operator.

Register time 0 to 24 hours Variable Indicates the time that a call registers.

Calling name 10 Digits Variable Indicates the name of the callingsubscriber.

Billing category (KA) 0 to 15 Variable Indicates the calling subscriber billingcategory signal. Zero is the first value.

Called name 20 Characters Variable Indicates the name of the calledsubscriber.

Called subscriberstatus (KB)

0 to 6 Variable Indicates the received calledsubscriber status signal.

Active message exampleAMAB189 JUN12 07:27:49 1800 ITOPS ADDITIONAL INFO EXTENSION

ENTRY

EF 000025 071835 071915 GEORGE 1

MARRY 2

Clear message examplen/a

Associated OM registers

AMAB200The Automatic Message Accounting Buffer (AMAB) subsystem generatesthis report when the AMATEST option is enabled for a trunk in TableAMATKOPT, or for a line via SERVORD, with the tuple LOGTEST in TableAMAOPTS set to ON. The log is produced at the same time as the AMArecord. The length of the log is fixed at 13 lines of 60 characters per line.The last six lines contain a hex dump of the call record produced. Somelines may be blank depending on the length of the record. The maximumcall record length handled by this log is 360 characters.

AMAB200 287

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 288: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

This message can occur only in offices with the BCFMT type of AMA inTable CRSFMT. (Refer to Bellcore Format Automatic Message AccountingReference Manual, 297-1001-830.)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAMAB200 mmmdd hh:mm:ss ssdd INFO AMA TEST CALL RECORD

STRUCTURE CODE=

CALLING DN

ORIG AGENT

CALLED DN

TERM AGENT

aaaaa CALL CODE = bbb

= dn1

= orgnum

= orgnum

= CKT CLLI cktnum

Selected field descriptionsField Value Fixed or

VariableDescription

STRUCTURE CODE Integers Variable Identifier that defines the content andorder of the AMA record.

CALL CODE Integers Variable Indicates the call code. BellcoreFormat Automatic MessageAccounting Reference Guide,297-1001-830 , contains the currentcall codes for BCFMT office.

288 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 289: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

CALLING DN Symbolic text, up to18 digits

Variable Indicates calling number.

ORIG AGENT Symbolic text Variable Identifies the CLLI and circuit numberfor the originating circuit. Theoriginating agent can also be a line,identified by LEN and DN, attendantconsole, which is identified bycustomer group and console name, ora VFG identified by name andmember number.

CALLED DN Symbolic text, up to30 digits

Variable Identifies called number.

TERM AGENT Symbolic text Variable Identifies the CLLI and circuit numberfor the terminating circuit. This fieldcan also contain a line equipmentnumber (LEN) and a directory number(DN).

Active message exampleAMAB200 APR18 14:00:25 9200 INFO AMA TEST CALL RECORD

STRUCTURE CODE

CALLING DN

ORIG AGENT

CALLED DN

TERM AGENT

= 40510 CALL CODE = 006

= 1818104415

= CKT QNSX231PRUSE 5

= 800555121212345678912345678912

= LTD KNGA 431 DN 8114331 KEY 1

Clear message examplen/a

AMAB200 289

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 290: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AOSS100The Auxiliary Operator Services System (AOSS) subsystem generates thisreport when a data transmission error occurs during a digital modulator/demodulator (DMODEM or DM) to AOSS position or device connection,forcing the DMODEM to system busy (SysB).

Remedial actionPerform diagnostics on suspect trunk or DMODEM as indicated by troublecode. See Lines, Trunks, and Peripherals Trunks Alarms and PerformanceMonitoring Procedures 297-1001-585, and Lines, Trunks and PeripheralsCard Replacement Procedures 297-1001-589 for step-by-step trunkmaintenance procedures. See manufacturer''s manual for DMODEMmaintenance procedures. If these actions are ineffective, contact the nextlevel of maintenance.

AttributesAttribute Value

Severity Indeterminate

FormatAOSS100 mmmdd hh&gml.mm&gml.ss ssdd SYSB DM STATUS CHANGE

CKT trkid

DMODEM nnnn sttxt

Selected field descriptionsField Value Fixed or

VariableDescription

SYSB DM STATUSCHANGE

Constant Fixed Indicates status of DM has changed

CKT Symbolic text Variable Provides equipment identification forsuspect trunk equipment

DMODEM 0 to 9999 Variable Provides equipment identification forthe DMODEM

sttxt BREAK Variable Indicates communication betweenTraffic Operator Position System(TOPS) position, or device, andDMODEM has been lost

290 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 291: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

DS_NOT_READY Variable Indicates data set (DS) not ready,communication between DMODEMand TOPS position was not set up, orbroke down during transmission of amessage

sttxt FRAMING_ERROR Variable Indicates transmission line framingerror. Associated log reports will begenerated for excess of threshold

PARITY_ERROR Variable Indicates transmission line parityerror. Associated log reports will begenerated for excess of threshold

TERM_OVER_RUN Variable Indicates incoming character wasmissed by DMODEM

Active message exampleAOSS100 APR01 12:00:00 2112 SYSB DM STATUS CHANGE

CKT AOSSPOS 112

DMODEM 20 BREAK

Clear message examplen/a

Associated OM registers

AOSS101The Auxiliary Operator Services System (AOSS) subsystem generates thisreport when the reply from an AOSS device is not the expected reply,forcing the AOSS position to system busy (SysB).

Remedial actionPerform diagnostics on suspect trunk and return-to-service. See Trunks,Subsystem Alarm Analysis, Testing and Card Replacement,297-1001-501, for step-by-step trunk maintenance procedures. If theseactions are ineffective, contact the next level of maintenance.

AttributesAttribute Value

Severity Indeterminate

AOSS101 291

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 292: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FormatAOSS101 mmmdd hh:mm:ss ssdd SysB POS UNEXPECTED MESSAGE

DMODEM nnnn

CKT trkid

CLG = CKT trkid CLD = CKT trkid

hhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhh

Selected field descriptionsField Value Fixed or

VariableDescription

SysB POSUNEXPECTEDMESSAGE

Constant Fixed Indicates unexpected reply wasreceived from an AOSS device.

DMODEM nnnn 0-9999 Variable Provides equipment identification forthe digital modulator/ demodulator(DMODEM).

CKT trkid Symbolic text Variable Provides equipment identification forsuspect trunk equipment. See Table I.

CLG = CKT trkid Symbolic text Variable Identifies equipment used by callingparty. Absence of trkid indicatescalling party not connected. See TableI.

CLD = CKT trkid Symbolic text Variable Identifies equipment used by calledparty. Absence of trkid indicates calledparty not connected. See Table I.

hhhh 0000-FFFF Variable Displays 56 hexadecimal digits of theoffending message from the reportingcircuit.

Active message exampleAOSS101 APR01 12:00:00 2112 SysB POS UNEXPECTED MESSAGE

DMODEM 0

CKT AOSSPOS 112

CLG = CKT TERMBOX01 1 CLD = CKT TERMBOX03 1

0086B324B2D3B4B2BOBOBC1C5B2C3B8B2B4B14001B00011A1A138007

292 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 293: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

AOSS102The Auxiliary Operator Services System (AOSS) subsystem generates thisreport when an AOSS device sends the central control (CC) anunexpected message, forcing the AOSS device to system busy (SysB).

Remedial actionPerform diagnostics on suspect trunk and return to service. See Lines,Trunks, and Peripherals Trunks Alarms and Performance MonitoringProcedures 297-1001-585, and Lines, Trunks and Peripherals CardReplacement Procedures 297-1001-589 for step-by-step trunkmaintenance procedures. If these actions are ineffective, contact the nextlevel of maintenance.

AttributesAttribute Value

Severity Indeterminate

FormatAOSS102 mmmdd hh&gml.mm&gml.ss ssdd SYSB DEV

UNEXPECTED MESSAGE

CKT trkid

CKT trkid DMODEM nnnn

hhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhh

Selected field descriptionsField Value Fixed or

VariableDescription

SYSB DEVUNEXPECTEDMESSAGE

Constant Fixed Indicates unexpected message wasreceived from an AOSS device

CKT Symbolic text Variable Provides equipment identification forsuspect trunk equipment CKTSymbolic text Provides equipment

AOSS102 293

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 294: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

identification for trunk equipmentassociated with digital modulator/demodulator (DMODEM)

DMODEM 0 to 9999 Variable Provides equipment identification forthe DMODEM

hhhh 0000 to FFFF Variable Displays 56 hexadecimal digits of theoffending message from the reportingcircuit

Active message exampleAOSS101 APR01 12:00:00 2112 SYSB DEV UNEXPECTED MESSAGE

CKT TOPSDVE 2

CKT TOPSDEV 2 DMODEM 0

0086B324B2D3B4B2BOBOBC1C5B2C3B8B2B4B14001B00011A1A138007

Clear message examplen/a

Associated OM registers

AOSS103The Auxiliary Operator Services System (AOSS) subsystem generates thisreport when trouble is encountered during an AOSS call attempt, forcingthe AOSS position to system busy (SysB).

Remedial actionPerform diagnostics on suspect trunk or DM as indicated by trouble codeand return to service. See manufacturer''s manual for DM maintenanceprocedures. If these actions are ineffective, contact the next level ofmaintenance.

AttributesAttribute Value

Severity Indeterminate

FormatAOSS103 mmmdd hh&gml.mm&gml.ss ssdd SYSB AOSS TROUBLE

CKT trkid

294 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 295: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

TRBLCODE = trbtxt

Selected field descriptionsField Value Fixed or

VariableDescription

SYSB AOSSTROUBLE

Constant Fixed Indicates trouble was encounteredduring Traffic Operator PositionSystem (TOPS) call attempt

CKT Symbolic text Variable Provides equipment identification forsuspect trunk equipment

TRBLCODE CARRIER_LOST Variable Indicates communication betweenTOPS position and Digital Modulator/Demodulator (DM) broke down

CONFUSED_TERMINAL

Variable Indicates CONFUSION_MSG presenton data path

DATA_SET_NOT_READY

Variable Indicates no carrier from far end whengetting DM

TRBLCODE DATA_SET_TIMEOUT

Variable Indicates DM is not responding toconditioning

DM_DEADLOCK Variable Indicates DM has rejected outgoingmessage

INTEGRITY_FAILE D Variable Indicates integrity failed on data path

INTEGRITY_TIMEOUT

Variable Indicates bad connection to DMthrough network

SANITY_TIMEOUT Variable Indicates there was no reply toheadset query

STRANGE_MESSAGE

Variable Indicates an unexpected messagewas received from TOPS or DM

SUSPECT_OVERFLOW

Variable Indicates diagnostic run after suspectthreshold was exceeded

TERMINAL_OVERRUN

Variable Indicates incoming character missedby DM

Miscellaneous Variable Trouble is other than those listed

Active message exampleAOSS103 APR01 12:00:00 2112 SYSB AOSS TROUBLE

CKT AOSSPOS 212

TRBLCODE = CARRIER_LOST

AOSS103 295

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 296: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

AOSS105The Auxiliary Operator Services System (AOSS) subsystem generates thisreport when an operator at an AOSS position keys in a trouble code (TBL).The trouble code corresponds to a trouble condition which is eithercustomer reported or detected by the operator during the course of callprocessing. An operating company may define up to 100 trouble codes.These trouble codes are datafilled in customer data Table AOSSTRBL.When the AOSS position operator receives or detects a trouble condition,the operator keys in the one-or two-digit trouble code that corresponds tothe trouble condition. The AOSS105 is generated for non-maintenancerelated trouble conditions.

Remedial actionIdentify trouble condition from the trouble code, and take appropriateaction. If condition cannot be corrected, contact the next level ofmaintenance.

AttributesAttribute Value

Severity Indeterminate

FormatAOSS105 mmmdd hh:mm:ss ssdd TBL nn nnn nnn

CKT trkid CKT trkid

CLGNO = dn

CLDNO = dn

Selected field descriptionsField Value Fixed or

VariableDescription

TBL Constant Fixed Indicates trouble position for call

nn 00 to 99 Variable Indicates existing trouble condition.See customer data Table AOSSTRBL

nnn 000 to 999 Variable Indicates login identification ofoperator at AOSS position thatreported trouble condition

296 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 297: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

nnn 000 to 999 Variable Indicates position number of operatorthat reported trouble condition

CKT Symbolic text Variable Provides equipment identification fororiginating trunk equipment

CKT Symbolic text Variable Provides equipment identification forterminating trunk equipment

CLGNO Integers Variable Indicates calling number of customerwho reported trouble

CLDNO Integers Variable Indicates called number dialed bycustomer (or operator) on whichtrouble is detected

Active message exampleAOSS105 APR01 12:00:00 2112 TBL 5 212 3

CKT TERMBX01 1 CKT TERMBX03 1

CLGNO = 6132390123

CLDNO = 6138501234

Clear message examplen/a

Associated OM registers

AOSS107The Auxiliary Operator Services System (AOSS) subsystem generates thisreport when an operator at an AOSS position keys in a trouble code. Thetrouble code corresponds to a trouble condition which is either customerreported or detected by the operator during the course of call processing.An operating company may define up to 100 trouble codes. These troublecodes are datafilled in customer data Table AOSSTRBL, and are definedby the maintenance personnel and the AOSS force manager. When theAOSS position operator receives or detects a trouble condition, theoperator keys in the one or two-digit trouble code that corresponds to thetrouble condition. AOSS107 generates for maintenance related troubleconditions which are severe enough to generate a minor alarm.

Remedial actionIdentify trouble condition from the trouble code and take appropriate action.If condition cannot be corrected, contact the next level of maintenance.

AOSS107 297

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 298: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Minor

FormatAOSS107 mmmdd hh:mm:ss ssdd TBL MINOR ALARM nn nnn nnn

CKT trkid CKT trkid

CLGNO = dn

CLDNO = dn

Selected field descriptionsField Value Fixed or

VariableDescription

TBL MINOR ALARM Constant Fixed Indicates existing minor alarmcondition. See customer data TableAOSSTRBL

nn 00 to 99 Variable Indicates existing trouble condition.See customer data Table AOSSTRBL

nnn 000 to 999 Variable Indicates login identification ofoperator at AOSS position thatreported trouble condition

nnn 000 to 999 Variable Indicates position number of operatorthat reported trouble condition

CKT Symbolic text Variable Provides equipment identification fororiginating trunk equipment

CKT Symbolic text Variable Provides equipment identification forterminating trunk equipment

CLGNO Integers Variable Indicates calling number of customerwho reported trouble

CLDNO Integers Variable Indicates either called number dialedby customer or operator code

Active message exampleAOSS107 APR01 12:00:00 2112 TBL MINOR ALARM 5 212 3

CKT TERMBX01 1 CKT TERMBX03 1

CLGNO = 6132390123

CLDNO = 6138501234

298 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 299: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

AOSS108The Auxiliary Operator Services System (AOSS) subsystem generates thisreport when an operator at an AOSS position keys in a trouble code. Thetrouble code corresponds to a trouble condition which is either customerreported or detected by the operator during the course of call processing.An operating company may define up to 100 trouble codes. These troublecodes are datafilled in customer data Table AOSSTRBL, and are definedby the maintenance personnel and the AOSS force manager. When theAOSS position operator receives or detects a trouble condition, theoperator keys in the one-or two-digit trouble code that corresponds to thetrouble condition. AOSS108 is generated for maintenance-related troubleconditions which are severe enough to generate a major alarm.

Remedial actionIdentify trouble condition from the trouble code and take appropriate action.If condition cannot be corrected, contact the next level of maintenance.

AttributesAttribute Value

Severity Major

FormatAOSS108 mmmdd hh:mm:ss ssdd TBL MAJOR ALARM nn nnn nnn

CKT trkid CKT trkid

CLGNO = dn

CLDNO = dn

Selected field descriptionsField Value Fixed or

VariableDescription

TBL MAJOR ALARM Constant Fixed Indicates existing major alarmcondition

nn 00 to 99 Variable Indicates existing trouble condition.See customer data Table AOSSTRBL

AOSS108 299

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 300: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

nnn 000 to 999 Variable Indicates login identification ofoperator at AOSS position thatreported trouble condition

nnn 000 to 999 Variable Indicates position number of operatorthat reported trouble condition

CKT Symbolic text Variable Provides equipment identification fororiginating trunk equipment

CKT Symbolic text Variable Provides equipment identification forterminating trunk equipment

CLGNO Integers Variable Indicates calling number of customerwho reported trouble

CLDNO Integers Variable Indicates either called number dialedby customer or operator code

Active message exampleAOSS108 APR01 12:00:00 2112 TBL MAJOR ALARM 5 212 3

CKT TERMBX01 1 CKT TERMBX03 1

CLGNO = 6132390123

CLDNO = 6138501234

Clear message examplen/a

Associated OM registers

AP310This log is generated when the CPU test fails. The cardlist segmentprovides a cardlist associated with a trouble event.

Remedial actionReplace the indicated CPU card, and follow the standard card replacementprocedure. Run the test again manually from the CM MAP display. If thisfails to clear the problem, contact next level of maintenance.

AttributesAttribute Value

Severity Indeterminate

300 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 301: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FormatAP310 mmmdd hh:mm:ss ssdd TBL CPU Test Fault

Location: <node><card description>

Status: <trouble_status>

Trouble: <trouble_code

Action: <user_action>

The following tests failed:

<Test list>

Selected field descriptionsField Value Fixed or

VariableDescription

Test list Variable This field indicates the list of test thatfailed and that must be rerun afterreplacing the cards. Possible valuesinclude:

• Access protection RAM test

• Bus access test

• Data cache test

• FIR test

• MAU test

• Maze test

• Memory test for boot

• ROM checksum test

• RTIF test

• Static RAM test

• USART test

node FP n or AP n Variable This field indicates the supportoperating system (SOS) duplex nodethat failed the CPU test. The letter nindicates the number of the node inthe applicable inventory table.

card description alphanumeric Variable The field indicates a card within thenode. This card indicates the area ofthe node that failed testing, but may

AP310 301

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 302: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

not be the card actually at fault. Thefault card or cards are given by thecardlist in the body of the report

trouble_status Alarm raised Variable This field indicates the trouble status.This field is always "Alarm raised" forthis report.

user_action alpha Variable This field indicates an action for theoperating company personnel to take.

List of cards alphanumeric Variable This field indicates the list of cardsthat need to be replaced.

trouble_code Hardware test failed Variable This field indicates the trouble code.This field is always "Hardware testfailed" for this report.

Active message exampleAP310 SEP23 03:11:47 1479 TBL CPU Test Fault

Location: FP 0 CPU 1

Status: Alarm raised

Trouble: Hardware test failed

Action: Replace the following cards in the order list

The following tests failed:

---------------------------

ROM checksum test

Cardlist:

<List of cards>

Clear message examplen/a

Associated OM registers

AP311This log is generated when there is a fault with a memory card in the node.The cardlist segment provides a cardlist associated with a trouble event.

302 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 303: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionPerform the action stated in the user action field. If a memory test failed,replace the card as soon as possible because all reads from the faultyaddress will fail.

AttributesAttribute Value

Severity Minor

Format<alrm>AP311 mmmdd hh:mm:ss ssdd TBL Memory Test Fault

Location: <node><card description>

Status: <trouble_status>

Trouble: <trouble_code>

Action: <user_action>

Test Failed Return Code

-------------------- --------------------

<test><result>

Selected field descriptionsField Value Fixed or

VariableDescription

alrm * Variable This field indicates a minor alarm forthis event; otherwise, no alarmdisplays.

node FP n or AP n Variable This field indicates the supportoperating system (SOS) duplex nodethat failed the memory test. The lettern indicates the number of the node inthe applicable inventory table.

card description alphanumeric Variable This field indicates a card within thenode. The card indicates the area ofthe node that failed testing, but maynot be the card actually at fault. Thefaulty card or cards are given by thecardlist in the body of the report.

AP311 303

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 304: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

trouble_status Alarm raised Variable This field indicates the trouble status.This field is always "Alarm raised" forthis report.

trouble_code alpha Variable This field indicates nature of theproblem being reported.

user_action alpha Variable This field indicates the actionoperating company personnel shouldtake.

test alpha Variable This field indicates which test thememory component failed, or couldnot be completed.

result alpha Variable This field indicates the test results.

List of cards alphanumeric Variable This field indicates the list of cards tobe replaced.

Active message example*AP311 SEP02 12:34:10 2351 TBL Memory Test Fault

Location: FP 0 Plane 1 Memory Card 3

Status : Alarm raised

Trouble: Hardware test failed

Action: Replace the following cards in the order listed

Test Failed Return Code

----------- -----------

Memory match Failed

Cardlist:

Site Flr RPos Bay_id Shf Description Slot EqPEC Side

---- -------- ------ --- ----------- ---- ----- ----

HOST 01 D00 FP:00 03 Mem 08 9X14DA

Clear message examplen/a

304 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 305: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AP313This log is generated when there is a fault with the syncing of a processor.

Remedial actionCheck failure reason. Check faulty cards. Run the test again manually fromthe CM MAP display. If the test fails to clear the problem, contact the nextlevel of maintenance.

AttributesAttribute Value

Severity Major

Format<alrm>AP313 mmmdd hh:mm:ss ssdd TBL Fault Sync

Location: <node>

Status: <trouble_status>

Trouble: <trouble_code>

Action: <user_action>

Detailed Reason: <reason_text>

Cardlist:

<List of cards>

Selected field descriptionsField Value Fixed or

VariableDescription

alrm ** Variable This field indicates the alarm for thisevent. This field always indicates amajor alarm.

node FP n or AP n Variable This field indicates the supportoperating system (SOS) duplex nodethat lost synchronization. The letter nindicates the number of the node inthe applicable inventory table.

AP313 305

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 306: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

trouble_status Alarm raised Variable This field indicates the trouble status.This field is always "Alarm raised" forthis report.

trouble_code alpha Variable This field indicates the nature of theproblem being reported.

user_action alpha Variable This field indicates the action to take.

reason_text alpha Variable This field indicates the reason forfailure to synchronize.

List of cards alphanumeric Variable This field indicates the list of cardsthat may require replacing.

Active message example**AP313 SEP02 12:34:10 2351 TBL Fault Sync

Location: FP 0

Status: Alarm raised

Trouble: HW test failed

Action: Replace the following cards in the order listed

Detailed reason:

Mate memory missing

Cardlist:

Site Flr RPos Bay_id Shf Description Slot EqPEC Side

---- --- ---- ------ --- ----------- ---- ----- ----

HOST 01 D00 FP:00 03 Mem 08 9X14DA

Clear message examplen/a

Associated OM registers

AP314This log is generated when there is a problem with the switch of activity(SWACT) of a processor.

306 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 307: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionCheck failure reason. Check faulty cards from cardlist. Run the test againmanually from the CM MAP display. If this fails to clear the problem,contact the next level of maintenance.

AttributesAttribute Value

Severity Major

Format<alrm>AP314 mmmdd hh:mm:ss ssdd TBL SwAct Fault

Location: <node>

Status: <trouble_status>

Trouble: <trouble_code>

Action: <user_action>

Detailed Reason <reason_text>

Cardlist:

<List of cards>

Selected field descriptionsField Value Fixed or

VariableDescription

alrm ** Variable This field indicates the alarm for thisevent. This field always indicates amajor alarm.

node FP n or AP n Variable This field indicates the supportoperating system (SOS) duplex nodethat failed to switch activity. The lettern indicates the number of the node inthe applicable inventory table.

trouble status Alarm raised Variable This field indicates the status for thisevent. This field is always "Alarmraised" for this event.

trouble code alpha Variable This field indicates the nature of theproblem being reported.

user_action alpha Variable This field indicates the action to take.

AP314 307

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 308: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

reason_text alpha Variable This field indicates the reason forfailure to switch activity.

List of cards alphanumeric Variable This field indicates the list of cardsthat may require replacing.

Active message example**AP314 SEP02 12:34:10 2351 TBL SwAct Fault

Location: FP 0

Status: Alarm raised

Trouble: Hardware test failed

Action: Replace the following cards in the order listed

Detailed Reason: SwAct failed, mate was jammed

Cardlist:

Site Flr RPos Bay_id Shf Description Slot EqPECSide

---- --- ---- ------ --- ----------- ---- ---------

HOST 01 D00 FP:00 03 Mem 08 9X14DA

Clear message examplen/a

Associated OM registers

AP315This log is generated when there is a fault with the jamming of a processor.

Remedial actionCheck failure reason. Check faulty cards from cardlist. Try to jam the matemanually. If this fails to clear the problem, contact the next level ofmaintenance.

AttributesAttribute Value

Severity Minor

308 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 309: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Format<alrm>AP315 mmmdd hh:mm:ss ssdd TBL Jam Fault

Location: <node>

Status: <trouble_status>

Trouble: <trouble_code>

Action: <user_action>

Detailed reason: <reason_text>

Cardlist:

<List of cards>

Selected field descriptionsField Value Fixed or

VariableDescription

alrm * Variable This field indicates the alarm for theevent. This field always indicates aminor alarm for this event.

node FP n or AP n Variable This field indicates the supportoperating system (SOS) duplex nodethat is reporting the jam fault. Theletter n indicates the number of thenode in the applicable inventory table.

trouble_status Alarm raised Variable This field indicates the trouble status.This field is always "Alarm raised" forthis report.

trouble_code alpha Variable This field indicates the nature of theproblem being reported.

user_action alpha Variable This field indicates the action to take.

reason_text alpha Variable This field indicates the reason forfailure of the jam attempt.

List of cards alphanumeric Variable This field indicates the list of cardsthat may require replacing.

Active message example*AP315 SEP02 12:34:10 2351 TBL Jam Fault

Location: FP 0

Status: Alarm raised

AP315 309

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 310: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Trouble: Hardware test failed

Action: Replace the following cards in the order listed

Detailed reason:

Could not write character to RTIF

Cardlist:

Site Flr RPos Bay_id Shf Description Slot EqPECSide

---- --- ---- ------ --- ----------- ---- ---------

HOST 01 D00 FP:00 03 RTIF 08 9X21BA

Clear message examplen/a

Associated OM registers

AP316This log is generated when the image test of a CPU fails.

Remedial actionContact the next level of maintenance. In the meantime, use the last loadthat ran successfully through an image test.

AttributesAttribute Value

Severity Major

Format<alrm>AP316 mmmdd hh:mm:ss ssdd TBL Image Test Fail

Location: <node>

Status: <trouble_status>

Trouble: <trouble_code>

Action: <user_action>

Detailed reason <reason_text>

310 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 311: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

alrm ** Variable This field indicates the alarm for thisevent. This field always indicates amajor alarm.

node FP n or AP n Variable This field indicates the supportoperating system (SOS) duplex nodethat failed the image test. The letter nindicates the number of the node inthe applicable inventory table.

trouble status alpha Variable This field indicates the trouble status.This field is always "Alarm raised" forthis report.

trouble_code alpha Variable This field indicates the nature of theproblem being reported. This fieldalways indicates "Software error,location unknown" for this report.

user_action alpha Variable This field indicates the action to take.

reason_text alpha Variable This field indicates the reason forfailure for the image test. This fieldalways indicates "Image test failed" forthis report.

Active message example** AP316 SEP02 12:34:10 2351 TBL Image Test Fail

Location: FP 0

Status: Alarm raised

Trouble: Software error, location unknown

Action: Report to higher level mtc

Detailed reason: Image test failed

Clear message examplen/a

Associated OM registers

AP319This log is generated when there is a discrepancy between the datafill forthe node and hardware present.

AP319 311

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 312: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionCheck datafill. Manually update the datafill.

AttributesAttribute Value

Severity Major

Format<alrm>AP319 mmmdd hh:mm:ss ssdd TBL Hardware Datafill Fault

Location: <node>

Status: <trouble_status>

Trouble: <trouble_code>

Action: <user_action>

Cardlist:

<List of cards>

Selected field descriptionsField Value Fixed or

VariableDescription

alrm ** Variable This field indicates the alarm for thisevent. This field always indicates amajor alarm for this report.

node FP n or AP n Variable This field indicates the supportoperating system (SOS) duplex nodethat has the datafill discrepancy. Theletter n indicates the number of nodein the applicable inventory table.

trouble_ status alpha Variable This field indicates the trouble status.This field is always "Alarm raised" forthis report.

trouble_code alpha Variable This field indicates the nature of theproblem being reported.

user_action alpha Variable This field indicates the action to take.

List of cards alphanumeric Variable This field indicates the cards involved.If both hardware and datafill arepresent, the cardlist contains twoentries. The first is the card identityaccording to datafill. The second is the

312 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 313: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

card identity actually found. If theproblem is missing hardware ormissing datafill, the cardlist contains asingle entry that describes what isactually present.

Active message example** AP319 SEP02 12:34:10 2351 TBL Hardware Datafill Fault

Location: FP 0

Status: Alarm raised

Trouble: Datafill missing

Action: Check datafill and correct if necessary

Cardlist:

Site Flr RPos Bay_id Shf Description Slot EqPECSide

---- --- ---- ------ --- ----------- ---- ---------

HOST 01 D00 FP:00 03 Mem 08 9X14DA

Clear message examplen/a

Associated OM registers

AP320This log is generated whenever a trap occurs. Traps occur either on anactive CPU running in simplex mode, or on both CPUs when they arerunning in sync.

Before contacting the next level of maintenance, obtain additional trapinformation by entering TRAPESTFO at CI MAP level. This informationincludes all local variables and parameters on the stack when the trapoccurred. Save all reports generated during the five minutes before thetrap report and the information obtained after entering the TRAPINFOcommand.

Remedial actionContact the next level of maintenance.

AP320 313

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 314: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatAP320 mmmdd hh:mm:ss ssdd TBL Software Trap

Location: <node>

Status: <trouble_status>

Trouble <trouble_code>

Action: <user_action>

Trap number: <nn>, <reason>

Selected field descriptionsField Value Fixed or

VariableDescription

node FP n or AP n Variable This field indicates the supportoperating system (SOS) duplex nodewhere the trap occurs. The letter nindicates the number of the node inthe applicable inventory table.

trouble_status alpha Variable This field indicates the trouble status.This field is always "Trouble alert" forthis report.

trouble_code alpha Variable This field indicates the nature of theproblem being reported. This field isalways "Application software error" forthis report.

user_action alpha Variable This field indicates the action to take.This field always indicates "Pleaseforward this report to higher-levelmaintenance" for this report.

nn numeric Variable This field indicates the cumulativenumber of traps on the reportingprocessor since the last restart.

reason alphanumeric Variable This field indicates the cause of thetrap.

Active message exampleAP320 SEP02 12:34:10 2351 TBL Software Trap

314 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 315: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Location: FP 0

Status: Trouble alert

Trouble: Application SW error

Action: Please forward this report to higher-level 1

Trap number: 2, Zero divide

Clear message examplen/a

Associated OM registers

AP321This log is generated when the amount of unused memory in the node hasfallen below safe levels.

Remedial actionReview resource provisioning. If necessary, perform a memory extension.Contact next level of maintenance for this analysis.

AttributesAttribute Value

Severity • Warning

• Minor

Format<alrm>AP321 mmmdd hh:mm:ss ssdd TBL Low Resource Warning

Location: <node>

Status: <trouble_status>

Trouble: <trouble_code>

Action: <user_action>

<kwds>KWORDS OF MEMORY LEFT.

AP321 315

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 316: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Field Value Variable Description

alrm * Variable This field indicates the alarm for theevent. This field always indicates aminor alarm for this report.

node FP n or AP n Variable This field indicates support operatingsystem (SOS) duplex node that hasthe low memory warning. The letter nindicates the number of the node inthe applicable inventory table.

trouble_status Alarm raised Variable This field indicates the trouble status.This field is always "Alarm raised" forthis report.

trouble_code alpha Variable This field indicates the nature of theproblem being reported. This field isalways "Low memory" for this report.

user_action alpha Variable This field indicates the action to take.This field is always "Review resourceprovisioning" for this report.

kwds Integer Variable This field indicates the number ofkilowords of remaining availabledatastore.

Active message example* AP321 SEP02 12:34:10 2351 TBL Low Resource Warning

Location: FP 0

Status: Alarm raised

Trouble: Low memory

Action: Review resource provisioning

Clear message examplen/a

Associated OM registers

AP322This log is generated when the spare memory allocation in the node isbeing depleted.

316 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 317: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionRepair or replace faulty memory cards.

AttributesAttribute Value

Severity • Warning

• Minor

Format<alrm>AP322 mmmdd hh:mm:ss ssdd TBL Low Spare Warning

Location: <node>

Status: <trouble_status>

Trouble: <trouble_code>

Action: <user_action>

CPU <p>is running out of available spares.

CPU <p>has <n>2MByte spare(s) remaining.

<n>8MByte spare(s) remaining.

Selected field descriptionsField Value Fixed or

VariableDescription

node FP n or AP n Variable This field indicates the supportoperating system (SOS) duplex nodethat has a low memory warning. Theletter n indicates the number of thenode in the applicable inventory table.

trouble_status Alarm raised Variable This field indicates the trouble status.This field always indicates "Alarmraised" for this report.

trouble_code Low memory Variable This field indicates the nature of theproblem being reported. This fieldalways indicates "Low memory" forthis report.

user_action alpha Variable This field indicates the action to take.

AP322 317

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 318: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

p numeric Variable This field indicates the plane of thenode on which the number of sparememory modules available has fallenbelow safe levels.

n numeric Variable The field indicates the count of sparemodules of a given size remaining forsubstitution.

Variable Fields p and n repeat if the node isrunning in synchronous mode ofoperation.

alrm * Variable This field indicates the alarm for theevent. This field always indicates aminor alarm for this report.

Active message example* AP322 SEP02 12:34:10 2351 TBL Low Spare Warning

Location: FP 0

Status: Alarm raised

Trouble: Low memory

Action Review resource provisioning

CPU 0 is running out of available spares.

CPU 0 2 2MByte spare (s) remaining.

0 8MByte spare(s) remaining.

Clear message examplen/a

Associated OM registers

AP323This log is generated when the REx test fails. The cardlist segmentprovides a cardlist associated with a trouble event.

318 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 319: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionReplace the indicated card using the card replacement procedure. Run thetest again manually from the CM MAP display. If this fails to clear theproblem, contact the next level of maintenance.

AttributesAttribute Value

Severity Major

Format<alrm>AP323 mmmdd hh:mm:ss ssdd TBL FAIL REX TEST

Location: <node>

Status: <trouble_status>

Trouble: <trouble_code>

Action: <user_action>

FORMAT 1.

<action><cntxtl><cntxt2><rextype>TEST FAILED.

FAILED TEST : <test_name>

FAIL PATTERN : <bit_pattern>

Cardlist:

<List of cards>

FORMAT 2.

<reason>

AP323 319

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 320: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

alrm ** Variable This field indicates the alarm for theevent. This field always indicates amajor alarm for this report.

node FP n or AP n Variable This field indicates the supportoperating system (SOS) duplex nodethat failed the CPU test. The letter nindicates the number of the node forthe applicable inventory table.

trouble_status Alarm raised Variable This field indicates the trouble status.This field is always "Alarm raised" forthis report.

trouble_code REx test failed Variable This field indicates the nature of theproblem being reported. This fieldalways indicates "REx test failed" forthis report.

user_action Replace the followingcards in the orderlisted

Variable This field indicates the action to take.This field always indicates "Replacethe following cards in the order listed"for this report.

action Manual or System Variable This field indicates if the test wasrequested from the MAP terminal orby the system.

cntxt1 Short or Long Variable This field indicates if the test was ashort one of a long (more exhaustive)one.

cntxt2 Simplex or Duplex Variable This field indicates the mode theapplication processor was in when thetest ran. Simplex means the node wasout of sync. Duplex means the nodewas operating in sync.

rextype CPU or MEM Variable This field indicates which set of testsran and detected a fault.

reason alpha Variable This field indicates the reason for theREx failure.

test_name alpha Variable This field indicates the test thatdetected the fault.

bit_pattern binary Variable This field indicates the 16-bit binaryvalue. Each bit set indicates whichsteps in the test failed.

320 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 321: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message example** AP323 SEP02 12:34:10 2351 TBL FAIL REX TEST

Location: FP 0

tatus: Alarm raised

Trouble: REx test failed

Action: Replace the following cards in the order listedManual Long Duplex CPU Failed.

FAILED TEST : ACT_GO_INACT

FAIL PATTERN : 0001

Cardlist:

<List of cards>

Clear message examplen/a

Associated OM registers

AP324The Application Processor (AP) generates log report AP324 in the event ofa peripheral interrupt mismatch. The system generates this report whenthe Application Processor /File Processor runs in sync and only oneprocessor receives the peripheral interrupt. The arrival of the peripheralinterrupt notifies the processors of the message.

Remedial actionReplace the indicated card(s). Follow the procedure for standard cardreplacement. Run a manual test on each card in the cardlist. Oncompletion of successful card test(s), synchronize the node again. If any ofthe tests fail, contact the next level of maintenance.

AttributesAttribute Value

Severity Indeterminate

Format1.AP324 <mmmdd><hh:ss:ss:><ssdd>TBL Peripheral Interrupt

AP324 321

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 322: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Received

Location: <AP/FP>

Status: <statext>

Trouble <Tblxt>

Action: <actxt>

Cardlist:

Site Flr RPos Bay_id Shf Description Slot EqPEC Side

------ ---- ------ ---------- ------ ---------------------------- ---------- ------

...................<cardlistdata>..................

Selected field descriptionsField Value Fixed or

VariableDescription

TBL PeripheralInterrupt Received

Constant Fixed Indicates that only one processorreceives the Peripheral Interrupt

Location < AP/FP > < 0..99 > Variable Specifies the correct node for whichthe system generates this log

Status Alarm raised Variable Indicates why the system generatesthis log

Trouble Bus fault, Transientfault, Hardware testfails

Variable Indicates which type of peripheralinterrupt mismatch occurs

Active message exampleAP324 JUN25 07:33:58 3600 TBL Peripheral Interrupt Received

Location: FP 2

Status: Alarm raised

Trouble: Bus fault

Action: Replace the following cards in the order listed

Peripheral interrupt received, sync dropped by the mismatch.

Manual action required to re-synchronize the CPUs. Cardlist:

322 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 323: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Site Flr RPos Bay_id Shf Description Slot EqPEC

Side - - - - - - - - - - - - - - - - - -- --

- - - HOST 01 00 FP:02 03 Port 15

9X86AA FRNT HOST 01 00 FP:02 03 Port

15 9X86AA FRNT

Clear message examplen/a

Associated OM registers

AP401The Application Processor generates this report once a day at 9:00 toprovide a summary of the number of status checks for the node.

Remedial actionThis log is an information log and requires no immediate action.

AttributesAttribute Value

Severity Warning

FormatFP401 mmmdd hh:mm:ss ssdd INFO Duplex Node Daily Summary

Location: <node>

Checksum Ran to Completion :nnn Times

Traps in Last 24 Hours: nnnnn

CARD FAULTS

CPU0 CPU1

CARD TRANSIENT CARD TRANSIENT

ERRORS ERRORS

0 n 0 n

1 . 1 n

AP401 323

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 324: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

. . . .

. . . .

m n m n

Selected field descriptionsField Value Fixed or

VariableDescription

node 0-99 Variable This field specifies the node for whichthis log is generated.

Active message exampleAP401 SEP02 12:34:10 2351 INFO Duplex Node Daily Summary

Location: FP 0

Checksum Ran to Completion ;22 Times

Traps in Last 24 Hours: 1

CARD Faults

CPU0 CPU1

CARD TRANSIENT CARD TRANSIENT

ERRORS ERRORS

3 1 8 1

4 2

Clear message examplen/a

Associated OM registers

AP450The Application Processor (AP) generates log report AP450 to summarizea series of event reports under one log header. The event reports occurduring the routine exercise (REX) test.

The timestamp on the AP450 header line represents when the report issubmitted to the central log system for output. The timestamps on theseparate event header lines are the local lines assigned to the separate

324 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 325: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

events at the reporting nodes. The system assigns the local lines when theevents first generate. The time on the AP450 header line is normally 10and 20 s after the time of the last reported event.

The AP450 is never alarmed. The AP450 is for the user to read and use asan abbreviated summary of a routine series of operations. Examples ofthese operations are the operations that compose an REX test.

The <entity name> is the text name of a hardware or software componentor a service. The <entity name> can also be the text name of some otherentity that associates with the switch. The <detailed event type> is adescriptive phase. This phase describes the type of trouble, state change,operation, or other type of event that occurs and involves a given entity. Allof the events of state changes and all of the faults are also reported asseparate logs. This reporting makes these events and faults readilyaccessible to mechanized downstream analysis.

The system logs high-priority events when they reach the central logsystem. Reporting applications identify high-priority events. The systemlogs other events after the generation of the AP450 summary report.Events AP450 report, and never as separate logs.

Remedial actionThe use of the AP450 message is to aid in log analysis. This messagebrings together related events in one report, in their correct time sequence.The action required depends on the characteristics of the events reported.

AttributesAttribute Value

Severity Warning

Format1.Officeid AP450 mmmdd hh:mm:ss ssdd INFO REX Test Summary

Location: <entity name>

Summary: REX Test REX Successful

AP450 325

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 326: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFO REX TestSummary

CONSTANT Variable Indicates the generation of highpriority events for a single log report.

Location Character string Variable Indicates the test name of a hardwareor software component, a service, orsome other entity that associates withthe switch.

Summary Description text Variable Indicates a phase describing whatkind of trouble, state change,operation, or other types ofoccurrences that inolove the givingentity.

Active message exampleESCP AP450 JUN20 17:31:05 8591 INFO REX Test Summary

Location: AP 7

Summary: REX Test Sequence Successful

Clear message examplen/a

Associated OM registers

AP450 Format 2The Application Processor (AP) generates log report AP450 to summarizea series of event reports under one log header. The event reports occurduring the routine exercise (REX) test.

The timestamp on the AP450 header line represents when the report issubmitted to the central log system for output. The timestamps on theseparate event header lines are the local lines assigned to the separateevents at the reporting nodes. The system assigns the local lines when theevents first generate. The time on the AP450 header line is normally 10and 20 s after the time of the last reported event.

The AP450 is never alarmed. The AP450 is for the user to read and use asan abbreviated summary of a routine series of operations. Examples ofthese operations are the operations that compose an REX test.

326 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 327: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The <entity name> is the text name of a hardware or software componentor a service. The <entity name> can also be the text name of some otherentity that associates with the switch. The <detailed event type> is adescriptive phase. This phase describes the type of trouble, state change,operation, or other type of event that occurs and involves a given entity. Allof the events of state changes and all of the faults are also reported asseparate logs. This reporting makes these events and faults readilyaccessible to mechanized downstream analysis.

The system logs high-priority events when they reach the central logsystem. Reporting applications identify high-priority events. The systemlogs other events after the generation of the AP450 summary report.Events AP450 report, and never as separate logs.

Remedial actionThe use of the AP450 message is to aid in log analysis. This messagebrings together related events in one report, in their correct time sequence.The action required depends on the characteristics of the events reported.

AttributesAttribute Value

Severity Warning

Format1.Officeid AP450 mmmdd hh:mm:ss ssdd INFO REX Test Summary

Location: <entity name>

Summary: REX Test Sequence Failed

TIME EVENT

___ ____

hh:mm:ss <detailed event type>

......................

hh:mm:ss <detailed event type>

AP450 Format 2 327

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 328: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFO REX TestSummary

CONSTANT Variable Indicates the generation of highpriority events for a single log report.

Location Character string Variable Indicates the test name of a hardwareor software component, a service, orsome other entity that associates withthe switch.

Summary Description text Variable Indicates a phase describing whatkind of trouble, state change,operation, or other types ofoccurrences that involve the givingentity.

Active message exampleESCP AP450 JUN20 17:31:05 8591 INFO REX Test Summary

Location: AP 7

Summary: REX Test Sequence Failed

TIME EVENT

---- ----

16:48:43 Initiate Rex

16:50:13 Initiate Cpu Test

16:51:06 REx Fault

16:51:06 Initiate Sync

16:51:10 Initiate Cpu Test

16:51:23 Initiate Memory Test

16:52:43 Initiate Memory Test

16:54:03 Initiate Memory Test

16:55:23 Initiate Memory Test

16:57:19 Initiate Memory Test

328 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 329: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Action: look for AP323 log(s)

Clear message examplen/a

Associated OM registers

AP451The Application Processor (AP) generates log report AP451 in order tocontinue the summary that the AP450 report began. The system generatesAP451 when a single log report cannot fit all the information that mustpass. The system generates as many additional AP451 reports as requiredto complete event summary.

Remedial actionThe use of the AP450 message is to aid in log analysis. This messagebrings together related events in one report, in their correct time sequence.The required action depends upon the characteristics of the eventsreported.

AttributesAttribute Value

Severity Warning

Format1.OFFICEID AP451 mmmdd hh:mm:ss ssdd INFO REX TEST SUMMARY(contd)

Location: <entity name>

Summary: REX Test Sequence Failed

TIME EVENT

------ --------

hh:mm:ss <detailed event type>

....................

hh:mm:ss <detailed event type>

AP451 329

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 330: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFO REX TESTSUMMARY

Variable Indicates the generation of thesummary that an AP450 log reportbegins when more information isrequired.

Summary Variable Indicates a phase that describes thetype of trouble, state change,operation, or other type of event thatoccurs. These conditions and eventsmust involve the given entity.

Active message example1.ESCP AP451 JUN20 17:31:05 8591 INFO REX TEST SUMMARY

(contd)

Location: AP 7

Summary: REX Test Sequence Successful

1.ESCP AP450 JUN20 17:31:05 8591 INFO REX TEST SUMMARY(contd)

Location: AP7

Summary: REX Test Sequence Failed

TIME EVENT

---- -----

16:48:43 Initiate Rex

16:50:13 Initiate Cpu Test

16:51:06 REx Fault

16:51:06 Initiate Sync

16:51:10 Initiate Cpu Test

16:51:23 Initiate Memory Test

16:52:43 Initiate Memory Test

330 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 331: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

16:54:03 Initiate MemoryTest

16:55:23 Initiate Memory Test

16:57:19 Initiate Memory Test

Clear message examplen/a

Associated OM registers

AP501The log is generated when the activity state of a processor changes.

If a trouble condition exists, the DMS-250 switch generates other logreports that indicate the nature of the problem.

Remedial actionThis log is an information only log and requires no immediate action.

AttributesAttribute Value

Severity Warning

FormatAP501 mmmdd hh:mm:ss ssdd INFO Activity State Change

Location: <node>

REASON: <change reason>

FROM: <sync_state><jam_state>Side <p>Active

TO: <sync_state><jam_state>Side <q>Active

Selected field descriptionsField Value Fixed or

VariableDescription

Field Value Variable Description

node 0-99 Variable This field specifies the supportoperating system (SOS) duplex nodefor the processor that had a statechange.

AP501 331

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 332: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

change reason Unknown cause,Manual command,System detectedchange, trouble,Scheduled test,Change of state ofassociated entity,System initiatedrecovery

Variable This field indicates the reason for thestate change.

sync_state In sync, Not in sync Variable This field indicates thesynchronization status of the nodebefore and after the state change.

jam_status Jammed, Jamreleased

Variable This field indicates the jam status ofthe node before and after the statechange.

p numeric Variable This field indicates the activeprocessor before and after the statechange.

q numeric Variable This field indicates the activeprocessor before and after the statechange.

Active message exampleAP503 SEP02 12:34:10 2351 INFO Activity State Change

Location: FP 0

REASON: Manual command

FROM: In sync Jam released Side 0 Active

TO: In sync Jam released Side 1 Active

Clear message examplen/a

Associated OM registers

AP502This log is generated when there is a change in the status of a processor,memory, or port circuit pack in a duplex file processor or applicationprocessor. When a change in processor card state is reported, twosuccessive AP502 logs are generated, one for each plane of the node.

332 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 333: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

If a trouble condition exits, the DMS-250 switch generates other log reportsthat indicate the nature of the problem.

Remedial actionThis is an information log and requires no immediate action.

AttributesAttribute Value

Severity • Warning

• Critical

FormatAP502 mmmdd hh:mm:ss ssdd INFO Card State Change

Location: <card description>

REASON: <change reason>

FROM: <state>

TO: <state>

<Opt component state list>

AP502 333

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 334: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

card_description alphanumeric Variable This field provides the location of anapplication processor or file processorcard, memory card, or port card. If thelocation is a processor card, the statechange reported on the FROM andTO lines is the computed status forthe processor as a whole. The statusof the individual cards making up theprocessor is reported in the < Optcomponent state list > field at the endof the log. If the location is a memorycard, the state change reported is forthat specific card. If the location is aport card, the < Opt component statelist > at the end of the log displays thestate of the port card component thatcaused the card to change state.

change reason Unknown cause,Manual command,System detectedtrouble, Scheduledtest, Change of stateof associated entity,System initiatedrecovery

Variable This field indicates the cause of thestate change.

state Under test, Split,Faulty, Dependency,In service trouble,Hardware not tested,Unequipped, REX,Clock fault, E2A fault,Okay

Variable This field indicates the computed stateof the processor as a whole, or thestate of the memory card before andafter the state change.

Opt component statelist

Fault cleared, Devicein ISTb condition, Noncritical virtual port 0ISTb trap, Non criticalvirtual port 1 ISTbtrap, Non criticalvirtual port 0 ISTBtest, Non criticalvirtual port 1 ISTbtest, Link 0 is out ofservice, Link 1 is outof service, Both linksare out of service,

Variable This field displays only if the FROMand TO lines are not in the REX orUnder test states. For a processorcard, the values this field displays arethe same as in the state field.Otherwise, the values in this fielddisplay the port card state.

334 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 335: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Node is split, Criticaltrap fault, Critical testfault, Text unavailable

Active message exampleAP502 SEP02 12:34:10 2351 INFO Card State Change

Location FP 0 CPU 1

REASON: System detected trouble

FROM: Okay

TO: In service trouble

CARD TYPE OLD STATE NEW STATE

--------- --------- ---------

Processor Okay Okay

Power Okay Okay

Bus Term Okay Okay

RTIF Okay Okay

AP502 OCT22 09:18:36 1000 INFO Card State Change

Location FP 0 Plane 0 Port Card 0

REASON: System detected trouble

FROM: Okay

TO: In service trouble

Detailed reason: Link 1 is out of service

Clear message examplen/a

AP502 335

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 336: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AP503This log is generated when the synchronization state of the node changes.

If a trouble condition exists, the DMS-250 switch generates other logreports that indicate the nature of the problem.

Remedial actionThis is an information log and requires no immediate action.

AttributesAttribute Value

Severity Warning

FormatAP503 mmmdd hh:mm:ss ssdd INFO Sync State Change

Location: <node>

REASON: <change reason>

FROM: <sync_state><jam_state>Side <p>Active

TO: <sync_state><jam_state>Side <q>Active

Selected field descriptionsField Value Fixed or

VariableDescription

node FP n or AP n Variable This field indicates the supportoperating system (SOS) duplex nodewhere n is the number of the node inthe applicable inventory table.

change reason Unknown cause,Manual command,System detectedtrouble, Scheduledtest, Change of stateof associated entity,System initiatedrecovery

Variable This field indicates the cause of thechange.

sync_state In sync, Not in sync Variable This field indicates thesynchronization status of the nodebefore and after the state change.

336 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 337: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

jam_state Jammed, Jamreleased

Variable This field indicates the jam status ofthe node before and after the statechange.

p numeric Variable This field indicates the activeprocessor before and after the statechange.

q numeric Variable This field indicates the activeprocessor before and after the statechange.

Active message exampleAP503 SEP02 12:34:10 2351 INFO Sync State Change

Location: FP 0

REASON: Manual command

FROM: In sync Jammed Side 0 Active

TO: Not in sync Jammed Side 0 Active

Clear message examplen/a

Associated OM registers

AP504This log is generated when the jam state of the node changes.

If a trouble condition exists, the DMS-250 switch generates other logreports that indicate the nature of the problem.

Remedial actionThis log is an information log and requires no immediate action.

AttributesAttribute Value

Severity Warning

FormatAP504 mmmdd hh:mm:ss ssdd INFO Jam State Change

AP504 337

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 338: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Location: <node>

REASON: <change reason>

FROM: <sync_state><jam_state>Side <p>Active

TO: <sync_state><jam_state>Side <q>Active

Selected field descriptionsField Value Fixed or

VariableDescription

node FP n or AP n Variable This field indicates the supportoperating system (SOS) duplex nodewhere n is the number of the node inthe applicable inventory table.

change reason Unknown cause,Manual command,System detectedtrouble, Scheduledtest, Change of stateof associated entity,System initiatedrecovery

Variable This field indicates the cause of thestate change.

sync_state In sync, Not in sync Variable This field indicates thesynchronization status of the nodebefore and after the state change.

jam_state Jammed, Jamreleased

Variable This field indicates the jam status ofthe node before and after the statechange.

p numeric Variable This field indicates the activeprocessor before and after the statechange.

q numeric Variable This field indicates the activeprocessor before and after the statechange.

Active message exampleAP504 SEP02 12:34:10 2351 INFO Jam State Change

Location: FP 0

REASON: Manual command

FROM: Not in sync Jammed Side 0 Active

TO: Not in sync Jam released Side 0 Active

338 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 339: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

AP800The application processor generates this report when the node isexperiencing a high trap rate.

Remedial actionIf the problem persists, contact next level of maintenance.

AttributesAttribute Value

Severity Minor

Format<alrm>AP800 mmmdd hh:mm:ss ssdd TBL HIGH TRAP RATE

Location: <node>

nnnn Traps per Minute

Selected field descriptionsField Value Fixed or

VariableDescription

alrm * Variable This field indicates the alarm for thisevent. This field always indicates aminor alarm for this report.

node AP n Variable This field indicates the supportoperating system (SOS) duplex nodefor the event. The letter n indicates thenode of number for the applicableinventory table.

nnnn numeric Variable This field indicates the number oftimes the high trap rate occurs

Active message example* AP800 SEP05 18:14:33 4827 TBL HIGH TRAP RATE

Location: FP 0

234 Traps per Minute

AP800 339

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 340: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

APS100-121An attendant pay station (service hall) is a public site where people canplace calls under the supervision of an attendant. The attendant assignstelephones to customers and collects the charges from those calls. Uponcompletion of each call that originated from the service hall, a log in therange APS100 to APS121 is generated. Generation of this log requires thatthe APS is provisioned to a line, the call originates at the service hall, andthe call has an originating number.

When the APS call ends, the system routes a record of the call details to alog device. The specific log name is selected by the combination of tablesDNSCRN, TOPSDB, and TDBCLASS; or by table SPLDNID. Either tableTDBCLASS field TDBCLSEL must be set to APSLOG, followed by the lognumber or table SPLDNID field SPLSEL must be set to APSLOG, followedby the log number.

If a device is not assigned in table TDBCLASS field TDBCLSEL or tableSPLDNID field SPLSEL, an APS call generates an APS100 log.

Logs APS100 through APS121 provide the same information.

Remedial actionWhen the system receives the log, you must collect payment for chargesthat the call incurs. If the log indicates zero charges, make sure theduration of the call is zero minutes.

Toll calls produce an AOCT100 log and an APS1xx log, where xx is in therange 00-21. The operating company evaluates both logs for meteringinformation.

For maintenance purposes, there is no action since this log is forinformation only.

340 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 341: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatAPS1XX MMMDD HH:MM:SS SSDD INFO APS LOG ENTRY

MSG COUNT = <MSG COUNT>

CALLING DN = <CLG DN>

CALLED DN = <CLD DN>

DATE = <DATE>

ANSWER TIME = <ANS. TIME>

DURATION = <DURATION>

CHARGES = <CHGS>

BOOTH = <BOOTH>

Selected field descriptionsField Value Fixed or

VariableDescription

CHARGES 10 charactersincluding pointplaceholders

Variable Indicates charges that the calling partyowes, which include the taxes.Depends on administration for units.

Calculation and display of chargesdepend on the following parameters:

• APS_DISPLAY_DOLLAR_SIGNin table TOPSPARM controlsdisplay of the dollar sign. Use Y todisplay.

• AMETER_PULSE_MONETARY_RATE in table OFCVAR is thecharge factor, It determines

APS100-121 341

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 342: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

charges that increase per pulsecount. It has a value range of 0 to100.

• CHG_DISPLAY_DECIMAL intable TOPSPARM determines thedigit length of the decimal part. Ithas a value range of 0 to 3.

BOOTH 6 alphanumericcharacters

Variable Indicates the booth number of theoriginating party. For direct dial calls(non-operator assisted), this value isalways zero.

ssdd 4 digits Variable Identifies the sequence number of thelog. The number of the log increaseswhen the system generates a log.

INFO APS LOGENTRY

constant Variable Identifies the type of Advice of Charge(AOC) log that the system generates.

MSG COUNT unsigned integer Variable Indicates the number of logs that thesystem generates of the same type.The message counter is unique toeach APS1XX log. There is anincrement whenever these logs aregenerated and is used to track anylost logs.

CALLING DN up to 18 digits Variable Indicates the directory number (DN) ofthe originating party.

CALLED DN up to 18 digits Variable Indicates the digits dialed by the calloriginator.

DATE mm/dd Variable Indicates the date the call originated.

ANSWER TIME hh:mm Variable Indicates the time of day the call wasanswered. If the user does not answerthe call, this field indicates theorigination time.

DURATION 0 to 999 Variable Indicates the duration of the call inminutes between answer anddisconnect. If the duration is less thanone minute, the field indicates oneminute.

Although the global rating systemsupports sub-period billing, and theactual charges for the call reflect anysub-period billing charges, the

342 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 343: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

duration of the call is rounded to thenearest minute when the call record isgenerated.

APS1xx constant, up to 6characters

Variable Identifies the log name.

mmmdd 5 alphanumericcharacters

Variable Identifies the month and day that thesystem generated the log.

hh:mm:ss 8 digits Variable Identifies the time at which the systemgenerated the log.

Active message exampleAPS118 MAY01 14:22:39 9806 APS LOG ENTRY

MSG COUNT = 1

CALLING DN = 1027835473

CALLED DN = 1027835475

DATE = 05/01

ANSWER TIME = 14:22

DURATION = 1

CHARGES = 20

BOOTH = 0

Clear message examplen/a

Associated OM registers

ARN600The Automatic Recall with Name (ARN) subsystem generates the ARN600information log when a call does not route to the service node (SN), or thecall to the SN meets an unsupported feature or agent.

ARN600 343

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 344: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionLog ARN600 indicates a problem with the call to the SN. To determine thecause of the problem, save the log for reference. Then examine the logreport to check the directory number (DN) that ARN used to route the SNand the treatment applied to the call. Also use the translations verification(TRAVER) tool to check the translations for the call to the SN.

Does not route to Service Node

Information log ARN600 has a value of "Fails to route to service node"when the call to the SN finds a treatment.

Examine the treatment field of the log report to determine what treatmentthe call to the SN encountered. Modify the datafill so the call to the SNavoids the treatment and uses the TRAVER tool to check the newtranslations.

AttributesAttribute Value

Severity Indeterminate

FormatARN600 mmmdd hh:mm:ss ssdd ARN log report

REASON : <rsntxt>

Call ID : <FFFF FFFF>

ARN DN : <NPAXXXXXX>

SN DN :<XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX>

Treatment : <trmnt>

Selected field descriptionsField Value Fixed or

VariableDescription

Reason Fails to route toService Node

Variable Error while routing to SN.

Unsupported type ofcall to SN

Variable Meets an unsupported feature oragent for the call to the SN.

Call ID integer Variable Call identification number

ARN DN 10 digits Variable Controller's directory number

344 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 345: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

SN DN 4 to 30 digits Variable Service node directory number

Treatment Treatment text of 4characters maximum

Variable Treatment applied to the call

Active message exampleARN600 MAR11 16:04:14 2300 ARN log report

REASON : Fails to route to Service Node

Call ID : 038B 0000

ARN DN : 5145425541

SN DN : 5148547855

Treatment : PSIG

Clear message examplen/a

Associated OM registers

ARN601The Automatic Recall with Name (ARN) subsystem generates informationlog ARN601 when the T1 timer expires, the T2 timer expires, or the ARNcould not allocate a clone virtual identifiers (CVID) to route the call to theservice node (SN).

Remedial actionSave the log and use it as additional information to investigate the failure ofthe SN to respond within the normal time range. Check the values of T1and T2. Also use the information to investigate the failure of the system toallocate enough resources to route the call to the SN. Check the value ofNO_OF_CLONE_TIDS exceeded.

AttributesAttribute Value

Severity Indeterminate

FormatARN601 mmmdd hh:mm:ss ssdd ARN log report

ARN601 345

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 346: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

REASON : <rsntxt>

CALL ID : <FFFF FFFF>

ARN DN : <NPANXXXXXX>

SN DN : <XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX>

Selected field descriptionsField Value Fixed or

VariableDescription

Reason T1 expired Variable The T1 timer expired.

T2 expired Variable The T2 timer expired.

NO_OF_CLONE_TIDS exceeded

Variable ARN could not allocate a necessaryresource to route the call to the SN.

Call ID integer Variable Call identification number

ARN DN 10 digits Variable Controller's directory number

SN DN 4 to 30 digits Variable Service node directory number

Active message exampleARN601 MAR11 16:04:14 2300 ARN log report

REASON : T1 expired

CALL ID : 038B 0000

ARN DN : 5145425541

SN DN : 5148547855

Clear message examplen/a

Associated OM registers

ATB100The All Trunks Busy (ATB) subsystem generates this report. The systemgenerates this report when the system blocks or attempts to seize an exactnumbering plan area (NPA) or central office (CO). The call advances toanother route. Generation of this log does not always mean that all trunksare busy. ATB conditions normally occur on high-traffic days. ATBconditions also occur when not enough allocated trunks are present tocarry traffic to the specified NPA or CO.

346 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 347: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionSave all ATB100 reports for network planning personnel.

AttributesAttribute Value

Severity Indeterminate

Format1.*ATB100 mmmdd hh:mm:ss ssdd TBL ALL_TRUNKS_BUSY

CODETYPE = codenm CODE = nnn

COUNT = nnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

TBLALL_TRUNKS_BUSY

Constant Fixed Indicates that no trunks were availableto route incoming calls to specifiedNPA or CO

CODETYPE NAP Variable Indicates CODE field contains an NPAcode

OFC Variable Indicates CODE field contains a COcode

CODE n0/1x Variable Specifies NPA for which the systemadvanced the call to another route (n= 2 to 9, and x = 0 to 9)

nxx Variable Specifies CO for which the systemadvanced the call to another route (n= 2 to 9, and x = 0 to 9)

COUNT 1 to 32767 Variable Indicates number of call attempts forNPA or CO advanced to another routeas a result of ATB conditions

Active message example1.*ATB100 APR01 12:00:00 2112 TBL ALL_TRUNKS_BUSY

CODETYPE = NPA CODE = 919

COUNT = 199

Clear message examplen/a

ATB100 347

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 348: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ATM301This log indicates that an LCD (Loss of Cell Delineation) condition hascleared on the ATM RM in the SPM node.

Log history

SN06 (DMS)

Log ATM301 was changed for Enhanced Logs Phase 2 by FeatureB89007430.

Remedial actionThe ATM301 report is for information only and requires no immediateaction.

AttributesAttribute Value

Severity • Warning

• Critical

Format<office>ATM301 <mmmdd><hh:mm:ss><ssdd>INFO ATM LCD AlarmCleared

Location: <location>

ATM RM in Slot: <slot_no>(<activity>)

Description: ATM LCD (Loss of Cell Delineation) criticalalarm raised.

Location: SPM <spm number>Type: <IW,SMG4,DPT>

Fabric: <ATM,N/A>

Selected field descriptionsField Value Fixed or

VariableDescription

office text Variable Office name

location SPM 0 to 85 Variable Affected SPM

slot_no 1, 2, 9, 10 Variable Slot number for ATM RM card

348 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 349: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

activity Act, Inact Variable Identifies whether the ATM RM in slot< slot no > was active or inactive

description ATM LCD (Loss ofCell Delineation)Alarm cleared.

Variable Meaning of log

class type SMG4 Variable MG4000

Used when the node class is datafilledas SMG4 in table MNNODE.

IW Variable Interworking SPM

Used when the node class is datafilledas IW and DPT_INFO is datafilled asBRIDGE_ONLY in table MNNODE.

DPT Variable Dynamic Packet Trunk (DPT) SPM

Used when the node class is datafilledas IW and DPT_INFO is datafilled asDPT_ONLY in table MNNODE.

fabric ATM Variable Table MNCKTPAK CPKTYPE = ATM

Active message exampleRTP9N04BF ATM300 SEP23 10:06:12 1001 INFO ATM LCD AlarmCleared

Location: SPM 0

ATM RM in Slot: 1 (Act)

Description: ATM LCD (Loss of Cell Delineation)criticalalarm cleared.

Location: SPM 0 Type: DPT Fabric: ATM

Clear message examplen/a

Associated OM registers

ATM500This log gives the ILMI status and version.

Log history

ATM500 349

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 350: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

SN06 (DMS)

Log ATM500 was changed for Enhanced Logs Phase 2 by FeatureB89007430

Remedial actionThe ATM500 report is for information only and requires no immediateaction.

AttributesAttribute Value

Severity Warning

Format<office>ATM500 <mmmdd><hh:mm:ss><ssdd>INFO ATM ILMI Status

Location: <location>ILMI: <version>

Status: <Up, Down>

Description: ILMI status has changed.

Location: SPM <spm number>Type: <IW, SMG4,DPT>

Fabric: <ATM,N/A>

Selected field descriptionsField Value Fixed or

VariableDescription

office text Variable Office name

location SPM 0 to 85 Variable Affected SPM

ilmi version < 3.1, 4.0 > Variable ILMI version

status < Up, Down > Variable ILMI status

description ILMI status haschanged.

Variable Meaning of log

class type SMG4 Variable MG4000

Used when the node class is datafilledas SMG4 in table MNNODE.

IW Variable Interworking SPM

Used when the node class is datafilledas IW and DPT_INFO is datafilled asBRIDGE_ONLY in table MNNODE.

350 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 351: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

DPT Variable Dynamic Packet Trunk (DPT) SPM

Used when the node class is datafilledas IW and DPT_INFO is datafilled asDPT_ONLY in table MNNODE.

fabric ATM Variable Table MNCKTPAK CPKTYPE = ATM

Active message exampleRTP9N04BF ATM500 SEP23 10:07:03 1203 INFO ATM ILMI STATUS

Location: SPM 0 ILMI: 4.0

Status: Up

Description: ILMI Status has changed.

Location: SPM 0 Type: DPT Fabric: ATM

Clear message examplen/a

Associated OM registers

ATM601This log indicates that the ATM RM in the SPM node has lost itsregistration with the ATM network and that calls cannot be set up.

Log history

SN06 (DMS)

Log ATM601 was changed for Enhanced Logs Phase 2 by FeatureB89007430.

Remedial actionThe ATM601 report is for information only and requires no immediateaction.

AttributesAttribute Value

Severity Warning

ATM601 351

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 352: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Format<office>ATM601 <mmmdd><hh:mm:ss><ssdd>INFO ATM AddressDeregistration

Location: <location>

Description: ATM has lost its registered ATM address.

Reason: <text>

Location: SPM <spm number>Type: <IW, SMG4, DPT>

Fabric: <ATM, N/A>

Selected field descriptionsField Value Fixed or

VariableDescription

office text Variable Office name

location SPM 0 to 85 Variable Affected SPM

reason reason text Variable Why the ATM lost its registered ATMaddress

class type SMG4 Variable MG4000

Used when the node class is datafilledas SMG4 in table MNNODE.

IW Variable Interworking SPM

Used when the node class is datafilledas IW and DPT_INFO is datafilled asBRIDGE_ONLY in table MNNODE.

DPT Variable Dynamic Packet Trunk (DPT) SPM

Used when the node class is datafilledas IW and DPT_INFO is datafilled asDPT_ONLY in table MNNODE.

fabric ATM Variable Table MNCKTPAK CPKTYPE = ATM

Active message exampleRTP9N04BF ATM601 SEP23 10:06:13 1001 INFO ATM AddressDeregistration

Location: SPM 0

Description: ATM has lsot its registered ATM address.

Reason: ATM address has been deregistered by ATM network.

352 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 353: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Location: SPM 0 Type: DPT Fabric: ATM

Clear message examplen/a

Associated OM registers

ATM604This log indicates that the system software cannot recover the ATMframework, and this causes the ATM RM to be busied and RTSed.

Log history

SN06 (DMS)

Log ATM604 was changed for Enhanced Logs Phase 2 by FeatureB89007430.

Remedial actionThe ATM604 report is for information only and requires no immediateaction.

AttributesAttribute Value

Severity Warning

Format<office>ATM604 <mmmdd><hh:mm:ss><ssdd>INFO ATM RecoveryAudit

Location: <pm_no>ATM RM in Slot: <slot_no>(<activity>)

Description: Unable to establish PVCs after multipleattempts. System will Bsy and RTS the RTM RM. Location: SPM<spm number>Type:

<IW,SMG4,DPT>Fabric: <ATM,N/A>

Selected field descriptionsField Value Fixed or

VariableDescription

office text Variable Office name

date mmmdd Variable Month and day

time hh:mm:ss Variable Hour, minute and second

ATM604 353

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 354: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

log_no dddd Variable Standard log number

pm_no SPM 0 to 85 Variable SPM number

slot_no 1 to 14 Variable Slot number for ATM RM card

activity Act, Inact Variable Identifies whether the ATM RM in slot< slot no > was active or inactive

class type SMG4 Variable MG4000

Used when the node class is datafilledas SMG4 in table MNNODE.

IW Variable Interworking SPM

Used when the node class is datafilledas IW and DPT_INFO is datafilled asBRIDGE_ONLY in table MNNODE.

DPT Variable Dynamic Packet Trunk (DPT) SPM

Used when the node class is datafilledas IW and DPT_INFO is datafilled asDPT_ONLY in table MNNODE.

fabric ATM Variable Table MNCKTPAK CPKTYPE = ATM

Active message exampleRTP9N04BF ATM604 FEB05 10:12:21 4300 INFO ATM Recovery Audit

Location: SPM 0

ATM RM in Slot: 1 (Act)

Description: Unable to establish PVCs after multipleattempts. System will Bsy and RTS the RTM RM.

Location: SPM 0 Type: DPT Fabric: ATM

Clear message examplen/a

Associated OM registers

ATM606This log reports a call failure owing to problems in the ATM network.

The log is generated when the Succession Network receives a UNIRelease Complete message indicating an unsuccessful attempt to set upATM bearer path (SVC) through the ATM network. This log displays the

354 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 355: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

ATM release cause value and reason as received from the Passport15000, the originating and terminating agent information, Called Number,and Call ID.

Log history

SN06 (DMS)

Log ATM606 was changed for Enhanced Logs Phase 2 by FeatureB89007430.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

Format<office>ATM606 <mmmdd><hh:mm:ss><ssdd>INFO ATM SVC Failure

Location: <location>

Orig Agent: <agent>

Term Agent: <agent>

Called Number: <called number>

Call ID: <call ID>

Cause: <cause>

Location: SPM <spm number>Type: <IW,SMG4,DPT>

Fabric: <ATM,N/A>

Selected field descriptionsField Value Fixed or

VariableDescription

office text Variable Office name

location SPM 0 to 85 Variable Affected SPM

agent string Variable The trunk's equipment identifier

called number Variable The number being called

ATM606 355

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 356: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

call ID Variable The internal ID used to refer to the call

cause Variable The specific UNI Release Causevalue supplied by the ATM network toindicate why the call could not be setup.

class type SMG4 Variable MG4000

Used when the node class is datafilledas SMG4 in table MNNODE.

IW Variable Interworking SPM

Used when the node class is datafilledas IW and DPT_INFO is datafilled asBRIDGE_ONLY in table MNNODE.

DPT Variable Dynamic Packet Trunk (DPT) SPM

Used when the node class is datafilledas IW and DPT_INFO is datafilled asDPT_ONLY in table MNNODE.

fabric ATM Variable Table MNCKTPAK CPKTYPE = ATM

Active message exampleRTP9N04BF ATM606 JAN17 12:50:42 9200 INFO ATM SVC Failure

Location: SPM 2

Orig Agent: DPT GRP

Term Agent: ckt mgea36c7dr07 1

Called Number: 5014441111

Call ID: 17006593

Description: SPM has a registered ATM address.

Location: SPM 0 Type: DPT Fabric: ATM

CS0004BB ATM606 JAN17 12:50:42 9200 INFO ATM SVC Failure

Location: SPM 2

Orig Agent: DPT GRP

Term Agent: CKT MGEA36C7DR07 1

356 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 357: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Called Number: 5014441111

Call ID: 17006593

CAUSE = 3 NO_ROUTE_TO_DEST

Location: SPM 0 Type: DPT Fabric: ATM

Clear message examplen/a

Associated OM registers

ATME200The Automatic Transmission Measuring Equipment (ATME) subsystemgenerates ATME200. The system generates ATME200 when aninternational circuit passes the Consultative Committee on InternationalTelephony and Telegraphy (CCITT) ATME No. two tests. There are 25 testcodes. Each code represents a collection of signaling tests andtransmission measurements. The subsystem will not generate all of thefields in this report. This is because the system does not perform all of thetests. The fields that are optional appear in parentheses ( ).

Remedial actionn/a

AttributesAttribute Value

Severity Indeterminate

FormatATME200 mmmdd hh:mm:ss ssdd PASS PASS

CKT trkid

DIR:BASE=+/-nn.n?/! 400=+/-nn.n?/! 2800=+/-nn.n?/!

NOISE=+/-nn?/!

RES: =/-nn.n?/! =+/-nn.n?/! =+/-nn.n?/!

=+/-nn?/!

tsttxt SIG: sigtxt MEAS: meastxt

ATME200 357

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 358: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

(400=+/-nn.n?/!) Refer to precedingvalue.

Variable Indicates the measured power level asthe power level deviates from theBase level. The frequency of thesignaling source must be 400hz. Referto preceding description forexplanation of +/- and ?/!.

(2800=+/-nn.n?/!) Refer to precedingvalue.

Variable Indicates the measured power level asthe power level deviates from theBase level The frequency of thesignaling source must be 2800 hz.Refer to preceding description forexplanation of +/- and ?/!.

(NOISE= nn.n?/!) 0-90 Variable Indicates the measured noise level indBrn (phosphometric weighting, referto CCITT recommendations). Thesystem stores Q limits against eachcircuit in Table CLLIMTCE. Refer toGateway Customer Data Schema ,297-2301-451, for additionalinformation.

RES: Constant Fixed Indicates that the fields that followcontain the results of Respondermeasurements. Tone originates in thenear office or measurement in the faroffice are examples of Respondermeasurements.

(Base=+/-nn.n?/!) Refer to precedingvalue.

Variable Refer to DIR.

(400=+/-nn.n?/!) Refer to precedingvalue.

Variable Refer to DIR.

(2800=+/-nn.n?/!) Refer to precedingvalue.

Variable Refer to DIR.

(NOISE= nn.n?/!) Refer to precedingvalue.

Variable Refer to DIR.

(tsttxt) AN CB RA BF Variable Gives the response of a signaling test.If the system performed a test, asgiven in field SIG: sigtxt, the resultsare output.

AN Variable Indicates the system received answer.

CB Variable Indicates the system received clear-back.

358 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 359: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

RA Variable Indicates the system received re-answer.

BF Variable Indicates the system received busy-flash.

SIG: sigtxt Variable Gives the type of signaling test thesystem performed.

NONE Variable Indicates that the system did notperform a test.

FULL Variable Indicates that the system performed afull signaling test. The response isanswer, clear-ack, re-answer.

SHORT Variable Indicates that the system performed ashort signaling test. The response isanswer.

BSY Variable Indicates that the international circuitperformed the busy signal test. Theresponse is busy-flash.

FULL BSY Variable Indicates the system performed thefull and the busy signaling tests. Theresponse is answer clear-back, re-answer and busy-flash.

SHORT BSY Variable Indicates the system performed theshort and the busy signaling tests.The response is answer busy-flash.

MEAS: meastxt Variable Gives the type of transmissionmeasurement the system performed.

NONE Variable Indicates the system did not perform atransmission measurement.

L Variable Indicates loss at base frequencymeasurement.

LFD Variable Indicates loss frequency deviationmeasurement.

N Variable Indicates noise measurement.

L N Variable Indicates loss at base frequency andnoise measurement.

LFD N Variable Indicates loss frequency deviation andnoise measurement.

PASS PASS Constant Fixed Indicates that the test passed.

CKT trkid Symbolic text Variable Gives the CLLI and CKT number forthe circuit. Table I.

ATME200 359

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 360: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

DIR Constant Fixed Indicates that the fields that followcontain the results of directormeasurements. Tone originates at faroffice or measurement at near officeare examples of directormeasurements.

(BASE=+/-nn.n?/!) (+99.9dBm ?/!) to(-99.9dBm?/!)

Variable Indicates the measured power level indBm, at 800hz or 1000hz thatdeviates from the expected value. +indicates that the level is higher thanthe nominal.- indicates that the level islower than nominal. ? indicates thatthe level exceeds the maintenancelimits (Q1). ! indicates that the levelexceeds the immediate action limits(Q2). If a ? or an ! is not present, thelevel does not exceed the limits. ForAutomatic Trunk Testing (ATT), theoperating company enters Q limits inTable ATMEQ.

Active message exampleATME200 JUN19 02:48:01 7700 PASS PASS

CKT N5LOOP 50

DIR: BASE= -1.1 400= +0.0 2800= +0.0 NOISE= -62

RES: -1.0 +0.1 +0.1 -62

AN SIG: NONE MEAS: LFD N

Clear message examplen/a

Associated OM registers

ATME201The Automatic Transmission Measuring Equipment (ATME) subsystemgenerates ATME201. The subsystem generates ATME201 when theinternational circuit fails the Consultative Committee on InternationalTelephony and Telegraphy (CCITT) ATME No. 2 tests. These tests test aninternational circuit. There are 25 test codes. The test codes determine thetests performed. Each code represents a collection of signaling tests and

360 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 361: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

transmission measurements. The system does not generate all of the fieldsbecause the codes does not perform all of the tests. The symbols ( )denote fields as optional.

Remedial actionManually test the circuit to determine the fault location.

AttributesAttribute Value

Severity Indeterminate

Format1.**ATME201 mmmdd hh:mm:ss ssdd FAIL SIG

CKT trkid

DIR:BASE=+/-nn.n?/! 400=+/-nn.n?/! 2800=+/-nn.n?/!NOISE=nn?/!

RES:Base=+/-nn.n ?/! 400=+/-nn.n?/! 2800=+/-nn.n?/! NOISE=nn?/!

tsttxt SIG: sigtxt MEAS: meastxt

msgtxt CKT TTU n

Selected field descriptionsField Value Fixed or

VariableDescription

Field Value Variable Description

FAIL SIG Constant Fixed Indicates that the signaling test failed.

CKT Symbolic text Variable Gives the common language locationidentifier (CLLI) and CKT number forthe trunk circuit.

DIR Constant Fixed Indicates that the fields that followcontain the results of directormeasurements. Tone originates atdistant office, measurement at nearoffice are examples of these results.

(BASE=+/-nn.n?/!) (+99.9dBm ?/!) to(-99.9dBm ?/!)

Variable Indicates the measured power level, indBm, at 800hz or 1000hz, thatdeviates from the expected value. +indicates the level is higher than thenominal.- indicates that the level is

ATME201 361

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 362: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

lower than the nominal. ? indicatesthat the level exceeds theMaintenance Limits (Q1). ! indicatesthat the level exceeds the ImmediateAction Limits (Q2). For test trunkposition (TTP), the Q limits are preset.If a ? or an ! are not present, the leveldoes not exceed the limits. Forautomatic trunk testing (ATT), theoperating company enters the Qlimits. Table ATMEQ describes thisprocedure. Refer to the data schemasection of the Translations Guide foradditional information.

(400=+/-nn.n?/!) Refer to above. Variable Indicates the measured power level,as the power level deviates from thebase level. At the base level, thefrequency of the signaling source is400hz. Refer to the precedingdescription for an explanation of +/-and ?/!.

(2800=+/-nn.n?/!) Refer to above. Variable Indicates the measured power level asthe power level deviates from thebase level. At the base level, thefrequency of the signaling source is2800 hz. Refer to the precedingdescription for an explanation of +/-and ?/!.

(NOISE= nn.n?/!) 0-90 Variable Indicates the measured noise level indBrn. For phosphometric weighting,refer to CCITT recommendations. Thesystem stores the Q limits againsteach circuit, in table CLLIMTCE. Referto the data schema section of theTranslations Guide for additionalinformation.

RES: Constant Fixed Indicates that the fields that followcontain the results of respondermeasurements. The tone originates inthe near office and measurements inthe distant office are examples ofthese measurements.

(Base=+/-nn.n?/!) Refer to DIR. Variable (400=+/-nn.n?/!)

Refer to DIR. (2800=+/-nn.n?/!) Variable Refer to DIR.

362 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 363: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

(NOISE= nn.n?/!) Refer to DIR. Variable (tsttxt)

AN CB RA BF Gives the response ofa Signaling Test. Thesystem generatesresults if the systemperformed a signallingtest, as SIG:sigtxtspecifies.

Variable

AN Indicates that thesystem receivedanswer.

Variable

CB Indicates that thesystem receivedclear-back.

Variable

RA Indicates the systemreceived re-answer.

Variable

BF Indicates the systemreceived busy-flash.

Variable SIG

Gives the type ofsignaling test thesystem performed.

Variable NONE

Indicates the systemdid not perform a test.

Variable FULL

Indicates the systemperformed fullsignaling test. Theresponse is answer,clear-back, re-answer.

Variable SHORT

Indicates the systemperformed shortsignaling test. Theresponse is answer.

Variable BSY

Indicates the systemperformed busysignaling test. Theresponse is busy-flash.

Variable FULL BSY

Indicates the systemperformed the full andthe busy signalingtests. The response is

Variable SHORT BSY

ATME201 363

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 364: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

answer, clear-back,re-answer and busy-flash.

Indicates the systemperformed short andthe busy signalingtests. The response isanswer or busy-flash.

MEAS Variable Gives the type of transmissionmeasurement performed.

NONE Variable Indicates the system did not perform atransmission measurement.

L Variable Indicates loss at base frequencymeasurement.

LFD Variable Indicates loss at frequency deviationmeasurement.

N Variable Indicates noise measurement.

L N Variable Indicates loss at base frequency andnoise measurement.

LFD N Variable Indicates loss at frequency deviationand noise measurement.

(msgtxt) Symbolic text Variable Gives additional informationconcerning why the test failed. Referto table Q.

(CKT TTU n) 0-9 Variable Identifies the transmission test unit.The system generates this field only ifthe test uses transmission test unit(TTU) equipment.

Active message example1.**ATME201 JUN19 03:18:41 5300 FAIL SIG

CKT N5LOOP 50

AN SIG:FULL MEAS: NONE

CLEAR_BACK_NOT_REC CKT TTU 0

Clear message examplen/a

364 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 365: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ATME202The Automatic Transmission Measuring Equipment (ATME) subsystemgenerates ATME202. The subsystem generates ATME202 when theConsultative Committee on International Telephony and Telegraphy(CCITT) ATME No. two tests fail the Busy Signaling test. The systemapplies the CCITT ATME No. two tests to an international circuit.

There are 25 test codes. Each code represents a group of signaling testsand transmission measurements. The system performed a many tests. Thetest code chooses the tests. The system will not generate all of the fieldsbecause the system does not run all of the tests. Optional fields appear asparentheses ( ).

Remedial actionManually test the circuit to determine the fault location.

AttributesAttribute Value

Severity Indeterminate

Format*ATME202 mmmdd hh:mm:ss ssdd FAIL BSY

CKT trkid

DIR:BASE=+/-nn.n?/! 400=+/-nn.n?/! 2800=+/-nn.n?/!

NOISE=+/-nn?/!

RES: =/-nn.n?/! =+/-nn.n?/! =+/-nn.n?/!

=+/-nn?/!

tsttxt SIG: sigtxt MEAS: meastxt

msgtxt CKT TTU n

Selected field descriptionsField Value Fixed or

VariableDescription

(BASE=+/-nn.n?/!) (+99.9dBm ?/!) to(-99.9dBm ?/!)

Variable Indicates the measured power level indBm, at 800hz or 1000hz, thatdeviates from the expected value. +

ATME202 365

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 366: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

indicates the level is higher than thenominal,- indicates that the level islower than the nominal. ? indicatesthat the level exceeds theMaintenance Limits (Q1), ! indicatesthat the level exceeds the ImmediateAction Limits (Q2). If a ? or an ! arenot present, the level does not exceedthe limits. For TTP, the Q limits arepreset. For automatic trunk testing(ATT), the operating company TableATMEQ enters the Q limits. Refer tothe data schema section of theTranslations Guide .

(400=+/-nn.n?/!) Refer to precedingvalue.

Variable Indicates the measured power level,as the power level deviates from thebase level, At this time, the frequencyof the signaling source is 400hz. Referto the preceding description for anexplanation of +/- and ?/!.

(2800=+/-nn.n?/!) Refer to precedingvalue.

Variable Indicates the measured power level asthe power level deviates from thebase level. At this time, the frequencyof the signaling source is 2800 hz.Refer to the preceding description foran explanation of +/- and ?/!.

(NOISE= nn.n?/!) 0-90 Variable Indicates the measured noise level indBrn phosphometric weighting. Referto CCITT recommendations. Thesystem stores the Q limits againsteach circuit. Refer to TableCLLIMTCE. Refer also to the dataschema section of the TranslationsGuide .

RES Constant Fixed Indicates that the following fieldscontain the results of respondermeasurements. Tone originates in thenear office, measurements at the faroffice are examples of these results.

(Base=+/-nn.n?/!) Variable Refer to DIR.

(400=+/-nn.n?/!) Variable Refer to DIR.

(2800=+/-nn.n?/!) Variable Refer to DIR.

(NOISE= nn.n?/!) Variable Refer to DIR.

366 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 367: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

(tsttxt) AN CB RA BF Variable Gives the response of a signaling test.If the system performs a signalingtest, as field SIG specifies, the resultsare output.

AN Variable Indicates system received answer.

CB Variable Indicates system received clear-back.

RA Variable Indicates system received re-answer.

BF Variable Indicates system received busy-flash.

SIG Variable Gives the type of signaling test thesystem performed.

NONE Variable Indicates the system did not perform atest.

FULL Variable Indicates the full signaling test. Theresponse is answer, clear-back, re-answer.

SHORT Variable Indicates the system performed theshort signaling test. The response isanswer.

BSY Variable Indicates the system performed busysignaling test. The response is busy-flash.

FULL BSY Variable Indicates the system performed thefull and the busy signaling tests. Theresponse is answer, clear-back, re-answer and busy-flash.

SHORT BSY Variable Indicates the system performed theshort and busy signaling tests. Theresponse is answer, busy-flash.

MEAS Variable Gives the type of transmissionmeasurement performed.

NONE Variable Indicates that the system did notperform transmission measurement.

L Variable Indicates loss at base frequencymeasurement.

LFD Variable Indicates loss at frequency deviationmeasurement.

N Variable Indicates noise measurement.

L N Variable Indicates loss at base frequency andnoise measurement.

ATME202 367

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 368: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

LFD N Variable Indicates loss frequency deviation andnoise measurement.

(msgtxt) Symbolic text Variable Gives additional information on thereason the test failed. Refer to TableQ.

(CKT TTU n) 0-9 Variable Identifies the transmission test unit(TTU). This field is output if the testused TTU.

FAIL BSY Constant Fixed Indicates that the busy test failed.

CKT Symbolic text Variable Gives the common language locationidentifier (CLLI) and CKT number forthe trunk circuit.

DIR Constant Fixed Indicates that the fields that followcontain the results of directormeasurements. Tone originates in thedistant office, measurements at nearoffice are examples of these results.

Active message exampleATME202 JUN19 03:24:22 9900 FAIL BSY

CKT N5LOOP 50

SIG: BSY MEAS: NONE

BSY_FLASH_NOT_REC

Clear message examplen/a

Associated OM registers

ATME203The Automatic Transmission Measuring Equipment (ATME) subsystemgenerates ATME203. The subsystem generates ATME203 when the Q1(maintenance) limit is exceeded. The limit is exceeded because of theConsultative Committee on International Telephony and Telegraphy(CCITT) ATME No. 2 tests. These tests are applied to an internationalcircuit. There are 25 test codes. Each code represents a combination ofsignaling tests and transmission measurements. The test code determinesthe variety of tests performed. The subsystem generates does notgenerate all of the fields because the system does not run all of the tests.Optional fields appear as ( ).

368 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 369: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionPerform maintenance action if Q1 is exceeded. Test the circuit againmanually.

AttributesAttribute Value

Severity Indeterminate

Format1.**ATME203 mmmddhh:mm:ss ssdd FAIL Q1

CKT trkid

DIR:BASE=+/-nn.n?/! 400=+/-nn.n?/! 2800=+/-nn.n?/!NOISE=nn?/!

RES:Base=+/-nn.n?/! 400=+/-nn.n?/! 2800=+/-nn.n?/! NOISE=nn?/!

tsttxt SIG: sigtxt MEAS: meastxt

msgtxt CKT TTU n

Selected field descriptionsField Value Fixed or

VariableDescription

FAIL Q1 Constant Fixed Measurement exceeds the Q1.

CKT Symbolic text Variable Gives the common language locationidentifier (CLLI) and CKT number forthe trunk circuit.

DIR Constant Fixed Indicates that the following fieldscontain the results of directormeasurements. Tone originates atdistant office or measurement at nearoffice are examples of these results.

(BASE=+/-nn.n?/!) (+99.9dBm ?/!) to(-99.9dBm ?/!)

Variable Indicates the measured power level indBm, at 800hz or 1000hz thatdeviates from the expected value. +indicates the level is higher than thenominal- indicates that the level islower than the nominal. ? indicatesthat the level exceeds the Q1 !indicates that the level exceeds theImmediate Action Limits (Q2). If a ? oran ! is not present, then the level does

ATME203 369

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 370: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

not exceed the limits. For trunk testposition (TTP), the Q limits are preset.For automatic trunk testing (ATT) theoperating company enters the Q limitsin table ATMEQ. Refer to the dataschema section of the TranslationsGuide for additional information.

(400=+/-nn.n?/!) See preceding value. Variable Indicates the measured power level,as the power level deviates from thebase level. At this time, the frequencyof the signaling source is 400hz. Referto description above for +/-and ?/!.

(2800=+/-nn.n?/!) See preceding value. Variable Indicates the measured power level asthe power level deviates from thebase level. At this time, the frequencyof the signaling source is 2800 hz.Refer to description above for +/-and ?/!.

(NOISE= nn.n?/!) 0-90 Variable Indicates the measured noise level indBrn (phosphometric weighting). SeeCCITT recommendations. The systemstores the Q limits against each circuitin Table CLLIMTCE. Refer to the dataschema section of the TranslationsGuide for additional information.

RES: Constant Fixed Indicates that the fields that followcontain the results of respondermeasurements. The tone originates inthe near office or measurements atthe distant office are examples ofresponder measurements.

(Base=+/-nn.n?/!) Variable Refer to DIR

(400=+/-nn.n?/!) Variable Refer to DIR

(2800=+/-nn.n?/!) Variable Refer to DIR

(NOISE= nn.n?/!) Variable Refer to DIR

(tsttxt) AN CB RA BF Variable Gives the response of a signaling test.The results are output only if thesystem performed a signaling test, asSIG: sigtxt specifies.

AN Variable Indicates the system received answer.

CB Variable Indicates the system received clear-back.

370 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 371: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

RA Variable Indicates the system received re-answer.

BF Variable Indicates the system received busy-flash.

SIG Variable Gives the type of signaling test thesystem performed.

NONE Variable Indicates the system did not perform atest.

FULL Variable Indicates the system performs fullsignaling test. The response isanswer, clear-back or re-answer.

SHORT Variable Indicates the system performs shortsignaling test. The response isanswer.

BSY Variable Indicates the system performs busysignaling test. The response is busy-flash.

FULL BSY Variable Indicates the system performed thefull and busy signaling tests. Theresponse is answer, clear-back, re-answer or busy-flash.

SHORT BSY Variable Indicates the system performed theshort and the busy signaling tests.The response is answer or busy-flash.

MEAS Variable Gives the type of transmissionmeasurement the system performed.

NONE Variable Indicates the system did not perform atransmission measurement.

L Variable Indicates loss at base frequencymeasurement.

LFD Variable Indicates loss at frequency deviationmeasurement.

N Variable Indicates noise measurement.

L N Variable Indicates loss at base frequency andnoise measurement.

LFD N Variable Indicates loss frequency deviation andnoise measurement.

ATME203 371

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 372: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

(msgtxt) Symbolic text Variable Gives additional informationconcerning why the test failureoccurred. Refer to table Q.

(CKT TTU n) 0-9 Variable Identifies the transmission test unit(TTU). The system generates this fieldonly if the test uses TTU equipment.

Active message example1.**ATME203 JUN19 03:48:39 0369 FAIL Q1

CKT N5LOOP 53

DIR: BASE= -1.1?

RES: -1.0?

AN SIG: NONE MEAS: L

Clear message examplen/a

Associated OM registers

ATME204The Automatic Transmission Measuring Equipment (ATME) subsystemgenerates ATME204. The subsystem generates ATME204 when theConsultative Committee on International Telephony and Telegraphy(CCITT) ATME No. 2 tests fail. These tests are applied to internationalcircuits. A test failure occurs when the Q2 (immediate action) limit isexceeded. Each of the 25 test codes represents a group of signaling testsand transmission measurements. The test code determines which tests thesystem runs. The subsystem does not generate all of the fields in this logreport because the system does not run all of the tests. The optional fieldsappear as ( ).

There is no additional information

Remedial actionIf the test result exceeds Q2, the circuit requires immediate maintenanceaction. You must manually test the circuit again.

372 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 373: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Indeterminate

Format1.**ATME203 mmmddhh:mm:ss ssdd FAIL Q2

CKT trkid

DIR:BASE=+/-nn.n?/! 400=+/-nn.n?/! 2800=+/-nn.n?/!NOISE=nn?/!

RES:Base=+/-nn.n ?/! 400=+/-nn.n?/! 2800=+/-nn.n?/! NOISE=nn?/!

tsttxt SIG: sigtxt MEAS: meastxt

msgtxt CKT TTU n

Selected field descriptionsField Value Fixed or

VariableDescription

(BASE=+/-nn.n?/!) (+99.9dBm ?/!) to(-99.9dBm ?/!)

Variable Indicates the measured power level, indBm at 800hz or 1000hz, thatdeviates from the expected value. +indicates the level is higher than thenominal. - indicates that the level islower. ? indicates that the levelexceeds the Maintenance Limits(Q1). ! indicates that the level exceedsthe Q2. When a ? or an ! are notpresent, the level does not exceed thelimits. For trunk test position (TTP),the Q limits are preset. For automatictrunk testing (ATT), the operatingcompany enters the Q limits in TableATMEQ. Refer to the data schemasection of the Translations Guide foradditional information.

(400=+/-nn.n?/!) Refer to precedingvalue.

Variable Indicates the measured power level,as the power level deviates from thebase level. At this time, the frequencyof the signaling source is 400hz. Referto the description above for anexplanation of +/- and ?/!.

ATME204 373

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 374: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

(2800=+/-nn.n?/!) Refer to precedingvalue.

Variable Indicates the measured power level asthe power level deviates from thebase level. At this time, the frequencyof the signaling source is 2800 hz.Refer to the description above for +/-and ?/!.

(NOISE= nn.n?/!) 0-90 Variable Indicates the measured noise level indBrn phosphometric weighting. Referto CCITT recommendations. TableCLLIMTCE contains the Q limitsstored against each circuit. Refer tothe data schema section of theTranslations Guide for additionalinformation.

RES Constant Fixed Indicates that the fields that followcontain the results of respondermeasurements. Tone originates in thenear office, measurements at thedistant office are examples of theseresults.

(Base=+/-nn.n?/!) Variable Refer to DIR.

(400=+/-nn.n?/!) Variable Refer to DIR.

(2800=+/-nn.n?/!) Variable Refer to DIR.

(NOISE= nn.n?/!) Variable Refer to DIR.

(tsttxt) AN CB RA BF Variable Gives the response of a signaling test.The results are only output if thesystem did a signaling test, as fieldSIG specifies.

AN Variable Indicates the system received answer.

CB Variable Indicates the system received clear-back.

RA Variable Indicates the system received re-answer.

BF Variable Indicates the system received busy-flash.

SIG Variable Gives the type of signaling test thesystem performed.

NONE Variable Indicates the system did not perform atest.

FULL Variable Indicates the system performed a fullsignaling test. The response isanswer, clear-back, re-answer.

374 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 375: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

SHORT Indicates the systemperformed a short signaling test. Theresponse is answer.

BSY Variable Indicates the system performed abusy signaling test. The response isbusy-flash.

FULL BSY Variable Indicates the system performed thefull and the busy signaling tests. Theresponse is answer, clear-back, re-answer or busy-flash.

SHORT BSY Variable The system performed the short andthe busy signaling tests. The responseis answer or busy-flash.

MEAS Variable Gives the type of transmissionmeasurement performed.

NONE Variable Indicates the system did not performtransmission measurement.

L Variable Indicates loss at base frequencymeasurement.

LFD Variable Indicates loss frequency deviationmeasurement.

N Variable Indicates noise measurement.

L N Variable Indicates loss at base frequency andnoise measurement.

LFD N Variable Indicates loss frequency deviation andnoise measurement.

(msgtxt) Symbolic text Variable Gives additional informationconcerning why the test failed. Referto Table Q.

(CKT TTU n) 0-9 Variable Identifies the transmission test unit(TTU).This system generates this fieldif test uses TTU equipment.

FAIL Q2 Constant Fixed Measurement exceeds the Q2(immediate action limits).

ATME204 375

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 376: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

CKT Symbolic text Variable Gives the common language locationidentifier (CLLI) and the CKT numberfor the trunk circuit.

DIR Constant Fixed Indicates that the fields that followcontain the results of directormeasurements. Tone originates atdistant office, measurements at nearoffice are examples of these results.

Active message example1.**ATME204 JUN19 03:51:22 3602 FAIL Q2

CKT N5LOOP 53

DIR: BASE= -1.1!

RES: -1.1!

AN SIG: NONE MEAS: L

Clear message examplen/a

Associated OM registers

ATME205The Automatic Transmission Measuring Equipment (ATME) subsystemgenerates ATME205. The subsystem generates ATME205 when theConsultative Committee on International Telephony and Telegraphy(CCITT) ATME No. 2 tests fail. These tests are applied to internationalcircuits. A test failure indicates that the near end of the circuit is busy(NBSY). Each of the 25 test codes represents a group of signaling testsand transmission measurements. The system performs tests based on thetest code. The system does not generate some fields in the report becausethe system does not perform all of the tests. The system denotes thesefields as optional by ( ).

There is no additional information

Remedial actionYou can use the RTSFAIL command in ATME level at the MAP(maintenance and administration position) to test the circuit again.

376 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 377: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Indeterminate

Format1.*ATME205 mmmdd hh:mm:ss ssdd FAIL NBSY

CKT trkid

DIR:BASE=+/-nn.n?/! 400=+/-nn.n?/! 2800=+/-nn.n?/! NOISE=+/-nn?/!

RES: =/-nn.n?/! =+/-nn.n?/! =+/-nn.n?/! =+/-nn?/!

tsttxt SIG: sigtxt MEAS: meastxt

msgtxt CKT TTU n

Selected field descriptionsField Value Fixed or

VariableDescription

(2800=+/-nn.n?/!) Refer to precedingvalue.

Variable Indicates the measured power level asthe power level deviates from thebase level. At this time, the frequencyof the signaling source is 2800 hz.Refer to preceding description for +/-and ?/!.

(NOISE= nn.n?/!) 0-90 Variable Indicates the measured noise level indBrn (phosphometric weighting).Refer to CCITT recommendations.The system stores the Q limits againsteach circuit in Table CLLIMTCE.Refer to the data schema section ofthe Translations Guide for additionalinformation.

RES: Constant Fixed Indicates that the following fieldscontain the results of respondermeasurements. Tone originates in thenear office or measurements at thedistant office are examples of theseresults.

(Base=+/-nn.n?/!) Variable Refer to DIR.

(400=+/-nn.n?/!) Variable Refer to DIR.

(2800=+/-nn.n?/!) Variable Refer to DIR.

ATME205 377

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 378: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

(NOISE= nn?/!) Variable Refer to DIR.

(tsttxt) AN CB RA BF Variable Gives the response of a SignalingTest. The system generates resultsonly when the system preforms asignaling test, as field SIG specifies.

AN Variable Indicates the system received answer

CB Variable Indicates the system received clear-back

RA Variable Indicates the system received re-answer

BF Variable Indicates the system received busy-flash

SIG Variable Gives the type of signaling test thesystem performed

NONE Variable Indicates system did not perform test

FULL Variable Indicates the system performed thefull signaling test. The response isanswer, clear-back or re-answer.

SHORT Variable Indicates the system performed theshort signaling test. The response isanswer.

BSY Variable Indicates the system performed thebusy signaling test. The response isbusy-flash.

FULL BSY Variable Indicates the system performed thefull and the busy signaling tests. Theresponse is answer, clear-back, re-answer or busy-flash.

SHORT BSY Variable Indicates the system performed theshort and the busy signaling tests.The response is answer or busy-flash.

MEAS Variable Gives the type of transmissionmeasurement the system performed

NONE Variable Indicates the system did not perform atransmission measurement

L Variable Indicates loss at base frequencymeasurement

LFD Variable Indicates loss frequency deviationmeasurement

N Variable Indicates noise measurement

378 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 379: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

L N Variable Indicates loss at base frequency andnoise measurement

LFD N Variable Indicates loss frequency deviation andnoise measurement

(msgtxt) Symbolic text Variable Gives additional informationconcerning the reason the test failed.Refer to table Q.

(CKT TTU n) 0-9 Variable Identifies the transmission test unit(TTU). The system only generates thisfield if the system uses TTUequipment in tests.

FAIL NBSY Constant Fixed Line test on an international circuitfails because the near end is busy(NBSY).

CKT Integers Variable Gives the common language locationidentifier (CLLI) and CKT number forthe trunk circuit.

DIR Constant Fixed Indicates that the fields that followcontain the results of directormeasurements. Tone originates atdistant office, measurements at nearoffice are examples of these results.

(BASE=+/-nn.n?/!) (+99.9dBm ?/!) to(-99.9dBm ?/!)

Variable Indicates the measured power level indBm, at 800hz or 1000hz, thatdeviates from the expected value.

+ indicates the level ishigher than thenominal - indicatesthat the level islower. ? indicates thatthe level exceeds theMaintenance Limits(Q1). ! indicates thatthe level exceeds theImmediate ActionLimits (Q2)..

Variable If a ? or an ! does not appear, thelevel does not exceed the limits. Thesystem presets the Q limits for trunktest position (TTP). The operatingcompany enters the Q limits forautomatic trunk testing (ATT) in TableATMEQ. Refer to the data schemasection of the Translations Guide foradditional information.

(400=+/-nn.n?/!) Refer to precedingvalue.

Variable Indicates the measured power level,as the power level deviates from thebase level. At this time, the frequencyof the signaling source is 400hz. Referto preceding description forexplanation of +/- and ?/!.

ATME205 379

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 380: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message example1.ATME205 JUN19 03:52:12 0462 FAIL NBSY

CKT N5LOOP 55

DIR: BASE= -1.1

RES: SIG: NONE

Clear message examplen/a

Associated OM registers

ATME206The Automatic Transmission Measuring Equipment (ATME) subsystemgenerates ATME206. The subsystem generates ATME206 when theConsultative Committee on International Telephony and Telegraphy(CCITT) ATME No.2 tests fail. The ATME No. 2 tests are applied to aninternational circuit. A test failure can indicate that the far end is busy.Each of the 25 test codes represents a group of signaling tests andtransmission measurements. The test code determines the tests that thesystem performs. The system does not generate all of the fields in thereport. The system denotes these fields as optional by ( ).

Remedial actionYou can use the RTSTFAIL command in ATME level at the MAP terminalto test the circuit again.

AttributesAttribute Value

Severity Indeterminate

Format1.ATME206 mmmdd hh:mm:ss ssdd FAIL FBSY

CKT trkid

DIR:BASE=+/-nn.n?/! 400=+/-nn.n?/! 2800=+/-nn.n?/! NOISE=+/-nn?/!

RES: =/-nn.n?/! =+/-nn.n?/! =+/-nn.n?/! =+/-nn?/!

tsttxt SIG: sigtxt MEAS: meastxt

380 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 381: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

msgtxt CKT TTU n

Selected field descriptionsField Value Fixed or

VariableDescription

FAIL FBSY Constant Fixed Indicates the system did not performline test on an international circuitbecause the far end is busy (FBSY).

CKT Symbolic text Variable Gives the common language locationidentifier (CLLI) and CKT number forthe trunk circuit.

DIR Constant Fixed Indicates that the fields following willcontain the results of directormeasurements. Tone originates atdistant office or measurement at nearoffice are examples of these results.

(BASE=+/-nn.n?/!) (+99.9dBm ?/!) to(-99.9dBm ?/!)

Variable Indicates the measured power level indBm, at 800hz or 1000hz, thatdeviates from the expected value.

+ indicates the level is higher than thenominal a indicates that the level islower.

? indicates that the level exceeds theMaintenance Limits (Q1)

indicates that the level exceeds theImmediate Action Limits (Q2)

If a ? or an ! is not present, the leveldoes not exceed the limits. The Qlimits are preset for trunk test position(TTP). The operating company entersthe Q limits for automatic trunk testing(ATT) in table ATMEQ. Refer to thedata schema section of theTranslations Guide for additionalinformation.

(400=+/-nn.n?/!) Refer to above. Variable Indicates the measured power level,as the power level deviates from thebase level. At this time, the frequencyof the signaling source is 400hz. Referto description above for explanation of+/- and ?/!.

(2800=+/-nn.n?/!) Refer to above. Variable Indicates the measured power level,as the power level deviates from thebase level. At this time, the frequency

ATME206 381

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 382: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

of the signaling source is 2800 hz.Refer to description above forexplanation of +/- and ?/!.

(NOISE= nn.n?/!) 0-90 Variable Indicates the measured noise level indBrn (phosphometric weighting).Refer to CCITT recommendations.The system stores Q limits againsteach circuit, in table CLLIMTCE. Referto the data schema section of theTranslations Guide for additionalinformation.

RES: Constant Fixed Indicates the following fields containthe results of respondermeasurements. The tone originates inthe near office or measurements atthe far office are examples of theresults..

(Base=+/-nn.n?/!) Variable Refer to DIR.

(400=+/-nn.n?/!) Variable Refer to DIR.

(2800=+/-nn.n?/!) Variable Refer to DIR.

(NOISE= nn?/!) Variable Refer to DIR.

(tsttxt) AN CB RA BF Variable Gives the response of a signaling test.The system only outputs results if thesystem performed a signaling test, asSIG field specifies.

AN Variable Indicates the system received ananswer.

CB Variable Indicates the system received a clear-back.

RA Variable Indicates the system received a re-answer.

BF Variable Indicates the system received a busy-flash.

SIG Variable Gives the type of signaling test thesystem performed.

NONE Variable Indicates the system did not performthe test.

FULL Variable Indicates the system performed a fullsignaling test. The response isanswer, clear-back or re-answer.

382 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 383: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

SHORT Variable Indicates the system performed ashort signaling test. The response isanswer.

BSY Variable Indicates the system performed abusy signaling test. The response isbusy-flash.

FULL BSY Variable Indicates the system performed a fulland the busy signaling tests. Theresponse is answer, clear-back, re-answer and busy-flash.

SHORT BSY Variable Indicates the system performed ashort and the busy signaling tests.The response is answer or busy-flash.

MEAS Variable Gives the type of transmissionmeasurement the system performed.

NONE Variable Indicates the system did not perform atransmission measurement.

L Variable Indicates loss at base frequencymeasurement.

LFD Variable Indicates loss frequency deviationmeasurement.

N Variable Indicates noise measurement.

L N Variable Indicates loss at base frequency andnoise measurement.

LFD N Variable Indicates loss frequency deviation andnoise measurement.

(msgtxt) Symbolic text Variable Gives additional information thatconcerns that concerns the reason thetest failed. Refer to table Q.

(CKT TTU n) 0-9 Variable Identifies the transmission test unit(TTU). The system only outputs thisfield if the system used TTUequipment in tests.

Active message example1.ATME206 JUN19 03:18:07 9000 FAIL FBSY

CKT N5LOOP 50

SIG:FULL MEAS: NONE

FAR_END_CONGESTION

ATME206 383

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 384: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

ATME207The Automatic Transmission Measuring Equipment (ATME) subsystemgenerates ATME207. The subsystem generates ATME207 when theConsultative Committee on International Telephony and Telegraphy(CCITT) ATME No. Two tests fail. The ATME No. Two tests are applied tointernational circuits. Instability or interruptions (I/I) cause a test failure.Each of the 25 test codes represents a group of signaling tests andtransmission measurements. The system performs different tests based onthe test code. The system does not generate all of the fields in this report.The system denotes these fields as optional by ( ).

There is no additional information

Remedial actionManually test the circuit to determine the cause of instability orinterruptions.

AttributesAttribute Value

Severity Indeterminate

Format1.*ATME207 mmmdd hh:mm:ss ssdd FAIL I/I

CKT trkid

DIR:BASE=+/-nn.n?/! 400=+/-nn.n?/! 2800=+/-nn.n?/! NOISE=+/-nn?/!

RES: =/-nn.n?/! =+/-nn.n?/! =+/-nn.n?/! =+/-nn?/!

tsttxt SIG: sigtxt MEAS: meastxt

msgtxt CKT TTU n

384 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 385: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

(400=+/-nn.n?/!) Refer to precedingvalue.

Variable Indicates the measured power level,as the power level deviates from thebase level. At this time, the frequencyof the signaling source is 400hz. Referto preceding description for +/-and ?/!.

(2800=+/-nn.n?/!) Refer to precedingvalue.

Variable Indicates the measured power level asthe power level deviates from thebase level. At this time, the frequencyof the signaling source is 2800 hz.Refer to preceding description for +/-and ?/!.

(NOISE= nn.n?/!) 0-90 Variable Indicates the measured noise level indBrn (phosphometric weighting, referto CCITT recommendations). Thesystem stores the Q limits againsteach circuit in table CLLIMTCE. Referto the data schema section of theTranslations Guide for additionalinformation.

RES: Constant Fixed Indicates that the following fieldscontain the results of respondermeasurements. Tone originates in thenear office or measurements at thedistant office are examples of theseresults.

(Base=+/-nn.n?/!) Variable Refer to DIR.

(400=+/-nn.n?/!) Variable Refer to DIR.

(2800=+/-nn.n?/!) Variable Refer to DIR.

(NOISE= nn?/!) Variable Refer to DIR.

(tsttxt) AN CB RA BF Variable Gives the response of a SignalingTest. The system only generates theresults if the system performs asignaling test, as field SIG fieldspecifies.

AN Variable Indicates the system received answer

CB Variable Indicates the system received clear-back

RA Variable Indicates the system received re-answer

ATME207 385

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 386: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

BF Variable Indicates the system received busy-flash

SIG Variable Gives the type of signaling test thesystem performed

NONE Variable Indicates the system did not performthe test

FULL Variable The system performed the fullsignaling test. The response isanswer, clear-back or re-answer.

SHORT Variable The system performed the shortsignaling test. The response isanswer.

BSY Variable The system performed the busysignaling test. The response is busy-flash.

FULL BSY Variable The system performed the full and thebusy signaling tests. The response isanswer, clear-back, re-answer orbusy-flash.

SHORT BSY Variable The system performed the short andthe busy signaling tests. The responseis answer or busy-flash.

MEAS Variable Gives the type of transmissionmeasurement performed

NONE Variable Indicates the system did not performtransmission measurement

L Variable Indicates loss at base frequencymeasurement

LFD Variable Indicates loss frequency deviationmeasurement

N Variable Indicates noise measurement

L N Variable Indicates loss at base frequency andnoise measurement

LFD N Variable Indicates loss frequency deviation andnoise measurement

(msgtxt) Symbolic text Variable Gives additional information on thereason the test failed. Refer to TableQ.

386 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 387: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

(CKT TTU n) 0-9 Variable Identifies the transmission test unit(TTU). The system only generates thisfield if the system uses TTUequipment in test.

DIR Constant Fixed Indicates that the following fieldscontain the results of directormeasurements. Tone originates atdistant office, and measurements atnear office are examples of theseresults.

(BASE=+/-nn.n?/!) (+99.9dBm ?/!) to(-99.9dBm ?/!)

Variable Indicates the measured power level indBm, at 800hz or 1000hz, thatdeviates from the expected value. +indicates the level is higher than thenominal. - indicates that the level islower. ? indicates that the levelexceeds the Maintenance Limits(Q1). ! indicates that the level exceedsthe Immediate Action Limits (Q2). Ifa ? or an ! is not present, the leveldoes not exceed the limits. Thesystem presets the Q limits for trunktest position (TTP). The operatingcompany enters the Q limits forautomatic trunk testing (ATT) in TableATMEQ. Refer to the data schemasection of the Translations Guide foradditional information.

FAIL I/I Constant Fixed Indicates instability or interruptionsthat occur during a test

CKT Symbolic text Variable Gives the common-language locationidentifier (CLLI) and CKT number forthe circuit.

Active message example1.ATME207 JUN19 03:32:10 3703 FAIL I/I

CKT N5LOOP 53

DIR: BASE= .

RES: .

AN SIG:NONE MEAS: L

ATME207 387

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 388: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

TTU_TROUBLE CKT TTU 1

Clear message examplen/a

Associated OM registers

ATME208The Automatic Transmission Measuring Equipment (ATME) subsystemgenerates this report when the Consultative Committee on InternationalTelephony and Telography (CCITT) ATME No. 2 tests fail. The systemapplies ATME No. 2 tests to international circuits. Detection of amiscellaneous error can cause the tests to fail. Each of the 25 test codesrepresents a group of signaling tests and transmission measurements. Thesystem performs different tests based on the test codes. The system doesnot generate some of the fields in the report, and denotes these fields asoptional by ().

There is no additional information

Remedial actionTest the circuit manually to determine source of error.

AttributesAttribute Value

Severity Indeterminate

Format*ATME208 mmmdd hh:mm:ss ssdd FAIL MISC

CKT trkid

DIR:BASE=+/-nn.n?/! 400=+/-nn.n?/! 2800=+/-nn.n?/! NOISE=+/-nn?/!

RES: =/-nn.n?/! =+/-nn.n?/! =+/-nn.n?/! =+/-nn?/!

tsttxt SIG: sigtxt MEAS: meastxt

msgtxt CKT TTU n

388 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 389: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

CKT Symbolic text Variable Gives the common-language locationidentifier (CLLI) and CKT number forthe circuit

DIR Constant Fixed Indicates that the following fieldscontain the results of directormeasurements. In other words, thetone starts at a distant office, and anear office measures the tone.

(BASE=+/-nn.n/!) (+99.9dBm ?/!) to(-99.9dBm ?/!)

Variable Indicates the measured power level indBm, at 800hz or 1000hz, thatdeviates from the expected value.

A (+) indicates the level is higher thanthe nominal.

A (-) indicates that the level is lowerthan nominal.

A (?) indicates that the level exceedsthe Maintenance Limits (Q1).

A (!) indicates that the level exceedsthe Immediate Action Limits (Q2).

If neither (?) or (!) appears, the leveldoes not exceed the limits. Thesystem sets the Q limits for trunk testposition (TTP). The operatingcompany enters the Q limits forautomatic trunk testing (ATT), in TableATMEQ. Refer to the data schemasection of the Translations Guide foradditional information.

(400=+/-nn.n?/!) Refer to previousvalue.

Variable Indicates the measured power level,as it deviates from the base level,when the frequency of the signalingsource is 400 hz. Refer to descriptionabove for explanation of (+)(-) and (?)(!)

(2800=+/-nn.n?/) Refer to previousvalue.

Variable Indicates the measured power level asit deviates from the base level, whenthe frequency of the signaling sourceis 2800 hz. Refer to description abovefor explanation of (+)(-) and (?)(!).

ATME208 389

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 390: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

(NOISE= nn.n?/!) 0-90 Variable Indicates the measured noise level indBrn. For phosphometric weighting,refer to CCITT recommendations. Thesystem stores the Q limits againsteach circuit in table CLLIMTCE. Referto the data schema section of theTranslations Guide for additionalinformation.

RES: Constant Fixed Indicates that the following fieldscontain the results of respondermeasurements. In other words, thetone originates at the near office. Thefar office performs measurements.

(Base=+/-nn.n?/!) Variable Refer to DIR.

(400=+/-nn.n?/!) Variable Refer to DIR.

(2800=+/-nn.n?/!) Variable Refer to DIR.

(NOISE= nn?/!) Variable Refer to DIR.

(tsttxt) AN CB RA BF Variable Gives the response of a signaling test.The system only generates the resultsif the system did a signaling test. Thesignal test is specified in field SIG.

AN Variable Indicates that the system received there-answer.

CB Variable Indicates that the system receivedclear-back.

RA Variable Indicates that the system received re-answer.

BF Variable Indicates that the system receivedbusy-flash.

SIG Variable Gives the type of signaling testperformed

NONE Variable Indicates the system did not performthe test

FULL Variable Indicates the system performed thefull signaling test. The response isanswer, clear-back, or re-answer.

SHORT Variable Indicates the system performed theshort signaling test. The response isanswer.

390 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 391: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

BSY Variable Indicates the system performed thebusy signaling test. The response isbusy-flash.

FULL BSY Variable Indicates the system performed thefull and the busy signaling tests. Theresponse is answer, clear-back, re-answer, and busy-flash.

SHORT BSY Variable Indicates the system performed theshort and the busy signaling tests.The response is answer or busy-flash.

MEAS Variable Gives the type of transmissionmeasurement performed

NONE Variable Indicates the system did not performtransmission measurement

L Variable Indicates loss at base frequencymeasurement

LFD Variable Indicates loss frequency deviationmeasurement

N Variable Indicates noise measurement

L N Variable Indicates loss at base frequency andnoise measurement

LFD N Variable Indicates loss frequency deviation andnoise measurement

(msgtxt) See Table Q. Variable Gives additional information for whythe test failed

(CKT TTU n) 0-9 Variable Identifies the transmission test unit(TTU). The system only generates thisfield if the TTU equipment is in use forthe test.

FAIL MISC Constant Fixed Indicates that a miscellaneous errorcaused test failure.

Active message example1.ATME208 JUN19 03:32:10 3703 FAIL MISC

CKT N5LOOP 53

DIR: BASE= .

RES: .

ATME208 391

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 392: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AN SIG:NONE MEAS: L

TTU_TROUBLE CKT TTU 1

Clear message examplen/a

Associated OM registers

ATT100The Automatic Trunk Testing (ATT) subsystem generates this report whena trunk circuit test completes. Log ATT100 reports miscellaneous trunkcircuit test results not in other ATT log reports.

There is no additional information

Remedial actionIf rslttxt = PASS, there is no required action.

If rslttxt = FAIL, contact the next level of maintenance.

AttributesAttribute Value

Severity Warning

Format1.ATT100 mmmdd hh:mm:ss ssdd INFO

CKT trkid

tstnm rslttxt

Selected field descriptionsField Value Fixed or

VariableDescription

INFO Constant Fixed Indicates the following data providesmiscellaneous trunk circuit test results

CKT Symbolic text Variable Provides equipment identification forsuspect trunk equipment

tstnm DIAG Variable Indicates system performed anextended diagnostic test

392 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 393: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TCON Variable Indicates system performed CommonChannel Interoffice Signaling No. 6(CCIS6) continuity test

TCOT Variable Indicates system performed a newversion of CCIS6 continuity test on adigital trunk controller (DTC)

TE_M Variable Indicates system performed E and Mlead signaling test

TNSS Variable Indicates system performed non-synchronous test line test

tstnm TR2L Variable Indicates system performed "repeattwo" long delay test

TR2S Variable Indicates system performed "repeattwo" short delay test TSYN Indicatessystem performed synchronous testline test

T103 Variable Indicates system used 103-type testline to perform signaling test

rslttxt PASS Variable Indicates test passed

FAIL Variable Indicates test failed

Active message example1.ATT100 APR01 12:00:00 2112 INFO

CKT CAMA2W 1

DIAG PASS

Clear message examplen/a

Associated OM registers

ATT101The Automatic Trunk Testing (ATT) subsystem generates this report whena group trunk test aborts.

Remedial actionIf the above table contains reastxt, use the following references to isolateand correct failures. ATT101 specifies these references.

ATT101 393

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 394: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

For failures related to entries, refer to the data schema section of theTranslations Guide. For trunk equipment failures, refer to CardReplacement Procedures. This is a step-by-step procedures guide toisolate and correct trunk and test equipment failures. For more informationabout trunk testing, refer to the Trunks Maintenance Guide.

If the generated reastxt is not in the above table, contact the next level ofmaintenance.

AttributesAttribute Value

Severity Warning

FormatATT101 mmmdd hh:mm:ss ssdd INFO

CKT trkid

ABORT GROUP TESTING TESTEQ: trkid tstnm ABORT

reastxt

Selected field descriptionsField Value Fixed or

VariableDescription

TL6N Variable Indicates system used 105-type testline to perform loss (404, 1004, and2804 Hz at -16 dBm) and noise(C_notched filter) test

TL6S Variable Indicates system used 105-type testline to perform loss (404, 1004, and2804 Hz at -16 dBm) and test with selfcheck

TL65 Variable Indicates system used 105-type loss(404, 1004, and 2804 Hz at -16 dBm)test

TL05 Variable Indicates system used 105-type testline to perform loss (1004 Hz at zerodBm) test

TNSS Variable Indicates system performed non-synchronous test line test

TR2L Variable Indicates system performed two longdelay repeat tests

394 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 395: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TR2S Variable Indicates system performed two shortdelay repeat tests

TSBS Variable Indicates the far-end equipmentperformed a self check of loss (404,1004, and 2804 Hz test tone at -16dB), noise (C_notched filter). Thesystem used a 105-type test line toperform a return loss test.

TSBT Variable Indicates the system performed returnloss measurement test

TSYN Variable Indicates the system performedsynchronous test line test

TS65 Variable Indicates the far-end equipment used105-type test line to perform selfcheck of loss (404, 1004, and 2804 Hztest tone at -16 dB) and noise(C_notched filter).

T100 Variable Indicates the system used 100-typetest line to perform milliwatt andbalance test. The versions are notknown.

T102 Variable Indicates the system used 102-typetest line to perform milliwatt test

T103 Variable Indicates the system used 103-typetest line to perform signaling test

T104 Variable Indicates the system used 104-typetest line to perform milliwatt test inboth directions

T105 Variable Indicates the system used 105-typetest line to perform loss (1004 Hz at 0dBm) and noise (C_message filter)tests with self check

T165 Variable Indicates system used 105-type testline to perform loss (404, 1004, and2804 Hz at - 16 dBm) and noise(C_notched filter) tests with self check

T5AS Variable Indicates the system used 105-typetest line to perform loss (1004 Hz at 0dBm), noise (C_message filter), andreturn loss tests with self check

ATT101 395

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 396: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

T5AT Variable Indicates the system used 105-typetest line to perform loss (C1004 Hz at0 dBm), noise (C_message filter), andreturn loss (C1004 Hz at 0 dBm) tests

T5LB Variable Indicates the system used 105-typetest line to perform loss (404, 1004,and 2804 Hz at -16 dBm) and returnloss test

T5SB Variable Indicates the system used 105-typetest line to perform return loss testwith self check

T50L Variable Indicates the system used 105-typetest line to perform loss (1004 Hz at 0dBm) and return loss (C1004 Hz at 0dBm) tests

T56N Variable Indicates the system used 105-typetest line to perform loss (404, 1004,and 2804 Hz at -16 dBm), noise(C_notched filter), and return losstests

ABORT Constant Fixed Indicates test did not complete

reastxt ACTIVE TABLE FULL Variable Indicates the system attempted to runmore trunk tests at one time than theset entry in table ATTSCHED allows.Table ATTSCHED is a customer datatable

ACTION: Change number of testsallowed at a time. Perform this changeat ATT MAP level

BUSY TONE Variable Indicates far-end office returned abusy tone

ACTION: Try test again.

CARD FAULT Variable Indicates circuit pack meets hardwarefault

ACTION: Replace circuit pack

CONNECTIONFAILURE

Variable Indicates connection failure betweentrunk and test equipment

ACTION: Diagnose trunk testequipment

396 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 397: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

COULD NOT OPENATTOPTNS

Variable Indicates software bug did not allowuser to access customer data tableATTOPTNS

ACTION: Try test again.

COULD NOT READATTOPTNS

Variable Indicates required entry in customerdata. ATTOPTNS Table does nothave entries for specified test class.

ACTION: Check trunk and testparameters and options. Retry test

CSC MTCE INPROGRESS

Variable The system attempts to perform acellular trunk test during maintenanceof cell site controller (CSC)

ACTION: Try test again

DATA FAULT Variable Indicates system has problems withreceived test result data

ACTION: Retry test

DIAGNOSTIC NOTALLOWED

Variable Indicates test initiates on circuit notequipped for that test type

ACTION: Check trunk and testparameters and options.

DIAL TONE Variable Indicates far-end office returned dialtone

ACTION: Try test again

FACILITY FAULT Variable Indicates fault in transmission facilities

ACTION: Diagnose trunk and testequipment

FAILED TO RUNDIAGNOSTIC

Variable Indicates test equipment is notavailable or is inoperative

ACTION: Diagnose trunk and testequipment

FAILED TO RUNTESTLINE

Variable Indicates software bug during initialsetup prevents test. Normallyindicates processes are not available

ACTION: Try test again

ATT101 397

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 398: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

GROUPCURRENTLYUNDER TEST

Variable Indicates trunk group executed a trunktest and the system ignored thesecond test request

ACTION: No action is required

GROUP MANUALABORT

Variable Indicates user aborted the testmanually from the ATT MAP level. Tomanually abort a test, the user can:

• Explicitly stop a group test

• Reduce number of tests ATT canexecute at the same time

• Stop all ATT tests (HaltATT)

ACTION: No action is required

GROUP SYSTEMABORT:REFERENCE TRUNKFAILURE

Variable The system meets five consecutivefailures and retests the referencetrunk. The reference trunk fails thenext test and the group aborts.

ACTION: Diagnose trunk testingequipment and reference trunks.

MXAM Variable Indicates system performed mobiletelephone exchange (MTX) audio looptest with C-message filter

MXAN Variable Indicates system performed MTXaudio loop test with C-notch filter

MXRM Variable Indicates system performed MTXradio frequency loop test with C-message filter

MXRN Variable Indicates system performed MTXradio frequency loop test with C-notchfilter

MXWM Variable Indicates system performed MTX wireloop test with C-message filter

MXWN Variable Indicates system performed MTX wireloop test with C-notch filter

N100 Variable Indicates system used 100-type testline to perform new version of milliwattand balance test

398 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 399: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

S100 Variable Indicates system used 100-type testline to perform old version of balancetest

TART Variable Indicates system performed turkeyarter test line test

TA01 Variable Indicates system used automatictransmission measuring equipment(ATME) tp perform transmission testof level measurements in bothdirections

TA02 Variable Indicates system used ATME toperform transmission test of lossfrequency deviation

TA03 Variable Indicates system used ATME toperform transmission test of noisemeasurements

TA04 Variable Indicates system used ATME toperform transmission test of levelmeasurements in both directions andnoise measurements

TA05 Variable Indicates system used ATME toperform transmission test of lossfrequency deviation and noisemeasurement

TA06 Variable Indicates system used ATME toperform full signaling test

TESTEQ Symbolic text Variable Identifies test equipment for group test

tstnm DIAG Variable Indicates system performed extendeddiagnostic test

TRUNK NOTTESTED SB

Variable Indicates the system did not test trunkcircuit because trunk circuit wassystem busy

ACTION: Contact the next level ofmaintenance.

TRUNK NOTTESTED

Variable Indicates the system did not test trunkcircuit SZD because the systemalready seized the trunk circuit

ACTION: When trunk state returns toIDLE, try test again.

ATT101 399

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 400: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TRUNK TIMEOUT Variable Indicates waiting time expired forseparate trunks to become availablefor test. The time allowed for trunks tobecome available is in customer datatable ATTSCHED.

ACTION: Check WAIT_TIME incustomer data table ATTSCHED. Trytest.

TST EQUIPMENTNOT

Variable Indicates difference REQUIRED inrequested test. The requested testcalls for equipment that is notnecessary.

ACTION: Check trunk and testparameters and options.

TTU FAULT Variable Indicates the system found a fault inthe transmission test unit (TTU)

ACTION: Diagnose TTU.

UNEXPECTED TONE Variable Indicates far-end office returns tonesthat the system does not expect toknow.

ACTION: Diagnose trunk testequipment.

UNKNOWN ATTMESSAGE

Variable Indicates software bug. A softwareerror (SWER) report follows thismessage.

ACTION: Contact the next level ofmaintenance.

WRONG CARD INSHELF

Variable Indicates wrong circuit pack is in theshelf

ACTION: Check trunk circuitequipment installation.

120 IPM TONE Variable Indicates far-end office returned asignal at 120 impulses per minute

ACTION: Try test again.

516 30 IPM TONE Variable Indicates far-end office returned asignal at 30 impulses per minute

400 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 401: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Try test again.

logtxt FAIL Variable Indicates trunk test failed. Displayedwith all reasons except TESTEQUIPMENT NOT AVAILABLE andTRUNK NOT TESTED.

SKIP Variable Indicates the system skipped a trunktest. This value appears with TRUNKNOT TESTED reason only.

TESTEQ Variable Indicates test equipment is notavailable. This value appears withTEST EQUIPMENT UNAVAILABLEreason only.

TA07 Variable Indicates system used ATME toperform full signaling test andtransmission test of levelmeasurements in both directions

TA08 Variable Indicates system used ATME toperform full signaling test andtransmission test of loss frequencydeviation

TA09 Variable Indicates system used ATME toperform full signaling test andtransmission test of noisemeasurements

TA10 Variable Indicates system used ATME toperform full signaling test andtransmission test of levelmeasurements in both directions andnoise measurements

TA11 Variable Indicates system used ATME toperform full signaling test andtransmission test of loss frequencydeviation and noise measurements

TA12 Variable Indicates system used ATME toperform short signaling test

TA13 Variable Indicates system used ATME toperform busy flash signaling test

TA14 Variable Indicates system used ATME toperform busy flash signaling test andtransmission test of levelmeasurements in both directions

ATT101 401

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 402: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TA15 Variable Indicates system used ATME toperform busy flash signaling test andtransmission test of loss frequencydeviation

TA16 Variable Indicates system used ATME toperform busy flash signaling test andtransmission test of noisemeasurements

TA17 Variable Indicates system used ATME toperform busy flash signaling test andnoise measurements andtransmission test of levelmeasurements in both directions

TA18 Variable Indicates system used ATME toperform busy flash signaling test andtransmission test of loss frequencydeviation and noise measurements

TA19 Variable Indicates system used ATME toperform full signaling test and busyflash signaling test

TA20 Variable Indicates system used ATME toperform full signaling test, busy flashsignaling test, and transmission test oflevel measurements in both directions

TA21 Variable Indicates system used ATME toperform full signaling test, busy flashsignaling test, and transmission test ofloss frequency deviation

TA22 Variable Indicates system used ATME toperform full signaling test, busy flashsignaling test, and transmission test ofnoise measurements

TA23 Variable Indicates system used ATME toperform full signaling test, busy flashsignaling test, and transmission test oflevel measurements and noisemeasurements in both directions

TA24 Variable Indicates system used ATME toperform full signaling test busy flashsignaling test, and transmission test ofnoise measurements and lossfrequency deviation

402 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 403: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TA25 Variable Indicates system used ATME toperform short signaling test and busyflash signaling test

TCON Variable Indicates system performed CCIS6continuity test

TCOT Variable Indicates system performed CCIS6continuity test (new version on DTC)

TE_M Variable Indicates system performed E and Mlead signaling test

TLPA Variable Indicates system performed loop-around test line test. Reference trunkoccupies port one transmission testtrunk (TTT)

TLPB Variable Indicates system performed loop-around test line test. Reference trunkoccupies port two TTTs

TL0N Variable Indicates system used 105-type testline to perform loss (1004 Hz at zerodBm) and noise (C_message filter)test

TL0S Variable Indicates system used 105-type testline to perform loss (1004 Hz at zerodBm) test with self check

GROUP SYSTEMABORT:REFERENCE TRUNKNOT AVAILABLE

Variable The system encounters fiveconsecutive failures and retests thereference trunk. The reference trunkwas not seized. The group systemaborts.

ACTION: Diagnose trunk testingequipment and reference trunks.

GROUP SYSTEMABORT: 5CONSECUTIVEFAILURES

Variable The system meets five failures oneafter the other in a search for a groupreference trunk

ACTION: Diagnose trunk testequipment.

HARDWAREFAILURE

Variable Indicates the system detectedhardware fault in the trunk circuit

ACTION: Diagnose tested trunk. Thetrunk can have a hardware fault.

ATT101 403

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 404: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

HIGH - DRY Variable Indicates far-end office did not sendan off-hook signal after a burst ofaudible ringing tone

ACTION: Diagnose tested trunk. Ifdiagnostics pass, fault is in far-end ortransmission facility.

HIGH TONE Variable Indicates far-end office returned ahigh frequency tone

ACTION: Try test again.

HIT RECEIVED Variable Indicates the system detects transientcondition on the trunk

ACTION: Try test again.

INVALID REPLY Variable Indicates far-end office returns asignal that is not correct when theDMS attempts to transmit digits

ACTION: Diagnose trunk under test. Ifdiagnostics pass, fault is in far-end ortransmission facility.

LOOP SIG FAULT Variable Indicates signaling failure caused by afault in either the loop bridge orreceiving equipment

ACTION: Diagnose test equipment.

LOOP SIG FAULTNO SET

Variable Indicates signaling failure that a faultin the software or loop generatingequipment cause

ACTION: Check trunk and testparameters and options. Diagnosetest equipment.

LTA CANCELLED Variable Indicates local trunk alarm (LTA) wasnot cancelled correctly

ACTION: Diagnose test equipmentand try test again.

LTU FAULT Variable Indicates the system detects faults inline test unit (LTU)

ACTION: Diagnose LTU.

404 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 405: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

MILLIWATT Variable Indicates far-end office returned amilliwatt tone

ACTION: Try test again.

NO/BAD CSCRESPONSE

Variable Indicates the system attempts toperform a cellular trunk test. Thesystem received either no responsesor a response that the system did notexpect from the CSC.

ACTION: Diagnose CSC.

NO/BAD TAURESPONSE

Variable Indicates the system attempts toperform a cellular trunk test. Thesystem receives no response or aresponse that the system does notexpect. The response is from thecellular remote carrier unit (RCU).

ACTION: Diagnose RCU.

NO/BAD TAU perform Variable Indicates the system attempts to aRESPONSE cellular trunk test. Thesystem receives no response or aresponse that the system does notexpect. The system receives theresponse from the cellular test andalarm unit (TAU).

ACTION: Diagnose TAU.

NO CARD IN SHELF Variable Indicates circuit pack was not present

ACTION: Check trunk circuitequipment installation.

NO FAR END TESTEQUIPMENT

Variable Indicates far-end test equipment wasnot available or not present

ACTION: Diagnose tested trunk. Ifdiagnostics pass, fault is in far-end ortransmission facility.

NO LOGICAL MB Variable Indicates software bug does notprevent the system from allocating alogical message buffer (MB)

ACTION: Try test again.

ATT101 405

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 406: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

NO START DIALSIGNAL

Variable Indicates far-end office did notrespond after system seized trunk

ACTION: Try test again.

NO TESTEQUIPMENT

Variable Indicates test equipment was notavailable

ACTION: Check trunk and testparameters and options.

NO TESTLINENUMBER

Variable Indicates software bug did not allowsystem to find trunk circuit

ACTION: Check trunk and testparameters and options. Try testagain.

NO TONE Variable Indicates far-end office did not returnthe correct tone

ACTION: Try test again.

NO TRUNKS INGROUP

Variable Indicates software bug does not allowsystem to find group trunks

ACTION: Check trunk and testparameters and options. Try testagain.

NOT OG OR 2WTRUNK GROUP

Variable Indicates test attempts transmission orloss tests on an out-going or two-wiretrunk

ACTION: Check trunk and testparameters and options.

OUTPULSINGTROUBLE

Variable Indicates the system has trouble whensystem transmits digits

ACTION: Diagnose tested trunk. Ifdiagnostics pass, fault is in far-end ortransmission facility.

OVERFLOW TONE Variable Indicates far-end office returned anoverflow tone

ACTION: Try test again.

PARAMETER FAULT Variable Indicates parameters were not corrector not correct for test type

406 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 407: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Check trunk and testparameters and options.

PERIODIC SIGNAL Variable Indicates far-end office returned asignal at intervals

ACTION: Try test again.

PM FAULT Variable The system meets a fault in theperipheral module (PM)

ACTION: Diagnose PM.

RECORDEDANNOUNCEMENT

Variable Indicates far-end office returned arecorded announcement

ACTION: Try test again.

REORDER TONE Variable Indicates far-end office returned areorder tone

ACTION: Try test again.

RINGING Variable Indicates far-end office did notrespond to ringing

ACTION: Diagnose tested trunk. Ifdiagnostics pass, fault is in far-end ortransmission facility.

STOP DIAL SIGNALRECEIVED

Variable Indicates far-end office returned acongestion signal when officetransmitted digits

ACTION: Try test again.

TAU NOTAVAILABLE

Variable Indicates the system attempts toperform a cellular trunk test. The testand alarm unit was not in use or wasnot available

ACTION: Try test again.

TEST EQUIPMENTFAIL

Variable Indicates the system detects fault intest equipment

ACTION: Diagnose trunk testequipment.

TEST EQUIPMENTFAULT

Variable The system detects fault in testequipment

ATT101 407

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 408: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Diagnose trunk testequipment.

TEST EQUIPMENTUNAVAILABLE

Variable Indicates test equipment was notavailable for test. The systemgenerates this report every tenminutes if test equipment is notavailable.

ACTION: Action is not required.

TEST NOTALLOWED

Variable Indicates test is not allowed on circuit

ACTION: Check trunk and testparameters and options.

TEST PROCESSTROUBLE

Variable The system encounters trouble withtest TROUBLE process

ACTION: Try test again.

TEST PROTOCOLTROUBLE

Variable Indicates the system detects asoftware bug or TROUBLE the systemreceived a response that the systemdid not expect from far-end office

ACTION: Try test again.

TESTLINE NOTAVAILABLE

Variable Indicates test is not available incurrent load

ACTION: Check trunk and testparameters and options.

TONE DETECTIONFAILED

Variable Indicates failure to detect correct tone

ACTION: Diagnose trunk testequipment.

TPT TONE Variable Indicates far-end office returned a testprogress tone (TPT) that the systemdid not expect

ACTION: Try test again.

TRUNK GROUPTIMEOUT

Variable Indicates time expired for separatetrunks in a trunk group to becomeavailable for testing. The time allowedfor available trunks is to becomeavailable in customer data TableATTSCHED.

408 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 409: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Check WAIT_TIME incustomer data Table ATTSCHED.Retry test.

TRUNK NOTTESTED CFL

Variable Indicates system did not test trunkcircuit because trunk circuit wascarrier failed

ACTION: Contact the next level ofmaintenance.

TRUNK NOTTESTED CPD

Variable Indicates system did not test trunkcircuit because trunk circuit was callprocessing deloaded

ACTION: When trunk state returns toIDLE, try test again.

TRUNK NOTTESTED CPB

Variable Indicates system did not test trunkcircuit because trunk circuit was callprocessing busy

ACTION: When trunk state returns toIDLE, try test again.

TRUNK NOTTESTED DEL

Variable Indicates system did not test trunkcircuit because trunk circuit wasdeloaded

ACTION: Return trunk to service, trytest again.

TRUNK NOTTESTED IMB

Variable Indicates the system did not test trunkcircuit because trunk circuit was offline

ACTION: Return trunk to service, trytest again.

TRUNK NOTTESTED INI

Variable Indicates the system did not test trunkcircuit because trunk circuit wasinitialized

ACTION: Return trunk to service, trytest again.

TRUNK NOTTESTED LO

Variable Indicates the system did not test trunkcircuit because trunk circuit waslocked out

ACTION: Contact the next level ofmaintenance.

ATT101 409

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 410: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TRUNK NOTTESTED MB

Variable Indicates the system did not test trunkcircuit because trunk circuit wasmanually busy

ACTION: Return trunk to service, trytest again.

TRUNK NOTTESTED NEQ

Variable Indicates the system did not test trunkcircuit because trunk circuit was notequipped

ACTION: Return trunk to service, trytest again.

TRUNK NOTTESTED NMB

Variable Indicates the system did not test trunkcircuit because trunk circuit wasnetwork management busy

ACTION: When trunk state returns toIDLE, try test again.

TRUNK NOTTESTED PMB

Variable Indicates the system did not test trunkcircuit because trunk circuit wasperipheral module busy

ACTION: Contact the next level ofmaintenance.

TRUNK NOTTESTED RES

Variable Indicates the system did not test trunkcircuit because trunk circuit was inrestricted idle

ACTION: When trunk state returns toIDLE, try test again.

TRUNK NOTTESTED RMB

Variable Indicates the system did not test trunkcircuit because trunk circuit wasremote busy

ACTION: Contact the next level ofmaintenance.

INFO Constant Fixed Indicates the following data provides areport when a group trunk test aborts

CKT Symbolic text Variable Provides equipment identification forsuspect trunk equipment

ABORT GROUPTESTING

Constant Fixed Indicates test is not complete

410 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 411: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleATT101 APR01 12:00:00 2112 INFO

CKT trkid

ABORT GROUP TESTING TESTEQ: TTT 0 DIAG ABORT

COULDN''T READ ATTOPTNS

Clear message examplen/a

Associated OM registers

ATT102The Automatic Trunk Testing (ATT) subsystem report ATT102. Thesubsystem generates ATT102 when a trunk test fails or does not complete.

Remedial actionIf you find reastxt in the preceding table, use the following references toisolate and correct failures that ATT101 indicates.

For failures related to data entry, refer to the data schema section of theTranslations Guide. For failures related to trunk equipment, refer to CardReplacement Procedures. This document gives step-by-step procedures toisolate and correct trunk and test equipment failures. For more informationconcerning trunk testing, refer to the Advanced Maintenance Guide.

If you do not find reastxt generated in the table above, contact the nextlevel of support.

AttributesAttribute Value

Severity Warning

FormatATT102 mmmdd hh:mm:ss ssdd INFO

CKT trkid

tstnm reastxt rslttxt

ATT102 411

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 412: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

T102 Variable Indicates that the system used a 102-type test line to perform the milliwatttest.

T103 Variable Indicates that the system used a 103-type test line to perform a signalingtest.

T104 Variable Indicates that the system used a 104-type test line to perform a milliwatt testin both directions.

TRUNK NOTTESTED RMB

Variable Indicates that the system did not testthe trunk circuit because the circuitwas remote busy.

ACTION: Contact the next level ofmaintenance.

TRUNK NOTTESTED SB

Variable Indicates that the trunk circuit was nottested because it was system busy.

ACTION: Contact the next level ofmaintenance.

TRUNK NOTTESTED SZD

Variable Indicates that the system did not testthe trunk circuit because the circuitwas already seized.

ACTION: When the trunk returns tothe IDLE state, try test again.

ACTION: When trunk returns to theIDLE state, try test again.

TRUNK TIMEOUT Variable Indicates the amount of time eachtrunk waits for a test. The allowedwaiting time is in the customer dataTable ATTSCHED.

ACTION: Check WAIT_TIME in thecustomer data Table ATTSCHED. Trytest again.

TST EQUIPMENTNOT REQUIRED

Variable Indicates a difference in the requestedtest. The requested test called forequipment that was not necessary.

ACTION: Check the trunk and test theparameters and options.

412 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 413: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TTU FAULT Variable Indicates a defect found in thetransmission test unit (TTU).

ACTION: Diagnose TTU.

UNEXPECTED TONE Variable Indicates that the far-end officereturned a tone that is not planned ornot known.

ACTION: Diagnose trunk testequipment.

UNKNOWN ATTMESSAGE

Variable Indicates a software bug is present. ASoftware Error Report (SWER) alwaysprecedes this message.

ACTION: Contact the next level ofmaintenance.

WRONG CARD INSHELF

Variable Indicates a wrong circuit pack installedin the shelf.

ACTION: Check the trunk circuitequipment installation.

120-IPM TONE Variable Indicates that a far-end office returneda signal at 120 impulses every minute.

ACTION: Try test again.

30-IPM TONE Variable Indicates that a far-end office returneda signal at 30 impulses every minute.

ACTION: Try test again.

logtxt FAIL Variable Indicates that a trunk test failed.These results are displayed with allreasons except TEST EQUIPMENTUNAVAILABLE and TRUNK NOTTESTED.

T105 Variable Indicates that the system performed aloss (1004 Hz at 0 dBm) and noise(C_message filter) test automatically.Indicates the system used a 105-typetest line.

T165 Variable Indicates that the system performed aloss (404, 1004, and 2804 Hz at -16dBm) and noise (C_notched filter) testautomatically. Indicates the systemused a 105-type test line.

ATT102 413

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 414: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

T5AS Variable Indicates that the system performed aloss (1004 Hz at 0 dBm), a noise(C_message filter), and a return losstest automatically. Indicates thesystem used 105-type test line.

T5AT Variable Indicates the system performed twotests. A loss (C1004 Hz at 0 dBm),noise (C_message filter), and returnloss (C1004 Hz at 0 dBm) test.Indicates the system used 105-typetest line.

T5BS Variable Indicates that the system performed areturn loss measurement and self-check test. Indicates the system useda 105-type test line.

T5LB Variable Indicates that the system performed aloss (404, 1004, and 2804 Hz at -16dBm) and return loss test. Indicatesthe system used a 105-type test line.

T5SB Variable Indicates that the system used a 105-type test line to perform a return losstest with self-check.

T50L Variable Indicates that the system performed aloss (1004 Hz at 0 dBm) and returnloss (C1004 Hz at 0 dBm) test.Indicates the system used a 105-typetest line.

T56N Variable Indicates that the system performed aloss (404, 1004, and 2804 Hz at -16dBm), noise (C_notched filter), andreturn loss test. Indicates the systemused a 105-type test line.

ACTIVE TABLE FULL Variable Indicates that the system called moretrunk tests to execute than the presentsetting in customer data TableATTSCHED permits.

ACTION: Change number ofsimultaneous tests from ATT MAPlevel.

BUSY TONE Variable Indicates that far-end office returns abusy tone.

ACTION: Try test again.

414 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 415: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

CARD FAULT Variable Indicates there is a hardware fault incircuit pack.

ACTION: Replace circuit pack.

CONNECTIONFAILURE

Variable Indicates there is a connection failurebetween the trunk and the testequipment.

ACTION: Diagnose trunk testequipment.

COULDN'T OPENATTOPTNS

Variable Indicates that a software bugprevented the opening of or access tocustomer data Table ATTOPTNS.

ACTION: Try test again.

COULDN'T READATTOPTNS

Variable Indicates that the required entry in thecustomer data Table ATTOPTNS isnot present for a specified test class.

ACTION: Check trunk and testparameters and options. Try testagain.

CSC MTCE INPROGRESS

Variable Indicates that the system attempted toperform a cellular trunk test while themaintenance of a cell site controller(CSC) was in progress.

ACTION: Try test again.

DATA FAULT Variable Indicates that trouble occurred withthe received test result data.

ACTION: Try test again.

DIAGNOSTIC NOTALLOWED

Variable Indicates that a test initiated on acircuit not equipped for that test type.

ACTION: Check trunk and testparameters and options.

DIAL TONE Variable Indicates that the far-end officereturned the dial tone.

ACTION: Try test again.

FACILITY FAULT Variable Indicates a defect in transmissionfacilities.

ATT102 415

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 416: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Diagnose trunk and testequipment.

FAILED TO RUNDIAGNOSTIC

Variable Indicates that test equipment is notavailable or not operational.

ACTION: Diagnose trunk and testequipment.

FAILED TO RUNTESTLINE

Variable Indicates that a software bugprevented the performance of the test.The software performs the first setup.This field value normally indicates thatno processes are available.

ACTION: Try test again.

GROUPCURRENTLYUNDER TEST

Variable Indicates that the trunk groupexecuted a trunk test and ignored thesecond test request.

ACTION: No required action.

GROUP MANUALABORT

Variable Indicates that the test abortedmanually from the ATT MAP level.The operating company personnel:

• stopped group test.

• reduced number of simultaneoustests the ATT can execute.

• Stopped all ATT tests (HaltATT).

ACTION: No required action.

SKIP Variable Indicates that a trunk test wasskipped. Displayed with TRUNK NOTTESTED reason only.

TESTEQ Variable Indicates that the test equipment isnot available. Displayed with TESTEQUIPMENT UNAVAILABLE reasononly.

GROUP SYSTEMABORT:REFERENCE TRUNKFAILURE

Variable Indicates that the system encountersfive consecutive failures and tests thereference trunk again. The referencetrunk failed the test that followed andthe system aborted the group.

ACTION: Diagnose trunk testingequipment and reference trunks.

416 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 417: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

INFO Constant Fixed Indicates the data that follows reportswhen a trunk test fails or does notcomplete.

CKT Symbolic text Variable Provides equipment identificationsuspect trunk equipment.

tstnm DIAG Variable Indicates that the system performedan extended diagnostic test.

MXAM Variable Indicates that a mobile telephoneexchange (MTX) audio loop test withC-message filter was performed.

MXAN Variable Indicates that the system performedan MTX audio loop test with C-notchfilter.

MXRM Variable Indicates that the system performedan MTX radio frequency loop test withC-message filter.

MXRN Variable Indicates that the system performedan MTX radio frequency loop test withC-notch filter.

MXWM Variable Indicates that the system performedan MTX wire loop test with C-message filter.

MXWN Variable Indicates that the system performedMTX wire loop test with C-notch filter.

N100 Variable Indicates that the system performed anew version of milliwatt and balancetest. Indicates the system used a 100-type test line.

S100 Variable Indicates that the system used 100-type test line to perform only an oldversion of a balance test.

TART Variable Indicates that the system performed aTurkey arter test line test.

TA01 Variable Indicates that the system performed atransmission test of levelmeasurements in both directions.Indicates the system used anautomatic transmission measuringequipment (ATME).

TA02 Variable Indicates that the system used ATMEto perform a transmission test of lossfrequency deviation.

ATT102 417

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 418: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TA03 Variable Indicates that the system used ATMEto perform a transmission test of noisemeasurements.

TA04 Variable Indicates that the system used ATMEto perform a transmission test of levelmeasurements in both directions andnoise measurements.

TA05 Variable Indicates that the system used ATMEto perform a transmission test of lossfrequency deviation and noisemeasurements.

TA06 Variable Indicates that the system used ATMEto perform a full signaling test.

TA07 Variable Indicates that the system used ATMEto perform a full signaling test andtransmission test of levelmeasurements in both directions.

TA08 Variable Indicates that the system used ATMEto perform a full signaling test andtransmission test of loss frequencydeviation.

TA09 Variable Indicates that the system used ATMEto perform a full signaling test andtransmission test of noisemeasurements.

TA10 Variable Indicates that the system used ATMEto perform a full signaling test. Thesystem used ATME to perform atransmission test of levelmeasurements in both directions, andnoise measurements.

TA11 Variable Indicates the system used ATME toperform a full signaling test andtransmission test of loss frequencydeviation and noise measurements.

TA12 Variable Indicates the system used ATME toperform a short signaling test.

TA13 Variable Indicates the system used ATME toperform a busy flash-signaling test.

TA14 Variable Indicates the system used ATME toperform a busy flash-signaling testand transmission test of levelmeasurements in both directions.

418 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 419: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TA15 Variable Indicates that the system used ATMEto perform a busy flash- signaling testand a transmission test of lossfrequency deviation.

TA16 Variable Indicates that the system used ATMEto perform a busy flash-signaling testand transmission test of noisemeasurements.

TA17 Variable Indicates that the system used ATMEto perform a busy flash-signaling test.The system used ATME to perform atransmission test of levelmeasurements in both directions, andnoise measurements.

TA18 Variable Indicates that the system used ATMEto perform a busy flash-signaling test.The system used ATME to perform atransmission test of loss frequencydeviation and noise measurements.

TA19 Variable Indicates that the system used ATMEto perform a full signaling test andbusy flash-signaling test.

TA20 Variable Indicates that the system used ATMEto perform a full signaling test. Thesystem used ATME to perform a busyflash-signaling test, and atransmission test of levelmeasurements in both directions.

TA21 Variable Indicates that the system used ATMEto perform a full signaling test. Thesystem used ATME to perform a busyflash-signaling test, and atransmission test of loss frequencydeviation.

TA22 Variable Indicates that the system used ATMEto perform a full signaling test. Thesystem used ATME to perform a busyflash-signaling test, and atransmission test of noisemeasurements.

TA23 Variable Indicates that the system used ATMEto perform a full signaling test. Thesystem used ATME to perform a busy

ATT102 419

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 420: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

flash-signaling test, a transmissiontest of level measurements in bothdirections, and noise measurements.

TA24 Variable Indicates that the system used ATMEto perform a full signaling test. Thesystem used ATME to perform a busyflash-signaling test, a transmissiontest of noise measurements, and aloss frequency deviation.

TA25 Variable Indicates that the system used ATMEto perform a short signaling test and abusy flash-signaling test.

TCON Variable Indicates that the system performed aCommon Channel Inter-officeSignaling No. 6 (CCIS #6) continuitytest.

TCOT Variable Indicates that the system performed aCCIS #6 continuity test new versionon DTC.

TE_M Variable Indicates that the system performedan E and M lead signaling test.

TLPA Variable Indicates that the system performed aloop around test line-test. Indicatesthat the reference trunk occupies port1 of the transmission test trunk (TTT).

GROUP SYSTEMABORT: FIVECONSECUTIVEFAILURES

Variable Indicates that the system found fiveconsecutive failures during the searchfor a group reference trunk.

ACTION: Diagnose trunk testequipment.

HARDWAREFAILURE

Variable Indicates that the system encountereda hardware defect in the trunk circuit.

ACTION: Diagnose trunk under test.The trunk could have a hardwaredefect.

HIGH - DRY Variable Indicates that a far-end office did notsend an off-hook signal after a burst ofaudible ringing tone.

ACTION: Diagnose trunk under test. Ifdiagnostics pass, defect is in the far-end or transmission facility.

420 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 421: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

HIGH TONE Variable Indicates that the far-end officereturned a high frequency tone.

ACTION: Try test again.

HIT RECEIVED Variable Indicates that the system detected atransient condition in the trunk.

ACTION: Try test again.

INVALID REPLY Variable Indicates that the far-end officereturned an invalid signal when theDMS switch tried to outpulse digits.

ACTION: Diagnose trunk under test. Ifthe tests pass, the defect is in the far-end or in the transmission facility.

LOOP SIG FAULT Variable Indicates a defect in the loop bridge,or the receiving equipment caused asignaling failure.

ACTION: Diagnose test equipment.

LOOP SIG FAULTNOSET

Variable Indicates a defective software or loopgenerating equipment caused asignaling failure.

ACTION: Check trunk and testparameters and options. Diagnosetest equipment.

LTA CANCELLED Variable Indicates that the local trunk alarm(LTA) was improperly canceled

ACTION: Diagnose test equipment,and try test again.

LTU FAULT Variable Indicates that the system detected adefect in line test unit (LTU).

ACTION: Diagnose LTU.

MILLIWATT Variable Indicates that the far-end officereturned a milliwatt tone.

ACTION: Try test again.

ATT102 421

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 422: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

NO/BAD CSCRESPONSE

Variable Indicates that the system attempted toperform a cellular trunk test. Indicatesthe system did not receive a responseor received a response that was notexpected.

ACTION: Diagnose CSC.

NO/BAD RCURESPONSE

Variable Indicates that the system attempted acellular trunk test. The cellular remotecarrier urban (RCU) received aresponse that was not planned or noresponse.

ACTION: Diagnose RCU.

NO/BAD TAURESPONSE

Variable Indicates an attempt made to performa cellular trunk test. The cellular testand alarm unit (TAU) received aresponse that was not planned or noresponse.

ACTION: Diagnose TAU.

NO CARD IN SHELF Variable Indicates that the circuit pack ismissing.

ACTION: Check the installation of thetrunk circuit equipment.

NO FAR END TESTEQUIPMENT

Variable Indicates that the far-end testequipment does not exist or is notavailable.

ACTION: Diagnose trunk under test. Iftests pass, the defect is in the far-endoffice or in the transmission facility.

NO LOGICAL MB Variable Indicates that the software bug did notprevent the allocation of the logicalmessage buffer (MB).

ACTION: Try test again.

NO START DIALSIGNAL

Variable Indicates that the far-end office did notrespond after the system seized thetrunk.

ACTION: Try test again.

422 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 423: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

NO TESTEQUIPMENT

Variable Indicates that the test equipment wasnot available.

ACTION: Check the trunk and testparameters and options.

NO TESTLINENUMBER

Variable Indicates that the software bugprevented the trunk circuit from beingfound.

ACTION: Check the trunk and testparameters and options. Retry test.

NO TONE Variable Indicates that the far-end office failedto return the correct tone.

ACTION: Try test again.

NO TRUNKS INGROUP

Variable Indicates that a software bug does notallow the system to find the trunks inthe group.

ACTION: Check trunk and testparameters and options. Try testagain.

NOT OG OR 2WTRUNK GROUP

Variable Indicates that a test attemptedtransmission or attempted loss testson a trunk that was not an outgoing ortwo-wire trunk.

ACTION: Check trunk and testparameters and options.

OUTPULSINGTROUBLE

Variable Indicates trouble encountered whenthe system transmitted digits.

ACTION: Diagnose trunk under test. Iftests pass, defect is in the far-endoffice or transmission facility.

OVERFLOW TONE Variable Indicates that the far-end officereturned an overflow tone.

ACTION: Try test again.

PARAMETER FAULT Variable Indicates that the parameters arewrong or not compatible for test type.

ACTION: Check trunk and testparameters and options.

ATT102 423

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 424: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

PERIODIC SIGNAL Variable Indicates that the far-end officereturned a signal that was periodic ornot continuous.

ACTION: Try test again.

PM FAULT Variable Indicates a defect in the peripheralmodule (PM).

ACTION: Diagnose PM.

TLPB Variable Indicates that the system performed aloop around test line-test. Indicatesthat the reference trunk occupies porttwo of TTT.

TL0N Variable Indicates that the system performed aloss (1004 Hz at 0 dBm) and noise(C_message filter) test. Indicates thesystem used a 105-type test line.

TL0S Variable Indicates that the system used a 105-type test line to perform a loss (1004Hz at 0 dBm) test with a self-check.

TL05 Variable Indicates that the system used a 105-type test line to perform a loss (1004Hz at 0 dBm) test.

TEST EQUIPMENTFAULT

Variable Indicates that the system detected adefect in the test equipment.

ACTION: Diagnose trunk testequipment.

TEST EQUIPMENTUNAVAILABLE

Variable Indicates that the test equipment wasnot available for testing. The systemgenerates this report every 10 min ifthe test equipment does not becomeavailable.

ACTION: There is no required action.

TEST NOTALLOWED

Variable Indicates that the test is not allowedon circuit.

ACTION: Check trunk and testparameters and options.

TEST PROCESSTROUBLE

Variable Indicates that there were problemswith the test process.

424 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 425: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Try test again.

TEST PROTOCOLTROUBLE

Variable Indicates a software bug or aresponse from the far-end office thatwas not planned.

ACTION: Try test again.

TESTLINE NOTAVAILABLE

Variable Indicates that the test is not availablein the current load.

ACTION: Check trunk and testparameters and options.

TONE DETECTIONFAILED

Variable Indicates a failure to detect the correcttone.

ACTION: Diagnose trunk testequipment.

TPT TONE Variable Indicates that the far-end officereturned a test progress tone (TPT).Indicates this result was not expected.

ACTION: Try test again.

TRUNK GROUPTIMEOUT

Variable Indicates the waiting time for eachtrunk in the trunk group to becomeavailable for testing. The allowedwaiting time is in the customer dataTable ATTSCHED.

ACTION: Check WAIT_TIME incustomer data Table ATTSCHED. Trytest again.

TRUNK NOTTESTED CFL

Variable Indicates trunk circuit was not testedbecause it was carrier failed.

ACTION: Contact the next level ofmaintenance.

TRUNK NOTTESTED CPD

Variable Indicates that the trunk circuit was nottested because the circuit was callprocessing deloaded.

ACTION: When the trunk state returnsto IDLE, try test again.

TRUNK NOTTESTED CPB

Variable Indicates that the trunk circuit was nottested because the circuit was callprocessing busy.

ATT102 425

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 426: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: When the trunk state returnsto IDLE, try test again.

TRUNK NOTTESTED DEL

Variable Indicates that the trunk circuit was nottested because the circuit is deloaded.

ACTION: Return trunk to service. Trytest again.

TRUNK NOTTESTED IDL

Variable Indicates that the trunk circuit was nottested because the circuit was idle.

ACTION: Return trunk to service. Trytest again.

TRUNK NOTTESTED IMB

Variable Indicates that the trunk circuit was nottested because the circuit was offline.

ACTION: Return the trunk to service.Try test again.

TRUNK NOTTESTED INI

Variable Indicates that the trunk circuit was nottested because the circuit initialized.

ACTION: Return the trunk to service.Try test again.

TRUNK NOTTESTED LO

Variable Indicates the trunk circuit was nottested because the circuit was lockedout.

ACTION: Contact the next level ofmaintenance.

TRUNK NOTTESTED MB

Variable Indicates that the trunk circuit was nottested because the circuit wasmanually busy.

ACTION: Return the trunk to service.Try test again.

TRUNK NOTTESTED NEQ

Variable Indicates that the trunk circuit was nottested because the circuit was notequipped.

ACTION: Return the trunk to service.Try test again.

TRUNK NOTTESTED NMB

Variable Indicates that the system did not testthe trunk circuit because the circuitwas network management busy.

426 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 427: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: When the trunk returns tothe IDLE state, try test again.

TRUNK NOTTESTED PMB

Variable Indicates that the system did not testthe trunk circuit because the circuitwas PM busy

ACTION: Contact the next level ofmaintenance.

TRUNK NOTTESTED RES

Variable Indicates that the system did not testthe trunk circuit because the circuitwas in restricted idle.

ACTION: When trunk state returns tothe IDLE state, try test again.

TL6N Variable Indicates that the system used a 105-type test line to perform a loss (404,1004, and 2804 Hz at -16 dBm) andnoise (C_notched filter) test.

TL6S Variable Indicates that the system used a 105-type test line to perform a loss (404,1004, and 2804 Hz at -16 dBm) testwith self-check.

TL65 Variable Indicates that the system used a 105-type test line to perform a loss (404,1004, and 2804 Hz at-16 dBm) test.

TNSS Variable Indicates that the system performed anon-synchronous test line test.

TR2L Variable Indicates that the system performed arepeat 2 long-delay test.

TR2S Variable Indicates that the system performed arepeat 2 short-delay test.

TSBS Variable Indicates that the system performed afar-end equipment self-check of loss(404, 1004, and 2804 Hz test tone at-16 dB), a noise (C_notched filter) areturn loss test. Indicates the systemused a 105-type test line.

TSBT Variable Indicates that the system performed areturn loss measurement test.

TSYN Variable Indicates that the system performed asynchronous test-line test.

ATT102 427

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 428: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TS65 Variable Indicates that the system performed afar-end equipment self-check of loss(404, 1004, and 2804 Hz test tone at-16 dB), and a noise (C_notchedfilter). Indicates the system used a105-type test line.

T100 Variable Indicates that the system used a 100-type test line to perform a milliwatt andbalance test. The version (old or new)is not known.

RECORDEDANNOUNCEMENT

Variable Indicates that the far-end officereturned a recorded announcement.

ACTION: Try test again.

REORDER TONE Variable Indicates that the far-end officereturned a reorder tone.

ACTION: Try test again.

RINGING Variable Indicates that the far-end office did notrespond to ringing.

ACTION: Diagnose trunk under test. Iftests pass, the defect is in the far-endor transmission facility.

STOP DIAL SIGNALRECEIVED

Variable Indicates that the far-end officereturned a congestion signal duringtransmission of digits.

ACTION: Try test again.

TAU NOTAVAILABLE

Variable Indicates that the system attempted acellular trunk test, but the TAU was inuse or not available.

ACTION: Try test again.

TEST EQUIPMENTFAIL

Variable Indicates the detection of a defect inthe test equipment.

ACTION: Diagnose trunk testequipment.

Active message exampleATT102 APR01 12:00:00 2112 INFO

CKT CAMA2W 1

428 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 429: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FP503 SEP05 18:14:33 4827 INFO Device State Change

Location: FP 2 DEVICE 1 (DK) SCSI BUS 0

REASON: Change of state of associated entity

FROM: InSv ( Isolated )

DRIVE STATE: Unknown

TO: InSv

DRIVE STATE: On LineT102

CONNECTION FAILURE

FAIL

Clear message examplen/a

Associated OM registers

ATT103The Automatic Trunk Testing (ATT) subsystem generates ATT103 whenthe subsystem encounters trunk test protocol problems and aborts the test.

Remedial actionIf you find reastxt in the preceding table, use the following references.These references will help you to isolate and correct failures that ATT101indicated.

For entry failures, refer to the data schema section of the TranslationsGuide. For failures associated with trunk equipment, refer to CardReplacement Procedures. This reference provides step-by-stepprocedures to isolate and correct trunk and test equipment failures. Formore information concerning trunk testing, refer to the Trunks MaintenanceGuide.

If you cannot find reastxt in the preceding table, contact the next level ofmaintenance.

ATT103 429

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 430: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

Format1.ATT103 mmmdd hh:mm:ss ssdd INFO

CKT trkid

tstnm TESTLINE PROTOCOL FAILED reastxt

PROTOCOL

Selected field descriptionsField Value Fixed or

VariableDescription

TAU NOTAVAILABLE

Variable Indicates that the system attempted acellular trunk test and the test andalarm unit were in use or notavailable.

ACTION: Try test again.

TEST EQUIPMENTFAIL

Variable Indicates that the system detectedfaults in the test equipment.

ACTION: Find the defects in the trunktest equipment.

TEST EQUIPMENTFAULT

Variable Indicates that the system detectedfaults in the test equipment.

ACTION: Find the defects in the trunktest equipment.

TEST EQUIPMENTUNAVAILABLE

Variable Indicates that the test equipment wasnot available for the test. The systemgenerates this report every 10 min iftest equipment remains not available.

ACTION: There is no required action.

TEST NOTALLOWED

Variable Indicates that the test is not allowedon circuit.

ACTION: Check trunk and testparameters and options.

TEST PROCESSTROUBLE

Variable Indicates that problems with the testprocess.

430 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 431: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Try the test again.

TEST PROTOCOLTROUBLE

Variable Indicates a software bug or aresponse that was not planned fromfar-end office.

ACTION: Try test again.

TESTLINE NOTAVAILABLE

Variable Indicates that the test is not availablein the current load.

ACTION: Check trunk and testparameters and options.

TONE DETECTIONFAILED

Variable Indicates a failure to detect correcttone.

ACTION: Find the defects in the trunktest equipment.

TPT TONE Variable Indicates that the far-end officereturned a test progress tone (TPT)that was not expected.

ACTION: Try test again.

TRUNK GROUPTIMEOUT

Variable Indicates the time expired waiting foreach trunk in the trunk group to beavailable for testing. The allowedwaiting time is set in customer dataTable ATTSCHED.

ACTION: Check WAIT_TIME incustomer data Table ATTSCHED. Trytest again.

TRUNK NOTTESTED CFL

Variable Indicates that the system did not testthe trunk circuit because it was carrierfailed.

ACTION: Contact the next level ofmaintenance.

TRUNK NOTTESTED CPD

Variable Indicates that the system did not testthe trunk circuit because it was callprocessing deloaded.

ACTION: When the trunk state returnsto IDLE, try test again.

ATT103 431

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 432: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TRUNK NOTTESTED CPB

Variable Indicates that the system did not testthe trunk circuit because it was callprocessing busy.

ACTION: When trunk state returned toIDLE, try test again.

TRUNK NOTTESTED DEL

Variable Indicates that the system did not testthe trunk circuit. It is deloaded.

ACTION: Return trunk to service. Trytest again.

TRUNK NOTTESTED IMB

Variable Indicates that the system did not testthe trunk circuit. It was offline.

ACTION: Return trunk to service. Trytest again.

TRUNK NOTTESTED INI

Variable Indicates that the system did not testthe trunk circuit. It was initialized.

ACTION: Return trunk to service. Trytest again.

TRUNK NOTTESTED LO

Variable Indicates that the system did not testthe trunk circuit. The circuit waslocked out.

ACTION: Contact the next level ofmaintenance.

TRUNK NOTTESTED MB

Variable Indicates that the system did not testthe trunk circuit. It was manually busy.

ACTION: Return trunk to service. Trytest again.

TRUNK NOTTESTED NEQ

Variable Indicates that the system did not testthe trunk circuit. The circuit wasunequipped.

ACTION: Return trunk to service. Trytest again.

TRUNK NOTTESTED NMB

Variable Indicates that the system did not testthe trunk circuit was because it wasnetwork management busy.

ACTION: When trunk state returns toIDLE, try test again.

432 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 433: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TRUNK NOTTESTED PMB

Variable Indicates that the system did not testthe trunk circuit. It was PM busy.

ACTION: Contact the next level ofmaintenance.

TRUNK NOTTESTED RES

Variable Indicates that the system did not testthe trunk circuit. It was in restrictedidle.

ACTION: When the trunk state returnsto IDLE, try test again.

TRUNK NOTTESTED RMB

Variable Indicates that the system did not testthe trunk circuit because it was remotebusy.

ACTION: Contact the next level ofmaintenance.

TRUNK NOTTESTED SB

Variable Indicates that the system did not testthe trunk circuit because it wassystem busy.

ACTION: Contact the next level ofmaintenance.

TRUNK NOTTESTED SZD

Variable Indicates that the system did not testthe trunk circuit because it wasalready seized. ACTION: When trunkstate returns to IDLE, try test again.

TRUNK TIMEOUT Variable Indicates time expired while thesystem waited for each trunk to beavailable for testing. The allowedwaiting time is set in customer dataTable ATTSCHED.

ACTION: Check WAIT_TIME incustomer data Table ATTSCHED. Trytest again.

TST EQUIPMNT NOTREQUIRED

Variable Indicates difference in the requestedtest. The requested test called forequipment which was not necessary.

ACTION: Check trunk and testparameters and options.

TTU FAULT Variable Indicates defect found in thetransmission test unit (TTU).

ATT103 433

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 434: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Find the defects in the TTU.

UNEXPECTED TONE Variable Indicates that the far-end officereturned a tone that was not plannedor not known.

ACTION: Find the faults in the trunktest equipment.

UNKNOWN ATTMESSAGE

Variable Indicates a software bug. Thismessage always occurs before asoftware error (SWER) report.

ACTION: Contact the next level ofmaintenance.

WRONG CARD INSHELF

Variable Indicates a wrong circuit pack installedin the shelf.

ACTION: Check trunk circuitequipment installation.

120 IPM TONE Variable Indicates that the far-end officereturned a signal at 120 impulses foreach minute.

ACTION: Try test again.

30 IPM TONE Variable Indicates that the far-end officereturned a signal at 30 impulses foreach minute.

ACTION: Try test again.

PROTOCOL Constant Fixed Indicates that protocol failure occurredduring an ATT trunk test.

TA12 Variable Indicates that the system used ATMEto perform a short signaling test.

TA13 Variable Indicates that the system used ATMEto perform a busy flash-signaling test.

TA14 Variable Indicates that the system used ATMEto perform a busy flash-signaling testand a transmission test of levelmeasurements in both directions.

TA15 Variable Indicates that the system used ATMEto perform a busy-flash signaling testand a transmission test of lossfrequency deviation.

434 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 435: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TA16 Variable Indicates that the system used ATMEto perform a busy flash-signaling testand a transmission test of noisemeasurements.

TA17 Variable Indicates that the system used ATMEto perform a busy-flash signaling test,a transmission test of levelmeasurements in both directions, andnoise measurements.

TA18 Variable Indicates that the system used ATMEto perform a busy-flash signaling test,a transmission test of loss frequencydeviation, and noise measurements.

TA19 Variable Indicates that the system used ATMEto perform a full signaling test and abusy-flash signaling test.

TA20 Variable Indicates that the system used ATMEto perform a full signaling test, a busy-flash signaling test, and atransmission test of levelmeasurements in both directions.

TA21 Variable Indicates that the system used ATMEto perform a full signaling test, a busy-flash signaling test, and atransmission test of loss frequencydeviation.

TA22 Variable Indicates that the system used ATMEto perform a full signaling test, a busy-flash signaling test, and transmissiontest of noise measurements.

TA23 Variable Indicates that the system used ATMEto perform a full signaling test, a busy-flash signaling test, a transmissiontest of level measurements in bothdirections, and noise measurements.

TA24 Variable Indicates that the system used ATMEto perform a full signaling test, a busy-flash signaling test, and transmissiontest of noise measurements and lossfrequency deviation.

TA25 Variable Indicates that the system used ATMEto perform a short signaling test and abusy-flash signaling test.

ATT103 435

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 436: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TCON Variable Indicates that the system performed aCommon-Channel InterofficeSignaling No. 6 (CCIS6) continuitytest.

TCOT Variable Indicates that the system performed aCCIS6 continuity test on digital trunkcontroller (DTC).

TE_M Variable Indicates that the system performedan E and M lead signaling test.

TLPA Variable Indicates that the system performed aloop-around test line test. Thereference trunk occupies port 1 of thetransmission test trunk (TTT).

TLPB Variable Indicates that the system performedthe loop-around test line test. Thereference trunk occupies port 2 of theTTT.

TL0N Variable Indicates that the system used a 105-type test line to perform a loss (1004Hz at zero dBm) and noise (C-message filter) test.

TL0S Variable Indicates that the system used a 105-type test line to perform a loss (1004Hz at zero dBm) test with a self-check.

TL05 Variable Indicates that the system used a 105-type test line to perform a loss (1004Hz at zero dBm) test.

TL6N Variable Indicates that the system used a 105-type test line to perform a loss (404,1004, and 2804 Hz at -16 dBm) andnoise (C-notched filter) test.

TL6S Variable Indicates that the system used a 105-type test line to perform a loss (404,1004, and 2804 Hz at -16 dBm) testwith self-check.

TL65 Variable Indicates that the system used a 105-type test line to perform a loss (404,1004, and 2804 Hz at-16 dBm) test.

TNSS Variable Indicates that the system performed anonsynchronous test line test.

TR2L Variable Indicates that the system performed arepeat 2 long delay test.

436 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 437: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TR2S Variable Indicates that the system performed arepeat 2 short delay test.

TSBS Variable Indicates that the system performed afar-end equipment self-check of loss(404, 1004, and 2804 Hz test tone at-16 dB), noise (C-notched filter), andreturn loss test. Indicates the systemused a 105-type test line.

TSBT Variable Indicates that the system performed areturn loss measurement test.

TSYN Variable Indicates that the system performed asynchronous test line test.

TS65 Variable Indicates that the system performed afar-end equipment self-check of loss(404, 1004, and 2804 Hz test toneat-16 dB) and noise (C-notched filter).Indicates the system used a 105-typetest line.

T100 Variable Indicates that the system used a 100-type test line to perform a milliwatt andbalance test. Indicates the version (oldor new) is not known.

T102 Variable Indicates that the system used a 102-type test line a milliwatt test.

T103 Variable Indicates that the system used a 103-type test line a signaling test.

T104 Variable Indicates that the system used a 104-type test line a milliwatt test in bothdirections.

T105 Variable Indicates that the system performed aloss (1004 Hz at zero dBm) and noise(C-message filter) test with self-check.Indicates the system used a 105-typetest line.

T165 Variable Indicates that the system performed aloss (404, 1004, and 2804 Hz at -16dBm) and noise (C-notched filter) testwith self-check. Indicates the systemused a 105-type test line.

ATT103 437

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 438: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

T5AS Variable Indicates that the system performed aloss (1004 Hz at zero dBm), noise (C-message filter), and return loss testwith self-check. Indicates the systemused a 105-type test line.

T5AT Variable Indicates that the system performed aloss (C1004 Hz at zero dBm), noise(C-message filter), and return loss(C1004 Hz at zero dBm) test.Indicates the system used a 105-typetest line.

INFO Constant Fixed Indicates data that follows provides areport when trunk test protocol troubleoccurs and the system aborts the test.

CKT Symbolic text Variable Provides equipment identificationsuspect trunk equipment.

tstnm DIAG Variable Indicates that the system performedan extended diagnostic test.

MXAM Variable Indicates that the system performed amobile telephone exchange (MTX)audio loop test with a C-messagefilter.

MXAN Variable Indicates MTX audio loop test with aC-notch filter was performed.

MXRM Variable

MXRN Variable Indicates that the system performedan MTX radio frequency loop test witha C-notch filter.

MXWM Variable Indicates that the system performedan MTX wire loop test with a C-message filter.

MXWN Variable Indicates that the system performedan MTX wire loop test with a C-notchfilter.

N100 Variable Indicates that the system used a 100-type test line to perform a new versionof the milliwatt and balance test.

S100 Variable Indicates that the system used a 100-type test line to perform only an oldversion of balance test.

TART Variable Indicates that the system performed aTurkey arter test line test.

438 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 439: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TA01 Variable Indicates that the system performed atransmission test of levelmeasurements in both directions.Indicates the system used anautomatic transmission measuringequipment (ATME).

TA02 Variable Indicates that the system used ATMEto perform a transmission test of lossfrequency deviation.

TA03 Variable Indicates that the system used ATMEto perform a transmission test of noisemeasurements.

TA04 Variable Indicates that the system used ATMEto perform a transmission test of levelmeasurements in both directions andnoise measurements.

TA05 Variable Indicates that the system used ATMEto perform a transmission test of lossfrequency deviation and noisemeasurements.

TA06 Variable Indicates that the system used ATMEto perform a full signaling test.

TA07 Variable Indicates that the system used ATMEto perform a full signaling test andtransmission test of levelmeasurements in both directions.

TA08 Variable Indicates that the system used ATMEto perform a full signaling test andtransmission test of loss frequencydeviation.

TA09 Variable Indicates that the system used ATMEto perform a full signaling test andtransmission test of noisemeasurement.

TA10 Variable Indicates that the system used ATMEto perform a full signaling test, atransmission test of levelmeasurements in both directions, andnoise measurements.

TA11 Variable Indicates that the system used ATMEto perform a full signaling test, atransmission test of loss frequencydeviation, and noise measurements.

ATT103 439

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 440: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

T5BS Variable Indicates that the system performed areturn loss measurement and self-check test. Indicates the system useda 105-type test line.

T5LB Variable Indicates that the system used a 105-type test line to perform a loss (404,1004, and 2804 Hz at -16 dBm) andreturn loss test. Indicates the system.

T5SB Variable Indicates that the system used a 105-type test line to perform a return losstest with self-check was performed.

T50L Variable Indicates that the system used a 105-type test line to perform a loss (1004Hz at zero dBm) and return loss(C1004 Hz at zero dBm) test.

T56N Variable Indicates that the system used a 105-type test line to perform a loss (404,1004, and 2804 Hz at -16 dBm), noise(C-notched filter), and return loss test.

TESTLINEPROTOCOL FAILED

Constant Fixed Indicates that a protocol failureoccurred when the system executedan ATT trunk test.

reastxt ACTIVE TABLE FULL Variable Indicates that more trunk tests werecalled to execute than the presentsetting in customer data TableATTSCHED permits.

ACTION: Change the number ofsimultaneous tests from the ATT MAPlevel.

BUSY TONE Variable Indicates that the far-end officereturned a busy tone.

ACTION: Try test again.

CARD FAULT Variable Indicates that the system encountereda hardware defect in the circuit pack.

ACTION: Replace the circuit pack.

CONNECTIONFAILURE

Variable Indicates a connection failure betweenthe trunk and the test equipment.

ACTION: Find the defects in the trunktest equipment.

440 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 441: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

COULDN'T OPENATTOPTNS

Variable Indicates that a software bugprevented the opening or access tocustomer data Table ATTOPTNS.

ACTION: Try test again.

COULDN'T READATTOPTNS

Variable Indicates that the required entry incustomer data Table ATTOPTNS isnot present for the specified test class.

ACTION: Check trunk and testparameters and options. Try testagain.

CSC MTCE INPROGRESS

Variable Indicates that an attempt to perform acellular trunk test occurred whilemaintenance of the cell site controller(CSC) was in progress.

ACTION: Try test again.

DATA FAULT Variable Indicates that there were problemswith the received test result data.

ACTION: Try test again.

DIAGNOSTIC NOTALLOWED

Variable Indicates that the test was initiated ona circuit not equipped for that testtype.

ACTION: Check the trunk and testparameters and options.

DIAL TONE Variable Indicates that a far-end office returneda dial tone.

ACTION: Try test again.

FACILITY FAULT Variable Indicates a defect in the transmissionfacilities.

ACTION: Find the defects in the trunkand test equipment.

FAILED TO RUNDIAGNOSTIC

Variable Indicates that the test equipment wasnot available or inoperative.

ACTION: Find the defects in the trunkand test equipment.

ATT103 441

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 442: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

FAILED TO RUNTESTLINE

Variable Indicates that a software bug duringinitial setup prevented the test.Normally indicates that processes arenot available.

ACTION: Try test again.

GROUPCURRENTLYUNDER TEST

Variable Indicates that the trunk groupexecuted a trunk testand the systemignored the second test request.

ACTION: There is no required action.

GROUP MANUALABORT

Variable Indicates that the test was manuallyaborted from the ATT MAP levelbecause the user:

• stopped the group test.

• reduced the number ofsimultaneous tests ATT canexecute.

• stopped all ATT tests (HaltATT).

ACTION: There is no required action.

GROUP SYSTEMABORT:REFERENCE TRUNKFAILURE

Variable Indicates that the five consecutivefailures occurred and the systemtested the reference trunk again. Thereference trunk failed the next test andthe system aborted the group.

ACTION: Find the defects in the trunktesting equipment and referencetrunks.

GROUP SYSTEMABORT:REFERENCE TRUNKUNAVAILABLE

Variable Indicates that five consecutive failuresoccurred and the system tested thereference trunk again. The system didnot seize the reference trunk and thesystem aborted the group test.

ACTION: Find the defects in the trunktesting equipment and referencetrunks.

GROUP SYSTEMABORT: 5CONSECUTIVEFAILURES

Variable Indicates that five consecutive failuresoccurred during a search for a groupreference trunk.

442 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 443: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Find the defects in the trunktest equipment.

HARDWAREFAILURE

Variable Indicates that the system detectedhardware defects in the trunk circuit.

ACTION: Find the defects in the trunkunder test. The trunk can havehardware defects.

HIGH - DRY Variable Indicates that after a burst of audibleringing tone, the far-end office did notsend an off-hook signal.

ACTION: Find the faults in the trunkunder test. If diagnostics pass,damage is in the far-end ortransmission facility.

HIGH TONE Variable Indicates that the far-end officereturned a high frequency tone.

ACTION: Try test again.

HIT RECEIVED Variable Indicates that the system detected atemporary condition in the trunk.

ACTION: Try test again.

INVALID REPLY Variable Indicates that the far-end officereturned a signal that is not correctwhen the DMS switch tried to transmitdigits.

ACTION: Find the defects in the trunkunder test. If tests pass, the defect isin the far-end or transmission facility.

LOOP SIG FAULT Variable Indicates that a defect in the loopbridge or the receiving equipmentcaused a signaling failure.

ACTION: Find the defects in the testequipment.

LOOP SIG FAULTNOSET

Variable Indicates that defect in the software orloop generating equipment caused asignaling failure.

ATT103 443

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 444: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Check trunk and testparameters and options. Find thedefects in the test equipment.

LTA CANCELLED Variable Indicates that the local trunk alarm(LTA) was not cancelled correctly.

ACTION: Find the defects in the testequipment, and try the test again.

LTD FAULT Variable Indicates that the system detected afault in the line test unit (LTU).

ACTION: Find the defects in the LTU.

MILLIWATT Variable Indicates that the far-end officereturned a milliwatt tone.

ACTION: Try test again.

NO/BAD CSCRESPONSE

Variable Indicates that a cellular trunk testattempt caused no response or aresponse that was not planned fromthe CSC.

ACTION: Find the defects in the CSC.

NO/BAD RCURESPONSE

Variable Indicates that a cellular trunk testattempt caused a response that wasnot planned or no response from thecellular remote carrier urban (RCU).

ACTION: Find the defects in the RCU.

NO/BAD TAURESPONSE

Variable Indicates that a cellular trunk testattempt caused no response or aresponse that was not planned fromthe cellular test and alarm unit (TAU).

ACTION: Find the defects in the TAU.

NO CARD IN SHELF Variable Indicates that the circuit pack is notpresent.

ACTION: Check the trunk circuitequipment installation.

NO FAR END TESTEQUIPMENT

Variable Indicates that the far-end testequipment was not available or doesnot exist.

444 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 445: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Find the faults in the trunkunder test. If the tests pass, the faultis in the far-end or transmissionfacility.

NO LOGICAL MB Variable Indicates that a software bugprevented the allocation of no logicalmessage buffer (MB).

ACTION: Try the test again.

NO START DIALSIGNAL

Variable Indicates that the far-end office did notrespond after the trunk was seized.

ACTION: Try the test again.

NO TESTEQUIPMENT

Variable Indicates that the test equipment isnot available.

ACTION: Check trunk and testparameters and options.

NO TESTLINENUMBER

Variable Indicates that the software bugprevented the detection of the trunkcircuit.

ACTION: Check trunk and testparameters and options. Try the testagain.

NO TONE Variable Indicates that the far-end office doesnot return the correct tone.

ACTION: Try test again.

NOT OG OR 2WTRUNK GROUP

Variable Indicates that the test attemptedtransmission or loss tests on a trunkthat was not an outgoing or 2-wiretrunk.

ACTION: Check trunk and testparameters and options.

OUTPULSINGTROUBLE

Variable Indicates that problems occurred whilethe system transmitted outpulsingdigits.

ACTION: Find the faults in the trunkunder test. If tests pass, damage is inthe far-end or transmission facility.

ATT103 445

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 446: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

OVERFLOW TONE Variable Indicates that the far-end officereturned an overflow tone.

ACTION: Try test again.

PARAMETER FAULT Variable Indicates that the parameters werewrong or not compatible for the testtype.

ACTION: Check the trunk and testparameters and options.

PERIODIC SIGNAL Variable Indicates that the far-end officereturned a periodic signal or a signalthat is not continuous.

ACTION: Try test again.

NO TRUNKS INGROUP

Variable Indicates that a software bugprevented the detection of trunks inthe group.

ACTION: Check trunk and testparameters and options. Try testagain.

PM FAULT Variable Indicates that ta defect occurred in theperipheral module (PM).

ACTION: Find the defects in the PM.

RECORDEDANNOUNCEMEN T

Variable Indicates that the far-end officereturned a recorded announcement.

ACTION: Try test again.

REORDER TONE Variable Indicates that the far-end officereturned a reorder tone.

ACTION: Try the test again.

RINGING Variable Indicates that the far-end officeignored the ringing.

ACTION: Find fault in the the trunkunder test. If tests pass, the defect isin the far-end or transmission facility.

STOP DIAL SIGNALRECEIVED

Variable Indicates that a far-end office returneda congestion signal when the systemtransmits digits.

446 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 447: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Try test again.

Active message example1.ATT103 APR01 12:00:00 2112 INFO

CKT CAMA2W 1

T102 TESTLINE PROTOCOL FAILED HIGH AND DRY PROTOCOL

Clear message examplen/a

Associated OM registers

ATT104The Automatic Trunk Testing (ATT) subsystem report ATT104. Thesubsystem generates this report when a N100/T100 trunk test is complete.The N100 is the new version of the 100-type test line and measures far-to-near end noise and loss. The T100 is the default test when the version isnot known.

To select the correct test, the DMS switch waits 2 s after the far-end officegoes off-hook. If a milliwatt tone appears during this time, the systemperforms the N100 test. If a milliwatt tone does not appear, the systemperforms the T100 test.

The DMS and the far-end office install and execute N100 as follows:

• The DMS connects a transmission test trunk (TTT) level meter to theoutgoing trunk.

• The DMS transmits a test code to the far-end office.

• The far-end office responds with an off-hook signal when a milliwattgenerator connects to the test trunk.

• The far-end office applies a milliwatt tone to the test trunk.

• The DMS measures the signal loss.

• The far-end office provides quiet termination to the trunk.

• The DMS measures the noise.

• The test terminates and the trunk becomes free.

There is no additional information

ATT104 447

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 448: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionIf rslttxt = PASS, there is no action required.

If rslttxt = FAIL, refer to Card Replacement Procedures for step-by-stepprocedures. Take immediate action if qltxt = Q2.

AttributesAttribute Value

Severity Warning

Format1.ATT104 mmmdd hh:mm:ss ssdd INFO

CKT trkid

tstnm EML: nn.n FN_DEV: nn.n rslttxt

NML: nn NIAL: nn NOISE: nn.n qltxt

Selected field descriptionsField Value Fixed or

VariableDescription

INFO Constant Fixed Indicates that the following datagenerate this report when N100/T100trunk test is complete

CKT Symbolic text Variable Provides equipment identification forsuspect trunk equipment.

tstnm N100 Variable Indicates the system used 100-typetest line to perform new version ofmilliwatt and balance test

T100 Variable Indicates the system used 100-typetest line to perform milliwatt andbalance test. The system did not knowthe version (old or new) in advance

EML 0.0 to 36.0 Variable Provides expected measured loss(EML) in decibels. The EML valueappears in user data TableCLLIMTCE.DIAGDATA.

FN_DEV -99.9 to +99.9 dB Variable Provides far-to-near end lossdeviation in decibels. The fieldFN_DEV indicates the differencebetween measured loss on trunk andEML in decibels.

448 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 449: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

*** Variable Indicates far-to-near end deviation ismore than 99.9 dB

rslttxt PASS Variable Indicates test passed. Noise and lossmeasurements are betweenacceptable limits.

FAIL Variable Indicates test failed. Noise and lossmeasurements were not betweenacceptable limits.

NML 1 to 63 Variable Provides noise maintenance limit(NML) in decibels above referencenoise. The NML is an entered value incustomer data TableCLLIMTCE.DIAGDATA. If the noisemeasurement exceeds NML, initiatemaintenance action.

NOISE -99.9 to +99.9 Variable Provides accurate far-to-near endnoise measured on trunk in decibelsabove reference noise

qltxt Blank Variable Indicates transmission measurementswere between acceptable limits.

Q1 Variable Indicates transmission measurementswere within maintenance limit. Initiatemaintenance action.

Q2 Variable Indicates transmission measurementsexceeded immediate action limit.Initiate immediate action.

Active message example1.ATT104 APR01 12:00:00 2112 INFO

CKT CAMA2W 1

T100 EML: 6.0 FN_DEV: 2.2

PASS

NML: 10 NIAL: 20 NOISE: 12 Q1

Clear message examplen/a

ATT104 449

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 450: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ATT105The Automatic Trunk Testing (ATT) subsystem generates this report whena S100/T100 trunk test is complete. An S100 is the new version of the 100-type test line, and the S100 measures far-to-near end noise. The T100 testis the default test for when the system does not know the version.

To select the correct test, the DMS waits two seconds after the far-endoffice goes off-hook. If a milliwatt tone appears during this time, the systemperforms the new S100 test. The system performs the default test T100when the system does not know the version.

The DMS and the far-end office install and execute S100 as follows:

• The DMS connects a transmission test trunk (TTT) level meter to theoutgoing trunk.

• The DMS sends a test code to the far-end office.

• The far-end office responds with an off-hook signal, and provides quiettermination to the trunk.

• The DMS measures the noise.

• The test terminates and the trunk becomes free.

There is no additional information

Remedial actionIf rslttxt = PASS, there is no required action.

If rslttxt = FAIL, refer to Card Replacement Procedures , for step-by-stepprocedures. If qltxt = Q2, the user must take immediate action.

AttributesAttribute Value

Severity Warning

Format1.ATT105 mmmdd hh:mm:ss ssdd INFO

CKT trkid

tstnm NML: nn NIAL: nn NOISE: nn.n qltxt rslttxt

450 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 451: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFO Constant Fixed Indicates that the following datagenerate this report when an S100/T100 trunk test is complete

CKT Symbolic text Variable Provides equipment identification forsuspect trunk equipment.

tstnm S100 Variable Indicates that the system used the100-type test line to perform the oldversion of the balance test.

T100 Variable Indicates that the system used the100_type test line to perform themilliwatt and balance test. The systemdid not know the version in advance.

NML 1 to 63 Variable Provides noise maintenance limit(NML) in decibels above referencenoise. The NML value appears in userdata Table CLLIMTCE.DIAGDATA. Ifthe noise measurement exceedsNML, the user must beginmaintenance action.

NIAL 1 to 63 Variable Provides noise immediate action limit(NIAL) in decibels above referencenoise. The value NIAL appears in userdata Table CLLIMTCE.DIAGDATA. Ifthe noise measurement exceedsNIAL, the user must begin immediatemaintenance action.

NOISE -99.9 to +99.9 Variable Provides accurate far-to-near endnoise measurement on trunk indecibels above reference noise.

qltxt Blank Variable Indicates transmission measurementswere between acceptable limits.

Q1 Variable Indicates transmission measurementswere between maintenance limits. Theuser must begin maintenance action.

Q2 Variable Indicates transmission measurementsexceeded immediate action limit. Theuser must begin immediatemaintenance action.

ATT105 451

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 452: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

rslttxt PASS Variable Indicates test passed. Noisemeasurements were betweenacceptable limits.

FAIL Variable Indicates test failed. Noisemeasurements were not betweenacceptable limits.

Active message example1.ATT105 APR01 12:00:00 2112 INFO

CKT CAMA2W 1

T100 NML: 10 NIAL: 20 NOISE: 12.0 Q1 PASS

Clear message examplen/a

Associated OM registers

ATT106The Automatic Trunk Testing (ATT) subsystem generates this report whena T102 trunk test is complete. The T102 test measures far-to-near end losson 102-type test lines.

The DMS and the far-end office install and execute T102 as follows:

• The DMS connects a transmission test trunk (TTT) level meter to theoutgoing trunk.

• The DMS transmits a test code to the far-end office.

• The far-end office responds with an off-hook signal when a milliwattgenerator connects to the test trunk.

• The far-end office applies a milliwatt tone to the test trunk.

• The DMS measures the signal strength and calculates the transmissionloss.

• The test terminates and the trunk becomes free.

There is no additional information

Remedial actionIf rslttxt = PASS, there is no required action.

452 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 453: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

If rslttxt = FAIL, refer to Card Replacement Procedures, for step-by-stepprocedures. Perform immediate action if qltxt = Q2.

AttributesAttribute Value

Severity Warning

Format1.ATT106 mmmdd hh:mm:ss ssdd INFO

CKT trkid

T102 EML: nn.n FN_DEV: nn.n qltxt

rslttxt

Selected field descriptionsField Value Fixed or

VariableDescription

INFO Constant Fixed Indicates that the following datagenerate this report when a T102trunk test is complete

CKT Symbolic text Variable Provides equipment identification forsuspect trunk equipment

T102 Constant Fixed Indicates system performed milliwattwith the 102-type test line

EML 0.0 to 36.0 Variable Provides expected measured loss(EML) in decibels. The EML valueappears in user data TableCLLIMTCE.DIAGDATA.

FN_DEV -99.9 to +99.9 dB Variable Provides far-to-near end lossdeviation in decibels. The fieldFN_DEV indicates the differencebetween measured loss on trunk andEML in decibels.

*** Variable Indicates that far-to-near enddeviation is greater than 99.9 dB

qltxt Blank Variable Indicates transmission measurementswere between acceptable limits

Q1 Variable Indicates transmission measurementswere between maintenance limits. Theuser must begin maintenance action.

ATT106 453

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 454: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Q2 Variable Indicates transmission measurementsexceeded immediate action limit. Theuser must begin immediatemaintenance action.

rslttxt PASS Variable Indicates test passed. Noise and lossmeasurements were betweenacceptable limits.

FAIL Variable Indicates test failed. Noise and lossmeasurements were not betweenacceptable limits.

Active message example1.ATT106 APR01 12:00:00 2112 INFO

CKT CAMA2W 1

T102 EML: 6.0 FN_DEV: 2.2 Q1

PASS

Clear message examplen/a

Associated OM registers

ATT107The Automatic Trunk Testing (ATT) subsystem generates this report whena T104 trunk test is complete. The T104 measures far-to-near end andnear-to-far end noise and loss.

The DMS and the far-end office install and execute N100 as follows:

• The DMS connects a transmission test trunk (TTT) level meter to theoutgoing trunk.

• The DMS transmits a test code to the far-end office.

• The far-end office responds with an off-hook signal when a milliwattgenerator connects to the test trunk.

• The DMS applies a milliwatt tone to the test trunk.

• The far-end measures the signal strength and calculates the loss.

• The far-end office applies a milliwatt tone to the test trunk.

• The DMS measures the signal strength and calculates the loss.

454 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 455: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• The far-end applies an attenuated milliwatt signal based on the near-to-far end loss.

• The DMS measures the attenuated signal loss and calculates the near-to-far end loss.

• The far-end office provides quiet termination to the trunk.

• The DMS measures the noise.

• The DMS provides quiet termination to the trunk.

• The far-end measures the noise.

• The test terminates and the trunk becomes free.

Remedial actionIf rslttxt = PASS, there is no action required.

If rslttxt = FAIL, refer to Card Replacement Procedures, for step-by-stepprocedures. Immediate action is required if qltxt = Q2.

AttributesAttribute Value

Severity Warning

Format1.ATT107 mmmdd hh:mm:ss ssdd INFO

CKT trkid

T104 EML: nn.n FN_DEV: nn.n NF_DEV: nn.n rslttxt

NML: nn NIAL: nn NOISE: nn.n NF_NSE: nftxt qltxt

Selected field descriptionsField Value Fixed or

VariableDescription

INFO Constant Fixed Indicates that the following datagenerate this report when a T104trunk test is complete

CKT Symbolic text Variable Provides equipment identification forsuspect trunk equipment

T104 Constant Fixed Indicates the system performed themilliwatt test in both directions andused the 104-type test line

ATT107 455

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 456: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

EML 0.0 to 36.0 Variable Provides expected measured loss(EML) in decibels. The EML valueappears in user data TableCLLIMTCE.DIAGDATA.

FN_DEV -99.9 to +99.9 dB Variable Provides far-to-near end lossdeviation in decibels. FN_DEVindicates difference betweenmeasured loss on trunk and EML indecibels.

*** Variable Indicates far-to-near end deviation isgreater than 99.9 dB.

NF_DEV -99.9 to +99.9 dB Variable Provides near-to-far end lossdeviation in decibels. NF_DEVindicates difference betweenmeasured loss on trunk and EML indecibels.

*** Variable Indicates near-to-far end deviation isgreater than 99.9 dB

rslttxt PASS Variable Indicates test passed. Noise and lossmeasurements were within acceptabletolerances.

FAIL Variable Indicates test failed. Noise and lossmeasurements were not withinacceptable tolerances.

NML 1 to 63 Variable Provides noise maintenance limit(NML) in decibels above referencenoise. The NML value appears in userdata Table CLLIMTCE.DIAGDATA. Ifthe noise measurement exceedsNML, the user should initiatemaintenance action.

NIAL 1 to 63 Variable Provides noise immediate action limit(NIAL) in decibels above referencenoise. The NIAL value appears in userdata Table CLLIMTCE.DIAGDATA. Ifthe noise measurement exceedsNIAL, the user must initiate immediateaction.

NOISE -99.9 to +99.9 Variable Provides accurate far-to-near endnoise measured on trunk in decibelsabove reference noise

456 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 457: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

NF_NSE PASS Variable Indicates that the accurate near-to-farend noise measured on trunk indecibels is less than 41 dBRN

FAIL Variable Indicates that the accurate near-to-farend noise measured on trunk indecibels is greater than 41 dBRN

qltxt Blank Variable Indicates transmission measurementswere within acceptable tolerances

Q1 Variable Indicates transmission measurementswere within maintenance limit. Theuser should initiate maintenanceaction.

Q2 Variable Indicates transmission measurementswere in excess of immediate actionlimit. The user must initiate immediatemaintenance action.

Active message example1.ATT107 JAN01 16:02:00 6298 INFO

CKT ODCMBX1 10

T104 EML: 6.0 FN_DEV: 1.6 NF_DEV: 0.1 PASS

NML: 10 NIAL: 20 NOISE: 11.0 NF_NSE: PASS Q1

Clear message examplen/a

Associated OM registers

ATT108The Automatic Trunk Testing (ATT) subsystem generates ATT 108 when aTLPA/TLPB trunk test is complete. These looparound trunk tests measurefar-to-near end and near-to-far end loss for a group of trunks.

The TLPA and TLPB selects two trunks as reference trunks from the groupof trunks the system tests. The far-to-near end loss is less than themaintenance limit on one reference trunk. The near-to-far end loss is lessthan the maintenance limit in the other reference trunk. The two trunksprovide a known transmission loss for the looparound test.

ATT108 457

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 458: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The DMS and the far-end office install and execute TLPA and TLPB asfollows:

• The DMS selects two reference trunks as follows:

• The DMS seizes a trunk and applies the T102 test. Refer to ATT106 formore information on T102-type trunk tests.

• When the trunk passes the T102 test, the trunk becomes the referencetrunk with a known far-to-near end loss. If the trunk fails the T102 test,the DMS seizes and tests another trunk.

• When the DMS selects the first reference trunk, the DMS seizes andtests a second trunk with a looparound test.

• When the trunk passes the looparound test, the trunk becomes thereference trunk with a known near-to-far end loss. If the trunk fails thelooparound test, the DMS seizes and tests another trunk.

• The DMS selects the reference trunks and connects a transmission testtrunk (TTT) level meter to the outgoing trunk.

• The DMS transmits a test code to the far-end office.

• The DMS applies a milliwatt tone to the test trunk. The signal loops onthe reference trunk with a known far-to-near end transmission loss.

• The DMS measures the signal strength and calculates the near-to-farend loss.

• The DMS applies a milliwatt tone to the reference trunk with a knownnear-to-far end transmission loss. The system loops the signal on thetest trunk.

• The DMS measures the signal strength and calculates the far-to-nearend loss.

Remedial actionIf rslttxt = PASS, there is no action required.

If rslttxt = FAIL, refer to Card Replacement Procedures, for step-by-stepprocedures. Immediate action is required if qltxt = Q2.

AttributesAttribute Value

Severity Warning

Format1.ATT108 mmmdd hh:mm:ss ssdd INFO

CKT trkid

458 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 459: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

tstnm EML: nn.n FN_DEV: nn.n NF_DEV: nn.n qltxt rslttxt

Selected field descriptionsField Value Fixed or

VariableDescription

INFO Constant Fixed Indicates that the following datagenerates this report when a TLPA/TLPB trunk test is complete

CKT Symbolic text Variable Provides equipment identification forsuspect trunk equipment

tstnm TLPA Variable Indicates that the system hasperformed the looparound test linetest. The reference trunk occupiesport 1 of TTT.

TLPB Variable Indicates that the system hasperformed the looparound test linetest. The reference trunk occupiesport 2 of TTT.

EML 0.0 to 36.0 Variable Provides expected measured loss(EML) in decibels. The EML valueappears in User Data TableCLLIMTCE.DIAGDATA.

FN_DEV -99.9 to +99.9 dB Variable Provides far-to-near end lossdeviation in decibels. FN_DEVindicates the difference betweenmeasured loss on trunk and EML indecibels.

*** Variable Indicates far-to-near end deviation isgreater than 99.9 dB

NF_DEV -99.9 to +99.9 dB Variable Provides near-to-far end lossdeviation in decibels. Field NF_DEVindicates the difference betweenmeasured loss on trunk and EML indecibels.

*** Variable Indicates near-to-far end deviation isgreater than 99.9 dB

qltxt Blank Variable Indicates transmission measurementsare in acceptable tolerances

Q1 Variable Indicates transmission measurementsare in the maintenance limit. The usermust initiate maintenance action.

ATT108 459

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 460: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Q2 Variable Indicates transmission measurementsare in excess of immediate actionlimit. The user must initiate immediateaction.

rslttxt PASS Variable Indicates test passes. Noise and lossmeasurements are in acceptabletolerances.

FAIL Variable Indicates test fails. Noise and lossmeasurements are not in acceptabletolerances.

Active message example1.ATT108 APR23 16:16:16 2346 INFO

CKT ODCMBX1 3

TLPA EML: 6.0 FN_DEV: -.3 NF_DEV: 2.3 Q1 FAIL

Clear message examplen/a

Associated OM registers

ATT109The Automatic Trunk Testing (ATT) subsystem report ATT109. Thesubsystem generates ATT109 when it initiates a trunk group test.

The definition for variables used to represent time in ATT109 are asfollows:

• day - Day of month (0-31)

• hour - Hour of day (0-23)

• min - Minute of hour (0-59)

• qmonth - Month of quarter (0-2)

• smonth - Month of semi-year (0-6)

• wk - Week of month (1 to 5)

• wkday - Day of week (0 = Monday, 1 = Tuesday, 2 = Wednesday, 3 =Thursday, 4 = Friday, 5 = Saturday, and 6 = Sunday)

Remedial actionn/a

460 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 461: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatATT109 mmmdd hh:mm:ss ssdd INFO GRP cllinm

ATT GRP START TEST SUMMARY START

seqtxt TEST: tstnm sigtxt meastxt

START: sttxt MAXTEST: nnnnn DELAY: dlytxt

WAITTIME: n REMOVE: b RMV25PC: b LOG: logtxt

RETEST: rtsttxt

BERQ: berq SLIPSQ :n

ERSQ: n% DURATION : nMINS

RANGE: rngtxt RECYCLE: nn LOGSKIP: skiptxt

Selected field descriptionsField Value Fixed or

VariableDescription

T5SB Variable Indicates the system performed areturn loss test with self-check. Thesystem used a 105-type test line.

T50L Variable Indicates the system performed a loss(1004 Hz at 0 dBm) and return loss(C1004 Hz at 0 dBm) test. The systemused a 105-type test line.

T56N Variable Indicates the system performed a loss(404, 1004, and 2804 Hz at -16 dBm),noise (C_notched filter), and returnloss test. The system used a 105-typetest line.

sigtxt BSY Variable Indicates the system performed abusy-flash test for the ATME2 set oftests.

FUL BSY Variable Indicates the system performed a fullbusy-flash test for the ATME2 set oftests.

ATT109 461

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 462: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

FULL Variable Indicates the system performed a fullsignaling test for the ATME2 set oftests.

NONE Variable Indicates the system performed a nosignaling test for the ATME2 set oftests.

SHORT Variable Indicates the system performed ashort signaling test for the ATME2 setof tests.

SHORT BSY Variable Indicates the system performed ashort busy-flash test for the ATME2set of tests.

meastxt L Variable Indicates the system performed a lossmeasurement test at 0 dB and 1004Hz for the ATME2 set of tests.

L N Variable Indicates the system performed a lossand noise measurement test for theATME2 set of tests.

LFD Variable Indicates the system performed a lossfrequency deviation measurementtest. Loss frequency deviationmeasurement test is at -16 dB and404, 1004, and 2804 Hz for theATME2 set of tests.

LFD N Variable Indicates the system performed a lossfrequency deviation and noisemeasurement test. The noisemeasurement test uses a C-notchedfilter for the ATME2 set of tests.

N Variable Indicates the system performed anoise measurement test with a C-message filter for the ATME2 set oftests.

NONE Variable Indicates the system did not performtransmission measurement tests. Thesystem only performed the ATME2signaling test.

START: sttxt DLY hour min Variable Indicates the test is scheduled on adaily base. Refer to Additionalinformation for a definition of timevalues.

462 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 463: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

DYOM day hour min Variable Indicates the test is scheduled on oneday of each month. Refer to Additionalinformation for a definition of timevalues.

EDY hour min Variable Indicates the test is scheduled oneven days. Refer to Additionalinformation for a definition of time,values.

EVM wk wkday hourmin

Variable Indicates the test is scheduled oneven months. Refer to Additionalinformation for definition of timevalues.

EWK wkday hour min Variable Indicates the test is scheduled oneven weeks. Refer to Additionalinformation for a definition of timevalues.

HRY min Variable Indicates the test is scheduled forevery hour. Refer to Additionalinformation for a definition of timevalues.

IMMED Variable Indicates the test is to beginimmediately. IMMED only displayswhen the user initiates the testmanually from automatic trunk testing(ATT) at the MAP level.

IQT qmonth wk wkdayhour min

Variable Indicates the test is scheduled everythree months. Refer to Additionalinformation for a definition of timevalues.

MTH wk wkday hourmin

Variable Indicates the test is scheduled everymonth. Refer to Additional informationfor definition of time values.

ODM wk wkday hourmin

Variable Indicates the test is scheduled everyodd month. Refer to Additionalinformation for definition of timevalues.

ODY hour min Variable Indicates the test is scheduled everyodd day. Refer to Additionalinformation for definition of timevalues.

ATT109 463

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 464: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

OWK wkday hour min Variable Indicates the test is scheduled everyodd week. Refer to Additionalinformation for definition of timevalues.

QTR qmonth day hourmin

Variable Indicates the test is scheduled everythree months. Refer to Additionalinformation for definition of timevalues.

SYR smonth wkwkday hour min

Variable Indicates the test is scheduled everysix months. Refer to Additionalinformation for definition of timevalues.

WKY wkday hour min Variable Indicates the test is scheduled onevery week. Refer to Additionalinformation for definition of timevalues.

MAXTEST: nnnnn 0-32767 Variable Provides the maximum time inminutes that the test for a trunk groupcan run for.

DELAY: dlytxt EXLONGDLY Variable Indicates that the time delay betweeneach trunk test is 15 seconds.

LONGDLY Variable Indicates that the time delay betweeneach trunk test is nine seconds.

MEDDLY Variable Indicates that the time delay betweeneach trunk test is six seconds.

SHORTDLY Variable Indicates that the time delay betweeneach trunk test is one second.

WAITTIME: n 0-7 Variable Indicates the minutes that the systemwaits for trunk circuits that are notavailable at the time of the test.

REMOVE: b Y Variable Indicates that the DMS removes atrunk circuit from service if the testfails.

N Variable Indicates that the DMS does notremove a trunk circuit from service ifthe test fails.

RMV25PC: b Y Variable Indicates that the DMS can removemore than 25% of trunk circuits fromservice if the circuits fail the test.

N Variable Indicates the DMS can not removemore than 25% of trunk circuits fromservice if the circuits fail the test.

464 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 465: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

LOG: logtype ALL Variable Indicates the system reports all testresults as logs.

FL Variable Indicates the system only reports testfailures as logs.

Q1 Variable Indicates the system only reports testfailures or tests that exceedmaintenance limit as logs.

Q2 Variable Indicates the system only reports testfailures or tests that exceed theimmediate action limit as logs.

RETEST: rtsttxt ALL Variable Indicates the system retests trunkcircuits that fail any of the ATME2tests.

BSY FLASH FAIL Variable Indicates the system retests trunkcircuits that fail the ATME2 busy-flashtest.

BUSY FAR END Variable Indicates the system retests trunkcircuits in which the far-end office isbusy for the ATME2 tests.

BUSY NEAR END Variable Indicates the system retests trunkcircuits in which the near-end is busyfor the ATME2 tests.

INSTAB INTERM Variable Indicates the system retests all trunkcircuits that show instability ordifficulties for any ATME2 type test.

MEAS Q1 FAIL Variable Indicates the system retests trunkcircuits that exceed the maintenancelimit of the ATME2 tests.

MEAS Q2 FAIL Variable Indicates the system retests trunkcircuits that exceed the immediateaction limit of the ATME2 tests.

MISC FAILURE Variable Indicates the system retests trunkcircuits that show miscellaneoustroubles for the ATME2 tests.

N Variable Indicates the ATT subsystem does notretest a failed trunk circuit.

SIG FAILURE Variable Indicates the system retests trunkcircuits that fail the ATME2 signalingtests.

Y Variable Indicates the system retested a trunkcircuit.

ATT109 465

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 466: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

BERQ : berq A number expressedin scientific notation.

Variable Provides the Q limit for the bit errorrate test line (BERTL). The number1.1 *10E-3 means .0011.

SLIPSQ : n Integer Variable Indicates the number of slips Q limit.

ERSQ : n % 0-100 Variable Provides the error seconds Q limit.

DURATION : n Integer Variable Provides the duration of the BERTL inminutes.

RANGE: rngtxt ALL Variable Indicates that system tests all circuitsin trunk group. Displayed only fortrunk tests initiated from ATT MAPlevel.

n1-n2 Variable Provides circuit numbers for trunksthat are tested. Displayed only fortrunk tests initiated from ATT MAPlevel.

The value n1, n2 = circuitnumber(0-10000).

RECYCLE: nn 0-99 Variable Indicates the number of times testequipment recycles through circuits intrunk group. Displays only for trunktests initiated from ATT MAP level.

LOGSKIP: b Y Variable Indicates the system has notgenerated a report of results. Displaysonly for trunk tests initiated from ATTMAP level.

N Variable Indicates the system generates areport of results. Displayed only fortrunk tests initiated from ATT MAPlevel.

GRP cllinm Table CLLI Variable Provides Common Language LocationIdentifier (CLLI) for trunk group. ListCLLI from CI MAP level for list ofoffice CLLI.

ATT GRP STARTTEST SUMMARY

Constant Fixed Indicates report summarizes startingparameters for a trunk group test.

seqtxt ATME, ATME1 Variable Indicates the system tested a trunkgroup, and used automatictransmission measuring equipment(ATME).

MANUAL,MANUALLY

Variable Indicates the system tested a trunkgroup as a result of a command thatthe user entered at ATT MAP level.

466 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 467: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

PERIODIC,PERIODIC1

Variable Indicates the system tested a trunkgroup based on a periodic schedule.

QUARTERLY Variable Indicates the system tested a trunkgroup at three-month intervals.

SEMIANNUAL Variable Indicates the system tested a trunkgroup at semi-annual intervals.

tstnm DIAG Variable Indicates the system performed anextended diagnostic test.

MXAM Variable Indicates the system performed themobile telephone exchange (MTX)audio loop test with C-message filter.

MXAN Variable Indicates the system performed theMTX audio loop test with C-notchfilter.

MXRM Variable Indicates the system performed theMTX radio frequency loop test with C-message filter.

MXRN Variable Indicates the system performed theMTX radio frequency loop test with C-notch filter.

MXWM Variable Indicates the system performed theMTX wire loop test with C-messagefilter.

MXWN Variable Indicates the system performed theMTX wire loop test with C-notch filter.

N100 Variable Indicates the system performed thenew version of milliwatt and balancetest. The system used a 100-type testline.

S100 Variable Indicates the system only performedthe old version of the balance test.The system used the 100-type testline.

TART Variable Indicates the system performed theTurkey arter test line test.

TA01 Variable Indicates the system performed atransmission test of levelmeasurements in both directions. Thesystem used ATME.

ATT109 467

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 468: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TA02 Variable Indicates the system performed atransmission test of loss frequencydeviation. The system used ATME.

TA03 Variable Indicates the system performed atransmission test of noisemeasurements. The system usedATME.

TA04 Variable Indicates the system performed atransmission test of levelmeasurements in both directions andnoise measurements. The systemused ATME.

TA05 Variable Indicates the system performed atransmission test of loss frequencydeviation and noise measurements.The system used ATME.

TA06 Variable Indicates the system performed a fullsignaling test. The system usedATME.

TA07 Variable Indicates the system performed a fullsignaling test and a transmission testof level measurements in bothdirections. The system used ATME.

TA08 Variable Indicates the system performed a fullsignaling test and a transmission testof loss frequency deviation. Thesystem used ATME.

TA09 Variable Indicates the system performed a fullsignaling test and a transmission testof noise measurements. The systemused ATME.

TA10 Variable Indicates the system performed a fullsignaling test, a transmission test oflevel measurements in both directions,and noise measurements. The systemused ATME.

TA11 Variable Indicates the system performed a fullsignaling test, a transmission test ofloss frequency deviation, and noisemeasurements. The system usedATME.

468 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 469: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TA12 Variable Indicates the system performed ashort signaling test. The system usedATME.

TA13 Variable Indicates the system performed abusy-flash signaling test. The systemused ATME.

TA14 Variable Indicates system performed a busy-flash signaling test and a transmissiontest of level measurements in bothdirections. The system used ATME.

TA15 Variable Indicates the system performed abusy-flash signaling test and atransmission test of loss frequencydeviation. The system used ATME.

TA16 Variable Indicates the system performed abusy-flash signaling test and atransmission test of noisemeasurements. The system usedATME.

TA17 Variable Indicates the system performed abusy-flash signaling test, atransmission test of levelmeasurements in both directions, andnoise measurements. The systemused ATME.

TA18 Variable Indicates the system performed abusy-flash signaling test, atransmission test of loss frequencydeviation, and noise measurements.The system used ATME.

TA19 Variable Indicates the system performed a fullsignaling test and a busy-flashsignaling test. The system usedATME.

TA20 Variable Indicates the system performed a fullsignaling test. The system performeda busy-flash signaling test, and atransmission test of levelmeasurements in both directions. Thesystem used ATME.

ATT109 469

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 470: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TA21 Variable Indicates the system performed a fullsignaling test, a busy-flash signalingtest, and a transmission test of lossfrequency deviation. The system usedATME.

TA22 Variable Indicates the system performed a fullsignaling test, a busy-flash signalingtest, and a transmission test of noisemeasurements. The system usedATME.

TA23 Variable Indicates the system performed thefull signaling test. The systemperformed a busy-flash signaling test,a transmission test of levelmeasurements in both directions, andnoise measurements. The systemused ATME.

TA24 Variable Indicates the system performed a fullsignaling test. The system performeda busy-flash signaling test, and atransmission test of noisemeasurements and loss frequencydeviation. The system used ATME.

TA25 Variable Indicates the system performed ashort signaling test and a busy-flashsignaling test. The system usedATME.

TB08 Variable Indicates the system performed a biterror rate test line test (BERTL) at 56Kbits every second. The system used a2047 bit pattern.

TB18 Variable Indicates the system performed aBERTL at 64K bits every second. Thesystem used a 2047 bit pattern.

TCON Variable Indicates the system performed aCommon Channel Inter-officeSignaling No. 6 (CCIS #6) continuitytest.

TCOT Variable Indicates the system performed aCCIS #6 continuity test (new versionon digital trunk controller (DTC).

TE_M Variable Indicates the system performed an Eand M lead signaling test.

470 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 471: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TLPA Variable Indicates the system performed a looparound test line test. The referencetrunk occupies port 1 of transmissiontest trunk (TTT).

TLPB Variable Indicates the system performed a looparound test line test. The referencetrunk occupies port 2 of transmissiontest trunk (TTT).

TLON Variable Indicates the system performed a loss(1004 Hz at 0 dBm) and noise(C_message filter) test. The systemused a 105-type test line.

TLOS Variable Indicates the system performed a loss(1004 Hz at 0 dBm) test with anautomatic check. The system used a105-type test line.

TL05 Variable Indicates the system performed a loss(1004 Hz at 0 dBm) test, the systemused a 105-type test line.

TL6N Variable Indicates the system performed a loss(404, 1004, and 2804 Hz at -16 dBm)and noise (C_notched filter) test. Thesystem used a 105-type test line.

TL6S Variable Indicates the system performed a loss(404, 1004, and 2804 Hz at -16 dBm)test with an automatic check. Thesystem used a 105-type test line.

TL65 Variable Indicates the system performed a loss(404, 1004, and 2804 Hz at -16 dBm)test. The system used a 105-type testline.

TNSS Variable Indicates the system performed a non-synchronous test line test.

TR2L Variable Indicates the system performed arepeat two long delay test.

TR2S Variable Indicates the system performed arepeat two short delay test.

TSBS Variable Indicates the system performed a far-end equipment self-check of loss(404, 1004, and 2804 Hz test tone at-16 dB). Indicates the systemperformed a far-end equipment self-check of noise (C_notched filter), and

ATT109 471

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 472: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

a return loss test. The system used a105-type test line. TSBT Indicates thesystem performed a return lossmeasurement test.

TSYN Variable Indicates the system performed asynchronous test line test.

TS65 Variable Indicates the system performed a far-end equipment self-check of loss(404, 1004, and 2804 Hz test tone at-16 dB). Indicates the systemperformed a far-end equipment self-check of noise (C-notched filter). Thesystem used 105-type test line.

T100 Variable Indicates the system performed amilliwatt and balance test. The systemused a 100-type test line, but theversion (old or new) is not known.

T102 Variable Indicates the system performed amilliwatt test. The system used a 102-type test line.

T103 Variable Indicates the system performed asignaling test. The system used a103-type test line.

T104 Variable Indicates the system performed amilliwatt test in both directions. Thesystem used a 104-type test line.

T105 Variable Indicates the system performed a loss(1004 Hz at 0 dBm) and noise (C-message filter) test with automaticcheck. The system used a 105-typetest line.

T165 Variable Indicates the system performed a loss(404, 1004, and 2804 Hz at -16 dBm)test with automatic check. The systemperformed a noise (C-notched filter)test with automatic check. The systemused a 105-type test line.

T5AS Variable Indicates the system performed a loss(1004 Hz at 0 dBm), and noise (C-message filter) test. The systemperformed a return loss test withautomatic check. The system used a105-type test line.

472 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 473: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

T5AT Variable Indicates the system performed a loss(C1004 Hz at 0 dBm), and noise (C-message filter) test. The systemperformed and return loss (C1004 Hzat 0 dBm) test. The system used a105-type test line.

T5BS Variable Indicates the system performed areturn loss measurement and a selfcheck test. The system used a 105-type test line.

T5LB Variable Indicates the system performed a loss(404, 1004, and 2804 Hz at -16 dBm)and return loss test. The system useda 105-type test line.

Active message exampleATT109 DEC13 05:08:41 2146 INFO GRP OTMF1

ATT GRP START TEST SUMMARY

START

MANUAL TEST: TL6N FULL L

START: IMMED MAXTEST: 0 DELAY: SHORTDLY

WAITTIME: 0 REMOVE: N RMV25PC: N LOG: ALL

RETEST: N

BERQ : 1.1 * 10E-3 SLIPSQ : 3

ERSQ : 8 % DURATION : 900 MINS

RANGE: ALL RECYCLE: 1 LOGSKIP: N

Clear message examplen/a

ATT109 473

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 474: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ATT110The Automatic Trunk Testing (ATT) subsystem report ATT110. Thesubsystem generates ATT110 when a group trunk test terminatesnormally. The ATT110 report identifies the test and summarizes theresults.

The summary report spans a series of different types of trunk tests. Thereport display is different for each type of test.

A group trunk test can include a transmission noise and loss test. Thesetest results appear in a loss table (losstable) or in a noise table(noisetable). Each table contains bins. The bins in a loss table are basedon the loss deviation from the expected measured loss (EML). The bins ina noise table are based on the noise deviation from the noise maintenancelimit (NML). When the subsystem makes loss measurements for more thanone frequency, the report summarizes loss deviation for each frequency.

The group-trunk test can be part of the automatic transmission measuringequipment (ATME2) test. In this occurrence, the system tabulates theresults according to type of failure.

-4.8 AND LOWER n1 n2 n3

-4.7 THROUGH-4.3 n1 n2 n3

-4.2 THROUGH-3.8 n1 n2 n3

-3.7 THROUGH-3.3 n1 n2 n3

-3.2 THROUGH-2.8 n1 n2 n3

-2.7 THROUGH-2.3 n1 n2 n3

-2.2 THROUGH-1.8 n1 n2 n3

-1.7 THROUGH-1.3 n1 n2 n3

-1.2 THROUGH-0.8 n1 n2 n3

-0.7 THROUGH-0.3 n1 n2 n3

-0.2 THROUGH 0.2 n1 n2 n3

0.3 THROUGH 0.7 n1 n2 n3

474 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 475: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

0.8 THROUGH 1.2 n1 n2 n3

1.3 THROUGH 1.7 n1 n2 n3

1.8 THROUGH 2.2 n1 n2 n3

2.3 THROUGH 2.7 n1 n2 n3

2.8 THROUGH 3.2 n1 n2 n3

3.3 THROUGH 3.7 n1 n2 n3

3.8 THROUGH 4.2 n1 n2 n3

4.3 THROUGH 4.7 n1 n2 n3

4.8 AND HIGHER n1 n2 n3

Table Loss Measurement identifies the number of trunks that have a givenloss deviation compared to the expected measured loss. The categories orbins, for example, 0.8 THROUGH 1.2, are constant. The frequencycolumns (n1, n2, and n3) and (0 to 32767) indicate the number of trunkcircuits in each bin for different frequencies. The table Loss Measurementhas one or three frequency columns. The number of frequenciesassociated with a test determine the number of columns.

• For transmission loss tests performed at 0/-10 dB, the table displaysone frequency (1004 Hz) measurement.

• For transmission loss tests performed at -10/-16 dB, the table displaysthree frequency (404, 1004, and 2804 Hz) measurements.

8 AND LOWER nnnnn

7 THROUGH -5 nnnnn

4 THROUGH -2 nnnnn

1 THROUGH 1 nnnnn

2 THROUGH 4 nnnnn

5 THROUGH 7 nnnnn

8 THROUGH 10 nnnnn

11 THROUGH 13 nnnnn

ATT110 475

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 476: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

14 AND HIGHER nnnnn

Table Noise identifies the number of trunks that have a given noisedeviation compared to the noise maintenance limit. The categories or binsare constant. For example, 8 THROUGH 10. The frequency column nnnnn(for 0 to 32767) indicates the number of trunk circuits in each bin for thefrequency. The filter used determines the frequency.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

Format1.ATT110 mmmdd hh:mm:ss ssdd INFO GRP clli

ATT GRP TEST SUMMARY. TEST: testnm SUMMARY

TESTEQ:trkid TIG:nnnnn TESTED:nnn% FLTEST:nnn% SKIPPED:nnn%

PASSED = nnnnn SIG_FAIL = nnnnn BSY_FAIL = nnnnn

Q1_FAIL = nnnnn Q2_FAIL = nnnnn NE_BSY = nnnnn

FE_BSY = nnnnn INST_INT = nnnnn MISC_FAIL = nnnnn

LOSS DEVIATION IN DB (MEAS AT n1/n2 DB freq1 freq2 freq3 HZ)

losstable

NOISE DEVIATION IN DBRN (MEAS fltrtxt)

noisetable

476 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 477: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

T50L Variable Indicates the system performed theloss (1004 Hz at 0 dBm) and returnloss (C1004 Hz at 0 dBm) test.Indicates the system used a 105-typetest line.

T56N Variable Indicates the system performed theloss (404, 1004, and 2804 Hz at -16dBm), noise (C_notched filter), andreturn loss test. Indicates the systemused a 105-type test line.

SUMMARY Constant Fixed Indicates that the report is a group testsummary for trunk groups that theATT subsystem tested.

TESTEQ: trkid Symbolic text Variable Provides equipment identification fortest equipment used for group trunktesting. Refer to Table I.

TIG: nnnnn -32768- +32767 Variable Indicates the number of trunks in thetest group.

TESTED: nnn% 0-100 % Variable Indicates the percentage of test trunksin the group.

FAILED: nnn% 0-100 % Variable Indicates the percentage of trunks inthe group that failed the test.

SKIPPED: nnn% 0-100 % Variable Indicates the percentage of skippedtrunks in the group.

PASSES = nnnnn 0-32767 Variable Indicates the number of trunks thatpass the ATME2 trunk test. This fieldappears only for ATME2-type trunktests.

SIG_FAIL = nnnnn 0-32767 Variable Indicates the number of trunks that failthe ATME2 trunk test because of asignaling test failure. This fieldappears only for the ATME2-typetrunk test.

BSY_FAIL = nnnnn 0-32767 Variable Indicates the number of trunks that failthe ATME2 trunk test because of abusy-flash test failure. This fieldappears only for the ATME2-typetrunk test.

ATT110 477

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 478: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Q1_FAIL = nnnnn 0-32767 Variable Indicates the number of trunks thatexceed the maintenance limit fortransmission measurements of theATME2 trunk test. This field appearsonly for the ATME2-type trunk test.

Q2_FAIL = nnnnn 0-32767 Variable Indicates the number of trunks thatexceed the immediate action limit forthe transmission measurements of theATME2 trunk test. This field appearsonly for the ATME2-type trunk test.

NE_BSY = nnnnn 0-32767 Variable Indicates the number of trunks that thesystem cannot test because the trunksare near-end busy. This field appearsonly for the ATME2-type trunk test.

FE_BSY = nnnnn 0-32767 Variable Indicates the number of trunks that thesystem cannot test because the trunksare far-end busy. This field appearsonly for the ATME2-type trunk test.

INST_INT = nnnnn 0-32767 Variable Indicates the number of trunks thatfailed the ATME2 trunk test becauseof an instability or problem. This fieldappears only for ATME2-type trunktests.

MISC_FAIL = nnnnn 0-32767 Variable Indicates the number of trunks thatfailed the ATME2 trunk test becauseof miscellaneous problems. This fieldappears only for ATME2-type trunktests.

LOSS DEVIATION INDB (MEAS ATmeastxt)

0/-10 DB 1004Hz Variable Provides the heading for a lossdeviation table. This table displaysloss measurements that use a testtone at 1004 Hz and 0/-10 dB. TableLoss measurement appears only for apart of T105-type trunk tests. The lossmeasurement table can appear inconjunction with NOISE DEVIATIONIN DBRN (MEAS C-MESSAGE) noisetable.

LOSS DEVIATION INDB (MEAS ATmeastxt)

-10/-16 DB AND AT404 1004 2804 HZ

Variable Provides the heading for a lossdeviation table. The table displaysloss measurements that use a set oftest tones at 404, 1004, and 2804 Hzand -10/-16 dB. The report only printsTable Loss Measurement for some

478 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 479: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

T105-type trunk tests. The system canoutput the loss measurement table inconjunction with the NOISEDEVIATION IN DBRN (MEAS C-NOTCHED) noise table.

losstable Symbolic text Variable Refer to the Additional Informationsection.

NOISE DEVIATIONIN DBRN (MEASfltrtxt)

C_MESSAGE Variable Provides the heading for the noisedeviation table when the test uses aC-message filter and a bandpass filterover the voice frequency range.

C_NOTCHED Variable Provides the heading for the noisedeviation table when the test uses aC-notched filter that attenuates onlytest tone frequency. This filter makessure noise measurements areaccurate.

noisetable Symbolic text Variable Refer to the Additional Informationsection.

TL6N Variable Indicates the system performed theloss (404, 1004, and 2804 Hz at -16dBm) and noise (C_notched filter)test. Indicates the system used a 105-type test line.

TL6S Variable Indicates the system performed theloss (404, 1004, and 2804 Hz at -16dBm) test with automatic check.Indicates the system used a 105-typetest line.

TL65 Variable Indicates the system used a 105-typetest line to perform the loss (404,1004, and 2804 Hz at -16 dBm) test.

TNSS Variable Indicates the system performed thenon-synchronous test line test.

TR2L Variable Indicates the system performed therepeat two long delay test.

TR2S Variable Indicates the system performed therepeat two short delay test.

TSBS Variable Indicates the system performed thefar-end equipment self-check of loss(404, 1004, and 2804 Hz test tone at

ATT110 479

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 480: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

-16 dBm), noise (C_notched filter),and return loss test. Indicates thesystem used a 105-type test line.

TSBT Variable Indicates the system performed thereturn loss measurement test.

TSYN Variable Indicates the system performed thesynchronous test line test.

TS65 Variable Indicates the system performed thefar-end equipment self-check of loss(404, 1004, and 2804 Hz test tone at-16 dBm) and noise (C_notched filter).Indicates the system used a 105-typetest line.

T100 Variable Indicates the system performed themilliwatt and balance test. Indicatesthe system used a 100-type test lineand the version (old or new) is notknown.

T102 Variable Indicates the system performed themilliwatt test. The system used a 102-type test line.

T103 Variable Indicates the system used a 103-typetest line to perform the signaling test.

T104 Variable Indicates the system used a 104-typetest line to perform the milliwatt test inboth directions.

T105 Variable Indicates the system performed theloss (1004 Hz at 0 dBm) and noise(C_message filter) test with automaticcheck. Indicates the system used a105-type test line.

T165 Variable Indicates the system performed theloss (404, 1004, and 2804 Hz at -16dBm) and noise (C_notched filter) testwith automatic check. Indicates thesystem used a 105-type test line.

T5AS Variable Indicates the system performed theloss (1004 Hz at 0 dBm), noise(C_message filter), and return losstest with automatic check. Indicatesthe system used a 105-type test line.

480 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 481: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

T5AT Variable Indicates the system performed theloss (C1004 Hz at 0 dBm), noise(C_message filter), and return loss(C1004 Hz at 0 dBm) test. Indicatesthe system used a 105-type test line.

T5BS Variable Indicates the system used a 105-typetest line to perform a return lossmeasurement and self check test.

T5LB Variable Indicates the system performed theloss (404, 1004, and 2804 Hz at -16dBm) and return loss test. Indicatesthe system used a 105-type test line.

T5SB Variable Indicates the system used a 105-typetest line to perform the return loss testwith self-check.

GRP clli Table CLLI Variable Provides the common languagelocation identifier (CLLI) for the trunkgroup. The field lists CLLI from ClMAP level for the list of off ice CLLI.

ATT GRP TESTSUMMARY

Constant Fixed Indicates report is a group testsummary for trunk groups that anautomatic trunk test (ATT) systemtests.

tstnm DIAG Variable Indicates the system performed theextended diagnostic test.

MXAM Variable Indicates the system performed themobile telephone exchange (MTX)audio loop test with C-message filter.

MXAN Variable Indicates the system performed theMTX audio loop test with C-notchfilter.

MXRM Variable Indicates the system performed theMTX radio frequency loop test with C-message filter.

MXRN Variable Indicates the system performed theMTX radio frequency loop test with C-notch filter.

MXWM Variable Indicates the system performed theMTX wire loop test with C-messagefilter.

MXWN Variable Indicates the system performed theMTX wire loop test with C-notch filter.

ATT110 481

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 482: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

N100 Variable Indicates the system used the 100-type test line to perform the newversion of the milliwatt and balancetest.

S100 Variable Indicates the system used the 100-type test line to perform only the oldversion of balance test.

TART Variable Indicates the system performed aTurkey arter test line test.

TA01 Variable Indicates the system performed atransmission test of levelmeasurements in both directions.Indicates the system used automatictransmission measuring equipment(ATME).

TA02 Variable Indicates the system used ATME toperform a transmission test of lossfrequency deviation.

TA03 Variable Indicates the system used ATME toperform a transmission test of noisemeasurements.

TA04 Variable Indicates the system used ATME toperform a transmission test of levelmeasurements in both directions andnoise measurements.

TA05 Variable Indicates the system used ATME toperform a transmission test of lossfrequency deviation and noisemeasurements.

TA06 Variable Indicates the system used ATME toperform a full signaling test.

TA07 Variable Indicates the system used ATME toperform a full signaling test andtransmission test of levelmeasurements in both directions.

TA08 Variable Indicates the system used ATME toperform a full signaling test andtransmission test of loss frequencydeviation.

TA09 Variable Indicates the system used ATME toperform a full signaling test andtransmission test of noisemeasurements.

482 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 483: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TA10 Variable Indicates the system performed a fullsignaling test, transmission test oflevel measurements in both directions,and noise measurements. The systemused ATME.

TA11 Variable Indicates the system performed a fullsignaling test, a transmission test ofloss frequency deviation, and noisemeasurements. The system usedATME.

TA12 Variable Indicates the system used ATME toperform a short signaling test.

TA13 Variable Indicates the system used ATME toperform a busy-flash signaling test.

TA14 Variable Indicates the system performed abusy-flash signaling test and atransmission test of levelmeasurements in both directions. Thesystem used ATME.

TA15 Variable Indicates the system used ATME toperform a busy-flash signaling testand a transmission test of lossfrequency deviation.

TA16 Variable Indicates the system used ATME toperform a busy-flash signaling testand a transmission test of noisemeasurements.

TA17 Variable Indicates the system performed abusy-flash signaling test, atransmission test of levelmeasurements in both directions, andnoise measurements. Indicates thesystem used ATME.

TA18 Variable Indicates the system performed abusy-flash signaling test, atransmission test of loss frequencydeviation, and noise measurements.The system used ATME.

TA19 Variable Indicates the system used ATME toperform a full signaling test and abusy-flash signaling test.

ATT110 483

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 484: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TA20 Variable Indicates the system performed a fullsignaling test, a busy-flash signalingtest, and a transmission test of levelmeasurements in both directions.Indicates the system used ATME.

TA21 Variable Indicates the system performed a fullsignaling test, a busy-flash signalingtest, and a transmission test of lossfrequency deviation. Indicates thesystem used ATME.

TA22 Variable Indicates the system performed a fullsignaling test, a busy-flash signalingtest, and a transmission test of noisemeasurements. Indicates the systemused ATME.

TA23 Variable Indicates the system performed a fullsignaling test, a busy-flash signalingtest, a transmission test of levelmeasurements in both directions, andnoise measurements. Indicates thesystem used ATME.

TA24 Variable Indicates the system performed a fullsignaling test, a busy-flash signalingtest, a transmission test of noisemeasurements and loss frequencydeviation. Indicates the system usedATME.

TA25 Variable Indicates the system used ATME toperform a short signaling test and abusy-flash signaling test.

TCON Variable Indicates the system performed theCCIS #6 continuity test.

TCOT Variable Indicates the system performed theCCIS #6 continuity test for the newversion on digital trunk controller(DTC).

TE_M Variable Indicates the system performed the Eand M lead signaling test.

TLPA,TLPB Variable Indicates the system performed theloop around test-line test.

484 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 485: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TL0N Variable Indicates the system performed theloss (1004 Hz at 0 dBm) and noise(C_message filter) test. Indicates thesystem used a 105-type test line.

TL0S Variable Indicates the system performed theloss (1004 Hz at 0 dBm) test withautomatic check. Indicates the systemused a 105-type test line.

TL05 Variable Indicates the system used a 105-typetest line to perform the loss (1004 Hzat 0 dBm) test.

Active message example1.ATT100 DEC1305:13:37 8702 INFO GRP OTMF1

ATT GRP TEST SUMMARY. TEST: T5AT SUMMARY

TESTEQ:TTU 1 TIG:-8680 TESTED: 0% FLTEST: 0% SKIPPED: 0%

LOSS DEVIATION IN DB (MEAS AT 0/-10 DB 1004 HZ)

Left Margin = 0.60 inches, First Indent =

0 inches>-4.8 AND LOWER 0

-4.7 THROUGH -4.3 0

-4.2 THROUGH -3.8 0

-3.7 THROUGH -3.3 0

-3.2 THROUGH -2.8 0

-2.7 THROUGH -2.3 0

-2.2 THROUGH -1.8 0

-1.7 THROUGH -1.3 0

-1.2 THROUGH -0.8 0

-0.7 THROUGH -0.3 1

-0.2 THROUGH 0.2 1

ATT110 485

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 486: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

0.3 THROUGH 0.7 0

0.8 THROUGH 1.2 0

1.3 THROUGH 1.7 0

1.8 THROUGH 2.2 0

2.3 THROUGH 2.7 0

2.8 THROUGH 3.2 0

3.3 THROUGH 3.7 0

3.8 THROUGH 4.2 0

4.3 THROUGH 4.7 0

4.8 AND HIGHER 0

NOISE DEVIATION IN DBRN (MEAS C-MESSAGE)

Left Margin = 0.60 inches, First Indent =

0 inches>-8 AND LOWER 2

-7 THROUGH -5 0

-4 THROUGH -2 0

-1 THROUGH 1 0

2 THROUGH 4 0

5 THROUGH 7 0

8 THROUGH 10 0

11 THROUGH 13 0

14 AND HIGHER 0

Clear message examplen/a

486 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 487: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ATT111The Automatic Trunk Testing (ATT) subsystem generates ATT111 whenthe number of groups the ATT subsystem can test at the same time ischanged.

The ATT subsystem normally tests multiple groups of trunks at the sametime. The number of groups of trunks tested at the same time can change.Enter a command at the ATT MAP level to change the number.

There is no additional information

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatATT111 mmmdd hh:mm:ss ssdd INFO ATT SIMULTANEOUS TESTS

RESET FROM n1 TO n2 SIZE

Selected field descriptionsField Value Fixed or

VariableDescription

INFO ATTSIMULTANEOUSTESTS RESETFROM n1 TO n2 SIZE

0 to 14 Variable Indicates change in the number oftrunk groups that can test at the sametime.

Active message exampleATT111 JAN01 16:02:01 6234 INFO ATT SIMULTANEOUS TESTS

RESET FROM 5 TO 10 SIZE

Clear message examplen/a

ATT111 487

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 488: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ATT112The Automatic Trunk Testing (ATT) subsystem report ATT112. Thesubsystem generates ATT112 when the system selects test equipment orreference trunks.

The trunk test starts after the system selects test equipment. The ATTsubsystem generates the ATT112 report after the system seizes and teststhe test equipment.

Some trunk tests require one or more reference trunks. The subsystemstarts the trunk test after the system selects the reference trunk. The ATTsubsystem generates the ATT112 report after the system seizes and teststhis reference trunk.

There is no additional information

Remedial actionn/a

AttributesAttribute Value

Severity Warning

Format1.ATT112 mmmdd hh:mm:ss ssdd INFO GRP cllinm

equtxt SELECTED: trkid typetxt

Selected field descriptionsField Value Fixed or

VariableDescription

INFO GRP cllinm customer data TableCLLI

Variable Provides common language locationidentifier (CLLI) of trunk group. ListCLLI from Cl MAP level for correctCLLI.

equtxt REFERENCE TRUNK Variable Indicates that the system selected thereference trunk.

TEST EQUIPMENT Variable Indicates that the system selected thetest equipment facilities.

TLPA REFERENCETRUNK

Variable Indicates the system selectedreference trunks for loop around trunktest.

488 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 489: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

SELECTED: trkid Symbolic text Variable Provides equipment identification forreference trunk, loop aroundreference-trunk, or test equipment.Refer to Table I.

typetxt TESTEQ Variable Indicates the system selected testequipment. Displayed if equtxt= TESTEQUIPMENT.

REFERENCE Variable Indicates the system selected thereference trunk. Appears if equtxt=REFERENCE TRUNK or TLPAREFERENCE TRUNK.

Active message example1.ATT112 DEC13 05:07:55 1126 INFO GRP OTMF1

TEST EQUIPMENT SELECTED: TTU 1 TESTEQ

Clear message examplen/a

Associated OM registers

ATT113The Automatic Trunk Testing (ATT) subsystem report ATT113. Thesubsystem generates ATT113 when a 105-type trunk test completes.There are seven different formats for ATT113. Each format has a differentExplanation Table for the fields that appear. The following are the tests foreach of the seven formats:

• FORMAT 1 TL6N, TL6S, T165, T5LB, and T56N

• FORMAT 2 TL05, TL0S, TL05, T105, T5AS, T5AT, and T50L

• FORMAT 3 TSBS and TS65

• FORMAT 4 TS05

• FORMAT 5 TSBT, T5BS, and T5SB

• FORMAT 6 TERL

• FORMAT 7 T5LH.

ATT113 489

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 490: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The trunk tests that ATT113 reports perform a part of the following tests:

• Two-way transmission loss measurement test that uses one of twotypes of test tones:

• A set of test tones at 404, 1004, and 2804 Hz, with a signal strength of-16 dBm

• A single test tone at 1004 Hz with a signal strength of 0 dBm.

• Far-end self-check of transmission test equipment, that uses the sametype of test tones as the transmission loss measurement test.

• Two-way noise measurement test, that uses a C-notched filter. Thistest runs while the system makes a 1004 Hz test tone is on the trunk.The C-notched filter attenuates only the test tone frequency to makesure of accurate noise measurements. The noise measurement testcan run with the transmission loss test. The transmission loss test usestest tones at 404, 1004, and 2804 Hz, and -16 dBm.

• Two-way noise measurement test that uses a C-message filter. The C-message filter is a bandpass filter over the voice frequency range. Thisnoise measurement test can occur along with the transmission losstest. The transmission loss test uses a test tone at 1004 Hz and 0 dBm.

• Far-end self-check of the noise test equipment, that uses the samefilter type that the two-way noise measurement tests use.

• Two-way return loss measurement and far-end self check for thefollowing tests:

• Echo Return Loss (ERL) test

• Low frequency Singing Return Loss (SRL) test

• High frequency Singing Return Loss (SHI) test.

Remedial actionIf rslttxt= PASS or there is no result, there is no action required.

If rslttxt = FAIL, see Card Replacement Procedures, for step-by-stepinstructions. Take immediate action if qltxt = Q2.

AttributesAttribute Value

Severity Warning

FormatATT113 mmmdd hh:mm:ss ssdd INFO

490 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 491: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

CKT trkid

tstnm MEAS AT-16 DB EML: nn.n DB qltxt rslttxt

LOSS MEAS AT:404 1004 2804 HZ

FE_S.C: sctxt sctxt sctxt

FN_DEV: n1 n2 n3 DB

NF_DEV: n1 n2 n3 DB

NOISE C_NOTCHED NML: nn NIAL: nn DBRN

FE_S.C: sctxt FN_NSE: nn.n NF_NSE: nn.n DBRN

RETURN LOSS ERL SRL SHI

F_N: n1 n2 n3 DB

N_F: n1 n2 n3

Selected field descriptionsField Value Fixed or

VariableDescription

INFO CKT Representative text Variable Exercises equipment identification forsuspect trunk equipment.

T5LH Constant Fixed Demonstrates 105-type test lineperformed singing return loss (low andhigh frequencies) measurement.

RETURN LOSS SRLSHI

Constant Fixed Cites table header for following returnloss transmission measurement tests:

• Low frequency singing return loss

• High frequency singing return loss

F_N: n1 n2 DB -99.9 to 99.9 dB Variable States the results of far-to-near endreturn loss test for SRL and SHI

N_F: n1 n2 n3 -99.9 to 99.9 dB Variable States results of far-to-near end returnloss test for SRL and SHI

Active message exampleATT113 JAN01 00:00:01 9098 INFO

CKT MTRLP2XX 34

ATT113 491

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 492: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

T56N MEAS AT -16 DB EML: 4.0 DB Q1 PASS

LOSS MEAS AT: 404 1004 2804 HZ

FN_DEV: 0.5 0.9 1.0 DB

NF_DEV: -0.5 0.5 -1.1 DB

NOISE C_NOTCHED NML: 30 NIAL: 50 DBRN

FN_NSE: 20 NF_NSE: 30 DBRN

RETURN LOSS ERL SRL SHI

F_N: 22.5 15.6 20.2 DB

N_F: 20.0 15.0 30.0 DB

Clear message examplen/a

Associated OM registers

ATT113 Format 2The Automatic Trunk Testing (ATT) subsystem report ATT113. Thesubsystem generates ATT113 when a 105-type trunk test completes.There are seven different formats for ATT113. Each format has a differentExplanation Table for the fields that appear. The following are the tests foreach of the seven formats:

• FORMAT 1 TL6N, TL6S, T165, T5LB, and T56N

• FORMAT 2 TL05, TL0S, TL05, T105, T5AS, T5AT, and T50L

• FORMAT 3 TSBS and TS65

• FORMAT 4 TS05

• FORMAT 5 TSBT, T5BS, and T5SB

• FORMAT 6 TERL

• FORMAT 7 T5LH.

492 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 493: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The trunk tests that ATT113 reports perform a part of the following tests:

• Two-way transmission loss measurement test that uses one of twotypes of test tones:

• A set of test tones at 404, 1004, and 2804 Hz, with a signal strength of-16 dBm

• A single test tone at 1004 Hz with a signal strength of 0 dBm.

• Far-end self-check of transmission test equipment, that uses the sametype of test tones as the transmission loss measurement test.

• Two-way noise measurement test, that uses a C-notched filter. Thistest runs while the system makes a 1004 Hz test tone is on the trunk.The C-notched filter attenuates only the test tone frequency to makesure of accurate noise measurements. The noise measurement testcan run with the transmission loss test. The transmission loss test usestest tones at 404, 1004, and 2804 Hz, and -16 dBm.

• Two-way noise measurement test that uses a C-message filter. The C-message filter is a bandpass filter over the voice frequency range. Thisnoise measurement test can occur along with the transmission losstest. The transmission loss test uses a test tone at 1004 Hz and 0 dBm.

• Far-end self-check of the noise test equipment, that uses the samefilter type that the two-way noise measurement tests use.

• Two-way return loss measurement and far-end self check for thefollowing tests:

• Echo Return Loss (ERL) test

• Low frequency Singing Return Loss (SRL) test

• High frequency Singing Return Loss (SHI) test.

Remedial actionIf rslttxt= PASS or there is no result, there is no action required.

If rslttxt = FAIL, see Card Replacement Procedures, for step-by-stepinstructions. Take immediate action if qltxt = Q2.

AttributesAttribute Value

Severity Warning

FormatATT113 mmmdd hh:mm:ss ssdd INFO

ATT113 Format 2 493

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 494: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

CKT trkid

tstnm LOSS MEAS AT 0 dB AND AT 1004 HZ EML: nn.n dB qltxt

FE_S.C: sctxt FN_DEV: nn.n NF_DEV: nn.n DB

NOISE C_MESSAGE NML: nn NIAL: nn DBRN

FE_S.C: sctxt FN_NSE: nn.n NF_NSE: nn.n DBRN

RETURN LOSS ERL SRL SHI

F_N: n1 n2 n3 DB

N_F: n1 n2 n3

Selected field descriptionsField Value Fixed or

VariableDescription

INFO CKT Representative text Variable Exercises equipment identification forsuspect trunk equipment.

T5LH Constant Fixed Demonstrates 105-type test lineperformed singing return loss (low andhigh frequencies) measurement.

RETURN LOSS SRLSHI

Constant Fixed Cites table header for following returnloss transmission measurement tests:

• Low frequency singing return loss

• High frequency singing return loss

F_N: n1 n2 DB -99.9 to 99.9 dB Variable States the results of far-to-near endreturn loss test for SRL and SHI

N_F: n1 n2 n3 -99.9 to 99.9 dB Variable States results of far-to-near end returnloss test for SRL and SHI

Active message exampleATT113 JAN01 00:00:02 9098 INFO

T5AS LOSS MEAS AT 0 dB AND AT 1004 HZ EML: 4.0 dB PASS

FE_S.C: OK FN_DEV: 0.1 NF_DEV: -0.2 DB

NOICE C_MESSAGE NML: 30 NIAL: 41 DBRN

FE_S.C: OK FN_NSE: 20 NF_NSE: 29 DBRN

494 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 495: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

RETURN LOSS ERL SRL SHI

F_N: 22.5 15.6 20.2 DB

N_F: 20.0 15.0 30.0 DB

Clear message examplen/a

Associated OM registers

ATT113 Format 3The Automatic Trunk Testing (ATT) subsystem report ATT113. Thesubsystem generates ATT113 when a 105-type trunk test completes.There are seven different formats for ATT113. Each format has a differentExplanation Table for the fields that appear. The following are the tests foreach of the seven formats:

• FORMAT 1 TL6N, TL6S, T165, T5LB, and T56N

• FORMAT 2 TL05, TL0S, TL05, T105, T5AS, T5AT, and T50L

• FORMAT 3 TSBS and TS65

• FORMAT 4 TS05

• FORMAT 5 TSBT, T5BS, and T5SB

• FORMAT 6 TERL

• FORMAT 7 T5LH.

The trunk tests that ATT113 reports perform a part of the following tests:

• Two-way transmission loss measurement test that uses one of twotypes of test tones:

• A set of test tones at 404, 1004, and 2804 Hz, with a signal strength of-16 dBm

• A single test tone at 1004 Hz with a signal strength of 0 dBm.

• Far-end self-check of transmission test equipment, that uses the sametype of test tones as the transmission loss measurement test.

• Two-way noise measurement test, that uses a C-notched filter. Thistest runs while the system makes a 1004 Hz test tone is on the trunk.The C-notched filter attenuates only the test tone frequency to makesure of accurate noise measurements. The noise measurement testcan run with the transmission loss test. The transmission loss test usestest tones at 404, 1004, and 2804 Hz, and -16 dBm.

ATT113 Format 3 495

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 496: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• Two-way noise measurement test that uses a C-message filter. The C-message filter is a bandpass filter over the voice frequency range. Thisnoise measurement test can occur along with the transmission losstest. The transmission loss test uses a test tone at 1004 Hz and 0 dBm.

• Far-end self-check of the noise test equipment, that uses the samefilter type that the two-way noise measurement tests use.

• Two-way return loss measurement and far-end self check for thefollowing tests:

• Echo Return Loss (ERL) test

• Low frequency Singing Return Loss (SRL) test

• High frequency Singing Return Loss (SHI) test.

Remedial actionIf rslttxt= PASS or there is no result, there is no action required.

If rslttxt = FAIL, see Card Replacement Procedures, for step-by-stepinstructions. Take immediate action if qltxt = Q2.

AttributesAttribute Value

Severity Warning

FormatATT113 mmmdd hh:mm:ss ssdd INFO

CKT trkid

tstnm SELFCHECK AT-16 DB AND AT: 404 1004 2804 Hz

LOSS FE_S.C: sctxt sctxt sctxt

NOISE C_NOTCHED FE_S.C: sctxt

RETURN LOSS ERL SRL SHI

FE_S.C: sctxt sctxt sctxt

496 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 497: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

T5LH Constant Fixed Demonstrates 105-type test lineperformed singing return loss (low andhigh frequencies) measurement.

RETURN LOSS SRLSHI

Constant Fixed Cites table header for following returnloss transmission measurement tests:

• Low frequency singing return loss

• High frequency singing return loss

F_N: n1 n2 DB -99.9 to 99.9 dB Variable States the results of far-to-near endreturn loss test for SRL and SHI

N_F: n1 n2 n3 -99.9 to 99.9 dB Variable States results of far-to-near end returnloss test for SRL and SHI

INFO CKT Representative text Variable Exercises equipment identification forsuspect trunk equipment.

Active message exampleATT113 JAN01 00:01:01 1001 INFO

CKT MTXTRB2XX 36

TS65 SELFCHECK AT -16 DB AND AT: 404 1004 2804 Hz

LOSS FE_S.C: OK OK OK

NOISE C_NOTCHED FE_S.C: OK

Clear message examplen/a

Associated OM registers

ATT113 Format 4The Automatic Trunk Testing (ATT) subsystem report ATT113. Thesubsystem generates ATT113 when a 105-type trunk test completes.There are seven different formats for ATT113. Each format has a differentExplanation Table for the fields that appear. The following are the tests foreach of the seven formats:

• FORMAT 1 TL6N, TL6S, T165, T5LB, and T56N

• FORMAT 2 TL05, TL0S, TL05, T105, T5AS, T5AT, and T50L

• FORMAT 3 TSBS and TS65

ATT113 Format 4 497

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 498: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• FORMAT 4 TS05

• FORMAT 5 TSBT, T5BS, and T5SB

• FORMAT 6 TERL

• FORMAT 7 T5LH.

The trunk tests that ATT113 reports perform a part of the following tests:

• Two-way transmission loss measurement test that uses one of twotypes of test tones:

• A set of test tones at 404, 1004, and 2804 Hz, with a signal strength of-16 dBm

• A single test tone at 1004 Hz with a signal strength of 0 dBm.

• Far-end self-check of transmission test equipment, that uses the sametype of test tones as the transmission loss measurement test.

• Two-way noise measurement test, that uses a C-notched filter. Thistest runs while the system makes a 1004 Hz test tone is on the trunk.The C-notched filter attenuates only the test tone frequency to makesure of accurate noise measurements. The noise measurement testcan run with the transmission loss test. The transmission loss test usestest tones at 404, 1004, and 2804 Hz, and -16 dBm.

• Two-way noise measurement test that uses a C-message filter. The C-message filter is a bandpass filter over the voice frequency range. Thisnoise measurement test can occur along with the transmission losstest. The transmission loss test uses a test tone at 1004 Hz and 0 dBm.

• Far-end self-check of the noise test equipment, that uses the samefilter type that the two-way noise measurement tests use.

• Two-way return loss measurement and far-end self check for thefollowing tests:

• Echo Return Loss (ERL) test

• Low frequency Singing Return Loss (SRL) test

• High frequency Singing Return Loss (SHI) test.

Remedial actionIf rslttxt= PASS or there is no result, there is no action required.

If rslttxt = FAIL, see Card Replacement Procedures, for step-by-stepinstructions. Take immediate action if qltxt = Q2.

498 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 499: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

Format.ATT113 mmmdd hh:mm:ss ssdd INFO

CKT trkid

tstnm LOSS AT 0 DB 1004 HZ FE_S.C: sctxt

NOISE C_MESSAGE FE_S.C: sctxt

Selected field descriptionsField Value Fixed or

VariableDescription

INFO CKT Representative text Variable Exercises equipment identification forsuspect trunk equipment.

T5LH Constant Fixed Demonstrates 105-type test lineperformed singing return loss (low andhigh frequencies) measurement.

RETURN LOSS SRLSHI

Constant Fixed Cites table header for following returnloss transmission measurement tests:

• Low frequency singing return loss

• High frequency singing return loss

F_N: n1 n2 DB -99.9 to 99.9 dB Variable States the results of far-to-near endreturn loss test for SRL and SHI

N_F: n1 n2 n3 -99.9 to 99.9 dB Variable States results of far-to-near end returnloss test for SRL and SHI

Active message exampleATT113 JAN01 00:01:01 1001 INFO

CKT MTXTRB2XX 36

TS05 LOSS AT 0 DB 1004 HZ FE_S.C: OK

NOISE C_MESSAGE FE_S.C: OK

Clear message examplen/a

ATT113 Format 4 499

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 500: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ATT113 Format 5The Automatic Trunk Testing (ATT) subsystem report ATT113. Thesubsystem generates ATT113 when a 105-type trunk test completes.There are seven different formats for ATT113. Each format has a differentExplanation Table for the fields that appear. The following are the tests foreach of the seven formats:

• FORMAT 1 TL6N, TL6S, T165, T5LB, and T56N

• FORMAT 2 TL05, TL0S, TL05, T105, T5AS, T5AT, and T50L

• FORMAT 3 TSBS and TS65

• FORMAT 4 TS05

• FORMAT 5 TSBT, T5BS, and T5SB

• FORMAT 6 TERL

• FORMAT 7 T5LH.

The trunk tests that ATT113 reports perform a part of the following tests:

• Two-way transmission loss measurement test that uses one of twotypes of test tones:

• A set of test tones at 404, 1004, and 2804 Hz, with a signal strength of-16 dBm

• A single test tone at 1004 Hz with a signal strength of 0 dBm.

• Far-end self-check of transmission test equipment, that uses the sametype of test tones as the transmission loss measurement test.

• Two-way noise measurement test, that uses a C-notched filter. Thistest runs while the system makes a 1004 Hz test tone is on the trunk.The C-notched filter attenuates only the test tone frequency to makesure of accurate noise measurements. The noise measurement testcan run with the transmission loss test. The transmission loss test usestest tones at 404, 1004, and 2804 Hz, and -16 dBm.

• Two-way noise measurement test that uses a C-message filter. The C-message filter is a bandpass filter over the voice frequency range. Thisnoise measurement test can occur along with the transmission losstest. The transmission loss test uses a test tone at 1004 Hz and 0 dBm.

• Far-end self-check of the noise test equipment, that uses the samefilter type that the two-way noise measurement tests use.

• Two-way return loss measurement and far-end self check for thefollowing tests:

500 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 501: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• Echo Return Loss (ERL) test

• Low frequency Singing Return Loss (SRL) test

• High frequency Singing Return Loss (SHI) test.

Remedial actionIf rslttxt= PASS or there is no result, there is no action required.

If rslttxt = FAIL, see Card Replacement Procedures, for step-by-stepinstructions. Take immediate action if qltxt = Q2.

AttributesAttribute Value

Severity Warning

FormatATT113 mmmdd hh:mm:ss ssdd INFO

CKT trkid

tstnm RETURN LOSS ERL SRL SHI qltxt rslttxt

FE_S.C: sctxt sctxt sctxt

F_N: n1 n2 n3 DB

N_F: n1 n2 n3 DB

Selected field descriptionsField Value Fixed or

VariableDescription

T5LH Constant Fixed Demonstrates 105-type test lineperformed singing return loss (low andhigh frequencies) measurement.

RETURN LOSS SRLSHI

Constant Fixed Cites table header for following returnloss transmission measurement tests:

• Low frequency singing return loss

• High frequency singing return loss

F_N: n1 n2 DB -99.9 to 99.9 dB Variable States the results of far-to-near endreturn loss test for SRL and SHI

ATT113 Format 5 501

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 502: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

N_F: n1 n2 n3 -99.9 to 99.9 dB Variable States results of far-to-near end returnloss test for SRL and SHI

INFO CKT Representative text Variable Exercises equipment identification forsuspect trunk equipment.

Active message exampleATT113 JAN01 00:01:011234 INFO

CKT MTXTDN2FF 45

T5BS RETURN LOSS ERL SRL SHI PASS

FE_S.C: OK OK OK

F_N: 20.5 15.4 20.4 DB

N_F: 20.4 16.0 21.0 DB

Clear message examplen/a

Associated OM registers

ATT113 Format 6The Automatic Trunk Testing (ATT) subsystem report ATT113. Thesubsystem generates ATT113 when a 105-type trunk test completes.There are seven different formats for ATT113. Each format has a differentExplanation Table for the fields that appear. The following are the tests foreach of the seven formats:

• FORMAT 1 TL6N, TL6S, T165, T5LB, and T56N

• FORMAT 2 TL05, TL0S, TL05, T105, T5AS, T5AT, and T50L

• FORMAT 3 TSBS and TS65

• FORMAT 4 TS05

• FORMAT 5 TSBT, T5BS, and T5SB

• FORMAT 6 TERL

• FORMAT 7 T5LH.

502 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 503: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The trunk tests that ATT113 reports perform a part of the following tests:

• Two-way transmission loss measurement test that uses one of twotypes of test tones:

• A set of test tones at 404, 1004, and 2804 Hz, with a signal strength of-16 dBm

• A single test tone at 1004 Hz with a signal strength of 0 dBm.

• Far-end self-check of transmission test equipment, that uses the sametype of test tones as the transmission loss measurement test.

• Two-way noise measurement test, that uses a C-notched filter. Thistest runs while the system makes a 1004 Hz test tone is on the trunk.The C-notched filter attenuates only the test tone frequency to makesure of accurate noise measurements. The noise measurement testcan run with the transmission loss test. The transmission loss test usestest tones at 404, 1004, and 2804 Hz, and -16 dBm.

• Two-way noise measurement test that uses a C-message filter. The C-message filter is a bandpass filter over the voice frequency range. Thisnoise measurement test can occur along with the transmission losstest. The transmission loss test uses a test tone at 1004 Hz and 0 dBm.

• Far-end self-check of the noise test equipment, that uses the samefilter type that the two-way noise measurement tests use.

• Two-way return loss measurement and far-end self check for thefollowing tests:

• Echo Return Loss (ERL) test

• Low frequency Singing Return Loss (SRL) test

• High frequency Singing Return Loss (SHI) test.

Remedial actionIf rslttxt= PASS or there is no result, there is no action required.

If rslttxt = FAIL, see Card Replacement Procedures, for step-by-stepinstructions. Take immediate action if qltxt = Q2.

AttributesAttribute Value

Severity Warning

FormatATT113 mmmdd hh:mm:ss ssdd INFO qltxt rslttxt

ATT113 Format 6 503

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 504: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

CKT trkid

TERL RETURN LOSS ERL

F_N: nn.n DB

N_F: nn.n DB

Selected field descriptionsField Value Fixed or

VariableDescription

INFO CKT Representative text Variable Exercises equipment identification forsuspect trunk equipment.

T5LH Constant Fixed Demonstrates 105-type test lineperformed singing return loss (low andhigh frequencies) measurement.

RETURN LOSS SRLSHI

Constant Fixed Cites table header for following returnloss transmission measurement tests:

• Low frequency singing return loss

• High frequency singing return loss

F_N: n1 n2 DB -99.9 to 99.9 dB Variable States the results of far-to-near endreturn loss test for SRL and SHI

N_F: n1 n2 n3 -99.9 to 99.9 dB Variable States results of far-to-near end returnloss test for SRL and SHI

Active message exampleATT113 JAN01 00:01:011234 INFO

CKT MTXTDN2FF 45

TERL RETURN LOSS ERL PASS

F_N: 20.5 DB

N_F: 20.4 DB

Clear message examplen/a

504 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 505: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ATT113 Format 7The Automatic Trunk Testing (ATT) subsystem report ATT113. Thesubsystem generates ATT113 when a 105-type trunk test completes.There are seven different formats for ATT113. Each format has a differentExplanation Table for the fields that appear. The following are the tests foreach of the seven formats:

• FORMAT 1 TL6N, TL6S, T165, T5LB, and T56N

• FORMAT 2 TL05, TL0S, TL05, T105, T5AS, T5AT, and T50L

• FORMAT 3 TSBS and TS65

• FORMAT 4 TS05

• FORMAT 5 TSBT, T5BS, and T5SB

• FORMAT 6 TERL

• FORMAT 7 T5LH.

The trunk tests that ATT113 reports perform a part of the following tests:

• Two-way transmission loss measurement test that uses one of twotypes of test tones:

• A set of test tones at 404, 1004, and 2804 Hz, with a signal strength of-16 dBm

• A single test tone at 1004 Hz with a signal strength of 0 dBm.

• Far-end self-check of transmission test equipment, that uses the sametype of test tones as the transmission loss measurement test.

• Two-way noise measurement test, that uses a C-notched filter. Thistest runs while the system makes a 1004 Hz test tone is on the trunk.The C-notched filter attenuates only the test tone frequency to makesure of accurate noise measurements. The noise measurement testcan run with the transmission loss test. The transmission loss test usestest tones at 404, 1004, and 2804 Hz, and -16 dBm.

• Two-way noise measurement test that uses a C-message filter. The C-message filter is a bandpass filter over the voice frequency range. Thisnoise measurement test can occur along with the transmission losstest. The transmission loss test uses a test tone at 1004 Hz and 0 dBm.

• Far-end self-check of the noise test equipment, that uses the samefilter type that the two-way noise measurement tests use.

• Two-way return loss measurement and far-end self check for thefollowing tests:

ATT113 Format 7 505

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 506: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• Echo Return Loss (ERL) test

• Low frequency Singing Return Loss (SRL) test

• High frequency Singing Return Loss (SHI) test.

Remedial actionIf rslttxt= PASS or there is no result, there is no action required.

If rslttxt = FAIL, see Card Replacement Procedures, for step-by-stepinstructions. Take immediate action if qltxt = Q2.

AttributesAttribute Value

Severity Warning

FormatATT113 mmmdd hh:mm:ss ssdd INFO qltxt rslttxt

CKT trkid

TERL RETURN LOSS SRL SHI

F_N: n1 n2 DB

N_F: n1 n2 DB

Selected field descriptionsField Value Fixed or

VariableDescription

INFO CKT Representative text Variable Exercises equipment identification forsuspect trunk equipment.

T5LH Constant Fixed Demonstrates 105-type test lineperformed singing return loss (low andhigh frequencies) measurement.

RETURN LOSS SRLSHI

Constant Fixed Cites table header for following returnloss transmission measurement tests:

• Low frequency singing return loss

• High frequency singing return loss

F_N: n1 n2 DB -99.9 to 99.9 dB Variable States the results of far-to-near endreturn loss test for SRL and SHI

N_F: n1 n2 n3 -99.9 to 99.9 dB Variable States results of far-to-near end returnloss test for SRL and SHI

506 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 507: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleATT113 JAN01 00:01:011234 INFO

CKT MTXTDN2FF 45

T5LH RETURN LOSS SRL SHI PASS

F_N: 15.4 20.4 DB

N_F: 16.0 21.0 DB

Clear message examplen/a

Associated OM registers

ATT114The Automatic Trunk Testing (ATT) subsystem generates ATT114 if thesystem detects a fault. The system detects a fault when the system runs atrunk test on a 105-type test line. Log report ATT114 identifies the test andfault. A C-message filter is a bandpass filter over the voice frequencyrange. Noise measurements use a C-notched filter when a test tone is onthe trunk. The C-notched filter attenuates the test tone frequency to makesure noise measurements are accurate. A command at the ATT MAP levelor a scheduled test can initiate these tests.

Remedial actionIf action in description field fails to correct the problem, contact next level ofmaintenance.

AttributesAttribute Value

Severity Warning

FormatATT114 mmmdd hh:mm:ss ssdd INFO

CKT trkid

tstnm FAULT: flttxt

ATT114 507

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 508: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

FAR ENDDISCONNECTED

Variable Indicates far-end office disconnectedwithout a warning after logon.

ACTION: Try test again.

HI-DRY TONEDETECTED

Variable Indicates far-end office did not sendan off-hook signal after a burst ofaudible ringing tone.

ACTION: Diagnose trunk under test. Ifdiagnostics pass, trouble is in far-endoffice or transmission equipment.Diagnose transmission equipment.

HIGH TONEDETECTED

Variable Indicates far-end office detected ahigh tone.

ACTION: Try test again.

INVALID TNE DETFAR END

Variable Indicates far-end office detected aninvalid tone.

ACTION: Check test and trunkparameters and options again. Trytest again.

INVALID TNE DETNEAR END

Variable Indicates DMS switch detected aninvalid tone from far-end office.

ACTION: Try test again.

INVALID TST REQFAR END

Variable Indicates far-end office returned aninvalid test request signal.

ACTION: Recheck test and trunkparameters and options. Try testagain.

MAILBOX FAULT Variable Indicates the system encounterssoftware trouble that affects mailbox.

ACTION: Try test again.

MILLIWATT TONEDETECTED

Variable Indicates far-end office returned amilliwatt tone.

ACTION: Try test again.

NO ANSWER FROMFAR END

Variable Indicates far-end office failed torespond after system seized trunk.

508 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 509: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Try test again.

NO FAR END TESTEQUIP

Variable Indicates far-end office does not havethe necessary test equipment.

ACTION: Check trunk and testparameters and options.

NO Q LIMITSRECEIVED

Variable Indicates system did not receivemaintenance action and immediateaction limits for transmissionmeasurements.

ACTION: Diagnose transmission testequipment. Try test again.

NO REPLY FROMFAR END

Variable Indicates that far-end office did notreply to test request signal.

ACTION: Try test again.

NO TESTEQUIPMENT

Variable Indicates test line test failed becausetest equipment is not available.

ACTION: Check trunk and diagnostictest parameters and options.

NO TL/NO FAR ENDTEST EQPMT

Variable Indicates test line or far-end office testequipment is not available, generallybecause of a data error.

ACTION: Check trunk and testparameters and options. If data erroris not found, the fault is at far-endoffice.

NO TNE DET FAREND

Variable Indicates far-end office failed to detecta test tone.

ACTION: Diagnose trunk andtransmission test equipment. Try testagain.

NO TNE DET NEAREND

Variable Indicates DMS switch failed to detecta test tone from far-end office.

ACTION: Try test again.

OUTPULSING -INVALID REPLY

Variable Indicates the system encounterstransmission problems because of aninvalid reply from far-end office.

ATT114 509

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 510: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Diagnose trunk under test. Ifdiagnostics pass, problem is in far-endoffice or transmission equipment.Diagnose transmission equipment.

OUTPULSING -CONGESTION

Variable Indicates the system encounterstransmission trouble because of near-end congestion.

ACTION: Diagnose trunk under test. Ifdiagnostics pass, the trouble is in far-end office or transmission equipment.Diagnose transmission equipment.

OUTPULSING -HARDWARE TBL

Variable Indicates system encounterstransmission trouble because of ahardware fault.

ACTION: Diagnose trunk under test. Ifdiagnostics pass, problem is in the far-end office or transmission equipment.Diagnose transmission equipment.

OUTPULSING - NOREPLY

Variable Notes the system encounterstransmission trouble because the far-end office did not reply.

ACTION: Diagnose trunk under test. Ifdiagnostics pass, trouble is in far-endoffice or transmission equipment.Diagnose transmission equipment.

OUTPULSING -TROUBLE

Variable Indicates the system encounterstransmission trouble.

ACTION: Diagnose trunk under test. Ifdiagnostics pass, problem is in far-endoffice or transmission equipment.Diagnose transmission equipment.

OVERFLOW TONEDETECTED

Variable Indicates far-end office returned anoverflow tone.

ACTION: Try test again.

PERIODIC SIGNALTONE DETECTED

Variable Indicates far-end office returns aperiodic tone.

ACTION: Try test again.

510 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 511: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

QUIETTERMINATION

Variable Indicates far-end office applies quiettermination to trunk.

ACTION: Try test again.

REORDER TONEDETECTED

Variable Indicates far-end office returns areorder tone.

ACTION: Try test again.

RINGING TONEDETECTED

Variable Indicates far-end office returns ringingtone.

ACTION: Try test again.

SELF -CHECKFAILURE

Variable Indicates trunk or test equipment failself-check.

ACTION: Diagnose trunk and testequipment.

TERM TESTEQUIPMENT FL

Variable Indicates test did not terminatenormally because of a test equipmentfailure.

ACTION: Diagnose test equipment.Try test again.

TEST EQPMT NOTREQUIRED

Variable Indicates test failed because of aproblem in requested test. Therequested test called for equipmentthat was not necessary.

ACTION: Check test and trunkparameters and options. Try testagain.

TEST EQUIPMENTFAULT

Variable Indicates failure of TTT activity toopen or reset.

ACTION: Diagnose TTT facility. Trytest again.

TEST REQUESTFAILURE

Variable Indicates the ATT subsystem does notstart requested test.

ACTION: Try test again.

TONE DETECTORFAULT

Variable Indicates failure of tone detectionsystem.

ATT114 511

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 512: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Diagnose tone detectioncircuit. Try test again.

TPT IS NOTRECEIVED

Variable Indicates far-end office did not receivetest progress tone (TPT) whenexpected.

ACTION: Try test again.

TPT TONEDETECTED

Variable Indicates far-end office received TPT,but did not expect to receive TPT.

ACTION: Try test again.

FAULT UNKNOWN TONEDETECTED

Variable Indicates far-end office returned anunknown tone.

ACTION: Try test again.

120 IPM TONEDETECTED

Variable Indicates far-end office returned toneat 120 impulses for each minute.

ACTION: Try test again.

30 IPM TONEDETECTED

Variable Indicates far-end office returned toneat 30 impulses for each minute.

ACTION: Try test again.

INFO CKT ConstantRepresentative text

Variable Indicates the system generates theinformation log. Provides equipmentidentification for suspect trunkequipment.

tstnm TERL Variable Indicates the system uses 105-typetest line to perform echo return lossmeasurement.

TL0N Variable Indicates the system uses 105-typetest line to perform loss (1004 Hz at 0dBm) and noise (C-message filter)tests.

TL0S Variable Indicates the system uses a 105-typetest line to perform loss (1004 Hz at 0dBm) test with self-check.

TL05 Variable Notes the system uses a 105-type testline to perform loss (1004 Hz at 0dBm) test.

TL6N Variable Indicates the system uses a 105-typetest line to perform tests. The systemperforms loss (404, 1004 and 2804 Hz

512 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 513: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

at -16 dBm). The system uses a 105-type test line to perform noise (C-notched filter) test.

TL6S Variable Indicates the system uses a 105-typetest line to perform loss (404, 1004and 2804 Hz at -16 dBm) test withself-check.

TL65 Variable Indicates the system uses a 105-typetest line to perform loss (404, 1004and 2804 Hz at -16 dBm) test.

TSBS Variable Indicates the system uses a 105-typetest line to perform far-end equipmentself-check of:

• loss (404, 1004, and 2804 Hz testtone at -16 dBm) test

• noise (C-notched filter) test

• return loss test

TS05 Variable Indicates the system uses a 105-typetest line to perform far-end equipmentself-check. The system checks loss(1004 Hz 0 dBm) and noise (C-message filter).

TS65 Variable Indicates the system uses a 105-typetest line to perform far-end equipmentself-check. The system checks loss(404, 1004 and 2804 Hz test tone at-16 dBm) and noise (C-notched filter).

T105 Variable Indicates the system uses a 105-typetest line to perform tests. The systemperforms loss (1004 Hz at 0 dBm) andnoise (C-message filter) test with self-check.

T165 Variable Indicates the system used 105-typetest line to perform tests. The systemperforms loss (404, 1004 and 2804 Hzat -16 dBm) and noise (C-notchedfilter) test with self-check.

T5AS Variable Indicates the system used 105-typetest line to perform tests with self-check. The system performs loss(1004 Hz at 0 dBm), noise (C-message filter) and return loss test.

ATT114 513

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 514: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

T5AT Variable Indicates the system used 105-typetest line to perform tests. The systemperforms loss (C1004 Hz at 0 dBm),noise (C-message filter) and returnloss (C1004 Hz at 0 dB) test.

T5BS Variable Indicates the system uses 105-typetest line to perform return lossmeasurement and self-check test.

T5BT Variable Indicates the system uses 105-typetest line to perform return lossmeasurement.

T5LB Variable Indicates the system uses 105-typetest line to perform loss (404, 1004and 2804 Hz at -16 dBm) and returnloss test.

T5LH Variable Indicates the system uses 105-typetest line to perform singing return loss(low and high frequencies)measurement.

T5SB Variable Indicates the system uses 105-typetest line to perform return loss testwith self-check.

T50L Variable Indicates the system uses 105-typetest line to perform tests. The systemperforms loss (1004 Hz at 0 dBm) andreturn loss (C1004 Hz at 0 dB) tests.

T56N Variable Indicates the system used 105-typetest line to perform tests. The systempreforms loss (404, 1004 and 2804 Hzat -16 dBm), noise (C-notched filter)and return loss tests.

FAULT ANNOUNCEMENTTONE DETECTED

Variable Indicates far-end office returnsrecorded announcement.

ACTION: Try test again.

BUSY TONEDETECTED

Variable Indicates far-end office returns busysignal

ACTION: Try test again.

CONNECTION FL -CONFUSION

Variable Indicates system encounters aconnection integrity fault.Transmission trunk testing (TTT)

514 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 515: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

facility failed to make a connection totrunk through network because ofsoftware trouble.

ACTION: Try test again.

CONNECTION FL -INTEGRITY

Variable Indicates system encounters aconnection integrity fault. The TTTfacility failed to make a connection totrunk through network because of achannel integrity loss.

ACTION: Diagnose transmission trunktesting equipment.

DIAL TONEDETECTED

Variable Indicates far-end office returned a dialtone.

ACTION: Try test again.

FAILED TO GETMAILBOX

Variable Indicates encounter of softwareproblem and loss of mailbox messageat receiving end.

ACTION: Try test again.

FAILED TO OPENTTU

Variable Indicates transmission test unit (TTU)failed to open when requested.

ACTION: Diagnose TTU.

FAILED TO SENDMESSAGE

Variable Indicates system encounters asoftware problem and loss of mailboxmessage at sending end.

ACTION: Try test again.

FAILED TO SET TTU Variable Indicates TTU failed to set or reset atrequest.

ACTION: Diagnose TTU.

FAILED TO STARTTTU

Variable Indicates TTU failed to start onrequest.

ACTION: Diagnose TTU.

FAR ENDCONGESTION

Variable Indicates system received congestionmessage from far-end office duringtest.

ATT114 515

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 516: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION: Far-end office does notalways have terminating test line.Check trunk parameters or options.

Active message exampleATT114 APR29 12:12:12 7394 INFO

MTRLPQXXX34 34

T105 FAULT: NO ANSWER FROM FAR END

Clear message examplen/a

Associated OM registers

ATT115The Automatic Trunk Testing (ATT) subsystem generates ATT115 when asuccessful ARTER transmission test runs. The ARTER test is theautomatic transmission test that the telephone network in Turkey uses.This test works with a 6805 or an equal system. The test design is not foruse in the North American market.

The 6805 can be a two-wire or four-wire unit. If the 6805 is a four-wire unit,the system executes the following trunk runs:

• Far-to-near end loss and noise test

• Near-to-far end loss and noise test

• Loop-around loss and noise test

If the 6805 is a two-wire unit, the system executes the far-to-near end lossand noise tests.

The system uses an 804Hz test tone at 0 dBm to perform transmissionloss measurements. In order to perform noise measurements, the 6805unit provides quiet termination to the trunk. The DMS switch measures thenoise levels.

Remedial actionn/a

516 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 517: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

Format1.ATT115 mmmdd hh:mm:ss ssdd INFO

CKT trkid

EML = nn.n DB NML = nn DBRN NIAL = nn DBRN

FN_DEV = nn.n ?!txt FN_NOISE = nn.n rtxt qltxt

NF_DEV = nn.n ?!txt NF_NOISE = nn.n rtxt qltxt

ANS RCVD = anstxt

Selected field descriptionsField Value Fixed or

VariableDescription

NIAL 1 to 63 Variable Indicates noise immediate action limit(NIAL) in decibels above referencenoise field. Field NIAL is an enteredvalue in customer data TableCLLIMTCE.DIAGDATA. If the noisemeasurement exceeds NIAL, initiatemaintenance action

FN_DEV -99.9 to +99.9 dB Variable Indicates far-or-near end lossdeviation in decibels field. FieldFN_DEV indicates difference betweenmeasured loss on trunk and EML indecibels.

NF_DEV -99.9 to +99.9 dB Variable Indicates near-to-far end lossdeviation in decibels field. FieldNF_DEV indicates difference betweenmeasured loss on trunk and EML indecibels. The system displays thisfield only for 6805 4-wire units.

?!txt Blank Variable Indicates loss deviation is less thanmaintenance limit

? Variable Indicates loss deviation is greater thanmaintenance limit and less thanimmediate action limit

! Variable Indicates loss deviation is greater thanimmediate action limit

ATT115 517

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 518: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

FN_NSE -99.9 to 99.9 Variable Indicates measured far-to-near endnoise in decibels above referencenoise

NF_NSE -99.9 to 99.9 Variable Indicates measured near-to-far endnoise in decibels above referencenoise. The system displays this fieldonly for 6805 4-wire units.

rtxt PASS Variable Indicates test passed. Loss and noisemeasurements in acceptable limits.

FAIL Variable Indicates test failed. Loss and noisemeasurements not in acceptablelimits.

qltxt Variable Blank Indicates transmissionmeasurements in acceptable limits

Q1 Variable Indicates transmission measurementsin maintenance limit. Initiatemaintenance action.

Q2 Variable Indicates transmission measurementsexceeded immediate action limit.Initiate immediate action.

ANS RECD Y Variable Indicates 6805 unit responded to trunktest request for digits

N Variable Indicates 6805 unit did not respond totrunk test request for digits

INFO CKT Representative text Variable Provides equipment identification forsuspect trunk equipment

TART Constant Fixed Indicates performance of ARTERtransmission test for system in Turkey

EML 0.0 to 36.0 Variable Indicates expected measured loss(EML) in decibels field. Field EML isan entered value in customer dataTable CLLIMTCE.DIAGDATA.

NML 1 to 63 Variable Provides noise maintenance limit(NML) in decibels above referencenoise field. Filed NML is an enteredvalue in customer data TableCLLIMTCE.DIAGDATA. If the noisemeasurement exceeds NML, initiatemaintenance action.

Active message example1.ATT115 FEB17 00:02:40 8831 INFO

518 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 519: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

CKT OTMF1 0

EML = 6.0 DB NML = 30 DBRN NIAL = 30 DBRN

FN_DEV = 1.1 FN_NOISE = 16 PASS

NF_DEV = 3.9 ? NF_NOISE = 16 PASS Q1

ANS RCVD = Y

Clear message examplen/a

Associated OM registers

ATT116The Automatic Trunk Testing (ATT) subsystem generates ATT116 when acellular trunk test terminates normally. Log report ATT116 reports threetypes of tests:

• The wire loop test measures loss and noise on wire trunk facilitiesbetween the DMS and cellular remote carrier unit (RCU).

• The audio loop test measures loss and noise on wire trunk facilities andRCU audio circuitry.

• The radio frequency loop test measures loss and noise on wire trunkfacilities, RCU audio, and radio frequency (RF) circuitry. The RCU RFcircuitry is the cellular transmitter. This test requires a test and alarmunit (TAU) that is remote from the RCU. A TAU is a remote cellulartelephone with circuitry to test, measure, and report on thetransmission characteristics of the RCU.

All loss measurements use a test tone of 1004 Hz at 0 dBM or -16 dBm. Allnoise measurements use a C-message filter or a C-notched filter.

A C-message filter is a bandpass filter over the voice frequency range.Noise measurements use a C-notched filter to take measurements while atest tone occurs. This filter attenuates the frequency of the test tone tomake accurate noise measurements.

Remedial actionIf rsltxt= PASS, there is no action required.

If rsltxt = FAIL, refer to Card Replacement Procedures for step-by-stepprocedures. If q1txt = Q2, take immediate action.

ATT116 519

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 520: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

Format1.ATT116 mmmdd hh:mm:ss ssdd INFO

CKT trkid

tstnm EML: nn.n FN_DEV: nn.n NF_DEV: nn.n qltxtt rslttxt

NML: nn NIAL: nn NOISE: nn.n

Selected field descriptionsField Value Fixed or

VariableDescription

INFO CKT Symbolic text Variable Provides equipment identification forsuspect trunk equipment

tstnm MXAM Variable Indicates performance of mobiletelephone exchange (MTX) audio looptest with C-message filter

MXAN Variable Indicates performance of MTX audioloop test with C-notch filter

MXRM Variable Indicates performance of MTX radiofrequency loop test with C-messagefilter

MXRN Variable Indicates performance of MTX radiofrequency loop test with C-notch filter

MXWM Variable Indicates performance of MTX wireloop test with C-message filter

MXWN Variable Indicates performance of MTX wireloop test with C-notch filter

EML 0.0 to 36.0 Variable Provides expected measured loss(EML) in decibels. Field EML is anentered value in customer data TableCLLIMTCE.DIAGDATA.

FN_DEV -99.9 to +99.9 Variable Provides far-to-near end deviation indecibels. Field FN_DEV indicatesdifference between measured loss ontrunk and EML in decibels.

FN_DEV *** Variable Indicates far-to-near end deviationexceeds 99.9 dB

520 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 521: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

NF_DEV -99.9 to +99.9 Variable Provides near-to-far end deviation.Field NF_DEV indicates differencebetween measured loss on trunk andEML in decibels.

*** Variable Indicates near-to-far end deviationexceeds 99.9 dB

rsltxt PASS Variable Indicates test passed. Noise and lossmeasurements in acceptable limits.

FAIL Variable Indicates failure of test. Noise andloss measurements not in acceptablelimits. Refer to Action section of thislog.

NML 1 to 63 Variable Indicates noise maintenance limit(NML) in decibels. Field NML is anentered value in customer data TableCLLIMTCE.DIAGDATA. If the NOISEmeasurement exceeds NML, initiatemaintenance action.

NIAL 1 to 63 Variable Indicates noise immediate action limit(NIAL) in decibels. NIAL is an enteredvalue in customer data TableCLLIMTCE.DIAGDATA. If noisemeasurement exceeds NIAL, initiateimmediate maintenance action.

NOISE -99.9 to +99.9 Variable Indicates far-to-near end noisemeasured on trunk in decibels abovereference noise (dBRN)

qltxt Blank Variable Indicates transmission measurementsin acceptable limits

Q1 Variable Indicates transmission measurementsin maintenance limit. Initiatemaintenance action.

Q2 Variable Indicates transmission measurementsexceed immediate action limit. Trunkrequires immediate action.

Active message example1.ATT116 NOV15 10:01:09 8200 INFO

CKT MONTANAACE 1

MXWM EML: 10.1 FN_DEV: -0.3 NF_DEV: 0.3 PASS

ATT116 521

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 522: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

NML: 30 NIAL: 50 NOISE: 21

Clear message examplen/a

Associated OM registers

ATT117The Automatic Trunk Testing (ATT) subsystem generates ATT117 when acellular mobile test call attempt occurs. The test call can be:

• from a test and alarm unit (TAU) to the mobile telephone exchangeremote carrier unit (MTX RCU).

• from the MTX RCU to the TAU.

If the test call completes, the test passes. If the test fails, the systemgenerates other log reports to explain the failure.

A command entered at the ATT MAP level or a scheduled test initiates thistest.

Remedial actionIf rsltxtx=PASS, there is no action required.

If rslttxt=FAIL, see other CELL or TRK log reports that the systemgenerated at the same time for problem isolation and solving.

AttributesAttribute Value

Severity Warning

Format1.ATT117 mmmdd hh:mm:ss ssdd INFO

CKT trkid

tstnm infotxt rslttxt

522 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 523: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFO Constant Fixed Indicates data that follows provides areport when a cellular mobile test callattempt occurs

CKT Symbolic text Variable Indicates equipment identification forsuspect trunk equipment

testnm MXOR Variable Indicates that MTX originates test callto TAU

MXTM Variable Indicates TAU originates test call toMTX

infotxt CALL COMPLETED Variable Indicates call completed

CALL ABORTED-CHECK LOGS

Variable Indicates system aborted call. Otherlogs generated by the system at thesame time explain the failure.

rslttxt PASS Variable Indicates test passed. Test callcompleted.

FAIL Variable Indicates test failed. System abortedtest call.

Active message example1.ATT117 MAY24 23:42:12 1234 INFO

CKT OWNHA2 1 10

MXOR CALL COMPLETED PASS

Clear message examplen/a

ATT117 523

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 524: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

ATT118The Automatic Trunk Testing (ATT) subsystem generates ATT118 whenreceive signal strength (RSSI) test for mobile telephone exchange (MTX)completes. RSSI uses a test and alarm unit (TAU). Three types of RSSItests are present:

• The control channel RSSI test measures the received signal strengthtransmitted by the TAU to a control channel receiver (CCH). The TAUtransmits signals on a control channel at four signal strengths. TheCCH measures and reports the received signal strength in decibels.

• The voice channel power test measures the received signal strength ona voice channel. The mobile telephone exchange remote carrier unit(MTX RCU) transmits the voice channel to the TAU. The TAUmeasures and reports the received signal strength in decibels.

• Voice channel RSSI and locating receiver RSSI test measures receivedsignal strength transmitted by TAU to a voice channel receiver (VCH).The voice channel RSSI test can run with a locating receiver (LCR).The TAU transmits signals on a voice channel at four signal strengths.The voice channel receiver and the locating receiver measure andreport the received signal strength in decibels.

Remedial actionThis log is for information purposes only.

If rslttxt=PASS, there is no action required.

If rslttxt=FAIL, manually run the test again to collect additional data.

AttributesAttribute Value

Severity Warning

Format1.ATT118 mmmdd hh:mm:ss ssdd INFO

CKT trkid

tstnm tsttxt

524 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 525: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

FAIL Variable Indicates received signal strengthmeasurements are not in acceptablelimits

INFO Constant Fixed Indicates following data provides areport when the RSSI test for themobile telephone exchangecompletes.

CKT Symbolic text Variable Provides equipment identification forsuspect trunk equipment

tstnm MXPW Variable Indicates performance of MTX powermeasurement test.

MXRC Variable Indicates performance of RSSI test forcontrol channel.

MXRV Variable Indicates performance of RSSI test forvoice channel.

tsttxt Variable A minimum of one of the followingvalues appears, according to the typeof test

TX POWER (DB) nnn Variable Provides received signal strengthtransmitted power on a voice channelfrom MTX RCU to TAU in decibels.Displayed when tstnm= MXPW.nnn=signal strength (-130 to -29).

CCH Variable Indicates circuit number of controlchannel that MXRC test uses.Appears when tstnm=MXRC.nnnn=circuit number (0 to 9999).

LCR Symbolic text Variable Indicates circuit number of locatingreceiver that MXRV test uses.Appears when tstnm=MXRV.nnnn=circuit number (0 to 9999).

VCH Symbolic text Variable Indicates use of VCH for MXRC test.Appears when tstnm=MXRC.

ATT118 525

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 526: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

RSSI(DB) Symbolic text Variable Indicates measured received signalstrength transmitted by TAU to device(VCH, LCR or CCH) in decibels.Records results of each of fourtransmission levels. Appears whentstnm=MXRC or MXRV. n1, n2, n3, n4= transmission levels (-130 to -29).

rslttxt PASS Variable Indicates received signal strengthmeasurements in acceptable limits

Active message example1.ATT118 JUL16 10:01:10 8201 INFO

CKT 10THAVE 2

MXRV VCH RSSI dB -65 -75 -85 -95

PASS

LCR 0 RSSI dB -65 -75 -85 -95

Clear message examplen/a

Associated OM registers

ATT119The ATTPL2 subsystem generates ATT119 to indicate the fail status of atransmission loss test. This test involves a 904 test line for MOC licenses.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatATT119 mmmdd hh:mm:ss ssdd INFO AUTOMATIC TRUNK TESTING

(The system only generates ATT119 on an internationalswitch.)

526 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 527: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Field Value Variable Description

INFO AUTOMATICTRUNK TESTING

Variable

(The subsystem onlygenerates ATT119 onan internationalswitch)

Constant Fixed

Active message exampleATT119 APR01 12:00:00 2112 INFO AUTOMATIC TRUNK TESTING

(This log only generates on an international switch.)

Clear message examplen/a

Associated OM registers

ATT120The ATTPL2 subsystem generates ATT120 to indicate a pass status on atransmission loss test. This test involves a T904 test line for MOClicensees.

Remedial actionA future release of this manual will include additional information on thislog report.

AttributesAttribute Value

Severity Warning

FormatATT120 mmmdd hh:mm:ss ssdd INFO AUTOMATIC TRUNK TESTING

(The subsystem only generates ATT120 on an internationalswitch.)

Active message exampleATT120 APR01 12:00:00 2112 INFO AUTOMATIC TRUNK TESTING

ATT120 527

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 528: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

(This log only generates on an international switch.)

Clear message examplen/a

Associated OM registers

ATT121The Automatic Trunk Test (ATT) subsystem generates ATT121 when ATTperforms a Bit Error Rate Test Line (BERTL) on a trunk. The log reportsthe results of the test. The test fails when the results exceed setmaintenance test limit (Q limit).

Remedial actionn/a

AttributesAttribute Value

Severity Warning

Format1.ATT121 mmmdd hh:mm:ss ssdd INFO CKT cktid

tst BER = rate DURATION = n SEC/MINS restxt

ERS = percent TIME INSYNC = n SEC/MINS

SLIPS = slipn

Selected field descriptionsField Value Fixed or

VariableDescription

Q2 Variable Indicates the BERRL test on theindicated circuit failed. The number ofbits in error exceed the set Q limit.(BERQ, ERSQ, or SLIPSQ).

ERS percent 0 to 100 Variable Provides the percentage of thenumber of seconds of test durationwith the number of bits in error.

TIME INSYNC = nSEC/MINS

Integer Variable Indicates the time in sync.

SLIPS = slipn Integer Variable Indicates the number of slips that thesystem detected.

528 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 529: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

INFO CKT cktid Symbolic test Variable Identifies the circuit under test. Referto Table I.

tst TB08 Variable Indicates the BERTL test performed isat a speed of 56K bits/s with a knownpattern of 2047 bits.

TB18 Variable Indicates the BERTL test performed isat a speed of 64K bits/s with a knownpattern of 2047 bits.

BER = rate A number, expressedin scientific notation.(For example, 1.0 x10E-6 means0.000001).

Variable Provides the rate of bits in error to bitsnot in error. 1.0 x 10E-6 means 1 bit in1 million bits is in error.

DURATION = n SEC/MINS

Integer Variable Provides the duration of the test inseconds or minutes.

restxt PASS Variable Indicates the BERTL test on theindicated circuit passed. The numberof bits in error do not exceed the set Qlimit.

Active message example1.ATT121 MAR29 08:45:40 0789 INFO CKT OTMF1 10

TB08 BER = 1.0 x 10E-6 DURATION = 900 SEC/MINS PASS

ERS = 6 % TIME INSYNC = 890 SEC/MINS

SLIPS = 1

Clear message examplen/a

Associated OM registers

ATT122The Automatic Trunk Test (ATT) subsystem generates ATT122 when ATTperforms a bit error rate test line (BERTL) on a trunk. The ATT subsystemgenerates this report when the BERTL on a trunk meets connection failure.The test does not have any results.

Remedial actionn/a

ATT122 529

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 530: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatATT122 mmmdd hh:mm:ss ssdd INFO CKT cktid

tst REASON: rsntxt FAIL

Selected field descriptionsField Value Fixed or

VariableDescription

INFO CKT cktid Symbolic text Variable Identifies the circuit under test. Referto Table I.

tst TB08 Variable Indicates the BERTL test runs at aspeed of 56K bits/s with a 2047 bitpattern.

TB18 Variable Indicates the BERTL test runs at aspeed of 64K bits/s with a 2047 bitpattern.

FAIL Constant Fixed Indicates connection failure.

rsntxt Symbolic text Variable Provides the reason for connectionfailure. Refer to Table Reasons in thislog.

Active message exampleATT122 MAR29 08:60:10 0788 INFO CKT OTMF1 11

TB08 REASON : No test equipment FAIL

Clear message examplen/a

Associated OM registers

ATT123The Automatic Trunk Testing (ATT) subsystem generates ATT123 when asuccessful TL01 digital loop-around line test runs. This test agrees withInternational Telegraph and Telephone Consultative Committee (CCITT)Red Book Rec.O.11 specified loop-around line test at the terminatingoffice.

530 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 531: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The originating digital loop-around line test performs the followingtransmission and noise measurements. According to CCITT Red Bookrecommendation, the system uses a 1020 Hz tone at -10 dBm to performthe transmission test.

Remedial actionIf the value of field rtxt is PASS, there is no action required. If the value offield rtxt is FAIL, manually run the test again to collect additional data.

AttributesAttribute Value

Severity Warning

FormatATT123 mmmdd hh:mm:ss ssdd INFO

CKT trkid

tstnm EML = nn.n DB NML = nn.n DBRN NIAL = nn DBRN

FN_DEV nn.n ? !txt FN_Noise = nn.n rtxt qltxt

NF_DEV nn.n ? !txt NF_Noise = nn.n rtxt qltxt

ANS RCVD = anstxt )

(E16,0,0,,5,0.25,0,0.0533333,1,15,0,0,1,0,-0.3066667,0,1,0,0, 7,0,0,7,0,0,1,0 .12 5,0.125,1,1,0,0.0666667,6))>

Selected field descriptionsField Value Fixed or

VariableDescription

INFO CKT Symbolic text Variable Provides equipment identificationnumber for suspect trunk equipment.

tstnm TL01 Variable Provides test line code for CCITTdigital loop-around test line.

EML Range 0.0 to 36.0 Variable Provide expected measured loss(EML) in decibels. Field EML is anentered value in Table CLLIMTCE,subtable DIAGDATA.

NML 1 to 63 Variable Provides noise maintenance limit(NML) in decibels above referencenoise. Field NML is an entered valuein customer data Table CLLIMTCE

ATT123 531

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 532: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

subtable DIAGDATA. If the noisemeasurement exceeds NML, initiatemaintenance action.

NIAL 1 to 63 Variable Provides noise immediate action limit(NIAL) in decibels above referencenoise. Field NIAL is an entered valuein customer data Table CLLIMTCEsubtable DIAGDATA. If the noisemeasurement exceeds NIAL, initiateimmediate action.

FN_DEV -99.9 to + 99.9 dB Variable Provides far-to-near end lossdeviation in decibels. FN_DEVindicates difference betweenmeasured loss on trunk and EML indecibels.

NF_DEV -99.9 to + 99.9 dB Variable Provides near-to-far end lossdeviation in decibels. NF_DEVindicates difference betweenmeasured loss on trunk and EML indecibels.

FN_NOISE -99.9 to + 99.9 Variable Provides far-to-near end noise powerlevel in decibels above referencenoise power.

NF_NOISE -99.9 to + 99.9 Variable Provides near-to-far end noise powerlevel in decibels above referencenoise power.

?!txt Blank Variable Indicates loss deviation is in Q1 limit.

Variable Indicates noise level measurement isin maintenance level limit.

? Variable Indicates that loss deviation exceedsQ1 limit, but is in Q2 limit. For noisepower level measurement, indicatesnoise power level measurementexceeds maintenance level limit, but isin the immediate action level limit.

! Variable Indicates that loss deviation exceedsQ2 limit. Indicates that noise powerlevel measurement exceedsimmediate action level.

rtxt PASS Variable Indicates test passed. Loss and noisemeasurements are in acceptablelimits.

532 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 533: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

FAIL Variable Indicates test failed. Loss and noisemeasurements are not in acceptablelimits.

q1txt Blank Variable Indicates that transmissionmeasurements are in immediateacceptable limits.

Q1 Variable Indicates transmission measurementsexceed maintenance level limit but arein immediate action level limit. Initiatemaintenance action.

Q2 Variable Indicates transmission measurementsexceed immediate action level limit.Initiate immediate action.

ANS RCVD Y Variable Indicates the system detects anANSWER message from far-end.

N Variable Indicates the system does not detectan ANSWER message from far-end.

Active message example1.ATT123 JUL17 00:03:45 8000 INFO

2. CKT JAP12WN7 0

3. TL01 EML = 0.0 DB NML = 50 DBRN NIAL = 50 DBRN

4. FN_DEV 0.1 FN_Noise = 24 PASS

5. NF_DEV 3.9 ! NF_Noise = 24 FAIL Q2

6. ANS RCVD = Y

Clear message examplen/a

Associated OM registers

ATT124The Automatic Trunk Testing (ATT) subsystem generates ATT124 whenthe system performs the R2 simplified test.

ATT124 533

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 534: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionIf the R2 simplified test fails, determine if the test runs on R2 digital trunks.When the test runs on R2 digital trunks, evaluate the log for additionalinformation.

When the R2 simplified test does not run on R2 digital trunks, remove thetest from the trunks that are not digital.

AttributesAttribute Value

Severity Warning

FormatATT124 mmmdd hh&gml .mm&gml .ss ssdd INFO CKT trkid tstnminfotxt

Selected field descriptionsField Value Fixed or

VariableDescription

INFO CKT Constant Fixed Indicates circuit information follows.

trkid Alphanumeric Variable Indicates specified name of circuit.

tstnm Constant Fixed Indicates R2 simplified test name.

infotxt Alpha Variable Indicates results of R2 simplified test.

Active message exampleATT124 OCT22 02&gml.13&gml.44 9876 INFO CKT R2DOGAB

R2SM TEST PASSED

Clear message examplen/a

Associated OM registers

AUD101The Audit (AUD) subsystem report generates AUD101 when the supportoperating system (SOS) letter audit frees a letter. When the systemqueues the letter on a mailbox for more than three audit cycles, the systemfrees the letter. The audit cycles last for three minutes.

Remedial actionIf reports repeat, contact the next level of support.

534 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 535: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Indeterminate

FormatAUD101 mmmdd hh:mm:ss ssdd EXC LETTER FREED MB AT h1

OWNER hhhh hhhh typenm modnm , LAST WAITER hhhh hhhh prognm

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh . . .

Selected field descriptionsField Value Fixed or

VariableDescription

EXC Constant Fixed Indicates that an exception conditionis present

LETTER FREED Constant Fixed Indicates that the SOS letter auditfreed the letter

MB AT h1 0000 to FFFF Variable Provides mailbox address in datastore

OWNER 0000 to FFFF Variable Identifies mailbox owner

typenm MODULE Variable Indicates that mailbox owner is typeMODULE

PROGRAM Variable Indicates that mailbox owner is typePROGRAM.

modnm Software modulename

Variable Provides additional information for NTor operating company softwaretechnicians.

LAST WAITER 0000 to FFFF Variable Provides program or module name ofmailbox owner

prognm Character string Variable Provides program name of the lastwaiter.

hhhh... 0000 to FFFF Variable The following figure identifies theinformation in this field. Refer to Howto Interpret Hex Tables in AUD andAUDT Log Reports, in the introductionto this document.

Active message exampleAUD101 APR01 12:00:00 2112 EXC LETTER FREED MB AT 00057DDD

OWNER 4082 8018 PROGRAM IOAUDDP, LAST WAITER 808D C001 IOAAP

AUD101 535

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 536: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

00E6 0000 4000 8080 8080 8080 8080 8080 8080 8080 8080...

Clear message examplen/a

Associated OM registers

AUD102The Audit (AUD) subsystem report AUD102 when the support operatingsystem (SOS) letter audit frees a letter. The SOS letter audit frees a letterthat has a mailbox address that is not correct.

Remedial actionIf reports repeat, contact the next level of support.

AttributesAttribute Value

Severity Indeterminate

FormatAUD102 mmmdd hh:mm:ss ssdd EXC LETTER SENT TO BAD MAILBOXFREED

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh ...

Selected field descriptionsField Value Fixed or

VariableDescription

EXC LETTER SENTTO BAD MAILBOXFREED

Constant Fixed Indicates that the SOS letter auditfrees a letter with a mailbox addressthat is not correct.

hhhh... 0000 to FFFF Variable Identifies the information in this field.Refer to How to Interpret Hex Tablesin AUD and AUDT Log Reports, in theintroduction to this document.

Active message exampleAUD102 APR01 12:00:00 2112 EXC LETTER SENT TO BAD MAILBOXFREED

00E6 0000 4000 8080 8080 8080 8080 8080 8080 8080 8080 . . .

Clear message examplen/a

536 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 537: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AUD103The Audit (AUD) subsystem report AUD103 when a system audit discoversthe following:

• a stopped process

• a process that appears to be ready but is not on any support operatingsystem (SOS) ready queue

This log does not normally appear in the field.

Remedial actionContact the next level of support.

AttributesAttribute Value

Severity Indeterminate

Format*AUD103 mmmdd hh:mm:ss ssdd EXC PROCESS audtxt hhhh hhhh

MOD mdnm

Q=hhhh hhhh hhhh hhhh, RDYW=hhhh, TSLICE=hh, NSUSP=hh,

IC=hhhhhhhh

Selected field descriptionsField Value Fixed or

VariableDescription

EXC PROCESS NOT ON Q Variable Indicates process found ready but noton any ready queue.

STOPPED Variable Indicates process found in stoppedstate.

audtxt 0000 to FFFF Variable Provides process identification.

MOD Variable Provides name of entry module ofprocess.

Q 0000 to FFFF Variable Provides first words of queue headersfrom process block.

RDYW 0000 to FFFF Variable Provides ready word from processblock.

AUD103 537

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 538: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

TSLICE 0 to FF Variable Provides time slice from processblock.

NSUSP 0 to FF Variable Provides nosusp ticks from processblock.

IC 0 to FFFFFFFF Variable Provides last executed program storeaddress of process.

Active message example*AUD103 JAN02 13:49:26 8600 EXC PROCESS STOPPED 2108 E01CMOD LGDV

Clear message examplen/a

Associated OM registers

AUD104The Audit (AUD) subsystem generates AUD104 when an audit log detectsa condition that is not normal in the deload list.

Remedial actionIf the subsystem generates the same AUD104 reports, examine relatedreports and perform manual diagnostic tests to isolate the problem. If thesystem continues to generate AUD104, contact the next level of support.

AttributesAttribute Value

Severity Warning

FormatAUD104 mmmdd hh:mm:ss ssdd INFO DELOAD_LIST reastxt

CIRCUIT= CKT trkid MB=hhhh hhhh

Selected field descriptionsField Value Fixed or

VariableDescription

INFO DELOAD_LIST Constant Fixed Indicates detection of a condition thatis not normal in deload list.

reastxt DELOAD LIST FULL Variable Indicates more room is not availableon deload list.

538 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 539: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

DUPLICATE ENTRY Variable Indicates attempt to add entry alreadyin deload list.

INCORRECTMAILBOX

Variable Indicates entry found on deload listwith mailbox that is not correct.

STATE NOT CPD Variable Indicates circuit found that is not instate call processing deload (CPD).Occurs when circuit posts from trunktest position (TTP) or line test position(LTP) MAP level.

CIRCUIT Symbolic text Variable Identifies affected trunk equipment.

MB 0000-FFFF Variable Identifies mailbox that the circuit uses.

Active message exampleAUD104 APR01 12:00:00 2112 INFO DELOAD_LIST DELOAD LIST FULL

CIRCUIT= CKT RTP2W 2 MB= E111 901A

Clear message examplen/a

Associated OM registers

AUD105The Audit (AUD) subsystem generates report AUD105 when the signalingconnection control part audit detects an error in the local subsystem data.The LSS field indicates the local subsystem at which the audit detects theerror.

The section describes the problems and actions in the log report:

• Local SCMG routing status is NOT AVAILABLE - Routing status set toAVAILABLE.

• Routing status for OFFL or MBSY subsystem not correct - Routingstatus set to prohibited.

• Local SCMG subsystem not RTS - SCMG is RTS.

A list of local subsystem names follows:

• SS UNKNOWN

• SCMG*TUP

• ISDNUP*OAM

AUD105 539

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 540: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• E800

• E800TEST

• ACCS

• N00TEST*TCN

• TCNTEST

• ACCSTEST

Remedial actionThe audit process corrects any detected errors. To report repeatedoccurrences of problems, contact the next level of support.

AttributesAttribute Value

Severity Warning

FormatAUD105 mmmdd hh:mm:ss ssdd INFO SCCP LOCAL SUBSYSTEM

LSS: substxt

PROBLEM: probtxt

ACTION: acttxt

Selected field descriptionsField Value Fixed or

VariableDescription

INFO SCCP LOCALSUBSYSTEM

Constant Fixed Indicates that the signaling -connection control part detects anerror in the local subsystem.

LLS Symbolic text Variable Indicates the local subsystem at whichthe audit detects the error. Refer toTable Local subsystems at the end ofthis log report.

PROBLEM Descriptive text Variable Indicates the problems that the auditencounters. Refer to Table Problemsat the end of this log report.

ACTION Descriptive text Variable Indicates action that occurred. Referto Table Problems at the end of thislog report.

540 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 541: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleAUD105 JAN02 17:35:48 1300 INFO SCCP LOCAL SUBSYSTEM

LSS: SCMG

PROBLEM: Local SCMG routing status is NOT AVAILABLE

ACTION: Routing status set to AVAILABLE

Clear message examplen/a

Associated OM registers

AUD106The Audit (AUD) subsystem generates AUD106 when signaling connectioncontrol part (SCCP) audit detects an error in the remote subsystem data.The RPC field indicates the name of the remote point code as defined inTable C7NETSSN.

This field can remain blank if the system cannot associate the detectedproblem with a separate point code. The RSS field indicates the remotesubsystem where the audit detects the error.

This section describes problems and actions in the log report:

• Subsystem routing status for OFFL or MBSYSS is not correct - Systemsets subsystem routing status to PROHIBITED.

• SCMG routing status for PROHIBITED PC is not correct - System setsSCMG routing status to PROHIBITED.

• SST active for PROHIBITED Point Code - System deactivates SST.

• SST active for non-PROHIBITED Subsystem - System sets subsystemrouting status to PROHIBITED.

• SST inactive for PROHIBITED Subsystem - SST is active.

• Translation for replicated PROHIBITED Subsystem is not correct -System sets translation status that is not correct to BACKUP.

• Translation for replicated AVAILABLE Subsystem that is not correct -System sets subsystem translation status to NORMAL.

• Translation for non-replicated Subsystem is not correct - System setssubsystem translation to NORMAL.

• Missing PERM data record for Subsystem - System resets PERM dataand sets subsystem routing status to PROHIBITED.

AUD106 541

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 542: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• PERM data present for unequipped subsystem - System deletes thePERM data record.

• SCMG routing status for non-PROHIBITED PC that is not correct -System sets SCMG routing status to AVAILABLE.

• SCMG routing status for PROHIBITED PC is not correct - System setsSCMG routing status that is not correct to PROHIBITED.

• SST active for SCMG subsystem - System deactivates SCMG SST.

• Translation status for SCMG subsystem is not correct - Systems setsSCMG translation status to NORMAL.

• Missing PERM data record for SCMG - System resets the SCMGPERM data.

• NO PROT data record for SCMG subsystem - System resets theSCMG PROT and PERM data.

Remedial actionThe audit process corrects any detected errors. Report repeated problemsto the next level of maintenance.

AttributesAttribute Value

Severity Warning

FormatAUD106 mmmdd hh:mm:ss ssdd INFO SCCP REMOTE SUBSYSTEM

RPC: clli RSS: substxt

PROBLEM: probtxt

ACTION: acttxt

Selected field descriptionsField Value Fixed or

VariableDescription

INFO SCCPREMOTESUBSYSTEM

Constant Fixed Indicates that the SCCP audit detectsan error in the remote subsystemdata.

RPC Symbolic text Variable Indicates the name of the remote pointcode as defined in Table C7NETSSN.

542 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 543: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

RSS Character string Variable Indicates the remote subsystemwhere the audit detected the error.Refer to Table Local subsystem at theend of this log report.

PROBLEM Descriptive text Variable Indicates the error that occurred.Refer to Table Problems at the end ofthis log report.

ACTION Descriptive text Variable Indicates action taken. Refer to TableProblems at the end of this log report.

Active message exampleAUD106 JAN02 17:57:43 1000 INFO SCCP REMOTE SUBSYSTEM

RPC: TORONTO RSS: E800

PROBLEM: Invalid subsystem routing status for OFFL or MBSYS

ACTION: Subsystem routing status set to PROHIBITED

Clear message examplen/a

Associated OM registers

AUD107The Audit (AUD) subsystem generates AUD107 when signaling connectioncontrol part (SCCP) audit detects an error in remote point code data.

The RPC field indicates the name of the remote point code as defined inTable C7NETSSN. The field can remain blank if the system cannotassociate the detected error with a given point code.

This section describes problems and actions in the log report:

• PROT data not present - The system deallocates PERM block.

• PERM data block not present - The system deallocates PERM block.

• PROT data record not present - The system clears PERM data.

• PERM data record not present - The system resets PERM data.

AUD107 543

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 544: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• Routing status for OFFL or MBSY PC is not correct - The system setsPC routing state to PROHIBITED.

• Congestion level for PROHIBITED PC is not correct - The system setsPC congestion level to 0.

Remedial actionThe audit process corrects detected errors. Report repeated problems tothe next level of support.

AttributesAttribute Value

Severity Warning

FormatAUD107 mmmdd hh:mm:ss ssdd INFO SCCP REMOTE POINT CODE

RPC: clli

PROBLEM: probtxt

ACTION: acttxt

Selected field descriptionsField Value Fixed or

VariableDescription

Field Value Variable Description

INFO SCCPREMOTE POINTCODE

Constant Fixed Indicates the SCCP audit detects anerror in the remote point code data

RPC Symbolic text Variable Indicates the name of the remote pointcode as defined in Table C7NETSSN.

PROBLEM Description Variable Indicates the system detects aproblem. Refer to Table Problems atthe end of this log report.

ACTION Description Variable Indicates the system takes action.Refer to Table Problems at the end ofthis report.

Active message exampleAUD107 JAN02 17:40:48 9100 INFO SCCP REMOTE POINT CODE

RPC: TORONTO

544 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 545: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

PROBLEM: No PROT data block

ACTION: PERM block has been deallocated

Clear message examplen/a

Associated OM registers

AUD108The Audit (AUD) subsystem AUD108 when the subsystem detects aproblem with Table Internal MEM Selector. The reason code in the logindicates the reason for each occurrence in the log. The remaining parts ofAUD108 provide additional information that relates to a given reason code.

Remedial actionThere is no action required. This log indicates the errors that the auditprocess detects. The audit process corrects the detected error in theinternal Table TRUNK_MEMSEL_TAB. Forward any occurrences of thislog, with important information, to the next support level.

AttributesAttribute Value

Severity Warning

FormatAUD108 mmmdd hh:mm:ss ssdd INFO INTERNAL MEM SELECT TAB LOG

REASON text

CURR_ENTRIES aaaa

CURR_MAX_SIZ bbbb

TC_COUNT ccc

AUDIT_COUNT ddd

RTEREF_TABLE eeee

AUD108 545

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 546: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFO INTERNALMEM SELECT TABLOG

Constant Fixed Indicates the following data provides areport when the system detects aproblem with this table.

REASON AUDIT - TRKMEMOCCURS ASMEM_SELECT INEXCESS OF 255TIMES

Variable Indicates that the audit detects asingle trunk member entered as aMEM select route a minimum of 255times.

AUDIT -MEM_SELECTORMISSING FROMINTERNAL MEMSELECT TAB

Variable Indicates that the audit detects a trunkmember entered as a MEM selectroute. An entry for the trunk memberis not present in Table Internal MEMSelector.

AUDIT - INTERNALMEM SELECTCOUNT ERRORDETECTED/CORRECT ED

Variable Provides the count in Table InternalMEM Selector for number of times thetrunk member occurs as a MEM selectroute. The number of times the sametrunk member occurs as MEM selectroute in route tables can be different.The audit is the reason for thisdifference.

AUDIT - MEM SELENTRY IN INTERNALMEMSEL TAB, NOTIN RTEREF

Variable Indicates an entry is present in theinternal MEM selector table. The routetables do not contain an associatedMEM select route for the entry.

CURR_ENTRIES Integers Variable Indicates the current number ofdifferent trunk members entered in theroute tables as MEM select routes.

CURR_MAX_SIZ Integers Variable Indicates the maximum number ofentries that the system allocates forthe data store.

TC_COUNT Integers Variable Provides the number of times thesystem uses a single trunk member asa MEM select route. Table InternalMEM Select records this count.

AUDIT_COUNT Integers Variable Provides the number of times thesystem uses a single trunk member asa MEM select route. The audit recordsthis count.

RTEREF_TABLE Integers Variable Indicates active audits. TableRTEREF records the active audits.

546 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 547: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleAUD108 JAN01 08:00:02 1367 INFO INTERNAL MEM SELECT TAB LOG

REASON AUDIT - TRKMEM OCCURS AS MEM_SELECT IN EXCESS

OF 255 TIMES

CURR_ENTRIES 0130

CURR_MAX_SIZ 0256

TC_COUNT 255

AUDIT_COUNT 255

RTEREF_TABLE N/A

Clear message examplen/a

Associated OM registers

AUD120The Audit (AUD) subsystem generates log AUD120 to report the results ofthe system audit (SYSAUD) process, each hour. SYSAUD is the SupportOperating System (SOS) letter audit.

Remedial actionn/a

AttributesAttribute Value

Severity Indeterminate

FormatAUD120 mmmdd hh:mm:ss ssdd SUMM HOURLY AUDIT REPORT

NUM AUDITS = nnnn, NUM ERRORS = nnnn, NUM TRAPS = nnnn

AUD120 547

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 548: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

SUMM HOURLYAUDIT REPORT

Constant Fixed Indicates SYSAUD report each hour.

NUM AUDITS = nnnn 0-9999 Variable Provides number of audits the systemperformed in last hour.

NUM ERRORS =nnnn

0-9999 Variable Provides number of errors the systemfound in last hour.

NUM TRAPS = nnnn 0-9999 Variable Provides number of times auditprocess trapped in last hour.

Active message exampleAUD120 APR01 12:00:00 2112 SUMM HOURLY AUDIT REPORT

NUM AUDITS = 5, NUM ERRORS = 0, NUM TRAPS = 0

Clear message examplen/a

Associated OM registers

AUD394This report is generated under the following conditions:

• the RSDT audit process finds one or more RSDTLINE tuples with datainconsistencies.

• when the command RSDT ACT or RSDT DEACT is executed andthere are inconsistencies in table RSTLINE tuples.

• when command RSDT CHGDN or RSDT CHGLN is executed.

The audit system process totals all the errors reported by all auditprocedures executed each hour and generates a report in the AUD120 log.The maximum number of errors that can be reported by the RSDT auditprocess is 20 000.

548 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 549: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

This section explains problems and actions in the log report:

• ERROR :LEN MUST BE PRESENT IN TABLE LNINVACTION:RSDTLINE HAS BEEN DELETED - No further action required. LEN has beenremoved from table RSDTLINE due to missing datafill in table LNINV.

• ERROR :LEN MUST BE PRESENT IN TABLE LNINVACTION:RSDTLINE SHOULD BE DELETED - Action required. LEN has no tableLNINV tuple and RSDT_ENABLED is set to N. Check datafill anddelete if necessary.

• ERROR :LEN MUST BE PRESENT IN TABLE LNINVACTION:RSDTLINE CANNOT BE DELETED - Possible action required. LEN has noLNINV tuple. Report problem to Nortel if log continues to be generated.

• ERROR :LEN MUST BE PRESENT IN TABLE LNINVACTION:FAILEDTO WRITE TO PROTECTED STORE - No further action required. LENcould not be removed from RSDTLINE due to an IMAGEDUMP inprogress. The next audit cycle should correct the problem.

• ERROR :LINE DATA IS NOT SUPPORTED BY RSDTACTION:RSDTLINE HAS BEEN DELETED - No further action required. LEN has beenremoved from table RSDTLINE due to an unsupported line data.

• ERROR :LINE DATA IS NOT SUPPORTED BY RSDTACTION:RSDTLINE SHOULD BE DELETED - Action required. Line data of LEN is notsupported by RSDT, but RSDT_ENABLED is set to N. Check datafilland delete if necessary.

• ERROR :LINE DATA IS NOT SUPPORTED BY RSDTACTION:RSDTLINE CANNOT BE DELETED - Possible action required. Line data ofLEN is not supported by RSDT. Investigate datafill and report problemto Nortel if problem continues to be generated.

• ERROR :LINE DATA IS NOT SUPPORTED BY RSDTACTION:FAILEDTO WRITE TO PROTECTED STORE - No further action required. LENcould not be removed from table RSDTLINE due to an IMAGEDUMP isin progress. The next audit cycle should correct this problem.

• ERROR :CARDCODE NOT SUPPORTEDACTION:RSDT LINE HASBEEN DELETED - No further action required. LEN has been removedfrom table RSDTLINE due to an unsupported CARDCODE in tableLNINV.

• ERROR :CARDCODE NOT SUPPORTEDACTION:RSDT LINESHOULD BE DELETED - Action required. LEN has an unsupportedCARDCODE in table LNINV and RSDT_ENABLED is set to N. Checkdatafill and delete if necessary.

AUD394 549

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 550: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• ERROR :CARDCODE NOT SUPPORTEDACTION:RSDT LINECANNOT BE DELETED - Possible action required. LEN has anunsupported CARDCODE in table LNINV. Investigate datafill andreport problem to Nortel if log continues to be generated.

• ERROR :CARDCODE NOT SUPPORTEDACTION:FAILED TO WRITETO PROTECTED STORE - No further action required. LEN could notbe removed from RSDTLINE due to an IMAGEDUMP in progress. Thenext audit cycle should correct the problem.

• ERROR :INCOMPATIBLE LINE STATUS FOR RSDTACTION:RSDTLINE HAS BEEN DELETED - No further action required. LEN has beenremoved from table RSDTLINE due to an unsupported STATUS inLNINV.

• ERROR :INCOMPATIBLE LINE STATUS FOR RSDTACTION:RSDTLINE SHOULD BE DELETED - Action required. LEN has anunsupported STATUS in LNINV and RSDT_ENABLED is set to N.Check datafill and delete if necessary.

• ERROR :INCOMPATIBLE LINE STATUS FOR RSDTACTION:RSDTLINE CANNOT BE DELETED - Possible action required. LEN has anunsupported STATUS in LNINV. Report problem to Nortel if logcontinues to be generated.

• ERROR :INCOMPATIBLE LINE STATUS FOR RSDTACTION:FAILEDTO WRITE TO PROTECTED STORE - No further action required. LENcould not be removed from RSDTLINE due to an IMAGEDUMP inprogress. The next audit cycle should correct the problem.

• ERROR :INCOMPATIBLE LCC FOR RSDT LINEACTION:RSDT LINEHAS BEEN DELETED - No further action required. LEN has beenremoved from RSDTLINE due to an unsupported LCC.

• ERROR !INCOMPATIBLE LCC FOR RSDT LINEACTION:RSDT LINESHOULD BE DELETED - Action required. LEN has an unsupportedLCC and RSDT_ENABLED is set to N. Check datafill and delete ifnecessary.

• ERROR !INCOMPATIBLE LCC FOR RSDTLINEACTION:RSDT LINECANNOT BE DELETED - Possible action required. LEN has anunsupported LCC. Investigate datafill and report problem to Mortel iflog continues to be generated.

• ERROR :INCOMPATIBLE LCC FOR RSDT LINEACTION:FAILED TOWRITE TO PROTECTED STORE - No further action required. LENcould not be removed from RSDTLINE due to an IMAGEDUMP inprogress. The next audit cycle should correct the problem.

• ERROR :INCOMPATIBLE OPTION FOR RSDT LINEACTION:RSDTLINE HAS BEEN DELETED - No further action required. LEN has beenremoved from RSDTLINE due to an unsupported hunt group.

550 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 551: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• ERROR :INCOMPATIBLE OPTION FOR RSDT LINEACTION:RSDTLINE SHOULD BE DELETED - Action required. LEN has anunsupported hunt group and RSDT_ENABLED is set to N. Checkdatafill and delete if necessary.

• ERROR : INCOMPATIBLE OPTION FOR RSDT LINEACTION: RSDTLINE CANNOT BE DELETED - Possible action required. LEN has anunsupported hunt group. Investigate datafill and report problem toMortel if log continues to be generated.

• ERROR : INCOMPATIBLE OPTION FOR RSDT LINEACTION:FAILED TO WRITE TO PROTECTED STORE - No further actionrequired. LEN could not be removed from RSDTLINE due to anIMAGEDUMP in progress. The next audit cycle should correct theproblem.

• ERROR :INVALID RSDT STATEACTION:RSDT STATE HAS BEENSET TO UNDEFINED - No further action required. The STATE fieldhas been set to UNDEFINED

• ERROR : INVALID RSDT STATEACTION: RSDT STATE HAS BEENSET TO ELIGIBLE - No further action required. The state field hasbeen set to ELIGIBLE.

• ERROR :INVALID RSDT STATEACTION:RSDT STATE HAS BEENSET TO IN_EFFECT - No further action required. The STATE field hasbeen set to iN_EFFECT.

• ERROR :INVALID RSDT STATEACTION:RSDT STATE ISIN_EFFECT BUT RTS FAILED - Action required. Check the state ofthe line and attempt to RTS it if possible.

• ERROR :INVALID RSDT STATEACTION:RSDT STATE CANNOT BESET TO IN_EFFECT - Action required. An attempt to RTS the lines asIN_EFFECT has failed. Investigate datafill and attempt to correctmanually. Report problem to Nortel if log continues to be generated.

• ERROR :INVALID RSDT STATEACTION:FAILED TO DELETELENLINES ENTRY - Action required. Investigate datafill and attempt tocorrect manually. Report problem to Nortel if log continues to begenerated.

• ERROR :LINE IS CORRUPTEDACTION:FAILED TO WRITE TOPROTECTED STORE - No further action required. Line corruptioncould not be determined or corrected due to an IMAGEDUMP inprogress. The next audit cycle should correct this problem.

• ERROR :LINE IS CORRUPTEDACTION:CORRUPTION COULD NOTBE CORRECTED - Possible action required. The line has beencorrupted. Investigate datafill and report problem to Nortel if logcontinues to be generated.

AUD394 551

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 552: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• ERROR :WRONG LINE ATTRIBUTEACTION:LINE ATTRIBUTE HASBEEN UPDATED - No further action required. The line attribute indexhas been corrected.

• ERROR :WRONG LINE ATTRIBUTEACTION:FAILED TO UPDATELENLINES ENTRY - Action required. Investigate datafill and attempt tocorrect manually. Report problem to Nortel if unsuccessful or logcontinues to be generated.

• ERROR :INCORRECT STATE AND LINE ATTRIBUTEACTION:STATEIN_EFFECT, LINE ATTRIBUTE UPDATED - No further action required.The STATE field has been set to IN_EFFECT and the Iine attributeindex has been corrected.

• ERROR :INCORRECT STATE AND LINEATTRIBUTEACTION:FAILED TO UPDATE LENLINES ENTRY - Actionrequired. Investigate datafil and attempt to correct manually. Reportproblem to Nortel if unsuccessful or log continues to be generated.

• ERROR :INCORRECT DN AND LINE ATTRIBUTEACTION:DN ANDLINE ATTRIBUTE HAVE BEEN UPDATED - No further action required.The DN and line attribute index has been corrected.

• ERROR :INCORRECT DN AND LINE ATTRIBUTEACTION: FAILEDTO UPDATE LENLINES ENTRY - Action required. Investigate datafilland attempt to correct manually. Report problem to Nortel ifunsuccessful or log continues to be generated.

• ERROR : NO RSDT DN IN TABLE DNROUTEACTION:RSDT_ENABLED SHOULD BE SET TO N - Perform the followingsteps "Enter command RSDT DEACT, Add an RSDT DN to tableDNROUTE, and then Enter command RSDT ACT".

• ERROR :IMPROPER LINE STATEACTION: RSDT STATE CANNOTBE SET TO UNDEFINED - Action required. The RSDT IN_EFFECTline cannot be set to UNDEFINED because the line is CP busy. It isrecommended that the command RSDT AUDIT be used when the linebecomes IDLE.

Remedial actionThe message text describes the process invoked to correct the error andwhether or not it was successful. All corrective action should be verified toensure that problem has been corrected in table RSDTLINE or anyassociated table. If the problem was not corrected, the next audit cyclemay correct the inconsistency, or it may be necessary to follow theinstructions specified in the ACTION field to correct the problem manually.

552 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 553: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

Format*AUD394 mmmdd hh:mm:ss ssdd INFO RSDTLINE AUDIT REPORT

LEN: len OLDSTATE = preaudit state

ERROR: probtxt

ACTION: actxt

Selected field descriptionsField Value Fixed or

VariableDescription

INFO RSDTLINEAUDIT REPORT

Constant Fixed Indicates that the RSDTLINE auditsystem detects an error in theRSDTLINE table.

LEN Symbolic text Variable Indicates the line equipment numberof the line with the error condition.

OLD STATE Character string Variable Indicates the LEN state in tableRSDTLINE before the audit process(IN_EFFECT, ELIGIBLE, orUNDEFINED).

ERROR Descriptive text Variable Indicates the error that has occurred.See the Problem/Action table at theend of this report.

ACTION Descriptive text Variable Identifies what has been attempted bythe system to correct the error. If thesystem cannot correct the error, it maybe necessary for the user to takeaction. See the Problem/Actionsection at the end of this report.

Active message example*AUD394 mmmdd hh:mm:ss ssdd INFO RSDTLINE AUDIT REPORT

LEN: 1HSOT 00 1 00 08 OLDSTATE = IN_EFFECT

ERROR : IMPROPER LINE STATE

ACTION : RSDT STATE CANNOT BE SET TO UNDEFINED

AUD394 553

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 554: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

AUD395The Audit (AUD) subsystem generates an AUD log report when callprocess stops with no warning. A call process normally stops withoutwarning if an error is present in the system software. Call process also canstop if the system software does not compensate for a feature use errorthat the end user makes. The AUD log report indicates call processingresources cleaned up in a manner that is not normal. This does not alwaysaffect service to the end user.

The system generates some AUD sequences when the parties of aconference call hang up in a given order. After the parties finish theconference and go on-hook. The software can be not able to clearresources that the call used. Because the call is over, the AUD sequenceis transparent to the end user. Repeated AUD4XX or AUD5XX log reportsshow a translation or software problem. The two main AUD logs thatprovide information in these conditions are the AUD395 and AUD398reports. These audit logs work together.

The AUD395 report is a hexadecimal model of the call condense block(CCB). A separate CCB is present for each call in progress on DMSequipment. The system stores call characteristics DMS system software touse when the software processes the call. This information includes thefollowing:

• agent name for the originating and terminating agent in the call

• any required billing

• if all digits are present

• translation information

• called digits

• calling directory number or trunk billing number

• if features are in effect

• routing information

The information in the CCB can help to construct again the event thatcaused the AUD395 report.

554 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 555: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The AUD398 report is a hexadecimal model of the call data block (CDB).The CDB stores additional information for call processing software tocomplete the call. The CDB contains important problem solving elements.The message type and message body contain the last message the callprocess received before both the AUD395 and AUD398 output. Any of thefollowing can occur: DIGITS_MSG, CALL_ERROR_MSG,CLEAR_FORWARD_MSG, INTEGRITY_LOST_MSG.

Both the AUD395 and AUD398 log reports give information common to allcall processes when the system activates features against a call process.These log reports also store additional information for specific features.

These stored features are called extension (EXT) blocks. Each EXT blockhas a system wide setting for stored data. The AUD4XX and AUD5XX logreports are hexadecimal models for the EXT block data. These log reportsare the only AUD log reports. An AUD395 or AUD398 report can have anassociated EXT block (AUD4XX or AUD5XX) report.

There can be other logs for these AUD reports. These logs contain TRAPand/or software error (SWER) reports. These reports, along with the AUDreports can determine profiles on the calls in question. Use the CALLIDfield on the report to link these AUD logs together. The CALLID appears inthe TEXT field in some SWER reports. The AUD395 log report associateswith the SWER100 report with the same CALLID or with a CC103 TRAPreport. Save all log reports that occur at the same time as AUD395 orAUD398 reports. The log reports can construct again the event that causedthe system to generate the report.

The DISPCALL system solves problems in log reports. The DISPCALL is aresident tool that formats the following blocks into a data model:

• AUD395

• AUD398

• some AUD4XX

For more information about DISPCALL, refer to Display Call User Guide,TAM-1001-003.

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

AUD395 555

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 556: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionMany AUD395 reports that repeat indicate a translation problem or asoftware problem. Perform the following four steps when on-site personneldecide to use problem solving to respond to repeated call failures.

• Look for TRAP (CC103) and SWER (SWER 100) log reports. ManyAUD395 reports that indicate system trouble associate with TRAPs orSWERs.

• Examine agent IDs in the PORT1PERM and PORT2PERM fields.These fields identify the calling and called agents. More than oneAUD395 log report with the same originator and terminator indicatesthat you localized the problem.

• Examine the call processing selectors for PORT1PERM andPORT2PERM. These fields can identify the types of lines involved inthe call. If several log reports specify a type of line, it can be animportant indication.

• Examine evidence to decide if the problem relates to corrupt datatables. Examples of the problem in the data tables can be in thetranslation, or the code. Contact software support personnel if yoususpect the code.

AttributesAttribute Value

Severity Warning

FormatAUD395 mmmdd hh:mm:ss ssdd INFO CCB DUMP

CALLID: callid

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh...

Selected field descriptionsField Value Fixed or

VariableDescription

INFO CCB DUMP Constant Fixed Indicates this report is data dump ofCCB.

CALLID Symbolic text Variable Identifies the call process stopped.

hhhh... 0000 - FFFF Variable The following figures identify theinformation in this field. Refer to "Howto Interpret Hex Tables in AUD andAUDT Log Reports", in theintroduction to this document.

556 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 557: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleAUD395 JAN13 12:00:00 2112 INFO CCB DUMP

CALLID: 655363 (WORDS

FFFF FFFF 0063 C201 FFFF FFFF FFFF FFFF FFFF FFFF 0-9

FFFF 0000 FFFF FFFF 00C2 00DE 0000 0000 0028 0410 10-19

FFFF FFFF 3C1C 1600 00FF FF50 023F 0A29 0015 0B1C 20-29

6BD9 9C00 6BD8 9C00 8536 9800 FE00 FFFF FFFF FFFF 30-39

08A5 0000 FFFF FFFF 0052 0C00 08A7 7F48 0407 040B 40-49

0022 2607 3259 9400 9100 9400 C688 9300 3261 9400 50-59

FE05 FFFF 08CF 0000 3873 0C07 0000 0000 0002 2E0B 60-69

1226 F432 FFFF FFFF 47FF FD01 8002 FFFF FFFF FFFF 70-79

0AAA 0000 0000 0000 0000 0000 0000 0000 0000 0000 80-89

0000 0002 0200 0041 0010 0000 0000 0000 0000 0000 90-99

0002 2E0B 4005 1000 0415 0415 0000 0000 0050 03E7 100-109

0000 0000 0000 0000 0000 0000 0EDE 0003 0000 0000 110-119

0000 000A 0504 8000 120-123

Clear message examplen/a

Associated OM registers

AUD396The Audit (AUD) subsystem generates log report AUD396 when the callprocessing base software detects the abnormal termination of a callprocess. The occurrence of a call death can affect service. The AUD396 isan information log and provides support personnel with additional data.Additional data can help support personnel isolate the cause of a calldeath.

Support personnel use this log to debug call deaths. The information is notimportant for operating company personnel. Other than collection of thedata, support personnel must not take action. When support personnel

AUD396 557

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 558: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

collect this data, support personnel must collect the AUD396 log. Supportpersonnel must collect all other logs with the same CALLID. Other logswith the same CALLID include AUD395 and AUD398. Support personnelmust attach the SWERS that relate to the death. The SWERS can have areason in the set, (101, 102, 103, 104, 105). The system can generateadditional SWERS. Support personnel must include these additionalSWERS.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatAUD396 mmmdd hh:mm:ss ssdd INFO CALL THREAD DUMP

CALLID: <callid>STARTER: <starter string>

THR1: <thread1>THR2: <thread2>CMI: <cross_matrix_index>

MESSAGE TYPE: <mt>CALL STATE: <cs>

Selected field descriptionsField Value Fixed or

VariableDescription

CALLID 0000-FFFF Variable Indicates different call sequenceidentification for each call.

STARTER Variable Variable Indicates the application Starter thatthe system invoked to process thecall. An example of an applicationstarter is a line or a trunk.

THR1 0 to 511 Variable Provides the index of the thread tablefor the originating agent.

THR2 0 to 511 Variable Provides the index of the thread tablefor the terminating agent.

CMI 0 to 1023 Variable Indicates the cross matrix index isobtained when both originating orterminating agents are known.

558 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 559: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

MESSAGE TYPE 0000-FFFF Variable Indicates the nature of the event thatthe call process and applicationsoftware undertake. The STARTERand the call state determines theprocessor/function to invoke next.

CALL STATE IDLE Variable Indicates call status as Idle and new.

ORIGINATION Variable Indicates receiver requested.

RECEIVING Variable Indicates digit reception, notcondensed.

DIALLING Variable Indicates condensed, waiting fordigits.

OUTPULSING Variable Indicates outpulsing.

OVLPULSING Variable Indicates overlapped, outpulsing andreception.

TALKING Variable Indicates network connectionestablished, call condensed.

TWOWAYCON Variable Indicates two-way net connection, notcondensed.

ONEWAYCON Variable Indicates one-way network connection(ex announcement).

MULTIPORT Variable Indicates a multiparty call.

SERVICETONE Variable Indicates service tone (re-order).

TERMTONE Variable Indicates generated audible ring orbusy tone, or talking in fast call.

HELD Variable Indicates special state whencondensed in feature call.

TESTING Variable Indicates special state that audit doesnot time.

TRANSIENT Variable Indicates transient state with callprocess.

PREEMPTING Variable Indicates call preempted - Autovonuse only.

CUSTOM Variable Indicates custom calling feature.

WAITING Variable Indicates condensed when timingperformed.

ORIGTONE Variable Indicates originator rings or receivestone, not a 1 port call.

PFHELD Variable Indicates for P-Phone.

AUD396 559

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 560: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

SETUP Variable Drive all messages to setup procedurefrom starter.

XPROC Variable Drive all messages from starter tocross procedure.

PRESERVED Variable Indicates calls preserved over warmSwitch of Activity (SWACT), linemodule (LM)/remote line module(RLM) warm.

ONE_END_DISC Variable Waits for disconnect of last agent inthe call.

DORMANT Variable Indicates call condense block (CCB)links to the multi-condense(DORMANTTID).

COLLECTING Variable Use for MF to SS7 FGD call to collectdigits.

WAITALERT Variable Use for integrated services digitalnetwork (ISDN) calls to wait foralerting.

WAITRLS Variable Use for ISDN calls to wait for release.

Active message exampleAUD396 JUL12 08:15:17 0201 INFO CALL THREAD DUMP

CALLID:000A 0000 STARTER : LINES

THR1:0002 THR2:0000 CMI:0000

MESSAGE TYPE:0018 CALL STATE : IDLE

Clear message examplen/a

Associated OM registers

AUD398The Audit (AUD) subsystem generates log report AUD398 when a callprocess stops without warning. A call process stops without warningbecause an error in the system software removes the call process. A callprocess can stop without warning because an end user makes a featureuse error. The system software does not compensate for a feature use

560 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 561: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

error that an end user makes. The AUD log reports indicate call processingresources cleaned up in an abnormal manner. This procedure can affectservice to the end user.

The system can generate AUD sequences when parties of a conferencecall hang up in a specified order. The parties finish the conference and goon-hook. The software can have problems clearing resources that the calluses. The AUD sequence is transparent to the end user because the call isfinished. Log reports AUD4XX or AUD5XX that repeat can indicate atranslation problem or a software problem. The AUD395 and AUD398reports provide information about these occurrences.

AUD395 is a hexadecimal design of the call condense block (CCB). Eachcall in progress on DMS equipment has a separate CCB. The DMSequipment for system software stores the following call characteristics touse in the call process:

• the name of the originating and terminating agent in the call

• billing required

• if all digits are present

• translation information

• called digits

• calling directory number (DN) or trunk billing number

• if a feature is in effect

• if the system routes information.

AUD398 is a hexadecimal representation of the call data block (CDB). TheCDB stores additional information for call processing software to completethe call.

The CDB contains one of the most important problem solving elements.The message type and body, contain the last message the call processreceives before the system generates AUD395/398. The last message thecall process receives can be a DIGITS_MSG, CALL_ERROR_MSG,CLEAR_FORWARD_MSG, INTEGRITY_LOST_MSG, etc.

Log reports AUD395 and AUD398 connect in tandem. The AUD395 andAUD398 reports detail information common to all call processes when thesystem activates features against a call process. The system must storeadditional information that is associated with a specified feature. Extension(EXT) blocks store this additional information. Each EXT block has aspecified template for stored data. The AUD4XX and AUD5XX log reports

AUD398 561

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 562: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

are hexadecimal designs for EXT block data. The remainder of the AUDlog reports consists of AUD4XX and AUD5XX. An AUD395 or AUD398report can have an associated EXT block AUD4XX or AUD5XX report.

Other logs can associate with these AUD reports. These logs are normally,but not only, TRAP and/or software reports (SWER) reports. These reportsare important in order to determine a profile on the call in question. Referto the CALLID field in the report to link the AUD logs together. SpecifiedSWER reports have the CALLID in the TEXT field. AUD398 associateswith the SWER100 report that has the same CALLID, or with a CC103TRAP report. Save all log reports that occur at the same approximate timeas an AUD395 or AUD398 report. These log reports can reconstruct theoccurrence that causes the system to generate the report.

The DISPCALL system can troubleshoot log reports. The DISPCALL is aresident tool that formats the AUD395, AUD398, and specified AUD4XXblocks to a data design. For more information about DISPCALL, refer toDisplay Call (DISPCALL) User Guide, TAM-1001-003.

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

Remedial actionAUD398 can indicate a translation or software problem. When onsitepersonnel decide to troubleshoot call deaths that repeat, the following foursteps are recommended.

• Look for TRAP (CC103) and SWER (SWER 100) log reports. AUD398reports that indicate system trouble normally have associated TRAPsor SWERs.

• Examine the agent intermediate dials (IDs). The agent IDs are TID andTERMINAL_CPID. These fields identify the calling and called agents. Ifa minimum of one AUD398 shows the same originator and terminator,you have detected the problem.

• Examine the call processing selectors (CPS). These fields identify thetypes of lines linked to the call. If several log reports indicate that aspecified type of line is linked to the call, the line can be an indication.

• Examine the available data to decide if the problem relates to corruptdata tables. The problem can relate to a translation, or to the code.Contact software support personnel if you suspect the problem relatesto the code.

562 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 563: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatAUD398 mmmdd hh:mm:ss ssdd INFO CDB DUMP

CALLID: callid

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh...

Selected field descriptionsField Value Fixed or

VariableDescription

INFO CDB DUMP Constant Fixed Indicates report is data dump of CDB.

CALLID Symbolic text Variable Indicates call process that stopped.

hhhh... 0000 - FFFF Variable Provides temporary data used whenthe system sets up or takes down acall. The following figure identifiesthese data fields.

Active message exampleAUD398 APR01 12:00:00 2112 INFO CDB DUMP

CALLID: 407 (WORDS:

0ACB 1300 FFFF FFFF 0100 BD89 1500 FFFF FFFF 8088 0 - 9

0010 293A 0000 3AD1 8A97 8930 8080 8080 8080 8080 10 - 19

8080 807C 0020 0008 DFE1 0468 0000 8080 8080 8080 20 - 29

FFFF FFFF 3420 8080 AAAA 1205 2111 3200 80AA 8080 30 - 39

1806 0D48 0000 8080 8080 8000 00C2 0E00 5721 8080 40 - 49

3699 0C07 0D48 8080 85AA F321 BA30 A550 8080 8080 50 - 59

8080 0100 0ACB 63)

Clear message examplen/a

AUD398 563

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 564: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AUD399The Audit (AUD) subsystem generates log report AUD399 if the Call DataBlock (CDB) or a CPLETTER dumps a call. The CDB or CDLETTERdumps points to a long message buffer.

Remedial actionYou must save this log report for analysis. The next level of maintenanceanalyses this log report.

AttributesAttribute Value

Severity Warning

FormatAUD399 mmmdd hh:mm:ss ssdd INFO LONG BUFFER DUMP

CALLID: callid REASON: rsntxt

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

564 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 565: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

Selected field descriptionsField Value Fixed or

VariableDescription

INFO LONG BUFFERDUMP

Constant Fixed Indicates that the subsystem dumpeda long buffer involved with a call orlong message.

CALLID Character string Variable Indicates the call process involved.Refer to Table I.

rsntxt BFP Buffer Notcomplete

Variable Indicates that if the system loses apacket of a long message that BFPpacketizes and transports, themessage cannot assemblecompletely. The long buffer auditdetects this condition.

CDB IOMSG LB Variable Indicates that the system dumped along buffer as part of a call dump. Thesystem must generate other logs forthe call condense block (CCB) and thecall data block (CDB). This reasonappears if CDB.MESSAGE contains apointer to a long message that doesnot equal CDB.CP_GUARDIAN.

CDB Guarded LB Variable Indicates that the system dumped along buffer as part of a call dump. Thesystem must generate other logs forthe CCB and CDB.

LONG MESSAGELOST

Variable Indicates that message transfersystem (MTS) lost a long message.The system dumps partial messagereceived.

hhhh... 0000-FFFF Variable Provides the contents of the longbuffer.

Active message exampleAUD399 APR01 01:01:00 1234 INFO LONG BUFFER DUMP

CALLID: 12345 REASON: BFP Incomplete Buffer

AUD399 565

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 566: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

001C FDFD FDFD FDFD FDFD FDFD FDFD FDFD FDFD FDFD

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

Clear message examplen/a

Associated OM registers

AUD400The Audit (AUD) subsystem generates report AUD400 when a callattempts to free a receiver that another call already owns.

Remedial actionContact the next level of maintenance.

566 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 567: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Indeterminate

FormatAUD400 mmmdd hh:mm:ss ssdd WARN INVALID FREE RECEIVER

RECEIVER trkid CALLID callid

OWNED CALLID callid

Selected field descriptionsField Value Fixed or

VariableDescription

WARN INVALIDFREE RECEIVER

Constant Fixed Indicates call attempted to freereceiver that another call owns

RECEIVER Symbolic text Variable Identifies receiver

CALLID Symbolic text Variable Identifies call that attempts to freereceiver

OWNED CALLID Symbolic text Variable Identifies call that receiver owns

Active message exampleAUD400 APR01 12:00:00 2112 WARN INVALID FREE RECEIVER

RECEIVER CKT RTP2W CALLID 872493

OWNED CALLID 563929

Clear message examplen/a

Associated OM registers

AUD401The Audit (AUDT) subsystem generates this report when the position idlercalls on the audit to dump auxiliary operator services system (AOSS)position data. The position idler requests the dump to help solve a softwareproblem. The callid also is associated with a software error (SWER) orTRAP.

AUD401 567

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 568: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionThese AUD log reports indicate the system cleaned call processingresources in a manner that is not normal. This procedure does not alwaysaffect service to the end user. Repeated AUD4XX or AUD5XX log reportscan indicate a translation or software problem. Most AUD4XX andAUD5XX reports have an associated AUD395 or AUD398 log report.

The AUD395 and AUD398 reports give detailed information common to allcall processes. When features are activated against a call process,additional information about a certain feature must be stored. These areasare called Extension (EXT) blocks. Each EXT block has a fixed templatefor stored data. The AUD4XX and AUD5XX log reports are hexadecimalrepresentations for EXT block data. These log reports are the remainder ofthe AUD log reports.

Save all log reports that occur in one period of time. These logs can helpreconstruct the event which generated the report. Save all logs generatedduring the 5 min before the AUD log report and for 5 min after this report.

• Use the CALLID field associated with this report to look for otherassociated AUD reports. More than one CALLID can be associatedwith an agent if a feature is in effect. An example of a feature is three-way calling (3WC).

• Look for associated TRAP and SWER logs or other logs that can beassociated with this report.

• Use the DISPCALL tool to capture additional failures and provide aformatted dump of the information for AUD395, AUD398, and AUD4XXlogs. The DISPCALL is a resident tool that formats the AUD395,AUD398, and AUD4XX blocks into a data representation. For moreinformation about DISPCALL, refer to Display Call (DISPCALL) UserGuide, TAM-1001-003.

• If you cannot localize and correct the problem, gather the mostinformation possible about the call in question. Contact the next level ofsupport.

AttributesAttribute Value

Severity Warning

FormatAUD401 mmmdd hh:mm:ss ssdd INFO AOSS RU DUMP

trkid CALLID callid (WORDS

568 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 569: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh 0->9

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh 10->19

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh 20->29

hhhh hhhh hhhh hhhh hhhh 30->34

Selected field descriptionsField Value Fixed or

VariableDescription

INFO AOSS RUDUMP

Constant Fixed Indicates this report contains datadump for AOSS position.

trkid Symbolic text Variable Provides equipment identification forsuspect line equipment.

CALLID Symbolic text Variable Provides sequence number of callprocess.

hhhh... 0000 to FFFF Variable Provides 35 words of AOSS positiondata.

Active message exampleAUD401 APR01 12:00:00 2112 INFO AOSS RU DUMP

CKT AOSSPOS 212 CALLID 950298 (WORDS

FFFF FFFF 0012 0000 1001 2200 0000 00C1 0B0 0000 0->9

0000 0000 00C2 0103 0022 0000 0110 0000 00A2 0100 10->19

0011 001D 0000 0024 00A6 0120 0000 0202 0000 003B 20->29

FFFC 01F2 OB30 0000 0300 30->34

Clear message examplen/a

Associated OM registers

AUD402The Audit (AUD) subsystem generates report AUD402. The subsystemgenerates AUD402 when data dump occurs for a REGIONALSEMAPHORE (REGNSEMA) extension block. Extension blocks provideadditional data space for a call condense block (CCB). The CCB storesenough data to describe a call. This report is an associated report for an

AUD402 569

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 570: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AUDT102 report if the AUD402 audit detects a problem. This report is anassociated report for an AUDT399, or AUD398 report when the callprocess stops without warning.

Remedial actionThe AUD log reports indicate a clean up of call processing resources thatwas not normal. This clean up does not always affect service to the enduser. Repeated AUD4XX or AUD5XX log reports can indicate a translationor software problem.

The AUD4XX and AUD5XX reports normally have an associated AUD395or AUD398 log report. The AUD395 and AUD398 reports detail informationDMS-100 Family NA 100 Log Report Reference Manual Volume 1 of 8LET0015 and up common to all call processes. When the user activatesfeatures against the call process, the additional information for a givenfeature must be stored. These areas are Extension (EXT) blocks. EachEXT block has a template for stored data.

The AUD4XX and AUD5XX log reports are hexadecimal representationsfor EXT block data. These log reports form the remainder of the AUD logreports. Save all log reports that occur at the same time. The log reportscan help to reconstruct the event that caused the system to generate thereport.

To reconstruct the type of call, use the tools and templates and theinformation, which the AUD395 or AUD398 sections provide. Use thesetools, templates, and information to determine the problem encountered.The following steps are recommended when onsite personnel deciderepeated call losses justify problem solving.

• Save all logs generated 5 minutes before and after the AUD report.

• Use the callid field for this report to look for associated AUD logs. If afeature is in effect, for example, three-way calling (3WC), more thanone callid can associate with an agent.

• Look for associated TRAP and SWER logs or other logs with thisreport.

• Use the DISPCALL tool to capture failures and provide a formatteddump of information for AUD395, AUD398, and some AUD4XX logs.The DISPCALL is a resident tool that formats the AUD395, AUD398,and some AUD4XX blocks into a data representation. For moreinformation about DISPCALL, refer to Display Call (DISPCALL) UserGuide, TAM-1001-003.

• When you cannot localize and correct the problem, gather all availableinformation about the call in question. For additional help, contact thenext level of technical support.

570 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 571: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatAUD402 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid(WORDhhhh

hhhh hhhh hhhh hhhh hhhh 0-5)

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock,

callid Symbolic text Variable Identifies call process affected.

hhhh... 0000 - FFFF Variable Provides six words of data from theREGNSEMA extension block.

Active message exampleAUD402 APR01 12:00:00 2112 INFO EXT DUMP 419104 (WORDS

1001 FFFF FFFF FFFF FFFF 0-5)

Clear message examplen/a

AUD403The Audit (AUD) subsystem generates report AUD403 when a data dumpfor a PORTEXTPERM extension block exists. A call condense block (CCB)stores only sufficient data to describe a basic call. Extension blocksprovide additional data space for a CCB. This report is an associatedreport for an AUD395 report if the audit detects a problem. This report is anassociated report for an AUD399 report when the call process stopswithout warning.

There is no additional information.

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

AUD403 571

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 572: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionThe AUD log reports indicate a clean up of call processing resources thatwas not normal. This clean up does not always affect service to the enduser. Repeated AUD4XX or AUD5XX log reports can indicate a translationproblem or a software problem.

The AUD4XX and AUD5XX reports normally have an associated AUD395or AUD398 log report. The AUD395 and AUD398 reports detail informationcommon to all call processes. When the user activates features against acall process, the additional information for a given feature must be stored.

These areas are extension (EXT) blocks. Each EXT block has a templatefor stored data. The AUD4XX and AUD5XX log reports are hexadecimalrepresentations for EXT block data. These log reports form the remainderof the AUD log reports. Save all log reports that occur at the same time.The log reports can help to reconstruct the event that caused the system togenerate the report.

To reconstruct the type of call, use the tools and templates and theinformation, which the AUD395 or AUD398 sections provide. Use thesetools, templates, and information to determine the problem encountered.The following steps are recommended when onsite personnel deciderepeated call losses justify problem solving:

• Save all logs generated 5 minutes before and after the AUD log report.

• Use the callid field for this report to look for associated AUD logs. If afeature is in effect, for example, three-way calling (3WC), more thanone callid can associate with an agent.

• Look for associated TRAP and SWER logs or other logs associatedwith this report.

• Use the DISPCALL tool to capture failures and provide a formatteddump of information for AUD395, AUD398, and some AUD4XX logs.The DISPCALL is a resident tool that formats the AUD395, AUD398,and AUD4XX blocks into a data representation. For more informationabout DISPCALL, refer to Display Call (DISPCALL) User Guide,TAM-1001-003.

• When you cannot localize and correct the problem, gather all availableinformation about the call in question, for additional help, contact thenext level of technical support.

AttributesAttribute Value

Severity Warning

572 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 573: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FormatAUD403 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid(WORDhhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh 0-8

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh 9-17

hhhh hhhh hhhh hhhh hhhh hhhh hhhh 18-24)

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock.

callid Symbolic text Variable Identifies call process affected.

hhhh 0000-FFFF Variable Provides 25 words of data from permextension block.

Active message exampleAUD403 APR01 12:00:00 2112 INFO EXT DUMP 419104 (WORDS

1801 0000 0000 0000 7F81 0000 8080 8080 8080 0-8

0000 FFFF FFFF 0000 0000 0500 0000 0000 0000 9-17

5000 8000 0000 0002 0300 0000 0000 18-24)

Clear message examplen/a

Associated OM registers

AUD404The Audit (AUD) subsystem generates report AUD404. The subsystemgenerates AUD404 when a data dump for a INWATS COMMONCHANNEL SIGNALING (INWCCS) recording unit extension block occurs.A call condense block (CCB) stores only sufficient data to describe a basiccall. Extension blocks provide additional data space for a CCB. TheAUD404 associates with the AUDT102 report if the audit detects aproblem. The AUD404 associates with the AUDT399 report if the callprocess stops without a warning. The AUD404 can associate with theAUD398 report.

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

AUD404 573

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 574: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionThe AUD log reports indicate a clean up of call processing resources thatwas not normal. This clean up does not always affect service to the enduser. Repeated AUD4XX or AUD5XX reports can indicate a translationproblem or a software problem.

The AUD4XX and AUD5XX reports normally have an associated AUD395or AUD398 log report. The AUD395 and AUD398 reports detail informationcommon to all call processes. When the user activates features against acall process, the additional information for a given feature needs a storagearea. These areas are extension (EXT) blocks. Each EXT block has atemplate for stored data. The AUD4XX and AUD5XX log reports arehexadecimal representations for EXT block data. These reports form theremainder of the AUD log reports. Save all log reports that occur at thesame time. The log reports can help to reconstruct the event that causedthe system to generate the report.

To reconstruct the type of call, use the tools and templates and theinformation that the AUD395 or AUD398 sections provide. Use these tools,templates, and information to determine the problem encountered.

The following steps are recommended when onsite personnel deciderepeated call losses justify problem solving:

• Save all logs generated five min before and after the AUD report.

• Use the callid field for this report to look for associated AUD logs. If afeature is in effect, for example, three-way (3WC), more than one callidcan associate with an agent.

• Look for associated TRAP and SWER logs or other logs associatedwith this report.

• Use the DISPCALL tool to capture failures and provide a formatteddump of the information for AUD395, AUD398, and some AUD4XXlogs. The DISPCALL is a resident tool that formats the AUD395,AUD398, and AUD4XX blocks into a data model. For more informationabout DISPCALL, Display Call (DISPCALL) User Guide,TAM-1001-003.

• When you cannot localize and correct the problem, gather all availableinformation about the call in question. For additional help, contact thenext level of technical support.

AttributesAttribute Value

Severity Warning

574 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 575: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FormatAUD404 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid (WORDS

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh

0-8

9-17

18-26

27-31)

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock.

callid Symbolic text Variable Identifies call process affected.

hhhh... 0000 - FFFF Variable Provides 32 words of data from theINWCCS extension block.

Active message exampleAUD404 APR01 12:00:00 2112 INFO EXT DUMP 125840 (WORDS

2001 8000 0000 0000 0000 0000 8080 8080 8080 0-8

8080 8080 8080 8080 8080 8080 8080 0000 0000 9-17

2001 8000 0000 0000 0000 0000 8080 8080 8080 18-26

A000 0000 0000 8000 2D6D 27-31)

Clear message examplen/a

AUD404 575

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 576: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AUD405The Audit (AUD) subsystem generates this report when a data dump for anautomatic number identification (ANI) spill block extension block occurs.The AUD405 uses extension blocks to provide additional data space for acall condense block (CCB). A CCB stores only sufficient data to describe abasic call. The AUD405 associates with the AUDT102 report if the auditdetects a problem. The AUD405 associates with the AUDT399 report if thecall process stops without a warning. The AUD405 can associate with theAUD398 report.

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

Remedial actionThe AUD log reports indicate a clean up of call processing resources thatwas not normal. This clean up does not always affect service to the enduser. Repeated AUD4XX or AUD5XX log reports can indicate a translationproblem or a software problem.

The AUD4XX and AUD5XX reports normally have an associated AUD395or AUD398 log report. The AUD395 and AUD398 reports detail informationcommon to all call processes. When the user activates features against acall process, the additional information for a given feature must be stored.These areas are called extension (EXT) blocks. Each EXT block has atemplate for stored data. The AUD4XX and AUD5XX log reports arehexadecimal representations for EXT block data. These reports form theremainder of the AUD log reports. Save all log reports that occur at thesame time. The log reports can help to reconstruct the event that causedthe system to generate the report.

To reconstruct the type of call, use the tools and templates and theinformation, which the AUD395 or AUD398 sections provide. Use thesetools, templates, and information to determine the trouble.

The following steps are recommended when onsite personnel deciderepeated call losses justify problem solving:

• Save all logs generated 5 min before and after the AUD report.

• Use the callid field for this report to look for associated AUD logs. If afeature is in effect, for example, three-way calling (3WC), more thanone callid can associate with an agent.

• Look for associated TRAP and SWER logs or other logs associatedwith this report.

576 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 577: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• Use the DISPCALL tool to capture failures and provide a formatteddump of information for AUD395, AUD398, and AUD4XX logs. TheDISPCALL is a resident tool that formats the AUD395, AUD398, andAUD4XX blocks into a data representation. For more information aboutDISPCALL, Display Call (DISPCALL) User Guide, TAM-1001-003.

• When you cannot to localize and correct the problem, gather allavailable information about the call in question. For additional help,contact the next level of technical support.

AttributesAttribute Value

Severity Warning

FormatAUD405 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid (WORDS

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

0-8

9-17

18-26

27-34)

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock.

callid Symbolic text Variable Identifies call process affected.

hhhh... 0000 - FFFF Variable Provides 34 words of data from theANI spill block extension block.

Active message exampleAUD405 APR01 12:00:00 2112 INFO EXT DUMP 100661 (WORDS

AUD405 577

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 578: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

2801 8080 8080 8080 8080 A080 F9CD 0C00 8080 0-8

0010 8080 3259 9400 0000 2607 FFFF 0415 0002 9-17

1226 0041 0000 0000 00DE 8080 8080 8080 8080 18-26

03E7 0022 0AAA 0000 0000 0000 0000 0000 27-34)

Clear message examplen/a

Associated OM registers

AUD406The Audit (AUD) subsystem generates log report AUD406. The reportappears when a data dump occurs for a traffic operator position servicerecording unit (TOPSRU) extension block. These TOPSRU extensionblocks provide additional data space for a call condense block (CCB). ACCB stores only enough data to describe a basic call.

This report associates with an AUDT102 report if the audit detects aproblem. The report associates with an AUDT399 report if the call processstops without a warning. The report can also associate with an AUD398report.

The following is additional information for log report AUD406:

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

Remedial actionThe AUD log reports indicate a clean up of call processing resources thatwas not normal. This clean up does not always affect service to the enduser. Repeated AUD4XX or AUD5XX log reports can indicate a translationor software problem.

The AUD4XX and AUD5XX reports normally have an associated AUD395or AUD398 log report. The AUD395 and AUD398 reports detail informationcommon to all call processes. When the user activates features against thecall process, the additional for a given feature must be stored. These areasare extension (EXT) blocks. Each EXT block has a template for storeddata. The AUD4XX and AUD5XX log reports are hexadecimalrepresentations for EXT block data. These reports form the remainder ofthe AUD log reports. Save all log reports that occur at the same time. Thelog reports can help to reconstruct the event that caused the system togenerate the report.

578 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 579: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

To reconstruct the type of call, use the tools and templates and theinformation that the AUD395 or AUD398 sections provide. Use these tools,templates, and information to determine the problem.

The following steps are recommended when onsite personnel decidesrepeated call losses justify problem solving:

• Save all logs generated five min before and after the AUD report.

• Use the CALLID field for this report to look for associated AUD logs. Ifa feature is in effect, for example, three-way calling (3 WC), more thanone CALLID can associate with an agent.

• Look for associated TRAP and SWER logs or any other logsassociated with this report.

• Use the DISPCALL tool to capture failures and provide a formatteddump of the information for AUD395, AUD398, and AUD4XX logs. TheDISPCALL is a resident tool that formats the AUD395, AUD398, andAUD4XX blocks into a data representation. For more information aboutDISPCALL, Display Call (DISPCALL) User Guide, TAM-1001-003.

• When you cannot localize and correct the problem, gather the availableinformation about the call in question. For additional help, contact thenext level of technical support.

AttributesAttribute Value

Severity Warning

FormatAUD406 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid

hhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhh...

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock

CALLID Symbolic text Variable Identifies call process affected. SeeTable I.

hhhh... 0000 to FFFF Variable Indicates TOPSRU extension blockdata

Active message exampleAUD406 APR01 12:00:00 2112 INFO EXT DUMP 950289 (WORDS:

AUD406 579

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 580: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FFFF FFFF 3420 0000 0000 0000 0000 0C07 3200 0 - 8

8000 AAAA AAAA 85AA AAAA AAAA AAAA AAAA 1082 9 - 17

1806 0D48 0000 0000 00C2 8000 1205 0100 8080 18 - 26

0000 0E00 0000 03E7 AAAA AAAA AAAA AAAA 0AA 27 - 35

AAAA 40AA AAAA AAAA 0000 FFFF AAAA 0000 0000 36 - 44

8000 0000 0000 8080 8080 0000 5721 3699 2111 45 - 53

FFFF FFFF 3420 0000 0000 0000 0000 0C07 3200 54 - 62

8000 AAAA AAAA 85AA AAAA AAAA AAAA 0AAA 1082 63 - 71

1806 0D48 0000 0000 00C2 8000 1205 0100 8080 72 - 80

0000 0E00 0000 03E7 AAAA AAAA AAAA AAAA 80AA 81 - 89

AAAA 40AA AAAA AAAA 0000 FFFF AAAA 0000 0000 90 - 98

8000 0000 0000 8080 8080 0000 5721 3699 2111 99 - 107

AAAA 40AA AAAA AAAA 0000 FFFF AAAA 0000 0000 108 - 116

8000 0000 0000 8080 8080 0000 5721 3699 2111 117 - 125

0D48 0C07 03E7 1806 00C2 0000 0000 0000 0000 126 - 134

8000 0000 0000 8080 8080 0000 0000 0AAA 80AA 135 - 144

0D48 0000 AAAA 0000 00C2 145 - 149)

Clear message examplen/a

Associated OM registers

AUD407The Audit (AUD) subsystem generates the 20-word AUD407 log report.The AUD subsystem generates the AUD407 log when a data dump for athree-way calling (3WC) extension block occurs.

580 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 581: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Extension blocks provide additional data space for a call condense block(CCB). The CCB stores enough data to describe a basic call. The AUDsubsystem generates the AUD407 log when a call linked to a 3WCextension block terminates. The AUD generates the AUD407 log when thesubsystem finds a 3WC extension block that is not defined.

If the AUD subsystem detects a problem, the subsystem prints anAUDT102 report. If a call process stops without warning, the AUD prints anAUDT398 or AUD399 report.

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

Remedial actionThe AUD407 log reports indicate a clean up of call processing resourcesthat was abnormal. This clean up does not always affect service to the enduser. Repeated AUD4XX or AUD5XX log reports can indicate a translationerror or a software problem.

The AUD395 or AUD398 log reports normally print with AUD4XX andAUD5XX reports. The AUD395 and AUD398 log reports detail informationcommon to all call processes. When the features are activated against acall process, the additional information for a given feature requires storage.

Extension (EXT) blocks store additional information when the subsystemactivates features against a call. Each EXT block has a template for storeddata. The AUD4XX and AUD5XX log reports are hexadecimal models forEXT block data. The AUD4XX and AUD5XX log reports form theremainder of the AUD log reports.

It is important to save all log reports that occur at the same time. The logreports identify the event that caused the system to generate the report.

Identify the type of call and determine the source of the problem on thecall. Use the information in the AUD395 or AUD398 sections and thetemplates and tools available. Follow these steps when operating companypersonnel decide that repeated call deaths require problem solving:

• Save all logs that generated five minutes before and after the AUD logreport.

• Use the CALLID field of the AUD log report to search for other AUDreports. If another feature, like three-way calling (3WC), is in effect, themore than one CALLID can associate with the agent.

• Look for other TRAP and software error (SWER) logs or any logs thatrelate to this report.

AUD407 581

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 582: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• Use the DISPCALL tool to capture failures that follow. The DISPCALLtool provides a formatted dump of the information for AUD395,AUD398, and AUD4XX logs. The DISPCALL is a resident tool thatformats the AUD395, AUD398 and AUD4XX blocks to a data model.For more information about DISPCALL, refer to Display Call(DISPCALL) User Guide, TAM-1001-003.

• If you cannot localize and correct the problem, save all informationabout the call in question. For additional help, contact the next level oftechnical support.

AttributesAttribute Value

Severity Warning

FormatAUD407 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid(WORDS:

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh0 - 9

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh10 - 19)

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock.

callid Symbolic text Variable Identifies call process affected.

hhhh... 0000 - FFFF Variable Provides 20 words of data from 3WCextension block.

Active message exampleAUD407 APR01 12:00:00 2112 INFO EXT DUMP 375920 (WORDS:

FFFF FFFF 1D16 4000 0271 FDF4 E003 E000 FDF0 0 - 9

E000 004A 1E00 9003 2030 1C13 FCFD FDFD FDFD 10 - 19)

Clear message examplen/a

582 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 583: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AUD408The Audit (AUD) subsystem generates log report AUD408 when a datadump for an ANNEXTFC extension block occurs. Extension blocks provideadditional data space for a call condense block (CCB). The CCB storesonly enough data to describe a basic call. If the AUD subsystem detects aproblem, the CCB prints an AUDT102 log report. The AUD prints anAUDT398 or AUD399 report if a call process stops without warning.

Remedial actionThe AUD log reports indicate that the clean up of the call processingresources was not normal. This clean up does not always affect service tothe end user. Repeated AUD4XX or AUD5XX log reports indicate atranslation error or a software problem.

The AUD395 and AUD398 reports normally print with AUD4XX or AUD5XXlog reports. The AUD395 and AUD398 reports detail information commonto all call processes. When the features are activated against a callprocess, information on the additional features requires storage.

Extension (EXT) blocks store additional information when the subsystemactivates features against a call. Each EXT block has a template for storeddata. The AUD4XX and AUD5XX log reports are hexadecimal models forEXT block data. The AUD4XX and AUD5XX log reports form theremainder of the AUD log reports.

It is important to save all log reports that occur at the same approximatetime. The log reports identify the event that caused the system to generatethe report.

Identify the type of call and determine the source of the problem on thecall. Use the information in the AUD395 or AUD398 sections and thetemplates and tools available. Follow these steps when operating companypersonnel decide that repeated call deaths require problem solving:

• Save all logs generated five minutes before the AUD log report and fiveminutes after the AUD log report.

• Use the CALLID field of the AUD log report to search for other AUDreports. If another feature, like three-way calling (3WC), is in effect,more than one CALLID associates with an agent.

• Look for other TRAP and software error (SWER) logs or any logs thatrelate to this report.

AUD408 583

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 584: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• Use the DISPCALL tool to capture failures that follow. The DISPCALLtool provides a formatted dump of the information for AUD395,AUD398, and AUD4XX logs. DISPCALL is a resident tool that formatsthe AUD395, AUD398, and AUD4XX blocks to a data model. For moreinformation about DISPCALL, refer to Display Call (DISPCALL) UserGuide, TAM-1001-003.

• If you cannot localize and correct the problem, save all informationabout the call in question. For additional help, contact the next level oftechnical support.

AttributesAttribute Value

Severity Warning

Format1.AUD408 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid

hhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhh

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock

callid Symbolic text Variable Identifies call process affected

hhhh... 0000 - FFFF Variable Provides 8 words of data fromANNEXTFC extension block

Active message example1.4001000000000000000004006D4D0A00

Clear message examplen/a

Associated OM registers

AUD409The Audit (AUD) subsystem log report AUD409. The subsystem generatesthis 20-word report when a data dump for a Call Forward (CFW) extensionblock occurs.

584 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 585: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Plain ordinary telephone services (POTS) and Meridian Digital Centrex(MDC) call forward features use this extension block. Extension blocksprovide additional data space for a call condense block (CCB). The CCBstores the least possible amount of data that describes a basic call.

If the audit detects a problem, like a call error or TRAP, the systemassociates AUDT102 with the AUD report. The system associates the AUDlog report with an AUDT398 or AUD399 report if the call process stopswithout a warning.

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

Remedial actionReports AUD4XX and AUD5XX reports normally have an associatedAUD395 or AUD398 log report. The AUD395 and AUD398 reports containinformation common to all call processes. When features activate againstthe call process the system must store additional information for aspecified feature.

Storage areas for additional information are extension (EXT) blocks.Specified templates for stored data are present in all EXT blocks. TheAUD4XX and AUD5XX log reports are hexadecimal representations forEXT data blocks. The AUD4XX and AUD5XX log reports are the remainderof the AUD log reports.

It is important to save all log reports that occur around the same time. Youcan discover events that cause the system to generate the log reports fromlogs that occur around the same approximate time.

Use the information in the AUD395 or AUD398 sections and the templatesand tools to discover the type of call. The templates and tools can help todetermine the problem encountered.

Take the following five-steps when on-site personnel think that repeatedcall deaths require problem solving.

• Save all logs generated in the five minutes before the AUD log reportand for five minutes after the report.

• Look for other associated AUD reports. Use the CALLID fieldassociated with this report. An agent can link to more than one CALLIDif a feature is in progress.

• Look for associated TRAP and software error (SWER) logs or anyother logs associated with this report.

AUD409 585

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 586: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• Use the DISPCALL tool to capture failures that follow. The DISPCALLtool provides a formatted dump of information for AUD395, AUD398,and AUD4XX logs. The DISPCALL is a resident tool that formats theAUD395, AUD398 and AUD4XX blocks into a data image. For moreinformation about DISPCALL, refer to Display Call (DISPCALL) UserGuide, TAM-1001-003.

• If you cannot localize and correct the problem, gather information aboutthe call in question. Save this information and contact the next level ofsupport for assistance.

AttributesAttribute Value

Severity Warning

FormatAUD409 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid (WORDS:

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh 0-9

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh 10-19)

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates a data dump for extensionblock

callid Symbolic text Variable Identifies call process affected

hhhh... 0000-FFFF Variable Provides 20 words of data from CFWextension block

Active message exampleAUD409 APR01 12:00:00 2112 INFO EXT DUMP 100661 (WORDS:

81FA 7E00 12C0 4001 3C30 10FF 0000 0000 0000 0 - 9

0000 0000 0000 0000 FDF8 FDF8 FDF8 FDF8 FDF8 10 - 19)

Clear message examplen/a

586 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 587: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

AUD410The Audit (AUD) subsystem log report AUD410. The subsystem generatesAUD410 at a data dump. The subsystem generates AUD410 for a Circuit-Switched Digital Data Service PREM (CSDDSPREM) extension block.

Extension blocks provide additional data space for a Call Condense Block(CCB). The CCB stores the least possible data necessary to describe abasic call.

If the audit detects a problem, the AUD410 report associates with anAUD102 report. If the call process stops without a warning, AUD410associates with an AUDT399 report. The AUD410 report can associatewith an AUD398 report.

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

Remedial actionThe AUD log report indicates that call processing resources were cleanedin a method that was not normal. This problem does not always affectservice to the end user. Repeated AUD4XX or AUD5XX log reports canindicate a translation problem or a software problem.

The AUD4XX and AUD5XX reports normally associate with the AUD395 orAUD398 log reports. The AUD395 and AUD398 reports detail informationcommon to all call processes.

When features activate against a call process, the system must storeadditional information associated with a feature.

Storage areas for additional information are extension (EXT) blocks. EachEXT block has an exact template for stored data. The AUD4XX andAUD5XX log reports are hexadecimal representations for EXT block data.The AUD4XX and AUD5XX log reports are the remainder of the AUD logreports.

It is important to save all log reports that occur around the same time. Youcan discover events that cause the system to generate the log reports fromlog reports that occur around the same time.

Use the information in the AUD395 or AUD398 sections and the templatesand tools provided to discover the type of call. Use the AUD395 orAUD398 sections and the templates and tools provided to determine theproblem.

AUD410 587

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 588: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Take the following five steps when on-site personnel think that repeatedcall deaths require problem solving.

• Save all logs generated during the five minutes before the AUD logreport and for five minutes after this report.

• Use the CALLID for this report field to look for other associated AUDreports. An agent can link with more than one CALLID if a feature is inprogress.

• Look for associated TRAP and software error (SWER) logs or anyother logs to which this report associates.

• Use the DISPCALL tool to capture failures that follow. The DIPSCALLtool provides a formatted dump of information for AUD395, AUD398,and AUD4XX logs. The DISPCALL is a resident tool that formats theAUD395, AUD398, and AUD4XX blocks into a data image. For moreinformation about DISPCALL, refer to Display Call (DISPCALL) UserGuide, TAM-1001-003.

• If you can not localize and correct the problem, gather informationabout the call in question. When you have the information, contact thenext level of support for assistance.

AttributesAttribute Value

Severity Warning

FormatAUD410 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid (WORDS

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock

callid Symbolic text Variable Identifies call process affected.

hhhh 0000-FFFF Variable Provides eight words of data fromCSDDS EXTENSION BLOCK

Active message exampleAUD410 APR01 12:00:00 2112 INFO EXT DUMP 100661 (WORDS

045A 0042 0800 03CB 0000 0000 0000 0000 0->8)

588 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 589: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

AUD411The Audit (AUD) subsystem generates this report when a data dump for aROTL_PRIMING_EXTFC extension block occurs. Extension blocks areused to provide additional data space for a call condense block (CCB). TheCCB stores the least data to describe a basic call.

If the Audit detects a problem the system associates this report with anAUDT102 report. If the call process stops without warning the systemassociates this report with an AUD398 or AUDT399 report.

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

Remedial actionThe AUD log report indicates that call processing resources were cleanedup in a not normal method. This problem is not always service affecting tothe end user. But, repeated AUD4XX or AUD5XX log reports can indicatea translation problem or a software problem.

Under most conditions, AUD4XX and AUD5XX reports will have anassociated AUD395 or AUD398 log report. The AUD395 and AUD398reports detail information common to all call processes. When features areactivated against a call process, additional information associated with afeature must be stored.

These areas are called extension (EXT) blocks. Each EXT block has anexact template for stored data. The AUD4XX and AUD5XX log reports arehexadecimal representations for EXT block data. The AUD4XX andAUD5XX log reports comprise the remainder of the AUD log reports.

It is important to save all log reports that occur at the same approximatetime. Logs that occur at the same time can aid in reconstructing the eventthat generated the report.

Use the information provided in the AUD395 or AUD398 sections and thetemplates and tools provided to discover the type of call. Use the AUD395or AUD398 sections and the templates and tools provided to determine thetrouble encountered.

AUD411 589

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 590: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The following five-steps are recommended when on-site personnel thinkthat repeated call deaths warrant troubleshooting.

• Save all logs generated during the five minutes previous to the AUD logreport and for five minutes following this report.

• Look for other associated AUD reports by using the CALLID fieldassociated with this report. An agent can link with more than oneCALLID if a feature, three-way calling for example, is in effect.

• Look for associated TRAP and software error (SWER) logs or anyother logs to which this report can associate.

• Use the DISPCALL tool to capture failures that follow and provide aformatted dump of information for AUD395, AUD398, and AUD4XXlogs. DISPCALL is a resident tool that formats the AUD395, AUD398,and AUD4XX blocks into a data image. For more information aboutDISPCALL, refer to Display Call (DISPCALL) User Guide,TAM-1001-003.

• If you can not localize and correct the problem, gather informationabout the call in question. When you have the information contact thenext level of technical support for help.

AttributesAttribute Value

Severity Warning

FormatAUD411 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid (WORDS

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh 0->9

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh 10->19)

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed This field Indicates data dump forextension block

callid Symbolic text Variable This field Identifies call processaffected

hhhh 0000-FFFF Variable This field provides 20 words of datafrom ROTL_PRIMING_EXTFCextension block. The following figureidentifies information in these fields.

590 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 591: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleAUD411 APR01 12:00:00 2112 INFO EXT DUMP 419104 (WORDS

1001 FFFF FFFF FFFF FFFF FFFF FFFF FFFF FFFF 0->9

FFFF FFFF 8000 0000 0000 FFFF FFFF FFFF FFFF 10->19)

Clear message examplen/a

Associated OM registers

AUD412The Audit (AUD) subsystem log report AUD412. The subsystem generatesAUD412 when a data dump for a CALL WAITING DATA extension blockoccurs. Extension blocks provide additional data space for a CallCondense Block (CCB). A CCB stores the least possible amount of dataneeded to describe a basic call. If the Audit detects a problem, this reportassociates with an AUDT102 report. This report associates with anAUDT399 report if a call process stops without a warning. This report canassociate with an AUD398 report.

The following diagram shows the field positions within words 0 and 1:

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

Remedial actionThe AUD log report shows all processing resources were cleaned in amethod that was not normal. This problem does not affect service to theend user. Repeated AUD4XX or AUD5XX log reports can show translationor software problems.

The AUD4XX and AUD5XX reports normally have an associated AUD395or AUD398 log report. The AUD395 and AUD398 reports containinformation common to all call processes. When a feature activates againstthe call process the system must store additional information for a feature.

Storage areas for additional information are extension (EXT) blocks. AllEXT blocks contain specified templates for stored data. The AUD4XX andAUD5XX log reports are hexadecimal representations for EXT data blocks.The AUD4XX and AUD5XX log reports are the remainder of the AUD logreports.

AUD412 591

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 592: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

It is important to save all log reports that occur around the sameapproximate time. Logs that occur around the same time can provide thereason the system generated the log.

Use the information in the AUD395 or AUD398 sections and the templatesand tools provided to discover the type of call. The templates and toolshelp determine the problem. Take the following five steps when on-sitepersonnel think that repeated call deaths require problem solving.

• Save all logs generated during the five minutes before the AUD logreport and for five minutes after this report.

• Use the CALLID field associated with this report to look for otherassociated AUD reports. An agent can link to more than one CALLID ifa feature is in effect.

• Look for associated TRAP and software error (SWER) logs or anyother logs associated with this report.

• Use the DISPCALL tool to capture failures that follow. Provide aformatted dump of information for AUD395, AUD398, and AUD4XXlogs. The DISPCALL is a resident tool that formats the AUD395,AUD398 and AUD4XX blocks into a data image. For more informationabout DISPCALL, refer to Display Call (DISPCALL) User Guide,TAM-1001-003.

• If you can not localize and correct the problem, gather informationabout the call in question. Save this information and contact the nextlevel of support for assistance.

AttributesAttribute Value

Severity Warning

FormatAUD412 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid (WORDS)

hhhhhhhh

592 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 593: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed This field indicates data dump forextension block

callid Symbolic text Variable This field identifies call processaffected

hhhh... 0000 - FFFF Variable This field identifies CALL WAITINGDATA extension block data

Active message exampleAUD412 APR01 12:00:00 2112 INFO EXT DUMP 386203 (WORDS

F32A FFFF 3420 0000 0000 B012 0000 0C07 3200 0 - 8

8000 AF57 AAAA 85AA F324 AAAA 0808 9 - 15)

Clear message examplen/a

Associated OM registers

AUD413The audit (AUD) subsystem generates AUD413 when a data dump occursfor a CMATOPS_RU extension block. The CAMATOPS_RU stands forcentralized automatic message accounting TOPS system recording unit.

Call condense blocks (CCB) store enough space to describe a basic call.Extension blocks provide additional space for a CCB. When the AUDsubsystem detects a problem, the subsystem associates the AUD413report with an AUD102 report. The audit associates the report with anAUDT399 or an AUD398 when the call process stops without warning.

The field positions in words 0, 1, 2 and 3 appear in the following diagram:

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

Remedial actionContact the next level of maintenance.

AUD413 593

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 594: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatAUD413 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid (WORDS)

hhhhhhhh

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock

callid Symbolic text Variable Identifies call process affected. Referto Table I.

hhhh... 0000 - FFFF Variable Identifies CAMATOPS_RU extensionblock data

Active message exampleAUD413 APR01 12:00:00 2112 INFO EXT DUMP 950289 (WORDS

FFFF FFFF 3420 0000 0000 0000 0C07 3200

0-8

8000 AAAA AAAA 85AA AAAA AAAA AAAA 1082

9-17

1806 0D48 0000 0000 00C2 1205 0100

8080 18-26

0000 0E00 0000 03E7 AAAA AAAA AAAA 80AA

27-35

AAAA 40AA AAAA 0000 FFFF AAAA 0000

0000 36-44

8000 0000 0000 8080 0000 5721 3699

2111 45-53

594 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 595: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FFFF FFFF 3420 0000 0000 0000 0C07

3200 54-62

8000 AAAA AAAA 85AA AAAA AAAA 0AAA

1082 63-71

1806 0D48 0000 00C2 8000 1205 0100

8080 72-80

0000 0E00 0000 03E7 AAAA AAAA AAAA

0000 81-88

0000 0D00 0000 04F8 0000 8080 80A4

0000 89-98

AAAA 0000 07D5 0000 99-103)

Clear message examplen/a

Associated OM registers

AUD414The Audit (AUD) subsystem generates this report when a data dump for anIBN_CALLQ_EXT extension block occurs. Extension blocks provideadditional data space for a call condense block (CCB). A CCB stores onlyenough data to describe a basic call. The AUD414 report associates withan AUDT102 report if the audit detects a problem. The AUD414 reportassociates with an AUD398 or AUDT399 report if the call process stopswithout a warning.

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

Remedial actionThe AUD log reports indicate that the clean up of call processing resourceswas abnormal. This clean-up does not always affect service to the enduser. Repeated AUD4XX or AUD5XX log reports can indicate a translationerror or a software problem.

AUD414 595

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 596: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AUD4XX and AUD5XX reports normally have an associated AUD395 orAUD398 log report. The AUD395 and AUD398 reports detail informationcommon to all call processes. When the features are activated against acall process, additional information for that feature requires storage. Thesestorage areas are extension (EXT) blocks.

Each EXT block has a specified template for stored data. The AUD4XXand AUD5XX log reports are hexadecimal representations for EXT blockdata. The AUD4XX and AUD5XX log reports form the remainder of theAUD log reports. You must save all log reports that occur at the sameapproximate time. You can use these logs to construct the event again thatcaused the system to generate the report.

Use the information that the AUD395 or AUD398 sections provide, and thetemplates and tools available. Construct the type of call and determine theproblem encountered. Follow these steps when operating companypersonnel decide repeated call deaths require problem solving:

• Save all logs that the system generated during the five minutes beforeand after the AUD log report.

• Use the CALLID field that associates with this report to search forassociated AUD reports. More than one CALLID can associate with anagent if a feature is in effect.

• Look for associated TRAP and software error (SWER) logs or anyother logs that associate with this report.

• Use the DISPCALL tool to capture additional failures. This DISPCALLtool provides a formatted dump of the information for AUD395,AUD398, and AUD4XX logs. DISPCALL is a resident tool that formatsthe AUD395, AUD398, and AUD4XX blocks into a data representation.For more information about DISPCALL, refer to Display Call(DISPCALL) User Guide, TAM-1001-003.

• If you cannot localize and correct the problem, save all availableinformation about the call in question. For additional help, contact thenext level of technical support.

AttributesAttribute Value

Severity Warning

FormatAUD414 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid (WORDS:

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

596 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 597: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock

callid Symbolic text Variable Identifies call process affected

hhhh... 0000 to FFFF Variable Identifies IBN_CALLQ_EXT extensionblock data

Active message exampleAUD414 APR01 12:00:00 2112 INFO EXT DUMP 486035 (WORDS:

0801 0000 0000 0000 0000 8080 8080 8080 0-8

4080 8080 8080 8080 8080 0080 0000 0101 9-17

0000 0000 8080 533B 0000 18-25)

Clear message examplen/a

Associated OM registers

AUD416The Audit (AUD) subsystem generates AUD416 when a data dump for aStation Message Detail Recording Unit (SMDR_RECORD_UNIT)extension block occurs. Extension blocks provide additional data space forcall condense block (CCBs) and Call Data Block (CDBs). AUD416associates with an AUDT102 report if the audit detects a problem. TheAUD416 associates with an AUD398 or AUDT399 report if the call processstops without notice.

The field positions in words 0, 1, 2 and 3 appear in the following illustration:

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

Remedial actionThe AUD log reports show call processing resources were cleaned up in amanner that is not normal. This procedure does not always affect serviceto the end user. Repeated AUD4XX or AUD5XX log reports can show atranslation or software problem.

AUD416 597

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 598: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Most AUD4XX and AUD5XX reports have an associated AUD395 orAUD398 log report. The AUD395 and AUD398 reports have detailedinformation common to all call processes. When features are activatedagainst a call process, the system must store additional informationassociated with a certain feature. These areas are called extension (EXT)blocks. Each EXT block has a specified template for stored data. TheAUD4XX and AUD5XX log reports are hexadecimal representations forEXT block data. These log reports are the last of the AUD log reports.

It is important to save all log reports that occur in one period of time. Theselogs can help reconstruct the event that generated the report.

Use the information provided in the AUD395 or AUD398 sections and thetemplates and tools provided to construct the type of call again. Thisinformation determines the trouble encountered. The following nine stepsare recommended when on-site personnel decide that repeated call deathsjustify troubleshooting:

• Save all logs generated during the 5 min before to the AUD log reportand for 5 min after this report.

• Use the CALLID field associated with this report to locate otherassociated AUD reports. More than one CALLID can be associatedwith an agent if a feature is in effect. An example of this feature isthree-way calling.

• Look for associated TRAP and software error (SWER) logs or otherlogs that can be associated with this report.

• Look for AUDT102 reports if the audit detects a problem. Look forAUD398 or AUDT399 reports if the call process stops without notice.

• Examine the agent IDs (ORIG_AGENT and TERM_AGENT). Thesefields identify the calling and called agents, in this order. If more thanone AUD416 report shows the same originator and terminator, theproblem can be localized.

• Examine the call processing selector (CPSs). These fields identify thetypes of call lines. An important indicator is if several log reports show aspecified line type.

• Examine the available data to decide if the problem relates to corruptdata tables or to the code. An example of a corrupt data table istranslation. Contact maintenance personnel if the code is suspect.

• Use the DISPCALL tool to capture other failures and provide aformatted dump of the information for AUD395, AUD398, and AUD4XXlogs. The DISPCALL is a resident tool that formats the AUD395,

598 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 599: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AUD398, and AUD4XX blocks into a data representation. For moreinformation about DISPCALL, refer to Display Call (DISPCALL) UserGuide, TAM-1001-003.

• If you cannot localize and correct the problem, gather the mostinformation possible about the call in question. Contact the next level ofsupport.

AttributesAttribute Value

Severity Warning

FormatAUD416 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid (WORDS:

hhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhh...

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock

callid Symbolic text Variable Identifies call process affected

hhhh... 0000 - FFFF Variable Provides the data in this extensionblock. Refer to the introduction sectionof this document to interpret thisfigure.

Active message exampleAUD416 APR01 12:00:00 2112 INFO EXT DUMP 486035

(WORDS:0801 0000 0000 0000 0000 8080 8080 8080 0-8

4080 8080 8080 8080 8080 0080 0000 0000 9-17

0000 0000 8080 533B 0F00 0801 0000 0000 18-26

0000 8080 8080 8080 8080 4080 8080 8080 27-35

8080 0080 0000 0000 0000 0000 0000 9E12 36-44

B074 F912 0480 A8E1 8080 C3F0 AE4F 72BA 45-53

0F00 0480 533A 8080 8080 0000 8080 54-61)

AUD416 599

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 600: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

AUD417The Audit (AUD) subsystem report AUD417. The subsystem generatesAUD417 when a data dump for an ALTADDR_EXT_FC extension blockoccurs. Extension blocks provide additional data space for call condenseblock (CCB) and call data block (CDB). A CDB only stores enough data todescribe a basic call. If the audit detects a problem, this report associateswith an AUDT102 report. If the call process stops without a warning, thisreport associates with an AUD398 or AUD399 report.

The following diagram shows the field positions in words 0 and 1:

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

Remedial actionThe AUD log reports indicate a clean up of call processing resources thatwas not normal. This clean up does not always affect service to the enduser. Repeated AUD4XX or AUD5XX log reports can indicate a translationor software problem.

The AUD4XX and AUD5XX reports normally have an associated AUD395or AUD398 log report. The AUD395 and AUD398 reports detail informationcommon to all call processes. When the user activates features against acall process, the additional information for a given feature must be stored.These areas are called extension (EXT) blocks. Each EXT block has atemplate for stored data. The AUD4XX and AUD5XX log reports arehexadecimal representations for EXT block data. These reports for theremainder of the AUD log reports. Save all log reports that occur at thesame time. The log reports can help to reconstruct the event that causedthe system to generate the report.

To reconstruct the type of call, use the tools and templates and theinformation, which the AUD395 or AUD398 sections provide. Use thesetools, templates and information to determine the problem encountered.

600 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 601: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The following steps are recommended when onsite personnel deciderepeated call losses justify problem solving.

• Save all logs generated 5 min before and after the AUD report.

• Use the callid field for this report to look for associated AUD logs. If afeature is in effect, for example, three-way calling (3WC), more thanone callid can associate with an agent.

• Look for associated TRAP and SWER logs or other logs associatedwith this report.

• Use the DISPCALL tool to capture failures and provide a formatteddump of information for AUD395, AUD398, and some AUD4XX logs.The DISPCALL is a resident tool that formats the AUD395, AUD398,and some AUD4XX blocks into a data representation. For moreinformation about DISPCALL, Display Call (DISPCALL) User Guide,refer to TAM-1001-003.

• When you cannot localize and correct the problem, gather all availableinformation about the call in question. For additional help, contact thenext level of technical support.

AttributesAttribute Value

Severity Warning

FormatAUD417 mmdd hh:mm:ss ssdd INFO EXT DUMP callid

hhhh hhhh hhhh hhhh

Selected field descriptionsField Value Fixed or

VariableDescription

EXT DUMP Constant Fixed Indicates data dump for extensionblock.

call identification Symbolic text Variable Identifies call process affected.

hhhh... 0000 - FFFF Variable Identifies ALTADDR_EXT_FCextension block data.

Active message exampleAUD417 APR01 12:00:00 2112 INFO EXT DUMP 375319

(WORDS: 0043 0D3A 0000 35E3

0 - 3

AUD417 601

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 602: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

AUD418The Audit (AUD) subsystem generates the AUD418 log report when a datadump occurs. The data dump occurs for an automatic servicing observingrecording unit (ASO_RECORD_UNIT) extension block. Extension blocksprovide additional data space for a call condense block (CCB). A CCBstores the necessary data to describe a basic call. If the audit detects aproblem, the subsystem associates this report with an AUDT102 report. Ifthe call process stops without a warning, the subsystem associates thisreport with an AUD398 or AUDT399 report.

"For information about interpreting the hex dump in the log report, pleaserefer to NN10275-909V19."

Remedial actionThe AUD log reports indicate call processing resources were cleaned upby an abnormal method. This clean up does not always affect service tothe end user.

Repeated AUD4XX or AUD5XX log reports can indicate a translation erroror a software problem.

AUD4XX and AUD5XX reports normally have an associated AUD395 orAUD398 log report. The AUD395 and AUD398 reports detail informationcommon to all call processes. When the features are activated against acall process, the subsystem must store additional information thatassociates with a particular feature. These storage areas are calledextension (EXT) blocks. Each EXT block has a specified template forstored data. The AUD4XX and AUD5XX log reports are hexadecimalrepresentations for EXT block data. The AUD4XX and AUD5XX log reportsmake up the rest of the AUD log reports.

You must save all log reports that occur at the same approximate time.You can use these log reports to reconstruct the event that caused thesystem to generate the report.

602 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 603: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Use the information that the AUD395 or AUD398 sections provide, and thetemplates and tools available. Construct the type of call again anddetermine the problems that occur. The following five steps arerecommended when on-site personnel decide repeated call deaths warrantproblem solving:

• Save all logs generated during the five minutes before the AUD logreport and for five minutes after this report.

• To search for other associated AUD reports use the CALLID fieldassociated with this report. The subsystem can associate more thanone CALLID with an agent if a feature is in effect. The subsystem canassociate more than one CALLID field if three-way calling is in effect.

• Look for associated TRAP and software error (SWER) logs or anyother logs that associate with this report.

• Use the DISPCALL tool to capture additional failures. The DISPCALLtool provides a formatted dump of the information for AUD395,AUD398, and AUD4XX logs. DISPCALL is a resident tool that formatsthe AUD395, AUD398, and AUD4XX blocks to a data representation.For more information about DISPCALL, refer to Display Call(DISPCALL) User Guide, TAM-1001-003.

• If you cannot localize and correct the problem, save information aboutthe call in question. Contact the next level of technical support for help.

AttributesAttribute Value

Severity Warning

FormatAUD418 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid (WORDS:

hhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhh...

Selected field descriptionsField Value Fixed or

VariableDescription

hhhh... 0000 - FFFF Variable Identifies ASO_RECORD_UNITextension block data

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock

callid Symbolic text Variable Identifies call process affected

Active message exampleAUD418 APR01 12:00:00 2112 INFO EXT DUMP 125840 (WORDS:

AUD418 603

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 604: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

2001 8000 0000 0000 0000 0000 8080 8080 8080 0 - 8

8080 8080 8080 8080 8080 8080 8080 0000 0000 9 - 17

A000 0000 0000 8000 2D6D 18 - 22

Clear message examplen/a

Associated OM registers

AUD419The Audit (AUD) subsystem generates this report when a data dump for aCFD_EXT_FC extension block occurs. Extension blocks provide additionaldata space for a call condense block (CCB). A CCB stores the necessarydata to describe a basic call. If the audit detects a problem, the auditassociates this report with an AUDT102 report. If the call process stopswithout a warning, associate this report with an AUD398 or AUD399 report.

Remedial actionThe AUD log reports show call processing resources were cleaned up byan abnormal method. This clean up does not always affect service to theend user. Repeated AUD4XX or AUD5XX log reports can indicate atranslation error or a software problem.

AUD4XX and AUD5XX reports normally have an associated AUD395 orAUD398 log report. The AUD395 and AUD398 reports detail informationcommon to all call processes. When the features are activated against acall process, the system must store additional information associated withthat feature. These storage areas are called extension (EXT) blocks. EachEXT block has a specified template for stored data. The AUD4XX andAUD5XX log reports are hexadecimal representations for EXT block data.The remainder of the AUD log reports include the AUD4XX and AUD5XXlog reports.

You must save all log reports that occur at the same approximate time.You can use these log reports to construct the event again that caused thesystem to generate the report.

604 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 605: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Use the information that the AUD395 or AUD398 sections provide and thetemplates and tools provided. Construct the type of call again anddetermine the problem encountered. Follow these steps when operatingcompany personnel decide repeated call deaths require problem solving:

• Save all logs generated during the five minutes before the AUD logreport and for five minutes after this report.

• Use the CALLID field associated with this report to search forassociated AUD reports. More than one CALLID field can associatewith an agent if a feature is in effect.

• Look for associated TRAP and software error (SWER) logs or anyother logs that associate with this report.

• Use the DISPCALL tool to capture additional failures. The DISPCALLtool provides a formatted dump of the information for AUD395,AUD398, and AUD4XX logs. DISPCALL is a resident tool that formatsthe AUD395, AUD398, and AUD4XX blocks to a data representation.For more information about DISPCALL, refer to Display Call(DISPCALL) User Guide, TAM-1001-003.

• If you cannot localize and correct the problem, save all availableinformation about the call in question. Contact the next level of support.

AttributesAttribute Value

Severity Warning

Format.AUD419 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid

hhhhhhhhhhhhhhhhhhhh

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock

callid Symbolic text Variable Identifies call process affected

hhhh... 0000 - FFFF Variable Provides 5 words of data fromCFD_EXT_FC extension block

Active message exampleAUD419 APR01 12:00:00 2112 INFO EXT DUMP 375914

0026A86D000050E4A360

AUD419 605

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 606: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

AUD420The Audit (AUD) subsystem generates log report AUD420 when a datadump occurs for an AVDSA_RECORD_UNIT extension block. Extensionblocks provide additional data space for a call condense block (CCB). ACCB stores only enough data to describe a basic call. This reportassociates with log report AUDT102 if the audit detects a problem. Logreport AUD420 associates with AUD398 or AUDT399 if the call processstops without warning.

Remedial actionThe AUD log reports indicate that the system used an abnormal method toclean up call processing resources. This condition does not always affectservice to the end user. Repeated AUD4XX or AUD5XX log reports canindicate a translation problem or a software problem.

Log reports AUD4XX and AUD5XX normally have an associated AUD395or AUD398 log report. The AUD395 and AUD398 reports provideinformation common to all call processes. When the system activatesfeatures against a call process, the system must store additionalinformation associated with a specified feature. The storage areas areextension (EXT) blocks. Each EXT block has a specified template forstored data. The AUD4XX and AUD5XX log reports are hexadecimalmodels for EXT block data. These log reports compose the AUD logreports that remain.

Save all log reports that occur at the same approximate time. Thesereports can help reconstruct the event that caused the system to generatethe report.

Use the following to reconstruct the type of call and determine the troublethat occurred:

• information in the AUD395 or AUD398 sections

• provided templates

• provided tools

606 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 607: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Follow the following five steps when operating company personnel deciderepeated call deaths require troubleshooting:

• Save all logs that the subsystem generated 5 min before and after theAUD log report.

• Use the CALLID field for this report to search for other associated AUDreports. A minimum of two CALLID can associate with an agent if afeature is in effect. Three-way calling is an example of a feature.

• Look for associated TRAP and software error (SWER) logs or otherlogs that can associate with this report.

• Use the DISPCALL tool to capture the failures that follow. Use theDISPCALL tool to provide a formatted dump of the information forAUD395, AUD398, and AUD4XX logs. The DISPCALL is a residenttool that formats the AUD395, AUD398 and AUD4XX blocks into a datamodel. For additional information about DISPCALL, refer to DisplayCall (DISPCALL) User Guide, TAM-1001-003.

• If you cannot localize and correct the problem, collect the mostinformation as possible about the call. Contact the next level of support.

AttributesAttribute Value

Severity Warning

FormatAUD420 mmmdd hh:mm:ss ssdd INFO EXT DUMP callid (WORDS:

hhhh hhhh hhhh hhhh hhhh hhhh hhhh hhhh

Selected field descriptionsField Value Fixed or

VariableDescription

INFO EXT DUMP Constant Fixed Indicates data dump for extensionblock

callid Symbolic text Variable Identifies the affected call process

hhhh... 0000 - FFFF Variable Provides data fromAVDSA_RECORD_UNIT extensionblock

Active message exampleAUD420 APR01 12:00:00 2112 INFO EXT DUMP 486035 (WORDS:

0801 0000 0000 0000 0000 8080 8080 8080 0-8

AUD420 607

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 608: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

4080 8080 8080 8080 8080 0080 0000 0000 9-17

0000 0000 8080 533B 0F00 0801 0000 0000 18-26

0000 8080 8080 8080 8080 4080 8080 8080 27-35

8080 0080 0000 0000 0000 0000 2801 8080 36-44

0801 0000 0000 0000 0000 8080 8080 8080 45-53

4080 8080 8080 8080 8080 0080 0000 0000 54-62

0000 0000 8080 533B 0F00 0801 0000 0000 63-71

0000 8080 8080 8080 8080 4080 8080 8080 72-80

8080 0080 0000 0000 0000 0000 2801 8080 81-89

8080 0080 0000 0000 0000 0000 0000 8080 90-98

0801 0000 0000 0000 0000 8080 8080 8080 99-107

4080 8080 8080 8080 8080 0080 0000 0000 108-116

0000 0000 8080 533B 0F00 0801 0000 0000 117-125

0000 8080 8080 8080 8080 4080 8080 8080 126-130

8080 0080 0000 0000 0000 0000 2801 8080 131-133

8080 0080 0000 0000 0000 0000 0000 0000 134-146

8080 0080 0000 147-151)

Associated OM registers

608 DMS_ACDtoAUD alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 10

NN10275-909v10 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 609: NN10275 909v10 12.01 CVM16 c20 Fault Management Logs Alarms Ref

C20 Converged Softswitch

Logs and Alarms Reference, Volume 10Release: CVM16 and upPublication: NN10275-909v10Document Revision: 12.01Document release date: 03 October 2011

Copyright © 2011 GENBAND. All rights reserved. Use of this documentation and its contents is subject to the terms and conditionsof the applicable end user or software license agreement, right to use notice, and all relevant copyright protections.

GENBAND, the GENBAND corporate logo and tagline, and certain of GENBAND's product and solution names are registeredtrademarks of GENBAND and its affiliates.

While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writingGENBAND AND/OR ITS LICENSORS PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANYKIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to changewithout notice.

THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF GENBAND OR ITS LICENSORS AND MUST NOT BEDISCLOSED, OTHER THAN TO EMPLOYEES OF GENBAND OR CUSTOMERS WITH NEED-TO-KNOW, WITHOUT THEPRIOR WRITTEN CONSENT OF GENBAND OR ITS LICENSORS. THE INFORMATION MUST NOT BE DISCLOSED TOSUBCONTRACTORS OR REGULATORY AUTHORITIES. GENBAND MUST BE NOTIFIED OF ANY REQUEST OR ORDERFOR DISCLOSURE PRIOR TO SUCH DISCLOSURE.

Software and documentation owned by or under license with Nortel Networks included in this Release or in any documentprovided with this Release is Copyright © 2010 Nortel Networks or its licensors. All rights reserved. Use of this software and/ordocumentation and its contents is subject to the terms and conditions of the applicable end user or software license agreement,right to use notice, and all relevant copyright protections. The product names remain as Carrier VoIP and CS 2000 in Canada and France pending regulatory approvals for a name change.

www.genband.com