no lo leas

Download No lo leas

If you can't read please download the document

Upload: sahaquiel

Post on 24-Dec-2015

10 views

Category:

Documents


2 download

DESCRIPTION

cosogroso importante shhhh secreto iniciático masónico luciferino illuminatti

TRANSCRIPT

XBT L-1000 v4.51 File README English / FranaisCopyright (C) SCHNEIDER ELECTRIC SA 1994-2007. All rights reserved._______________________________ENGLISH_________________________________________TABLE OF CONTENTS OF THE README FILE1. General problems encountered when using the software 1.1 Management of the "page to process" in the dialogue table 1.2 Switching from protocol UNITELWAY1 to UNITELWAY 1.3 Import/Export text via a worksheet 1.4 XBTN/XBTH/XBTP/XBTE application name 1.5 XBTN page tree 1.6 Entry of command links 1.7 Protocol Sysmacway 1.8 Floating variable with PLC bounds 1.9 Incompatibility of XBTL1000 with some software (example: software VEGA) 1.10 Image of system keys 1.11 Dialoging with Quantum Unity PLCs 1.12 XBT-F/T-XBT-F : Compatibility between ModBus Plus card MBP100 and Proworx32 1.13 XBTF simulation issue when using option "Support Unity Premium" or "Support Unity Quantum" 2. Problems encountered when using Windows 2000 2.1 Alphanumeric Terminals 2.1.1 Simulation launching 2.2 Graphic terminals 2.2.1 Simulation launching 2.2.2 Display of J and T characters for TXT2 and CYR2 fonts3. Problems encountered when using Windows XP 3.1 Alphanumeric Terminals 3.1.2 Colours in the menus 3.1.3 Simulations launching 3.2 Graphic terminals 3.2.1 Colours in the menus 3.2.2 Simulations launching 3.2.3 Display of the system menu buttons 3.2.4 Transfer to a terminal 3.3 Problems common to both type of terminals 3.3.1 Unitelway driver setup, used for transfering applications 3.3.2 Installation of Unitelway driver fails4. Troubleshooting issues 4.1 Management of the "page to process" in the dialogue table (see 1.1) 4.2 Import/Export text via a worksheet (see 1.3) 4.3 Simulations launching (see 2.1.1, 2.2.1, 3.1.2, and 3.2.2) 4.4 Colours in the menus (see 3.1.1 and 3.2.1) 4.5 Buttons of the system menu (see 3.2.3) 4.6 Transfer to a terminal (see 3.2.4) 4.7 Display of J and T characters for TXT2 and CYR2 fonts (see 2.2.2) 4.8 XBTR/XBTN/XBTH/XBTP/XBTE application name (see 1.4) 4.9 XBTN page tree (see 1.5) 4.10 Entry of command links (see 1.6) 4.11 Update of system pages 4.12 Update of the Bios 4.13 Link with Unity Studio Manager 4.14 Dialoging with Quantum Unity PLCs (see 1.11) 4.15 Communication between a PLC SLC05/03 or SLC05/04 and a terminal XBTN/XBTR5. Further information6. Warnings on TXBT______________________________________________________________________________1. General problems encountered when using the software 1.1 Management of the "page to process" in the dialogue table From version XBTL1000 V3.4 , the word "page to process" in the dialogue table must be written once only so as the terminal changes page. Otherwise, the terminal will continuously change to the page already displayed (flashing) 1.2 Switching from protocol UNITELWAY1 to UNITELWAY When switching from protocol Unitelway1 to Unitelway and vice versa, the addresses of variables are lost. 1.3 Import/Export text via a worksheet When exporting/importing texts via Excel, if you replace a message by a longer one, the new message will be shortened to the size of the first message. When a text is between quotation marks, Excel doubles these quotation marks. At the time of the importation of these texts, XBT-L1000 does not recognize them. 1.4 XBTN/XBTH/XBTP/XBTE application name These characters are not authorized: (&),(+),( ),(=),([),(]),(^). 1.5 XBTN page tree The page tree of an application XBTN presents an different aspect according to the creation links order. 1.6 Entry of command links XBT-L1000 allows the configuration of more than two links in the same application page for a command terminal XBTN*(1). These links cannot be activable with the terminal. 1.7 Protocol Sysmacway The communication in Sysmacway between Magelis and the PLC variable with an adress > at 9999 doesn't run. Use only the PLC variable with an adress 9999 ne fonctionne pas. Utilisez des variables API avec des adresses