no touch loading technique
DESCRIPTION
TRANSCRIPT
![Page 1: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/1.jpg)
Cu T 380 A
No Touch Loading Technique
![Page 2: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/2.jpg)
Female Sterilisation Condoms
PillIUCD
Male Sterilisation
![Page 3: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/3.jpg)
Several problems with IUCD
Often, they are not inherent problems of IUD
Poor motivation of Client
Poor Selection of Cases Poor insertion techniquePoor infection prevention strategiesPoor post procedural counseling
Poor motivation of Client
Poor Selection of Cases Poor insertion techniquePoor infection prevention strategiesPoor post procedural counseling
Provider dependent problemsPoor training.Provider dependent problemsPoor training.
![Page 4: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/4.jpg)
Some of you may have a bad impression of Copper T
Some of you may have a bad impression of Copper T
Perforation,
Expulsion,
Failure,
Ectopic………
Don’t condemn !look at the evidence Don’t condemn !look at the evidence
It is uselessIt is useless
![Page 5: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/5.jpg)
Rate of Pregnancy With Typical Use
TC
u380
A
0%
5%
10%
15%
20%
25%
30%
TC
u380
A
Min
i Pil
l
Com
bine
dPi
ll
Mal
eC
ondo
m
Dia
phra
m
Fem
ale
Con
dom
Spe
rmic
ide
Methods
Per
cent
age
High Failure Rate ?Failure percentage of different methods with typical use
Source…Contraceptive Technology Update Series…Family Health International
![Page 6: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/6.jpg)
ESTIMATED ECTOPIC PREGNANCY AND CONTRACEPTIVES
0
1
2
3
4
5
6
7
No
Met
hod
Dia
phra
m
Con
dom
Fem
ale
Ste
rili
zati
on
OC
P
TC
u38
0A
METHOD
RA
TE
LOW ECTOPIC PREGNANCIES
Use of TCu 380 A has one of the lowest rates of ectopic pregnancies.
Source…Contraceptive Technology Update Series…Family Health International
91% less chance of developing Ectopic than control
![Page 7: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/7.jpg)
CONTINUATION RATE• IUD has one of the highest continuation
rates at first year of use
Continuation Rate of different contraception methods
80%
72% 70% 67%63%
58%
43%
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
IUD
Com
bina
tion
pill Dep
o-Pr
over
a
Perio
dic
abst
inen
ce
Mal
eco
ndom
Dia
phra
gm
Sper
mic
ides
Contraception methods
Perc
enta
ge
IUD
Combination pill
Depo-Provera
Periodic abstinence
Male condom
Diaphragm
Spermicides
Source…California Journal of Health-System Pharmacy
![Page 8: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/8.jpg)
Why the failures?Why the failures?
Poor positioning of CuTFaulty Insertion TechniquePoor positioning of CuTFaulty Insertion Technique
![Page 9: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/9.jpg)
Higher Infection rates ?Higher Infection rates ?
Poor infection prevention strategies
Providers not familiar with “No touch Technique”
Poor infection prevention strategies
Providers not familiar with “No touch Technique”
![Page 10: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/10.jpg)
Loading Copper TLoading Copper T
![Page 11: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/11.jpg)
Overlooking the “No touch technique”Overlooking the “No touch technique”
Usual Technique Usual Technique
![Page 12: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/12.jpg)
Copper T is not touched at any stage
Copper T is not touched at any stage
![Page 13: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/13.jpg)
Inspection of Copper T
Expiry Date
![Page 14: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/14.jpg)
Step 1
Open the pack at the far end
Step 1
Open the pack at the far end
![Page 15: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/15.jpg)
Holding the package with open end up, put the white solid rod into the insertion tube to almost touch the bottom of the T
Step 2
![Page 16: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/16.jpg)
Step 3
Withdraw the Copper T with insertion tube a little downwards
![Page 17: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/17.jpg)
Step 4
Place the package on the clean, hard, flat surface.
Fix the arms
Push up the tube
Insert the arms
Step 3
![Page 18: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/18.jpg)
Step 5
Adjusting blueLength gauge
![Page 19: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/19.jpg)
Step 6
![Page 20: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/20.jpg)
Step 7
It directly goes into the uteruswithout touching vaginal walls
![Page 21: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/21.jpg)
Withdrawal
Technique
Client is ready, Cervico vaginal
preparation done already
Step 8
![Page 22: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/22.jpg)
Remove the Plunger first
Step 9
If the plunger and The tube together
withdrawn
![Page 23: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/23.jpg)
Step 10Second Push
![Page 24: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/24.jpg)
Step 11
Don’t catch the tail with Artery forceps
![Page 25: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/25.jpg)
Rest for few minutes after insertionReassureReview
Referral of complicated case
![Page 26: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/26.jpg)
IUDs: Client Information and Instructions
Return to clinic immediately if you:
Experience any of the warning signs
“PAINS”
Feel the hard part of the IUD,
Expel the IUD, or
Miss a period.
![Page 27: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/27.jpg)
Post procedural Counseling
Subsequent reviewPossible discomfortMedication sosContact detailsFollow up visit
etc etc
Post procedural Counseling
Subsequent reviewPossible discomfortMedication sosContact detailsFollow up visit
etc etc
![Page 28: No touch loading technique](https://reader036.vdocuments.net/reader036/viewer/2022070303/54906f02b47959460a8b45d5/html5/thumbnails/28.jpg)
TCu RegularTCu Regular
TCu with safe load deviceTCu with safe load device