![Page 1: NORDSON CORPORATION Vista Control Guideemanuals.nordson.com/adhesives/3000V/3100v/manuals/321213c.pdf · Vista Control Guide P/N 321213C Standard or Pattern Control TC Circuit Boards](https://reader033.vdocuments.net/reader033/viewer/2022050607/5fae1d90fc341f01835aeaac/html5/thumbnails/1.jpg)
Vista™ Control Guide
Complete Control Assembly
Electrical
®
NORDSON CORPORATION
1
MembranePanel
2
Casting
Display Board
5
Control Board
4
Power Board
3Voltage Plug
Vista Control Guide P/N 321213C
Voltage Plugs Wire color227569=400/230 VAC 3��� N WHITE227568=200-240 VAC 3� BLACK227567=200-240 VAC 1� RED232617=230 VAC 1� + N GRAY
1
![Page 2: NORDSON CORPORATION Vista Control Guideemanuals.nordson.com/adhesives/3000V/3100v/manuals/321213c.pdf · Vista Control Guide P/N 321213C Standard or Pattern Control TC Circuit Boards](https://reader033.vdocuments.net/reader033/viewer/2022050607/5fae1d90fc341f01835aeaac/html5/thumbnails/2.jpg)
Vista Control Guide P/N 321213C
Operator Interface
Main Key Functions
2
Change fromoperating mode toSTANDBY mode(lowers alltemperatures)
Activate/deactivateclock timer
CLEAR FAULTS(Reset)
Main switch
Selectsetting:
Setpoint(s)StandbySystem Clock
ENTER
![Page 3: NORDSON CORPORATION Vista Control Guideemanuals.nordson.com/adhesives/3000V/3100v/manuals/321213c.pdf · Vista Control Guide P/N 321213C Standard or Pattern Control TC Circuit Boards](https://reader033.vdocuments.net/reader033/viewer/2022050607/5fae1d90fc341f01835aeaac/html5/thumbnails/3.jpg)
Vista Control Guide P/N 321 213C
Operator Interface
3
Vista Control
Unit is ready for operation
Temperature of hose 1is shown
Unit scans onezone after the other (LEDOFF) or displays onlyone zone (LED ON)
All heaters areenabled
The pump isenabled
Actual temperature is 171°C
Setpoint is 171°C
State: Ready for operation
Present zone displayed
Move through settings inincrements of 10
![Page 4: NORDSON CORPORATION Vista Control Guideemanuals.nordson.com/adhesives/3000V/3100v/manuals/321213c.pdf · Vista Control Guide P/N 321213C Standard or Pattern Control TC Circuit Boards](https://reader033.vdocuments.net/reader033/viewer/2022050607/5fae1d90fc341f01835aeaac/html5/thumbnails/4.jpg)
Vista Control Guide P/N 321 213C
Programming: Temperatures
®
Vista™
POWER
MONITORSCAN
STANDBY
HEATERS
CLOCK
PUMP
CLEARFAULTS
TEMPERATURE
SETPOINT
STANDBY INTERNAL HOSE GUN
12
SYSTEMSETTINGS
CLOCK
SET TIME
ENTERSTANDBY
EXITSTANDBY
HEATERS ON
HEATERS OFF
INTERVAL
12
FAULT READY
4
Example: Set temperature of hose 1 from 171°C to 175°C
1. Choose SETPOINTby pressing
5. Press ENTERto acceptnew setting
Action Display
2. Illuminate HOSEsymbol bypressing
3. Set Channel 1with
4. Press UP keyto increaseSETPOINT
6. PressMONITOR/SCAN
DONE
SETPOINT
STANDBY INTERNAL HOSE GUN
1
2
SYSTEMSETTINGS
CLOCK
![Page 5: NORDSON CORPORATION Vista Control Guideemanuals.nordson.com/adhesives/3000V/3100v/manuals/321213c.pdf · Vista Control Guide P/N 321213C Standard or Pattern Control TC Circuit Boards](https://reader033.vdocuments.net/reader033/viewer/2022050607/5fae1d90fc341f01835aeaac/html5/thumbnails/5.jpg)
Vista Control Guide P/N 321213C
Programming: Set Current Time
5
Example: Set the actual time for the clock
Action Display
1. Choose CLOCK SETTIME by pressing
9. Press MONITOR/SCANto continue
DONE
2. The initial setting for theday and time will be dis-played (e.g. Monday, 7.00hours)
3. Press the UP keyto set thecorrect day ofthe week
(Monday = 1, Tuesday = 2,...Sunday = 7)
4. Press ENTER toaccept the new day
5. Now the actual hour beginsto flash; use the UP/DOWNkeys to set the correct hour
6. Press ENTER to acceptthe new hour
7. Now the actual minute beginsto flash; use the UP/DOWNkeys to set the correct minute
8. Press the ENTERbutton to accept thenew minutes
®
Vista™
POWER
MONITORSCAN
STANDBY
HEATERS
CLOCK
PUMP
CLEARFAULTS
TEMPERATURE
SETPOINT
STANDBY INTERNAL HOSE GUN
12
SYSTEMSETTINGS
CLOCK
SET TIME
ENTERSTANDBY
EXITSTANDBY
HEATERS ON
HEATERS OFF
INTERVAL
12
FAULT READY
To set current time:
![Page 6: NORDSON CORPORATION Vista Control Guideemanuals.nordson.com/adhesives/3000V/3100v/manuals/321213c.pdf · Vista Control Guide P/N 321213C Standard or Pattern Control TC Circuit Boards](https://reader033.vdocuments.net/reader033/viewer/2022050607/5fae1d90fc341f01835aeaac/html5/thumbnails/6.jpg)
Vista Control Guide P/N 321213C
Programming: 7 Day Clock
6
Example: Set the START and STOP times for automatic heater operation
Action Display
1. Choose HEATERSON by pressing
8. Press ENTER toaccept the newminutes
Action Display
2. The presentSTART time forDay 1 will bedisplayed (e.g.Monday ,7.00 hours)
3. Press theUP keyto set theday of the week atwhich you wantthe unit to startautomatically
(Monday = 1, Tuesday = 2,...Sunday = 7)
4. Press ENTER toaccept the new day
5. Now the START-hour begins toflash; use theUP/DOWN key toset the desiredhour
6. Press ENTER toaccept the desiredhour
7. Now the Start-minute begins toflash; use theUP/DOWN keysto set the desiredminute
9. Repeat steps 2 to 8 for all days of the week on which you wantthe unit to start automatically
10. Choose HEATERSOFF by pressing
11. The present STOPtime for Day 1 willbe displayed
12. Use the procedure described in steps 3 to 9 to set STOPtimes according to your needs
13. PressMONITOR/SCANto continue
14. Activate theAUTOMATIC START& STOP FUNCTIONSby pressing CLOCK
![Page 7: NORDSON CORPORATION Vista Control Guideemanuals.nordson.com/adhesives/3000V/3100v/manuals/321213c.pdf · Vista Control Guide P/N 321213C Standard or Pattern Control TC Circuit Boards](https://reader033.vdocuments.net/reader033/viewer/2022050607/5fae1d90fc341f01835aeaac/html5/thumbnails/7.jpg)
Vista Control Guide P/N 321213C
Programming: Password & System Settings
7
®
Vista™
POWER
MONITORSCAN
STANDBY
HEATERS
CLOCK
PUMP
CLEARFAULTS
TEMPERATURE
SETPOINT
STANDBY INTERNAL HOSE GUN
12
SYSTEMSETTINGS
CLOCK
SET TIME
ENTERSTANDBY
EXITSTANDBY
HEATERS ON
HEATERS OFF
INTERVAL
12
FAULT READY
Programming System Controls
Action Display
1. Choose SYSTEMSETTINGS bypressing
SYSTEMSETTINGS
CLOCK
SET TIME
ENTERSTANDBY
2. To change fromone system settingto the next one, use
3. To change the value of thedisplayed system setting,use the UP/DOWN keys
4. To accept a system settingchange, use theENTER key
Important!
If password function is activated, you get the following display:
If password function is NOTactivated, it looks like this:
5. Press MONITOR/SCAN
DONE
System settings cannot bechanged until password isentered.
Enter the system password bypressing,
then press the ENTER key.
![Page 8: NORDSON CORPORATION Vista Control Guideemanuals.nordson.com/adhesives/3000V/3100v/manuals/321213c.pdf · Vista Control Guide P/N 321213C Standard or Pattern Control TC Circuit Boards](https://reader033.vdocuments.net/reader033/viewer/2022050607/5fae1d90fc341f01835aeaac/html5/thumbnails/8.jpg)
Vista Control Guide P/N 321213C
No. Function Description Standard (default) / Alternate Value Setting
0 !
1 !
2 !
3 !
4 !
5
6-19
20
21
22
23
24
25 !
26
27-29 !
30
31
32
50
Password input
Password enable
PMI-Delay
Overtemperature setting
ºF or ºC
Temp Warning general
Temp Warning for zones
Sequential start orsimultaneous
Display heater signal
Function of warningcontact
System ready,or pump ON
Auto Energize Pump
Auto Energize heaters
Operating hours
Fault log 1-3
I/O Board only
I/O Board only
Energize pump
Energize PC(Pattern Control)
Allows the entering of apassword
Activate/DeactivatePassword protection
Set Ready Delay time
What temperature shallactivate an alarm?
Temperature units
Warning band for temperaturedeviation
Allows individual warning bandsetting for each zone
Zones heat sequentially or at thesame time (simultaneously)
Proportioning LED for diagnostics(for displayed zone only)
Warning contact could beused as Power Indication
Ready if temperatures arereached or is pump activated?
Pump switch ON if temperaturesare reached?
Heaters ON if unit is ON?
Hours with heaters on
Last fault = 1
Auto-standby timeout
In-standby timeout
Switches Pump ON at adefined tank temperature
34-36! Warning Log 1-3 Last warning = 34
Switches PC ON whenpower ON
(Password cannot be changed,fixed 321)
OFF - 0 / ON - 1
18 min / 0-60 min.
52ºC / 52-246ºC (SET FIRST!!!)125ºF / 125-475ºF
(F) Fahrenheit / (C) Celsius
18ºC / 6-28ºC30ºF / 10-50ºF18ºC / 6-28ºC 30ºF / 10-50ºF6 = Tank 7 = Grid8-13 = Hoses 14-19 = Guns
Sequential - 1 / Simultaneous - 0
OFF - 0 / ON - 1
Warning - 1 / Power - 0
Temperatures reached - 1Pump ON - 0
Automatic ON - 1 / Manual ON - 0
Yes - 1 / No - 0
Display (no choice)
Display (no choice)
Display (no choice)
0 / 0-1440 minutes
0 / 0-1440 minutes
36ºC / 0-232ºC100ºF / 0-450ºF
Yes - 1 / No - 0
51 Remote Pattern Select Select enhanced or I/O boardfunctions
0 = Enhanced I/O as is1 = Select 3 patterns (via x1-5, 6, 17, 18)
2 = Select 7 patterns (via x1-5, 6, 13, 14, 17, 18)
Note: ! indicates most important features
Programming: System Settings
8
![Page 9: NORDSON CORPORATION Vista Control Guideemanuals.nordson.com/adhesives/3000V/3100v/manuals/321213c.pdf · Vista Control Guide P/N 321213C Standard or Pattern Control TC Circuit Boards](https://reader033.vdocuments.net/reader033/viewer/2022050607/5fae1d90fc341f01835aeaac/html5/thumbnails/9.jpg)
Vista Control Guide P/N 321213C9
Examples of Fault Displays
Overtemperature fault on gun 2. Actual temperatureof gun 2 is 230°C.
Undertemperature fault on Hose 3. Actual tempera-ture of hose 3 is 120°C.
RTD open on Hose 1. Shorted tank RTD on the tank.
Start-up display looks like this:This is NOT a fault.It shows software revision 1.003.
IndicatesFlashing
Light
Reading Fault/Warning Log
SystemSetting Channel Fault
CodeHours of
Use
Code Fault Warning
1 Undertemperature _
2 Open RTD Open RTD
3 Shorted RTD Shorted RTD
4 Overtemperature Out of band
5 Control board bad
6 Brown out
7 Pattern control powerboard fault
Pattern control powerboard fault
8 Pattern control engineboard fault
Pattern control powerboard fault
9 Pattern control engineboard
Pattern control engineboard
Fault/Warning Codes
_
_
![Page 10: NORDSON CORPORATION Vista Control Guideemanuals.nordson.com/adhesives/3000V/3100v/manuals/321213c.pdf · Vista Control Guide P/N 321213C Standard or Pattern Control TC Circuit Boards](https://reader033.vdocuments.net/reader033/viewer/2022050607/5fae1d90fc341f01835aeaac/html5/thumbnails/10.jpg)
Vista Control Guide P/N 321 213C
Troubleshooting
No adhesive / melter not ready Power / melter switched off Check for READY lightRefer to manual, Section A-2
No adhesive / melter ready Pump does not work or noadhesive reaching the nozzle
Check system settings (page 8)Check pump state
Perform filter flushRefer to manual, Section A-5
Adhesive bead too long or tooshort
Pattern control programmingneeds modification
Reprogram pattern control
Carton open after gluing
Appearance of glue:
Adhesive too cold
Cartons too cold
Nozzle too far away from carton
Not enough air pressure for gun oradhesive pressure not sufficient
Nozzle clogged
Air pressure not sufficient, partlynozzle, damaged nozzle oradhesive too cold
Check system settings (page 8)
Check system settings (page 8)
Change nozzle position
Perform nozzle cleaning,change nozzle if necessary
Check air pressure and filter,clean nozzles and check
No adhesive / just a little adhesiveon one side
Not enough adhesive,“hammerhead” at the beginningof a bead
Adhesive bead in thewrong position
Activation of guns too early ortoo late
Check actuation sensor positioningon parent machine
10
Problem Reason Action
![Page 11: NORDSON CORPORATION Vista Control Guideemanuals.nordson.com/adhesives/3000V/3100v/manuals/321213c.pdf · Vista Control Guide P/N 321213C Standard or Pattern Control TC Circuit Boards](https://reader033.vdocuments.net/reader033/viewer/2022050607/5fae1d90fc341f01835aeaac/html5/thumbnails/11.jpg)
Vista Control Guide P/N 321213C
Standard or Pattern Control TC
Circuit Boards (pg. 1)
Vista Control Stack (standard units) 234428 326613 305607(480V) 328921 N/A 328929
Vista Control Stack (pattern control units) 297710 307075 N/A(480V) 328923 N/A N/A
Vista Membrane Panel (standard units) 225458 227577 232682Vista Control End Frame 234423 234423 234423Vista Power Board 234427 234427 234427Vista Control Board 234429 326614 248043Vista Display Board (standard units) 234426 234426 248044Vista Display Board (pattern control units) 247267 247267 N/AContactor Board 247266 247266 247266Grid Power Board 247265 247265 N/APattern Control Engine Board 247263 247263 N/APattern Control Driver Board 247264 247264 N/AStandard Input/Output (I/O) Board 247261 247261 N/AEnhanced I/O Board 239494 239494 N/ATC I/O Board N/A N/A 248045Motor Control Board N/A 326620 N/A5/6 Hose/Gun Board 247260 N/A N/A400 VAC Tank Board 247262 N/A 247262480 VAC Board 333342 N/A N/A
FusesPower Board
Fuse, 1A (2 required) 310904 310904 310904Fuse, 6.3A (8 required) 939683 939683 939683Fuse, 25A (2 required) 939491 939491 939491
Contactor BoardFuse, 25A (2 required) 939491 939491 939491Fuse, 30A (1 required) 939992 939992 939992
5/6 Hose/Gun BoardFuse, 6.3A (4 required) 939683 939683 N/A
Pattern Control Drive BoardFuse, 6.3A (2 required) 939683 939683 N/AFuse, 1A (1 required) 232515 232515 N/A
Motor Control BoardFuse, 4A (2 required) N/A 114876 N/A
480 VAC Distribution BoardFuse, 20A (3 required) 939021 N/A N/AFuse, 16A (1 required) 297747 N/A N/A
RTD Service Kit 108907 108907 108907Thermostat Service Kit 249800 249800 249800
12345
5
Recommended Spare Parts
11
Piston Pump Gear Pump Piston Pump
![Page 12: NORDSON CORPORATION Vista Control Guideemanuals.nordson.com/adhesives/3000V/3100v/manuals/321213c.pdf · Vista Control Guide P/N 321213C Standard or Pattern Control TC Circuit Boards](https://reader033.vdocuments.net/reader033/viewer/2022050607/5fae1d90fc341f01835aeaac/html5/thumbnails/12.jpg)
© Nordson Corporation 2000All Rights Reserved
P/N 321 213CIssued 2/00
Record of Vista Control Settings
ZoneType
Zone 1 Temperatures Zone 2 Temperatures Zone 3 Temperatures
Internal
Hose
Gun
Operating Standby Band Operating Standby Band
ZoneType
Zone 4 Temperatures Zone 5 Temperatures Zone 6 Temperatures
Hose
Gun
Operating Standby Band Operating Standby Band Operating Standby Band
Temperature Settings
Clock Settings
Heater Intervals
Operating Standby Band
Monday Tuesday Wednesday Thursday Friday Saturday Sunday
Heaters On-1
Heaters Off-1
Heaters On-2
Heaters Off-2
Standby Intervals
Standby On-1
Standby Off-1
Standby On-2
Standby Off-2
System Settings
System ready time delay:
Overtemperature setpoint:
Pump air pressure:
Global temperature band:
Auto-energize pump temperature setting:
Startup: Sequential Simultaneous
Auto-energize heaters: On Off
Auto-energize pump: On Off
Warning or power output: Warning Power on
Password: On Off