northern sales office d-24955 harrislee multifunction ... · iso certificate compressed air...
TRANSCRIPT
www.cs-instruments.com�
NortherN sales officeam oxer 28c D-24955 harrislee
foN: +49 (0) 46� 700 20 25 fax: +49 (0) 46� 700 20 26email: [email protected]: www.cs-instruments.com
southerN sales officeZindelsteiner straße �5 D-78052 Vs-tannheim
tel: +49 (0) 7705 97 89 9-0 fax: +49 (0) 7705 97 89 9-20email: [email protected]
USB
Special featUreS
• Graphicevaluationofactual consumption,leakage,pressure,dewpoint, currentconsumption
• Costcalculationofleakageandcompressed aircontsumption
• User-specificanalysis:Whichplantuseshow muchcompressedair?
MultifunctionMeasuringInstrumentDS 300forCompressedAirandGases
bar
m³/h
°ctd a
www.cs-instruments.com2
StationaryflowandconsumptionmeasurementVA300withmultifunctionmeterDS 300
technical Data DS 300
Technicaldataconsumptionprobepleaseseepage6
Dimensions: 92x92x55mm,IP65 (panelmounting)
inputs: 2digitalinputsfor VA300resp.FA300
interface: USB,CSdatacollector
Keypad: 4keys
Power supply: 90-260VAC,50-60Hz
accuracy: Seesensordatapage6
alarm outputs: 2relays,230VAC,3A
analogue output: 2x4...20mA
application temp.: 0...50°C
transport temp.: -20...70°C
OptiOnS
Wall housing: 118x115x93mm,IP65
Data logger: 500,000measuringvalues start-/stopzeit,measuring ratefreelyadjustable
rs 485: upto256xDS300, connectable,evaluationat PCviaCSSoftingraphicand tableform2 additional inputplug-in cards: 4-20mA,0-10V,Pt100,TC
Stationaryconsumptionmeasurement,availablewithandwithoutmeasuringsection
• Forpanelmounting (96x96mm)
• Forwallmounting • Easywallmounting
Therighthousingforeachapplication:
all-in-one measuring stationreadyforplug-in,consistingof
• Measuringsection• MultifunctionmeterDS300• ConsumptionprobeVA300
Special featUreS• All-in-onesolution,easyinstallation
• 2displays:Actualflowandtotalair consumption
• Easyinstallationandremovalofthe sensorunderpressure
• Highestaccuracydueto5point calibration
• Output4to20mAform³/h,pulse outputform³
• Easytohandle: -Innerdiameterfreelyadjustable inDS300 -2alarmvaluesfreelyadjustable -Opticaldisplayincaseofalarm -Consumptioncounterresettable
www.cs-instruments.com�
Data recording and evaluation atthePC–upto256 flow stations
Special featUreS:• Upto256flowstationsconnectablevia RS485
• Upto500,000measuringdataare storedineachsingleinstrumentDS300
• Onlinereadoutofthedataofeach measuringsiteatthePC(currentflowin m³/h,totalairconsumptioninm³)
• ReadoutofthedataviaCSUSB datacollector,upto64xDS300 (128MB)
• ReprogrammingofDS300viaCSUSB datacollector
cOmplete flOw StatiOn withOUt Data lOgger anD rS 485 with meaSUring SectiOn
(pleaSe See pictUre page 2) OrDer nO.
DN6 upto85 l/min 06010060
DN15 upto750 l/min 06010061
DN20 upto85 m³/h 06010062
DN25 upto140 m³/h 06010063
DN32 upto260 m³/h 06010064
DN40 upto360 m³/h 06010065
DN50 upto600 m³/h 06010066
DN65 upto1,100 m³/h 06010067
DN80 upto1,600 m³/h 06010068
DN100 upto2,700 m³/h 06010069
DN125 upto4,000 m³/h 06010070
DN150 upto5,800 m³/h 06010071
DN200 upto8,800 m³/h 06010072
acceSSOrieS OrDer nO.
OptionDS300withdataloggerfor 05003100500,000measuredvalues
OptionDS300withRS485and 05003200dataloggerfor500,000
CSdatacollectorforreadingout 05547000upto64xDS300andforreprogramming
Basicsoftwareforeasyconfiguration 05992000oftheflowstation
CSSoftProfessional, 05547010dataevaluationingraphicandtableformwithUSBcable
CSSoftProfessionalRS485, 05547020dataevaluationingraphicandtableformwithRS485/USB
5pointprecisioncalibrationwith 32000001ISOcertificate
Pleasetakeorderdetailsandfurtheraccessoriesfromthepricelist
• USBinterfaceandCSdatacollector
• CS-Softforevaluationin graphicandtableform
USB
rS 485
www.cs-instruments.com4
CompressedairanalysiswithDS 300ThemultifunctiondisplayDS 300givestheuserasurveyonthewholecompressedairnet
Graphicevaluationofallrelevantdata
Allrelevantmeasuringdataforaneconomicoperationofthecompressedairlineataglance:
• Actualairconsumptioninm³/h orm³/min
• Totalairconsumptioninm³
• Pressuredewpointin°Ctd
• Linepressureinbar
• CurrentconsumptioninA
• Temperaturein°C
ThedatatransfertothePCiseffected:
• bymeansoftheCSdatacollector
(manually)
•viaUSBinterfaceforshortdistancePC todisplayDS300
• viaRS485interfaceforlongdistances
TheCSdatacollector(USB)isableto:
• readoutupto64xDS300atthePC
• evaluatedataintheCSSoftProfessional
• reprogramDS300
technical Data
Consumptionprobe:pleaseseepage6
MultifunctiondisplayDS300:pleaseseepage2
clamp-On ammeter:
measuring range: 0 to 500 a
accuracy: ± 0.5 %
Dew pOint prOBe fa 300-2:
measuring range: -80 to 20 °ctd
accuracy: ± 2 °ctd at -40 °ctd
preSSUre prOBe:
measuring range: 0 to �6 bar
accuracy: ± 0,5 %
USB
cS-BUS(rS-485)
alarm relay
4 ... 20 ma output
bar
www.cs-instruments.com5
cS Soft professionalwithleakagecalculationThedatacollectedinDS300canbeevalu-atedbymeansofthenewlydeveloped cS Soft professional with leakage calcula-tion whichwasespeciallydevelopedforthecompressedairbranch.
1. Howisleakagedetermined? Theeasiestwayistheleakagedeter- minationonproduction-freedays, e.g.weekends,holidays,attheendof ashift.Duringthistimethecompressor carriescompressedairwhichisre- quiredtokeepaconstantpressure. Accordingtostatisticsevenifproduc- tioniseffecteddayandnightthereis atleastoneshortperiodoftimeduring whichallloadisswitchedoff,e.g. maintenancetimes.
Thisperiodoftimeisdeterminedauto- maticallybytheCSSoftProfessional.
2.Whathastobedonebytheuser? Theuserhastoenterthefollowing parameters: -CurrentcostsperkWh -Meas.rate,durationofmeasurement
3.Whichevaluationsdoestheuserget? Apartfromthegraphicevaluationwith curveprogressionsofallmeasured datathecustomerwillgetinformationon:
-thetotalairconsumptioninm³ -theleakageintotalinm³and%ofthe totalairconsumption -thecurrentconsumptioninkWh -costsperm³ofproducedcompressed airin€ -costsoftheleakagein€ -pressureprogression -pressuredewpointprogression
Pleasetakeorderdetailsandfurtheraccessoriesfromthepricelist
cOmplete flOw StatiOn
with meaSUring SectiOn: OrDer nO.
DN6 upto85 l/min 06010160
DN15 upto750 l/min 06010161
DN20 upto85 m³/h 06010162
DN25 upto140 m³/h 06010163
DN32 upto260 m³/h 06010164
DN40 upto360 m³/h 06010165
DN50 upto600 m³/h 06010166
DN65 upto1,100 m³/h 06010167
DN80 upto1,600 m³/h 06010168
DN100 upto2,700 m³/h 06010169
DN125 upto4,000 m³/h 06010170
DN150 upto5,800 m³/h 06010171
DN200 upto8,800 m³/h 06010172
acceSSOrieS OrDer nO.
OptionDS300withRS485and 05003220dataloggerfor500,000measuringvalues,incl.2additionalplug-incards
CSdatacollectorforreadingoutand 05547000programmingupto64xDS300
Basicsoftwareforeasy 05992000configurationofDS300
CSSoftProfessional,dataevaluation 05547010ingraphicandtableformwithUSBcable
CSSoftProfessionalRS485,data 05547020evaluationingraphicandtableformwithcableRS485/USB
CScompressedairanalysissoftware 05992010forleakageandcostcalculation
Clamp-onammeter0to500A 05540500
FA300-21,pressuredewpointprobe 06993024from-80to+20°Ctd
Pressureprobefrom0to16bar 06941886
5pointprecisioncalibrationwith 32000001ISOcertificate
CompressedairanalysiswithleakagecalculationMeas.period31.12.2006until31.01.2007,meas.rate1second
cOmpreSSeD air cOnSUmptiOnTotalconsumption: Averageconsumption: Maximumconsumption:
1,309,013m³ 1,805m³/h 2,400m³/h
leakageLeakageintotal: Averageleakage: Leakagerate:
299,000m³ 415m³/h 23%
energy DataTotalenergyconsumption: Energycosts: Energycostsperm³:
129,000KWh 129,000KWhx0.11€=14,190€ 14,190€/1,309,013m³
=0.011€/m³
fUrther meaSUring DataMaximumpressure: Minimumpressure: Averagevalue:
7bar 5.8bar 6bar
Maximumdewpoint: Minimumdewpoint:
-11°Ctd -50°Ctd
leakage costs: 299,000 m³ x 0.011 € = 3,289 € for 1 month
DeScriptiOn:
completely wired plug-in flow station consisting of:DS300(withdataloggerfor500,000measuredvalues),currentairconsumptioninm³/h,totalconsump-tioninm³including2additionalplug-incards(4-20mA,0-10V,Pt100,TC)ConsumptionprobeVA300-80standardversion,meas.sectionsfromDN6toDN200
www.cs-instruments.com6
MultifunctionMeasuringInstrumentDS 300forCompressedAirandGases
Special featUreS• Internaldatamemory
• Innerdiameteradjustableinhand-held instrument
• Easyinstallationandremovalofthe sensorunderpressurevia1/2”ballvalve
• 4hourspowerindependent measurements
technical Data
mOBile cOnSUmptiOn prOBe Va 300:
measured variables: m/s,m³/hbzw.m³/min,l/min
inner diameter freely adjustable in cs 2�90-5
Data memory: 6.000measuredvalues
Principle of meas.: calorimetricmeasurement
measuring medium: Air,gas
measuring range: 0...26.400m³/h
(seetablebelow) accuracy without measuring section: ±4%m.v.,±3%m.v.with
5pointISOprecisioncertificate
application temp.: -30upto110°Cprobetube -30upto80°Chousing
operating pressure: upto50bar
Probe tube: stainlesssteel,1.4301 totallengthstandard 220mm,Ø9mm
screw thread: G1/2”
Power supply: hand-heldinstrum.12VDC
StatiOnary cOnSUmptiOn prOBe Va 300-80:
additionally to the above mentioned data:
VariablesfreelyselectableinDS300:m³/s,m³/h,m³/min,l/minl/sec,ft/min,cfm
Diameter freely adjustable in Ds �00
accuracy with measuring section:±3%m.v.,±2%m.v.with5pointISOprecisioncertificate
Power supply: 12-30VDC
flOw meaS. rangeS mOBile + StatiOnary
standard max
Inch mm VA300-80 VA300-120 Unit
VA300-81 VA300-121
1/4” 6,0 0.8...85 1.0...120 l/min
1/2” 16,1 2.5...750 3.5...1,100 l/min
3/4” 21,7 0.3...90 0.4...120 m³/h
1” 27,3 0.5...150 0.6...200 m³/h
11/4” 36,0 0.9...280 1.2...350 m³/h
11/2” 41,8 1.2...370 1.5...500 m³/h
2” 53,1 2...600 2.5...800 m³/h
21/2” 68,9 3.5...1,100 5...1,500 m³/h
3” 84,9 5...1,600 7...2,200 m³/h
4” 110,3 9...2,700 12...3,600 m³/h
5” 133,7 13...4,000 18...5,300 m³/h
6” 162,3 18...5,800 25...8,000 m³/h
8” 200 26...8,800 33...11,700 m³/h
10” 250 40...13,700 52...18,900 m³/h
12” 300 60...19,800 80...26,400 m³/haccordingtoDIN1945,ISO1217relatedto20°C,
1000mbar
DeScriptiOn OrDer nO.mobile set for consumption measurement (max. version) consisting of: 0600 �0�0
CS2390-5mobilehand-heldinstr. 05602395
3measuringchannels
Rechargeablebatterypackforlong- 05151002
termmeasuringapprox.4hours
Mainsadapter12VDC230VAC 23902290
Portableconsumptionprobe 33000121VA300-121forCS2390-5,max.versionwith2mcabletoCS2390-5,includingcertificate
CSSoftSoftwarefordisplayingraphic 32001101
ortableform
PCconnectioncableV24RS232 23901909
USBRS232adapter 32001013
Professionaltransportcase 05546000
further accessories, not included in the set:
5pointprecisioncalibrationwith 32000001ISOcertificate
Mobilepressuredewpointprobe 06993003(-80to+50°Ctd)incl.meas.chamber,2mcabletoCS2390-5
Pleasetakeorderdetailsandfurtheraccessoriesfromthepricelist
www.cs-instruments.com7
lD 300 Ultrasonic leak Detector
cOSt SaVing
Inloudproductionandmachinehallsleakagescanonlybeheardiftheyhaveadiameterof1mmandmore.1holewithdiameter1mm=270EUR/yearLD300willbeamortizedafter4leakages.
Ultrasonic detector withlaser
applicatiOnSDeterminationofleakagesat:• Compressedairlines,gas,vapourandvalcuumplants• Refrigeratingplants• Doorseals
technical Data
Working frequency: 40kHz±2kHz
connections: 1)4-poleconnectionfor headsetandbatterycharger
2)3.5mmstereosocketfor sensorandcableconnection
laser: Wavelength:655upto660nm Outputpower:0.4upto0.5mW
energy supply: InternalNiMHbattery
operating duration: approx.6hourswithoutlaser approx.4hourswithlaser
charging time: approx.1.5hours
application temp.: 0°Cupto+40°C
storage temperature: -10°Cupto+50°C
telescope: 3x120cm
DeScriptiOn OrDer nO.
lD �00 ultrasonic detector set consisting of: 060� 0�0�
LD300Ultrasonicdetector 05600102
Ultrasonicsensor 06050001
Noiseisolatedheadset 05540102
Focustubewithfocustip 05300101
Cabletodetachsoundprobefrominstrument 05530101
Batterycharger 05540001
Transportcase 05540101
accessory - not included in the set:
Ultrasonictonegenerator 05540103
Telescopeextension3x120cm 05300102
BymeansofLD300leakagesinanultrasonicrangecanbedetectedwithoutanyproblemseveniftheyhaveadiameterfromapprox.0.1mm.Thetelescopicextensionisperfecttofindleakagesinpipelinesuptoaheightof6m.
Special featUreS:• Preciselocatingbymeansoflaser• Focustubeavoidsinfluencebyambientnoise• Noiseisolatedheadset
www.cs-instruments.com8
Usefulaccessories,measuring sections
1. Measuringsectionsforprecisemeasurements,from Dn 80 with Din flange connection
2.Whatifno1/2” ball valve isexistingatthemeasuringsite?Bymeansofaspecialdrillingdeviceameasuringsitewith1/2”ballvalvecanbeeasilysetupwithinafewminutesatanyplaceinthecompressedairsystem.
OD tUBe external threaD tUBe tOtal lenght OrDer nO.
20.0mm G1/4“ 20.0x7.0mm 180mm 40000006
21.3mm G1/2” 21.3x2.6mm 500mm 40000015
26.9mm G3/4” 26.9x2.6mm 600mm 40000020
33.7mm G1” 33.7x3.2mm 750mm 40000025
42.4mm G11/4” 42.4x3,.2mm 900mm 40000032
48.3mm G11/2” 48.3x3.2mm 1000mm 40000040
60.3mm G2” 60.3x3.6mm 1250mm 40000050
76.1mm G21/2” 76.1x3.6mm 1500mm 40000065
FlangeDIN2633
88.9mm DN80/88.9 88.9x2.0mm 1850mm 40000080
114.3mm DN100/114,3 114.3x2.0mm 2104mm 40000100
139.7mm DN125/139,7 139.7x3.0mm 2860mm 40000125
168.3mm DN150/168.3 168.3x3.0mm 3110mm 40000150
• Drillingunderpressure
DeScriptiOn OrDer nO.
Drillingjigincludingdrill 05301108
High-pressureprotection 05301105recommendedformeasurementsfrom10barupto50bar
Spotdrillingcollaroutertube 05000453diameter58-65mm,includingballvalve
Spotdrillingcollaroutertube 05000454diameter67-74mm,includingballvalve
Spotdrillingcollarsforother onrequestdiameters
• Measuringsection1/4”
• Measuringsection1/2”
• Drillingdevice
• High-pressureprotection
• Spotdrillingcollar