notes: 1. installation shall comply with all … · 2019. 7. 17. · forced air intake area heat...
TRANSCRIPT
90.0
FRONT VIEWCABINET DOORS AND INPUT/OUTPUT DEADFRONT
REMOVED FOR CLARITY
HEATSINKCABINET
CIRCUIT BREAKERCABINET
INPUT/OUTPUTCABINET
USER INTERFACECONNECTIONSEE DETAIL
S1 INPUT
S1 BYPASS
LOAD ALOAD B
S2 INPUT
S2 BYPASS
4X 3.5
4X 2.52 PLCS
4X 6.03 PLCS
14X 4.0 CONDUIT HOLES AND LOCATIONS FOR REF ONLY.
HOLES TO BE CREATED IN THE FIELD.
4.2
4X 5.02 PLCSFAN
TOP VIEWNON USEABLE AREA
2X 10.0 X 25.0CABLE ACCESS OPENING
FRONTCUSTOMERCOMMUNICATIONACCESS
REAR
9.4 X 24.4PERFORATED AREA
2X 7.0 X 9.4PERFORATED AREA
3X 26.03 PLCS
3X 4.02 PLCS
18X .56
6X 14.5
6X 28.8
4.2
4X 3.5
4X 6.03 PLCS
4X 2.52 PLCS
4X 5.02 PLCS
14X 4.0 CONDUIT HOLES AND LOCATIONS FOR REF ONLY. HOLES TO BE CREATED IN THE FIELD.
FRONT
REAR
BOTTOM VIEW
NON USEABLE AREA
CUSTOMERCOMMUNICATIONACCESS
2X 10.0 X 25.0CABLE ACCESS OPENING
42.0
90.0
36.0
OPERATIONAL AND SERVICE NEC REQUIRED ACCESS
PLAN VIEWACCESS REQUIREMENTS
SCALE 1:10
FRONT
FRONT
ISOMETRIC VIEW
HEAT SINK BAYFORCED AIR INTAKE
AREA
HEAT SINK BAYFORCED AIR OUTLET
AREA
TOUCHSCREENDISPLAY
CIRCUIT BREAKER BAYPASSIVE AIR OUTLETAREA
USERINPUTS
ETHERNET
ALARM RELAYS
REMOTEEPO
USER INTERFACE CONNECTION DETAILSCALE 1:4
MODBUS
USERINPUTS
NOTES:
1. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES.
2. REFER TO PRODUCT DOCUMENTATION FOR ADDITIONAL DETAILS PRIOR TO SITE PREPARATION OR INSTALLATION.
3. OPERATING TEMPERATURE RANGE: 0 TO 40 C.
4. SYSTEM COOLING REQUIREMENTS: FORCED AND EXHAUST AIR COOLED.
5. SYSTEM WEIGHT: HEAT SINK BAY 1515 LBS (689 kg)
CIRCUIT BREAKER BAY 2360 LBS (1073 kg)
INPUT/OUTPUT BAY 915 LBS (416 kg)
TOTAL 4790 LBS (2177 kg)
6. OPERATIONAL ACCESS VIA FRONT DOORS. MAINTENANCE AND CONNECTION ACCESS VIA FRONT DOORS AND REMOVEABLE SIDE OR REAR PANELS (DEPENDING ON ACCESS - SEE NOTE 7).
7. RECOMMENDED MINIMUM CLEARANCES: FRONT = 42" LEFT = 42" OPTIONAL RIGHT = 42" OPTIONAL TOP = 60"
8. SYSTEM MUST HAVE ALL PANELS AND DOORS INSTALLED FOR PROPER OPERATION.
9. FINISH: FRAME AND OUTER PANELS, POWDER COAT INTERIOR, GALVANIZED ZINC ELECTROPLATE.
10. CABLE ENTRY: TOP ENTRY - TOP EXIT BOTTOM ENTRY - BOTTOM EXIT TOP ENTRY - BOTTOM EXIT BOTTOM ENTRY - TOP EXIT
11. BUSBAR TERMINALS FURNISHED WITH NEMA 2-HOLE LANDINGS. SEE SHEET 2 DETAILS A, B, AND C.
12. 1600A DESIGNED FOR CABLE SIZES UP TO 6X 750 MCM PER PHASE.
A01 -- PLH UPDATING LABELS 4/25/2018A00 -- PLH INITIAL RELEASE 02/22/2018Rev. ECN# Resp. Description Date
Revision Table
DSheet Size
PD
Power Protection
OutlineScale
Document Kind Title
Document ID PageDivision/Dept.
Approved
Prepared
We reserve all rights in this docum
ent and in the information contained therein. R
eproduction, use or disclosure to third parties without express authority is strictly forbidden. ©
Copyright 2014 A
BB
.
PLHDWG: OUTLINE, 1600A SS4
1:16
94-9200-00000201 1 / 2
02/22/2018Date Drawn
UnitsInch
94-9200-00000201Item No.
Interpret drawing in accordance with ASME Y14.5-2009.
Doc. Rev.
A01
A01Item Rev.
N/AReference
X.XXX = ±.030
X.XX = None
Tolerance
Part must comply with company doc. 94-10-000001.
0
25.6 A OUTPUT
29.4 B OUTPUT
39.0 A S1 INPUT
42.8 B S1 INPUT
46.5 C S1 INPUT
50.3 A S2 INPUT
54.0 B S2 INPUT
57.8 C S2 INPUT
33.1 C OUTPUT
68.1 GROUND
REAR VIEWINPUT/OUTPUT BAY PANEL AND BUS BAR SUPPORTS
REMOVED FOR CLARITY
HEAT SINK BAYCIRCUIT BREAKER BAYINPUT/OUTPUT BAY
0
9.2
NE
UTR
AL
0
21.1NEUTRAL
A
B
C
RIGHT VIEWPANELS AND I/O BUS BAR SUPPORTS
REMOVED FOR CLARITYLEFT VIEW
PANEL REMOVED FOR CLARITY
44.6
16.8
FRONT VIEW HEAT SINK BAYCENTER OF GRAVITY LOCATION
44.5
16.5
FRONT VIEW CIRCUIT BREAKER BAYCENTER OF GRAVITY LOCATION
CENTEROF GRAVITY
45.3
15.2 FRONT VIEW INPUT/OUTPUT BAYCENTER OF GRAVITY LOCATION
CENTEROF GRAVITY
17.3 15.2 19.3
1.24 TYP 4.00
2X 1.24 TYP 2X 2.88 TYP
2X 2.57
DETAIL ANEUTRAL BUS BAR
SCALE 1:4
1/2 13-UNC NUT TYP
32X NEMA 2 HOLE CONNECTION
1.75 TYP 4.0
2X 1.00
2X 2.00 TYP
.531 TYP
DETAIL BCUSTOMER GROUND BUS BAR
SCALE 1:4
9X NEMA 2 HOLE2 SIDED CONNECTION
6.0
3X .88 2 PLCS
3X 1.75 2 PLCS
4X 1.00
4X 2.00 TYP .531 TYP
DETAIL CCUSTOMER BUS BAR
SCALE 1:4
6X NEMA 2 HOLE2 SIDED CONNECTION
CENTEROF GRAVITY
2 / 21:1294-9200-00000201DWG: OUTLINE, 1600A SS4Division/Dept. Title Document ID Scale Page
Power Protection
We reserve all rights in this docum
ent and in the information contained therein. R
eproduction, use or disclosure to third parties without express authority is strictly forbidden. ©
Copyright 2014 A
BB
.
A01Doc. Rev.