----------- ------ NOTES: N.R. -Not required N.A.- Not applicable ADMINISTRATION {Chapter 1) Complete construction documents Signed/sealed construction documents (106.1, 106.2) (106.1, State Jaws vary) BUILDING PLANNING {Chapters 3, 4, 5, 6) OCCUPANCY CLASSIFICATION (302 - 312, 508) Single Occupancy (302.1) Incidental uses (508.2) Mixed Occupancy (508.3) Accessory occupancies (508.3.1) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to determine the allowable height and area and permitted types of construction for a building containing a single occupancy or nonseparated mixed occupancies. Apply Case 2 to determine the allowable height and area and permitted types of construction for a building containing separated mixed occupancies. AREA MODIFICATIONS TO TABLE 503 Allowable tabular area, At (Table 503) 1 Frontage (506.2) Area Increase Factor due North East South West to Frontage, It (506.2) + Total Area Increase Factor due to Frontage (F) ____ ft. Perimeter (P) ___ft. automatic sprinklers, Is (506.3) + Width of open space (W) = _______ Conversion factor = Area Increase Factor due to Frontage, It= _______ (506.2) It= [F -0.25] W p 30 CASE 1 -SINGLE OCCUPANCY OR NONSEPARATED OCCUPANCIES (508.3.2) Using Table 503, identify the allowable height and area of the single occupancy or the most restrictive of the nonseparated mixed occupancies. Construction types that provide an allowable tabular area equal to or greater than the adjusted building area and allowable heights (as modified by Section 504) equal to or greater than the actual building height are permitted. DETERMINE CONSTRUCTION TYPE Actual building area ft2 Adjusted building area tt 2 actual building area + conversion factor Actual building height ___ feet ___stories Allowable building height ___ feet ___stories Permitted types of construction Type of construction assumed for review (602.1.1) CHECK ALLOWABLE AREA (506.4) Allowable area per floor (Aa) X = ft2 conversion factor tabular area (Table 503) Total floor area (all stories) __________ft 2 Allowable floor area (all stories) X = -:-::---:-:-----=-- Allowable area per floor number of stories (A,) (maximum 3) Compliance verified (Single Occ. or Nonsep.) ____ 1

Upload: others

Post on 27-Jun-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NOTES: N.R. N.A.- Not applicable ADMINISTRATION {Chapter 1) · Mixed Occupancy (508.3) Accessory occupancies (508.3.1) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to

-----------------

NOTES NR -Not required NA- Not applicable

ADMINISTRATION Chapter 1) Complete construction documents Signedsealed construction documents

(1061 1062) (1061 State Jaws vary)

BUILDING PLANNING Chapters 3 4 5 6) OCCUPANCY CLASSIFICATION (302 - 312 508)

Single Occupancy (3021) Incidental uses (5082)

Mixed Occupancy (5083) Accessory occupancies (50831)

GENERAL BUILDING LIMITATIONS (Chapters 5 amp 6)

Apply Case 1 to determine the allowable height and area and permitted types of construction for a building containing a single occupancy or nonseparated mixed occupancies Apply Case 2 to determine the allowable height and area and permitted types of construction for a building containing separated mixed occupancies

AREA MODIFICATIONS TO TABLE 503

Allowable tabular area At (Table 503) 1 Frontage (5062)

Area Increase Factor due North East South West to Frontage It (5062) +

Total Area Increase Factor due to Frontage (F)____ft Perimeter (P) ___ft

automatic sprinklers Is (5063) + Width of open space (W) =_______

Conversion factor = Area Increase Factor due to Frontage It=_______ (5062)

It= [F -025] W p 30

CASE 1 -SINGLE OCCUPANCY OR NONSEPARATED OCCUPANCIES (50832) Using Table 503 identify the allowable height and area of the single occupancy or the most restrictive of the nonseparated mixed occupancies Construction types that provide an allowable tabular area equal to or greater than the adjusted building area and allowable heights (as modified by Section 504) equal to or greater than the actual building height are permitted

DETERMINE CONSTRUCTION TYPE

Actual building area ft2

Adjusted building area tt2

actual building area + conversion factor

Actual building height ___ feet ___stories

Allowable building height ___ feet ___stories

Permitted types of construction

Type of construction assumed for review (60211)

CHECK ALLOWABLE AREA (5064)

Allowable area per floor (Aa)

X = ft2 ---~~~-conversion factor tabular area (Table 503)

Total floor area (all stories) __________ft2

Allowable floor area (all stories)

X = -----------=--Allowable area per floor number of stories (A) (maximum 3)

Compliance verified (Single Occ or Nonsep) ____

1

CASE 2- SEPARATED MIXED OCCUPANCIES (50833)

Using Table 503 identify the allowable height and area of each of the separated occupancies within the building Construc-tion types that provide for each story of the building tabular areas (as modified by Section 506) which result in a sum of the ratios of 100 or less and allowable heights (as modified by Section 504) equal to or greater than the actual height of the occupancy are permitted

Allow tab area A (Table 503)

Actual Adjusted Actual Allowable Story Group floor area floor area height height

ft2 ft2 ft stories ft stories ft2 tt2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories

t ( fl ) Area ra 10 smg e 1 oor = LJ Adjusted floor area =---+ + + tOO

Adjusted floor area= actual floor area_ conversion factor

CHECK ALLOWABLE AREA (5064)

Total area ratio (all floors)= Permitted types of construction _________

Two-story buildings (Total area ratio 2) Type of construction assumed for review (60211)

Three or more story buildings Compliance verified (Mixed Occ Separated) ____ (Total area ratio 3)

MEZZANINES (505) Area limitation (5052) Openness (5054)

Egress (5053) Equipment platforms (5055)

UNLIMITED AREA BUILDINGS (507)

Nonsprinklered one story (5072) Group H occupancies (507 7)

Sprinklered one story (5073) Aircraft paint hangar (5078)

Two story (5074) Group E buildings (5079)

Reduced open space (5075) Motion picture theaters (50710)

Group A-3 buildings (5076) Covered mall buildingsanchor stores (50711)

SPECIAL PROVISIONS (509)

Special condition applicable (5091) Compliance verified

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY (Chapter 4) COVERED MALL BUILDINGS (402) Smoke control (4029)

Egress (4024 40212) Kiosk requirements (40210)

Mall width (4025) Playground structures (40211)

Unlimited area (4026) Emergency voicealarm (40213 40214) Fire separations (402 7)

Plastic signs (40215)Automatic sprinkler system (4028) Fire department access (40216)Standpipe system (40281)

2

HIGH-RISE BUILDINGS (403) OTHER SPECIAL USE AND OCCUPANCY

ATRIUMS (404)

Automatic sprinkler system (4032)

Fire-resistance rating reduction (4033)

Automatic fire detection (4035)

Emergency voicealarm systems (4036)

Fire department communication (403 7)

Fire command center (4038)

Elevators (4039)

Standby power (40310)

Emergency power (403 11)

Stairway doors (403 12)

Smokeproof exit (40313)

Atrium use (4042)

Automatic sprinkler system (4043)

Smoke control (4044)

Enclosure (4045)

Standby power (4046)

Interior finish (404 7)

Travel distance (4048)

Underground structures (405)

Motor-vehicle-related occupancies (406 509)

Group 1-2 (407)

Group 1-3 (408)

Motion picture projection rooms (409)

Stages and platforms (410)

Special amusement buildings (411)

Aircraft-related occupancies (412)

Combustible storage (413)

Hazardous materials (3071 414)

Groups H-1 H-2 H-3 H-4 and H-5 (415)

Application of flammable finishes (416)

Drying rooms (417)

Organic coatings manufacturing (418)

Group 1-1 R-1 R-2 R-3 (419)

Hydrogen cutoff rooms (420)

FIRE PROTECTION (Chapters 6 7 8 9) FIRE-RESISTANCE-RATED CONSTRUCTION (Tables 601 amp 602 and Chapter 7)

Note Entry in D indicates required rating in hours NC indicates noncombustible construction required

Construction classification (602)

COMBUSTIBILITY (6022 6023 6024 6025 603)

Exterior walls

Interior elements

Roof

FIRE-RESISTANCE RATINGS AND FIRE TESTS (703)

Ratings I Combustibility (7032 7034)

Alternative methods (7033 718 720 721)

BUILDING ELEMENTS (Table 601)

D__ D__ D__ D__ D__

Structural frame (714)

Interior bearing walls

Interior nonbearing walls

Floor construction (711)

Roof construction (711)

EXTERIOR WALLS (507 Table 602 704 7066) North East South West

Fire separation distance

Bearing D_D_D_D Non bearing D_D_D_D_

3

EXTERIOR WALLS (continued)

D___

D__ D__

Opening protection (7048 70412 70414)

Vertical fire spread protection (7049 70410)

Parapets (704 11)

FIRE BARRIERS (706)

D___ D__

D__ D___ D__ D___ D__

Shaft enclosures (70631)

Exit enclosuresexit passageway (70632 70633)

Horizontal exits (70634)

Atriums (70635)

Incidental use areas (706 3 6)

Control areas (7063 7)

Mixed occupancy and fire area separations (70638 70639)

INTERIOR FINISHES (Chapter 8)

Smoke development (803 1) Floor finish (804)

Flame spread (803 1) Decorations and trim (806)

Non-textile finish (8032)

FIRE PROTECTION (Chapter 9) AUTOMATIC SPRINKLER SYSTEMS (903) (Where required)

Assembly (A-1 A-2 A-3 A-4 A-5) (90321)

Educational (E) (90322)

FactoryIndustrial (F-1) (90323) High-hazard (H-1 H-2 H-3 H-4 H-5)

(90324) Institutional (1-1 1-2 1-3 1-4)

(4075 90325)

Mercantile (M) (90326) Residential (R) (9032 7) StorageRepair garage (S-1) (90328) Pcrking garages (90329) Windowless story (9032101) Rubbish and linen chutes (9032102) Buildings over 55 ft high (9032103) Incidental uses (5082)

Additional required systems (Table 903213)

International Fire Code (FC 903213) AUTOMATIC SPRINKLER SYSTEMS (903) (Design)

Shop drawings (106111) NFPA 13 system (903311)

NFPA 13R system (903312) NFPA 13D system (903313) Quick-response and residential heads

(90332) Actuation (90334)

Water supplies (90335) Hose threads (90336) Sprinkler monitoring and alarms

(9034 90713)

Also see Fire Code Sprinkler Plan Review Record

4

SHAFTS (707)

D__ D__ OTHER FIRE-RESISTANT CONSTRUCTION

D___ D__ D__

Fire walls (705)

Fire partitions (708)

Smoke barriers (709)

Smoke partitions (710)

Penetrations (712)

Fire-resistant joint systems (713)

Opening protectives (715)

Dampers (716)

Concealed spaces (717)

Thermal- and sound-insulating materials (719)

Exceptions (7072)

Construction (7073- 70714)

ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS (904)

Installation (9043)

Wet-chemical systems (9045)

Dry-chemical systems (904 6)

Foam systems (904 7)

Carbon dioxide systems (9048)

Halon systems (9049)

Clean-agent systems (90410)

Commercial cooking systems (90421 90411)

STANDPIPE SYSTEMS (905)

Installation standards (9052)

Building height (90531)

Group A (90532)

Covered malls (90533)

Stages (90534)

Underground buildings (90535)

Helistopsheliports (9053 6)

Marinasboatyards (9053 7)

Hose connections and locations (9051 9054 9055 9056)

Cabinets (905 7)

Dry standpipes (9058)

Valve supervision (9059)

PORTABLE FIRE EXTINGUISHERS (906)

Required locations- IFC (9061)

FIRE ALARM AND DETECTION SYSTEMS (907)(Where required)

Construction documents (90711)

Assembly (A-1 A-2 A-3 A-4 A-5) (90721)

Business (B) (90722)

Educational (E) (90723)

Factory (F-1 F-2) (90724)

High-hazard (H-1 H-2 H-3 H-4 H-5) (90725)

Institutional (1-1 1-2 1-3 1-4) (90726)

Mercantile (M) (9072 7)

Residential (R-1 R-2) (90728 90729)

Singlemultiple station smoke alarms (907210)

High-rise buildings (907212)

Atriums (907213)

Other buildingsareas (907211 907214- 907223)

FIRE ALARM AND DETECTION SYSTEMS (907)(Design)

Residential smoke alarm power source (9072102)

Residential smoke alarm interconnection (9072103)

LocationPower supplyWiring (9073 - 9075)

ActivationPresignaiZones (9076- 9078)

Alarm notification appliances (9079)

Detectors (907 10 - 907 12)

Monitoring (907 14)

EMERGENCY ALARM SYSTEMS (908)

Detection system applicable (908 1 - 908 6)

SMOKE CONTROL SYSTEMS (909)

Where required (4029 4044 4055 4088 410372 102017 1025621)

Design requirements (909 1 - 9094)

Smoke barriers (9095)

Pressurization method (9096)

Airflow design method (909 7)

Exhaust method (9098)

Design fire (9099)

EquipmentPower (90910 90911)

Detection and control (909 12 - 909 18)

Smokeproof enclosures (90920)

SMOKE AND HEAT VENTS (910)

Requirements (9101- 9103)

Mechanical alternative (9104)

FIRE COMMAND CENTER (911)

Features (9111)

FIRE DEPARTMENT CONNECTIONS (912)

Installation (912 1 - 9125)

5

OCCUPANT NEEDS (Chapters 10 11 12)

MEANS OF EGRESS (Chapter 10)

OCCUPANT LOAD (100411 and Table 100411) CAPACITY OF EGRESS COMPONENTS (10051 and Table 10051)

Location Floor Area

Sqft person

= Occt load

Other acct loads

Total Egress width (inchoccupant)

Stairways ___

Other egress components ___

CAPACITY

Other egress Location Stairways components

NUMBER OF EXITS (10191 10192)

Location Required Shown

6

MEANS OF EGRESS (continued)

GENERAL MEANS OF EGRESS

Design requirements (10032- 10037)

Means of egress illumination (1006)

Exit signs (1011)

Accessible means of egress (1 007)

Means of egress doors (10081-100812)

Special doorsGatesTurnstiles (100813 10082 10083)

EXIT ACCESS

Door number and arrangement (10142 10151 10152)

Common path of egress travel (10143)

Exit access travel distance (10161)

EXITS I EXIT DISCHARGE

ExitsExit doors (1018 1019)

Vertical exit enclosures (1020)

Exit passageways (1021)

OTHER MEANS OF EGRESS

Miscellaneous egress requirements (10153- 10156)

Bleachers (102511)

Assembly exits amp egress (10252- 10255)

ACCESSIBILITY (Chapter 11)

Scoping requirements (1103)

Accessible route (1104)

Accessible entrances (1105)

Parking and passenger loading (1106)

Also see Accessibility Plan Review Record

Door landingsThresholdsArrangement (100814 -10081 7)

Door hardware (100818 100819)

Stairways (1009)

Roof access (100911)

Ramps (1010)

Handrails (1012)

Guards (1013)

Aisles (1 0144)

Egress balconies (10145 10163)

Corridors (1017)

Air movement in corridors (10174)

Horizontal exits (1022)

Exterior exit rampsstairways (1023)

Exit discharge (1024)

Assembly aisles amp features (10256- 102515)

Emergency escape and rescue (1026)

Dwelling units and sleeping units (1107)

Special occupancies (1108)

Features and facilities (1109)

Signage (1110)

7

INTERIOR ENVIRONMENT (Chapter 12)

Ventilation openings (1203) Sound transmission (1207)

Temperature control (1204) Interior space dimensions (1208)

Lighting (1205) Access to unoccupied spaces (1209)

Yards or courts (1206) Surrounding materials (1210 2509)

Also see Mechanical Code Plan Review Record

BUILDING ENVELOPE Chapters 13 14 15) See Energy Conservation Code Plan Review Record

EXTERIOR WALLS (Chapter 14)

Performance requirements (1403) Exterior wall coveringsMCMs (1405 1407)

Materials (1404) Combustible material restrictions (1406)

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (Chapter 15)

Weather protection (1503) Materials (1506)

Flashing (15032 150729 150739 Roof coverings (1507) 150756 150776 150787 150798) Roof insulation (1508)

Performance requirements (1504) Rooftop structures (1509)

Fire classification (1505) Reroofing (1510)

STRUCTURAL SYSTEMS Chapters 16 17 18) STRUCTURAL DESIGN (Chapter 16)

STRUCTURAL DESIGN CALCULATIONS Live load reduction (160311 16079 160710)

Submitted for all structural members Roof live loads (160312 160711)(1061 10611)

Roof snow loads (160313 1608 Chapter 7 ofASCE 7) DESIGN LOADS ON CONSTRUCTION DOCUMENTS Ground snow load pg (16082 72 of(1603) ASCE 7)

If pg gt 10 psf flat-roof snow load pr(73 ofUniformly distributed floor live loads (160311 ASCE 7)Table 1607 1)

If pg gt 1 0 psf snow exposure factor Ce Floor Area Use Loads Shown (Table 7-2 731 of ASCE 7)

If pg gt 10 psf snow load importance factor I (733 Table 7-4 ofASCE 7)

Roof thermal factor Ct (Table 7-3 732 of ASCE 7)

Sloped roof snow load Ps (74 ofASCE 7)

8

DESIGN LOADS (continued)

Wind loads (160314 1609 Chapter 6 of ASCE 7)

Design procedure (612 ofASCE 7)

Basic wind speed (16093 Fig 6-1 of ASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Wind importance factor I (Table 6-1 655 ofASCE 7)

Surface roughnessExposure categories (16094 656 ofASCE 7)

Internal pressure coefficient (Fig 6-5 65111 of ASCE 7)

Component and cladding pressures (6142 6422 65124 ofASCE 7)

Main wind-force resisting system (6141 6421 65122 ofASCE 7)

Earthquake design data (160315 1613 Chapter 11- 13 and 15-23 ofASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Seismic importance factor (1151 Table 115-1 ofASCE 7)

Mapped spectral response acceleration Ss and St (161351 1141 of ASCE 7)

Spectral response coefficients Sos amp Sot (161354 1144 ofASCE 7)

Site class (161352 1142 ofASCE 7)

Seismic design category (161356 116 of ASCE 7)

Basic seismic-force-resisting system (Table 122-1 of ASCE 7)

Response modification coefficient R and deflection amplification factor Cd (Table 122-1 ofASCE 7)

Analysis procedure (126 of ASCE 7)

Design base shear (128 of ASCE 7)

Flood loads (160316 1612)

Flood hazard area (16123)

Elevation of structure (16125)

Other loads

Concentrated loads (16074)

Partition loads (16075)

Impact loads (16078)

Misc loads (Table 16076 160761 16077 160712 160713 1610 1611 2404)

QUALITY ASSURANCE (Chapter 17)

ApprovalsResearch report(s )(1703 170342) Report No____

Statement of special inspections (170411 1705)

Prefabricated items (17042)

Steel construction (17043)

Concrete construction (17044)

Masonry construction (17045)

Wood construction (17046)

Prepared fill and foundations

(1704 7 17048 17049)

Sprayed fire-resistant materials and coatings (170410 170411)

EIFS (170412)

Smoke control (170414)

Seismic resistance (1707)

Structural testingObservations (seismic) (1708 1709)

Testing (other) (1710- 1715)

SOILS AND FOUNDATIONS (Chapter 18)

Soils investigationsReports (18021 18022 18026)

Soil classification (18023)

Excavation grading and fill (1803)

Load-bearing values (1804)

Footings and foundations (1805)

Retaining walls (1806)

Dampproofing and waterproofing (1807)

Foundations (other types) (1808 - 1812)

9

STRUCTURAL MATERIALS (Chapters 19 21 22 23) CONCRETE (Chapter 19)

Plain and reinforced concrete Minimum concrete strength designconstruction standard (Table 190422) specified (19012 1908) Cold weather and hot weather construc-

Construction documents (19014) tion specified (190512 190513)

Slab provisions (1910)

MASONRY (Chapter 21) Design method construction standard Cold weather and hot weather construc-

specified (21012) tion specified (21043 21044)

Construction documents (21013) Seismic design (2106)

Construction materials (2103) Glass unit masonry (2110)

Mortar type (21038) FireplacesHeatersChimneys (2111 2112 2113)

STEEL (Chapter 22) Structural steel designconstruction Steel storage racks (2208)

standard specified (2205) Cold-formed steel designconstruction

Open-web steel joist designconstruction standard specified (2209) standard specified (2206)

Cold-formed steel light-framed design Steel cable structures (2207) construction standard specified (2210)

WOOD (Chapter 23) Design method option used (23012) Fasteners and fastening

(23036 23049 Table 230491)MATERIAL STANDARDS I CONSTRUCTION REQUIREMENTS (2303- 2306) Heavy timber construction (230410)

Lumber (230311) Shear walls and diaphragms (2305 2306) Wood -joists (230312)

CONVENTIONAL LIGHT-FRAME CONSTRUCTION Glue-laminated timbers (230313) (2308) Wood structural panels Limitations satisfied (23082)

(230314 23046 2304 7) WindSeismic requirements (230821

Fiber- hard- ampparticle- boards 230822 230811 230812) (2303 1 5 - 2303 1 7)

Braced walls (23083 230893) Decay and termite protection

Foundation anchorage (230318 230411) (230833 23086)

Structural composite lumber (230319) Floor joists (Tables 23088[1] 23088[2])

Structural log members (2303110) Wall studs (Table 230891) Round timber poles and piles Girders (Tables 230895 and 230896

(2303111) 23087)

Fire-retardant-treated wood (23032) Ceiling joists (Tables 2308102[1] 2308102[2])Hardwood and plywood (23033)

Roof rafters (Tables 2308103[1]shyTrusses (23034) 2308103[6])

Joist hangers and connectors (23035) Roof uplift (2308101)

10

NONSTRUCTURAL MATERIALS (Chapters 24 25 26) GLASS AND GLAZING (Chapter 24)

Sloped glazing and skylights (2405) Safety glazing (2406 2407 2408 2409)

GYPSUM BOARD AND PLASTER (Chapter 25)

Gypsum board materials Plaster (2507 2508 2510- 2513)(2506 Table 25062 Table 25081)

PLASTIC (Chapter 26)

FOAM PLASTIC INSULATION (2603) Protection against termites (26038)

Labeling (26032 260356) Special approval (26039)

Surface-burning characteristics MISCELLANEOUS PLASTICS(26033 260354)

Interior finish and trim (2604)Thermal barrier (26034) Plastic veneer (2605)Exterior wallsRoofs (26035 26036) Light-transmitting plastics (2606- 2611)

BUILDING SERVICES (Chapters 27 28 29 30) ELEVATORS AND CONVEYING SYSTEMS (Chapter 30)

Construction standard specified (30012) Hoistway venting (3004)

Hoistway enclosures (3002) Conveying systems (3005)

Opening protectives (300211) Machine rooms (3006)

Emergency operations (3003)

Also see Electrical (Ch27) Mechanical (Ch28) and Plumbing (Ch29) Plan Review Records

SPECIAL DEVICES AND CONDITIONS (Chapters 31 34) SPECIAL CONSTRUCTION Chapter 31)

Membrane structures (3102) PEDESTRIAN WALKWAYS AND TUNNELS (3104)

Awnings and canopiesMarquees Construction and use (31043 31044)(3105 3106)

Separation (31045 310410)Signs (3107)

Public way (31046)Radio and television towers (3108)

Egress (3104 7- 31049)Swimming pool enclosures (3109)

EXISTING STRUCTURES (Chapter 34)

Additions alterations repairs (3403) Accessibility (3409)

Fire escapes (3404) Compliance alternatives (3410)

Change of occupancy (3406)

11

----------------

BUILDING EVALUATION SUMMARY (Table 34107)

Existing occupancy _______________ Proposed occupancy Year building was constructed ____________ Number of stories ______ Height in feet Type of construction Area per floor Percentage of frontage Corridor wall rating _______________ Completely suppressed Yes ___ No Required door closers _____Yes ___No ___ Compartmentation Yes ___ No Fireresistance rating of vertical opening enclosures Type of HVAC system --------------- serving number of floors Automatic fire detection Yes No ___ type and location Fire alarm system Yes ___ No ___ type --------------------Smoke control Yes No ___ type -------------------Adequate exit routes Yes ___ No Dead ends Yes No ___ Maximum exit access travel distance __________ Elevator controls Yes No Means of egress emergency lighting Yes __ No ___ Mixed occupancies Yes No

Safety Fire Means General parameters safety (FS) of egress (ME) safety (GS)

341061 Building height

341062 Building area

341063 Compartmentation

341064 Tenant and dwelling unit separations

341065 Corridor walls

341066 Vertical openings

341067 HVAC systems

341068 Automatic fire detection

341069 Fire alarm system

3410610 Smoke control

3410611 Means of egress

341012 Dead ends

341013 Max exit access travel distance

3410614 Elevator control

3410615 Means of egress emergency lighting

3410616 Mixed occupancies

3410617 Automatic sprinklers 7 2 =

3410618 Incidental use

Building score -total value

No applicable value to be inserted

BUILDING SAFETY EVALUATION SCORE (Table 34109)

Formula Table 34107 Table 34108 Score Pass Fail

FS-MFS ~0 (FS) (MFS) = ME-MME 2 0 (ME) (MME) = GS-MGS gt 0 (GS) (MGS) =

FS = Fire Safety MFS = Mandatory Fire Safety ME = Means of Egress MME = Mandatory Means of Egress GS = General Safety MGS = Mandatory General Safety

APPENDICES A- J

Appendices adopted (10121) Compliance verified

12

Page 2: NOTES: N.R. N.A.- Not applicable ADMINISTRATION {Chapter 1) · Mixed Occupancy (508.3) Accessory occupancies (508.3.1) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to

CASE 2- SEPARATED MIXED OCCUPANCIES (50833)

Using Table 503 identify the allowable height and area of each of the separated occupancies within the building Construc-tion types that provide for each story of the building tabular areas (as modified by Section 506) which result in a sum of the ratios of 100 or less and allowable heights (as modified by Section 504) equal to or greater than the actual height of the occupancy are permitted

Allow tab area A (Table 503)

Actual Adjusted Actual Allowable Story Group floor area floor area height height

ft2 ft2 ft stories ft stories ft2 tt2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories

t ( fl ) Area ra 10 smg e 1 oor = LJ Adjusted floor area =---+ + + tOO

Adjusted floor area= actual floor area_ conversion factor

CHECK ALLOWABLE AREA (5064)

Total area ratio (all floors)= Permitted types of construction _________

Two-story buildings (Total area ratio 2) Type of construction assumed for review (60211)

Three or more story buildings Compliance verified (Mixed Occ Separated) ____ (Total area ratio 3)

MEZZANINES (505) Area limitation (5052) Openness (5054)

Egress (5053) Equipment platforms (5055)

UNLIMITED AREA BUILDINGS (507)

Nonsprinklered one story (5072) Group H occupancies (507 7)

Sprinklered one story (5073) Aircraft paint hangar (5078)

Two story (5074) Group E buildings (5079)

Reduced open space (5075) Motion picture theaters (50710)

Group A-3 buildings (5076) Covered mall buildingsanchor stores (50711)

SPECIAL PROVISIONS (509)

Special condition applicable (5091) Compliance verified

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY (Chapter 4) COVERED MALL BUILDINGS (402) Smoke control (4029)

Egress (4024 40212) Kiosk requirements (40210)

Mall width (4025) Playground structures (40211)

Unlimited area (4026) Emergency voicealarm (40213 40214) Fire separations (402 7)

Plastic signs (40215)Automatic sprinkler system (4028) Fire department access (40216)Standpipe system (40281)

2

HIGH-RISE BUILDINGS (403) OTHER SPECIAL USE AND OCCUPANCY

ATRIUMS (404)

Automatic sprinkler system (4032)

Fire-resistance rating reduction (4033)

Automatic fire detection (4035)

Emergency voicealarm systems (4036)

Fire department communication (403 7)

Fire command center (4038)

Elevators (4039)

Standby power (40310)

Emergency power (403 11)

Stairway doors (403 12)

Smokeproof exit (40313)

Atrium use (4042)

Automatic sprinkler system (4043)

Smoke control (4044)

Enclosure (4045)

Standby power (4046)

Interior finish (404 7)

Travel distance (4048)

Underground structures (405)

Motor-vehicle-related occupancies (406 509)

Group 1-2 (407)

Group 1-3 (408)

Motion picture projection rooms (409)

Stages and platforms (410)

Special amusement buildings (411)

Aircraft-related occupancies (412)

Combustible storage (413)

Hazardous materials (3071 414)

Groups H-1 H-2 H-3 H-4 and H-5 (415)

Application of flammable finishes (416)

Drying rooms (417)

Organic coatings manufacturing (418)

Group 1-1 R-1 R-2 R-3 (419)

Hydrogen cutoff rooms (420)

FIRE PROTECTION (Chapters 6 7 8 9) FIRE-RESISTANCE-RATED CONSTRUCTION (Tables 601 amp 602 and Chapter 7)

Note Entry in D indicates required rating in hours NC indicates noncombustible construction required

Construction classification (602)

COMBUSTIBILITY (6022 6023 6024 6025 603)

Exterior walls

Interior elements

Roof

FIRE-RESISTANCE RATINGS AND FIRE TESTS (703)

Ratings I Combustibility (7032 7034)

Alternative methods (7033 718 720 721)

BUILDING ELEMENTS (Table 601)

D__ D__ D__ D__ D__

Structural frame (714)

Interior bearing walls

Interior nonbearing walls

Floor construction (711)

Roof construction (711)

EXTERIOR WALLS (507 Table 602 704 7066) North East South West

Fire separation distance

Bearing D_D_D_D Non bearing D_D_D_D_

3

EXTERIOR WALLS (continued)

D___

D__ D__

Opening protection (7048 70412 70414)

Vertical fire spread protection (7049 70410)

Parapets (704 11)

FIRE BARRIERS (706)

D___ D__

D__ D___ D__ D___ D__

Shaft enclosures (70631)

Exit enclosuresexit passageway (70632 70633)

Horizontal exits (70634)

Atriums (70635)

Incidental use areas (706 3 6)

Control areas (7063 7)

Mixed occupancy and fire area separations (70638 70639)

INTERIOR FINISHES (Chapter 8)

Smoke development (803 1) Floor finish (804)

Flame spread (803 1) Decorations and trim (806)

Non-textile finish (8032)

FIRE PROTECTION (Chapter 9) AUTOMATIC SPRINKLER SYSTEMS (903) (Where required)

Assembly (A-1 A-2 A-3 A-4 A-5) (90321)

Educational (E) (90322)

FactoryIndustrial (F-1) (90323) High-hazard (H-1 H-2 H-3 H-4 H-5)

(90324) Institutional (1-1 1-2 1-3 1-4)

(4075 90325)

Mercantile (M) (90326) Residential (R) (9032 7) StorageRepair garage (S-1) (90328) Pcrking garages (90329) Windowless story (9032101) Rubbish and linen chutes (9032102) Buildings over 55 ft high (9032103) Incidental uses (5082)

Additional required systems (Table 903213)

International Fire Code (FC 903213) AUTOMATIC SPRINKLER SYSTEMS (903) (Design)

Shop drawings (106111) NFPA 13 system (903311)

NFPA 13R system (903312) NFPA 13D system (903313) Quick-response and residential heads

(90332) Actuation (90334)

Water supplies (90335) Hose threads (90336) Sprinkler monitoring and alarms

(9034 90713)

Also see Fire Code Sprinkler Plan Review Record

4

SHAFTS (707)

D__ D__ OTHER FIRE-RESISTANT CONSTRUCTION

D___ D__ D__

Fire walls (705)

Fire partitions (708)

Smoke barriers (709)

Smoke partitions (710)

Penetrations (712)

Fire-resistant joint systems (713)

Opening protectives (715)

Dampers (716)

Concealed spaces (717)

Thermal- and sound-insulating materials (719)

Exceptions (7072)

Construction (7073- 70714)

ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS (904)

Installation (9043)

Wet-chemical systems (9045)

Dry-chemical systems (904 6)

Foam systems (904 7)

Carbon dioxide systems (9048)

Halon systems (9049)

Clean-agent systems (90410)

Commercial cooking systems (90421 90411)

STANDPIPE SYSTEMS (905)

Installation standards (9052)

Building height (90531)

Group A (90532)

Covered malls (90533)

Stages (90534)

Underground buildings (90535)

Helistopsheliports (9053 6)

Marinasboatyards (9053 7)

Hose connections and locations (9051 9054 9055 9056)

Cabinets (905 7)

Dry standpipes (9058)

Valve supervision (9059)

PORTABLE FIRE EXTINGUISHERS (906)

Required locations- IFC (9061)

FIRE ALARM AND DETECTION SYSTEMS (907)(Where required)

Construction documents (90711)

Assembly (A-1 A-2 A-3 A-4 A-5) (90721)

Business (B) (90722)

Educational (E) (90723)

Factory (F-1 F-2) (90724)

High-hazard (H-1 H-2 H-3 H-4 H-5) (90725)

Institutional (1-1 1-2 1-3 1-4) (90726)

Mercantile (M) (9072 7)

Residential (R-1 R-2) (90728 90729)

Singlemultiple station smoke alarms (907210)

High-rise buildings (907212)

Atriums (907213)

Other buildingsareas (907211 907214- 907223)

FIRE ALARM AND DETECTION SYSTEMS (907)(Design)

Residential smoke alarm power source (9072102)

Residential smoke alarm interconnection (9072103)

LocationPower supplyWiring (9073 - 9075)

ActivationPresignaiZones (9076- 9078)

Alarm notification appliances (9079)

Detectors (907 10 - 907 12)

Monitoring (907 14)

EMERGENCY ALARM SYSTEMS (908)

Detection system applicable (908 1 - 908 6)

SMOKE CONTROL SYSTEMS (909)

Where required (4029 4044 4055 4088 410372 102017 1025621)

Design requirements (909 1 - 9094)

Smoke barriers (9095)

Pressurization method (9096)

Airflow design method (909 7)

Exhaust method (9098)

Design fire (9099)

EquipmentPower (90910 90911)

Detection and control (909 12 - 909 18)

Smokeproof enclosures (90920)

SMOKE AND HEAT VENTS (910)

Requirements (9101- 9103)

Mechanical alternative (9104)

FIRE COMMAND CENTER (911)

Features (9111)

FIRE DEPARTMENT CONNECTIONS (912)

Installation (912 1 - 9125)

5

OCCUPANT NEEDS (Chapters 10 11 12)

MEANS OF EGRESS (Chapter 10)

OCCUPANT LOAD (100411 and Table 100411) CAPACITY OF EGRESS COMPONENTS (10051 and Table 10051)

Location Floor Area

Sqft person

= Occt load

Other acct loads

Total Egress width (inchoccupant)

Stairways ___

Other egress components ___

CAPACITY

Other egress Location Stairways components

NUMBER OF EXITS (10191 10192)

Location Required Shown

6

MEANS OF EGRESS (continued)

GENERAL MEANS OF EGRESS

Design requirements (10032- 10037)

Means of egress illumination (1006)

Exit signs (1011)

Accessible means of egress (1 007)

Means of egress doors (10081-100812)

Special doorsGatesTurnstiles (100813 10082 10083)

EXIT ACCESS

Door number and arrangement (10142 10151 10152)

Common path of egress travel (10143)

Exit access travel distance (10161)

EXITS I EXIT DISCHARGE

ExitsExit doors (1018 1019)

Vertical exit enclosures (1020)

Exit passageways (1021)

OTHER MEANS OF EGRESS

Miscellaneous egress requirements (10153- 10156)

Bleachers (102511)

Assembly exits amp egress (10252- 10255)

ACCESSIBILITY (Chapter 11)

Scoping requirements (1103)

Accessible route (1104)

Accessible entrances (1105)

Parking and passenger loading (1106)

Also see Accessibility Plan Review Record

Door landingsThresholdsArrangement (100814 -10081 7)

Door hardware (100818 100819)

Stairways (1009)

Roof access (100911)

Ramps (1010)

Handrails (1012)

Guards (1013)

Aisles (1 0144)

Egress balconies (10145 10163)

Corridors (1017)

Air movement in corridors (10174)

Horizontal exits (1022)

Exterior exit rampsstairways (1023)

Exit discharge (1024)

Assembly aisles amp features (10256- 102515)

Emergency escape and rescue (1026)

Dwelling units and sleeping units (1107)

Special occupancies (1108)

Features and facilities (1109)

Signage (1110)

7

INTERIOR ENVIRONMENT (Chapter 12)

Ventilation openings (1203) Sound transmission (1207)

Temperature control (1204) Interior space dimensions (1208)

Lighting (1205) Access to unoccupied spaces (1209)

Yards or courts (1206) Surrounding materials (1210 2509)

Also see Mechanical Code Plan Review Record

BUILDING ENVELOPE Chapters 13 14 15) See Energy Conservation Code Plan Review Record

EXTERIOR WALLS (Chapter 14)

Performance requirements (1403) Exterior wall coveringsMCMs (1405 1407)

Materials (1404) Combustible material restrictions (1406)

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (Chapter 15)

Weather protection (1503) Materials (1506)

Flashing (15032 150729 150739 Roof coverings (1507) 150756 150776 150787 150798) Roof insulation (1508)

Performance requirements (1504) Rooftop structures (1509)

Fire classification (1505) Reroofing (1510)

STRUCTURAL SYSTEMS Chapters 16 17 18) STRUCTURAL DESIGN (Chapter 16)

STRUCTURAL DESIGN CALCULATIONS Live load reduction (160311 16079 160710)

Submitted for all structural members Roof live loads (160312 160711)(1061 10611)

Roof snow loads (160313 1608 Chapter 7 ofASCE 7) DESIGN LOADS ON CONSTRUCTION DOCUMENTS Ground snow load pg (16082 72 of(1603) ASCE 7)

If pg gt 10 psf flat-roof snow load pr(73 ofUniformly distributed floor live loads (160311 ASCE 7)Table 1607 1)

If pg gt 1 0 psf snow exposure factor Ce Floor Area Use Loads Shown (Table 7-2 731 of ASCE 7)

If pg gt 10 psf snow load importance factor I (733 Table 7-4 ofASCE 7)

Roof thermal factor Ct (Table 7-3 732 of ASCE 7)

Sloped roof snow load Ps (74 ofASCE 7)

8

DESIGN LOADS (continued)

Wind loads (160314 1609 Chapter 6 of ASCE 7)

Design procedure (612 ofASCE 7)

Basic wind speed (16093 Fig 6-1 of ASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Wind importance factor I (Table 6-1 655 ofASCE 7)

Surface roughnessExposure categories (16094 656 ofASCE 7)

Internal pressure coefficient (Fig 6-5 65111 of ASCE 7)

Component and cladding pressures (6142 6422 65124 ofASCE 7)

Main wind-force resisting system (6141 6421 65122 ofASCE 7)

Earthquake design data (160315 1613 Chapter 11- 13 and 15-23 ofASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Seismic importance factor (1151 Table 115-1 ofASCE 7)

Mapped spectral response acceleration Ss and St (161351 1141 of ASCE 7)

Spectral response coefficients Sos amp Sot (161354 1144 ofASCE 7)

Site class (161352 1142 ofASCE 7)

Seismic design category (161356 116 of ASCE 7)

Basic seismic-force-resisting system (Table 122-1 of ASCE 7)

Response modification coefficient R and deflection amplification factor Cd (Table 122-1 ofASCE 7)

Analysis procedure (126 of ASCE 7)

Design base shear (128 of ASCE 7)

Flood loads (160316 1612)

Flood hazard area (16123)

Elevation of structure (16125)

Other loads

Concentrated loads (16074)

Partition loads (16075)

Impact loads (16078)

Misc loads (Table 16076 160761 16077 160712 160713 1610 1611 2404)

QUALITY ASSURANCE (Chapter 17)

ApprovalsResearch report(s )(1703 170342) Report No____

Statement of special inspections (170411 1705)

Prefabricated items (17042)

Steel construction (17043)

Concrete construction (17044)

Masonry construction (17045)

Wood construction (17046)

Prepared fill and foundations

(1704 7 17048 17049)

Sprayed fire-resistant materials and coatings (170410 170411)

EIFS (170412)

Smoke control (170414)

Seismic resistance (1707)

Structural testingObservations (seismic) (1708 1709)

Testing (other) (1710- 1715)

SOILS AND FOUNDATIONS (Chapter 18)

Soils investigationsReports (18021 18022 18026)

Soil classification (18023)

Excavation grading and fill (1803)

Load-bearing values (1804)

Footings and foundations (1805)

Retaining walls (1806)

Dampproofing and waterproofing (1807)

Foundations (other types) (1808 - 1812)

9

STRUCTURAL MATERIALS (Chapters 19 21 22 23) CONCRETE (Chapter 19)

Plain and reinforced concrete Minimum concrete strength designconstruction standard (Table 190422) specified (19012 1908) Cold weather and hot weather construc-

Construction documents (19014) tion specified (190512 190513)

Slab provisions (1910)

MASONRY (Chapter 21) Design method construction standard Cold weather and hot weather construc-

specified (21012) tion specified (21043 21044)

Construction documents (21013) Seismic design (2106)

Construction materials (2103) Glass unit masonry (2110)

Mortar type (21038) FireplacesHeatersChimneys (2111 2112 2113)

STEEL (Chapter 22) Structural steel designconstruction Steel storage racks (2208)

standard specified (2205) Cold-formed steel designconstruction

Open-web steel joist designconstruction standard specified (2209) standard specified (2206)

Cold-formed steel light-framed design Steel cable structures (2207) construction standard specified (2210)

WOOD (Chapter 23) Design method option used (23012) Fasteners and fastening

(23036 23049 Table 230491)MATERIAL STANDARDS I CONSTRUCTION REQUIREMENTS (2303- 2306) Heavy timber construction (230410)

Lumber (230311) Shear walls and diaphragms (2305 2306) Wood -joists (230312)

CONVENTIONAL LIGHT-FRAME CONSTRUCTION Glue-laminated timbers (230313) (2308) Wood structural panels Limitations satisfied (23082)

(230314 23046 2304 7) WindSeismic requirements (230821

Fiber- hard- ampparticle- boards 230822 230811 230812) (2303 1 5 - 2303 1 7)

Braced walls (23083 230893) Decay and termite protection

Foundation anchorage (230318 230411) (230833 23086)

Structural composite lumber (230319) Floor joists (Tables 23088[1] 23088[2])

Structural log members (2303110) Wall studs (Table 230891) Round timber poles and piles Girders (Tables 230895 and 230896

(2303111) 23087)

Fire-retardant-treated wood (23032) Ceiling joists (Tables 2308102[1] 2308102[2])Hardwood and plywood (23033)

Roof rafters (Tables 2308103[1]shyTrusses (23034) 2308103[6])

Joist hangers and connectors (23035) Roof uplift (2308101)

10

NONSTRUCTURAL MATERIALS (Chapters 24 25 26) GLASS AND GLAZING (Chapter 24)

Sloped glazing and skylights (2405) Safety glazing (2406 2407 2408 2409)

GYPSUM BOARD AND PLASTER (Chapter 25)

Gypsum board materials Plaster (2507 2508 2510- 2513)(2506 Table 25062 Table 25081)

PLASTIC (Chapter 26)

FOAM PLASTIC INSULATION (2603) Protection against termites (26038)

Labeling (26032 260356) Special approval (26039)

Surface-burning characteristics MISCELLANEOUS PLASTICS(26033 260354)

Interior finish and trim (2604)Thermal barrier (26034) Plastic veneer (2605)Exterior wallsRoofs (26035 26036) Light-transmitting plastics (2606- 2611)

BUILDING SERVICES (Chapters 27 28 29 30) ELEVATORS AND CONVEYING SYSTEMS (Chapter 30)

Construction standard specified (30012) Hoistway venting (3004)

Hoistway enclosures (3002) Conveying systems (3005)

Opening protectives (300211) Machine rooms (3006)

Emergency operations (3003)

Also see Electrical (Ch27) Mechanical (Ch28) and Plumbing (Ch29) Plan Review Records

SPECIAL DEVICES AND CONDITIONS (Chapters 31 34) SPECIAL CONSTRUCTION Chapter 31)

Membrane structures (3102) PEDESTRIAN WALKWAYS AND TUNNELS (3104)

Awnings and canopiesMarquees Construction and use (31043 31044)(3105 3106)

Separation (31045 310410)Signs (3107)

Public way (31046)Radio and television towers (3108)

Egress (3104 7- 31049)Swimming pool enclosures (3109)

EXISTING STRUCTURES (Chapter 34)

Additions alterations repairs (3403) Accessibility (3409)

Fire escapes (3404) Compliance alternatives (3410)

Change of occupancy (3406)

11

----------------

BUILDING EVALUATION SUMMARY (Table 34107)

Existing occupancy _______________ Proposed occupancy Year building was constructed ____________ Number of stories ______ Height in feet Type of construction Area per floor Percentage of frontage Corridor wall rating _______________ Completely suppressed Yes ___ No Required door closers _____Yes ___No ___ Compartmentation Yes ___ No Fireresistance rating of vertical opening enclosures Type of HVAC system --------------- serving number of floors Automatic fire detection Yes No ___ type and location Fire alarm system Yes ___ No ___ type --------------------Smoke control Yes No ___ type -------------------Adequate exit routes Yes ___ No Dead ends Yes No ___ Maximum exit access travel distance __________ Elevator controls Yes No Means of egress emergency lighting Yes __ No ___ Mixed occupancies Yes No

Safety Fire Means General parameters safety (FS) of egress (ME) safety (GS)

341061 Building height

341062 Building area

341063 Compartmentation

341064 Tenant and dwelling unit separations

341065 Corridor walls

341066 Vertical openings

341067 HVAC systems

341068 Automatic fire detection

341069 Fire alarm system

3410610 Smoke control

3410611 Means of egress

341012 Dead ends

341013 Max exit access travel distance

3410614 Elevator control

3410615 Means of egress emergency lighting

3410616 Mixed occupancies

3410617 Automatic sprinklers 7 2 =

3410618 Incidental use

Building score -total value

No applicable value to be inserted

BUILDING SAFETY EVALUATION SCORE (Table 34109)

Formula Table 34107 Table 34108 Score Pass Fail

FS-MFS ~0 (FS) (MFS) = ME-MME 2 0 (ME) (MME) = GS-MGS gt 0 (GS) (MGS) =

FS = Fire Safety MFS = Mandatory Fire Safety ME = Means of Egress MME = Mandatory Means of Egress GS = General Safety MGS = Mandatory General Safety

APPENDICES A- J

Appendices adopted (10121) Compliance verified

12

Page 3: NOTES: N.R. N.A.- Not applicable ADMINISTRATION {Chapter 1) · Mixed Occupancy (508.3) Accessory occupancies (508.3.1) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to

HIGH-RISE BUILDINGS (403) OTHER SPECIAL USE AND OCCUPANCY

ATRIUMS (404)

Automatic sprinkler system (4032)

Fire-resistance rating reduction (4033)

Automatic fire detection (4035)

Emergency voicealarm systems (4036)

Fire department communication (403 7)

Fire command center (4038)

Elevators (4039)

Standby power (40310)

Emergency power (403 11)

Stairway doors (403 12)

Smokeproof exit (40313)

Atrium use (4042)

Automatic sprinkler system (4043)

Smoke control (4044)

Enclosure (4045)

Standby power (4046)

Interior finish (404 7)

Travel distance (4048)

Underground structures (405)

Motor-vehicle-related occupancies (406 509)

Group 1-2 (407)

Group 1-3 (408)

Motion picture projection rooms (409)

Stages and platforms (410)

Special amusement buildings (411)

Aircraft-related occupancies (412)

Combustible storage (413)

Hazardous materials (3071 414)

Groups H-1 H-2 H-3 H-4 and H-5 (415)

Application of flammable finishes (416)

Drying rooms (417)

Organic coatings manufacturing (418)

Group 1-1 R-1 R-2 R-3 (419)

Hydrogen cutoff rooms (420)

FIRE PROTECTION (Chapters 6 7 8 9) FIRE-RESISTANCE-RATED CONSTRUCTION (Tables 601 amp 602 and Chapter 7)

Note Entry in D indicates required rating in hours NC indicates noncombustible construction required

Construction classification (602)

COMBUSTIBILITY (6022 6023 6024 6025 603)

Exterior walls

Interior elements

Roof

FIRE-RESISTANCE RATINGS AND FIRE TESTS (703)

Ratings I Combustibility (7032 7034)

Alternative methods (7033 718 720 721)

BUILDING ELEMENTS (Table 601)

D__ D__ D__ D__ D__

Structural frame (714)

Interior bearing walls

Interior nonbearing walls

Floor construction (711)

Roof construction (711)

EXTERIOR WALLS (507 Table 602 704 7066) North East South West

Fire separation distance

Bearing D_D_D_D Non bearing D_D_D_D_

3

EXTERIOR WALLS (continued)

D___

D__ D__

Opening protection (7048 70412 70414)

Vertical fire spread protection (7049 70410)

Parapets (704 11)

FIRE BARRIERS (706)

D___ D__

D__ D___ D__ D___ D__

Shaft enclosures (70631)

Exit enclosuresexit passageway (70632 70633)

Horizontal exits (70634)

Atriums (70635)

Incidental use areas (706 3 6)

Control areas (7063 7)

Mixed occupancy and fire area separations (70638 70639)

INTERIOR FINISHES (Chapter 8)

Smoke development (803 1) Floor finish (804)

Flame spread (803 1) Decorations and trim (806)

Non-textile finish (8032)

FIRE PROTECTION (Chapter 9) AUTOMATIC SPRINKLER SYSTEMS (903) (Where required)

Assembly (A-1 A-2 A-3 A-4 A-5) (90321)

Educational (E) (90322)

FactoryIndustrial (F-1) (90323) High-hazard (H-1 H-2 H-3 H-4 H-5)

(90324) Institutional (1-1 1-2 1-3 1-4)

(4075 90325)

Mercantile (M) (90326) Residential (R) (9032 7) StorageRepair garage (S-1) (90328) Pcrking garages (90329) Windowless story (9032101) Rubbish and linen chutes (9032102) Buildings over 55 ft high (9032103) Incidental uses (5082)

Additional required systems (Table 903213)

International Fire Code (FC 903213) AUTOMATIC SPRINKLER SYSTEMS (903) (Design)

Shop drawings (106111) NFPA 13 system (903311)

NFPA 13R system (903312) NFPA 13D system (903313) Quick-response and residential heads

(90332) Actuation (90334)

Water supplies (90335) Hose threads (90336) Sprinkler monitoring and alarms

(9034 90713)

Also see Fire Code Sprinkler Plan Review Record

4

SHAFTS (707)

D__ D__ OTHER FIRE-RESISTANT CONSTRUCTION

D___ D__ D__

Fire walls (705)

Fire partitions (708)

Smoke barriers (709)

Smoke partitions (710)

Penetrations (712)

Fire-resistant joint systems (713)

Opening protectives (715)

Dampers (716)

Concealed spaces (717)

Thermal- and sound-insulating materials (719)

Exceptions (7072)

Construction (7073- 70714)

ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS (904)

Installation (9043)

Wet-chemical systems (9045)

Dry-chemical systems (904 6)

Foam systems (904 7)

Carbon dioxide systems (9048)

Halon systems (9049)

Clean-agent systems (90410)

Commercial cooking systems (90421 90411)

STANDPIPE SYSTEMS (905)

Installation standards (9052)

Building height (90531)

Group A (90532)

Covered malls (90533)

Stages (90534)

Underground buildings (90535)

Helistopsheliports (9053 6)

Marinasboatyards (9053 7)

Hose connections and locations (9051 9054 9055 9056)

Cabinets (905 7)

Dry standpipes (9058)

Valve supervision (9059)

PORTABLE FIRE EXTINGUISHERS (906)

Required locations- IFC (9061)

FIRE ALARM AND DETECTION SYSTEMS (907)(Where required)

Construction documents (90711)

Assembly (A-1 A-2 A-3 A-4 A-5) (90721)

Business (B) (90722)

Educational (E) (90723)

Factory (F-1 F-2) (90724)

High-hazard (H-1 H-2 H-3 H-4 H-5) (90725)

Institutional (1-1 1-2 1-3 1-4) (90726)

Mercantile (M) (9072 7)

Residential (R-1 R-2) (90728 90729)

Singlemultiple station smoke alarms (907210)

High-rise buildings (907212)

Atriums (907213)

Other buildingsareas (907211 907214- 907223)

FIRE ALARM AND DETECTION SYSTEMS (907)(Design)

Residential smoke alarm power source (9072102)

Residential smoke alarm interconnection (9072103)

LocationPower supplyWiring (9073 - 9075)

ActivationPresignaiZones (9076- 9078)

Alarm notification appliances (9079)

Detectors (907 10 - 907 12)

Monitoring (907 14)

EMERGENCY ALARM SYSTEMS (908)

Detection system applicable (908 1 - 908 6)

SMOKE CONTROL SYSTEMS (909)

Where required (4029 4044 4055 4088 410372 102017 1025621)

Design requirements (909 1 - 9094)

Smoke barriers (9095)

Pressurization method (9096)

Airflow design method (909 7)

Exhaust method (9098)

Design fire (9099)

EquipmentPower (90910 90911)

Detection and control (909 12 - 909 18)

Smokeproof enclosures (90920)

SMOKE AND HEAT VENTS (910)

Requirements (9101- 9103)

Mechanical alternative (9104)

FIRE COMMAND CENTER (911)

Features (9111)

FIRE DEPARTMENT CONNECTIONS (912)

Installation (912 1 - 9125)

5

OCCUPANT NEEDS (Chapters 10 11 12)

MEANS OF EGRESS (Chapter 10)

OCCUPANT LOAD (100411 and Table 100411) CAPACITY OF EGRESS COMPONENTS (10051 and Table 10051)

Location Floor Area

Sqft person

= Occt load

Other acct loads

Total Egress width (inchoccupant)

Stairways ___

Other egress components ___

CAPACITY

Other egress Location Stairways components

NUMBER OF EXITS (10191 10192)

Location Required Shown

6

MEANS OF EGRESS (continued)

GENERAL MEANS OF EGRESS

Design requirements (10032- 10037)

Means of egress illumination (1006)

Exit signs (1011)

Accessible means of egress (1 007)

Means of egress doors (10081-100812)

Special doorsGatesTurnstiles (100813 10082 10083)

EXIT ACCESS

Door number and arrangement (10142 10151 10152)

Common path of egress travel (10143)

Exit access travel distance (10161)

EXITS I EXIT DISCHARGE

ExitsExit doors (1018 1019)

Vertical exit enclosures (1020)

Exit passageways (1021)

OTHER MEANS OF EGRESS

Miscellaneous egress requirements (10153- 10156)

Bleachers (102511)

Assembly exits amp egress (10252- 10255)

ACCESSIBILITY (Chapter 11)

Scoping requirements (1103)

Accessible route (1104)

Accessible entrances (1105)

Parking and passenger loading (1106)

Also see Accessibility Plan Review Record

Door landingsThresholdsArrangement (100814 -10081 7)

Door hardware (100818 100819)

Stairways (1009)

Roof access (100911)

Ramps (1010)

Handrails (1012)

Guards (1013)

Aisles (1 0144)

Egress balconies (10145 10163)

Corridors (1017)

Air movement in corridors (10174)

Horizontal exits (1022)

Exterior exit rampsstairways (1023)

Exit discharge (1024)

Assembly aisles amp features (10256- 102515)

Emergency escape and rescue (1026)

Dwelling units and sleeping units (1107)

Special occupancies (1108)

Features and facilities (1109)

Signage (1110)

7

INTERIOR ENVIRONMENT (Chapter 12)

Ventilation openings (1203) Sound transmission (1207)

Temperature control (1204) Interior space dimensions (1208)

Lighting (1205) Access to unoccupied spaces (1209)

Yards or courts (1206) Surrounding materials (1210 2509)

Also see Mechanical Code Plan Review Record

BUILDING ENVELOPE Chapters 13 14 15) See Energy Conservation Code Plan Review Record

EXTERIOR WALLS (Chapter 14)

Performance requirements (1403) Exterior wall coveringsMCMs (1405 1407)

Materials (1404) Combustible material restrictions (1406)

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (Chapter 15)

Weather protection (1503) Materials (1506)

Flashing (15032 150729 150739 Roof coverings (1507) 150756 150776 150787 150798) Roof insulation (1508)

Performance requirements (1504) Rooftop structures (1509)

Fire classification (1505) Reroofing (1510)

STRUCTURAL SYSTEMS Chapters 16 17 18) STRUCTURAL DESIGN (Chapter 16)

STRUCTURAL DESIGN CALCULATIONS Live load reduction (160311 16079 160710)

Submitted for all structural members Roof live loads (160312 160711)(1061 10611)

Roof snow loads (160313 1608 Chapter 7 ofASCE 7) DESIGN LOADS ON CONSTRUCTION DOCUMENTS Ground snow load pg (16082 72 of(1603) ASCE 7)

If pg gt 10 psf flat-roof snow load pr(73 ofUniformly distributed floor live loads (160311 ASCE 7)Table 1607 1)

If pg gt 1 0 psf snow exposure factor Ce Floor Area Use Loads Shown (Table 7-2 731 of ASCE 7)

If pg gt 10 psf snow load importance factor I (733 Table 7-4 ofASCE 7)

Roof thermal factor Ct (Table 7-3 732 of ASCE 7)

Sloped roof snow load Ps (74 ofASCE 7)

8

DESIGN LOADS (continued)

Wind loads (160314 1609 Chapter 6 of ASCE 7)

Design procedure (612 ofASCE 7)

Basic wind speed (16093 Fig 6-1 of ASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Wind importance factor I (Table 6-1 655 ofASCE 7)

Surface roughnessExposure categories (16094 656 ofASCE 7)

Internal pressure coefficient (Fig 6-5 65111 of ASCE 7)

Component and cladding pressures (6142 6422 65124 ofASCE 7)

Main wind-force resisting system (6141 6421 65122 ofASCE 7)

Earthquake design data (160315 1613 Chapter 11- 13 and 15-23 ofASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Seismic importance factor (1151 Table 115-1 ofASCE 7)

Mapped spectral response acceleration Ss and St (161351 1141 of ASCE 7)

Spectral response coefficients Sos amp Sot (161354 1144 ofASCE 7)

Site class (161352 1142 ofASCE 7)

Seismic design category (161356 116 of ASCE 7)

Basic seismic-force-resisting system (Table 122-1 of ASCE 7)

Response modification coefficient R and deflection amplification factor Cd (Table 122-1 ofASCE 7)

Analysis procedure (126 of ASCE 7)

Design base shear (128 of ASCE 7)

Flood loads (160316 1612)

Flood hazard area (16123)

Elevation of structure (16125)

Other loads

Concentrated loads (16074)

Partition loads (16075)

Impact loads (16078)

Misc loads (Table 16076 160761 16077 160712 160713 1610 1611 2404)

QUALITY ASSURANCE (Chapter 17)

ApprovalsResearch report(s )(1703 170342) Report No____

Statement of special inspections (170411 1705)

Prefabricated items (17042)

Steel construction (17043)

Concrete construction (17044)

Masonry construction (17045)

Wood construction (17046)

Prepared fill and foundations

(1704 7 17048 17049)

Sprayed fire-resistant materials and coatings (170410 170411)

EIFS (170412)

Smoke control (170414)

Seismic resistance (1707)

Structural testingObservations (seismic) (1708 1709)

Testing (other) (1710- 1715)

SOILS AND FOUNDATIONS (Chapter 18)

Soils investigationsReports (18021 18022 18026)

Soil classification (18023)

Excavation grading and fill (1803)

Load-bearing values (1804)

Footings and foundations (1805)

Retaining walls (1806)

Dampproofing and waterproofing (1807)

Foundations (other types) (1808 - 1812)

9

STRUCTURAL MATERIALS (Chapters 19 21 22 23) CONCRETE (Chapter 19)

Plain and reinforced concrete Minimum concrete strength designconstruction standard (Table 190422) specified (19012 1908) Cold weather and hot weather construc-

Construction documents (19014) tion specified (190512 190513)

Slab provisions (1910)

MASONRY (Chapter 21) Design method construction standard Cold weather and hot weather construc-

specified (21012) tion specified (21043 21044)

Construction documents (21013) Seismic design (2106)

Construction materials (2103) Glass unit masonry (2110)

Mortar type (21038) FireplacesHeatersChimneys (2111 2112 2113)

STEEL (Chapter 22) Structural steel designconstruction Steel storage racks (2208)

standard specified (2205) Cold-formed steel designconstruction

Open-web steel joist designconstruction standard specified (2209) standard specified (2206)

Cold-formed steel light-framed design Steel cable structures (2207) construction standard specified (2210)

WOOD (Chapter 23) Design method option used (23012) Fasteners and fastening

(23036 23049 Table 230491)MATERIAL STANDARDS I CONSTRUCTION REQUIREMENTS (2303- 2306) Heavy timber construction (230410)

Lumber (230311) Shear walls and diaphragms (2305 2306) Wood -joists (230312)

CONVENTIONAL LIGHT-FRAME CONSTRUCTION Glue-laminated timbers (230313) (2308) Wood structural panels Limitations satisfied (23082)

(230314 23046 2304 7) WindSeismic requirements (230821

Fiber- hard- ampparticle- boards 230822 230811 230812) (2303 1 5 - 2303 1 7)

Braced walls (23083 230893) Decay and termite protection

Foundation anchorage (230318 230411) (230833 23086)

Structural composite lumber (230319) Floor joists (Tables 23088[1] 23088[2])

Structural log members (2303110) Wall studs (Table 230891) Round timber poles and piles Girders (Tables 230895 and 230896

(2303111) 23087)

Fire-retardant-treated wood (23032) Ceiling joists (Tables 2308102[1] 2308102[2])Hardwood and plywood (23033)

Roof rafters (Tables 2308103[1]shyTrusses (23034) 2308103[6])

Joist hangers and connectors (23035) Roof uplift (2308101)

10

NONSTRUCTURAL MATERIALS (Chapters 24 25 26) GLASS AND GLAZING (Chapter 24)

Sloped glazing and skylights (2405) Safety glazing (2406 2407 2408 2409)

GYPSUM BOARD AND PLASTER (Chapter 25)

Gypsum board materials Plaster (2507 2508 2510- 2513)(2506 Table 25062 Table 25081)

PLASTIC (Chapter 26)

FOAM PLASTIC INSULATION (2603) Protection against termites (26038)

Labeling (26032 260356) Special approval (26039)

Surface-burning characteristics MISCELLANEOUS PLASTICS(26033 260354)

Interior finish and trim (2604)Thermal barrier (26034) Plastic veneer (2605)Exterior wallsRoofs (26035 26036) Light-transmitting plastics (2606- 2611)

BUILDING SERVICES (Chapters 27 28 29 30) ELEVATORS AND CONVEYING SYSTEMS (Chapter 30)

Construction standard specified (30012) Hoistway venting (3004)

Hoistway enclosures (3002) Conveying systems (3005)

Opening protectives (300211) Machine rooms (3006)

Emergency operations (3003)

Also see Electrical (Ch27) Mechanical (Ch28) and Plumbing (Ch29) Plan Review Records

SPECIAL DEVICES AND CONDITIONS (Chapters 31 34) SPECIAL CONSTRUCTION Chapter 31)

Membrane structures (3102) PEDESTRIAN WALKWAYS AND TUNNELS (3104)

Awnings and canopiesMarquees Construction and use (31043 31044)(3105 3106)

Separation (31045 310410)Signs (3107)

Public way (31046)Radio and television towers (3108)

Egress (3104 7- 31049)Swimming pool enclosures (3109)

EXISTING STRUCTURES (Chapter 34)

Additions alterations repairs (3403) Accessibility (3409)

Fire escapes (3404) Compliance alternatives (3410)

Change of occupancy (3406)

11

----------------

BUILDING EVALUATION SUMMARY (Table 34107)

Existing occupancy _______________ Proposed occupancy Year building was constructed ____________ Number of stories ______ Height in feet Type of construction Area per floor Percentage of frontage Corridor wall rating _______________ Completely suppressed Yes ___ No Required door closers _____Yes ___No ___ Compartmentation Yes ___ No Fireresistance rating of vertical opening enclosures Type of HVAC system --------------- serving number of floors Automatic fire detection Yes No ___ type and location Fire alarm system Yes ___ No ___ type --------------------Smoke control Yes No ___ type -------------------Adequate exit routes Yes ___ No Dead ends Yes No ___ Maximum exit access travel distance __________ Elevator controls Yes No Means of egress emergency lighting Yes __ No ___ Mixed occupancies Yes No

Safety Fire Means General parameters safety (FS) of egress (ME) safety (GS)

341061 Building height

341062 Building area

341063 Compartmentation

341064 Tenant and dwelling unit separations

341065 Corridor walls

341066 Vertical openings

341067 HVAC systems

341068 Automatic fire detection

341069 Fire alarm system

3410610 Smoke control

3410611 Means of egress

341012 Dead ends

341013 Max exit access travel distance

3410614 Elevator control

3410615 Means of egress emergency lighting

3410616 Mixed occupancies

3410617 Automatic sprinklers 7 2 =

3410618 Incidental use

Building score -total value

No applicable value to be inserted

BUILDING SAFETY EVALUATION SCORE (Table 34109)

Formula Table 34107 Table 34108 Score Pass Fail

FS-MFS ~0 (FS) (MFS) = ME-MME 2 0 (ME) (MME) = GS-MGS gt 0 (GS) (MGS) =

FS = Fire Safety MFS = Mandatory Fire Safety ME = Means of Egress MME = Mandatory Means of Egress GS = General Safety MGS = Mandatory General Safety

APPENDICES A- J

Appendices adopted (10121) Compliance verified

12

Page 4: NOTES: N.R. N.A.- Not applicable ADMINISTRATION {Chapter 1) · Mixed Occupancy (508.3) Accessory occupancies (508.3.1) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to

EXTERIOR WALLS (continued)

D___

D__ D__

Opening protection (7048 70412 70414)

Vertical fire spread protection (7049 70410)

Parapets (704 11)

FIRE BARRIERS (706)

D___ D__

D__ D___ D__ D___ D__

Shaft enclosures (70631)

Exit enclosuresexit passageway (70632 70633)

Horizontal exits (70634)

Atriums (70635)

Incidental use areas (706 3 6)

Control areas (7063 7)

Mixed occupancy and fire area separations (70638 70639)

INTERIOR FINISHES (Chapter 8)

Smoke development (803 1) Floor finish (804)

Flame spread (803 1) Decorations and trim (806)

Non-textile finish (8032)

FIRE PROTECTION (Chapter 9) AUTOMATIC SPRINKLER SYSTEMS (903) (Where required)

Assembly (A-1 A-2 A-3 A-4 A-5) (90321)

Educational (E) (90322)

FactoryIndustrial (F-1) (90323) High-hazard (H-1 H-2 H-3 H-4 H-5)

(90324) Institutional (1-1 1-2 1-3 1-4)

(4075 90325)

Mercantile (M) (90326) Residential (R) (9032 7) StorageRepair garage (S-1) (90328) Pcrking garages (90329) Windowless story (9032101) Rubbish and linen chutes (9032102) Buildings over 55 ft high (9032103) Incidental uses (5082)

Additional required systems (Table 903213)

International Fire Code (FC 903213) AUTOMATIC SPRINKLER SYSTEMS (903) (Design)

Shop drawings (106111) NFPA 13 system (903311)

NFPA 13R system (903312) NFPA 13D system (903313) Quick-response and residential heads

(90332) Actuation (90334)

Water supplies (90335) Hose threads (90336) Sprinkler monitoring and alarms

(9034 90713)

Also see Fire Code Sprinkler Plan Review Record

4

SHAFTS (707)

D__ D__ OTHER FIRE-RESISTANT CONSTRUCTION

D___ D__ D__

Fire walls (705)

Fire partitions (708)

Smoke barriers (709)

Smoke partitions (710)

Penetrations (712)

Fire-resistant joint systems (713)

Opening protectives (715)

Dampers (716)

Concealed spaces (717)

Thermal- and sound-insulating materials (719)

Exceptions (7072)

Construction (7073- 70714)

ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS (904)

Installation (9043)

Wet-chemical systems (9045)

Dry-chemical systems (904 6)

Foam systems (904 7)

Carbon dioxide systems (9048)

Halon systems (9049)

Clean-agent systems (90410)

Commercial cooking systems (90421 90411)

STANDPIPE SYSTEMS (905)

Installation standards (9052)

Building height (90531)

Group A (90532)

Covered malls (90533)

Stages (90534)

Underground buildings (90535)

Helistopsheliports (9053 6)

Marinasboatyards (9053 7)

Hose connections and locations (9051 9054 9055 9056)

Cabinets (905 7)

Dry standpipes (9058)

Valve supervision (9059)

PORTABLE FIRE EXTINGUISHERS (906)

Required locations- IFC (9061)

FIRE ALARM AND DETECTION SYSTEMS (907)(Where required)

Construction documents (90711)

Assembly (A-1 A-2 A-3 A-4 A-5) (90721)

Business (B) (90722)

Educational (E) (90723)

Factory (F-1 F-2) (90724)

High-hazard (H-1 H-2 H-3 H-4 H-5) (90725)

Institutional (1-1 1-2 1-3 1-4) (90726)

Mercantile (M) (9072 7)

Residential (R-1 R-2) (90728 90729)

Singlemultiple station smoke alarms (907210)

High-rise buildings (907212)

Atriums (907213)

Other buildingsareas (907211 907214- 907223)

FIRE ALARM AND DETECTION SYSTEMS (907)(Design)

Residential smoke alarm power source (9072102)

Residential smoke alarm interconnection (9072103)

LocationPower supplyWiring (9073 - 9075)

ActivationPresignaiZones (9076- 9078)

Alarm notification appliances (9079)

Detectors (907 10 - 907 12)

Monitoring (907 14)

EMERGENCY ALARM SYSTEMS (908)

Detection system applicable (908 1 - 908 6)

SMOKE CONTROL SYSTEMS (909)

Where required (4029 4044 4055 4088 410372 102017 1025621)

Design requirements (909 1 - 9094)

Smoke barriers (9095)

Pressurization method (9096)

Airflow design method (909 7)

Exhaust method (9098)

Design fire (9099)

EquipmentPower (90910 90911)

Detection and control (909 12 - 909 18)

Smokeproof enclosures (90920)

SMOKE AND HEAT VENTS (910)

Requirements (9101- 9103)

Mechanical alternative (9104)

FIRE COMMAND CENTER (911)

Features (9111)

FIRE DEPARTMENT CONNECTIONS (912)

Installation (912 1 - 9125)

5

OCCUPANT NEEDS (Chapters 10 11 12)

MEANS OF EGRESS (Chapter 10)

OCCUPANT LOAD (100411 and Table 100411) CAPACITY OF EGRESS COMPONENTS (10051 and Table 10051)

Location Floor Area

Sqft person

= Occt load

Other acct loads

Total Egress width (inchoccupant)

Stairways ___

Other egress components ___

CAPACITY

Other egress Location Stairways components

NUMBER OF EXITS (10191 10192)

Location Required Shown

6

MEANS OF EGRESS (continued)

GENERAL MEANS OF EGRESS

Design requirements (10032- 10037)

Means of egress illumination (1006)

Exit signs (1011)

Accessible means of egress (1 007)

Means of egress doors (10081-100812)

Special doorsGatesTurnstiles (100813 10082 10083)

EXIT ACCESS

Door number and arrangement (10142 10151 10152)

Common path of egress travel (10143)

Exit access travel distance (10161)

EXITS I EXIT DISCHARGE

ExitsExit doors (1018 1019)

Vertical exit enclosures (1020)

Exit passageways (1021)

OTHER MEANS OF EGRESS

Miscellaneous egress requirements (10153- 10156)

Bleachers (102511)

Assembly exits amp egress (10252- 10255)

ACCESSIBILITY (Chapter 11)

Scoping requirements (1103)

Accessible route (1104)

Accessible entrances (1105)

Parking and passenger loading (1106)

Also see Accessibility Plan Review Record

Door landingsThresholdsArrangement (100814 -10081 7)

Door hardware (100818 100819)

Stairways (1009)

Roof access (100911)

Ramps (1010)

Handrails (1012)

Guards (1013)

Aisles (1 0144)

Egress balconies (10145 10163)

Corridors (1017)

Air movement in corridors (10174)

Horizontal exits (1022)

Exterior exit rampsstairways (1023)

Exit discharge (1024)

Assembly aisles amp features (10256- 102515)

Emergency escape and rescue (1026)

Dwelling units and sleeping units (1107)

Special occupancies (1108)

Features and facilities (1109)

Signage (1110)

7

INTERIOR ENVIRONMENT (Chapter 12)

Ventilation openings (1203) Sound transmission (1207)

Temperature control (1204) Interior space dimensions (1208)

Lighting (1205) Access to unoccupied spaces (1209)

Yards or courts (1206) Surrounding materials (1210 2509)

Also see Mechanical Code Plan Review Record

BUILDING ENVELOPE Chapters 13 14 15) See Energy Conservation Code Plan Review Record

EXTERIOR WALLS (Chapter 14)

Performance requirements (1403) Exterior wall coveringsMCMs (1405 1407)

Materials (1404) Combustible material restrictions (1406)

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (Chapter 15)

Weather protection (1503) Materials (1506)

Flashing (15032 150729 150739 Roof coverings (1507) 150756 150776 150787 150798) Roof insulation (1508)

Performance requirements (1504) Rooftop structures (1509)

Fire classification (1505) Reroofing (1510)

STRUCTURAL SYSTEMS Chapters 16 17 18) STRUCTURAL DESIGN (Chapter 16)

STRUCTURAL DESIGN CALCULATIONS Live load reduction (160311 16079 160710)

Submitted for all structural members Roof live loads (160312 160711)(1061 10611)

Roof snow loads (160313 1608 Chapter 7 ofASCE 7) DESIGN LOADS ON CONSTRUCTION DOCUMENTS Ground snow load pg (16082 72 of(1603) ASCE 7)

If pg gt 10 psf flat-roof snow load pr(73 ofUniformly distributed floor live loads (160311 ASCE 7)Table 1607 1)

If pg gt 1 0 psf snow exposure factor Ce Floor Area Use Loads Shown (Table 7-2 731 of ASCE 7)

If pg gt 10 psf snow load importance factor I (733 Table 7-4 ofASCE 7)

Roof thermal factor Ct (Table 7-3 732 of ASCE 7)

Sloped roof snow load Ps (74 ofASCE 7)

8

DESIGN LOADS (continued)

Wind loads (160314 1609 Chapter 6 of ASCE 7)

Design procedure (612 ofASCE 7)

Basic wind speed (16093 Fig 6-1 of ASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Wind importance factor I (Table 6-1 655 ofASCE 7)

Surface roughnessExposure categories (16094 656 ofASCE 7)

Internal pressure coefficient (Fig 6-5 65111 of ASCE 7)

Component and cladding pressures (6142 6422 65124 ofASCE 7)

Main wind-force resisting system (6141 6421 65122 ofASCE 7)

Earthquake design data (160315 1613 Chapter 11- 13 and 15-23 ofASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Seismic importance factor (1151 Table 115-1 ofASCE 7)

Mapped spectral response acceleration Ss and St (161351 1141 of ASCE 7)

Spectral response coefficients Sos amp Sot (161354 1144 ofASCE 7)

Site class (161352 1142 ofASCE 7)

Seismic design category (161356 116 of ASCE 7)

Basic seismic-force-resisting system (Table 122-1 of ASCE 7)

Response modification coefficient R and deflection amplification factor Cd (Table 122-1 ofASCE 7)

Analysis procedure (126 of ASCE 7)

Design base shear (128 of ASCE 7)

Flood loads (160316 1612)

Flood hazard area (16123)

Elevation of structure (16125)

Other loads

Concentrated loads (16074)

Partition loads (16075)

Impact loads (16078)

Misc loads (Table 16076 160761 16077 160712 160713 1610 1611 2404)

QUALITY ASSURANCE (Chapter 17)

ApprovalsResearch report(s )(1703 170342) Report No____

Statement of special inspections (170411 1705)

Prefabricated items (17042)

Steel construction (17043)

Concrete construction (17044)

Masonry construction (17045)

Wood construction (17046)

Prepared fill and foundations

(1704 7 17048 17049)

Sprayed fire-resistant materials and coatings (170410 170411)

EIFS (170412)

Smoke control (170414)

Seismic resistance (1707)

Structural testingObservations (seismic) (1708 1709)

Testing (other) (1710- 1715)

SOILS AND FOUNDATIONS (Chapter 18)

Soils investigationsReports (18021 18022 18026)

Soil classification (18023)

Excavation grading and fill (1803)

Load-bearing values (1804)

Footings and foundations (1805)

Retaining walls (1806)

Dampproofing and waterproofing (1807)

Foundations (other types) (1808 - 1812)

9

STRUCTURAL MATERIALS (Chapters 19 21 22 23) CONCRETE (Chapter 19)

Plain and reinforced concrete Minimum concrete strength designconstruction standard (Table 190422) specified (19012 1908) Cold weather and hot weather construc-

Construction documents (19014) tion specified (190512 190513)

Slab provisions (1910)

MASONRY (Chapter 21) Design method construction standard Cold weather and hot weather construc-

specified (21012) tion specified (21043 21044)

Construction documents (21013) Seismic design (2106)

Construction materials (2103) Glass unit masonry (2110)

Mortar type (21038) FireplacesHeatersChimneys (2111 2112 2113)

STEEL (Chapter 22) Structural steel designconstruction Steel storage racks (2208)

standard specified (2205) Cold-formed steel designconstruction

Open-web steel joist designconstruction standard specified (2209) standard specified (2206)

Cold-formed steel light-framed design Steel cable structures (2207) construction standard specified (2210)

WOOD (Chapter 23) Design method option used (23012) Fasteners and fastening

(23036 23049 Table 230491)MATERIAL STANDARDS I CONSTRUCTION REQUIREMENTS (2303- 2306) Heavy timber construction (230410)

Lumber (230311) Shear walls and diaphragms (2305 2306) Wood -joists (230312)

CONVENTIONAL LIGHT-FRAME CONSTRUCTION Glue-laminated timbers (230313) (2308) Wood structural panels Limitations satisfied (23082)

(230314 23046 2304 7) WindSeismic requirements (230821

Fiber- hard- ampparticle- boards 230822 230811 230812) (2303 1 5 - 2303 1 7)

Braced walls (23083 230893) Decay and termite protection

Foundation anchorage (230318 230411) (230833 23086)

Structural composite lumber (230319) Floor joists (Tables 23088[1] 23088[2])

Structural log members (2303110) Wall studs (Table 230891) Round timber poles and piles Girders (Tables 230895 and 230896

(2303111) 23087)

Fire-retardant-treated wood (23032) Ceiling joists (Tables 2308102[1] 2308102[2])Hardwood and plywood (23033)

Roof rafters (Tables 2308103[1]shyTrusses (23034) 2308103[6])

Joist hangers and connectors (23035) Roof uplift (2308101)

10

NONSTRUCTURAL MATERIALS (Chapters 24 25 26) GLASS AND GLAZING (Chapter 24)

Sloped glazing and skylights (2405) Safety glazing (2406 2407 2408 2409)

GYPSUM BOARD AND PLASTER (Chapter 25)

Gypsum board materials Plaster (2507 2508 2510- 2513)(2506 Table 25062 Table 25081)

PLASTIC (Chapter 26)

FOAM PLASTIC INSULATION (2603) Protection against termites (26038)

Labeling (26032 260356) Special approval (26039)

Surface-burning characteristics MISCELLANEOUS PLASTICS(26033 260354)

Interior finish and trim (2604)Thermal barrier (26034) Plastic veneer (2605)Exterior wallsRoofs (26035 26036) Light-transmitting plastics (2606- 2611)

BUILDING SERVICES (Chapters 27 28 29 30) ELEVATORS AND CONVEYING SYSTEMS (Chapter 30)

Construction standard specified (30012) Hoistway venting (3004)

Hoistway enclosures (3002) Conveying systems (3005)

Opening protectives (300211) Machine rooms (3006)

Emergency operations (3003)

Also see Electrical (Ch27) Mechanical (Ch28) and Plumbing (Ch29) Plan Review Records

SPECIAL DEVICES AND CONDITIONS (Chapters 31 34) SPECIAL CONSTRUCTION Chapter 31)

Membrane structures (3102) PEDESTRIAN WALKWAYS AND TUNNELS (3104)

Awnings and canopiesMarquees Construction and use (31043 31044)(3105 3106)

Separation (31045 310410)Signs (3107)

Public way (31046)Radio and television towers (3108)

Egress (3104 7- 31049)Swimming pool enclosures (3109)

EXISTING STRUCTURES (Chapter 34)

Additions alterations repairs (3403) Accessibility (3409)

Fire escapes (3404) Compliance alternatives (3410)

Change of occupancy (3406)

11

----------------

BUILDING EVALUATION SUMMARY (Table 34107)

Existing occupancy _______________ Proposed occupancy Year building was constructed ____________ Number of stories ______ Height in feet Type of construction Area per floor Percentage of frontage Corridor wall rating _______________ Completely suppressed Yes ___ No Required door closers _____Yes ___No ___ Compartmentation Yes ___ No Fireresistance rating of vertical opening enclosures Type of HVAC system --------------- serving number of floors Automatic fire detection Yes No ___ type and location Fire alarm system Yes ___ No ___ type --------------------Smoke control Yes No ___ type -------------------Adequate exit routes Yes ___ No Dead ends Yes No ___ Maximum exit access travel distance __________ Elevator controls Yes No Means of egress emergency lighting Yes __ No ___ Mixed occupancies Yes No

Safety Fire Means General parameters safety (FS) of egress (ME) safety (GS)

341061 Building height

341062 Building area

341063 Compartmentation

341064 Tenant and dwelling unit separations

341065 Corridor walls

341066 Vertical openings

341067 HVAC systems

341068 Automatic fire detection

341069 Fire alarm system

3410610 Smoke control

3410611 Means of egress

341012 Dead ends

341013 Max exit access travel distance

3410614 Elevator control

3410615 Means of egress emergency lighting

3410616 Mixed occupancies

3410617 Automatic sprinklers 7 2 =

3410618 Incidental use

Building score -total value

No applicable value to be inserted

BUILDING SAFETY EVALUATION SCORE (Table 34109)

Formula Table 34107 Table 34108 Score Pass Fail

FS-MFS ~0 (FS) (MFS) = ME-MME 2 0 (ME) (MME) = GS-MGS gt 0 (GS) (MGS) =

FS = Fire Safety MFS = Mandatory Fire Safety ME = Means of Egress MME = Mandatory Means of Egress GS = General Safety MGS = Mandatory General Safety

APPENDICES A- J

Appendices adopted (10121) Compliance verified

12

Page 5: NOTES: N.R. N.A.- Not applicable ADMINISTRATION {Chapter 1) · Mixed Occupancy (508.3) Accessory occupancies (508.3.1) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to

ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS (904)

Installation (9043)

Wet-chemical systems (9045)

Dry-chemical systems (904 6)

Foam systems (904 7)

Carbon dioxide systems (9048)

Halon systems (9049)

Clean-agent systems (90410)

Commercial cooking systems (90421 90411)

STANDPIPE SYSTEMS (905)

Installation standards (9052)

Building height (90531)

Group A (90532)

Covered malls (90533)

Stages (90534)

Underground buildings (90535)

Helistopsheliports (9053 6)

Marinasboatyards (9053 7)

Hose connections and locations (9051 9054 9055 9056)

Cabinets (905 7)

Dry standpipes (9058)

Valve supervision (9059)

PORTABLE FIRE EXTINGUISHERS (906)

Required locations- IFC (9061)

FIRE ALARM AND DETECTION SYSTEMS (907)(Where required)

Construction documents (90711)

Assembly (A-1 A-2 A-3 A-4 A-5) (90721)

Business (B) (90722)

Educational (E) (90723)

Factory (F-1 F-2) (90724)

High-hazard (H-1 H-2 H-3 H-4 H-5) (90725)

Institutional (1-1 1-2 1-3 1-4) (90726)

Mercantile (M) (9072 7)

Residential (R-1 R-2) (90728 90729)

Singlemultiple station smoke alarms (907210)

High-rise buildings (907212)

Atriums (907213)

Other buildingsareas (907211 907214- 907223)

FIRE ALARM AND DETECTION SYSTEMS (907)(Design)

Residential smoke alarm power source (9072102)

Residential smoke alarm interconnection (9072103)

LocationPower supplyWiring (9073 - 9075)

ActivationPresignaiZones (9076- 9078)

Alarm notification appliances (9079)

Detectors (907 10 - 907 12)

Monitoring (907 14)

EMERGENCY ALARM SYSTEMS (908)

Detection system applicable (908 1 - 908 6)

SMOKE CONTROL SYSTEMS (909)

Where required (4029 4044 4055 4088 410372 102017 1025621)

Design requirements (909 1 - 9094)

Smoke barriers (9095)

Pressurization method (9096)

Airflow design method (909 7)

Exhaust method (9098)

Design fire (9099)

EquipmentPower (90910 90911)

Detection and control (909 12 - 909 18)

Smokeproof enclosures (90920)

SMOKE AND HEAT VENTS (910)

Requirements (9101- 9103)

Mechanical alternative (9104)

FIRE COMMAND CENTER (911)

Features (9111)

FIRE DEPARTMENT CONNECTIONS (912)

Installation (912 1 - 9125)

5

OCCUPANT NEEDS (Chapters 10 11 12)

MEANS OF EGRESS (Chapter 10)

OCCUPANT LOAD (100411 and Table 100411) CAPACITY OF EGRESS COMPONENTS (10051 and Table 10051)

Location Floor Area

Sqft person

= Occt load

Other acct loads

Total Egress width (inchoccupant)

Stairways ___

Other egress components ___

CAPACITY

Other egress Location Stairways components

NUMBER OF EXITS (10191 10192)

Location Required Shown

6

MEANS OF EGRESS (continued)

GENERAL MEANS OF EGRESS

Design requirements (10032- 10037)

Means of egress illumination (1006)

Exit signs (1011)

Accessible means of egress (1 007)

Means of egress doors (10081-100812)

Special doorsGatesTurnstiles (100813 10082 10083)

EXIT ACCESS

Door number and arrangement (10142 10151 10152)

Common path of egress travel (10143)

Exit access travel distance (10161)

EXITS I EXIT DISCHARGE

ExitsExit doors (1018 1019)

Vertical exit enclosures (1020)

Exit passageways (1021)

OTHER MEANS OF EGRESS

Miscellaneous egress requirements (10153- 10156)

Bleachers (102511)

Assembly exits amp egress (10252- 10255)

ACCESSIBILITY (Chapter 11)

Scoping requirements (1103)

Accessible route (1104)

Accessible entrances (1105)

Parking and passenger loading (1106)

Also see Accessibility Plan Review Record

Door landingsThresholdsArrangement (100814 -10081 7)

Door hardware (100818 100819)

Stairways (1009)

Roof access (100911)

Ramps (1010)

Handrails (1012)

Guards (1013)

Aisles (1 0144)

Egress balconies (10145 10163)

Corridors (1017)

Air movement in corridors (10174)

Horizontal exits (1022)

Exterior exit rampsstairways (1023)

Exit discharge (1024)

Assembly aisles amp features (10256- 102515)

Emergency escape and rescue (1026)

Dwelling units and sleeping units (1107)

Special occupancies (1108)

Features and facilities (1109)

Signage (1110)

7

INTERIOR ENVIRONMENT (Chapter 12)

Ventilation openings (1203) Sound transmission (1207)

Temperature control (1204) Interior space dimensions (1208)

Lighting (1205) Access to unoccupied spaces (1209)

Yards or courts (1206) Surrounding materials (1210 2509)

Also see Mechanical Code Plan Review Record

BUILDING ENVELOPE Chapters 13 14 15) See Energy Conservation Code Plan Review Record

EXTERIOR WALLS (Chapter 14)

Performance requirements (1403) Exterior wall coveringsMCMs (1405 1407)

Materials (1404) Combustible material restrictions (1406)

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (Chapter 15)

Weather protection (1503) Materials (1506)

Flashing (15032 150729 150739 Roof coverings (1507) 150756 150776 150787 150798) Roof insulation (1508)

Performance requirements (1504) Rooftop structures (1509)

Fire classification (1505) Reroofing (1510)

STRUCTURAL SYSTEMS Chapters 16 17 18) STRUCTURAL DESIGN (Chapter 16)

STRUCTURAL DESIGN CALCULATIONS Live load reduction (160311 16079 160710)

Submitted for all structural members Roof live loads (160312 160711)(1061 10611)

Roof snow loads (160313 1608 Chapter 7 ofASCE 7) DESIGN LOADS ON CONSTRUCTION DOCUMENTS Ground snow load pg (16082 72 of(1603) ASCE 7)

If pg gt 10 psf flat-roof snow load pr(73 ofUniformly distributed floor live loads (160311 ASCE 7)Table 1607 1)

If pg gt 1 0 psf snow exposure factor Ce Floor Area Use Loads Shown (Table 7-2 731 of ASCE 7)

If pg gt 10 psf snow load importance factor I (733 Table 7-4 ofASCE 7)

Roof thermal factor Ct (Table 7-3 732 of ASCE 7)

Sloped roof snow load Ps (74 ofASCE 7)

8

DESIGN LOADS (continued)

Wind loads (160314 1609 Chapter 6 of ASCE 7)

Design procedure (612 ofASCE 7)

Basic wind speed (16093 Fig 6-1 of ASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Wind importance factor I (Table 6-1 655 ofASCE 7)

Surface roughnessExposure categories (16094 656 ofASCE 7)

Internal pressure coefficient (Fig 6-5 65111 of ASCE 7)

Component and cladding pressures (6142 6422 65124 ofASCE 7)

Main wind-force resisting system (6141 6421 65122 ofASCE 7)

Earthquake design data (160315 1613 Chapter 11- 13 and 15-23 ofASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Seismic importance factor (1151 Table 115-1 ofASCE 7)

Mapped spectral response acceleration Ss and St (161351 1141 of ASCE 7)

Spectral response coefficients Sos amp Sot (161354 1144 ofASCE 7)

Site class (161352 1142 ofASCE 7)

Seismic design category (161356 116 of ASCE 7)

Basic seismic-force-resisting system (Table 122-1 of ASCE 7)

Response modification coefficient R and deflection amplification factor Cd (Table 122-1 ofASCE 7)

Analysis procedure (126 of ASCE 7)

Design base shear (128 of ASCE 7)

Flood loads (160316 1612)

Flood hazard area (16123)

Elevation of structure (16125)

Other loads

Concentrated loads (16074)

Partition loads (16075)

Impact loads (16078)

Misc loads (Table 16076 160761 16077 160712 160713 1610 1611 2404)

QUALITY ASSURANCE (Chapter 17)

ApprovalsResearch report(s )(1703 170342) Report No____

Statement of special inspections (170411 1705)

Prefabricated items (17042)

Steel construction (17043)

Concrete construction (17044)

Masonry construction (17045)

Wood construction (17046)

Prepared fill and foundations

(1704 7 17048 17049)

Sprayed fire-resistant materials and coatings (170410 170411)

EIFS (170412)

Smoke control (170414)

Seismic resistance (1707)

Structural testingObservations (seismic) (1708 1709)

Testing (other) (1710- 1715)

SOILS AND FOUNDATIONS (Chapter 18)

Soils investigationsReports (18021 18022 18026)

Soil classification (18023)

Excavation grading and fill (1803)

Load-bearing values (1804)

Footings and foundations (1805)

Retaining walls (1806)

Dampproofing and waterproofing (1807)

Foundations (other types) (1808 - 1812)

9

STRUCTURAL MATERIALS (Chapters 19 21 22 23) CONCRETE (Chapter 19)

Plain and reinforced concrete Minimum concrete strength designconstruction standard (Table 190422) specified (19012 1908) Cold weather and hot weather construc-

Construction documents (19014) tion specified (190512 190513)

Slab provisions (1910)

MASONRY (Chapter 21) Design method construction standard Cold weather and hot weather construc-

specified (21012) tion specified (21043 21044)

Construction documents (21013) Seismic design (2106)

Construction materials (2103) Glass unit masonry (2110)

Mortar type (21038) FireplacesHeatersChimneys (2111 2112 2113)

STEEL (Chapter 22) Structural steel designconstruction Steel storage racks (2208)

standard specified (2205) Cold-formed steel designconstruction

Open-web steel joist designconstruction standard specified (2209) standard specified (2206)

Cold-formed steel light-framed design Steel cable structures (2207) construction standard specified (2210)

WOOD (Chapter 23) Design method option used (23012) Fasteners and fastening

(23036 23049 Table 230491)MATERIAL STANDARDS I CONSTRUCTION REQUIREMENTS (2303- 2306) Heavy timber construction (230410)

Lumber (230311) Shear walls and diaphragms (2305 2306) Wood -joists (230312)

CONVENTIONAL LIGHT-FRAME CONSTRUCTION Glue-laminated timbers (230313) (2308) Wood structural panels Limitations satisfied (23082)

(230314 23046 2304 7) WindSeismic requirements (230821

Fiber- hard- ampparticle- boards 230822 230811 230812) (2303 1 5 - 2303 1 7)

Braced walls (23083 230893) Decay and termite protection

Foundation anchorage (230318 230411) (230833 23086)

Structural composite lumber (230319) Floor joists (Tables 23088[1] 23088[2])

Structural log members (2303110) Wall studs (Table 230891) Round timber poles and piles Girders (Tables 230895 and 230896

(2303111) 23087)

Fire-retardant-treated wood (23032) Ceiling joists (Tables 2308102[1] 2308102[2])Hardwood and plywood (23033)

Roof rafters (Tables 2308103[1]shyTrusses (23034) 2308103[6])

Joist hangers and connectors (23035) Roof uplift (2308101)

10

NONSTRUCTURAL MATERIALS (Chapters 24 25 26) GLASS AND GLAZING (Chapter 24)

Sloped glazing and skylights (2405) Safety glazing (2406 2407 2408 2409)

GYPSUM BOARD AND PLASTER (Chapter 25)

Gypsum board materials Plaster (2507 2508 2510- 2513)(2506 Table 25062 Table 25081)

PLASTIC (Chapter 26)

FOAM PLASTIC INSULATION (2603) Protection against termites (26038)

Labeling (26032 260356) Special approval (26039)

Surface-burning characteristics MISCELLANEOUS PLASTICS(26033 260354)

Interior finish and trim (2604)Thermal barrier (26034) Plastic veneer (2605)Exterior wallsRoofs (26035 26036) Light-transmitting plastics (2606- 2611)

BUILDING SERVICES (Chapters 27 28 29 30) ELEVATORS AND CONVEYING SYSTEMS (Chapter 30)

Construction standard specified (30012) Hoistway venting (3004)

Hoistway enclosures (3002) Conveying systems (3005)

Opening protectives (300211) Machine rooms (3006)

Emergency operations (3003)

Also see Electrical (Ch27) Mechanical (Ch28) and Plumbing (Ch29) Plan Review Records

SPECIAL DEVICES AND CONDITIONS (Chapters 31 34) SPECIAL CONSTRUCTION Chapter 31)

Membrane structures (3102) PEDESTRIAN WALKWAYS AND TUNNELS (3104)

Awnings and canopiesMarquees Construction and use (31043 31044)(3105 3106)

Separation (31045 310410)Signs (3107)

Public way (31046)Radio and television towers (3108)

Egress (3104 7- 31049)Swimming pool enclosures (3109)

EXISTING STRUCTURES (Chapter 34)

Additions alterations repairs (3403) Accessibility (3409)

Fire escapes (3404) Compliance alternatives (3410)

Change of occupancy (3406)

11

----------------

BUILDING EVALUATION SUMMARY (Table 34107)

Existing occupancy _______________ Proposed occupancy Year building was constructed ____________ Number of stories ______ Height in feet Type of construction Area per floor Percentage of frontage Corridor wall rating _______________ Completely suppressed Yes ___ No Required door closers _____Yes ___No ___ Compartmentation Yes ___ No Fireresistance rating of vertical opening enclosures Type of HVAC system --------------- serving number of floors Automatic fire detection Yes No ___ type and location Fire alarm system Yes ___ No ___ type --------------------Smoke control Yes No ___ type -------------------Adequate exit routes Yes ___ No Dead ends Yes No ___ Maximum exit access travel distance __________ Elevator controls Yes No Means of egress emergency lighting Yes __ No ___ Mixed occupancies Yes No

Safety Fire Means General parameters safety (FS) of egress (ME) safety (GS)

341061 Building height

341062 Building area

341063 Compartmentation

341064 Tenant and dwelling unit separations

341065 Corridor walls

341066 Vertical openings

341067 HVAC systems

341068 Automatic fire detection

341069 Fire alarm system

3410610 Smoke control

3410611 Means of egress

341012 Dead ends

341013 Max exit access travel distance

3410614 Elevator control

3410615 Means of egress emergency lighting

3410616 Mixed occupancies

3410617 Automatic sprinklers 7 2 =

3410618 Incidental use

Building score -total value

No applicable value to be inserted

BUILDING SAFETY EVALUATION SCORE (Table 34109)

Formula Table 34107 Table 34108 Score Pass Fail

FS-MFS ~0 (FS) (MFS) = ME-MME 2 0 (ME) (MME) = GS-MGS gt 0 (GS) (MGS) =

FS = Fire Safety MFS = Mandatory Fire Safety ME = Means of Egress MME = Mandatory Means of Egress GS = General Safety MGS = Mandatory General Safety

APPENDICES A- J

Appendices adopted (10121) Compliance verified

12

Page 6: NOTES: N.R. N.A.- Not applicable ADMINISTRATION {Chapter 1) · Mixed Occupancy (508.3) Accessory occupancies (508.3.1) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to

OCCUPANT NEEDS (Chapters 10 11 12)

MEANS OF EGRESS (Chapter 10)

OCCUPANT LOAD (100411 and Table 100411) CAPACITY OF EGRESS COMPONENTS (10051 and Table 10051)

Location Floor Area

Sqft person

= Occt load

Other acct loads

Total Egress width (inchoccupant)

Stairways ___

Other egress components ___

CAPACITY

Other egress Location Stairways components

NUMBER OF EXITS (10191 10192)

Location Required Shown

6

MEANS OF EGRESS (continued)

GENERAL MEANS OF EGRESS

Design requirements (10032- 10037)

Means of egress illumination (1006)

Exit signs (1011)

Accessible means of egress (1 007)

Means of egress doors (10081-100812)

Special doorsGatesTurnstiles (100813 10082 10083)

EXIT ACCESS

Door number and arrangement (10142 10151 10152)

Common path of egress travel (10143)

Exit access travel distance (10161)

EXITS I EXIT DISCHARGE

ExitsExit doors (1018 1019)

Vertical exit enclosures (1020)

Exit passageways (1021)

OTHER MEANS OF EGRESS

Miscellaneous egress requirements (10153- 10156)

Bleachers (102511)

Assembly exits amp egress (10252- 10255)

ACCESSIBILITY (Chapter 11)

Scoping requirements (1103)

Accessible route (1104)

Accessible entrances (1105)

Parking and passenger loading (1106)

Also see Accessibility Plan Review Record

Door landingsThresholdsArrangement (100814 -10081 7)

Door hardware (100818 100819)

Stairways (1009)

Roof access (100911)

Ramps (1010)

Handrails (1012)

Guards (1013)

Aisles (1 0144)

Egress balconies (10145 10163)

Corridors (1017)

Air movement in corridors (10174)

Horizontal exits (1022)

Exterior exit rampsstairways (1023)

Exit discharge (1024)

Assembly aisles amp features (10256- 102515)

Emergency escape and rescue (1026)

Dwelling units and sleeping units (1107)

Special occupancies (1108)

Features and facilities (1109)

Signage (1110)

7

INTERIOR ENVIRONMENT (Chapter 12)

Ventilation openings (1203) Sound transmission (1207)

Temperature control (1204) Interior space dimensions (1208)

Lighting (1205) Access to unoccupied spaces (1209)

Yards or courts (1206) Surrounding materials (1210 2509)

Also see Mechanical Code Plan Review Record

BUILDING ENVELOPE Chapters 13 14 15) See Energy Conservation Code Plan Review Record

EXTERIOR WALLS (Chapter 14)

Performance requirements (1403) Exterior wall coveringsMCMs (1405 1407)

Materials (1404) Combustible material restrictions (1406)

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (Chapter 15)

Weather protection (1503) Materials (1506)

Flashing (15032 150729 150739 Roof coverings (1507) 150756 150776 150787 150798) Roof insulation (1508)

Performance requirements (1504) Rooftop structures (1509)

Fire classification (1505) Reroofing (1510)

STRUCTURAL SYSTEMS Chapters 16 17 18) STRUCTURAL DESIGN (Chapter 16)

STRUCTURAL DESIGN CALCULATIONS Live load reduction (160311 16079 160710)

Submitted for all structural members Roof live loads (160312 160711)(1061 10611)

Roof snow loads (160313 1608 Chapter 7 ofASCE 7) DESIGN LOADS ON CONSTRUCTION DOCUMENTS Ground snow load pg (16082 72 of(1603) ASCE 7)

If pg gt 10 psf flat-roof snow load pr(73 ofUniformly distributed floor live loads (160311 ASCE 7)Table 1607 1)

If pg gt 1 0 psf snow exposure factor Ce Floor Area Use Loads Shown (Table 7-2 731 of ASCE 7)

If pg gt 10 psf snow load importance factor I (733 Table 7-4 ofASCE 7)

Roof thermal factor Ct (Table 7-3 732 of ASCE 7)

Sloped roof snow load Ps (74 ofASCE 7)

8

DESIGN LOADS (continued)

Wind loads (160314 1609 Chapter 6 of ASCE 7)

Design procedure (612 ofASCE 7)

Basic wind speed (16093 Fig 6-1 of ASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Wind importance factor I (Table 6-1 655 ofASCE 7)

Surface roughnessExposure categories (16094 656 ofASCE 7)

Internal pressure coefficient (Fig 6-5 65111 of ASCE 7)

Component and cladding pressures (6142 6422 65124 ofASCE 7)

Main wind-force resisting system (6141 6421 65122 ofASCE 7)

Earthquake design data (160315 1613 Chapter 11- 13 and 15-23 ofASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Seismic importance factor (1151 Table 115-1 ofASCE 7)

Mapped spectral response acceleration Ss and St (161351 1141 of ASCE 7)

Spectral response coefficients Sos amp Sot (161354 1144 ofASCE 7)

Site class (161352 1142 ofASCE 7)

Seismic design category (161356 116 of ASCE 7)

Basic seismic-force-resisting system (Table 122-1 of ASCE 7)

Response modification coefficient R and deflection amplification factor Cd (Table 122-1 ofASCE 7)

Analysis procedure (126 of ASCE 7)

Design base shear (128 of ASCE 7)

Flood loads (160316 1612)

Flood hazard area (16123)

Elevation of structure (16125)

Other loads

Concentrated loads (16074)

Partition loads (16075)

Impact loads (16078)

Misc loads (Table 16076 160761 16077 160712 160713 1610 1611 2404)

QUALITY ASSURANCE (Chapter 17)

ApprovalsResearch report(s )(1703 170342) Report No____

Statement of special inspections (170411 1705)

Prefabricated items (17042)

Steel construction (17043)

Concrete construction (17044)

Masonry construction (17045)

Wood construction (17046)

Prepared fill and foundations

(1704 7 17048 17049)

Sprayed fire-resistant materials and coatings (170410 170411)

EIFS (170412)

Smoke control (170414)

Seismic resistance (1707)

Structural testingObservations (seismic) (1708 1709)

Testing (other) (1710- 1715)

SOILS AND FOUNDATIONS (Chapter 18)

Soils investigationsReports (18021 18022 18026)

Soil classification (18023)

Excavation grading and fill (1803)

Load-bearing values (1804)

Footings and foundations (1805)

Retaining walls (1806)

Dampproofing and waterproofing (1807)

Foundations (other types) (1808 - 1812)

9

STRUCTURAL MATERIALS (Chapters 19 21 22 23) CONCRETE (Chapter 19)

Plain and reinforced concrete Minimum concrete strength designconstruction standard (Table 190422) specified (19012 1908) Cold weather and hot weather construc-

Construction documents (19014) tion specified (190512 190513)

Slab provisions (1910)

MASONRY (Chapter 21) Design method construction standard Cold weather and hot weather construc-

specified (21012) tion specified (21043 21044)

Construction documents (21013) Seismic design (2106)

Construction materials (2103) Glass unit masonry (2110)

Mortar type (21038) FireplacesHeatersChimneys (2111 2112 2113)

STEEL (Chapter 22) Structural steel designconstruction Steel storage racks (2208)

standard specified (2205) Cold-formed steel designconstruction

Open-web steel joist designconstruction standard specified (2209) standard specified (2206)

Cold-formed steel light-framed design Steel cable structures (2207) construction standard specified (2210)

WOOD (Chapter 23) Design method option used (23012) Fasteners and fastening

(23036 23049 Table 230491)MATERIAL STANDARDS I CONSTRUCTION REQUIREMENTS (2303- 2306) Heavy timber construction (230410)

Lumber (230311) Shear walls and diaphragms (2305 2306) Wood -joists (230312)

CONVENTIONAL LIGHT-FRAME CONSTRUCTION Glue-laminated timbers (230313) (2308) Wood structural panels Limitations satisfied (23082)

(230314 23046 2304 7) WindSeismic requirements (230821

Fiber- hard- ampparticle- boards 230822 230811 230812) (2303 1 5 - 2303 1 7)

Braced walls (23083 230893) Decay and termite protection

Foundation anchorage (230318 230411) (230833 23086)

Structural composite lumber (230319) Floor joists (Tables 23088[1] 23088[2])

Structural log members (2303110) Wall studs (Table 230891) Round timber poles and piles Girders (Tables 230895 and 230896

(2303111) 23087)

Fire-retardant-treated wood (23032) Ceiling joists (Tables 2308102[1] 2308102[2])Hardwood and plywood (23033)

Roof rafters (Tables 2308103[1]shyTrusses (23034) 2308103[6])

Joist hangers and connectors (23035) Roof uplift (2308101)

10

NONSTRUCTURAL MATERIALS (Chapters 24 25 26) GLASS AND GLAZING (Chapter 24)

Sloped glazing and skylights (2405) Safety glazing (2406 2407 2408 2409)

GYPSUM BOARD AND PLASTER (Chapter 25)

Gypsum board materials Plaster (2507 2508 2510- 2513)(2506 Table 25062 Table 25081)

PLASTIC (Chapter 26)

FOAM PLASTIC INSULATION (2603) Protection against termites (26038)

Labeling (26032 260356) Special approval (26039)

Surface-burning characteristics MISCELLANEOUS PLASTICS(26033 260354)

Interior finish and trim (2604)Thermal barrier (26034) Plastic veneer (2605)Exterior wallsRoofs (26035 26036) Light-transmitting plastics (2606- 2611)

BUILDING SERVICES (Chapters 27 28 29 30) ELEVATORS AND CONVEYING SYSTEMS (Chapter 30)

Construction standard specified (30012) Hoistway venting (3004)

Hoistway enclosures (3002) Conveying systems (3005)

Opening protectives (300211) Machine rooms (3006)

Emergency operations (3003)

Also see Electrical (Ch27) Mechanical (Ch28) and Plumbing (Ch29) Plan Review Records

SPECIAL DEVICES AND CONDITIONS (Chapters 31 34) SPECIAL CONSTRUCTION Chapter 31)

Membrane structures (3102) PEDESTRIAN WALKWAYS AND TUNNELS (3104)

Awnings and canopiesMarquees Construction and use (31043 31044)(3105 3106)

Separation (31045 310410)Signs (3107)

Public way (31046)Radio and television towers (3108)

Egress (3104 7- 31049)Swimming pool enclosures (3109)

EXISTING STRUCTURES (Chapter 34)

Additions alterations repairs (3403) Accessibility (3409)

Fire escapes (3404) Compliance alternatives (3410)

Change of occupancy (3406)

11

----------------

BUILDING EVALUATION SUMMARY (Table 34107)

Existing occupancy _______________ Proposed occupancy Year building was constructed ____________ Number of stories ______ Height in feet Type of construction Area per floor Percentage of frontage Corridor wall rating _______________ Completely suppressed Yes ___ No Required door closers _____Yes ___No ___ Compartmentation Yes ___ No Fireresistance rating of vertical opening enclosures Type of HVAC system --------------- serving number of floors Automatic fire detection Yes No ___ type and location Fire alarm system Yes ___ No ___ type --------------------Smoke control Yes No ___ type -------------------Adequate exit routes Yes ___ No Dead ends Yes No ___ Maximum exit access travel distance __________ Elevator controls Yes No Means of egress emergency lighting Yes __ No ___ Mixed occupancies Yes No

Safety Fire Means General parameters safety (FS) of egress (ME) safety (GS)

341061 Building height

341062 Building area

341063 Compartmentation

341064 Tenant and dwelling unit separations

341065 Corridor walls

341066 Vertical openings

341067 HVAC systems

341068 Automatic fire detection

341069 Fire alarm system

3410610 Smoke control

3410611 Means of egress

341012 Dead ends

341013 Max exit access travel distance

3410614 Elevator control

3410615 Means of egress emergency lighting

3410616 Mixed occupancies

3410617 Automatic sprinklers 7 2 =

3410618 Incidental use

Building score -total value

No applicable value to be inserted

BUILDING SAFETY EVALUATION SCORE (Table 34109)

Formula Table 34107 Table 34108 Score Pass Fail

FS-MFS ~0 (FS) (MFS) = ME-MME 2 0 (ME) (MME) = GS-MGS gt 0 (GS) (MGS) =

FS = Fire Safety MFS = Mandatory Fire Safety ME = Means of Egress MME = Mandatory Means of Egress GS = General Safety MGS = Mandatory General Safety

APPENDICES A- J

Appendices adopted (10121) Compliance verified

12

Page 7: NOTES: N.R. N.A.- Not applicable ADMINISTRATION {Chapter 1) · Mixed Occupancy (508.3) Accessory occupancies (508.3.1) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to

MEANS OF EGRESS (continued)

GENERAL MEANS OF EGRESS

Design requirements (10032- 10037)

Means of egress illumination (1006)

Exit signs (1011)

Accessible means of egress (1 007)

Means of egress doors (10081-100812)

Special doorsGatesTurnstiles (100813 10082 10083)

EXIT ACCESS

Door number and arrangement (10142 10151 10152)

Common path of egress travel (10143)

Exit access travel distance (10161)

EXITS I EXIT DISCHARGE

ExitsExit doors (1018 1019)

Vertical exit enclosures (1020)

Exit passageways (1021)

OTHER MEANS OF EGRESS

Miscellaneous egress requirements (10153- 10156)

Bleachers (102511)

Assembly exits amp egress (10252- 10255)

ACCESSIBILITY (Chapter 11)

Scoping requirements (1103)

Accessible route (1104)

Accessible entrances (1105)

Parking and passenger loading (1106)

Also see Accessibility Plan Review Record

Door landingsThresholdsArrangement (100814 -10081 7)

Door hardware (100818 100819)

Stairways (1009)

Roof access (100911)

Ramps (1010)

Handrails (1012)

Guards (1013)

Aisles (1 0144)

Egress balconies (10145 10163)

Corridors (1017)

Air movement in corridors (10174)

Horizontal exits (1022)

Exterior exit rampsstairways (1023)

Exit discharge (1024)

Assembly aisles amp features (10256- 102515)

Emergency escape and rescue (1026)

Dwelling units and sleeping units (1107)

Special occupancies (1108)

Features and facilities (1109)

Signage (1110)

7

INTERIOR ENVIRONMENT (Chapter 12)

Ventilation openings (1203) Sound transmission (1207)

Temperature control (1204) Interior space dimensions (1208)

Lighting (1205) Access to unoccupied spaces (1209)

Yards or courts (1206) Surrounding materials (1210 2509)

Also see Mechanical Code Plan Review Record

BUILDING ENVELOPE Chapters 13 14 15) See Energy Conservation Code Plan Review Record

EXTERIOR WALLS (Chapter 14)

Performance requirements (1403) Exterior wall coveringsMCMs (1405 1407)

Materials (1404) Combustible material restrictions (1406)

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (Chapter 15)

Weather protection (1503) Materials (1506)

Flashing (15032 150729 150739 Roof coverings (1507) 150756 150776 150787 150798) Roof insulation (1508)

Performance requirements (1504) Rooftop structures (1509)

Fire classification (1505) Reroofing (1510)

STRUCTURAL SYSTEMS Chapters 16 17 18) STRUCTURAL DESIGN (Chapter 16)

STRUCTURAL DESIGN CALCULATIONS Live load reduction (160311 16079 160710)

Submitted for all structural members Roof live loads (160312 160711)(1061 10611)

Roof snow loads (160313 1608 Chapter 7 ofASCE 7) DESIGN LOADS ON CONSTRUCTION DOCUMENTS Ground snow load pg (16082 72 of(1603) ASCE 7)

If pg gt 10 psf flat-roof snow load pr(73 ofUniformly distributed floor live loads (160311 ASCE 7)Table 1607 1)

If pg gt 1 0 psf snow exposure factor Ce Floor Area Use Loads Shown (Table 7-2 731 of ASCE 7)

If pg gt 10 psf snow load importance factor I (733 Table 7-4 ofASCE 7)

Roof thermal factor Ct (Table 7-3 732 of ASCE 7)

Sloped roof snow load Ps (74 ofASCE 7)

8

DESIGN LOADS (continued)

Wind loads (160314 1609 Chapter 6 of ASCE 7)

Design procedure (612 ofASCE 7)

Basic wind speed (16093 Fig 6-1 of ASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Wind importance factor I (Table 6-1 655 ofASCE 7)

Surface roughnessExposure categories (16094 656 ofASCE 7)

Internal pressure coefficient (Fig 6-5 65111 of ASCE 7)

Component and cladding pressures (6142 6422 65124 ofASCE 7)

Main wind-force resisting system (6141 6421 65122 ofASCE 7)

Earthquake design data (160315 1613 Chapter 11- 13 and 15-23 ofASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Seismic importance factor (1151 Table 115-1 ofASCE 7)

Mapped spectral response acceleration Ss and St (161351 1141 of ASCE 7)

Spectral response coefficients Sos amp Sot (161354 1144 ofASCE 7)

Site class (161352 1142 ofASCE 7)

Seismic design category (161356 116 of ASCE 7)

Basic seismic-force-resisting system (Table 122-1 of ASCE 7)

Response modification coefficient R and deflection amplification factor Cd (Table 122-1 ofASCE 7)

Analysis procedure (126 of ASCE 7)

Design base shear (128 of ASCE 7)

Flood loads (160316 1612)

Flood hazard area (16123)

Elevation of structure (16125)

Other loads

Concentrated loads (16074)

Partition loads (16075)

Impact loads (16078)

Misc loads (Table 16076 160761 16077 160712 160713 1610 1611 2404)

QUALITY ASSURANCE (Chapter 17)

ApprovalsResearch report(s )(1703 170342) Report No____

Statement of special inspections (170411 1705)

Prefabricated items (17042)

Steel construction (17043)

Concrete construction (17044)

Masonry construction (17045)

Wood construction (17046)

Prepared fill and foundations

(1704 7 17048 17049)

Sprayed fire-resistant materials and coatings (170410 170411)

EIFS (170412)

Smoke control (170414)

Seismic resistance (1707)

Structural testingObservations (seismic) (1708 1709)

Testing (other) (1710- 1715)

SOILS AND FOUNDATIONS (Chapter 18)

Soils investigationsReports (18021 18022 18026)

Soil classification (18023)

Excavation grading and fill (1803)

Load-bearing values (1804)

Footings and foundations (1805)

Retaining walls (1806)

Dampproofing and waterproofing (1807)

Foundations (other types) (1808 - 1812)

9

STRUCTURAL MATERIALS (Chapters 19 21 22 23) CONCRETE (Chapter 19)

Plain and reinforced concrete Minimum concrete strength designconstruction standard (Table 190422) specified (19012 1908) Cold weather and hot weather construc-

Construction documents (19014) tion specified (190512 190513)

Slab provisions (1910)

MASONRY (Chapter 21) Design method construction standard Cold weather and hot weather construc-

specified (21012) tion specified (21043 21044)

Construction documents (21013) Seismic design (2106)

Construction materials (2103) Glass unit masonry (2110)

Mortar type (21038) FireplacesHeatersChimneys (2111 2112 2113)

STEEL (Chapter 22) Structural steel designconstruction Steel storage racks (2208)

standard specified (2205) Cold-formed steel designconstruction

Open-web steel joist designconstruction standard specified (2209) standard specified (2206)

Cold-formed steel light-framed design Steel cable structures (2207) construction standard specified (2210)

WOOD (Chapter 23) Design method option used (23012) Fasteners and fastening

(23036 23049 Table 230491)MATERIAL STANDARDS I CONSTRUCTION REQUIREMENTS (2303- 2306) Heavy timber construction (230410)

Lumber (230311) Shear walls and diaphragms (2305 2306) Wood -joists (230312)

CONVENTIONAL LIGHT-FRAME CONSTRUCTION Glue-laminated timbers (230313) (2308) Wood structural panels Limitations satisfied (23082)

(230314 23046 2304 7) WindSeismic requirements (230821

Fiber- hard- ampparticle- boards 230822 230811 230812) (2303 1 5 - 2303 1 7)

Braced walls (23083 230893) Decay and termite protection

Foundation anchorage (230318 230411) (230833 23086)

Structural composite lumber (230319) Floor joists (Tables 23088[1] 23088[2])

Structural log members (2303110) Wall studs (Table 230891) Round timber poles and piles Girders (Tables 230895 and 230896

(2303111) 23087)

Fire-retardant-treated wood (23032) Ceiling joists (Tables 2308102[1] 2308102[2])Hardwood and plywood (23033)

Roof rafters (Tables 2308103[1]shyTrusses (23034) 2308103[6])

Joist hangers and connectors (23035) Roof uplift (2308101)

10

NONSTRUCTURAL MATERIALS (Chapters 24 25 26) GLASS AND GLAZING (Chapter 24)

Sloped glazing and skylights (2405) Safety glazing (2406 2407 2408 2409)

GYPSUM BOARD AND PLASTER (Chapter 25)

Gypsum board materials Plaster (2507 2508 2510- 2513)(2506 Table 25062 Table 25081)

PLASTIC (Chapter 26)

FOAM PLASTIC INSULATION (2603) Protection against termites (26038)

Labeling (26032 260356) Special approval (26039)

Surface-burning characteristics MISCELLANEOUS PLASTICS(26033 260354)

Interior finish and trim (2604)Thermal barrier (26034) Plastic veneer (2605)Exterior wallsRoofs (26035 26036) Light-transmitting plastics (2606- 2611)

BUILDING SERVICES (Chapters 27 28 29 30) ELEVATORS AND CONVEYING SYSTEMS (Chapter 30)

Construction standard specified (30012) Hoistway venting (3004)

Hoistway enclosures (3002) Conveying systems (3005)

Opening protectives (300211) Machine rooms (3006)

Emergency operations (3003)

Also see Electrical (Ch27) Mechanical (Ch28) and Plumbing (Ch29) Plan Review Records

SPECIAL DEVICES AND CONDITIONS (Chapters 31 34) SPECIAL CONSTRUCTION Chapter 31)

Membrane structures (3102) PEDESTRIAN WALKWAYS AND TUNNELS (3104)

Awnings and canopiesMarquees Construction and use (31043 31044)(3105 3106)

Separation (31045 310410)Signs (3107)

Public way (31046)Radio and television towers (3108)

Egress (3104 7- 31049)Swimming pool enclosures (3109)

EXISTING STRUCTURES (Chapter 34)

Additions alterations repairs (3403) Accessibility (3409)

Fire escapes (3404) Compliance alternatives (3410)

Change of occupancy (3406)

11

----------------

BUILDING EVALUATION SUMMARY (Table 34107)

Existing occupancy _______________ Proposed occupancy Year building was constructed ____________ Number of stories ______ Height in feet Type of construction Area per floor Percentage of frontage Corridor wall rating _______________ Completely suppressed Yes ___ No Required door closers _____Yes ___No ___ Compartmentation Yes ___ No Fireresistance rating of vertical opening enclosures Type of HVAC system --------------- serving number of floors Automatic fire detection Yes No ___ type and location Fire alarm system Yes ___ No ___ type --------------------Smoke control Yes No ___ type -------------------Adequate exit routes Yes ___ No Dead ends Yes No ___ Maximum exit access travel distance __________ Elevator controls Yes No Means of egress emergency lighting Yes __ No ___ Mixed occupancies Yes No

Safety Fire Means General parameters safety (FS) of egress (ME) safety (GS)

341061 Building height

341062 Building area

341063 Compartmentation

341064 Tenant and dwelling unit separations

341065 Corridor walls

341066 Vertical openings

341067 HVAC systems

341068 Automatic fire detection

341069 Fire alarm system

3410610 Smoke control

3410611 Means of egress

341012 Dead ends

341013 Max exit access travel distance

3410614 Elevator control

3410615 Means of egress emergency lighting

3410616 Mixed occupancies

3410617 Automatic sprinklers 7 2 =

3410618 Incidental use

Building score -total value

No applicable value to be inserted

BUILDING SAFETY EVALUATION SCORE (Table 34109)

Formula Table 34107 Table 34108 Score Pass Fail

FS-MFS ~0 (FS) (MFS) = ME-MME 2 0 (ME) (MME) = GS-MGS gt 0 (GS) (MGS) =

FS = Fire Safety MFS = Mandatory Fire Safety ME = Means of Egress MME = Mandatory Means of Egress GS = General Safety MGS = Mandatory General Safety

APPENDICES A- J

Appendices adopted (10121) Compliance verified

12

Page 8: NOTES: N.R. N.A.- Not applicable ADMINISTRATION {Chapter 1) · Mixed Occupancy (508.3) Accessory occupancies (508.3.1) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to

INTERIOR ENVIRONMENT (Chapter 12)

Ventilation openings (1203) Sound transmission (1207)

Temperature control (1204) Interior space dimensions (1208)

Lighting (1205) Access to unoccupied spaces (1209)

Yards or courts (1206) Surrounding materials (1210 2509)

Also see Mechanical Code Plan Review Record

BUILDING ENVELOPE Chapters 13 14 15) See Energy Conservation Code Plan Review Record

EXTERIOR WALLS (Chapter 14)

Performance requirements (1403) Exterior wall coveringsMCMs (1405 1407)

Materials (1404) Combustible material restrictions (1406)

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (Chapter 15)

Weather protection (1503) Materials (1506)

Flashing (15032 150729 150739 Roof coverings (1507) 150756 150776 150787 150798) Roof insulation (1508)

Performance requirements (1504) Rooftop structures (1509)

Fire classification (1505) Reroofing (1510)

STRUCTURAL SYSTEMS Chapters 16 17 18) STRUCTURAL DESIGN (Chapter 16)

STRUCTURAL DESIGN CALCULATIONS Live load reduction (160311 16079 160710)

Submitted for all structural members Roof live loads (160312 160711)(1061 10611)

Roof snow loads (160313 1608 Chapter 7 ofASCE 7) DESIGN LOADS ON CONSTRUCTION DOCUMENTS Ground snow load pg (16082 72 of(1603) ASCE 7)

If pg gt 10 psf flat-roof snow load pr(73 ofUniformly distributed floor live loads (160311 ASCE 7)Table 1607 1)

If pg gt 1 0 psf snow exposure factor Ce Floor Area Use Loads Shown (Table 7-2 731 of ASCE 7)

If pg gt 10 psf snow load importance factor I (733 Table 7-4 ofASCE 7)

Roof thermal factor Ct (Table 7-3 732 of ASCE 7)

Sloped roof snow load Ps (74 ofASCE 7)

8

DESIGN LOADS (continued)

Wind loads (160314 1609 Chapter 6 of ASCE 7)

Design procedure (612 ofASCE 7)

Basic wind speed (16093 Fig 6-1 of ASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Wind importance factor I (Table 6-1 655 ofASCE 7)

Surface roughnessExposure categories (16094 656 ofASCE 7)

Internal pressure coefficient (Fig 6-5 65111 of ASCE 7)

Component and cladding pressures (6142 6422 65124 ofASCE 7)

Main wind-force resisting system (6141 6421 65122 ofASCE 7)

Earthquake design data (160315 1613 Chapter 11- 13 and 15-23 ofASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Seismic importance factor (1151 Table 115-1 ofASCE 7)

Mapped spectral response acceleration Ss and St (161351 1141 of ASCE 7)

Spectral response coefficients Sos amp Sot (161354 1144 ofASCE 7)

Site class (161352 1142 ofASCE 7)

Seismic design category (161356 116 of ASCE 7)

Basic seismic-force-resisting system (Table 122-1 of ASCE 7)

Response modification coefficient R and deflection amplification factor Cd (Table 122-1 ofASCE 7)

Analysis procedure (126 of ASCE 7)

Design base shear (128 of ASCE 7)

Flood loads (160316 1612)

Flood hazard area (16123)

Elevation of structure (16125)

Other loads

Concentrated loads (16074)

Partition loads (16075)

Impact loads (16078)

Misc loads (Table 16076 160761 16077 160712 160713 1610 1611 2404)

QUALITY ASSURANCE (Chapter 17)

ApprovalsResearch report(s )(1703 170342) Report No____

Statement of special inspections (170411 1705)

Prefabricated items (17042)

Steel construction (17043)

Concrete construction (17044)

Masonry construction (17045)

Wood construction (17046)

Prepared fill and foundations

(1704 7 17048 17049)

Sprayed fire-resistant materials and coatings (170410 170411)

EIFS (170412)

Smoke control (170414)

Seismic resistance (1707)

Structural testingObservations (seismic) (1708 1709)

Testing (other) (1710- 1715)

SOILS AND FOUNDATIONS (Chapter 18)

Soils investigationsReports (18021 18022 18026)

Soil classification (18023)

Excavation grading and fill (1803)

Load-bearing values (1804)

Footings and foundations (1805)

Retaining walls (1806)

Dampproofing and waterproofing (1807)

Foundations (other types) (1808 - 1812)

9

STRUCTURAL MATERIALS (Chapters 19 21 22 23) CONCRETE (Chapter 19)

Plain and reinforced concrete Minimum concrete strength designconstruction standard (Table 190422) specified (19012 1908) Cold weather and hot weather construc-

Construction documents (19014) tion specified (190512 190513)

Slab provisions (1910)

MASONRY (Chapter 21) Design method construction standard Cold weather and hot weather construc-

specified (21012) tion specified (21043 21044)

Construction documents (21013) Seismic design (2106)

Construction materials (2103) Glass unit masonry (2110)

Mortar type (21038) FireplacesHeatersChimneys (2111 2112 2113)

STEEL (Chapter 22) Structural steel designconstruction Steel storage racks (2208)

standard specified (2205) Cold-formed steel designconstruction

Open-web steel joist designconstruction standard specified (2209) standard specified (2206)

Cold-formed steel light-framed design Steel cable structures (2207) construction standard specified (2210)

WOOD (Chapter 23) Design method option used (23012) Fasteners and fastening

(23036 23049 Table 230491)MATERIAL STANDARDS I CONSTRUCTION REQUIREMENTS (2303- 2306) Heavy timber construction (230410)

Lumber (230311) Shear walls and diaphragms (2305 2306) Wood -joists (230312)

CONVENTIONAL LIGHT-FRAME CONSTRUCTION Glue-laminated timbers (230313) (2308) Wood structural panels Limitations satisfied (23082)

(230314 23046 2304 7) WindSeismic requirements (230821

Fiber- hard- ampparticle- boards 230822 230811 230812) (2303 1 5 - 2303 1 7)

Braced walls (23083 230893) Decay and termite protection

Foundation anchorage (230318 230411) (230833 23086)

Structural composite lumber (230319) Floor joists (Tables 23088[1] 23088[2])

Structural log members (2303110) Wall studs (Table 230891) Round timber poles and piles Girders (Tables 230895 and 230896

(2303111) 23087)

Fire-retardant-treated wood (23032) Ceiling joists (Tables 2308102[1] 2308102[2])Hardwood and plywood (23033)

Roof rafters (Tables 2308103[1]shyTrusses (23034) 2308103[6])

Joist hangers and connectors (23035) Roof uplift (2308101)

10

NONSTRUCTURAL MATERIALS (Chapters 24 25 26) GLASS AND GLAZING (Chapter 24)

Sloped glazing and skylights (2405) Safety glazing (2406 2407 2408 2409)

GYPSUM BOARD AND PLASTER (Chapter 25)

Gypsum board materials Plaster (2507 2508 2510- 2513)(2506 Table 25062 Table 25081)

PLASTIC (Chapter 26)

FOAM PLASTIC INSULATION (2603) Protection against termites (26038)

Labeling (26032 260356) Special approval (26039)

Surface-burning characteristics MISCELLANEOUS PLASTICS(26033 260354)

Interior finish and trim (2604)Thermal barrier (26034) Plastic veneer (2605)Exterior wallsRoofs (26035 26036) Light-transmitting plastics (2606- 2611)

BUILDING SERVICES (Chapters 27 28 29 30) ELEVATORS AND CONVEYING SYSTEMS (Chapter 30)

Construction standard specified (30012) Hoistway venting (3004)

Hoistway enclosures (3002) Conveying systems (3005)

Opening protectives (300211) Machine rooms (3006)

Emergency operations (3003)

Also see Electrical (Ch27) Mechanical (Ch28) and Plumbing (Ch29) Plan Review Records

SPECIAL DEVICES AND CONDITIONS (Chapters 31 34) SPECIAL CONSTRUCTION Chapter 31)

Membrane structures (3102) PEDESTRIAN WALKWAYS AND TUNNELS (3104)

Awnings and canopiesMarquees Construction and use (31043 31044)(3105 3106)

Separation (31045 310410)Signs (3107)

Public way (31046)Radio and television towers (3108)

Egress (3104 7- 31049)Swimming pool enclosures (3109)

EXISTING STRUCTURES (Chapter 34)

Additions alterations repairs (3403) Accessibility (3409)

Fire escapes (3404) Compliance alternatives (3410)

Change of occupancy (3406)

11

----------------

BUILDING EVALUATION SUMMARY (Table 34107)

Existing occupancy _______________ Proposed occupancy Year building was constructed ____________ Number of stories ______ Height in feet Type of construction Area per floor Percentage of frontage Corridor wall rating _______________ Completely suppressed Yes ___ No Required door closers _____Yes ___No ___ Compartmentation Yes ___ No Fireresistance rating of vertical opening enclosures Type of HVAC system --------------- serving number of floors Automatic fire detection Yes No ___ type and location Fire alarm system Yes ___ No ___ type --------------------Smoke control Yes No ___ type -------------------Adequate exit routes Yes ___ No Dead ends Yes No ___ Maximum exit access travel distance __________ Elevator controls Yes No Means of egress emergency lighting Yes __ No ___ Mixed occupancies Yes No

Safety Fire Means General parameters safety (FS) of egress (ME) safety (GS)

341061 Building height

341062 Building area

341063 Compartmentation

341064 Tenant and dwelling unit separations

341065 Corridor walls

341066 Vertical openings

341067 HVAC systems

341068 Automatic fire detection

341069 Fire alarm system

3410610 Smoke control

3410611 Means of egress

341012 Dead ends

341013 Max exit access travel distance

3410614 Elevator control

3410615 Means of egress emergency lighting

3410616 Mixed occupancies

3410617 Automatic sprinklers 7 2 =

3410618 Incidental use

Building score -total value

No applicable value to be inserted

BUILDING SAFETY EVALUATION SCORE (Table 34109)

Formula Table 34107 Table 34108 Score Pass Fail

FS-MFS ~0 (FS) (MFS) = ME-MME 2 0 (ME) (MME) = GS-MGS gt 0 (GS) (MGS) =

FS = Fire Safety MFS = Mandatory Fire Safety ME = Means of Egress MME = Mandatory Means of Egress GS = General Safety MGS = Mandatory General Safety

APPENDICES A- J

Appendices adopted (10121) Compliance verified

12

Page 9: NOTES: N.R. N.A.- Not applicable ADMINISTRATION {Chapter 1) · Mixed Occupancy (508.3) Accessory occupancies (508.3.1) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to

DESIGN LOADS (continued)

Wind loads (160314 1609 Chapter 6 of ASCE 7)

Design procedure (612 ofASCE 7)

Basic wind speed (16093 Fig 6-1 of ASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Wind importance factor I (Table 6-1 655 ofASCE 7)

Surface roughnessExposure categories (16094 656 ofASCE 7)

Internal pressure coefficient (Fig 6-5 65111 of ASCE 7)

Component and cladding pressures (6142 6422 65124 ofASCE 7)

Main wind-force resisting system (6141 6421 65122 ofASCE 7)

Earthquake design data (160315 1613 Chapter 11- 13 and 15-23 ofASCE 7)

Occupancy category (Table 16045 Table 1-1 of ASCE 7)

Seismic importance factor (1151 Table 115-1 ofASCE 7)

Mapped spectral response acceleration Ss and St (161351 1141 of ASCE 7)

Spectral response coefficients Sos amp Sot (161354 1144 ofASCE 7)

Site class (161352 1142 ofASCE 7)

Seismic design category (161356 116 of ASCE 7)

Basic seismic-force-resisting system (Table 122-1 of ASCE 7)

Response modification coefficient R and deflection amplification factor Cd (Table 122-1 ofASCE 7)

Analysis procedure (126 of ASCE 7)

Design base shear (128 of ASCE 7)

Flood loads (160316 1612)

Flood hazard area (16123)

Elevation of structure (16125)

Other loads

Concentrated loads (16074)

Partition loads (16075)

Impact loads (16078)

Misc loads (Table 16076 160761 16077 160712 160713 1610 1611 2404)

QUALITY ASSURANCE (Chapter 17)

ApprovalsResearch report(s )(1703 170342) Report No____

Statement of special inspections (170411 1705)

Prefabricated items (17042)

Steel construction (17043)

Concrete construction (17044)

Masonry construction (17045)

Wood construction (17046)

Prepared fill and foundations

(1704 7 17048 17049)

Sprayed fire-resistant materials and coatings (170410 170411)

EIFS (170412)

Smoke control (170414)

Seismic resistance (1707)

Structural testingObservations (seismic) (1708 1709)

Testing (other) (1710- 1715)

SOILS AND FOUNDATIONS (Chapter 18)

Soils investigationsReports (18021 18022 18026)

Soil classification (18023)

Excavation grading and fill (1803)

Load-bearing values (1804)

Footings and foundations (1805)

Retaining walls (1806)

Dampproofing and waterproofing (1807)

Foundations (other types) (1808 - 1812)

9

STRUCTURAL MATERIALS (Chapters 19 21 22 23) CONCRETE (Chapter 19)

Plain and reinforced concrete Minimum concrete strength designconstruction standard (Table 190422) specified (19012 1908) Cold weather and hot weather construc-

Construction documents (19014) tion specified (190512 190513)

Slab provisions (1910)

MASONRY (Chapter 21) Design method construction standard Cold weather and hot weather construc-

specified (21012) tion specified (21043 21044)

Construction documents (21013) Seismic design (2106)

Construction materials (2103) Glass unit masonry (2110)

Mortar type (21038) FireplacesHeatersChimneys (2111 2112 2113)

STEEL (Chapter 22) Structural steel designconstruction Steel storage racks (2208)

standard specified (2205) Cold-formed steel designconstruction

Open-web steel joist designconstruction standard specified (2209) standard specified (2206)

Cold-formed steel light-framed design Steel cable structures (2207) construction standard specified (2210)

WOOD (Chapter 23) Design method option used (23012) Fasteners and fastening

(23036 23049 Table 230491)MATERIAL STANDARDS I CONSTRUCTION REQUIREMENTS (2303- 2306) Heavy timber construction (230410)

Lumber (230311) Shear walls and diaphragms (2305 2306) Wood -joists (230312)

CONVENTIONAL LIGHT-FRAME CONSTRUCTION Glue-laminated timbers (230313) (2308) Wood structural panels Limitations satisfied (23082)

(230314 23046 2304 7) WindSeismic requirements (230821

Fiber- hard- ampparticle- boards 230822 230811 230812) (2303 1 5 - 2303 1 7)

Braced walls (23083 230893) Decay and termite protection

Foundation anchorage (230318 230411) (230833 23086)

Structural composite lumber (230319) Floor joists (Tables 23088[1] 23088[2])

Structural log members (2303110) Wall studs (Table 230891) Round timber poles and piles Girders (Tables 230895 and 230896

(2303111) 23087)

Fire-retardant-treated wood (23032) Ceiling joists (Tables 2308102[1] 2308102[2])Hardwood and plywood (23033)

Roof rafters (Tables 2308103[1]shyTrusses (23034) 2308103[6])

Joist hangers and connectors (23035) Roof uplift (2308101)

10

NONSTRUCTURAL MATERIALS (Chapters 24 25 26) GLASS AND GLAZING (Chapter 24)

Sloped glazing and skylights (2405) Safety glazing (2406 2407 2408 2409)

GYPSUM BOARD AND PLASTER (Chapter 25)

Gypsum board materials Plaster (2507 2508 2510- 2513)(2506 Table 25062 Table 25081)

PLASTIC (Chapter 26)

FOAM PLASTIC INSULATION (2603) Protection against termites (26038)

Labeling (26032 260356) Special approval (26039)

Surface-burning characteristics MISCELLANEOUS PLASTICS(26033 260354)

Interior finish and trim (2604)Thermal barrier (26034) Plastic veneer (2605)Exterior wallsRoofs (26035 26036) Light-transmitting plastics (2606- 2611)

BUILDING SERVICES (Chapters 27 28 29 30) ELEVATORS AND CONVEYING SYSTEMS (Chapter 30)

Construction standard specified (30012) Hoistway venting (3004)

Hoistway enclosures (3002) Conveying systems (3005)

Opening protectives (300211) Machine rooms (3006)

Emergency operations (3003)

Also see Electrical (Ch27) Mechanical (Ch28) and Plumbing (Ch29) Plan Review Records

SPECIAL DEVICES AND CONDITIONS (Chapters 31 34) SPECIAL CONSTRUCTION Chapter 31)

Membrane structures (3102) PEDESTRIAN WALKWAYS AND TUNNELS (3104)

Awnings and canopiesMarquees Construction and use (31043 31044)(3105 3106)

Separation (31045 310410)Signs (3107)

Public way (31046)Radio and television towers (3108)

Egress (3104 7- 31049)Swimming pool enclosures (3109)

EXISTING STRUCTURES (Chapter 34)

Additions alterations repairs (3403) Accessibility (3409)

Fire escapes (3404) Compliance alternatives (3410)

Change of occupancy (3406)

11

----------------

BUILDING EVALUATION SUMMARY (Table 34107)

Existing occupancy _______________ Proposed occupancy Year building was constructed ____________ Number of stories ______ Height in feet Type of construction Area per floor Percentage of frontage Corridor wall rating _______________ Completely suppressed Yes ___ No Required door closers _____Yes ___No ___ Compartmentation Yes ___ No Fireresistance rating of vertical opening enclosures Type of HVAC system --------------- serving number of floors Automatic fire detection Yes No ___ type and location Fire alarm system Yes ___ No ___ type --------------------Smoke control Yes No ___ type -------------------Adequate exit routes Yes ___ No Dead ends Yes No ___ Maximum exit access travel distance __________ Elevator controls Yes No Means of egress emergency lighting Yes __ No ___ Mixed occupancies Yes No

Safety Fire Means General parameters safety (FS) of egress (ME) safety (GS)

341061 Building height

341062 Building area

341063 Compartmentation

341064 Tenant and dwelling unit separations

341065 Corridor walls

341066 Vertical openings

341067 HVAC systems

341068 Automatic fire detection

341069 Fire alarm system

3410610 Smoke control

3410611 Means of egress

341012 Dead ends

341013 Max exit access travel distance

3410614 Elevator control

3410615 Means of egress emergency lighting

3410616 Mixed occupancies

3410617 Automatic sprinklers 7 2 =

3410618 Incidental use

Building score -total value

No applicable value to be inserted

BUILDING SAFETY EVALUATION SCORE (Table 34109)

Formula Table 34107 Table 34108 Score Pass Fail

FS-MFS ~0 (FS) (MFS) = ME-MME 2 0 (ME) (MME) = GS-MGS gt 0 (GS) (MGS) =

FS = Fire Safety MFS = Mandatory Fire Safety ME = Means of Egress MME = Mandatory Means of Egress GS = General Safety MGS = Mandatory General Safety

APPENDICES A- J

Appendices adopted (10121) Compliance verified

12

Page 10: NOTES: N.R. N.A.- Not applicable ADMINISTRATION {Chapter 1) · Mixed Occupancy (508.3) Accessory occupancies (508.3.1) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to

STRUCTURAL MATERIALS (Chapters 19 21 22 23) CONCRETE (Chapter 19)

Plain and reinforced concrete Minimum concrete strength designconstruction standard (Table 190422) specified (19012 1908) Cold weather and hot weather construc-

Construction documents (19014) tion specified (190512 190513)

Slab provisions (1910)

MASONRY (Chapter 21) Design method construction standard Cold weather and hot weather construc-

specified (21012) tion specified (21043 21044)

Construction documents (21013) Seismic design (2106)

Construction materials (2103) Glass unit masonry (2110)

Mortar type (21038) FireplacesHeatersChimneys (2111 2112 2113)

STEEL (Chapter 22) Structural steel designconstruction Steel storage racks (2208)

standard specified (2205) Cold-formed steel designconstruction

Open-web steel joist designconstruction standard specified (2209) standard specified (2206)

Cold-formed steel light-framed design Steel cable structures (2207) construction standard specified (2210)

WOOD (Chapter 23) Design method option used (23012) Fasteners and fastening

(23036 23049 Table 230491)MATERIAL STANDARDS I CONSTRUCTION REQUIREMENTS (2303- 2306) Heavy timber construction (230410)

Lumber (230311) Shear walls and diaphragms (2305 2306) Wood -joists (230312)

CONVENTIONAL LIGHT-FRAME CONSTRUCTION Glue-laminated timbers (230313) (2308) Wood structural panels Limitations satisfied (23082)

(230314 23046 2304 7) WindSeismic requirements (230821

Fiber- hard- ampparticle- boards 230822 230811 230812) (2303 1 5 - 2303 1 7)

Braced walls (23083 230893) Decay and termite protection

Foundation anchorage (230318 230411) (230833 23086)

Structural composite lumber (230319) Floor joists (Tables 23088[1] 23088[2])

Structural log members (2303110) Wall studs (Table 230891) Round timber poles and piles Girders (Tables 230895 and 230896

(2303111) 23087)

Fire-retardant-treated wood (23032) Ceiling joists (Tables 2308102[1] 2308102[2])Hardwood and plywood (23033)

Roof rafters (Tables 2308103[1]shyTrusses (23034) 2308103[6])

Joist hangers and connectors (23035) Roof uplift (2308101)

10

NONSTRUCTURAL MATERIALS (Chapters 24 25 26) GLASS AND GLAZING (Chapter 24)

Sloped glazing and skylights (2405) Safety glazing (2406 2407 2408 2409)

GYPSUM BOARD AND PLASTER (Chapter 25)

Gypsum board materials Plaster (2507 2508 2510- 2513)(2506 Table 25062 Table 25081)

PLASTIC (Chapter 26)

FOAM PLASTIC INSULATION (2603) Protection against termites (26038)

Labeling (26032 260356) Special approval (26039)

Surface-burning characteristics MISCELLANEOUS PLASTICS(26033 260354)

Interior finish and trim (2604)Thermal barrier (26034) Plastic veneer (2605)Exterior wallsRoofs (26035 26036) Light-transmitting plastics (2606- 2611)

BUILDING SERVICES (Chapters 27 28 29 30) ELEVATORS AND CONVEYING SYSTEMS (Chapter 30)

Construction standard specified (30012) Hoistway venting (3004)

Hoistway enclosures (3002) Conveying systems (3005)

Opening protectives (300211) Machine rooms (3006)

Emergency operations (3003)

Also see Electrical (Ch27) Mechanical (Ch28) and Plumbing (Ch29) Plan Review Records

SPECIAL DEVICES AND CONDITIONS (Chapters 31 34) SPECIAL CONSTRUCTION Chapter 31)

Membrane structures (3102) PEDESTRIAN WALKWAYS AND TUNNELS (3104)

Awnings and canopiesMarquees Construction and use (31043 31044)(3105 3106)

Separation (31045 310410)Signs (3107)

Public way (31046)Radio and television towers (3108)

Egress (3104 7- 31049)Swimming pool enclosures (3109)

EXISTING STRUCTURES (Chapter 34)

Additions alterations repairs (3403) Accessibility (3409)

Fire escapes (3404) Compliance alternatives (3410)

Change of occupancy (3406)

11

----------------

BUILDING EVALUATION SUMMARY (Table 34107)

Existing occupancy _______________ Proposed occupancy Year building was constructed ____________ Number of stories ______ Height in feet Type of construction Area per floor Percentage of frontage Corridor wall rating _______________ Completely suppressed Yes ___ No Required door closers _____Yes ___No ___ Compartmentation Yes ___ No Fireresistance rating of vertical opening enclosures Type of HVAC system --------------- serving number of floors Automatic fire detection Yes No ___ type and location Fire alarm system Yes ___ No ___ type --------------------Smoke control Yes No ___ type -------------------Adequate exit routes Yes ___ No Dead ends Yes No ___ Maximum exit access travel distance __________ Elevator controls Yes No Means of egress emergency lighting Yes __ No ___ Mixed occupancies Yes No

Safety Fire Means General parameters safety (FS) of egress (ME) safety (GS)

341061 Building height

341062 Building area

341063 Compartmentation

341064 Tenant and dwelling unit separations

341065 Corridor walls

341066 Vertical openings

341067 HVAC systems

341068 Automatic fire detection

341069 Fire alarm system

3410610 Smoke control

3410611 Means of egress

341012 Dead ends

341013 Max exit access travel distance

3410614 Elevator control

3410615 Means of egress emergency lighting

3410616 Mixed occupancies

3410617 Automatic sprinklers 7 2 =

3410618 Incidental use

Building score -total value

No applicable value to be inserted

BUILDING SAFETY EVALUATION SCORE (Table 34109)

Formula Table 34107 Table 34108 Score Pass Fail

FS-MFS ~0 (FS) (MFS) = ME-MME 2 0 (ME) (MME) = GS-MGS gt 0 (GS) (MGS) =

FS = Fire Safety MFS = Mandatory Fire Safety ME = Means of Egress MME = Mandatory Means of Egress GS = General Safety MGS = Mandatory General Safety

APPENDICES A- J

Appendices adopted (10121) Compliance verified

12

Page 11: NOTES: N.R. N.A.- Not applicable ADMINISTRATION {Chapter 1) · Mixed Occupancy (508.3) Accessory occupancies (508.3.1) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to

NONSTRUCTURAL MATERIALS (Chapters 24 25 26) GLASS AND GLAZING (Chapter 24)

Sloped glazing and skylights (2405) Safety glazing (2406 2407 2408 2409)

GYPSUM BOARD AND PLASTER (Chapter 25)

Gypsum board materials Plaster (2507 2508 2510- 2513)(2506 Table 25062 Table 25081)

PLASTIC (Chapter 26)

FOAM PLASTIC INSULATION (2603) Protection against termites (26038)

Labeling (26032 260356) Special approval (26039)

Surface-burning characteristics MISCELLANEOUS PLASTICS(26033 260354)

Interior finish and trim (2604)Thermal barrier (26034) Plastic veneer (2605)Exterior wallsRoofs (26035 26036) Light-transmitting plastics (2606- 2611)

BUILDING SERVICES (Chapters 27 28 29 30) ELEVATORS AND CONVEYING SYSTEMS (Chapter 30)

Construction standard specified (30012) Hoistway venting (3004)

Hoistway enclosures (3002) Conveying systems (3005)

Opening protectives (300211) Machine rooms (3006)

Emergency operations (3003)

Also see Electrical (Ch27) Mechanical (Ch28) and Plumbing (Ch29) Plan Review Records

SPECIAL DEVICES AND CONDITIONS (Chapters 31 34) SPECIAL CONSTRUCTION Chapter 31)

Membrane structures (3102) PEDESTRIAN WALKWAYS AND TUNNELS (3104)

Awnings and canopiesMarquees Construction and use (31043 31044)(3105 3106)

Separation (31045 310410)Signs (3107)

Public way (31046)Radio and television towers (3108)

Egress (3104 7- 31049)Swimming pool enclosures (3109)

EXISTING STRUCTURES (Chapter 34)

Additions alterations repairs (3403) Accessibility (3409)

Fire escapes (3404) Compliance alternatives (3410)

Change of occupancy (3406)

11

----------------

BUILDING EVALUATION SUMMARY (Table 34107)

Existing occupancy _______________ Proposed occupancy Year building was constructed ____________ Number of stories ______ Height in feet Type of construction Area per floor Percentage of frontage Corridor wall rating _______________ Completely suppressed Yes ___ No Required door closers _____Yes ___No ___ Compartmentation Yes ___ No Fireresistance rating of vertical opening enclosures Type of HVAC system --------------- serving number of floors Automatic fire detection Yes No ___ type and location Fire alarm system Yes ___ No ___ type --------------------Smoke control Yes No ___ type -------------------Adequate exit routes Yes ___ No Dead ends Yes No ___ Maximum exit access travel distance __________ Elevator controls Yes No Means of egress emergency lighting Yes __ No ___ Mixed occupancies Yes No

Safety Fire Means General parameters safety (FS) of egress (ME) safety (GS)

341061 Building height

341062 Building area

341063 Compartmentation

341064 Tenant and dwelling unit separations

341065 Corridor walls

341066 Vertical openings

341067 HVAC systems

341068 Automatic fire detection

341069 Fire alarm system

3410610 Smoke control

3410611 Means of egress

341012 Dead ends

341013 Max exit access travel distance

3410614 Elevator control

3410615 Means of egress emergency lighting

3410616 Mixed occupancies

3410617 Automatic sprinklers 7 2 =

3410618 Incidental use

Building score -total value

No applicable value to be inserted

BUILDING SAFETY EVALUATION SCORE (Table 34109)

Formula Table 34107 Table 34108 Score Pass Fail

FS-MFS ~0 (FS) (MFS) = ME-MME 2 0 (ME) (MME) = GS-MGS gt 0 (GS) (MGS) =

FS = Fire Safety MFS = Mandatory Fire Safety ME = Means of Egress MME = Mandatory Means of Egress GS = General Safety MGS = Mandatory General Safety

APPENDICES A- J

Appendices adopted (10121) Compliance verified

12

Page 12: NOTES: N.R. N.A.- Not applicable ADMINISTRATION {Chapter 1) · Mixed Occupancy (508.3) Accessory occupancies (508.3.1) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to

----------------

BUILDING EVALUATION SUMMARY (Table 34107)

Existing occupancy _______________ Proposed occupancy Year building was constructed ____________ Number of stories ______ Height in feet Type of construction Area per floor Percentage of frontage Corridor wall rating _______________ Completely suppressed Yes ___ No Required door closers _____Yes ___No ___ Compartmentation Yes ___ No Fireresistance rating of vertical opening enclosures Type of HVAC system --------------- serving number of floors Automatic fire detection Yes No ___ type and location Fire alarm system Yes ___ No ___ type --------------------Smoke control Yes No ___ type -------------------Adequate exit routes Yes ___ No Dead ends Yes No ___ Maximum exit access travel distance __________ Elevator controls Yes No Means of egress emergency lighting Yes __ No ___ Mixed occupancies Yes No

Safety Fire Means General parameters safety (FS) of egress (ME) safety (GS)

341061 Building height

341062 Building area

341063 Compartmentation

341064 Tenant and dwelling unit separations

341065 Corridor walls

341066 Vertical openings

341067 HVAC systems

341068 Automatic fire detection

341069 Fire alarm system

3410610 Smoke control

3410611 Means of egress

341012 Dead ends

341013 Max exit access travel distance

3410614 Elevator control

3410615 Means of egress emergency lighting

3410616 Mixed occupancies

3410617 Automatic sprinklers 7 2 =

3410618 Incidental use

Building score -total value

No applicable value to be inserted

BUILDING SAFETY EVALUATION SCORE (Table 34109)

Formula Table 34107 Table 34108 Score Pass Fail

FS-MFS ~0 (FS) (MFS) = ME-MME 2 0 (ME) (MME) = GS-MGS gt 0 (GS) (MGS) =

FS = Fire Safety MFS = Mandatory Fire Safety ME = Means of Egress MME = Mandatory Means of Egress GS = General Safety MGS = Mandatory General Safety

APPENDICES A- J

Appendices adopted (10121) Compliance verified