np 211 belden cable - salesmanagementplus.com · this construction feature affixes the conductor...

8
Belden Expands the DataTuff ® Category 5e And 6 Ethernet Cable Line With Additional 2- and 4-Pair Category 5e Cables The reliability of your Industrial Ethernet network depends on the cable infrastructure: Data transmission errors can lead to interruptions in critical control functions resulting in lost production time and even safety issues. To help ensure optimum factory floor performance, Belden CDT Electronics Division has consistently built both quality and reliability into each cable it manufactures. From the introduction and dominant call-out of Belden’s Blue Hose® cables, to our present line of DataTuff Category 6 and 5e copper cables and TrayOptic® fiber optic Industrial Ethernet cables, Belden has always supplied the cable you need, when you need it. And because we have been at the forefront of the industrial marketplace for decades and understand the rigors of the industrial environment, we also have the unique ability to provide top performing cables — regardless of the work environment. So, even if your cabling system is exposed to the following conditions you can turn to Belden for the right solution: > Oil, sunlight and gasoline > Temperature variations > Abrasion and crushing > Presence of EMI/RFI (electromagnetic interference or radio frequency interference) Only DataTuff Cables with Belden's Patented Bonded-Pair Technology Offer The Benefit of Installable Performance Many versions of DataTuff cables feature Belden’s patented Bonded-Pair technology. This construction feature affixes the conductor insulation of the cable pairs along their longitudinal axes to ensure that no performance-robbing gaps can develop between the conductor pairs. Since no gaps can occur, and the conductor-to-conductor spacing, or centricity, is always uniform, the cable offers excellent and consistently reliable electrical performance — even after the cable has been subjected to the bending, pulling and twisting that is inherent in the installation process. Belden calls this unique after-installation performance capability Installable Performance. BELDEN Cable TM NEW PRODUCT BULLETIN NP 211 Whether you specify copper or fiber optic cables, peak network efficiency and reliability are achieved with Belden ® DataTuff ® Industrial Ethernet cables. Bonded-Pair UTP and ScTP versions also offer Installable Performance. ® NP 211

Upload: nguyenthuan

Post on 29-Aug-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NP 211 BELDEN Cable - salesmanagementplus.com · This construction feature affixes the conductor ... CEC: CMR FT4 †2000 ft ... 4 1000 304.8 30.0 13.6 .242 6.15 Flexible CMR, 2000

Belden Expands the DataTuff® Category 5e And 6 Ethernet Cable Line With Additional 2- and 4-Pair Category 5e Cables

The reliability of your Industrial Ethernet network depends on the cable infrastructure:Data transmission errors can lead to interruptions in critical control functionsresulting in lost production time and evensafety issues. To help ensure optimum factoryfloor performance, Belden CDT ElectronicsDivision has consistently built both quality and reliability into each cable it manufactures.From the introduction and dominant call-outof Belden’s Blue Hose® cables, to our presentline of DataTuff Category 6 and 5e coppercables and TrayOptic® fiber optic IndustrialEthernet cables, Belden has always suppliedthe cable you need, when you need it.

And because we have been at the forefrontof the industrial marketplace for decades and understand the rigors of the industrialenvironment, we also have the unique abilityto provide top performing cables — regardlessof the work environment. So, even if yourcabling system is exposed to the followingconditions you can turn to Belden for theright solution:

> Oil, sunlight and gasoline

> Temperature variations

> Abrasion and crushing

> Presence of EMI/RFI (electromagnetic interference or radio frequency interference)

Only DataTuff Cables with Belden'sPatented Bonded-Pair Technology OfferThe Benefit of Installable Performance

Many versions of DataTuff cables featureBelden’s patented Bonded-Pair technology.This construction feature affixes the conductorinsulation of the cable pairs along their longitudinal axes to ensure that no performance-robbing gaps can developbetween the conductor pairs. Since no gapscan occur, and the conductor-to-conductorspacing, or centricity, is always uniform, the cable offers excellent and consistentlyreliable electrical performance — even after the cable has been subjected to the bending,pulling and twisting that is inherent in theinstallation process. Belden calls this uniqueafter-installation performance capabilityInstallable Performance.

BELDENCableTMN

EW

PR

OD

UC

T

BULL

ETIN

NP 211

Whether you specify copper or

fiber optic cables, peak network

efficiency and reliability are

achieved with Belden® DataTuff®

Industrial Ethernet cables.

Bonded-Pair UTP and ScTP versions

also offer Installable Performance.®

NP 211

Page 2: NP 211 BELDEN Cable - salesmanagementplus.com · This construction feature affixes the conductor ... CEC: CMR FT4 †2000 ft ... 4 1000 304.8 30.0 13.6 .242 6.15 Flexible CMR, 2000

Additionally, when the unbonded-pairsgap, an impedance mismatch occurs.When the transmitted signal encountersthis mismatch, portions of the signalare reflected back toward the receiver.This is called return loss, or RL. A cablewith poor RL values can significantlyimpact the performance of an activenetwork, reduce network efficiency and lead to excessive bit error rates.

In tests performed by Belden that simulate the effects of the installationprocess, both an industry-leading 350 MHz Cat 5e cable (an unbonded-pair cable) and a Belden 350 MHz Cat 5e Bonded-Pair cable were testedright off the reel and then for the sakeof comparison, they were subjected toan Installation Stress Test. This StressTest simulated just some of the stressesthat a cable experiences as it is installed(being bent around corners, creating aservice loop and being stuffed into anoutlet box). The results? The unbonded-pair cable showed an RL degradation ofmore than 12 dB — more than 15 timesworse its before-installation value. TheBonded-Pair cables showed little changein RL performance. (For more detailedinformation, request the Technical BulletinTB-66 “The Impact of Installation Stresseson Cable Performance.”)

TrayOptic® Cables Feature Laser Certified Fiber (LCFÍ) and Water-Blocking Capability

When the installation demands thecombination of sophisticated fiber optictechnology and rugged durability, lookto Belden’s line of TrayOptic indoor/outdoor fiber optic cables — nowupgraded to include a water-blockingagent. All TrayOptic products also utilizeLaser Certified Fiber to handle GigabitEthernet light sources and any expandedbandwidth requirements. For informationon Belden’s full line of BelOptix® fiberoptic cables, including TrayOptic cables,contact Belden CDT Electronics Divisionat 1-800-BELDEN-4 or visitwww.belden.com.

Quality You Can Trust

All Belden products are manufacturedto the industry’s highest standards ofquality, utilizing the most advancedequipment, systems, controls andprocesses. In fact, Belden has long been a pioneer in production processes,such as statistical process control (SPC), that have become industry standards. And Belden was the firstmajor designer and manufacturer ofcable products to achieve ISO 9000registration for the majority of itsdomestic and overseas facilities.

Belden Quality Means Uptime andSuperior Safety Performance

Today's critical industrial networkingapplications can't afford data transmission errors that can causedowntime, delays, and even safety concerns. Belden quality gives you the performance and reliability youneed on a day-by-day basis.

Initial Installed

Industry 350 MHz Unbonded-PairCat 5e Cable Return Loss Margins

(20–100 MHz)

Mar

gin

(dB)

Fail

SpecLimit

-6-4-202468

101214

High

er is

bet

ter

Initial Installed

Belden 350 MHz Bonded-PairCat 5e Cable Return Loss Margins

(20–100 MHz)

Mar

gin

(dB)

SpecLimit

-6-4-202468

101214

High

er is

bet

ter

Blue Orange Green Brown

Data Pairs

Installed and manipulated unbonded-pairs(left) have a tendency to gap, varying thecentricity of the two conductors. Bonded-Pairs (right) do not gap so the physicalintegrity of the pair is maintained.

In an Installation Stress Test that simulates the installation process, the Cat 5e unbonded-paircables (left) showed an RL degradation of more than 12 dB. The Bonded-Pair cables (right)exhibited little change in RL performance.

Bonded-PairUnbonded-Pair

Page 3: NP 211 BELDEN Cable - salesmanagementplus.com · This construction feature affixes the conductor ... CEC: CMR FT4 †2000 ft ... 4 1000 304.8 30.0 13.6 .242 6.15 Flexible CMR, 2000

Nominal OD

Cat 5e • 24 AWG Bonded-Pairs Solid BC • Overall Beldfoil® Shield • Drain Wire • See Color Code Chart (Reference Pair No. 2 and 3)

Non-Plenum • Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant Black or Teal PVC Jacket7933A NEC: 2 1000 304.8 32.0 14.5 .227 5.77

Compliant u CMR 2000† 609.6 64.8 29.4CEC:

CMR FT4

†2000 ft. put-up available in Black only.Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C*RJ-45 Compatible • U.S. Patents 5,606,151 and 5,734,126 • Cable passes -40°C Cold Bend per UL1581Jacket sequentially marked at 2 ft. intervals. • Third party verified to TIA/EIA-568-B.2, Category 5e • Shield is bonded to jacket inner wall for electrical stability.

StandardUnit Wt.

Lbs. kg Inch mm

PartNo.Description

Standard Lengths

Ft. m

No.of

Pairs

UL NEC/C(UL) CEC

Type

Freq.(MHz)

Max.Atten.(dB/

100m)

Min.PSUMNEXT(dB)

Min.PSUMACR(dB/100m)

Min.PSUM

ELFEXT(dB/100m)

InputImped.

(Ω)

Min.RL(dB)

Nominal OD

StandardUnit Wt.

Lbs. kg Inch mm

PartNo.Description

Standard Lengths

Ft. m

No.of

Pairs

UL NEC/C(UL) CEC

Type

Freq.(MHz)

Max.Atten.(dB/

100m)

Min.PSUMNEXT(dB)

Min.PSUMACR(dB/100m)

Min.PSUM

ELFEXT(dB/100m)

InputImped.

(Ω)

Min.RL(dB)

62.353.347.344.339.935.432.327.8

60.349.240.836.128.218.410.31.0

60.848.740.836.730.924.820.814.7

100±15100±15100±15100±15100±15100±15100±15100±25

20.023.626.026.025.023.522.515.0

Industrial Data Solutions® — Industrial EthernetCategory 5e DataTuff® Twisted Pair Cables, 2-PairHeavy-Duty Sunlight and Oil-Resistant Jackets

Enhanced Cat 5e • 24 AWG Bonded-Pairs Solid BC • Rip Cord • See Color Code Chart

Non-Plenum • Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant Black PVC Jacket7923A NEC: 4 1000 304.8 28.0 12.7 .230 5.84

Compliant CMR, 2000 609.6 54.0 24.5CMX-

OutdoorCEC:

CMR FT4

Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C*RJ-45 Compatible • U.S. Patents 5,606,151 and 5,734,126 • Cable passes -40°C Cold Bend per UL1581Jacket sequentially marked at 2 ft. intervals. • Third party verified to TIA/EIA-568-B.2, Category 5e

Cat 5e • 24 AWG Solid BC • Twisted Pairs • Rip Cord • See Color Code Chart

Non-Plenum • Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant Black PVC Jacket7918A NEC: 4 1000 304.8 28.0 12.7 .230 5.84

CMR, 2000 609.6 52.0 23.6CMX-

OutdoorCEC:

CMR FT4

Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C*RJ-45 Compatible • Cable passes -40°C Cold Bend per UL1581Jacket sequentially marked at 2 ft. intervals. • Third party verified to TIA/EIA-568-B.2, Category 5e

ACR = Attenuation Crosstalk Ratio • BC = Bare Copper • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss*Subject to length de-rating.EtherNet/IP is a trademark of ControlNet International, Ltd. under license by Open DeviceNet Vendor Association, Inc.

Rip Cord

148

101625

31.2562.5100155200250350

2.04.05.76.48.1

10.311.616.821.727.732.036.444.3

65.356.351.850.347.344.342.938.435.332.530.829.327.2

63.352.346.143.939.134.131.321.617.14.73.0——

60.848.742.740.836.732.830.924.820.816.914.712.89.9

100±12100±12100±12100±12100±12100±15100±15100±15100±15100±18100±20100±20100±22

20.023.625.426.026.025.525.023.522.519.019.018.017.0

Category 5e DataTuff® Twisted Pair Cables, 4-PairHeavy-Duty Sunlight and Oil-Resistant Jackets

Rip Cord

14

1016

31.2562.5100200

2.04.16.58.2

11.717.022.032.4

62.353.347.344.339.935.432.327.8

60.349.240.836.128.218.410.31.0

60.848.740.836.730.924.820.814.7

100±15100±15100±15100±15100±15100±15100±15100±25

20.023.025.025.023.621.520.115.0

Color CodesPair No. Color Combination

1 White/Blue Stripe & Blue2 White/Orange Stripe & Orange

Pair No. Color Combination3 White/Green Stripe & Green4 White/Brown Stripe & Brown

14

1016

31.2562.5100200

2.04.16.58.2

11.717.022.032.4

Page 4: NP 211 BELDEN Cable - salesmanagementplus.com · This construction feature affixes the conductor ... CEC: CMR FT4 †2000 ft ... 4 1000 304.8 30.0 13.6 .242 6.15 Flexible CMR, 2000

Nominal OD

Enhanced Cat 5e • 24 AWG Bonded-Pairs Stranded TC (7x32) • See Color Code Chart

Non-Plenum • Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant Black PVC JacketStranded 7924A NEC: 4 1000 304.8 30.0 13.6 .242 6.15Flexible CMR, 2000 609.6 58.0 26.3

CMX-Outdoor

CEC:CMR FT4

Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C*RJ-45 Compatible • Cable passes -40°C Cold Bend per UL1581 • U.S. Patents 5,606,151; 5,734,126 and 5,763,823Jacket sequentially marked at 2 ft. intervals. • Third party verified to TIA/EIA-568-B.2, Category 5e

Enhanced Cat 5e • 24 AWG Stranded BC (7x32) • Twisted Pairs • See Color Code Chart

Non-Plenum • Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant Black PVC JacketStranded 7930A NEC: 4 1000 304.8 29.0 13.2 .240 6.09Flexible u CMR, 2000 609.6 56.0 25.4

CMX-Outdoor

CEC:CMR FT4

Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C*RJ-45 Compatible • Cable passes -25°C Cold Bend per UL1581 • Jacket sequentially marked at 2 ft. intervals. • Third party verified to TIA/EIA-568-B.2, Category 5e

Enhanced Cat 5e • 22 AWG Bonded-Pairs Solid BC • Rip Cord • See Color Code Chart

Non-Plenum • Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant Black PVC JacketPLTC 7922A NEC: 4 1000 304.8 46.3 21.0 .301 7.65

u PLTC, 2000 609.6 92.5 42.0CMR,CMX-

OutdoorCEC:

CMR FT4

Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C*Cable passes -25°C Cold Bend per UL1581 • Jacket sequentially marked at 2 ft. intervals.U.S. Patents 5,606,151 and 5,734,126 • Third party verified to TIA/EIA-568-B.2, Category 5e

Enhanced Cat 5e • 24 AWG Bonded-Pairs Solid BC • See Color Code Chart

FEP Insulation • Sunlight-, Oil- and Gas-resistant Black FEP Jacket7928A NEC: 4 1000 304.8 24.0 10.9 .187 4.75 (Same as 11700A below)

Compliant LimitedHigh & Low Temp CombustibleOil Res I & II FHC 25/50Gas Res CMP

CEC: CMP FT6

Operating and Installation Temperature: -70°C to +150°C* • U.S. Patents 5,606,151 and 5,734,126 • RJ-45 Compatible • Jacket sequentially marked at 2 ft. intervals. • Third party verified to TIA/EIA-568-B.2, Category 5e

Enhanced Cat 5e • 24 AWG Bonded-Pairs Solid BC • Rip Cord • See Color Code Chart

Non-Plenum • Polyolefin Insulation • PVC Inner Jacket • .035″ Industrial Grade Black or Gray PVC Outer Jacket11700A NEC: 4 1000 304.8 39.0 17.7 .285 7.24

Compliant CMR, 3000 914.4 117.0 53.2Upjacketed CMX- Nominal

Outdoor Core OD:CEC: .200 5.08

CMR FT4

Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C*Cable passes -40°C Cold Bend per UL1581RJ-45 Compatible • U.S. Patents 5,606,151 and 5,734,126 • Jacket sequentially marked at 2 ft. intervalsThird party verified to TIA/EIA-568-B.2, Category 5e • Outer jacket is sunlight- and oil-resistant.ACR = Attenuation Crosstalk Ratio • BC = Bare Copper • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • TC = Tinned Copper*Subject to length de-rating. EtherNet/IP is a trademark of ControlNet International, Ltd. under license by Open DeviceNet Vendor Association, Inc.

StandardUnit Wt.

Lbs. kg Inch mm

PartNo.Description

Standard Lengths

Ft. m

No.of

Pairs

UL NEC/C(UL) CEC

Type

Freq.(MHz)

Max.Atten.(dB/

100m)

Min.PSUMNEXT(dB)

Min.PSUMACR(dB/100m)

Min.PSUM

ELFEXT(dB/100m)

InputImped.

(Ω)

Min.RL(dB)

148

101625

31.2562.5100155200250350

2.44.86.87.79.7

12.413.920.226.033.238.443.753.2

65.356.351.850.347.344.342.938.435.332.530.829.327.2

62.951.545.042.637.531.929.018.39.2————

60.848.742.740.836.732.830.924.820.816.914.712.89.9

100±12100±12100±12100±12100±12100±15100±15100±15100±18100±18100±20100±20100±22

20.023.625.426.026.025.525.023.522.519.019.018.017.0

14

1016

31.2562.5100200

2.54.97.89.9

14.120.426.438.9

62.353.347.344.339.935.432.327.8

59.848.439.534.425.815.05.9—

60.848.740.836.730.924.820.814.7

100±15100±15100±15100±15100±15100±15100±15100±25

20.023.025.025.023.621.520.115.0

148

101625

31.2562.5100155200250350

2.04.05.76.48.1

10.311.616.821.727.732.036.444.3

65.356.351.850.347.344.342.938.435.332.530.829.327.2

63.352.346.143.939.134.131.321.617.14.73.0——

60.848.742.740.836.732.830.924.820.816.914.712.89.9

100±12100±12100±12100±12100±12100±15100±15100±15100±15100±18100±20100±20100±22

20.023.024.525.025.024.323.621.520.119.019.018.017.0

Color CodesPair No. Color Combination

1 White/Blue Stripe & Blue2 White/Orange Stripe & Orange

Pair No. Color Combination3 White/Green Stripe & Green4 White/Brown Stripe & Brown

Rip Cord

148

101625

31.2562.5100155200250350

2.04.05.76.48.1

10.311.616.821.727.732.036.444.3

65.356.351.850.347.344.342.938.435.332.530.829.327.2

63.352.346.143.939.134.131.321.617.14.73.0——

60.848.742.740.836.732.830.924.820.816.914.712.89.9

100±12100±12100±12100±12100±12100±15100±15100±15100±15100±18100±20100±20100±22

20.023.625.426.026.025.525.023.522.519.019.018.017.0

Rip Cord

Page 5: NP 211 BELDEN Cable - salesmanagementplus.com · This construction feature affixes the conductor ... CEC: CMR FT4 †2000 ft ... 4 1000 304.8 30.0 13.6 .242 6.15 Flexible CMR, 2000

Nominal OD

Enhanced Cat 5e • 24 AWG Bonded-Pairs Solid BC • Rip Cord • See Color Code Chart

Non-Plenum • Polyolefin Insulation • PVC Inner Jacket • .035″ Industrial Grade Black or Blue PVC Outer JacketOil Res I & II 11700A2 NEC: 4 1000 304.8 42.0 19.1 .285 7.24Upjacketed u CMR 2000† 609.6 86.0 39.1

CEC: NominalCMR FT4 Core OD:

.200 5.08

†2000 ft. put-up available in Black only.Installation Temperature: -10°C to +75°C; Operating Temperature: -25°C to +75°C*RJ-45 Compatible • U.S. Patents 5,606,151 and 5,734,126 • Jacket sequentially marked at 2 ft. intervalsThird party verified to TIA/EIA-568-B.2, Category 5e • Outer jacket is also sunlight resistant.

Enhanced Cat 5e • 24 AWG Bonded-Pairs Solid BC • Polyester Wrap • Rip Cord • See Color Code Chart

Non-Plenum • Polyolefin Insulation • PVC Inner Jacket • .045″ Industrial Grade Black or Gray PVC Outer JacketInterlocked 121700A NEC: 4 1000 304.8 159.0 72.0 .530 13.46AL Armor CM 3000 914.4 459.0 210.6

CEC: NominalHL Core OD:

CMG FT4 .200 5.08

Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C*RJ-45 Compatible • Cable passes -40°C Cold Bend per UL1581U.S. Patents 5,606,151 and 5,734,126 • Jacket sequentially marked at 1 meter intervals.Third party verified to TIA/EIA-568-B.2, Category 5e • Outer jacket is sunlight- and oil-resistant.

Cat 5e • 24 AWG Bonded-Pairs Solid BC • Overall Beldfoil® Shield • 24 AWG Stranded TC Drain Wire • See Color Code Chart

Non-Plenum • Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant Black PVC JacketShielded 7929A NEC: 4 1000 304.8 37.0 16.8 .265 6.73

CMR, 2000 609.6 72.0 32.7CMX-

OutdoorCEC:

CMR FT4

Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C*RJ-45 Compatible • Cable passes -40°C Cold Bend per UL1581 • U.S. Patents 5,606,151 and 5,734,126Shield is bonded to jacket inner wall for electrical stability. • Jacket sequentially marked at 2 ft. intervals. • Third party verified to TIA/EIA-568-B.2, Category 5e

Cat 5e • 24 AWG Solid BC • Twisted Pairs • Overall Beldfoil Shield • 24 AWG Stranded TC Drain Wire • See Color Code Chart

Non-Plenum • Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant Black PVC JacketShielded 7919A NEC: 4 1000 304.8 35.0 15.9 .265 6.73

CMR, 2000 609.6 68.0 30.9CMX-

OutdoorCEC:

CMR FT4Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C* • Cable passes -40°C Cold Bend per UL1581RJ-45 Compatible • Shield is bonded to jacket inner wall for electrical stability. • Jacket sequentially marked at 2 ft. intervals. • Third party verified to TIA/EIA-568-B.2, Category 5e

Cat 5e • 24 AWG Bonded-Pairs Solid BC • Overall Beldfoil + 70% TC Braid • 24 AWG Solid Spiral Drain Wire • See Color Code Chart

Non-Plenum • Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant Black PVC Jacket7921A NEC: 4 1000 304.8 55.0 24.9 .330 8.38

Compliant CMR, 2000 609.6 100.0 48.1Heavy-shielded CMX-

OutdoorCEC:

CMR FT4

Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C* • Cable passes -40°C Cold Bend per UL1581U.S. Patents 5,606,151 and 5,734,126 • Jacket sequentially marked at 2 ft. intervals. • Third party verified to TIA/EIA-568-B.2, Category 5eACR = Attenuation Crosstalk Ratio • AL = Aluminum • BC = Bare Copper • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • TC = Tinned Copper*Subject to length de-rating.EtherNet/IP is a trademark of ControlNet International, Ltd. under license by Open DeviceNet Vendor Association, Inc.

StandardUnit Wt.

Lbs. kg Inch mm

PartNo.Description

Standard Lengths

Ft. m

No.of

Pairs

UL NEC/C(UL) CEC

Type

Freq.(MHz)

Max.Atten.(dB/

100m)

Min.PSUMNEXT(dB)

Min.PSUMACR(dB/100m)

Min.PSUM

ELFEXT(dB/100m)

InputImped.

(Ω)

Min.RL(dB)

Rip Cord

148

101625

31.2562.5100155200250350

2.04.05.76.48.1

10.311.616.821.727.732.036.444.3

65.356.351.850.347.344.342.938.435.332.530.829.327.2

63.352.346.143.939.134.131.321.617.14.73.0——

60.848.742.740.836.732.830.924.820.816.914.712.89.9

100±12100±12100±12100±12100±12100±15100±15100±15100±15100±18100±20100±20100±22

20.023.024.525.025.024.323.621.520.119.019.018.017.0

Rip Cord

14

1016

31.2562.5100200

2.04.16.58.2

11.717.022.032.4

62.353.347.344.339.935.432.327.8

60.349.240.836.128.218.410.31.0

60.848.740.836.730.924.820.814.7

100±15100±15100±15100±15100±15100±15100±15100±25

20.023.025.025.023.621.520.115.0

Color CodesPair No. Color Combination

1 White/Blue Stripe & Blue2 White/Orange Stripe & Orange

Pair No. Color Combination3 White/Green Stripe & Green4 White/Brown Stripe & Brown

14

1016

31.2562.5100

2.04.16.58.2

11.717.022.0

62.353.347.344.339.935.432.3

60.349.240.836.128.218.410.3

60.848.740.836.730.924.820.8

100±15100±15100±15100±15100±15100±15100±15

20.023.025.025.023.621.520.1

14

1016

31.2562.5100

2.04.16.58.2

11.717.022.0

62.353.347.344.339.935.432.3

60.349.240.836.128.218.410.3

60.848.740.836.730.924.820.8

100±15100±15100±15100±15100±15100±15100±15

20.023.626.026.025.023.522.5

148

101625

31.2562.5100155200250350

2.04.05.76.48.1

10.311.616.821.727.732.036.444.3

65.356.351.850.347.344.342.938.435.332.530.829.327.2

63.352.346.143.939.134.131.321.617.14.73.0——

60.848.742.740.836.732.830.924.820.816.914.712.89.9

100±12100±12100±12100±12100±12100±15100±15100±15100±15100±18100±20100±20100±22

20.023.024.525.025.024.323.621.520.119.019.018.017.0

Page 6: NP 211 BELDEN Cable - salesmanagementplus.com · This construction feature affixes the conductor ... CEC: CMR FT4 †2000 ft ... 4 1000 304.8 30.0 13.6 .242 6.15 Flexible CMR, 2000

Enhanced Cat 6 • 23 AWG Bonded-Pairs Solid BC • Patented E-Spline Center Member • Rip Cord • See Color Code Chart

Non-Plenum • Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant Black PVC Jacket7927A NEC: 4 1000 304.8 44.0 20.0 .251 6.38

CMR 2000 609.6 88.0 39.9 x xCEC: .339 8.61

CMR FT4

Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C*RJ-45 Compatible • Cable passes -40°C Cold Bend per UL1581U.S. Patents 5,606,151; 5,734,126; 5,789,711 and 6,297,454-B1Jacket sequentially marked at 2 ft. intervals. • Third party verified to TIA/EIA-568-B.2-1, Category 6**PSUM ACR >0 is guaranteed to 460 MHz.

Cat 6 • 23 AWG Bonded-Pairs Solid BC • See Color Code Chart

FEP Insulation • Sunlight-, Oil- and Gas-resistant Black FEP JacketHigh & Low Temp 7931A NEC: 4 1000 304.8 35.0 15.9 .214 5.44Oil Res I & II LimitedGas Res Combustible

FHC 25/50CMPCEC:

CMP FT6Operating Temperature: -70°C to +150°C*RJ-45 Compatible • U.S. Patents 5,606,151 and 5,734,126Jacket sequentially marked at 2 ft. intervals. • Third party verified to TIA/EIA-568-B.2-1, Category 6

Enhanced Cat 6 • 23 AWG Bonded-Pairs Solid BC • Rip Cord • See Color Code ChartNon-Plenum • Polyolefin Insulation • PVC Inner Jacket • .035″ Industrial Grade Black or Gray PVC Outer Jacket

Upjacketed 11872A NEC: 4 1000 304.8 66.0 30.0 .475 12.07CM x xCEC: .265 6.73CM FT1 Nominal

Core OD:.365 9.27

Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C* x xCable passes -25°C Cold Bend per UL1581 • U.S. Patents 5,606,151, 5,734,126 and 5,821,467 .165 4.19RJ-45 Compatible • Jacket sequentially marked at 2 ft. intervals. • Verified to TIA/EIA-568-B.2-1, Category 6**Value provided for information only.

Enhanced Cat 6 • 23 AWG Bonded-Pairs Solid BC • Polyester Wrap • Rip Cord • See Color Code ChartNon-Plenum • Polyolefin Insulation • PVC Inner Jacket • .055″ Industrial Grade Black or Gray PVC Outer Jacket

Interlocked 121872A NEC: 4 1000 304.8 222.0 100.6 .684 17.37 (Same as 11872A above)AL Armor CM

CEC: NominalHL Core OD:

CMG FT4 .365 9.27x x

.165 4.19Installation Temperature: -25°C to +75°C; Operating Temperature: -40°C to +75°C*RJ-45 Compatible • Cable passes -40°C Cold Bend per UL1581U.S. Patents 5,606,151, 5,734,126 and 5,821,467 • Jacket sequentially marked at 1 meter intervals. • Verified to TIA/EIA-568-B.2-1, Category 6

ACR = Attenuation Crosstalk Ratio • AL = Aluminum • BC = Bare Copper • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss*Subject to length de-rating.EtherNet/IP is a trademark of ControlNet International, Ltd. under license by Open DeviceNet Vendor Association, Inc.

Nominal OD

StandardUnit Wt.

Lbs. kg Inch mm

PartNo.Description

Standard Lengths

Ft. m

No.of

Pairs

UL NEC/C(UL) CEC

Type

Freq.(MHz)

Max.Atten.(dB/

100m)

Min.PSUMNEXT(dB)

Min.PSUMACR(dB/100m)

Min.PSUM

ELFEXT(dB/100m)

InputImped.

(Ω)

Min.RL(dB)

Industrial Data Solutions® — Industrial EthernetCategory 6 DataTuff® Twisted Pair Cables, 4-PairHeavy-Duty Sunlight and Oil-Resistant Jackets

Color CodesPair No. Color Combination

1 White/Blue Stripe & Blue2 White/Orange Stripe & Orange

Pair No. Color Combination3 White/Green Stripe & Green4 White/Brown Stripe & Brown

Rip Cord

110

31.2562.5100155200250350400500550600

1.95.7

10.214.718.923.927.531.237.740.646.248.851.4

80.365.357.953.450.347.545.844.340.239.337.837.236.6

78.559.647.738.731.423.518.313.24.50.6

>0.0 **——

70.850.840.934.930.827.024.822.819.918.816.816.015.2

100±12100±12100±15100±15100±15100±15100±15100±20100±22100±22100±22100±22100±22

20.025.025.025.025.022.821.720.519.819.518.418.017.6

11020

31.2562.5100200250

2.06.08.5

10.715.419.829.032.8

72.357.352.849.945.442.337.836.3

70.351.344.339.230.022.58.83.5

64.844.838.734.928.824.818.716.8

100±15100±15100±15100±15100±15100±15100±22100±32

20.025.025.023.621.520.118.017.3

Rip Cord

Rip Cord

14

1016

31.2562.5100155200310350400**500**

1.93.75.97.5

10.615.419.825.129.037.139.843.049.0

72.363.357.354.349.945.442.339.537.934.934.233.331.8

705951463930251410————

64.852.744.840.734.928.824.820.918.714.913.912.710.8

100±12100±12100±12100±12100±15100±15100±15100±15100±15100±20100±22100±32100±32

20.023.025.025.023.621.521.021.021.018.017.014.014.0

Page 7: NP 211 BELDEN Cable - salesmanagementplus.com · This construction feature affixes the conductor ... CEC: CMR FT4 †2000 ft ... 4 1000 304.8 30.0 13.6 .242 6.15 Flexible CMR, 2000

Environmental Issues Industrial Grade Jacket

OilResistance

UV Sunlight

ResistanceGasoline

ResistanceHi/LoTemp Heavy ArmoredUpjacketCMX/

Outdoor

DataTuff® Industrial Ethernet Cable Selection Guide

This chart is meant to help the user in proper cable selection. Refer to cable specifications for details. See www.belden.com for fiber optic cable recommendations and technical data sheets.

Conductor

Solid Stranded**

Part No. Unshielded Shielded*

Shielding Installation

Installation Stress

Resistance†Pull

Tension

u

uu

u

EtherNet/IP is a trademark of ControlNet International, Ltd. under license by Open DeviceNet Vendor Association, Inc.

Category 5e • 2-Pair Cable7933A 20

Category 5e • 4-Pair Cable7923A 40

7918A 35

7924A 40

7930A 25

7922A 40 PLTC

7928A 40

11700A 40

11700A2 40 Oil Res I & II

121700A 40

7929A 35

7919A 25

7921A 75

Category 6 • 4-Pair Cable7927A 45

7931A 40

11872A 45

121872A 45

* Shielded products are recommended for high-noise environments.** Stranded products are recommended where more flexibility is needed.† Products with Bonded-Pair technology provide Installable Performance® advantages — refer to Belden’s Bonded-Pair Cable Bulletin #BP02.

Page 8: NP 211 BELDEN Cable - salesmanagementplus.com · This construction feature affixes the conductor ... CEC: CMR FT4 †2000 ft ... 4 1000 304.8 30.0 13.6 .242 6.15 Flexible CMR, 2000

Product Description

The TrayOptic series cables are designed for indoor/outdoorindustrial applications. All TrayOptic cables have been upgradedwith a water-blocking agent. The TrayOptic series carry the IEEE383 flame approval. All TrayOptic series products utilize the LCF™

(Laser Certified Fiber) to handle tomorrow’s Gigabit Ethernet lightsources and expanded bandwidth requirements. TrayOptic cablesare also available with 50 micron or single-mode fiber upon request.

Product Specifications

Fiber Counts* 2 through 24

Fiber Size 62.5µm

Buffer Sizes≤ 6 Fibers 2.0mm> 6 Fibers 2.5mm

Jacket Materials PVC or CPE

Flame Test Passes IEEE 383 and UL 1581 Vertical Tray Flame Tests

UL Listing NEC/CEC2 to 12 Fibers OFNR FT418 to 24 Fibers OFN FT1

Strength Members Dielectric Central Member/Fiberglass Yarn

Temperature Range -40 to +75°C

Crush Resistance2 to 6 Fibers 750 lbs./in. min.8 to 24 Fibers 500 lbs./in. min.

Impact Resistance 3.3 ft.-lbs./25 impacts min.

Flexing 25 cycles, 12 lbs., 20 x OD radius min.

Twist/Bend 25 cycles, 12 lbs., 20 x OD radius min.

Minimum Bend RadiusInstallation 20 x ODLong Term 10 x OD

Maximum Recommended Load (Lbs.)Installation 600Long Term 180

*1- through 6-fiber cables are single fiber per tube.

Fiber Specifications

62.5µm

Max. Attenuation (dB/km @850/1300nm) 3.5/1.0

Min. Bandwidth (MHz-km @850/1300nm) 220/600

Numerical Aperture 0.275

TrayOptic® Heavy-Duty, All Dielectric Fiber Optic Cable Loose Tube — Indoor/Outdoor Riser & Tray

Riser (NEC/CEC OFNR FT4)

62.5/125/245 Micron (Core/Clad/Coating)

I100255 PVC 2 .469 11.91 93 138I100266 CPE 2 .469 11.91 89 132I100455 PVC 4 .469 11.91 91 135I100466 CPE 4 .469 11.91 80 119I100655 PVC 6 .469 11.91 89 120I100666 CPE 6 .469 11.91 85 126I400855 PVC 8 .572 14.53 140 190I400866 CPE 8 .572 14.53 132 196I601055 PVC 10 .572 14.53 135 183uI601255 PVC 12 .572 14.53 135 183I601266 CPE 12 .572 14.53 139 207

Tray (NEC/CEC OFN FT1)

62.5/125/245 Micron (Core/Clad/Coating)

I601855 PVC 18 .572 14.53 133 180I601866 CPE 18 .572 14.53 136 202I602455 PVC 24 .572 14.53 133 180I602466 CPE 24 .572 14.53 137 204

No. of Fibers

PartNo.

JacketMaterial Inch mm

Outer Diameter

Lbs./1000′′ kg/km

Weight

OpticalFibers

OrangeOuter Jacket

Binder

FiberglassStrengthMember

DielectricCentral Strength

Member

Water-blockingAgent

InnerJacket

Gel FilledBuffer Tube

For More Information: www.belden.com

Belden CDT Electronics Division Technical Support 1-800-BELDEN-1 or 1-800-BELDEN-3

©Copyright 2004, Belden CDT Inc.NP211 replaces NP197