8
NUFLO Scanner 2000 microEFM Well Testing Solution

Upload: others

Post on 12-Nov-2021

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NUFLO Scanner 2000 microEFM Well Testing Solution

1

NUFLO Scanner 2000 microEFMWell Testing Solution

Page 2: NUFLO Scanner 2000 microEFM Well Testing Solution

2

• API21.1compliant

• Non-volatilememory

• Adjustablelogginginterval Fivesecondsto12hours

Packaging

• Easy-to-readLCD

• Userfriendlykeypadoperations

• Multipleenclosureandmountingoptions

Communications

• TwoRS-485communicationports

• USBlocalcommunicationsoption

• Modbus®protocol(RTUandENRON)

• Twowirecommunication

Calibration

• 1to12calibrationpointsavailableforallinputs

Inputs/Outputs

• Accurate,stableandrepeatableinputreadingsusinganintegralMVT

• Baseunit: Processtemperatureinput Turbinemeterinput Digitaloutput

(volumetricpulseoutputoralarm)

• Withexpansionboard: Secondturbinemeterinput Pulseinput Twoanaloginputs Analogoutput

FeaturesPower

• Low-poweroperation

• Fullyautonomousoperationvialithiumbatterypack(1-yeartypical)forstand-aloneinstallations

• Whendeviceisexternallypowered;lithiumbatterypackprovidesbackuppowersupplyanddataisprotectedforupto10years

Performance

• Industrystandardcalculation AGA-3 AGA-7 ISO5167 ASMEMFC-12M

(AveragingPitotTube) AGA-8(Detail&Gross) IF-97(Steam) API-2540(Liquid)

• FieldrecognizedDPConemeteralgorithm

• Archivesupto16user-selectableparameters

• Generouslogcapacity: 768dailyrecords 2304intervalrecords

(6392withexpansionboardoption) 1152event/alarmrecords

• Fastdatatransfer Fullarchivedownloadinapproximately

threeminuteswithmainboardonly Sixminuteswithexpansionboard

option

The convenienceMaking Measurement

Easy... -To Afford -To Operate -To Integrate -To Optimize

Cameron’s NUFLO™ Scanner® 2000

microEFM packs the gas, liquid and

ancillary measurement capabilities,

traditionally found in large flow

computers, into a compact, low-

power instrument that operates

economically as a stand-alone

chart recorder replacement, flow

computer, data logger and totalizer

making it the ideal product for test

separator measurement.

By gathering all liquid and gas

flow rates, wellhead pressure and

temperature, casing pressure,

separator pressure and temperature

into a single common platform, all

the data is immediately available

to view, log or trend via industry

standard well testing software

packages. A reduction between 15%

to 20% of total transmitters and

vastly simplified wiring makes rig up

of portable test separators very quick

and simple. All the transmitters are

on a single RS485 loop.

Simplicity and ease of use are integral to the design of the Scanner 2000. All parameters can be easily configured using a PC or laptop and the ModWorX™ Pro software – which is included with every Scanner 2000.

of a low-power, compact flow computer

2

Page 3: NUFLO Scanner 2000 microEFM Well Testing Solution

The versatility

Totalizer /TFMMountforLiquidMeasurment

Turbine Meter Mount

Cameron’sEZ-INtubinemeteristheindustry

standardforwelltesting.

•Rugged,lowcostdesign

•ReducedweightoverconventionalTFMs

•Easytocalibrateinthefield

•Copeswithsandandwatermixture

Data Logging

Deliverscasing,tubing,wellhead,separatorpressures

andtemperaturesontothesameRS485loop.

•Logsdailyandintervalrecordsofupto16

user-selectableparametersandstoresthedatain

nonvolatilememoryforupto10years

•Explosion-proofenclosure

•External1to5VDCor4-20mAtransmittersorRTD

DP Cone Meter (or orifice fitting)

ThedirectmountedScanner2000/DPConesystemand

reducesriguptime,leakpathsandincreasesaccuracy.

•Widerangeofflow

•ReducedpersonnelexposuretoH2S/HPgas

•Reducedweight

•Noplatestochange

•Lessinstallationlengthfromdualchamberorificefittings

•Highlywearresistant

PID Control

•Levelcontrolofseparator

•Automaticswitchingbetween

highandlowflowmeters

•Separatorpressurecontrol

• Gasliftcontrol

• Twoanaloginputsfor

externaldevices

Simultaneous Gas/Liquid Measurement

Inexpensiveexpansionboardoptiondelivers:

•Increaseddevicememory

•Secondturbinemeterinput

•PulseInput

•Twoanaloginputs

3

of a low-power, compact flow computer of a common platform

Page 4: NUFLO Scanner 2000 microEFM Well Testing Solution

4

The benefits of making it easy

TubingP & T

Down-streamP & T

ChokeManifold

CasingPress

Customer’s PC

Surge Tank

Gas ConeMeter

Gas ConeMeter(s)

Separator

PilotReliefValve

Free WaterTFM(s)

EmulsionTFM(s)

Wellhead

Fardux Fekete

Expro EdgeX

Data AcquisitionSystem

to afford to operate and integrate to optimize

Reduces the total numberof transmitters required

Simplified wiring– only two pairs requiredfor the entire package

Free interface software(ModWorX Pro)

Operates for up to12 months on aninternal battery

Simplified training– one platform forall transmitters

Reduced installation costs

Simplified sparesrequirements, eachscanner shares the samebasic components

No need for additionalanalog to digital interfaces

Integrating the Scanner 2000 Into Existing Data Aquisition SystemsCameronactivelypursuestechnicalandstrategicrelationshipswithkeywelltestingdataaquisitionsolutionsproviderstoensurethattheScanner2000operatestransparentlywiththeirsoftware.Wehaveworkedalongsidevariousproviderstoenabletheirsoftwaretolog,trendanddisplayfast(onesecond)updatingdisplaysfromnumerousScannersinonesystem.Two-waycommunicationallowsforspecificparameters,suchasplatesizes,K-factorsandgasSGtobewrittendirectlyintothescannerfromwithintheirsoftwareinthecontrolcabin.

Page 5: NUFLO Scanner 2000 microEFM Well Testing Solution

5

TubingP & T

Down-streamP & T

ChokeManifold

CasingPress

Customer’s PC

Surge Tank

Gas ConeMeter

Gas ConeMeter(s)

Separator

PilotReliefValve

Free WaterTFM(s)

EmulsionTFM(s)

Wellhead

Fardux Fekete

Expro EdgeX

Data AcquisitionSystem

to afford to operate and integrate to optimize

Transitioning Solutions(frommechanicaltoelectronicmeasurement)•Lowproducingwells•Unconventionalgas•Coalbedmethane•Shale•Airmeasurement•Welltesting/Three-phaseseparatormeasurement•Chemicalfracturing•Rotarymetermeasurement•LACTmeasurement

Expanding or ModernizingExisting Measurement Systems•Checkmeter•Custodytransfer/measurementCanadaapproval

•Gasstorage•Three-phaseseparator•Saltwaterdisposal

Application Solutions•Singleflowrun•Multiflowrun•Steam•Compensatedliquid

Single Source forMeters and Electronics:Easy Product Packages•Scanner2000andNUFLOOrificeMeters

•Scanner2000andNUFLODPConeMeters

•Scanner2000andNUFLOTurbineMeters

•Scanner2000andBARTON®TurbineMeters

Integrating the Scanner 2000 Into Existing Data Aquisition SystemsCameronactivelypursuestechnicalandstrategicrelationshipswithkeywelltestingdataaquisitionsolutionsproviderstoensurethattheScanner2000operatestransparentlywiththeirsoftware.Wehaveworkedalongsidevariousproviderstoenabletheirsoftwaretolog,trendanddisplayfast(onesecond)updatingdisplaysfromnumerousScannersinonesystem.Two-waycommunicationallowsforspecificparameters,suchasplatesizes,K-factorsandgasSGtobewrittendirectlyintothescannerfromwithintheirsoftwareinthecontrolcabin.

Page 6: NUFLO Scanner 2000 microEFM Well Testing Solution

6

z

EZ-IN Series BF Flow Meter Specifications

Flow MeterSize

Linear Flow Ranges (based on Water)Nominal

Calibration FactorMax. Output

FrequencyΔρ at Max.

in. gal/min m3/h B/D pulses x 1000/m3 pulses/gallonpulses/sec

psi (kPa)

3/8 0.3 to 3 0.068 to 0.68 10 to 100 22,000 (5812) 1100 4 (28)

1/2 0.75 to 7.5 0.17 to 1.70 25 to 250 14,500 ( 3830) 1815 12 (83)

3/4 2 to 15 0.45 to 3.41 68 to 515 2950 (780) 740 18 (124)

7/8 3 to 30 0.68 to 6.81 100 to 1000 2350 (621) 1175 20 (138)

1 5 to 50 1.14 to 11.36 170 to 1700 900 (28) 750 20 (138)

1 1/2 x 2 15 to 180 3.41 to 40.88 515 to 6000 325 (86) 975 16 (110)

2 40 to 400 9.09 to 90.85 1300 to 13,000 55 ( 14.5) 365 22 (152)

3 80 to 800 18.17 to 181.7 2,742 to 27,428 57 (15.2) 760 16 (110.4)

4 100 to 1200 22.71 to 272.55 3400 to 41,000 30 (7.9) 600 10 (69)

6 250 to 2500 56.78 to 567.82 8600 to 86,000 7 (1.8) 2900 10 (69)

8 350 to 3500 79.49 to 7944.94 12,000 to 120,000 3 (0.8) 175 6 (41)

Note:Thelinearflowrangeofliquidswithnon-lubricatingcharacteristicsislimitedtotheupper60%oftheupperrating.Ifusingtheflowmeterwithliquidshavingviscositiesmorethanfivecentistokes,consultthefactoryforengineeringassistance.

Bearing Support

Flow Meter Body

Socket Head Capscrews

Rotor

Bearing Support

Socket Head Screws

Rotorisaonepiececasting,withnoweldsorjointstocauseweakspots.Theshaftcanbebrazedtotherotor,soitcannotbeknockedloose.

Bearingsupportsareshieldedfromtheflowinarecessedboreandareoverlappedbytheflange.

Capscrewsarethereonlyforbearingsupportretentionduringtransport/installation.Bearingsupportcannotbeknockedloosebyfluidhammerorbyvibrationintheline.

Magnetic Pickup

Series BF Flow Meters

EZ-IN Liquid Meters

Page 7: NUFLO Scanner 2000 microEFM Well Testing Solution

7

z

Cone Meter

Wide RangeabilityCameron’sNUFLOConeMeterisdesignedtooperateoverlargeturndownswhichallowsdifferentialpressurestobemeasureddownto<1”watercolumn.Theconemeteralsogeneratesalownoisedifferentialpressuresignalatthecenterandbackofthecone.

High Performance CharacteristicsTheNUFLOConeMeterachievesaccuraciesofupto±0.5%ofreading(Reynoldsnumberandfluiddependent)withanominalrepeatabilityof0.1%undermanyconditionsandmodesofoperation.Themetercanoperatewithturndownsnominallyupto10to1.Thesespecificationsmeetcustodytransferperformancerequirementsfornaturalgastransmissionmeasurementswithsizesto>36”.(ContactCameronforexactrangeabilityperprocessfluid.)

Technical Flexibility TheNUFLOConeMetercanbemanufacturedindiametersfrom1”to48”withflangesrangingfromClass150to1500inaccordancewithASMEB31.3.Thissizingflexibility,plustheavailabilityofspecialmaterials(duplexstainlesssteelandhastelloy)offersanewsolutionforspecialtyfluidmeteringrequirements.

Space Savings and Weight Reduction Differentialpressuresystemsusuallyrequirelongupstreamanddownstreamlengthswhichaddhighoverallcosttomostmeteringinstallations.TheNUFLOConeMeterhastheabilitytore-distributeandchangethevelocityprofileupstreamofitscone.Thisflowconditioningallowsfortheuseofashortermeterrunwhichinturnreducesinstallationandsetupcosts.Thisisespeciallysignificantinthewelltestingenvironmentwherespaceandweightissuesarerelevantandwhererealestateisatapremium.

Low Cost of Ownership TheNUFLOConeMeterhasnomovingpartsnordoesitrequirethereplacementofprimarysparepartsfortheoperationallifeoftheunit.ThemeterisconstructedfromhighgradetraceablematerialsandbothhighqualityweldingandNDTtechniquesarestrictlyappliedthroughoutinthemanufacturingprocess.

Minimumwearoccursatthebetaedgeoftheconebecausethisedgeisdownstreamoftheflowwhichhelpstomaintainaconstantstablegeometrythroughthemeter’soperatinglife.

• Wideturndown(10:1)

• Reducedcapitalandmaintenancecosts

• Longtermstabilityandaccuracy

• Lowerpressurelossforsimilarflow

• Reducedinstallationspace

• Stable,lownoisemeasurement

• Abilitytocopewithwetgas

• Selfconditioningeffect

• Lighterandeasiertoinstallandtransport

• Nochangingplates–humanerror,H2S/HPsafety,removingdamagedplate

• Simplifiedtraining

• Quickerdelivery

• Digitalinformation/dataloggingavailablefromtheScanner2000

Repeatable

Accurate

Ideal for tough to measure applications

Compact space saving design

Low cost of ownership

NUFLO DP Cone Meter shown with the NUFLO Scanner 2000 microEFM

benefits over an orifice plate

Page 8: NUFLO Scanner 2000 microEFM Well Testing Solution

8 ©2013Cameron|NUFLOisaregisteredtrademarkofCameron.|SWP2M,02/13|AD00586M

HEALT

H S

AFE

TY S

ECURITY AND ENVIRONM

ENTAL EX

CELLENCE

CAMERON

NORTH AND SOUTH AMERICA

14450JFKBlvd.

Houston,TX77032

USA

Tel12815829500

[email protected]

IndustrialProducts

4040CapitolAvenue

CityofIndustry,CA90601

Tel:5622228440

E-mail:[email protected]

EUROPE, AFRICA, CASPIAN AND RUSSIA

3SteyningWay

SouthernCrossTradingEstate

BognorRegis

WestSussexPO229TT

England,UK

Tel441243826741

[email protected]

MIDDLE EAST

Level9,AlJaziraClubTowerA

P.O.Box47280,MuroorRoad

AbuDhabi

UnitedArabEmirates

Tel97125968400

[email protected]

ASIA PACIFIC

Suite16.02MenaraAmFirst

No.1Jalan19/3

46300PetalingJaya

SelangorDarulEhsan

Malaysia

Tel60379540145

[email protected]

HSSE Policy StatementAt Cameron, we are committed ethically, financially and personally to a working environment where no one gets hurt and nothing gets harmed.

©2013Cameron|NUFLOandModWorXaretrademarksofCameron.BARTONandScannerareregisteredtrademarksofCameron.|SWP2M,04/13AD00586M