number d x ac transit brt northern layover breakroom · oakland, ca project # p2004 drawing index...

9
PROJECT SITE AC TRANSIT BRT NORTHERN LAYOVER BREAKROOM 2103 SAN PABLO AVENUE OAKLAND, CA PROJECT # P2004 DRAWING INDEX SCOPE OF PROJECT ABBREVIATIONS APPLICABLE CODES IMPORTANT NOTICE U L U N D E R G R O C A L A L E R T R V I C E N 1 8 1 D S E SITE INFORMATION VICINITY MAP DPW, CE 12/12/2019 4:37 PM 19R-118 C0 - C1.dwg REFERENCES: 7770 PARDEE LANE, SUITE 100 OAKLAND, CA 94621 CHOW ENGINEERING, INC. Phone: (510) 636-8500 Fax: (510) 636-8544 [email protected] http://choweng.com 19R-118 C0 - C1 Attachment 2- Drawings

Upload: others

Post on 05-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NUMBER D X AC TRANSIT BRT NORTHERN LAYOVER BREAKROOM · oakland, ca project # p2004 drawing index scope of project abbreviations applicable codes important notice u l u n d e r g

PROJECT SITE

AC TRANSIT BRT NORTHERN LAYOVER BREAKROOM

2103 SAN PABLO AVENUEOAKLAND, CA

PROJECT # P2004

DRAWING INDEX

SCOPE OF PROJECT

ABBREVIATIONS APPLICABLE CODES

IMPORTANT NOTICE

U

L

UN

DER

GR

O

C A L

AL ERT

RVICE

N

18 1

D S E

SITE INFORMATION

VICINITY MAP

DPW

, CE

12/1

2/20

19 4

:37

PM19

R-1

18 C

0 - C

1.dw

g

REFERENCES: 7770 PARDEE LANE, SUITE 100OAKLAND, CA 94621

CHOW ENGINEERING, INC.

Phone: (510) 636-8500 Fax: (510) 636-8544

[email protected]://choweng.com 19R-118 C0 - C1

Attachment 2- Drawings

AutoCAD SHX Text
THESE PLANS ARE FOR RENOVATION OF AN EXISTING TENANT SPACE FOR A NEW AC TRANSIT BREAKROOM AT THE GREYHOUND BUS TERMINAL. THE WORK INCLUDES REMOVAL OF RESTROOM FIXTURES, WALLS, LIGHTING FIXTURES, FLOOR DRAINS, AND MISCELLANEOUS ITEMS, AND INSTALLING NEW RESTROOM FIXTURES, FLOORING, WALL COVERINGS, CABINETS AND SINK, APPLIANCES AND FURNITURE, AND INCLUDES PLUMBING, ELECTRICAL, COMMUNICATIONS SYSTEMS.
AutoCAD SHX Text
SHEET DWG NO.SHEET TITLE DWG NO.SHEET TITLE SHEET TITLE 1 C0-TITLE SHEET 2 C1-GENERAL NOTES 3C2-DEMOLITION PLAN C2-DEMOLITION PLAN 4 C3-FLOOR PLAN 5C4-INTERIOR ELEVATIONS C4-INTERIOR ELEVATIONS 6C5-DETAILS C5-DETAILS 7M1-MECHANICAL FLOOR PLAN M1-MECHANICAL FLOOR PLAN 8M2-MECHNICAL ROOF PLAN M2-MECHNICAL ROOF PLAN 9E1-ELECTRICAL PLAN E1-ELECTRICAL PLAN
AutoCAD SHX Text
2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA PLUMBING CODE 2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA ENERGY CODE 2019 CALIFORNIA GREEN BUILDING CODE
AutoCAD SHX Text
AB AGGREGATE BASE AGGREGATE BASE ANCHANCHOR ANCHOR APPROXAPPROXIMATELY APPROXIMATELY BGSBELOW GROUND SURFACE BELOW GROUND SURFACE BLDGBUILDING BUILDING BGBELOW GRADE BELOW GRADE CBCATCH BASIN CATCH BASIN CBCCALIFORNIA BUILDING CODE CALIFORNIA BUILDING CODE CLRCLEAR CLEAR CONCCONCRETE CONCRETE CJCONSTRUCTION JOINT CONSTRUCTION JOINT DI DRAIN INLET DRAIN INLET DIADIAMETER DIAMETER DNDOWN DOWN DWDOMESTIC WATER DOMESTIC WATER DWGDRAWING DRAWING EAEACH EACH EFEACH FACE EACH FACE EWEACH WAY EACH WAY EQEQUAL EQUAL (E),EXST EXISTING EXST EXISTING EXTEXTERIOR EXTERIOR EXP.EXPANSION EXPANSION FF FINISHED FLOOR FINISHED FLOOR FGFINISHED GRADE FINISHED GRADE FTGFOOTING FOOTING FDNFOUNDATION FOUNDATION FLFLOW LINE FLOW LINE GGAS GAS GAGAGE GAGE GBGRADE BREAK GRADE BREAK HDPEHIGH DENSITY POLETHLENE HIGH DENSITY POLETHLENE HORIZHORIZONTAL HORIZONTAL IW INDUSTRIAL WASTE INDUSTRIAL WASTE INVINVERT INVERT JTJOINT JOINT LF L.F.LINEAR FEET LINEAR FEET LONGLONGITUDINAL LONGITUDINAL MFRMANUFACTURER MANUFACTURER MATLMATERIAL MATERIAL MAXMAXIMUM MAXIMUM MINMINIMUM MINIMUM NNORTH NORTH (N) NEW NEW NICNOT IN CONTRACT NOT IN CONTRACT NTSNOT TO SCALE NOT TO SCALE OCON CENTER ON CENTER OPNGOPENING OPENING OPPOPPOSITE OPPOSITE ODOUISIDE DIAMETER OUISIDE DIAMETER PCCPORTLAND CEMENT CONCRETE PORTLAND CEMENT CONCRETE PVMNTPAVEMENT PAVEMENT R RADIUS RADIUS REFREFERENCE REFERENCE RCRELATIVE COMPACTION RELATIVE COMPACTION SSLOPE SLOPE SDSTORM DRAIN STORM DRAIN SDCOSTORM DRAIN CLEAN OUT STORM DRAIN CLEAN OUT SSSANITARY SEWER SANITARY SEWER SWSTORMWATER STORMWATER SPECSPECIFICATION SPECIFICATION STDSTANDARD STANDARD STLSTEEL STEEL SYMMSYMMETRICAL SYMMETRICAL TOCTOP OF CONCRETE TOP OF CONCRETE TOSTOP OF STEEL TOP OF STEEL TC TOP OF CURB TOP OF CURB TDTRENCH DRAIN TRENCH DRAIN TGTOP OF GRATE TOP OF GRATE TPTOP OF PAVEMENT TOP OF PAVEMENT TYPTYPICAL TYPICAL TOTTOTAL TOTAL UONUNLESS OTHERWISE NOTED UNLESS OTHERWISE NOTED USTUNDERGROUND STORAGE TANK UNDERGROUND STORAGE TANK W/WITH WITH WWMWELDED WIRE MESH REINF. WELDED WIRE MESH REINF.
AutoCAD SHX Text
SECTION 4216/4217 OF THE GOVERNMENT CODE REQUIRES A DIGALERT IDENTIFICATION NUMBER BE ISSUED BEFORE A "PERMIT TO EXCAVATE" WILL BE VALID. FOR YOUR DIGALERT I.D. NUMBER CALL UNDERGROUND SERVICE ALERT TOLL FREE 1-800-642-2444 TWO WORKING DAYS BEFORE YOU DIG
AutoCAD SHX Text
CONTACT USA NORTH 811, UNDERGROUND SERVICE ALERT 48 HOURS BEFORE YOU DIG
AutoCAD SHX Text
811 or 800-642-2444 www.usanorth811.org
AutoCAD SHX Text
SITE NAME:GREYHOUND BUS STATION GREYHOUND BUS STATION
AutoCAD SHX Text
App'd
AutoCAD SHX Text
ISSUES/ REVISIONS
AutoCAD SHX Text
No.
AutoCAD SHX Text
Date
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
ACT DIVISION MANAGER:
AutoCAD SHX Text
A-E PROJECT MANAGER:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
CONTRACT #
AutoCAD SHX Text
ACT PROJECT MANAGER:
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
OAKLAND, CA
AutoCAD SHX Text
CAD FILE:
AutoCAD SHX Text
PROFESSIONAL SEAL:
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SIZE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
AC TRANSIT PROJECT NUMBER:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
D
AutoCAD SHX Text
C-0
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
TITLE SHEET
AutoCAD SHX Text
P2004
AutoCAD SHX Text
1-24-2020
AutoCAD SHX Text
1
AutoCAD SHX Text
9
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
X
AutoCAD SHX Text
LISA KIMURA
AutoCAD SHX Text
X
AutoCAD SHX Text
JASON AUYEUNG
AutoCAD SHX Text
2019-_____
AutoCAD SHX Text
REVISED SET
AutoCAD SHX Text
1-24-2020
Page 2: NUMBER D X AC TRANSIT BRT NORTHERN LAYOVER BREAKROOM · oakland, ca project # p2004 drawing index scope of project abbreviations applicable codes important notice u l u n d e r g

DPW

, CE

12/1

2/20

19 4

:37

PM19

R-1

18 C

0 - C

1.dw

g

REFERENCES:

7770 PARDEE LANE, SUITE 100OAKLAND, CA 94621

CHOW ENGINEERING, INC.

Phone: (510) 636-8500 Fax: (510) 636-8544

[email protected]://choweng.com

19R-118 C0 - C1

AutoCAD SHX Text
1.FIRE EXTINGUISHER: CONTRACTOR SHALL PROVIDE AND MAINTAIN AT LEASTE FIRE EXTINGUISHER: CONTRACTOR SHALL PROVIDE AND MAINTAIN AT LEASTE ONE (1) PORTABLE FIRE EXTINGUISHER OF THE TYPE SIZE APPROVED BY THE FIRE DEPARTMENT FIELD INSPECTOR AT THE JOB SITE THROUGHOUT CONSTRUCTION. 2.NO HAZARDOUS MATERIALS: NO HAZARDOUS CHEMICALS OR MATERIALS SHALL NO HAZARDOUS MATERIALS: NO HAZARDOUS CHEMICALS OR MATERIALS SHALL BE USED OR STORED IN THIS AREA OR ADJACENT AREAS TO THIS PROJECT. 3.COMPLY W/DRAWINGS: IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR COMPLY W/DRAWINGS: IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE, SUPERVISE, AND COMMUNICATE WITH THE ENGINEER, OWNER, AND SUBCONTRACTORS ALL WORK TO INSURE CONFORMANCE WITH THE APPROVED DRAWINGS AND SPECIFICATIONS. 4.HOT WORK: PRIOR WRITTEN APPROVAL AND HOT WORK PERMITS ARE REQUIRED HOT WORK: PRIOR WRITTEN APPROVAL AND HOT WORK PERMITS ARE REQUIRED FOR ALL FIELD WELDING AND HOT WORK OPERATIONS. 5.SITE CLEANLINESS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DAILY SITE CLEANLINESS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL AND LEGAL DISPOSAL OF ALL DEMOLITION SPOILS AND REMOVED MATERIALS. THE CONTRACTOR MAY NOT STOCKPILE OR STORE ANY NEW OR REMOVED MATERIAL ON SITE. 6.SITE CONTROL: MEASURES SHALL BE TAKEN TO PROTECT THE PUBLIC FROM SITE CONTROL: MEASURES SHALL BE TAKEN TO PROTECT THE PUBLIC FROM CONSTRUCTION ACTIVITIES AT ALL TIMES. 7.TEMPORARY FACILITIES: DURING CONSTRUCTION, CONTRACTOR SHALL PROVIDE TEMPORARY FACILITIES: DURING CONSTRUCTION, CONTRACTOR SHALL PROVIDE TWO (2) PORTAPOTTIES WITH HAND WASHING STATIONS FOR USE BY AC TRANSIT DRIVERS UNTIL BREAKROOM RESTROOMS ARE OPERATIONAL.
AutoCAD SHX Text
%%UCONSTRUCTION
AutoCAD SHX Text
%%uGENERAL NOTES
AutoCAD SHX Text
1.ALL WORK SHALL BE IN COMPLIANCE WITH THE 2019 CALIFORNIA BUILDING ALL WORK SHALL BE IN COMPLIANCE WITH THE 2019 CALIFORNIA BUILDING CODE, 2019 CALIFORNIA FIRE CODE, 2019 CALIFORNIA MECHANICAL CODE, 2019 CALIFORNIA ELECTRICAL CODE, 2019 CALIFORNIA PLUMBING CODE, AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL LAWS AND REGULATIONS. 2.THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 3.PRIOR TO COMMENCING CONSTRUCTION, THE CONTRACTOR SHALL VERIFY PRIOR TO COMMENCING CONSTRUCTION, THE CONTRACTOR SHALL VERIFY EXISTING DIMENSIONS, ELEVATIONS, AND CONDITIONS. INCLUDING CONDITIONS FOR GRADING, DRAINAGE AND UNDERGROUND FACILITIES. IF CONDITIONS DIFFER FROM THOSE SHOWN ON THE PLANS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND SHALL NOT BEGIN CONSTRUCTION UNTIL THE CHANGED CONDITIONS HAVE BEEN EVALUATED. 4.THE CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEW AND COORDINATION OF THE CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEW AND COORDINATION OF ALL PROJECT DOCUMENTS, DRAWINGS, AND SPECIFICATIONS PRIOR TO THE START OF CONSTRUCTION. ANY DISCREPANCIES, OMISSIONS, AND/OR CONFLICTS WITH CODE REQUIREMENTS SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE PRIOR TO THE START OF CONSTRUCTION SO THAT A CLARIFICATION CAN BE ISSUED. ANY WORK PERFORMED IN CONFLICT WITH THE CONTRACT DOCUMENTS OR IN CONFLICT WITH ANY CODE REQUIREMENTS SHALL BE CORRECTED BY THE CONTRACTOR AT THEIR OWN EXPENSE AND AT NO EXPENSE TO THE OWNER OR ENGINEER. 5.THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE ENGINEER, OWNER, THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE ENGINEER, OWNER, THEIR AGENTS, EMPLOYEES AND ASSOCIATED PARTIES HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. 6.ANY DEVIATION, SUBSTITUTION OR ALTERATION TO THE DESIGN SHALL BE ANY DEVIATION, SUBSTITUTION OR ALTERATION TO THE DESIGN SHALL BE SUBJECT TO REVIEW BY THE ENGINEER. 7.THE EXISTENCE, LOCATION AND CHARACTERISTICS OF UTILITY INFORMATION THE EXISTENCE, LOCATION AND CHARACTERISTICS OF UTILITY INFORMATION SHOWN HAS BEEN OBTAINED FROM A REVIEW OF AVAILABLE RECORDS DATA. NO REPRESENTATION IS MADE AS TO THE ACCURACY OR COMPLETENESS OF SAID UTILITY INFORMATION. THE CONSTRACTOR SHALL TAKE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES WHETHER SHOWN OR NOT ON THESE PLANS. 8.THE CONTRACTOR SHALL REPAIR OR REPLACE ANY DAMAGE TO EXISTING THE CONTRACTOR SHALL REPAIR OR REPLACE ANY DAMAGE TO EXISTING FACILITIES AND UTILITIES OCCURRING DURING THE COURSE OF DEMOLITION, EXCAVATION, OR CONSTRUCTION, WHETHER RESULTING DIRECTLY OR INDIRECTLY FROM THEIR OPERATIONS, WHETHER OR NOT SHOWN ON THESE DRAWINGS, WITHOUT ADDITIONAL COST TO THE OWNER. 9.DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE APPLIED, SUBJECT TO REVIEW BY THE ENGINEER. 10.THE CONTRACTOR SHALL SUBMIT "AS-BUILT" DRAWINGS TO AC TRANSIT UPON THE CONTRACTOR SHALL SUBMIT "AS-BUILT" DRAWINGS TO AC TRANSIT UPON COMPLETION OF WORK. RETENTIONS SHALL NOT BE RELEASED PRIOR TO THE CONTRACTOR'S SUBMITTAL OF APPROVED "AS-BUILTS".
AutoCAD SHX Text
BILL OF MATERIALS::
AutoCAD SHX Text
App'd
AutoCAD SHX Text
ISSUES/ REVISIONS
AutoCAD SHX Text
No.
AutoCAD SHX Text
Date
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
ACT DIVISION MANAGER:
AutoCAD SHX Text
A-E PROJECT MANAGER:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
CONTRACT #
AutoCAD SHX Text
ACT PROJECT MANAGER:
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
OAKLAND, CA
AutoCAD SHX Text
CAD FILE:
AutoCAD SHX Text
PROFESSIONAL SEAL:
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SIZE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
AC TRANSIT PROJECT NUMBER:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
D
AutoCAD SHX Text
C-1
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
P2004
AutoCAD SHX Text
1-24-2020
AutoCAD SHX Text
2
AutoCAD SHX Text
9
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
X
AutoCAD SHX Text
LISA KIMURA
AutoCAD SHX Text
X
AutoCAD SHX Text
JASON AUYEUNG
AutoCAD SHX Text
2019-_____
AutoCAD SHX Text
REVISED SET
AutoCAD SHX Text
1-24-2020
Page 3: NUMBER D X AC TRANSIT BRT NORTHERN LAYOVER BREAKROOM · oakland, ca project # p2004 drawing index scope of project abbreviations applicable codes important notice u l u n d e r g

Scale: 1:30DEMOLITION PLAN1

DPW

, CE

1/3/

2020

8:5

6 PM

19R

-118

C2

- C3.

dwg

REFERENCES:

7770 PARDEE LANE, SUITE 100OAKLAND, CA 94621

CHOW ENGINEERING, INC.

Phone: (510) 636-8500 Fax: (510) 636-8544

[email protected]://choweng.com

19R-118 C2 - C3

AutoCAD SHX Text
REMOVE AND DISPOSE OF TOILETS, SINKS, PARTITIANS, FIXTURES, AND LIGHTING FIXTURES,
AutoCAD SHX Text
DEMOLISH FLOOR SINKS, DRAINS, AND PLUMBING TO FLUSH WITH SURFACE. PLUG ABANDONED DRAINLINES WITH DRAIN PLUGS
AutoCAD SHX Text
REMOVE PIPING ABOVE FINISHED FLOOR USE EXISTING LINE FOR NEW FAUCETS
AutoCAD SHX Text
REMOVE EXIST ELECTRIC PANEL DIMMER SWITCH WIRRING GUTTER AND EXTERNAL CIRCUIT BREAKER PANEL
AutoCAD SHX Text
REMOVE PARTITIONS, WALLS, DOORS
AutoCAD SHX Text
REMOVE WALL COVE LIGHTING FIXTURES REMOVE EXISTING ELECTRICAL AND TELEPHONE RECEPTACLES THAT CANNOT BE REUSED
AutoCAD SHX Text
REMOVE EXIT SIGN 2 PLACES
AutoCAD SHX Text
EXIST BUILT OUT PLUMBING WALL TO REMAIN
AutoCAD SHX Text
REMOVE DOOR AND FRAME
AutoCAD SHX Text
REMOVE DOOR AND FRAME
AutoCAD SHX Text
REMOVE DOOR
AutoCAD SHX Text
EXIST PLUMBING VENT TO REMAIN
AutoCAD SHX Text
GREYHOUND EMPLOYEES ONLY AREA
AutoCAD SHX Text
GREYHOUND OFFICES
AutoCAD SHX Text
App'd
AutoCAD SHX Text
ISSUES/ REVISIONS
AutoCAD SHX Text
No.
AutoCAD SHX Text
Date
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
ACT DIVISION MANAGER:
AutoCAD SHX Text
A-E PROJECT MANAGER:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
CONTRACT #
AutoCAD SHX Text
ACT PROJECT MANAGER:
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
OAKLAND, CA
AutoCAD SHX Text
CAD FILE:
AutoCAD SHX Text
PROFESSIONAL SEAL:
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SIZE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
AC TRANSIT PROJECT NUMBER:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
D
AutoCAD SHX Text
C-2
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
DEMOLITION PLAN
AutoCAD SHX Text
P2004
AutoCAD SHX Text
1-24-2020
AutoCAD SHX Text
3
AutoCAD SHX Text
9
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
X
AutoCAD SHX Text
LISA KIMURA
AutoCAD SHX Text
X
AutoCAD SHX Text
JASON AUYEUNG
AutoCAD SHX Text
2020-_____
AutoCAD SHX Text
-
AutoCAD SHX Text
REVISED SET
AutoCAD SHX Text
1-24-2020
Page 4: NUMBER D X AC TRANSIT BRT NORTHERN LAYOVER BREAKROOM · oakland, ca project # p2004 drawing index scope of project abbreviations applicable codes important notice u l u n d e r g

Scale: 1:30FLOOR PLAN1

EX

IT

EX

IT

AC-4

CC-4

CC-4

BC-4

AC-5

DPW

, CE

1/3/

2020

8:5

6 PM

19R

-118

C2

- C3.

dwg

REFERENCES:

7770 PARDEE LANE, SUITE 100OAKLAND, CA 94621

CHOW ENGINEERING, INC.

Phone: (510) 636-8500 Fax: (510) 636-8544

[email protected]://choweng.com

19R-118 C3

AutoCAD SHX Text
EXTEND RAMP
AutoCAD SHX Text
WATER HEATERS
AutoCAD SHX Text
ELEC. PANEL
AutoCAD SHX Text
TABLE AND 2 CHAIRS
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
BREAKROOM TABLE/CHAIRS (BY OTHES)
AutoCAD SHX Text
LOUNGE TABLE/CHAIRS (BY OTHERS)
AutoCAD SHX Text
SINGLE USE, GENDER NEUTRAL, RESTROOMS
AutoCAD SHX Text
RESURFACE FLOOR (EPOXY COATING)
AutoCAD SHX Text
LEGEND: 1.KITCHEN CABINETS WITH ONE (1) CABINET LOCK KITCHEN CABINETS WITH ONE (1) CABINET LOCK 2.WATER FILTRATION SYSTEM UNDER SINK WATER FILTRATION SYSTEM UNDER SINK 3.COMMERCIAL GRADE FAUCET & SINK COMMERCIAL GRADE FAUCET & SINK 4.COUNTERTOP WITH BACKSPLASH COUNTERTOP WITH BACKSPLASH 5.TOE KICK TOE KICK 6.REFRIGERATOR REFRIGERATOR 7.MICROWAVE MICROWAVE 8.NEW TOILET WITH SENSOR NEW TOILET WITH SENSOR 9.NEW SINK (LAVATORY) NEW SINK (LAVATORY) 10.AUTOMATIC FAUCET WITH TEMPERATURE VALVE AUTOMATIC FAUCET WITH TEMPERATURE VALVE 11.SOAP DISPENSER SOAP DISPENSER 12.NEW TOILET PAPER DISPENSER - JUMBO ROLL NEW TOILET PAPER DISPENSER - JUMBO ROLL 13.NEW GRAB BARS NEW GRAB BARS 14.NEW TOILET SEAT COVER DISPENSER NEW TOILET SEAT COVER DISPENSER 15.AIR HAND DRYER AIR HAND DRYER 16.MIRROR WITH SHELF MIRROR WITH SHELF 17.TRASH BIN TRASH BIN 18.ALUMINUM SIGN ALUMINUM SIGN 19.MOTION SENSOR LIGHT MOTION SENSOR LIGHT 20.BULLETIN BOARD BULLETIN BOARD 21.BREAKROOM TABLE & 4 CHAIRS (BY OTHERS) BREAKROOM TABLE & 4 CHAIRS (BY OTHERS) 22.LOUNGE TABLE & 3 CHAIRS (BY OTHERS) LOUNGE TABLE & 3 CHAIRS (BY OTHERS) 23.TRASH CANS(BY OTHERS) TRASH CANS(BY OTHERS) 24.DESK AND CHAIRS (BY OTHERS) DESK AND CHAIRS (BY OTHERS) 25.PHONE (DESKTOP LANDLINE) (BY OTHERS) PHONE (DESKTOP LANDLINE) (BY OTHERS) 26.4'X5'X " GRADE A PLYWOOD MOUNTED 3' FROM FLOOR 4'X5'X " GRADE A PLYWOOD MOUNTED 3' FROM FLOOR 34" GRADE A PLYWOOD MOUNTED 3' FROM FLOOR 27.EQUIPEMENT MOUNTING RACK (PROVIDED BY AC TRANSIT) EQUIPEMENT MOUNTING RACK (PROVIDED BY AC TRANSIT) 28.NEW DOOR NEW DOOR 29.AC TRANSIT CARD READER BOX AC TRANSIT CARD READER BOX 30.SECURITY CAMERA SECURITY CAMERA 31.NEW EPOXY FLOOR COATING THROUGHOUT INTERIOR NEW EPOXY FLOOR COATING THROUGHOUT INTERIOR 32.NEW CONCRETE CURB WITH BARRIER RAILING NEW CONCRETE CURB WITH BARRIER RAILING 33.FINISH CONCRETE RAMP FINISH CONCRETE RAMP 34.NEW INTERIOR PAINT NEW INTERIOR PAINT 35.NEW ELECTRICAL PANEL NEW ELECTRICAL PANEL 36.NEW WATER HEATER NEW WATER HEATER 37.NEW MINI SPLIT NEW MINI SPLIT 38.NEW EMERGENCY EXIT LIGHTNEW EMERGENCY EXIT LIGHT
AutoCAD SHX Text
NEW CURB WITH BARRIER RAILING
AutoCAD SHX Text
EQUIP. RACK
AutoCAD SHX Text
USE EXISTING WATER LINE FOR NEW FAUCETS
AutoCAD SHX Text
CONNECT NEW KITCHEN FAUCET DRAINAGE TO EXISTING DRAINAGE
AutoCAD SHX Text
App'd
AutoCAD SHX Text
ISSUES/ REVISIONS
AutoCAD SHX Text
No.
AutoCAD SHX Text
Date
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
ACT DIVISION MANAGER:
AutoCAD SHX Text
A-E PROJECT MANAGER:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
CONTRACT #
AutoCAD SHX Text
ACT PROJECT MANAGER:
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
OAKLAND, CA
AutoCAD SHX Text
CAD FILE:
AutoCAD SHX Text
PROFESSIONAL SEAL:
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SIZE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
AC TRANSIT PROJECT NUMBER:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
D
AutoCAD SHX Text
C-3
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text
P2004
AutoCAD SHX Text
1-24-2020
AutoCAD SHX Text
4
AutoCAD SHX Text
9
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
X
AutoCAD SHX Text
LISA KIMURA
AutoCAD SHX Text
X
AutoCAD SHX Text
JASON AUYEUNG
AutoCAD SHX Text
2020-_____
AutoCAD SHX Text
REVISED SET
AutoCAD SHX Text
1-24-2020
Page 5: NUMBER D X AC TRANSIT BRT NORTHERN LAYOVER BREAKROOM · oakland, ca project # p2004 drawing index scope of project abbreviations applicable codes important notice u l u n d e r g

Scale: NTSBATHROOM ELEVATIONC

C-4Scale: NTSBATHROOM ELEVATIONB

C-4

Scale: 3/4" = 1'-0"KITCHEN ELEVATIONC

C-3

DPW

, CE

1/3/

2020

8:5

6 PM

19R

-118

C2

- C3.

dwg

REFERENCES:

7770 PARDEE LANE, SUITE 100OAKLAND, CA 94621

CHOW ENGINEERING, INC.

Phone: (510) 636-8500 Fax: (510) 636-8544

[email protected]://choweng.com

19R-118 C2 - C3

AutoCAD SHX Text
14
AutoCAD SHX Text
KEY: 1.KITCHEN CABINETS WITH ONE (1) CABINET LOCK KITCHEN CABINETS WITH ONE (1) CABINET LOCK 2.WATER FILTRATION SYSTEM UNDER SINK WATER FILTRATION SYSTEM UNDER SINK 3.COMMERCIAL GRADE FAUCET & SINK COMMERCIAL GRADE FAUCET & SINK 4.COUNTERTOP WITH BACKSPLASH COUNTERTOP WITH BACKSPLASH 5.TOE KICK TOE KICK 6.REFRIGERATOR REFRIGERATOR 7.MICROWAVE MICROWAVE 8.NEW TOILET WITH SENSOR NEW TOILET WITH SENSOR 9.NEW SINK (LAVATORY) NEW SINK (LAVATORY) 10.AUTOMATIC FAUCET WITH TEMPERATURE VALVE AUTOMATIC FAUCET WITH TEMPERATURE VALVE 11.SOAP DISPENSER SOAP DISPENSER 12.NEW TOILET PAPER DISPENSER - JUMBO ROLL NEW TOILET PAPER DISPENSER - JUMBO ROLL 13.NEW GRAB BARS NEW GRAB BARS 14.NEW TOILET SEAT COVER DISPENSER NEW TOILET SEAT COVER DISPENSER 15.AIR HAND DRYER AIR HAND DRYER 16.MIRROR WITH SHELF MIRROR WITH SHELF 17.TRASH BIN TRASH BIN 18.ALUMINUM SIGN ALUMINUM SIGN 19.MOTION SENSOR LIGHT MOTION SENSOR LIGHT 20.BULLETIN BOARD BULLETIN BOARD 21.BREAKROOM TABLE & 4 CHAIRS BREAKROOM TABLE & 4 CHAIRS 22.LOUNGE TABLE & 3 CHAIRS LOUNGE TABLE & 3 CHAIRS 23.TRASH CANS TRASH CANS 24.DESK AND CHAIRS DESK AND CHAIRS 25.PHONE (DESKTOP LANDLINE) PHONE (DESKTOP LANDLINE) 26.4'X5'X " GRADE A PLYWOOD MOUNTED 3' FROM FLOOR 4'X5'X " GRADE A PLYWOOD MOUNTED 3' FROM FLOOR 34" GRADE A PLYWOOD MOUNTED 3' FROM FLOOR 27.EQUIPEMENT MOUNTING RACK (PROVIDED BY AC TRANSIT) EQUIPEMENT MOUNTING RACK (PROVIDED BY AC TRANSIT) 28.NEW DOOR NEW DOOR 29.AC TRANSIT CARD READER BOX AC TRANSIT CARD READER BOX 30.SECURITY CAMERA SECURITY CAMERA 31.NEW EPOXY FLOOR COATING THROUGHOUT INTERIOR NEW EPOXY FLOOR COATING THROUGHOUT INTERIOR 32.NEW CONCRETE CURB WITH BARRIER RAILING NEW CONCRETE CURB WITH BARRIER RAILING 33.FINISH CONCRETE RAMP FINISH CONCRETE RAMP 34.NEW INTERIOR PAINT NEW INTERIOR PAINT 35.NEW ELECTRICAL PANEL NEW ELECTRICAL PANEL 36.NEW WATER HEATER NEW WATER HEATER 37.NEW MINI SPLIT NEW MINI SPLIT 38.NEW EMERGENCY EXIT LIGHTNEW EMERGENCY EXIT LIGHT
AutoCAD SHX Text
App'd
AutoCAD SHX Text
ISSUES/ REVISIONS
AutoCAD SHX Text
No.
AutoCAD SHX Text
Date
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
ACT DIVISION MANAGER:
AutoCAD SHX Text
A-E PROJECT MANAGER:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
CONTRACT #
AutoCAD SHX Text
ACT PROJECT MANAGER:
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
OAKLAND, CA
AutoCAD SHX Text
CAD FILE:
AutoCAD SHX Text
PROFESSIONAL SEAL:
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SIZE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
AC TRANSIT PROJECT NUMBER:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
D
AutoCAD SHX Text
C-4
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
INTERIOR ELEVATIONS
AutoCAD SHX Text
P2004
AutoCAD SHX Text
1-24-2020
AutoCAD SHX Text
5
AutoCAD SHX Text
9
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
-
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
X
AutoCAD SHX Text
LISA KIMURA
AutoCAD SHX Text
X
AutoCAD SHX Text
JASON AUYEUNG
AutoCAD SHX Text
2020-_____
AutoCAD SHX Text
-
AutoCAD SHX Text
REVISED SET
AutoCAD SHX Text
1-24-2020
Page 6: NUMBER D X AC TRANSIT BRT NORTHERN LAYOVER BREAKROOM · oakland, ca project # p2004 drawing index scope of project abbreviations applicable codes important notice u l u n d e r g

Scale: NTSEXTEND RAMPA

C3

Scale: NTSTYP. CONNECTION OF HVAC UNITB

M2

F

O

E

I

ACL

F

T

E

G

T

A

T

S

E

R

GIS

N

O

R

A

I

ER

E

N

I

S

P

D

E

R

E

R

F

O

L

A

N

O

I

S

N

E

No. C 054717

WANZEK

CIVIL

12/31/19

DEAN

Exp.

DPW

, CE

1/3/

2020

8:5

6 PM

19R

-118

C2

- C3.

dwg

REFERENCES:

7770 PARDEE LANE, SUITE 100OAKLAND, CA 94621

CHOW ENGINEERING, INC.

Phone: (510) 636-8500 Fax: (510) 636-8544

[email protected]://choweng.com

19R-118 C2 - C3

AutoCAD SHX Text
CONTINUE SLOPE OF EXISTING RAMP
AutoCAD SHX Text
F.F.
AutoCAD SHX Text
EMBED STEEL WIRE INTO EXISTING CONCRETE PRIOR TO POURING NEW CONCRETE
AutoCAD SHX Text
ROOF DECK
AutoCAD SHX Text
DURA BLOCK
AutoCAD SHX Text
LAG BASE PLATE TO DURA BLOCK WITH (1) M10 BOLT (TYP.)
AutoCAD SHX Text
App'd
AutoCAD SHX Text
ISSUES/ REVISIONS
AutoCAD SHX Text
No.
AutoCAD SHX Text
Date
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
ACT DIVISION MANAGER:
AutoCAD SHX Text
A-E PROJECT MANAGER:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
CONTRACT #
AutoCAD SHX Text
ACT PROJECT MANAGER:
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
OAKLAND, CA
AutoCAD SHX Text
CAD FILE:
AutoCAD SHX Text
PROFESSIONAL SEAL:
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SIZE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
AC TRANSIT PROJECT NUMBER:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
D
AutoCAD SHX Text
C-5
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
ELEVATIONS
AutoCAD SHX Text
P2004
AutoCAD SHX Text
1-24-2020
AutoCAD SHX Text
6
AutoCAD SHX Text
9
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
X
AutoCAD SHX Text
LISA KIMURA
AutoCAD SHX Text
X
AutoCAD SHX Text
STEVE STANLEY
AutoCAD SHX Text
2019-_____
AutoCAD SHX Text
REVISED SET
AutoCAD SHX Text
1-24-2020
Page 7: NUMBER D X AC TRANSIT BRT NORTHERN LAYOVER BREAKROOM · oakland, ca project # p2004 drawing index scope of project abbreviations applicable codes important notice u l u n d e r g

Scale: 1:30MECHANICAL PLAN2

EX

IT

EX

IT

DPW

, CE

1/3/

2020

8:5

6 PM

19R

-118

C2

- C3.

dwg

REFERENCES:

7770 PARDEE LANE, SUITE 100OAKLAND, CA 94621

CHOW ENGINEERING, INC.

Phone: (510) 636-8500 Fax: (510) 636-8544

[email protected]://choweng.com

19R-118 C2 - C3

AutoCAD SHX Text
ELEC. PANEL L1 PANEL L1
AutoCAD SHX Text
EQUIP. RACK
AutoCAD SHX Text
REPLACE VENTILATION FAN, CONNECT TO VENT TO OUTSIDE (PANASONIC FV-0511VQC1)
AutoCAD SHX Text
TRANE/MITSUBISHI ELECTRIC MODEL NTXWST06A112A 6,000 BTU WALL-MAUNTED INDOOR UNIT FOR MULTI-ZONE HEAT PUMP STATIONS
AutoCAD SHX Text
App'd
AutoCAD SHX Text
ISSUES/ REVISIONS
AutoCAD SHX Text
No.
AutoCAD SHX Text
Date
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
ACT DIVISION MANAGER:
AutoCAD SHX Text
A-E PROJECT MANAGER:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
CONTRACT #
AutoCAD SHX Text
ACT PROJECT MANAGER:
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
OAKLAND, CA
AutoCAD SHX Text
CAD FILE:
AutoCAD SHX Text
PROFESSIONAL SEAL:
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SIZE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
AC TRANSIT PROJECT NUMBER:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
D
AutoCAD SHX Text
M-1
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
MECHANICAL FLOOR PLAN
AutoCAD SHX Text
P2004
AutoCAD SHX Text
1-24-2020
AutoCAD SHX Text
7
AutoCAD SHX Text
9
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
BILL THOMPSON
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
X
AutoCAD SHX Text
LISA KIMURA
AutoCAD SHX Text
X
AutoCAD SHX Text
JASON AUYEUNG
AutoCAD SHX Text
2020-_____
AutoCAD SHX Text
REVISED SET
AutoCAD SHX Text
1-24-2020
Page 8: NUMBER D X AC TRANSIT BRT NORTHERN LAYOVER BREAKROOM · oakland, ca project # p2004 drawing index scope of project abbreviations applicable codes important notice u l u n d e r g

Scale: 1:30MECHANICAL ROOF PLAN2

BC-5

DPW

, CE

1/3/

2020

8:5

6 PM

19R

-118

C2

- C3.

dwg

REFERENCES:

7770 PARDEE LANE, SUITE 100OAKLAND, CA 94621

CHOW ENGINEERING, INC.

Phone: (510) 636-8500 Fax: (510) 636-8544

[email protected]://choweng.com

19R-118 C2 - C3

AutoCAD SHX Text
TRANE/MITSUBISHI ELECTRIC MODEL NTXWST06A112A 6,000 BTU WALL-MAUNTED INDOOR UNIT FOR MULTI-ZONE HEAT PUMP STATIONS
AutoCAD SHX Text
TRANE/MITSUBISHI ELECTRIC MODEL XYZ XYZ BTU MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM
AutoCAD SHX Text
PIPE DIAM. LIQUID/GAS
AutoCAD SHX Text
14 / 38
AutoCAD SHX Text
14 / 38
AutoCAD SHX Text
App'd
AutoCAD SHX Text
ISSUES/ REVISIONS
AutoCAD SHX Text
No.
AutoCAD SHX Text
Date
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
ACT DIVISION MANAGER:
AutoCAD SHX Text
A-E PROJECT MANAGER:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
CONTRACT #
AutoCAD SHX Text
ACT PROJECT MANAGER:
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
OAKLAND, CA
AutoCAD SHX Text
CAD FILE:
AutoCAD SHX Text
PROFESSIONAL SEAL:
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SIZE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
AC TRANSIT PROJECT NUMBER:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
D
AutoCAD SHX Text
M-2
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
MECHANICAL ROOF PLAN
AutoCAD SHX Text
P2004
AutoCAD SHX Text
1-24-2020
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
BILL THOMPSON
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
X
AutoCAD SHX Text
LISA KIMURA
AutoCAD SHX Text
X
AutoCAD SHX Text
JASON AUYEUNG
AutoCAD SHX Text
2020-_____
AutoCAD SHX Text
REVISED SET
AutoCAD SHX Text
1-24-2020
Page 9: NUMBER D X AC TRANSIT BRT NORTHERN LAYOVER BREAKROOM · oakland, ca project # p2004 drawing index scope of project abbreviations applicable codes important notice u l u n d e r g

Scale: NTSELECTRICAL PLAN2

EX

IT

EX

IT

GFI

GFIGFI

GFI

240V240V

240V240V

1

5

4

7 2

3

6

8

GFIGFI

GFI

GFI

D

D

D

D

DPW

, CE

1/3/

2020

8:5

6 PM

19R

-118

C2

- C3.

dwg

REFERENCES:

7770 PARDEE LANE, SUITE 100OAKLAND, CA 94621

CHOW ENGINEERING, INC.

Phone: (510) 636-8500 Fax: (510) 636-8544

[email protected]://choweng.com

19R-118 C2 - C3

AutoCAD SHX Text
ELEC. PANEL L1 PANEL L1
AutoCAD SHX Text
EQUIP. RACK
AutoCAD SHX Text
LEGEND: 25. PHONE (DESKTOP LANDLINE) 26. 4'X5'X " GRADE A PLYWOOD MOUNTED 3' FROM FLOOR 34" GRADE A PLYWOOD MOUNTED 3' FROM FLOOR 27. EQUIPMENT MOUNTING RACK (PROVIDED BY AC TRANSIT) 29. AC TRANSIT CARD READER BOX 30. SECURITY CAMERA 35. NEW ELECTRICAL PANEL 37. NEW MINI SPLIT 38. NEW EMERGENCY EXIT LIGHT 39. POWER STRIP 41. RESTROOM LIGHTS 43. BREAKROOM/KITCHEN LIGHTS
AutoCAD SHX Text
DUPLEX RECEPTACLE
AutoCAD SHX Text
DUPLEX GROUND FAULT INTERRUPTER
AutoCAD SHX Text
MULTI-OUTLET ASSEMBLY
AutoCAD SHX Text
CKT 3
AutoCAD SHX Text
CKT 2,4
AutoCAD SHX Text
PANEL CKT 15
AutoCAD SHX Text
PANEL CKT 7
AutoCAD SHX Text
PANEL CKT 9
AutoCAD SHX Text
PANEL CKT 11
AutoCAD SHX Text
PANEL CKT 5
AutoCAD SHX Text
240 VOLT OUTLET
AutoCAD SHX Text
CKT 1
AutoCAD SHX Text
PANEL L1 CKT 13
AutoCAD SHX Text
NOTE 1, TYP
AutoCAD SHX Text
CKT 19
AutoCAD SHX Text
CKT 23
AutoCAD SHX Text
CKT 17
AutoCAD SHX Text
NOTE 1
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
CKT 21
AutoCAD SHX Text
SWITCH
AutoCAD SHX Text
LIGHT FIXTURE
AutoCAD SHX Text
RECESSED LIGHT FIXTURE
AutoCAD SHX Text
240 VOLT OUTLET
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
NOTE 3
AutoCAD SHX Text
NOTE 1
AutoCAD SHX Text
ELECTRICAL SHEET NOTES 1.INSTALL 1" CONDUITS BETWEEN EACH CAMERA LOCATION AND INSTALL 1" CONDUITS BETWEEN EACH CAMERA LOCATION AND PLYWOOD PANEL IN ELECTRICAL ROOM. 2.ONE SWITCH FOR LIGHTS 1,2,3,4 OTHER SWITCH FOR LIGHTS ONE SWITCH FOR LIGHTS 1,2,3,4 OTHER SWITCH FOR LIGHTS 5,6,7,8. 3.ADDITIONAL SWITCH IS FOR EXISTING CORRIDOR LIGHTS. ADDITIONAL SWITCH IS FOR EXISTING CORRIDOR LIGHTS. 4.INSTALL 1" CONDUIT BETWEEN TELEPHONE OUTLET AND TELEPHONE INSTALL 1" CONDUIT BETWEEN TELEPHONE OUTLET AND TELEPHONE BOX ABOVE ELECTRICAL PANEL. 5.TANKLESS WATER HEATERS TO BE HARD-WIRED TO INDIVIDUAL 30A TANKLESS WATER HEATERS TO BE HARD-WIRED TO INDIVIDUAL 30A CIRCUITS WITH #10AWG SUPPLY CONDUCTORS AND GFI BREAKERS. 6.125 AMP PANEL SUPPLIED WITH 2-#1 + 1-#1AWG N + 1-#6 125 AMP PANEL SUPPLIED WITH 2-#1 + 1-#1AWG N + 1-#6 GROUND CONDUCTOR WITHIN 1.5" CONDUIT EXTENDING TO ELECTRICAL ROOM OF GREYHOUND TERMINAL. 7.BREAKROOM/KITCHEN LIGHTS TO HAVE EXTRA 3FT OF STRING BREAKROOM/KITCHEN LIGHTS TO HAVE EXTRA 3FT OF STRING (FUTURE DROP CEILING AT +11.5 FT ABOVE FF)+11.5 FT ABOVE FF)11.5 FT ABOVE FF)
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
120V, 30AMP WATER HEATER CONNECTION
AutoCAD SHX Text
NOTE 4
AutoCAD SHX Text
NOTE 6
AutoCAD SHX Text
CKT 8
AutoCAD SHX Text
NOTE 5 TYP.
AutoCAD SHX Text
CKT 12
AutoCAD SHX Text
PANEL CKT 6
AutoCAD SHX Text
NOTE 5
AutoCAD SHX Text
App'd
AutoCAD SHX Text
ISSUES/ REVISIONS
AutoCAD SHX Text
No.
AutoCAD SHX Text
Date
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
ACT DIVISION MANAGER:
AutoCAD SHX Text
A-E PROJECT MANAGER:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
CONTRACT #
AutoCAD SHX Text
ACT PROJECT MANAGER:
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
OAKLAND, CA
AutoCAD SHX Text
CAD FILE:
AutoCAD SHX Text
PROFESSIONAL SEAL:
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SIZE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
AC TRANSIT PROJECT NUMBER:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
D
AutoCAD SHX Text
E-1
AutoCAD SHX Text
BRT NORTHERN LAYOVER BREAKROOM
AutoCAD SHX Text
ELECTRICAL PLAN
AutoCAD SHX Text
P2004
AutoCAD SHX Text
1-24-2020
AutoCAD SHX Text
9
AutoCAD SHX Text
9
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
BILL THOMPSON
AutoCAD SHX Text
DEAN WANZEK
AutoCAD SHX Text
X
AutoCAD SHX Text
LISA KIMURA
AutoCAD SHX Text
X
AutoCAD SHX Text
JASON AUYEUNG
AutoCAD SHX Text
2020-_____
AutoCAD SHX Text
REVISED SET
AutoCAD SHX Text
1-24-2020