oc - sccp parameter set handling nokia

44
Nokia Siemens Networks Multimedia Gateway, Rel. U4.2, Product Documentation, v.4 OC - SCCP Parameter Set Handling DN986488 Issue 10-0

Upload: dejan-cosic

Post on 21-Apr-2015

185 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: OC - SCCP Parameter Set Handling Nokia

Nokia Siemens Networks Multimedia Gateway, Rel. U4.2, Product Documentation, v.4

OC - SCCP Parameter Set Handling

DN986488

Issue 10-0

Page 2: OC - SCCP Parameter Set Handling Nokia

2 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805804d0a35

The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.

The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.

This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2010/6/23. All rights reserved

f Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures.

Non-observance of these conditions and the safety instructions can result in personal injury or in property damage.

Therefore, only trained and qualified personnel may install and maintain the system.

The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards.

The same text in German:

Wichtiger Hinweis zur Produktsicherheit

In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Span-nung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.

Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverlet-zungen und Sachschäden führen.

Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet.

Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.

Page 3: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

3

OC - SCCP Parameter Set Handling

Id:0900d805804d0a35

Table of ContentsThis document has 44 pages.

Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

OC - SCCP PARAMETER SET HANDLING . . . . . . . . . . . . . . . . . . . . . . 7

OC - SCCP PARAMETER SET HANDLING . . . . . . . . . . . . . . . . . . . . . . 8

OCC CREATE SCCP SIGNALLING POINT PARAMETER SET . . . . . . 9

OCA CREATE SCCP SUBSYSTEM PARAMETER SET . . . . . . . . . . . 12

OCE COPY SCCP SIGNALLING POINT PARAMETER SET . . . . . . . . 15

OCF COPY SCCP SUBSYSTEM PARAMETER SET. . . . . . . . . . . . . . 19

OCM MODIFY SCCP SIGNALLING POINT PARAMETER SET. . . . . . 22

OCN MODIFY SCCP SUBSYSTEM PARAMETER SET . . . . . . . . . . . 25

OCR CHANGE SCCP PARAMETER SET NAME. . . . . . . . . . . . . . . . . 28

OCD DELETE SCCP SIGNALLING POINT PARAMETER SET . . . . . . 31

OCK DELETE SCCP SUBSYSTEM PARAMETER SET. . . . . . . . . . . . 34

OCI INTERROGATE SCCP SIGNALLING POINT PARAMETER SETS 37

OCJ INTERROGATE SCCP SUBSYSTEM PARAMETER SETS. . . . . 39

OCH HELP TEXT FOR SCCP SIGNALLING POINT PARAMETERS . 41

OCL HELP TEXT FOR SCCP SUBSYSTEM PARAMETERS . . . . . . . 43

Page 4: OC - SCCP Parameter Set Handling Nokia

4 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805804d0a35

Page 5: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

5

OC - SCCP Parameter Set Handling Summary of changes

Id:0900d805804b96f6

Summary of changesChanges between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.

Changes made between issues 10-0 and 9-0OCA CREATE SCCP SUBSYSTEM PARAMETER SET

The execution printout has been updated with 16 GT_RES_SPEC_HDL_RI_SSN.

OCF COPY SCCP SUBSYSTEM PARAMETER SET

The execution printout has been updated with 16 GT_RES_SPEC_HDL_RI_SSN.

OCN MODIFY SCCP SUBSYSTEM PARAMETER SET

A new error message has been added to the execution error messages.

OCK DELETE SCCP SUBSYSTEM PARAMETER SET

The execution printout has been updated with 16 GT_RES_SPEC_HDL_RI_SSN.

OCJ INTERROGATE SCCP SUBSYSTEM PARAMETER SETS

The execution printout has been updated with 16 GT_RES_SPEC_HDL_RI_SSN.

Changes made between issues 9–0 and 8–0OCA CREATE SCCP SUBSYSTEM PARAMETER SET

The execution printout updated.

OCC CREATE SCCP SIGNALLING POINT PARAMETER SET

The execution printout updated.

OCD DELETE SCCP SIGNALLING POINT PARAMETER SET

The execution printout updated.

OCE COPY SCCP SIGNALLING POINT PARAMETER SET

The execution printout updated.

OCF COPY SCCP SUBSYSTEM PARAMETER SET

The execution printout updated.

OCI INTERROGATE SCCP SIGNALLING POINT PARAMETER SETS

The execution printout updated.

OCJ INTERROGATE SCCP SUBSYSTEM PARAMETER SETS

The execution printout updated.

OCK DELETE SCCP SUBSYSTEM PARAMETER SET

The execution printout updated.

Changes made between issues 8-0 and 7-0OCA CREATE SCCP SUBSYSTEM PARAMETER SET

The Execution printout has been updated with 14 IMMEDIATE_STATE_INFO.

Page 6: OC - SCCP Parameter Set Handling Nokia

6 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805804b96f6

Summary of changes

OCF COPY SCCP SUBSYSTEM PARAMETER SET

The Execution printout has been updated with 14 IMMEDIATE_STATE_INFO.

OCK DELETE SCCP SUBSYSTEM PARAMETER SET

The Execution printout has been updated with 14 IMMEDIATE_STATE_INFO.

OCJ INTERROGATE SCCP SUBSYSTEM PARAMETER SETS

The Execution printout has been updated with 14 IMMEDIATE_STATE_INFO.

Changes made between issues 7-0 and 6-0OCA CREATE SCCP SUBSYSTEM PARAMETER SET

The execution printout updated.

OCF COPY SCCP SUBSYSTEM PARAMETER SET

The execution printout updated.

OCK DELETE SCCP SUBSYSTEM PARAMETER SET

The execution printout updated.

OCJ INTERROGATE SCCP SUBSYSTEM PARAMETER SETS

The execution printout updated.

Changes made between issues 6-0 and 5-0OCC CREATE SCCP SIGNALLING POINT PARAMETER SET

The execution printout updated.

OCE COPY SCCP SIGNALLING POINT PARAMETER SET

The execution printout updated.

OCD DELETE SCCP SIGNALLING POINT PARAMETER SET

The execution printout updated.

OCI INTERROGATE SCCP SIGNALLING POINT PARAMETER SET

The execution printout updated.

Page 7: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

7

OC - SCCP Parameter Set Handling OC - SCCP PARAMETER SET HANDLING

Id:0900d805802b2551

OC - SCCP PARAMETER SET HANDLINGYou can create new, copy, modify and interrogate the SCCP signalling point parameter set data and the SCCP subsystem parameter set data with the commands of this command group.

Menu of the command group:

SCCP PARAMETER SET HANDLING COMMANDS

? ..... DISPLAY MENUC: ..... CREATE SCCP SIGNALLING POINT PARAMETER SETA: ..... CREATE SCCP SUBSYSTEM PARAMETER SETE: ..... COPY SCCP SIGNALLING POINT PARAMETER SETF: ..... COPY SCCP SUBSYSTEM PARAMETER SETM: ..... MODIFY SCCP SIGNALLING POINT PARAMETER SETN: ..... MODIFY SCCP SUBSYSTEM PARAMETER SETR: ..... CHANGE SCCP PARAMETER SET NAMED: ..... DELETE SCCP SIGNALLING POINT PARAMETER SETK: ..... DELETE SCCP SUBSYSTEM PARAMETER SETI: ..... INTERROGATE SCCP SIGNALLING POINT PARAMETER SETSJ: ..... INTERROGATE SCCP SUBSYSTEM PARAMETER SETSH: ..... HELP TEXT FOR SCCP SIGNALLING POINT PARAMETERSL: ..... HELP TEXT FOR SCCP SUBSYSTEM PARAMETERSZ; ..... RETURN TO MAIN LEVEL

Page 8: OC - SCCP Parameter Set Handling Nokia

8 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805802da938

OC - SCCP PARAMETER SET HANDLING

OC - SCCP PARAMETER SET HANDLINGThe commands in this command group are:

OCC CREATE SCCP SIGNALLING POINT PARAMETER SET

OCA CREATE SCCP SUBSYSTEM PARAMETER SET

OCE COPY SCCP SIGNALLING POINT PARAMETER SET

OCF COPY SCCP SUBSYSTEM PARAMETER SET

OCM MODIFY SCCP SIGNALLING POINT PARAMETER SET

OCN MODIFY SCCP SUBSYSTEM PARAMETER SET

OCR CHANGE SCCP PARAMETER SET NAME

OCD DELETE SCCP SIGNALLING POINT PARAMETER SET

OCK DELETE SCCP SUBSYSTEM PARAMETER SET

OCI INTERROGATE SCCP SIGNALLING POINT PARAMETER SETS

OCJ INTERROGATE SCCP SUBSYSTEM PARAMETER SETS

OCH HELP TEXT FOR SCCP SIGNALLING POINT PARAMETERS

OCL HELP TEXT FOR SCCP SUBSYSTEM PARAMETERS

Page 9: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

9

OC - SCCP Parameter Set Handling OCC CREATE SCCP SIGNALLING POINT PARAME-TER SET

Id:0900d805804006d9

OCC CREATE SCCP SIGNALLING POINT PARAMETER SET

Function With this command you can create a new SCCP signalling point parameter set.

Parameters signalling point parameter set number, signalling point parameter set name;

Syntax

OCC: [<signalling point parameter set number> | <next free number> def],

<signalling point parameter set name> ;

Parameter explana-tions

signalling point parameter set number

The number of the SCCP signalling point parameter set you are creating. The default value is the next free parameter set number.

signalling point parameter set name

The name you wish to give the SCCP signalling point parameter set you are creating.

Examples 1. To create signalling point parameter set number 10, and give it the name ITU-T, give the following command:

OCC:10,ITU-T;

Additional informa-tion

If you do not enter a number for the signalling point parameter set, the system assigns it the next free parameter set number.

You must give a name for the signalling point parameter set you are creating. When the parameter set is created, the system gives the recommended values for the parameters.

Execution printouts The execution printout of the example 1 command is as follows:

CREATING SCCP SIGNALLING POINT PARAMETER SETDATA OF SCCP SIGNALLING POINT PARAMETER SET

SET NUMBER: 00010 SET NAME: ITU-T========================================================================NO: NAME VALUE UNIT--- ---- --------------------------- ------ 1 Q714_T_CONN_EST 90 1 S 2 Q714_T_IAS 90 1 S 3 Q714_T_IAR 270 1 S 4 Q714_T_REL 150 0.1 S 5 Q714_T_INT 60 1 S 6 Q714_T_RES 15 1 S 7 Q714_T_REP_REL 100 0.1 S 8 Q714_T_STAT_1ST 100 0.1 S 9 Q714_T_STAT_INC 300 0.1 S10 Q714_T_STAT_MAX 9000 0.1 S11 A_INTERFACE NO -12 WHITE_BOOK_MGMT_USED NO -13 SS_MANAGEMENT_USED YES -

Page 10: OC - SCCP Parameter Set Handling Nokia

10 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805804006d9

OCC CREATE SCCP SIGNALLING POINT PARAME-TER SET

14 XUDT_USED NO -15 UDT_DENIED NO -16 SEG_X_THRES 272 OCTETS17 SEG_Y_THRES 272 OCTETS18 TCAP_LOAD_SHARING_USED NO -19 ADD_DPC_IF_RI_SSN NO -20 ADD_GT_IF_RI_SSN NO -21 ADD_DPC_IF_RI_GT NO -22 ANALYSE_ROOT_OF_CALLING_GT NO -23 ALLOWED_GTI_VALUES 1-4 -24 SSA_FILTER_TIMER 10 0.1 S25 SSP_FILTER_TIMER 10 0.1 S26 LUDT_USED NO -27 CO_SEGM_USED NO -28 GT_ADDR_FIXED_LEN NO -

COMMAND EXECUTED

Semantic error messages

If an error occurs, the general semantic error messages of MML commands are output.

Execution error messages

During the command execution, minor and major errors may occur, preventing the exe-cution of the command.

Minor errors are indicated with the text COMMAND EXECUTION FAILED. If the require-ments for the command execution are not met, a minor error is concerned. A minor error may be detected, for example, when the system reads the files and checks the validity of the data. In these cases, file modifications have not occurred.

Major errors are indicated with the text COMMAND EXECUTION ABORTED. If the task defined in the command is partly completed before the interruption, a major error is con-cerned. In these cases, file modifications have possibly been already completed, and the files may contain indefinable data.

Minor errors include the following cases:

/*** ACTIVE UNIT STATE INCORRECT ***/

The state of the active unit is not WO-EX.

/*** ILLEGAL MESSAGE LENGTH BETWEEN SC4HAN AND SCXADM ***/

The length of the message sent by the SCCP Parameter Set Handling MML (SC4HAN) to the SCXADM is incorrect.

/*** ILLEGAL PARAMETER ***/

The SCXADM does not accept the value of a parameter.

/*** PASSIVE UNIT STATE INCORRECT ***/

The passive unit is in an indefinable state or in working state SP-RE.

/*** SEMIPERMANENT FILE UPDATING BUSY ***/

The updating of the semipermanent files is in progress.

/*** SIGNALLING POINT PARAMETER SET ALREADY EXISTS ***/

An attempt has been made to create a parameter set that already exists.

/*** SIGNALLING POINT PARAMETER SET NUMBER OUT OF PSPFIL ***/

Page 11: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

11

OC - SCCP Parameter Set Handling OCC CREATE SCCP SIGNALLING POINT PARAME-TER SET

Id:0900d805804006d9

The parameter set number is too high and indicates a set not included in the SCCP Sig-nalling Point Parameter File.

/*** SWITCHOVER ***/

A switchover is in progress.

/*** SWITCHOVER PREPARING ***/

A switchover preparation is in progress.

/*** INCORRECT PARAMETER SET NAME ***/

The name of the parameter set is incorrect.

/*** PARAMETER SET NAME ALREADY EXISTS ***/

The parameter set name already exists.

Major errors include the following cases:

/*** COMMUNICATION ERROR BETWEEN ACTIVE AND PASSIVESCXADM ***/

The communication between the active and passive SCXADMs failed.

/*** CONFLICT BETWEEN ACTIVE AND PASSIVE CM (CAC)FILES ***/

The data of the active CM or CAC file contradicts that of the passive CM or CAC file.

/*** DISK UPDATING FAILED ***/

The disk updating failed.

/*** DISTRIBUTION AND DISK UPDATING FAILED ***/

The data distribution and the disk updating failed.

/*** DISTRIBUTION ERROR ***/

The data distribution failed.

/*** FILE UPDATED ONLY IN ACTIVE CM (CAC) ***/

The files have been updated only in the active CM or CAC.

/*** INCORRECT MESSAGE ***/

The creation message received from the SCXADM is incorrect.

/*** SEMIPERMANENT FILE UPDATING FAILED ***/

The updating of the semipermanent files failed.

/*** TIME LIMIT EXCEEDED ***/

No reply is received within the time limit to the parameter set creation message sent by the SC4HAN.

Page 12: OC - SCCP Parameter Set Handling Nokia

12 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805804947f6

OCA CREATE SCCP SUBSYSTEM PARAMETER SET

OCA CREATE SCCP SUBSYSTEM PARAME-TER SET

Function With this command you can create a new SCCP subsystem parameter set.

Parameters subsystem parameter set number, subsystem parameter set name;

SyntaxOCA: [<subsystem parameter set number> | <next free number> def], <subsystem parameter set name> ;

Parameter explana-tions

subsystem parameter set number

The number of the SCCP subsystem parameter set you are creating. The default value is the next free parameter set number. When the parameter set is created, the system gives the recommended values for the parameters.

subsystem parameter set name

The name you wish to give the SCCP subsystem parameter set you are creating. This parameter is compulsory. When the parameter set is created, the parameters are given the recommended values.

Examples 1. To create subsystem parameter set number 10 and give it the name ITU-T, give the following command:

OCA:10,ITU-T;

Additional informa-tion

If you do not enter a number for the subsystem parameter set, the system assigns it the next free parameter set number.

Execution printouts The execution printout of the example 1 command is as follows:

CREATING SCCP SUBSYSTEM PARAMETER SETDATA OF SCCP SUBSYSTEM PARAMETER SET

SET NUMBER: 00010 SET NAME: ITU-T==========================================NO: NAME VALUE UNIT--- ---- ----- ------ 1 Q714_T_COORD_CHG 90 1 S 2 Q714_T_IGN_SST 60 1 S 3 A_INTERF_APPLIC NO - 4 A_INTERF_ERR_IGNORED NO - 5 TRANSLATION_SELECTION SCCP - 6 CALLING_ADDR_MODIFICATION NO - 7 CSCC_ALLOWED_OUT NO - 8 CSCC_ALLOWED_IN NO - 9 TRANSLATE_AT_DPC_IF_DPC_SSN_GT YES - 10 TC_TRANSACTION_IDS_THRESHOLD 75 PERCENTS 11 SEND_CALLING_SSN_IF_RI_SSN YES - 12 SEND_CALLING_SPC_SSN_IF_RI_GT YES - 13 KEEP_CLD_GT_IF_RI_SSN NO - 14 IMMEDIATE_STATE_INFO NO - 15 TC_PROTOCOL_VERS_EXCLUDED NO -

Page 13: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

13

OC - SCCP Parameter Set Handling OCA CREATE SCCP SUBSYSTEM PARAMETERSET

Id:0900d805804947f6

16 GT_RES_SPEC_HDL_RI_SSN NO -

COMMAND EXECUTED

Semantic error messages

If an error occurs, the general semantic error messages of MML commands are output.

Execution error messages

During the command execution, minor and major errors may occur, preventing the exe-cution of the command.

Minor errors are indicated with the text COMMAND EXECUTION FAILED. If the require-ments for the command execution are not met, a minor error is concerned. A minor error may be detected, for example, when the system reads the files and checks the validity of the data. In these cases, file modifications have not occurred.

Major errors are indicated with the text COMMAND EXECUTION ABORTED. If the task defined in the command is partly completed before the interruption, a major error is con-cerned. In these cases, file modifications have possibly been already completed, and the files may contain indefinable data.

Minor errors include the following cases:

/*** ACTIVE UNIT STATE INCORRECT ***/

The state of the active unit is not WO-EX.

/*** ILLEGAL MESSAGE LENGTH BETWEEN SC4HAN AND SCXADM ***/

The length of the message sent by the SCCP Parameter Set Handling MML (SC4HAN) to the SCXADM is incorrect.

/*** ILLEGAL PARAMETER ***/

The SCXADM does not accept the value of a parameter.

/*** PASSIVE UNIT STATE INCORRECT ***/

The passive unit is in an indefinable state or in working state SP-RE.

/*** SEMIPERMANENT FILE UPDATING BUSY ***/

The updating of the semipermanent files is in progress.

/*** SUBSYSTEM PARAMETER SET ALREADY EXISTS ***/

An attempt has been made to create a parameter set that already exists.

/*** SUBSYSTEM PARAMETER SET NUMBER OUT OF PSSFIL ***/

The parameter set number is too high and indicates a set not included in the SCCP Sub-system Parameter File.

/*** SWITCHOVER ***/

A switchover is in progress.

/*** SWITCHOVER PREPARING ***/

A switchover preparation is in progress.

/*** INCORRECT PARAMETER SET NAME ***/

The parameter set name is incorrect.

/*** PARAMETER SET NAME ALREADY EXISTS ***/

The parameter set name already exists.

Major errors include the following cases:

Page 14: OC - SCCP Parameter Set Handling Nokia

14 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805804947f6

OCA CREATE SCCP SUBSYSTEM PARAMETER SET

/*** COMMUNICATION ERROR BETWEEN ACTIVE AND PASSIVESCXADM ***/

The communication between the active and passive SCXADMs failed.

/*** DISK UPDATING FAILED ***/

The disk updating failed.

/*** DISTRIBUTION AND DISK UPDATING FAILED ***/

The data distribution and the disk updating failed.

/*** DISTRIBUTION ERROR ***/

The data distribution failed.

/*** FILE UPDATED ONLY IN ACTIVE CM (CAC) ***/

The files have been updated only in the active CM or CAC.

/*** FILE UPDATED ONLY IN PASSIVE CM (CAC) ***/

The files have been updated only in the passive CM or CAC.

/*** INCORRECT MESSAGE ***/

The creation message received from the SCXADM is incorrect.

/*** SEMIPERMANENT FILE UPDATING FAILED ***/

The updating of the semipermanent files failed.

/*** TIME LIMIT EXCEEDED ***/

No reply is received within the time limit to the parameter set creation message sent by the SC4HAN.

Page 15: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

15

OC - SCCP Parameter Set Handling OCE COPY SCCP SIGNALLING POINT PARAMETERSET

Id:0900d80580417226

OCE COPY SCCP SIGNALLING POINT PARAMETER SET

Function With this command you can create a new SCCP signalling point parameter set by copying an existing SCCP signalling point parameter set.

Parameters source signalling point parameter set number, source signalling point parameter set name: signalling point parameter set number, signalling point parameter set name;

Syntax

OCE: (<source signalling point parameter set number> |

<source signalling point parameter set name> ) :

[<signalling point parameter set number> | <next free number>def],

<signalling point parameter set name>;

Parameter explana-tions

source signalling point parameter set number

The number of the parameter set you wish to copy. The parameter set number is an alternative to the parameter set name.

source signalling point parameter set name

The name of the parameter set you wish to copy. The parameter set name is an alter-native to the set number. You cannot give the name and the number simultaneously.

signalling point parameter set number

The number of the SCCP signalling point parameter set you are creating. The default value is the next free parameter set number.

signalling point parameter set name

The name you wish to give the SCCP signalling point parameter set you are creating. This parameter is compulsory.

Examples 1. To create SCCP signalling point parameter set number 10 by copying parameter set 1, give the following command:

OCE:1:10,CCITT;

Additional informa-tion

If you do not enter a number for the SCCP signalling point parameter set, the system assigns it the next free parameter set number.

Execution printouts The execution printout of the example 1 command is as follows:

COPYING SCCP SIGNALLING POINT PARAMETER SETDATA OF SCCP SIGNALLING POINT PARAMETER SET

SET NUMBER: 00010 SET NAME: CCITT========================================================================NO: NAME VALUE UNIT--- ---- --------------------------- ------

Page 16: OC - SCCP Parameter Set Handling Nokia

16 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d80580417226

OCE COPY SCCP SIGNALLING POINT PARAMETER SET

1 Q714_T_CONN_EST 90 1 S 2 Q714_T_IAS 90 1 S 3 Q714_T_IAR 270 1 S 4 Q714_T_REL 150 0.1 S 5 Q714_T_INT 60 1 S 6 Q714_T_RES 15 1 S 7 Q714_T_REP_REL 100 0.1 S 8 Q714_T_STAT_1ST 100 0.1 S 9 Q714_T_STAT_INC 300 0.1 S 10 Q714_T_STAT_MAX 9000 0.1 S 11 A_INTERFACE YES - 12 WHITE_BOOK_MGMT_USED NO - 13 SS_MANAGEMENT_USED YES - 14 XUDT_USED NO - 15 UDT_DENIED NO - 16 SEG_X_THRES 272 OCTETS 17 SEG_Y_THRES 272 OCTETS 18 TCAP_LOAD_SHARING_USED NO - 19 ADD_DPC_IF_RI_SSN NO - 20 ADD_GT_IF_RI_SSN NO - 21 ADD_DPC_IF_RI_GT NO - 22 ANALYSE_ROOT_OF_CALLING_GT NO - 23 ALLOWED_GTI_VALUES 1-4,5,6,7,8,9,10,11, - 12,13,14,15 - 24 SSA_FILTER_TIMER 10 0.1 S 25 SSP_FILTER_TIMER 10 0.1 S 26 LUDT_USED NO - 27 CO_SEGM_USED NO - 28 GT_ADDR_FIXED_LEN NO -

COMMAND EXECUTED

Semantic error messages

/*** SIGNALLING POINT PARAMETER SET DOES NOT EXIST ***/

The parameter set you wish to copy does not exist.

In addition, the general semantic error messages of MML commands are used.

Execution error messages

During the command execution, minor and major errors may occur, preventing the exe-cution of the command.

Minor errors are indicated with the text COMMAND EXECUTION FAILED. If the require-ments for the command execution are not met, a minor error is concerned. A minor error may be detected, for example, when the system the files and checks the validity of the data. In these cases, file modifications have not occurred.

Major errors are indicated with the text COMMAND EXECUTION ABORTED. If the task defined in the command is partly completed before the interruption, a major error is con-cerned. In these cases, file modifications have possibly been already completed, and the files may contain indefinable data.

Minor errors include the following cases:

/*** ACTIVE UNIT STATE INCORRECT ***/

The state of the active unit is not WO-EX.

Page 17: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

17

OC - SCCP Parameter Set Handling OCE COPY SCCP SIGNALLING POINT PARAMETERSET

Id:0900d80580417226

/*** ILLEGAL MESSAGE LENGTH BETWEEN SC4HAN AND SCXADM ***/

The length of the message sent by the SCCP Parameter Set Handling MML (SC4HAN) to the SCXADM is incorrect.

/*** ILLEGAL PARAMETER ***/

The SCXADM does not accept the value of a parameter.

/*** PASSIVE UNIT STATE INCORRECT ***/

The passive unit is in an indefinable state or in working state SP-RE.

/*** SEMIPERMANENT FILE UPDATING BUSY ***/

The updating of the semipermanent files is in progress.

/*** SIGNALLING POINT PARAMETER SET ALREADY EXISTS ***/

An attempt has been made to create a parameter set that already exists.

/*** SIGNALLING POINT PARAMETER SET NUMBER OUT OFPSPFIL ***/

The parameter set number is too high and indicates a set not included in the SCCP Sig-nalling Point Parameter File.

/*** SWITCHOVER ***/

A switchover is in progress.

/*** SWITCHOVER PREPARING ***/

A switchover preparation is in progress.

/*** SIGNALLING POINT PARAMETER SET DOES NOT EXIST ***/

The signalling point parameter set does not exist.

/*** INCORRECT PARAMETER SET NAME ***/

The parameter set name is incorrect.

/*** PARAMETER SET NAME ALREADY EXISTS ***/

The parameter set name already exists.

Major errors include the following cases:

/*** COMMUNICATION ERROR BETWEEN ACTIVE AND PASSIVESCXADM ***/

The communication between the active and passive SCXADMs failed.

/*** DISK UPDATING FAILED ***/

The disk updating failed.

/*** DISTRIBUTION AND DISK UPDATING FAILED ***/

The data distribution and the disk updating failed.

/*** DISTRIBUTION ERROR ***/

The data distribution failed.

/*** FILE UPDATED ONLY IN ACTIVE CM (CAC) ***/

The files have been updated only in the active CM or CAC.

/*** FILE UPDATED ONLY IN PASSIVE CM (CAC) ***/

The files have been updated only in the passive CM or CAC.

/*** INCORRECT MESSAGE ***/

Page 18: OC - SCCP Parameter Set Handling Nokia

18 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d80580417226

OCE COPY SCCP SIGNALLING POINT PARAMETER SET

The creation message received from the SCXADM is incorrect.

/*** SEMIPERMANENT FILE UPDATING FAILED ***/

The updating of the semipermanent files failed.

/*** TIME LIMIT EXCEEDED ***/

No reply is received within the time limit to the parameter set creation message sent by the SC4HAN.

Page 19: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

19

OC - SCCP Parameter Set Handling OCF COPY SCCP SUBSYSTEM PARAMETER SET

Id:0900d805804cc740

OCF COPY SCCP SUBSYSTEM PARAMETER SET

Function With this command you can create a new SCCP subsystem parameter set by copying an existing SCCP subsystem parameter set.

Parameters source subsystem parameter set number, source subsystem parameter set name: sub-system parameter set number, subsystem parameter set name;

Syntax

OCF: (<source system parameter set number> |

<source system parameter set name> ) :

[<subsystem parameter set number> | <next free number> def] ,

<subsystem parameter set name> ;

Parameter explana-tions

source subsystem parameter set number

The number of the set you wish to copy. The parameter set number is an alternative to the set name.

source subsystem parameter set name

The name of the set you wish to copy. The parameter set name is an alternative to the set number. The name and the number cannot be given simultaneously.

subsystem parameter set number

The number of the SCCP subsystem parameter set you are creating. The default value is the next free parameter set number.

subsystem parameter set name

The name you wish to give the SCCP subsystem parameter set you are creating. This parameter is compulsory.

Examples 1. To create SCCP subsystem parameter set number 10 by copying parameter set 1, give the following command:

OCF:1:10,CCITT;

Additional informa-tion

If you do not enter a number for the subsystem parameter set, the system assigns the next free parameter set number for it.

Execution printouts The execution printout of the example 1 command is as follows:

COPYING SCCP SUBSYSTEM PARAMETER SETDATA OF SCCP SUBSYSTEM PARAMETER SET

SET NUMBER: 00010 SET NAME: CCITT==========================================NO: NAME VALUE UNIT--- ---- ----- ------

Page 20: OC - SCCP Parameter Set Handling Nokia

20 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805804cc740

OCF COPY SCCP SUBSYSTEM PARAMETER SET

1 Q714_T_COORD_CHG 90 1 S 2 Q714_T_IGN_SST 60 1 S 3 A_INTERF_APPLIC YES - 4 A_INTERF_ERR_IGNORED YES - 5 TRANSLATION_SELECTION SCCP - 6 CALLING_ADDR_MODIFICATION NO - 7 CSCC_ALLOWED_OUT NO - 8 CSCC_ALLOWED_IN NO - 9 TRANSLATE_AT_DPC_IF_DPC_SSN_GT YES - 10 TC_TRANSACTION_IDS_THRESHOLD 75 PERCENTS 11 SEND_CALLING_SSN_IF_RI_SSN YES - 12 SEND_CALLING_SPC_SSN_IF_RI_GT YES - 13 KEEP_CLD_GT_IF_RI_SSN NO - 14 IMMEDIATE_STATE_INFO NO - 15 TC_PROTOCOL_VERS_EXCLUDED NO - 16 GT_RES_SPEC_HDL_RI_SSN NO -

COMMAND EXECUTED

Semantic error messages

/*** SUBSYSTEM PARAMETER SET DOES NOT EXIST ***/

The parameter set you wish to copy does not exist.

In addition, the general semantic error messages of MML commands are used.

Execution error messages

During the command execution, minor and major errors may occur, preventing the exe-cution of the command.

Minor errors are indicated with the text COMMAND EXECUTION FAILED. If the require-ments for the command execution are not met, a minor error is concerned. A minor error may be detected, for example, when the system reads the files and checks the validity of the data. In these cases, file modifications have not occurred.

Major errors are indicated with the text COMMAND EXECUTION ABORTED. If the task defined in the command is partly completed before the interruption, a major error is con-cerned. In these cases, file modifications have possibly been already completed, and the files may contain indefinable data.

Minor errors include the following cases:

/*** ACTIVE UNIT STATE INCORRECT ***/

The state of the active unit is not WO-EX.

/*** ILLEGAL MESSAGE LENGTH BETWEEN SC4HAN AND SCXADM ***/

The length of the message sent by the SCCP Parameter Set Handling MML (SC4HAN) to the SCXADM is incorrect.

/*** ILLEGAL PARAMETER ***/

The SCXADM does not accept the value of a parameter.

/*** PASSIVE UNIT STATE INCORRECT ***/

The passive unit is in an indefinable state or in working state SP-RE.

/*** SEMIPERMANENT FILE UPDATING BUSY ***/

The updating of the semipermanent files is in progress.

/*** SUBSYSTEM PARAMETER SET ALREADY EXISTS ***/

Page 21: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

21

OC - SCCP Parameter Set Handling OCF COPY SCCP SUBSYSTEM PARAMETER SET

Id:0900d805804cc740

An attempt has been made to create a parameter set that already exists.

/*** SUBSYSTEM PARAMETER SET NUMBER OUT OF PSSFIL ***/

The parameter set number is too high and indicates a set not included in the SCCP Sig-nalling Point Parameter File.

/*** SWITCHOVER ***/

A switchover is in progress.

/*** SWITCHOVER PREPARING ***/

A switchover preparation is in progress.

/*** SUBSYSTEM PARAMETER SET DOES NOT EXIST ***/

The subsystem parameter set does not exist.

/*** INCORRECT PARAMETER SET NAME ***/

The parameter set name is incorrect.

/*** PARAMETER SET NAME ALREADY EXISTS ***/

The parameter set name already exists.

Major errors include the following cases:

/*** COMMUNICATION ERROR BETWEEN ACTIVE AND PASSIVESCXADM ***/

The communication between the active and passive SCXADMs failed.

/*** CONFLICT BETWEEN ACTIVE AND PASSIVE CM (CAC)FILES ***/

The data of the active CM or CAC file contradicts that of the passive CM or CAC file.

/*** DISK UPDATING FAILED ***/

The disk updating failed.

/*** DISTRIBUTION AND DISK UPDATING FAILED ***/

The data distribution and the disk updating failed.

/*** DISTRIBUTION ERROR ***/

The data distribution failed.

/*** FILE UPDATED ONLY IN ACTIVE CM (CAC) ***/

The files have been updated only in the active CM or CAC.

/*** INCORRECT MESSAGE ***/

The message received from the SCXADM is incorrect.

/*** SEMIPERMANENT FILE UPDATING FAILED ***/

The updating of the semipermanent files failed.

/*** TIME LIMIT EXCEEDED ***/

No reply is received within the time limit to the parameter set creation message sent by the SC4HAN.

Page 22: OC - SCCP Parameter Set Handling Nokia

22 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d80580282f7b

OCM MODIFY SCCP SIGNALLING POINT PARAME-TER SET

OCM MODIFY SCCP SIGNALLING POINT PARAMETER SET

Function With this command you can modify the parameter values of an existing SCCP signalling point parameter set.

Parameters signalling point parameter set number, signalling point parameter set name: parameter number, parameter value;

Syntax OCM: (<signalling point parameter set number> |

<signalling point parameter set name>) :

<parameter number>, <parameter value>;

Parameter explana-tions

signalling point parameter set number

The number of the parameter set whose parameter values you wish to modify. The parameter set number is an alternative to the parameter set name (next parameter).

signalling point parameter set name

The name of the parameter set whose parameter values you wish to modify. The param-eter set name is an alternative to the parameter set number. You cannot give the name and the number simultaneously.

parameter number

The number of the parameter whose value you want to modify. This parameter is com-pulsory.

parameter value

The new parameter value. This parameter is compulsory.

Examples 1. To modify the value of parameter 3 to 200 in parameter set 7, give the following command:

OCM:7:3,200;

Execution printouts The execution printout of the example 1 command is as follows:

MODIFYING SCCP SIGNALLING POINT PARAMETER SET SET NUMBER: 00007 SET NAME: ITU-T ========================================================NO: NAME OLD VALUE NEW VALUE --- ---- --------- --------- 3 Q714_T_IAR 270 200

COMMAND EXECUTED

Semantic error messages

/*** SIGNALLING POINT PARAMETER SET DOES NOT EXIST ***/

The parameter set you wish to modify does not exist.

In addition, the general semantic error messages of MML commands are used.

Execution error messages

During the command execution, minor and major errors may occur, preventing the exe-cution of the command.

Page 23: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

23

OC - SCCP Parameter Set Handling OCM MODIFY SCCP SIGNALLING POINT PARAME-TER SET

Id:0900d80580282f7b

Minor errors are indicated with the text COMMAND EXECUTION FAILED. If the require-ments for the command execution are not met, a minor error is concerned. A minor error may be detected, for example, when the system reads the files and checks the validity of the data. In these cases, file modifications have not occurred.

Major errors are indicated with the text COMMAND EXECUTION ABORTED. If the task defined in the command is partly completed before the interruption, a major error is con-cerned. In these cases, file modifications have possibly been already completed, and the files may contain indefinable data.

Minor errors include the following cases:

/*** ACTIVE UNIT STATE INCORRECT ***/

The state of the active unit is not WO-EX.

/*** ILLEGAL MESSAGE LENGTH BETWEEN SC4HAN AND SCXADM ***/

The length of the message sent by the SCCP Parameter Set Handling MML (SC4HAN) to the SCXADM is incorrect.

/*** ILLEGAL PARAMETER ***/

The SCXADM does not accept the value of a parameter.

/*** PASSIVE UNIT STATE INCORRECT ***/

The passive unit is in an indefinable state or in working state SP-RE.

/*** SEMIPERMANENT FILE UPDATING BUSY ***/

The updating of the semipermanent files is in progress.

/*** SIGNALLING POINT ACTIVATION NOT DENIED ***/

The signalling point was not set to the UA-INU state before the modification of its param-eter set was attempted.

/*** SWITCHOVER ***/

A switchover is in progress.

/*** SWITCHOVER PREPARING ***/

A switchover preparation is in progress.

/*** SIGNALLING POINT PARAMETER SET DOES NOT EXIST ***/

The signalling point parameter set does not exist.

/*** INCORRECT PARAMETER SET NAME ***/

The parameter set name is incorrect.

Major errors include the following cases:

/*** COMMUNICATION ERROR BETWEEN ACTIVE AND PASSIVE SCXADM ***/

The communication between the active and passive SCXADMs failed.

/*** COMMUNICATION ERROR BETWEEN ACTIVE SCXADM AND ACTIVE CCUPDA ***/

The communication between the active SCXADM and the active Updating Program Block for Common Channel Signalling (CCUPDA) failed.

/*** COMMUNICATION ERROR BETWEEN PASSIVE SCXADM AND PASSIVE CCUPDA ***/

The communication between the passive SCXADM and the passive CCUPDA failed./*** CONFLICT BETWEEN ACTIVE AND PASSIVE CM (CAC) FILES ***/

Page 24: OC - SCCP Parameter Set Handling Nokia

24 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d80580282f7b

OCM MODIFY SCCP SIGNALLING POINT PARAME-TER SET

The data of the active CM or CAC file contradicts that of the passive CM or CAC file.

/*** DISK UPDATING FAILED ***/

The disk updating failed.

/*** DISTRIBUTION AND DISK UPDATING FAILED ***/

The data distribution and the disk updating failed.

/*** DISTRIBUTION ERROR ***/

The data distribution failed.

/*** FILE UPDATED ONLY IN ACTIVE CM (CAC) ***/

The files have been updated only in the active CM or CAC.

/*** INCORRECT MESSAGE ***/

The creation message received from the SCXADM is incorrect.

/*** SEMIPERMANENT FILE UPDATING FAILED ***/

The updating of the semipermanent files failed.

/*** TIME LIMIT EXCEEDED ***/

No reply is received within the time limit to the parameter set data modification or inquiry message sent by the SC4HAN.

Page 25: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

25

OC - SCCP Parameter Set Handling OCN MODIFY SCCP SUBSYSTEM PARAMETERSET

Id:0900d805804f02e6

OCN MODIFY SCCP SUBSYSTEM PARAME-TER SET

Function With this command you can modify the parameter values of an existing SCCP subsys-tem parameter set.

Parameters subsystem parameter set number, subsystem parameter set name: parameter number, parameter value;

Syntax

OCN: (<subsystem parameter set number> |

<subsystem parameter set name>) :

<parameter number>, <parameter value> ;

Parameter explana-tions

subsystem parameter set number

The number of the parameter set whose parameter values you wish to modify. The parameter set number is an alternative to the parameter set name (next parameter).

subsystem parameter set name

The name of the subsystem parameter set whose parameter values you wish to modify. The parameter set name is an alternative to the parameter set number. You cannot give the name and the number simultaneously.

parameter number

The parameter number whose value you wish to modify. This parameter is compulsory.

parameter value

The new parameter value. This parameter is compulsory.

Examples 1. To modify the value of parameter 2 to 120 in parameter set 11, give the following command:

OCN:11:2,120;

Execution printouts The execution printout of the example 1 command is as follows:

MODIFYING SCCP SUBSYSTEM PARAMETER SET SET NUMBER: 00011 SET NAME: ITU-T========================================================NO: NAME OLD VALUE NEW VALUE--- ---- --------- --------- 2 Q714_T_IGN_SST 60 120

COMMAND EXECUTED

Semantic error messages

/*** SUBSYSTEM PARAMETER SET DOES NOT EXIST ***/

The parameter set you wish to modify does not exist.

In addition, the general semantic error messages of MML commands are used.

Page 26: OC - SCCP Parameter Set Handling Nokia

26 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805804f02e6

OCN MODIFY SCCP SUBSYSTEM PARAMETER SET

Execution error messages

During the command execution, minor and major errors may occur, preventing the exe-cution of the command.

Minor errors are indicated with the text COMMAND EXECUTION FAILED. If the require-ments for the command execution are not met, a minor error is concerned. A minor error may be detected, for example, when the system reads the files and checks the validity of the data. In these cases, file modifications have not occurred.

Major errors are indicated with the text COMMAND EXECUTION ABORTED. If the task defined in the command is partly completed before the interruption, a major error is con-cerned. In these cases, file modifications have possibly been already completed, and the files may contain indefinable data.

Minor errors include the following cases:

/*** ACTIVE UNIT STATE INCORRECT ***/

The state of the active unit is not WO-EX.

/*** ILLEGAL MESSAGE LENGTH BETWEEN SC4HAN AND SCXADM ***/

The length of the message sent by the SCCP Parameter Set Handling MML (SC4HAN) to the SCXADM is incorrect.

/*** ILLEGAL PARAMETER ***/

The SCXADM does not accept the value of a parameter.

/*** PASSIVE UNIT STATE INCORRECT ***/

The passive unit is in an indefinable state or in working state SP-RE.

/*** SEMIPERMANENT FILE UPDATING BUSY ***/

The updating of the semipermanent files is in progress.

/*** SUBSYSTEM ACTIVATION NOT DENIED ***/

The subsystem was not set to the UA-INU state before the modification of its parameter set was attempted.

/*** SWITCHOVER ***/

A switchover is in progress.

/*** SWITCHOVER PREPARING ***/

A switchover preparation is in progress.

/*** SUBSYSTEM PARAMETER SET DOES NOT EXIST ***/

The subsystem parameter set does not exist.

/*** INCORRECT PARAMETER SET NAME ***/

The name of the parameter set is incorrect.

/*** OPERATIONS NOT ALLOWED ***/

The parameter is optional and the option in question is not activated.

Major errors include the following cases:

/*** COMMUNICATION ERROR BETWEEN ACTIVE AND PASSIVE SCXADM ***/

The communication between the active and passive SCXADMs failed./*** CONFLICT BETWEEN ACTIVE AND PASSIVE CM (CAC) FILES ***/

The data of the active CM or CAC file contradicts that of the passive CM or CAC file.

Page 27: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

27

OC - SCCP Parameter Set Handling OCN MODIFY SCCP SUBSYSTEM PARAMETERSET

Id:0900d805804f02e6

/*** DISK UPDATING FAILED ***/

The disk updating failed.

/*** DISTRIBUTION AND DISK UPDATING FAILED ***/

The data distribution and the disk updating failed.

/*** DISTRIBUTION ERROR ***/

The data distribution failed.

/*** FILE UPDATED ONLY IN ACTIVE CM (CAC) ***/

The files have been updated only in the active CM or CAC.

/*** INCORRECT MESSAGE ***/

The message received from the SCXADM is incorrect.

/*** SEMIPERMANENT FILE UPDATING FAILED ***/

The updating of the semipermanent files failed.

/*** TIME LIMIT EXCEEDED ***/

No reply is received within the time limit to the parameter set data modification or inquiry message sent by the SC4HAN.

Page 28: OC - SCCP Parameter Set Handling Nokia

28 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805802911ff

OCR CHANGE SCCP PARAMETER SET NAME

OCR CHANGE SCCP PARAMETER SET NAME

Function With this command you can change the name of an existing SCCP signalling point parameter set or an existing SCCP subsystem parameter set.

Parameters parameter set type: parameter set number, parameter set name: new parameter set name;

SyntaxOCR: <parameter set type>:

(<parameter set number> | <parameter set name>):

<new parameter set name> ;

Parameter explana-tions

parameter set type

Use this parameter to indicate whether you want to change the name of an SCCP sig-nalling point parameter set or an SCCP subsystem parameter set:

0 SCCP signalling point parameter set

1 SCCP subsystem parameter set.

This parameter is compulsory.

parameter set number

The number of the parameter set you wish to rename. The parameter set number is an alternative to the parameter set name.

parameter set name

The parameter set name you wish to change. The parameter set name is an alternative to the parameter set number. The number and the name cannot be given simultane-ously.

new parameter set name

The new name of the parameter set. This parameter is compulsory.

Examples 1. To change the name of signalling point parameter set 10 to ANSI, give the following command:

OCR:0:10:ANSI;

Execution printouts The execution printout of the example 1 command is as follows:

CHANGING SCCP SIGNALLING POINT PARAMETER SET NAMESET NUMBER: 00010=================OLD NAME NEW NAME--------- ---------ITU-T ANSI

COMMAND EXECUTED

Page 29: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

29

OC - SCCP Parameter Set Handling OCR CHANGE SCCP PARAMETER SET NAME

Id:0900d805802911ff

Semantic error messages

/*** SUBSYSTEM PARAMETER SET DOES NOT EXIST ***/

The parameter set you wish to modify does not exist.

In addition, the general semantic error messages of MML commands are used.

Execution error messages

During the command execution, minor and major errors may occur, preventing the exe-cution of the command.

Minor errors are indicated with the text COMMAND EXECUTION FAILED. If the require-ments for the command execution are not met, a minor error is concerned. A minor error may be detected, for example, when the system reads the files and checks the validity of the data. In these cases, file modifications have not occurred.

Major errors are indicated with the text COMMAND EXECUTION ABORTED. If the task defined in the command is partly completed before the interruption, a major error is con-cerned. In these cases, file modifications have possibly been already completed, and the files may contain indefinable data.

Minor errors include the following cases:

/*** ACTIVE UNIT STATE INCORRECT ***/

The state of the active unit is not WO-EX.

/*** ILLEGAL MESSAGE LENGTH BETWEEN SC4HAN AND SCXADM ***/

The length of the message sent by the SCCP Parameter Set Handling MML (SC4HAN) to the SCXADM is incorrect.

/*** ILLEGAL PARAMETER ***/

The SCXADM does not accept the value of a parameter.

/*** PASSIVE UNIT STATE INCORRECT ***/

The passive unit is in an indefinable state or in working state SP-RE.

/*** SEMIPERMANENT FILE UPDATING BUSY ***/

The updating of the semipermanent files is in progress.

/*** SUBSYSTEM ACTIVATION NOT DENIED ***/

The subsystem was not set to the UA-INU state before the modification of its parameter set was attempted.

/*** SWITCHOVER ***/

A switchover is in progress.

/*** SWITCHOVER PREPARING ***/

A switchover preparation is in progress.

/*** SIGNALLING POINT PARAMETER SET DOES NOT EXIST ***/

The signalling point parameter set does not exist.

/*** SUBSYSTEM PARAMETER SET DOES NOT EXIST ***/

The subsystem parameter set does not exist.

/*** INCORRECT PARAMETER SET NAME ***/

The parameter set name is incorrect.

/*** PARAMETER SET NAME ALREADY EXISTS ***/

The parameter set name already exists.

Major errors include the following cases:

Page 30: OC - SCCP Parameter Set Handling Nokia

30 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805802911ff

OCR CHANGE SCCP PARAMETER SET NAME

/*** COMMUNICATION ERROR BETWEEN ACTIVE AND PASSIVESCXADM ***/

The communication between the active and passive SCXADMs failed.

/*** CONFLICT BETWEEN ACTIVE AND PASSIVE CM (CAC)FILES ***/

The data of the active CM or CAC file contradicts that of the passive CM or CAC file.

/*** DISK UPDATING FAILED ***/

The disk updating failed.

/*** DISTRIBUTION AND DISK UPDATING FAILED ***/

The data distribution and the disk updating failed.

/*** DISTRIBUTION ERROR ***/

The data distribution failed.

/*** FILE UPDATED ONLY IN ACTIVE CM (CAC) ***/

The files have been updated only in the active CM or CAC.

/*** INCORRECT MESSAGE ***/

The message received from the SCXADM is incorrect.

/*** SEMIPERMANENT FILE UPDATING FAILED ***/

The updating of the semipermanent files failed.

/*** TIME LIMIT EXCEEDED ***/

No reply is received within the time limit to the parameter set data modification or inquiry message sent by the SC4HAN.

Page 31: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

31

OC - SCCP Parameter Set Handling OCD DELETE SCCP SIGNALLING POINT PARAME-TER SET

Id:0900d805803a63d0

OCD DELETE SCCP SIGNALLING POINT PARAMETER SET

Function With this command you can delete an existing SCCP signalling point parameter set.

Parameters signalling point parameter set number, signalling point parameter set name;

Syntax OCD: <signalling point parameter set number>, <signalling point parameter set name> ;

Parameter explana-tions

signalling point parameter set number

The number of the signalling point parameter set you wish to delete. This parameter is compulsory.

signalling point parameter set name

The name of the signalling point parameter set you wish to delete. This parameter is compulsory.

Examples 1. To delete the data on parameter set number 10, named CCITT, give the following command:

OCD:10,CCITT;

Execution printouts The execution printout of the example 1 command is as follows:

DELETING SCCP SIGNALLING POINT PARAMETER SETDATA OF DELETED SCCP SIGNALLING POINT PARAMETER SET

SET NUMBER: 00010 SET NAME: CCITT========================================================================NO: NAME VALUE UNIT--- ---- --------------------------- ------ 1 Q714_T_CONN_EST 90 1 S 2 Q714_T_IAS 90 1 S 3 Q714_T_IAR 270 1 S 4 Q714_T_REL 150 0.1 S 5 Q714_T_INT 60 1 S 6 Q714_T_RES 15 1 S 7 Q714_T_REP_REL 100 0.1 S 8 Q714_T_STAT_1ST 100 0.1 S 9 Q714_T_STAT_INC 300 0.1 S 10 Q714_T_STAT_MAX 9000 0.1 S 11 A_INTERFACE NO - 12 WHITE_BOOK_MGMT_USED NO - 13 SS_MANAGEMENT_USED YES - 14 XUDT_USED NO - 15 UDT_DENIED NO - 16 SEG_X_THRES 272 OCTETS 17 SEG_Y_THRES 272 OCTETS 18 TCAP_LOAD_SHARING_USED NO - 19 ADD_DPC_IF_RI_SSN NO - 20 ADD_GT_IF_RI_SSN NO - 21 ADD_DPC_IF_RI_GT NO -

Page 32: OC - SCCP Parameter Set Handling Nokia

32 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805803a63d0

OCD DELETE SCCP SIGNALLING POINT PARAME-TER SET

22 ANALYSE_ROOT_OF_CALLING_GT NO - 23 ALLOWED_GTI_VALUES 1-4 - 24 SSA_FILTER_TIMER 10 0.1 S 25 SSP_FILTER_TIMER 10 0.1 S 26 LUDT_USED NO - 27 CO_SEGM_USED NO - 28 GT_ADDR_FIXED_LEN NO -

COMMAND EXECUTED

Semantic error messages

/*** SIGNALLING POINT PARAMETER SET DOES NOT EXIST ***/

The parameter set you wish to delete does not exist.

In addition, the general semantic error messages of MML commands are used.

Execution error messages

Minor errors are indicated with the text COMMAND EXECUTION FAILED. If the require-ments for the command execution are not met, a minor error is concerned. A minor error may be detected, for example, when the system reads the files and checks the validity of the data. In these cases, file modifications have not occurred.

Major errors are indicated with the text COMMAND EXECUTION ABORTED. If the task defined in the command is partly completed before the interruption, a major error is con-cerned. In these cases, file modifications have possibly been already completed, and the files may contain indefinable data.

Minor errors include the following cases:

/*** ACTIVE UNIT STATE INCORRECT ***/

The state of the active unit is not WO-EX.

/*** ILLEGAL MESSAGE LENGTH BETWEEN SC4HAN AND SCXADM ***/

The length of the message sent by the SCCP Parameter Set Handling MML (SC4HAN) to the SCXADM is incorrect.

/*** ILLEGAL PARAMETER ***/

The SCXADM does not accept the value of a parameter.

/*** PASSIVE UNIT STATE INCORRECT ***/

The passive unit is in an indefinable state or in working state SP-RE.

/*** SEMIPERMANENT FILE UPDATING BUSY ***/

The updating of the semipermanent files is in progress.

/*** SIGNALLING POINT PARAMETER SET IN USE ***/

The parameter set is in use at the signalling point.

/*** SWITCHOVER ***/

A switchover is in progress.

/*** SWITCHOVER PREPARING ***/

A switchover preparation is in progress.

/*** SIGNALLING POINT PARAMETER SET DOES NOT EXIST ***/

The signalling point parameter set does not exist.

/*** INCORRECT PARAMETER SET NAME ***/

The parameter set name is incorrect.

Page 33: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

33

OC - SCCP Parameter Set Handling OCD DELETE SCCP SIGNALLING POINT PARAME-TER SET

Id:0900d805803a63d0

Major errors include the following cases:

/*** COMMUNICATION ERROR BETWEEN ACTIVE AND PASSIVESCXADM ***/

The communication between the active and passive SCXADMs failed.

/*** COMMUNICATION ERROR BETWEEN ACTIVE SCXADM AND ACTIVECCUPDA ***/

The communication between the active SCXADM and the active Updating Program Block for Common Channel Signalling Files (CCUPDA) failed.

/*** COMMUNICATION ERROR BETWEEN PASSIVE SCXADM ANDPASSIVE CCUPDA ***/

The communication between the passive SCXADM and the passive CCUPDA failed.

/*** CONFLICT BETWEEN ACTIVE AND PASSIVE CM (CAC)FILES ***/

The data of the active CM or CAC file contradicts that of the passive CM or CAC file.

/*** DISK UPDATING FAILED ***/

The disk updating failed.

/*** DISTRIBUTION AND DISK UPDATING FAILED ***/

The data distribution and the disk updating failed.

/*** DISTRIBUTION ERROR ***/

The data distribution failed.

/*** FILE UPDATED ONLY IN ACTIVE CM (CAC) ***/

The files have been updated only in the active CM or CAC.

/*** INCORRECT MESSAGE ***/

The message received from the SCXADM is incorrect.

/*** SEMIPERMANENT FILE UPDATING FAILED ***/

The updating of the semipermanent files failed.

/*** TIME LIMIT EXCEEDED ***/

No reply is received within the time limit to the parameter set deletion message sent by the SC4HAN.

Page 34: OC - SCCP Parameter Set Handling Nokia

34 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805804e5f20

OCK DELETE SCCP SUBSYSTEM PARAMETER SET

OCK DELETE SCCP SUBSYSTEM PARAME-TER SET

Function With this command you can delete an existing SCCP subsystem parameter set.

Parameters subsystem parameter set number, subsystem parameter set name;

SyntaxOCK: <subsystem parameter set number>,

<subsystem parameter set name>;

Parameter explana-tions

subsystem parameter set number

The number of the subsystem parameter set you wish to delete. This parameter is com-pulsory.

subsystem parameter set name

The name of the subsystem parameter set you wish to delete. This parameter is com-pulsory.

Examples 1. To delete the data on parameter set number 11, named CCITT, give the following command:

OCK:11,CCITT;

Execution printouts The execution printout of the example 1 command is as follows:

DELETING SCCP SUBSYSTEM PARAMETER SETDATA OF DELETED SCCP SUBSYSTEM PARAMETER SET

SET NUMBER: 00011 SET NAME: CCITT==========================================NO: NAME VALUE UNIT--- ---- ----- ------ 1 Q714_T_COORD_CHG 90 1 S 2 Q714_T_IGN_SST 60 1 S 3 A_INTERF_APPLIC NO - 4 A_INTERF_ERR_IGNORED NO - 5 TRANSLATION_SELECTION SCCP - 6 CALLING_ADDR_MODIFICATION NO - 7 CSCC_ALLOWED_OUT NO - 8 CSCC_ALLOWED_IN NO - 9 TRANSLATE_AT_DPC_IF_DPC_SSN_GT YES - 10 TC_TRANSACTION_IDS_THRESHOLD 75 PERCENTS 11 SEND_CALLING_SSN_IF_RI_SSN YES - 12 SEND_CALLING_SPC_SSN_IF_RI_GT YES - 13 KEEP_CLD_GT_IF_RI_SSN NO - 14 IMMEDIATE_STATE_INFO NO - 15 TC_PROTOCOL_VERS_EXCLUDED NO - 16 GT_RES_SPEC_HDL_RI_SSN NO -

COMMAND EXECUTED

Page 35: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

35

OC - SCCP Parameter Set Handling OCK DELETE SCCP SUBSYSTEM PARAMETERSET

Id:0900d805804e5f20

Semantic error messages

/*** SUBSYSTEM PARAMETER SET DOES NOT EXIST ***/

The parameter set you wish to delete does not exist.

In addition, the general semantic error messages of MML commands are used.

Execution error messages

During the command execution, minor and major errors may occur, preventing the exe-cution of the command.

Minor errors are indicated with the text COMMAND EXECUTION FAILED. If the require-ments for the command execution are not met, a minor error is concerned. A minor error may be detected, for example, when the system reads the files and checks the validity of the data. In these cases, file modifications have not occurred.

Major errors are indicated with the text COMMAND EXECUTION ABORTED. If the task defined in the command is partly completed before the interruption, a major error is con-cerned. In these cases, file modifications have possibly been already completed, and the files may contain indefinable data.

Minor errors include the following cases:

/*** ACTIVE UNIT STATE INCORRECT ***/

The state of the active unit is not WO-EX.

/*** ILLEGAL MESSAGE LENGTH BETWEEN SC4HAN AND SCXADM ***/

The length of the message sent by the SCCP Parameter Set Handling MML (SC4HAN) to the SCXADM is incorrect.

/*** ILLEGAL PARAMETER ***/

The SCXADM does not accept the value of a parameter.

/*** PASSIVE UNIT STATE INCORRECT ***/

The passive unit is in an indefinable state or in working state SP-RE.

/*** SEMIPERMANENT FILE UPDATING BUSY ***/

The updating of the semipermanent files is in progress.

/*** SUBSYSTEM PARAMETER SET IN USE ***/

The parameter set is in use in the subsystem.

/*** SWITCHOVER ***/

A switchover is in progress.

/*** SWITCHOVER PREPARING ***/

A switchover preparation is in progress.

/*** SUBSYSTEM PARAMETER SET DOES NOT EXIST ***/

The subsystem parameter set does not exist.

/*** INCORRECT PARAMETER SET NAME ***/

The parameter set name is incorrect.

Major errors include the following cases:

/*** COMMUNICATION ERROR BETWEEN ACTIVE AND PASSIVESCXADM ***/

The communication between the active and passive SCXADMs failed.

/*** CONFLICT BETWEEN ACTIVE AND PASSIVE CM (CAC)FILES ***/

Page 36: OC - SCCP Parameter Set Handling Nokia

36 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805804e5f20

OCK DELETE SCCP SUBSYSTEM PARAMETER SET

The data of the active CM or CAC file contradicts that of the passive CM or CAC file.

/*** DISK UPDATING FAILED ***/

The disk updating failed.

/*** DISTRIBUTION AND DISK UPDATING FAILED ***/

The data distribution and the disk updating failed.

/*** DISTRIBUTION ERROR ***/

The data distribution failed.

/*** FILE UPDATED ONLY IN ACTIVE CM (CAC) ***/

The files have been updated only in the active CM or CAC.

/*** INCORRECT MESSAGE ***/

The message received from the SCXADM is incorrect.

/*** SEMIPERMANENT FILE UPDATING FAILED ***/

The updating of the semipermanent files failed.

/*** TIME LIMIT EXCEEDED ***/

No reply is received within the time limit to the parameter set deletion message sent by the SC4HAN.

Page 37: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

37

OC - SCCP Parameter Set Handling OCI INTERROGATE SCCP SIGNALLING POINT PA-RAMETER SETS

Id:0900d805802ed90a

OCI INTERROGATE SCCP SIGNALLING POINT PARAMETER SETS

Function With this command you can interrogate the data on one or more SCCP signalling point parameter sets.

Parameters signalling point parameter set numbers, signalling point parameter set name;

SyntaxOCI: [ [<signalling point parameter numbers>... |

<all parameter sets> def] |

<signalling point parameter set name>; ] ;

Parameter explana-tions

signalling point parameter set numbers

If you wish to interrogate the data on all existing SCCP signalling point parameter sets, do not enter anything, as the default value is all parameter sets. The characters & and && are allowed. The parameter set number is an alternative to the parameter set name.

signalling point parameter set name

The name of the signalling point parameter set you wish to interrogate. The parameter set name is an alternative to the parameter set number. You cannot give the name and the number simultaneously.

Examples 1. To interrogate the data on parameter set 10, give the following command:

OCI:10;

Execution printouts The execution printout of the example 1 command is as follows:

INTERROGATING SCCP SIGNALLING POINT PARAMETER SETSSET NUMBER: 00010 SET NAME: CCITT========================================================================NO: NAME VALUE UNIT--- ---- --------------------------- ------ 1 Q714_T_CONN_EST 90 1 S 2 Q714_T_IAS 90 1 S 3 Q714_T_IAR 270 1 S 4 Q714_T_REL 150 0.1 S 5 Q714_T_INT 60 1 S 6 Q714_T_RES 15 1 S 7 Q714_T_REP_REL 100 0.1 S 8 Q714_T_STAT_1ST 100 0.1 S 9 Q714_T_STAT_INC 300 0.1 S 10 Q714_T_STAT_MAX 9000 0.1 S 11 A_INTERFACE YES - 12 WHITE_BOOK_MGMT_USED NO - 13 SS_MANAGEMENT_USED YES - 14 XUDT_USED NO - 15 UDT_DENIED NO - 16 SEG_X_THRES 272 OCTETS

Page 38: OC - SCCP Parameter Set Handling Nokia

38 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805802ed90a

OCI INTERROGATE SCCP SIGNALLING POINT PA-RAMETER SETS

17 SEG_Y_THRES 272 OCTETS 18 TCAP_LOAD_SHARING_USED NO - 19 ADD_DPC_IF_RI_SSN NO - 20 ADD_GT_IF_RI_SSN NO - 21 ADD_DPC_IF_RI_GT NO - 22 ANALYSE_ROOT_OF_CALLING_GT NO - 23 ALLOWED_GTI_VALUES 1-4,5,6,7,8,9,10,11, - 12,13,14,15 - 24 SSA_FILTER_TIMER 10 0.1 S 25 SSP_FILTER_TIMER 10 0.1 S 26 LUDT_USED NO - 27 CO_SEGM_USED NO - 28 GT_ADDR_FIXED_LEN NO -

COMMAND EXECUTED

The following messages may be output together with the data on the parameter sets:

SIGNALLING POINT PARAMETER SET DOES NOT EXIST

The command includes a parameter set that does not exist in the SCCP Signalling Point Parameter File.

NO PARAMETER SET FOUND

None of the interrogated parameter sets exist in the system.

Semantic error messages

If an error occurs, the general semantic error messages of MML commands are output.

Execution error messages

During the command execution, minor errors may occur, preventing the command exe-cution. They are indicated with the text COMMAND EXECUTION FAILED. Such errors may be detected, for example, when the system reads the files and checks the validity of the data.

Minor errors include the following cases:

/*** ILLEGAL MESSAGE LENGTH BETWEEN SC4HAN AND SCXADM ***/

The length of the message sent by the SCCP Parameter Set Handling MML (SC4HAN) to the SCXADM is incorrect.

/*** INCORRECT MESSAGE ***/

The message received from the SCXADM is incorrect.

/*** TIME LIMIT EXCEEDED ***/

No reply is received within the time limit to the interrogation message sent by the SC4HAN.

/*** SIGNALLING POINT PARAMETER SET DOES NOT EXIST ***/

The signalling point parameter set does not exist.

/*** INCORRECT PARAMETER SET NAME ***/

The name of the parameter set is incorrect.

Page 39: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

39

OC - SCCP Parameter Set Handling OCJ INTERROGATE SCCP SUBSYSTEM PARAME-TER SETS

Id:0900d805804f17a5

OCJ INTERROGATE SCCP SUBSYSTEM PARAMETER SETS

Function With this command you can interrogate the data on one or more SCCP subsystem parameter sets.

Parameters subsystem parameter set numbers, subsystem parameter set name;

Syntax

OCJ: [ [<subsystem para set numbers>... | <all parameter sets>def ] |

<subsystem parameter set name>; ] ;

Parameter explana-tions

subsystem parameter set numbers

If you wish to interrogate the data on all existing SCCP subsystem parameter sets, do not enter anything, as the default value is all parameter sets. The characters & and && are allowed. The parameter set number is an alternative to the set name.

subsystem parameter set name

The name of the subsystem parameter set you wish to interrogate. The parameter set name is an alternative to the parameter set number. The number and the name cannot be given simultaneously.

Examples 1. To interrogate the data on parameter set 10, give the following command:

OCJ:10;

Execution printouts The execution printout of the example 1 command is as follows:

INTERROGATING SCCP SUBSYSTEM PARAMETER SETS

SET NUMBER: 00010 SET NAME: CCITT==========================================NO: NAME VALUE UNIT--- ---- ----- ------ 1 Q714_T_COORD_CHG 90 1 S 2 Q714_T_IGN_SST 60 1 S 3 A_INTERF_APPLIC YES - 4 A_INTERF_ERR_IGNORED YES - 5 TRANSLATION_SELECTION SCCP - 6 CALLING_ADDR_MODIFICATION NO - 7 CSCC_ALLOWED_OUT NO - 8 CSCC_ALLOWED_IN NO - 9 TRANSLATE_AT_DPC_IF_DPC_SSN_GT YES - 10 TC_TRANSACTION_IDS_THRESHOLD 75 PERCENTS 11 SEND_CALLING_SSN_IF_RI_SSN YES - 12 SEND_CALLING_SPC_SSN_IF_RI_GT YES - 13 KEEP_CLD_GT_IF_RI_SSN NO - 14 IMMEDIATE_STATE_INFO NO - 15 TC_PROTOCOL_VERS_EXCLUDED NO - 16 GT_RES_SPEC_HDL_RI_SSN NO -

Page 40: OC - SCCP Parameter Set Handling Nokia

40 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d805804f17a5

OCJ INTERROGATE SCCP SUBSYSTEM PARAME-TER SETS

COMMAND EXECUTED

The following messages may be output together with the data on the parameter sets:

SUBSYSTEM PARAMETER SET DOES NOT EXIST

The command includes a parameter set that does not exist in the SCCP Subsystem Parameter File.

NO PARAMETER SET FOUND

None of the interrogated parameter sets exist in the system.

Semantic error messages

If an error occurs, the general semantic error messages of MML commands are output.

Execution error messages

During the command execution, minor errors may occur, preventing the command exe-cution. They are indicated with the text COMMAND EXECUTION FAILED. Such errors may be detected, for example, when the system reads the files and checks the validity of the data.

Minor errors include the following cases:

/*** ILLEGAL MESSAGE LENGTH BETWEEN SC4HAN AND SCXADM ***/

The length of the message sent by the SCCP Parameter Set Handling MML (SC4HAN) to the SCXADM is incorrect.

/*** INCORRECT MESSAGE ***/

The message received from the SCXADM is incorrect.

/*** TIME LIMIT EXCEEDED ***/

No reply is received within the time limit to the interrogation message sent by the SC4HAN.

/*** SUBSYSTEM PARAMETER SET DOES NOT EXIST ***/

The subsystem parameter set does not exist.

/*** INCORRECT PARAMETER SET NAME ***/

The name of the parameter set is incorrect.

Page 41: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

41

OC - SCCP Parameter Set Handling OCH HELP TEXT FOR SCCP SIGNALLING POINTPARAMETERS

Id:0900d80580446d66

OCH HELP TEXT FOR SCCP SIGNALLING POINT PARAMETERS

Function With this command you can output the help texts for one or more parameters in the SCCP signalling point parameter set.

Parameters parameter number;

SyntaxOCH: [<parameter number>... | <all parameters>def ] ;

Parameter explana-tions

parameter number

If you wish to output the help text for all the parameters, do not enter anything, as the default value is all parameters. The characters & and && are allowed.

Examples 1. To interrogate the recommended values, value limits, and help texts for parameters 1 to 10, give the following command:

OCH:1&&10;

Execution printouts When interrogating the help texts for parameters 1, 10, and 11, the execution printout of the command

OCH:1&10&11;

is as follows:

HELP TEXT FOR SCCP SIGNALLING POINT PARAMETERS

Q714 ARE VALUES OF TIMER OF CCITT RECOMMENDATION Q714

PARAMETER NUMBER: 001===================== CONNECTION ESTABLISHMENT TIMER, TIME UNIT IS 1 S

NAME ABBREVIATION REC VALUE LOW VALUE HIGH VALUE----------------- --------- --------- ----------Q714_T_CONN_EST 90 30 240

PARAMETER NUMBER: 010===================== MAXIMUM VALUE OF SUBSYSTEM STATUS TEST, SEND INTERVAL, TIME UNIT IS 100 MS

NAME ABBREVIATION REC VALUE LOW VALUE HIGH VALUE----------------- --------- --------- ----------Q714_T_STAT_INF_MAX 9000 600 12000

PARAMETER NUMBER: 011===================== INTERFACE TO SIGNALLING POINT IS A INTERFACE

NAME ABBREVIATION DEFAULT VALUES----------------- -------- --------

Page 42: OC - SCCP Parameter Set Handling Nokia

42 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d80580446d66

OCH HELP TEXT FOR SCCP SIGNALLING POINT PARAMETERS

A_INTERFACE NO NO/YES

COMMAND EXECUTED

Semantic error messages

If an error occurs, the general semantic error messages of MML commands are output.

Execution error messages

During the command execution, minor errors may occur, preventing the command exe-cution. They are indicated with the text COMMAND EXECUTION FAILED. Such errors may be detected, for example, when the system reads the files and checks the validity of the data.

Minor errors include the following cases:

/*** ILLEGAL MESSAGE LENGTH BETWEEN SC4HAN AND SCXADM ***/

The length of the message sent by the SCCP Parameter Set Handling MML (SC4HAN) to the SCXADM is incorrect.

/*** INCORRECT MESSAGE ***/

The message received from the SCXADM is incorrect.

/*** TIME LIMIT EXCEEDED ***/

No reply is received within the time limit to the parameter data interrogation message sent by the SC4HAN.

Page 43: OC - SCCP Parameter Set Handling Nokia

DN986488Issue 10-0

43

OC - SCCP Parameter Set Handling OCL HELP TEXT FOR SCCP SUBSYSTEM PARAM-ETERS

Id:0900d80580296165

OCL HELP TEXT FOR SCCP SUBSYSTEM PARAMETERS

Function With this command you can output the help texts for one or more parameters in the SCCP subsystem parameter set.

Parameters parameter number;

SyntaxOCL: [<parameter number>... | <all parameters> def] ;

Parameter explana-tions

parameter number

If you wish to output the help texts for all the parameters in the SCCP subsystems, do not enter anything, as the default value is all parameters. The characters & and && are allowed.

Examples 1. To interrogate the recommended values, value limits, and help texts for parameters 1 to 3, give the following command:

OCL:1&&3;

Execution printouts When interrogating the help texts for parameters 1 to 4 and 7, the execution printout of the command

OCL:1&&4&7;

is as follows:

HELP TEXT FOR SCCP SUBSYSTEM PARAMETERS

Q714 ARE VALUES OF TIMER OF CCITT RECOMMENDATION Q714

PARAMETER NUMBER: 001===================== WAITING TO SUBSYSTEM OUT OF SERVICE GRANT, TIME UNIT IS 1 S

NAME ABBREVIATION REC VALUE LOW VALUE HIGH VALUE----------------- --------- --------- ----------Q714_T_COORD_CHG 90 30 240

PARAMETER NUMBER: 002===================== SUBSYSTEM STATUS TEST IGNORING TIME, TIME UNIT IS 1 S

NAME ABBREVIATION REC VALUE LOW VALUE HIGH VALUE----------------- --------- --------- ----------Q714_T_IGN_SST 60 30 300

PARAMETER NUMBER: 003===================== A INTERFACE TYPE OF SP APPLICABLE TO SS

NAME ABBREVIATION DEFAULT VALUES

Page 44: OC - SCCP Parameter Set Handling Nokia

44 DN986488Issue 10-0

OC - SCCP Parameter Set Handling

Id:0900d80580296165

OCL HELP TEXT FOR SCCP SUBSYSTEM PARAM-ETERS

----------------- -------- --------A_INTERF_APPLIC NO NO/YES

PARAMETER NUMBER: 004===================== ERR MESSAGE FROM A INTERFACE IS IGNORED WITH SS

NAME ABBREVIATION DEFAULT VALUES----------------- -------- --------A_INTERF_ERR_IGNORED NO NO/YESPARAMETER NUMBER: 007===================== INDICATES WHETHER SUBSYSTEM IS ALLOWED TO REQUEST COORDINATED STATE CHANGE

NAME ABBREVIATION DEFAULT VALUES----------------- -------- --------CSCC_ALLOWED_OUT NO NO/YES

COMMAND EXECUTED

Semantic error messages

If an error occurs, the general semantic error messages of MML commands are output.

Execution error messages

During the command execution, minor errors may occur, preventing the command exe-cution. They are indicated with the text COMMAND EXECUTION FAILED. Such errors may be detected, for example, when the system reads the files and checks the validity of the data.

Minor errors include the following cases:

/*** ILLEGAL MESSAGE LENGTH BETWEEN SC4HAN AND SCXADM ***/

The length of the message sent by the SCCP Parameter Set Handling MML (SC4HAN) to the SCXADM is incorrect.

/*** INCORRECT MESSAGE ***/

The message received from the SCXADM is incorrect.

/*** TIME LIMIT EXCEEDED ***/

No reply is received within the time limit to the parameter data interrogation message sent by the SC4HAN.