NX Series(NX700/NX70/NX7)

PLC with Advanced Performance in Compact Size

Page 2: Oemax Nx Plc

Advanced Performance in Compact Size, OEMax PLC Series

NX Series, a new family of OEMax PLC, is designed to international

standards so that it can be used globally in a wide variety of markets.

Even diverse requirements of customers can be configured efficiently. NX

PLC can be used for a new facility or system or to dramatically upgrade an

existing one. All of the NX7, NX70, NX700 Series have a full lineup of

diverse modules so that many control system configurations, from

miniature to large size, are possible.

Contents■Characteristics of NX Series

■System of PLC Type

■Network Configuration Chart

■Basic Configuration of NX700

■Basic Configuration of NX70

■Special Modules of NX700/NX70

Analog Module

Special Module

Communication and Network Module

Field bus

■Configuration Chart of NX7

■Program Device and Software

■External Dimension

■Product Catalog

3

4

6

10

22

35

36

40

48

64

67

72

79

84

2 I OEMax NX Series

Page 3: Oemax Nx Plc

NX SeriesNX700 / NX70 / NX7 Series

NX700 Series with Advanced and Integrated Functions

NX700 Series is a new family with dramatically improved functionality, designed for convenience and efficiency in orderto meet and cope with next generation control devices. -Control Points: Local 1600 points (2048~8192 points including REMOTE)) -Diverse CPU Line-up: CPU700P, CPU700, CPU 750A/B/C/D, etc. -Memory Capacity: 16K ~ 120K -Computing Speed: 0.03us ~ 0.4 us -Internal Points: 2048 ~8192 points -Data Memory: 2048 ~ 10,240 words

NX70 Series with Expanded Reliability and Extended Configuration

NX70 Series has a similar functions to NX700 but in a more compact size. It is designed to be noise immune anddurable for operation in noisy and hard environments. This results in maximum reliability for customers. New productsare available such as communications modules and high performance specialty modules to accommodate diversesystem configurations.- Control Points: External I/O 384 points- Type of Bases: 2,3,5,6,8,10,12 Slot - Memory Capacity: 9.6K ~ 32K Words - Computing Speed: 0.2 us ~ 0.4 us - Internal Points: 2048 ~ 8192 points- Data Memory: 2048 ~ 6000 Words

NX7 Series with Compact Size and Diverse Functions

NX7 Series is a new product which enables economical system configurations with compact size and integrated specialfunctions.- Control Points: External I/O 28~104 point - Memory Capacity: 9K Words, Communication Port: RS232C/485 dual use 2 Ports. - Special Functions: Built-in Functions such as: High Speed Counter, Pulse Output, Pulse Catch, PID, Clock Function,

Backup Memory, etc.

OEMAX NX Series I 3

Page 4: Oemax Nx Plc

The OEMax PLC lineup which ranges in size from the

applications. Because of it’s programming (NX-Series,

customers an opportunity to choose the ideal product

Large Scale Control

Countermeasureto CIM

Medium Scale Control

Network Diversification

Alternative RelaySequence

Small Scale Control

Network Module & Function�EtherNet (TCP/IP, UDP/IP)

�MW- LINK

�W- LINK

�REMOTE I/O (4 ea, 32 stations)

�DeviceNet (64 node)

�Single Unit Block Type Micro-PLC (Compact Size)

�8 Basic Types (4 types with 28 points, 4 types with 48 points)

2 Extension I/O modules (2 Types with 28 points)

�Extendable up to maximum 104 points

�Communication Function: 2 Port(RS232C/ RS485)

�High speed counter and Pulse Output function

�User Software: WinGPC S/W

Structure of OEMax Types

NX7 PLC Single Unit Type NX70 PLC

NX70

NX7-28

�Single Unit Type with 28points�Communication 2 port �9k STEP (Expandable)

NX7-48

�Single Unit Type with 48points�Communication 2 port �9k STEP (Expandable)

NX7 Series

4 I OEMax NX Series

CPU70

�384 points�0.5us �16k Step �Comment

Memory

CPU70p1

�384 points �0.2us �9.6K words

Page 5: Oemax Nx Plc

small NX7 to the medium-size NX700 is scalable in order to be applicable to a wide range of

NX-plus Series), module, and network diversity and compatibility, OEMax PLC provides

for their application.

�Modular small sized PLC (small size)

�CPU Module 4 Types(High Performance: CPU750,

CPU70p2 Standard: CPU70, CPU70p1)

�Backplane: 2, 3, 5, 6, 8, 10, 12 slots

�Diverse I/O Modules: High speed Counter (4CH), Pulse

Output(4CH), Communication Unit(CCU, SCU),

Network(MW-Link), etc.

�Maximum 384 points Digital I/O Control

�Medium size PLC functions despite small size

�Modular Medium sized PLC

�6 Types of CPU Modules

-High Performance: CPU750C, CPU750D,

-Standard : CPU750A, CPU750B,

-Economical: CPU700, CPU700p)

�Compatible with Basic/ Expanded Backplane

�Backplane 3, 5, 8, 10, 12 slots

�PID Auto Tuning(NX-CPU750), I/O(13 types),

Special Modules, etc. (30 types)

�Local maximum 1600 points (Remote I/O - 8,192 points)

Building Block Type NX700 PLC Building Block Type

Series

NX700 Series

OEMAX NX Series I 5

CPU750

�384 points�0.35us �32K Step �Comment Memory �PID Auto Tuning, etc.

CPU750A

�2,048 points(Remote inclusive)

�0.35us �16K Step �PID Auto Tuning, etc.

CPU750B

�2,048 points(Remote inclusive)

�0.35us �32K Step �Comment Memory

CPU750C

�8,192 points(Remote inclusive)

�0.03us(30ns) �60K Step �Comment Memory�PID Auto Tuning, etc.

CPU750D

�8,192 points(Remote inclusive)

�0.03us(30ns) �120K Step �Comment Memory�PID Auto Tuning, etc.

CPU700

�1,6 ,600 points�0.4us �16K Step �Comment Memory

CPU700p

�2,048 points(Remote inclusive) �0.2us �20K words �2Port

CPU70p2

�384 points �0.2us �20K words

Page 6: Oemax Nx Plc

A variety of OEMax PLC network options

low-cost serial networks to Ethernet for

A variety of OEMax PLC network options are

available to meet a wide variety of requirements

and environments, ranging from small low-cost

serial networks to Ethernet for large scale control

systems.

Specifics of OEMax PLC Network

�OEMax PLC Network enables to configure setting up of

diverse link systems to the environments.

�Enables simultaneous executions of Computer Link

and PLC Link so as to collect data from the Computer

or transmit to PLC without disconnection of

communication between PLCs.

�Enables to receive or transmit data by the Computer

from PLC so that process time for execution of

Computer can be utilized effectively.

�Enables the Remote Programming from PLC or

Computer so as to edit or monitor programmings from

other PLCs

�Enables mutual information exchanges from the

respective Link Network Systems as well as

communication interface regardless of OEMax PLC

types.

�Each Link Unit itself has Self Diagnosis Function(RAS)

so that there is no need of monitoring devices for Links

and thus economical.

Large Scale In

form

ation C

ontro

l Netw

ork

EtherNet

Multi Wire-Link Network

Wire-Link Network

Remote I/O System

EtherNetEtherNet

Network System, Each Type ofFacility Devices, BuildingManagement Systems,etc

Multi Drop wiring with

Twist Pair Cable

Multi Drop wiring with

Twist Pair Cable

Multi Drop wiring with

Twist Pair Cable

MW-Link Unit

NX700 Series

SLAVE Unit

NX700 Series

W-Link Master Unit

NX700 Series

MW-Link

NX700 Series

MW-Link

Remote I/O Main Station

OEMax PLC Network Configuration Diagram

NX70 Series

SLAVE Unit

6 I OEMax NX Series

MW-Link Unit

NX70 Series

Medium

Scale C

ontro

l Netw

ork

Sm

all Scale N

etwork

Page 7: Oemax Nx Plc

are available to meet a wide variety of requirements and environments, ranging from small

large scale control systems.

EtherNet

EtherNet Unit

NX700 Series

DeviceNet Network MW-Link Unit

NX700 Series

Scanner Card forComputer (PC) (ISA, PCI, PCMCIA)

Master Card for PLC Scanner Card (for NX700)

DeviceNet(Slave)

NX70 Series

Inverter

Terminal Type(20 pin)

Terminal Type(38 pin)

Connector Type(37 pin) Robot

W-Link Unit

NX70 Series

NX700 Series

MW-Link

NX700 Series

MW-Link

DeviceNet (Master)

DeviceNet (Slave)

EtherNet Network

Corresponds to TCP/IP and UDP/IP, and widely communicable with

computers and the like on the Network (LAN) through interface with 10BASE5

(for N700a), 100BASE-TX, 10BASE-T, 10BASE5 (for NX700) LAN.

★Corresponding PLC: N700a PLC, N700H PLC, NX700(CPU750) PLC

■Have functions like Computer Link, Data Transmission, Remote Programming

between other PLCs interfaced with EtherNet Network and computers Transmission Speed: 100M bit/s(NX700), 10M bit/s(N700a)

Maximum No. of NODEs: 100Node/ Segment, Transmission Method: Base Band

No. of Communication Connections: Maximum 8 Connections, Maximum

Distance between Nodes: 2500m~205m

Multi W-Link Network

Large capacity PLC Network System with Twisted-Pair Cable and

economical decentralized (distributed) control system can be

established. (MW-Link Unit)

★Corresponding PLC: NX700 PLC (CPU750), NX70 PLC (CPU750)

■Q’y of Data transmissible at a time is 1,020 words and PLC Link

function is 32 stations simultaneously (In addition, L, Ld capacity can

be widely increased)

■Distance of transmission can be extended up to 1,200m by speed alteration

Transmission Speed: 0.5MBps, 800m Number of Stations: 32 stations/ 1 layer

Layer: 2 Layers Transmission Line: Twisted-Pair Cable

W-Link Network

PLC Network with Twisted-Pair Cable, economical decentralized

control can be established.

★Corresponding PLC: Supports NX700, NX70 Series (Excluding NX-

CPU700, NX70-CPU70, NX70-CPU70p1)

■With Multi-Drop wiring of Twisted-Pair Cable, easily established and

high speed-long distance transmission can be achieved.

Transmission Speed: 0.5MBps, 800m Number of Stations: 32 stations/ 1 layer

Layer: 2 layers Transmission Line: Twisted-Pair Cable

Remote I/O System

System for controlling I/O and the like located at long distances and

dispersed areas.

★Corresponding PLC : Supports Master with NX700 type (excluding NX-CPU700)

Supports Slave with NX700, NX70 type

Transmission Line: Twisted-Pair Cable (700m), 2 line cable (400m)

Number of Stations:32 stations(Slave unit) /Master unit, 4 Master/ CPU unit

DeviceNet Network

As a DeviceNet product which is a Open Network, Device Level

function is standardized with the Open Architecture and mutually

interfaced with the products that has adopted DeviceNet Profile so as

to enable transmitting and /receiving data.

★Scanner(Master): N700 PLC, NX700 PLC, Computer Cards (PCI, ISA..)

■Slip Type, Micro size (104 x 43 x 52mm)

■Able to interface between different types of DeviceNet products

Transmission Speed: 0.5MBps No. of Nodes: 64 nodes/ Network

NETWORK Protocol: I/O Slave messaging( Group 2 only)

ODVA Approval: Granted Standard Test of DeviceNet Conformance

OEMaxNX Series I 7

W-Link Unit

NX70 Series

MW-Link Unit

NX70 Series

Page 8: Oemax Nx Plc
Page 9: Oemax Nx Plc

High Tech CPU (WinFPST adopted)

General Purpose CPU (WinFPST adopted)

General Purpose Plus CPU (WinGPC adopted)

NX

700 Series

*Refer to the attached ■CPU750A

■CPU750B

■CPU750C

■CPU750D

■CPU700

■CPU700P

OEMaxNX Series I 9

Page 10: Oemax Nx Plc

Basic Configuration of NX700

�3 Module Type (NX-BASE03) �5 Module Type (NX-BASE05)

�Basic configuration and Control I/O Point remain unchanged regardless of CPU Type.

(CPU Type : CPU750A, CPU750B, CPU750C, CPU750D, CPU700, CPU700p)

80 points: when configured with 16 points I/O320 points: when configured with 64 points I/O

�12 Module Type (NX-BASE12)

128 points: when configured with 16 points I/O512 points: when configured with 64 points I/O

160 points: when configured with 16 points I/O640 points: when configured with 64 points I/O

192 points: when configured with 16 points I/O768 points: when configured with 64 points I/O

■Building Block Method with Flexible Unit Combination�NX700 PLC has 5 types of motherboard and various kinds of I/O units can be freely mounted. (5 types of Motherboard: 3, 5, 8, 10, 12 Module Type) �I/O Module, Power Source Module, Special Module, and Motherboard are common regardless of CPU type. (6 types of CPU: CPU750A, CPU750B, CPU750C, CPU750D .CPU700, CPU700p)

■Display of Slot NumbersDisplay of slot numbers on the motherboard indicates the number of mountable I/O units and special modules. (ex. 5 slot typed NX-BASE05motherboard can mount up to 5 I/O units and special modules.)

(N. B.)

1)Electricity source unit is required at the additional

Motherboard.

2)CPU unit is disallowed to use at the additional motherboard.

3)One more slot can be used at the additional motherboard

than the motherboard of CPU. (I/O and special module can

be mounted at the place of CPU side slot)

■If used as an additional Motherboard

■Only one motherboard is allowed to add.

■Basic and additional motherboards can be used reciprocally without distinction.

Added Cable

N. B. Units not allowed to use at the added motherboard CPU unit, CCU unit, CCU+ unit, Remote Slave unit, MW-Link unit, EtherNet unit, DeviceNet Master unit

10 I OEMax NX Series

48 points: when configured with 16 points I/O192 points: when configured with 64 points I/O

�8 Module Type (NX-BASE08) �10 Module Type (NX-BASE10)

Basic Configuration and Control I/O Point

Page 11: Oemax Nx Plc

OEMaxNX Series I 11

■Configuration of units that can be mounted

×

×

×

×

×

×

×

×

×

×

×

■Restrictions according to the types of units

Type of Units

Mountable modules according to CPU Units

�NX-CPU700p (Plus Type)

�NX-CPU700

�NX-CPU750C �NX-CPU750D

�NX-CPU750A �NX-CPU750B

AdvancedPerformance CPU

AdvancedCPU

PrototypeCPU

Basic Unit Special Unit Network Unit

Motherboard (3, 5, 8, 10, 12 M

odule)

Electricity Source (Power supply) Unit

Input Unit

Output U

nit

A/D, D

/A, RTD, TC

Unit

High Speed C

ounter Unit (1, 2C

H)

High Perform

ance High Speed

Counter U

nit (4CH)

Pulse I/O U

nit (4CH)

SCU U

nit (2CH)

CCU U

nit (1CH) *1

CCU+

Unit (1C

H) *1

REMO

TE I/O SYSTEM

(M

ASTER / SLAVE Unit) *1

MW

-Link U

nit(W

, W2-

Mode) *1

EtherNet U

nit *1

DeviceN

et Master U

nit

Com

puter Software

WinFPSTS/W

WinGPC

Positioning Unit(1,2,3,4 axis)

(Open C

ollector & LineD

rive)

○ : Usable △ : Usable according to Version × : Unusable

Special Unit

�A/D, D/A, RTD, TC

�CCU, SCU unit

�Positioning (1, 2, 3, 4 axis)

(Open Collector & LineDrive)

�High Speed Counter (1/ 2CH)

�High Performance High

Speed Counter (4CH)

�Pulse Output unit (4CH)

�Remote I/O SYSTEM

�MW-LINK SYSTEM

�EtherNet SYSTEM

�DeviceNet SYSTEM

CPU Unit

�NX-CPU750A16k Step, 0.35μsCommunication port 2port

Electricity Source (Power) unit

�NX-POWER (AC110/220V)

5V 4A, 24V 0.5A

�NX-PWR220 (AC 220V) 5V 6A

�NX-PWRDC (DC 24V) 5V 5A

�NX-CPU750B32k Step, 0.35μs Comment MemoryCommunication Port 2port

�NX-CPU750C60k Step, 0.03μs Comment MemoryCommunication Port 2port

�NX-CPU750D120k Step, 0.03μs Comment MemoryCommunication Port 2port

�NX-CPU70016k Step, 0.4μsμs Comment MemoryCommunication Port 1port

�NX-CPU700p20k Step, 0.2μsCommunication Port 2port Use WinGPC S/W

Peripheral Device

�Computer Software

- WinFPST S/W(for CPU750, CPU700)

- WinGPC S/W(for CPU700p)

�Computer Interface Cable

- NX-CBLCPU02,05

Motherboard

�3 slot type

�5 slot type

�8slot type

�10slot type

�12 slot type

I/O unit

�16 point type

�32 point type

�64 point type

※Display of slot numbers indicates thenumber of I/O and special units mounted

※CPU module is not necessary whenmotherboard is used for extensionpurpose and thus one more slot can beused additionally

※1. Restrictions on mounting Link-system units

※Combined use for Basic/Additional setup

Note) NX-CPU700p type supports some special functions above OS version 2.0.

CCU unit

MW-Link unit (W-mode)

MW-Link unit (W2-mode)

EtherNet unit

Remote Master unit

CCU+ unit

Can be used up to 8 units including CCUunit, but only up to 2 ea for PLC link function

Can be used up to 5 units including CCUunit, but only up to 2 ea for PLC link function

Only 1 unit can be used Unable to use

Unable to use

Can be used

Unable to use

Can be used

Master 1 unit

Can be used up to 3 units(PLC link function is only upto 2 units)

Can be used up to 3 units

Master Function: 4 units/ 1 CPU, 32 Slave units/ 1 Master

Unable to use

Can be used up to 8 units

Kinds of Unit In case of CPU750A, CPU750B units In case of CPU750C, CPU750D units In case of CPU700 unit In case of CPU700p unit

Caution Commands and programming tools for CPU700p is different from those of CPU750 series

System Configuration

Page 12: Oemax Nx Plc

12 I OEMax NX Series

■Characteristics

High speed medium-large scaled PLC with Maximum Processing Speed 0.03us(30ns), Capacity of Program 16k~120k,

Sharing same Commands with N700_series and PID Auto Tuning Function and two communication ports mounted. In

addition, large scaled PLC function is compressed into compact size for easy use.

NX-CPU750B�32k STEP�0.35us�Clock Function�Comment Memory

NX-CPU750A�16k STEP�0.35us �Clock Function

COM Port

�16k STEP(Extended Memory)

�Comment Memory

�EPROM Socket

(Applicable only to CPU750A)

Memory unit (NX-MEM750A)

NX-CPU750C�60k STEP�0.03us (30ns)�Clock Function�Comment Memory

NX-CPU750D�120k STEP�0.03us (30ns)�Clock Function�Comment Memory Computer Computer

T/P

TOOL Port

0.35μs

0.93μs�

16k,32k step

2,048points

2,048points

4,048points

6,000words

30,717words

1,024points

128words

1,024points

1,024points

14words

Sequence command

Application command

Program capacity

I/P relay(X)

O/P relay(Y)

Internal relay(R)

Data register(DT)

File register(FL)

Link relay(L)

Link register(Ld)

Timer/ Counter(T/C)

Pulse relay(P)

Index register

Data C

apacity

Operation Command (per 1 command)

0.03μs

0.06μs�

60k,120kstep

8,192points

8,192points

14,192points

10,240words

32,765words

10,240points

8,448words

3,072points

1,024points

14words

0.4μs

Tens of μs�

16k step

2,048points

2,048points

1,568points

2,048words

22,525words

1,024points

128words

256points

N/ A

2words

NX700 PLC(CPU750A, B)Item

CPU TYPE NX700 PLC(CPU700)

NX700 PLC(CPU750C, D)

2. Scan time 1ms. (when preparing 20,000 Steps) Time for 1 scan was significantly reduced by adopting parallel system ofoperation process and communication process. (when usingCPU750C, CPU750D modules)

3. Program memory 120k step (CPU750D) ∙CPU750A module: 16K STEP(when using extended memory, 32k) ∙CPU750B module: 32k STEP ∙CPU750C module: 60k STEP ∙CPU750D module: 120k STEP

4. Function required in large scaled PLC type was mounted. ∙1ms(0.001 sec.) unit Timer mounted. ∙Floating-Point Operation function (trigonometrical function,

numerical index, algebra, square root) ∙Index register added (14 words, IO.ID) ∙PID command mounted

1. Super high-speed operation speed and sufficient data memory 5. Program edit(insert, delete, correct) function during RUN

6. PID Auto tuning function Parameter set-up can be done by using command of F355(PID),which is an application command

7. Clock(RTC : Real Time Clock) function basically mounted Progress of work is programmable by hours and dates with theembedded clock.

8. RS232C 2 ports mounted on CPU unit ∙Interface to programming tool(WinFRST S/W) with TOOL port ∙Communication with Touch Panel or computer with COM port

9. COM port supports up to 115kbps Program downloading/uploading process can be executed speedilyby drastically improving the communication speed.

10. Corresponds to High speed EtherNet unit, which is an Open Network ∙Enables 100BASE-TX and 10BASE-T (conversion is executed

automatically) ; Use UTP cable ∙10BASE5 ; Use Transceiver cable ∙Data transmission speed : 100M bit/s (in case of 100BASE-TX) ∙Corresponds to TCP/IP and UDP/IP에, able to communicate 8

connections per one unit

11. Comment function that enables annotations on the Ladder program ∙There is a separate RAM for Comments so that comments can be

attached on each interface during programming. Accordingly,conveniently usable when reviewing the Ladder Program or printing.

∙NX-CPU750D : Basically embedded ∙NX-CPU750C : Basically embedded ∙NX-CPU750B : Basically embedded ∙NX-CPU750A : Separate Memory unit required.

WinFPST S/W

High Performance CPU Unit (CPU750)

Communication Cable NX-CBLCPU02NX-CBLCPU05

C-LanguageBASIC

Page 13: Oemax Nx Plc

OEMaxNX Series I 13

항목Relay Symbol Method/ Cyclic Operation Method

1,600 point (2,048 points when using REMOTE)

Basic 16k step (32k steps when extended) Basic 32k step

0.35μs/ 1 command ~

0.93μs/ 1 command ~

95 types

428 types

2,048 points (X0�X127F)

2,048 points (Y0�Y127F) (Usable as internal relay)

4,048 points (R0�R252F)

2,048 points (L0�L127F) (Usable as internal relay)

176 points (R9000�R910F)

1,024 points(points changeable) 1) Timer: 1000 points (T0~T999), 4 types of timers(0.001 Sec. & 3 types) 2) Counter:24points (C1000~C1023)

1,024 points (P0�P63F)

6,000 words(DT0�DT5999)

14.333 words(30717words with extended memory) 30.717words (FL0~FL30716)

256 words (Ld0�Ld255) (Usable as Data Register)

1,024 words (SV0�SV1,023)

1,024 words (EV0�EV1,023)

14 words (I0�ID)

N/A

256point

Total 256points

Unlimited points

Unlimited points (Subtractive 0.01 sec. Timer, 0.01 sec.~ 327.67 sec.)

1,000 process

100 Subroutine

1 program (Timed Interrupt: Time interval range 0.5ms ~ 1.5s .)

Usable(but extended memory is required) Basically embedded (12words x 2,730ea)

Basically embedded(year, month, day, hour, min., sec., week)

Max. 253points

Watchdog Timer, Memory error detection, I/O error detection, Battery error detection, Program grammar check, etc.

PLC Link, Computer Link, Remote Programming, Data Transmission, Modem Function

PID Auto Tuning Function, Using F355(PID) command

User Memory(EPROM & EEPROM execution Function), Programming I/P during RUN, Forced I/O, TEST RUN, Constant Scan function

Approx.10,000 hours, Time saving when using extended memory Approx. 8,000 hours Approx. 3,500 hours

1,600points(8,192points when using REMOTE)

750C Basic:60k step 750D:Basic 120k

0.03μs/ 1 command ~

0.06μs/ 1 command ~

95 types

434 types

8,192p (X0�X511F)

8,192p (Y0�Y511F)

14,192p (R0�R886F)

10,240p (L0�L639F)

3,072points(points changeable) 1) Timer:3000 points (T0�T2999)2) Counter: 72points (C3000�C3071)

10,240words (DT0�DT10239)

32.765words (FL0�FL32764) x 3bank

8,448words (Ld0�Ld8447)

3,072words (SV0�SV3,071)

3,072words (EV0�EV3,071)

14words (I0�ID) x 16bank

2,048points (E0�E2047)

Programming Method/Control Method

Control I/O Point

Program Memory

CommandType

Operation Speed (Rep. Value)

Interface Data(bit)

Mem

ory for Operation

Data M

emory(W

ord)

Sq. command

Appl. command

Basic command

Appl. command

External I/P(X)

External O/P(Y)

Internal Relay(R)

Link Relay(L)

Special Internal Relay (R)

Timer/ Counter(T/ C)

Pulse Relay(P)

Data Register(DT)

File Register(FL)

Link Register(Ld)

Timer/Counter Set Value Area(SV)

Timer/Counter Exp. Value Area(EV)

Index Register (I0~ID)

Error Report Relay(E)

MCR point

No. of Labels (JMP + LOOP No.)

Differential Point

Supplementary Timer (Using F137 Command)

No. of Step Ladder

No. of Subroutine

No. of Interrupt Program

Comment Memory

Clock Function(Calendar Timer)

Shift Register

Self Diagnosis

Link Function

PID Auto Tuning

Other Functions

Memory Backup

ItemsCPU Type

■Performance Specification

NX-CPU750A NX-CPU750BNX-CPU750CNX-CPU750D

0 � 55℃

-25 � 70℃

30 � 85% RH (without condensing)

30 � 85% RH (without condensing)

I/O Terminal(AC) <-> Frame Ground(Power Unit), AC 1500V 1 min.

I/O Terminal(DC) <-> Frame Ground(Power Unit), AC 500V 1 min.

I/O Terminal<-> Frame Ground(Power Unit), Above100MΩ(at DC 500V Mega)

10 ~ 55Hz 1 sweep/ for I min., Dual Vibration Width 0.75mm , X,Y,Z for 10 minutes to each direction

Max. Acc. Impact Speed & time allowance 15g/ 11ms, X, Y, Z directions 3 times each

1500Vp-p Pulse width 50ns, 1μs(according to Noise Simulator)

Corrosive gases and thick dust prohibited

Operating Temp.

Storage Temp.

Operating Humidity

Storing Humidity

SurroundingTemperature

SurroundingHumidity

Withstand Voltage

Insulation Resistance

Vibration Resistance

Impact Resistance

Noise Resistance

Operating Environment

Item Specification

■General Specification

Page 14: Oemax Nx Plc

■Characteristics

1. High speed processing and large capacity memory

Operation speed is 0.4μsec /1command(basic command),

equivalent to that of medium sized PLC and program capacity can

be extended up to 15,871 STEP. I/O control point can be used up to

1,600 points maximum.

2. Forced I/O & Time Chart Monitoring function

Forced input and output on PROGRAM MODE(against Y,R,L) and

on RUN MODE(against X,Y,R, L,T,C) can be done. In addition, the

function of control execution status of 16 points at the same time like

time chart of the logic analyzer is provided so as to be used very

conveniently when PLC monitoring and debugging.

3. Program Edit Function during RUN

Programs can be corrected, deleted and inserted during RUN without

interruption. (also available on Ladder Symbol mode)

4. Password Function

This function sets up Password to protect the User Program, that

does not allow access to the program of PLC by anyone except for

the person concerned so as to prevent the trouble of program in

advance and enhance reliability of the system.

5. 100 % compatibility with the existing N-Series PLC

Compatibility of Commands with the existing N-Series PLC

6. Supports the Handy-Loader that BACKs-Up Programs, etc.

NX-CPU700 module can be interfaced with Handy-

Loader(CPL5119) that has memory back-up function. This

product(CPL5119) has not only the handy type programming tool

function but also has back-up memory embedded to store ladder

program and data so as to store the program(approx. for 3 days).

Accordingly, down loading and up loading of PLC program for this

and that facility can be done with this loader only for convenient use.

7. Add of diverse Command words

SET, RST, Data Transfer Instruction(F70~F78), Compressed shift

instruction(F98, F99), supplementary timer instruction(F137, STMR)

are added so as to enable more command words to be used.

8. Comment Memory that can attach comments on the Ladder

Program is basically embedded

RAM 16K Word(12 letters x 2730 ea) is basically embedded to enable

to attach comments on each interface when preparing programs.

Because that the contents of comment on interfaces and the like are

recorded inside the CPU module, it is convenient to investigate the

contents of instrumentations and the like after several years.

9. EPROM Function(User Memory) is optional

EPROM Socket is optional and the user of EPROM can directly

purchase and input the Ladder Program. Accordingly, PLC program

can be driven with EPROM.

(EPROM Socket: NX-ROM700, EPROM IC : 27C256-12

equivalent, 2 ea required)

Processing speed 0.4us, programming capacity 16k Step, basic unit of NX700 PLC usable, convenient functions like

program editing during RUN are available. In addition, Comment Memory is basically embedded for easy use.

CPU Unit(NX-CPU700)�16k STEP Basic Memory �Comment Memory

EPROM Socket(NX-ROM700)

WinFPST S/W

14 I OEMax NX Series

General Purpose CPU Unit(CPU700)

Comm. Cable NX-CBLCPU02NX-CBLCPU05

Page 15: Oemax Nx Plc

Cyclic operation method

0.4㎲/ 1 Command

Max. 15,871 step(16K Step)

1,600 points

45 types

195 types

2,048 points (X0~X127F)

2,048 points (Y0~Y127F)

1,568 points (R0~R97F)

1,028 points x 2 (L0~L127F)

176 points (R9000~R910F)

Total 256 points ① Timer(0.01 sec. Timer, 0.1 sec Timer, 1 sec. Timer), T0~T199 (points changeable) ② Counter(Pre-set type 1 ~ 32,767Counter) , C200~C255

2,048 words (DT0~DT2047)

128 words x 2 (Ld0~Ld255)

Max. 22,525 words(FL0~FL22524)

256 words(DT9000~DT9255)

256 words(SV0~SV255)

256 words(EV0~EV255)

2 words (IX, IY)

64 points

256 points each

Unlimited

Points Unlimited (Subtractive 0.01 sec. Timer, 0.01 sec. ~ 327.67 sec.)

1,000

100

25 ea

Max. 4,000 ea (1,000 samples) (16 interfaces + 3 words / sample)

Basically embedded, 12 letters x 2,730

① Watchdog Timer ② Memory Error detection ③ I/O error detection ④ Battery error detection ⑤ Program grammar check, etc.

① PLC Link ② Computer Link ③Data Trans. ④REMOTE programming

① EPROM drive function ② Program editing during RUN ③TEST drive

④Forced I/O ⑤Interrupt processing

Lithium Battery Operation Hours: 8,000 Hr

No. of control loops: Max. 32 LOOP, RUN Mode: Forward RUN, Reverse RUN

Sampling Time: 0.1~120.0sec., Control Algorithm: PI-D .I-PD (Please refer to the PID Manual for more details.)

Control Method

Operation Speed

Program Capacity

Max. I/O Processing Point

CommandType

Timer. Counter (T/C)

Interface Data(bit)

Data M

emory(w

ord)

Mem

ory for Operation

Basic Command

Application Command

External I/P (X)

External O/P (Y)

Internal Relay (R)

Link Relay (L)

Special Relay (R)

Data Register (DT)

Link Register (Ld)

File Register (FL)

Special Register (DT)

Timer/Counter Set Value Area (SV)

Timer/Counter Exp. Value Area (EV)

Index Register (IX, IY)

Master Control (MC, MCR)

Label (JMP, LOOP)

Differentials

Supplementary Timer (Using F137 command)

Step Ladder

SUB ROUTINE

Interrupt Program

Sampling Trace

Comment Memory

Self Diagnosis

Other Functions

PID Function

LINK Function

Memory BACK-UP

Item Specification

■Performance Specification

OEMaxNX Series I 15

0 � 55℃

-25 � 70℃

30 � 85% RH (without condensing)

30 � 85% RH (without condensing)

I/O Terminal(AC) <-> Frame Ground(Power Unit), AC 1500V 1 min.

I/O Terminal(DC) <-> Frame Ground(Power Unit), AC 500V 1 min.

I/O Terminal<-> Frame Ground(Power Unit), Above100MΩ(at DC 500V Mega)

10 ~ 55Hz 1 sweep/ for I min., Dual Vibration Width 0.75mm , X,Y,Z for 10 minutes to each direction

Max. Acc. Impact Speed & time allowance 15g/ 11ms, X, Y, Z directions 3 times each

1500Vp-p Pulse width 50ns, 1μs(according to Noise Simulator)

Corrosive gases and thick dust prohibited

Operating Temp.

Storage Temp.

Operating Humidity

Storing Humidity

SurroundingTemperature

SurroundingHumidity

Withstand Voltage

Insulation Resistance

Vibration Resistance

Impact Resistance

Noise Resistance

Operating Environment

Item Specification

■General Specification

Page 16: Oemax Nx Plc

16 I OEMax NX Series

■Characteristics

1. Correction of program during RUN

Correction of program can be done during CPU operation

without stopping the system.

2. PID Processor Embedded

PID control Logic of 8 loop is embedded so that application of

analog control environment such as temperature/RUN control is

exceedingly easy.

3. Clock(RTC : Real Time Clock) function embedded

Work process is programmable by hour and day with the

embedded clock.

4. Sufficient program capacity/ back-up function

Able to program up to max. 20K words and programs can be

stored forever by providing ROM Pack module with FLASH

back-up method adopted.

5. Self Diagnosis Function

Convenient for system error and mal-function detection with the

self diagnosis function.

6. Diverse I/O and basic special module support

DC24V I/P(16/32/64 points), AC110V I/P, AC220V I/P, Relay

O/P, TR O/P(16points/32/64points),SSR O/P, A/D, D/A, RTD,

TC, High Speed Counter (1CH, 2CH), CCU+(Comm. leased),

SCU(Data Processing Device) can be used.

7. Diverse Peripheral Device

Equipped with a leased graphic software(WinGPC S/W) for CPU

control, CPU status check and forced I/O, I/O monitoring and

program download/upload can be done conveniently.

8. Diverse Communication Function

By providing 2 high speed communication ports, computer link

and peripheral devices link without separate module became not

only easier but also COM2 port supports user-defined

communications mode so that bar code reader, Inverter and

servo can be linked and controlled by communication.(Binary

communication available)

NX-CPU700p is a medium-small sized PLC product intended to provide diverse special modules such as function for high speed processing

of the user program, analog and network module in order to respond suitably to the control environments.

�Control Point 100~1000 point high speed processing for optimal control in the medium scaled control environment

<Basic Command: 0.2us>, productivity improvement intended by embedding the PID function, etc.

�High-speed, large capacity data exchange by direct interface with TOUCH PANNEL is enabled by embedding Da2 channel communication

port and the basic special modules of NX700 can be used.(CCU+ unit, SCU unit, Analog unit, high-speed counter(1CH, 2CH) unit)

�By adopting the diverse I/O modules and detachable terminal block, maintenance/repair and design can be done easily.

Processing Speed 0.2us/1 command, Program capacity 20k words, CPU Unit for plus that can use the basic

unit of NX700 PLC.(Uses WinGPC S/W.)

WinGPC S/W

Comm. Cable NX-CBLCPU02NX-CBLCPU05

CPU Unit (NX-CPU700p)

Caution Commands and programming tools for CPU700p

is different from those of CPU750 series

Note) High performance special modules(HSC4, Pulse4, Posi 1~4, MW-Link) can be used at above CPU OS Version2.0.

General Purpose CPU Unit(CPU700P) Plus Family

Computer MMI S/W T/P, etc.

Page 17: Oemax Nx Plc

OEMaxNX Series I 17

Program storing, repetitive operation method

1,600 points (2,048 points when Remote I/O is used)

28 kinds

150 kinds

0.2us/step

0.4~tens of us/step

20K words

R0.0 ~ R127.15 (2048 points, 128 words)

L0.0 ~ L63.15 (1024 points, 64 words)

M0.0 ~ M127.15 (2048 points, 128 words) However, M0.0~ M63.15 can be used as Link Interface

K0.0 ~ K127.15 (2048 points, 128 words)

F0.0 ~ F15.15 (256 points)

256 channel (timer+counter), set value: 0 ~65535 �Timer: 0.01sec.: CH000 ~ CH063 (64 Ch.), 0.1sec.: CH064 ~ CH255 (192Ch.) �Counter: CH000 ~ CH255 (256 Ch.)

W0000 ~ W2047, W3072 ~ W5119 (4096 words)

W2560(=SR000)~W3071(=SR511) (512 words)

year, month, day, hour, minute, second, week

Port 1 : RS232C/ RS485 Dual use, 9600/ 19200/ 38400 bps

Port 2 : User Memory(EPROM & EEPROM Drive Function), Program I/P during RUN, Forced I/O, TEST RUN,

Constant Scan Function

Approx. 8,000 hours

Control Method

External I/O

Program Capacity

Command

ProcessingSpeed

Basic Command

Appl. Command

Basic Command

Appl. Command

I/O Interface (R)

Link Interface (L)

Internal Interface(M)

Electrostatic maintenance Interface (K)

Special Interface (F

Data Register (W)

Special Reg.(W,SR)

Timer/ Counter

Interface(TC or TIM)

CPU Type NX-CPU700p

■Performance Specification

Clock Function (RTC)

Communication

Function

Port 1

Port 2

FLASH ROM Backup

Capacity ofData Memory

0 � 55℃

-25 � 70℃

30 � 85% RH (without condensing)

30 � 85% RH (without condensing)

I/O Terminal(AC) <-> Frame Ground(Power Unit), AC 1500V 1 min.

I/O Terminal(DC) <-> Frame Ground(Power Unit), AC 500V 1 min.

I/O Terminal<-> Frame Ground(Power Unit), Above100MΩ(at DC 500V Mega)

10 ~ 55Hz 1 sweep/ for I min., Dual Vibration Width 0.75mm , X,Y,Z for 10 minutes to each direction

Max. Acc. Impact Speed & time allowance 15g/ 11ms, X, Y, Z directions 3 times each

1500Vp-p Pulse width 50ns, 1μs(according to Noise Simulator)

Corrosive gases and thick dust prohibited

Operating Temp.

Storage Temp.

Operating Humidity

Storing Humidity

SurroundingTemperature

SurroundingHumidity

Withstand Voltage

Insulation Resistance

Vibration Resistance

Impact Resistance

Noise Resistance

Operating Environment

Item Specification

■General Specification

Page 18: Oemax Nx Plc

18 I OEMax NX Series

Motherboard

AC110~220V,Free V

540mA max

AC 85 ~ 264V

47 ~ 63Hz

Below20A

5V 4.0A, 24V 0.5A

Approx. 350g

AC 220V

300mA Max

AC 176 � 264V

47 � 63Hz

Below20A

5V 6.0A

Approx. 300g

I/P Rated Voltage

I/P Rated Current

Allowable V. range

I/P Power Frequency

Rush Current

Rated O/P Current

Weight

Product No. NX-POWER NX-PWR220

DC 24V

1.7A man

DC 21.6�26.4V

5V 5.0A

Approx. 320g

I/P Rated Voltage

I/P Rated Current

Allowable Voltage Range

Rated O/P Current

Weight

Product No. NX-PWRDC

■Performance Specification■Photo of the Product

�Number of slots of the motherboard is the number of I/O modules and special modules that can be mounted.

�Motherboard of NX700 PLC is used without distinction between basic and extended motherboards.

�Only 1 panel of motherboard can be added to NX700 PLC.

Caution

3 slot Motherboard (NX-BASE03)

10 slot Motherboard (NX-BASE10)

12 slot Motherboard (NX-BASE12)

8 slot Motherboard (NX-BASE08)

Power Unit

5 slot Motherboard (NX-BASE05)

Power(Electricity Source)Unit

Page 19: Oemax Nx Plc

OEMaxNX Series I 19

■Characteristics

■External Electrical Schematic Diagram

�16 points, 32 points, 64 points I/P Unit

�DC I/P type can use +, -COMMON for all

�Confirmation of operation by LED display

�Photocoupler Insulation for all modules

�Extended user convenience by separating

Terminal blocks (16 point module)

16point TYPEI/P Unit

32point TYPEI/P Unit

64point TYPEI/P Unit

Caution The numbers(1~40) in the below diagram(NX-X32D/ NX-X64D) indicate the numbers

printed on the front side of the product.

NX-X16D

16 point

65mA

8 point/ 1COM(Polarity+,- Common)

Detachable Terminal Block (M3.5)

12 ~ 24V DC

10.2 ~ 26.4V DC

Below 10ms

Min. 9.6V

Max. 2,5V

100 ~ 120V AC

85 ~ 132V AC

Below 20ms

Min. AC 80V

Max. AC 30V

200 ~ 240V AC

170 ~ 264V AC

Below 20ms

Min. AC 160V

Max. AC 50V

Below 15ms

Below 20ms

60mA

Below 15ms

Below 20ms

60mA

10ms 이하

10ms 이하

130mA

40P Connector x 1 40P Connector x 2

10ms 이하

10ms 이하

250mA

Photocoupler Insulation

LED Display (but 64 point is transferred and displayed by 32 points each)

32point/ 1COM (Polarity+,- Common)

Detachable Terminal Block(M3.5)

8 point/ 1COM

NX-X32D

32 point

NX-X64D

64 point

NX-X16A110

16 point

NX-X16A220Product Code

Input Point

Rated I/P Voltage

Operating V. Range

Max. I/P Current

Internal Operating Current

COMMON Method

Operation Display

External Interface Method

ON Voltage

OFF Voltage

OFF→ON

ON→OFF

OperatingVoltage

RespondingTime

Withstand Voltage

Input Mode DC Input AC Input

■ I/P Unit Specification

NX-X16D NX-X32D NX-X64D NX-X16A110/ NX-X16A220

(Note1) NX-X16A220: AC 200-240V

(Note)

(Ⅰ) (Ⅱ)

I/P Unit

Below 10ms

Below 10ms

Page 20: Oemax Nx Plc

20 I OEMax NX Series

NX-Y16T

16 point

NX-Y16R NX-Y16RV

16 point

NX-Y32RV

32 point

NX-Y16SSR

16 point

SSR

100V~240V AC

85V ~ 264V AC

0.5A/point, 2A/COM

Below 1㎳

0.5CYCLE+below 1m

250㎃

N/A

3.0A

8point/COM

12V ~ 24V DC

10V ~ 30V DC

250V AC, 30V DC

85 V ~ 264V AC, 10V~30V DC

Below 1㎳

Below 1㎳

Below 10㎳

Below 10㎳

NX-Y32T

32 point

NX-Y64T

16 point

Photocoupler Insulation

0.6A /point 0.4A /point 0.2A /point 2A/ point, 5A/ COM 1A/point, 3A/COM

120㎃ 120㎃180㎃ 180㎃

8point/COM 8point/COM

Detachable Terminal Block (M3.5) Detachable Terminal Block M3.5)40P Connectorx1

32point/COM 32point/COM

Zener Diode N/A

N/A

바리스터

LED Display (But 64 point is transferred and displayed by 32 points each)

250㎃

Detachable Terminal Block M3.5) 40P Connectorx1 40P Connectorx2

Product Code

Output Point

Insulation Method

Rated Load Voltage

Operating Load Voltage Range

Max. Load Current

Internal Operating Current(5V)

Surge Killer

Fuse Rating

COMMON Method

Operation Display

External Interface Method

OFF→ON

ON→OFF

Responding

Time

O/P Mode Transistor(NPN) Output Relay Output SSR Output

■O/P Unit Specification

■External Electrical Schematic DiagramCaution The numbers (1~40) in the below diagram(NX-Y32T/ NX-Y64T, NX-Y32RV) indicate the

numbers printed on the front side of the product.

■Characteristics

�16 points, 32 points, 64 points I/P Unit

�Confirmation of operation by LED display

�Photocoupler Insulation for all modules

�Extended user convenience by separating

Terminal blocks (16 point module)

16point TYPEO/P Unit

32point TYPEO/P Unit

64point TYPEO/P Unit

NX-Y16T NX-Y32T/ NX-Y64T NX-Y16R/ NX-Y16RV NX-Y32RV NX-Y16SSR

Max.

250V AC

30V DC

AC100~240V

O/P Unit

250VAC30VDC

Page 21: Oemax Nx Plc

■General Purpose CPU(WinFPST S/W adopted)

■General Purpose Plus CPU (WinGPC S/W adopted)

■NX70-CPU70

■NX70-CPU750

■NX70-CPU70p1

■NX70-CPU70p2

NX

70 Series

*Refer to the attached■High Performance CPU(WinFPST S/W adopted)

OEMaxNX Series I 21

Page 22: Oemax Nx Plc

22 I OEMax NX Series

■Free System Configuration: 7 kinds of Motherboard ( 2 slot, 3 slot, 4 slot, 5 slot, 6 slot, 8 slot, 10slot, 12 slot)

■Slot Number Display

■12 Module Type

■8 Module Type

■10 Module Type

■2 Module Type ■3 Module Type

(NX70-BASE02)32p:16p I/O configured 64p:32p I/O configured

(NX70-BASE08)128p:16p I/O configured256p:32p I/O configured

(NX70-BASE12)196p:16p I/O configured 384p:32p I/O configured

�NX70 PLC has 7 kinds of motherboards which can be mounted with each kinds of I/O units freely.

�I/O Module, Power (Electricity source) Module, Special Module and Motherboard are common regardless of CPU Types.

(CPU Type, 4 kinds: NX70-CPU750, CPU70, CPU70p1, CPU70p2)

�Display of slot numbers on the motherboard indicates the number of mountable I/O units and special modules.

(ex. 12 slot typed NX70-BASE12 motherboard can mount up to 12 I/O units and special modules.)

■Maximum Control I/O Point 384 Points

�When 12 slot motherboard is used, NX70 PLC is able to use up to max.(192 points for Terminal Block).

�NX70 PLC can not be used with extension. (Only basic motherboard is available.)

■Module Compatibility between NX70 PLC and N70 PLC

All modules of N70 PLC and NX70 PLC are mutually compatible except for CPU module, motherboard module and power module.

ex1) CPU(CPL9211A..) and Power Module(CPL9631..) can not be mounted on NX70 motherboard (NX70-BASE02~ NX70-BASE12).

ex2) Existing I/O of N70 and Special Module can be mounted on NX70 (NX70-BASE02~ NX70-BASE12).

ex3) CPU of NX70 and Power Module can not be mounted on N70 motherboard (CPL9502 ~ CPL9508).

(NX70-BASE10)160p:16p I/O configured 320p:32p I/O configured

(NX70-BASE03)48p:16p I/O configured 96p:32p I/O configured

(NX70-BASE04)64p:16p I/O configured 128p:32p I/O configured

(NX70-BASE06)96p:16p I/O configured 192p:32p I/O configured

�Basic configuration of system and I/O control point are equal regardless of the CPU types. (CPUTypes: NX70-CPU750, NX70-CPU70, NX70-CPU70p1, NX70-CPU70p2)

■4 Module Type

■6 Module Type

Basic Configuration of NX70

(NX70-BASE05)80p:16p I/O configured 160p:32p I/O configured

■5 Module Type

Basic Configuration and Control I/O point

Page 23: Oemax Nx Plc

OEMaxNX Series I 23

■Configuration of units that can be mounted

×

×

×

×

×

×

×

×

×

×

■Restrictions according to the types of units

Kinds of Common Units

Kinds of CPU Units

NX70-CPU750

NX70-CPU70

NX70-CPU70p1

NX70-CPU70p2

AdvancedCPU

CommonCPU

Basic Unit Special Unit Network Unit

Motherboard (2,3,5,6, 8,10,12 slot)

(NX70-BASE02, 03, 05, 06, 08, 10, 12)

AC Power Unit (for all slots) ( NX70-POW

ER1, NX70-POWER2 )

Input Unit

Output U

nit

A/D, D

/A, RTD, TC

Unit

High Speed Counter Unit (1, 2CH)

High Performance High Speed

Counter Unit (4CH)*2

Pulse O/P Unit (4CH) *2

Positioning Unit(2,4 axes)

(Open C

ollector & Line D

rive)

SCU U

nit (2CH)

CCU U

nit (1CH) *1

×

×

CCU+

Unit (1C

H) *1

MW

-Link U

nit(W

-M

ode, W2-

Mode) *1*2

W-

Link Unit (W

-M

ode) *1

REMO

TE SLAVE Unit) *

UseProgramming

Tool

WinFPST S/W

WinFPST S/W

WinGPC S/W

DC Pow

er Unit (for all slots)

( NX70-

PWRD

C )

○ : Usable △ : Usable according to Version × : Unusable

Special Unit

�A/D, D/A, RTD, TC

�CCU, SCU unit

�High Speed Counter (1/ 2CH)

�High Performance High

Speed Counter (4CH)

�Pulse Output unit (4CH)

�Positioning Unit

�Remote I/O SYSTEM

�W-LINK SYSTEM

�MW-LINK SYSTEM

�DeviceNet SYSTEM

CPU Unit

Electricity Source(Power) unit

�AC Type1) NX70-POWER1(110/ 220V, Free Volt)5V 4.0, 24V 0.3A

2) NX70-POWER2(110/ 220V, Free Volt)5V 4.5A

�DC Type 1) NX70-PWRDC(DC24V, Input)5V 4.5A

�NX70-CPU7016k StepComment MemoryComm. port 1port

�NX70-CPU75032k StepComment MemoryComm. port 2port

�NX70-CPU70P1 9.6k word Comm. port 1port

�NX70-CPU70P2 20k word Comm. port 2port

Peripheral Device

�Computer Software

- WinFPST S/W(for CPU70, CPU750)

- WinGPC S/W(for CPU70p)

�Computer Interface Cable

Motherboard

I/O Unit

�8p/8pmixed type

�16/16p mixed type

�16 point type

�32 point type

※NX70 Series can not be extended.

※Display of slot number indicates the number

of mountable I/O and Special Units.

※1. Restriction on mounting Link-family Units

※2. High performance high-speed counter (NX70-HSC4) and Pulse O/P Unit (NX70-PULSE4), Positioning Unit (NX70-POSI2/4) and MW-Link Units can be used on

NX70-CPU750 Module only.

CCU unit

CCU+ unit

W-Link unit (W-Mode)

WM-Link unit

(W-Mode, W2-Mode)

Up to 3 units including CCU unit can

be used. But, PLC Link function is up

to 2 units only

Up to max. 3 units can be used but

PLC Link function is up to 2 units only

(NX70-CPU70p1 can not be used)

Up to 3 units including CCU unit can be

used. But, PLC Link function is up to 2

units only

Up to 5 units can be used(but PLC Link

function is up to 2 units only)

Only 1 unit can be used

Unable to use

Unable to use Can be used

Usable according to versions

(W-mode)

Unable to use

Kinds of Unit In case of NX70-CPU70 module In case of NX70-CPU750 moduleIn case of NX70-CPU70p1, NX70-CPU70p2 module

�2 slot type

�3 slot type

�4 slot type

�5 slot type

�6 slot type

�8 slot type

�10 slot type

�12 slot type

Caution Mutually compatible except for the existing power module, CPU module and motherboard of N70 PLC.(Ex. N70 I/O module can be used with NX70 motherboard) (Ex. N70 CPU(CPL9211A) can not be used with NX70 motherboard)

×

System Configuration

Page 24: Oemax Nx Plc

24 I OEMax NX Series

■Characteristics

High speed medium-large scaled PLC with Maximum Processing Speed 0.03us, Capacity of Program 32k, Sharing same

Commands with CPU750 Series for N700 and Comment Memory, PID Auto Tuning Function and two communication

ports basically embedded. In addition, large scaled PLC function is compressed into compact size for easy use.

NX70-CPU750�32k STEP�0.35us�Clock Function �Comment Memory, PID Auto Tuning�2 Ports (RS232C)

COM Port

Computer

T/P

WinFPST S/W

TOOL Port NX-CBLCPU02,05

1. Operation Speed and Sufficient Data Memory

2. Program Memory 32k step

3. Functions required by the Large scaled PLC mounted.

∙1ms(0.001 sec.) unit Timer mounted.

∙Floating Point Operation Function (Trigonometric Function,

Index, Algebra, Square Root)

∙Index Register added (14 words, I0~ID)

∙PID Command Words Embedded

4. Program Edit(insert, delete and correct) Function during RUN

5. PID Auto Tuning Function

Able to set up Parameter with Command Words, which are

Application Command Words F355(PID)

6. Clock(RTC : Real Time Clock) Function embedded basically

Work process is programmable by hour and day with the

embedded clock. .

7. RS232C 2 ports mounted on CPU Unit

∙Programming tool(WinFPST S/W) interface with TOOL port

∙Communication with Touch Panel or computer, etc., with COM Port

8. Comm. Port supports up to 115kbps

With drastic improvement of communication speed, program

downloading/uploading can be executed speedily. (Comment is

embedded basically.)

9. Comment Memory that can attach comments on the Ladder

Program is basically embedded

Separate RAM for Comment enables attachment of comments

on each interface when preparing programs. Accordingly, it can

be used conveniently when reviewing the ladder program or after

printing.

10. Special Units of NX70 PLC can be used

NX70-CPU750 Unit can use Pulse I/O Unit(4CH) and high

performance high sped counter(4CH), positioning unit(2 axis/4

axis) and MW-Link unit. (Impossible with the other CPU

modules)

0.35μs

0.93μs�

32k step

2,048 p

2,048 p

4,048 p

6,000 words

30,717 words

2,048 p

256 words

1,024 p

1,024 p

14 words

Program Capacity

I/P Relay(X)

O/P Relay(Y)

Internal Relay(R)

Data Register(DT)

File Register(FL)

Link Relay(L)

Link Register(Ld)

Timer/ Counter(T/C)

Pulse Relay(P)

Index Register

Sq. Command

Appl. Command

Data Capacity

Operation Command(per 1 Command)

0.4μs

Tens of μs�

16k step

2,048 p

2,048 p

1,568 p

2,048 words

22,525 words

1,024 p

128 words

256 p

N/A

2 words

NX70-CPU750ItemCPU Type NX70-CPU70

CPU Unit (NX70-CPU750)

C-Language BASIC

Page 25: Oemax Nx Plc

OEMaxNX Series I 25

Program Method/Control Method

Control I/O Point

Program Memory

Sq. Command

Appl. Command

Basic Command

Appl. Command

External I/P (X)

External O/P (Y)

Internal Relay (R)

Link Relay (L)

Special Internal Relay (R)

Timer/ Counter (T/C)

Pulse Relay(P)

Data Register (DT)

File Register (FL)

Link Register (Ld)

Timer/Counter Set Value Area (SV)

Timer/Counter Exp. Value Area (EV)

Index Register (IO, DO)

MCR Point

No. of Labels (JMP + LOOP No.)

Differential Point

Supplementary Timer (Using F137 command)

Step Ladder

SUB ROUTINE

Interrupt Program

Comment Memory

Clock Function(Calendar timer function)

Shift Register

Self Diagnosis

Link Function

PID Auto Tuning

Other Functions

Memory Back-up

Interface Data(bit)

Mem

ory for Operation D

ata Mem

ory(word)

OperationSpeed

(Rep. Value)

NX70-CPU750ItemCPU Type

■Performance Specification

Relay Symbol Method/ Cyclic Operation Method

384 point

Basic 32k step

0.35μs/ 1 command ~

0.93μs/ 1 command ~

95 kinds

428 kinds

2,048point (X0�X127F)

2,048point (Y0�Y127F) (usable as an Internal Relay)

4,048point (R0�R252F)

2,048point (L0�L127F) (usable as an Internal Relay)

176point (R9000�R910F)

1,024 point(points changeable) 1) Timer: 1000 point (T0~T999), 4 kinds of Timers(0.001sec.,0.01sec.,0.1sec.,1.0sec.,) 2) Counter: 24point (C1000~C1023)

1,024point (P0~P63F)

6,000word (DT0~DT5999)

0.30.717word (FL0~FL30716)

256word (Ld0~Ld255) (Usable as an DT)

1,024 word (SV0~SV1,023)

1,024word (EV0~EV1,023)

14word (I0~ID)

256 point

Total 256 point

Unlimited

Unlimited( Retractive type 0.01sec.Timer, 0.01sec.~327.67sec.)

1,000 work process

100 Sub Routine

1 Program (On time Interrupt: Time interval can be set up within the range of 0.5ms ~ 1.5s.)

Basically embedded (12letters x 2,730ea)

Basically embedded(y, m, d, h, m, s, week)

Max. 253 point

Watchdog Timer, Memory error detection, I/O error detection, Battery error detection, Program grammar check, etc.

PLC Link, Computer Link, Remote Programming, Data Transmission, Modem Function

PID Auto Tuning Function, Use F355(PID) command words

User Memory(EPROM & EEPROM Drive Function), Program I/P during RUN, Forced I/O, TEST RUN, Constant Scan Function

Approx. 8,000 hours

0 � 55℃

-25 � 70℃

30 � 85% RH (without condensing)

30 � 85% RH (without condensing)

I/O Terminal(AC) <-> Frame Ground(Power Unit), AC 1500V 1 min.

I/O Terminal(DC) <-> Frame Ground(Power Unit), AC 500V 1 min.

I/O Terminal<-> Frame Ground(Power Unit), Above100MΩ(at DC 500V Mega)

10 ~ 55Hz 1 sweep/ for I min., Dual Vibration Width 0.75mm , X,Y,Z for 10 minutes to each direction

Max. Acc. Impact Speed & time allowance 15g/ 11ms, X, Y, Z directions 3 times each

1500Vp-p Pulse width 50ns, 1μs(according to Noise Simulator)

Corrosive gases and thick dust prohibited

Operating Temp.

Storage Temp.

Operating Humidity

Storing Humidity

SurroundingTemperature

SurroundingHumidity

Withstand Voltage

Insulation Resistance

Vibration Resistance

Impact Resistance

Noise Resistance

Operating Environment

Item Specification

■General Specification

Page 26: Oemax Nx Plc

26 I OEMax NX Series

■Characteristics

Processing Speed 0.4us, Capacity of Program 16k and convenient functions like program editing during RUN included.

In addition, Comment Memory is basically embedded for convenience of users.

1. High speed processing and large capacity memory

Operation speed is 0.4μsec /1command(basic command) and

program capacity can be extended up to 15,871 STEP. I/O

control point can be used up to 384 points maximum.

2. Forced I/O & Time Chart Monitoring function

Forced input and output on PROGRAM MODE(against Y,R,L)

and on RUN MODE(against X,Y,R, L,T,C) can be done. In

addition, the function of control execution status of 16 points at

the same time like time chart of the logic analyzer is provided so

as to be used very conveniently when PLC monitoring and

debugging.

3. Program Edit Function during RUN

Programs can be corrected, deleted and inserted during RUN

without interruption of PLC. (also available on Ladder Symbol

mode)

4. Password Function

This function sets up Password to protect the User Program, that

does not allow access to the program of PLC by anyone except

for the person concerned so as to prevent the trouble of program

in advance and enhance reliability of the system.

5. 100 % compatibility with the existing N-Series PLC

6. Supports the Handy-Loader that BACKs-Up Programs, etc.

NX-CPU700 module can be interfaced with Handy-

Loader(CPL5119) that has memory back-up function. This

product(CPL5119) has not only the handy type programming tool

function but also has back-up memory embedded to store

ladder program and data so as to store the program(approx. for 3

days). Accordingly, down loading and up loading of PLC

program for this and that facility can be done with this loader only

for convenient use.

7. Add of diverse Command words

SET, RST, Data Transfer Instruction (F70~F78), Compressed

shift instruction(F98, F99), supplementary timer instruction(F137,

STMR) are added so as to enable more command words to be

used.

8. Comment Memory that can attach comments on the Ladder

Program is basically embedded

RAM for Comment (12 letters x 2730 ea) is basically embedded

to enable to attach comments on each interface when preparing

programs. Because that the contents of comment on interfaces

and the like are recorded inside the CPU module, it is convenient

to investigate the contents of instrumentations and the like after

several years..

NX70-CPU70�16k STEP Basic Memory

�Comment Memory

WinFPST S/W

CableNX-CBLCPU02,05

CPU Unit(NX70-CPU70)

Page 27: Oemax Nx Plc

OEMaxNX Series I 27

Control Method

Operation Speed

Program Capacity

Max. I/O Processing Speed

Basic Command

Application Command

External I/P (X)

External O/P (Y)

Internal Relay (R)

Link Relay (L)

Special Relay (R)

Data Register (DT)

Link Register (Ld)

File Register (FL)

Special Register (DT)

Timer/Counter Set Value Area (SV)

Timer/Counter Exp. Value Area (EV)

Index Register (IX, IY)

Master Control (MC, MCR)

Label (JMP, LOOP)

Differentials

Supplementary Timer(use F137 Command)

Step Ladder

Sub Routine

Interrupt Program

Sampling Trace

Comment Memory

Self Diagnosis

Other Functions

PID Function

LINK Function

Memory BACK-UP

CommandTypes

Interface Data(bit)

Mem

ory for Operation

Data M

emory(w

ord)

Timer/ Counter (T/C)

NX70-CPU70ItemCPU Type

■Performance Specification

Cyclic operation method

0.4㎲/ 1 Command

Max. 15,871 Step (16K Step)

384 points

45 types

195 types

2,048 p (X0~X127F)

2,048 p (Y0~Y127F)

1,568 p (R0~R97F)

1,028 p x 2 (L0~L127F)

176 p (R9000~R910F)

Total 256 point ①Timer(0.01sec.Timer, 0.1sec Timer, 1sec. Timer), T0~T199 (Points changeable) ②Counter(Pre-set Type 1 ~ 32,767Counter), C200~C255

2,048words (DT0~DT2047)

128 words x 2 (Ld0�Ld255)

최 22,525워드(FL0�FL22524)

Max. 22,525 words(FL0~FL22524)

256 words(DT9000~DT9255)

256 words(SV0~SV255)

2 words (IX, IY)

64 points

256 points each

Unlimited

Point Unlimited (Retractive Type 0.01sec. Timer, 0.01sec.~327.67sec.)

1,000

100

25 ea

Max. 4,000ea (1,000 sample) (16interface + 3word / sample)

Basically embedded, 12letters x 2,730

①Watchdog Timer ②Memory error detection ③ I/O error detection④Battery error detection ⑤Program grammar check

①PLC Link ②Computer Link ③Data Transmission ④REMOTE Programming

①Program editing during RUN ②TEST Drive③Forced I/O ④ Interrupt Process

Lithium Battery Operation Hour 8,000 Hr

No. of control loops: Max. 32 LOOP, RUN Mode: Forward RUN, Reverse RUN Sampling Time: 0.1~120.0sec., Control Algorithm: PI-D ∙I-PD (Please refer to the PID Manual for more details.)

0 � 55℃

-25 � 70℃

30 � 85% RH (without condensing)

30 � 85% RH (without condensing)

I/O Terminal(AC) <-> Frame Ground(Power Unit), AC 1500V 1 min.

I/O Terminal(DC) <-> Frame Ground(Power Unit), AC 500V 1 min.

I/O Terminal<-> Frame Ground(Power Unit), Above100MΩ(at DC 500V Mega)

10 ~ 55Hz 1 sweep/ for I min., Dual Vibration Width 0.75mm , X,Y,Z for 10 minutes to each direction

Max. Acc. Impact Speed & time allowance 15g/ 11ms, X, Y, Z directions 3 times each

1500Vp-p Pulse width 50ns, 1μs(according to Noise Simulator)

Corrosive gases and thick dust prohibited

Operating Temp.

Storage Temp.

Operating Humidity

Storing Humidity

SurroundingTemperature

SurroundingHumidity

Withstand Voltage

Insulation Resistance

Vibration Resistance

Impact Resistance

Noise Resistance

Operating Environment

Item Specification

■General Specification

Page 28: Oemax Nx Plc

■Characteristics

As a small sized PLC, CPU70p has Processing Speed of 0.2us/ 1 Command and 20k Words of Program Capacity (9.6k

words for CPU70p1) so as to easily process programming and intended high speed and high performance.

WinGPC S/W is supported as a programming tool.

1. Processing Speed of Command Words

With the leased IC for high speed processing, the processing

speed of basic command words reaches 0.2usec/STEP so as to

enable high speed processing.

2. Correction of Program during RUN

Program can be corrected during CPU drive without interrupting

the system.

3. Clock(RTC : Real Time Clock) function

With the embedded clock, the work process is programmable by

hour and by date. (Supports on NX70-CPU70p2 module only)

4. Sufficient Program Capacity/ Back-up Function

Able to program up to Max.20k words(NX70-CPU70p2) and

9.6k words(NX70-CPU70p1). With Flash Back-up method

adopted, programs can be stored separately.

5. Self Diagnosis Function

Self Diagnosis function can be used conveniently for detection of

system error or malfunction

6. WinGPC Software

With WinGPS S/W, which is a leased graphic software for CPU

control, CPU status check and forced I/O, I/O monitoring and

program downloading/uploading can be done conveniently.

7. Diverse I/O and basic special module support

DC24V I/P(16/32/64 points), AC110V I/P, AC220V I/P, Relay O/P,

TR O/P(16points/32points),SSR O/P, A/D(4CH), D/A(4CH),

RTD(4CH), TC(4CH), High Speed Counter, SCU(Data

Processing Device) can be processed.

8. Preparation of Diverse Motherboards (up to 12 slot motherboard)

2 slot, 3 slot, 5 slot, 6 slot, 8 slot, 10 slot, 12 slot motherboards

each can be selected when configuring the system.

9. Maximum Control I/O Point 384 Points

�When 12 slot motherboard is used, NX70 PLC is able to use up

to max. 384 points(192 points for Terminal Block)

�NX70 PLC can not be used with extension.

10. RS232C/ RS485, 2 ports mounted (NX70-CPU70p2 Module)

With 2 CH Communication Ports embedded, direct interface with

computer and Touch Panel enables large quantity data

exchange, and COM2 port supports user-defined

communications mode so that bar code reader, Inverter and

servo can be linked and controlled by communication.(Binary

communication available).

Computer WinGPC

Comm. Cable NX-CBLCPU02,05

28 I OEMax NX Series

NX70-CPU70p1�9.6kword basic memory

�1port (RS232C/ RS485)

NX70-CPU70p2�20kword basic memory

�2port (RS232C/ RS485)

�Clock Function

General Purpose CPU Unit (NX70-CPU70p1) (NX70-CPU70p2)Programming tool of CPU module for plus is WinGPC S/W.Caution

Page 29: Oemax Nx Plc

Control Method

External I/O

CommandWords

ProcessSpeed

I/O Interface (R)

Link Interface(L)

Internal Interface (M)

Keep during Blackout(停電維持) Interface (K)

Special Interface (F)

Data Word(W)

Special Word (W,SR)

Digital

Analog

Basic Command

Appl. Command

Basic Command

Appl. Command

Program Capacity

Clock Function (RTC)

FLASH ROM Support(Backup)

Comm.Function

Timer/ CounterInterface (TC or TIM)

Port 1

Port 2

NX70-CPU70p1 NX70-CPU70p2CPU Type

■Performance Specification

0 ~ 55℃

-25 � 70℃

30 � 85% RH (without condensing)

30 � 85% RH (without condensing)

I/O Terminal(AC) <-> Frame Ground(Power Unit), AC 1500V 1 min

I/O Terminal(DC) <-> Frame Ground(Power Unit), AC 500V 1 min

I/O Terminal <-> Frame Ground(Power Unit), Above100MΩ(at DC 500V Mega)

10 ~ 55Hz 1 sweep/ for I min., Dual Vibration Width 0.75mm , X,Y,Z for 10 minutes to each direction

Max. acc. Impact Speed & time allowance 15g/ 11ms, X, Y, Z directions 3 times each

1500Vp-p Pulse width 50ns, 1μs (according to Noise Simulator)

Corrosive gases and thick dust prohibited

Program Storage, Repetitive Operation Method

384 point (32 point module / 12 Slots)

48 CH (4 CH Module / 12 Slots)

28 kinds

150 kinds

0.2 μs/step

1.0 ~ tens of μs/step 0.8 ~ tens of μs/step

9.6K word 20K word

2,048points (R0.0 ~ R127.15)

1,024points (L0.0 ~ L63.15)

2,048points (M0.0 ~ M127.15), (But, usable as Link Interface range with NX70-CPU70p2, 64 word)

2,048points (K0.0 ~ M127.15)

256points (F0.0 ~ F15.15)

256 CH (Timer+Counter), Set-up value: 0 ~65535

Timer: 0.01sec.: CH000~CH063 (64CH), 0.1sec.: CH064~CH255 (192CH)

Counter: CH000 ~ CH255 (256CH)

2,048word (W0000 ~ W2047) 4,096word (W0000~ W2047), (W3072~ W5119)

512word W2560(=SR000) ~ W3071(=SR511)

N/A Y, M, D, H, M, S, Week

RS232C/ RS485 Combined Use, 4800/ 9600/ 19200/ 38400bps

N/A RS232C/ RS485 Combined Use, 4800�38400bpsCan support User definition

User PROGRAM Back up embedded

Operating Temp.

Storage Temp.

Operating Humidity

Storing Humidity

SurroundingTemperature

SurroundingHumidity

Withstand Voltage

Insulation Resistance

Vibration Resistance

Impact Resistance

Noise Resistance

Operating Environment

Item Specification

■General Specification

OEMaxNX Series I 29

�K, W, Counter PV Register maintain during power failure. �CPU Unit is able to back-up User Program and some specific registers for 48 hours by embedded Super Capacitor when the Battery is off.

Programming tool of CPU module for plus is WinGPC S/W.Caution

Page 30: Oemax Nx Plc

�Number of slots of the motherboard is the number of I/O modules and special modules that can be mounted. �Motherboard of NX70 PLC is the Basic motherboard only. (can not be extended)

Caution

■Photo of the Product

Power Unit

2 slot Motherboard

(NX70-BASE02)

3 slot Motherboard

(NX70-BASE03)

4 slot Motherboard

(NX70-BASE05)

Basic Motherboard

AC 110�220V, Free Voltage / 450mA max

AC 85 � 264V

47 � 63Hz

Below 20A

5V 4.0A

24V 0.3A

47 � 63Hz

Below 20A

5V 4.5A

N/A

I/P Rated Voltage/ Current

Permissible Voltage Range

I/P PWR Frequency

Inrush Current

Rated O/P Current(5V)

Rated O/P Current(24V)

Product No. NX70-POWER1 NX70-POWER2

■Performance Specification

DC 24V / 1.54A max

DC 21.6�26.4V

5V 4.5A

I/P Rated Voltage/ Current

Permissible Voltage Range

Rated O/P Current(5V)

Product No. NX70-PWRDC

30 I OEMax NX Series

POWER(Electricity Source) UNIT

6 slot Motherboard

(NX70-BASE06)

8 slot Motherboard

(NX70-BASE08)10 slot Motherboard

(NX70-BASE10)

12 slot Motherboard (NX70-BASE12)

5 slot Motherboard

(NX70-BASE05)

Page 31: Oemax Nx Plc

■Photo of the Product

24V DC

21.6~ 26.4V DC

Above 20V DC

Below 7V DC

■External Electrical Schematic Diagram

NX70-X16D

12 ~ 24V DC

10.2 ~ 26.4V DC

Above 9.6V DC

Below 2.5V DC

24V DC

21.6~ 26.4V DC

Above 20V DC

Below 7V DC

100~120V AC

85~132V AC

Below 20mA

Min. above AC 80V

Max. below AC30V

Approx. 15kΪ

Below 1

Below 10ms

80mA

8 point/ 100M

200~240V AC

170~ 274V AC

Min. above AC 160V

Max. below 50V

12 ~ 24V DC

10.2 ~ 26.4V DC

Above 9.6V DC

Below 2.5V DC

NX70-X16D1 NX70-X32D NX70-X32D1 NX70-X16A110 NX70-X16A220

16 point TYPE 32 point TYPE

NX70-X16DNX70-X16D1

NX70-X32DNX70-X32D1

NX70-X16A110NX70-X16A220

Caution The numbers (1~20) in the below diagram(NX70-X16D/ NX70-X32D) indicate the numbers

printed on the front side of the product.

(Note1) I/P Voltage of NX70-X16A220module is AC 200-240V only.

※ Careful interfacing is required because that the directions ofConnector (Ⅰ) and (Ⅱ) is opposite.

(Note 1). I/P voltage of NX70-X32D1 module is leased DC 24V only

※ NC : No Connection

(Note 1) I/P voltage of NX70-X60D1

module is leased DC 24V only

(Note1)

�16 point, 32 point I/P Unit

�DC I/P Type is able to use both +,

-COMMON

�Confirmation of operation by LED Display

�Photocoupler Insulation for all modules

�Connector Type (32 point) can get much

larger I/O numbers per each area.

I/P Point

Rated I/P Voltage

Operating Voltage Range

Max. Pressure Current

I/P Impedance

Internal Operating Current

COMMON Method

External Interface Method

Product Code

Operating Voltage

RespondingTime

ON Voltage

OFF Voltage

OFF→ON

ON→OFF

I/P Mode DC I/P AC I/P

■I/P Unit Specification

Approx. 3k Ϊ

Below 10ms

Below 10ms

Approx. 3k65mA

8 point/ 100M(Polarity +,- common)

20 pin connector x 2(option : NX70-CBLDC) Terminal Block Interface (M3.0).20PTerminal Block Interface (M3.0).20P

16 point

Below 10mA

32 point 16 point

OEMaxNX Series I 31

I/P Unit

Page 32: Oemax Nx Plc

32 I OEMax NX Series

■Characteristics

■External Electrical Schematic Diagram

�16 point, 32 point O/P Unit

�Confirmation of operation by LED Display

�Photocoupler Insulation for all modules

�Connector Type (32 point) can get much

larger I/O numbers per each area.

Caution TTThe numbers (1~20) in the below diagram(NX70-Y32T) indicate the numbers printed

on the front side of the product.

16 point Type

O/P Unit

32 point Type

O/P Unit

■O/P Unit Specification

O/P Point

Insulation Method

Rated Pressure Voltage

Operating Pressure V. Range

Max. Pressure Current

Internal Operating Current(5V)

Surge Killer

Fuse Rating

COMMON Method

RUN Display

External Interface Method

RespondingTime

OFF→ON

ON→OFF

O/P TypeTransistor O/P

NPN Type PNP TypeSSR O/PRelay O/P

NX70-Y16T NX70-Y32T NX70-Y32P

16 point

12V~24V DC

10V~30V DC

0.6A/point 1A/COM

120mA

8 point/COM

Terminal Block(M3.0)

NX70-Y16R NX70-Y16RV NX70-Y16SSR

16 points

250V AC, 30V DC

85~264V AC, 10~30V DC

1A/point 3A/COM

Below 10ms

Below 10ms

120mA 120mA

N/A Varistor

8 point/COM

16 points

SSR

100V~240V AC

85V~264V AC

0.5A/point 2A/COM

Below 1ms

0.5CYCLE + Below 1ms

250mA

N/A

3.0A

3.0A

32 point

12V~24V DC

10V~30V DC

0.4A/point 1A/COM

180mA

20pin Connectorx2 (Option:NX70-CBLTR)

16p/COM(+)16p/COM(-)

Photocoupler

Zener Diode

Terminal Block (M3.0)

Product Code

NX70-Y16TNX70-Y32TNX70-Y32P

NX70-Y16RNX70-Y16RV NX70-Y16SSR

AC100~240V

C

E

O/P Unit

N/A

LED Display

Below 1ms

Below 1ms

Page 33: Oemax Nx Plc

OEMaxNX Series I 33

■I/O Combined Unit Specification

I/O Point

Insulation Method

Rated I/P Voltage

Operating Voltage Range

Max. I/P Current

Rated Operating Current/Voltage

ON Vol. / ON Cur.

OFF Vol. / OFF Cur.

I/P Impedance

Ext. PWR Supply

Internal Operating Voltage(5V)

COMMON Method

I/O Points Occupied

Operation Display

External Line Interface Method

Responding

Time

OFF→ON

ON→OFF

DC Input/RELAY Output Combined Unit DC Input/TR Output Combined Unit

NX70-XY16 NX70-XY32

Product Name

Product CodeI/P 8 p (DC IN)

Photocoupler

12~24V DC

10.2~26.4V DC

Below 10mA

-

Blw 9.6V/Blw 4mA

Blw2.5V/Blw1.5mA

Approx. 3KΩ

Unnecessary

Below 2.0ms

Below 2.0ms

Below 80mA

8p/1COM(Polarity+,- Common)

32p Allocation, I/P 16p, O/P 16p

LED Display

Terminal Block (M3.0)

O/P 8 p (Relay Out)

-

250V AC, 30V DC

-

250V AC, 30V DC, 1A/p

-

-

-

Blw 24V 200mA

Below 10ms

Below 10ms

8p/1COM

I/P 16 p (DC IN)

12~24V DC

10.2~26.4V DC

Below 10mA

-

Blw 9.6V/Blw 4mA

Blw2.5V/Blw1.5mA

Approx. 3KΩ

Unnecessary

Below 2.0ms

Below 2.0ms

Below 120mA

8p/1COM(Polarity+,- Common)

32p Allocation, I/P 16p, O/P 16p

LED Display

220pin ConnectorX2(Option:I/P=NX70-CBLDC,O/P=NX70-CBLTR)

O/P 16 p (TR OUT,NPN)

-

10V~30V DC

-

10V~30V DC, 0.4A/p

-

-

-

-

Below 10ms

Below 10ms

16p/1COM(-), Sync.

■Characteristics

�NX70-XY16 : DCIN 8 P/ Relay OUT 8 P

�NX70-XY32 : DCIN 16 P/ TR OUT 16 P

�DC I/P Type is able to use both +, -COMMON

�Confirmation of operation by LED Display

�Photocoupler Insulation for all modules

(NX70-XY32) DC IN 16 p

TR OUT 16 p

Combined Unit

(NX70-XY16) DC IN 8 p

Relay OUT 8 p

Combined Unit

I/P 16p (DC Input) O/P 16p (TR Output)

■ Internal Circuit and External Electrical Schematic Diagram Caution The numbers (1~20) in the below diagram(NX70-XY32)

indicate the numbers printed on the front side of the product.

NX70-XY16 NX70-XY32

I/O Combined Unit

Page 34: Oemax Nx Plc

34 I OEMax NX Series

Page 35: Oemax Nx Plc

NX700 / N

X70 Series Special Module

An

alo

g, H

SC

, Po

sitio

nin

g, C

om

mu

nic

atio

n, N

etw

ork

, So

ftware

Refer to the attached

NX70 NX700

HSC 1CH HSC 2CHHSC 1CH HSC 2CH HSC 4CHHSC 4CH

POSI1 POSI3 POSI4POSI2POSI4POSI2

CCUCCU CCU +CCU + SCUSCU

Remote Master

DeviceNetMaster

Field bus

RemoteSystem

Network

SerialCommunication

PulseControl PositionControl

High SpeedCounter

TemperatureControl

(RTD,TC)

AnalogI/O

TC 8CH TC 4CHTC 4CHRTD 4CH RTD 8CH RTD 4CH

MW-LINK

Pulse 4 / HSC4Pulse 4 / HSC4

EtherNetMW-LINK

Remote SlaveRemote Slave

D/A 2CH D/A 4CH D/A 8CHD/A 4CHA/D 8CHA/D 4CH

Special Function Modules

OEMaxNX Series I 35

DeviceNetSlave

Page 36: Oemax Nx Plc

36 I OEMax NX Series

■Characteristics

■Performance Specification

Analog I/P Range

Digital Conversion

Converter Type

Characteristics of I/O *1

Max. Resolution Capacity *1

Overall Accuracy

Conversion Speed

External I/P Imped.

Absolute Max. I/P

Insulation Method

I/O Points Occupied

Other Functions

Internal Operating Current (5V)

External Interface Method

Voltage: 0�10V, 0�5V, ±10V, ±5V

16 BIT Binary with sign (Complement of 2)

16BIT A/D Converter

0~10V(0~32767), (0~20000), (0~16383)..

0�5V(0�32767), (0~20000), (0~16383)..

±10V(-32767�32767), (-20000�20000)....

±5V(-32767�32767), (-20000�20000)....

0.153mV, (0.305mV), ........

±0.2%/ F.S (25℃)

1.25ms/ CH

500kΩ

Voltage: ±15V, Current: ±30mA

�Between I/P CH and Internal Circuit: DC/DC Converter, Photocoupler Insulation �Between I/P CH and I/P CH: No Insulation

�I/O Interface Method �Shared Memory Method

CH Conversion ON/ OFF Function

�NX70: Below 5V 290mA, External Power 24VDC Unnecessary �NX700: Below5V 270mA

�NX70: 20pin Terminal Block Interface (M3.0) �NX700: 20pin Detachable Terminal Block Interface (M3.5)

Current : 0�20mA, 4�20mA, ±20mA

0.519uA, (0.61uA), ......

±0.3%/ F.S (25℃)

249Ω

Voltage: ±7.5V, Current:±30mA

0~20mA(0~32767), (0~20000), (0~16383)..

4�20mA(0�32767), (0~20000), (0~16383)..

±20mA(-32767~32767), (-20000�20000)....

NX700 A/D Unit NX70 A/D Unit

1) Application Command〔READ〕reading method

2) I/P Interface reading method

Fill in with Application Command〔WRITE〕.

�Diverse Data Process Method emperature, speed, pressure, Flux

Q’ty Electricity(Voltage,Current, Electric Power,Frequency)

Each type of Sensors

Displacement Sensor

Instrumentation

Transducer

Sensor

MQ Laser Sensor, DSA Displacement Sensor, etc.

Deviation can be adjusted without separate volume. Especially,

conversion speed and resolution that decide diverse analog I/P

range and performance were processed to high speed and high

accuracy.

1. NX70 A/D Module

NX700 A/D Module

2. Drastically improved Resolution

The level of Resolution is max. 0.153mV with Voltage Type and

0.519uA with Current Type. (Resolution can be selected in

accordance with Dip S/W of module)

3. DC/DC and Photocoupler Insulation between Channels

4. Diverse Data Process Method

There are two methods available for Analog Data Process and

Address Designation①by way of Shared Memory

②by way of I/O Interface, which can be conveniently selected to

fit for purposes to use.

5. High Speed Process

By adopting 16bit A/D Converter, process is done with high

accuracy conversion Data, as well as with the high speed of

1.25ms/CH.

NX70-AI8V (Voltage I/P), 8CH

NX70-AI4V (Voltage I/P), 4CH

NX-AI8V (Voltage I/P), 8CH

NX70-AI8C (Current I/P), 8CH

NX70-AI4C (Current I/P), 4CH

NX-AI8C (Current I/P), 8CH

NX70 Series

NX700 Series

Analog I/P Unit(A/D)

*1. Up to high resolution and general resolution can be selected with regard to I/O characteristics and maximum resolution, which can be selected according to Dip S/W under the product.

Stability of conversion speed and conversion data is different according to the resolution. (Refer to the Manual for details.)

*2. It is recommended that the number of D/A modules on the motherboard to be min. below 8 EA. (There is restriction in operating current when the channels operate simultaneously even though there

is no problem in mounting.)

Page 37: Oemax Nx Plc

OEMaxNX Series I 37

*1.Up to high resolution and general resolution can be selected with regard to I/O characteristics and maximum resolution, which can be selected according to Dip S/W under the product.

Stability of conversion speed and conversion data is different according to the resolution. (Refer to the Manual for details.)

*2. It is recommended that the number of D/A modules on the motherboard to be min. below 8 EA. (There is restriction in operating current when the channels operate simultaneously even though

there is no problem in mounting.)

■Characteristics

■Performance Specification

Analog O/P

No. of Analog O/P CH

Digital Conversion

Converter Type

Characteristics Of I/O *1

Max. Resolution Capacity *1

Overall Accuracy

Conversion Speed

O/P Impedance

O/P Allowable Load Resistance

Insulation Method

I/O Points Occupied

Internal Operating Current(5V)

*2

External Interface Method

±10V, 0�10V, ±5V, 0�5V

2 CH 4 CH 4 CH 8 CH

16 BIT Binary with sign (Complement of 2)

14BIT D/A Converter

1) ±10V (-16,383�16,383), (-10,000�10,000)

2) 0�10V (0�16,383), (-0�10,000)

3) ±5V (-16,383�16,383), (-10,000�10,000)

4) 0�5V (0�16,383), (-0�10,000)

0.6mV (0.305mV, 0.5mV, 1mV)

±0.2%/ F.S (25℃)

2.5ms / CH

Below 0.1Ω

Above 5KΩ

�Between O/P CH and Internal Circuit: DC/DC Converter, Photocoupler Insulation �Between O/P CH and O/P CH: No Insulation

�I/O Interface Method, 8CH:128p O/P, 4CH:64p O/P, 2CH:32p O/P �Shard Memory Method:16p

Below 5V 230mA (D/A O/P:80mA/ CH)

Below5V 380mA (D/A O/P: 20mA/ CH)

Below 5V 500mA (D/A O/P: 20mA/ CH)

Below 5V900mA

(D/A O/P: 20mA/ CH)

Below 5V 310mA(D/A O/P:80mA/ CH)

Below 5V 700mA (D/A O/P: 20mA/ CH)

�NX70 : 20 pin Terminal Block Interface (M3.0) �NX700 : 20 pin Detachable Terminal Block Interface (M3.5)

0�20mA, 4�20mA

2 CH 4 CH 4 CH 8 CH

1.2uA (1.037uA, 1.7uA, 2uA)

±0.4%/ F.S (25℃)

Above 10Ω

Below 500Ω

1) 0�20mA (0�16,383), (-0�10,000)

2) 4�20mA (0�16,383), (-0�10,000)

Deviation can be adjusted without separate volume. Especially,

conversion speed and resolution that decide diverse analog I/P

range and performance were processed to high speed and high

accuracy.

1. NX70 D/A Module

NX700 D/A Module

2. DC/DC Insulation between Channels and Internal Circuits

3. Drastically improved Resolution

The level of Resolution is max. 0.153mV with Voltage Type and

0.519uA with Current Type.

4. Diverse Data Process Method

There are two methods available for Analog Data Process and

Address Designation ①by way of Shared Memory

②by way of I/O Interface, which can be conveniently selected to

fit for purposes to use.

5. High Speed Process

By adopting 14bit D/A Converter, process is done with high

accuracy conversion Data, as well as with the high speed of

1.25ms/CH.

NX70 NX700

NX70-AO2V NX70-AO4V NX-AO4V NX-AO8V

Voltage O/P

Product Code NX70 NX700

NX70-AO2C NX70-AO4C NX-AO4C NX-AO8C

Current O/P

�NX700 D/A Unit �NX70 D/A Unit

�Diverse Data Process Method

1) Application Command[WRT〕filling in Method

2) I/P Interface I/P Method

Read by writing Appl. Command〔READ〕

Inverter

M

Speed Control of the Motor

Temperature Recorder

Analog O/P Unit(D/A)

Page 38: Oemax Nx Plc

38 I OEMax NX Series

■Characteristics

High speed and high accuracy process is enabled by adopting 24bit Σ-

ΔA/D converter and has diverse I/O range and self calibration function.

1. NX70 RTD Module

NX700 RTD Module

2. Types of Temperature Sensor

Temperature Sensor available for use is 3 line typed Platinum

sensor.(Pt100, Pt200, Jpt100, Jpt200......)

3. All Celsius(℃)Data and Fahrenheit(℉) Data can be used

Can be selected according to the DIP switch placed under the unit.

4. Diverse Data Process Method

There are two methods available for Analog Data Process and

Address Designation①by way of Shared Memory ②by way of

I/O Interface, which can be conveniently selected to fit for

purposes to use.

5. Design Specification resistant to NOISE

Analog & Digital Noise Filter is designed to be attached inside of

the unit in order to resist interference from the external

environment.

NX700 RTD Unit NX70 RTD Unit

1) Application Command〔READ〕reading method

2) I/P Interface reading method

※RTD: Resistance Temperature Detectors

3 Line Type RTD Sensor (Pt100, JPt100, Pt200, JPt200,...)

-200~660℃-200~510℃

�Diverse Data Process Method

※RTD: Resistance Temperature Detector Utilize the

principle that resistance value varies according to change

of temperature. Measure voltage by sending rated

current to the changing resistance. V=I*R

■Performance Specification

RTD Sensor

RTD I/P CH Numbers

Digital Conversion

Converter Type

Max. Resolution Capacity

Overall Accuracy

Conversion Speed

External I/P Impedance

Current Source

Insulation Method

Internal Operating Current(5V)

External Interface Method

3-Wire Method

8 CH

16 BIT Binary with symbol (Complement of 2)

24BIT Σ-ΔA/D Converter

4 CH

①Pt100 (α=0.00385, -200�650℃=> -2,000�6,500 ⑤300Ω(10mΩ/ BIT)

②Pt200, Pt500, Pt1000 ⑥600Ω(20mΩ/ BIT)

③JPt100 (α=0.00385, -200�600℃=> -2,000�6,000) ⑦2000Ω(100mΩ/ BIT)

④Jpt200, Jpt500, Jpt1000 ⑧NI100, NI120, CU10

�I/O Interface Method: 128 p I/P �I/O Interface Method:64 p I/P,

�Shared Memory Method:16 p I/P �Shared Memory Method:16 p I/P

Characteristics of I/O(Applicable TemperatureSensor & Digital O/P)

I/O Points Occupied

0.1℃, 0.1℉, 10mΩ, 20mΩ

±0.1%/ F.S (25℃)

60ms/ CH

10MΩ

1mA (Excitation Current)

�Between O/P CH and Internal Circuit: DC/DC Converter, Photocoupler Insulation �Between O/P CH and O/P CH: No Insulation

Internal Power Source Below 5V 290mA Internal Pwr Source Blw 5V 280mA

�NX70 : 20 pin Terminal Block Interface (M3.0) �NX700 : 20 pin Detachable Terminal Block Interface (M3.5)

Product CodeNX70-RTD8 (8CH) *to be released

NX-RTD8 (8CH)

NX70

NX700

NX70-RTD4 (4CH)

NX-RTD4 (4CH)

RTD Unit(Resistance Temperature Detector Unit)

Fill in with Application Command〔WRITE〕

Page 39: Oemax Nx Plc

OEMaxNX Series I 39

■Characteristics

NX700 TC Unit NX70 TC Unit

High speed and high accuracy process is enabled by adopting 24bit Σ-

ΔA/D converter and has diverse I/O range and self calibration function.

1. NX70 TC Module

NX700 TC Module

2. Types of Temperature Sensor

Temperature Sensor types available for use are B, R, S, N, K, E,

J, T, L, U, C, D.

3. All Celsius(℃)Data and Fahrenheit(℉) Data can be used

Can be selected according to the DIP switch placed under the unit.

4. Diverse Data Process Method

There are two methods available for Analog Data Process and

Address Designation; ① by way of Shared Memory ② by way of

I/O Interface, which can be conveniently selected to fit for

purposes to use.

5. TC Unit provides Temperature Compensation Function

Temperature compensation due to difference of temperatures

between the actual measuring point and unit is required when

ThermoCcouple is connected to the Unit. Accordingly, this Unit

has embedded the temperature sensor in the unit to

compensate this.

※TC: ThermoCouple

1) Application Command〔READ〕reading method

2) I/P Interface reading method

+

-

Sensor Type B,R,S,N,K,E,J,T,L,U,C,D

Temperature range varies

according to Sensor Types

�Diverse Data Process Method

■Performance Specification

Digital Conversion

TC Input CH

Converter Type

Max. Resolution Capacity

Overall Accuracy

Conversion Speed

External I/P Impedance

Temperature Compensation Sensor

Insulation Method

External Interface Method

16 BIT Binary with symbol (Complement of 2)

8 CH

24BIT Σ-ΔA/D Converter

4 CH

Type B/ R/ S/ N/ K/ E/ J/ T/ L/ U/ C/ D(Temperature range varies according to sensor types)

±30mV (1uV/ BIT)

±60mV (2uV/ BIT) ±78.0mV (10uV/ BIT)

�I/O Interface Method: 128 p I/P �I/O Interface Method:64 p I/P,

�Shared Memory Method:16 p I/P �Shared Memory Method:16 p I/P

Characteristics of I/O

(Applicable Temperature

Sensor & Digital O/P)

I/O Points Occupied

Internal Operating Current(5V)

0.1℃, 0.1℉, 10mΩ, 20mΩ

±0.1%/ F.S (25℃)

60ms/ CH

10MΩ

1mA (Excitation Current)

�Between I/P CH and Internal Circuit: DC/DC Converter, Photocoupler Insulation �Between I/P CH and I/P CH: No Insulation

Internal Power Source Below 5V 290mA Internal Power Source Below 5V 280mA

�NX70 : 20 pin Terminal Block Interface (M3.0) �NX700 : 20 pin Detachable Terminal Block Interface (M3.5)

Product CodeNX70-TC8 (8CH) to be released

NX-TC8 (8CH)

NX70-TC4(4CH)

NX-TC8 (4CH)

TC(ThermoCouple) Unit

Fill in with Application Command〔WRITE〕

NX70

NX700

Page 40: Oemax Nx Plc

40 I OEMax NX Series

■Performance Specification

I/P Point

I/P Voltage

ON Voltage/Current

OFF Voltage/Current

No. of Counter Channels

Range of Factors

Max. Factor Speed

I/P Mode

Min. I/P Pulse width

Multiplying Function

Insulation Method

O/P Mode

Rated Operating Volt.

Max. Load Current

Residual Voltage

Leakage Current

O/P Point

O/P Frequency

Low Frequency

High Frequency

Conversion Time

Up/Down Time

O/P Point

Common Terminal

Fuse

Response Time

I/O Points Occupied

Operation Display

External Interface Method

3p,(INA, INB, PR/INH)

5 ~ 24V DC

Below 4.5V / Below 3mA

Above1.5V / Above 0.6mA

1 CH (UP-DOWN Counter)

24 bit sign available(Binary Type) (-16,777,216~16,777,215)

100Kcps

3 mode {Phase Difference I/P(1 multiplying, 4 multiplying), Direction Discrimination: Pulse + Direction, Individual I/P: CW, CCW}

5us (in case of Individual I/P Mode)

1 Multiplying,4 Multiplying (in case of Phase Difference I/P Mode)

Photocoupler

Transistor O/P (NPN, Open Collector)

5 ~ 24V

50mA

Below 0.5V

Below 10uA

2p, (C=P, C>P)

2p / COMMON

N/A

OFF →ON :Below10us, ON →OFF :Below100us

2words(32p, I/P 16p, O/P 16p)

LED Display

�NX70 :20pin T/Block Interface (Terminal Screw, M3.0) �NX700 : 20 pin Detachable T/Block Interface(T/Screw, M3.5)

�NX-Series: Process Data READ/WRITE with Application Command F150, F151 Command

�NXplus -Series: Process High Speed Counter Data with Application Command READ/WRITE

6p, ( INA, INB, PR/INH) x 2

2 CH (UP-DOWN Counter)

4p, (C=P, C>P) x 2

6p, ( INA, INB, RST, INH, ZERO, SUB )

1 CH (UP-DOWN Counter)

2points (OUT0, OUT1)

200 ~ 40kHz : Duty 50% ±25%, Variation ±5%

200 ~ 5kHz

4k ~ 40kHz

100 ~ 500ms

Below 2us

2p, (C=P, C>P)

Function N/A

Counter

Spec.

Common

O/P

SpecPulse

O/P

(OUT0,

OUT1)

ControlO/P

(C=P, C>P)

Others

High Speed Counter DataRead/ Write

I/P Spec.

Product

Code

NX70-HSC1

-

NX70

NX700

-

NX-HSC1

NX70-HSC2

NX-HSC2

As a High Speed Counter with 100Kcps high speed response, monitor and data set-up for the contents of counter is simple and easy.

(NX70-HSC1: High speed counter function and simple pulse O/P function, NX70-HSC2, NX-HSC1, NX-HSC2 : High speed counter function only)

NX700 HSC Unit NX70 HSC Unit

■Characteristics

2. 100Kcps high speed response and wide value I/P response of 100kcps enabled. The range of value has 24 bit sign (binary)

and covers -16,777,216~ 16,777,215.

3. Monitoring the contents of counter and data set-up is easy With shared memory, random data READ and Write can be done against

PLC.

4. Compared O/P, Corresponding O/P, etc., are available (C=P, C>P) Can be used as deceleration or pause signal during motor control.

5. Simplified Pulse O/P enabled (NX70-HSC1 Module only) Pulse O/P for control of pulse motor and servo motor is available and able to

adjust and two-step converse between max. frequency (40KHZ) and min.

frequency(200HZ). Accordingly, simple motor control and positioning control

can be done by combination of pulse and servo motor. Time setting for

conversion from high to low frequency can be done with the external volume

control.

1. Diverse Counter I/P Mode can be selectedAble to correspond to Phase Difference I/P mode that can count 2-phase

pulse of encoder, to individual I/P mode which is CW and CCW I/P mode

and to direction discrimination mode. (DIP SWITCH adjustment)

High Speed Counter Unit(HSC1,2)

Page 41: Oemax Nx Plc

OEMaxNX Series I 41

■Examples of Application using High Speed Counter(HSC)

Read Data with Appl. Command(READ)

Read Data with Appl. Command(READ)

(HSC Function)

Motor

EncoderRead Data with Appl. Command(READ)

Write down Data with Appl. Command(WRT)HSC

Inverter

E

O/P at Encoder to be I/P I/P of O/P fromEncoder with HSC Phase Difference I/P Mode

C=P Conversion I/P

C>P Pause I/P

M

Example of Counting RPM at Encoder O/P and compare with RPM at Setup

Example of configurating controls of motor driver with 2 pulse O/P and by counting RPM of motor

�NX700 :NX-HSC1 Unit

NX-HSC2 Unit

�NX70 :NX70-HSC 1Unit

NX70-HSC 2Unit

HSC

(Pulse O/P Function)

�NX70 : NX70 : Applicable to NX70-HSC1 Unit only

Motor Driver

P.OUT 1

P.OUT 2 R/V I/P

F/V I/P

Motor

Encoder O/P

X-Y Table

INA

INB

Page 42: Oemax Nx Plc

42 I OEMax NX Series

�NX700 : NX-CPU750A/ B/ C/ D, 700P Unit �NX70 : can be used with NX70-CPU750, CPU70 P2 Unit only

HSC 4CH with high speed response of 200Kcps mounted. Range of Coefficient is 32 Bit with functions of HSC 4CH, Interrupt

I/P 8 and comparative O/P 8 point. In addition, unused interface can be used with common I/O 32 points.

High performance High Speed Counter(4CH) Units are

■Characteristics

1. High Speed Response with HSC 200K count/s

Enabled precision control with embedded 4CH of HSC I/P with

max. 200kHz.

2. Wide ranged Coefficient Value(32 bit with symbol attached)

Coefficient range is with 32 bit sign(binary) that covers the range

of -2,147,483,648 ~ +2,147,483,647.

3. I/P Time Constant Function to prevent Noise-related Count

due to I/P of Noise

Sensitivity can be changed by using the I/P Time Constant

Function in order to prevent mis-counting due to noise.

(4, 8, 16, 32 /us)

4. Compared O/P Interface 8 points embedded

High performance HSC(4CH) has embedded 8 points of O/P

allotted randomly. Fractions of Counter is changeable. Can be

used at change of speed or pause signal when controlling the

motor by inverter.

5. Interrupt I/P 8 points embedded

Interrupt program can be activated when the Elapsed Value

conforms or in accordance with the timing of external I/P signal.

Control with out delay or disorder can be done when any

malfunction occurs at the device operating at high speed.

6. Conventional I/O Function(I/O combined 32 points)

Operates as a 16 IN/16 OUT I/O Combined Unit at the initial

stage when operation of mode setup switch or shared memory

setup are not made. I/O of other functions precedes when using

other functions but the part without function allotment can be

used as I/O.

7. Enables High-Efficiency System Configuration

With one unit of high performance HSC module, HSC, Interrupt,

Compared O/P and conventional I/O functions are all mounted

so that economic system configuration can be done.

8. Enables Selection of Diverse Counter I/P Mode

Able to respond to the phase difference I/P mode that can count

2 phase pulse of rotary encode and direction discrimination

mode, and the separate I/P mode that are CW and CCW I/P.

High Speed Counter(4CH) Count RPM at Encoder O/P and comparewith RPM at Setup so as to direct Conversionand Pause, etc., by Inverter

High Performance HSCunit for NX700 PLC(NX70-HSC4)

For NX70 PLCHigh Performance HSC Unit (NX70-HSC4)

High Performance High Speed Counter(4CH)

Read Data with Appl. Command(READ)

motor

EncoderWrite down Data with Appl. Command(WRT)

Inverter

E

O/P at Encoder to be I/PI/P of O/P from Encoder with HSC Phase Difference I/P Mode

C=P Conversion I/P

C>P Pause I/P

M

Page 43: Oemax Nx Plc

OEMaxNX Series I 43

■Performance Specification

Insulation Method

Rated I/P Voltage

Rated I/P Current

I/P Impedance

Operating Voltage Range

Min. ON Vol. / ON Cur.

Max. OFF Vol./ OFF Cur.

I/PTime Constant Setup *1

Common Method

No. of Counter Channels

Coefficient Range

Speed of Max. Coefficient *1

I/P Mode

Min. I/P Pulse Width *1

Multiply Function

Others

Interrupt Point *2

Interrupt Process Delay

Insulation Method

Rated Load Voltage

Rated Load Voltage Range

Max. Load Current

Leakage Current on OFF

Max. Voltage Drop on ON

Photocoupler Insulation

24V DC

Approx. 7.5mA (when 24V DC is used)

Approx. 3.2 kΩ

20.4V DC �26.4V DC

19.2V / 6mA

5.0V / 1.5mA

Below 1us

Below 2us

N/A, 4us, 8us, 16us, 32us (2 I/P Unit Setup)

16 points/ COM

4 CH

32bit sign attached ( -2,147,483,648 ~ +2,147,483,647 )

200kHz

3 Mode(Phase difference I/P mode, Direction Discrimination mode: Pulse + Direction, Separate I/P mode : CW, CCW )

2.5us

1 Multiply, 2 Multiply, 4 Multiply

Compared O/P 8 points

N/A, 1p/Unit, 8p/Unit (according to mode setup switch)

Below 160 us (when using NX-CPU750A, CPU750B)

below50 us (when using NX-CPU750C, CPU750D)

Photocoupler Insulation

5V DC �24V DC

4.75V DC �26.4V DC

0.1A (A11~A18, B11~B14 Terminal Block),

0.8A (B15~B18 Terminal Block)

Below 1uA

Below 0.5V

Below 1us

Below 1us

Zener Diode

16 p / Common

20.4V DC �26.4V DC

Below 90mA

8 p (A11 ~ A18 Terminal Block)

40 pin Connector x 1 EA

Below 160 us

0.1A (【Ⅱ】A1�A8,【Ⅱ】B1�B4 Terminal Block),

0.8A (【Ⅱ】B5�B8 Terminal Block)

8 p (【Ⅱ】A1 ~ A18 Terminal Block)

20 pin Connector x 2 EA

Counter

Interrupt

O/P

Spec.

Counter

External Power

Supply

Response

Time

Compared O/P

Surge Killer

Common Method

External Terminal Block Interface

Spec.

of

I/P

Product CodeFor NX70 PLC

NX70-HCS4

For NX700 PLC

NX-HSC4

Response

Time

OFF →ON

ON →OFF

OFF →ON

ON →OFF

Voltage

Current(when 24V DC is used)

*1. The Value is when I/O Time Constant (filter) Setup is not available. *2. When using interrupt with 1 point/ unit setup, in case of NX700, interrupt from the external I/P terminal block B1(X8) or interrupt program (one of INT16.INT23) from

compared 0 will be activated.

Page 44: Oemax Nx Plc

44 I OEMax NX Series

�NX700 : NX-CPU750A/ B/ C/ D, 700P Unit �NX70 :can be used on NX70-CPU750, CPU70P2

Have 4LOOP pulse O/P and HSC embedded at the same time together with all functions of high performance HSC (NX-

HSC4)(200Kcps HSC 4CH mounted, coefficient range 32 bit, Interrupt I/P 8 point, Compared O/P 8 point and Common I/O 32

points). In addition, 100KHz pulse O/P 4CH or 40KHz PWM O/P 4CH can be used.

Pulse I/O Unit(4CH)

For NX700 PLCHigh performance Pulse I/O Unit(NX-PULSE4)

For NX70 PLCHigh performance Pulse I/O Uni(NX70-PULSE4)

■HSC Function (4CH)

PWM O/P . 30KHz O/P(1Hz Unit) . Duty : 0 ~ 100%

Servo& SteppingMotor Drive

Servo & SteppingMotor

Pulse O//P1)Direction Discrimination(pulse+direction) 2)Separated O/P(CW, CCW)

■Pulse O/P Function(4CH)

■Characteristics

1. Pulse O/P, 100KHz 4CH

Maximum Pulse O/P is 100kHz and have 2 types of O/P mode

(Direction Discrimination O/P: Pulse + Direction, Separate O/P: CW,

CCW). O/P frequency can be setup by 1 Hz units and high speed

process is enabled because that I/P setup can be done with high

speed counter by internal interface of unit.

2. PWM O/P, 30KHz 4CH

Maximum 30KHz of PWM O/P can be done and Duty ratio can be

setup by 1 % units from 0 to 100%.

3. High Speed Counter 200KHz 4CH

Precision control is enabled with the embedded 4CH of maximum

200kHz high speed I/P.

4. Wide ranged Coefficient Value(32 bit with symbol attached)

Coefficient range is with 32 bit sign(binary) that covers the range of -

2,147,483,648 ~ +2,147,483,647.

5. I/P Time Constant Function to prevent Noise-related Count due

to I/P of Noise

Sensitivity can be changed by using the I/P Time Constant Function

in order to prevent mis-counting due to noise. (4, 8, 16, 32 /us)

6. Compared O/P Interface 8 points embedded

Pulse I/O Unit has embedded 8 points of O/P allotted randomly.

Fractions of Counter is changeable. Can be used at change of

speed or pause signal when controlling the motor by inverter.

7. Interrupt I/P 8 points embedded

Interrupt program can be activated when the Elapsed Value

conforms or in accordance with the timing of external I/P signal.

Control with out delay or disorder can be done when any malfunction

occurs at the device operating at high speed.

8. Conventional I/O Function (I/O combined 32 points)

Operates as a 16 IN/16 OUT I/O Combined Unit at the initial stage

when operation of mode setup switch or shared memory setup are

not made. I/O of other functions precedes when using other

functions but the part without function allotment can be used as I/O.

9. Enables High-Efficiency System Configuration

With one unit of Pulse I/O, HSC, Interrupt, Compared O/P and

conventional I/O functions are all mounted so that economic system

configuration can be done. .

Pulse I/O Unit(4CH)

Read Data with Appl. Command(READ)

Motor

EncoderRead Data with Appl. Command(READ)

Inverter

EO/P at Encoder to be I/P

C=P Conversion I/P

C>P Pause I/P

M

Read Data with Appl. Command(READ)

Write down Data with Appl. Command(WRT)

Page 45: Oemax Nx Plc

OEMaxNX Series I 45

■Performance Specification

Insulation Method

Rated I/P Voltage

Rated I/P Current

I/P Impedance

Operating Voltage Range

Min. ON Vol. / ON Cur.

Max. OFF Vol./ OFF Cur.

I/PTime Constant Setup *1

Common Method

No. of Counter Channels

Coefficient Range

Speed of Max. Coefficient *1

I/P Mode

Min. I/P Pulse Width *1

Multiply Function

Others

Interrupt Point *2

Interrupt Process Delay

Insulation Method

Rated Load Voltage

Rated Load Voltage Range

Max. Load Current

Leakage Current on OFF

Max. Voltage Drop on ON

No. of Channels

Max. O/P Frequency

O/P Mode

No. of Channels

Max. Load Current

Cycle

Duty

*3

*3

*3

Photocoupler Insulation

24V DC

Approx. 7.5mA (when 24V DC is used)

Approx. 3.2 kΩ

20.4V DC �26.4V DC

19.2V / 6mA

5.0V / 1.5mA

Below 1us

Below 2us

N/A, 4us, 8us, 16us, 32us (2 I/P Unit Setup)

16 points/ COM

4 CH

32bit sign attached ( -2,147,483,648 ~ +2,147,483,647 )

200kHz

3 Mode(Phase difference I/P mode, Direction Discrimination mode: Pulse + Direction, Separate I/P mode : CW, CCW )

2.5us

1 Multiply, 2 Multiply, 4 Multiply

Compared O/P 8 points

N/A, 1p/Unit, 8p/Unit (according to mode setup switch)

Below 160 us (when using NX-CPU750A, CPU750B)

below50 us (when using NX-CPU750C, CPU750D)

Photocoupler Insulation

5V DC �24V DC

4.75V DC �26.4V DC

0.1A (A11~A18, B11~B14 Terminal Block),

0.8A (B15~B18 Terminal Block)

Below 1uA

Below 0.5V

Below 1us

Below 1us

Zener Diode

16 p / Common

20.4V DC �26.4V DC

Below 90mA

8 p (A11 ~ A18 Terminal Block)

40 pin Connector x 1 EA

4CH(B11 ~ B18 T/B)

100KHz

2 Mode (Direction Discrimination O/P: Pulse + Direction, Separate O/P: CW, CCW )

4CH (B15 . B18 T/B)

0.8 A

1Hz �30KHz (1Hz Unit)

0 �100% (1% Unit)

Below 160 us

0.1A (【Ⅱ】A1�A8,【Ⅱ】B1�B4 Terminal Block),

0.8A (【Ⅱ】B5�B8 Terminal Block)

8 p (A11 ~ A18 Terminal Block)

20 pin Connector x 2 EA

4CH ( 【Ⅱ】B1 �B8 T/B)

4CH (B15 . B18 T/B)

Counter

Interrupt

O/P

Spec.

Counter

Pulse

O/P

PWM

O/P

External Power

Supply

Response

Time

Compared O/P

Surge Killer

Common Method

External Terminal Block Interface

Spec.

of

I/P

Product CodeFor NX70 PLC

NX70-PULSE4

For NX700 PLC

NX-PULSE4

Response

Time

OFF →ON

ON →OFF

OFF →ON

ON →OFF

Voltage

Current(when 24V DC is used)

*1. The Value is when I/O Time Constant (filter) Setup is not available.

*2. When using interrupt with 1 point/ unit setup, in case of NX700, interrupt from the external I/P terminal block B1(X8) or interrupt program (one of INT16.INT23) from

compared 0 will be activated.

*3. At maximum load current and resistance load, there may be distortion at O/P waveform according to load current or type of load.

Page 46: Oemax Nx Plc

46 I OEMax NX Series

1 Axis, 2 Axis, 3 Axis, 4 Axis Unit. Enabled high speed, high accuracy positioning with Speed Command Maximum 1Mpps. Have linear

interpolation, circular interpolation function and able to realize smooth activation/pause with s-shaped acceleration/deceleration

function. In addition, real time O/P was enabled by manual pulse generator with pulse generator I/P function.

1 axis unit (NX-POSI1)

3 axis unit (NX-POSI3)

4 axis unit (NX-POSI4)

(NX70-POSI4)

2 axis unit (NX-POSI2)

(NX70-POSI2)

■Kinds of Product ■Characteristics

1. High speed, high accuracy positioning was enabledwithmaximum 1M pulse/s of pulse speed.

2. Multi axis control was enabled by mounting 4 axes in 1unit.

3. Made Tact-Time reduction possible with high speed activationtime (activation time 0.1ms) Tact-Time can be reduced by selecting high speed activation mode.

4. Parameter setup was simplified and automatic acceleration/deceleration was enabled with data setup.

5. Smooth activation/pause was realized with s-shapedacceleration/deceleration function

6. Able to select Pulse O/P Method (Open Collector or Line Drive) Able to respond through interface with pulse I/P method drive

(AC/DC servo drive, stepping drive). This positioning unit can

interface with any kind of drive because it can select and use

Open Collector O/P or Line Drive O/P.

7. Real time O/P was enabled by manual pulse generator with pulsegenerator I/P function.(Max. 1,000 multiply with Multiply Function)

Speed(Pulse/s)

Target Speed 5000

Activation Speed100

No. of O/P Pulse 100000

Acc/Deceleration Time200ms

t(ms)

■Kinds of Product

(Pulse Train I/P TYPE) �Servo Drive �Stepping Drive

�Servo Motor �Stepping Motor

Motor

Drive1Axis 3Axis 4Axis 2Axis

Positioning Unit �NX700 : NX-CPU750A/ B/ C/ D, 700P Unit �NX70 : can be used on NX70-CPU750, CPU70P2 Unit only.

Positioning Unit

Motor

Motor

Motor

Motor

Page 47: Oemax Nx Plc

OEMaxNX Series I 47

■Performance Specification

Com. Unit

Com.Range

Com. Range

Acc/Dec. Method

Acc/Dec. Time

Return to 0 Point speed

I/P Terminal Block

Occupied I/O Point

Mountable Slot

No. of Control Axes

128 P (I/P 64P, O/P 64P) 64 P (I/P 32P, O/P 32P)

Basic Motherboard (extended motherboard)

Pulse Unit (Increment, Absolute) is commanded by program

Sign attached 32 bit (-2,147,483,648 ~+2,147,483,647 pulse)

�When Line Drive is used: 1pulse/s ~ 1M pulse/s

�When Open Collector is used: 1pulse/s ~ 200K pulse/s

(setup can be done by 1pps unit)

Linear Acc/Deceleration, S-shape Acc/Deceleration

0�32,767ms

Speed setup can be done (return speed, search speed change)

0 Point I/P, Near 0 Point I/P

�E point Control(Linear,S-shaped Acc/Deceleration Select) *1

�P point Control(Linear,S-shaped Acc/Deceleration Select) *1

�Return to 0 Function (Linear,S-shaped Acc/Deceleration Select)

�JOG Drive Function (Linear,S-shaped Acc/Deceleration Select) *1

�Pulse Generator I/P Function (Multiply x1, x2, x5, x10, x50, x100, x500, x1000 can be selected)

Below 0.1ms

Pulse/ Sign Mode, CW/CCW Mode (transfer by DIP S/W)

Deviation Counter Clear Signal O/P Interface

24V DC (21.6 ~ 26.4V DC)

Operation Mode

Activation Time

O/P Mode

Other Functions

External Power Supply *3

PositioningCommand

Independent 4 Axes Independent 3 Axes Independent 2 Axes Independent 1 Axes

Item1Axis Unit

(NX-POSI1)

4Axis Unit

(NX-POSI4)

(NX70-POSI4)

3Axis Unit

(NX-POSI3)

2Axis Unit

(NX-POSI2)

(NX70-POSI2)

SpeedCommand

Return to 0 point

*1. Each E point control and P point control indicate Acc/Deceleration control as shown in the below picture.

*2. Target speed change during RUN can be made if linear acc/deceleration RUN is selected. *3. Power is supplied from the external connector at positioning module.

Speed [pulse/s]

E PointControl

P PointControl

Simple Acc/Deceleration

control moving to END point

Multi Step setup enabled acc/deceleration

control that setup PASS point repeatedly

Time [ms]

Page 48: Oemax Nx Plc

48 I OEMax NX Series

CCU module can not be used with Plus Series. Caution

■Configuration of SECTOCOL-COM Protocol

�Summary for Comments and Functions (SETOCOL)

1. Communication between PLC and Computer can be realized

easily and economically

1:1 or 1:N interface can be achieved with a computer having RS232C

port without specific interface and regardless of type of the

computer. READ/ WRITE of data can be done without complex

system configuration.

2. Communication between PLC↔Computer with SECTOCOL-COM

Communication with computer having RS232C port can be used

according to SECTOCOL-COM format which is a CCU Protocol.

(Example of configuration: %01#RCSX0000IDcr)

3. Communication between PLC(CCU) ↔ Display Panel Device

(TOUCH PANEL)

There is no problem in interfacing because most of the famous

display panel devices (HAKKO, DIGITAL, PATLITE, etc.) have

protocols embedded

4. Operating status of PLC can be supervised or monitored from Computer

Operation status of each kind of Relay(Bit Data) or Register(Word

Data) can be supervised or Data WRITE(I/P) can be done from the

Computer.

5. Modem Transmission enabled

Can be used in long-distance communication by utilizing the

common public lines because this unit responds to HAYES AT

Comment type modem.

6.Any PLC Data configured with NETWORK can function READ/ WRITE

In particular, this unit can display enormous power because that

computer link function against any PLC, that is interfaced with LINK

LOOP(including LINK LOOP1/LINK LOOP2) with the computer linked

with CCU when PLC is configured in Network, can be used. (for more

details, please refer to the CCU Manual「LC(Layer Control

Command)」.)

RCS

WCS

RCP

WCP

RCC

WCC

SC

RD

WD

SD

RS

WS

RK

WK

MC

MD

MG

RR

WR

RT

RM

AB

Interface Information by 1point unit READ

Interface Information by 1point unit Write

Interface Information by multi point unit READ

Interface Information by multi point unit Write

Interface Information by Word Unit READ

Interface Information by Word Unit Write

Word Unit Preset of Interface Area

Data Area READ

Data Area WRITE

Preset of Data Area

PRESET Value Area READ of Timer/Counter

PRESET Value Area Write of Timer/Counter

PASS Value Area READ of Timer/Counter

PASS Value Area Write of Timer/Counter

Register and Unregister of Monitor Interface

Register and Unregister of Monitor Data

Monitoring Start

READ of System Register

Write of System Register

Status READ of PLC

Remote Control (RUN/ PROG Mode Transfer)

Transmission Pause Command

Comment Explanation of contents

NX700 CCU Unit (NX-CCU)

NX70 CCU Unit (NX70-CCU)

* CCU function is available if “COM”ports of CPU750 for NX700 and NX7-CPU750 module are used.

∙MMI S/W∙(C-language, BASIC)

Touch Panel etc

RS232 Cable

Computer

■Performance Specification

Interface

Transmission Speed

Communication Method

Activation Method

Transmission Code

Trans. Data Format

Data Transmission Sequence

Trans.Unit

Max. Length of Message

Trans.Unit

Max. Length of Message

ComputerLink

DataLink

Modem Control

RS232C 1port

300 /600/ 1200/ 2400/ 4800/ 9600 / 19200bps

(with DIP switch under CCU Unit)

FULL DUPLEX Method

START - STOP Method

ASCII

STOP BIT : 1bit / 2bit

Parity : EVEN/ ODD

Length of Data : 7bit / 8bit

End Point Code: Carriage Return (cr) Fix

By Character Unit transmit from bit 0

From Header (%) to Terminator (cr)

Max. 118 letters/ 1 frame ( % ~ up to cr )

From Header (?) to Terminator (cr)

Max. 240 letters/ 1 frame ( ? ~ up to cr )

Hayes Co. AT Command Method, 2400bps

Item Specification

This is a leased communication unit that enables 1:1 or 1:N two way communication by using Computer and own CCU

protocol, as well as executing computer link function and data transmission function.

Computer Communication Unit (CCU)

Page 49: Oemax Nx Plc

OEMaxNX Series I 49

■Wiring Diagram

■Computer Link Function

(Without FLOW Control Method)

�Wiring Diagram is different from those of the existing N70, N700 Series. �Special caution is required because “SG”of Communication port is No. 5.

CCU (9P) Computer (9P)

Caution

�Operating sequence of Computer Link Function is computer

sends COMMAND to PLC(CCU) and PLC returns RESPONSE

according to the format of SECTOCOLCOM, which is a own

protocol. In accordance with this sequence(PROTOCOL),

through the intermediation of CCU Module, the computer can

execute communication with PLC so as to be able to obtain or

provide each kind of PLC information.

�With 1:N Function of CCU, this unit can display enormous power

because that computer link function against any PLC, that is

interfaced with LINK LOOP(including LINK LOOP1/LINK LOOP2)

with the computer linked with CCU when PLC is configured in

Network, can be used.

�Software is required only at the side of the Computer in order to

use the Computer Link Function. (MMI S/W : C-language,

BASIC....) but, PLC(CCU) itself does not require any programs.

�The Command that can be transmitted at one time and the

response data that can be received at one time is up to 118

BYTE.

■Example of Configuration

1:1 Communication 1:N Communication (When MW-Link Module is used)

Command%01#RDD..

Response%01$RD...

※ Specify LINK No. ofTransmitter Whenconfiguring MW-LINK (01~32)

NX70 Series

NX700 Series NX700 Series

Twist Pair Cable

CCU Unit

�N0.6 PLC Data WRITECOMMAND Transmission(%06#WCCD....) RESPONSE Receipt(%06$WCC....)

�PLC Data READ COMMANDTransmission (%01#RDD...)

RESPONSE Receipt (%01$RD..)

Pin No Mnemonic1

2

3

4

5

6

7

8

9

FG

SD

RD

SG

RTS

CTS

ER

Pin No Mnemonic1

2

3

4

5

6

7

8

9

CD(DCD)

RD

SD

DTR

SG

DSR

RTS

CTS

RI

�BASIC�C Language

�BASIC�C Language

Page 50: Oemax Nx Plc

50 I OEMax NX Series

This is a NX-Plus CPU leased Communication unit that enables 1:1 or 1:N Multi-drop communication by using

Computer and own CCU+ protocol, as well as enabling data transmission/receipt up to 250 bite at one time

CCU+ Module can not be used with αseries.Caution

■Characteristics

1. Communication between PLC and Computer can be realized

easily and economically

1:1 or 1:N interface can be achieved with RS232C/485 port without

specific interface and regardless of type. READ/ WRITE information

of data can be collected without complex system configuration.

2. Communication between PLC ↔ Computer to be N plus

Protocol as it is

When CCU+Unit is short of 2 EA of Communication Port provided

by CPU, mount on I/O slot and can be used according to the

format of N-plus(NX-CPU700p, NX70-CPU70p1/2) Protocol.

3. Communication between PLC↔Touch Panel, MMI Device

Can communicate with PLC with N-plus (N70 plus, N700plus,

NX-CPU700p) protocol embedded in most of MMI Software and

Touch Panel, etc.

∙MMI S/W∙Programming S/W

Touch Panel etc.

RS232C/ RS485 Cable

CCU+ Module

Computer

■Performance Specification

Interface

Transmission Speed

Communication Method

Synchronous Method

Transmission Distance

Transmission Code

Transmission Data Format

Data Transmission Seq.

Transmission Unit

Max. Length of Message

Interface with CPU Unit

I/O Allotment

Error Check Method

RS232C/ RS485, 1 port

4800/ 9600/ 19200/ 38400bps (Select according to DSW1, DSW2)

Half-Duplex Method

Polling Method

When RS232C is used: Max.15m When RS485 is used: Max. 1.2Km

HEX(Binary)

STOP bit: 1bit

Parity: No Parity

Length of Data: 8bit

By word byte unit transmit from lower byte unit

From DA(Destination Address) to CRC-16 code Byte unit

Up to MAX. 250 Byte

Internal BUS Interface

Not allotted

CRC-16 method

Item Specification (NX-CCU+) (NX70-CCU+)

Computer Communication Unit(CCU+)

NX700 CCU Unit(NX-CCU+)

NX70 CCU Unit(NX70-CCU+)

Page 51: Oemax Nx Plc

OEMaxNX Series I 51

■Wiring Diagram

■Computer Link Function

■Example of Configuration

(Without FLOW Control Method)

�Operating sequence of Computer Link Function is computer

sends COMMAND to PLC(CCU+) and PLC returns RESPONSE

according to the protocol format of NX70-CPU, NX-CPU700p,

which is a own protocol. In accordance with this sequence

(PROTOCOL), through the intermediation of CCU Module, the

computer can execute communication with PLC so as to be able

to obtain or provide each kind of PLC information.

�Software is required only at the side of the Computer in order to

use the Computer Link Function.

(MMI S/W : C-language, BASIC / Programming S/W, etc.)

but, PLC(CCU) itself does not require any programs. .

�The Data that can be transmitted at one time is up to 250 BYTE.

The following picture is an example of configuration for N-Plus Series.

PLC(CCU+), 9Pin Male Computer (9Pin Female)

1:1 Communication 1:N Communication

CommandFF002303..

Response00FFA30A..

RS232C

�PLC Data READ COMMANDTransmission (FF002303...) RESPONSE Receipt (OOFFA30A..)

NX-CPU700P CCU+ Module

RS485

RS485

Computer(RS485/RS422)

T/P(RS485)

CCU+ Module

Pin No MnemonicFG

TXD

RXD

RTS

GND

485-

485+

CTS

Vcc

1

2

3

4

5

6

7

8

9

Pin No Mnemonic1

2

3

4

5

6

7

8

9

FG

RXD

TXD

DTR

GND

DSR

RTS

CTS

-

�BASIC�C언어

Page 52: Oemax Nx Plc

52 I OEMax NX Series

■Performance Specification

Interface

Transmission Speed

Communication Method

Activation Method

Transmission Distance

Transmission Code

Transmission Data Format

Data Transmission Seq.

Transmission Unit

Max. Length of Message

I/O Allotment

End Point(終端) Code Setup

Start Point(始端) Code

Interface with CPU Unit

Other Special Control

RS232C/ RS485, 2 port

To be selected according to DSW1, DSW2

1) When RS232C is used: 300/ 600/ 1200/ 4800/ 9600/ 19200/ 38400bps

2) When RS485 is used: 4800/ 9600/ 19200/ 38400bps

Half-Duplex Method

Supplementary Activation Method( START - STOP method)

When RS232C is used : 15m(MAX), When RS485 is used: 1.2Km (MAX)

ASCII or HEX(Binary)

STOP Bit 1bit / 2bit

Parity or not (even/odd)

Length of Data 7bit / 8bit

Transmit from Bit 0 by Character Unit

Message Unit up to end point code(variable length)

MAX. 500 Byte/ Frame (end point, start point code inclusive)

Shared Memory Method �In case of NX-Series: READ, WRITE can be done with Application Command F150(READ), F151(WRT)

�In case of NXplus Series: READ, WRITE can be done with READ,WRITE

I/P 16 p, O/P 16 P allotted

Either select from ①cr ②cr+LF ③ETX or setup random code from shared memory

Start Point Code /or not

End Point Code Cut Transmission/Receipt Mode(control according to sequence command), convenient for printer O/P.

Soft reset (Control according to sequence command)

Item Specification

■Characteristics

1. 2 Channels (RS232C, RS485 Optional) are mounted in the Unit.

2. Data I/O can be executed with simple Sequence Command only.

Reading Data from SCU can be executed with PLC Application

Command[READ] and writing down data into SCU can be

executed with Application Command[WRT]. Because that CPU

UNIT and shared memory of SCU will execute after-measures,

there is no need to prepare complex.

3. As for SCU unit, use was extended by adding RS-485 Network

Function on the previously used Function of N-Series SDU.

4. Enabled Network-building by using RS232C communication

and RS485 communication

�Enabled Data I/O with RS232 device: Data I/P can be done by

interface with IDX displayer, measuring instrument, barcode reader

and printer, etc

�Enabled Data I/O by network with RS485 device: Interface with

Temperature Controller, Network Inverter, Network Servo and Network.

5. Can be mounted on PLC slot without limit. Transmission can be

made 500 Byte at one time.

6. ASCII or HEX(Binary) can be used as means of usable

Transmission Code

Data I/O can be done with devices communicating RS485 and RS232C such as Bar Code Reader (RS232C), Network

Inverter(RS485), etc. ASC11 and HEX(Binary) communication can be done with Ladder Program. (SCU Module =

existing SDU Module Function+485 Communication Function)

NX70 SCU Unit(NX70-SCU)

NX700 SCU Unit(NX-SCU)

Read Data with Appl. Command(READ) Network Servo Drive

Barcode Reader

Network Inverter

Temperature ControlleWrite down Data with Appl. Command(WRT) Temperature Controll

Serial Communication Unit(SCU)

Page 53: Oemax Nx Plc

OEMaxNX Series I 53

■Wiring Diagram

■Communication Protocol Send/Receive Function

■Example of Configuration

(Without FLOW Control Method)

�Have function to transmit after setting up communication

protocol with ladder program through SCU module and analyze

received protocol to process data. However, own communication

protocol like CPU is not embedded.

�1:1 system configuration can be made through RS232C terminal

block of SCU and also, 1:N interface through RS485

communication terminal block can be done. Communication

Master or Slave Function through each port is also available.

SCU (9Pin Female) RS-232C equipment

& Ex. of Wiring

<RS485 Ex. Of Wiring>

485-T/B

485+T/B

485-T/B

485+T/B

1:1 Communication 1:N Communication

SCU Module

LeasedController

Temp. Controller

Inverter

Inverter NetworkServo Drive

PLC

SCU Module

Bar Code Reader

Pin No Mnemonic1

2

3

4

5

6

7

8

9

FG

SD

RD

-

SG

485-

485+

CTS

Vcc

Mnemonic

RD

SD

DTR

SG

DSR

RTS

CTS

-

Page 54: Oemax Nx Plc

54 I OEMax NX Series

�NX700 : NX-CPU750A/ B/ C/ D, 700P Unit �NX70 : Can be used with NX70-CPU750, CPU70P2 Units only

�NX700 PLC does not have W-Link Unit■Wire Link Function (W-Mode)

NX700 PLC MWLINK Unit

(NX-MWLINK)

NX70 PLCMWLINK Unit

(NX70-MWLINK)

■Characteristics 1. PLC Network can be configured by interfacing up to

maximum 32 EA with W-Link Unit of N70, N700, NX70,

NX700 Series and “W-Mode”of MW-Link Unit. .

2. Network that can be easily connected with Twist Pair Cable

Interfacing uses economical TWISTED-PAIR Cable so as to

configure excellent COST Performance PLC NETWORK.

3. Computer Link Function can be used when CCU is mounted

Computer Link Function can be used with CCU Unit when PLC is

configured in Network. (or "COM" Port of CPU Module can be

used.)

4. Enabled Intensified management function by 2 hierarchy

(layers) of W-LINK Unit.

Up to 3 EA can be mounted at CPU Unit including MW-Link and

CCU. If configured 2 layers with 2 EA of MW-Link mounted,

intensified management of PLC Interfaces in the layers or data

information can be achieved. .

5. TOKEN-BUS Method, Total Extension 800m

Since Network type is BUS method, there is no need of wiring in

LOOP topology and total extension of 800m can be utilized.

Multi function PLC Network Unit up to maximum 32 EA with Twist-Pair Cable. Having W-Mode with generalized W-Link

Function and W2-Mode with large capacity data transmission and data transmission for PLC Link, diverse network solution can

be provided with one kind of module. 2 layer network enabled (PLC Link, Computer Link, Data Transmission, Remote

Programming function).

■Performance Specification

Comm. Method

Trans. Method

No. of Interface Stations

Trans. Cable

Trans. Distance

Trans. Speed

Function/

No. of Stations

(局數)

Capacity of PLC Link

(per 1 Unit)

Interface

RAS Function

Token Bus Method

BASE-BAND Method

32 Stations/ Layer, 2 Layer

Twist Pair Cable(2 line type)

800m (Total Extension )

0.5Mbps

①PLC Link Function(Max.16 Stations)

②Computer Link Function (Max.32 Stations)

-> CCU Unit required

③Data Trans.Function(Max.32 Stations)

④Remote Programming Function(Max. 32 Stations)

⑤Layer Link

Link Relay(L) : 1,024 P x 2 *1

Link Register (Ld) : 128word x 2

RS485 Multi-drop

Hardware self diagnosis function

Item Specification

Twist Pair Cable Twist Pair Cable

MW-Link Module(W-Mode)NX700 Series NX700 Series

NX70 SeriesMW-Link Module(W-Mode)

MW-Link Module

Max. 32 EA Interface

Multi Wire-Link Unit

Page 55: Oemax Nx Plc

OEMaxNX Series I 55

①Mutual control between each PLC or Data sharing can de done

by cyclic transmission of information. With this, interfaces of

other PLC in network and data information can be shared and

this function is indispensable for consecutive and coherent

progress of work and in the field of PLC network.

②This information exchange is executed by Link Relay(L) and Link

Register(Ld) in each PLC.

�Link Relay (L) : 1024 P/ Layer

�Link Register (Ld) : 128 words/ Layer

③Up to 2 layer can be configured by mounting 2 EA of MW-Link

Unit on 1 EA of CPU Unit.

④This Function is available up to 16 EA per Layer.

■Wire Link Function (W-Mode)

�PLC Link Function

①This Function is to monitor or READ/WRITE interfaces of each

PLC or data information configured on PLC NETWORK when

mounted CCU Unit is interfaced with Computer on PLC

NETWORK interfaced with MW-Link Unit.

②This Function requires a separate CCU Unit and executes

program in C-Language or BASIC Language, utilizing

SECTOCOL which is a leased protocol of CCU.

③This Function is available up to 32 EA per each Layer. .

�Computer Link Function ①Programming can be done with whatever PLC on PLC

NETWORK interfaced with MW-Link Unit. Accordingly, edit of

program (correct, delete, add) or READ/ WRITE of data to other

PLC through programming device (WinFPST S/W) can be

executed.

② In particular, this function is very convenient in operating PLC on

the Network without moving programming device.

③This Function is available up to 32 EA per each Layer.

�Remote Programming Function

This Function is to collectively send/receive each kind of interfaces

between PLCs or data information in large quantity on PLC

NETWORK which is interfaced with MW-Link. Additionally, this

function controls data send/receive with Ladder Command (F145,

F146), which is a User Program of PLC. This Function is available

up to 32 EA per each Layer.

�Data Transmission Function

Below picture is an example of NX-CPU750 program.

Data Transmission

PLC Link

XO

ROF0(MV)

WX1

Ld1

RO

RO F0(MV)

Ld1

WY1

( ) ( )LO LO Y30

F145(SEND)

DT 0

DT 100

FL 0

K 0

ROF146(RECV)

WR 0

DT 0

K 0

WY 6

Interface with up toMax. 32 EA

Interface with CCU

WinFPSTS/W

No. 5 PLC No. 6PLC No. 7 PLC No. 9 PLC

RemoteProgramming

Ladder ProgramFor NO.9 PLC

Computer Link

Data READ of NO.5 PLCCOMMAND Trans(%05#RDD.....)RESPONSE Rec.(%05$WRDD...)

C-LanguageBASIC

Page 56: Oemax Nx Plc

56 I OEMax NX Series

■Characteristics

1. PLC Network up to Maximum 32 EA can be configured with

MW-LINK Unit of NX70, NX700 PLC.

2. Large Capacity Data Transmission enabled (1,020 words/ 1

Command)

The capacity of Data to be transmitted by Data Transmission

COMMAND [F145(SEND)] [F146(RECV)]is drastically extended

up to 1,020 words per 1 Command so as to improve

inconvenient problems in the existing W-Link Function.

(Capacity of transmission with the existing W-LINK was up to 16

words per 1 command)

3. Drastic Improvement in PLC Link Function (PLC Link 32 Stations,

Extension of Link Capacity)

Up to 32 EA can be set up when PLC Link Function is used and

in particular, PLC Link capacity is drastically extended. (L: 4,096

points, Ld: 4,096 words) Link Relay (L) and Link Register (Ld)

Area can be set up with Ladder Program and WinFPST 2.24 S/W.

4. Computer Link Function can be used when CCU is mounted

Computer Link Function can be used with CCU Unit when PLC

Network is configured. (or "COM"Port of CPU Module can be

used as well.)

5. Transmission Cable can be easily connected with Twisted-

Pair Cable..

6. Transmission Distance can be extended. (up to 1,200m)

Interface and communicate up to 1,200m according to change

of Transmission Speed. (In case of 250Kbps, up to 1,200m)

7. Enabled Intensified management function by 2 hierarchy

(layers) of MW-LINK .

Up to 3 EA can be mounted on CPU Unit including MW-Link

and CCU. If configured 2 layers with 2 EA of MW-Link mounted,

intensified management of PLC Interfaces in the layers or data

information can be achieved. (Up to 8 EA for NX-CPU750C and

NX-CPU750D Unit)

■Wire Link Function (W2-Mode)

■Configuration Diagram �NX700: NX-CPU750A/ B/ C/ D Unit

�NX70: NX70-CPU750 Unit

MW-Link Unit W2 Mode can be used with

■Performance Specification

Communication Method

Transmission Method

No. of Interface Stations

Transmission Cable

Transmission Speed

Function/No. of Stations

PLC Link Capacity

(per 1 Unit)

Interface

RAS Function

Token-Bus Method

BASE-BAND Method

32 Station/ Layer, 2 Layer

Twist-Pair Cable (2 line type)

1200m (Total extension)

800m (Total extension)

500 Kbps / 250 Kbps

①PLC Link Function (Max. 32 stations)

②Computer Link Function (Max.32 Stations) -> CCU Unit required

③Data Trans.Function(Max.32 Stations), 1,020 words/1 Command

④Remote Programming Function(Max. 32 Stations)

⑤Layer Link(2 Layer with interface up to 2 EA of MW-Link per 1 CPU)

Link Relay(L) : 4,096 points x 2

Link Register(Ld) : 4,096 words x 2

RS485 Multi-drop

Hardware self diagnosis function

250Kbps setup

500Kbps setup

Trans.Distance

Item Specification (W2-Mode)

Twist-Pair Cable Twist-Pair Cable

MW-Link Module(W2-Mode)NX700 Series NX700 SeriesNX70 Series

MW-Link Module(W2-Mode)

MW-Link Module(W2-Mode)

Max.Interface 32 EA

Page 57: Oemax Nx Plc

OEMaxNX Series I 57

①Mutual control between each PLC or Data sharing can de done

by cyclic transmission of information. With this, interfaces of

other PLC in network and data information can be shared and

this function is indispensable for consecutive and coherent

progress of work and in the field of PLC network.

②This information exchange is executed by Link Relay(L) and Link

Register(Ld) in each PLC.

�Link Relay (L) : 4096 P/ Layer

�Link Register (Ld) : 4096 words/ Layer

③Up to 2 layer can be configured by mounting 2 EA of MW-Link

Unit on 1 EA of CPU Unit.

④This Function is available up to 32 EA per Layer.

■Wire Link Function (W2-Mode)

�PLC Link Function

①This Function is to monitor or READ/WRITE interfaces of each

PLC or data information configured on PLC NETWORK when

mounted CCU Unit is interfaced with Computer on PLC

NETWORK interfaced with MW-Link Unit.

②This Function requires a separate CCU Unit and executes

program in C-Language or BASIC Language, utilizing

SECTOCOL which is a leased protocol of CCU. With this

function, up to maximum 32 EA of PLC interfaced with MW Link

Unit can be controlled from the Computer. (“COM”Port of CPU

can be used as well))

③This Function is available up to 32 EA per each Layer

�Computer Link Function

①Programming can be done with whatever PLC on PLC

NETWORK interfaced with MW-Link Unit. Accordingly, edit of

program (correct, delete, add) or READ/ WRITE of data to other

PLC through WinFPST S/W can be executed.

② In particular, this function is very convenient in operating PLC on

the Network without moving programming device.

③This Function is available up to 32 EA per each Layer.

�Remote Programming Function

This Function is to collectively send/receive each kind of interfaces

between PLCs or data information in large quantity on PLC

NETWORK which is interfaced with MW-Link. Additionally, this

function controls data send/receive with Ladder Command (F145,

F146), which is a User Program of PLC.(1,020 words can be

transmitted with 1 Command) This Function is available up to 32 EA

per each Layer.

�Data Transmission Function

Interface with up toMax. 32 EA

Interface with CCU

WinFPSTS/W

No. 5 PLC No. 6PLC No. 7 PLC No. 9 PLC

RemoteProgramming

Ladder ProgramFor NO.9 PLC

Computer Link

Data READ of NO.5 PLCCOMMAND Trans(%05#RDD.....)RESPONSE Rec.(%05$WRDD...)

Below picture is an example of NX-CPU750B program

Data Transmission

PLC Link

XO

ROF0(MV)

WX1

Ld1

RO

ROF0(MV)

Ld1

WY1

( ) ( )LO LO YO

F145(SEND)

DT 0

DT 100

FL 0

K 0

ROF146(RECV)

WR 0

DT 100

K 0

WY 0

C-LanguageBASIC

Page 58: Oemax Nx Plc

58 I OEMax NX Series

REMOTE I/O Master Module (NX-MASTER)

REMOTE I/O Slave Module (NX-SLAVE)

REMOTE I/O Slave Module (NX70-SLAVE)

�Remote system can be used with NX-CPU750A/B/C/D, 700P Units only

Easy wiring with Twisted-Pair Cable of RS485

Up to Max. 32L.S. can beinterfaced per 1Master

I/O Information can be exchanged with 2 line wiring to Remote Control System

2 Channel Wiring per 1 Master Unit enabled so as to effectively handle the dispersed I/O Devices.

(32 Units of Slave Units per 1 Master Unit can be interfaced)

Remote I/O System

Base StationNX-MASTER

NX700 SeriesNX700 Series NX70 Series

NX70 Series NX70 Series

■Solenoid Valve that can be interfaced

SMC(Co.) CKD(Co.) 小�井Manuf.(Co.)

NX70 Series

Slave UnitSlave UnitSlave Unit

Slave Unit Slave Unit

: Slave Unit

: MASTER Unit

Slave Unit

B.Station

L.Station

L.SL.SL.S

L.S L.S L.S

Page 59: Oemax Nx Plc

OEMaxNX Series I 59

■Characteristics

1. Remote Control of I/O Information with 2 Channel Wiring

For wiring convenience, transmission line can respond to up

to 2 channels per 1 Master Unit. In addition, 1 CPU can

control I/O of maximum 8 CH because 1CPU can mount up

to 4 Master units. Designing the wiring route can be easily

executed because layout can be done freely.

2. High Speed, Long Distance Transmission

Transmission Speed of 0.5Mbps, total extension can be

transmitted up to 700m. 2 line type can be used for cable

wiring which is economical.

3. Maximum 1,024 Point I/O Control per 1 unit of Master Module

(CPU750A, CPU750B)

Maximum 4,096 Point I/O Control per 1 unit of Master

Module (CPU750C, CPU750D)

Maximum 1,024 point I/O Control can be achieved because 1

Master Unit can interface 32 EA of Local Stations (Slave

Unit). (But, CPU750C, CPU750D Module can control up to

8,192 point per 1 Unit of CPU)

■Pointer of REMOTE I/O System

�REMOTE I/O System is a system that can control dispersed I/O

with 2 line type cable.

�Up to 4 wiring routes can be selected so as to be able to respond

to the complex layout of local stations.

�This Network is recommended when you want to place I/O at this

or that place, like when you install control box at a remote location.

(Use of extended Motherboard is recommended when high speed

process is required.)

■Performance Specification

Communication Method

Activation Method

Transmission Line

Transmission Distance

Transmission Speed

No. of MASTER

No. of SLAVE

Control I/O Point

Interface

Trans. Error Check

Combined Use of Products

2 Line type Half-Duplex

Supplementary (調步) Activation Method

Twisted-Pair Cable (VCTF Cable)

Total extension 700m

0.5Mbps

4 EA/ CPU 1 EA

Max. 32 Stations (per 1 Master Unit)

�Max. 1,024 P (per 1 Master Unit)

�Max. 2,048 P (per 1 CPU Unit)

※CPU750C, D Module can control up to 8,192P

RS485 (Multi-drop ), 2Port

CRC Method

NX70, NX700 SLAVE Unit

Item Specification

■Product Configuration Summary

Mount on Basic, Extended

Motherboard to use (up to 4 units)

Mount on the existing CPU Unit

of Basic Motherboard

REMOTE I/O

MASTER Unit

REMOTE I/O

SLAVE Unit

NX-MASTER

NX-SLAVE

NX70-SLAVE

NX700

NX700

NX70

Type of Product Mounting Method PLC Product No.

Page 60: Oemax Nx Plc

60 I OEMax NX Series

■Characteristics

■Network Configuration Diagram

�Ethernet System is a leased Open Network System for CPU750 of NX700.

�This is a Communication Unit to interface NX700 PLC with Ethernet (100BASE -TX,

10BASE-T, 10BASE5), according to TCP/IP and UDP/IP.

�Maximum 8 portion of connection communication can be achieved with 1EA so as to be

able to interface with multiple opposite NODE.

�When interfaced with LAN by using Ethernet Unit of NX700, Computer Link Function, Data

Transmission Function, Remote Programming and Permeable Communication Function

can be used between other PLC on the Network(LAN) and Computer at transmission speed

of maximum 100M bit/s.

�When interfaced with LAN by using Ethernet Unit of NX700, programming at

Computer(WinFPST S/W)interfaced with LAN Network can be done so that programming

edit can be done from anywhere.(Remote Programming)

�Communication Setup can be done easily by using "Control Configurator ET" which is a

Setup software. Accordingly, Communication Setup being executed on Ladder Program

can be used easily by utilizing this software.

EtherNet Unit

EtherNet System

MW-Link Unit

MW-Link Unit

MW-Link Network(W2Mode) W-Link Network(WMode)

W-Link Unit

Ethernet Unit

Ethernet Unit

Ethernet LAN

Ethernet LAN

Ethernet LAN Ethernet LAN

WinFPST S/W

MW-Link Unit

W-Link Unit

Computer Link

Computer Link

Permeable Comm

Data Transmission

RemoteProgramming

Router

Router

Page 61: Oemax Nx Plc

OEMaxNX Series I 61

■Characteristics

■ Corresponds to TCP/IP and UDP/IP Corresponds to 2 Protocols(TCP/IP and UDP/IP) so as to be able to

communicate widely with computer and the like on Network(LAN).

■ 8 Connection Communication with 1 EA Maximum 8 portion of connection communication can be achieved

with 1 EA so as to be able to interface with multiple opposite NODE

■ Corresponds to 3 kinds of Communication Interface Corresponds to 3 kinds of Communication Interface(100BASE-TX,

10BASE-T and 10BASE5). (Only one kind of Interface can be used).

1) 100BASE-TX and 10BASE-T: Use UTP Cable (switch transfer)

2) 10BASE5: Use Transceiver Cable

■ Supports Diverse Communication Function Supports SECTOCOL Communication Function (Computer Link

and Data Transmission) that can communicate between PLC NX

Series and Permeable Communication Function that can

communicate with General Purpose Devices like Computer.

1) Computer Link Function�I/O Interface, contents of Register and contents of Program of PLC

interfaced with remote Computer or Work Station can be freely READ/Write.

�Maximum length of message for 1 frame is 2k Byte.

2) Remote Programming Function �With WinFPST S/W, which is a SAMSUNG PLC Software Tool,

programming edit(insert, delete, correct)or monitoring at PLC from

remote Computer through LAN Network can be done.

3) Data Transmission Function �Following execution of SEND/RECV Command of PLC, exchange of

I/O(Interface) and Register Information between Computer interfaced

with Ethernet Unit or Work Station and PLC can be achieved

4) General Purpose Communication by PermeableCommunication Function enabled

�Permeable Communication can be achieved between PLC interfaced

with Ethernet Unit and Computer or Work Station can be achieved.

�SEND/RECV Data Storage and Read in PLC is executed by

SEND/RECV Buffer of Shared Memory inside NX-EtherNet Module.

SEND/RECV requests and the like are executed by Bit ON/OFF at

Shared Memory Handshake Area.

■ Simple Communication Setup Communication Setup can be done easily by using "Control

Configurator ET" which is a Setup software.

�Communication Setup being executed on Ladder Program can be

easily set up by utilizing this software.

�The existing Ladder Program setup can be used by conversion of

Mode Switch. (Auto Connection Function)

■ Perfect Self Diagnosis Function Occurrence of mal-function can be easily dealt with according to

the following Self Diagnosis Function.

�Hardware under transmission and communication status check

function.

�Hardware and communication status check function followed by

Test Mode execution.

�Error log function for each type of check result can be used.

■Performance Specification

I/O Occupancy Point

Location of Mount/Restriction on number ofunits

Communication Function

32SX/ 32SY ※1

Mountable up to 3 units on the basic motherboard

(including W@-Mode of MW-Link Unit)

�When CPU750A, CPU750B are used: 3 EA

�When CPU750C, CPU750D are used: 8 EA

�Computer Link: Max. 2K Byte

�Data Transmission: Max.1020 words

�Remote Programming ※2

�Permeable Communication

Max. 3 Connection ※3

Max. 8 Connection

Setup on ex-factory: (1k word /1 Connection)×3

Setup on ex-factory: (1k word /1 Connection)×3

Item Specification

System Connection

Connection

For Transmit.

For Receive

NO. of Comm.

Connections

Buffer for Permeable

Communication ※3

※1. Setup of「0E」can be done by use of WinFRST S/W.

※2. LAN Circuit pass Interface is not supported at "Configurator ET" setup S/W.

※3. System Connection is used only with a computer interfaced with LAN circuit by using

WinFPST S/W.

※4. Send/Receive combined 6K word can be randomly assigned to 8 connections.

�Interface of Network (1) 100BASE-TX / 10BASE-T (T)

100BASE-TX

10BASE-TConnector

Not in Use.

Not in Use.

UTP Cable

(2) 100BASE5 (AUI)

10BASE5(AUI) Connector

12V DC(below1A)

RetainerCheck if pressed

downward

External Power Supply

Terminal Block

Transceiver Cable

AUI

T

12V

AUI

T

12V

■Transmission Specification

Data Trans. Speed

Trans. Method

Max. Length of Segment

Max. Distance between Nodes

Communication Cable

Transceiver Cable

Ma. NO. of Nodes

Node Interval

100M bit/s

205m

10M bit/s

Base Band

500m

100m

UTP Cable

10M bit/s

500m

2,500m

Transceiver Cable

50m

100 Node/Segment

Integer Multiple of 2.5m

Item 100BASE-TX 10BASE-T 10BASE5

SEND Command

RECV Command

WRITE with Register of the opposite Node

READ with Register of the opposite Node

Page 62: Oemax Nx Plc

62 I OEMax NX Series

NX700 PLC DeviceNet Master Unit provides Network and Master Connection configured with NX700 PLC and

DeviceNet I/O Products. ( ODVA 2.0 )

1.Have RS232C Communication Port and DeviceNetCommunication Port.

2. Multi mounting of DeviceNet Master Unit (DNM) in the samePLC can be achieved.

3. Shared Memory is retained inside of DNM Unit so as toexchange Data between PLC CPU and DeviceNet Devices byusing WRITE, READ Commands supported by NX700 PLCCommand Word Set. (Maximum I/P of 4096 point and O/P of4096 point can be controlled)

4. DNM Unit follows ODVA (Open DeviceNet Vendor Association)DeviceNet Specification 2.0.

5. Bit-Strobe, Polling, Cyclic I/O control method is provided forcontrol of DeviceNet I/O products.

6. Limited Device Configuration can be done by use of ExplicitMessages.

7. Configuration Tool is provided for communication speed and I/Oallotment.(Configuration Tool for SYCON TOOLS Windows 95/NT that canconfigure Network Information and Scan List)

8. Configuration Tool executes configuration through Serial Port onDNM Unit.

9. DNM Unit stores Configuration Information in Flash Memory.

10. DNM Unit supports automatic, consecutive Scan Function.

■Characteristics

NX700 PLC

DeviceNet Master Unit

(NX-DEVICE)

Write Data with Appl. Command(WRT)

Read Data with Appl. Command(READ)

■Performance Specification

Communication Method

DeviceNet I/O Slave messaging (Group 2 Only Slave)

I/O Exchange

�Poll Command : Y

�Bit Strobe Command : Y

�Cyclic Command : Y

�COS Command : Y

Max. 64 Nodes/ 1 Network (Including Master)

100m/ 500kbps, 250m/ 250kbps, 500m/ 125kbps

- Supports automatic setup

500kbps

500m

DeviceNet Cable

Polling , Strobe , Change-of-State , Cyclic

Automatic Setup Max. 500Kbps

Rated Voltage: 24V DC Nominal

Voltage Range: 11V ~ 28.8V DC

Power Consumption : 1.5W Max.

ODVA Conformance Test Authentication under way

Item Specification

NO. of Interface Node

Distance/Trans. Speed

Max. Data Trans.Speed

Transmission Line

Communication Method

Comm. Speed Setup Method

DeviceNet Power

Approval

DeviceNet Master Unit

Guaranteed Transmission Distance

Page 63: Oemax Nx Plc

OEMaxNX Series I 63

DeviceNet is trademark of ODVA.

NX700 PLC

NX-DEVICE

Devicenet(Slave)

Devicenet(Slave)

DeviceNet(Master) Computer

Computer

NCS-DN(S/W)(Contiguration)

DeviceNet(Slave)

Devicenet(Slave)

DeviceNet

DeviceNet

NCS-DN(S/W)(Configuration Tool)

TerminatingResistance

TerminatingResistance

NetworkPower(24)

■DeviceNet Communication Configuration

■Wiring Method

(1) RS232C Comm. Connector

Interface with Computer (Configuration Tool)

(1) DeviceNet Comm. Connector

Interface with DeviceNet Network

1

2

3

4

5

6-9

N.C

TxD

RxD

N.C

GND

N.C

Type D-Sub, 9Pin Female

Pin

1

2

3

4

5

V -

CAN_L

Shield

CAN_H

V +

TypeDeviceNet, 5Pin

Male

PinDeviceNet Comm.Connector, 5 pinFemale

Page 64: Oemax Nx Plc

64 I OEMax NX Series

Page 65: Oemax Nx Plc

NX

7 Series

마크취득제품

NX7 Basic Model (10/14/28 Points)(NX7S-10ADR, NX7S-10ADT)

(NX7S-14ADR, NX7S-14ADT)

(NX7-28ADR, NX7-28ADT)

(NX7-28DDR, NX7-28DDT)

NX7 Extended Model (14/28 Points)(NX7-14EDR, NX7-14EDT)

(NX7-28EDR, NX7-28EDT)

NX7 Basic Model (48 Points)(NX7-48ADR)

(NX7-48ADT)

(NX7-48DDR)

(NX7-48DDT)

■Peripheral Devices

■NX7 PLC

User Software

OEMaxNX Series I 65

Page 66: Oemax Nx Plc

66 I OEMax NX Series

NX7 Series is a single packaged miniature PLC suitable for controlling the small sized machinery unit with basic 28

points and 48 points in compact size available, which can be extended up to 104 points. HSC, Pulse O/P and PID

Process Function, 2 Communication Ports (RS232/485) are included. All Command words(excluding Data Link) of

SPC10 and N-plus Series support Programming (Software and Command Words) and the existing Programs can be

Downloaded as it is.

■Product Configuration

NX7 Basic Model (10/14/28Points)(NX7S-10ADR, NX7S-10ADT)(NX7S-14ADR, NX7S-14ADT)(NX7-28ADR, NX7-28ADT)(NX7-28DDR, NX7-28DDT)

NX7 Extended Model(14/28Points)(NX7-14EDR, NX7-14EDT)(NX7-28EDR, NX7-28EDT)

NX7 Basic Model (48Points)(NX7-48ADR)(NX7-48ADT)(NX7-48DDR)(NX7-48DDT)

[Peripheral Device]

User Software

■Product Model Configuration

Series (NX7=확장가능,

NX7S=확장불가)

I/O PointPwr Spec. or Classification of Extension

(A=AC Pwr I/P, D=DC24V Pwr, E=Extension Module)

I/P Mode(D=DC I/P)

O/P Mode(R=Relay, T=Transistor)

NX7-□□□□□-□A6=Analog 6p(4In/2Out)

4=Analog 4p(4In)

■Configuration Diagram

WinGPC

RS232C

■Kinds of Product Model

Basic Model

(28 Points)

Basic Model

(10 Points)

Basic Model

(14 Points)

Basic Model

(48 Points)

Extended

Model

Analog

NX7S-10ADR

NX7S-10ADT

NX7S-14ADR

NX7S-14ADT

NX7-28ADR

NX7-28ADT

NX7-28DDR

NX7-28DDT

NX7-48ADR

NX7-48ADT

NX7-48DDR

NX7-48DDT

10p(DC IN 6p, Relay Out 4p)

10p(DC IN 6p, Tr Out 4p)

14p(DC IN 8p, Relay Out 6p)

14p(DC IN 8p, Tr Out 6p)

28p(DCIN 16p, Relay Out 12p)

28p(DCIN 16p, TR Out 12p)

28p(DCIN 16p, Relay Out 12p)

28p(DCIN 16p, TR Out 12p)

48p(DCIN 28p, Relay Out 20p)

48p(DCIN 28p, TR Out 20p)

48p(DCIN 28p, Relay Out 20p)

48p(DCIN 28p, TR Out 20p)

24p(DCIN 12p, Relay Out 8p) Analog 4p(4 In)

24p(DCIN 12p, Relay Out 8p) Analog 4p(4 In)

26p(DCIN 12p, Relay Out 8p) Analog 6p(4IN / 2Out)

26p(DCIN 12p, TR Out 8p) Analog 6p(4IN / 2Out)

AC110/220V

Free Voltage

AC110/220V

Free Voltage

AC110�220V

Free Voltage

DC 24V Power

Supply

AC110�220V

Free Voltage

DC 24V Power

Supply

AC110�220V

Free Voltage

AC110�220V

Free Voltage

Name of Unit Product Code Product Spec. I/P Power Spec.

NX7 Series

NX7-20ADR-4A

NX7-20ADT-4A

NX7-20ADR-6A

NX7-20ADT-6A

NX7-14EDR

NX7-14EDT

NX7-28EDR

NX7-28EDT

14p (DC In 8p, Relay Out 6p)

14p (DC In 8p,Tr 6p)

28p(DCIN 16p, Relay Out 12p)

28p(DCIN 16p, TR Out 12p)

Page 67: Oemax Nx Plc

OEMaxNX Series I 67

■Function and Characteristics of the Product

8. Excellent Extendibility

76Points

56Points

104Points

(Minimum 28 points ~ up to Maximum 104 points available)

■Basic I/O Configuration Diagram

�The below is an example of System Configuration using Basic and Extended Module.

9. Diverse Application to Industrial Sites

Best suited for small-sized control installations. System building

with extendibility and flexibility applicable to I/O Dispersion

System is available.

10. Clock unction Embedded

With miniature sized clock function embedded, diverse daily

scheduling management program is available.

11. Powerful Communication Network

Diverse System Configuration is available with the basically

embedded each 2 Ports of RS232C and RS485. User Defined

Communication Designation is available so as to control Inverter

and Bar Code, etc., by interfacing. User convenience was

extended with automatic Communication Speed Control up to

4800~38400bps.

1. Compatibility Secured

All Command Words of SPC10 and N-plus Series are supported

and the existing Programs can be downloaded.

2. High Speed Counter Function

Economical Control System can be built with the basically

embedded HSC 2 CH/24 BIT.

3. Pulse O/P Function

Simple Positioning and Stepping Motor can be operated with

the Pulse I/P Function of TR O/P Products.

4. Pulse I/P Catch

Normal Process can be executed by catching the signal with

short I/P Pulse up to Max. 4 Points.

5. PID Control Function Embedded

8Loop Control is available with the embedded 8 Loops PID Function.

6. Compact Size

With miniature size, Basic 28 Points, 48 Points Control is

available and 56,76, 84,104 Points configuration is available with

the Extended Configuration.

7. Convenient Use

Support Users with easy and accustomed Command Words.

I/P 60 p (R0.0~R3.3)O/P 44 p (R16.0~R18.3)

(R8.0~R9.7)(R24.0~R25.3)

(R12.0~R13.7)(R28.0~R29.3)

I/P 44 p (R0.0~R3.3) (R8.0~R9.7)O/P 32 p (R16.0~R18.3) (R24.0~R25.3)

I/P 16 p (R0.0~R1.7)O/P 12 p (R16.0~R17.3)

I/P 32 p (R0.0~R1.7) (R8.0~R9.7)O/P 24 p (R16.0~R17.3) (R24.0~R25.3)

I/P 28 p (R0.0~R3.3)O/P 20 p (R16.0~R18.3)

Page 68: Oemax Nx Plc

68 I OEMax NX Series

■ Performance Specification

Control Method

External I/O

Memory Back-Up

Special Function

Others

Program Storage, Repetitive Operation Method

Basic 28 p(I/P 16/ O/P 12 p), Basic 48 p(I/P 28/ O/P 20 p),

Extension 28 p up to 2 EA(56p) extendable, (ext. 28p: In 16p /Out 12p)

28 kinds

Approx. 150 kinds

Tens of μs/step

A few ~ tens of μs/step

9K Word

R000.00 ~ R31.15 (512p, 32word) (R32 ~ R127: Setup Range when Special Function is used)

L000.00 ~ L063.15 (1024p, 64word)

M000.00 ~ M127.15 (2048p, 128word)

K000.00 ~ K127.15 (2048p, 128word)

F000.00 ~ F015.15 (256p, 16word)

256CH (Timer+Counter, Preset Value: 0 ~65535

Timer : 0.01sec: TC000 ~ TC063 (64CH), 0.1sec.: TC064 ~ TC255 (192CH)

Counter : TC000 ~ TC255 (256CH)

W0000 ~ W2047 (2048word)

W2560(=SR000)~W3071(=SR511) (512word)

Port 1: RS232C/ RS485 Combined Use(D-SUB 9pin), 4800~38400bps Auto select

Port 2: RS232C/ RS485 Combined Use(8Pin MJ T/B), 4800~38400bps Auto Select

User PROGRAM Back-up(FlashROM) Function Basically Embedded,

HSC I CH Embedded(Single Phase 8KHz, 2-Phase 4KHz) Pulse O/P 2 CH Embedded,

Pulse Catch unction Embedded(4 Contacts)

User Definition Comm., Clock Function, PID Function

Basic Command

Application Command

Basic Command

Application Command

I/O(R)

Link Interface (L)

Internal Interface (M)

停電維持(Keep-alive During Blackout (K)

Special Interface(F)

Timer/ Counter

Data Word (W)

Special Word (W, SR)

Port 1

Port 2

CommandWord

ProcessSpeed

CommunicationFunction

MemoryCapacity

Program Capacity

Item Specification

■General Specification

Power Voltage

Impact Resistance

Earth

Other Conditions for Use

Structure

停電維持(keep-alive during Blackout)

Allowable InstantaneousInterruption

Surrounding Operational Temp.

Surrounding Operational Humidity

Surrounding Area Humidity

Vibration Resistance

Noise Resistance

Insulation Resistance

Withstand Voltage

Surrounding Storing Temp.

AC110V, AC220V (50/60Hz) Free Voltage

Below 20ms

0~55℃

-10 ~ 75℃

30 ~ 85%, (without condensing)

30 ~ 85%, (without condensing)

Frequency 16.7Hz, Amplitude 3mm. X.Y.Z. 2

Hours to each directions

10G, X, Y, Z 2 times to each directions

Noise Voltage 1500Vp-p, Noise Pulse Width 100ns,

1μs. Test Method follows Company Regulation.

AC External T/B-Case Earth(FG)between T/Bs

above 20MΩTest Method follows DC 500V Mega

AC External T/B -Case Earth(FG) between T/Bs

AC 1500V for 1 Min.

More than 3 kinds of Earth

Corrosive gases and thick dust prohibited

Open-Wall Installation Type

10일25℃(KEEP Relay Preservation)

Item Specification

■Power Supply Specification (AC I/P Type PLC)

ACPowerSupply

Rated Voltage/ Current

Allowable Voltage Range

Frequency

Power Consumption

O/P Current Capacity

AC110V~220V, Free Voltage / 0.4A max

AC85~132V, AC170~264V

47 ~ 63Hz,

Max 33 Watts

For Internal Use: 5V, 2.0A

For External Use(for Service): 24V, 0.4A

Item Specification

(DC I/P Type PLC)

Rated Voltage/ Current

Allowable Voltage Range

O/P Current

DC24V / 1.6A max

DC21.6~26.4V

For Internal Use: 5V 2.0A

Item Specification

DC PowerSupply

Page 69: Oemax Nx Plc

OEMaxNX Series I 69

■I/P Specification

I/P Spec.

Rated Voltage

Operating Volt. Range

Max. I/P Current

Min. ON Vol./Current

Max. OFF Vol./Current

I/P Impedance

Polarity

COMMON Method

OFF→ON

ON→OFF

ResponseTime

Internal CurrentConsumption (5V)

DC Voltage (all types)

DC12 ~ 24V I/P

10.8 ~ 26.4V

Below 10mA

Above 10.0V / above 3.0mA

Below 5.0V / Below 0.6mA

Approx. 3.6KΩ

Below 2ms

Below 2ms

Below 50mA

No Polarity

8p/ 1COM, 16p/ 1COM

Item DC I/P

within 2A

Internal Circuit (Relay O/P)

Internal Circuit (TR O/P)

Internal Circuit (DC I/P)

Load

Load

Ext. Supply

Int. PWR

Int.

or

기본사양

■O/P Specification

Product Code

O/P Point

Rated Loaded Vol.

Operating Loaded Vol.Range

Polarity

Max. Load Current

Internal Current Consumption (5V)

COMMON Method

OFF→ON

ON→OFF

ResponseTime

12 ~ 24V DC

10 ~ 30V DC

Common (Sink Type, NPN)

0.4A / point, 1A /Common

Below 1ms

Below 1ms

Below 80mA

1, 4, 6p/1COM

250V AC, 30V DC

85 V ~ 264V AC

No Polarity

2A / point, 6A /COM

Below 10ms

Below 10ms

1, 4, 6p/1COM

NX7-28ADT

NX7-28DDT

12 p

NX7-48ADT

NX7-48DDT

20 p

NX7-28ADR

NX7-28DDR

12 p

NX7-48ADR

NX7-48DDR

20 p

Item TR O/P RY O/P

Page 70: Oemax Nx Plc

70 I OEMax NX Series

Software that supports Programming from Computer. Mounted Diverse Functions like Ladder Edit, Monitor, De-Bugging, File

Management, Time Chart Monitoring, etc. Corresponds to all types of NX, N-Series. (excluding N-plus Series)

■Characteristics

■Configuration Diagram

1. Diverse Functions are mounted from preparation of program,

de-bugging, adjustment and up to various monitorings.

2. Selection of each function can be done by easy to understand

HANGEUL Menu Method (WinFPST) in simple operation. In

addition, not only file management function but also printed out

LIST can be used as a program specification directly.

3. Setup of PLC Environment and I/O allotment can be set up in

simple manner

4. There are 3 types of Command Word I/P methods: Mnemonic

Method, Ladder Method and Ladder Symbol Method. Uses can

freely select one from these three.

5. Edit, Interface, Forced ON/OFF Function, Interface Search

Function from ON-LINE RUNMode.

6. Functions such as Data Monitoring, Time Chart Monitoring, Error

Occurrence Monitoring, File Management.

WinFPST S/W (for Windows

MAIN Menu Multi Program Screen Program Preparation Screen (Ladder Edit)

Forced I/O Screen Status Display Screen Print Management Screen

NX70-CPU70, NX70-CPU750

NX-CPU750A, NX-CPU750B,

NX-CPU750C, NX-CPU750D

NX-CPU700

CPL02343C, CPL02543C..........

CPL9211A

CPL7211A, CPL6215A, CPL6210A,.....

PLC Series Corresponding CPU Type

NX70

NX700

N7

N70

N70

Peripheral DeviceWinFPST Software (for N Series)

WinFPST S/W Product:

Rockwell Automation Korea

Product:

Rockwell Automation Korea

Page 71: Oemax Nx Plc

OEMaxNX Series I 71

Software for Windows that supports Programming from Computer. Mounted Diverse Functions like Ladder Edit,

Monitor, De-Bugging, File Management, Time Chart Monitoring, etc. User Ladder Software corresponding to Plus

models (N70plus, N700plus, NX700(CPU700p), NX70(CPU70p), NX7, SPC-10 PLC Series).

■Characteristics

■Configuration Diagram

1. Convenient Functions of Windows can be utilized by application

of WINDOWS Environment .

2. Programming can be done while executing mutual comparison

or printing because several programs can be edited

simultaneously.

3. Programming is very convenient because diverse TOOLs for

programming are provided.

4. Diverse types of monitoring such as Ladder, Mnemonic, Time

Chart, Register Monitoring are available.

5. Ladder and Mnemonic programs are conversed automatically.

6. On-line interfaced PLC can be automatically discerned.

7. Program correction and change can be done conveniently on

on-line.

WinGPC S/W (for Windows)

Ladder Monitoring Screen Mnemonic Edit Screen Projector Management Screen

Register Monitoring Screen Time Chart Monitoring Screen Status Monitoring Screen

NX7-28ADR, NX7-48ADR........

NX70-CPU70p1, NX70-CPU70p2

NX-CPU700p

SPC-10ADR, SPC-10ADT....

CPL9215A, CPL9216A

CPL7215A

PLC Series Corresponding CPU Model

NX7

NX70

NX700

SPC

N70Plus

N700Plus

WinGPC Software (for N-plus Series)

WinGPC

Product:

Rockwell Automation Korea

Product:

Rockwell Automation Korea

Page 72: Oemax Nx Plc

72 I OEMax NX Series

Computer

D-SUB(9pin)

�D-SUB (9pin)

�NX70-CCU Com.Port(9pin)

�NX-CCU Com.Port(9pin)

�CPU Unit COM Port(9pin)

�NX70-CCU (9pin)

�NX-CCU (9pin)

�CPU Unit COM PORT (9pin)

CPU Unit TOOL PORT, 9pin

CPU Unit TOOLPORT,9pin

17JE-23090-02(D1),DDK (Male) 17JE-13090-02(D1),DDK(Female)

WinFPST(Comptr Side),9pin

WinFPST(Comtr Side),9pin

NX70-CPU70, NX70-CPU750

NX-CPU750A, NX-CPU750B,

NX-CPU750C, NX-CPU75

NX-CPU700

PLC Series Corres. CPU Model

NX70

NX700

NX70-CPU750

NX-CPU750A, NX-CPU750B,

NX-CPU750C, NX-CPU750D

PLC Series Corres. CPU Model

NX70

NX700

2

3

4

5

6

7

8

TXD

RXD

-

S.G

-

-

-

Signal PIN No.

RXD

TXD

DTR

S.G

DSR

RTS

CTS

2

3

4

5

6

7

8

PIN No. Signal

1

2

3

4

5

6

7

8

9

F.G

TXD

RXD

-

SG

-

RTS

CTS

ER

PIN No. Signal

1

2

3

4

5

6

7

8

9

CD(DCD)

RXD

TXD

DTR

SG

DSR

RTS

CTS

-

PIN No. Signal

■Corresponding CPU Module

■Corresponding CPU Module

Communication Cable

Cable for TOOL PORT of NX70, NX700 CPU

Cab le for COM PORT of NX70, NX700 CPU Unit and for CCU Unit of NX Series

17JE-23090-02(D1),DDK (Male) 17JE-13090-02(D1),DDK(Female)

TOOL PORT of CPU Module for NX70, NX700 CPU of the bove diagram can use CPL5530, CPL5531 cable.Ref

COM PORT of CPU Module of NX70, NX700 in the above diagram have same Communication specification

ith NX Series CCU Module

Ref

NX-CBLCPU02

NX-CBLCPU05

Computer

Computer

T/P(Touch Panel)

Cable for CPU of NX70 PLC, NX700 PLC

C-LanguageVisual BasicMMI S/W

Page 73: Oemax Nx Plc

OEMaxNX Series I 73

■Corresponding CPU Module

NX7-28ADR, NX7-48ADR........

SPC-28ADR, SPC-28ADT....

CPL9215A, CPL9216A

CPL7215A

CPU all

PLC Series Corresponding CPU Model

NX7

NX70

NX700

SPC10

N70plus

N700plus

2

3

4

5

6

7

8

9

Computer & PGM500 side, 9 pin

Computer and PGM500 side, 9pin

The below picture is for NX-CPU700p.

CPU Unit side, 9 pin

2m/ 5m

CPU Unit side,9p

TXD

RXD

-

S.G

485(-)

485(+)

-

Vcc

PIN No.Signal

2

3

4

5

6

7

8

9

RXD

TXD

DTR

S.G

DSR

RTS

CTS

PIN No. Signal

17JE-23090-02(D1),DDK (Male) 17JE-13090-02(D1),DDK(Female)

Cable Wiring and Configuration Diagram

■Cable for Plus CPU (SPC10, NX7, N70plus, N700plus, NX70, NX700)

5 m

2 m

NX-CBLCPU05

NX-CBLCPU02�NX7 PLC (NX7-28ADR, NX7-48ADR...)

�N70plus (CPL9215A, CPL9216A)

�N700plus (CPL7215A)

�NX70p

�NX700p

�SPC10 PLC

1) NX7 PLC

- To interface with Handy-Loader(PGM500)

- To Interface with Computer

2) N70plus, N700plus PLC

- To Interface with Handy-Loader(PGM500)

- To Interface with Computer

3) NX700 PLC

- To Interface with Computer

4) NX70 PLC

- To Interface with Computer

5) PC10 PLC *1

- To Interface with Computer

(RS485/232 Adapter not necessary)

Model Cable Length Contents of Application RemarksApplicable Products

Computer

COM. Cable

PGM-500 Programmer

COM. Cable

Page 74: Oemax Nx Plc

74 I OEMax NX Series

■Cable for SCU Module for N700, NX70, NX700 PLC

■ Extended Motherboard for NX700 PLC

■RS232C Wiring Method (3 line method without FLOW Control)

■Wiring Method of RS485

■Explanation of the Product

1

2

3

5

F.G

TXD

RXD

S.G

PIN No.Signal1

2

3

5

-

RXD

TXD

S.G

PIN No. Signal

Contents of Application

Signal Name

Product NO. Cable Length Applicable Contents Applicable Products

NX-EXPCBL15

NX-EXPCBL08

1.5m

0.8m

Cable to connect when

Motherboard is used

All CPU Models of

NX700 PLC

MnemonicPINNo.

COM Port of SCU Module

COM Port of SCU Module

Communication Wiring Diagram of SCU Module

SCU Module: for NX700 PLC(NX-SCU), for NX70 PLC(NX70-SCU), for N700 PLC(CPL7461)

SCU Unit (9 pin)

17JE-13090-02(D1),DDK(Male)

17JE-23090-02(D1),DDK(Female)

RS232 Device (9 pin)

SCU Unit (9 pin) RS485 Device

RemarksApplicable Module

1

6

7

F.G

485-

485+

PIN No.Signal

485-

485+

Signal

1

2

3

4

5

6

7

8

9

FRAME GROUND

SEND DATA

RECEIVE DATA

-

SIGNAL GROUND

485 TRANSIVER -

485 TRANSIVER +

-

POWER

F.G

TxD

RxD

-

S.G

485 -

485+

-

+5V

NX Series (Cable for Extension and I/O Unit)

These are Cable Harness and Pin Assembly for easy interface with

the external devices at connector type 32 point and 64 point

Modules among I/O Units of SAMSUNG PLSs. (If you experience

any difficulty in purchasing from other manufacturers or direct use,

you are advised to purchase from us for better convenience)

■Cable Harness for Connector Type I/O Unit

케이블하우스 NX70-CBLDCFor DC IN 32 point

For TR OUT 32 point NX70-CBLTR

NX-PIN 20

NX70 PLC N70 PLCN700 PLC

NX-PIN 40

20Pin Ass’y

40Pin Ass’y

NX-CBLRY20

NX-CBLDC

NX-CBLTR

NX-CBLRY

For RELAY OUT 32 point

For DC IN 32, 64 point

For TR OUT 32,64 point

For RELAY OUT 32 point

NX70 PLC

N70 PLC N700 PLC

N700 PLC

NX700 PLC

NX700 PLC

제품종류 적용PLC PLC 제품번호Kinds of Product Applicable PLC Applicable Unit Product NO.

Cable Harness

Pin Ass’y

Page 75: Oemax Nx Plc

External Dimensions

■Diagram of Dimensions for System (mm)

L

P

■Diagram of Motherboard Installation (mm)

P

L

115.5

115.5

27.5

111.0

118.5

Slot TypeDimensions

L P

3 Slot Type

5 Slot Type

8 Slot Type

10 Slot Type

12 Slot Type

205.0

276.0

381.0

452.0

522.0

Unit(mm)

183.8

254.2

359.8

430.2

500.6

SLOT A B

3 Slot Type

5 Slot Type

8 Slot Type

10 Slot Type

12 Slot Type

153.8

224.2

329.8

400.2

470.6

Unit(mm)

81.0

81.0

81.0

81.0

81.0

OEMaxNX Series I 75

NX700 External Dimensions Diagram

Page 76: Oemax Nx Plc

76 I OEMax NX Series

■Diagram of Dimensions for Power Unit (mm)

■Diagram of Dimensions for CPU, I/O and Special Unit (mm)

NX-CPU750B

INI1

NS1RUNRM1PROG

COMRS232C

LINK NO

00 RESET

COM1RS232CRS485

COM2RS232CRS485

0

+

-

FG

100LRS232C

NX-X16D NX-X64D NX-MWLINK NX-SCU

Page 77: Oemax Nx Plc

OEMaxNX Series I 77

2 Slot Type

3 Slot Type

4 Slot Type

5 Slot Type

6 Slot Type

8 Slot Type

10 Slot Type

12 Slot Type

NX70-BASE02

NX70-BASE03

NX70-BASE04

NX70-BASE05

NX70-BASE06

NX70-BASE08

NX70-BASE10

NX70-BASE12

157.2

192.4

227.6

262.8

298.0

368.4

438.8

508.6

128.6

153.8

189.0

234.2

269.4

339.8

410.2

480.6

114.6

149.8

185.0

220.2

255.4

325.8

396.2

466.6

Slot Type Dimensions(B)Dimensions(A)Product NO. Dimensions (C)

■Diagram of Dimensions for System (mm)

A

105.0

88.0

Diagram of External Dimensions for NX70

Page 78: Oemax Nx Plc

78 I OEMax NX Series

■Diagram of Dimensions for Power Unit (mm)

■Diagram of Dimensions for CPU, I/O Special Unit (mm)

INI1

LES1

RUNRM1

20 19 1 2

2 1 19 20

00

LINK NO

RESET

0

+

_

FG

PROG

COMRS232C

COM1RS232CRS485

COM2RS232CRS485

100LRS232C

Page 79: Oemax Nx Plc

OEMaxNX Series I 79

•’ 4.2

81.0

87.0

9.5

1.5

9.5

100.0mm

90.0

3.0

•’ 4.2

126.0

87.0

10.0

1.5

10.0

146.0mm

3.0

■48 Point PLC

■Diagram of Dimensions for Installation

�For 28 Point �For 48 Point

(단위= mm)

■28 Point PLC

Φ4.2 Φ4.2

Diagram of External Dimensions for NX7

DIN Rail for35 mm Mounted

Page 80: Oemax Nx Plc

80 I OEMax NX Series

Unit Name Product Spec. Product Spec. Remarks

High Performance

16k Step Embedded, 0.35㎲/ STEP, 2 Port, PID Auto Tuning Function, Clock Function, Command Word is same with N700a CPU (In case of ExtendedMemory, 32k Step & Comment Memory)

60k Step Embedded, 0.03㎲/ STEP, 2 Port, PID Auto Tuning Function, Clock Function, Comment Memory & EPROM Socket Embedded, Command Word is same with N700a CPU.

120k Step Embedded, 0.03㎲/ STEP, 2 Port, PID Auto Tuning Function, Clock Function, Comment Memory & EPROM Socket Embedded, Command Word is same with N700a CPU.

32k Step Embedded, 0.35㎲/ STEP, 2 Port, PID Auto Tuning Function, Clock Function, Comment Memory & EPROM Socket Embedded, CommandWord is same with N700a CPU.

Floating-Point

Operation

Clock Function

PID AutoTuning

0.001s Timer

■CPU Unit

Unit Name Product Spec. Product Spec. Remarks

Basic Motherboard

NX-BASE03

NX-BASE05

NX-BASE08

NX-BASE10

NX-BASE12

NX-CBLCPU02

NX-CBLCPU05

3 slot type

5 slot type

8 slot type

10 slot type

12 slot type

Common use with BasicMotherboard and extendedMotherboard (No distinction)

■Motherboard

Unit Name Product Code Product Spec. Remarks

Power Supply UnitNX-POWER

NX-PWR220

NX-PWRDC

AC 110/ 220V Free Voltage, 5V 4A, 24V 0.5A

AC 220V Input, 5V 6A

DC 24V Input, 5V 5A DC I/P Type

AC I/P Type

■Power Supply Unit

Unit Name Product Spec. Product Spec. Remarks

General Purpose Use NX-CPU700P 20K Word(Basically Embedded), 0.2㎲/ STEP, 2 Port, PID Function, Clock Function

Unit Name Product Spec. Product Spec. Remarks

Com Cable for

CPUCommunication Cable for NX Series

Common Use with TOOL Port of CPU Modules of NX700

■Communication Cable for CPU Unit

Unit Name Product Spec. Product Spec. Remarks

Extended Memory NX-MEM750A

NX-CPU750A

NX-CPU750B

NX-CPU750C

NX-CPU750D

xtended Memory 16K Step + Comment Memory + EEPROM Socket Embedded For NX-CPU750A

■Memory Unit for CPU750A

유니트명 제품코드 제품사양 비고

증설메모리

유니트명 제품코드 제품사양 비고Unit Name Product Spec. Product Spec. Remarks

General Purpose Use NX-CPU70016K STEP(Basically Embedded), 0.4㎲/ STEP, Trace Function, PID Function,

Comment Memory basically embedded

Product Catalog

NX700 PLC Series

Page 81: Oemax Nx Plc

OEMaxNX Series I 81

I/P Unit

O/P Unit

O/P Unit

16 P

32 P

64 P

16 P

32 P

64 P

NX-X16D

NX-X16A110

NX-X16A220

NX-X32D

NX-X64D

NX-Y16R

NX-Y16RV

NX-Y16T

NX-Y16SSR

NX-Y32T

NX-Y32RV

NX-Y32R

NX-Y64T

NX-DUMMY

DC 12~24V, Terminal Block 20pin, 8 p/ COM, (Polarity +,- Common)

AC 100~120V, Terminal Block 20pin, 8 p/ COM

AC 200~240V, Terminal Block 20pin, 8 p/ COM

DC 12~24V, Connector 40pin, 32 p/ COM, (Polarity +,- Common)

DC 12~24V, Connector 40pin x 2, 32 p/ COM, (Polarity +,- Common)

RELAY O/P, Terminal Block 20pin, 250V 2A, 8 p/ COM

RELAY O/P, Terminal Block 20pin, 250V 2A, 8 p/ COM, with Varistor

TR O/P(NPN), Terminal Block 20pin, 12~24V 0.6A, 8 p/ COM

SSR O/P, Terminal Block 20pin, 100~220V, 0.5A, 8 p/ COM

TR O/P(NPN), Connector 40pin, 12~24V 0.4A, 32 p/ COM

RELAY O/P, Connector 40pin x 1, 250VAC /1A, 32 p/ COM, with Varistor

RELAY O/P, Connector 20pin x 2, 250VAC /1A, 30VDC, 16 p/ COM

TR O/P(NPN), Connector 40pin x 2, 12~24VAC 0.2A, 32 p/ COM

Dummy Unit

Terminal Block Type20pin(Split Type)

Connector Type40pin

Terminal Block Type20pin(Split Type)

Connector Type

Slot Type Product Spec.Product Code Remarks

■I/O Unit

Analog I/P(AD)

Resistance Temperature Detector (RTD)

ThermoCouple I/P

Analog O/P(DA)

NX-AI8V

NX-AI8C

NX-AO4V

NX-AO8V

NX-AO4C

NX-AO8C

NX-RTD4

NX-RTD8

NX-TC4

NX-TC8

8CH,Voltage Input, 16Bit A/D Converter, ±5V, ±10V, 0�5V, 0~10V Resolution (0.153mV~1.0mV), Conversion Speed 1.25ms/Ch

8CH,Current Input, 16Bit A/D Converter, ±20mA, 0�20mA, 4~20mA Resolution (0.519uA~2.0uA) Conversion Speed 1.25ms/Ch

4CH,Voltage Output, 14bit D/A Converter, ±10V, ±5V, 0�10V, 0~5V Resolution (0.305mV~1.0mV), Conversion Speed 2.5ms/ Ch

8CH,Voltage Output, 14bit D/A Converter, ±10V, ±5V, 0�10V, 0~5V Resolution (0.305mV~1.0mV), Conversion Speed 2.5ms/ Ch

4CH,Current Output, 14bit D/A Converter, 0�20mA, 4�20mAResolution (0.037uA~2.0uA) 4uA, Conversion Speed 2.5ms/ Ch

8CH,Current Output, 14bit D/A Converter,, 0�20mA, 4�20mAResolution (0.037uA~2.0uA) 4uA, Conversion Speed 2.5ms/ Ch

4CH,3-Wire Method, Pt100, Pt200, Pt500, Pt1000, JPt100, JPt200, JPt500,JPt1000, NI100, NI120, CU50, 300Ω, 600Ω, 2000ΩResolution 0.1℃, 0.1℉,

8CH,3-Wire Method, Pt100, Pt200, Pt500, Pt1000, JPt100, JPt200, JPt500, JPt1000, NI100, NI120, CU50, 300Ω, 600Ω, 2000ΩResolution 0.1℃, 0.1℉, 10mΩ, 20mΩ, Conversion Speed 60ms/Ch

4CH, Type : B/ R/ S/ N/ K/ E/ J/ T(Temperature Range differs according toSensor Types)

±30mV (1uV /Bit), ±60mV (2uV /Bit)Resolution 0.1℃/ 0.1℉/ 1uV/ 2uV, Conversion Speed 60ms/Ch

8CH,Type : B/ R/ S/ N/ K/ E/ J/ T(Temperature Range differs according toSensor Types)

±30mV (1uV /Bit), ±60mV (2uV /Bit)Resolution 0.1℃/ 0.1℉/ 1uV/ 2uV, Conversion Speed 60ms/Ch

Terminal Block Type20pin(Split Type)

Analog Product Spec.Product Code Remarks

■Analog Unit

Page 82: Oemax Nx Plc

82 I OEMax NX Series

Serial CommunicationUnit (SCU)

NX-SCU

NX-CCU

NX-CCU+

ComputerCommunication

Unit (CCU)

ComputerCommunication

Unit (CCU+)

RS232C/ RS485 x 2Port (Data process with Ladder Program)∙Data Send/Recv enabled with each type of RS232C/ RS485 Device

(Binary/ ASCII Code process) ∙For Interface with Network Inverter and NetworkServo, Network Temperature Controller, etc. ∙Module of existing SDU Function + RS485 Network Function

RS485 Function is added on the existing SDU Function

For Interface withComputer or T/P

For Computer or T/P Interface (For use of CPU700pModule only)

Communication Unit with RS-232C x 1Port Computer and Touch PanelUse C, BASIC Language, "SECTOCOL" N-Series Protocol Basically mounted ①1:1 Leased Communication Unit ②1:N Communication Function: Unit for Interface with Computer on PLC

NETWORK(Optical-LINK, W-LINK)

Communication Unit with RS232C/ RS485 x 1Port Computer and Touch Panel Unit∙NX-CCU+ ↔Computer Communication ( 1:1 or 1:N Communication ) ∙NX-CCU+ ↔Use N-Plus Protocol for Computer Communication ∙NX-CCU+ ↔Communication with Touch Panel, MMI Unit

Unit Name Product Spec.Product Code Remarks

■Communication Unit

HSC Unit

NX-HSC1

NX-HSC2

NX-HSC4

NX-PULSE4

NX-POSI1

NX-POSI2

NX-POSI3

NX-POSI4

1 Axis Type

2 Axis Type

3 Axis Type

4 Axis Type

High PerformanceHSC Unit

Pulse I/OUnit

PositioningUnit

1CH HSC I/P Function 100kcps Binary 24Bit Up/Down Counter(-16,777,216~16,777,215)

2CH HSC I/P Function 100kcps Binary 24Bit Up/Down Counter(-16,777,216~16,777,215)

I/PMode (3 Mode)1) Direction Discrimination Mode2) Individual I/PMode(CW, CCW)3) Phase Difference I/P Mode

(Rotary Encode I/P)

Leased for CPU750Module only

Leased for CPU750Module only

Open Collector /Line Drive Selectable

Leased for CPU750Moduleonly

HSC I/P 4CH, Interrupt I/P 8p, Compared O/P 8 p ∙200kcps, Binary 32Bit Up/Down Counter(-2,147,483,648~2,147,483,647) ∙Multiply Function(1, 2, 4 Multiply), I/P Time Constant Function(4, 8, 16, 32 W/us),

Pulse Width: 2.5us

∙High Speed. High Accuracy Positioning, Pulse Command Method. ∙Line Drive or Open Collector O/P Method selectable ∙Line Drive Method : 1pulse ~ 1M pulse/s ∙Open Collector Method : 1pulse ~ 200k pulse/s ∙With High Speed activation(0.1ms), Tack Time can be reduced. ∙Simple Parameter Setup, Automatic acc/deceleration by Data Setup ∙S-shaped Acc/Deceleration Function, Linear Acc/Deceleration Function ∙E point Control, P point Control, Return to Zero, JOG Drive, ∙Pulse I/P Function: With Pulse I/P Function and Manual Pulse

Generator(MPG Function), Real Time Transmission can be done (Max. 1,000 Multiply according to Multiply Function)

∙Servo Drive, Stepping Drive Interface

Module with diverse functions such as; Pulse O/P 4CH, PWM O/P 4CH, HSC I/P 4CH,Interrupt I/P 8 p, Compared O/P 8 p. ∙Pulse O/P: 100KHz O/P(1Hz Unit ), Direction Discrimination and Individual I/P(CW, CCW)∙PWM O/P: 30KHz O/P(1Hz Unit ), Duty: 0~100% (1% Unit )

Unit Name Product Spec.Product Code Remarks

■Unit for Motion Control

Page 83: Oemax Nx Plc

OEMaxNX Series I 83

MW-Link Unit(Multi Wire-Link)

NX-MWLINK

1) W-Link Function (W Mode) ∙Mount on Basic Motherboard to use ∙Mount up to 3 EA including CCU(5 EA in case of CPU750C Module) ∙Function: PLC Link(16 EA, L: 1,024 p, Ld: 128 Word), Computer Link,

Data Transmission(16Word/ 1Command), Remote Programming, Layer Link(Refer to F145, F146)

∙PLC 32 EA/ Layer, 2 Layer, Transmission Speed : 0.5Mbps ∙Transmission Distance: Total 800m, Interface: RS485 Multi-drop

2) W-Link2 Function (W2 Mode) ∙Mount on Basic Motherboard to use∙Mount up to 3 EA including CCU(8 EA in case of CPU750C Module) ∙Function: PLC Link (32 EA, L: 4,096 p, Ld: 4,096 Word), Computer Link Function,

Data Transmission (1,020Word/1Command), Remote Programming, Layer Link (Refer to F145, F146)

∙PLC 32 EA/ Layer, 2 Layer, Transmission Speed: 0.5Mbps ∙Transmission Distance: Total 800m (up to 1,200 m in case of 250Kbps) ∙Interface: RS485 Multi-drop

Use Twist-Pair Cable Leased forCPU750Module only

Analog Product Spec.Product Code Remarks

■Unit for Network (Open Network)

■REMOTE I/O System

Unit Name Product Spec. Remarks

REMOTE MASTER Unit

REMOTE SLAVE Unit

NX-MASTER

NX-SLAVE

NX70-SLAVE

For use of NX700 PLC

For use of NX700 PLC

For use of NX70 PLC

∙Mount at Basic side, extended side of Motherboard to use(up to 4 EA) ∙Interface up to 32 stations of LAVE Unit per 1 Master ∙Transmission Distance: Total 700m, Transmission Speed: 0.5Mbps

Mount at the location of CPU Unit on the Basic Motherboard.

Product Code

■Unit for Network (Open Network)

Unit Name Product Spec. Remarks

EtherNet Unit NX-ETHERNETLeased for

CPU750Module only

DeviceNet Master Unit for NX700 PLC High Speed Photocoupler, 125K, 250K, 500Kbps, Support S/W : SYCON(NCS-DN) S/W

1) Can be used with 100BASE-TX and 10BASE-T (Conversion executed automatically); Use UTP Cable

2) 10BASE5; Use Transceiver Cable ∙Data Transmission Speed : 100M bit/s (in case of 100BASE-TX) ∙Correspond to TCP/ IP and UDP/ IP, 8 Connection Communication per 1 EA ∙Up to 3 EA EtherNet Module can be mounted on 1 PLC ∙Computer Link. Data Transmission, Permeable Communication, Remote Programming,

Self Diagnosis Function

Product Code

DeviceNet MasterUnit

NX-DEVICE

Page 84: Oemax Nx Plc

84 I OEMax NX Series

NX70 PLC 시리즈

CPU Unit

NX70-CPU750

NX70-CPU70

∙0.35㎲/ STEP, 32k STEP(Basically Embedded), 2 Port, PID AutoTuning Function, Clock Function

∙Comment Memory, EPROM (EEPROM) Operation Function∙High Performance CPU Module

Floating Point OperationClock FunctionPID Auto Tuning

∙0.4㎲/ STEP, 16K STEP(Basically Embedded), Trace Function, PID Function∙Comment Memory Basically Embedded. Communication Pin 9 Pin∙Common CPU Module

Unit Name Product Spec.Product Code Remarks

■CPU Unit (N-Series)

CPU Unit

NX70-CPU70p1

NX70-CPU70p2

∙9.6K STEP(Basically Embedded), 0.2㎲/ STEP, FLASH ROM Embedded ∙Common CPU Module

∙20K STEP(Basically Embedded), 0.2㎲/ STEP, 2 Port, Clock Function, FLASH ROM Embedded, PID Function

∙Advanced CPU Module

Unit Name Product Spec.Product Code Remarks

■CPU Unit (plus-Series)

CommunicationCable CPU Unit

for CPU

NX-CBLCPU02

NX-CBLCPU05

2m

5mNX70, NX700 CPU Unit Communication Cable

Unit Name Product Spec.Product Code Remarks

■CPU Unit Communication Cable

BasicMotherboard

2 Slot Type

3 Slot Type

4 Slot Type

5 Slot Type

6 Slot Type

4 Slot Type

5 Slot Type

6 Slot Type

NX70-BASE02

NX70-BASE03

NX70-BASE04

NX70-BASE05

NX70-BASE06

NX70-BASE08

NX70-BASE10

NX70-BASE12

NX70 PLC has

Basic Motherboard

only

Unit Name Product Spec.Product Code Remarks

■Motherboard

Use WinFPST S/W

Use WinGPC S/W

Caution Product Compatibility between NX70 PLC and N70 PLC1) NX70 PLC and N70 PLC ha no compatibility at all with CPU Unit, Basic Motherboard and Power Unit. (Ladder Programs are mutually compatible) 2) Other I/O Unit and Special Unit, Cables, Programming Device and User Software are mutually compatible.

Power Unit

AC 110/ 220V Free Voltage, 5V 4A, 24V 0.3A

AC 110/ 220V Free Voltage, 5V 4.5A

DC 24V Input, 5V 4.5A

NX70-POWER1

NX70-POWER2

NX70-PWRDC

NX70 PLC has

Basic Motherboard

only

Unit Name Product Spec.Product Code Remarks

■Power Unit

NX70 PLC Series

Page 85: Oemax Nx Plc

OEMaxNX Series I 85

I/P Unit

O/P Unit

Combined Unit

Dummy Unit

16 p

32 p

16 p

32 p

16 p

32 p

NX70-X16D

NX70-X16D1

NX70-X16A110

NX70-X16A220

NX70-X32D

NX70-X32D1

NX70-Y16R

NX70-Y16RV

NX70-Y16T

NX70-Y16SSR

NX70-Y32T

NX70-Y32P

NX70-XY16

NX70-XY32

NX70-DUMMY

DC 12~24V, Terminal Block 20 Pin, 8 p/ COM, (Polarity +,- Common )

DC 24V, Terminal Block 20 Pin, 8 p/ COM, (Polarity +,- Common )

AC 100~120V, Terminal Block 20 Pin, 8 p/ COM

AC 200~240V, Terminal Block 20 Pin, 8 p/ COM

DC 12~24V, Connector 20 Pin x 2, 8 p/ COM, (Polarity +,- Common )

DC 24V, Connector 20 Pin x 2, 8 p/ COM, (Polarity +,- Common )

RELAY O/P, Terminal Block 20 Pin, 250V 1A, 8 p/ COM

RELAY O/P, Terminal Block 20 Pin, 250V 1A, 8 p/ COM, Varistor available

TR O/P(NPN), Terminal Block 20 Pin, 12~24V 0.6A, 8 p/ COM

SSR O/P, Terminal Block 20 Pin, 100~220V, 0.5A, 8 p/ COM

TR O/P(NPN), Connector 20 Pin x 2, 12~24V 0.4A, 16 p/ COM(-)

TR O/P(PNP), Connector 20 Pin x 2, 12~24V 0.4A, 16 p/ COM(+)

.DC12~24V, 8 p, 8 p/ COM, (Polarity +,- Common ),

.RELAY O/P, 8 p, 250V 1A, 8 p/ COM, Terminal Block 20 Pin

.DC12~24V, 16 p, 16 p/ COM, (Polarity +,- Common ), Connector 20 Pin x 2

.TR O/P(NPN) 16 p, ,12~24V 0.4A, 16 p/ COM

Dummy Unit

Terminal Block Type

Connector Type

Terminal Block Type

I/P 8 pO/P 8 p

I/P 16 pO/P 16 p

Connector Type

Slot Type Product Spec.Product Code Remarks

■I/O Unit

Analog I/P(AD)

Resistance TemperatureDetector I/P

(RTD)

Analog O/P(DA)

NX70-AI4V

NX70-AI8V

NX70-AI4C

NX70-AI8C

NX70-AO4V

NX70-AO4C

NX70-AO2V

NX70-AO2C

NX70-RTD4

NX70-RTD8

4CH Voltage Input, 16Bit A/D Converter, ±5V, ±10V, 0�5V, 0�10VResolution (0.153mV~1.0mV), Conversion Speed 1.25ms/Ch

8CH Voltage Input, 16Bit A/D Converter, ±5V, ±10V, 0�5V, 0�10VResolution (0.153mV~1.0mV), Conversion Speed 1.25ms/Ch

4CH Current Input, 16Bit A/D Converter, ±20mA, 0�20mA, 4�20mResolution (0.519uA~2.0uA), Conversion Speed 1.25ms/Ch

8CH Current Input, 16Bit A/D Converter, ±20mA, 0�20mA, 4�20mResolution (0.519uA~2.0uA), Conversion Speed 1.25ms/Ch

4CH Voltage Output, 14bit D/A Converter, ±10V, ±5V, 0�10V, 0�5VResolution (0.305mV~1.0mV), Conversion Speed 2.5ms/ Ch

4CH Current Output, 14bit D/A Converter, 0�20mA, 4�20mAResolution (0.037uA~2.0uA) 4uA, Conversion Speed 2.5ms/Ch

2CH Current Output, 14bit D/A Converter, 0�20mA, 4�20mAResolution (0.037uA~2.0uA) 4uA, Conversion Speed 2.5ms/Ch

2CH Voltage Output, 14bit D/A Converter, ±10V, ±5V, 0�10V, 0�5VResolution (0.305mV~1.0mV), Conversion Speed 2.5ms/Ch

4CH 3-Wire Method, Pt100, Pt200, Pt500, Pt1000, JPt100, JPt200, JPt500, JPt1000, NI100, NI120, CU50, 300Ω, 600Ω, 2000ΩResolution 0.1℃, 0.1℉, 10mΩ, 20mΩ, Conversion Speed 60ms/Ch

8CH 3-Wire Method, Pt100, Pt200, Pt500, Pt1000, JPt100, JPt200, JPt500, JPt1000, NI100, NI120, CU50, 300Ω, 600Ω, 2000ΩResolution 0.1℃, 0.1℉, 10mΩ, 20mΩ, Conversion Speed 60ms/Ch

ThermoCouple I/P

NX70-TC4

NX70-TC8

4CH Type : B/ R/ S/ N/ K/ E/ J/ T(Temperature Range varies according to Sensor Type) ±30mV (1uV /Bit), ±60mV (2uV /Bit)Resolution 0.1℃/ 0.1℉/ 1uV/ 2uV, Conversion Speed 60ms/Ch

8CH Type : B/ R/ S/ N/ K/ E/ J/ T(Temperature Range varies according to Sensor Type) ±30mV (1uV /Bit), ±60mV (2uV /Bit)Resolution 0.1℃/ 0.1℉/ 1uV/ 2uV, Conversion Speed 60ms/Ch

Terminal Block Type20 Pin

(Split Type)

Analog Product Spec.Product Code Remarks

■Analog Unit

(To be released)

(To be released)

Page 86: Oemax Nx Plc

86 I OEMax NX Series

Serial CommunicationUnit (SCU)

ComputerCommunication

Unit (CCU)

NX70-SCU

NX70-CCU

NX70-CCU+

RS232C/ RS485 x 2Port (Data process with Ladder Program) ∙Data Send/Recv enabled with each type of RS232C/ RS485 Device (Binary/ ASCII Code process) ∙For Interface with Network Inverter and NetworkServo, Network Temperature Controller, etc. ∙Module of existing SDU Function + RS485 Network Function.

RS485 Function is added on the existing SDU Function

For Interface with Computer or T/P (for leased use of N-Series)- NX70-CPU70- NX70-CPU750

- NX70-CPU70P1- NX70-CPU70P2

Communication Unit with RS-232C x 1Port Computer and Touch PanelUse C, BASIC Language, "SECTOCOL" N-Series Protocol Basically mounted ①1:1 Leased Communication Unit ②1:N Communication Function: Unit for Interface with Computer

on PLC NETWORK(Optical-LINK, W-LINK)

Unit Name Product SpecProduct Code Remarks

■Communication Unit

HSC Unit

High PerformanceHSC Unit

Pulse I/OUnit

PositioningUnit

NX70-HSC1

NX70-HSC2

NX70-PULSE4

NX70-HSC4

1CH HSC I/P Function(100kcps) + Simplified Pulse O/P Function (200Hz . 40kHz) Binary 24Bit Up/Down Counter(-16,777,216~16,777,215)

2CH HSC I/P Function (100kcps) Binary 24 Bit Up/Down Counter(-16,777,216~16,777,215)

For use of NX70-CPU750,NX70-CPU70p2

For use of NX70-CPU750,NX70-CPU70p2

I/P Mode (3 Mode)1)Direction Discrimination Mode2)Individual I/P Mode(CW, CCW)3)Phase Difference I/P Mode

(Rotary Encode I/P)

HSC I/P 4CH, Interrupt I/P 8p, Compared O/P 8 p �200kcps, Binary 32Bit Up/Down Counter(-2,147,483,648~2,147,483,647) �Multiply Function(1, 2, 4 Multiply), I/P Time Constant Function(4, 8, 16, 32 W/us),

Pulse Width: 2.5us

Module with diverse functions such as; Pulse O/P 4CH, PWM O/P 4CH, HSC I/P 4CH, Interrupt I/P 8 p, Compared O/P 8 p.�HSC I/P: 200kcps, Binary 32Bit Up/Down Counter..... �Pulse O/P: 100KHz O/P(1Hz Unit), Direction Discrimination and Individual I/P(CW, CCW) �PWM O/P: 30KHz O/P(1Hz Unit ), Duty: 0~100% (1% Unit )* Function: NX70-HSC4+Pulse O/P(4CH)+PWM O/P(4CH)

Unit Name Product SpecProduct Code Remarks

■Unit for Motion Control

Communication Unit with RS232C/ RS485 x 1Port Computer and Touch Panel Unit∙NX70-CCU+ ↔ Computer Communication ( 1:1 or 1:N Communication ) ∙NX70-CCU+ ↔ Use N-Plus Protocol for Computer Communication ∙NX70-CCU+ ↔ Communication with Touch Panel, MMI Unit

NX70-POSI2

NX70-POSI4

Open Collector /Line Drive selectable

For use of NX70-CPU750,NX70-CPU70p2

�High Speed. High Accuracy Positioning, Pulse Command Method. �Line Drive or Open Collector O/P Method selectable �Line Drive Method : 1pulse ~ 1M pulse/s �Open Collector Method : 1pulse ~ 200k pulse/s �With High Speed activation(0.1ms), Tack Time can be reduced. �Simple Parameter Setup, Automatic acc/deceleration by Data Setup �S-shaped Acc/Deceleration Function, Linear Acc/Deceleration Function �E point Control, P point Control, Return to Zero, JOG Drive, �Pulse I/P Function: With Pulse I/P Function and Manual Pulse Generator(MPG

Function), Real Time Transmission can be done (Max. 1,000 Multiply accordingto Multiply Function)

�Servo Drive, Stepping Drive Interface

2Axes Type

4Axes Type

Page 87: Oemax Nx Plc

OEMaxNX Series I 87

MW-Link Unit(Multi Wire-Link)

W-Link Unit

NX70-MWLINK

NX70-WLINK

1) W-Link Function (W Mode) �Mount on Basic Motherboard to use�Mount up to 3 EA including CCU �Function: PLC Link(16 EA, L: 1,024 p, Ld: 128 Word), Computer Link, Data Transmission

(16Word/ 1Command), Remote Programming, Layer Link(Refer to F145, F146) �PLC 32 EA/ Layer, 2 Layer, Transmission Speed: 0.5Mbps �Transmission Distance: Total 800m, Interface: RS485 Multi-drop 2) W-Link2 Function (W2 Mode) �Mount on Basic Motherboard to use�Mount up to 3 EA including CCU�Function: PLC Link (32 EA, L: 4,096 p, Ld: 4,096 Word), Computer Link Function, Data Transmission

(1,020Word/1Command), Remote Programming, Layer Link (Refer to F145, F146) �PLC 32 EA/ Layer, 2 Layer, Transmission Speed: 0.5Mbps �Transmission Distance: Total 800m (up to 1,200 m in case of 250Kbps) �Interface: RS485 Multi-drop ※Applicable Model: NX70-CPU750

W-Link Function (W Mode) �Mount on Basic Motherboard to use �Mount up to 3 EA including CCU�Function: PLC Link(16 EA, L: 1,024 p, Ld: 128 Word), Computer Link, Data Transmission

(16Word/ 1Command), Remote Programming, Layer Link(Refer to F145, F146) �PLC 32 EA/ Layer, 2 Layer, Transmission Speed: 0.5Mbps �Transmission Distance: Total 800m, Interface: RS485 Multi-drop ※Applicable Model: NX70-CPU750, NX70-CPU70, NX70-CPU70p2

Use Twisted-PairCable

Use Twist-PairCableLeased used forNX70-CPU750NX70-CPU70p2

Analog Product SpecProduct Code Remarks

■Unit for Network (Network for PLC)

REMOTE I/O SLAVE Unit

NX70-SLAVE -

Mount on the CPU of Motherboard Upper Master Module: Communicate with N700 PLC (CPL7740) and NX700 PLC(NX-MASTER)Module

Kind of Product Product SpecProduct Code (Previous Code) Remarks

■Unit for Network (PLC Network)

DeviceNet Slave Unit for NX70 PLC High Speed Photocoupler, 125K, 250K, 500Kbps, Support S/W: SYCON(NCS-DN) S/W

Unit Name Product SpecProduct Code Remarks

■Unit for Network (Open Network)

DeviceNet Master Unit

NX70-DNS

Page 88: Oemax Nx Plc

88 I OEMax NX Series

Basic Type(10 p)

Basic Type(14 p)

Extension Type

Basic Type(28 p)

Basic Type(48 p)

Basic Type(Analog)

20점 (DCIN 12점, Relay Out 8점)Analog 6점(AD 4CH, DA 2CH)

20점 (DCIN 12점, TR Out 8점)Analog 6점(AD 4CH, DA 2CH)

20점 (DCIN 12점, Relay Out 8점)Analog 4점(AD 4CH)

20점 (DCIN 12점, TR Out 8점)Analog 4점(AD 4CH)

10점 (DCIN 6점, Relay Out 4점)

10점 (DCIN 6점, TR Out 4점)

14점 (DCIN 8점, Relay Out 6점)

14점 (DCIN 8점, TR Out 6점)

28점 (DCIN 16점, TR Out 12점)

28점 (DCIN 16점, Relay Out 12점)

28점 (DCIN 16점, TR Out 12점)

28점 (DCIN 16점, Relay Out 12점)

48점 (DCIN 28점, Relay Out 20점)

48점 (DCIN 28점, TR Out 20점)

48점 (DCIN 28점, Relay Out 20점)

48점 (DCIN 28점, TR Out 20점)

14점 (DCIN 8점, Relay Out 6점)

14점 (DCIN 8점, TR Out 6점)

28점 (DCIN 16점, Relay Out 12점)

28점 (DCIN 16점, TR Out 12점)

NX7S-10ADR

NX7S-10ADT

NX7S-14ADR

NX7S-14ADT

NX7-28ADR

NX7-28ADT

NX7-28DDR

NX7-28DDT

NX7-48ADR

NX7-48ADT

NX7-48DDR

NX7-48DDT

NX7-14EDR

NX7-14EDT

NX7-28EDR

NX7-28EDT

NX7-20ADR-6A

NX7-20ADT-6A

NX7-20ADR-4A

NX7-20ADT-4A

Unit Name Product Code Product Spec Product Spec Remarks

증설모듈

9K 워드(기본내장), 수㎲/ STEP, 2포트(RS232/ 485)AC110�220V Free Voltage, 5V 2.0A, 24V 0.4A

9K 워드(기본내장), 수㎲/ STEP, 2포트(RS232/ 485)DC 24V 입력전원

9K 워드(기본내장), 수㎲/ STEP, 2포트(RS232/ 485)DC 24V 입력전원

9K 워드(기본내장), 수㎲/ STEP, 2포트(RS232/ 485)AC110�220V Free Voltage, 5V 2.0A, 24V 0.4A

9K 워드(기본내장), 수㎲/ STEP, 2포트(RS232/ 485)AC110�220V Free Voltage, 5V 2.0A, 24V 0.4A

2K 워드(기본내장), 수㎲/ STEP, 2포트(RS232/ 485)AC110�220V Free Voltage, 24V 0.3A확장불가

9K 워드(기본내장), 수㎲/ STEP, 2포트(RS232/ 485)AC110�220V Free Voltage, 5V 2.0A, 24V 0.4A

NX7Series(All-in One Type PLC)

Page 89: Oemax Nx Plc

OEMaxNX Series I 89

User S/WWinFPST S/W(for Window)

Unit Name Product Spec Product SpecProduct Code Remarks

■Programming Device �For N-Series, N70, N700, N700a, NX70, NX700 PLC

�N7 PLC�N70 PLC�NX70 PLC�N700, N700H,

N700a�NX700 PLC

Above Windows 95

�Computer S/W with Function of PLC Program Preparation and PLCStatus Check from Computer/ Network Check Function/ I/O MAPand Monitoring , FILE Management/ Storage Function/ ONLINE EditFunction /Error Check Function / TIME CHART Monitoring Function

�Same to the current WinFPST (for Window) Ver 2.xx

User S/WWinGPC

(for Window)

Unit Name Product Spec Product SpecProduct Code Remarks

�For N-plus Series, SPC10, N70plus, N700plus, NX7, NX70(CPU70p), NX700(CPU700p) PLC

�SPC10 PLC�N70plus (CPL9215A)

(CPL9216A)�N700plus (CPL7215A)�NX7 PLC�NX70 PLC (NX70-CPU70p1)

(NX70-CPU70p2) �NX700PLC (NX-CPU700p)

Above Windows 95

�Computer S/W with Function of PLC Program Preparation andPLC Status Check from Computer/ Network Check Function/ I/OMAP and Monitoring , FILE Management/ Storage Function/ONLINE Edit Function /Error Check Function / TIME CHARTMonitoring Function

�Same to the current WinFPST (for Window) Ver 2.xx

CommunicationCable for CPU

NX-CBLCPU02

NX-CBLCPU05

2m

5m

�For SPC10, N70plus, N700plus PLC �For NX7, NX70, NX700 PLC

Common use with CommunicationPorts of NX70, NX700 CPU Unit

Unit Name Corresponding ModelProduct Code Product Spec Remarks

■Cable for Programming

Extension CableNX-EXPCBL15

NX-EXPCBL08

1.5m

0.8mUse for Interface with Extended Motherboard of NX700 Series

Common use with CommunicationPorts of NX70, NX700 CPU Unit

Unit Name Corresponding ModelProduct Code Product Spec Remarks

■Cables for Extension

Page 90: Oemax Nx Plc

90 I OEMax NX Series

I/O Cable ASS'Y

I/O Connector ASS'Y

NX70-CBLDC

NX70-CBLTR

NX-CBLDC

NX-CBLTR

NX-CBLRY

DC IN 32 p Connector Harness

TR OUT 32 p Connector Harness

DC IN 32 p Connector Harness

TR OUT 32 p/ 64 p Connector Harness

RELAY OUT 32 p Connector Harness

20Pin (PIN 20 EA, Connector Hood Included)

40Pin (PIN 20 EA, Connector Hood Included)

NX-PIN20

NX-PIN40

Unit Name Product Code Product Spec Remarks

■I/O Harnesses

NX70 I/O(Connector Type)

NX700 I/O(Connector Type)

NX70 I/O(Connector Type)

NX700 I/O(Connector Type)

Length of Harness 1.5mNO. of Pin: 20 Pin

Length of Harness 1.5mNO. of Pin: 40 Pin

For Connector Type Unit ofNX70, N70, N700 I/O

For Connector Type Unit ofN700 I/O

Remarks �We have N-Series and N-plus Series. Please pay attention because Command language and User S/W is different.)

�DeviceNet Module can be used regardless of N-Series, N-plus Series.

Remark) Order made acceptable if the length of I/O Cable exceeds 1.5m. Please inquire our Head Office if required.

N-Series

N-plus Series

N7 Series

N70 Series

N700 Series

NX70 Series

NX700 Series

SPC10 Series

NX7 Series

N70 Series

N700 Series

NX70 Series

NX700 Series

CPL02323, CPL02343C, CPL02543C.....

CPL9210A, CPL9211A

CPL7210A, CPL7211A, CPL6210A, CPL6210B, CPL6215A

NX70-CPU70, NX70-CPU750

NX-CPU750A, NX-CPU750B, NX-CPU750C, NX-CPU750D, NX-CPU700

SPC-10ADR, SPC-10ADT, SPC-10DR.......

NX7-28ADR, NX7-28ADT, NX7-48ADR, NX7-48ADR.....

CPL9215A, CPL9216A

CPL7215A

NX70-CPU70p1, NX70-CPU70p2

NX-CPU700p

Unit Name Product Code Name of CPU Module Remarks

WinFPST S/W used

WinGPC S/W used