oglaend cable tray

80
Process Power and Marine Division Process, Power and Marine Division SmartPlant 3D (SP3D) Oglaend Cable Ladder & Tray Specifications Oglaend Cable Ladder & Tray Specifications Oglaend Catalogue 2012

Upload: hockchilato

Post on 27-Nov-2015

476 views

Category:

Documents


13 download

DESCRIPTION

SP3D Cable Tray Specfication

TRANSCRIPT

Page 1: Oglaend Cable Tray

Process Power and Marine DivisionProcess, Power and Marine DivisionSmartPlant 3D (SP3D)Oglaend Cable Ladder & Tray SpecificationsOglaend Cable Ladder & Tray Specifications

Oglaend Catalogue 2012

Page 2: Oglaend Cable Tray

SP3D : Contents

• Introduction – Cable Ladder & Cable Tray Slides 3 - 11 Introduction Cable Ladder & Cable Tray Slides 3 11 • OE Cable Ladder System Slides 12 - 22• FOE Cable Ladder System Slides 23 - 33• LOE Cable Ladder System Slides 34 - 46LOE Cable Ladder System Slides 34 46• FTE Cable Tray System Slides 47 - 53• SPB Cable Tray System Slides 54 - 63• SP3D Oglaend Reports Slides 64 - 66SP3D Oglaend Reports Slides 64 66• SP3D Oglaend Specifications Set-up Slides 67 - 78

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 3: Oglaend Cable Tray

SP3D : Oglaend Catalogue

Oglaend Cable Ladder and TraySP3D Specification

SP3D representation

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

representation

Page 4: Oglaend Cable Tray

SP3D : Oglaend Catalogue

Oglaend Cable Ladder and TraySP3D Specification

Th f ll i t ti i d i d tThe following presentation is designed to cover :

An overview of each SP3D Oglaend specification including -

• Design of specifications• Selection of Cable Ladder and Tray types• Loading of particular specification to cover project requirements• Loading of SP3D Oglaend Reports

S3D version required minimum S3D Preferred version SP3D 2009.1 Hot FIX 26 S3D 2011 R1

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 5: Oglaend Cable Tray

SP3D : Oglaend Catalogue

Oglaend Cable Ladder and TraySP3D Specification

Based on SP3D Cable part definition :

– Allowing easy change of SP3D specification– Selection of Cable Ladder and Tray types

L di f i l ifi i j i• Loading of particular specification to cover customer project requirements

– Recommended work flow• Read the following information • Choose the specifications required for your project• Refer to the load instructions at the end of this document

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 6: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder

Oglaend Cable Ladder and TraySP3D Specification

SP3D representation

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 7: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder

Designed to cover OglaendCable Ladder

C bl L dd t U Lidd dCable Ladder systems Un-Lidded

– OE OE-100, OE-125, OE-150 (Heavy Duty)– FOE FOE-70, FOE-100, FOE-150, FOE-150GA– LOE LOE-55, LOE-75, LOE-100 (Medium \ Light duty)

OE

( g y)

– Standard length : 3 metres

– OE offered in material finishes of :• Hot Dipped Galvanized (HDG) FOEHot Dipped Galvanized (HDG)• Stainless Steel (SS)

– LOE offered in material finishes of :• Hot Dipped Galvanized (HDG)

St i l St l (SS)

FOE

• Stainless Steel (SS)• Pre-Galvanized (PG)

– FOE offered in material finishes of:• Polyester Resin

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

All SP3D specification types being designed for open requirements only LOE

Page 8: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder

Designed to cover Oglaend Cable LadderCable Ladder systems Lidded

– OE OE-100, OE-125, OE-150 (Heavy Duty), , ( y y)– FOE FOE-70, FOE-100, FOE-150, FOE-150GA– LOE LOE-55, LOE-75, LOE-100 (Medium \ Light duty)

– Lidded specifications have a CO in their name to designate Covered.– The covers are implied and have no graphical representation

OE

– The covers are implied and have no graphical representation

– Standard length : 3 metres

– OE offered in material finishes of :H t Di d G l i d (HDG) FOE• Hot Dipped Galvanized (HDG)

• Stainless Steel (SS)

– LOE offered in material finishes of :• Hot Dipped Galvanized (HDG)

FOE

( )• Stainless Steel (SS)• Pre-Galvanized (PG)

– FOE offered in material finishes of:• Polyester Resin

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Polyester Resin

All SP3D specification types being designed for open requirements only LOE

Page 9: Oglaend Cable Tray

SP3D : Oglaend Catalogue : IEC Trays

Oglaend Cable Trays SP3D Specification

SP3D representation

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 10: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Cable Trays

Designed to Cover Oglaend Cable trays

Cable Ladder systems Un-Lidded

– FTE FTE-50, FTE-80– SPB SPB-20, SPB-40, SPB-RF

FTE

– FTE offered in material finishes of :• Polyester Resin (C1, C2)

– SPB offered in material finishes of :SPB offered in material finishes of :• Hot Dipped Galvanized (HDG)• Stainless Steel (SS)• Pre-Galvanized (PG)

SPB RF offered in material finishes of:

SPB

– SPB-RF offered in material finishes of:• Hot Dipped Galvanized (HDG)• Stainless Steel (SS)

SPB-RF

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

All SP3D specification types being designed for open requirements only

Page 11: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Cable Trays

Designed to Cover Oglaend Cable trays

Cable Ladder systems Lidded

– FTE FTE-50, FTE-80– SPB SPB-20, SPB-40, SPB-RF

– Lidded specifications have a CO in their name to designate Covered.

FTE

Lidded specifications have a CO in their name to designate Covered.– The covers are implied and have no graphical representation

– FTE offered in material finishes of :• Polyester Resin (C1, C2)

– SPB offered in material finishes of :• Hot Dipped Galvanized (HDG)• Stainless Steel (SS)• Pre-Galvanized (PG)

SPB

( )

– SPB-RF offered in material finishes of:• Hot Dipped Galvanized (HDG)• Stainless Steel (SS)

SPB-RF

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.All SP3D specification types being designed for open requirements only

Page 12: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : OE range

Oglaend OE-100, 125, 150 Ladder specification (Heavy Duty System )

Side rail height : 100mm 125mm 150mm Side rail height : 100mm, 125mm, 150mm Available cabling space : 75mm, 100mm, 125mm Available widths : 150, 300, 450, 600, 750, 900mm

S li d t d d i 3 t l th Supplied as standard in 3 meter lengths Connections by splice plate

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 13: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : OE range

Oglaend open Ladder specification

The specification is designed to place OE fittings in both manual and sketch modes

Understanding of the specification is imperative to efficient construction and material hpurchase

Falling into two remits :

– Sketch mode : being the most effective manner to place– Sketch mode : being the most effective manner to place– Manual mode : used in restricted environments allowing manual modification and

selection of individual fittings

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 14: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : OE range

Oglaend OE open Ladder specification

Designed around a series of specifications :By Material &Height

Cableway selection of Oglaend Specifications

– By Material &Height• OGD_OE-100/125_HDG_ Hot dipped galvanized• OGD_OE-100/125_SS Stainless steel• OGD_OE-150_HDG_ Hot dipped galvanized• OGD_OE-150_SS Stainless steel Selection of Specifications with routing Command

Materials to be loaded are specified in the load file Allocation of Usable Cable Space, defined by specification

Load Width & Depth

Selection Radius with routing Command

Selection of width’s and radius during Placement

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Selection of width s and radius during Placement

Page 15: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : OE range

Oglaend OE open Ladder specification - connecting length to length

OE straight lengths require splice connector for straight to Straight OE straight lengths require splice connector for straight to Straight connections

– when connecting a straight to a straight, two splice plates are generated.g

– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 16: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : OE range

Oglaend OE open Ladder specification - connecting length to fitting

OE straight lengths require splice connector for straight to fitting OE straight lengths require splice connector for straight to fitting connections

– When connecting a straight to a fitting, one splice plate is generated as the fitting is already delivered with a splice plate.g g y p p

– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 17: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : OE range

Oglaend OE open Ladder specification - connecting fitting to fitting

OE fittings require a splice connector for straight to fitting connections OE fittings require a splice connector for straight to fitting connections – When connecting a fitting to a fitting, no splice plate is generated

as each fitting is supplied with the required number splices by Oglaend.Oglaend.

– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 18: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : OE range

The specification is designed to place Oglaend fittings in both manual and sketch modes

Oglaend OE open Ladder specification – Flat Bends

in both manual and sketch modes

Flat bends have fixed angles of 30/45/60/90’

B d il bl ith 600 900 di Bends are available with 600mm or 900mm radius

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 19: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : OE range

Oglaend OE open Ladder specification– Inside or Outside Risers

The specification is designed to place Oglaend fittings in both manual and sketch modesp g p g g

Flexi Risers have variable angles and can be used for 30/45/60/90’. Number of segments may differ per angle & radius.

Riser radius should set prior to placementFlexi RiserRiser radius should set prior to placement

Flexi Risers should be placed manually to ensure correct selection Combi Risers are available for 90 and 45deg vertical bends

Riser

Combi Riser

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 20: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : OE range

The specification is designed to place Oglaend fittings in both manual and sketch modes

Oglaend OE open Ladder specification – Equal & Unequal Tees

manual and sketch modes

Fixed Tees and Unequal tees have are available in 600mm and 900mm radius.

Manual placement allows selection of specific fittingsManual placement allows selection of specific fittings

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 21: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : OE range

Oglaend OE open Ladder specification– Left Hand & Right Hand Reducers

The specification is designed to manually place Oglaend offset reducer fittings. Automatic placement is not valid.

Ri ht H d R d

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Left Hand ReducerRight Hand Reducer

Page 22: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : OE range

The specification is designed to manually place Oglaend C fitti A t ti l t i t lid

Oglaend OE open Ladder specification– Equal Crosses

Cross fittings. Automatic placement is not valid.Available in 600mm and 900mm radius.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 23: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : FOE range

Oglaend FOE-100, 125, 150 Ladder specification

Side rail height : 70mm 100mm 150mm Side rail height : 70mm, 100mm, 150mm Available cabling space : 46mm, 71mm, 121mm Available widths : 150, 200, 300, 400, 450, 500, 600mm

S li d t d d i 3 t l th Supplied as standard in 3 meter lengths Connections by splice plate

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 24: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : FOE range

Oglaend open Ladder specification

The specification is designed to place FOE fittings in both manual and sketch modes

Understanding of the specification is imperative to efficient construction and material hpurchase

Falling into two remits :

– Sketch mode : being the most effective manner to place– Sketch mode : being the most effective manner to place– Manual mode : used in restricted environments allowing manual modification and

selection of individual fittings

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 25: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : FOE range

Oglaend OE open Ladder specification

Designed around a series of specifications :By Material &Height

Cableway selection of Oglaend Specifications

– By Material &Height• OGD_FOE-70_C2 Polyester Class 2• OGD_FOE-100_C1 Polyester Class 1• OGD_FOE-150_C1 Polyester Class 1• OGD_FOE-150_GA_C1 Polyester Class 1 Selection of Specifications with routing Command

Materials to be loaded are specified in the load file Allocation of Usable Cable Space, defined by specification

Load Width & Depth

Selection Radius with routing Command

Selection of width’s and radius during Placement

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Selection of width s and radius during Placement

Page 26: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : FOE range

Oglaend FOE open Ladder specification - connecting length to length

FOE straight lengths require splice connector for straight to Straight FOE straight lengths require splice connector for straight to Straight connections

– when connecting a straight to a straight, two splice plates are generated.g

– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 27: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : FOE range

Oglaend FOE open Ladder specification - connecting length to fitting

FOE straight lengths require splice connector for straight to fitting FOE straight lengths require splice connector for straight to fitting connections

– When connecting a straight to a fitting, two splice plates are generated.g

– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 28: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : FOE range

Oglaend FOE open Ladder specification - connecting fitting to fitting

FOE fittings require a splice connector for straight to fitting FOE fittings require a splice connector for straight to fitting connections

– When connecting a fitting to a fitting, two splice plates are generated.generated.

– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 29: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : FOE range

The specification is designed to place Oglaend fittings in both manual and sketch modes

Oglaend FOE open Ladder specification – Flat Bends

in both manual and sketch modes

Flat bends have fixed angles of 45/90deg

B d il bl i 300 di Bends are available in 300mm radius

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 30: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : FOE range

Oglaend FOE open Ladder specification– Inside or Outside Risers

The specification is designed to place Oglaend fittings in both manual and sketch modesp g p g g

Flexi Risers have variable angles and can be used for 30/45/60/90’. Number of segments may differ per angle & radius.

Riser Radius 400, 600, 800mm available. Riser radius should set prior to placementRiser Radius 400, 600, 800mm available. Riser radius should set prior to placement Flexi Risers should be placed manually to ensure correct selection

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 31: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : FOE range

The specification is designed to place Oglaend fittings in both manual and sketch modes

Oglaend FOE open Ladder specification – Equal Tees

Fixed Tees are available in 300mm radius.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 32: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : FOE range

Oglaend FOE open Ladder specification– Left Hand & Right Hand and Central Reducers

The specification is designed to manually place Oglaend offset reducer fittings manually.Standard and plate type (part) reducers are available Central Reducers can be placed Automatically or manually

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Offset Reducer Central Reducer Reducer Part

Page 33: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : FOE range

The specification is designed to manually place Oglaend Cross fittings. Automatic placement is not valid.A il bl i 300 di

Oglaend FOE open Ladder specification– Equal Crosses

Available in 300mm radius.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 34: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : LOE range

Oglaend LOE-55, 75, 100 Ladder specification (Medium \ Light Duty System )

Side rail height : 55mm 75mm 100mm Side rail height : 55mm, 75mm, 100mm Available cabling space : 24mm, 46mm, 68mm Available widths : 200, 300, 400, 500, 600mm

S li d t d d i 3 t l th Supplied as standard in 3 meter lengths Connections by splice plate

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 35: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : LOE range

Oglaend open Ladder specification

The specification is designed to place LOE fittings in both manual and sketch modesp g p g

Understanding of the specification is imperative to efficient construction and material purchaseF lli i i Falling into two remits :

– Sketch mode : being the most effective manner to place– Manual mode : used in restricted environments allowing manual modification and

selection of individual fittingsselection of individual fittings

– Note the following information for LOE specifications :100mm must be added to the straight length to accommodate fitting to straight g g g gjoints. This is to allow for the straight insertion depth when a straight is connected to a Tee, Flat Bend or Cross. For example, a straight length between two flat bends means a total of 200mm being added to the straight length

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

being added to the straight length.

Page 36: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : LOE range

Oglaend LOE open Ladder specification

Designed around a series of specifications :By Material &Height

Cableway selection of Oglaend Specifications

– By Material &Height• OGD_LOE_HDG_ Hot dipped galvanized• OGD_LOE_SS Stainless steel• OGD_LOE-PG_ Pre-galvanized

Selection of Specifications with routing Command

Materials to be loaded are specified in the load file Allocation of Usable Cable Space, defined by specification

L d Wid h & D hLoad Width & Depth

Selection Radius with routing Command

Selection of width’s and radius during Placement

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 37: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : LOE range

Oglaend LOE open Ladder specification - connecting length to length

LOE straight lengths require splice connector for straight to Straight connections

– when connecting a straight to a straight, two splice plates are g g g , p pgenerated.

– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear

li lon a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 38: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : LOE range

Oglaend LOE open Ladder specification - connecting length to fitting

LOE straight lengths require splice connector for straight to fitting LOE straight lengths require splice connector for straight to fitting connections

– When connecting a straight to a fitting, no splice plate is generated as the fitting is already delivered with a splice plate.g g y p p

– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 39: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : LOE range

Oglaend LOE open Ladder specification - connecting fitting to fitting

LOE fittings require a splice connector for straight to fitting LOE fittings require a splice connector for straight to fitting connections

– When connecting a fitting to a fitting, two splice plate are generated as each fitting is supplied with the required numbergenerated as each fitting is supplied with the required number splices by Oglaend.

– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 40: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : LOE range

The specification is designed to place Oglaend fittings in both manual and sketch modes

Oglaend LOE open Ladder specification – Flat Bends

in both manual and sketch modes

Flat bends are available in 90deg angles

B d il bl ith 300 di Bends are available with 300mm radius

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 41: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : LOE range

Oglaend LOE open Ladder specification– Inside or Outside Risers

The specification is designed to place Oglaend fittings in both manual and sketch modesp g p g g Risers are available for 45 and 90deg bends. LOE 50 has 45deg Riser brackets. LOE 100 has Combi Risers for 45 and 90deg bends

Riser Bracket Combi Riser

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 42: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : LOE range

The specification is designed to place Oglaend fittings in both manual and sketch modes

Oglaend LOE open Ladder specification – Equal Tees

Fixed Tees are available in 300mm radius.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 43: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : LOE range

The specification is designed to manually place Oglaend Cross fittings. Automatic placement is not valid.A il bl i 300 di

Oglaend LOE open Ladder specification– Equal Crosses

Available in 300mm radius.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 44: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : FTE range

Oglaend FTE-50, 80 Tray specification

Side rail height : 50mm 80mm Side rail height : 50mm, 80mm Available cabling space : 47mm, 77mm Available widths : 50, 100, 150, 200, 300, 400mm

S li d t d d i 3 t l th Supplied as standard in 3 meter lengths Connections by splice plate

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 45: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : FTE range

Oglaend open Ladder specification

The specification is designed to place FTE fittings in both manual and sketch modes

Understanding of the specification is imperative to efficient construction and material hpurchase

Falling into two remits :

– Sketch mode : being the most effective manner to place– Sketch mode : being the most effective manner to place– Manual mode : used in restricted environments allowing manual modification and

selection of individual fittings

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 46: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : FTE range

Oglaend FTE open Ladder specification

Designed around a series of specifications :By Material &Height

Cableway selection of Oglaend Specifications

– By Material &Height• OGD_FTE_C2 Polyester class 2• OGD_FTE_C1 Polyester class 1

Selection of Specifications with routing Command

Materials to be loaded are specified in the load file Allocation of Usable Cable Space, defined by specification

L d Wid h & D hLoad Width & Depth

Selection Radius with routing Command

Selection of width’s and radius during Placement

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 47: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : FTE range

Oglaend FTE open Ladder specification - connecting length to length

FTE straight lengths require splice connector for straight to Straight FTE straight lengths require splice connector for straight to Straight connections

– when connecting a straight to a straight, two splice plates are generated.g

– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 48: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : FTE range

Oglaend FTE open Ladder specification - connecting length to fitting

FTE straight lengths require splice connector for straight to fitting FTE straight lengths require splice connector for straight to fitting connections

– When connecting a straight to a fitting, one splice plate is generated as the fitting is already delivered with a splice plate.g g y p p

– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 49: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : FTE range

Oglaend FTE open Ladder specification - connecting fitting to fitting

FTE fittings require a splice connector for straight to fitting FTE fittings require a splice connector for straight to fitting connections

– When connecting a fitting to a fitting, no splice plate is generated as each fitting is supplied with the required number splices byas each fitting is supplied with the required number splices by Oglaend.

– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 50: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : FTE range

The specification is designed to place Oglaend fittings in both manual and sketch modes

Oglaend FTE open Tray specification – Flat Bends

in both manual and sketch modes

Flat bends have fixed angles of 45 and 90deg

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 51: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : FTE range

Oglaend FTE open Tray specification– Inside or Outside Risers

The specification is designed to place Oglaend fittings in both manual and sketch modesRi h fi d l f 45 d 90d Risers have fixed angles of 45 and 90deg.

45deg Risers are Splice Angles. 90deg Risers are Combi Risers.

Splice Angle 45degCombi Riser

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 52: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : FTE range

The specification is designed to place Oglaend Tee fittings in both manual and sketch modes

Oglaend FTE open Tray specification – Equal Tee’s

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 53: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Ladder : FTE range

Oglaend FTE open Ladder specification– Left & Right Hand Simple Reducers

The specification is designed to manually place Oglaend offset reducer fittings. Automatic placement is not valid.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Left Hand ReducerRight Hand Reducer

Page 54: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : SPB range

Oglaend SPB-20, 40, SPB-RF Tray specification

Side rail height : 20mm 40mm Side rail height : 20mm, 40mm Available cabling space : 18mm, 18.5mm, 38.5mm Available widths : 50, 100, 150, 200, 300, 400, 500, 600mm – SPB-20

A il bl idth 50 100 150 200 300 400 SPB 40 Available widths : 50, 100, 150, 200, 300, 400mm – SPB-40 Available widths : 50, 100, 150, 200, 300, 400, 500, 600mm – SPB-RF Supplied as standard in 3 meter lengths

C ti b li l t Connections by splice plate

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 55: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : SPB range

Oglaend open Ladder specification

The specification is designed to place SPB fittings in both manual and sketch modes

Understanding of the specification is imperative to efficient construction and material hpurchase

Falling into two remits :

– Sketch mode : being the most effective manner to place– Sketch mode : being the most effective manner to place– Manual mode : used in restricted environments allowing manual modification and

selection of individual fittings– Note the following information for SPB specifications :g

55mm must be added to the straight length to accommodate fitting to straight joints. This is to allow for the straight insertion depth when a straight is connected to a Tee, Flat Bend or Cross. For example a straight length between two flat bends means a total of 110mm

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

For example, a straight length between two flat bends means a total of 110mm being added to the straight length.

Page 56: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : SPB range

Oglaend SPB open Ladder specification

Designed around a series of specifications :B M i l &H i h

Cableway selection of Oglaend Specifications

– By Material &Height• OGD_SPB_HDG_ Hot dipped galvanized• OGD_SPB_SS Stainless steel• OGD_SPB_PG Pre-Galvanized (straights only)• OGD SPB-RF HDG Hot dipped galvanized Selection of Specifications with routing Command_ _ _ pp g• OGD_SPB-RF_SS Stainless steel

Materials to be loaded are specified in the load file Allocation of Usable Cable Space, defined by specification

Load Width & Depth

Selection Radius with routing Command

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Selection of width’s and radius during Placement

Page 57: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : SPB range

Oglaend SPB open Ladder specification - connecting Straight to Straight SPB straight lengths require splice connector for straight to Straight

connectionsconnections – when connecting a straight to a straight, two splice plates are generated.– The splice plates are not modeled or detailed in the SP3D parts list but are

controlled by a specification level rule and will appear on a splice plate y p pp p preport.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 58: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : SPB range

Oglaend SPB open Ladder specification - connecting Straight to fitting

SPBE straight lengths require splice connector for straight to fitting SPBE straight lengths require splice connector for straight to fitting connections

– When connecting a straight to a fitting, one splice plate is generated as the fitting is already delivered with a splice plate.g y p p

– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 59: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : SPB range

Oglaend SPBE open Ladder specification - connecting fitting to fitting

SPB fittings require a splice connector for straight to fitting connections SPB fittings require a splice connector for straight to fitting connections – When connecting a fitting to a fitting, no splice plate is generated as

each fitting is supplied with the required number splices by Oglaend.The splice plates are not modeled or detailed in the SP3D parts list but– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 60: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : SPB range

The specification is designed to place Oglaend fittings in both manual and sketch modes

Oglaend SPB open Ladder specification – Flat Bends

in both manual and sketch modes

Flat bends have fixed angles of 45/90deg Flexi Bends can be used for 30/45/90deg angles

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 61: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : SPB range

Oglaend SPB open Ladder specification– Inside or Outside Risers

The specification is designed to place Oglaend fittings in both manual and sketch modes

Flexi Risers have variable angles and can be used for 30/45/90deg Flexi Risers should be placed manually to ensure correct selection

Flexi Riser Flexi Risers should be placed manually to ensure correct selection

Combi Risers are available for 90deg vertical bends

Riser

Combi Riser

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 62: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : SPB range

The specification is designed to place Oglaend fittings in both manual and sketch modes

Oglaend SPB open Ladder specification – Equal Tees

manual and sketch modes

Tees are available with a 75mm radius.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 63: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Tray : SPB range

Oglaend SPB open Ladder specification– Central Left and Right Hand Reducers

The specification is designed to manually place Oglaend central and offset reducer fittings. Automatic placement of offset reducers is not valid.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Left Hand Reducer Central Reducer

Page 64: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Reporting

Oglaend Cable Ladder & Tray SP3D Specification - Reporting

3 Reports supplied:

Oglaend Fittings Reportg g pOglaend Cover ReportOglaend Splice Report

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

SP3D representation

Page 65: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Reporting

Oglaend Ladder and Tray reporting from SP3DOpen SP3DSelect> Tools > Run reportsp

Note: Reports can also be run from the Drawings and Reports Task

Select > Your system Select> OK

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 66: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Reporting

Output format: Excel spread Sheet

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 67: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Setup

Oglaend Cable Ladder & Tray SP3D Specification - Set up

SP3D

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

SP3D representation

Page 68: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Setup

Loading SP3D Specifications

Process Stages:Process Stages:

Creating SP3D Catalogue (optional for existing project ) Loading SP3D symbols Project Creation (Optional not covered in document) Updating the Catalogue with the particular specification files

R l ti S ifi ti t SP3D t Relating Specification to SP3D systems

Setting up delivered reports

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 69: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Setup

Supplied data directories :

Oglaend Final Deliverables

\SmartPlant

\FOE Final Deliverable (Contains FOE specifications, code lists and custom symbols)

\FTE Final Deliverable (Contains FTE specifications , code lists and custom symbols)

\LOE Final Deliverable (Contains LOE specifications, code lists and custom symbols)

\OE Final Deliverable (Contains OE specifications , code lists and custom symbols)\OE Final Deliverable (Contains OE specifications , code lists and custom symbols)

\SPBE Final Deliverable (Contains SPBE specifications, code lists and custom symbols)

\Reports (Contains Custom report templates and DLL)

\PPTS (General overview of use and how to load)

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 70: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Setup

Loading SP3D specification

Please consider the following before loading Oglaend specifications:g g g p

Loading into clean specification catalog Means only the new specification loaded for Oglaend can be used

• Use only specifications for project• Avoids causal users selecting an incorrect Specifications

– Loading into clean database takes time but will not include other disciplines - piping, structural etc– Recommend you load into standard database and just remove additionally supplies specifications– Recommend you load into standard database and just remove additionally supplies specifications

Using and existing specificationNormal to use for change from one specification to another– Normal to use for change from one specification to another

• Allows change from existing specification to another

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 71: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Setup

Creating SP3D catalogue

Building your SP3D reference databaseSelect > SP3D PROJECT MANAGERSelect > Database > New > catalogSelect > Database > New > catalogEnter your data :

Catalogue name : OGD_cdb (or whatever you prefer)(recommend that you add _CDB at the end)

Catalogue schema name : ensure this is unique in your database

Template file : point to your default template supplied “Apprepos.dat” for clean or

“Catalogue.dat” for standard product (best option)

Database Templates will be found in the 3dRef product directory

SharedContent Folder

(Do not use product directories for working project)(Do not use product directories for working project)

Normal SP3d Administrator function Associate your catalog to the SmartPlant 3d Project.

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 72: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Setup

Creating SP3D loading specification - Obtaining the latest symbols

O Y t tOpen Your ecustomer account:

Select > Software downloads > ProductsSelect > SmartPlant 3DSelect > SmartPlant Enterprise Content for SmartPlant 3DSelect > software version - choose version – Strongly recommended is version 2011 R1 and aboveSelect > Cable tray

Save to the Symbol directory and following next instructions.

Note. Ecustomer is upgraded monthly

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 73: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Setup

Creating SP3D loading specification

Before loading the specification the custom symbols must betransferred to the plant catalogues sharedContent folder.

Copy : Symbol IconsFOE Final Deliverable\Symbols\Symbol Icon's

To \ SharedContent\SymbolIcons\

AND : symbols dll’s

FOE Final Deliverable\Symbols\Symbol DllTo

\SharedContent\Custom Symbols

Repeat this procedure for the other specifications in this delivery.Ie

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

OE Final Deliverable

Page 74: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Setup

Creating SP3D loading specification

Registration of the new symbols:

Open SP3D Project managerSelect > Reference Data (then the plants Catalog )Select > Tools > Update Custom Symbol Configuration.

NoteDo not move on to next step if this has not been completed

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 75: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Setup

Creating SP3D loading specification

With starting specification catalogue or Clean catalogue with previous screen completed Or Working catalogueBulk load Specifications

Open Intergraph SmartPlant 3dOpen Intergraph SmartPlant 3d >Database Tools>Bulk load reference data You can find these file in the following directories :

Specification\Data\Part Data or Specification\Data\Codelist

File Type File name Required Load Function

Excel Code list Allcodelists-FOE

Required by Spec. Manufacture, material, span

Excel Code list CableTraySelect Lists

Required by Spec. Cable Part Data Basis

Excel (Spec) Only load the specifications you

i

Oglaend_FOE-2011

Required by Spec. Delivered spec and fittings

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

require.

Page 76: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Setup

Creating SP3D loading specification

Reviewing you log files;

It is always important to check your log file after the load process : you should expect to see some warning messages relating to items existing this is due to the system telling you that item in the code list exist already these are not of concern:

– Expect

WARNING: cannot create object . Object already exists in the database .SkippedWARNING: cannot create object . Object already exists in the database .Skipped– This is normally and relates to “class node” or Part Class where the each a part will try to create even

though all items require this and it has been created previously. Exists or created is acceptable

– Items to watch for :

• WARNING : Failed to set the Symbol Icon property. gif file is missingThe icon and symbol “dll” where not loaded and update :- contact local Intergraph Support

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 77: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Setup

Systems & SpecificationsOpen SP3D : Select > Task > Systems & SpecificationsSelect > Highest level ( Oglaend)Select > Define allowed specification

Select > Specifications to relate to electrical systems

Note. These may be removed / sub selected at the system Level.

Loading all specifications on previous selection adds lost of parts to the database and should be avoided if not required

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 78: Oglaend Cable Tray

SP3D : Oglaend Catalogue : Setup

The setup of the SP3D Oglaend reports consist of four main steps:

Loading SP3D Oglaend Custom SP3D reports

1, Copying of the Ogleand Report Templates to the catalog SharedContent Reports folder.

2, Bulkloading the supplied Reports workbook. This contains the Oglaend custom report definitions.

3 Creation of 3 Catalog Report filters3, Creation of 3 Catalog Report filters Oglaend Fittings Oglaend Cover PartsOglaend Splice Parts

4 R i t ti f th t R t DLL4, Registration of the custom Report DLL

This process is detailed in the supplied Report Setup document which is found in the Oglaend Final Deliverables\Reports folder

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 79: Oglaend Cable Tray

I t ti th Integrating the Engineering Engineering Enterprise…

© 2012. Intergraph Process, Power & Marine. All Rights Reserved.

Page 80: Oglaend Cable Tray

Process, Power and Marine Division

F i f ti i th UK t tFor more information in the UK contact:

Telephone : 01793-619999

Fax : 01793-492975

Web : www.intergraph.co.uk

www.oglaend-system.com