okolab · 2019. 4. 9. · • trimmed 24mm diameter circular observation opening for imaging in the...

44
www.oko-lab.com OKOLAB IVF CATALOG OKOLAB IVF

Upload: others

Post on 29-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

www.oko-lab.com

OKOLABIVF CATALOG

OKOLABIVF

IVF catalog.indb 1 21/06/2018 13:19:30

Page 2: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

IVF catalog.indb 2 21/06/2018 13:19:47

Page 3: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

Warm plates for Nikon ....................................page 8

Temperature controllers ..................................page 4

Warm plates for Olympus .................................page 16

Leo portable meter ........................................page 30

Warm plates for Leica .....................................page 22

Warm plates for Zeiss .....................................page 26

Table of Content

Tri-Gas mixer ...............................................page 34

Gas Controllers for cell culture incubators ............page 36

IVF catalog.indb 3 21/06/2018 13:19:47

Page 4: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

4

Temperature Controllers

H401-T-CONTROLLER

H401-T-CONTROLLER is a 2-channel controller which can be employed to control up to two devices at the same time.The devices are connected to the controller with fast connectors and can be easily replaced.The controller is equipped with a 4.3’’ Touch Screen and an intuitive software to off er accuracy and simplicity of useat the same time.The external sensor allows to automatically and independently calibrate the devices by performing the self calibration routine.A password protected procedure allows to calibrate the controller and the sensors for periodic maintenance.The controller is equipped with local memory for on-board data logging and storage of calibration and alarms events.

The GLASS PLATE can be automatically calibrated by employing the external temperature sensor of the con-troller an by starting the self calibration routine from the touch screen.The algorithm will progressively increase the tempera-ture of the plate until the desired set point temperature is reached inside the calibration Petri.

• H401-T-CONTROLLER can control up to 2 devices• Set point value from room temperature to 60°C• T - accuracy on specimen: ± 0.3°C, after self calibration routine• Intuitive 4.3’’Touch Screen Display• External k-type thermocouple for self calibration• Independent calibration of the devices connected• Start up protocol with tunable heating rate (°C/min)• On-board Data Logging / Download via mini-USB• Alarm buzzer and External Alarm Connector• Password protected procedure for periodic calibration against certifi ed thermometer• Dimensions: 103x130x59 mm

GLASS PLATE CALIBRATION

FEATURES

IVF catalog.indb 4 21/06/2018 13:19:47

Page 5: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

5

Temperature Controllers

T-Controller.Controls up to two devices

T-sensor for auto-matic plate cali-bration

H401-Glass Table

On board memory for Data Logging with USB option

T-PAD + Glass Plate

FEATURRESH401-T-CONTROLLER can be connected to any of these devices (maximum two devices can be controlled at the same time): • H601 GLASS PLATES series• H401 GLASS PLATES series• H401 METAL PLATES series• H401 GLASS TABLE • H401 T PAD series• H401 STAGE T PAD (clamp on stage

T-PAD)• OBJECTIVE HEATER

IVF catalog.indb 5 21/06/2018 13:19:48

Page 6: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

6

Temperature Controller

H401-T-PENNY

H401-T-PENNY is a compact single-channel Temperature Controller compatible with OKOLAB single-channel metal and glass heated plates and heated objective collars.

H401-T-PENNY combines performance and simplicity at an aff ordable price.

FEATURES• Temperature range: from ambient to 60°C• T - accuracy on specimen: ± 0.3°C• Single Channel• One-Point Temperature Calibration and Adjustment• Dim.: 84x45x20 mm• Weight: 47.5 g

Penny+ Glass Table

Penny+T Glass Plate

Penny+T PAD

IVF catalog.indb 6 21/06/2018 13:19:50

Page 7: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

7

NOTES

IVF catalog.indb 7 21/06/2018 13:19:51

Page 8: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

8

02

Warm ITO glass plate for Nikon stage T/TI-SR and TI-SP - Flat - 108 mm diameter - Heated Glass and Frame

Features:• ITO (Iridium Tin Oxide) coated glass plate fi ts in the circu-

lar opening of the XY stage and creates a fl at temperature controlled surface, fl ush with the rest of the XY stage.

• Dragontrail®: Chemically strengthened, scratch resistant, glass.• Heated aluminum frame: Provides the highest tempera-

ture uniformity by warming up both, the ITO coated glass and the surrounding aluminum circular case.

• Glass thickness 0.5 mm• Plate diameter 108mm

Requires one of the following controllers: • H401-T-CONTROLLER (one channel controls the glass and the oth-

er channel controls the aluminum case) – suggested controller.

ø107

.95

64.6

64.6

H601-NIIKON-TI-SSR-GLASS//FRAME

T/TI

-SR

and

TI-S

PT/

TI-S

R an

d TI

-SP

Warm ITO glass plate for Nikon stage T/TI-SR and TI-SP - Flat - 108 mm diameter

Features:• ITO (Iridium Tin Oxide) coated glass plate. Fits in the circu-

lar opening of the XY stage and creates a fl at temperature controlled surface, fl ush with the rest of the XY stage.

• Dragontrail®: Chemically strengthened, scratch resistant, glass.

• Glass thickness 0.5 mm• Plate diameter 108mm

Requires one of the following controllers: • H401-T-CONTROLLER• H401-T-PENNY

ø107

.95

64.6

64.6

H6001-NIKON-TI-SR-GLLASS

T/TI

-SR

and

TI-S

PT/

TI-S

R an

d TI

-SP

Warm metal plate for Nikon stage T/TI-SR and TI-SP with circular opening - Flat - 108 mm diameter

Features:• Fits in the circular opening of the XY stage and creates a

fl at temperature controlled surface, fl ush with the rest of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lenses• Plate diameter 108mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

ø107

.95

ø24

20

H4011-NIKON--TI-SR-MMETAL

T/TI

-SR

and

TI-S

PT/

TI-S

R an

d TI

-SP

H4011-NIKONN-TI-SR-TT--PADHeated Flat Plate for Nikon stage T/TI-SR

with circular openingFeatures:

• The plate clumps on the stage and provides a heated fl at surface throughout the entire surface of the stage

• Does not cover the circular opening• Compatible with H401-NIKON-TI-SR-METAL and H601-

NIKON-TI-SR-GLASS• Rises the focal of the XY stage by: 2.5 mm• Flat surface throughout the stage• Compatible with glass and metal heating inserts

Requires one of the following controllers: • H401-T-CONTROLLER. Required controller when in combi-

nation with H401-NIKON-TI-SR-METAL or H601-NIKON-TI-SR-GLASS

• H401-PENNY

T/TI

-SR

and

TI-S

PT/

TI-S

R an

d TI

-SP

230

323

9,20

ø230

3,50

Nikon - Inverted

IVF catalog.indb 8 21/06/2018 13:19:51

Page 9: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

9

H401-NIKON--TS2R-MEETALWarm metal plate for Nikon stages TC-S-SR,

TC-S-SRF and TS2-S-SM Features:

• This metal plate fi ts in the opening of the XY stage and creates a fl at temperature controlled surface at the same height as the rest of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

TC-S

-SR,

TC-

S-SR

F TC

-S-S

R, T

C-S-

SRF

and

TS2-

S-SM

and

TS2-

S-SM

H6011-NIKONN-TS2R-GLLASSWarm ITO glass plate for Nikon stages TC-S-SR, TC-S-SRF

and TS2-S-SM Features:

• ITO (Iridium Tin Oxide) coated glass plate. Fits in the opening of the XY stage and creates a fl at temperature controlled surface, fl ush with the rest of the XY stage Alu-minium frame for superior resistance and fl atness

• Dragontrail®: Chemically strengthened, scratch resistant, glass.

• Aluminium frame for superior resistance and fl atness• Glass thickness 0.5 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-T-PENNY

TC-S

-SR,

TC-

S-SR

F TC

-S-S

R, T

C-S-

SRF

and

TS2-

S-SM

and

TS2-

S-SM

62 85,4

100,40127,65

100,

68

85,8

5

ø24

H601-NNIKON-TS22R-METALL/GLASSWarm metal and ITO glass plate

for Nikon stage TS2(R) Features:

• Fits in the opening of the TS2(R) stage and creates a fl at temperature controlled surface

• Dragontrail®: Chemically strengthened, scratch resistant, glass.

• Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate

• Compatible with oil immersion lenses• Metal and glass sides have independent temperature con-

trolRequires one of the following controllers:

• H401-T-CONTROLLER (one channel controls the glass side and the other channel controls the aluminum side)

68

6.630

ø2464

Ecpl

ipse

wit

h N

I-S-

EEc

plip

se w

ith

NI-

S-E 128.86

85.8

5

H4011-NIKONN-TS2R-T--PADHeated Flat Plate

for Nikon stage TS2(R)

Features:• The plate clumps on the Nikon stages TC-S-SR, TC-S-SRF

and TS2-S-SM and provides uniform heating throughout the entire surface of the stage

• Does not cover the TS2R opening• Compatible with H601-NIKON-TS2R-GLASS and H401-

NIKON-TS2R-METAL• This plate rises the focal of the XY stage by: 5 mm• Flat surface throughout the stage• Compatible with glass and metal heating inserts

Requires one of the following controllers: • H401-T-CONTROLLER. Required controller when in com-

bination with H401-NIKON-TS2R-METAL or H601-NIKON-TS2R-GLASS

• H401-PENNY

TC-S

-SR,

TC-

S-SR

F TC

-S-S

R, T

C-S-

SRF

and

TS2-

S-SM

and

TS2-

S-SM

Nikon - Inverted

IVF catalog.indb 9 21/06/2018 13:19:52

Page 10: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

10

H601-PRRIOR H1177-GLASS-REECESSEDWarm ITO glass plate for Prior H117 stage

Features:• Compatible with Prior H117 stage• ITO (Iridium Tin Oxide) coated glass plate. Fits in the

opening of the XY stage and creates a surface recessed by 8.5 mm with respect to the rest of the XY stage rising the focal plane by 1.5 mm

• Dragontrail®: Chemically strengthened, scratch resistant, glass

• Aluminium frame for superior resistance and fl atness• Glass thickness 0.5 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-T-PENNY

K-Fr

ame

K-Fr

ame

H601-KK-FRAME-ME TALL/GLASSSWarm metal and ITO glass plate for Marzhauser (all models), Ludl (all

models), ASI (all models, including z-piezo), Prior H107 and H117

Features:• Compatible with the following XY stages: Marzhauser (all

models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107 and H117

• Fits in the opening of the XY stage and creates a fl at tem-perature controlled surface rising the focal plane by 7.5 mm (10 mm for Prior H117)

• Glass thickness 0.5 mm• Dragontrail®: Chemically strengthened, scratch resistant,

glass• Trimmed 24 mm diameter circular observation opening for

imaging • Compatible with oil immersion lenses• Metal and glass sides have independet temperture sensors

for independent temperature control of each sideRequires one of the following controllers:

• H401-T-CONTROLLER (one controller controls the glass the other controls the aluminium)

• H401-T-PENNY

/W tt ll dd ITOO l ll t f MM hhhh (( ll ddd l ))) L dl ((( ll

03.2

109.

7

159.7

99.6

67.2

K-Fr

ame

K-Fr

ame

H601-KK-FRAMEE -GLASSS-FLATWarm ITO glass plate for Marzhauser (all models), Ludl (all mod-

els), ASI (all models, including z-piezo), Prior H107 and H117Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107 and H117

• ITO (Iridium Tin Oxide) coated glass plate. Fits in the opening of the XY stage and creates a fl at temperature controlled surface rising the focal plane by 7.5 mm (10 mm for Prior H117)

• Dragontrail®: Chemically strengthened, scratch resistant, glass.

• Aluminium frame for superior resistance and fl atness• Glass thickness 0.5 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-T-PENNY

K-Fr

ame

K-Fr

ame

109.

7

3.20

159.7

133.6

99.6

02.8

109.

5

85

159.5

110

H601--K-FRAME-GGLASS-RECEESSEDWarm metal plate for Marzhauser (all models), Ludl (all models),

ASI (all models, including z-piezo), Prior H107Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107

• ITO (Iridium Tin Oxide) coated glass plate. Fits in the opening of the XY stage and creates a surface recessed by 6 mm with respect to the rest of the XY stage rising the focal plane by 1.5 mm

• Dragontrail®: Chemically strengthened, scratch resistant, glass

• Aluminium frame for superior resistance and fl atness• Glass thickness 0.5 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-T-PENNY

ll l ffff hh ll ddd l ddl llll d lll

02.8

109.

5

86.1

159.5

110.6

K-Fr

ame

K-Fr

ame

Nikon - K-Frame opening

IVF catalog.indb 10 21/06/2018 13:19:52

Page 11: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

11

H401-KK-FRAME-MMETAL-RECCESSEDWarm metal plate for Marzhauser (all models), Ludl (all models),

ASI (all models, including z-piezo), Prior H107Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107

• Fits in the opening of the XY stage and creates a temper-ature controlled surface recessed with resepct to the rest of the stage to maintain the original focal plane of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

04.5

109.

7

159.7

K-Fr

ame

K-Fr

ame

H401-KK-FRAMEE-METALL-FLATWarm metal plate for Marzhauser (all models), Ludl (all models),

ASI (all models, including z-piezo), Prior H107 and H117Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107 and H117

• Fits in the opening of the XY stage and creates a fl at tem-perature controlled surface at the same height of the rest of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

K-Fr

ame

K-Fr

ame

109.

7

30

159.7

H401-PRRIOR H117-METAL-RRECESSEDWarm metal plate

for Prior H117 stageFeatures:

• Compatible with Prior H117 stage• Fits in the opening of the XY stage and creates a temper-

ature controlled surface recessed with resepct to the rest of the stage to maintain the original focal plane of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

04.5

109.

7

159.7

K-Fr

ame

K-Fr

ame

H401--NIKON-NI-S-E-MMETALWarm metal plate for Nikon upright microscope Ecplipse with

NI-S-E-motorized stageFeatures:

• Fits in the insert of the NI-S-E-motorized stage and creates a fl at temperature controlled surface

• Features a trimmed 27 mm diameter circular observation opening for imaging

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

F

105.

9

20

4.5ø27

191.4

Ecpl

ipse

wit

h N

I-S-

EEc

plip

se w

ith

NI-

S-E

Nikon - K-Frame opening

IVF catalog.indb 11 21/06/2018 13:19:54

Page 12: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

12

HH401-UPP-METALLWarm metal plate for upright microscopes with glass slide traslators Features:

• Compatible with all the upright microscopes equippend with glass slide traslators

• Creates a heated surface under the glass slide transalator• Features a 40x15 mm rectangular opening for imaging

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

120.

502

120

UPR

IGH

TU

PRIG

HT

H401-NNIKON-SMZ-180--GLASSWarm ITO glass plate for Nikon stereo microscope SMZ

Features:• Compatible with the following stereo microscope series:

Nikon SMZ• ITO (Iridium Tin Oxide) coated glass plate. Fits in the cir-

cular 180 mm opening of the stereo microscope and cre-ates a fl at warm surface

• Aluminium frame for superior resistance and fl atness• Glass thickness 2 mm. Plate diameter 180mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

ø179

.8

80

08

128

SMZ

SMZ

H401--NIKON-TTI-S-ER-MMETALWarm metal plate for Nikon stages TI-S-E, TI-S-ER, TI2-S-SE-E

and TI2-S-SS-EFeatures:

• Compatible with the following XY stages: Nikon TI-S-E, TI-S-ER, TI2-S-SE-E and TI2-S-SS-E

• Fits in the opening of the XY stage and creates a temper-ature controlled surface recessed with respect to the rest of the stage to maintain the original focal plane of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

04.9

3

155

236

ø24

TI-S

-E,

TI-S

-ER,

TI2

-S-S

E-E

TI-S

-E,

TI-S

-ER,

TI2

-S-S

E-E

and

TI2-

S-SS

-Ean

d TI

2-S-

SS-E

H401-NIKON-TTI-SAM-MMETALWarm metal plate for Nikon TI-SAM, T-SAM, TI-SM attachable

mechanical stageFeatures:

• Compatible with the following XY stages: Nikon T/TI-SP+T/TI-SAM and TI-SM

• Fits in XY stage and creates a temperature controlled surface recessed with respect to the rest of the stage to maintain the original focal plane of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

04.9

1.65

127.

5

22

ø24

242TI-S

-E,

TI-S

-ER,

TI2

-S-S

E-E

TI-S

-E,

TI-S

-ER,

TI2

-S-S

E-E

and

TI2-

S-SS

-Ean

d TI

2-S-

SS-E

Nikon - other stages

IVF catalog.indb 12 21/06/2018 13:19:54

Page 13: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

13

238.

8

06

H401--NIKON-SSMZ25-GGLASSWarm ITO glass plate

for Nikon stereo microscope SMZFeatures:

• Compatible with the following stereo microscope’s stand: P2-PB, P2-DBC, P2-DBF, P-PS32, P-DSL32 and P-DSF32

• ITO (Iridium Tin Oxide) coated glass. Covers the entire stand and creates a fl at heated surface

• Aluminium frame for superior resistance and fl atness• Glass thickness 1 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

218.3

P2-P

B, P

2-DB

C, P

2-DB

F,

P2-P

B, P

2-DB

C, P

2-DB

F,

P-PS

32,

P-DS

L32

and

P-PS

32,

P-DS

L32

and

P-DS

F32

P-DS

F32

246.2

252.

7

06

H401--NIKON-SMZSL-GGLASSWarm ITO glass plate

for Nikon stereo microscope SMZ 1500/1000/800

Features:• Compatible with the following stereo microscope’s stand:

C-DSD, C-DSS, C-BD• ITO (Iridium Tin Oxide) coated glass plate. Covers the en-

tire stand and creates a fl at heated surface• Aluminium frame for superior resistance and fl atness• Glass thickness 1 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

C-DS

D, C

-DSS

, C-

BDC-

DSD,

C-D

SS,

C-BD

H401--NIKON--SMZSS-GGLASSWarm ITO glass plate for Nikon stereo microscope SMZ 1500/1000/800

Features:• Compatible with the following stereo microscope stand:

C-DS, C-PS• ITO (Iridium Tin Oxide) coated glass plate. Covers the en-

tire stand and creates a fl at warm surface• Aluminium frame for superior resistance and fl atness• Glass thickness 1 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

C-DS

, C-

PSC-

DS,

C-PS

130,

40

229

146,40200

0

106

Nikon - Stereo

IVF catalog.indb 13 21/06/2018 13:19:55

Page 14: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

14

H401-NIKON-SMZZSS-GLASS//METALLarge metal heating plate with central heating glass for Nikon

stereo microscope SMZ 1500/1000/800Features:

• Compatible with the following stereo microscope’s stand: C-DS, C-PS

• Large fl at heating surface covering the entire stereo mi-croscope stand

• Metal and glass surfaces can be independently heated to diff erent temperatures

• Glass thickness: 1 mmRequires one of the following controllers:

• H401-T-CONTROLLER uses both channels

/145

320

SMZ

1500

/100

0/80

0SM

Z 15

00/1

000/

800

130

8

550

H401-NIKON-SMZZSL-GLASS//METALLarge metal heating plate with central heating glass for Nikon

stereo microscope SMZ 1500/1000/800Features:

• Compatible with the following stereo microscope’s stand: C-DSD, C-DSS, C-BD

• Large fl at heating surface covering the entire stereo mi-croscope stand

• Metal and glass surfaces can be independently heated to diff erent temperatures

• Glass thickness: 1 mmRequires one of the following controllers:

• H401-T-CONTROLLER uses both channels

/145

320

SMZ

1500

/100

0/80

0SM

Z 15

00/1

000/

800

130

8

550

H401-NIKON-SMZZ25-GLASS//METALLarge metal heating plate with central heating glass Nikon for

stereo microscope SMZFeatures:

• Compatible with the following stereo microscope’s stand: P2-PB, P2-DBC, P2-DBF, P-PS32, P-DSL32 and P-DSF32

• Large fl at heating surface covering the entire stereo mi-croscope stand

• Metal and glass surfaces can be independently heated to diff erent temperatures

• Glass thickness: 1 mmRequires one of the following controllers:

• H401-T-CONTROLLER uses both channels

/145

320SM

ZSM

Z

130

8

550

H4401-GLAASS-TABLLEHeated Flat Glass Table

- (440x235 mm)Features:

• Can be positioned on any surface (Table Top, Cabinet work surface, etc) to create a temperature controlled area

• Temperature range: 27°C - 45°CRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

235

440

81 -

111

STER

EOST

EREO

Nikon - Stereo

IVF catalog.indb 14 21/06/2018 13:19:55

Page 15: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

15

H4401-T-PAAD-SMALLLHeated Flat Metal Plate

(174x234 mm)Features:

• Can be positioned on any surface (Table Top, Cabinet work surface, etc) to create a temperature controlled area

• Temperature range: 27°C - 45°CRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

H t dd FFl t M tt l PPl ttt(( ))

234

174

11.30

PAD

PAD

H4401-T-PAAD-LARGGEHeated Flat Metal Plate -

size A3 (420x300 mm)Features:

• Can be positioned on any surface (Table Top, Cabinet work surface, etc) to create a temperature controlled area

• Temperature range: 27°C - 45°CRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

420

300

11.30

PAD

PAD

H401-T-PADD-MEDIUUMHeated Flat Metal Plate - size A4 (297x210 mm)

Features:• Can be positioned on any surface (Table Top, Cabinet work

surface, etc) to create a temperature controlled area• Temperature range: 27°C - 45°C

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

297

210

11.30

PAD

PAD

Nikon - T-Pads

IVF catalog.indb 15 21/06/2018 13:19:55

Page 16: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

16

Warm metal plate for Olympus stages with circular openingFlat - 110 mm diameter

Features:• Fits in the circular opening of the XY stage and creates a

fl at temperature controlled surface, fl ush with the rest of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lenses• Plate diameter 108mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

ø109

.95

20

H401-OOLYMPUS--IX-SUSP-MMETAL

IX-S

USP

, G

X-SV

R, G

X-SF

R,

IX-S

USP

, G

X-SV

R, G

X-SF

R,

BX3-

SSU

, IX

2-SF

R, IX

2-SV

L-2

BX3-

SSU

, IX

2-SF

R, IX

2-SV

L-2

Warm ITO glass plate for Olympus stages with circular openingFlat - 110 mm diameter - Heated Glass and frame

Features:• ITO (Iridium Tin Oxide) coated glass plate. Fits in the cir-

cular opening of the XY stage and creates a fl at tempera-ture controlled surface, fl ush with the rest of the XY stage

• Dragontrail®: Chemically strengthened, scratch resistant, glass.

• Heated aluminum frame: Provides the highest tempera-ture uniformity by warming up both, the ITO coated glass and the surrounding aluminum circular case.

• Glass thickness 0.5 mm• Plate diameter 110mm

Requires one of the following controllers: • H401-T-CONTROLLER (one channel controls the glass and

the other channel controls the aluminum case) - suggested controller.

ø109

.95

0

2

64.6

H601-OLYYMPUS-IX-SSUSP-GLASSS/FRAME

IX-S

USP

, G

X-SV

R, G

X-SF

R, B

X3-S

SU,

IX-S

USP

, G

X-SV

R, G

X-SF

R, B

X3-S

SU,

IX2-

SFR,

IX2-

SVL-

2IX

2-SF

R, IX

2-SV

L-2

64.6

Warm ITO glass plate for Olympus stages with circular openingFlat - 110 mm diameter

Features:• ITO (Iridium Tin Oxide) coated glass plate. Fits in the cir-

cular opening of the XY stage and creates a fl at tempera-ture controlled surface, fl ush with the rest of the XY stage

• Dragontrail®: Chemically strengthened, scratch resistant, glass.

• Glass thickness 0.5 mm• Plate diameter 110mm

Requires one of the following controllers: • H401-T-CONTROLLER• H401-T-PENNY

ø109

.95

02

64.6

H601--OLYMPUSS-IX-SUSP-GGLASS

IX-S

USP

, G

X-SV

R, G

X-SF

R,

IX-S

USP

, G

X-SV

R, G

X-SF

R,

BX3-

SSU

, IX

2-SF

R, IX

2-SV

L-2

BX3-

SSU

, IX

2-SF

R, IX

2-SV

L-2

64.6

Heated Flat Plate for GX-SFR and IX2-SFR Olympus stages with

circular openingFeatures:

• The plate clumps on the stage and provides a heated fl at surface throughout the entire surface of the stage

• Does not cover the circular opening• Compatible with GX-SFR and IX2-SFR Olympus stages and

IX2-SFR Olympus• Rises the focal of the XY stage by: 2.5 mm• Flat surface throughout the stage• Compatible with H401-OLYMPUS-IX-SUSP-METAL and H601-

OLYMPUS-IX-SUPS-GLASSRequires one of the following controllers:

• H401-T-CONTROLLER. Required controller when in com-bination with H401-OLYMPUS-IX-SUSP-METAL or H601-OLYMPUS-IX-SUSP-GASS

• H401-PENNY

T/TI

-SR

and

TI-S

PT/

TI-S

R an

d TI

-SP

92.5

0

203

ø110

273

Olympus - Inverted and Upright

IVF catalog.indb 16 21/06/2018 13:19:56

Page 17: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

17

H601-PRRIOR H1177-GLASS-REECESSEDWarm ITO glass plate for Prior H117 stage

Features:• Compatible with Prior H117 stage• ITO (Iridium Tin Oxide) coated glass plate. Fits in the

opening of the XY stage and creates a surface recessed by 8.5 mm with respect to the rest of the XY stage rising the focal plane by 1.5 mm

• Dragontrail®: Chemically strengthened, scratch resistant, glass

• Aluminium frame for superior resistance and fl atness• Glass thickness 0.5 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-T-PENNY

K-Fr

ame

K-Fr

ame

H601-KK-FRAMEE-METAL/GLASSWarm metal and ITO glass plate for Marzhauser (all models), Ludl (all

models), ASI (all models, including z-piezo), Prior H107 and H117

Features:• Compatible with the following XY stages: Marzhauser (all

models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107 and H117

• Fits in the opening of the XY stage and creates a fl at tem-perature controlled surface rising the focal plane by 7.5 mm (10 mm for Prior H117)

• Glass thickness 0.5 mm• Dragontrail®: Chemically strengthened, scratch resistant,

glass• Trimmed 24 mm diameter circular observation opening for

imaging • Compatible with oil immersion lenses• Metal and glass sides have independet temperture sensors

for independent temperature control of each sideRequires one of the following controllers:

• H401-T-CONTROLLER (one controller controls the glass the other controls the aluminium)

• H401-T-PENNY

/W tt ll dd ITOO l ll t f MM hhhh (( ll ddd ll ))) L dl ((( ll

03.2

109.

7

159.7

99.6

67.2

K-Fr

ame

K-Fr

ame

H601-K-FRAME-GLASSS-FLATWarm ITO glass plate for Marzhauser (all models), Ludl (all mod-

els), ASI (all models, including z-piezo), Prior H107 and H117Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107 and H117

• ITO (Iridium Tin Oxide) coated glass plate. Fits in the opening of the XY stage and creates a fl at temperature controlled surface rising the focal plane by 7.5 mm (10 mm for Prior H117)

• Dragontrail®: Chemically strengthened, scratch resistant, glass.

• Aluminium frame for superior resistance and fl atness• Glass thickness 0.5 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-T-PENNY

K-Fr

ame

K-Fr

ame

109.

7

3.20

159.7

133.6

99.6

02.8

109.

5

85

159.5

110

H601-K-FRAME-GGLASS-RECEESSEDWarm metal plate for Marzhauser (all models), Ludl (all models),

ASI (all models, including z-piezo), Prior H107Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107

• ITO (Iridium Tin Oxide) coated glass plate. Fits in the opening of the XY stage and creates a surface recessed by 6 mm with respect to the rest of the XY stage rising the focal plane by 1.5 mm

• Dragontrail®: Chemically strengthened, scratch resistant, glass

• Aluminium frame for superior resistance and fl atness• Glass thickness 0.5 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-T-PENNY

ll l ffff hh ll ddd l ddl llll d lll

02.8

109.

5

86.1

159.5

110.6

K-Fr

ame

K-Fr

ame

Olympus - K-Frame opening

IVF catalog.indb 17 21/06/2018 13:19:56

Page 18: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

18

H401-KK-FRAME-MMETAL-RECCESSEDWarm metal plate for Marzhauser (all models), Ludl (all models),

ASI (all models, including z-piezo), Prior H107Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107

• Fits in the opening of the XY stage and creates a temper-ature controlled surface recessed with resepct to the rest of the stage to maintain the original focal plane of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

04.5

109.

7

159.7

K-Fr

ame

K-Fr

ame

H401-KK-FRAMEE-METALL-FLATWarm metal plate for Marzhauser (all models), Ludl (all models),

ASI (all models, including z-piezo), Prior H107 and H117Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107 and H117

• Fits in the opening of the XY stage and creates a fl at tem-perature controlled surface at the same height of the rest of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

K-Fr

ame

K-Fr

ame

109.

7

30

159.7

H401-PRRIOR H117-METAL-RRECESSEDWarm metal plate for Prior H117 stage

Features:• Compatible with Prior H117 stage• Fits in the opening of the XY stage and creates a temper-

ature controlled surface recessed with resepct to the rest of the stage to maintain the original focal plane of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

04.5

109.

7

159.7

K-Fr

ame

K-Fr

ame

HH401-UPP-METALLWarm metal plate for upright microscopes with glass slide traslators Features:

• Compatible with all the upright microscopes equipped with glass slide traslators

• Realizes a warm surface under the glass slide trasalator• Features a 40x15 mm rectangular opening for imaging

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

120.

502

120

UPR

IGH

TU

PRIG

HT

Olympus - K-Frame opening

IVF catalog.indb 18 21/06/2018 13:19:57

Page 19: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

19

Warm ITO glass plate for stereo microscope’s stand: SZX2-ILLT

Features:• Compatible with the following stereo microscope’s stand:

SZX2-ILLT• ITO (Iridium Tin Oxide) coated glass plate covers the en-

tire stand and creates a fl at warm surface• Aluminium frame for superior resistance and fl atness• Glass thickness 1 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

H401-OOLYMPUSS-SZX2B-GLASS

SZX2

-ILL

TSZ

X2-I

LLT

230

06

Warm ITO glass plate for stereo microscope’s stand: SZX2-ILLB, SZX2-ILLK, SZX2-ILLD

Features:• Compatible with the following stereo microscope’s stand:

SZX2-ILLB, SZX2-ILLK, SZX2-ILLD• ITO (Iridium Tin Oxide) coated glass plate covers the en-

tire stand and creates a fl at warm surface• Aluminium frame for superior resistance and fl atness• Glass thickness 1 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

224

06

H401-OOLYMPUSS-SZX2AA-GLASS

SZX2

-ILL

B, S

ZX2-

ILLK

, SZ

X2-I

LLB,

SZX

2-IL

LK,

SZX2

-ILL

DSZ

X2-I

LLD

234 225

H401-OLYYMPUS-SZXX2A-GLASS/METALLarge metal heating plate with central heating glass for Olympus

stereo microscope MVX and SZXFeatures:

• Compatible with the following stereo microscope’s stand: SZX2-ILLB, SZX2-ILLK, SZX2-ILLD

• Large fl at heating surface covering the entire stereo mi-croscope stand

• Metal and glass surfaces can be independently heated to diff erent temperatures

• Glass thickness: 1 mmRequires one of the following controllers:

• H401-T-CONTROLLER (uses both channels)

/145

320

SZX2

-ILL

B, S

ZX2-

ILLK

, SZ

X2-I

LLB,

SZX

2-IL

LK,

SZX2

-ILL

DSZ

X2-I

LLD

130

8

550

H401-OLYYMPUS-SZXX2B-GLASS/METALLarge metal heating plate with central heating glass for Olympus

stereo microscope MVX and SZXFeatures:

• Compatible with the following stereo microscope’s stand: SZX2-ILLT

• Large fl at heating surface covering the entire stereo mi-croscope stand

• Metal and glass surfaces can be independently heated to diff erent temperatures

• Glass thickness: 1 mmRequires one of the following controllers:

• H401-T-CONTROLLER (uses both channels)

/145

320

SZX2

-ILL

TSZ

X2-I

LLT

130

8

550

Olympus - Olympus Stereo

IVF catalog.indb 19 21/06/2018 13:19:58

Page 20: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

20

H4401-GLAASS-TABLLEHeated Flat Glass Table

- (440x235 mm)Features:

• Can be positioned on any surface (Table Top, Cabinet work surface, etc) to create a temperature controlled area

• Temperature range: 27°C - 45°CRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

235

440

81 -

111

STER

EOST

EREO

Olympus - Olympus Stereo

IVF catalog.indb 20 21/06/2018 13:19:58

Page 21: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

21

H401-T-PADD-MEDIUUMHeated Flat Metal Plate - size A4 (297x210 mm)

Features:• Can be positioned on any surface (Table Top, Cabinet work

surface, etc) to create a temperature controlled area• Temperature range: 27°C - 45°C

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

297

210

11.30

PAD

PAD

H4401-T-PAAD-LARGGEHeated Flat Metal Plate - size A3 (420x300 mm)

Features:• Can be positioned on any surface (Table Top, Cabinet work

surface, etc) to create a temperature controlled area• Temperature range: 27°C - 45°C

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

420

300

11.30

PAD

PAD

H4401-T-PAAD-SMALLLHeated Flat Metal Plate - (174x234 mm)

Features:• Can be positioned on any surface (Table Top, Cabinet work

surface, etc) to create a temperature controlled area• Temperature range: 27°C - 45°C

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

234

174

11.30

PAD

PAD

Olympus - T-Pads

IVF catalog.indb 21 21/06/2018 13:19:58

Page 22: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

22

H601-PRRIOR H1177-GLASS-REECESSEDWarm ITO glass plate for Prior H117 stage

Features:• Compatible with Prior H117 stage• ITO (Iridium Tin Oxide) coated glass plate. Fits in the

opening of the XY stage and creates a surface recessed by 8.5 mm with respect to the rest of the XY stage rising the focal plane by 1.5 mm

• Dragontrail®: Chemically strengthened, scratch resistant, glass

• Aluminium frame for superior resistance and fl atness• Glass thickness 0.5 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-T-PENNY

K-Fr

ame

K-Fr

ame

H601-KK-FRAMEE-METAL/GLASSWarm metal and ITO glass plate for Marzhauser (all models), Ludl (all

models), ASI (all models, including z-piezo), Prior H107 and H117

Features:• Compatible with the following XY stages: Marzhauser (all

models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107 and H117

• Fits in the opening of the XY stage and creates a fl at tem-perature controlled surface rising the focal plane by 7.5 mm (10 mm for Prior H117)

• Glass thickness 0.5 mm• Dragontrail®: Chemically strengthened, scratch resistant,

glass• Trimmed 24 mm diameter circular observation opening for

imaging • Compatible with oil immersion lenses• Metal and glass sides have independet temperture sensors

for independent temperature control of each sideRequires one of the following controllers:

• H401-T-CONTROLLER (one controller controls the glass the other controls the aluminium)

• H401-T-PENNY

/W tt ll dd ITOO l ll t ff MM hhhh (( ll ddd ll ))) L dl ((( ll

03.2

109.

7

159.7

99.6

67.2

K-Fr

ame

K-Fr

ame

H601-K-FRAMME-GLASSS-FLATWarm ITO glass plate for Marzhauser (all models), Ludl (all mod-

els), ASI (all models, including z-piezo), Prior H107 and H117Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107 and H117

• ITO (Iridium Tin Oxide) coated glass plate. Fits in the opening of the XY stage and creates a fl at temperature controlled surface rising the focal plane by 7.5 mm (10 mm for Prior H117)

• Dragontrail®: Chemically strengthened, scratch resistant, glass.

• Aluminium frame for superior resistance and fl atness• Glass thickness 0.5 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-T-PENNY

K-Fr

ame

K-Fr

ame

109.

7

3.20

159.7

133.6

99.6

02.8

109.

5

85

159.5

110

H601-K-FRAME-GGLASS-RECEESSEDWarm metal plate for Marzhauser (all models), Ludl (all models),

ASI (all models, including z-piezo), Prior H107Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107

• ITO (Iridium Tin Oxide) coated glass plate. Fits in the opening of the XY stage and creates a surface recessed by 6 mm with respect to the rest of the XY stage rising the focal plane by 1.5 mm

• Dragontrail®: Chemically strengthened, scratch resistant, glass

• Aluminium frame for superior resistance and fl atness• Glass thickness 0.5 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-T-PENNY

l l ffff hh ll dd l ddl llll d lll

02.8

109.

5

86.1

159.5

110.6

K-Fr

ame

K-Fr

ame

Leica - K-Frame opening

IVF catalog.indb 22 21/06/2018 13:19:58

Page 23: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

23

H401-KK-FRAME-MMETAL-RECCESSEDWarm metal plate for Marzhauser (all models), Ludl (all models),

ASI (all models, including z-piezo), Prior H107Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107

• Fits in the opening of the XY stage and creates a temper-ature controlled surface recessed with resepct to the rest of the stage to maintain the original focal plane of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

04.5

109.

7

159.7

K-Fr

ame

K-Fr

ame

H401-KK-FRAMEE-METALL-FLATWarm metal plate for Marzhauser (all models), Ludl (all models),

ASI (all models, including z-piezo), Prior H107 and H117Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107 and H117

• Fits in the opening of the XY stage and creates a fl at tem-perature controlled surface at the same height of the rest of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

K-Fr

ame

K-Fr

ame

109.

7

30

159.7

H401-PRRIOR H117-METAL-RRECESSEDWarm metal plate

for Prior H117 stageFeatures:

• Compatible with Prior H117 stage• Fits in the opening of the XY stage and creates a temper-

ature controlled surface recessed with resepct to the rest of the stage to maintain the original focal plane of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

04.5

109.

7

159.7

K-Fr

ame

K-Fr

ame

Warm metal plate for Leica stages with circular openingFlat - 88 mm diameter

Features:• Fits in the circular opening of the XY stage and creates a

fl at temperature controlled surface, fl ush with the rest of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lenses• Plate diameter 88 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

ø86,

85

H401-LEICA--R88-METTAL

2,10

Leica - K- Frame opening and R88

IVF catalog.indb 23 21/06/2018 13:19:59

Page 24: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

24

H4401-GLAASS-TABLLEHeated Flat Glass Table

- (440x235 mm)Features:

• Can be positioned on any surface (Table Top, Cabinet work surface, etc) to create a temperature controlled area

• Temperature range: 27°C - 45°CRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

235

440

81 -

111

STER

EOST

EREO

Leica - for Stereo

IVF catalog.indb 24 21/06/2018 13:20:00

Page 25: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

25

H401-T-PADD-MEDIUUMHeated Flat Metal Plate - size A4 (297x210 mm)

Features:• Can be positioned on any surface (Table Top, Cabinet work

surface, etc) to create a temperature controlled area• Temperature range: 27°C - 45°C

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

297

210

11.30

PAD

PAD

H4401-T-PAAD-LARGGEHeated Flat Metal Plate - size A3 (420x300 mm)

Features:• Can be positioned on any surface (Table Top, Cabinet work

surface, etc) to create a temperature controlled area• Temperature range: 27°C - 45°C

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

420

300

11.30

PAD

PAD

H4401-T-PAAD-SMALLLHeated Flat Metal Plate - (174x234 mm)

Features:• Can be positioned on any surface (Table Top, Cabinet work

surface, etc) to create a temperature controlled area• Temperature range: 27°C - 45°C

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

234

174

11.30

PAD

PAD

Leica - T-Pads

IVF catalog.indb 25 21/06/2018 13:20:00

Page 26: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

26

H601-PRRIOR H1177-GLASS-REECESSEDWarm ITO glass plate for Prior H117 stage

Features:• Compatible with Prior H117 stage• ITO (Iridium Tin Oxide) coated glass plate. Fits in the

opening of the XY stage and creates a surface recessed by 8.5 mm with respect to the rest of the XY stage rising the focal plane by 1.5 mm

• Dragontrail®: Chemically strengthened, scratch resistant, glass

• Aluminium frame for superior resistance and fl atness• Glass thickness 0.5 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-T-PENNY

K-Fr

ame

K-Fr

ame

H601-KK-FRAMEE-METAL/GLASSSWarm metal and ITO glass plate for Marzhauser (all models), Ludl (all

models), ASI (all models, including z-piezo), Prior H107 and H117

Features:• Compatible with the following XY stages: Marzhauser (all

models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107 and H117

• Fits in the opening of the XY stage and creates a fl at tem-perature controlled surface rising the focal plane by 7.5 mm (10 mm for Prior H117)

• Glass thickness 0.5 mm• Dragontrail®: Chemically strengthened, scratch resistant,

glass• Trimmed 24 mm diameter circular observation opening for

imaging • Compatible with oil immersion lenses• Metal and glass sides have independet temperture sensors

for independent temperature control of each sideRequires one of the following controllers:

• H401-T-CONTROLLER (one controller controls the glass the other controls the aluminium)

• H401-T-PENNY

/W tt ll dd ITOO l ll t f MM hhhh (( ll ddd l ))) L dl ((( ll

03.2

109.

7

159.7

99.6

67.2

K-Fr

ame

K-Fr

ame

H601-K-FRAMME-GLASSS-FLATWarm ITO glass plate for Marzhauser (all models), Ludl (all mod-

els), ASI (all models, including z-piezo), Prior H107 and H117Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107 and H117

• ITO (Iridium Tin Oxide) coated glass plate. Fits in the opening of the XY stage and creates a fl at temperature controlled surface rising the focal plane by 7.5 mm (10 mm for Prior H117)

• Dragontrail®: Chemically strengthened, scratch resistant, glass.

• Aluminium frame for superior resistance and fl atness• Glass thickness 0.5 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-T-PENNY

K-Fr

ame

K-Fr

ame

109.

7

3.20

159.7

133.6

99.6

02.8

109.

5

85

159.5

110

H601--K-FRAME-GGLASS-RECEESSEDWarm metal plate for Marzhauser (all models), Ludl (all models),

ASI (all models, including z-piezo), Prior H107Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107

• ITO (Iridium Tin Oxide) coated glass plate. Fits in the opening of the XY stage and creates a surface recessed by 6 mm with respect to the rest of the XY stage rising the focal plane by 1.5 mm

• Dragontrail®: Chemically strengthened, scratch resistant, glass

• Aluminium frame for superior resistance and fl atness• Glass thickness 0.5 mm

Requires one of the following controllers: • H401-T-CONTROLLER • H401-T-PENNY

ll l ffff hh ll ddd l ddl llll d lll

02.8

109.

5

86.1

159.5

110.6

K-Fr

ame

K-Fr

ame

Zeiss - K-Frame opening

IVF catalog.indb 26 21/06/2018 13:20:00

Page 27: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

27

H401-KK-FRAME-MMETAL-RECCESSEDWarm metal plate for Marzhauser (all models), Ludl (all models),

ASI (all models, including z-piezo), Prior H107Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107

• Fits in the opening of the XY stage and creates a temper-ature controlled surface recessed with resepct to the rest of the stage to maintain the original focal plane of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

04.5

109.

7

159.7

K-Fr

ame

K-Fr

ame

H401-KK-FRAMEE-METALL-FLATWarm metal plate for Marzhauser (all models), Ludl (all models),

ASI (all models, including z-piezo), Prior H107 and H117Features:

• Compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-pi-ezo), Prior H107 and H117

• Fits in the opening of the XY stage and creates a fl at tem-perature controlled surface at the same height of the rest of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

K-Fr

ame

K-Fr

ame

109.

7

30

159.7

H401-PRRIOR H117-METAL-RRECESSEDWarm metal plate

for Prior H117 stageFeatures:

• Compatible with Prior H117 stage• Fits in the opening of the XY stage and creates a temper-

ature controlled surface recessed with resepct to the rest of the stage to maintain the original focal plane of the XY stage

• Trimmed 24 mm diameter circular observation opening for imaging

• Compatible with oil immersion lensesRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

04.5

109.

7

159.7

K-Fr

ame

K-Fr

ame

HH401-UPP-METALLWarm metal plate for upright microscopes with glass slide traslators Features:

• Compatible with all the upright microscopes equippend with glass slide traslators

• Creates a heated surface under the glass slide transalator• Features a 40x15 mm rectangular opening for imaging

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

120.

5

02

120

UPR

IGH

TU

PRIG

HT

Zeiss - K-Frame opening

IVF catalog.indb 27 21/06/2018 13:20:01

Page 28: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

28

H4401-GLAASS-TABLLEHeated Flat Glass Table

- (440x235 mm)Features:

• Can be positioned on any surface (Table Top, Cabinet work surface, etc) to create a temperature controlled area

• Temperature range: 27°C - 45°CRequires one of the following controllers:

• H401-T-CONTROLLER • H401-PENNY

235

440

81 -

111

STER

EOST

EREO

Zeiss - STEREO

IVF catalog.indb 28 21/06/2018 13:20:02

Page 29: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

29

H401-T-PADD-MEDIUUMHeated Flat Metal Plate - size A4 (297x210 mm)

Features:• Can be positioned on any surface (Table Top, Cabinet work

surface, etc) to create a temperature controlled area• Temperature range: 27°C - 45°C

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

297

210

11.30

PAD

PAD

H4401-T-PAAD-LARGGEHeated Flat Metal Plate - size A3 (420x300 mm)

Features:• Can be positioned on any surface (Table Top, Cabinet work

surface, etc) to create a temperature controlled area• Temperature range: 27°C - 45°C

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

420

300

11.30

PAD

PAD

H4401-T-PAAD-SMALLLHeated Flat Metal Plate - (174x234 mm)

Features:• Can be positioned on any surface (Table Top, Cabinet work

surface, etc) to create a temperature controlled area• Temperature range: 27°C - 45°C

Requires one of the following controllers: • H401-T-CONTROLLER • H401-PENNY

234

174

11.30

PAD

PAD

Zeiss - T-Pads

IVF catalog.indb 29 21/06/2018 13:20:02

Page 30: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

30

Leo Portable Meter

For incubator featuring gas sampling port with spontaneous outlet

For incubator featuring gas sampling port without a spontaneous outlet

Gas fl ows into LEO through a dedicated diff usion inlet.Suction pump is not activated.

LEO activates its suction pump to sample gas from the incubator.LEO releases the sampled gas through its output port. Gas can be VOC fi ltered and reinjected into the incubator.

CO2 - O2 SSampling

Diff usion Mode Pump Mode

LEO is a battery operated, handheld analyzer designed to meas-ure CO2, O2, Temperature, VOC, Relative Humidity and pH.

Includes CO2 and O2 sensors.

Optional modules: Temperature, Humidity, VOC and pH

LEO• User-friendly touch screen interface• Compatible with any incubator on the market • Diff usion or Pump gas sampling modes• Pump suction rate 100 ml/min• Sampling tube and de-humidifi cation kit included• Long term logging • Micro USB for data download• Calibration:

a) Removable sensors can be shipped to certifi ed laboratories to be calibrated. Calibration is stored in sensor on-board mem-ory. Leo reads calibration upon sensor installation b) In situ sensor calibration via LEO calibration

CO2-O2 module can be easily extracted from LEO and sent out for calibration.

The module stores calibration data in its own memory, that Leo reads when the module is put in place.

CO2-O2 Module - Always included

Type Range Accuracy

CO2

Non Dispersive InfraRed (NDIR) dual wave length detector with pressure and temperature com-

pensation

0-20%±(1.0% of full scale +2% scaling) at 6% = ±0.32%

O2

Fluorescence based optical sensor

0-25%±(1.0% of full scale) at 6%

= ±0.25%

IVF catalog.indb 30 21/06/2018 13:20:02

Page 31: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

31

Leo Portable Meter

Each sensor module stores calibration data in its own local mem-ory, that LEO reads upon connection.

Leo features two external temperature modules, which can oper-ate at the same time:

• T1 is a small, fl exible immersible thermocouple, ideal for measurements in liquids, such as the culture media in the dish.

• T2 is a thermistor, ideal for measurements of incubator tem-perature, accessed through the sampling port.

T Moddules

Type Range Accuracy

T1K-type Thermocouple.

PFA-insulated; Length: 2 m; OD: 0.13 mm

20-45°C ± 0.1 °C

T2PT1000

Probe length: 150 mm; OD: 1.5 mm; Cable length: 1 m

20-45°C ± 0.1 °C

T1

T2

IVF catalog.indb 31 21/06/2018 13:20:04

Page 32: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

32

Leo Portable Meter

LEO T S

Type

LEO Handheld, touch screen, battery operated analyzer. Includes CO2-O2 module, sampling tube and de-humidifi cation kit.

CO2-O2 module(included in Leo)

CO2: Non Dispersive InfraRed (NDIR) dual wave length detector LIFETIME : 5 YEARS O2: Fluorescence based optical sensor LIFETIME : 5 YEARS

T1 module K-type Thermocouple; OD: 0.13 mm

T2 module PT1000 Thermoresistance - Probe length: 150 mm; OD: 1.5 mm

CO2/O2 calibration kit6 mm O tygon tube with a calibrated orifi ce deliveing a fl ow of 100 ml/min to Leo when connected to a gas source at 1 barg (14.7 psig)

Hard Case(included in Leo) Hard travel case for Leo and its accessories

IVF catalog.indb 32 21/06/2018 13:20:05

Page 33: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

33

NOTES

IVF catalog.indb 33 21/06/2018 13:20:05

Page 34: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

34

Tri-Gas Mixer

TRI-GAS MIXXER 1.5LPM AAND 15LPM

GAS INPUTT REQUIREMMENT

The Tri-Gas Mixer delivers gas mixture of the desired CO2 and O2 concentration with output pressure in the range of 0-2 bar (0-30 psi). Delivery pressure is easily regulated by adjusting the knob of the embedded pressure gauge.

The device is equipped with a mixing tank to ensure the highest composition stability even when the required output fl ow is variable.

Models available with maximum output fl ow rate of 1.5 L/min and 15 L/min. The actual fl ow rate delivered automatically adjusts to match the requirements of the equipment connected.

The Tri-Gas Mixer is compatible with any mini incubator available on the market.

The Tri-Gas Mixer must be connected to pressurized sources of CO2 - N2- Air. Minimum input pressure is related to the desired delivery pressure according to Pinput= Poutput+ 1.3 bar (20 psi).

Okolab air compressors are available to provide pressurized background air.

SECURIITY FEAATURES

To enable the safety routines the Tri-Gas Mixer must also be connected to a pre-mixed back-up cylinder containing gas of the desidered concentration.

The mixer will automatically switch to the backup pre-mixed cylinder if any of the following condition occurs:

• pressure in the mixing tank becomes too low (for instance due to gas requirement exceeding maximum mixer capacity).

• pressure of any of the input gasses becomes too low.

• target gas concentration cannot be achieved.

The Tri-Gas Mixer features advanced safety routines to ensure that the incubators always receive the proper gas.

IVF catalog.indb 34 21/06/2018 13:20:05

Page 35: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

35

Tri-Gas Mixer

The Tri-Gas Mixer is available in two models, with maximum output fl ow rate capacity of 1.5 and 15L/min. Besides internal components, the two models diff er by the size of the mixing tank (specs in the back of this brochure).

T -G M 1.5LPM T -G M 15LPM

CO2-O2 S CThe CO2-O2 sensor module stores the calibration in local memory. The CO2-O2 sensor module can be conveniently calibrated on-site with intuitive routines or can be easily extracted from the Tri-Gas Mixer, replaced with a spare CO2-O2 sensor module and sent out for calibration. In both cases, there is no need to disconnect or turn off the Tri-gas Mixer nor to discontinue the gas supply to the incubators.

IVF catalog.indb 35 21/06/2018 13:20:10

Page 36: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

36

Tri-Gas Mixer

FEATURES TRI-GAS MIXER 1.5 LPM TRI-GAS MIXER 15 LPM

Output maximum fl ow rate 1.5 L/min 15 L/min

Output pressure 0-2 bar (0-30 psi) regulated with embedded pressure gauge

CO2 range 0-10%

CO2 accuracy ±0.1%

CO2 sensor Non Dispersive InfraRed (NDIR) dual wave length detector. Expected lifetime 10 years

O2 range 0-10%

O2 accuracy ±0.1%

O2 sensor Optical Oxygen Sensor. Expected lifetime 5 years

Air compressor AIR-COMPRESSOR-1.5L AIR-COMPRESSOR-CP3-15L

Mixer dimensions 270x140x325 mm

Mixing tank size 4L 40L

Input gas CO2, N2, air @ 1.3 bar (20 psi) above output pressure

Input gas connectors stainless steel ¼” tube fi ttings

Switch over to backup cylinder

T - M T S

IVF catalog.indb 36 21/06/2018 13:20:11

Page 37: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

37

NOTES

IVF catalog.indb 37 21/06/2018 13:20:12

Page 38: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

36

Gas Controllers for Cell Cultures Incubator

CO2-O2 CONTTROLLERS FOOR CELL INCUBATOR

O2 CONTROLLER is compatible with any existing Cell Culture CO2 incubator equipped with an access port to add O2 control in the entire incubator.

CO2 -O2 CONTROLLER adds both O2 and CO2 control to the entire incubator or to a smaller semi sealed volume inside it.

To avoid contamination, the system introduces only 2 small tubes through the access port of the incubator.

The inlet tube infuses pure N2 and CO2 into the incubator. The suction pump periodically withdraws a small amount of gas from the incubator to measure O2 and CO2 concentration to provide feedback.

A DRYER attaches magnetically to the side of the incubator and reduces the humidity content of the gas before performing the measurement.

*Applies only to CO2-O2 CONTROLLER

• Adds 100% CO2 and 100% N2 to the volume in which gas control is desired.

• CO2 range: 0-20%

• O2 range: 1-20%

• Accuracy: ± 0.1%

• Set Point Resolution: 0.1%; Repeatability: better than 0.1

• CO2 sensor: 10 year-life Non Dispersive InfraRed (NDIR) dual wave length detector

• O2 sensor: optical sensor - 5 years lifetime

• Sensor calibration against external meter or calibration gas

• Suitable for semi sealed volumes ranging from 10 to 200 liters

• Build in suction pump allows to suck out the gas to perform the concentration measurements

• High effi ciency dryer to dehumidify the gas for concentration measurement (needed only if gas in controlled vol-ume is humid)

• Alarm Buzzer and External Alarm Connector

• RS232 and Mini USB ports for data logging through Okolab DATA LOG software or any third party software via DLL

• DRYER: membrane based dryer that attaches magnetically to the outer side of the incubator

IVF catalog.indb 36 21/06/2018 13:20:12

Page 39: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

37

Gas Controllers for Cell Cultures Incubator

PRODUCT CODE CO2 RANGE O2 RANGE

O2 CONTROLLER - 0-21%

CO2 CONTROLLER 0-20% -

CO2 - O2 CONTROLLER 0-20% 0-21%

O2 C

Adds hypoxia control to any CO2 Incubator or semi-sealed volume

CO2-O2 C

Adds hypoxia and CO2 control to any Incubator or semi-sealed volume

CO2 C

Adds CO2 control to any Incubator or semi-sealed volume

IVF catalog.indb 37 21/06/2018 13:20:13

Page 40: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

ICO2 CONTROLLER ...........................................................................................................................37CO2-O2 CONTROLLER .......................................................................................................................37H401-GLASS-TABLE ............................................................................................................14, 20, 24, 28H401-K-FRAME-METAL-FLAT..................................................................................................11, 18, 23, 27H401-K-FRAME-METAL-RECESSED ...........................................................................................11, 18, 23, 27H401-NIKON-NI-S-E-METAL .................................................................................................................11H401-NIKON-SMZ25-GLASS .................................................................................................................13H401-NIKON-SMZ25-GLASS/METAL ........................................................................................................14H401-NIKON-SMZ-180 .......................................................................................................................12H401-NIKON-SMZSL-GLASS .................................................................................................................13H401-NIKON-SMZSL-GLASS/METAL ........................................................................................................14H401-NIKON-SMZSS-GLASS .................................................................................................................13H401-NIKON-SMZSS-GLASS/METAL ........................................................................................................14H401-NIKON-TI-SAM-METAL ................................................................................................................12H401-NIKON-TI-S-ER-METAL ................................................................................................................12H401-NIKON-TI-SR-METAL ................................................................................................................... 8H401-NIKON-TI-SR-T-PAD .................................................................................................................... 8H401-NIKON-TS2R-METAL-FLAT ............................................................................................................. 9H401-NIKON-TS2R-T-PAD .................................................................................................................... 9H401-OLYMPUS-IX-SUSP-METAL ....................................................................................................... 16, 23H401-OLYMPUS-SZX2A-GLASS ..............................................................................................................19H401-OLYMPUS-SZX2A-GLASS/METAL .....................................................................................................19H401-OLYMPUS-SZX2B-GLASS ..............................................................................................................19H401-OLYMPUS-SZX2B-GLASS/METAL .....................................................................................................19H401-PRIOR H117-GLASS-RECESSED ................................................................................................. 17, 26H401-PRIOR H117-METAL-RECESSED ........................................................................................11, 18, 23, 27H401-T-CONTROLLER ..................................................................................................................... 4, 6H401-T-PAD-LARGE ............................................................................................................15, 21, 25, 29H401-T-PAD-MEDIUM ..........................................................................................................15, 21, 25, 29H401-T-PAD-SMALL ............................................................................................................15, 21, 25, 29H401-T-PENNY ................................................................................................................................ 6H401-UP-METAL .................................................................................................................... 12, 18, 27H601-K-FRAME -GLASS-FLAT ...............................................................................................................10H601-K-FRAME-GLASS-FLAT ..................................................................................................10, 17, 22, 26H601-K-FRAME-GLASS-RECESSED ............................................................................................10, 17, 22, 26H601-K-FRAME-ME TAL/GLASS .............................................................................................................10H601-K-FRAME-METAL/GLASS ...............................................................................................10, 17, 22, 26H601-NIKON-TI-SR-GLASS ................................................................................................................... 8H601-NIKON-TS2R-GLASS ................................................................................................................... 9H601-NIKON-TS2R-GLASS-FLAT ............................................................................................................. 9H601-NIKON-TS2R-METAL/GLASS .......................................................................................................... 9H601-OLYMPUS-IX-SUSP-GLASS ............................................................................................................16H601-PRIOR H117-GLASS-RECESSED ................................................................................................. 10, 22LEO ............................................................................................................................................30O2 CONTROLLER ............................................................................................................................37TRI-GAS MIXER ...............................................................................................................................34

IVF catalog.indb 38 21/06/2018 13:20:13

Page 41: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

NOTES

IVF catalog.indb 39 21/06/2018 13:20:13

Page 42: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

NOTES

IVF catalog.indb 40 21/06/2018 13:20:13

Page 43: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

NOTES

IVF catalog.indb 41 21/06/2018 13:20:13

Page 44: OKOLAB · 2019. 4. 9. · • Trimmed 24mm diameter circular observation opening for imaging in the metal side of the plate • Compatible with oil immersion lenses • Metal and

www.oko-lab.com