Page 1 company presentation 2012 23/11/2012 One Day National Workshop on Common Effluent Treatment Plants CII - Sohrabji Godrej Green Business Centre, Hyderabad Monitoring 23 November 2012 Energy Efficient Turbo Blowers for Aeration Kiron C. Pande - Godrej & Boyce Mfg. Co. Ltd.

Upload: allie

Post on 24-Feb-2016

33 views

Category:

Documents


0 download

DESCRIPTION

One Day National Workshop on Common Effluent Treatment Plants CII - Sohrabji Godrej Green Business Centre, Hyderabad. Energy Efficient Turbo Blowers for Aeration Kiron C. Pande - Godrej & Boyce Mfg. Co. Ltd. Technical Session II: Treatment Technologies & Monitoring. 23 November 2012 . - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: One Day National Workshop on Common Effluent Treatment Plants

Page 1company presentation 201223/11/2012

One Day National Workshop onCommon Effluent Treatment Plants

CII - Sohrabji Godrej Green Business Centre, Hyderabad

Technical Session II: Treatment Technologies & Monitoring

23 November 2012

Energy Efficient Turbo Blowers for Aeration

Kiron C. Pande - Godrej & Boyce Mfg. Co. Ltd.

Page 2: One Day National Workshop on Common Effluent Treatment Plants

Page 2

43%

33%24%

Energy CostAerationPretreatmentDewatering & Sludge treatment

Effluent Water Treatment

Page 3: One Day National Workshop on Common Effluent Treatment Plants

Page 3

Positive Displacement type, Twin Lobe Air Blower

Page 4: One Day National Workshop on Common Effluent Treatment Plants

Page 4

Volumetric Turbo

Multi stageTurbo blower

Low speed Turbo

- η Increase over 10%- No Volumetric pulsation

Efficiency Increased over 40%

Blower

Direct driven High Speed

- η Increase over 10%

- η Increase over 20%

- Increase stability

Increasing Energy Efficiency

High Speed Turbo

High Gear Ratio

Multi stageTurbo blower

Rootsblower

PD

Page 5: One Day National Workshop on Common Effluent Treatment Plants

Page 5

Turbo Blowers

Page 6: One Day National Workshop on Common Effluent Treatment Plants

Page 6

Energy Efficiency

certified by:

Korea Energy

Management

Corporation

Page 7: One Day National Workshop on Common Effluent Treatment Plants

Page 7

User selectable Control Modes with KTurbo

• Constant Flow• Constant Pressure• Constant Power• D.O. Control

Page 8: One Day National Workshop on Common Effluent Treatment Plants

Page 8

Constant Pressure Mode

Constant Flow Mode

Constant Current Mode

User Selectable Control Modes

Page 9: One Day National Workshop on Common Effluent Treatment Plants

Page 9

Core Components & Salient Features• Permanent Magnet Motor: a) Power required only to rotate

& not for magnetizing of rotor; b) Can be started & stopped any number of times; c) High Efficiency even at part load

• No Gear Box: No transmission loss due to direct drive & no lubrication required.

• Variable Speed Drive for achieving high speed, smooth starts (reduced starting current) & energy efficient capacity control as part of the Blower package.

• Air Foil bearing for high speed operation (used in Jet engines)

• Oil Free air• Low Noise: 80 dB against 100 dB of PD blowers• Entire range is air-cooled & no need of water for cooling.

Page 10: One Day National Workshop on Common Effluent Treatment Plants

Page 10

Comparison with PD Blowers

Parameter PD Blower

KTurbo Blower

Aero Efficiency 55% 77%Drive Efficiency (Motor+Coupling+Invertor)

82% 92%

Total Efficiency at 100% Load 45% 70%Total Efficiency at 50% Load 22.5% 67%Starting Current compared to Rated Current

250% Below 5%

Maintenance Overhaul Air FiltersLife 5 Years Semi-

permanentFoot Print Large SmallerNoise Level 95-110 dB Below 80

dB

Page 11: One Day National Workshop on Common Effluent Treatment Plants

Page 11

PD Blowers Performance

Page 12: One Day National Workshop on Common Effluent Treatment Plants

Page 12

Typical model at 1800 RPM; Average total efficiency is 45%

PD Blowers Performance

Page 13: One Day National Workshop on Common Effluent Treatment Plants

Page 13

PD Blowers Performance

Page 14: One Day National Workshop on Common Effluent Treatment Plants

Page 14

Single Stage Turbo Blowers Performance

Page 15: One Day National Workshop on Common Effluent Treatment Plants

Page 15

High Speed Turbo & PD Blower Performance

Page 16: One Day National Workshop on Common Effluent Treatment Plants

Page 16

High Speed Turbo & PD Blower Performance

Page 17: One Day National Workshop on Common Effluent Treatment Plants

Page 17

(Benefits with KTurbo )1) Discharge Temperature : Less

than 20° C than Roots type. => Change Aerated water

temperature: less than 3 ℃ than with Roots blower used earlier

2) Capacity control : Operating 1㎥ /min

=> Protect for excessive aeration 3) Oil-less System => 100% oil-less air 4) Reduce energy consumption:

more 40% (Before using roots blower)

5) Noise level : 82dB @ 1m (as against earlier 105dB with Roots blower)

Aeration: Coca Cola (Korea)

Page 18: One Day National Workshop on Common Effluent Treatment Plants

Page 18

SunRiver: North America installation

• Before : 2 Units of 100hp Multi Stage• After: 1 Unit of TB100-0.8 (70% Operation)

Page 19: One Day National Workshop on Common Effluent Treatment Plants

Page 19

Control Configuration for DO (Dissolved Oxygen)

Intrinsic Feedback control

DO data( 4 ~ 20mA)

Flow Control

※ DO Sensor (Endress+Hauser Co.)

Input: 0.015 ~ 60 ppm Output: 4 ~20mA

HMI Display

Page 20: One Day National Workshop on Common Effluent Treatment Plants

Page 20

Schematic of KTurbo installation in WWTP plant

Page 21: One Day National Workshop on Common Effluent Treatment Plants

Page 21

Picture of KTurbo installation in WWTP plant

Page 22: One Day National Workshop on Common Effluent Treatment Plants

Page 22

Picture of KTurbo installation in WWTP plant

Page 23: One Day National Workshop on Common Effluent Treatment Plants

Page 23

KTurbo blowers supplying air to WWTP plant

Page 24: One Day National Workshop on Common Effluent Treatment Plants

Page 24

Inverter

Power In Control

s

Intake Silencer

BOV Silencer

Construction of Single & Twin Turbo Blowers / Comp

Page 25: One Day National Workshop on Common Effluent Treatment Plants

Page 25

PM Motor&

Impellers

2 Pole permanent magnet (SmCo) with high strength retaining ring

High performance electric core

H Class Insulation winding

Radial airfoil bearing

Radial airfoil bearingThrust disk &

Thrust bearing

Stainless steel casted Impeller

Scroll

Intake

Discharge

Page 26: One Day National Workshop on Common Effluent Treatment Plants

Page 26

Core Technologies(1) Air foil bearings

• Self-acting hydrodynamic float on air• Bump foil acting as a spring• The first generation

– Axially & circumferentially uniform elastic support elements• The second generation

– Variable axial OR circumferential compliance characteristics• The third generation

– Foil support in axial, circumferential AND radial direction

Page 27: One Day National Workshop on Common Effluent Treatment Plants

Page 27

History of Foil Bearings

Simple Bump

Reversed Multi-Layer

Multi-Leaf

High Capacity, High Speed, High Damping, High Temperature

Multi-Pad Bump

Third Generation Bump(KTurbo)

• Radial variation• Circumferential

variation• Axial split/variation

• MiTi have made major research• KTurbo has > 1000 units experiences• KTurbo has TC series

Teflon-S

MoS2

High Temp Solid Lubricant- PS304 ; NASA- KOROLON1350F ; MiTi

Page 28: One Day National Workshop on Common Effluent Treatment Plants

Page 28

(2) High-speed & high-power PM motor/driver• PM motors

– High-speed & high-power (50 hp ~ 600 hp / 20,000 rpm ~ 70,000 rpm)

– High efficiency (> 95%)• Sensor-less Inverters

– Cost-effective– High efficiency (> 97%)

Core Technologies

Page 29: One Day National Workshop on Common Effluent Treatment Plants

Page 29

Why PM motor ?

No magnetizing power is necessary Lower heat generation means less cooling loss. Smaller rotor means less friction loss No slip means high efficiency even at part load

condition.

Page 30: One Day National Workshop on Common Effluent Treatment Plants

Page 30

Efficiency of PM motor & Induction Motor

Page 31: One Day National Workshop on Common Effluent Treatment Plants

Page 31

1. Stainless Steel• SUS630, 17-4PH

2. Optimum Specific Speed• Maximum efficiency

3. Optimum back sweep angle• Maximum efficiency• High Rise to surge• Wide operating range

4. Splitter Blade• Larger flow capacity• Higher efficiency

5. Leaning• Higher structural

strength

(3) Features of KTurbo ImpellerCore Technologies

Page 32: One Day National Workshop on Common Effluent Treatment Plants

Page 32

Built-in Flow Meter

Bell mouth is more accurate than Orifice, because it needs only one sensor.

]99.0min,/m Pa,sec,K,[m, 11

260 3

1/1

d

kk

k

d CPpP

kkTR

PpPAcQ

Page 33: One Day National Workshop on Common Effluent Treatment Plants

Page 33

Discharge Duct

Blow-off ValveSilencerBlower core

Inverter

Discharge pressure : PDischarge Temp : T2Suction Flow rate dP :

dP3Suction Temp : T1Filter Pressure Drop : dP1

Air Flow measuring

Air inAir out

Impeller

Inlet Reducer

T1 dP3 [Differential pressure]

+

< Air Flow calculation, Q >

Q ≈ Q (T1, Po , dP3)

Measurement System

Page 34: One Day National Workshop on Common Effluent Treatment Plants

Page 34

HMI with touch screen

Page 35: One Day National Workshop on Common Effluent Treatment Plants

Page 35

HMI: Main Screen

Page 36: One Day National Workshop on Common Effluent Treatment Plants

Page 36

HMI: Operating Curves display

Page 37: One Day National Workshop on Common Effluent Treatment Plants

Page 37

CF memory is applied• Data logging every 1 sec, 1 min, 1hour• All event recording

HMI: Data Logged every second

Page 38: One Day National Workshop on Common Effluent Treatment Plants

Page 38

CF memory is applied• Data logging every 1 sec, 1 min, 1hour• All event recording

HMI: On-line trend display

Page 39: One Day National Workshop on Common Effluent Treatment Plants

Page 39

CCR(Central Control Room) SCADA or DCS or PLC

MCP1

TB #1 TB #2 TB #3 TB #4

MCP2

TB #1 TB #2 TB #3 TB #4

Multi-Group Control

Page 40: One Day National Workshop on Common Effluent Treatment Plants

Page 40

Foundation

Anchor bolting case-2

Anchor bolting case-1

Concrete pad

Page 41: One Day National Workshop on Common Effluent Treatment Plants

Page 41

Air FiltersFirst stagePre filter

Secondary stageMedium filter

Filter Cover

Motor Room

Pre 85%@ 10 ㎛4-8 weeks

Final 99%@ 10 ㎛ or 68%@2 ㎛5-12 months

ΔP 21-44mmWTR

Page 42: One Day National Workshop on Common Effluent Treatment Plants

Page 42

Customers

Page 43: One Day National Workshop on Common Effluent Treatment Plants

Page 43

Customers

Page 44: One Day National Workshop on Common Effluent Treatment Plants

Page 44

Thank You!Godrej & Boyce Mfg. Co. Ltd.

Compressed Air SolutionsGodrej | Electrical & Electronics

Pirojshanagar, Vikhroli, Mumbai – 400079. IndiaTel.: +91-22-67962251 to 2255

Fax: +91-22-67961410 / 67961525E-mails: [email protected]; [email protected]; [email protected];

www.godrej-airsolutions.com