ontinuous emissions monitoring system · laser em® ontinuous emissions monitoring system 1300 850...

2
LaserCEM® Connuous Emissions Monitoring System Descripon The LaserCEM is a complete pre-calibrated mulcomponent (NO, NO2, NOx, SO2, CO, HCl, CO2, H2O, H2S, NH3, N2O, COS, SO3, CH4, HF) laser Infrared Spectrometer. LPS The LaserCEM features the exclusive LPS Low Pressure Sampling System enabling efficient installaon and reduced operang cost by eliminang the need for heatedsampling system. OFCEAS The LaserCEM uses the patented OFCEAS (WO 03031949) IR laser technology for enhanced specificity, selecvity, accuracy and stability (no span or zero driſt ). LaserCEM® Key Features 1300 850 862 I www.aquagas.com.au I [email protected] I 3 Wirranina Place - Currumbin - 4223 QLD True Direct Extracve CEMS (No sample treatment) - 100mbar sampling pressure removes any risk of chemical adsorpon, desorpon and condensaon along the sample line. Interferences Free - OFCEAS technology provides exceponal selecvity, enabling simultaneous monitoring of mulcomponent without interferences, regardless of the gas matrix. Ease of integraon - The LaserCEM allows digital (Ethernet, RS485, RS232, ModBus) analogue and TDR IOs. No Driſt - The zero is contained in the signal, enabling automated and intrinsic zero driſt compensaon. Field proven - The LaserCEM is free of opcal moving part and was designed and built strictly for industrial and on-board mobile applicaons. Low maintenance - The LPS system allows flow low rates within 3 and 9l/h without affecng the response me and re- ducing considerably dust and materials build-up. Applicaons The LaserCEM is designed for Connuous Emissions Monitoring in a large field of applicaon including gas and coal fired power staon, pharmaceucal and chemical industries, refineries, cement plants and waste incinerators and more...Highly durable to harsh process condions , the LaserCEM is a field proven, reliable, robust, cost-effecve and user friendly soluon for Connuous Emissions Monitoring. AP2e The LaserCEM is designed and manufactured by AP2e in France and uses patented analysis and sampling technologies .

Upload: others

Post on 24-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ontinuous Emissions Monitoring System · Laser EM® ontinuous Emissions Monitoring System 1300 850 862 I I info@aquagas.com.au I 3 Wirranina Place - urrumbin - 4223 QLD GAS RANGES

LaserCEM® Continuous Emissions Monitoring System

Description The LaserCEM is a complete pre-calibrated multicomponent (NO, NO2, NOx, SO2, CO, HCl, CO2, H2O, H2S,

NH3, N2O, COS, SO3, CH4, HF) laser Infrared Spectrometer.

LPS The LaserCEM features the exclusive LPS Low

Pressure Sampling System enabling efficient

installation and reduced operating cost by

eliminating the need for “heated” sampling system.

OFCEAS The LaserCEM uses the patented OFCEAS

(WO 03031949) IR laser technology for enhanced

specificity, selectivity, accuracy and stability (no

span or zero drift ).

LaserCEM® Key Features

1300 850 862 I www.aquagas.com.au I [email protected] I 3 Wirranina Place - Currumbin - 4223 QLD

True Direct Extractive CEMS (No sample treatment) - 100mbar

sampling pressure removes any risk of chemical adsorption,

desorption and condensation along the sample line.

Interferences Free - OFCEAS technology provides exceptional

selectivity, enabling simultaneous monitoring of

multicomponent without interferences, regardless of the gas

matrix.

Ease of integration - The LaserCEM allows digital (Ethernet,

RS485, RS232, ModBus) analogue and TDR IOs.

No Drift - The zero is contained in the signal, enabling

automated and intrinsic zero drift compensation.

Field proven - The LaserCEM is free of optical moving part and

was designed and built strictly for industrial and on-board

mobile applications.

Low maintenance - The LPS system allows flow low rates

within 3 and 9l/h without affecting the response time and re-

ducing considerably dust and materials build-up.

Applications The LaserCEM is designed for Continuous Emissions Monitoring in a large field of application including gas

and coal fired power station, pharmaceutical and chemical industries, refineries, cement plants and waste

incinerators and more...Highly durable to harsh process conditions , the LaserCEM is a field proven,

reliable, robust, cost-effective and user friendly solution for Continuous Emissions Monitoring.

AP2e The LaserCEM is designed and manufactured by AP2e in France and uses patented analysis and

sampling technologies .

Page 2: ontinuous Emissions Monitoring System · Laser EM® ontinuous Emissions Monitoring System 1300 850 862 I I info@aquagas.com.au I 3 Wirranina Place - urrumbin - 4223 QLD GAS RANGES

LaserCEM® Specifications

INTEGRATION

Dimensions

Weight

Standard 19” 4U rack unit - 550mm depth

20kg

Flow 3 to 9 lph

Sample Temp 600C

Pressure 1 atm. +/- 100mbar at the

sampling point

Sampling Line No heating required if:

Ambient temp> 10C and H2O<40% vol.

Heating required if:

Ambient temp<10C and H2O>40% vol.

Drift None

Response time 200s max. depending on sample line

Interface 5.7” touch screen

Windows XP / WinProceas

Output Ethernet / RS485 / RS232 / ModBus

Options ATEX - Wall mount version

Power supply 110-240 VAC 50/60 Hz - 200W

Operating

conditions Temp 15-35C Pressure 86-108kPa

Compressed air 1-6 bar (oil free)

LaserCEM® Continuous Emissions Monitoring System

1300 850 862 I www.aquagas.com.au I [email protected] I 3 Wirranina Place - Currumbin - 4223 QLD

GAS RANGES DETECTION LIMIT

SO2 0 to 25ppm 0.22 ppm

NO 0 to 60 ppm 0.09 ppm

HCl 0 to 10 ppm 0.01 ppm

NH3 0 to 10 ppm 0.01 ppm

CO 0 to 60 ppm 0.22 ppm

H2O 0 to 40 % 0.1 %

O2 0 to 25 % 0.05 %

CO2 0 to 20% 0.06 %

SO3 0 to 25 ppm 0.20 ppm

N2O 0 to 100 ppm 0.09 ppm

CH4 0 to 100 ppm 0.11 ppm

NO2 0 to 25 ppm 0.08 ppm