![Page 1: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/1.jpg)
© 2005 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice
OpenVMS Support for c-Class Blades
John ShorttHP OpenVMS Engineering27-Sep-2007
![Page 2: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/2.jpg)
October 11, 2007 2
Topics
• Features of HP c-Class Blade systems
• What makes up a c-Class Blade system
• OpenVMS Plans
• Using c-Class Blade systems−Configuring Hardware
− Firmware Updates
− Provisioning (Installation)
−Management
![Page 3: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/3.jpg)
October 11, 2007 3
Features of HP c-Class Blade Systems?
![Page 4: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/4.jpg)
October 11, 2007 4
Why c-Class Blades
• High cost of IT infrastructure
• Cost of acquisition vs. cost of ownership
• Inflexible IT infrastructure
• Speed in introducing IT change
• Space savings – more compute power in a smaller footprint compared to equivalent number of processors in racked servers
• Cable management and fewer cables to connect servers to LAN/SAN
![Page 5: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/5.jpg)
October 11, 2007 5
Why c-Class Blades (cont)
• Power/cooling efficiencies – Reduce Cost!
• Ease of management – more consistency across OS/architecture
• Flexibility – easy to change
• Fewer spare parts
• All of the above translate into lower cost of acquisition and cost of ownership compared to discrete servers
![Page 6: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/6.jpg)
October 11, 2007 6
A cross-HP solution platform
HP Active Cool fans and HP Dynamic Power Saver:HP Cool Team meets high density power/cooling problems head-on
HP Onboard Administrator:HP printer and copier LCD meet datacenter control
HP StorageWorks storage bladesStorageWorks inside the enclosure. A new storage solution paradigms for modular storage
Workstation and client bladesExtending the blading impact to more of IT
Infrastructure automationPolicy-based management solutions automate common and labor intensive tasks
HP Integrity and ProLiant server bladesScale-Out meets Scale-Up creating new blade paradigms for modular computing solutions
![Page 7: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/7.jpg)
October 11, 2007 7
BL860c Server Blade
![Page 8: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/8.jpg)
October 11, 2007 8
BL860c Server Blade
• 2 Processor Sockets− Single or Dual-core Itanium Processor− 1.6GHz/6MB cache− 1.4GHz/12MB cache− 1.6GHz/18MB cache
• 12 DIMM slots− DDR2 in 512MB to 4GB modules− Configured in pairs or quads, 1GB to 48GB
• Fast Core or Integrated IO− LSI 1068 Serial Attach SCSI (SAS) controller
• One channel for each on-board SAS drive• Drives are Hot Plug
− 2 Broadcom BC5704S Gigabit Ethernet controllers• 2-port controller• Both are routed to the Interconnect Module in Row 0
• 3 PCI Express (PCIe) Mezzanine card slots− Slot 1 is a Type I slot (x4)− Slots 2 and 3 are Type II slots (x8)
![Page 9: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/9.jpg)
October 11, 2007 9
BL860c
• Management Logic−Management Processor (MP)
−USB 2.0 controller
−ATI RN50 Graphics chip
−10/100MB ―internal‖ LAN connection
−Serial/USB/Video (SUV) connector
− iLO2 interface
− vMedia
−Virtual keyboard/video/mouse (vKVM) support• Windows today
• Other OS support in future FW releases
![Page 10: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/10.jpg)
October 11, 2007 10
BL860c Mezzanine Cards
• Type I cards− 15W max power
− x4 or x8 data lanes
− Can go in Type I or Type II slots
• Type II cards− 25W max power
− x8 Type II slots only
• 4GB Fibre Channel− Compatible with Integrity server FC
• PCIe pass-thru− Supports Storage Blade SB40c
• Expect to see others…NIC, Raid, FC …
![Page 11: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/11.jpg)
October 11, 2007 11
Integrity BL860cInternal View
SAS backplane
2 cells,12 DDR2 DIMM slots
zx2
ASIC
CPU power podsProcessor/heatsink assembly
CPU 1CPU 0TPM
Front panel
Front
Mezzanine sockets:
• #2 (x8)
• #1 (x4)
• #3 (x8)
2 hot-plug
SAS drive
bays
![Page 12: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/12.jpg)
October 11, 2007 12
The Enclosure
![Page 13: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/13.jpg)
October 11, 2007 13
c7000 Enclosure
• 10U form factor
• Fits in a standard 19‖ rack, 32‖ deep
• Capacity−8 full-height or 16 half-height Blade slots
−8 Switch Module (SWM) slots
−2 On-board Administrator (OA) slots
−6 Hot pluggable power supplies
−10 Hyperjet Coolers
![Page 14: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/14.jpg)
October 11, 2007 14
c7000 Enclosure
Half-Height Blade Server
• Up to 16 per enclosure
Full-Height Blade Server
• Up to 8 per enclosure
Integrated power
• Simplified configuration and greater efficiency
• Same flexibility, capacity and redundancy
Onboard Administrator• HP Insight Display, set-up simplification
10U
![Page 15: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/15.jpg)
October 11, 2007 15
c7000 Enclosure – fully redundant
Active Cool fans
Interconnect bays
Onboard Administrator
Power management
![Page 16: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/16.jpg)
October 11, 2007 16
c7000
HP c-Class
• Separate signal and power midplanes
• Passive signal midplane with 1 active component that is not in the signal path
• Solid copper plates make up power backplane
• 24-layer PCB which provides over 1600 high quality copper traces
C-Class Signal midplane C-Class Power backplane
![Page 17: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/17.jpg)
October 11, 2007 17
Interconnect/Switch Modules
• Rear of the enclosure contains 8 slots for SWMs
• Configured as 4 rows of 2 slots or bays (R0-R3)
• Row 0 dedicated to integrated Network connections−2 NICs per Blade, 2 ports each, 32 max ports
− Each SWM handles 16 ports
• Three types today− Pass-thru
−Vendor switch
−Virtual Connect
![Page 18: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/18.jpg)
October 11, 2007 18
c7000 Interconnect Routing
Server IO Interconnect Bay Comments
NIC1 and NIC2 1 and 2 Integrated Ports
Mezz Slot 1 3 and 4 Type I slot
Mezz Slot 2 5 and 6 (Primary)
7 and 8 (Secondary)
Type II slot
Mezz Slot 3 7 and 8 (Primary)
5 and 6 (Secondary)
Type II slot
![Page 19: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/19.jpg)
October 11, 2007 20
Virtual Connect
• Network and Fibre Channel SWMs plus Virtual Connect Manager (VCM)− VCM runs on Network SWM in bay 1 or bay 2 (at least one
Network VC switch is required for VC support)
− With 2 network switches you get redundant network paths and VCM failover—highly recommended
− Create VCM domain that describes your VC environment• Blade profiles
• Networks
• SANs
• Virtual Connect provides a “wire once” infrastructure
• VCM adds no overhead to Network and FC transfers!
![Page 20: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/20.jpg)
October 11, 2007 21
16x 1Gb Ethernet–Connects to one NIC in each HH blade server bay
1x 10Gb–Cross-link between adjacent VC-Enet modules
Mgmt Interfaces to Onboard Administrator (Enet & I2C)
HP Virtual Connect Ethernet Module
MidPlane
8x 1Gb Ethernet (RJ45)Usable as data center links or as stacking links.
‗Next‘ button (unused in initial release firmware)
Port Number & Status IndicatorsIndicates whether a data center link (green),stacking link (amber), or highlighted port (blue).
2x 10Gb Ethernet (CX4)Usable as data center links or as stacking links.
Recessed module reset button
![Page 21: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/21.jpg)
October 11, 2007 23
On-board Administrator (OA)
• Manages all enclosure related items – thermal, power, Switch Modules, Blades
• 2 Slots in the rear of the enclosure
• Interfaces−HTML-based GUI via HTTPS
−CLI interface via RS-232 (Local connector), SSH, or Telnet
• Management Protocols−SNMP today
![Page 22: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/22.jpg)
October 11, 2007 24
OA
− IPMI via iLO on local 10/100 link
• eKey to link Mezzanine card with SWM
• Power on control for Blade
• Dynamic Power and Cooling control− Enclosure Profile – setup once
− Real time monitoring data
• Firmware updates
• SWM console interface
![Page 23: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/23.jpg)
October 11, 2007 25
c3000 Enclosure
• 6U Form Factor
• New Midplane and Power Supply
• Capacity−4 full height/8 half-height slots
−6 Power Supplies
−6 Fans
−4 Interconnect bays
−1 OA
−DVD
![Page 24: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/24.jpg)
October 11, 2007 26
C3000
![Page 25: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/25.jpg)
October 11, 2007 27
c3000 Midplane Routing
Server IO Interconnect Bay Comments
NIC1 and NIC2 1 Integrated Ports
Mezz Slot 1 2 Type I slot
Mezz Slot 2 3 and 4 Type II slot
Mezz Slot 3 3 and 4 Type II slot
![Page 26: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/26.jpg)
October 11, 2007 28
Other Blades
![Page 27: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/27.jpg)
October 11, 2007 29
SB40c Storage Blade
• Direct Attach storage
• Smart Array raid controller
• Support for up to 6 SAS drives
• Connects to adjacent Processor Blade with PCIe pass-thru mezzanine card−Half-height Blades put module in mezz slot 2
− Full height Blades put module in mezz slot 3
−Can go in either slot of a partition (left or right of the pair)
![Page 28: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/28.jpg)
October 11, 2007 30
![Page 29: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/29.jpg)
October 11, 2007 31
Ultrium 448c Tape Blade
• LTO Ultrium 2
• 400GB capacity
• Requires PCIe Pass-thru module in mezzanine slot 3 of adjacent Server Blade
• Supported on Proliant today, Integrity around the end of the year
![Page 30: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/30.jpg)
October 11, 2007 32
PCI Sidecar
• IO Blade for PCIx or PCIe stand up modules−Comes with a ―backplane‖ for each
− Install the desired flavor
− Each has 2 available slots
• Support for 3rd party modules only—no HP modules are supported
• Released for Proliant Blades today, Integrity end of the year
![Page 31: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/31.jpg)
October 11, 2007 33
OpenVMS Plan
![Page 32: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/32.jpg)
October 11, 2007 34
OpenVMS Plan
• Base c-Class support June 1, 2007−V8.3 with update/patch kits
−SB40c (added support in July)
−Virtual Connect (added support in Sept)
• Additional features in release V8.3-1H1Nov 2007− Provisioning
−Web Based Enterprise Management (WBEM Providers)
− vMedia
−Montvale
− c3000 Enclosure
![Page 33: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/33.jpg)
October 11, 2007 35
Using c-Class Blade Systems
![Page 34: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/34.jpg)
October 11, 2007 36
Configuring the c-Class Blade System
• Questions−Mixed Integrity and Proliant Server Blades?
−Storage Blades?
− Redundant Network connections?
− Redundant FC connections?
− Redundant airflow?
− Redundant power?
−Virtual Connect?
![Page 35: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/35.jpg)
October 11, 2007 37
Adding c-Class Blades
• General rule is left to right installation
• Half-height Blades can be stacked, as well as half-height Blades on top of Storage Blades
• There is no requirement that empty slots are to be avoided
• Blades can be added or removed without powering off anything
• Remember, all server slots are routed to each interconnect slot
• Mezzanine cards must be configured based on Interconnect module requirements
![Page 36: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/36.jpg)
October 11, 2007 38
Adding Interconnect Modules
• Network modules must be placed in Bay 1 and/or Bay 2−Both for redundancy
− For VC, both for VCM failover
• Bays 3-8 depend on mezzanine cards−Bays 3 and 4 relate to mezz slot 1
−Bays 5 and 6 (7 and 8) to mezz slot 2
−Bays 7 and 8 (5 and 6) to mezz slot 3
![Page 37: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/37.jpg)
October 11, 2007 39
Mezz-1
NIC 21
4321
Mezz-2
4321
PCIe x4
PCIe x4
PCIe x8Inter. Bay 7 Inter. Bay 8
Inter. Bay 2Inter. Bay 1
Inter. Bay 4Inter. Bay 3
Inter. Bay 6Inter. Bay 5
N N
N N
N N
N N
Half-Height Server Blade N(N= 1 …. 16)
16 Lanes per connector
Inter. Bay 1Inter. Bay 3
Inter. Bay 5
Inter. Bay 7
Inter. Bay 2Inter. Bay 4
Inter. Bay 6
Inter. Bay 8
XX
Up to up to 10Gb/s per lane
Up to 160 Gb/s per direction.
c7000 Interconnect Model(Half-Height Server Blade)
![Page 38: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/38.jpg)
October 11, 2007 40
c7000 Interconnect Model(Full-Height Server Blade)
Up to 320 Gb/s per direction. Mezz-1
NIC 21
4321
Mezz-2
4321
PCIe x4
PCIe x4
PCIe x8
Inter. Bay 7 Inter. Bay 8
Inter. Bay 2Inter. Bay 1
Inter. Bay 4Inter. Bay 3
Inter. Bay 6Inter. Bay 5
N
32 Lanes per FH
Inter. Bay 1Inter. Bay 3Inter. Bay 5Inter. Bay 7
Inter. Bay 2Inter. Bay 4Inter. Bay 6Inter. Bay 8Full-Height Server Blade
N (N= 1 …. 8)
NIC 21
PCIe x4
Mezz-3
4321
PCIe x8
N + 8
![Page 39: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/39.jpg)
October 11, 2007 41
c-Class Power and Airflow
• Power Supplies−Minimum Slot 1 and Slot 4−4 to 6 supplies provide redundancy—select AC or DC
• Fans−Minimum of 4 Fans—2 left and 2 right−8-10 for redundancy (middle empty with 8)
• Install everything and turn on standby power, the OA will go through its startup script−OA will ask for power redundancy scheme− If the fan quantity and/or power supply number is
inadequate the OA will let you know
•
![Page 40: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/40.jpg)
October 11, 2007 42
Enclosure Module Access
• On-board Administrator−Get IP address from OA display
−Browse to the iLO
− TELNET to the CLI
−Serial Connection
−Use tag for OA name and password
−Configure IP, name, password, etc.
• Interconnect Modules− Local CLI
−Browse via OA
− Look for tag
![Page 41: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/41.jpg)
October 11, 2007 43
Management Processor Access
• TELNET to the Management Processor on each individual Blade− Traditional method of console access
• Browse to the MP (iLO2)
• ―SUV‖ cable for serial/USB/VGA connection to each Blade
• Use Tag for login information
• Future support for Virtual KVM (vKVM)
![Page 42: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/42.jpg)
October 11, 2007 44
Management Console Access
BL860c
Midplane
On-board Administrator
SM4
SWM3
SWM2
SWM1
BL860c
BL860c
Storage
Blade
Empty Slot
BL860c
Empty Slot
BL860c SM8
SWM7
SWM6
SWM5
SUV
10/100 Network
`Serial
SUV
1Gb Network
1Gb Network
1Gb Network
1Gb Network
4Gb FC
4Gb FC
4Gb FC
4Gb FC
![Page 43: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/43.jpg)
October 11, 2007 45
Check Firmware
• Update OA first
• Interconnect Modules
• Server Blade−Baseboard Management Controller (BMC)
−Management Processor (MP)
−System Firmware (SFW)
− Integrated IO (FRU EEPROMs for example)
−Mezzanine Cards
• Storage Blades
![Page 44: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/44.jpg)
October 11, 2007 46
01010011001010110111010001000111010111001010110100101011101001010101
HP BladeSystem usage scenarios
End-to-end provisioning
Provision solutions acrosscompute, network, and
storage in minutes
Patch and
vulnerability
Quickly assess and respond to potential
security vulnerabilities
Scheduled
re-provisioning
Improve system utilization through scheduled re-
provisioning
Deliver economical highavailability via resource
pooling and auto-recovery
Automated server
recoveryproduction spare
Dynamically scaleinfrastructure based on
performance needs
Dynamic scaling Rapid IT consolidation
Consolidate legacy compute nodes on high performance platforms
![Page 45: OpenVMS Support for c-Class Bladesde.openvms.org/TUD2007/TUD_Blades.pdfUp to 320 Gb/s Mezz-1 per direction. NIC 2 1 4 3 2 1 Mezz-2 4 3 2 1 PCIe x4 PCIe x4 PCIe x8 Inter. Bay 7 Inter](https://reader034.vdocuments.net/reader034/viewer/2022052017/602fa9fc02c0106acf36c1cb/html5/thumbnails/45.jpg)