Whatisaprogrammablethermostat? 2-4 Installation 5-6 Iconsexplained 6 TemperatureDisplay 7 SettingtheClock 7 SettingtheComfortLevels 8-9 KeypadLockFacility 9 TemperatureHold 10 SettingtheTemperature 10 HolidayFeature 11 TurningtheHeatingOn/Off 12 FactoryReset 12 OptionalThermostatSettings 13-17 Re-calibratingtheThermostat 18 Wiring 19-23

Page 4: Operating Instructions Model: PRT / PRT-N Version 3

2

What is a programmable room thermostat?

Aprogrammableroomthermostatisbothaprogrammerandaroomthermostat.Aprogrammerallowsyoutoset“On”and“Off”periodstosuityourownlifestyle.Aroomthermostatworksbysensingtheairtemperature,switchingontheheatingwhentheairtemperaturefallsbelowthethermostatsetting,andswitchingitoffoncethissettemperaturehasbeenreached.

So,aprogrammableroomthermostatletsyouchoosewhattimesyouwanttheheatingtobeon,andwhattemperatureitshouldreachwhileitison.Itwillallowyoutoselectdifferenttemperaturesinyourhomeatdifferenttimesoftheday(anddaysoftheweek)tomeetyourparticularneeds.

Turningaprogrammableroomthermostattoahighersettingwillnotmaketheroomheatupanyfaster.Howquicklytheroomheatupdependsonthedesignoftheheatingsystem,thesizeoftheboilersandradiators.

Page 5: Operating Instructions Model: PRT / PRT-N Version 3

3

Neitherdoesthesettingaffecthowquicklytheroomcoolsdown.Turningaprogrammableroomthermostattoalowersettingwillresultintheroombeingcontrolledatalowertemperature,andsavesenergy.

Thewaytosetanduseyourprogrammableroomthermostatis to find the lowest temperature settings that you are comfortablewithatthedifferenttimesyouhavechosen,andthenleaveitalonetodoitsjob.

Thewaytosetanduseyourprogrammableroomthermostatisto find the lowest temperature setting you are comfortable with, andthenleaveitalonetodoitsjob.Thebestwaytodothisistosettheroomthermostattoalowtemperature–say18°C–andthenturnitupby1°Ceachdayuntilyouarecomfortablewiththetemperature.Youwon’thavetoadjustthethermostatfurther.Anyadjustmentabovethissettingwillwasteenergyandcostyoumoremoney.

Ifyouheatingsystemisaboilerwithradiators,therewillusuallybeonlyoneprogrammableroomthermostattocontrolthewholehouse.Butyoucanhavedifferenttemperatures

Page 6: Operating Instructions Model: PRT / PRT-N Version 3

4

inindividualroomsbyinstallingthermostaticradiatorvalves(TRVs)onindividualradiators.Ifyoudon’thaveTRVs,youshouldchooseatemperaturethatisreasonableforthewholehouse.IfyoudohaveTRVs,youcanchooseaslightlyhighersettingtomakesurethateventhecoldestroomiscomfortable,thenpreventanyoverheatinginotherroomsbyadjustingtheTRVs.Thetimeontheprogrammermustbecorrect.SometypeshavetobeadjustedinspringandautumnatthechangesbetweenGreenwichMeanTimeandBritishSummerTime.

Youmaybeabletotemporarilyadjusttheheatingprogramme,forexample,“Override”,“Advance”or“Boost”.Theseareexplainedinthemanufacturersinstructions.

Programmable room thermostats need a free flow of air to sensethetemperature,sotheymustnotbecoveredbycurtains or blocked furniture. Nearby electric fires, televisions, wallortablelampsmaypreventthethermostatfromworkingproperly.

Page 7: Operating Instructions Model: PRT / PRT-N Version 3

5

Installation ProcedureDo’s1. Domountthethermostatateyelevel.2. Doreadtheinstructionsfullysothatyoucangetthebest

fromourproduct.

Don’ts1. Donotinstallnearadirectheatsourceasthiswillaffectthe

workingsofthethermostat.2. DonotpushhardontheLCDotherwiseyouwilldamagethe

liquidcrystaldisplayandthisisnotrepairable.

Installation

The thermostat is designed to be flush mount, a back box of 35mmshouldhavebeensunkinthewallpriortoinstallation.

Step1Carefullyseparatethefronthalfofthethermostatfromtheback plate by placing a small flat head terminal driver in to the slotsonthebottomfaceofthethermostat.

Page 8: Operating Instructions Model: PRT / PRT-N Version 3

6

Step2Placethethermostatfrontsomewheresafe.Terminatethethermostatasshowninthediagramsatthebackofthisbooklet.

Step3Clipthefrontofthethermostattothebackplate.

Icons Explained

Symbol Description

Heat On Icon Shown when the heating is On Flashing when the optimum starts is in operation

Frost On Icon (Heating Off) Shown when the heating is switched off and is protecting against frost only Keylock Icon Shown when the keypad is locked

Page 9: Operating Instructions Model: PRT / PRT-N Version 3

7

Temperature DisplayRoom Temp=Thisisthecurrentroomtemperature.

SET=Thisisthetemperatureyouaretryingtoachieveinyourhome.

Setting the ClockTosettheclock,followthestepsbelow.

• Withthethermostatturnedon,presstheClockbuttontwice.• YouarenowabletosettheminutesusingtheUp/Down

keys.• PressHtoaccept.• YouarenowabletosetthehoursusingtheUp/Downkeys.• PressHtoaccept.• YouarenowabletosetthedayoftheweekusingtheUp/

Downkeys.• PressAtostoreandexit.

Page 10: Operating Instructions Model: PRT / PRT-N Version 3

8

Comfort Levels ExplainedTheHeatmiserPRTprovidesWeekday/Weekendor7DayProgramming. You should consult the “Configuration Menu” sectiontoselecttherequiredmode.

Thethermostatissuppliedwithcomfortlevelsalreadyprogrammed,butthesecanbechangedeasily.Thedefaulttimesare:

08.00-21°C(Wake)09.30-16°C(Leave)16.30-22°C(Return)23.00-17°C(Sleep)

Ifyouonlywanttouse2levels,youshouldprogramtheunusedlevelsto--.--

• Tobeginprogrammingthecomfortlevels,pressClockOnce.• IfyourthermostatissetupforWeekday/Weekend

Programming,youwillseeMon-Frishown.For7dayprogrammingyouwillseeMonday.

• UsingtheUp/Downarrowkeys,entertherequiredWaketime.

Page 11: Operating Instructions Model: PRT / PRT-N Version 3

9

• PressH.• UsingtheUp/Downarrowkeys,entertherequiredWake

Temperature.• PressH.• Youwillnowsee“Leave”.• Youshouldrepeattheprogrammingforeachperiod,

entering--.—forunusedperiods.

Note:Forweekday/weekendProgramming,the4comfortlevelsarethesameforallweekdays.For7dayprogramming,eachdaycanhave4differentcomfortlevels.

Locking The Thermostat

Thethermostathasakey-lockfacility.Toenablefollowthesesteps:

• PressandholdtheAandDownKeyfor10seconds.• Youwillseethelocksymbolappear.• Tounlock,repeatthestepsabove.

Page 12: Operating Instructions Model: PRT / PRT-N Version 3

10

Temperature HoldThetemperatureholdfunctionisidealforpartiesorwhenyouwillbegoingoutforanumberofhours.Itallowsyoutoholdatemperatureforadesiredperiod.

• PressH.• UsingtheUp/Downarrowkeysentertherequiredholdtime.• PressH.• UsingtheUp/Downarrowkeysentertherequiredhold temperature.• PressAtoaccept.

YouwillseetheHoldindicationisdisplayedwhichwillcountdowntheholdduration.

Tocancel,reducetheHoldtimeto00hours.

Temperature SetUsingtheUporDownarrowkeysallowsyoutoadjustthesettemperature.Whenyoupresseitherofthesekeys,youwillseethewordSETandthedesiredtemperature.

PressAtoaccept.

Page 13: Operating Instructions Model: PRT / PRT-N Version 3

11

HolidayTheHeatmiserPRThasaholidayfunction.Thisallowsyoutoenteraholidaysetting.Duringaholiday,thethermostatwillmaintainthefrostsettemperature.Attheendofyourholiday,thethermostatwillrevertbacktotheprogrammedsettingensuringthatyourhomeiswarmonyourarrival.

• PressHthreetimes(Untilyouseethesuitcase).• UsingtheUp/Downarrowkeysenterthenumberofdays

holiday.• PressAtoaccept.

TheHeatmiserPRTwillshowasuitcaseindicatingthethermostatisinholidaymode.Tocancel,reducetheHolidaydurationto00days.

Page 14: Operating Instructions Model: PRT / PRT-N Version 3

12

Heat On / OffFrost Protect Mode:PressingthePowerbuttononcewillplacethethermostatinfrostprotectmode.Inthismode,thethermostatwilldisplaythefrosticonandwillonlyturntheheatingonshouldtheroomtemperaturedropbelowthesettemperature(seepage14)Shouldtheheatingbeturnedonwhilst in frost mode, the flame symbol will be displayed. To cancelthefrostprotectmode,presstheOnbutton.

Thermostat Off:Toturnthethermostatoffcompletely,pressandholdtheOffbutton.Thedisplayandheatingoutputwillbeturnedoff.Toturnthethermostatbackon,presstheOnbutton.

Factory ResetThethermostathasafactoryresetfunction.Thiswillresetallsettingsbacktotheirfactorydefault.Toperformafactoryreset,followthesesteps:

• Turnthethermostatoff(Seeabove).• PressandholdthePowerandUparrowkeyuntiltheLCD

powersup.Alloftheiconswillbedisplayed.Whentheyhavedisappeared,thethermostathasbeenreset.

Page 15: Operating Instructions Model: PRT / PRT-N Version 3

13

THE FOLLOWING SETTINGS ARE OPTIONALAND IN MOST CASES NEED NOT BE ADJUSTED

Optional Features Explained

Feature 01 - Temperature Format:Thisfunctionallowsyoutoselectbetween°Cand°F.

Feature 02 – Switching Differential:Thisfunctionallowsyoutoincreasetheswitchingdifferentialofthethermostat.Thedefaultis1°Cwhichmeansthatwithasettemperatureof20°C,thethermostatwillswitchtheheatingonat19°Candoffat20°C.Witha2°Cdifferential,theheatingwillswitchonat18°Candoffat20°C.

Feature 03 – Frost Protect:Youcansetwhetherthethermostatwillmaintainthefrosttemperaturewhenthethermostatdisplayisturnedoff.Asadefault,thisisenabled.

Page 16: Operating Instructions Model: PRT / PRT-N Version 3

14

Feature 04 – Frost Protect Temperature:Thisisthetemperaturemaintainedwhenthethermostatisinfrostmode.Therangeis07-17°C.Thedefaultis12°Candissuitableforalmostallapplications.

Feature 05 – Output Delay:Topreventrapidswitching,anoutputdelaycanbeentered.Thiscanbesetfrom00-15minutes.Thedefaultis00whichmeansthereisnodelay.

Feature 06 – Communication Address:Thissettingisusedwhenyouhaveconnectedyourthermostattoanetworksystem.Eachthermostatonyournetworkmusthaveauniquecommunicationaddress.Thiscanbesetfrom01-32.

Feature 07 – Temperature Up/Down Limit:Thisfunctionallowsyoutolimittheuseoftheupanddowntemperaturearrowkeys.Thislimitisalsoapplicablewhenthethermostatislockedandsoallowsyoutogiveotherslimitedcontrolovertheheatingsystem.

Feature 08 – Sensor Selection:Thisthermostathasabuiltinairsensor.

Feature 09 – Floor Temp Limit:Thisfunctionisnotavailableonthismodel.

Page 17: Operating Instructions Model: PRT / PRT-N Version 3

15

Feature 10 – Optimum Start:Optimumstartwilldelaythestartupoftheheatingsystemtothelatestpossiblemomenttoavoidunnecessaryheating,sothatthedwellingiscomfortablywarmbytheprogrammedtime.Thethermostatusestherateofchange(seebelow)settingtocalculatehowlongthebuildingneedstotaketoraisethebuilding1°C(witharateofchangeof20,thethermostathascalculatedthebuildingneeds20minutestoraisethebuilding1°C).

Feature 11 – Rate of Change:Forinformationonly.

Feature 12 – Weekday/Weekend or 7 Day Programming:Thethermostatofferstwoprogrammingmethods.Weekday/Weekendallowsyoutoprogram4comfortlevelsfortheweekdayand4differentcomfortlevelsfortheweekend.In7dayprogrammode,eachdayhas4comfortlevelsthatcanbeprogrammedindependently.

Page 18: Operating Instructions Model: PRT / PRT-N Version 3

16

Adjusting the Optional Settings1. To access the configuration menu, turn off the thermostat

bypressingandholdingdownthePowerButton.Then,pressandholdtheClockbuttonuntilthedisplaylightsup.

2. Thesmallnumberisthefeaturenumber,thelargenumberisthesettingvalue.

3. Usetheclockbuttontocyclethroughthefeatures.4. UsetheUp/Downkeystochangethesetting.5. PressAtoacceptandstore.

Feature Table Feature Description Setting

01 TemperatureFormat 00=°C 01=°F

02 SwitchingDifferential 01-03°C 01°CDefault

03 FrostMode 00=Enabled 01=Disabled (00=Default)

Page 19: Operating Instructions Model: PRT / PRT-N Version 3

Feature Table (continued) 04 FrostTemperature 07-17°C (12°CDefault)

05 OutputDelay 00-15Minutes (00Default)

06 CommunicationID SetUniqueComms Address01-32

07 Up/DownTempLimit 00-10°C (00°CDefault)

08 SensorSelection Builtinsensor

09 FloorLimitingSensor Notusedonthismodel

10 OptimumStart 00-03(00hoursdefault)

11 RateofChange Informationonly

12 Weekday/Weekend 00=Weekday/Weekend 01=7dayprogramming

17

Page 20: Operating Instructions Model: PRT / PRT-N Version 3

Re-calibrating the thermostat

Ifyouneedtore-calibratethethermostatfollowtheseinstructions:

1. Pressandholdthepowerbuttontoturnthethermostatoff.2. PressandholdBOTHthepoweranddownbuttonsuntilthe

temperatureappearsonthescreen.3. Usetheup/downbuttonstosetthenewtemperature.4. PressAtoaccept.5. Pressthepowerbuttononcetoturnthethermostatback

on.

18

Page 21: Operating Instructions Model: PRT / PRT-N Version 3

19

L N A1 A2

PRT

PRT 240V SWITCHING

LN E

BOILER

MAINS SUPPLY INN L E

RECOMMENDATIONSMAX CABLE SIZE 1.5MMBACK BOX DEPTH 35MMMAX LOAD 3 AMPS

Page 22: Operating Instructions Model: PRT / PRT-N Version 3

20

LN NC NO

PRT

PRT 240V CHANGEOVER SWITCHING

N

VALVE

RECOMMENDATIONSMAX CABLE SIZE 1.5MMBACK BOX DEPTH 35MMMAX LOAD 3 AMPS

COM

EOPEN

CLOS

E

L NMAINS SUPPLY IN

Page 23: Operating Instructions Model: PRT / PRT-N Version 3

21

L N A1 A2

PRT

PRT VOLTFREE SWITCHING

LN

E

BOILER

MAINS SUPPLY INN L E

Boiler thermostat ortimeclock connections

RECOMMENDATIONSMAX CABLE SIZE 1.5MMBACK BOX DEPTH 35MMMAX LOAD 3 AMPS

Page 24: Operating Instructions Model: PRT / PRT-N Version 3

22

+ A1A2 - RT1 RT2

Y B

COMMSCABLE

PRT-N 240V SWITCHING

12v

- + A2 B2

L E N C NC NO C NC NO

POWERED RELAY CARD

MAINS IN TO BOILER

RECOMMENDATIONSMAX CABLE SIZE 1.5MMBACK BOX DEPTH 35MMMAX LOAD 3 AMPS

LEN

Page 25: Operating Instructions Model: PRT / PRT-N Version 3

23

+ A1 A2 - RT1 RT2

Y B

COMMSCABLE

PRT-N VOLTFREE SWITCHING

12v

- + A2 B2

L E N C NC NO C NC NO

POWERED RELAY CARD

MAINS IN TO BOILER THERMOSTAT CONNECTIONS

RECOMMENDATIONSMAX CABLE SIZE 1.5MMBACK BOX DEPTH 35MMMAX LOAD 3 AMPS

Page 26: Operating Instructions Model: PRT / PRT-N Version 3

24

Page 27: Operating Instructions Model: PRT / PRT-N Version 3
Page 28: Operating Instructions Model: PRT / PRT-N Version 3

SupportTel:01254870303

®