Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us”. * Trademark of General Electric Company; may be registered in one or more countries. ©2011, General Electric Company. All rights reserved. AP-MpwPRO_RO_AP_EN (1).doc Dec-11 OPERATION AND MAINTENANCE MANUAL PRO AP Series Reverse Osmosis System Revision A December 2011 Prepared For: Client Name Plant Location Prepared By: GE Power & Water - Water & Process Technologies No.1 Hua Tuo Rd. ZhangJiang, Hi-Tech Park Pudong, Shanghai China 201203 Phone: (8621) 3877 7888 http://www.ge.com/water NOTICE The enclosed materials are considered proprietary property of GE Water & Process Technologies. No assignments, either implied or expressed, of intellectual property rights, data, know-how, trade secrets or licenses of use thereof are given. All information is provided exclusively for the addressee for the purposes of evaluation and is not to be reproduced or divulged to other parties, nor used for manufacture or other means, or to authorize any of the above, without the express written consent of GE Water & Process Technologies. The acceptance of this document will be construed as an acceptance of the foregoing conditions. * Trademark of General Electric Company; may be registered in one or more countries.

Upload: ngothuy

Post on 16-May-2018

231 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2011, General Electric Company. All rights reserved.

AP-MpwPRO_RO_AP_EN (1).doc Dec-11

OPERATION AND MAINTENANCE MANUAL PRO AP Series Reverse Osmosis System

Revision A

December 2011

Prepared For:

Client Name

Plant Location

Prepared By:

GE Power & Water - Water & Process Technologies

No.1 Hua Tuo Rd.

ZhangJiang, Hi-Tech Park

Pudong, Shanghai China 201203

Phone: (8621) 3877 7888

http://www.ge.com/water

NOTICE

The enclosed materials are considered proprietary property of GE Water & Process Technologies. No assignments, either implied or expressed, of intellectual property rights, data, know-how, trade secrets or licenses of use thereof are given. All information is provided exclusively for the addressee for the purposes of evaluation and is not to be reproduced or divulged to other parties, nor used for manufacture or other means, or to authorize any of the above, without the express written consent of GE Water & Process Technologies. The acceptance of this document will be construed as an acceptance of the foregoing conditions. * Trademark of General Electric Company; may be registered in one or more countries.

Page 2: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client
Page 3: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A TABLE OF CONTENTS

February 2017 i-1

TABLE OF CONTENTS

1 GENERAL INFORMATION ..................................................................... 1-1

1.1 The Manual .........................................................................................................1-1

1.2 Safety Summary ..................................................................................................1-1

1.3 Applications ........................................................................................................1-2

1.4 Piping Recommendations ....................................................................................1-3

1.5 Principles of Operation ........................................................................................1-3

1.6 Components of the PRO Series System .................................................................1-3

1.7 Instrumentation ..................................................................................................1-4

1.8 Electrical Package ................................................................................................1-6

1.9 Specifications ......................................................................................................1-7

1.9.1 Flow Specifications........................................................................................................ 1-7 1.9.2 Pressure Specifications ................................................................................................. 1-7 1.9.3 Feedwater Requirements ............................................................................................. 1-7 1.9.4 Permeate Flow Rate ...................................................................................................... 1-8 1.9.5 Concentrate Flow Rate ................................................................................................. 1-8 1.9.6 Pressure Range ............................................................................................................. 1-8 1.9.7 Membrane Rejection .................................................................................................... 1-8 1.9.8 Environmental Requirements ....................................................................................... 1-9

1.10 Flow Description ............................................................................................ 1-10

1.10.1 Inlet Flow ................................................................................................................ 1-10 1.10.2 High-Pressure Flow ................................................................................................. 1-11 1.10.3 Permeate Flow ........................................................................................................ 1-12 1.10.4 Concentrate Flow ................................................................................................... 1-12

1.11 Storing and Shipping Your Machine ................................................................ 1-13

1.11.1 Short term shutdowns ............................................................................................ 1-13 1.11.2 Long term shutdowns ............................................................................................. 1-13 1.11.3 Preventing Freezing ................................................................................................ 1-15 1.11.4 Draining Machine ................................................................................................... 1-15

1.12 Service Assistance .......................................................................................... 1-16

2 INSTALLATION ..................................................................................... 2-1

2.1 Rigging Instructions .............................................................................................2-1

2.1.1 Covered Van Delivery .................................................................................................... 2-1 2.1.2 Container Shipment ...................................................................................................... 2-1

2.2 Installation Considerations ..................................................................................2-2

2.2.1 Location ........................................................................................................................ 2-2 2.2.2 Mounting Requirements ............................................................................................... 2-2 2.2.3 Feedwater Requirements ............................................................................................. 2-2 2.2.4 Temperature ................................................................................................................. 2-2 2.2.5 Piping ............................................................................................................................ 2-3

Page 4: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ TABLE OF CONTENTS Rev A

i-2 February 2017

2.2.6 Power and Electrical Requirements .............................................................................. 2-3 2.2.7 Inlet Water Connections ............................................................................................... 2-4 2.2.8 Connections .................................................................................................................. 2-4

3 SYSTEM OPERATION ............................................................................ 3-1

3.1 Initial Start-up .....................................................................................................3-1

3.1.1 Pre-Treatment for Water Purification........................................................................... 3-1 3.1.2 Start-Up ......................................................................................................................... 3-2

3.2 Control Narrative .................................................................................................3-6

3.3 Daily Start-Up Procedure .....................................................................................3-6

3.4 Shut Down Procedure ..........................................................................................3-7

4 MAINTENANCE .................................................................................... 4-1

4.1 Daily Maintenance Requirements ........................................................................4-1

4.1.1 Daily Log Sheet .............................................................................................................. 4-1 4.1.2 Record Pressure Gauge Readings ................................................................................. 4-2

4.2 Weekly Maintenance Requirements .....................................................................4-2

4.2.1 Replace Pre-Filter .......................................................................................................... 4-2 4.2.2 Record RO Temperature ............................................................................................... 4-3

4.3 Monthly or Quarterly Maintenance Requirements ...............................................4-3

4.3.1 Membrane Element Cleaning ....................................................................................... 4-3 4.3.2 Review Operating Data ................................................................................................. 4-3

4.4 Annual Maintenance Requirements .....................................................................4-4

4.5 Maintenance Procedures .....................................................................................4-4

4.5.1 Pre-Filter Replacement Procedure................................................................................ 4-4 4.5.2 Membrane Cleaning Procedure .................................................................................... 4-5 4.5.3 Membrane Removal Procedure .................................................................................... 4-5 4.5.4 Membrane Installation Procedure ................................................................................ 4-6 4.5.5 Pump Bearing Frame Lubrication ................................................................................. 4-7

4.6 Spare Parts List ....................................................................................................4-8

4.7 Level Switch, Level Transmitter or Other External Controls ...................................4-9

4.8 Chemical Pump .................................................................................................. 4-10

5 TROUBLESHOOTING ............................................................................ 5-1

6 MISCELLANEOUS ................................................................................. 6-1

6.1 Return Goods Authorization (RGA) Procedure ......................................................6-1

6.2 Machine Warranty/Guarantee .............................................................................6-1

6.3 Membrane Element Warranty/Guarantee ............................................................6-5

6.4 Start-Up Data ......................................................................................................6-7

6.5 Daily Log Sheet ....................................................................................................6-9

Page 5: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A TABLE OF CONTENTS

February 2017 i-3

TABLE OF FIGURES AND TABLES

Table 1-1: Flow Specifications/Range 75% Recovery ...................................................... 1-7

Table 1-2: Feedwater Requirements ............................................................................... 1-7

Table 1-3: OSMO PRO 365 Membrane Element Specifications ...................................... 1-8

Table 2-1: Connections .................................................................................................... 2-4

Table 5-1: Troubleshooting Guide ................................................................................... 5-1

Figure 1-1: PRO Series Machine ........................................... Error! Bookmark not defined. Figure 1-2: Banking Array ............................................................................................... 1-11

Figure 1-3: Membrane Element ..................................................................................... 1-12

Page 6: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client
Page 7: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A GENERAL INFORMATION

February 2017 1-1

1 GENERAL INFORMATION

1.1 The Manual

This manual has been prepared to provide the operator with information on the

installation, operation, maintenance, and troubleshooting of PRO Series Reverse

Osmosis machines.

The manual may be supplemented with drawings, schematics, and Technotes for

clarification.

1.2 Safety Summary

Words in ENHANCED CAPITAL letters are used to identify labels on the device and key

safety or qualifying statements.

The safety summary does not contain all of the safety statements in the manual. Other

safety statements are included within the manual text and are enhanced and defined as

follows:

NOTE

Indicates statements that provide further information and

clarification.

CAUTION!

Cautions indicate statements that are used to identify conditions

or practices that could result in equipment or other property

damage.

WARNING!!

Warnings indicate statements that are used to identify conditions

or practices that could result in injury or loss of life.

Page 8: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ GENERAL INFORMATION Rev A

1-2 February 2017

!

IMPORTANT!

Important warnings refer to hazards or unsafe methods or

practices that can result in product damage or related equipment

damage.

READ THIS MANUAL: Prior to operating or servicing this device, this manual must be

read and understood. Keep this and other associated manuals for future reference and

for new operators or qualified service personnel.

USE PROPER POWER CONNECTIONS: Use proper wiring connection methods to satisfy

local electrical codes.

DO NOT REMOVE OR OPEN COVERS OR PANELS: To avoid electrical shock hazard, do

not remove covers or panels when power is supplied to the device. Do not operate the

device when covers or panels are removed. If a panel must be removed for

troubleshooting purposes, use extreme caution.

SHOCK HAZARD: Connect this device to a properly grounded connection in accordance

with the National Electrical Code and any other local codes or ordinances that apply. DO

NOT, under any circumstances, remove the ground wires or ground prong from any

power plug. Keep the floor surface under the RO free of water.

DEVICE LABELING: Do not, under any circumstances, remove any Caution, Warning, or

other descriptive labels from the device until the conditions of warranting the label are

eliminated.

DO NOT OPERATE IN FLAMMABLE ATMOSPHERES: To avoid fire or explosion, do not

operate this device in an explosive environment.

1.3 Applications

The PRO AP Series Reverse Osmosis (RO) System is designed to purify water by forcing

water through a semi-permeable RO membrane. Water purified by reverse osmosis has

had approximately 97 – 98% of the dissolved ions and approximately 99% of most other

contaminants removed. The quality of the purified water, referred to as permeate,

depends on many parameters, including the quality of the feedwater and correct

operation and maintenance of the equipment.

Page 9: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A GENERAL INFORMATION

February 2017 1-3

1.4 Piping Recommendations

Piping materials can significantly contribute to the contamination of water. Most

metallic pipes (with the exception of stainless steel) must not be used for transferring

high purity permeate water following the RO machine. Schedule 80 PVC pipes,

polypropylene, PVDF, and other FDA recommended materials are suitable for most

grades of purified water. Care must also be exercised in the choice of a thread sealant.

Teflon* tape is suitable for all threaded connections in this system.

WARNING!!

Ordinary pipe dope must be avoided since it may leach

objectionable and potentially dangerous impurities into the

water.

1.5 Principles of Operation

Your machine is a durable piece of equipment, which with proper care, will last for many

years. PRO machines are designed for a wide variety of industrial and commercial

applications. Contact your GE Water & Process Technologies sales representative with

any questions concerning potential applications.

1.6 Components of the PRO Series System

Automatic Inlet Valve

The automatic inlet valve is actuated with air. A solenoid valve controls the automatic

flow of air to this valve. The inlet valve is closed whenever the machine is shut down,

which keeps feed water from flowing through the machine at low pressures.

*Teflon is a trademark of E.I. DuPont de Nemours and Company, Inc.

Page 10: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ GENERAL INFORMATION Rev A

1-4 February 2017

One-Micron Pre-filter

All machines have a depth cartridge pre-filter system located near the feedwater inlet of

the machine. The filters are nominally rated at one micron, so all particles larger than

one micron will be removed from the inlet stream. The filter system is meant to protect

the RO membrane elements from large particles, which could be damaging. The number

of filter housings varies with the size of machine. Typically, other forms of filtration

precede the cartridge pre-filters.

Membrane Elements

All machines utilize GE Water & Process Technologies’ turbulent flow membrane

elements to provide high mineral rejection, low-pressure drop, and high flow rates.

Membrane Element Housings

GE Water & Process Technologies four-port side entry Fiberglass Reinforced Plastic

housings simplify machine design and membrane element change-out. GE Water &

Process Technologies port-to-port dimension allows for a compact machine design

providing the most water production in the smallest footprint.

Pumps

All machines are equipped with Grundfos Multi-stage Centrifugal pumps. The pumps are

specifically designed to deliver consistent high-pressure flow ideal for membrane system

operation. The liquid ends of these pumps are very sophisticated and maintenance

should only be performed by authorized Grundfos personnel.

1.7 Instrumentation

Conductivity Probe

All machines feature a permeate conductivity probe. Conductivity, measured in

microSiemens per centimeter (µS/cm), is a measure of the dissolved minerals (ionic

impurities). The cleaner the permeate, the lower the conductivity reading.

High Pressure Switch

Page 11: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A GENERAL INFORMATION

February 2017 1-5

All machines feature two high-pressure switches. These switches shut down the

machine if permeate or concentrate pressure exceed a preset level. These switches

should not have the set point values increased to prevent potentially dangerous

situations from occurring.

PH Probe

Machines with Premium electrical package feature a pH probe on the inlet of the RO

machine, while it is optional on machines with Basic electrical package. This probe

monitors feed pH to control acid or caustic addition. The machine will shut down if this

pH reading exceeds the high or low pH set points. The chemical addition for pH is

controlled through a 4-20 mA Proportional Integral Derivative (PID)

Low Inlet Pressure Switch

All machines feature a low inlet pressure switch. This switch shuts the machine down if

the feedwater pressure drops below a level that is considered damaging to the pump.

Oxidation Reduction Potential (ORP)

All machines feature an Oxidation Reduction Potential (ORP) probe as optional addition

on the inlet. This probe monitors for the presence of oxidants such as chlorine or

chloramines in the feedwater, which are harmful to the membrane elements. The high

ORP alarm set point is adjusted at start-up to 10% below a known chlorine-free

background, typically 180 – 200mv. A hand-held chlorine monitor should be used to

verify chlorine-free operation and ORP settings at start-up and once a week.

Permeate and Concentrate Flow Meters

All machines include flow meters for permeate and concentrate streams. The flow

meters are paddle wheel type flow meters. Water flowing through the meter spins the

paddle wheel like a pinwheel. The spinning turbine emits a magnetic pulse. The cable

carries the signal to the flow monitor where the signal is translated into a digital flow

reading.

Pressure Gauges

Page 12: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ GENERAL INFORMATION Rev A

1-6 February 2017

All machines include stainless steel, glycerin-filled pressure gauges mounted into various

locations in the machine’s piping to yield pre-filter, post-filter, primary, final, permeate,

concentrate, and pump discharge pressure readings.

Instrument Controller

Machines with the Basic electrical package include a Signet 8900 Multiparameter

controller. This controller features digital monitoring of the permeate/concentrate

flows, conductivity, temperature and optional pH and ORP. The controller has four

programmable relays some of which are used for alarms. The 8900 Multiparameter also

has configurable analog (4 – 20 mA) outputs that transmit data to the machines PLC or

can be used to send data to the user’s data acquisition or control system. Machines that

have the Premium electrical package do not need the Signet 8900 Multiparameter

controller as the sensors transfer the data directly to the machines PLC.

1.8 Electrical Package

Basic Electrical Package

The basic model machine utilizes a GE Fanuc Micro Versamax Series Programmable

Logic Controller (PLC) to control the machine’s operation. A GE Fanuc Quick Panel 6.0-

inch is used for message display and system control.

Premium Electrical Package

The premium model machine utilizes a GE Fanuc Versamax and a GE Fanuc Quick Panel

12-inch touch screen. The Premium Electrical Package includes a feed conductivity

probe and two pressure transmitters for primary and final pressure display.

Page 13: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A GENERAL INFORMATION

February 2017 1-7

1.9 Specifications

1.9.1 Flow Specifications

The machine flow specifications listed below are based on a feedwater temperature of

68°F (20°C).

Table 1-1: Flow Specifications/Range 75% Recovery

Permeate Rate (m3/h)

Concentrate Rate (m3/h)

Recycle Rate (m3/h)

Feed Rate (m3/h)

PRO – 11 11.4 3.8 3.0 15.1

PRO – 23 22.7 7.5 2.3 30.2

PRO – 34 34.1 11.4 - 45.4

PRO – 45 45.4 14.9 4.5 60.4

PRO – 68 68.1 22.7 - 90.8

PRO – 102 102.2 34.1 -- 136.3

** Flow rates can vary ±5%.

1.9.2 Pressure Specifications

The machines typically operate at a primary pressure of 14.2 – 16 bar with a 3 - 6 bar

pressure drop across the membrane elements.

1.9.3 Feedwater Requirements

The following feedwater requirements must be met before installing your new machine

to ensure quality permeate and extended membrane element life.

Table 1-2: Feedwater Requirements

Temperature Minimum: 2°C**

Design: 20°C

Maximum: 30°C

Inlet Pressure Minimum: 2 bar

Maximum: 4 bar

Total Dissolved Solids (TDS) Maximum: 1,000 mg/L

Chloride Ion Maximum: 350 mg/L (consult with GE Water and Process Technologies if chloride level in feedwater is higher).

Page 14: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ GENERAL INFORMATION Rev A

1-8 February 2017

Chlorine (continuous feed) 0 ppm

Iron < 0.1 ppm

LSI Negative

Operating pH 4 – 9

Silt Density Index (SDI)15 < 5

** The system will produce far less permeate at the minimum temperature.

1.9.4 Permeate Flow Rate

Stated in Table 1-1: Flow Specifications/Range 75% Recovery.

Efforts should be taken to limit the permeate flow when operating at higher

temperatures. Do not allow the machine to produce more than 20% above the rated

permeate flow.

1.9.5 Concentrate Flow Rate

Stated in Table 1-1: Flow Specifications/Range 75% Recovery.

The flow control device can be manually adjusted to maintain between 75-80%

recovery.

1.9.6 Pressure Range

To estimate the RO pump boost pressure, use the formula below:

Boost Pressure = (Primary Pressure) – (Post-filter Pressure)

The machine’s typical primary pressure will need to be adjusted for different water

temperatures in a range between 14.2 – 16 bar.

1.9.7 Membrane Rejection

Your machine uses GE Water & Process Technologies Fiberglass Reinforced Plastic (FRP)

covered OSMO PRO 365 membrane elements with Thin Film Composite (TFC)

membrane elements. For ordering information refer to the Spare Parts List (Section 4.6).

Table 1-3: OSMO PRO 365 Membrane Element Specifications

Page 15: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A GENERAL INFORMATION

February 2017 1-9

Outer Cover Material FRP

Typical Ionic Rejection (TDS)** 99.0 – 99.5%

Permeate Flow Rate at 15.5 bar 10,000 gpd (37.9 m3/day)

Typical Feedwater Temperature Range 10 – 30°C

Maximum Temperature Range 0 – 50°C

pH Range 4.0 – 11.0

Chlorine Tolerance < 0.01 ppm

Active Membrane Area 365 ft2 (34 m2)

Average Molecular Weight Cutoff*** 150 MW

** Based on 24 hours of operation at 15.5 bar 25°C, 7 – 8 pH, 2000 ppm NaCl solution.

***The molecular weight cutoff is based on the pore size of the membranes and the nature (size/shape)

of the organic molecule.

1.9.8 Environmental Requirements

Ambient Temperature: 5 – 32°C

CAUTION!

This machine must not be allowed to freeze. Irreparable harm to

various components, including RO membranes may occur. See

Section 1.11.3.

NOTE

This machine is designed for indoor operation only.

NOTE

If this unit is operating in a humid environment, the

user/operator should recognize that moisture can be caused by

condensation and is not necessarily an equipment leak.

Page 16: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ GENERAL INFORMATION Rev A

1-10 February 2017

1.10 Flow Description

1.10.1 Inlet Flow

The feedwater passes through a stainless steel, seven-round cartridge filter housings.

These housings are filled with replaceable one-micron cartridge filters, which remove

bulk suspended solids (Figure 1-1: PRO Series Machine).

Error! Reference source not found.In certain cases five-micron cartridge filters can also

be used. The pressure is measured before and after the cartridge filter housings. These

readings are the pre- and post- filter pressures, displayed by the gauges on the piping

before and after the filter housing(s). Filtered water then flows to the inlet control valve.

When the RO is turned ON, the valve opens, allowing water to flow to the pump inlet.

When the RO is turned OFF, the valve closes, preventing low velocity, non-turbulent

flow through the membrane elements, which would lead to fouling, scaling, and

shortened membrane element life. Both pH and ORP measurements are taken prior to

the pump inlet.

NOTE

If an external control device is used (level switches, level

transmitter, etc.), the on/off switch would always be in the on

position. In this case, the external control switch controls the

state of the inlet control valve.

1.10.2 High-Pressure Flow

The centrifugal pump boosts the water pressure and feeds water to the eight-inch

diameter membrane element housings. Line pressure is measured between the pump

discharge and the inlet of the first housing. This measurement is the primary pressure.

The membrane element housings are horizontally mounted and arranged in series and

parallel combinations. An arrow label on the side of each housing indicates the direction

of flow. The membrane element housings separate the water into two streams. Water

that passes through the membrane element (which is filtered or purified) leaves the

housing as permeate, and water that does not pass through the membrane element

Page 17: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A GENERAL INFORMATION

February 2017 1-11

leaves the housing as concentrate. Note that the direction of flow indicators refer only

to concentrate flow. Permeate will flow out of the open (not-plugged) end of the

housing, regardless of concentrate flow direction (Figure 1-2: Banking Array) (Figure 1-3

Membrane Element)

Figure 1-1: Banking Array

Figure 1-2: Membrane Element

Page 18: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ GENERAL INFORMATION Rev A

1-12 February 2017

1.10.3 Permeate Flow

The permeate leaves each housing and is collected into a common manifold. This stream

flows through the permeate flow meter to the permeate outlet of the machine. The

conductivity of the stream is measured before the permeate exits the machine. This

measurement is the permeate conductivity. Both the permeate flow and conductivity

readings are displayed. It is important to not have excessive permeate back pressure. A

check valve is present in the permeate piping to prevent backflow of permeate through

the membrane elements.

1.10.4 Concentrate Flow

The concentrate leaves the last membrane element housing and flows to the

concentrate outlet. Line pressure is measured between the outlet of the last housing

and the concentrate orifice. This measurement is the final applied membrane pressure.

Both the recycle and concentrate orifices are integral in controlling the operating

pressure and recovery of the machine. The recycle flow diverts a fraction of the

concentrate back to the pump inlet. Recycling a portion of the concentrate allows the

system to achieve a higher volumetric recovery. It also ensures that enough water is fed

to the membrane elements to provide adequate crossflow. Some units do not require

this. Concentrate passes through the concentrate orifice to the concentrate flow meter

and on to the concentrate outlet. The instrument center displays the concentrate flow.

The concentrate orifice controls the amount of concentrate that leaves the machine. At

the same time, it provides the restriction necessary to control the operating pressure of

the machine. A V-notch ball valve is mounted before the orifice to provide some

adjustment capability.

1.11 Storing and Shipping Your Machine

If your machine is to be shutdown for extended periods of time, special steps must be

taken to properly protect it from bacteriological contamination.

When an RO machine is shut down, careful consideration must be paid to storage

procedures in order to minimize the potential for microbiological growth in the system.

Stagnant, untreated conditions create a thriving environment for microbiological

organisms. Over time, a biofilm will form and it can be very difficult to remove.

Page 19: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A GENERAL INFORMATION

February 2017 1-13

1.11.1 Short term shutdowns

Short term shut down of an RO system (24-48 hours) generally does not require special

membrane storage procedures. The RO should be cycled (run in operational mode) for

at least 15 minutes every 24-48 hours to reduce the potential for bio-growth and

stagnation within the system. Some systems use a permeate flush during shutdown.

This type of cycling will allow the system to remain “operationally” ready, and it will

allow for a slightly longer time between flush cycles.

1.11.2 Long term shutdowns

For prolonged storage (i.e. several days to several months), the following procedures

are recommended. These procedures will help protect and preserve the elements from

bacterial growth. The elements can be left in their housings or unloaded and stored

separately.

Typically, one of the following lay-up solutions is used depending upon application,

regulatory limitations, preference, and chemical availability:

1. 0.5 to 1.0% sodium bisulfite or 3.0% BetzDearborn DCL30

2. Isothiazoline-based non-oxidizing biocide such as Biomate MBC781 according to

EPA use-limitations.

3. 1.0 to 2.0% citric acid or 4% Betz MPH5000; 2% Kleen MCT442; 10% Kleen

MCT882.

NOTE

DBNPA-based biocides such as Biomate MBC2881 have been

successfully used for membrane lay-up, however some

membrane manufacturers do not recommend using this

chemistry due to the potential by-products formed by a long-

term hydrolysis mechanism.

The following procedure is recommended for RO storage in sodium bisulfite or biocide

solution.

Page 20: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ GENERAL INFORMATION Rev A

1-14 February 2017

1. Clean the membrane elements via standard clean-in-place procedures, and

thoroughly rinse the RO system.

2. Prepare the appropriate strength sodium bisulfite or biocide solution in the CIP

tank by diluting with permeate water.

3. Circulate the solution through the RO system for 15 to 20 minutes.

4. When the RO system is filled with this solution, close the valves to retain the

solution in the RO.

5. Repeat Steps 2 and 3 with fresh solution every thirty days if the temperature is

below 80°F (27°C), or every fifteen days if the temperature is above 80°F (27°C).

6. When the RO system is ready to be returned to service, flush the system to drain

until the permeate water meets quality specifications, then return the machine to

service.

NOTE

Over time, sodium bisulfite will become oxidized and form

sulfuric acid, lowering the pH. The pH of the lay-up solution

should be monitored monthly and fresh solution added if the pH

drops to pH=3 or lower, in order to safeguard the membranes.

An alternate procedure that requires less maintenance specifies the use of citric acid or

a low pH cleaning solution to “Pickle” the system. The following procedure is

recommended:

1. Clean the membrane elements via standard clean-in-place procedures, and

thoroughly rinse the RO system.

2. Prepare the appropriate strength citric acid solution in the CIP tank by diluting

with permeate water.

3. Circulate the solution through the RO system for 15 to 20 minutes.

4. Shut the RO system down.

Page 21: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A GENERAL INFORMATION

February 2017 1-15

5. Valve off CIP tank and drain tank.

6. Leave the acid solution in the RO machine.

The elements can remain in the housings for over a year without any change in element

performance, provided the storage temperature is below the maximum element

operating temperature.

BE SURE TO THE FOLLOW START-UP PROCEDURE (Section 3.1.2) before putting the

machine back in service.

1.11.3 Preventing Freezing

If your machine is to be shipped or stored under circumstances that might cause

freezing, completely drain the machine of all remaining water. Failure to do so may

result in damaged piping. Do not the restart machine until it has been thawed for at

least 24 hours.

1.11.4 Draining Machine

Prior to shipping or outside storage the system should be cleaned with the appropriate

cleaner, flushed with water, and protected from biological attack with an appropriate

solution. The membrane housings and piping lines of the machine must be completely

drained. Any water remaining in the plumbing of a machine may freeze, causing damage

to the piping, pump, membranes, etc.

1. Disconnect the inlet, concentrate, and permeate outlets.

2. Drain all water from the pre-filter housing(s).

3. Open the vent valves on top of the pre-filter housing(s).

4. Remove the piping connections on the outlets of the membrane housings.

5. Open the concentrate valve.

6. Open all sample and drain valves.

7. Remove the drain plug from pump discharge and inlet plumbing and remove the

Victaulic clamp and gasket on the pump discharge.

Page 22: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ GENERAL INFORMATION Rev A

1-16 February 2017

8. Allow the machine to drain for a minimum of eight hours or until the opened

ports quit dripping.

9. Reconnect all of the plumbing.

1.12 Service Assistance

If service assistance is required, take the following steps:

1. Consult the TROUBLESHOOTING Section of this manual (Section 5). If the

problem cannot be identified and corrected by any of the procedures found in that

section, then:

2. Call the GE Water & Process Technologies Field Service Group at (8621) 3877

7888.

Prior to making the call, have the following information available:

RO model you have.

The serial number of your PRO (on the nameplate attached to the face panel).

Detailed description of the problem.

Operation and Maintenance Logs. Current operating parameters (i.e. flow,

operating pressures, pH, etc.).

Last time cleaned.

Page 23: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A INSTALLATION

February 2017 2-1

2 INSTALLATION

2.1 Rigging Instructions

All equipment skids will be delivered in a covered van or flatbed truck.

2.1.1 Covered Van Delivery

The machine will not be crated, but will be secured inside the van with wood blocks,

straps, etc. All pieces of equipment that are wet tested at GE Water & Process

Technologies factory are completely drained to prevent ice damage.

Remove the equipment from the van at a loading dock using forklifts, pallet jacks, and

moving carts. All equipment frames are designed to allow lifting devices easy access at

the narrow ends.

2.1.2 Container Shipment

The machine will be shrink wrapped with plastic. The machine is secured in the

container with chains/straps and may be completely covered in shipping tarps for

protection. Miscellaneous instruments and manifold pieces may have been removed

from the RO for shipping purposes. In these cases, the loose parts will be put into a box

and strapped to the internal frame of the RO machine.

The skids should be picked from the container by placing lifting straps under the bottom

section of the frame. Spreader bars must be used to prevent the lifting straps from

damaging the internal structure of the equipment (pipe, instruments, enclosure, etc.).

Inspect each piece of equipment as it is received making note of any physical damage

to piping, pneumatic lines, instruments, gauges, or the frame. Notify the carrier

immediately if there is damage to the equipment that may have occurred during

shipment. Inspect each piece of equipment to verify all pieces listed on the packing

sheets are accounted for. Notify GE Water & Process Technologies immediately if

there are any missing pieces.

After each piece of equipment is removed from the flatbed truck, it should be placed in

its position in the water treatment room or stored indoors. Any loose items should be

kept together attached to their respective equipment skids or in boxes, pallets or crates

Page 24: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ INSTALLATION Rev A

2-2 February 2017

as appropriate. If the equipment cannot be stored indoors, all pieces must be kept

under a heavy-duty tarp or other material to protect from the elements.

2.2 Installation Considerations

2.2.1 Location

Select a location for your machine that is flat, near the required electrical and water

supply, provides adequate drainage and clearance for membrane element replacement

(Mounting Requirements, Section 2.2.2). GE Water & Process Technologies recommends

the machine be used indoors and sheltered from direct sunlight.

2.2.2 Mounting Requirements

Machines are equipped with a stand-alone frame, which supports the machine. When

setting up your machine, GE Water & Process Technologies recommends you take into

consideration the space needed to remove cartridge pre-filters from filter housings and

membrane elements from membrane element housings. The filter housings require

room above the housings and the membrane elements require room on the ends of the

machine. The membrane element housings require 5-feet (1.5 m) of clearance on both

ends of the machine. If adequate spacing is not available, the entire membrane element

housing may have to be removed for membrane element changes. The machine should

be leveled and evenly supported under the skid. GE Water & Process Technologies

recommends that the machine be anchored and/or grouted to a housekeeping pad,

depending on the local seismic codes and vibration requirements.

2.2.3 Feedwater Requirements

See Section 1.9.2: Pressure Specifications and Table 1-3: OSMO PRO 365 Membrane

Element Specifications for feedwater requirements.

2.2.4 Temperature

The performance specifications of the RO machine are based on a feedwater

temperature of 20°C. For each degree Celsius drop, the product flow is reduced by 3%

(refer to Temperature Correction Factors, Technote 113). The operator has the ability to

make some adjustments to the operating pressure with the pump discharge throttle

valve. In climates where winter water temperature drops significantly below 20°C it may

be necessary to heat the water or consider an alternative machine configuration.

Page 25: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A INSTALLATION

February 2017 2-3

WARNING!!

The temperature of the tempered water should be monitored

closely with a thermometer as high temperatures can damage

the RO membranes. Refer to the Feedwater Requirements

(Section 1.9.3) for the maximum operating temperature for the

RO machine.

CAUTION!

It is necessary to keep the RO from freezing to prevent serious

damage to the machine.

2.2.5 Piping

The piping used to transport the permeate and concentrate from the machine needs to

be designed to prevent backflow. The concentrate piping should have an atmospheric

break prior to entering the drainage system. If multiple RO machines are used, install

check valves into the concentrate piping at each machine prior to connecting the lines

into a common manifold. In addition, the drain should be sized to accommodate the

backwash of filter if on the same line.

2.2.6 Power and Electrical Requirements

WARNING!!

Before opening any electrical enclosure, make sure the main

power source to the machine is disconnected.

The electrical system control circuit is separate from the motor voltage. All field wiring

must comply with applicable local and national electric codes. The system requires

single-phase source (110-230 VAC, 50 Hz or 60Hz) supplied to the control enclosure and

a 3-phase source (380 VAC, 50 Hz or 60Hz) to the motor starter panel.

Page 26: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ INSTALLATION Rev A

2-4 February 2017

2.2.7 Inlet Water Connections

Special connections may be needed to the connect water supply. Connections vary

between facilities and local water authority codes.

Certain cities may require: a system shut-off valve, backflow preventer, pressure

regulator, surge suppressor, and/or a pressure relief device. Contact your local authority

or licensed contractor with any questions.

2.2.8 Connections

Table 2-1: Connections

PRO-11 PRO-23 PRO-34 PRO-45 PRO-68 PRO-102

Feedwater Inlet 2” 3” 3” 4” 4” 6”

Permeate Outlet 2” 3” 3” 3” 4” 4”

Concentrate Outlet

1.5” 1.5” 1.5” 2” 2” 3”

**All connections are ANSI 150# Flanges

Page 27: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A SYSTEM OPERATION

February 2017 3-1

3 SYSTEM OPERATION

3.1 Initial Start-up

3.1.1 Pre-Treatment for Water Purification

GE Water & Process Technologies RO systems will operate most efficiently on filtered

water with a pH of less than 7.0, negative LSI, and a Silt Density Index (SDI)15 of three (3)

or below. If the machine is operated on higher pH water or higher SDI, other forms of

pretreatment may be necessary. A water analysis prior to start-up of the machine is

required. To minimize the chances of calcium carbonate, calcium sulfate, or other

mineral precipitation on the membrane, GE Water & Process Technologies evaluates

each application and water condition and makes specific recommendations to assure

continuity of the membrane element warranty. Data from the water analysis is

processed with a computer program analysis to determine if potential problems may

exist. If the machine is to be run at a different location than was originally intended, a

new water analysis is required for warranty consideration and should be sent to GE

Water & Process Technologies for review and recommendations for operation of the

machine. Seasonal water conditions must also be taken into consideration.

Before entering the machine, the feedwater must be filtered to a minimum of 5

microns.

CAUTION

A water softener should not regenerate while the machine is

running unless safeguards are used to be sure the machine is

operated on softened water during regeneration.

Page 28: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ SYSTEM OPERATION Rev A

3-2 February 2017

3.1.2 Start-Up

NOTE

If your machine is provided with the membranes installed in the

housings, proceed with start-up. If your machine is provided with

the membranes in shipping boxes, you must load the membranes

in the housings prior to starting the machine. For membrane

loading instructions, go to Section 4.5.4. Upon completion of

membrane installation, return to this section and continue your

start-up procedure.

TFC membrane (only) must not contain the following chemicals or permanent loss of

rejection and/or permeate flow may result:

Free or Total chlorine

Ozone

Oils and greases or organic compounds

Iodine compounds

Quaternary germicides

Cationic surfactants

Detergents containing non-ionic surfactants

Cleaners other than those approved for use

Other oxidants

1. Re-check the function and integrity of your pretreatment equipment. Ensure

that your water softener, activated carbon filters, and/or multi-media filters (where

applicable) have been leak-checked, back washed, and thoroughly rinsed for service

before starting up your RO unit. Ensure that the various chemical feed systems are

primed with chemicals, tested for leaks, and connected to the feed line of the RO

unit.

Page 29: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A SYSTEM OPERATION

February 2017 3-3

2. Attach the feedwater piping to the inlet of the machine. Attach the discharge

piping to the permeate outlet connection which sends the purified water to the

storage tank or other process systems. Attach the discharge piping to the

concentrate outlet connection that sends the concentrated, or reject water, to a

drain or other process systems. Attach air supply and control voltage. GE Water &

Process Technologies recommends installing isolation valves on each of these lines.

See the Piping and Instrumentation Drawing (P&ID). Ensure that cartridge pre-filters

are installed.

3. Turn on the feedwater gradually and check for leaks in the inlet plumbing. No

flow should go through the machine while the power is off and the automatic inlet

valve is in the closed position.

NOTE

When the machine is off, there should never be flow through the

machine. Flow through the machine when it is off can

permanently damage the membrane elements.

4. Attach discharge plumbing or tubing to the Clean-In-Place (CIP) inlet, permeate

and concentrate connections, which sends water to and from the CIP tank. Connect

piping or tubing to the CIP drain direct. This drain connection will be used to direct

permeate water to drain during the start-up flush cycle.

GE Water & Process Technologies recommends installing isolation valves on each of

these lines. See the P&ID.

5. The machine requires two power supplies, (1) the high voltage for the motor

operation and (2) the control circuit power supply. Ensure that you have made

provisions for both power supplies required to operate your machine. Check the

voltage label to ensure that you have brought the correct voltage to the starter. See

Electrical Drawings.

!

IMPORTANT!

Appropriate motor starters must be selected depending on full

load amp draw for available voltage. The motor must be wired

for the appropriate voltage.

Page 30: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ SYSTEM OPERATION Rev A

3-4 February 2017

6. Be sure the power to the motor starter is de-energized.

7. With the power source to the motor starter de-energized, turn the

OFF/AUTO/HAND/FILL switch to the FILL position. Water will begin to flow through

the machine at this point but the pump will NOT start. Open the vent filter valves on

the top of the cartridge filter housings and the permeate sample ports on the

membrane element housings. This will permit air to exit the machine. Allow the

machine to operate in this manner for 10 minutes, to purge the air out of the

machine. Close these vent valves once a steady stream of water is expelled from

them.

8. As your machine is filling check for leaks and repair as needed.

9. After 10 minutes, turn the OFF/AUTO/HAND/FILL switch to the OFF position.

10. Energize the power source to the motor starter. The pump should not operate at

this point because the switch is in the OFF position.

11. Check the rotation of the high-pressure pump by briefly turning (e.g., bumping)

the OFF/AUTO/HAND/FILL switch to the HAND position. After five seconds, the high-

pressure pump will start. Immediately turn the switch to the OFF position. Watch, or

have an assistant watch, the motor or coupling shaft for direction of rotation. The

motor should rotate clockwise as you are looking down on to the motor end of the

high-pressure pump. If the motor is not rotating clockwise, change any two of the

three leads (for 3-phase) in the motor starter and recheck rotation. Always turn the

power OFF to change any wiring.

CAUTION!

Operation of the pump backwards for even a short time may

cause damage to the pump.

12. Open the concentrate valve slightly and turn the OFF/AUTO/HAND/FILL switch to

the HAND position. After a short delay, the high-pressure pump will start and the

machine will begin to build pressure.

Page 31: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A SYSTEM OPERATION

February 2017 3-5

Once the pressure has come up, adjust the concentrate valve to the proper flow

rate.

13. As the machine is operating, watch the primary and final pressure gauges. Refer

to Table 1-1: Flow Specifications/Range 75% Recovery and Section 1.9.2 Pressure

Specifications for average operating flows and pressures.

14. As the machine purges the air and fills with water, the pressure will gradually

increase. The permeate and concentrate flow meters should begin to detect flow,

displayed on the operation screen of the monitor. If you do not see flow after 30

seconds, turn the machine OFF and refer to TROUBLESHOOTING (Section 5).

CAUTION!!

Never allow the machine to operate without adequate water

pressure. This can cause severe damage to the high-pressure

pump.

15. If necessary, gradually adjust the concentrate valve. As you adjust the valve,

watch the final pressure gauge (Pfinal) and your concentrate flow meter. Opening the

concentrate valve will decrease operating pressure and closing the concentrate

valve will increase operating pressure. Adjust the valve until your concentrate flow

meter displays your design flow.

Your machine will generally operate at a recover rate of 70 – 80%. (Refer to Table

1-1: Flow Specifications/Range 75% Recovery for Flow Specifications and Rates.) To

adjust the recovery rate, contact the GE Water & Process Technologies Field Service

Group.

16. Typically, once the desired flow rate is achieved, no further valve adjustment is

needed unless temperature and/or pressure conditions change.

NOTE

Permeate flow rates are dependent upon temperature and

conditions at your site. Contact the GE Water & Process

Technologies Field Service Group if you have any questions.

Page 32: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ SYSTEM OPERATION Rev A

3-6 February 2017

17. Before putting the machine into final operation, continue to run the permeate

and concentrate streams to drain for at least 30 minutes. This is done to ensure that

all of the biocide has been removed from the membranes.

NOTE

The membranes in your machine are rated for certain flow rates

at 68°F (20°C). Maximum flow rates are achieved when the

membranes have been completely rinsed and on-line for at least

24 hours.

18. Record start-up performance data on the machine Startup Data Sheet (Section

6.4).

NOTE

A Daily Log Sheet (Section 6.5) that includes general operating

conditions (pressures, flows, concentrations, pH, and

pretreatment conditions), and routine or special maintenance

(cleaning as needed) must be kept. GE Water & Process

Technologies will require this log sheet if a warranty question

arises.

3.2 Control Narrative

See the Control Section of the water treatment system manual for control narrative.

3.3 Daily Start-Up Procedure

Check the machine to insure inlet, permeate, and concentrate valves are in the proper

positions for operation.

To turn the RO on, press the OFF/AUTO/HAND/FILL switch to the AUTO position if a

remote start signal or tank level controls the RO machine or HAND to operate manually.

If the alarm light is lit, push the “alarm reset” switch. If the alarm light stays lit, check

the RO for an alarm condition. If no alarm conditions exist, the main inlet valve will

open, and the high-pressure pump will turn on after a short delay. The RO machine will

shutdown in an alarm after 10-15 seconds if there is insufficient inlet pressure [<12 psig

(0.83 bar)].

Page 33: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A SYSTEM OPERATION

February 2017 3-7

Daily performance data must be recorded on the Daily Log Sheet (Section 6.5).

3.4 Shut Down Procedure

NOTE

Prior to shutting machine down, ensure that the Daily Log Sheet

(Section 6.5) has been completed. If not, complete before

shutting the machine down.

1. Turn the RO control OFF/AUTO/HAND/FILL switch to FILL.

2. The high-pressure pump will shut-off and the machine will perform a fresh water

flush (2-5 minutes of fresh water flush is recommended).

3. Turn the RO control OFF/AUTO/HAND/FILL switch to OFF.

4. The inlet valve will close all flow of water.

If the machine is in AUTO mode and controlled by an outside signal or tank level, it

will not be necessary to turn the machine off at the control screen unless it needs to

be taken out of service.

In AUTO mode a basic control system will automatically perform a fresh water flush

under low pressure for 5 minutes prior to shutting down. If the machine has the

premium electrical package the permeate will be diverted to the inlet of the

machine for 5 minutes prior to shutting down the high-pressure pump. Both

methods ensure that concentrated feedwater is flushed from the system before shut

down.

NOTE

During the fresh water flush permeate production will be

reduced to 25% or less of rated flow and permeate quality will

decline. See Control Narrative for details.

Page 34: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client
Page 35: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A MAINTENANCE

February 2017 4-1

4 MAINTENANCE

The operation and maintenance of your machine is relatively simple but requires regular

data recordings and routine preventative maintenance. GE Water & Process

Technologies cannot emphasize too strongly the importance of filling out the Daily Log

Sheet during each operating shift. You should have filled out a data sheet upon start-up

containing pertinent facts on the operation of your machine. These two records are

invaluable in diagnosing the performance of the equipment, or warranty issues, and

must be kept for reference. If you have questions concerning the operation of your

machine or the method of data recording, contact the GE Water & Process Technologies

Field Service Group.

The five preventative maintenance procedures that must be done on a regular basis are

as followed:

1. Maintain Daily Log Sheet (Section 6.5).

2. Change the pre-filter cartridges (Section 4.2.1).

3. Run the machine for at least 3 hours of operation every 72 hours.

4. Clean the machine as necessary (Section 1). GE Water & Process Technologies

recommends cleaning the machine monthly, or at a minimum once per quarter.

5. Change the oil in the pump as described in the pump’s operation and

maintenance manual.

Operator maintenance on a GE Water & Process Technologies RO system is limited to

maintaining performance logs, cleaning, calibration of instruments, and replacement of

damaged or failed parts. The maintenance procedures have been categorized by their

frequency and are as follows: (specific instructions follow the maintenance schedule).

4.1 Daily Maintenance Requirements

4.1.1 Daily Log Sheet

A Daily Log Sheet, which includes general operating conditions [pressure, flows,

instrument readings (pH, conductivity, etc.)] and routine or special maintenance (pre-

Page 36: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ MAINTENANCE Rev A

4-2 February 2017

filter changes, cleaning, etc.), must be kept. Copies of the log can be made from the

template (Section 6.5). GE Water & Process Technologies will require a copy of this log

sheet if a warranty question arises.

4.1.2 Record Pressure Gauge Readings

Observe and record the pre-filter, post filter, primary, and final pressure gauges on the

Daily Log Sheet.

4.2 Weekly Maintenance Requirements

The actions below should be performed in addition to the daily requirements.

4.2.1 Replace Pre-Filter

Cartridge filters were once considered only as a point-of-use water treatment method for removal of larger particles. However, breakthroughs in filter design, such as the controlled use of blown microfiber filters (as opposed to wrapped fabric or yarn-wound filters), have tremendously broadened cartridge filter utilization. Best Practice

A 1-micron pre-filter is factory-installed to protect the membranes and valves from

particles, which may be in the feedwater. The filter cartridges must be replaced after a

pressure drop of 0.5– 0.7 bar across the filter during operation or, at least, once a

month.

Filters can be changed based on scheduled time frequency. This can be dictated by the type of application or the end user requirement.

Use only GE Water & Process Technologies approved pre-filters rated for 5 microns or

less. Do not attempt to clean used filters. Discard and install new filters. To order

replacements, see the spare parts list section 4.6.

NOTE

Failure to change the filter according to these requirements will

void the warranty.

Page 37: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A MAINTENANCE

February 2017 4-3

4.2.2 Record RO Temperature

Observe or measure and record the RO temperature. This information is available from

the instrument display center. The RO temperature has a significant effect in the

permeate flow rate of the RO membrane elements.

4.3 Monthly or Quarterly Maintenance Requirements

The actions below should be performed in addition to the weekly requirements.

4.3.1 Membrane Element Cleaning

NOTE

Read and understand all cleaning instructions before beginning

process.

Cleaning your machine on a regular basis is vital. Over time, contaminants buildup to

form a layer on membrane element surfaces, reducing the permeate flow and quality. If

this build-up is not removed from the membrane element, it may cause permanent

damage and reduce the membrane element life. A decrease in permeate flow and/or

rejection of salts, or an increased pressure drop across the membrane elements (the

difference between the primary and final pressures) will indicate when cleaning is

required. Cleaning may be required as often as once every week or as infrequently as

every two months, depending upon the local water supply conditions. Refer to the

Membrane Cleaning Procedure.

GE Water & Process Technologies offers a full line of chemical cleaners for specific

cleaning needs. See the Kleen MCT Selection Guide.

4.3.2 Review Operating Data

Review operating data for any trends that might be cause for concern or additional

maintenance. For example, check operating data for a 5% or more change in flow,

rejection, or pressure differential. If any of these changes occur review the

TROUBLESHOOTING Section (Section 5).

Page 38: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ MAINTENANCE Rev A

4-4 February 2017

4.4 Annual Maintenance Requirements

The actions below should be performed in addition to the monthly requirements.

1. Check the instrument display monitor for accuracy.

2. Check the instruments for correct functioning. Check the pH and ORP probes

every six months. Replace or calibrate if necessary.

3. Check the tubing, gaskets, and fittings for leaks and wear. Replace if necessary.

4. Check the switches and lights for correct operation. Replace or repair if

necessary.

5. Check all pre-RO devices for correct operation. Replace if necessary.

6. Lubricate the motor. Refer to the pump’s operation and maintenance manual.

7. Check membrane element performance. The normal life span of a well-

maintained membrane is 2 – 3 years.

4.5 Maintenance Procedures

4.5.1 Pre-Filter Replacement Procedure

One-micron pre-filters are factory-installed to protect the high-pressure pump,

membranes, and valves from particles in the feedwater.

The pre-filter cartridges should be replaced regularly to minimize pressure drop and

help minimize biological growth. Weekly or biweekly replacement is typical. Use only GE

Water & Process Technologies approved filters rated for 5 microns or less. Do not

attempt to clean used pre-filters.

The pre-filters should be replaced before and after cleaning of the membranes

elements.

1. To change the pre-filter, turn the RO machine OFF, turn the water supply off.

Open the pre-filter vent tops and make sure no feedwater pressure exists.

Page 39: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A MAINTENANCE

February 2017 4-5

Open the pre-filter drain valves.

2. Remove the pre-filter housing tops by loosening the clamps.

3. Remove the old filters.

4. Install the new filters. Assure proper compression of the pre-filter springs,

indicated by a 2/3’s compression of the uncompressed spring length.

5. Re-install the pre-filter tops, close the pre-filter drain valves, and tighten the

clamps.

6. Open the feedwater supply, allow air to purge through the vents.

7. Close vents after a steady stream of water is produced.

NOTE

Failure to change pre-filters may void the machine warranty.

4.5.2 Membrane Cleaning Procedure

Refer to the Pro RO CIP Operation and Maintenance manual for membrane cleaning

procedures.

4.5.3 Membrane Removal Procedure

As time progresses, the effectiveness of the membrane elements will be reduced. Symptoms of reduced membrane element effectiveness include reduced rejection and permeate flow rate drift. Membrane element life can be extended with diligent cleaning of the machine. Precipitation of minerals can cause premature loss in rejection and even flow rate. The following procedure is to be followed to replace existing membrane elements in the machine. Reference Figure 1-2 Banking Array and

Figure 1-2: Membrane Element

1. Remove the setscrews on the end caps and remove the snap rings from the end

caps. Remove end caps from all of the membrane element housings.

Page 40: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ MAINTENANCE Rev A

4-6 February 2017

2. Remove all of the membrane elements from the membrane element housings in

the direction of flow (where possible). A heavy-duty pliers or channel lock pliers may

be necessary to pull the old membrane element out of the membrane element

housing. A long pole, pipe, pieces of 4 x 4, etc., may be used to push the old

membrane elements out of the housings.

4.5.4 Membrane Installation Procedure

For machines with membrane elements not loaded at the factory, the following steps

are to be used for installation.

CAUTION!

The membrane element may be packaged in a small amount of

bactericide solution to prevent biological growth; provide

adequate ventilation when handling.

NOTE

Take the necessary precautions when handling membrane

elements.

1. Remove the membrane bag containing the membrane element from the

shipping tube.

2. Cut the bag open as close as possible to the seal at the end of the bag, so that

the bag may be re-used if necessary.

3. Remove the membrane element from the bag and remove the foam protectors

from each end of the membrane element.

4. If you ordered the parts kit, inspect for damage. Make sure that all parts are

clean and free from dirt. Examine the O-rings, brine seal, and permeate tube for

nicks or cuts. Replace the O-rings or brine seal if damaged. If you are replacing

existing membrane elements, set the membrane element aside in a clean space, and

remove membrane elements (Membrane Removal Procedure Section 4.5.3).

Page 41: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A MAINTENANCE

February 2017 4-7

5. Inspect the membrane element housing and clean as necessary to remove any

contaminants, obstructions, etc.

6. Apply O-ring lubricant to all O-rings on the end caps, and the brine seal on the

membrane element. Typically, glycerin is used. Using very little lubricant or no

lubricant can make the installation process very difficult and can cause damage to

the O-rings and seals.

7. Insert the downstream end of the membrane element in the upstream end of

the membrane element housing (i.e., load in the direction of flow; the brine seal is

on the end of the membrane element that goes in last).

8. Insert the membrane element in the membrane element housing with a smooth

and constant motion. When you reach the point where the brine seal is about to

enter the housing, gently rotate the membrane to ensure the brine seal enters the

housing without coming out of the brine seal groove. Install the interconnectors in

between each membrane element, as well as between each membrane element and

the endcaps at both ends.

9. Re-install the end caps by gently twisting the end cap while pushing it onto the

interconnector and verifying the interconnector is sealed well with the element’s

permeate tube. Ensure that you do not pinch or fatigue any O-rings while pushing

the end cap on. Push the end cap on until the outer diameter of the cap is just past

the snap ring groove. Re-install the snap rings.

10. Re-connect any fittings that were removed when disassembling the membrane

housings.

If at initial start-up, return to Section 3.1.

11. Run the permeate and concentrate streams to drain for at least 30 minutes. This

is done to ensure that all of the biocide has been removed from the membrane

elements.

4.5.5 Pump Bearing Frame Lubrication

Refer to your pump’s operation and maintenance manual.

Page 42: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ MAINTENANCE Rev A

4-8 February 2017

4.6 Spare Parts List

For additional spare part details refer to your Piping and Instrumentation Diagram

(P&ID). Items described below are used on all models. Contact the GE Water & Process

Technologies Customer Support Center to order parts.

Description Part Number

Pre-Filters/Membrane Elements

1-micron, RO.Save 01-40 (20/ctn) 1236268 Membrane Element: PRO 365 WT 3044550

Instruments

Pressure gauge, SS, 63mm diameter, 40Bar, Bottom Mount 3016500 Pressure gauge, SS, 63mm diameter, 40 Bar, Back Mount 3016501 Pressure gauge, SS, 63mm diameter, 10Bar, Back Mount 3016502 Pressure gauge, SS, 40mm diameter, 10Bar, Back Mount (air line) 3016504 Inlet Pressure switch, 2.1 Bar. Set at 0.8 Bar - Falling 3016505 Perm/Conc Pressure switch, 14 Bar. Set at 5.5 Bar - Rising 3016506 Flow sensor, paddle wheel type 1117652 Conductivity sensor 3017445 pH sensor 3034593 ORP sensor 3034594

Valves

PVC sample valve, 1/4-inch 1156744 PVC sample valve, 3/8-inch , angle 1201698 SS drain ball valve, 1/2-inch 1226052 SS vent ball valve, 1/4-inch 1226020

50 Hz RO High Pressure Pumps/Motors

Pro-11: Pump and Motor, Grundfos CRN 15-14 A-FGJ-G-E-HQQE 3055211 Pro-23: Pump and Motor, Grundfos CRN 32-9-2 A-G-G-E-HQQE 3055213 Pro-34: Pump and Motor, Grundfos CRN 45-7-2 A-G-G-E-HQQE 3055214 Pro-45: Pump and Motor, Grundfos CRN 64-6-2 A-G-G-E-HQQE 3055215 Pro-68: 2 X Pump and Motor, Grundfos CRN 45-7-2 A-G-G-E-HQQE 3055214 Pro-102: 2 X Pump and Motor, Grundfos CRN 64-6 A-G-G-E-HQQE 3055216

Page 43: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A MAINTENANCE

February 2017 4-9

60 Hz RO High Pressure Pumps/Motors

Pro-11: Pump and Motor, Grundfos CRN 15-8 A-FGJ-G-E-HQQE 3055217 Pro-23: Pump and Motor, Grundfos CRN 32-6-2 A-G-G-E-HQQE 3055218 Pro-34: Pump and Motor, Grundfos CRN 45-5-2 A-G-G-E-HQQE 3055219 Pro-45: Pump and Motor, Grundfos CRN 64-4-2 A-G-G-E-HQQE 3055310 Pro-68: 2 X Pump and Motor, Grundfos CRN 45-5-2 A-G-G-E-HQQE 3055219 Pro-102: 2 X Pump and Motor, Grundfos CRN 64-4-1 A-G-G-E-HQQE 3055311

8-inch FRP Housing Parts

End Cap Seal 3012610 End Cap Retaining ring, 316 3021976 End Cap Adapter to membrane 3012611 End Cap Permeate Port Seal 3012621 End Cap Permeate Port O-Ring 3021973 Blank permeate tube, 815 series PVC 1118744 Side Port Seal, Curve 3012623 Side Port Seal 3012624

Literature

Pure Water Handbook 1154273

4.7 Level Switch, Level Transmitter or Other External Controls

It is possible to control your PRO machine externally.

The external controls option include:

4-20 mA transmitter signal (tank level)

Discrete ON/OFF signal (plant DCS system)

Discrete pretreatment lock-out signal

See Control Narrative for details.

Page 44: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ MAINTENANCE Rev A

4-10 February 2017

4.8 Chemical Pump

GE Water & Process Technologies has available multiple chemical injection systems with

control factory configured for pH control, antiscalant, or sodium sulfite addition. See the

Chemical Feed Systems Section of the water treatment system manual.

Page 45: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A TROUBLESHOOTING

February 2017 5-1

5 TROUBLESHOOTING

This troubleshooting guide can assist you in identifying common operating problems

you may experience with your machine. The operator can easily correct many of these

problems; however, for those that persist or are not understood, you should contact the

GE Water & Process Technologies Field Service Group. Have the following information

available when calling the GE Water & Process Technologies Field Service Group:

Machine installation date.

Model number (found on right-hand side of front panel).

Serial number (found on right-hand side of front panel).

Daily Log Sheets.

Detailed description of problem.

Table 5-1: Troubleshooting Guide

TROUBLESHOOTING GUIDE

Symptom (Alarm) Possible Cause Remedies

Low inlet pressure

(low inlet alarm)

Insufficient feedwater pressure Increase the feed pressure, open the inlet/feed valve, check for restrictions, and consider installing a feedwater boost pump.

Clogged pre-filter Replace the pre-filters.

Solenoid valve not opening Clean or replace the solenoid valve. Clean air line for adequate pressure. Check regulator for correct operation and setting.

Low operating pressure High flow rates Close the orifice bypass valve, check the permeate and concentrate flow rates and adjust if necessary. Excessive permeate flow may indicate improper interconnector installation.

Pump discharge screen

(low primary pressure)

Inspect and clean.

Page 46: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ TROUBLESHOOTING Rev A

5-2 February 2017

Dirty or fouled membranes

(low final pressure)

Clean the membranes.

Warm operating conditions Correct temperature.

Pump rotating backwards

(3-phase power only)

Switch any two 3-phase leads to the motor starter.

Pump not operating correctly See pump instructions.

High temperature

(High temp alarm)

Temperature too high Shut-off machine and let it cool down. Lower feedwater temperature.

If recirculating water, install cooling heat exchanger to prevent water heat up.

Switch set too low Follow procedure in instrument instruction manual to change switch setting.

Faulty temperature instruments Check instruments against reference standards and replace as necessary.

High/low inlet pH

(alarm)

pH out of range If pH is too low, the acid feed system may be over-injecting. Reset to maintain pH in middle of alarm setting or refer to machine specifications. Refer to chemical feed manual.

If pH is too high, check operation of acid feed system for proper operation. Refer to chemical feed manual.

Faulty pH probe Calibrate and check with reference standard. Clean or replace as necessary. Refer to pH meter manufacturer’s manual.

High ORP

(alarm)

Chlorine breakthrough Check setting and operation of sodium bisulfite system. Check for presence of chlorine. If using activated carbon upstream, check the condition of the carbon media.

Faulty ORP probe Recalibrate or replace ORP probe.

Page 47: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

_______________________________________________________________________ Rev A TROUBLESHOOTING

February 2017 5-3

Alarm set too low Verify chlorine-free water and raise alarm set point. See instrument instruction manual.

Low permeate flow rate Low operating pressure See the possible causes for low operating pressure.

Dirty or fouled membranes Clean the membranes.

Operating on cold water less than 55 - 60°F (13 - 16°C)

Install a hot/cold feedwater tempering valve if more permeate flow is needed. Operate with a feedwater temperature of 55 - 65°F (13 - 18°C).

Membranes installed backwards or damaged concentrate seal

Install membranes in the direction of fluid flow. Clean the machine immediately.

Membranes with damaged concentrate seals should be cleaned.

Flow meter inaccurate Check the flow rate manually with a stopwatch and calibrated container (such as CIP tank).

Low permeate flow rate (continued) Valve position Check CIP and outlet valve positions for correct orientation.

Low concentrate flow rate, normal or higher than normal pressure

Concentrate orifice plugged Remove the concentrate orifice and/or disassemble the plumbing. Clean the orifice.

Concentrate outlet line restricted Examine the concentrate line for obstructions or a closed valve.

Flow meter inaccurate Check the flow rate manually with a stopwatch and calibrated container. Note: CIP tank can be used for this purpose.

High operating pressure (high perm. Or conc. Alarm)

Recycle or concentrate lines plugged Disassemble the plumbing to the recycle orifice and remove foreign particles.

Inaccurate pressure switch setting Replace or calibrate the switch as required.

Service and CIP valves closed at the same time

Verify water path to both is open.

Page 48: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

_______________________________________________________________________ TROUBLESHOOTING Rev A

5-4 February 2017

Restricted or reduced permeate flow rate

See the possible causes for low permeate flow rate.

Excessive pressure drop [exceeding max ∆P] (high primary pressure – low final pressure)

Restricted flow after pump outlet Check for blockage of the concentrate flow at the inlets and outlets of the membrane housings. Check for blockage at the pump discharge screen.

Telescoped membrane covering membrane housing outlet port

Ensure that the anti-telescoping device (ATD) is located properly on the membrane.

Excessive pressure drop [exceeding max ∆P] (high primary pressure – low final pressure)

Severely fouled or dirty membranes Clean the membranes.

Water flowing when machine is turned off

Inlet control valve not closing or seating properly.

Clean or replace the solenoid valve. Clean the membranes immediately. Water must not pass through the inlet when the machine is off.

Repair or replace valve components as necessary.

Declining rejection (high permeate conductivity)

Dirty or fouled membranes Clean the membranes.

O-ring seal broken or damaged Replace the O-ring, check the sealing surfaces on the O-ring groove, interconnectors and end caps. Replace damaged parts.

NOTE: This typically only happens immediately after membrane installation.

Change in incoming water quality Open the concentrate valve and flush. Test the water for pH, hardness, TDS, and iron content. A water analysis should be sent to GE Water & Process Technologies for review.

Declining rejection (high permeate conductivity)

(continued)

Inaccurate conductivity monitor or fouled probe

Calibrate the monitor with a conductivity standard solution or check the readings with another conductivity meter. Replace or clean the probe. Check the connections between the probe and monitor.

Low recycle flow Adjust recycle flow (if applicable).

Page 49: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

________________________________________________________________________ Rev A MISCELLANEOUS

February 2017 6-1

6 MISCELLANEOUS

6.1 Return Goods Authorization (RGA) Procedure

If you wish to return goods for repair, warranty evaluation and/or credit, please have

your original sales order or invoice available when you call GE Water & Process

Technologies. Call the GE Water & Process Technologies Field Service Group at (8621)

3877 7888. An GE Water & Process Technologies Field Service representative will

provide instructions and a return authorization number, which needs to be clearly

written on the outside of the box used to ship your materials. All equipment must be

shipped to GE Water & Process Technologies with the freight prepaid by the customer.

Call our Customer Support Center with any questions or issues concerning freight claims

and a representative will discuss your situation.

All materials to be returned must be rendered into a non-hazardous condition prior to

shipping.

6.2 Machine Warranty/Guarantee

1. Exclusive Terms and Conditions

Together with any other terms the parties agree to in writing, these Terms and Conditions of Sale form the exclusive terms (“Agreement”) whereby Buyer agrees to purchase, and Seller agrees to sell Goods and provide advice, instruction and other services in connection with the sale of those Goods (“Services”). Notwithstanding any provisions communicated in any way by Buyer to Seller prior to this Agreement including any terms contained in any request for quote by Buyer, Buyer agrees that this Agreement will control the relationship by accepting Goods and Services from Seller, even if Buyer sends to Seller other terms and conditions to which Seller may not respond.

2. Buyer Obligations

Seller will not control the actual operation of either Buyer’s systems or Goods at the site, and unless otherwise specifically agreed in writing, installation of Goods shall be the responsibility of Buyer. Goods and Services provided hereunder are based upon the information Buyer makes available to Seller, and Seller reserves the right to utilize the most compact and feasible design compatible with sound engineering practices, and to make changes in details of design, construction and arrangement of Goods unless precluded by limitations (including, but not limited to actual space and feed water/substance quality specifications) specified by Buyer in writing at the time an order is placed. If no such limitations are specified, Seller shall not be held responsible for incompatibility of the Goods and Services due to changes in feed water/substance quality specifications or site conditions nor for incompatibility with actual space or design limitations, which were not initially disclosed by Buyer and become apparent at a later date. For Services to be accurate and Goods to work as intended, Buyer must fulfill the following obligations (“Obligations”): (a) provide Seller complete and accurate information and data relevant to the scope of work to be provided, such as information related to Buyer’s site conditions, systems, related equipment and processes, feed water or other substances to be treated or measured with the Goods , including any hidden, unapparent, or changing conditions that may affect the

Page 50: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

________________________________________________________________________ MISCELLANEOUS Rev A

6-2 February 2017

effectiveness of the Goods; (b) operate all related systems and the Goods within the agreed to control parameters or, if none, within industry customary operating conditions; (c) maintain all related systems and Goods in good operating condition and repair; and (d) maintain and handle Goods in a proper and safe manner. If Buyer’s fails to fulfill the foregoing Obligations, Seller shall be relieved of any obligations with respect to warranties or any other commitments made to Buyer in writing, and Seller shall have no liability for any loss, damage or injury which Buyer may sustain or for which Buyer may be liable.

3. Payment and Prices

Unless otherwise specified in writing, payment is due net thirty (30) days from the date of Seller’s invoice. If Seller shall have any doubt at any time as to Buyer's ability to pay, Seller may decline to make deliveries except on receipt of satisfactory security. The prices quoted herein do not include taxes. Buyer shall be directly responsible, and reimburse Seller, for the gross amount of any present or future sales, use, excise. value-added, or other similar tax applicable to the price, sale of delivery of any products or services furnished hereunder. Buyer shall furnish Seller with evidence of exemption acceptable to the taxing authorities if applicable. [For multi-year agreements, pricing stated shall remain firm for 12 months, after which Seller shall be entitled to adjust pricing upward on an annual basis according to the designated formula used by Seller in Buyer’s country and which shall be notified to Buyer.] Unless otherwise specified, all prices are ExWorks Seller’s facility. Buyer agrees to reimburse Seller for collection costs, including 2% interest per month, should Buyer fail to timely pay. Buyer shall have no rights to any setoffs of any nature relating to any payments due under the Agreement.

4. Payment for Excessive Usage; Lost and Damaged Goods

If payment for Goods is based on some factor other than the actual amount of Goods delivered (e.g., payment is for a fixed amount, or based on usage or production), then Buyer agrees to pay for all Goods (a) consumed as a result of Buyer’s failure to comply with Obligations as set forth in Section 2; or (b) lost or damaged after delivery to Buyer. Buyer shall provide Seller all information necessary to calculate amounts due and enable Seller to audit those records.

5. Deliveries

Unless stated otherwise in the Proposal, Seller shall deliver all products to Buyer EXW Seller’s facility, place of manufacture, or warehouse, according to INCOTERMS 2000. Shipment dates, if applicable, noted in this Proposal represent Seller's best estimate of probable delivery time considering conditions known at the time this Proposal was prepared. Upon acceptance of Buyer’s Purchase Order or, where specified in the Purchase Order, upon receipt of Buyer’s Notification to Proceed with Fabrication of Equipment that satisfies Seller’s requirements for meeting the delivery schedule, Seller shall commence fabrication of equipment. The place of delivery specified therein shall be firm and fixed, provided that Buyer may notify Seller no later than 45 days prior to the scheduled shipment date of the products of an alternate point of delivery. Provided the parties agree a Variation to take into account any additional cost [or delay] incurred by Seller in implementing this change, the alternate place of delivery shall become the agreed place of delivery for all purposes under this Agreement.

6. Consigned Goods

Buyer shall bear all risk of loss and damage to all consigned Goods in Buyer’s possession or control, notwithstanding Buyer’s exercise of reasonable care. Seller shall have the right to enter Buyer’s premises at all reasonable times to inspect such Goods and related records. Upon request, Buyer agrees to return such Goods to Seller pursuant to Seller’s shipping instructions.

7. Limited Warranties

Seller warrants that the Goods shall conform to published specifications and shall be free from defects in material and workmanship when at all times operated in accordance with Seller’s written instructions; and that the Services will be performed with the degree of skill which can reasonably be expected from a seller

Page 51: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

________________________________________________________________________ Rev A MISCELLANEOUS

February 2017 6-3

engaged in a comparable business and providing comparable services under comparable circumstances. Unless otherwise provided in any Warranty Schedule that may be attached hereto, the foregoing warranties are valid: (a) for Chemicals and Services, for 6 months from their date of delivery or the provision of Services; (b) for Consumables, including Filters and Membranes, 12 months from their date of delivery, (c) for Goods other than Chemicals and Consumables, the earlier of, 15 months from receipt, or 12 months from start-up/first use. Unless expressly agreed in a "Performance Warranty Document" signed between the parties on a separate basis, there is no performance warranty on Goods and Services or warranty on process results. For Goods not manufactured by Seller, the warranty shall be the manufacturer’s transferable warranty only. Any claim for breach of these warranties must be promptly notified in writing or the claim will be void. Seller’s sole responsibility and Buyer’s exclusive remedy arising out of or relating to the Goods or Services or any breach of these warranties is limited to, at Seller’s option: (a) replacement of non-conforming Goods or refund of purchase price of the non-conforming Goods; and (b) re-performance of the Services at issue, or a refund of the amount paid for the Services at issue. No allowance will be made for repairs or alterations made by Buyer without Seller's written consent or approval. Goods may not be returned to Seller without Seller's written permission. Seller will provide Buyer with a "Return Material Order" number to use for returned goods. Buyer, as the original purchaser, is not entitled to extend or transfer this warranty to any other party. The foregoing warranties are in lieu of and exclude all other warranties, statutory, express or implied, including any warranty of merchantability or of fitness for a particular purpose.

8. Use of Equipment, Tanks, and Containers

Tanks and SBCs owned by Seller shall be used only for the storage of Goods approved by Seller and, at Seller’s request, shall be returned to Seller within thirty (30) days.

9. Compliance with Laws; Permits

Buyer is responsible for compliance with all laws and regulations applicable to the storage, use, handling, installation, maintenance, removal, registration and labeling of all Goods from and after Buyer’s receipt of the Goods, as well as for the proper management and disposal of all wastes and residues (including containers) resulting from Buyer’s use of the Goods. Buyer agrees to ensure that all Goods and Services provided to Buyer for export are exported only in compliance with applicable export control laws and regulations. Permits and licenses of a permanent nature, or which are required to operate apparatus or equipment or to use the Goods, shall be procured by Buyer at Buyer’s sole expense.

10. Installation

For equipment purchase if applicable, installation costs of the equipment and materials supplied shall be the responsibility of the Buyer, unless otherwise provided within the Seller’s proposal. Otherwise, unless stipulated in the Seller’s proposal, Buyer agrees to pay for start-up supervision and operator instruction, at the Seller's prevailing rate per day. Buyer also agrees to pay reasonable expenses for transportation room and board for Seller's personnel. Standard terms of sale include two sets of operating instructions. If additional sets are required, they are available at an additional charge. Upon receipt of request for additional sets, a price quotation will be forwarded.

11. Differing Site Conditions And Hazardous Materials

In the event that Seller encounters any Hazardous Materials (shall mean toxic substances, hazardous substances, pollutants, contaminants, regulated wastes, or hazardous wastes as such terms may be defined or classified in any law, statue, directive, ordinance or regulations promulgated by any applicable governmental entity) at the Buyer’s site, other than Hazardous Materials introduced by Seller or that are otherwise the express responsibility of Seller under this Agreement, Buyer shall immediately take whatever precautions are required to legally eliminate such hazardous conditions so that the Seller’s work under this Agreement may safely proceed.

12. Emergencies

Page 52: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

________________________________________________________________________ MISCELLANEOUS Rev A

6-4 February 2017

In the event an emergency condition should occur where the protection of either the plant equipment, employees at site, or the surrounding community are threatened, Seller may procure the required and necessary equipment, personnel, or subcontract support. Seller must provide immediate notice to Buyer regarding the emergency and then provide a report after reviewing the events and itemizing all expenditures. Buyer will reimburse Seller for all emergency related expenses.

13. Excusable Delay/Non-Performance

Seller shall not be liable nor in breach or default of its obligations under this Agreement to the extent performance of such obligations is delayed or prevented, directly or indirectly, due to causes beyond the reasonable control of Seller, including, but not limited to: acts of God, fire, terrorism, war (declared or undeclared) epidemics, material shortages, insurrection, act (or omissions) of Buyer or Buyer’s suppliers or agents, any act (or omission) by any governmental authority, strikes, labor disputes, transportation shortages, or vendor non-performance. The delivery or performance date shall be extended for a period equal to the time lost by reason of delay or non-performance, plus such additional time as may be necessary to overcome the effect of the delay or non-performance. If Seller is delayed by any acts (or omissions) of Buyer, or by the prerequisite work of Buyer’s other contractors or suppliers, Seller shall be entitled to an equitable price and performance adjustment as applicable.

14. Confidentiality and Intellectual Property

Both parties agree to keep confidential the other party’s proprietary non-public information, if any, which may be acquired in connection with this Agreement. Buyer will not, without Seller’s advance written consent, subject Goods to testing, analysis, or any type of reverse engineering. Seller retains all intellectual property rights including copyright which it has in all drawings and data or other deliverables supplied or developed under this Agreement, subject to Buyer’s right to use such drawings and data for its own use without additional cost. Buyer acknowledges that Seller is in the business of selling the Goods subject to this Agreement and agrees that it will not file patent applications on the Goods, or processes and methods of using the Goods, without Sellers express written permission. Buyer further agrees that in any event any such patents will not be asserted against Seller or its customers based upon purchase and use of such Goods. Buyer shall be fully liable for any infringement of patent rights of third parties arising out of the products supplied hereunder where the construction, and other characteristics of such products including modification of the Goods and Services, is prescribed to the Seller, or completed independently, by the Buyer or agent(s). Buyer shall fully defend and indemnify the Seller in case of such claim(s). Any software Seller owns and provides pursuant to this Agreement shall remain Seller’s property. Seller provides to Buyer a limited, non-exclusive and terminable license to such software for the term of this Agreement. Buyer agrees not to copy, sub-license, translate, transfer, reverse engineer, or decode the software. Unless otherwise expressly agreed by Seller, this license shall terminate and the software shall be returned to Seller upon termination of this Agreement, or the material breach of the terms in this section.

15. Limitation on Liability

To the extent permitted by law, the total liability of the Seller for all claims arising out of or relating to the performance or breach of this Agreement or use of any Goods or Services shall not exceed the annual contract value of this Agreement. Seller shall not be liable for any advice, instruction, assistance or any services that are not required under this Agreement or for which Seller does not charge Buyer. In no event will either party be liable to the other for lost profits or revenues, cost of capital or replacement or increased operating costs, lost or decreased production, claims of Buyer’s customers for such damages or any similar or comparable damages, or for any incidental, special, consequential or indirect damages of any type or kind, irrespective of whether arising from actual or alleged breach of warranty, indemnification, product liability or strict liability, or any other legal theory. If Buyer is supplying Seller’s Goods or Services to a third party, Buyer shall require the third party to agree to be bound by this clause. If Buyer does not obtain this agreement for Seller’s benefit

Page 53: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

________________________________________________________________________ Rev A MISCELLANEOUS

February 2017 6-5

for any reason, Buyer shall indemnify and hold Seller harmless from all liability arising out of claims made by the third party in excess of the limitations and exclusion of this clause.

16. Conflicts; Survival, Assignment

If there is any conflict between this Agreement and any written proposal or quotation provided by Seller, then the terms and conditions set forth in the proposal or quotation shall prevail. If any term or condition of this Agreement or any accompanying terms and conditions are held invalid or illegal, then such terms and conditions shall be reformed to be made legal or valid, or deleted, but the remaining terms and conditions shall remain in full force and effect, and the Agreement shall be interpreted and implemented in a manner which best fulfills our intended agreement. This Agreement may only be assigned by Seller to any affiliate.

17. Termination and Cancellation

This Agreement and any performance pursuant to it may be terminated or suspended by either party if the other party (a) is the subject of bankruptcy or insolvency proceedings; or (b) defaults in its material obligations under this Agreement, and such default is not cured within thirty (30) days. Upon the termination of this Agreement: (a) Buyer agrees to pay for all Goods in Buyer’s possession or for which title has passed to Buyer, at current prices or at such other prices as have been agreed to in writing; and (b) all amounts owing, if any, for the equipment or tanks relating to those Goods shall immediately become due and shall be paid within thirty (30) days of receipt of an invoice. In the event of cancellation of an order by Buyer, a cancellation charge will be made against the Buyer, in proportion to the work completed by Seller, or obligated against the order, plus any cancellation charges assessed against Seller by Seller’s suppliers.

18. Governing Law and Dispute Resolution

This Agreement shall be governed by the substantive laws of the State of New York. The UN Convention on the International Sale of Goods shall not apply. In the event of a dispute concerning this Agreement, the complaining party shall notify the other party in writing thereof. Management level representatives of both parties shall meet at an agreed location to attempt to resolve the dispute in good faith. Should the dispute not be resolved within thirty (30) days after such notice, the complaining party shall seek remedies exclusively through arbitration. The seat of arbitration shall be the federal district court in Atlanta, GA, and the rules of the arbitration will be the Commercial Arbitration Rules of the American Arbitration Association, which are incorporated by reference into this clause.

6.3 Membrane Element Warranty/Guarantee

Limited Warranty Covered membrane elements: OSMO PRO Series GE Osmonics, Inc. (hereinafter “Seller“) gives a warranty on materials, workmanship and performance of its spiral wound membrane elements listed above (hereinafter “Elements”) when used in accordance with Seller’s recommended design and operating instructions.

Initial Performances The Seller warrants to the original buyer that the Elements shall have initial performance as defined in the specification sheet for the Elements.

Full Replacement Period The Seller guarantees for 12 months from the date of shipment from a GE Osmonics facility the Elements to be free from defects in material or workmanship that affect the performance of the Elements, for 12 months from the date of shipment from a GE Osmonics facility.

Prorated Replacement Period The Seller gives a 36 months prorated performance warranty for its Elements starting at the date specified in Section ”Start of Warranty Period”. During the pro-rated period, the Seller guarantees that when operated within the Operation and Storage Conditions stated in this Warranty under standard test conditions (see the element specification sheet) and after an appropriate

Page 54: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

________________________________________________________________________ MISCELLANEOUS Rev A

6-6 February 2017

cleaning cycle, the permeate flow rate of the Elements shall be at least 70 percent of the minimum value stated on the specification sheet and the salt passage shall not exceed 2 times the maximum value stated on the specification sheet.

Start of Prorated Period The Warranty period starts at the date on the following list that occurs first: • Operation of the Elements in a membrane system • 3 months from the Elements ship date from the Seller’s manufacturing facility to a location in North America. In this document, North America includes Canada, United States, Mexico and the Caribbean islands • 6 months from the Elements ship date from the Seller’s manufacturing facility to a location outside North America.

Storage Conditions This Warranty is strictly subject to the following Storage Conditions and is void if they are not met. The Elements shall be stored at a temperature never exceeding the maximum operating temperature that is stated in the specification sheet of the specific element. The Elements shall not be exposed to direct sunlight for more than a few minutes that might be required when transferring the Elements from one site to another. Before first use, the Elements shall be store in their original plastic bags.

Operating Conditions This Warranty is strictly subject to the following Operating Conditions and is void if they are not met. The feed water to the Elements should be free of oil, grease, colloidal, particulate matter or biological growth. b) The feed water to the Elements should be free of ozone, permanganate, hexavalent chromium, free chlorine, hypochlorous acid, hypochlorite and other oxidizing agents harmful to the Elements. c) The operating conditions, e.g. temperature, pressure, pH, Feed SDI15 and Turbidity shall not be outside the range described in the specification sheets of the Elements. d) The Elements shall be maintained in good, clean condition. When the normalized permeate flow rate of the Elements have declined by 10%, the Elements must be cleaned using a to Seller’s accepted cleaning procedure. e) The membrane system design shall be consistent with sound engineering practice, and the Elements shall not at any time be exposed to water hammer or permeate backpressure. Permeate backpressure is here defined as a positive value of the permeate static pressure minus the concentrate static f) The operating parameters and system performance of the membrane systems where the Elements are used shall be routinely 1) recorded, 2) normalized, 3) reviewed and 4) filed in an orderly format. Operating parameters shall include, at a minimum, feed stream temperature and pH, feed stream and operating pressures, dates, durations and chemicals used of system cleaning. g) In the event of an Element warranty claim, the collected data in section f) above shall be made available to the Seller upon request. Upon request, the Buyer shall allow people representing the Seller to visit and examine the equipment and operating procedures where the Elements under the warranty claim are or were used.

Warranty Claim Procedure The Buyer completes a Returned Goods Authorization (RGA) form (obtained from the Seller’s Quality Assurance department) and sends it freight prepaid to the Seller’s Quality Assurance department. The Seller has the option of making inspections and tests of the alleged defective Elements and the membrane system where these are or were used, or requesting Buyer to perform such inspections or tests and forward the results thereof to Seller, or requesting the Buyer to return all or some of the Elements under warranty claim to the Seller. If during inspection at the membrane system, the Element failure is determined to be from a cause other than breach of Warranty as set forth above, Buyer shall pay to Seller a fee of US$ 500.00 per day plus all direct expenses incurred by Seller’s representatives in connection with any inspection and testing of such Elements and the membrane system. If the Buyer is requested to return Elements to the Seller, the Buyer receives an RGA number and instructions how to ship the Elements (prepaid with the proper shipping documents, which includes the RGA number). If the Seller determines that the returned Elements perform as warranted, the Elements will be returned to the Buyer freight collect, and a charge of $100.00 per element will be levied against the Buyer. The Elements perform as warranted if the average performance of the returned Elements is at or better than the warranted performance.

Repairs and Replacement The Seller’s obligation for discharging this warranty and Buyer's sole remedy for any breach is limited to and shall be fully discharged by the Seller, at Seller’s sole discretion, repairing or replacing the defective Elements at the exworks membrane price current at the time of replacement, less a rebate. The rebate is 100% under the Material and Workmanship warranty, and prorated on the unrealized warranty period (1/36 per month) under the Prorated Performance Warranty. The repaired or replaced elements under the prorated warranty will be shipped to the Buyer prepaid, and carry the same Three-Year Prorated Membrane Element

Page 55: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

PRO AP Series

________________________________________________________________________

________________________________________________________________________ Rev A MISCELLANEOUS

February 2017 6-7

Performance Limited Warranty as did the Elements they replaced, starting from the date specified in Section ”Start of Warranty Period”, where the dates refer to the dates for the repaired or replaced elements. The Seller’s total liability shall not exceed the replacement value of the Elements that do not meet the guaranteed performance.

DISCLAIMER AND LIMITATION ON LIABILITY THIS WARRANTY IS IN LIEU OF AND EXCLUDE ALL OTHER WARRANTIES, WRITTEN OR ORAL, STATUTORY, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND THESE REMEDIES ARE THE SOLE REMEDIES WITH RESPECT TO THE WARRANTY. IN NO EVENT WILL SELLER BE LIABLE FOR INCIDENTAL, SPECIAL OR CONSEQUENTIAL, INDIRECT, EXEMPLARY OR PUNITIVE DAMAGES ARISING FROM THE GOODS OR SERVICES, IRRESPECTIVE OF WHETHER THE CLAIM RISES FROM ACTUAL OR ALLEGED BREACH OF WARRANTY, INDEMNIFICATION, BREACH OF CONTRACT, PRODUCT LIABILITY, CONTRIBUTION OR ANY LEGAL THEORY AND IN NO EVENT WILL SELLER BE LIABLE FOR LOST PROFITS, COSTS OR LOSSES NOT ASSOCIATED WITH DIRECT PHYSICAL DAMAGE TO PROPERTY.

ASSIGNMENT This Warranty may not be assigned or otherwise transferred by Buyer without the prior written consent of Seller.

6.4 Start-Up Data

Customer: Date: Model No: Tested By: Pump Model No: Serial No:

Units (Circle One) Data Data Remarks

Temperature F C

Permeate Rate gpm lpm / /

Concentrate Rate gpm lpm / /

Total Flow Rate gpm lpm / /

% Recovery %

Pre-Filter Pressure psi bar

Post-Filter Pressure psi bar

Primary Pressure psi bar

Final Pressure psi bar

Feed Conductivity S/cm

Concentrate Conductivity S/cm

Average Conductivity S/cm

Page 56: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual PRO AP Series

________________________________________________________________________

________________________________________________________________________ MISCELLANEOUS Rev A

6-8 February 2017

Customer: Date: Model No: Tested By: Pump Model No: Serial No:

Units (Circle One) Data Data Remarks

Permeate Conductivity (manual)

S/cm

Permeate Conductivity (meter) S/cm

% Passage (Perm TDS/Avg TDS)

%

Chlorine in Concentrate Ppm

Low Pressure Switch Setting psi bar

Page 57: Operation & Maintenance Manual - PRO AP Series RO …osmonicsrosystem.com/.../pdf/...ro-operations-maintenance-manual.pdf · OPERATION AND MAINTENANCE MANUAL ... Prepared For: Client

Client Name Operation and Maintenance Manual

XXXXXX PRO AP Series

____________________________________________________________________________________________________________

____________________________________________________________________________________________________________ Rev A MISCELLANEOUS

February 2017 6-9

6.5 Daily Log Sheet

NOMENCLATURE: PRESS = PRESSURE CONC = CONCENTRATE, QC PERMEATE = PERMEATE, QP TEMP = TEMPERATURE COND = CONDUCTIVITY

MACHINE MODEL NO: NAME OF COMPANY:

SERIAL NO: PERIOD OF THIS SHEET:

NOTE: Please record all calibrations of instruments or other occurrences related to this system.

DATE AND TIME

PRE-FILTER PRESSURE (psi or bar)

POST-FILTER PRESSURE (psi or bar)

PRIMARY PRESSURE (psi or bar)

FINAL PRESSURE (psi or bar)

FEEDWATER TEMP (F or C)

PERM FLOW (gpm or lpm)

CONCENTRATE FLOW (gpm or lpm)

RECOVERY, QP / (QP+QC)

FEED COND (S)

CONC COND (S)

PERM COND (S)

AVERAGE COND (S), (CF+CC)/2

FILTER CHANGE ()

CLEAN ()

FEED CHLORINE (ppm)

FEEDWATER HARDNESS (ppm)

OPERATORS INITIALS

Reference the Troubleshooting Guide where trends or differences are noted. This is a template; make copies as necessary.