Operation Manual2 SELFJECTOR Instruction Manual Operation Manual 2 Precautions for safety Functions of components Operation setting items and adjustment procedures How to start and stop SAMGONG-MITSUBISHI SELFJECTOR GENIUS-SERIES Instruction Manual

Upload: spiritshunter

Post on 11-Dec-2015

370 views

Category:

Documents


102 download

DESCRIPTION

INSTRUCTION MANUAL - SAMGONG MITSHUBISHI SELFJECTOR GENIUS - SERIES. PRECAUTIONS FOR SAFETY, FUNCTIONS OF COMPONENTS, OPERATION SETTING ITEMS AND ADJUSTMENT PROCEDURES, HOW TO START AND STOP

TRANSCRIPT

Page 1: Operation Manual 2-Samgong

Operation Manual2 SELFJECTOR Instruction Manual

Operation Manual 2 Precautions for safety

Functions of components

Operation setting items and

adjustment procedures

How to start and stop

SAMGONG-MITSUBISHI

SELFJECTORGENIUS-SERIES

InstructionManual

Page 2: Operation Manual 2-Samgong
Page 3: Operation Manual 2-Samgong

IMPORTANCE

The manual is edited for treating mineral oils

such as for purifying fuel oil or lubricating oil.

Page 4: Operation Manual 2-Samgong
Page 5: Operation Manual 2-Samgong

! WARNING

The instruction manual is a guidebook for using the automatic discharge type oil

purifier, SAMGONG-MITSUBISHI SELFJECTOR GENIUS SERIES (hereinafter as

referred to as SELFJECTOR).

SELFJECTOR is a fast rotating centrifugal machine. Before using it, sufficiently be

versed in details of the manual.

Handle it safely and so as to fully exhibit the function of SELFJECTOR.

The composition of instruction manual for SELFJECTOR is as follows.

The present manual is Part 3 "Operation manual2".

Use each manual according to the particular purpose to sufficiently

understand the information.

Page 6: Operation Manual 2-Samgong

①: Design Engineer ②: Installer ③: Engine Engineer ④: OperatorIntended

ReaderManual Description ① ② ③ ④1 Outline of fitting-out aboard Information for transportation, handling and storage of the

machine

Instructions for installation and dimensions

System diagram and connection diagram

O O

2 Operation Manual 1 Precautions for safety

Configuration and construction of SELFJECTOR

Motor, starter, automatic control panel

Multi-Monitor

O

3 Operation Manual 2 Precautions for safety

Functions of components

Operation setting items and adjustment procedures

How to start and stop

O

Operation Manual 3 Precautions for safety

Function, operation and maintenance information on

automatic control panel GBC-1 & GSH-1

O

4

5 Maintenance Manual Precautions for safety

Disassembly and reassembly procedures

Maintenance and inspection procedures

Troubleshooting and corrective action

O

NOTEThe Part 4 manuals (Operation Manuals 3) deal with the following types of the automatic control

systems. When you purchase the SELFJECTOR controlled by one of these control systems, the

associated operation manual of Part 4 will be supplied.

Automatic control systems: GBC-1 and GSH-1

Page 7: Operation Manual 2-Samgong

Contents (1 / 3)

1 Precautions in safety ............................................................................................ 1-1

1.1 Symbols related to safety .......................................................................................................... 1-1

1.2 Labels for safety........................................................................................................................ 1-2

1.3 Safety precautions .................................................................................................................... 1-3

1.4 Definition of terms ..................................................................................................................... 1-5

2 Component Functions of the Purifying System.................................................. 2-1

2.1 Automatic control panel............................................................................................................. 2-1

2.2 Multi-Monitor (MM) .................................................................................................................... 2-2

2.2.1 Display Function........................................................................................................................ 2-3

2.2.2 Leakage Monitor Function (LM) ................................................................................................ 2-3

2.2.3 Discharge Detector (DD) ........................................................................................................... 2-3

2.2.4 Water Detector Function (WD) .................................................................................................. 2-3

2.3 Gear pump ................................................................................................................................ 2-5

2.4 Safety joint ................................................................................................................................ 2-5

2.5 Plug (sludge outlet) ................................................................................................................... 2-5

2.6 Operating water solenoid valves unit......................................................................................... 2-6

2.7 3-way Cylinder Valve................................................................................................................. 2-6

2.8 3-way Solenoid Valve................................................................................................................ 2-6

2.9 Oil Heater .................................................................................................................................. 2-6

2.10 Oil strainer................................................................................................................................. 2-6

2.11 Flow control valve ..................................................................................................................... 2-6

2.12 Pressure Control Valve (needle valve) ...................................................................................... 2-6

3 Setup Items and Recommended Values for Operation ...................................... 3-1

3.1 Feed Rate ................................................................................................................................. 3-1

3.2 Treating Temperature................................................................................................................ 3-2

3.3 Gravity Disc............................................................................................................................... 3-3

3.3.1 Supplied gravity discs................................................................................................................ 3-3

3.3.2 Gravity disc selection procedure ............................................................................................... 3-5

3.4 Lubrication Oil ......................................................................................................................... 3-35

3.4.1 Oil quantity .............................................................................................................................. 3-35

3.4.2 Optimum viscosity ................................................................................................................... 3-36

3.4.3 Recommended brands ............................................................................................................ 3-37

3.5 Sludge Discharge Interval ....................................................................................................... 3-38

3.5.1 Discharge Interval (Total discharge)........................................................................................ 3-38

3.5.2 Discharge Interval (HIDENS specification).............................................................................. 3-39

Page 8: Operation Manual 2-Samgong

Contents (2 / 3)

3.6 Operating Water ...................................................................................................................... 3-41

3.6.1 Operating water quality ........................................................................................................... 3-42

3.6.2 Setting pressure of operating water ........................................................................................ 3-42

3.6.3 Operating water for opening bowl............................................................................................ 3-44

3.6.4 Operating water for closing bowl ............................................................................................. 3-44

3.6.5 Quantity of sealing water/regulating water and replacement water, washing water ................ 3-45

3.6.6 Quantities of washing water .................................................................................................... 3-46

3.7 Partial Discharge Setting/Adjustment (GSH-1)........................................................................ 3-47

3.7.1 Setting/adjustment of partial discharge ................................................................................... 3-47

3.7.2 Measure of the amount of partial discharge ............................................................................ 3-48

3.8 Timer Setup on the Automatic Control Panel .......................................................................... 3-51

3.8.1 GBC-1 type timer settings(guideline) ...................................................................................... 3-51

3.8.2 GSH-1 type timer settings (guideline)...................................................................................... 3-53

4 Multi-Monitor.......................................................................................................... 4-1

4.1 Multi-Monitor ............................................................................................................................. 4-1

4.1.1 Kinds of switches and Setting parameters ................................................................................ 4-1

4.1.2 Accessing Memory Preset Items and Changing Memory Settings............................................ 4-3

4.1.3 Wiring ........................................................................................................................................ 4-5

4.2 Leakage Monitor Function (LM) ................................................................................................ 4-7

4.2.1 Setting Up the Leakage Monitor Function ................................................................................. 4-7

4.2.2 Principal Preset Items ............................................................................................................... 4-8

4.2.3 Light Liquid Outlet Pressure Adjustment ................................................................................... 4-9

4.2.4 Checking Timer Setting after Start of Feeding ........................................................................ 4-10

4.2.5 Pressure Adjustment after Feeding......................................................................................... 4-10

4.3 Discharge Detector Function (DD) .......................................................................................... 4-11

4.3.1 Setting Up the Discharge Detector Function ........................................................................... 4-11

4.3.2 Adjusting the Proximity Switch Position .................................................................................. 4-12

4.3.3 Checking Proximity Switch Position ........................................................................................ 4-13

4.4 Water Detector Function (WD) ................................................................................................ 4-14

4.4.1 Setting Up the Water Detector Function.................................................................................. 4-14

4.4.2 Principal Preset Items ............................................................................................................. 4-15

4.4.3 Adjusting Circulation Line Back Pressure Valve...................................................................... 4-15

4.4.4 Setting Up the Electrostatic Capacity Type Water Detector .................................................... 4-16

Page 9: Operation Manual 2-Samgong

Contents (3 / 3)

5 Operation ............................................................................................................... 5-1

5.1 Inspections Prior to Running ..................................................................................................... 5-1

5.1.1 Pipe connections....................................................................................................................... 5-1

5.1.2 Electrical wiring ......................................................................................................................... 5-1

5.1.3 Flushing..................................................................................................................................... 5-1

5.1.4 Inspections prior to running (confirmation) ................................................................................ 5-2

5.2 Start-Up..................................................................................................................................... 5-4

5.2.1 Precautions on start-up ............................................................................................................. 5-4

5.3 Stop........................................................................................................................................... 5-4

5.3.1 Precautions on stop .................................................................................................................. 5-4

5.4 Automatic Specification (GBC-1, GBC-2).................................................................................. 5-5

5.4.1 Start-up ..................................................................................................................................... 5-6

5.4.2 Stop........................................................................................................................................... 5-8

5.5 Automatic Specification (GSH-1)............................................................................................... 5-9

5.5.1 Start-up ................................................................................................................................... 5-10

5.5.2 Stop......................................................................................................................................... 5-13

5.6 Manual Specification (GAP-11) ............................................................................................... 5-14

5.6.1 Start-up ................................................................................................................................... 5-15

5.6.2 Stop......................................................................................................................................... 5-19

5.7 Manual Specification ............................................................................................................... 5-21

5.7.1 Start-up ................................................................................................................................... 5-22

5.7.2 Stop......................................................................................................................................... 5-26

6 Suspension ............................................................................................................ 6-1

6.1 Preparations for Suspension ..................................................................................................... 6-1

6.2 Maintenance during Suspension ............................................................................................... 6-2

6.2.1 Purifier main body and mechanical components....................................................................... 6-2

6.2.2 Electrical component ................................................................................................................. 6-2

6.3 Resuming Operation ................................................................................................................. 6-2

6.4 Other ......................................................................................................................................... 6-2

Page 10: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual21-1

1 Precautions in safety

For correct use, carefully read the "Precautions in safety" beforehand.

Precautions in safety given in the instruction manual are intended for safely and correctly using the

product and avoiding danger or damage to user. Carefully read the precautions and do not operate,

maintain or handle SELFJECTOR before you are fully versed in them.

1.1 Symbols related to safety

In the manual, precautions are headed by the following marks. Be sure to observe them because they

are important for ensuring the safety.

! WARNING: indicates a potentially hazardous situation which ,if not heeded, could result

in death or serious injury.

! CAUTION: indicates a hazardous situation which ,if not heeded ,may result in minor or

moderate injury or damage to the purifier or facilities.

NOTE: indicate precautionary instructions that given contain what must be done

without fail and what should be kept in mind as a guide in operating

SELFJECTOR and doing related work.

Page 11: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual21-2

1.2 Labels for safety

There are 3 different labels for safety.

The one shown in Pic. 1 is put in the spare part box. After fitting-out aboard, the person in charge of

installation is requested to attach it on an easily visible place near SELFJECTOR.

Pic. 2, Pic. 3 are factory attached direct on SELFJECTOR. Do not smear them by painting but keep

them visible at all times.

Safety labels are available any time. Request them as required.

Pic. 1

Pic. 2 Pic. 3

안전의주의사항경고

Page 12: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual21-3

1.3 Safety precautions

! WARNING

The bowl of SELFJECTOR produces a large centrifugal force when it rotates. Wrong handling is very

dangerous. Pay utmost attention according to the manual for operation, disassembly, reassembly,

maintenance, checkup, etc. Use of non-genuine parts might damage SELFJECTOR or impair human

safety. Be sure to employ genuine parts.

Perfectly assemble.

Many points of SELFJECTOR are connected by screws. When assembling, make sure tightening is

complete. Running with poor tightening is very dangerous. Doubly make sure of secure tightening

particularly of:

(A) Bowl nut

(B) Disc nut

(C) Cap nut of Vertical shaft

(D) Set bolt of Frame cover

(E) Lock nut (hexagon) of Inlet pipe

Be sure that tally marks of the bowl and other so marked parts are aligned.

If the tally mark is excessively mis-aligned when the Bowl nut is tightened, contact our company or

service agency.

Immediately stop if vibration is excessive.

Vibration of SELFJECTOR is caused by unbalance, ship oscillation,

SELFJECTOR installation, etc. If the vibration is excessive, immediately

stop SELFJECTOR without discharging sludge.

Then, check for the cause and take necessary corrective action to ensure

safety before restarting SELFJECTOR.

To be more specific, if the vibration at the point A of Fig. 1-1 exceeds

100 μm (peak to peak) at rated speed, stop SELFJECTOR.

Even if readings are below 100 μm, continuous cruising ship vibrations

4-5 times higher than registered when external vibrating forces are small,

such as when the main engine is not in operation, could adversely affect

the durability of SELFJECTOR. In such case, stop SELFJECTOR

immediately. Then, check for the cause and take necessary corrective

action to ensure safety before restarting SELFJECTOR as described

above.

Fig. 1-1

Page 13: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual21-4

! WARNING

Make sure of complete stoppage before loosening each section.

Make sure the bowl has complete stopped rotating before loosening or disassembling each section.

Whether completely stopped or not can be checked at the motor fan or Gear pump and Horizontal shaft

connecting section (Safety joint).

Take care in handling the parts.

SELFJECTOR is a precision machine. Handle it attentively away from impact and high temperature.

Particularly never heat the bowl parts (Bowl body, Bowl hood, etc.) by open flame nor weld them.

Beware of corrosion and erosion.

Periodically check whether any damage is produced by corrosion or erosion.

For details, contact our company or service agency.

Others

1. Before disassembling, turn off the starter.

2. Before treating a treating liquid other than specified initially, contact our company or service

agency.

3. The bowl is factory balanced. Never interchange bowl parts Disc (1) even within the same model.

For ambiguous points in the instruction manual, contact our company or

service agency.

Page 14: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual21-5

1.4 Definition of terms

Density (ρ): Mass per unit volume.

Specific gravity (γ): Ratio of mass to mass of

water of the same volume. Varies with

temperature.

Oil feed rate: Volume per unit time of untreated

liquid upstream the purifier expressed in terms of

L/h or m3/h.

Actual capacity: Purifier treating capacity based

on SM Standard (eliminating sludge with 1.8 of

specific gravity and 2μm of diameter or more).

(See "Feed rate" above.)

Feed liquid: Untreated oil to feed to purifier.

Light liquid: Oil treated by purifier or purified oil.

Heavy liquid: Separated moisture and heavy

components in oil or simply "water".

Sludge: Solids accumulated in bowl in narrow

sense. Mixture of solids, water and oil discharged

from bowl in wide sense.

Interface: Boundary surface between heavy and

light liquids in bowl.

Purifier operation (purifying operation):

Operation of separating into 3 phases or liquid,

liquid and solid or, here, into oil, water and solids.

(See "Purifier operation".)

Clarifier operation (clarifying operation):

Operation of separating into 2 phases or liquid

and solid or, here, into oil and solids.

(See "Clarifier operation".)

Parallel operation:

Operation with oil fed proportionally to several

purifiers arranged in parallel.

(See "Parallel operation".)

Series operation:

Operation by several purifiers arranged in series.

(See "Series operation".)

Total discharge type

Purifier designed to totally discharge all

contained in the bowl.

Partial discharge type

Purifier designed to partially discharge water and

solids only in the bowl. This type has the total

discharge function as well.

Abbreviations and units

L: Liter: Unit of volume.

h: Hour(s): Unit of time.

min-1: Number of revolutions per minute.

Hz: Number of frequency.

(cycles per second)

: Unit of diameter in mm.

mm2/S: unit of kinetic viscosity of oil. (= cSt)

ISO: Standards established by International

Standardization Organization.

VG: Indication of viscosity of lubricating oil in

accordance with ISO.

Page 15: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual22-1

2 Component Functions of the Purifying System

2.1 Automatic control panel

Automatic start : (AUTO START)

Each automatic control panel has an "AUTO. START" push button. Pressing this push button after the

purifier has reached its rated speed starts the predetermined sequence of automatic running.

Automatic stop : (AUTO STOP)

Each automatic control panel has an "AUTO. STOP" push button is incorporated in each of the

automatic control panels. Pressing this push button during running switches the feed valve to the

bypass line. The sequence of water replacement and sludge discharge follows, then the automatic

running circuit is cut off and the oil purifier motor is stopped.

Emergency stop : (EM'CY STOP)

Each automatic control panel has an "EM'CY STOP" push button. Pressing this push button during

running cuts off the automatic running circuit immediately and switches the feed valve to the bypass line,

then the oil purifier motor is stopped without sludge discharging.

Discharge test : (DIS-T)

Each automatic control panel has a "DIS-T" push button. When the oil purifier is in automatic

running and in the feeding, pressing this push button forces the discharge interval timer to be timed up,

sludge is discharged.

Page 16: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual22-2

2.2 Multi-Monitor (MM)

The Multi-Monitor forms an integrated detection system with the following digital displays and detectors.

The Multi-Monitor is available in three types (MM-1, MM-2 and MM-3) for selective use according to the

automatic system configuration.

Digital displays Function (Flow rate, temperature, pressure, rotation number*1 and other LED)

: MM-1, MM-2, MM-3

Leakage Monitor Function (LM) : MM-1, MM-2 and MM3

Discharge Detector Function (DD) : MM-2, MM-3

Water Detector Function (WD) : MM-3

NOTE1: MM-1 has no rotation number display function.

Page 17: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual22-3

2.2.1 Display Function

Data necessary for daily monitoring of operational status are digitally indicated through seven

segment LEDs.

Indicated data pertain to flow rate, temperature, pressure, rotation number, circulation line pressure

(G-HIDENS spec.), though those vary with different models of the Multi-Monitor.

NOTE

Since the flow rate displayed on Multi-Monitor(MM) is the value which converted pressure into

flow rate , please use it as a guideline.

When you always use a gear pump under 30% or less of its rated capacity, we recommend using

the small orifice (option) under 1 rank.

2.2.2 Leakage Monitor Function (LM)

The Leakage Monitor is a protective device that detects the treated oil leaking from the sludge

outlet or heavy liquid outlet of the SELFJECTOR by means of a pressure sensor, thereby

minimizing the loss of treated oil.

The pressure sensor is installed on the SELFJECTOR bracket (at the light liquid outlet) and

constantly monitors pressure during feeding. When a pressure drop occurs due to a leakage, the

pressure sensor detects it and the pressure sensor output is sent as a "Leakage" signal to the

automatic control panel via the Multi-Monitor.

2.2.3 Discharge Detector (DD)

The Discharge Detector is a protective device that monitors sludge discharge from the

SELFJECTOR and detects a discharge failure as the "No-discharge" status.

Normal sludge discharge is accompanied by a drop in horizontal shaft rotation speed to the preset

level. Relying on this characteristic, the Discharge Detector constantly monitors the horizontal shaft

rotation speed by means of a proximity sensor. If the horizontal shaft rotation speed fails to fall at

sludge discharge, a "No-discharge" signal is delivered to the automatic control panel via the

Multi-Monitor.

As a self-diagnosis function, "No-discharge" LED (red) is illuminated in response to a shaft rotation

number beyond 2500 rpm or an instable proximity switch input signal.

In addition to the sludge discharge monitoring function, the automatic GSH-1 system combined

with Multi-Monitor MM-3 has a partial discharge detection function to indicate whether or not sludge

discharge is optimal for partial discharge adjustment.

2.2.4 Water Detector Function (WD)

The Water Detector is an integral device that is used for the G-HIDENS system (for clarifier

operation) that constantly monitors the changing levels of separated water in the bowl by means of

a pressure sensor installed in the circulation line.

Pressure in the circulation line falls when separated water in the bowl has reached a predetermined

level. The Water Detector in the G-HIDENS system detects this pressure change by means of the

pressure sensor and effects partial discharge or total discharge with sludge, whereby the inside of

the bowl is always maintained in a normal separating condition.

The Water Detector is used only in the automatic GSH-1 system configuration.

Page 18: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual22-4

Fig. 2-2 Sketch Drawing of MM-1 Fig. 2-3 Sketch Drawing of MM-2, MM-3

Page 19: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual22-5

2.3 Gear pump

This is installed on the bearing housing (3) of

the purifier and connected to the horizontal

shaft via a safety joint. It is driven by the motor

of the purifier. (Refer to Fig. 2-4)

The gear pump supplies feed liquid to the

purifier.

The gear pump can be selected according to

its treating capacity.

Table 2-1 Gear pump capacities (use for suction pump)*1

Model GP10G GP20G GP30G GP50G GP70G GP100G

Capacity(L / h) 1,300 2,100 3,600 5,700 8,200 11,600

Suction head : -4m / Delivery head : 20m

NOTE1:In case of 60Hz

2.4 Safety joint

This is mounted on the end of the horizontal shaft for transmitting the motor power to the pump.

(Refer to Fig. 2-4)

This will be automatically disconnected for protecting the gear pump, if it is subjected to an

excessive overload due to sticking foreign matters, etc.

2.5 Plug (sludge outlet)

! WARNING

Do not open this plug absolutely during a sludge discharge process.

These are inserted in the sludge chute of the purifier main body. (Refer to Fig. 2-4)

When it becomes necessary to check the internal state of the frame, unplugged.

Fig. 2-4

R(

Page 20: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual22-6

2.6 Operating water solenoid valves unit

There are a triple solenoid valves unit for total discharge and a quadruple solenoid valves unit for

both total and partial discharge available for control of operating water. Each unit has a reducing

valve upstream of the solenoid valves. (Refer to Fig. 2-5)

The solenoid valves unit for operating water is built in the oil purifier.

The solenoid valves unit controls the feed of operating water for opening bowl, operating water for

closing bowl, sealing water and replacement water.

Each solenoid valves is actuated by input signals from the automatic control panel to effect and

stop the feed of operating water to the oil purifier.

2.7 3-way Cylinder Valve

This is a pneumatically operated cross valve mounted on the purifier inlet pipe. (Refer to Fig. 2-5)

It supplies feed liquid to the purifier.

When discharging sludge, it returns the oil from the by-lass pipe to the tank by switching the valve

position.

2.8 3-way Solenoid Valve

This is attached on the air piping to the 3-way cylinder valve.(Refer to Fig. 2-5)

The 3-way solenoid valve changes its position according to signals from the control panel and

actuates the 3-way cylinder valve.

2.9 Oil Heater

This is installed on the way between the gear pump and the purifier.(Refer to Fig. 2-5)

It heats the feed liquid supplied from the gear pump to an optimal treating temperature.

There are two types of oil heater; steam type and electric.

2.10 Oil strainer

This is installed upstream of the oil purifier to remove residual solids in the feed liquid. (Refer to Fig.

2-5)

2.11 Flow control valve

This is installed to control the feed rate to the oil purifier. (Refer to Fig. 2-5)

2.12 Pressure Control Valve (needle valve)

This is installed in the light liquid outlet line of the oil purifier. (Refer to Fig. 2-5)

This valve is used to control the light liquid outlet pressure to 0.15 MPa {1.5 kgf/cm2} (standard

value).

NOTE

The light liquid outlet pressure is critical in ensuring that the Leakage Monitor Function (LM) of

the Multi-Monitor acts correctly.

Improper pressure adjustment could result in a LM alarm output. For pressure adjustment

during running, refer to "Leakage Monitor Function (LM)" in the Operation Manual 2.

Page 21: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual22-7

1 SELFJECTOR A Dirty oil inlet

2 Gear pump B Purified oil outlet

3 Solenoid valves unit for operating water C Compressed air inlet

4 3-way cylinder valve (Feed valve) D Sludge & Water outlet

5 3-way solenoid valve E Water inlet

6 Multi-Monitor F Drain

7 Leakage Monitor function (LM) G Circulation

8 Discharge detector function (DD) P Pressure gauge

9 Water detector function (WD) C Compound gauge

10 Oil heater M Motor

11 Oil strainer

12 Flow control valve

13 Pressure control valve (Needle valve)

Fig. 2-5 Typical Purifying System Configuration with Automatic GSH-1 (HIDENS)

Specification of SELFJECTOR

Note) Automatic GBC-1 specificationis not provided with Water Detector (WD)and solenoid valve (SV9).Also, Discharge Detector (DD) is optional

for these specifications.

Page 22: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-1

3 Setup Items and Recommended Values for Operation

3.1 Feed Rate

An appropriate feed rate should be set for operating the SELFJECTOR efficiently.

Table 3-1 shows the actual capacity for each model of the SELFJECTOR G-series.

NOTE

Actual capacity refers to the maximum treating capacity of each model (maximum feed rate).

Table 3-1

Actual capacities (Unit : L/h)

Fuel oil Lubricating oil

A heavy oil C heavy oil Cross-head Trunk-piston

40℃ 98℃ 90℃ 95℃Treating

temperaturemm

2/sec

at 40℃ mm2/sec

at 50℃ Detergent oil

Viscosity 14 180 380 500 600 700 100mm

2/sec

at 40℃ 150mm2/sec

at 40℃2,900 1,600 1,150 890 790 720 1,250 1,050

SJ10G/GH2,900 1,650 1,200 930 830 760 1,350 1,100

4,350 2,450 1,750 1,400 1,250 1,150 1,950 1,650 SJ20G/GH

4,350 2,600 1,850 1,450 1,300 1,200 2,050 1,700

7,800 4,500 3,200 2,550 2,250 2,050 3,550 2,950 SJ30G/GH

7,800 4,700 3,350 2,650 2,350 2,150 3,750 3,100

11,600 6,900 4,900 3,900 3,450 3,150 5,450 4,550 SJ50G/GH

11,600 6,950 4,950 3,950 3,500 3,200 5,500 4,600

13,300 8,000 5,700 4,500 4,000 3,700 6,350 5,300 SJ60G/GH

13,300 8,100 5,750 4,550 4,050 3,700 6,400 5,350

15,900 9,800 6,950 5,500 4,900 4,500 7,750 6,450 SJ70G/GH

15,900 9,750 6,950 5,500 4,900 4,500 7,750 6,400

21,800 14,100 10,000 7,900 7,050 6,450 11,200 9,250 SJ100G/GH

21,800 14,200 10,100 8,000 7,100 6,500 11,300 9,350

24,500 16,300 11,600 9,200 8,150 7,450 13,000 10,700 SJ120G/GH

24,500 16,500 11,700 9,250 8,250 7,550 13,100 10,800

29,200 20,500 14,600 11,600 10,300 9,400 16,300 13,500 SJ150G/GH

29,200 20,400 14,500 11,500 10,200 9,300 16,200 13,400

NOTE: G-series are Standard. / GH series are HIDENS specification. Upper row: 60Hz

Lower row: 50Hz

NOTE

Actual capacities may be changed for improvement without notice.

Page 23: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-2

3.2 Treating Temperature

The treating capacity of the oil purifier depends mainly on the viscosity of feed liquid. To ensure that the

oil purifier operates efficiently, heat the feed liquid to specified temperatures of Table 3-2 as

appropriate.

Table 3-2

Oil type Treating temperature(℃)A heavy oil 14 mm

2/sec at 40℃ 40

C heavy oil 180~700 mm2/sec at 50℃ 98

100 mm2/sec at 40℃ (SAE#30) 90

Lubricating oil 150 mm

2/sec at 40℃ (SAE#40) 95

Fig. 3-1 shows the relationship between various oil temperatures and their viscosity.

How to obtain a treating temperature 【Ex.】Case of purifying a heavy oil of 45 mm2/sec (50℃)

Draw a dotted line that is parallel to the line of 40 mm2/sec at 50℃ and passes an intersection (point A)

between a horizontal line of 45 mm2/sec and a vertical line of 50℃. From the intersection between this

line and a horizontal line of 24 mm2/sec draw a line perpendicular to the horizontal axis, then read the

temperature falling on the foot; that is 67℃.

Thus the treating temperature of this heavy oil should be 67℃.

Temperature vs. Viscosity diagram

Fig. 3-1

Page 24: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-3

3.3 Gravity Disc

In the purifier operation it is necessary to hold the interface between the light liquid and heavy liquid in

the bowl within a definite rage. Therefore, the SELFJECTOR can employ gravity discs of various inside

diameters such that the outlet diameter of the heavy liquid side can be altered for interface position

adjustment. One gravity disc having a larger inside diameter, if incorporated, moves the interface

outward, and another disc having a smaller inside diameter moves the interface inward.

Selection of an appropriate gravity disc is one of the most important subjects for oil treatment with the

SELFJECTOR. Exercise sufficient care for this selection to avoid unintended purifier operation.

NOTE

At the delivery of a SELFJECTOR, the gravity disc and bowl come in each package.

Select an appropriate gravity disc and assemble it in the bowl according to Section 3.3.2

"Gravity Disc Selection Procedure".

3.3.1 Supplied gravity discs

! CAUTION

Before treating a different type and nature of oil, select a suitable gravity disc having an

inside diameter that fits the gravity of the treated oil.

Running the purifier with a gravity disc of incorrect diameter may cause oil outflow to the

heavy liquid side and water circulation over the light liquid side.

Table 3-3 shows the supplied standard gravity discs for the purifier operation and Table 3-4 shows the

gravity discs for the G-HIDENS operation.

NOTE

Actually supplied gravity discs differ for types of the treated oil. For detail refer to the attached

document and drawing.

Page 25: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-4

1. Gravity discs for purifier operation

Table 3-3

Model Inside diameter of gravity disc

SJ10G/GH 64 65 66.5 68.5 71.5 74 78 79

SJ20G/GH 64 65 66.5 68.5 71.5 75 77 78 82 83

SJ30G/GH 65 66.5 68.5 71.5 75 79 82 86 90

SJ50G/GH 86.5 88.5 91 94 98 103 107.5 113 115

SJ60G/GH 86 88.5 91 94 98 103 106.5 110.5 115

SJ70G/GH 87.5 91 94 98 103 107.5 113 119 122

SJ100G/GH 113 116 120 124 129 136 140.5 142 150 153

SJ120G/GH 113 116 120 124 129 136 140.5 142 146.5 150 153 160

SJ150G/GH 114 118 122 127 134 142 145.5 146.5 153 160

(mm)

2. Gravity discs for G-HIDENS operation

Table 3-4

Model Inside diameter of gravity disc

SJ10GH

SJ20GH 63

SJ30GH

SJ50GH

SJ60GH 84

SJ70GH

SJ100GH

SJ120GH 109

SJ150GH

(mm)

Page 26: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-5

3.3.2 Gravity disc selection procedure

3.3.2.1 Purifier operation

For purifier operation, use dedicated gravity discs for purifier. Table 3-5 below shows the model series

of SELFJECTOR versus the numbers of Figures in which gravity disc selection nomograms are given

for reference. Select appropriate gravity discs by models and kinds of treated oil accordingly.

Table 3-5

Model Fuel oil

(A heavy oil)

Fuel oil

(C heavy oil)

Lubricating oil

SJ10G/GH Fig. 3-3 Fig. 3-12 Fig. 3-21

SJ20G/GH Fig. 3-4 Fig. 3-13 Fig. 3-22

SJ30G/GH Fig. 3-5 Fig. 3-14 Fig. 3-23

SJ50G/GH Fig. 3-6 Fig. 3-15 Fig. 3-24

SJ60G/GH Fig. 3-7 Fig. 3-16 Fig. 3-25

SJ70G/GH Fig. 3-8 Fig. 3-17 Fig. 3-26

SJ100G/GH Fig. 3-9 Fig. 3-18 Fig. 3-27

SJ120G/GH Fig. 3-10 Fig. 3-19 Fig. 3-28

SJ150G/GH Fig. 3-11 Fig. 3-20 Fig. 3-29

3.3.2.2 G-HIDENS operation

For G-HIDENS operation, use dedicated gravity discs for G-HIDENS. (See Table 3-4)

NOTE

In the case of G-HIDENS operation, there is no need to change gravity discs according to

operating parameters such as gravity of treated oil.

For HIDENS purifier operation, select suitable gravity discs in accordance with the gravity disc selection

procedure for purifier operation described above.

Page 27: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-6

3.3.2.3 Gravity disc selection examples

[Example 1]

The specific gravity of treated oil at 15℃ is known.

Treating condition

Specific gravity of treated oil 0.925 at15℃Treating temperature 70℃Feed rate 3000 L/h

Selection method

1. From an intersection between falling curve ①of specific gravity of 0.925 and the vertical line

of 70℃, draw horizontal line ② to reach the

vertical line of 100℃.

2. Connect between the right end of line ② and

the point of 3000 L/h on the treating capacity

scale using straight line ③.

3. Read within which section of gravity disc Inside

diameter scale the intersection made by line ③ falls.

4. For this [Example 1] select a gravity disc

having an Inside diameter of φ79.

[Example 2]

The specific gravity of treated oil at a certain

temperature is known.

Treating condition

Specific gravity of treated oil 0.944 at50℃Treating temperature 98℃Feed rate 1250 L/h

Selection method

1. From an intersection between rising curve ④of specific gravity of 0.944 and the vertical line

of 50℃ (being converted to a specific gravity

at 15℃), draw curve ⑤ along the falling curve

to reach the vertical line of 98℃, then draw a

horizontal line to reach the vertical line of

100℃.

2. Connect between the right end of the

horizontal line and the point of 1250 L/h on the

treating capacity scale using straight line ⑥.

3. Read within which section of gravity disc Inside

diameter scale the intersection made by line ⑥ falls. For this [Example 2] select a gravity

disc having an Inside diameter of φ71.5.

Page 28: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-7

Fig. 3-2

Page 29: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-8

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ10G/GH (Fuel Oil: A Heavy Oil)]

Fig. 3-3

Page 30: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-9

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ20G/GH (Fuel Oil: A Heavy Oil)]

Fig. 3-4

Page 31: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-10

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ30G/GH (Fuel Oil: A Heavy Oil)]

Fig. 3-5

Page 32: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-11

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ50G/GH (Fuel Oil: A Heavy Oil)]

Fig. 3-6

Page 33: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-12

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ60G/GH (Fuel Oil: A Heavy Oil)]

Fig. 3-7

Page 34: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-13

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ70G/GH (Fuel Oil: A Heavy Oil)]

Fig. 3-8

Page 35: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-14

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ100G/GH (Fuel Oil: A Heavy Oil)]

Fig. 3-9

Page 36: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-15

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ120G/GH (Fuel Oil: A Heavy Oil)]

Fig. 3-10

Page 37: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-16

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ150G/GH (Fuel Oil: A Heavy Oil)]

Fig. 3-11

Page 38: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-17

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ10G/GH (Fuel Oil: C Heavy Oil)]

Fig. 3-12

Page 39: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-18

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ20G/GH (Fuel Oil: C Heavy Oil)]

Fig. 3-13

Page 40: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-19

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ30G/GH (Fuel Oil: C Heavy Oil)]

Fig. 3-14

Page 41: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-20

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ50G/GH (Fuel Oil: C Heavy Oil)]

Fig. 3-15

Page 42: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-21

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ60G/GH (Fuel Oil: C Heavy Oil)]

Fig. 3-16

Page 43: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-22

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ70G/GH (Fuel Oil: C Heavy Oil)]

Fig. 3-17

Page 44: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-23

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ100G/GH (Fuel Oil: C Heavy Oil)]

Fig. 3-18

Page 45: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-24

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ120G/GH (Fuel Oil: C Heavy Oil)]

Fig. 3-19

Page 46: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-25

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ150G/GH (Fuel Oil: C Heavy Oil)]

Fig. 3-20

Page 47: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-26

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ10G/GH (Lubricating Oil)]

Fig. 3-21

Page 48: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-27

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ20G/GH (Lubricating Oil)]

Fig. 3-22

Page 49: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-28

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ30G/GH (Lubricating Oil)]

Fig. 3-23

Page 50: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-29

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ50G/GH (Lubricating Oil)]

Fig. 3-24

Page 51: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-30

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ60G/GH (Lubricating Oil)]

Fig. 3-25

Page 52: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-31

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ70G/GH (Lubricating Oil)]

Fig. 3-26

Page 53: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-32

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ100G/GH (Lubricating Oil)]

Fig. 3-27

Page 54: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-33

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ120G/GH (Lubricating Oil)]

Fig. 3-28

Page 55: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-34

SELECTION NOMOGRAM OF GRAVITY DISC, [Model SJ150G/GH (Lubricating Oil)]

Fig. 3-29

Page 56: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-35

3.4 Lubrication Oil

Lubrication oil in the gear case lubricates each

bearing of the vertical and horizontal shafts as well

as the acceleration gear.

The available lubrication method includes the oil

bath and splash lubrication by a spiral gear.

As the maintenance performance of the lubrication

oil seriously affects the life of each power

transmission unit, sufficient care should be

exercised on its handling.

For this lubrication, remove the gear cover or

lubrication plug attached on the gear cover.

! CAUTION

Before supplying the lubrication oil, be sure to stop the SELFJECTOR. The oil becomes very hot

during operation. To avoid the risk of the oil being scattered around to burn operator's hand or

hurt his eyes, do not remove the plug or gear cover when the SELFJECTOR is in operation.

3.4.1 Oil quantity

! CAUTION

Oil quantity should be checked with the SELFJECTOR being held

horizontally.

Refilling the lubrication oil as to exceed the upper red line (H) may

cause additives contained in the lubrication oil to deposit into sludge,

which can adversely affect the lubrication effect. Take sufficient care

not to exceed the upper red line (H).

Refer to

Table 3-6 for appropriate oil quantities. Refill the oil up until the red

line (H) on the oil gauge as shown in Fig. 3-31.

During operation make sure that the oil level falls in-between the red lines (H) and (L).

Table 3-6

Model SJ10G/GH

SJ20G/GH

SJ30G/GH

SJ50G/GH

SJ60G/GH

SJ70G/GH

SJ100G/GH

SJ120G/GH

SJ150G/GH

Oil quantity(L) 6.3 11.5 16

Oil gauge

Fig. 3-30

L

H

Red line

Fig. 3-31

Page 57: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-36

3.4.2 Optimum viscosity

Optimum viscosity ISO VG150 (135 165 mm2/sec)

Refer to Section 3.4.3 for recommended lubricating oil brands.

NOTE

Synthetic lubricating oil should be within an equivalent range of ISO VG220 (198 to 242 mm2/S).

! CAUTION

Before using synthetic lubricating oil, make sure of its suitability by the procedure described in

the "Maintenance Manual".

Page 58: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-37

3.4.3 Recommended brands

For the recommended brands refer to Table 3-7.

NOTE

Please consult our company when using lubricating oil other than herein recommended or

synthetic lubricating oil.

For the replacement period of the lubricating oil and precautions for use of synthetic lubricating

oil, refer to Section 3.2 of the "Maintenance manual".

Table 3-7

Manufacturer Brand name Viscosity

mm2/sec at40℃

BP ENERGOL GR-XP150 140

CALTEXMEROPA LUBRICANT 150 URSA OIL P150

143140

CASTROL CASTROL ALPHA SP150 159

CHEVRONGEAR COMPOUND EP150 MACHINE OIL AW150

142143

COSMO OIL COSMO GEAR SE150 153.8

EXXONMOBILSPARTAN EP150 MOBIL GEAR 629

144152

GULF EP LUBRICANT HD150 150

IDEMITSU KOSAN DAPHNE SUPER GEAR OIL 150 150.4

JAPAN ENERGY JOMO REDUCTUS 150 149.4

NIPPON OIL BONNOC M150 154

SHELLSHELL OMALA OIL 150 SHELL TELLUS OIL C150

150150

TEXACOMEROPA LUBRICANT 150 REGAL R&O 150

143150

Page 59: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-38

3.5 Sludge Discharge Interval

! CAUTION

Too long sludge discharge intervals may cause defective separation and mechanical damage on

the unit.

The optimum sludge discharge interval varies with the operation method and nature of the treated oil,

etc., which makes it hard to be uniformly determined.

Too long intervals may accelerate the contamination inside the bowl and result in sludge deposition,

whilst too short intervals may reduce the operation efficiency.

NOTE

To determine an optimal discharge interval, it is a recommended practice to perform a test run

under practical conditions for a certain length of time and find an interval commensurate to

sludge concentration in the treated oil while watching the internal state of the bowl partial

accumulation of sludge, contamination of disc(1), etc.

3.5.1 Discharge Interval (Total discharge)

The general discharge intervals and amount of sludge discharge for the treatment of fuel and lubricating

oils by the manual type GAP-11 and automatic types GBC-1 and GSH-1 are as shown in Table 3-8 and

Table 3-9, respectively.

Table 3-8

Fuel oil Lubricating oil

A Heavy Oil C Heavy Oil (380mm2/s at50℃) Cross-head engine Trunk piston engine

Standard Standard Standard Standard

Sludge discharge times

(time / day) 12 24 12 24

Sludge discharge interval

(min)120 60 120 60

Bowl washing times

(time / day) 0 0 2 4

Table 3-9

SJ10G/GH SJ20G/GH SJ30G/GH SJ50G/GH

SJ60G/GH

SJ70G/GH SJ100G/GH

SJ120G/GH

SJ150G/GH

Amount of

sludge

discharge(L / time) 2.0 2.3 3.5 7.1 8.4 17.2 19.2

Page 60: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-39

3.5.2 Discharge Interval (HIDENS specification)

For reference, Table 3-10 shows the general discharge intervals where a fuel oil or lubricating oil is

treated in automatic specification GSH-1.

The automatic specification GSH-1 discharges sludge in the total discharge and separated water in the

partial discharge. In some cases, however, total discharge of separated water with sludge takes place,

depending on the amount of time spent for water detection. The lubricating oil treatment can include

post-total discharge the bowl washing process at a certain rate. The sludge discharge rates for different

types are generally as shown in Table 3-9, though they vary with the frequency of water detection.

Table 3-10

Fuel oil Lubricating oil

A Heavy Oil C Heavy Oil (380mm2/s at50℃) Cross-head engine Trunk piston engine

Standard Standard Standard Standard

Sludge discharge times

(time / day) 12 24 12 24

Sludge discharge interval

(min)120 60 120 60

Bowl washing times

(time / day) 0 0 2 4

NOTE

No the bowl washing process is included, except in lubricating oil treatment.

Table 3-11 shows the amount of separated water in the partial discharge.

Table 3-11

SJ10GH SJ20GH SJ30GH SJ50GH

SJ60GH

SJ70GH SJ100GH

SJ120GH

SJ150GH

Amount of

separated

water(L / time) 0.8 - 1.2 0.9 ? 1.4 1.4 ? 2.1 2.8 ? 4.3 3.4 ? 5.0 6.9 ? 10.3 7.7 ? 11.5

Page 61: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-40

! CAUTION

Operate the lubricating oil purifier continuously as long as possible.

Should the purifier be forced to stop for the reasons below, operate it for approximately 12

hours with sludge discharged at 10 to 20 minutes intervals before setting for discharge at

standard intervals after taking into consideration of the system oil at the time of normal

operation.

Restarting the engine and purifier after stopping

them in the anchorage or dock.(This is because

the sludge density increases at the inside

bottom of the sump tank due to natural

sedimentation.)

Restarting the purifier after once stopping it

with the engine kept running.

Trunk piston engineCross-head engine

Length of Purifier Shutdown

12 h or more24 h or more

6 h or more 12 h or more

Page 62: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-41

3.6 Operating Water

The SELFJECTOR requires;

Operating water for opening/closing bowl,

Sealing water,

Replacement water,

Regulating water (when lubricating oil is treated),

Bowl washing water (when lubricating oil is treated).

Normally, pure water is used in all cases. To ensure proper use of the SELFJECTOR, the water

pressure should be correctly set by means of reducing valve for operating water.

Fig. 3-32 Triple Solenoid Valve Unit (GBC-1)

Fig. 3-33 Quadruple Solenoid Valve Unit (GSH-1)

Page 63: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-42

3.6.1 Operating water quality

! CAUTION

When hard water is used, scale will be produced on the inside surface of the water

supplying device, drain nozzle, or solenoid valve, which may cause various troubles.

The harder the water, the more scales on the water supplying device and pilot valve. To

prevent it, the cleaning intervals should be as short as practically possible.

Since the operating water is used for the opening/closing valve of the purifier bowl, its quality should be

pure, transparent and soft water such that it can prevent the valve from scaling or corrosion.

Use that quality of operating water, as follows:

Evaporation remainder 10 mg/L or less

Total hardness 110 mg/L or less : as CaCO3 /L (Hardness 6 dH or less)

pH value 6.5 to 7.5

Salt content 100 mg/L or less: (Cl- 60 mg/L or less)

3.6.2 Setting pressure of operating water

Use the following operation water pressure for each of automatic specifications.

Automatic type Discharge type Set pressure

(Standard value)

Required pressure

Manual, GAP-11

GBC-1, GBC-2 Total discharge 0.3 MPa (3.0 kgf/cm

2)

0.35 to 0.5 MPa

(0.35 to 0.5 kgf/cm2)

GSH-1Total and Partial

discharge0.25 MPa (2.5 kgf/cm

2)

0.35 to 0.5 MPa

(0.35 to 0.5 kgf/cm2)

! CAUTION

Where the primary pressure of operating water is lower than 0.2 MPa (2 kgf/cm2), then sludge

discharge efficiency will be decreased. Otherwise a pressure exceeding 0.75 MPa (7.5 kgf/cm2)

may cause the solenoid valve malfunctioning.

Page 64: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-43

To adjust the operating water pressure, use the adjust screw on top of the reducing valve while reading

the valve's pressure gauge. (See Fig. 3-17)

How to pressure adjustment with adjust screw

Turn clockwise: Pressure increases.

Turn counter-clockwise: Pressure decreases.

The reducing valve has been shop-adjusted for optimal water pressure according to manual and

automatic specifications shown in Section 3.6.2.

! CAUTION

When setting or adjusting the operating water pressure during running, use the manual handle

of SV2 while running operating water for bowl closing. When the purifier is not running, perform

this with the operating water inlet tube (Teflon) removed. Otherwise, the operating water could

find its way to the gear case to damage bearings.

NOTE

The pressure of the operating water reducing valve may increase after the SV2 solenoid valve

closes, but this is not an anomaly.

Page 65: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-44

3.6.3 Operating water for opening bowl

The operating water for opening bowl is used to force down the main cylinder to open the bowl, letting

out sludge and water accumulated in the bowl in the "total discharge" or "partial discharge".

In the case of total discharge, the operating water is regulated by the solenoid valve SV1 and

introduced into the bowl opening water pressure chamber via feeding device.

In the case of partial discharge (GSH-1 specification models only), the operating water is regulated

by the solenoid valve SV9 and introduced into the bowl closing water pressure chamber via feeding

device. When the bowl closing water pressure chamber has been filled up, the bowl opening water

overflows into the bowl opening water pressure chamber, depressing the main cylinder to open the

bowl instantly.

3.6.4 Operating water for closing bowl

The operating water for closing bowl is used to force up the main cylinder to close the bowl. The bowl

closing water is regulated by the solenoid valve SV2 and introduced into the bowl closing water

pressure chamber via feeding device. The bowl closing water is introduced intermittently into the bowl

closing water pressure chamber for a predetermined period of time during purifier operation.

! CAUTION

Where the primary pressure of operating water is lower than 0.2 MPa (2.0 kgf/cm2), the bowl

closing failure could occur.

Fig. 3-34

Valve sheet

Pilot valve

Supply water

Bowl closing water pressure chamber

Bowl opening water pressure chamber

Operating water for closing bowl

Operating water for opening bowl

To sealing water and replacement inlet

Main seal ring

Main cylinder

Operating water for opening bowl

Watercourse for closing bowl

Watercourse for opening bowl

Quadruple solenoid valve unit

Page 66: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-45

3.6.5 Quantity of sealing water/regulating water and replacement water, washing water

! CAUTION

If the sealing water and replacement water are not adequate in quantity;

Oil loss during sludge discharge will increase,

Water circulates over the light liquid side, or

Oil flows out from the heavy liquid side.

Therefore, be sure to set correct quantities of these waters.

Sealing water is used to form a water phase within the bowl prior to performing a purifier-run and prevent feed liquid from flowing out of the heavy liquid side when it is supplied. On the other hand, replacement water is used to collect oils in the bowl before discharging sludge so that the oil loss can be minimized. The quantities of sealing water and replacement water required by different models shown below, respectively.

3.6.5.1 Quantities of sealing water, replacement water (Manual, GAP-11, GBC-1)

Table 3-12 shows the quantities of replacement water and sealing water for Manual, GAP-11, GBC-1

Type.

Table 3-12

SJ10G SJ20G SJ30G SJ50G

SJ60G

SJ70G SJ100G

SJ120G

SJ150G

Quantity of Sealing Water (L / time) 1.2 1.3 1.6 3.5 4.0 8.4 8.0

Quantity of Replacement Water (L / time) 0.6 1.0 1.6 2.8 3.7 7.8 9.5

3.6.5.2 Quantities of replacement water, regulating water (GSH-1)

Table 3-13 shows the quantities of regulating water and replacement water for GSH-1 Type. On

lubricating oil purifier for G-HIDENS specifications, regulating water is supplied before oil feed.

Table 3-13

SJ10GH SJ20GH SJ30GH SJ50GH

SJ60GH

SJ70GH SJ100GH

SJ120GH

SJ150GH

Quantity of Regulating Water (L / time) 0.1 0.2 0.3 0.5 1.3 1.6

Quantity of Replacement Water

for Total discharge(L / time) 1.3 1.4 1.9 4.1 5.2 10.2 11.0

Quantity of Replacement Water

for Partial discharge(L / time) 0.3 0.7 1.2 1.7 1.7

NOTE

No regulating water needs to be fed into a fuel oil purifier.

Page 67: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-46

3.6.6 Quantities of washing water

In the case of lubricating oil purifier, washing water is introduced into the bowl to clean the inside at

predetermined intervals of sludge discharge. Solids in the bowl are removed with washing water in total

discharge. The quantities of washing water required by different models are as shown below.

Table 3-14

SJ10G/GH SJ20G/GH SJ30G/GH SJ50G/GH

SJ60G/GH

SJ70G/GH SJ100G/GH

SJ120G/GH

SJ150G/GH

Washing water (L / time) 1.6 1.8 2.5 5.2 6.1 12.8 14.2

NOTE

No washing water needs to be fed into a fuel oil purifier.

Page 68: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-47

3.7 Partial Discharge Setting/Adjustment (GSH-1)

Partial discharge (amount of sludge) adjustment can be accomplished through pressure control by the

reducing valve for operating water. The Multi-Monitor (MM-3) tells whether or not partial discharge is

optimal.

3.7.1 Setting/adjustment of partial discharge

1. Set the timer (T011) of the control panel to 0.6 sec.

2. Set the reducing valve connected to the solenoid valve unit for secondary pressure at a standard

preset level of 0.25 MPa (2.5 kgf/cm2).

NOTE

The primary pressure of the supply water line should be 0.35 to 0.5 MPa (3.5 to 5.0 kgf/cm2).

The supply water pressure beyond 0.75 MPa (7.5 kgf/cm2) could cause a reducing valve

failure.

To adjust the reducing valve for optimum secondary pressure, use the adjust screw that is exposed if

the seal on top of the valve is removed. Turning the adjust screw as required, set the reducing valve for

desired pressure while reading its pressure gauge. Turning the adjust screw clockwise increases the

secondary pressure and a counter-clockwise turn decreases it.

Proper pressure setting on the reducing valve provides the discharge rates of Table 3-11 eparated 밪Water Discharge Rates (Partial Discharge)? After pressure setting/adjustment, check through the

Multi-Monitor that sludge discharge is optimal in accordance with Section 3.7.2 onitoring Partial 밠Discharge?

Fig. 3-35

Quadruple solenoid valve unit

Page 69: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-48

NOTE

With the reducing valve for operating water set (shop-adjusted) for secondary pressure

at a standard preset level of 0.25 MPa (2.5 kgf/cm2), be sure to ascertain that partial

discharge is optimal by measuring its quantity.

Increasing the reducing valve secondary pressure increases sludge discharge. To

decrease, lower the pressure.

The pressure of the operating water reducing valve may increase after the SV2 solenoid

valve closes, but this is not an anomaly.

3.7.2 Measure of the amount of partial discharge

The measure of the partial discharge is available only in the automatic control (GSH-1) system.

To measure, there are two methods:

1. Continuous measurement during normal operation.

2. One-time measurement for discharge adjustment or check

In this paragraph, the procedure for one-time measurement will be described. Before measure of the

partial discharge, make sure that the sensor is in position by reference to Section 4.3.3 hecking 밅Proximity Switch Position?in this manual.

! CAUTION

Described below is the general procedure for checking the amount of partial discharge. Prior to

starting operation, be sure to refer to Section 5. “Operation“ in this manual. Given instructions

are subject to the SELFJECTOR being ready to start. (The piping had completed for operation).

1. Set the power switches of the starter, automatic control panel and Multi-Monitor to ON in that order.

2. Remove the front cover of the Multi-Monitor and check that all internal switches are in the

designated positions.

1) Check that the 50Hz/60Hz selector switch is in the position of power frequency for the

SELFJECTOR. (See Fig. 3-36)

2) Set the DD alarm output switch to OFF. (See Fig. 3-36)

3) Set the Partial ON/OFF switch to OFF. (See Fig. 3-36)

NOTE

Each model of the SELFJECTOR has a different range of optical discharge.

Correct measurement cannot be performed without proper settings. (Refer to Section 4.1.2)

3. Start the SELFJECTOR in accordance to the start-up procedure described in Section 5.

peration?밢4. Ascertain that the SELFJECTOR has entered into purifier operation. Purifier operation is started in

response command signals received by the Multi-Monitor from the automatic control panel, when

the confirmation LED for input signal "Feeding"(green) in the Multi-Monitor and the otation 밨Display LED?green) on the Multi-Monitor are illuminated.

5. Press the Discharge measurement switch in the Multi-Monitor. The green "Measuring" LED of the

confirmation LED for partial discharge quantity is illuminated. This indication means that the purifier

is ready for measurement. (See Fig. 3-36)

Page 70: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-49

6. Then, press the IS밆 -T?push button on the automatic control panel.

7. The sequence of the automatic control panel proceeds to the "sludge discharge" process and

sludge discharge takes place.

8. The revolution sensor (proximity switch) installed in the purifier picks a drop in horizontal shaft

speed and its output signal equivalent to the quantity of sludge discharge effected is sent to the

Multi-Monitor.

9. The input is indicated through appropriate Partial Discharge LED in the Multi-Monitor; red LED for

"OVER", green LED for "JUST" or red LED for "UNDER". (See Fig. 3-36)

10. If "OVER" LED (red) or "UNDER" LED (red) is illuminated, regulate the secondary pressure of the

reducing valve for operating water (refer to Section 3.7.1 and perform above operations from Step 5

downward to adjust the quantity of discharge until the "JUST" LED (green) is illuminated.

NOTE

A change in reducing valve setting must be followed by discharge tests to have line pressure

stabilized before proceeding to discharge measurement.

Page 71: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-50

Fig. 3-36

Control / LED Function

Power switch ON/OFF control of Multi-Monitor power

50Hz / 60Hz selector switch Used to select power frequency for SELFJECTOR.

Partial ON / OFF switch Setting to ON effects constant monitoring to determine whether or not discharge is proper. With the switch in OFF position, there is no monitoring of discharge.

Discharge measurement switch

Used for one-time measurement of sludge discharge. With Partial ON/OFF switch in OFF position, pressing this switch once effects measurement of sludge discharge only once, with "Measuring" LED (green) illuminated.

OVER (red) Lit when discharge is more than preset.

JUST(green) Lit when discharge is optimal as preset.

UNDER(red) Lit when discharge is less than preset.

Partialdischarge

confirmationLED MEASURING (green) Lit when discharge measurement switch is pressed.

DD alarm output switch Setting the switch to OFF cuts off No Discharge alarm signal. There is no alarm output to the automatic control panel and alarm panel.

( )( )( )( )

Page 72: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-51

3.8 Timer Setup on the Automatic Control Panel

Literally the automatic control panel automatically controls each operation of the SELFJECTOR.

This automatic control panel has incorporated various timers such as to control each solenoid valve, etc.

Correct settings of these timers are the keys to normal and efficient machine operations. The set

periods of these timers will vary depending on the flow rate of the operating water. Consult

Table 3-15 and Table 3-16 for standard settings (guidelines) at each operation mode.

3.8.1 GBC-1 timer settings(guideline)

Fig. 3-37 shows the operation timing of each timer incorporated in the automatic control panel during

sludge discharge process and purifying process.

Fig. 3-37

(Remarks)

Figures in the oblong boxes above denote timer numbers.

For treatment of lubricating oil, bowl washing process is added downstream of the

sludge discharge process.

……Replacement water supply periodduring sludge discharge process

Operation intervals of each solenoid valveduring sludge discharge process

Sealing water supply period during sludge discharge process

Operating water supply for closing bowl

Treated liquid feeding period (sludge discharge interval)

Purifying process

Closing the feed valve

Sludge discharge process

Sealing water

Intermittent water supply timer

Water for closing bowl

Intermittent water supply

Operating water supply period for opening bowlduring sludge discharge process

Sludge discharge

Purifying process Sludge discharge process

Water for closing bowl

Replacement water

Page 73: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-52

3.8.1.1 GBC-1 type automatic control panels

Table 3-15 Timer Counter Setting Guideline (GBC-1)

ItemTimer

N o .U n i t SJ10G SJ20G SJ30G SJ50G SJ60G SJ70G SJ100G SJ120G SJ150G

Interval sec 15 15 15 15 15 15 20 20 20

Opening bowl sec 3

Replacement water sec 5 8 12 14 14 19 29 29 32

Sealing water sec 9 10 12 18 18 20 32 32 27

Intermittent water supply min 10

Operating water supply for

closing bowlsec 5

Discharge interval min NOTE1

Fuel oilBowl washing

water Lubricating oil sec

12 13 19 26 26 31 48 48 47

Fuel oil 0Bowl washing

counter Lubricating oiltimes

6

NOTE1: For discharge intervals, refer to Section 3.5 ludge Discharge Interval? 밪NOTE

Timer settings for sealing water and replacement water in the above list are based on the

feed rate at 8 L/min. for SJ10G to 30G, at 12 L/min. for SJ50G to 70G, at 16 L/min. for SJ100G

and 120G and at 18 L/min. for SJ150G. For practical setting, always measure the flow rate

actually and select proper values accordingly.

Fuel oil purifiers have no bowl washing process.

Page 74: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-53

3.8.2 GSH-1 type timer settings (guideline)

Normally, the G-HIDENS type oil purifier discharges sludge in the total discharge mode and separated

water in the partial discharge mode on a command signal from the Multi-Monitor with Water Detector

Function.

For G-HIDENS specification, various timers in the automatic control panel GSH-1 are actuated at the

timings shown in Fig. 3-38 for sludge discharge process and bowl washing process. For action timings

for total discharge timers, see Fig. 3-37. For specific setting requirements for timers in the automatic

control panel GSH-1, refer to the Operation Manual 3.

Fig. 3-38

(Remarks)

Figures in the oblong boxes above denote timer numbers.

If the Water Detector is activated after the lapse of monitoring time (C022), total

discharge of sludge and separated water is effected.

For the timing of total discharge, refer to Section 3.8.1.

In the case of lubricating oil treatment, washing process is effected as many times as

set on the washing counter (C023) after sludge discharge process (total discharge).

For lubricating oil treatment, regulating water feed is added before washing process

and after separated water discharge process (partial discharge).

Operation intervals of each solenoid valve during separated water discharge process

Operating water supply for closing bowl

Treated liquid feeding period (sludge discharge interval)

Closing the feed valve

Water for closing bowl

Intermittent water supply

Operating water supply period for opening bowl during separated water discharge process

Separated water discharge

……Command to discharge of separated water from the water detector

Monitoring time

Water detection

Purifying process Sludge discharge process(Total discharge)

Intermittent water supply timer

Purifying process Purifying process Sludge discharge process(Total discharge)

Separated water discharge process(Partial discharge)

Replacement water(Partial)

Page 75: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual23-54

3.8.2.1 GSH-1 type automatic control panels

Table 3-16 Timer Counter Setting Guideline (GSH-1)

ItemTimer

N o . Unit SJ10G SJ20G SJ30G SJ50G SJ60G SJ70G SJ100G SJ120G SJ150G

Interval T000 sec 15 15 15 15 15 15 20 20 20

Opening bowl T001 sec 3

Replacement water T002 sec 10 11 14 21 21 26 38 38 37

Fuel oil 0Regulating

water Lubricating oil T003 sec

1 1 2 3 3 3 5 5 5

Fuel oil 0Bowl washing

water Lubricating oilT004 sec

12 13 19 26 26 31 48 48 47

Opening bowl(partial) T011 sec 0.6

Replacement

water(partial)T012 sec 2 2 2 3 3 6 6 6 6

Fuel oil 0Regulating

Water(partial) Lubricating oilT013 sec

1 1 2 3 3 3 5 5 5

Intermittent water supply C014 min 15

Operating water supply for

closing bowl T016 sec 5

Discharge interval C015 min NOTE1

Detection count reset C026 min 30

Water detection setting

counterC027 times 6

Monitoring time C022 min 20

Fuel oil 0Bowl washing

counter Lubricating oil C023 times

6

NOTE1: For discharge intervals, refer to Section 3.5 ludge Discharge Interval? 밪 NOTE2: Please use C021 by fixing to 1.

Timer settings for sealing water and replacement water in the above list are based on the

feed rate at 8 L/min. for SJ10GH to 30GH, at 12 L/min. for SJ50GH to 70GH, at 16 L/min. for

SJ100GH and 120GH and at 18 L/min. for SJ150GH. For practical setting, always measure

the flow rate actually and select proper values accordingly.

Fuel oil purifiers have no regulating water feeding process and bowl washing processes.

! CAUTION

When SJ10GH to 150GH types are used in the total discharge mode (purifier operation), select

an appropriate gravity disc that fits the specific gravity of feed liquid and install it in position.

Then, fully open the shut-off valve and set the Water Detector selector dial to No working

position. (Refer to Section 6.4.2.4 in the Operation Manual 1.) In this case, the setting

values of the timers T002, T003 and C014 refer to Table 3-15 in 3.8.1.1., and set the timers

T011, T012, T013, C022, C026 and C027 to 0. If operated without changing for the setting

values the Leakage Monitor function of the Multi-Monitor is actuated by overflow and

gives an alarm.

NOTE

Page 76: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-1

4 Multi-Monitor

4.1 Multi-Monitor

The Multi-Monitor, which is an integrated detection and display instrument, is available in three types.

The Multi-Monitors vary in the functions that have with applicable types of automatic system (Refer to

Table 4-1).

Table 4-1

NOTE

See Table 4-1 above for the functions incorporated in different types of the Multi-Monitor.

4.1.1 Kinds of switches and Setting parameters

For the Multi-Monitor, there are parameters to be selected through switches, etc. and those preset in

internal memories. Fig. 4-1 identifies the switches, etc. and their locations. For memory preset items,

see Table 4-2.

Functions MM-1 MM-2 MM-3

Applied automatic control device GBC-1

Alarm panel: GAP-11

GBC-1

(with DD)

GSH-1

Leakage Monitor Function (LM) ○ ○ ○Indication of inlet temperature ○ ○ ○Indication of flow rate ○ ○ ○Indication of outlet pressure ○ ○ ○Discharge Detector Function (DD) ― ○ ○Indication of revolution number ― ○ ○Water Detector Function (WD) ― ― ○Communication (RS485) ― ○ ○

Fig. 4-1

::::

Page 77: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-2

Table 4-2

Memory preset

item number Setting items Operation

1 Kinds of oil YES

2 SELFJECTOR-G model YES

3 Gear pump model YES

4 Minimum light liquid pressure (MPa) YES

5 LM trigger pressure △P (MPa) YES

6 Delay timer (sec) YES

7 Hold timer (sec) YES

8 Feed oil temperature (℃) NO

9 Detection exclusion temperature (℃) NO

10 Minimum WD pressure (MPa) YES

11 Maximum heavy liquid pressure (MPa) NO

12 WD trigger pressure △W (MPa) YES

13 Light liquid pressure (MPa) YES

14 Pressure averaging time (sec) NO

Page 78: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-3

4.1.2 Accessing Memory Preset Items and Changing Memory Settings

4.1.2.1 Accessing Multi-Monitor Memory Preset Items

To access the memory preset items of the Multi-Monitor, use the function setting switches (SW1 to 4).

Press the function setting switch 4 (SW4: Enter) for 2 seconds and release. A preset item number

appears in the upper seven-segment display with the current preset value indicated in the lower. Keep

pressing the function setting switch 1 (SW1: Select) until the desired preset item number is displayed.

4.1.2.2 Changing Multi-Monitor Memory Preset Value

When it becomes necessary to change a memory preset value, access the number of the item to be

changed through the function setting switch 1 (SW1: Select) and change it by means of the function

setting switch 2 (SW2: Forward) or the function setting switch 3 (SW3: Backward). The preset value

increases or decreases at minimum variable steps predetermined for each preset item. Key in a desired

new value and press the function setting switch 4 (SW4: Enter). The new value is registered in the

memory.

NOTE

Preset values cannot be changed without pressing the function setting switch 4 (SW4).

4.1.2.3 Locking Display

During normal operation, "flow rate" is always indicated in the upper seven-segment LED display, and

"feed liquid temperature"/"light liquid pressure" appears in the lower changing (incrementally) at steps of

5 seconds.

At the start of operation or during operation, when back pressure at the light liquid outlet becomes

necessary to adjust to optimize the Leakage Monitor function of the Multi-Monitor or for other reason,

press the Pressure Display Lock switch on the Multi-Monitor panel once. This freezes the "light liquid

pressure" appearing in the lower seven-segment LED display of the Multi-Monitor. (Flow rate remains

indicated in the upper LED display.) To release the lock to resume the incremental display of pressure,

press the Pressure Display Lock switch again.

NOTE

To lock the display of light liquid pressure only, press the Pressure Display Lock switch at

the left of the Multi-Monitor panel once, and the incremental display is switched to the locked

indication. To resume the incremental display, press this select switch once.

By long pushing the function setting switch 2 and 3 (SW2: Forward, SW3: Backward) at the same time,

the incremental display is switched to the "feed liquid temperature", the "light liquid pressure", the

"revolution number" and the "water pressure" indication by repetition.

The evolution뱑 number is indicated by MM2 (with DD function) and MM-3, the ater pressure? is 뱖indicated by MM-3 only. LEDs (green) on the Multi-Monitor panel are illuminated to confirm the

indications.

By detaching from the function setting switch 2 (SW2: Forward), the display indicates only the "feed

liquid temperature" and the "light liquid pressure" indication by repetition incrementally.

Page 79: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-4

4.1.2.4 Default of Setting Value

Factory-set default values for the respective preset items are as shown in Table 4-3.

! CAUTION

At test running, listed default values require adjustment according to the SELFJECTOR

specification and model.

Table 4-3

No Setting items Selection range of

settingMM1 MM2 MM3

1 Power switch ON / OFF OFF OFF OFF

2 LM alarm output switch ON / OFF OFF OFF OFF

3 DD alarm output switch ON / OFF ― OFF OFF

4 Water Detection output switch ON / OFF ― ― OFF

5 Kinds of oil FO / LO FO*1

FO*1

FO*1

6 SELFJECTOR model

10G,20G,30G,

50G,60G,70G,

100G,120G,150G

10G*1

10G*1

10G*1

7 Gear pump model 10G,20G,30G,

50G,70G,100G10G*

110G*

110G*

1

8Light liquid pressure

(MPa)0.03~0.30 0.15*

10.15*

10.15*

1

9LM trigger pressure (△P) (MPa)

0.010~0.050 0.02 0.02 0.02

10Minimum light liquid pressure

(MPa)0.03~0.30 0.12*

10.12*

10.12*

1

11Delay timer (sec)

5~120 40 40 40

12Hold timer

(sec)5~120 15 15 15

13 Partial discharge detection function ON / OFF ― OFF OFF

14 Frequency 50Hz / 60Hz 60Hz*1

60Hz*1

60Hz*1

15WD trigger pressure (△W)

(MPa)0.010~0.10 ― ― 0.05

16Minimum WD pressure

(MPa)0.010~0.10 ― ― 0.03

NOTE*1: The default value surely requires setting change according to machine specification and

operation conditions. And please set various switches to ON position according to

directions of operation manuals.

Page 80: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-5

4.1.3 Wiring

Fig. 4-2 is a general view of the Multi-Monitor terminal layout.

Table 4-4 lists the terminals by use and connection.

Connect sensor output signal lines by using furnished wires.

To facilitate connection, strip the wire end 5 to 6 mm long.

Connect wires to the terminal board as follows:

1. Put a small standard screwdriver in the appropriate screwdriver inserting slot above the terminal to

which the wire is connected and depress the internal metal piece. This opens the snap-in metal

piece to hold the wire in the cable plug receptacle below the screwdriver slot.

2. Plug in the wire stripped at end 5 to 6mm long. (See Fig. 4-3)

3. Remove the screwdriver, and the wire should be held in place.

4. Pull the wire lightly to check that it is firmly connected.

Fig. 4-2

Fig. 4-3

Page 81: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-6

Table 4-4

Terminal

Number

Terminal

Number

MM1MM2

MM3

Connection Connect to

MM1MM2

MM3

Connection Connect to

1 1 Power source (DC24V) 7 13 Temperature Signal (Black)

2 2 GND 8 14 Temperature signal (Red)

Temperature sensor

The color of a tube :black

3 3 Leakage Signal 9 15 Oil inlet pressure signal

(Black) - 4 No discharge signal 10 16 Oil inlet pressure signal

(Green)― 5 Highly water signal 11 17 Oil inlet pressure signal

(Red)

Oil inlet pressure

sensor

The color of a tube :green

6 6 Feeding signal 12 18 Oil outlet pressure signal

(Black) ― 7 Discharging signal

Control panel

Alarm panel

Starter

13 19 Oil outlet pressure signal

(Yellow) ― 8 Spare output Revolution signal

(Collector) 14 20

Oil outlet pressure signal

(Red)

Oil outlet pressure

sensor

The color of a tube :yellow ― 9 Spare output Revolution signal

(Emitter) ― 21

Circulation line

pressure signal (Black) ― 10 Revolution signal (Black) ― 22 Circulation line

pressure signal (Pink) ― 11 Revolution signal (White) ― 23 Circulation line

pressure signal (Red)

Circulation line

pressure sensor

(MM-3/GSH-1)

The color of a tube :blue― 12 Revolution signal (Red)

Revolution sensor

(MM-3: Standard)

(MM-2: Option)

The color of a tube :white 15

16― Leakage Signal (b/a contact)

Alarm panel

Starter

NOTE: 1. The terminal board number 24 of the Multi-Monitor (MM2, MM3) is for optional function. 2. The terminal number 15 is used for b-contact?and the terminal number 16 is used for a-contact

Page 82: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-7

4.2 Leakage Monitor Function (LM)

NOTE

The Leakage Monitor Function of the Multi-Monitor is a protective device that detects treated

oil leaking from the sludge outlet or heavy liquid outlet of the bowl by means of a pressure

sensor. Be sure that settings are correct to prevent a false alarm.

4.2.1 Setting Up the Leakage Monitor Function

Fig. 4-4 shows principal switches necessary for setting the Leakage Monitor Function.

Switch Function Remarks

Power switch ON/OFF control of power Power is turned on with the switch in ON position,

and off in OFF position.

LM alarm output

switch

ON/OFF control of LM

alarm output

Alarm is issued with the switch in ON position,

and not in OFF position

Function setting

switch

Used to access preset

items in memory of the

Multi-Monitor and change

preset values.

Pressing SW1 indicates preset item number in

upper seven-segment display and current preset

value in lower. SW2 and SW3 select a new value

to replace existing value. Pressing SW4 registers

new value in memory.

Pressure display

lock switch

Change he incremental 뱓display?/ he locked 뱓display?

Pressing this switch indicates the flow rate in

upper seven-segment display and the light liquid

pressure in lower by fixed. IT is able to operate

on the Multi-Monitor panel.

Fig. 4-4

::::

Page 83: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-8

4.2.2 Principal Preset Items

Memory preset

item

Preset

item

No.

Description Unit Minimum

step of

adjustment

Setting

range

Standard

value

Factory

setting

Light liquid

pressure13

This is light liquid outlet

pressure. Pressure control LED

(yellow) on top of the

Multi-Monitor flashes when

actual light liquid outlet pressure

is within ± 15% of preset value

and is illuminated within ± 3%.

MPa 0.01

0.03

to

0.30

0.15 0.15

LM trigger

pressure (ΔP)5

Alarm trigger level is ΔP lower

than actual light liquid outlet

pressure. When actual light

liquid outlet pressure falls below

this level, an alarm is issued.

MPa 0.005

0.010

to

0.050

0.02 0.02

Minimum light

liquid pressure 4

This is the lower alarm limit level

of light liquid outlet pressure.

When actual light liquid outlet

pressure falls below this limit, an

alarm is issued.

MPa 0.01

0.03

to

0.30

0.12 0.12

Delay Timer 6

Alarm status is released as long

as set on delay timer until actual

light liquid outlet pressure is

stabilized after feed is started.

sec 5

5

to

120

40 40

Hold Timer 7

If actual light liquid outlet

pressure falls below alarm

trigger level or lower alarm

trigger limit during oil feed, alarm

status is released as long as set

on hold timer. When the timer is

up, an alarm is issued if pressure

is not back to normal. Timer

count is cleared if pressure is

back to normal within set time.

sec 5

5

to

120

15 15

NOTE

Set minimum light liquid pressure using the following as a guide.

[Minimum light liquid pressure] = [Light liquid pressure] ? [LM trigger pressure P] ? [A]

[A] = 0.01 to 0.02 MPa

Page 84: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-9

4.2.3 Light Liquid Outlet Pressure Adjustment

To ensure proper functioning of the Leakage Monitor, the

adjustment of light liquid outlet pressure to the light liquid

pressure level preset in the Multi-Monitor (memory preset

item No. 13) through back pressure control valve is required.

Carry out this adjustment as follows.

1. Accomplish pre-operational checks. (Refer to Section

5.1.4 nspections Prior to Running?) 밒2. Switch on the starter, automatic control panel (or alarm

panel) and Multi-Monitor in that order.

3. Set the MM function switch on the automatic control

panel (or alarm panel, starter panel) to ON and the LM

alarm output switch in Multi-Monitor to OFF.

4. Remove the front cover of the Multi-Monitor and check

that all internal switches are in the appropriate positions.

5. Start the oil purifier in accordance with the starting

procedure. Do not start feeding until the rated speed has

been reached.

6. While watching the flow rate display on the Multi-Monitor,

adjust the bypass valve and flow rate control valve for

the feed rate specified for the SELFJECTOR being operated. At the same time, fully open the back

pressure control valve (needle valve) at the light liquid outlet and record the pressure at that point

without fail.

7. Check that the feed liquid temperature is at the preset level through the feed liquid temperature

display on the Multi-Monitor. If lower, pressure drops when the feed liquid reaches the preset

temperature and an alarm is issued in some cases.

8. Press the pressure display lock switch on the panel (or the function setting switch SW1 in the

Multi-Monitor) to freeze the indications of flow rate and light liquid pressure in the upper and lower

seven-segment displays. While reading the light liquid pressure on the Multi-Monitor, accomplish

pressure adjustment to the level preset in the Multi-Monitor (refer to Section 4.2.2) through the

pressure control valve at the light liquid outlet.

9. Make fine adjustment of pressure through the back pressure control valve until the pressure control

LED (yellow) on top of the Multi-Monitor is illuminated. This LED flashes when pressure is within ±15% of the level preset in the Multi-Monitor and is illuminated within ± 3%.

10. After the adjustment of light liquid outlet pressure is completed, press the pressure display lock

switch on the panel (or the function setting switch SW1 in the Multi-Monitor) again to release the

pressure display locked status. Set the MM function switch on the automatic control panel to OFF

and then to ON. After that, the LM alarm output switch in Multi-Monitor to ON. Finally, reinstall the

front cover of the Multi-Monitor.

NOTE

For a period of approximately 20 to 30 seconds after the MM function switch on the automatic

control panel (or the alarm panel or starter) is set to ON from OFF, the LED displays of the

Multi-Monitor remain blank, which is a normal transient phenomenon.

In addition the manual SELFJECTOR version with no alarm panel has the MM function switch

installed on the starter.

Fig. 4-5

Page 85: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-10

! CAUTION

1. The level of "light liquid pressure" preset in the Multi-Monitor is the "measured pressure

recorded in 6" plus LM trigger pressure P (standard value: 0.02 MPa).

Be sure not to set it beyond 0.2 MPa (2.0 kgf/cm2). Setting beyond 0.2 MPa (2.0 kgf/cm

2) may

cause the light liquid to overflow the light liquid chamber. (Refer to Section 4.2.2.)

Standard value for setting "light liquid pressure" is 0.15 MPa (1.5 kgf/cm2) for fuel oil, and is

0.10 MPa (1.0 kgf/cm2) for lubricating oil.

2. The level of "minimum light liquid pressure" preset in the Multi-Monitor should be less than

the "light liquid pressure" mentioned above minus LM trigger pressure P.

This value must be higher than the "measured pressure recorded in 6." If it is equal to or lower

than the recorded level, the Leakage Monitor may fail to detect a leakage of treated oil properly.

Standard value for setting "minimum light liquid pressure" is as follows,

[Minimum light liquid pressure]

= [Light liquid pressure] ? [LM trigger pressure P] ? [0.01 to 0.02] (MPa)

NOTE

Normally, once adjusted at trial run, light liquid outlet pressure requires no further

adjustment unless there are fluctuations in flow rate and temperature.

During daily check, ascertain proper illumination of the pressure control LED (yellow) and

correct indication in the light liquid pressure on the Multi-Monitor.

LM trigger pressure follows up pressure fluctuations due to pulsations during operation.

Even if the pressure control LED (yellow) flashes, therefore, there is no particular need for

pressure adjustment.

4.2.4 Checking Timer Setting after Start of Feeding Always check that the following timer setting is correct after oil feed is started.

Delay timer Ascertain that the time from the start of feeding after sludge discharge to the arrival of discharge side pressure at preset level is shorter than the time preset on the delay timer.

NOTE1

Control fluctuations in the flow rate of feed liquid to the purifier to be within 0.01 MPa in

pressure equivalent.

NOTE2

Control feed liquid temperatures to be within 5% of preset level. Excessive fluctuations

change the feed liquid in viscosity to fluctuate light liquid outlet pressure as a result, possibly

affecting the output of the Leakage Monitor Function of the Multi-Monitor.

4.2.5 Pressure Adjustment after Feeding 1. Set the LM alarm output switch in Multi-Monitor to OFF. 2. Accomplish the steps 8 to 10 in Section 4.2.3 ight Liquid Outlet Pressure Adjustment?밚

Page 86: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-11

NOTE

The Discharge Detector Function (DD) of the Multi-Monitor is a protective device that relies on a

shaft speed drop to work. More specifically, if the horizontal shaft speed is not dropped during

sludge discharge, the detector detects it as a "No-Discharge" status by means of a proximity

switch. If the proximity switch is out of position or the switches are set wrong, a false alarm is

issued.

4.3.1 Setting Up the Discharge Detector Function

For the Discharge Detector Function, the Multi-Monitor is provided with a Partial ON/OFF switch for

monitoring sludge discharge among others, in addition to normal and abnormal speed indicating means.

Fig. 4-6 shows principal switches necessary for setting the Discharge Detector Function.

Fig. 4-6

Switch Function Remarks

Power switch ON/OFF control of Multi-Monitor power.

Power is turned on with the switch in ON position and off in OFF position.

DD alarm output switch

ON/OFF control of discharge alarm output.

An alarm is issued with the switch in ON position, and not in OFF position.

50Hz / 60Hz selector switch

Selection of power frequency between 50Hz and 60Hz.

Used to select appropriate power frequency for the SELFJECTOR between 50Hz and 60Hz.

Partial ON / OFF switch

Constant monitoring of partial charge for optimal quantity.

Constant monitoring is effected with the switch in ON position and stopped in OFF position. Whether or not partial discharge is optimal is indicated through partial discharge LEDs.

Dischargemeasurementswitch

A push button for effecting one-time measurement of discharged quantity during partial discharge.

Measurement is enabled only when partial ON/OFF switch is in OFF position. Whether or not partial discharge is optimal is indicated through partial discharge LEDs. This switch is mainly used for adjustments at trial run.

( )( )( ))

Page 87: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-12

4.3.2 Adjusting the Proximity Switch Position

! CAUTION

The Discharge Detector is precision equipment. Take special cares so that it is not bumped

during handling.

The proximity switch should be retained firmly with the screws.

(The fastening torque should be 60 kg cm or less.)

Make sure that the purifier is completely stopped before checking and adjusting, if

necessary, the installed position of the proximity switch.

Do not use a proximity switch other than supplied with the SELFJECTOR.

The proximity switch is screwed directly in the gear pump housing (horizontal shaft cover where

separate pump is used) and secured with a lock nut. To adjust the installed position of the proximity

switch, loosen the lock nut and set the proximity switch at a distance of 1.0 ± 0.3 mm from the

horizontal shaft. After the adjustment is finished, retighten the lock nut to secure the proximity switch.

(See Fig. 4-7.) The nut tightening torque should be less than 60 kg・cm.

Fig. 4-7

Page 88: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-13

4.3.3 Checking Proximity Switch Position

1. If the proximity switch is in position

The rotation display LED (green) on top of the Multi-Monitor flashes while the oil purifier is in

operation.

The rotation display LED (green) is illuminated when the oil purifier is stopped.

The speed appears in the appropriate seven-segment display.

2. If the proximity switch is out of position -

The trouble display LED (red) on top of the Multi-Monitor is lit when rated speed is reached.

Specifically, this LED is illuminated in either of the following cases.

(i) Input signal to the proximity switch is unstable - probable cause is the proximity switch being out of

position.

(ii) Proximity switch output exceeds 2,500 rpm in speed equivalent - probable cause is a circuit failure.

4.3.3.1 Measuring Proximity Switch Output Voltage

The installed position of the proximity switch can be accurately checked by measuring its output

voltage.

Open then cover of the Multi-Monitor and measure voltage

across between the test pins [GND (black) and [REV (red)]

shown in Fig. 4-8 using a tester.

Table 4-5 shows test pin voltages versus power frequencies

when the proximity switch is in position.

Check the measure voltage reference to the correct voltage.

Table 4-5

Frequency Voltage

60Hz Approx. DC3.5V

50Hz Approx. DC2.9V

NOTE

When the tester reading exceeds DC4V, a circuit failure is suspected. In such case, contact MKK

service shop or us nearest to you.

Fig. 4-8

( )( +)

Page 89: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-14

4.4 Water Detector Function (WD)

4.4.1 Setting Up the Water Detector Function

Described below is the pressure sensor type Water Detector (G-HIDENS system) incorporated in the

automatic control panel GSH-1/Multi-Monitor MM3 system configuration.

Fig. 4-9 shows principal switches necessary for setting the Water Detector Function of the

Multi-Monitor.

Fig. 4-9

Switch Function Remarks

Power switch ON/OFF control of Multi-Monitor power.

Power is turned on with the switch in ON position and off in OFF position.

Water detector selector dial

Selection between working and no working of Water Detector function.

Set the switch to working of the Water detector function in clarifier operation and to no working in purifier operation.

Water detection output switch

ON/OFF control of Water Detection output signal.

An output signal is issued with the switch in ON position, and not in OFF position.

Function setting switch

Used to access memory preset item in the Multi-Monitor and change preset value.

Pressing SW1 indicates the preset item number in upper seven-segment display and current preset value in lower. SW2 and SW3 select new preset value to replace existing value. Pressing SW4 registers new preset value in memory.

::::

Page 90: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-15

4.4.2 Principal Preset Items

Memory preset

item

Preset

item

No.

Description Unit Minimum

step of

adjustment

Setting

range

Standard

value

Factory

setting

Minimum WD

pressure10

This is the trigger level for

pressure sensor installed in

circulation line. When pressure

in circulation line falls below this

level, pressure sensor detects

accumulated water in bowl

having reached the predetermine

level and issues an output

signal.

MPa 0.01

0.01

to

0.10

0.03 0.03

WD trigger

pressure (ΔW)12

Water Detection trigger level is ΔW lower than actual circulation

line pressure. If actual circulation

line pressure falls below this

level, an alarm signal is issued.

MPa 0.005

0.01

to

0.10

0.05 0.05

4.4.3 Adjusting Circulation Line Back Pressure Valve

1. Set the MM function switch on the automatic control panel (GSH-1) to OFF.

2. Operating the function setting switches, check that preset Water Detection trigger pressure (ΔW:

memory preset item No. 12) and minimum water detection pressure (memory preset item No. 10)

are correct. If not, reset them.

3. Set the Water Detector selector dial to "Water detector function" position for working of the Water

Detector Function.

4. Reading the analog pressure gauge installed at the circulation line, adjust the circulation line back

pressure valve for a back pressure of 0.1 MPa (1.0 kgf/cm2).

5. After circulation line pressure adjustment is finished, return the MM function switch on the automatic

control panel (GSH-1) to ON to make the Water Detector Function operative. Finally, reinstall the

cover of the Multi-Monitor.

Fig. 4-10

Page 91: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual24-16

! CAUTION

To avoid the risk of feed liquid being scattered out from the chamber or the motor being

overloaded, be sure that the maximum circulation line back pressure is controlled by less than

0.15 MPa (1.5 kgf/cm2).

! CAUTION

Before operating the SELFJECTOR, make sure that the G-HIDENS gravity disc installed in the

bowl is suitable for its type. A wrong gravity disc may cause outflow of treated oil to the sludge

outlet or the motor being overloaded

.

4.4.4 Setting Up the Electrostatic Capacity Type Water Detector

1. When the electrostatic capacity type Water Detector is used, set the following switches in the

Multi-Monitor in respective positions.

(i) Water Detector selector dial: "No water / heavy liquid detector function" position

(ii) Water Detection output switch: "OFF"

2. Set [Water Detector] switch on the automatic control panel (GSH-1) to AUTO or MANUAL.

3. Press [Start Water Detector Control] push button to make the Water Detector ready for control.

! CAUTION

Do not operate the SELFJECTOR without installing necessary parts for clarifier operation in the

bowl first.

Lack of clarifier parts causes light liquid to flow out to the heavy liquid side.

Page 92: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-1

5 Operation

5.1 Inspections Prior to Running

! CAUTION

The purifier should be operated under optimum conditions to suit the nature of the treated oil.

For each purifier type or specification, there are design limits for flow rate, pressure,

temperature, etc. Operation beyond these limits could put the purifier in a dangerous state.

5.1.1 Pipe connections

Make sure that the oil pipes, operating water pipes, and air pipes are correctly laid and that the joints

are firmly tightened. (Refer to the attached document & drawing.)

NOTE

Check if the operating water pipes for opening/closing bowl are not connected the wrong

way, i.e. one for the other.

Make sure that a 60 to 100 meshes strainer is attached in front of the gear pump.

Make sure that a butterfly valve is mounted on the sludge outlet pipe.

5.1.2 Electrical wiring

Make sure that the wiring has been done correctly. (Refer to the attached document & drawing.)

5.1.3 Flushing

Flush the inside of pipes connected to the purifier (oil delivery, water supply and compressed air lines)

to completely remove foreign matters from them.

! CAUTION

If the purifier is re-started after an insufficient flushing, the following malfunctions may occur:

Damage to the gear pump and frequent breaks of the safety joint.

Damage to the main cylinder seat surface and the main seal ring.

Damage to the valve seat surface.

NOTE

Before flushing, disconnect the primary side connection flange from the operating water

pressure reducing valve to prevent ingress of water into the bowl from the water supplying

device during flushing.

Page 93: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-2

5.1.4 Inspections prior to running (confirmation)

! CAUTION

Always confirm the following subjects prior to running the purifier.

1. Make sure that an appropriate gravity disc has been employed in the bowl. (Refer to Section 3.3.)

2. Refill an appropriate type of lubrication oil in the gear case. This oil quantity should be confirmed

with the oil gauge.

3. Make sure that the primary pressure of compressed air supply pressure is between 0.5 and 0.9

MPa (5 to 9 kgf/cm2).

4. Open the source valve on the operating water pipe to make sure the pressure.

Automatic

configuration

Discharge mode Set pressure

(Standard value) Required operating

water pressure

Manual, GAP-11

GBC-1

Total discharge 0.3 MPa

(3 ㎏ f/cm2)

0.35 ~ 0.5 MPa

(3.5 ~ 5 ㎏ f/cm2)

GSH-1 Total discharge and

Partial discharge

0.25 MPa

(2.5 ㎏ f/cm2)

0.35 ~ 0.5MPa

(3.5 ~ 5 ㎏ f/cm2)

5. Either operate the solenoid valve or manually operate the respective valve to make sure that the

operating water for opening/closing bowl is properly flowing out. (Check before the bowl is installed,

with the operating water inlet pipe disconnected.)

6. Disconnect the sealing water pipe (steel pipe) and measure the quantity of the sealing water

and replacement water. (Refer to Section 3.6.5.)

7. Make sure that the brake is in the non-braking position.

8. Make sure that the purifier has been properly assembled with bolts completely tightened. (Refer to

Section 2.2 in the aintenance Manual?) 밠9. Make sure the direction of revolution.

Turn on the starter. Start the motor and stop it simultaneously (within 3 seconds) and check that

the rotating direction of the motor or horizontal shaft is the same as the arrow n the purifier frame.

10. In case of automatic specification, power on the control panel and make sure that the timer

setting value is appropriate. (Refer to Section 3.8.)

11. Set the power switch of the Multi-Monitor to ON, and check that all the switches in the Multi-Monitor

are in proper positions and necessary memory preset items/values are correctly set. (Refer to

Section 4 ulti-Monitor?) 밠12. Fully open the inlet valve, outlet valve, and by-pass valve of the oil pipe.

13. Open the butterfly valve at the sludge discharge outlet.

Page 94: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-3

! CAUTION

Before resuming operation after the bowl has been overhauled and reassembled, check to

ascertain the following.

1. Make sure that the cap nut tying the bowl and vertical shaft together is tightened firmly.

2. Make sure that the alignment marks (stamped 0) on the bowl meet.

(Refer to Section 2.2 in the aintenance manual?) 밠3. Assemble the bowl into the vertical shaft, check the height, and make sure that the bowl can be

easily rotated by hand.

4. Make sure that the joints and traps (frame cover) of the piping are firmly tightened.

(Refer to Section 2.2 in the aintenance manual?) 밠5. Make sure that the union nuts and cover nuts of the inlet pipe are firmly tightened.

(Refer to Section 2.2 in the aintenance manual?) 밠

Page 95: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-4

5.2 Start-Up

5.2.1 Precautions on start-up

! CAUTION

Prior to starting operation, always accomplish what is described in Section 5-1 nspections 밒밒밒밒Prior to Running?

Note the following points at the start-up.

Subject Measures

Operation sound When an abnormal sound is heard, immediately stop the operation and

inspect the purifier and identify the cause.

Vibration Vibration may temporarily occur just after start-up, however, this is not

an anomaly.

It will be reduced when the rated number of revolution is achieved.

At the rated number of revolution if the vibration is large, immediately stop

the operation and inspect the purifier and identify the cause.

If feed liquid is being supplied, discontinue it and stop the purifier

immediately without sludge discharged.

Start-up time Small-size (SJ10G/GH - SJ30G/GH) and medium and large-size

(SJ50G/GH - SJ150G/GH) purifiers respectively reach their rated speeds in

less than 5 minutes and less than 10 minutes with current stabilized at 50

to 70% of the rated level. If the purifier fails to reach its rated speed despite

the lapse of more than 10 minutes, stop it in accordance with given

stopping procedure and check the friction block.

5.3 Stop

5.3.1 Precautions on stop

As the bowl is retarded, the purifier may vibrate at certain low speeds. This is a transient phenomenon

and normal.

! WARNING

Before disassembling or checking, make sure that the purifier is completely stopped and turn

off the starter. A look at the gear pump safety joint or motor fan tells whether or not the purifier

is at a stop.

NOTE

For the inspection procedure refer to the "Maintenance manual".

Page 96: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-5

5.4 Automatic Specification (GBC-1)

Fig. 5-1

*1

Page 97: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-6

5.4.1 Start-up

Use the following procedure for start-up.

Step 1

Before start-up, make sure that the valves [V5, V6, V7, V8, V9, and V10] are fully open.

Step 2

Operation Check item

Set power switches of the starter, automatic

control panel and Multi-Monitor to ON in that order.

Make sure that power to the starter, automatic

control panel and Multi-Monitor is on.

Step 3

Operation Check item

Set the MM function switch on the control panel to

ON and the LM alarm output switch to OFF.

Always operate this switch as described when feed

liquid flow and light liquid outlet pressure become

necessary to adjust.

Step 4

Operation Check item

Depress the [START] button on the starter to start

up the purifier.

Make sure that the operation sound and vibration

are normal.

After the start-up make sure that the current value

falls within 50 to 70% of the rating.

NOTE

Refer to Table 4-3 in Section 4.1.4 the perating manual1? 밢밢밢밢Usually the rated number of revolution can be achieved 5 to 10 minutes following the start-up.

Step 5

Operation Check item

Start the oil heater. Make sure that the feed liquid is circulating in the

oil heater and heated up to the given temperature.

NOTE

Such as fuel oil A does not have to be heated.

Step 6

Operation Check item

Depress the [AUTO START] push button on the

automatic control panel.

Processes of [Opening bowl] ⇒ [replacement

water] ⇒ [Discharge] ⇒ [Sealing water] ⇒[Feeding] will advance in this order.

Confirm the discharge operation by the increase of

current reading or discharge sound.

Page 98: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-7

Step 7

Operation Check item

After making sure that the purifier-run enters,

regulate the by-pass valve V8 and flow control

valve V5 to a given feed rate.

Check that the flow rate displayed on the

Multi-Monitor is the predetermined value.

Make sure the pressure at the light liquid outlet

side when V6 is fully open.

After the feeding, make sure that no oil leaks out in

the sludge outlet side and heavy liquid outlet side.

NOTE

Always make sure the pressure at the light liquid outlet side when V6 is fully open. This is

necessary for Leakage Monitor Function adjustment of the Multi-Monitor.

When setting up the Leakage Monitor (LM), refer to Section 4.2 eakage Monitor Function? 밚밚밚밚Step 8

Operation Check item

Throttle down the pressure valve V6 for the light

liquid pressure level present in the Multi-Monitor.

Then, change the MM function switch on the

control panel from OFF to ON and following to set

the LM alarm output switch in the Multi-Monitor to

ON.

The pressure adjustment LED (green) on top of the

Multi-Monitor starts flashing when the pressure is

within ±15% of the set pressure, and changes to

continuous lighting when it is within ±3%.

NOTE

After the temperature of feed liquid being fed is stabilized (approximately 5 minutes), check

once again that the light liquid pressure is within 15% of the level present in the Multi-Monitor

(the pressure adjustment LED flashing or continuous lighting). Readjust the pressure, if

necessary, through V6 while watching the pressure adjustment LED.

! CAUTION

When adjusting the light liquid outlet pressure only after feeding to a level beyond LM trigger

pressure ( P), follow the procedure below. Failure to follow may cause a false alarm.

(i) Set the MM function switch on the control panel to OFF position.

(ii) Accomplish pressure adjustment.

(iii) Place the MM function switch on the control panel back into the ON position.

In addition, the flow rate indicating LED of the Multi-Monitor should be actuated approximately 20 to

30 seconds after the MM function switch is set to ON.

The procedure adjusting both flow rate and light liquid outlet pressure after feeding refers to the

steps 8 to 10 in Section 4.2.3 ight밚밚밚밚 Liquid Outlet Pressure Adjustment?

Step 9

Operation Check item

If the Multi-Monitor has the Discharge Detector

Function, set the DD alarm output switch in the

Multi-Monitor to ON.

Make sure that the Rotation display LED (green)

on top of the Multi-Monitor is flashing. Make sure

that the Trouble display LED (red) turns off.

NOTE (MM-2:Optional specification)

If the rotation display LED (green) does not flash or the trouble display LED (red) is lighting, the

sensor out of position or a sensor circuit failure is probable cause. Take appropriate action in

accordance with Section 4.3.3 in this manual or Section 6.12.5 in the Maintenance Manual.

Page 99: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-8

5.4.2 Stop

! WARNING

When an unusually large vibration or sound (contact sound or abnormal sound from the

bearing section) is present, stop the purifier as soon as possible by depressing the

"Emergency Stop" push button.

Stop the purifier with the following procedure.

Step 1

Operation Check item

Depress the [AUTO STOP] push button on the

automatic control panel.

The feed liquid valve CV1 closes and the

sequential process of [Replacement] ⇒[Discharge] ⇒ [Stop] automatically follows.

Confirm the discharge operation by the increase of

current reading and discharge sound.

Step 2

Operation Check item

Stop the oil heater.

Step 3

Operation Check item

After making sure that the SELFJECTOR

completely stops, close both the feed liquid inlet

valve V7 and butterfly valve V10.

Also make sure that the other valves and cocks are

closed.

NOTE

Whether the SELFJECTOR stops or not can be confirmed with either the safety joint at the

horizontal shaft gear pump or the motor fan.

As the Discharge Detector Function is included in the MM-2 system, the rotation display LED

(green) on top of the Multi-Motor changes from flashing to constant lighting to tell that the

SELFJECTOR has been stopped.

Step 4

Operation Check item

Set power switches of the Multi-Monitor, automatic

control panel and starter to OFF in that order.

Make sure that power to the Multi-Monitor,

automatic control panel and starter has been cut

off.

Page 100: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-9

5.5 Automatic Specification (GSH-1)

Fig. 5-2

Page 101: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-10

5.5.1 Start-up

Use the following procedure for start-up.

Step 1

Before start-up, make sure that the valves [V5, V6, V7, V8, V9, V10 and V11] are fully open and that

the valve V12 is fully closed.

Prior to clarifier operation with the G-HIDENS type SELFJECTOR, make sure that the valve V12 is fully

open and the valve V11 is fully closed.

Step 2

Operation Check item

Set power switches of the starter, automatic

control panel and Multi-Monitor to ON in that order.

Make sure that power to the starter, automatic

control panel and Multi-Monitor is on.

Step 3

Operation Check item

Set the MM function switch on the control panel to

ON. Then set the LM alarm output switch and

water detection output switch in the Multi-Monitor

to OFF.

Always operate this switch as described when feed

liquid flow and light liquid outlet pressure become

necessary to adjust.

Step 4

Operation Check item

Depress the [START] button on the starter to start

up the purifier.

Make sure that the operation sound and vibration

are normal.

After the start-up make sure that the current value

falls within 50 to 70% of the rating.

NOTE

Refer to Section 4.1.4 Table 4-3 in the perating manual1? 밢밢밢밢Usually the rated number of revolution can be achieved 5 to 10 minutes following the start-up.

Step 5

Operation Check item

Start the oil heater. Make sure that the feed liquid is circulating in the

oil heater and heated up to the given temperature.

Step 6

Operation Check item

Depress the [AUTO START] push button on the

automatic control panel.

Processes of [Closing bowl] ⇒ [replacement

water] ⇒ [Discharge] ⇒ [Sealing water] ⇒[Feeding] will advance in this order.

Confirm the discharge operation by the increase of

current reading or discharge sound.

Page 102: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-11

Step 7

Operation Check item

After making sure that the purifier-run enters,

regulate the by-pass valve V8 and flow control

valve V5 to a given feed rate.

Check that the flow rate displayed on the

Multi-Monitor is the predetermined value.

Make sure the pressure at the light liquid outlet

side when V6 is fully open.

After the feeding, make sure that no oil leaks out

in the sludge outlet side and heavy liquid outlet

side.

NOTE

Always make sure the pressure at the light liquid outlet side when V6 is fully open. This is

necessary for Leakage Monitor Function adjustment of the Multi-Monitor.

When setting up the Leakage Monitor (LM), refer to Section 4.2 eakage Monitor Function? 밚밚밚밚Step 8

Operation Check item

Throttle down the pressure valve V6 for the light

liquid pressure level present in the Multi-Monitor.

The pressure adjustment LED (green) on top of the

Multi-Monitor starts flashing when the pressure is

within ±15% of the set pressure, and changes to

continuous lighting when it is within ±3%.

NOTE

After the temperature of feed liquid being fed is stabilized (approximately 5 minutes), check

once again that the light liquid pressure is within 15% of the level present in the Multi-Monitor

(the pressure adjustment LED flashing or continuous lighting). Readjust the pressure, if

necessary, through V6 while watching the pressure adjustment LED.

Step 9

Operation Check item

Adjust the circulation line pressure to 0.1 MPa (1.0

kgf/cm2) through the circulation line back pressure

valve V12.

Set the water detector selector dial in the

Multi-Monitor to working of the water detector

position, and change the MM function switch on

the control panel from OFF to ON. And then set

the LM alarm output switch and water detection

output switch in the Multi-Monitor to ON,

Check that adjusted pressure is correct on the

analog pressure gauge installed on the circulation

line (lower hood of the frame).

Page 103: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-12

! CAUTION

When adjusting the light liquid outlet pressure only after feeding to a level beyond LM trigger

pressure ( P), follow the procedure below. Failure to follow may cause a false alarm.

(i) Set the MM function switch on the control panel to OFF position.

(ii) Accomplish pressure adjustment.

(iii) Place the MM function switch on the control panel back into the ON position.

In addition, the flow rate indicating LED of the Multi-Monitor should be actuated approximately 20 to

30 seconds after the MM function switch is set to ON.

The procedure adjusting both flow rate and light liquid outlet pressure after feeding refers to the

steps 8 to 10 in Section 4.2.3 ight밚밚밚밚 Liquid Outlet Pressure Adjustment?

! CAUTION

Setting the circulation line pressure beyond 0.15 MPa (1.5 kgf/cm2) could result in the light liquid

flowing out to the sludge side or the motor being overloaded.

! CAUTION

When adjusting the circulation line pressure to a level beyond the WD trigger pressure, follow

the procedure below. Failure to follow may cause a false alarm.

(i) Set the MM function switch on the control panel to OFF position.

(ii) Accomplish pressure adjustment.

(iii) Place the MM function switch on the control panel back into the ON position.

In addition, the flow rate indicating LED of the Multi-Monitor should be actuated approximately 20 to

30 seconds after the MM function switch is set to ON.

Step 10

Operation Check item

Set the DD alarm output switch in the Multi-Monitor

to ON.

Make sure that the Rotation display LED (green)

on top of the Multi-Monitor is flashing.

Make sure that the Trouble display LED (red)

turns off.

NOTE

If the rotation display LED (green) does not flash or the trouble display LED (red) is lighting, the

sensor out of position or a sensor circuit failure is probable cause. Take appropriate action in

accordance with Section 4.3.3 in this manual or Section 6.12.5 in the Maintenance Manual.

Page 104: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-13

5.5.2 Stop

! WARNING

When an unusually large vibration or sound (contact sound or abnormal sound from the

bearing section) is present, stop the purifier as soon as possible by depressing the

"Emergency Stop" push button.

Stop the purifier with the following procedure.

Step 1

Operation Check item

Depress the [AUTO STOP] push button on the

automatic control panel.

The feed liquid valve CV1 closes and the

sequential process of [Replacement] ⇒[Discharge] ⇒ [Stop] automatically follows.

Confirm the discharge operation by the increase of

current reading and discharge sound.

Step 2

Operation Check item

Stop the oil heater.

Step 3

Operation Check item

After making sure that the SELFJECTOR

completely stops, close both the feed liquid inlet

valve V7 and butterfly valve V10.

Also make sure that the other valves and cocks

are closed.

NOTE

Whether the SELFJECTOR stops or not can be confirmed with either the safety joint at the

horizontal shaft gear pump or the motor fan.

As the Discharge Detector Function is included in the MM-3 system, the rotation display LED

(green) on top of the Multi-Motor changes from flashing to constant lighting to tell that the

SELFJECTOR has been stopped.

Step 4

Operation Check item

Set power switches of the Multi-Monitor, automatic

control panel and starter to OFF in that order.

Make sure that power to the Multi-Monitor,

automatic control panel and starter has been cut

off.

Page 105: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-14

5.6 Manual Specification (GAP-11)

Fig. 5-3

Page 106: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-15

5.6.1 Start-up

Use the following procedure for start-up.

Step 1

Before start-up, make sure that the valves take the following positions:

Full open: V5, V6, V7, V8, V9, and V10

Full close: V1, V3, CV1 and SV2

Step 2

Operation Check item

Set power switches of the starter, alarm panel and

Multi-Monitor to ON in that order.

Make sure that power to the starter, alarm panel

and Multi-Monitor is on.

Step 3

Operation Check item

Set the MM function switch on the alarm panel to

ON. Then set the LM alarm output switch in the

Multi-Monitor to OFF.

Always operate this switch as described when feed

liquid flow and light liquid outlet pressure become

necessary to adjust.

Step 4

Operation Check item

Depress the [START] button on the starter to start

up the purifier. Set the MM function switch on the

control panel to ON.

Make sure that the operation sound and vibration

are normal.

After the start-up make sure that the current value

falls within 50 to 70% of the rating.

NOTE

Refer to Section 4.1.4 Table 4-3 in the perating manual1? 밢밢밢밢Usually the rated number of revolution can be achieved 5 to 10 minutes following the start-up.

Step 5

Operation Check item

Start the oil heater. Make sure that the feed liquid is circulating in the

oil heater and heated up to the given temperature.

NOTE

Such as fuel oil A does not have to be heated.

Step 6

Operation Check item

Open the manual handle of the solenoid valve

SV2

for 20 to 30 seconds to supply the operating water

for closing bowl so that it is closed.

When the supply of operating water for closing

bowl is completed, close the manual handle of

the valve.

Page 107: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-16

Step 7

Operation Check item

Fill the measuring hopper with a specified quantity

of pure water, and open the globe valve V3 to

refill the bowl (supply of replacement water).

When the refill is completed, always make sure

that V3 is closed.

NOTE

The inside surface of the measuring hopper has a mark to show the quantity.

For the necessary quantity of replacement water, refer to Table 3-12 in Section 3.6.5.1.

Step 8

Operation Check item

Open the cock (for opening bowl) V1 for

approximately 2 seconds to supply the operating

water for opening bowl so that water in the bowl

(replacement water) is discharged.

Confirm the discharge operation by the increase of

current reading or discharge sound.

NOTE

Perform flushing inside the bowl.

Step 9

Operation Check item

When the discharge is completed, close the cock

V1 and open the solenoid valve SV2 for 20 to 30

seconds to supply the operating water for closing

bowl.

Step 10

Operation Check item

Refill the bowl with a specified quantity of pure

water using the hopper (supply of sealing water).

When the refill is completed, always make sure

that V3 is closed.

NOTE

Same as above step 7.

For the necessary quantity of sealing water, refer to Table 3-12 in 3.6.5.1.

Step 11

Operation Check item

Depress the [FEEDING] push button.

Page 108: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-17

Step 12

Operation Check item

Regulate the flow control valve V5 and by-pass

valve V8 to a given feed rate.

Check that the flow rate displayed on the

Multi-Monitor is the predetermined value.

Make sure the pressure at the light liquid outlet

side when V6 is fully open.

After the feeding, make sure that no oil leaks out

in the sludge outlet side and heavy liquid outlet

side.

NOTE

Always make sure the pressure at the light liquid outlet side when V6 is fully open. This is

necessary for Leakage Monitor Function adjustment of the Multi-Monitor.

When setting up the Leakage Monitor (LM), refer to Section 4.2 eakage Monitor Function? 밚밚밚밚Step 13

Operation Check item

Throttle down the pressure valve V6 for the light

liquid pressure level present in the Multi-Monitor.

Then, change the MM function switch on the alarm

panel from OFF to ON, and following to set the LM

alarm output switch in the Multi-Monitor to ON.

The pressure adjustment LED (green) on top of the

Multi-Monitor starts flashing when the pressure is

within ±15% of the set pressure, and changes to

continuous lighting when it is within ±3%.

NOTE

After the temperature of feed liquid being fed is stabilized (approximately 5 minutes), check

once again that the light liquid pressure is within 15% of the level present in the Multi-Monitor

(the pressure adjustment LED flashing or continuous lighting). Readjust the pressure, if

necessary, through V6 while watching the pressure adjustment LED.

! CAUTION

When adjusting the light liquid outlet pressure only after feeding to a level beyond LM trigger

pressure ( P), follow the procedure below. Failure to follow may cause a false alarm.

(i) Set the MM function switch on the alarm panel to OFF position.

(ii) Accomplish pressure adjustment.

(iii) Place the MM function switch on the alarm panel back into the ON position.

In addition, the flow rate indicating LED of the Multi-Monitor should be actuated approximately 20 to

30 seconds after the MM function switch is set to ON.

The procedure adjusting both flow rate and light liquid outlet pressure after feeding refers to the

steps 8 to 10 in Section 4.2.3 ight밚밚밚밚 Liquid Outlet Pressure Adjustment?

Page 109: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-18

Sludge discharge procedure

To have sludge discharge effected during feeding operation;

1. Depress the [STOP FEEDING] push button on the alarm panel to stop oil feed to the purifier.

2. Accomplish Steps 7, 8 and 9 to let sludge discharge take place.

3. Then, accomplish Steps 10 and 11 to resume feeding operation.

! CAUTION

In the lubricating oil treatment, introduce washing water into the bowl to clean at intervals of 6

to 8 hours before sludge discharge operation. (Carry out according to the operation procedure

for sludge discharge.) The bowl washing process is carried out after sludge discharge. For

necessary quantity of washing water, refer to Table 3-14 in Section 3.6.6.

Failure to clean the bowl may affect the purifier's performance or cause mechanical troubles.

Page 110: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-19

5.6.2 Stop

! WARNING

When an unusually large vibration or sound (contact sound or abnormal sound from the bearing

section) is present, stop the purifier as soon as possible by first depressing the "STOP

FEEDING" push button, then depressing the [Stop] push button on the starter.

Stop the purifier with the following procedure.

Step 1

Operation Check item

Depress the [STOP FEEDING] push button on the

alarm panel to close the feed valve CV1.

Step 2

Operation Check item

Stop the oil heater.

Step 3

Operation Check item

Fill the measuring hopper with a specified quantity

of water, and open the globe valve V3 to refill the

bowl (supply of replacement water).

When the refill is completed, always make sure

that V3 is closed.

NOTE

For the necessary quantity of replacement water, refer to Table 3-12 in Section 3.6.5.1.

Step 4

Operation Check item

Open the cock V1 for approximately 2 seconds to

discharge the sludge.

Confirm the discharge operation by the increase of

current reading or discharge sound.

Step 5

Operation Check item

Depress the [STOP] push button of the starter to

stop the motor.

Page 111: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-20

Step 6

Operation Check item

After making sure that the SELFJECTOR

completely stops, close both the feed liquid inlet

valve V7 and butterfly valve V10.

Also make sure that the other valves and cocks

are closed.

NOTE

Whether the SELFJECTOR stops or not can be confirmed with either the safety joint at the

horizontal shaft gear pump or the motor fan.

Step 7

Operation Check item

Set power switches of the Multi-Monitor, alarm

panel and starter to OFF in that order.

Make sure that power to the Multi-Monitor, alarm

panel and starter has been cut off.

Page 112: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-21

5.7 Manual Specification

Fig. 5-4

Page 113: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-22

5.7.1 Start-up

Use the following procedure for start-up.

Step 1

Before start-up, make sure that the valves take the following positions:

Full open: V4, V6, V7, V8, V9 and V10

Full close: V1, V3, V5 and SV2

Step 2

Operation Check item

Set the MM function switch on the starter panel

and the LM alarm output switch in the Multi-Monitor

to OFF.

Always operate this switch as described when feed

liquid flow and light liquid outlet pressure become

necessary to adjust.

Step 3

Operation Check item

Set power switches of the starter, and

Multi-Monitor to ON in that order.

Make sure that power to the starter, and

Multi-Monitor is on.

Step 4

Operation Check item

Depress the [START] button on the starter to start

up the purifier.

Make sure that the operation sound and vibration

are normal.

After the start-up make sure that the current value

falls within 50 to 70% of the rating.

NOTE

Refer to Section 4.1.4 Table 4-3 in the perating manual1? 밢밢밢밢Usually the rated number of revolution can be achieved 5 to 10 minutes following the start-up.

Step 5

Operation Check item

Start the oil heater. Make sure that the feed liquid is circulating in the

oil heater and heated up to the given temperature.

NOTE

Such as fuel oil A does not have to be heated.

Step 6

Operation Check item

Open the manual handle of the solenoid valve

SV2

for 20 to 30 seconds to supply the operating water

for closing bowl so that it is closed.

Page 114: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-23

Step 7

Operation Check item

Fill the measuring hopper with a specified quantity

of pure water, and open the globe valve V3 to

refill the bowl (supply of replacement water).

When the refill is completed, always make sure

that V3 is closed.

NOTE

The inside surface of the measuring hopper has a mark to show the quantity.

For the necessary quantity of replacement water, refer to Table 3-12 in Section 3.6.5.1.

Step 8

Operation Check item

Open the cock (for opening bowl) V1 to supply the

operating water for opening bowl so that water in

the bowl (replacement water) is discharged.

Confirm the discharge operation by the increase of

current reading or discharge sound.

NOTE

Perform flushing inside the bowl.

Step 9

Operation Check item

When the discharge is completed, close the cock

V1 and open the solenoid valve SV2 for 20 to 30

seconds to supply the operating water for closing

bowl.

Step 10

Operation Check item

Refill the bowl with a specified quantity of pure

water using the hopper (supply of sealing water).

When the refill is completed, always make sure

that V3 is closed.

NOTE

Same as above step 7.

For the necessary quantity of sealing water, refer to Table 3-12 in Section 3.6.5.1.

Step 11

Operation Check item

Open flow control valve V5 fully and then set the

MM function switch on the starter panel to ON.

After it, gradually open the feed liquid inlet valve

V7 for feeding.

Make sure that the by-pass valve V8 is fully open.

Page 115: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-24

Step 12

Operation Check item

After the feeding, close the glove valve for return

V4, regulate the by-pass valve V8 and feed control

valve V5 to a given feed rate.

Check that the flow rate displayed on the

Multi-Monitor is the predetermined value.

Make sure the pressure at the light liquid outlet

side when V6 is fully open.

After the feeding, make sure that no oil leaks

out in the sludge outlet side and heavy liquid

outlet side.

NOTE

Always make sure the pressure at the light liquid outlet side when V6 is fully open. This is

necessary for Leakage Monitor Function adjustment of the Multi-Monitor.

When setting up the Leakage Monitor (LM), refer to Section 4.2 eakage Monitor Function? 밚밚밚밚Step 13

Operation Check item

Throttle down the pressure valve V6 for the light

liquid pressure level present in the Multi-Monitor.

The pressure adjustment LED (green) on top of the

Multi-Monitor starts flashing when the pressure is

within ±15% of the set pressure, and changes to

continuous lighting when it is within ±3%.

NOTE

After the temperature of feed liquid being fed is stabilized (approximately 5 minutes), check

once again that the light liquid pressure is within 15% of the level present in the Multi-Monitor

(the pressure adjustment LED flashing or continuous lighting). Readjust the pressure, if

necessary, through V6 while watching the pressure adjustment LED.

Step 14

Operation Check item

Change the MM function switch on the starter

panel from OFF to ON, and then set the LM alarm

output switch in the Multi-Monitor to ON.

The MM function switch in the ON position causes

a FEED signal to be issued from the starter to the

Multi-Monitor, making the Leakage Monitor

operative.

! CAUTION

When adjusting the light liquid outlet pressure only after feeding to a level beyond LM trigger

pressure ( P), follow the procedure below. Failure to follow may cause a false alarm.

(i) Set the MM function switch on the starter panel to OFF position.

(ii) Accomplish pressure adjustment.

(iii) Place the MM function switch on the starter panel back into the ON position.

In addition, the flow rate indicating LED of the Multi-Monitor should be actuated approximately 20 to

30 seconds after the MM function switch is set to ON.

The procedure adjusting both flow rate and light liquid outlet pressure after feeding refers to the

steps 8 to 10 in Section 4.2.3 ight밚밚밚밚 Liquid Outlet Pressure Adjustment?

Page 116: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-25

Sludge discharge procedure

To have sludge discharge effected during feeding operation;

1. Set the MM function switch on the starter panel to OFF to make the Leakage Monitor

Function of the Multi-Monitor inoperative.

2. Open the circulation valve V4 and close the feed liquid inlet valve V5 to stop oil feed to the

oil purifier.

3. Accomplish Steps 7, 8 and 9 to let sludge discharge take place.

4. Then, accomplish Steps 10, 11 and 12 to resume oil feeding.

In order to prevent an incorrect alarm, please carry out operation of Procedure 12 within 40

seconds after setting the MM functional switch to ON.

! CAUTION

In the lubricating oil treatment, introduce washing water into the bowl to clean at intervals of 6

to 8 hours before sludge discharge operation. (Carry out according to the operation procedure

for sludge discharge.) The bowl washing process is carried out after sludge discharge. For

necessary quantity of washing water, refer to Table 3-14 in Section 3.6.6.

Failure to clean the bowl may affect the purifier's performance or cause mechanical troubles.

Page 117: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-26

5.7.2 Stop

! WARNING

When an unusually large vibration or sound (contact sound or abnormal sound from the

bearing section) is present, shut off the supply of feed liquid, then immediately depress the

[Stop] button on the starter to stop the purifier.

Stop the purifier with the following procedure.

Step 1

Operation Check item

Set the MM function switch on the starter panel to

OFF.

Step 2

Operation Check item

Stop the oil heater.

Step 3

Operation Check item

After fully open the glove valve for return V4 and

by-pass valve V8, close the feed liquid inlet valve

V7.

Step 4

Operation Check item

Fill the measuring hopper with a specified quantity

of water, and open the globe valve V3 to refill the

bowl (supply of replacement water).

When the refill is completed, always make sure

that V3 is closed.

NOTE

For the necessary quantity of replacement water, refer to Table 3-12 in Section 3.6.5.1.

Step 5

Operation Check item

Open the cock V1 for approximately 2 seconds to

discharge the sludge.

After this discharge, close cock V1.

Confirm the discharge operation by the increase of

current reading or discharge sound.

Step 6

Operation Check item

Depress the [STOP] push button of the starter to

stop the motor.

Page 118: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual25-27

Step 7

Operation Check item

After making sure that the SELFJECTOR

completely stops, close both the feed liquid inlet

valve V7 and butterfly valve V10.

Also make sure that the other valves and cocks

are closed.

NOTE

Whether the SELFJECTOR stops or not can be confirmed with either the safety joint at the

horizontal shaft gear pump or the motor fan.

Step 8

Operation Check item

Set power switches of the Multi-Monitor, and starter

to OFF in that order.

Make sure that power to the Multi-Monitor, and

starter has been cut off.

Page 119: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual26-1

6 Suspension

If the oil purifier will not be used for a long period of time (more than 3 months) carry out the following

inspection, maintenance and service activities.

6.1 Preparations for Suspension

1. The frame and sludge cover should be disassembled for cleaning. After completely removing

moisture, apply rust-preventive oil all over the inside surface.

2. After disassembling and cleaning, the bowl should be applied lubricating oil, then re-assembled.

Apply rust-preventive oil on the outside surface of the bowl, and store it separately without

re-assembling in the vertical shaft.

3. The vertical and horizontal shafts should be disassembled for cleaning. After cleaning, apply

rust-preventive oil all over the surface, then re-assemble them in the purifier main body.

4. The inside surface of the gear case should be applied rust-preventive oil after cleaning. Do not refill

lubricating oil before starting operation.

5. After disassembling and cleaning, the gear pump should be applied lubricating oil, then

re-assembled. Accumulated oil, if present in the pump connecting tube, should be completely

removed in advance so that it from does not flow into the gear pump.

6. Close the source valve of the operating water pipe, then drain water from the pipe and open the

flange.

7. Place appropriate desiccant in the Multi-Monitor.

! CAUTION

Place appropriate desiccant in the starter, control panel and Multi-Monitor and wrap them

closely in vinyl film sheet or the like. Condensation due to significant moisture may cause

rust inside. Close the butterfly valve at the sludge outlet.

Shut the butterfly valve. If the butterfly valve is open during suspension, vapors from the

sludge tank may cause the shaft system to be oxidized.

Page 120: Operation Manual 2-Samgong

SELFJECTOR Instruction Manual Operation Manual26-2

6.2 Maintenance during Suspension

6.2.1 Purifier main body and mechanical components

Carry out the turning of the vertical shaft for 2 or 3 minutes by hand at least once a week.

Carry out quarterly inspections, centering on the bearing section, to make sure of freedom

from rust.

Carry out the 6-month periodical inspection and execute the rust prevention measures.

6.2.2 Electrical component

Carry out the 6-month periodical inspection and replace desiccants, then perform complete seal-up.

6.3 Resuming Operation

Before resuming the operation, carry out inspections according to 5.1.4 Inspections prior to running?

On the electrical components perform insulation checks on each terminal and coil to make sure they

have a dielectric resistance 1 MΩ or greater.

6.4 Other

! CAUTION

When the purifier has not been used for a long period of time (more than 3 months), carry out

inspections centering on the bearing section prior to resuming the operation.

Check that the bearings are all rust-free.

Be sure to replace rusted bearings.

Be sure to oil the bearings before starting the operation.

Page 121: Operation Manual 2-Samgong

SAMGONG-MITSUBISHI

SELFJECTOR

GENIUS SERIES

INSTRUCTION MANUAL

(OPERATION MANUAL 2)

Date of Issued : June 2004

SAMGONG CO., LTD.