operator disassembly - doorking...dr i ve ar m l i nking ar m arm assembly install the gate...

1
Drive Arm Linking Arm Arm Assembly Install the gate attachment bracket to gate. Lockpin Lockpin Retaining Ring Spacing Washers QUICKSTART “BASIC” GUIDELINES FOR MODEL 6004 - FOR GATES UP TO 8 FEET, 300LBS AND “OPENING TO THE INSIDE” Copyright 2018 DoorKing, Inc. All rights reserved. Thru-Bolt Note: The mounting bracket and motor can be flipped for right-side opening direction. Remove cover and 2 thru-bolts to remove and install the mounting bracket. Note: Lock and unlock directions will be reversed when motor is in the right-side orientation. Manual Release Right-Side Orientation Left-Side Orientation DOORKING Motor Cover Mounting Bracket Note: Linking arm must be in the center hole of the gate attachment bracket. Opens to the Inside Position of Operator and Arms Operator Disassembly Installing Mounting Bracket and Gate Attachment Bracket C B A 90° Linking Arm “A” inches “B” inches C max. inches Gate Attachment Bracket 2.50 - 4.25 4.25 - 6.25 6.25 - 8.25 8.25 - 10.25 10.25 - 12.25 12.25 - 14.00 28.75 28.25 28.00 27.25 27.00 26.25 4.25 - 5.00 4.25 - 5.00 4.25 - 5.00 4.25 - 5.00 4.25 - 5.00 4.25 - 5.00 DOORKING DOORKING DOORKING Support Bar must be used if the operator is mounted in the middle of the gate and span the entire length of the gate to support the gate pickets. The pickets will bend if not supported. Top Middle Bottom Left-Side Position Right-Side Position Coaxial Cable Antenna (Not Supplied) Operator Cable Power Loops Unlock Lock Unlock Lock Mounting Options Attach mounting bracket to pilaster or wall with four (4) #10 screws and suitable expansion hardware (Not supplied). Left-Side “Bottom” Position shown. 1 5/8” Brackets MUST be installed level! Weld gate attachment bracket to gate or use two (2) suitable screws (Not supplied). Brackets MUST be securely attached. Extreme force will be exerted on brackets during normal gate cycling. 120 S. Glasgow Avenue Inglewood, California 90301 U.S.A. Limit Switch Adjustment Limit LEDs Slow Down LEDs Circuit board power must be ON when adjusting the limit rings, LEDs will light while turning the limit rings. 4302 4302 Arms MUST be installed level! 6004-066-G-8-18 Brown wire Blue wire Orange wire Red wire Yellow wire Green wire Green/Yellow wire NOT USED 7-Wire Operator Cable 5” or less 21” Typical 27.5” Max Photo Sensors Height Close Beam Open Beam Open Beam Close Beam Reversing Edge Photo Sensor Photo Sensor Sensor mounted just below actuator arm cable. Gate Opened Gate Closed Outside Property Inside Property Single operator connects to PRIMARY connection ONLY on the 115 VAC OR Solar control box circuit board. 1 7 8 6 5 4 3 2 PRIMARY 4302 The 6004 is intended for installation only on swing gates used for vehicles. Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to 6004 Actuator Arm and Control Box Mounting manual, 115 VAC or Solar Control Box Wiring/Owner’s manuals. THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. Visit www.dkslocator.com to find a professional installing and servicing dealer in your area. Gate Closed Left-Side Right-Side Securely mount a control box near the actuator arm with appropriate hardware (not supplied). Control Box 115 VAC or Solar Power Input Opening Direction DIP-Switch 1 (SW 1) Refer to YOUR chosen 115 VAC OR Solar powered control box manuals for complete DIP-switch settings. DO NOT cycle operator before limit switches and DIP-switches have been adjusted, damage could occur to gate and operator. Limit Slow Down Slow Down Limit Top Limit Ring Bottom Limit Ring Slow Down Thru-Bolt Thru-Bolt Manually move the gate to the desired open or closed position. Loosen the limit screws and slowly rotate the limit rings until the LIMIT LEDs on the circuit board light up. Reversing Edge is mounted along ENTIRE end of gate. Wiring to Circuit Board Potential Entrapment Area Factory wired jumpers MUST be removed. Note: Only 1 monitored Device can be connected for each cycling direction. An OPTIONAL Expansion Kit (sold separately) will allow connection for additional devices. Refer to YOUR chosen 115 VAC OR Solar powered control box manuals to wire entrapment protection devices. Open to the Outside - Refer to 6004 manual “Open to the Inside” Installation Note: Refer to 6004 manual for “Open to the Outside” installation. Open to the Inside The operator MUST OPEN GATE upon initial power up and OPEN command. If the operator closes gate after giving open command, shut off power and reverse this switch setting otherwise operator will NOT function correctly. External Entrapment Protection Devices Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists. The operator will not run without one or more monitored type B1 or B2 entrapment protection devices in EACH entrapment area. UL 325 August 2018 Standard

Upload: others

Post on 26-Mar-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Operator Disassembly - Doorking...Dr i ve Ar m L i nking Ar m Arm Assembly Install the gate attachment bracket to gate. Lockpin Lockpin Retaining Ring Spacing Washers QUICKSTART “BASIC”

Drive Arm

Linking Arm

Arm AssemblyInstall the gate attachment bracket to gate.

LockpinLockpin

Retaining Ring

SpacingWashers

QUICKSTART “BASIC” GUIDELINES FOR MODEL 6004 - FOR GATES UP TO 8 FEET, 300LBS AND “OPENING TO THE INSIDE”

Copyright 2018 DoorKing, Inc. All rights reserved.

Thru

-Bol

t

Note: The mounting bracket and motor can be flipped for right-side opening direction.

Remove cover and 2 thru-bolts to remove and install the mounting bracket.

Note: Lock and unlock directions will be reversed when motor is in the right-side orientation.

Manual Release

Right-Side Orientation

Left-Side Orientation

DO

OR

KI N

G

Motor

Cover

MountingBracket

Note: Linking arm must be in the center hole of the gate attachment bracket.

Opens to theInside

Position of Operator and Arms

OperatorDisassembly

Installing Mounting Bracket and Gate Attachment Bracket

1234567

1234567

CB

A

90°

Linking Arm

“A” inches “B” inches C max. inchesGate Attachment Bracket

2.50 - 4.25

4.25 - 6.25

6.25 - 8.25

8.25 - 10.25

10.25 - 12.25

12.25 - 14.00

28.75

28.25

28.00

27.25

27.00

26.25

4.25 - 5.00

4.25 - 5.00

4.25 - 5.00

4.25 - 5.00

4.25 - 5.00

4.25 - 5.00

D O O R K I N G

D O O R K I N G

D O O R K I N G

Support Bar must be used if the operator is mounted in the middle of the gate and span the entire length of the gate to support the gate pickets. The pickets will bend if not supported.

Top

Middle

Bottom

Left-Side Position Right-Side Position

CoaxialCableAntenna(NotSupplied)

OperatorCable

Pow

er

Loop

s

UnlockLock

Unlock

Lock

Mounting Options

Attach mounting bracket to pilaster or wall with four (4) #10 screws and suitable expansion hardware (Not supplied).

Left-Side“Bottom”Positionshown.

1 5/8”

Brackets MUST beinstalled level!

Weld gate attachment bracket to gate or use two (2) suitable screws (Not supplied).

Brackets MUST be securely attached. Extreme force will be exerted on

brackets during normal gate cycling.

120 S. Glasgow AvenueInglewood, California 90301

U.S.A.

Limit Switch AdjustmentLimit LEDs

Slow Down LEDs

Circuit board power must be ON when adjusting the limit rings, LEDs will light while turning the limit rings.

4302

4302

Arms MUST beinstalled level!

6004-066-G-8-18

Brown wire

Blue wire

Orange wire

Red wire

Yellow wire

Green wire

Green/Yellow wire

NOT USED

7-WireOperatorCable

5” or less

21”Typical

27.5”Max

Photo Sensors Height

Close Beam

Open Beam

Open Beam

Close Beam

Reversing EdgePhoto Sensor

Photo Sensor

Sensor mounted just below actuator arm cable.

Gate

Ope

ned

Gate Closed

OutsideProperty

InsideProperty

Single operator connects to PRIMARY connection ONLY on the 115 VAC OR Solar control box circuit board.

1

78

65432

PRIMARY

4302

The 6004 is intended for installation only on swing gates used for vehicles.Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to 6004 Actuator Arm and Control Box Mounting manual, 115 VAC or Solar Control Box Wiring/Owner’s manuals.

THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. Visit www.dkslocator.com to find a professional installing and servicing dealer in your area.

Gate

Clo

sed

Left-Side Right-Side

Securely mount a control box near the actuator arm with appropriate hardware

(not supplied).

Control Box 115 VACor SolarPowerInput

Opening Direction DIP-Switch 1 (SW 1)

Refer to YOUR chosen 115 VAC OR Solar powered control box manuals for complete DIP-switch settings.

DO NOT cycle operator before limit switches and DIP-switches have been adjusted, damage could

occur to gate and operator.

Limit

Slow

Down

Slow Down

Limit

Top LimitRing

BottomLimit Ring

SlowDown

Thru-Bolt

Thru-Bolt

Manually move the gate to the desired open or closed position. Loosen the limit screws and slowly rotate the limit rings until the LIMIT LEDs on the circuit board light up.

Reversing Edge is mounted along ENTIRE end of gate.

Wiring to Circuit Board

PotentialEntrapment

Area

Factory wired jumpers MUST be removed.

Note: Only 1 monitored Device can be connected for each cycling direction. An OPTIONAL Expansion Kit (sold separately) will allow connection for additional devices.Refer to YOUR chosen 115 VAC OR Solar powered control box manuals to wire entrapment protection devices.

Open to the Outside - Refer to 6004 manual

“Open to the Inside” InstallationNote: Refer to 6004 manual for “Open to the Outside” installation.

Opento theInside

The operator MUST OPEN GATE upon initial power up and OPEN command.If the operator closes gate after giving open command, shut off power and reverse this switch setting otherwise operator will NOT function correctly.

ExternalEntrapmentProtection

DevicesEntrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists. The operator will not run without one or more monitored type B1 or B2 entrapment protection devices in EACH entrapment area.

UL 325 August2018 Standard