operator disassembly - doorking...dr i ve ar m l i nking ar m arm assembly install the gate...
TRANSCRIPT
Drive Arm
Linking Arm
Arm AssemblyInstall the gate attachment bracket to gate.
LockpinLockpin
Retaining Ring
SpacingWashers
QUICKSTART “BASIC” GUIDELINES FOR MODEL 6004 - FOR GATES UP TO 8 FEET, 300LBS AND “OPENING TO THE INSIDE”
Copyright 2018 DoorKing, Inc. All rights reserved.
Thru
-Bol
t
Note: The mounting bracket and motor can be flipped for right-side opening direction.
Remove cover and 2 thru-bolts to remove and install the mounting bracket.
Note: Lock and unlock directions will be reversed when motor is in the right-side orientation.
Manual Release
Right-Side Orientation
Left-Side Orientation
DO
OR
KI N
G
Motor
Cover
MountingBracket
Note: Linking arm must be in the center hole of the gate attachment bracket.
Opens to theInside
Position of Operator and Arms
OperatorDisassembly
Installing Mounting Bracket and Gate Attachment Bracket
1234567
1234567
CB
A
90°
Linking Arm
“A” inches “B” inches C max. inchesGate Attachment Bracket
2.50 - 4.25
4.25 - 6.25
6.25 - 8.25
8.25 - 10.25
10.25 - 12.25
12.25 - 14.00
28.75
28.25
28.00
27.25
27.00
26.25
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
D O O R K I N G
D O O R K I N G
D O O R K I N G
Support Bar must be used if the operator is mounted in the middle of the gate and span the entire length of the gate to support the gate pickets. The pickets will bend if not supported.
Top
Middle
Bottom
Left-Side Position Right-Side Position
CoaxialCableAntenna(NotSupplied)
OperatorCable
Pow
er
Loop
s
UnlockLock
Unlock
Lock
Mounting Options
Attach mounting bracket to pilaster or wall with four (4) #10 screws and suitable expansion hardware (Not supplied).
Left-Side“Bottom”Positionshown.
1 5/8”
Brackets MUST beinstalled level!
Weld gate attachment bracket to gate or use two (2) suitable screws (Not supplied).
Brackets MUST be securely attached. Extreme force will be exerted on
brackets during normal gate cycling.
120 S. Glasgow AvenueInglewood, California 90301
U.S.A.
Limit Switch AdjustmentLimit LEDs
Slow Down LEDs
Circuit board power must be ON when adjusting the limit rings, LEDs will light while turning the limit rings.
4302
4302
Arms MUST beinstalled level!
6004-066-G-8-18
Brown wire
Blue wire
Orange wire
Red wire
Yellow wire
Green wire
Green/Yellow wire
NOT USED
7-WireOperatorCable
5” or less
21”Typical
27.5”Max
Photo Sensors Height
Close Beam
Open Beam
Open Beam
Close Beam
Reversing EdgePhoto Sensor
Photo Sensor
Sensor mounted just below actuator arm cable.
Gate
Ope
ned
Gate Closed
OutsideProperty
InsideProperty
Single operator connects to PRIMARY connection ONLY on the 115 VAC OR Solar control box circuit board.
1
78
65432
PRIMARY
4302
The 6004 is intended for installation only on swing gates used for vehicles.Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to 6004 Actuator Arm and Control Box Mounting manual, 115 VAC or Solar Control Box Wiring/Owner’s manuals.
THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. Visit www.dkslocator.com to find a professional installing and servicing dealer in your area.
Gate
Clo
sed
Left-Side Right-Side
Securely mount a control box near the actuator arm with appropriate hardware
(not supplied).
Control Box 115 VACor SolarPowerInput
Opening Direction DIP-Switch 1 (SW 1)
Refer to YOUR chosen 115 VAC OR Solar powered control box manuals for complete DIP-switch settings.
DO NOT cycle operator before limit switches and DIP-switches have been adjusted, damage could
occur to gate and operator.
Limit
Slow
Down
Slow Down
Limit
Top LimitRing
BottomLimit Ring
SlowDown
Thru-Bolt
Thru-Bolt
Manually move the gate to the desired open or closed position. Loosen the limit screws and slowly rotate the limit rings until the LIMIT LEDs on the circuit board light up.
Reversing Edge is mounted along ENTIRE end of gate.
Wiring to Circuit Board
PotentialEntrapment
Area
Factory wired jumpers MUST be removed.
Note: Only 1 monitored Device can be connected for each cycling direction. An OPTIONAL Expansion Kit (sold separately) will allow connection for additional devices.Refer to YOUR chosen 115 VAC OR Solar powered control box manuals to wire entrapment protection devices.
Open to the Outside - Refer to 6004 manual
“Open to the Inside” InstallationNote: Refer to 6004 manual for “Open to the Outside” installation.
Opento theInside
The operator MUST OPEN GATE upon initial power up and OPEN command.If the operator closes gate after giving open command, shut off power and reverse this switch setting otherwise operator will NOT function correctly.
ExternalEntrapmentProtection
DevicesEntrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists. The operator will not run without one or more monitored type B1 or B2 entrapment protection devices in EACH entrapment area.
UL 325 August2018 Standard