Code No. 0816452Rev. 3 (11/11)
INSTALLATION INSTRUCTIONS FOR RETROFIT AND COMPLETE VALVE INSTALLATION
LIMITED WARRANTYUnless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from the date of first purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims will be allowed for labor, transportation or other costs. Damage caused by misuse or improper installation are all excluded from this warranty. This warranty extends only to person or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
Prior to installing the Optima Plus flushometer, install the items listed below as illustrated in the Rough-in Diagram. (New installations only.)• ClosetorUrinalfixture• Drainline• Watersupplyline
Important:• ALLPLUMBINGSHOULDBEINSTALLEDINACCORDANCEWITH
APPLICABLE CODES AND REGULATIONS.• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN
ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.• WHEN INSTALLINGAFLUSHOMETER, IT IS IMPORTANTTHAT
THE FLUSH MODEL MATCHES THE REQUIREMENTS OF THE PLUMBING FIXTURE.
• FLUSHALLWATERLINESPRIORTOMAKINGCONNECTIONS.
The Optima Plus is designed to operate with 15 to 100 PSI (104 to 689 kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED. Consult fixture manufacturer for pressure requirements.Most Low Consumption water closets (1.6 gallon/6 liter) require a minimum flowing pressure of 25 psi (172 kPa).
8100 Series Complete Flushometer Models8100 Series Optima Plus valves are complete flushometer
valves and ideal for new installations.
RESSSeriesRetrofitConversionKitModelsRESS Optima Plus models are used to convert existing Royal,
Regal and Sloan style flushometers to sensor activation.
Optima Plus Water Closet Models can be furnished for the following:1.6 gpf/6.0 Lpf For Low Consumption Bowls2.4 gpf/9.0 Lpf For 9 Liter European Water Closets3.5 gpf/13.2 Lpf For older Water Closets
Optima Plus Urinal Models can be furnished for the following:0.5 gpf/1.9 Lpf For Wash Down Urinals1.0 gpf/3.8 Lpf For Low Consumption Urinals1.5 gpf/5.7 Lpf For older Siphon Jet Urinals3.5 gpf/13.2 Lpf For older Blow Out Urinals
Made in the U.S.A.
PRIOR TO INSTALLATION
TOOLS REQUIRED FOR INSTALLATION• Slottedscrewdrivertoadjustcontrolstop.• SloanA-50Super-Wrench™,SloanA-109PlierWrenchorsmoothjawed
spud wrench for couplings.
• Trimpotadjustmentscrewdriver(supplied)toadjustrange,ifnecessary.• Strapwrench(supplied)toinstallOptimaPlustovalvebody.• 7/64”hexwrench(supplied)tosecureOptimaPluscovertobaseplate.
WiththeexceptionofControlStopInlet,DONOT use pipe sealant or plumbing grease on any valve
component or coupling!
!!! IMPORTANT !!!
This product contains mechanical and/or electrical components that are subject to normal wear. These
components should be checked on a regular basis and replaced as needed to maintain the valve’s performance.
!!! IMPORTANT !!!
Whenassistanceisrequired,pleasecontact Sloan Technical Support at:
1-888-SLOAN-14 (1-888-756-2614) or visit us online at: www.sloanvalve.com
2
VALVE ROUGH-IN
Typical Water Closet InstallationModel 8110/8111Reference for RESS-C Retrofit
When installing the Optima Plus in a handicap stall:Per the ADA Guidelines (section 604.9.4) it is recommended that the grab bars be split or shifted to the wide side of the stall.
2¼”(57mm)MIN.
16½” (419 mm)
C/L OF WASTE
FINISHED WALL
FINISHED FLOOR
2¼”(57mm)MIN.
“Y”
C/L OF WASTE
FINISHED WALL FINISHED FLOOR
C/L OF FIXTURE
1”I.P.S. (25 mm DN)
SUPPLY
4¾” (121 mm)
High Rough-in Water Closet InstallationModels 8113, 8115 & 8116
“X”
Model 8115 & 8116 valves are designed for installations where thewater supply is roughed-in24” -27” (610mm -686mm)above the top of the water closet.For new installations, Sloan strongly recommends the use of our Model 8111 which has a shorter installation height.
Model “X” “Y”
8113 16”(406mm) 21”(533mm)
8115 24”(610mm) 29”(737mm)
8116 27”(686mm) 32”(813mm)
Typical Urinal InstallationModels 8180 & 8186Reference for RESS-U Retrofit
2¼”(57mm)MIN.
16½” (419 mm)
C/L OF FIXTURE
FINISHED FLOOR
FINISHED WALL
4¾” (121 mm)
81801”I.P.S.
(25 mm DN) SUPPLY8186¾”I.P.S.
(20 mm DN) SUPPLY
C/L OF FIXTURE
1”I.P.S. (25 mm DN)
SUPPLY
4¾” (121 mm)
11½” (292 mm)
11½” (292 mm)
The Strap Wrench provided with Optima Plus is a convenience tool and is not to be used to remove or install the Flushometer
Couplings. Use Strap Wrench ONLY to install Optima Plus Locking Ring.
!!! IMPORTANT !!!
Protect the chrome or special finish of Sloan Flushometers — DO NOT USE toothed tools to install or service these valves. UseaSloanA-50Super-Wrench™,SloanA-109PlierWrench
or smooth jawed spud wrench to secure all couplings. Also see “Care and Cleaning” section of this manual.
!!! IMPORTANT !!!
LAWS AND REGULATIONS PROHIBIT THE USE OF HIGHER FLUSHING VOLUMES THAN LISTED ON
FIXTURES OR FLUSHOMETERS.
!!! IMPORTANT !!!
3
A Measure from finished wall to C/L of Fixture Spud. Cut pipe1¼”(32mm)shorterthan this measurement. Chamfer O.D. and I.D. of water supply pipe.
WATER SUPPLY PIPE
FINISHED WALL
1-1/4”(32 mm)
C/L OF FIXTURE
SPUD
SWEAT SOLDER ADAPTER
B Slide Threaded Adapter fully onto pipe.
C Sweat solder the Adapter to pipe.
WiththeexceptionofControlStopInlet,DONOT use pipe sealant or plumbing grease on any valve
component or coupling!
!!! IMPORTANT !!!
BAK-CHEK®
CONTROL STOP
COVER TUBE
IRON PIPE NIPPLE OR COPPER PIPE WITH SWEAT SOLDER ADAPTER
SET SCREW
SUPPLY FLANGE
WATER SUPPLY PIPE
SWEAT SOLDER ADAPTER
COVER TUBE
WALL FLANGE
A Measure from finished wall to first thread of Adapter or threaded supply pipe (dimension “X”).CutCoverTubetothis length.
B Slide Cover Tube over pipe. Slide Wall Flange over Cover Tube until against wall.
Thread Control Stop onto pipe. Tighten with a wrench.
C
TightenSetScrewwitha1/16”hex wrench. DO NOT install Vandal Resistant Stop Cap at this time.
D
1 - FOR COMPLETE VALVE INSTALLATION START HERE. FOR RESS RETROFIT INSTALLATION,STARTATSTEP6.INSTALLOPTIONALSWEATSOLDERADAPTER (ONLY IF YOUR SUPPLY PIPE DOES NOT HAVE A MALE THREAD)
2-INSTALLCOVERTUBE,WALLFLANGEANDCONTROLSTOPTOSUPPLYPIPE
3 - FLUSH OUT SUPPLY LINE
A Open Control Stop.
C Close Control Stop.
B Turn on water supply to flush line of any debris or sediment.
“X”
VACUUM BREAKER
TUBE
SPUD COUPLING
NYLON SLIP GASKET
RUBBER GASKET
SPUD FLANGE
A Slide Spud Coupling, Nylon Slip Gasket, Rubber Gasket and Spud Flange over Vacuum Breaker Tube.
B Insert Tube into Fixture Spud.
C Hand tighten Spud Coupling onto Fixture Spud.
VACUUM BREAKER
TUBE
SPUD COUPLING
NYLON SLIP GASKET
RUBBER GASKET
SPUD FLANGE
MODELS 8110/8111, 8115, 8116
MODEL 8180 MODEL 8186
IfcuttingVacuumBreakerTubetosize,notethatCritical Line (C/L) on Vacuum Breaker must typically
be 6” (152 mm) above fixture. Consult Code for details.
NOTE
4-INSTALLVACUUMBREAKERFLUSHCONNECTION
4
C Align Flushometer Body and securely tighten first the Tailpiece Coupling (1), then the Vacuum Breaker Coupling (2), and finally the Spud Coupling (3). Use a wrench to tighten these couplings in the order shown.
B Align Flushometer directly above the Vacuum Breaker Flush Connection by sliding the Flushometer Body IN or OUT as needed. Tighten Vacuum Breaker Coupling by hand.
A LubricatetailpieceO-ringwithwater.InsertAdjustableTailpieceinto Control Stop. Tighten Tailpiece Coupling by hand.
Maximum adjustment of the Sloan Adjustable Tailpiece is 1/2” (13 mm) IN or OUT from the standard
4-3/4” (121 mm) (centerline of Flushometer to centerline of Control Stop).
Ifroughing-inmeasurementexceeds5-1/4”(133mm),consult factory for longer tailpiece.
NOTE
An extra H-533 Tail O-ring is included in the event leakage occurs if the valve is repositioned during the installation of the new Optima Plus.
USE ONLY AS NEEDED.
NOTE
A Remove Control Stop Cap.
C Remove Outside and Inside Covers and old Inside Parts Kit.
B Turn off water supply at Control Stop. Push Valve Handle to relieve water pressure.
G-44 FRICTION RING
C/L SUPPLY
ADJUSTABLE TAILPIECE
C/L FIXTURE
CONTROL STOPO-RING
TAILPIECE COUPLING
VACUUM BREAKER FLUSH CONNECTION
VACUUM BREAKER COUPLING
FLUSHOMETER BODY
4-3/4” (121 mm)
D Remove old Handle Assembly and Gasket.
E Install Chrome Handle Cap with Gasket to handle opening on Flushometer Body. Tighten Chrome Handle Cap securely.
H-533 TAIL O-RING
A
C
E
B
D RESS SERIES INSTALLATIONS ONLY
1
2
SPUD COUPLING
3
VACUUM BREAKER REPAIR KIT
5 - INSTALL FLUSHOMETER
6-WHENRETROFITTINGANEXISTINGVALVE,STARTHERE.REMOVECOMPONENTSFROM EXISTING FLUSHOMETER (RESS RETROFIT INSTALLATIONS ONLY)
55
O-RING
REGULATOR (MUST BE INSTALLED
PAST O-RING)
FLEX TUBE DIAPHRAGM
The Flush Volume of the Optima Plus is controlled by the Regulator in the Flex Tube Diaphragm Kit. Regulators are identified by color.
OPTIMA PLUS ASSEMBLY
B Insert metal end into hole in base of Optima Plus Assembly. O-ring must be fully inserted into the hole.
A Make sure Flush Volume Regulator is Installed Past O-ring.
O-RING
VALVE BODYFLEX TUBE
DIAPHRAGM
C Push Diaphragm securely against underside of Optima Plus Assembly. Place entire Assembly onto the Valve Body.
To facilitate installation, wet the diaphragm assembly (on top or completely).
A Thread Locking Ring onto Valve Body.
B Use Strap Wrench provided to tightly secure Locking Ring.
If retrofitting the Optima Plus onto a Zurn valve body, a special Locking Ring must be used (identified by a machined groove around the ring).
OrdertheOptimaPluswiththe“Z”variationtoreceivetheunitsuppliedwith this Ring.
A Remove the Tab located over the Override Button to activate the Sensor Module.
B For the first ten (10) minutes of operation, a Visible Red Light flashes in the Sensing Window of the Optima Plus Flushometer when a user is detected.
Sensor Lens must face directly forward. Rotating the Sensor to either side will decrease the Sensor’s ability
to detect a target.
NOTE
7 - OPTIMA PLUS FLUSH VOLUME
8 - ASSEMBLE FLEX TUBE DIAPHRAGM TO OPTIMA PLUS ASSEMBLY
9-TIGHTENLOCKINGRING
10 - REMOVE TAB TO ACTIVATE SENSOR MODULE
LAWS AND REGULATIONS PROHIBIT THE USE OF HIGHER FLUSHING VOLUMES THAN LISTED
ON FIXTURES OR FLUSHOMETERS.
!!! IMPORTANT !!!
The Locking Ring must be installed down past the valve body threads by at least one thread. If difficulty is experienced
installingtheLockingRing,turntheLockingRingbackandforth,eachtimeworkingitfurtherdownthethreads.The
Locking Ring will act as a thread chaser in the event there has been a build-up of matter on the threads of the old valve body.
!!! IMPORTANT !!!
6
B Stand in front of Sensor for ten (10) seconds
C Step away from Sensor andlistenfor“CLICK.”
A Test Sensor with Cover in Place.
The Optima Plus has a factory set sensing range:WaterClosetModels-22”to42”(559mmto1067mm)UrinalModels-15”to30”(381mmto762mm)
The factory setting should be satisfactory for most installations.Ifarangeadjustmentisrequired,refertotheRange Adjustment instructions on this page.
1. A continuous, INVISIBLE light beam is emitted from the Optima Plus Sensor.
2. As the user enters the beam’s effective range, 22 to 42 inches (559 mm to 1067 mm) for closet installations and 15 to 30 inches (381 mm to 762 mm) for urinal installations, the beam is reflected into the Scanner Window to activate the Output Circuit. Once activated, the Output Circuit continues in a “hold”modeforaslongasthe user remains within the effective range of the sensor.
The Optima Plus has a factory set sensing range:WaterClosetModels-22”to42”(559mmto1067mm)UrinalModels-15”to30”(381mmto762mm)
The Factory setting should be satisfactory for most installations.
If the range is too short (i.e., not picking up users) or too long (i.e., picking upoppositewallorstalldoor)therangecanbeadjusted.
Note: Water does not have to be turned off to adjust range.
Refer to Illustration on Next Page.Loosen the two Screws on top of the unit. Remove the Override Button. Remove the Rubber Plug from top of Electronic Sensor Module to uncover the Potentiometer.
RANGE ADJUSTMENT PROCEDUREFor the first ten (10) minutes of operation, a Visible Red Light flashes in the Sensing Window of the Optima Plus Flushometer when a user is detected. This Visible Red Light feature can be reactivated after ten (10) minutes by opening and closing the Battery Compartment Door.
D Install Control Stop Cap onto Control Stop. For RESS retrofit applications, reuse Stop Cap from existing valve. In complete valve installations, a new Stop Cap is provided.For G2 models, follow the instructions packaged with the Free Spinning Vandal Resistant Stop Cap.
B Activate Flushometer by placing hand in front of Optima Plus Sensor Lens for ten (10) seconds (or press override button) and then moving it away.
A Open Control Stop COUNTERCLOCKWISE ½ turn from closed position.
C AdjustControlStopaftereachflushuntiltherateofflowdeliveredproperly cleanses the fixture.
(Continued on next page.)
11 - TEST SENSOR OPERATION
12 - ADJUST CONTROL STOP AND INSTALL VANDAL RESISTANT STOP CAP
OPERATION
RANGE ADJUSTMENT (ADJUST ONLY IF NECESSARY)
3. When the user steps away, the loss of reflected light initiates an electrical “one-time”signalthatactivates the flushing cycle to flush the fixture. The Circuit automatically resets and is ready for the next user.
The flushometer is engineered for quiet operation. Excessivewaterflowcreatesnoise,whiletoolittle water flow may not satisfy the needs of the fixture.
Proper adjustment is made when plumbing fixture is cleansed after each flush without splashing water out from the lip
AND a quiet flushing cycle is achieved.
!!! IMPORTANT !!!
The Control Stop should never be opened to the point where the flow from the valve exceeds the flow capability of the
fixture.Intheeventofavalvefailure,thefixturemustbeableto accommodate a continuous flow from the valve.
!!! IMPORTANT !!!
7
Check the range by stepping toward the unit until the Red Light flashes, indicatingtheSensor’smaximumdetectionlimit.AdjusttheRangePotentiometer Screw located on top of the Sensor Module a few degrees CLOCKWISE to increase the range or a few degrees COUNTERCLOCKWISE todecreasetherange.Repeatthisadjustmentuntilthedesiredrangeisachieved.
Always Determine the Sensing Range with Metal Cover and Lens Window On Top of the Unit.
Whenrangeadjustmentissatisfactory,replacetheRubberPlug.ReinstallOverride Button and tighten the two Screws on top of the unit.
COUNTER- CLOCKWISE CLOCKWISE
Decreases Range
Increases Range
When required, replace batteries with four (4) Alkaline AA-Size Batteries.
Note: Water does not have to be turned off to replace Batteries.
Loosen the two (2) Screws on top of unit. Remove the complete Cover Assembly. Lift the Sensor Module from its Plate. Unplug the Electrical Connector from Battery Compartment Cover. Loosen the Retaining Screw on Battery Compartment Cover and remove Battery Compartment Cover. Install four (4) Alkaline AA-Size Batteries exactly as illustrated.
BATTERY COMPARTMENT
COVER
ELECTRICAL CONNECTOR RECEPTACLE
SENSOR MODULE
RETAINING SCREW
COVER ASSEMBLY
SENSOR MODULE
PLATE
1. Sensor Flashes Continuously Only When User Steps Within Range.A. Unit in Start-Up mode; no problem. This feature is active for the first ten (10)
minutes of operation.2. Valve Does Not Flush; Sensor Not Picking Up User.
A. Range too short; increase the range.3. Valve Does Not Flush; Sensor Picking Up Opposite Wall or
Surface,orOnlyFlushesWhenSomeoneWalksBy.RedLightFlashes Continuously for First 10 Minutes Even with No One in Front of the Sensor.A. Range too long; shorten range.
4. Valve Does Not Flush Even After Adjustment.A.RangeAdjustmentPotentiometersetatfull“max”orfull“min”setting.
ReadjustPotentiometerawayfromfull“max”or“min”setting.B. Batteries completely used up; replace batteries.C. Problem with Electronic Sensor Module; replace Electronic Sensor Module.
5. Unit Flashes 4 Quick Times When User Steps Within Range.A. Batteries low; replace batteries.
6. Valve Does Not Shut Off.A. Bypass orifice in diaphragm is clogged with dirt or debris, or bypass is clogged
byaninvisiblegelatinousfilmdueto“over-treated”water.Removeflextubediaphragm and wash under running water.
Note: Size of Orifice in the Bypass is of utmost importance for the proper metering of water by the valve. DO NOT ENLARGE OR DAMAGE THIS ORIFICE. Replace flex tube diaphragm if cleaning does not correct the problem.
B. Dirt or debris fouling stem or flex tube diaphragm. Remove flex tube diaphragm and wash under running water.
C. O-ring on stem of flex tube diaphragm is damaged or worn. Replace O-ring if necessary.
D. Problem with Electronic Sensor Module; replace Sensor Module.
7. Not Enough Water to Fixture.A. Wrong Flush Volume Regulator installed in Flex Tube Diaphragm Kit. Install the
correct Regulator (see Step 7 of these instructions).B. Wrong Optima Plus model installed; i.e., 1 gpf. urinal installed on 3.5 gal.
closet fixture. Replace with proper Optima Plus model, or refer to the G2 Optima Plus Conversion Guide to convert existing unit to the proper model.
C. Enlarged Bypass in Diaphragm. Replace Flex Tube Diaphragm.D.ControlStopnotadjustedproperly.ReadjustControlStop.E. Inadequate volume or pressure at supply. Increase water pressure or supply
(flow) to valve. Consult factory for assistance.8. Too Much Water to Fixture.
A. Wrong flush volume regulator installed in flex tube diaphragm kit. Install the correct regulator (see Step 7 of these instructions).
B.ControlStopnotadjustedproperly.ReadjustControlStop.C. Wrong Optima Plus model installed; i.e., 3 gpf. model installed on 1.0 or 1.5
gal. urinal fixture. Replace with proper Optima Plus model, or refer to the G2 Optima Plus Conversion Guide to convert existing unit to the proper model.
D. Dirt in diaphragm bypass. Clean under running water or replace flex tube diaphragm.
Note: The EBV-46-A Beam Deflector is no longer required or available for the G2 Optima Plus.
Whenfurtherassistanceisrequired, please contact Sloan Technical Support at:
1-888-SLOAN-14 (1-888-756-2614) or visit us online at: www.sloanvalve.com
RANGE ADJUSTMENT (ADJUST ONLY IF NECESSARY) - CONTINUED
TROUBLESHOOTING
BATTERY REPLACEMENTInstall Battery Compartment Cover and secure with Retaining Screw. Make certain that Battery Compartment Cover is fully compressed against Gasket to provide a seal; Do Not overtighten. Plug the Electrical Connector into the Battery Compartment Cover. Reinstall the Sensor Module onto the Plate. Reinstall the complete Cover Assembly onto the Plate. Tighten the two (2) Screws on top of the unit.
LAWS AND REGULATIONS PROHIBIT THE USE OF HIGHER FLUSHING VOLUMES THAN LISTED ON
FIXTURES OR FLUSHOMETERS.
!!! IMPORTANT !!!
Adjust in small increments only! Range Potentiometer Adjustment Screw rotates only ¾ of a turn;
DO NOT over-rotate.
!!! IMPORTANT !!!
SLOANHEADQUARTERS•10500SEYMOURAVENUE•FRANKLINPARK,IL60131Phone:1-800-9-VALVE-9or1-800-982-5839•Fax:1-800-447-8329or1-847-671-4380•www.sloanvalve.com
Copyright © 2011 SLOAN VALVE COMPANY Code No: 0816452 – Rev. 3 (11/11)
Theinformationcontainedinthisdocumentissubjecttochangewithoutnotice.
Item # Part # Description
Items Included with RESS Retrofit and Complete Optima Plus Valves 1 – Cover/Ring/Sensor Assembly 2A EBV-142-A Cover Assembly (G2 Optima Plus models) 2B EBV-192-A Cover Assembly (Sloan Optima Plus models) 3 EBV-130-A Override Button Assembly (includes screws & hex
wrench) EBV-132-A Screws (2) and Hex Wrench Only 4 EBV-131 Lens Window Cover 5 EBV-168 Locking Ring EBV-172 Locking Ring - for Zurn valves 6 EBV-129-A-C Electronic Module - Water Closet EBV-129-A-U Electronic Module - Urinal 7 EBV-134 Cover Rest Plate 8 EBV-145-A Inside Cover Assembly (includes solenoid) 9 EBV-136-A Solenoid 10A † G2 Optima Plus Flex Tube Diaphragm Assembly 10B † Sloan Optima Plus Flex Tube Diaphragm
Assembly 11 † Flush Volume Regulator 12 EBV-1017-A Handle Cap 13 EBV-91 RangeAdjustmentTool 14 EBV-22 Strap Wrench 15 EBV-137 7/64”HexWrench
Items Included with Complete Optima Plus Valves Only 16 H-633-AA 1”(25mm)SweatSolderKit H-636-AA ¾”(19mm)SweatSolderKit 17 H-700-A 1”(25mm)Bak-Chek® Control Stop H-700-A ¾”(19mm)Bak-Chek® Control Stop 18 H-1010-A Vandal Resistant Stop Cap 19 EBV-36-A Valve Body 20A V-600-AA 1½”(38mm)VacuumBreaker 20B V-600-AA 1¼”(32mm)VacuumBreaker(Model8180) 20C V-600-AA ¾”(19mm)VacuumBreaker(Model8186) 21A F-5-AT 1½”SpudCouplingAssembly
(Models 8110, 8111, 8115 & 8116) 21B F-5-AU 1¼”SpudCouplingAssembly(Model8180) 21C F-5-AW ¾”SpudCouplingAssembly(Model8186)
† Part No. various depending on valve model, please contact your local Sloan Representative or Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614)
DO NOT use abrasive or chemical cleaners to clean flushometers as they may dull the luster and attack the chrome or special decorative finishes. Use ONLY soap and water, then wipe dry with clean cloth or towel.While cleaning the bathroom tile, the Flushometer should be protected from any splattering of cleaner. Acids and cleaning fluids can discolor or remove chrome plating.
Manufactured in the U.S.A. by Sloan Valve Company under one or more of the following patents: U.S. Patents: D598,975; 7,124,997. Other Patents Pending. BAK-CHEK®, PARA-FLO®, PERMEX®, TURBO-FLO®.
171816
20A
2A
20B 20C
21A 21B 21C
3
4
51
7
8
9
10A10B
19
14
13
11
15
6
12
Optima Plus Valve Models Feature Sloan’s Exclusive Flex Tube Diaphragm for the ultimate in valve performance, reliability and chloramines resistance.
PARTS LIST