ORRFIRE® Product CatalogueSprinkler & Hydrant Pipe
Orrcon Steel is a leading Australian distributor and manufacturer of Steel, Tube and Pipe.
We have distribution centres in five Australian states and a number of branches, stockists and resellers nation-wide.
Orrcon Steel adheres to principles of quality, innovation, flexibility and dedication. These principles are achieved by going the extra mile in everything we do and working in partnership with our customers and suppliers.
At Orrcon Steel – we’ll see it through.
ORRFIRE® Pipe is a leading product specifically designed
for pressure reticulation in commercial and industrial fire
protection applications.
All Orrcon Steel ORRFIRE® products offered to the fire
protection market have ActivFire® Scheme* approval and are
listed under the register of fire protection equipment.
Orrcon Steel ORRFIRE® products cover a diverse range of
wall thicknesses and diameters from extra light through
to medium wall and 25NB through to 300NB. A variety of
surface finishes are available for use in the fire protection
industry, from sprinkler systems through to hydrants.
*ActivFire® Scheme is a registered trademark of CSIRO - MSE
2 | ORRFIRE® Product Catalogue
we’ll see it through
ORRFIRE® PIPEORRFIRE® Pipe is available as sprinkler and hydrant pipe. All sprinkler and hydrant pipe products are designed to comply with AS 4118.2.1 and AS 2419.ORRFIRE® finishes include:• SMARTCOTE® (painted in Red Gum finish)• ALLGAL® inline zinc coating• Hot Dipped Galvanised.
SMARTCOTE® SPRInklER PIPESMARTCOTE® painted sprinkler pipe is a leading Australian made product designed for pressure reticulation in commercial and industrial fire protection applications. SMARTCOTE® is a water based acrylic primer applied to a nominal 20 micron thickness. A Red Gum* coloured primer is applied to the external surface of the steel using Orrcon Steel’s SMARTCOTE® technology. ORRFIRE® SMARTCOTE® is designed for use in “closed systems” only, such as fire sprinkler assemblies. SMARTCOTE® painted firepipe is easy to weld and as a keyed primer can be readily painted over if necessary. SMARTCOTE® painted pipe is approved by the ActivFire® Scheme for use in fire protection systems and is covered by afp 1510, 1511, 1641 and 2481 certificates of conformity.
SMARTCOTE® – VOC Specification SMARTCOTE® painted pipe is a finished product that has zero Volatile Organic Compounds (VOC’s) with respect to the ‘Green Star’ building rating as it arrives onsite pre-primed. SMARTCOTE® complies with Australian Standards on paint formulation and as such does not contain any of the following:• Glycol Ethers• Prohibited, restricted or carcinogenic substances• Heavy metals• Ozone depleting substances
*The manufactured colour of the SMARTCOTE® pipe is Red Gum. The colour of the SMARTCOTE® pipe shown in this brochure can vary due to the post painting application of Fire Red carried out on specified projects.
AllGAl® SPRInklER PIPE
ORRFIRE® ALLGAL® is an Australian made sprinkler pipe product that is manufactured using an inline zinc-coated steel feed strip.
ALLGAL® is easy to weld and can be either ‘touched up’ in weld areas with zinc paint and installed as supplied or painted if necessary.
It is approved by the ActivFire® Scheme for use in fire protection systems and is covered by afp 1508, 1509, 1528 and 1640 certificates of conformity.
HOT DIPPED GAlVAnISED SPRInklER & HYDRAnT PIPE
ORRFIRE® Hot Dipped Galvanised Pipe is an Australian made product specifically manufactured for the Fire and Industrial Plumbing Industries.
It undergoes a hot dipped galvanising process prior to being made available for use in the fire protection (sprinkler and hydrant) and other associated reticulation industries.
ORRFIRE® Hot Dipped Galvanised Pipe is zinc galvanised on both the internal and external surfaces with a minimum coating weight of 300g/m2 applied in accordance with AS 4792.
The latest galvanising technology is applied to the product and it is designed for use in ‘open reticulation systems’ where oxygenated water is transported.
ORRFIRE® Hot Dipped Galvanised Pipe is approved by the ActivFire® Scheme for use in fire protection and hydrant systems and is covered by afp 1529 and 1530 certificates of conformity.
Note: The availability of Hot Dipped Galvanised Sprinkler & Hydrant
Pipe is subject to availability. Please contact your local Orrcon Steel
Representative for more information.
3we’ll see it through
EquIPMEnT lISTInG SCHEME
All Orrcon Steel products offered to the fire protection market have ActivFire® Scheme approval and are listed under the register of fire protection equipment. ActivFire® Scheme is your assurance that Orrcon Steel products have met the stringent requirements of CSIRO’s accreditation process. All Orrcon Steel ActivFire® certified products are deemed to comply with the following standards:
• AS 2419.1 - Fire Hydrant Installations
• AS 4118.2.1 - Fire Sprinkler Systems - Piping - General
• AS 1074 - Steel tubes and tubulars for ordinary services
The CSIRO ActivFire® Scheme for certification and listing of ActivFire® protection equipment includes the following objectives:1
• To verify the conformity (compliance) of equipment through physical testing and appraisal to relevant and endorsed standards and specifications (reference criteria).
• To verify and recognise approvals and certifications by other national and International bodies.
• To provide an effective and transparent mechanism for appraisal, testing, certification and listing of emerging and new technologies in the field of active fire protection equipment and systems.
• To provide reference documentation and information which supports the various building regulation and authority requirements for “evidence of suitability” for equipment used in building construction.
• To maintain a continuing process that provides means by which the conformity of changes to products can be submitted and verified.
• To maintain a Register of Fire Protection Equipment to publicly list and promote products which meet established reference criteria for listing.
Procedures and mechanisms for monitoring compliance and performance can vary. Listed products are identified in the Register of Fire Protection Equipment. This resource exists primarily as an on-line database accessed through the website www.activfire.gov.au. Information is also provided online such as product listing data sheets published for many of ActivFire’s® registered listings and technical specifications.
1 Reference: CSIRO ActivFire® protection – product certification viewed 23/07/12, http://activfire.gov.au.
4 | ORRFIRE® Product Catalogue
Product Designation ActivFire® Scheme Approval Listing Number
ORRFIRE® SMARTCOTE® Painted Red Gum Extra Light pipe afp 1641
ORRFIRE® SMARTCOTE® Painted Red Gum Light pipe afp 1510
ORRFIRE® SMARTCOTE® Painted Red Gum Medium pipe afp 1511
ORRFIRE® SMARTCOTE® Painted Red Gum Sprinkler & Hydrant pipe - Extra Light and Light afp 2481
ORRFIRE® ALLGAL® Zinc Coated Extra Light pipe afp 1640
ORRFIRE® ALLGAL® Zinc Coated Extra Light pipe - 100NB and above afp 1528
ORRFIRE® ALLGAL® Zinc Coated Light pipe afp 1508
ORRFIRE® ALLGAL® Zinc Coated Medium pipe afp 1509
ORRFIRE® Hot Dipped Galvanised Sprinkler & Hydrant pipe - Extra Light and Light afp 1529
ORRFIRE® Hot Dipped Galvanised Sprinkler & Hydrant pipe - Medium afp 1530
Current ActivFire® Scheme approvals are listed below. Copies of ActivFire® Scheme certificates are available from www.orrconsteel.com.au/downloads
5we’ll see it through
MAnuFACTuRInG
Leak tightness is in accordance with AS1074 using inline eddy current testing. This is equivalent to a hydrostatic pressure of 500kPa.
The internal weld bead of the pipe is not removed, however the external weld bead is scalped flush with the outer surface of the pipe prior to painting or zinc repair.
The standard end finish is plain end. A range of optional end treatments are available subject to enquiry, including roll grooved ends and threaded one end (refer to page 8 for specifications).
The standard stock length available is 6.5 metres. Non standard lengths up to 12 metres are available ex rollings subject to enquiry.
MAnuFACTuRInG TOlERAnCES
Tolerances applicable to ORRFIRE® Sprinkler Pipe are:
localised Wall Thickness: Not less than 10% of nominal wall thickness.
Linear Mass: - 4.0% to +10% for any length.
Straightness: Deviation from straight line = stock length (6.5m) / 250.
Length: Standard stock length tolerance is +50mm, - 0mm, on nominal length supplied. Special cut lengths + 6mm to 0mm tolerance is subject to enquiry.
PIPE MARkInG
Each straight length of pipe is permanently marked once per length with information on the manufacturer, size, wall thickness and grade. The minimum height of the lettering is 15mm.
SMARTCOTE® SPRInklER PIPE - APPlICATIOnS AnD RECOMMEnDED uSE
Applications:
• Fire sprinkler system applications for all “closed” oxygenated systems.
• Hydraulic installations and compressed air services.
• Heating, ventilation and air conditioning systems with “closed” pipe work systems.
Recommended Use:
• Extra light and light wall SMARTCOTE® is suitable for use with all reputable roll grooved coupling systems.
• Medium wall SMARTCOTE® can be used with threaded or roll grooved jointing systems.
AllGAl® SPRInklER PIPE - APPlICATIOnS AnD RECOMMEnDED uSE
Applications:
• Fire sprinkler applications for all “closed” non-oxygenated systems.
• Hydraulic installations and compressed air services.
• Heating, ventilation and air conditioning with “closed” pipe work systems.
Recommended Use:
• Extra light and light wall ALLGAL® pipe is suitable for use with all reputable roll grooved coupling systems.
• Medium wall ALLGAL® pipe can be used with threaded or roll grooved jointing systems.
6 | ORRFIRE® Product Catalogue
ORRFIRE® HOT DIPPED GAlVAnISED PIPE - APPlICATIOnS AnD RECOMMEnDED uSE
Applications:
• Fire system applications for all “open” oxygenated systems.
• Industrial plumbing and mechanical services.
• Hydraulic installations and compressed air services.
• Mining air / water services.
• Building services and heating, Ventilation and Air Conditioning (H.V.A.C).
• Process plant pipelines.
Recommended Use:
• Substitution of light wall spiral welded, plastic ductile iron and copper pipes in reticulation applications.
HOT DIPPED GAlVAnISED PIPE - MECHAnICAl JOInTInG SYSTEMS
• All pipe wall thicknesses listed in the ORRFIRE® pipe range table are suitable for use with all approved roll grooved or shouldered couplings.
• Where threaded systems are used, only medium and heavy wall pipe is acceptable.
•Hot Dipped Galvanised pipe is approved for use in underground applications when used with ActivFire® Scheme UL or FM approved coupling systems. Hot Dipped Galvanised Pipe is approved for underground applications in accordance with AS 4118.2.1 and AS 2419.1 provided that suitable external pipe corrosion protection is provided.
HOT DIPPED GAlVAnISED PIPE -CORROSIOn PROTECTIOn
Buried Service
Orrcon Steel ORRFIRE® Hot Dipped Galvanised Pipe, when buried underground, must be further protected from external corrosion by:
• Coating with a high density polyethylene plastic jacket or wrapped with a polyethylene tape of minimum thickness 1.0mm applied in accordance with Australian Standard AS1518; Or
• Wrapping in a reputable proprietary petrolatum based tape (eg. Denso) with a minimum of 1.3mm thickness which is over-wrapped with a self-adhesive polyethylene tape with minimum thickness of 225 microns, applied as per manufacturers guidelines.
Mechanical fittings and couplings must also be similarly prepared when installed in buried applications.
Coating Repairs
Damaged coating must be repaired to ensure the integrity of internal and external corrosion resistance. The damaged area should be cleaned with a wire brush and have a quality zinc rich paint (e.g ALLGAL® paint) applied to a minimum thickness in accordance with the paint manufacturers recommendations.
When ORRFIRE® Hot Dipped Galvanised Pipe is roll grooved after galvanising, any flaked area of the internal galvanising should be repaired by this method. Refer to Australian Standard AS1650 Appendix F -1989 Hot Dipped Galvanised Coatings on Ferrous Articles for further details.
7we’ll see it through
ORRFIRE® PIPE SPECIFICATIOnS
DIAMETER TOlERAnCE – ORRFIRE® PIPEDiameter Range (mm)
Nominal Bore Diameter (NB) 20 25 32 40 50 65 80 100 125 150 - 200 250 300
Outside Diameter (OD) 26.9 33.7 42.4 48.3 60.3 76.1 88.9 114.3 139.7 165.1 168.3 219.1 273.1 323.9
Minimum OD 26.63 33.36 41.98 47.82 59.70 75.34 88.01 113.16 138.30 163.45 166.62 216.91 270.37 320.66Maximum OD 27.17 34.04 42.82 48.78 60.90 76.86 89.79 115.44 141.10 166.75 169.98 221.29 275.83 327.14
NOTE: • Outside diameter is fixed for all wall thicknesses.
MECHAnICAl PROPERTIES – ORRFIRE® PIPE
Pipe Dimensions Minimum Yield Strength
Minimum Tensile Strength
Minimum Elongation as a proportion of
gauge length
light Wall Pipe20 TO 150 nB
(3/4 TO 6 INCH)350 MPa 430 MPa 20%
Medium Wall Pipe20 TO 150 nB
(3/4 TO 6 INCH)250 MPa 350 MPa 22%
Schedule200 TO 300 nB (8 TO 12 INCH)
350 MPa 430 MPa 20%
THREADInG SPECIFICATIOnS - ORRFIRE® PIPE
End Treatment Min Diameter (mm) Max Diameter (mm) Min Thickness (mm) Max Thickness (mm)
Threading 25NB 50NB 3.2 4.5
ROll GROOVInG SPECIFICATIOnS - ORRFIRE® PIPE
End Treatment Diameter (mm) Min Thickness* (mm) Max Thickness (mm)
Roll Grooving
50NB 2.3 3.6
65NB 2.3 3.6
80NB 2.6 4.0
100NB 2.5 4.5
125NB 3.0
150NB 3.0
200NB 4.8
250NB 4.8 NOTE: • * Contact your Orrcon Steel Representative for minimum thicknesses outside the listed range.
• Contact your Orrcon Steel Representative for maximum thicknesses which are not listed for the specified diameter pipe.
8 | ORRFIRE® Product Catalogue
ORRFIRE® PIPE RAnGE
Section: ORRFIRE® Pipe - Sprinkler and Hydrant PipeStandard: AS 4118.2.1 / AS 2419.1 / ActivFire® SchemeSurface Finish: SMARTCOTE® / ALLGAL® /Hot Dipped Galvanised*
OD(mm)
nB(mm)
Nominal Thickness
(mm)
DesignationSurface Finish Nominal
Linear Mass (Kg/m)
Nominal Metres /
Tonne(m/t)
Lengths / Pack
Lengths / MiniPakSMARTCOTE® ALLGAL®
6500mm Lengths Standard26.7 20 2.0 XLight ü ü 1.23 814 127 6126.7 20 2.3 Light ü ü 1.40 717 127 6126.7 20 2.6 Medium ü ü 1.56 642 127 6133.4 25 2.0 XLight ü ü 1.56 639 91 3733.4 25 2.6 Light ü ü 1.99 501 91 3733.4 25 3.2 Medium ü ü 2.41 415 91 3742.2 32 2.0 XLight ü ü 1.99 501 61 3742.2 32 2.6 Light ü ü 2.55 392 61 3742.2 32 3.2 Medium ü ü 3.09 323 61 3748.3 40 2.3 XLight ü ü 2.61 383 61 3748.3 40 2.9 Light ü ü 3.25 308 61 3748.3 40 3.2 Medium ü ü 3.56 280 61 3760.3 50 2.3 XLight ü ü 3.29 304 37 1960.3 50 2.9 Light ü ü 4.11 244 37 1960.3 50 3.6 Medium ü ü 5.03 199 37 1976.1 65 2.3 XLight ü ü 4.19 239 37 1976.1 65 3.2 Light ü ü 5.75 174 37 1976.1 65 3.6 Medium ü ü 6.44 155 37 1988.9 80 2.6 XLight ü ü 5.53 181 - -88.9 80 3.2 Light ü ü 6.76 148 - -88.9 80 4.0 Medium ü ü 8.38 119 - -
114.3 100 2.5 - ü ü 6.89 145 - -114.3 100 3.2 XLight ü ü 8.76 114 - -114.3 100 3.6 Light ü ü 9.83 102 - -114.3 100 4.5 Medium ü ü 12.20 82 - -139.7 125 3.0 XLight ü ü 10.11 99 - -139.7 125 3.5 Light ü ü 11.08 85 - -139.7 125 5.0 Medium ü ü 16.60 60 - -165.1 150 3.0 XLight ü ü 11.99 83 - -165.1 150 3.5 Light ü ü 13.90 72 - -165.1 150 5.0 Medium ü ü 19.70 51 - -
Refer Notes Page 10
Table Continues Over Page
9we’ll see it through
ORRFIRE® PIPE RAnGE COnT...
Section: ORRFIRE® Pipe - Sprinkler and Hydrant PipeStandard: AS 4118.2.1 / AS 2419.1 / ActivFire® SchemeSurface Finish: SMARTCOTE® / ALLGAL® /Hot Dipped Galvanised*
OD(mm)
nB(mm)
Nominal Thickness
(mm)
DesignationSurface Finish Nominal
Linear Mass (Kg/m)
Nominal Metres /
Tonne(m/t)
Lengths / Pack
Lengths / MiniPakSMARTCOTE® ALLGAL®
165.1 150 5.4 Heavy ü ü 21.30 47 - -12000mm Lengths Standard
168.3 - 4.8 - 19.35 52 - -168.3 - 6.4 - 25.55 39 - -219.1 200 4.8 - 25.37 39 - -219.1 200 6.4 - 33.57 30 - -273.1 250 4.8 - 31.76 31 - -273.1 250 6.4 - 42.09 24 - -323.9 300 4.8 - 37.77 26 - -355.6 350 4.8 - 41.53 24 - -
NOTES: • Recommended maximum test pressure is 5000 kPa / 725 Psi.• The pipe must be supported to avoid all external loads and free to accommodate thermal expansion.• Refer to page 8 for the mechanical properties of ORRFIRE® Pipe.• These tables are applicable for services where pipe contents temperature does not exceed 250 C̊.• Pipe 20NB up to 150NB is painted in Red Gum acrylic primer.• Pipe 200NB and above is painted in black acrylic primer.• Hot Dipped Galvanised pipe is available subject to enquiry.• Non standard sizes, surface finishes and lengths available, subject to enquiry. Minimum order quantities (MOQ’s) apply.
10 | ORRFIRE® Product Catalogue
PRESSuRE DROP & FlOW RATES
The development of lighter wall, higher grade steel pipe for use with mechanical jointing / coupling has offered reduced costs for the industry in both material and labour costs. A further extension of this development is the opportunity to vary pipe design sizes and the type of pipe product used in a project by incorporating the reduced pressure-drop offered by light wall steel pipes.
The tables on the following pages are intended to assist pipe fabrication designers in optimising the use of mechanically jointed light wall steel pipes in either SMARTCOTE®, ALLGAL® or Hot Dipped Galvanised Pipes.
11we’ll see it through
4 | Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 | 5
00
5
10
15
25
20
30
40 60 120 160
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
20 N OMIN A L P IP E S IZE D I ME N S IO N S
20 N OM IN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 26.90 26.90 19.01 26.75 Norm Thick (mm) = 2.60 2.00 1.02 1.55 Norm Mean I.D. (mm) = 21.70 22.90 16.97 23.65 Surface roughness K = 4.50 4.50 1.50 1.50
00
5
10
15
20
50 100 200150 250
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
2 5 N O MI N A L P IP E S IZ E D I M E N S I O N S
2 5 N O MI N A L S IZ E P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 33.70 33.70 25.35 33.55 Norm Thick (mm) = 3.20 2.00 1.22 1.90 Norm Mean I.D. (mm) = 27.30 29.40 22.91 29.75 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
32 N O MIN A L P IP E S IZE D IME N S IO N S
32 N O MIN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 42.40 42.40 31.70 42.25 Norm Thick (mm) = 3.20 2.00 1.22 2.40 Norm Mean I.D. (mm) = 36.00 38.20 29.26 37.45 Surface roughness K = 4.50 4.50 1.50 1.50
00
4
8
12
16
100 200 400300 500
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min0
0
4
2
8
6
10
12
14
100 200 400300 600500 700PR
ESSU
RE
DR
OP
kPa/
mFLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
40 N OMIN A L P I P E S IZE D IME N S ION S
40 N OMIN A L S I ZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 48.30 48.30 38.50 48.25 Norm Thick (mm) = 3.20 2.30 1.22 2.75 Norm Mean I.D. (mm) = 41.90 43.70 35.61 42.75 Surface roughness K = 4.50 4.50 1.50 1.50
PRESSuRE DROP & FlOW RATES
4 | Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 | 5
00
5
10
15
25
20
30
40 60 120 160
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
20 N OMIN A L P IP E S IZE D I ME N S IO N S
20 N OM IN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 26.90 26.90 19.01 26.75 Norm Thick (mm) = 2.60 2.00 1.02 1.55 Norm Mean I.D. (mm) = 21.70 22.90 16.97 23.65 Surface roughness K = 4.50 4.50 1.50 1.50
00
5
10
15
20
50 100 200150 250
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
2 5 N O MI N A L P IP E S IZ E D I M E N S I O N S
2 5 N O MI N A L S IZ E P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 33.70 33.70 25.35 33.55 Norm Thick (mm) = 3.20 2.00 1.22 1.90 Norm Mean I.D. (mm) = 27.30 29.40 22.91 29.75 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
32 N O MIN A L P IP E S IZE D IME N S IO N S
32 N O MIN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 42.40 42.40 31.70 42.25 Norm Thick (mm) = 3.20 2.00 1.22 2.40 Norm Mean I.D. (mm) = 36.00 38.20 29.26 37.45 Surface roughness K = 4.50 4.50 1.50 1.50
00
4
8
12
16
100 200 400300 500
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min0
0
4
2
8
6
10
12
14
100 200 400300 600500 700
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
40 N OMIN A L P I P E S IZE D IME N S ION S
40 N OMIN A L S I ZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 48.30 48.30 38.50 48.25 Norm Thick (mm) = 3.20 2.30 1.22 2.75 Norm Mean I.D. (mm) = 41.90 43.70 35.61 42.75 Surface roughness K = 4.50 4.50 1.50 1.50
20 NOMiNal BOre PiPe Size
20 NOMiNal BOre PiPe Size DiMeNSiONS
4 | Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 | 5
00
5
10
15
25
20
30
40 60 120 160
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
20 N OMIN A L P IP E S IZE D I ME N S IO N S
20 N OM IN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 26.90 26.90 19.01 26.75 Norm Thick (mm) = 2.60 2.00 1.02 1.55 Norm Mean I.D. (mm) = 21.70 22.90 16.97 23.65 Surface roughness K = 4.50 4.50 1.50 1.50
00
5
10
15
20
50 100 200150 250
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
2 5 N O MI N A L P IP E S I Z E D I M E N S I O N S
2 5 N O M I N A L S IZ E P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 33.70 33.70 25.35 33.55 Norm Thick (mm) = 3.20 2.00 1.22 1.90 Norm Mean I.D. (mm) = 27.30 29.40 22.91 29.75 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
32 N O MIN A L P IP E S IZE D IME N S I O N S
32 N O MIN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 42.40 42.40 31.70 42.25 Norm Thick (mm) = 3.20 2.00 1.22 2.40 Norm Mean I.D. (mm) = 36.00 38.20 29.26 37.45 Surface roughness K = 4.50 4.50 1.50 1.50
00
4
8
12
16
100 200 400300 500
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min0
0
4
2
8
6
10
12
14
100 200 400300 600500 700
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
40 N OMIN A L P I P E S IZE D IME N S ION S
40 N OMIN A L S I ZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 48.30 48.30 38.50 48.25 Norm Thick (mm) = 3.20 2.30 1.22 2.75 Norm Mean I.D. (mm) = 41.90 43.70 35.61 42.75 Surface roughness K = 4.50 4.50 1.50 1.50
25 NOMiNal BOre PiPe Size
25 NOMiNal BOre PiPe Size DiMeNSiONS
12 | ORRFIRE® Product Catalogue
6 | Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 | 7
00
4
2
8
6
10
100 200 400300 600500 700 800 900 1000
PRES
SUR
E D
RO
P kP
a/m
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
5 0 N OMI N A L P IP E S IZE D I ME N S I O N S
50 N O MIN A L S IZE P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 60.30 60.30 50.74 60.35 Norm Thick (mm) = 3.60 2.30 1.22 3.35 Norm Mean I.D. (mm) = 53.10 55.70 48.30 53.65 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
65 N OMIN A L P IP E S IZE D IME N S I O N S
65 N OMIN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 76.10 76.10 63.43 75.35 Norm Thick (mm) = 3.60 2.30 1.22 4.20 Norm Mean I.D. (mm) = 68.90 71.50 60.99 66.95 Surface roughness K = 4.50 4.50 1.50 1.50
00
2
1
3
5
7
4
6
8
200 400 800 1000 1200 1400 1600600 1800
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
00
2
1
4
3
5
6
7
200 400 800600 12001000 1400 1600 1800 2000 2200 2400
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
8 0 N OM I N A L P I P E S I Z E D I M E N S I O N S
8 0 N OM I N A L S I Z E P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 88.90 88.90 76.11 88.90 Norm Thick (mm) = 4.00 2.60 1.53 4.95 Norm Mean I.D. (mm) = 80.90 83.70 72.85 79.00 Surface roughness K = 4.50 4.50 1.60 1.50
00
2
1
4
3
5
500 1000 20001500 30002500
PRES
SUR
E D
RO
P kP
a/m
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
9 0 N O M I N A L P I P E S IZ E D I ME N S I O N S
9 0 N O M I N A L S I ZE P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 101.60 101.60 88.80 101.50 Norm Thick (mm) = 4.00 2.60 1.63 5.55 Norm Mean I.D. (mm) = 93.60 96.40 85.54 90.40 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
4 | Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 | 5
00
5
10
15
25
20
30
40 60 120 160
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
20 N OMIN A L P IP E S IZE D I ME N S IO N S
20 N OM IN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 26.90 26.90 19.01 26.75 Norm Thick (mm) = 2.60 2.00 1.02 1.55 Norm Mean I.D. (mm) = 21.70 22.90 16.97 23.65 Surface roughness K = 4.50 4.50 1.50 1.50
00
5
10
15
20
50 100 200150 250
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
2 5 N O MI N A L P IP E S IZ E D I M E N S I O N S
2 5 N O MI N A L S IZ E P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 33.70 33.70 25.35 33.55 Norm Thick (mm) = 3.20 2.00 1.22 1.90 Norm Mean I.D. (mm) = 27.30 29.40 22.91 29.75 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
32 N O MIN A L P IP E S IZE D IME N S IO N S
32 N O MIN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 42.40 42.40 31.70 42.25 Norm Thick (mm) = 3.20 2.00 1.22 2.40 Norm Mean I.D. (mm) = 36.00 38.20 29.26 37.45 Surface roughness K = 4.50 4.50 1.50 1.50
00
4
8
12
16
100 200 400300 500
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min0
0
4
2
8
6
10
12
14
100 200 400300 600500 700
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
40 N OMIN A L P I P E S IZE D IME N S ION S
40 N OMIN A L S I ZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 48.30 48.30 38.50 48.25 Norm Thick (mm) = 3.20 2.30 1.22 2.75 Norm Mean I.D. (mm) = 41.90 43.70 35.61 42.75 Surface roughness K = 4.50 4.50 1.50 1.50
PRESSuRE DROP & FlOW RATES
40 NOMiNal BOre PiPe Size
50 NOMiNal BOre PiPe Size
65 NOMiNal BOre PiPe Size
40 NOMiNal BOre PiPe Size DiMeNSiONS
50 NOMiNal BOre PiPe Size DiMeNSiONS
65 NOMiNal BOre PiPe Size DiMeNSiONS
4 | Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 | 5
00
5
10
15
25
20
30
40 60 120 160
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
20 N OMIN A L P IP E S IZE D I M E N S IO N S
20 N OM IN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 26.90 26.90 19.01 26.75 Norm Thick (mm) = 2.60 2.00 1.02 1.55 Norm Mean I.D. (mm) = 21.70 22.90 16.97 23.65 Surface roughness K = 4.50 4.50 1.50 1.50
00
5
10
15
20
50 100 200150 250
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
2 5 N O MI N A L P IP E S IZ E D I M E N S I O N S
2 5 N O MI N A L S IZ E P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 33.70 33.70 25.35 33.55 Norm Thick (mm) = 3.20 2.00 1.22 1.90 Norm Mean I.D. (mm) = 27.30 29.40 22.91 29.75 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
32 N O MIN A L P IP E S IZE D IME N S I O N S
32 N O MIN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 42.40 42.40 31.70 42.25 Norm Thick (mm) = 3.20 2.00 1.22 2.40 Norm Mean I.D. (mm) = 36.00 38.20 29.26 37.45 Surface roughness K = 4.50 4.50 1.50 1.50
00
4
8
12
16
100 200 400300 500
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min0
0
4
2
8
6
10
12
14
100 200 400300 600500 700
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
40 N OMIN A L P I P E S IZE D IME N S ION S
40 N OMIN A L S I ZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 48.30 48.30 38.50 48.25 Norm Thick (mm) = 3.20 2.30 1.22 2.75 Norm Mean I.D. (mm) = 41.90 43.70 35.61 42.75 Surface roughness K = 4.50 4.50 1.50 1.50
32 NOMiNal BOre PiPe Size DiMeNSiONS
32 NOMiNal BOre PiPe Size
13we’ll see it through
8 | Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 | 9
00
2
1
4
3
5
500 1000 20001500 3000 3500 40002500
PRES
SUR
E D
RO
P kP
a/m
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
1 00 N O MI N A L P IP E S IZ E D IM E N S ION S
1 0 0 N O MIN A L S IZ E P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 114.30 114.30 101.48 114.30 Norm Thick (mm) = 4.50 2.50 1.63 6.30 Norm Mean I.D. (mm) = 105.30 109.30 95.22 101.70 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
00
1
0.5
2
1.5
2.5
3
3.5
1000 2000 40003000 60005000 7000 8000 9000
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
1 5 0 N O M IN A L P I P E S I ZE D I M E N S I O N S
1 5 0 N O M IN A L S I Z E P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 165.10 165.10 152.25 160.25 Norm Thick (mm) = 5.00 3.00 2.03 8.80 Norm Mean I.D. (mm) = 155.10 159.10 148.19 142.65 Surface roughness K = 4.50 4.50 1.50 1.50
00
2
2.5
0.5
1
1.5
4
3
3.5
4.5
500 1000 20001500 30002500
PRES
SUR
E D
RO
P kP
a/m
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
12 5 N OM IN A L P IP E S IZE D IM E N S I O N S
1 25 N O MI N A L S I ZE P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 139.70 139.70 126.88 140.20 Norm Thick (mm) = 5.00 3.00 1.63 7.65 Norm Mean I.D. (mm) = 129.70 133.70 123.62 124.90 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min0
0
1
0.5
2
1.5
2.5
3000 6000 9000 12000 15000PR
ESSU
RE
DR
OP
kPa/
m
ASTM A 53 SCHEDULE 40AS 1432 COPPER (Grade B)
200 N OMI N A L P IP E S IZE D IME N S I ON S
200 N OMI N A L S IZE P IP E
ORRFIRE® LIGHTAS 1477 CPVC (Class 12)
ASTM A 53 ORRFIRE® AS1432 Copper AS1477 CPVC Sch 40 Light (Grade B) (Class 12) Mean O.D. (mm) = 219.10 219.10 203.00 225.30 Norm Thick (mm) = 7.11 4.80 2.03 12.30 Norm Mean I.D. (mm) = 204.88 209.50 198.94 200.70 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
8 | Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 | 9
00
2
1
4
3
5
500 1000 20001500 3000 3500 40002500
PRES
SUR
E D
RO
P kP
a/m
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
1 00 N O MI N A L P IP E S IZ E D IM E N S ION S
1 0 0 N O MIN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 114.30 114.30 101.48 114.30 Norm Thick (mm) = 4.50 2.50 1.63 6.30 Norm Mean I.D. (mm) = 105.30 109.30 95.22 101.70 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
00
1
0.5
2
1.5
2.5
3
3.5
1000 2000 40003000 60005000 7000 8000 9000
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
1 5 0 N O M IN A L P I P E S I ZE D I M E N S I O N S
1 5 0 N O M IN A L S I Z E P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 165.10 165.10 152.25 160.25 Norm Thick (mm) = 5.00 3.00 2.03 8.80 Norm Mean I.D. (mm) = 155.10 159.10 148.19 142.65 Surface roughness K = 4.50 4.50 1.50 1.50
00
2
2.5
0.5
1
1.5
4
3
3.5
4.5
500 1000 20001500 30002500
PRES
SUR
E D
RO
P kP
a/m
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
12 5 N OM I N A L P I P E S I Z E D IM E N S I ON S
1 25 N O M I N A L S I Z E P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 139.70 139.70 126.88 140.20 Norm Thick (mm) = 5.00 3.00 1.63 7.65 Norm Mean I.D. (mm) = 129.70 133.70 123.62 124.90 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min0
0
1
0.5
2
1.5
2.5
3000 6000 9000 12000 15000
PRES
SUR
E D
RO
P kP
a/m
ASTM A 53 SCHEDULE 40AS 1432 COPPER (Grade B)
200 N OMI N A L P IP E S IZE D IME N S I ON S
200 N OMI N A L S IZE P IP E
ORRFIRE® LIGHTAS 1477 CPVC (Class 12)
ASTM A 53 ORRFIRE® AS1432 Copper AS1477 CPVC Sch 40 Light (Grade B) (Class 12) Mean O.D. (mm) = 219.10 219.10 203.00 225.30 Norm Thick (mm) = 7.11 4.80 2.03 12.30 Norm Mean I.D. (mm) = 204.88 209.50 198.94 200.70 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
6 | Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 | 7
00
4
2
8
6
10
100 200 400300 600500 700 800 900 1000
PRES
SUR
E D
RO
P kP
a/m
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
5 0 N OMI N A L P IP E S IZE D I ME N S IO N S
50 N O MIN A L S IZE P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 60.30 60.30 50.74 60.35 Norm Thick (mm) = 3.60 2.30 1.22 3.35 Norm Mean I.D. (mm) = 53.10 55.70 48.30 53.65 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
65 N OMIN A L P IP E S IZE D IME N S IO N S
65 N OMIN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 76.10 76.10 63.43 75.35 Norm Thick (mm) = 3.60 2.30 1.22 4.20 Norm Mean I.D. (mm) = 68.90 71.50 60.99 66.95 Surface roughness K = 4.50 4.50 1.50 1.50
00
2
1
3
5
7
4
6
8
200 400 800 1000 1200 1400 1600600 1800
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
00
2
1
4
3
5
6
7
200 400 800600 12001000 1400 1600 1800 2000 2200 2400
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
8 0 N OM I N A L P I P E S I Z E D I M E N S I O N S
8 0 N OM I N A L S I Z E P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 88.90 88.90 76.11 88.90 Norm Thick (mm) = 4.00 2.60 1.53 4.95 Norm Mean I.D. (mm) = 80.90 83.70 72.85 79.00 Surface roughness K = 4.50 4.50 1.60 1.50
00
2
1
4
3
5
500 1000 20001500 30002500
PRES
SUR
E D
RO
P kP
a/m
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
9 0 N OM I N A L P I P E S IZ E D I M E N S I O N S
9 0 N OM I N A L S I ZE P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 101.60 101.60 88.80 101.50 Norm Thick (mm) = 4.00 2.60 1.63 5.55 Norm Mean I.D. (mm) = 93.60 96.40 85.54 90.40 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
80 NOMiNal BOre PiPe Size
90 NOMiNal BOre PiPe Size
100 NOMiNal BOre PiPe Size
125 NOMiNal BOre PiPe Size
80 NOMiNal BOre PiPe Size DiMeNSiONS
90 NOMiNal BOre PiPe Size DiMeNSiONS
100 NOMiNal BOre PiPe Size DiMeNSiONS
125 NOMiNal BOre PiPe Size DiMeNSiONS
PRESSuRE DROP & FlOW RATES
14 | ORRFIRE® Product Catalogue
10 | Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 | 11
00
1
0.5
2
1.5
5000 19000 15000 20000 25000
PRES
SUR
E D
RO
P kP
a/m
ASTM A 53 SCHEDULE 40
250 N OM IN A L P IP E S IZE D I ME N S IO N S
2 50 N O MIN A L S IZE P I P E
ORRFIRE® LIGHT AS 1477 CPVC (Class 12)
ASTM A 53 ORRFIRE® AS1432 Copper AS1477 CPVC Sch 40 Light (Grade B) (Class 12) Mean O.D. (mm) = 273.10 273.10 0.00 280.40 Norm Thick (mm) = 9.27 4.80 0.00 15.35 Norm Mean I.D. (mm) = 254.56 263.50 0.00 249.70 Surface roughness K = 4.50 4.50 0.00 1.50
FLOW RATE Litres /Min
00
1
0.4
0.6
0.8
0.2
1.6
1.4
1.2
4000 8000 1600012000 24000 2800020000 32000
PRES
SUR
E D
ROP
kPa/
m
ASTM A 53 SCHEDULE 40
300 N OMIN A L P IP E S IZ E D IME N S ION S
300 N OMIN A L S IZ E P I P E
ORRFIRE® LIGHT AS 1477 CPVC (Class 12)
ASTM A 53 ORRFIRE® AS1432 Copper AS1477 CPVC Sch 40 Light (Grade B) (Class 12) Mean O.D. (mm) = 323.90 323.90 0.00 315.45 Norm Thick (mm) = 10.31 6.40 0.00 17.20 Norm Mean I.D. (mm) = 303.28 311.10 0.00 281.05 Surface roughness K = 4.50 4.50 0.00 1.50
FLOW RATE Litres /Min
Need more information? Get the complete suite of Orrcon ORRFIRE brochures.
ORRCON “ORRFIRE” RANGE OF FIRE PROTECTION PIPE
COMPLIANCE WITH AUSTRALIAN STANDARDS
NOMINAL SIZE DN MM WALL THICKNESS MM COMPLIANCE WITH AS 4118 PART 2.1 FIRE SPRINKLERS
COMPLIANCE WITH AS 2419 HYDRANTS
S.S.L. APPROVAL LISTING NO’S
APPROVED FINISH ALLGAL, SMARTCOTE, H.D.G.
HOT DIP GALV. ONLY afp
25 2.0 Y - 1529 1640 1641
2.6 Y - 1510 1508
3.2 Y - 1530 1509 1511
32 2.0 Y - 1529 1640 1641
2.6 Y - 1510 1508
3.2 Y - 1530 1509 1511
40 2.3 Y - 1529 1640 1641
2.9 Y - 1510 1508
3.2 Y - 1530 1509 1511
50 2.3 Y - 1529 1640 1641
2.9 Y - 1510 1508
3.6 Y - 1530 1509 1511
65 2.3 Y - 1529 1640 1641
3.04 min. Y Y 1529
3.2 Y Y 1510 1508
3.6 Y Y 1530 1509 1511
80 2.6 Y - 1529 1640 1641
3.04 min. Y Y 1529
3.2 Y Y 1510 1508
4.0 Y Y 1530 1509 1511
100 2.3 Y - 1529
2.5 Y - 1529 1528
3.04 min. Y Y 1529 1528
3.2 Y Y 1640 1641
3.6 Y Y 1510 1508
4.5 Y Y 1530 1509 1511
5.4 Y Y 1530
125 3.0 Y - 1640 1641
3.5 min. Y Y 1510
5.0 Y Y 1530 1509 1511
150 2.77 Y - 1529
3.00 Y - 1529 1528
3.5 min. Y Y 1529 1640 1641 1508
5.0 Y Y 1530 1509 1511
5.4 Y Y 1530
200 4.8 Y Y 1529 1510
250 4.8 Y Y 1529 1510
������������������������������
����������������������������
�������������������������
������������������������ �����������������
���������������������
�����������������������
����������
���������������������������
�����������������
��������������
������������������� �
������������
����������������������
�����������������
�������������������������
������������������������� ���������
����������������������� �
������ �
�������������������������
���������������
������������������
��������������������������������
�������������������������
�����������������������
������������������
����������������������
�����������������
���������������������������������
���������������������������������
���������������������������������
���������
�������������������������� ������������
������������������������� �����������������
�������������������
������������������������
���������������������
�����������������������
��������������������
��������������������������
������������������
��������������
�����������������
ORRFIRE
SMARTCOTE PAINTED PIPE
ORRFIRE
ALLGAL ELECTRO-GALVANISED SPRINKLER PIPE
ORRFIRE
HOT DIP GALVANISED PLUMBING & HYDRANT PIPE
8 | Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 | 9
00
2
1
4
3
5
500 1000 20001500 3000 3500 40002500
PRES
SUR
E D
RO
P kP
a/m
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
1 00 N O MI N A L P IP E S IZ E D IM E N S ION S
1 0 0 N O MIN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 114.30 114.30 101.48 114.30 Norm Thick (mm) = 4.50 2.50 1.63 6.30 Norm Mean I.D. (mm) = 105.30 109.30 95.22 101.70 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
00
1
0.5
2
1.5
2.5
3
3.5
1000 2000 40003000 60005000 7000 8000 9000
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
1 5 0 N O M I N A L P I P E S I ZE D I M E N S I O N S
1 5 0 N O M IN A L S I Z E P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 165.10 165.10 152.25 160.25 Norm Thick (mm) = 5.00 3.00 2.03 8.80 Norm Mean I.D. (mm) = 155.10 159.10 148.19 142.65 Surface roughness K = 4.50 4.50 1.50 1.50
00
2
2.5
0.5
1
1.5
4
3
3.5
4.5
500 1000 20001500 30002500
PRES
SUR
E D
RO
P kP
a/m
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
12 5 N OM I N A L P I P E S I Z E D IM E N S I O N S
1 25 N O M I N A L S I Z E P I P E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 139.70 139.70 126.88 140.20 Norm Thick (mm) = 5.00 3.00 1.63 7.65 Norm Mean I.D. (mm) = 129.70 133.70 123.62 124.90 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min0
0
1
0.5
2
1.5
2.5
3000 6000 9000 12000 15000
PRES
SUR
E D
RO
P kP
a/m
ASTM A 53 SCHEDULE 40AS 1432 COPPER (Grade B)
200 N OMI N A L P IP E S IZE D IME N S I O N S
200 N OMI N A L S IZE P IP E
ORRFIRE® LIGHTAS 1477 CPVC (Class 12)
ASTM A 53 ORRFIRE® AS1432 Copper AS1477 CPVC Sch 40 Light (Grade B) (Class 12) Mean O.D. (mm) = 219.10 219.10 203.00 225.30 Norm Thick (mm) = 7.11 4.80 2.03 12.30 Norm Mean I.D. (mm) = 204.88 209.50 198.94 200.70 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
150 NOMiNal BOre PiPe Size
200 NOMiNal BOre PiPe Size 300 NOMiNal BOre PiPe Size
250 NOMiNal BOre PiPe Size
150 NOMiNal BOre PiPe Size DiMeNSiONS
200 NOMiNal BOre PiPe Size DiMeNSiONS
250 NOMiNal BOre PiPe Size DiMeNSiONS
300 NOMiNal BOre PiPe Size DiMeNSiONS
8 | Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 Orrcon Orrfire Pressure Drop & Flow Rates Version 1 Mar 2005 | 9
00
2
1
4
3
5
500 1000 20001500 3000 3500 40002500
PRES
SUR
E D
RO
P kP
a/m
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
1 00 N O MI N A L P IP E S IZ E D IM E N S ION S
1 0 0 N O MIN A L S IZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 114.30 114.30 101.48 114.30 Norm Thick (mm) = 4.50 2.50 1.63 6.30 Norm Mean I.D. (mm) = 105.30 109.30 95.22 101.70 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
00
1
0.5
2
1.5
2.5
3
3.5
1000 2000 40003000 60005000 7000 8000 9000
PRES
SUR
E D
RO
P kP
a/m
FLOW RATE Litres /Min
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
1 5 0 N O M I N A L P I P E S I ZE D I M E N S I O N S
1 5 0 N O M I N A L S I Z E P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 165.10 165.10 152.25 160.25 Norm Thick (mm) = 5.00 3.00 2.03 8.80 Norm Mean I.D. (mm) = 155.10 159.10 148.19 142.65 Surface roughness K = 4.50 4.50 1.50 1.50
00
2
2.5
0.5
1
1.5
4
3
3.5
4.5
500 1000 20001500 30002500
PRES
SUR
E D
RO
P kP
a/m
AS 1074 MEDIUMAS 1432 COPPER (Grade B)
12 5 N OM IN A L P IP E S IZE D IM E N S I ON S
1 25 N O MI N A L S I ZE P IP E
ORRFIRE® EXTRA LIGHTAS 1477 CPVC (Class 12)
AS 1074 ORRFIRE® AS1432 Copper AS1477 CPVC Medium Extra Light (Grade B) (Class 12) Mean O.D. (mm) = 139.70 139.70 126.88 140.20 Norm Thick (mm) = 5.00 3.00 1.63 7.65 Norm Mean I.D. (mm) = 129.70 133.70 123.62 124.90 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min0
0
1
0.5
2
1.5
2.5
3000 6000 9000 12000 15000
PRES
SUR
E D
RO
P kP
a/m
ASTM A 53 SCHEDULE 40AS 1432 COPPER (Grade B)
200 N O MI N A L P IP E S IZ E D IME N S I O N S
200 N O MI N A L S IZ E P IP E
ORRFIRE® LIGHTAS 1477 CPVC (Class 12)
ASTM A 53 ORRFIRE® AS1432 Copper AS1477 CPVC Sch 40 Light (Grade B) (Class 12) Mean O.D. (mm) = 219.10 219.10 203.00 225.30 Norm Thick (mm) = 7.11 4.80 2.03 12.30 Norm Mean I.D. (mm) = 204.88 209.50 198.94 200.70 Surface roughness K = 4.50 4.50 1.50 1.50
FLOW RATE Litres /Min
PRESSuRE DROP & FlOW RATES
15we’ll see it through
although all care has been taken in the preparation of information in this brochure,
Orrcon Operations Pty ltd cannot accept liability for errors or omissions, or for the use
of this brochure. You should always satisfy yourself as to the accuracy of the information and
applicability to your circumstances.
OrrFire® Product Catalogue Orr0011 Printed September 2012
Quality ISO 9001
we’ll see it through
ORRFIRE® Product Catalogue
images are for illustration purposes only.
Orrcon Operations Pty ltd aBN 92 094 103 090Head Office - 121 evans road, Salisbury, QlD 4107Telephone (07) 3274 0500 Facsimile (07) 3274 0517For your nearest stockist call 1300 650 303Orrcon Steel 1300 OrrCON (1300 677 266)email [email protected] Website www.orrconsteel.com.au
Distributed by