our - blastandballistics.com · ral colours for internal and external applications ... model bbbv...

6
1 Blast and Explosion Release Vents Designed primarily for commercial and military environments PPC factory applied finishes in a range of RAL colours For internal and external applications Can be re used following a forced opening Available in small, large and purpose made sizes Factory calibrated and adjustable after installation to accommodate increased operational requirements Typical Top Hinged Blast Vents Typical section detail for opening release vents– See table below for available sizes Technical Data Sheet TDSBB 1018 Also ask about our ‘Fixed Blast Louvers’ [email protected]

Upload: truongnhi

Post on 08-Oct-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: our - blastandballistics.com · RAL colours For internal and external applications ... Model BBBV 1003 Spark proof adjustable latching Louvered infill panel providing air ... •

1

Blast and Explosion

Release Vents

Designed primarily for commercial and

military environments

PPC factory applied finishes in a range of

RAL colours

For internal and external applications

Can be re used following a forced opening

Available in small, large and purpose

made sizes

Factory calibrated and adjustable after

installation to accommodate increased

operational requirements

Typical Top Hinged Blast Vents

Typical section detail for opening release vents–

See table below for available sizes

Technical Data Sheet

TDSBB 1018

Also ask about

our ‘Fixed Blast

Louvers’

[email protected]

Page 2: our - blastandballistics.com · RAL colours For internal and external applications ... Model BBBV 1003 Spark proof adjustable latching Louvered infill panel providing air ... •

2

Frame profile

Available as steel and aluminium profile

Minimum frame depth/wall thickness 70mm

Finishes

Factory applied Polyester Powder Coat

Available sizes

Min 500mm x 500mm

Max 1200mm x 2400mm

With additional units - indefinite

Overall thicknesses

Generally 70mm overall – other sizes by special order

Operating/Release pressures

Adjustable to order but min. 0.0065bar

Can be re set after installation for higher values

Options

Thermally broken

Weights

Frame profiles approx. 3kg/m - 15kg/m

Packing

Supplied in standard or international crates for dispatch

Top hinged vent in

closed position

Available as both top and bottom hinged vent panel

Top hinged vent

opening under blast

loading

Top hinged vent can be

re set after explosion

Ordering and Calibration:

When ordering please state finished overall width and height in millimetres.

State the minimum required opening/release pressure. This will be factory set. Note – it may be

necessary when stating this to consider local climatic conditions to allow for wind and other salient

external effects which may exceed the release pressure and cause the vent to open when not required.

The release pressure can also be checked, calibrated and adjusted for higher or lower values even after

installation.

Under normal operating conditions the vent can be closed after having been released and will be ready

to operate again upon closure. It should be checked for correct operation however to ensure the blast

pressure that the unit has vented has not been greater than anticipated and in consequence could have

damaged or misaligned the vent unit.

Blast and Explosion Release Vent and Louvre data

Page 3: our - blastandballistics.com · RAL colours For internal and external applications ... Model BBBV 1003 Spark proof adjustable latching Louvered infill panel providing air ... •

3

Top hinged vent opening

under blast loading

Model BBBV 1001

Spark proof adjustable latching

Opaque solid infill panel

Factory prepared for installation

FM approved blast and explosion

latching system (Factory Mutual)

Top hinged vent opening

under blast loading

Model BBBV 1002

Spark proof adjustable latching

Clear infill panel providing natural

light where required

Factory prepared for installation

FM approved blast and explosion

latching system (Factory Mutual)

Top hinged vent opening

under blast loading

Model BBBV 1003

Spark proof adjustable latching

Louvered infill panel providing air

flow where required

Factory prepared for installation

FM approved blast and explosion

latching system (Factory Mutual)

Page 4: our - blastandballistics.com · RAL colours For internal and external applications ... Model BBBV 1003 Spark proof adjustable latching Louvered infill panel providing air ... •

4

Manufactured to customer’s specifications in

single and multiple configurations depending

upon blast loading and building design

Page 5: our - blastandballistics.com · RAL colours For internal and external applications ... Model BBBV 1003 Spark proof adjustable latching Louvered infill panel providing air ... •

5

The system is designed to accept opaque, clear, transparent, translucent and also louvered ventilation panels

The Blast and Explosion Vents and Blast and Explosion

Louvers are designed primarily to release overpressure from

within a building or internal area. They are often required

however to allow airflow at other times especially in the

case of plant and machinery. The Blast and Explosion

Louvres when fitted with the Blast Louver panel will do just

that until such time as the pressure needs to be released.

Pressure that is not aspirated through the Blast Louver will

operate the release mechanism and the Blast and Explosion

Louvre will release the panel and allow it to open.

The Blast and Explosion Vents and Louvers are also available

with various types of solid insulated and also clear glazed

panels. Allowing light transfer or not as the case may be. The

frame system of both the Blast and Explosion Vent and Blast

and Explosion Louver is thermally broken and is

complimented with the use of thermally broken infill panels.

A wide range of powder coat colour finishes is also available.

Products are factory finished and packaged ready for

dispatch.

The Blast and Explosion Vents can also be upgraded to

provide ballistic protection. This helps protect against

fragmentation which can be produced in commercial

environments. As one example these Blast and Explosion

Vents have been used to protect workers in areas such as

the laboratory testing of high speed revolving parts or

pressure pipework systems.

Page 6: our - blastandballistics.com · RAL colours For internal and external applications ... Model BBBV 1003 Spark proof adjustable latching Louvered infill panel providing air ... •

6

Installation and Maintenance:

The unit is factory pre-assembled and after offering the frame into the prepared structural opening it is

secured using proprietary frame or machine screw fixings

The system can be sealed around its perimeter for weather tightness using proprietary sealants

The system is lightweight and can sometimes remove the need to use other expensive handling

equipment during installation

After installation the unit can also be checked for operating release pressures and adjusted if necessary

to accommodate increased or decreased blast/explosion threats from within the building

Unless the previous blast/explosion has been particularly onerous for the unit it will simply close and is

ready for operation – no need to replace the unit. Check that the unit has correctly re latched and is not

damaged

The unit is already factory calibrated ready for installation

Installation is simple and reduces site cost

The unit is lightweight and is often installed using one person

The unit requires little maintenance. Check for correct operation, clean and check release pressure if

required

The centre panel of the unit is also available in clear finish to allow daylight transmission if required

• Paper Process (solvent use/storage)

• Laboratory Test Facilities

• Hospitals (gas and/or flammable storage areas)

• Brewery Facilities (grain storage/processing)

• Fossil Fuel Plants (coal dusts)

• Food Processing (airborne dust)

• University Labs (chemical lab store rooms)

• Grain Milling Facilities (airborne dusts)

• Nuclear Power Stations

• Printing Companies (solvent use/storage)

• Chemical Production

• Petroleum Industry

• Paint, Varnish Manufacturers

• Energy/ Mining Industry

• Co-Generation Plants

• Recycling Centres

• Sewage Treatment (by-product recycling)

• Automotive (air bag, mfg. Plant lines)

• Grinding/Pulverizing processes (airborne dusts)

• Ink Manufacturers

Typical Areas of Application

Email: [email protected]