1 Outside Plant Outside Plant Telephone Cable Testing & Fault Locating Telephone Cable Testing & Fault Locating Dynatel TM Systems Enter On Off ISDN 8 7 dB Auto 0 9 6 5 V 1 mA 2 4 3 S/N: 19970007 c 1997 3M Ver 1.01 USA On Off Setup Help Welcome Dynatel 965DSP TM Subscriber Loop Analyzer/TDR Dynatel 965DSP TM Prepared By: Roger C. Valencia US and International Technical Service Engineer 3M Test & Measurement Systems 3M Austin Center Austin, TX, USA - January 1999

Upload: truongphuc

Post on 21-Feb-2018

223 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

1

Outside PlantOutside PlantTelephone Cable Testing & Fault LocatingTelephone Cable Testing & Fault Locating

DynatelTM Systems

Enter

OnOff

ISDN87

dB Auto0

9

65

V1

mA2

4

3

S/N: 19970007c 1997 3MVer 1.01USA

OnOff

Setup Help

WelcomeDynatel 965DSPTM

Subscriber Loop Analyzer/TDR

Dynatel 965DSPTM

Prepared By:Roger C. ValenciaUS and International Technical Service Engineer3M Test & Measurement Systems3M Austin CenterAustin, TX, USA - January 1999

Page 2: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

2

480 TURBO

YK 749

V O

XYZ TelcoMDF

Cable Vault

Direct Buried Cable System

Manholes

X-ConnectBoxes

M a n h o l e s

A e r i a l C a b l e S y s t e m

The Telephone Outside Plant [OSP]

Central Office

U n d e r g r o u n d C a b l e S y s t e m

Page 3: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

3

TSPS *Vertical Frame Horizontal Frame

JumperWires

Switch

CAMA **

* T rafficS erviceP ositionS ystem

** C entralizedA utomaticM essageA ccounting

Operator-assistedlong distance calls

Computerizedbilling equipmentfor long distancecalls

Subscriber

ProtectorBox

TipCables

CableVault

Feeder Cable

UndergroundPlant

Distribution Cable

AerialPlant Subscriber

X-Connect Boxes

DistributionCables

Direct-Buried Plant Direct-Buried Drop Wire

The Telephone Outside PlantThe Telephone Outside Plant[ OSP ][ OSP ]

COCOMDFMDF

Protectors

Manhole

Manhole

Page 4: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

4

The

Telephone Cable[Definition]

It is one of several other types of communication facilities or media which is generally made up of paired, insulated copper conductors called TIP [A] and RING [B].

A cable can consist a few pairs, hundreds of pairs or thousands of pairs and the conductors can be of different sizes or gauges depending upon system requirements.

Other types of Communication Facilities

OPEN WIRE SYSTEMS [ Telegraph ]

COAXIAL SYSTEMS [ CATV ]

RADIO SYSTEMS [ Microwave, Cellular ]

COMMUNICATION SATELLITES [ Disk ]

FIBER OPTIC SYSTEMS

Page 5: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

5

TheTelephone Cable

[Basic Construction]

Outer Cable Jacket [ Plastic ]

Air or Jelly-filled

Conductor Insulation [ Plastic, Pulp or Paper ]

Copper Conductors

RING [ B ]

TIP [ A ]

Cable Shield[Corrugated Aluminum ]

Page 6: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

6

The origin of the name Tip [A] and Ring [B]

Shell Sleeve

Insulators Tip [A]

Ring [B]Insulator

Tip [A]

Ring [B]

Sleeve

Page 7: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

7

The

Telephone Cable[ Electrical Representation ]

Cable Shield / Gnd

Cable Shield / Gnd

T [A] - GndCapacitance

T [A] - GndCapacitance

T [A] - GndCapacitance

T [A] - GndCapacitance

T [A] - GndCapacitance

R [B] - GndCapacitance

R [B] - GndCapacitance

R [B] - GndCapacitance

R [B] - GndCapacitance

R [B] - GndCapacitance

T [A] - R [B]Mutual

Capacitance

T [A] - R [B]Mutual

Capacitance

T [A] - R [B]Mutual

Capacitance

T [A] - R [B]Mutual

Capacitance

T [A] - R [B]Mutual

Capacitance

Tip [A]

Ring [B]

Page 8: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

8

Effect of Cable Resistance to Signal Transmission

Transmit Side

Receive Side

Cable Shield

Cable Shield

0 dBm[ 1 mw ]

- 8.5 dBm

Note:

In a pure resistive circuit, the transmitted signal will be

attenuated but its original shape is maintained. There will

be no distortion of the signal.

Tip [A]

Ring [B]

Page 9: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

9

Effect of Cable Resistance and Capacitance to Signal Transmission

Note:

In a circuit where both resistance and capacitance exist, the transmitted tones were attenuated and their original shapes were also altered or changed. In other words, the signal became distorted.

High frequencies normally suffers most because of the combined filter effect of cable resistance and capacitance. In the illustration, the high frequency tone was almost totally absorbed by the added capacitance of the cable.

Tip [A]

Ring [B]

Transmit Receive

Cable Shield

- 16.5 dBm

0 dBm[ 1 mw ]

Page 10: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

10

R E S I S T A N C E[ D e f i n i t i o n ]

It is a natural characteristic of any conductor (i.e. Copper, Aluminum, Nickel, Silver, Gold, etc.) which opposes the flow of electrical current through it.

Electric current

Conductor Resistance

IN OUT

BatteryConductor Resistance

Available electric current from the battery

Actual current flowing through the circuit due to the conductor resistance.

Conductor

Page 11: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

11

OHM

Unit of measure for Resistance

Commonly used units:

Ohm = 0 to 1

Ohms = 2 to 999

Kilo-Ohms ( K ) = 1000 to 999,999

Mega-Ohms ( M ) = 1,000,000 to 999,999,999

Giga-Ohms = 1,000,000,000

Page 12: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

12

Electrical Length of a Conductor

Ohmmeter

Conductor

Resistance

Plastic Insulation

It is the resistance of a conductor in OHMS measured at a certain temperature in oFarenheit or oCentigrade

and then converted into DISTANCE (length).

Copper W I R E

Page 13: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

13

Physical Length of a Conductor

0 1 2 3 4 5 6 7 8 9

It is the length measured with the use of a measuring device like a WHEEL or a RULER Tape.

ConductorInsulation

Measuring Device

Page 14: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

14

Conductor Resistance To DistanceConversion Table

Gauge [Size]

AWG ( mm )

Conductor Length

per Ohm

19 AWG ( 0.91 mm ) 124.24 ft. ( 37.87 m )

22 AWG ( 0.64 mm ) 61.75 ft. (18.82 m)

24 AWG ( 0.51 mm ) 38.54 ft. ( 11.75 m )

26 AWG ( 0.41 mm ) 24.00 ft. ( 7.32 m )

28 AWG ( 0.32 mm ) 15.08 ft ( 4.60 m )

Formulas:

1. For cable temperatures ABOVE 68 oF [ 20oC ] : Ft = Fa [ 1 - 0.00218 ( t - 68 ) ]

2. For cable temperature BELOW 68 oF [ 20oC ] : Ft = Fa [ 1 + 0.00218 ( t + 68 ) ]Where:

Ft = Feet / Meters per Ohm @ temperature t ( oF / oC )

Fa = Feet / Meters per Ohm @ temperature 68 oF / 20 oC

(see table above).

Page 15: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

15

The “ TWIST ” Factor

Cable Length

Cable Shield

Spiral twisting of conductors

Pair Length

The“ Twist ”Factor

3 %

Outer Plastic Sheath

Note:

The twisting of the conductors inside the cable makes the physical and electrical length of the pair about 3% longer than cable.

Ex.: If the electrical length of a pair is 103 feet or meters, this can be translated to 100 feet or meters of cable length.

Page 16: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

16

Factors That Affect Resistance

1. Length:

The shorter the conductor, the lower its resistance.

The longer the conductor, the higher its resistance.

2. Gauge (Size):

The bigger the conductor, the lower its resistance.

The smaller the conductor, the higher its resistance.

3. Temperature:

The lower the conductor’s temperature, the lower its resistance.

The higher the conductor’s temperature, the higher its resistance.

Therefore:

The Length of a conductor is a factor of Gauge (Size) and Temperature.

Page 17: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

17

Loop Resistance

Strap

Ohmmeter

Tip [A] - R1

Ring [B] - R2

Loop Resistance = R1 + R2

Resistance to strap = R1 + R2

2

Page 18: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

18

Resistive Balance TestMeasurement #1

Strap

Strap

Strap

Measurement #2

Measurement #3 Tip [A]

Ring [B]

Tip [A]

Ring [B]

Tip [A]

Ring [B]

Note: For a normal cable ---a) Measurement #1 should be equal to Measurement #2 (If they differ by 10% or more, a “partial open”

exist in either Tip [A] or Ring [B] or both).

b) Measurement #3 = Measurement #1 + Measurement #2

Shield

Shield

Shield

Page 19: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

19

Rt = R1 + R2 = 10 + 10 = 20 Ohms

1 R1 + R2 10 + 10 20

Rt R1 x R2 10 x 10 100

Rt 100

1 20=

= = or

R1

(10)

= 5 Ohms

=

More About Resistors

R2

(10)

R2

(10)

R1

(10)

Page 20: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

20

Wheatstone (Resistance) Bridge[ Basic Concept]

R1=120

R2=120 R4=120

R3=120

A

B

Galvanometer

NULL

BatteryBattery

Conditions for NULL

R1 R3

=

R2 R4

12VDC 12VDC

6VDC 6VDC

6VDC6VDC

Page 21: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

21

Wheatstone Bridge[ Precision Ohmmeter ]

Tip [A]

Ring [B]

RL1

RL2

StrapR3R1

R2 R4 (Variable )

G

B

A

BatteryBattery

Note:

R1 & R2 are fixed and ratio is known

RL1 + RL2 = Loop resistance [ Tip (A) & Ring (B) ]

R4 = Variable Resistor

G = Galvanometer [ NULL Meter ]

R1 R3

R4R2

Basic Wheatstone Bridge

Conditions for NULL

R1 R3

=

R2 R4B

A

NULL Meter

Page 22: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

22

Resistance Fault Locateusing a Wheatstone Bridge

[ Basic Concept ]

DTF (Distance-To-Fault)

DTS (Distance-To-Strap) = 1000 meters

STF (Strap-To-Fault)

A

R1 R3

T1 T2

A

B

A

B

T1 T2

R1 R3

R2 R4T1 T2

G

1000 meters

Fault

0 % 100 %

75 %

Dynatel 965 Subscriber Loop Analyzer

Slider Arm

Note: If the bridge nulls at 75 % of DTS (1000 meters) then -DTF = 75% of 1000 m = 750 mSTF = 25% of 1000 m = 250 m

Faulted ConductorFault

G

Conditions for NULLR1 R3

=R2 R4

R2

R3

R4

R1

Page 23: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

23

CAPACITANCEIt is the electrical property of a device called “Capacitor” which is created when two or more metallic plates or conductors are placed close to but electrically insulated from each other.

Capacitance permits the storage of electrical energy which means that the capacitor can be charged or discharged similar to a rechargeable battery.

Commonly used dielectric materiasls

1. Paper2. Ceramic3. Mylar4. Polyester5. Mica6. Electrolyte

Plate #1

Plate #2

ConnectingLead

ConnectingLead

Basic Construction of a Capacitor

Dielectric [ Insulator ]

Page 24: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

24

Common types of Capacitors

1. Mica

2. Paper

3. Polyester

4. Ceramic

5. Electrolytic

0.022/250

5% WIM

AM

KC

4

0.0022

50V

1000

uf 1

6v10

00

0.1 ufd. 350VDC

Mica Trimmercapacitor Tubular

Paper capacitorPolyestercapacitor

Ceramiccapacitor

Electrolyticcapacitor

Page 25: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

25

Factors Affecting Capacitance

1. The Larger the plates, the higher the capacitance.2. The closer the plates, the higher the capacitance.3. Solid dielectric (insulation) materials increases capacitance compared to air.

Larger Plates

Smaller Plates

Closer Gap

Wider Gap

Solid Dielectric

Air Dielectric

Page 26: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

26

How a Capacitor Works

12 V

12 V

Charging the capacitor

Charge retained

Charger disconnected 12 V

12 Vlamp

Lamp lights up until capacitor is fully discharged.

Page 27: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

27

More about Capacitors

C1 = 1uF

C2 = 1uF

Ct = C1 + C2 = 2uF

= =1

Ct

1 + 1

1

C1 + C2

C1 x C2

= or1

Ct

2

1

Ct = = 0.5 uF1

2

C1 = 1uF C2 = 1uF

Page 28: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

28

Capacitances on a telephone pair

Tip [A]

Ring [B]

Shield

Shield

Tip [A]

Ring [B] C1

C2 C3

Mutual Capacitance

Ring [B] to GroundCapacitance

Tip [A] to GroundCapacitance

Page 29: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

29

Capacitances in a telephone cable

Ring [B] Tip [A]

Tip [A]

Ring [B]Shield

Page 30: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

30

FARADUnit of measure for capacitance

Commonly-used capacitance units:

Microfarad (uF) = 1 millionth of a FARAD

Nanofarad (nF) = 1 thousanths of a Microfarad

Picofarad (pF) = 1 millionth of a Microfarad

Page 31: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

31

Standard Capacitances Of Telephone Cables

Type MutualTip[A] / Ring[B]

To Ground

Aircore

Jelly-Filled

2-Pair Drop

5-Pair Drop

0.083 uF/Mile[ 0.052 uF/Km ]

0.125 uF/Mile[ 0.078 uF/Km ]

0.140 uF/Mile[ 0.087 uF/Km ]

0.155 uF/Mile[ 0.096 uF/Km ]

0.150 uF/Mile[ 0.093 uF/Km ]

0.083 uF/Mile[ 0.052 uF/Km ]

0.083 uF/Mile[ 0.052 uF/Km ]

0.083 uF/Mile[ 0.052 uF/Km ]

Page 32: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

32

How A Uniform Mutual Capacitance Of A Telephone Cable Pair Is Achieved Irrespective Of The Different Conductor Sizes (Gauges)

D

D DD

D

D

‘D’istance = the same

Insulation Thickness = the same

Size/Gauge = not the same

Mutual Capacitance = not the same

‘D’istance = not the same

Insulation Thickness = the same

Size/Gauge = not the same

Mutual Capacitance = not the same

‘D’istance = not the same

Insulation Thickness = not the same

Size/Gauge = not the same

Mutual Capacitance = the same

Tip[A] Ring[B]

Tip[A] Ring[B]

Tip[A] Ring[B]

Tip[A] Ring[B]

Tip[A] Ring[B]

Tip[A] Ring[B]

Page 33: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

33

How the 965DSP measures capacitance

AC current

R = ?

XL = 0

XC = ?

Lo-HiFrequency Sweep

R = ?

XL = 0

1. The 965DSP transmits a Lo-Hi frequency sweep at a specified voltage across the circuit where the amount of current flow is determined. Once the amount of circuit current is known, circuit impedance is then calculated.

2. Once the circuit impedance is known, the value of the two unknown factors R = ? Ohms and XC = ? Ohms are calculated with the use of sophisticated mathematical process.

3. When the value of XC is found, it is translated into capacitance and then into distance based on pre-programmed Capacitance-To-Distance table in the software.

Example:

Impedance = 600 ohms

R = 40 ohms

XC = 560 ohms = 0.083uF = 1 mile (length of cable)

XL = 0 ohms (insignificant in this example)

R = resistance of the conductors to AC

current in ohms.

XL = Inductive reactance - opposition of a

coil to AC current in ohms.

XC = Capacitive reactance - opposition of

a capacitor to AC current in ohms.

R + XL + XC = Impedance in ohms.

Voltage

Page 34: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

34

How length of Tip[A] is measured with the 965DSP “OPEN” Meter

C1a C1b C1c

C2a C2b C2c

C3a C3b C3c

C2

C3 C3 C2

Note:

When the length of Tip[A] is being measured, the Red test lead is shorted to Green (Shield/Ground) through an internal switch thus grounding the Ring[B]conductor.

The total capacitive reactance of C3 and C2 (in ohms) translated into distance (in feet or meters) represents the length of Tip[A].

Lo-HiFrequency Sweep

Red

Blk

GrnShieldG

rn

Ring[B]

Tip[A]

Red

Blk

Tip[A] Ring[B] Tip[A]

Page 35: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

35

How length of Ring[B] is measured with the 965DSP “OPEN” Meter

Tip [A] Ring[B]

Shield

Short C1

C2

Shield

C2C1

C1a C1b C1c

C2a C2b C2c

C3a C3b C3c

Note:

When the length of Ring[B] is being measured, the Black test lead is shorted to Green (Shield/Ground) through an internal switch thus grounding the Tip[A]conductor.

The total capacitive reactance of C3 and C1 (in ohms) translated into distance (in feet or meters) represents the length of Ring[B].

Lo-HiFrequency Sweep

Red

Blk

GrnShieldG

rn

Ring[B]

Tip[A]

Red

Blk

Page 36: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

36

How Mutual length is measured with the 965DSP “OPEN” Meter

Note:

‘Mutual’length is measured between ‘Tip [A]’and ‘Ring[B]’with all the test leads floating.Also take note that‘C1’and ‘C3’are connected in series through the cable shield and then in parallel to‘C2’. The ‘Mutual’capacitance will then be ‘C2’plus the series capacitances of ‘C1’and ‘C3’.

Tip [A] Ring[B]

C3

C2

Cable Shield

C1

C1a C1b C1c

C2a C2b C2c

C3a C3b C3c

Lo-HiFrequency Sweep

Red

Blk

GrnShieldG

rn

Ring[B]

Tip[A]

Red

Blk

Page 37: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

37

Categories & Types Of Cable Faults

B. Capacitance Faults:1. Complete Open

2. Partial Open

3. Dirty Open

4. Split

A. Resistance Faults:1. Ground

2. Short

3. Cross

4. Battery Cross

Page 38: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

38

A: Resistance Faults

2. SHORT :

A fault between ‘Tip [A]’and ‘Ring [B]’conductors.

Solid Short

Water

Tip [A]

Ring [B]Short due to water

Schematic diagramSchematic diagram

OR

1. GROUND :

A fault between ‘Tip [A]’and ‘Ground’, ‘Ring [B]’and ‘Ground’or both conductors and ‘Ground’.

Tip [A]

Ring [B]

Shield

Solid Ground Fault

Water

Ground Fault due to water

ShieldShield

Ground Fault

Schematic diagram

Solid Ground Fault

Schematic diagram

OR

Tip [A]

Ring [B]

Page 39: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

39

3. CROSS :

A fault between a non-working (pair under test) and another or other non-working pairs.

Note:

To locate a ‘CROSS’, the pairs involved must be identified, initially.

Resistance Faults( con’t )

Water

Resistive Cross fault due to water

4. Battery CROSS :

A fault between a working pair and a non-working pair (pair under test).

Note:

a) To locate a ‘Battery CROSS’, there is no need to identify the working pair. The fault locate procedure is the same as locating a ‘GROUND’ due to the battery’s internal resistance to ‘GROUND’

b) In a ‘Solid Cross Fault’, the voltage reading on the pair under test is quite high (the same or very close to the CO battery voltage) while in a ‘Non-solid CrossFault’the voltage reading is very much lower.

Water

-48 VDC

-7 VDC

OR

Solid Cross Fault

Pair # 1 - Working pair

Pair # 2 - Non-working(Pair under test)

-48 VDC

-46 VDC

Schematic diagram

Solid Cross Fault OR

Solid Cross Fault

Schematic diagram

Solid Cross Fault

Pair # 1 - Non-working

Pair # 2 - Non-working

OR

Pair # 1 - Non-working

Pair # 2 - Non-workingTip [A]

Ring [B]

Ring [B]

Tip [A]

Ring [B]

Tip [A]

Ring [B]

Tip [A]

Pair # 1 - Working pair

Pair # 2 - Non-working(Pair under test)

Ring [B]

Tip [A]

Ring [B]

Tip [A]

Ring [B]

Tip [A]

Ring [B]

Tip [A]

Resistive Cross fault due to water

Resistive Cross fault

Pair # 1 - Working pair

-48 VDC

-46 VDC

-48 VDC

-7 VDC

Page 40: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

40

B: Capacitance Faults

1. Complete OPEN:A fault where a conductor is cut off completely.

2. Partial OPEN:A fault where a high resistance path developed on a conductor. ( Ex. Corroding splice)

Tip [A]

Ring [B]

Schematic diagram

Complete OpenTip [A]

Ring [B]

Partial Open

Partial Open

Tip [A]

Ring [B]

Schematic diagram

Tip [A]

Ring [B]

Complete Open

Water

Page 41: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

41

B: Capacitance Faults(con’t)

3. Dirty OPEN:Any combination of a ‘RESISTANCE’and

‘CAPACITANCE’faults

Tip [A]

Ring [B]

Schematic diagram

Tip [A]

Ring [B]

Water

A: Complete OPEN and a SHORTD: Partial OPEN and a SHORT

B: Complete OPEN and a GROUNDE: Partial OPEN and a GROUND

Water

C: Complete OPEN and a CROSS

Open

ShortPartial Open

Ground

Ground

Ground

Partial Open

Complete Open

Short

Water

Schematic diagram

Schematic diagram

Cross Complete Open

Schematic diagram

Schematic diagram

Pair # 1

Pair # 2

Pair # 1

Pair # 2

Tip [A]

Ring [B]

Partial Open

Tip [A]

Ring [B]

Tip [A]

Ring [B]

Tip [A]

Ring [B]

Tip [A]

Ring [B]

Tip [A]

Ring [B]

Page 42: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

42

B: Capacitance Faults(con’t)

4. SPLIT:

A splicing error where one conductor of a pair (normally ‘Tip [A]’because they the same color) is spliced to ‘Tip [A]’of another pair.

Tip [A]

Ring [B]

Schematic diagram

Ring [B]

Tip [A]

Pair # 1

Pair # 2

Split

Ring [B]

Tip [A]

Tip [A]

Ring [B]Pair # 1

Pair # 2

Page 43: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

43

Cable FaultCable Fault--Locating ProcedureLocating Procedure

1. Fault Analysis:

- Analyze symptoms carefully.

- Determine the category and type of fault or faults.

2. Fault Locate to a Cable Section:

- Determine the faulted cable section and isolate other sections without fault.

- From a measured fault location, always consider the nearest access point (Splice,X-Connect box, or a Terminal) as the prime suspect.

3. Fault Locate (Pinpoint).

- Determine the exact physical length of the cable section under test and calibrate the test set to that length. (i. e. If the section length is 500 feet or meters, select “DTS (Distance-To-Strap) Known” in RFL Setup and enter this length).

- Use a separate good pair, as much as possible.

Note:

For short cable sections it is better to run your own “good pair” using a roll of MDF jumper wire rather than look for one in the cable.

4. Repair or Fix the Fault or Faults.

5. Verify that the line works.

Page 44: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

44

Cable Fault Analysis ProcedureCable Fault Analysis Procedure

1. Check and Measure possible Voltages (AC & DC) on the line:

a) between Tip[A] and Ring[B]

b) between Ring[B] and Ground

c) between Tip[A] and Ground

2. Check and Measure Insulation (Leakages) Resistances

a) between Tip[A] and Ring[B]

b) between Ring[B] and Ground

c) between Tip[A] and Ground

3. With the OPENS Meter, check the capacitance lengths of Tip[A] & Ring[B] and compare.

The lengths should be equal or within 10% of each other.

4. Perform a Resistance Balance Test using the Ohmmeter or Special Resistance Test in the Tool Box.

a) Strap Tip[A] and Ring[B] to Shield/Ground at the far-end.

b) Measure Tip[A] to Shield/Ground Resistance.

c) Measure Ring[B] to Shield/Ground Resistance.

d) Measure Loop Resistance (Tip[A] + Ring[B] ohms)

Note:

Measurements (b) and (c) should be equal or within 10% , otherwise an “open” or a “partial open” exists.

Page 45: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

45

Factors that can cause errors in fault locate measurementsFactors that can cause errors in fault locate measurements

1. Poor Connections will affect RFL measurements.a) Test Leads

b) Strap

Note:

A 1/4 (0.25) ohm resistance introduced into a 22AWG (0.61mm) conductor will constitute and error of about 16 feet (5 meters).

2. Incorrect assumption of conductor gauge (size) will affect RFL measurements.A one gauge higher or lower assumption will result into a 40% to 50% error.

3. In equalities of conductor resistances will affect RFL measurements.a) Variations of gauge created during the cable manufacturing process.

b) Unequal twisting of pairs.

c) Resistances introduces by connectors used during splicing.

d) Inequalities of temperature along the cable length.

4. Random distribution of moisture or water in the cable will affect OPEN measurements.

5. Induced currents (from Power lines, lighting and traction circuits) during the fault locate process will affect both RFL and OPEN measurements.

Page 46: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

46

95%OF ALL TELEPHONE CABLE FAULTS ARE LOCATED

IN AN ACCESS POINT

(ex: Splices, Terminals, Cross-Connect or Protector Boxes, etc.)

THE OTHER

5%CAN BE IN MID-SPAN.

This means that the access point closest to the fault locate measurement must be checked first before considering the fault to be in mid-span.

CRAFTSMAN’SCRAFTSMAN’SGOLDEN RULEGOLDEN RULE

Page 47: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

47

CABLE FAULT LOCATINGCABLE FAULT LOCATING

? It is “NOT” an “EXACT SCIENCE”.

? It is an “ART”.

? The name of the game is “SKILL”.

Page 48: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

48

Note:Leave the far-end open (do not strap). Connect the test leads as shown above. Press the OHMS key and write down the resistance readings between the following:

Tip[A] / Ring[B] =________________ OhmsRing[B] / Ground = ________________OhmsTip[A] / Ground =________________ Ohms

A reading of 3.3 Meg-Ohms or less is will affect service which can trigger a formal complaint from the Subscriber. To avoid the customer initiating a complaint, it is suggested that the fault must be located and fixed before the fault value goes down to 3.3Meg.At this same time, since a Capacitance Balance Test does not require putting a far-end strap, the same hookup above can be used to check for possible OPEN faults using an OPEN Meter.Tip[A] Length___________feet. Ring[B] Length ____________feet. Mutual Length _____________feet.

Fault Analysis Sheet 1(Use for Fault Diagnostics)

1. Insulation Test: Use this test to determine possible Resistance Faults like a SHORT, GROUND, CROSSor BATTERY CROSS.

Tip[A]

Ring[B]

Cable Shield / Ground

Black

Red

Green

Black

Red

Green

Page 49: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

49

Note:In this test, the continuity of conductors TIP[A] and RING [B] are measured and compared using Shield/Ground as a reference. This is to check for possible opens on the pair, like COMPLETE OPEN, PARTIAL OPEN, or DIRTY OPEN.Strap the far-end and connect the test leads, as shown above. Press the OHMS key and write down the resistance reading between the following:

Tip[A] / Ring[B] =________________ OhmsRing[B] / Ground = ________________OhmsTip[A] / Ground =________________ Ohms

If Tip[A] to Shield/Ground and Ring[B] to Shield/Ground resistances differ by 10% or more, an OPEN exists on the pair.

2. Resistance-Balance Test: This test is used to determine possible existence of Capacitance Faults on a pair, like a COMPLETE OPEN, PARTIAL OPEN or DIRTY OPEN.

Black

Red

Cable Shield / Ground

Strap

Tip[A]

Ring[B]

Black

Red

Green

Fault Analysis Sheet 2(Use for Fault Diagnostics)

Page 50: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

50

Page 51: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

51

Resistance Fault Locate (RFL) Hookups

Tip[A]

Ring[B]

Shield / Ground

Green

Yellow

Strap

Ground Fault

Separate Good Pair

965DSPRed

Black

965DSP

Green

Red

Black Shield / Ground

Tip[A]

Ring[B] - Good Conductor

Ground Fault

Strap

1. Ground: Option A: Using a Separate Good Pair

Option B: Single Pair (Single Good Conductor)

Pair Under Test

Page 52: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

52

Resistance Fault Locate (RFL) Hookups (con’t)

Tip[A]

Ring[B]

Green

YellowStrap

Short

Good Pair

965DSP

Red

Black

965DSP

Green

Red

Black Ring[B]

Tip[A]

Good conductor

Short

Strap

2. Short: Option A: Using a Separate Good Pair

Option B: Single Pair (Single Good Conductor)

Page 53: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

53

Resistance Fault Locate (RFL) Hookups (con’t)

Tip[A]

Ring[B]

Green

Yellow

Strap

Cross

Good Pair

965DSPRed

Black

3. Cross: Option A: Using a Separate Good Pair

Tip[A]

Ring[B]

Pair Under Test [Non-Working]

Other Pair [Non-Working]

965DSP

Green

Red

Black Tip[A]

Ring[B] - Good Conductor

Cross

Strap

Option B: Ring [B] conductors of each pair used as a GOOD pair if they are clean (no faults).

Ring[B] - Good Conductor

Tip[A]

Strap

Yellow

Page 54: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

54

Resistance Fault Locate (RFL) Hookups (con’t)

C. Cross: Option C: Using a Single Good Conductor

Tip[A]

Ring[B]

Tip[A]

Ring[B]

GreenStrap

Cross

Good conductor

965DSP

Red

Black

Pair Under Test - Non-Working

Other Pair - Non-Working

Page 55: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

55

( )

( )

Resistance Fault Locate (RFL) Hookups (con’t)

4. Battery Cross:Option A: Separate Good Pair

Tip[A]

Ring[B]

GreenStrap

Battery Cross

Good Pair965DSP

Red

Black

Pair Under Test [Non-Working]

Other Pair - Working (Unknown)

Yellow

Shield / Ground

-48VDC

CO Battery

Note: The Tip[A] conductors from each pair can be used used as the GOOD pair.

Tip[A]

Ring[B]

Tip[A]

Ring[B]

Page 56: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

56

( )

( )

Resistance Fault Locate (RFL) Hookups (con’t)

4. Battery Cross:Option B: Single Good Conductor

Tip[A]

Ring[B]

Tip[A]

Ring[B]

GreenStrap

Battery Cross

Good Conductor965DSP

Red

Black

Pair Under Test - Non-Working

Other Pair - Working (Unknown)

Shield / Ground -48VDC

CO Battery

Note: Use this option if only one GOOD conductor is available.

Page 57: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

57

RFL TIPS

The use of a

“Separate Good Pair”

is always the most accurate way to

locate any type of a resistance fault.

Page 58: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

58

“Separate Good Pair”

It can be any pair of any gauge, longer or shorter than the faulted one,

it doesn’t matter.

For short cable section lengths (1000 feet or less), the good pair can be a

reel of a CO jumper wire or a telephone jacketed wire placed above ground.

Reel of CO jumper wire

or

telephone jacketed wire

Good Pair

Faulted Pair Strap

End-1

End-2

Ground Fault

Shield/GroundNear-End Far-End

Good Pair

Page 59: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

59

“Separate Good Pair”It can be any pair of any gauge, longer or shorter than the faulted one,

it doesn’t matter.

For long cable section lengths (several thousand feet), the good pair can come

from another cable adjacent to the cable with the faulted pair.

Good Pair

Faulted Pair

Common

End-1

End-2

Near-End Far-End

Good Pair

Faulted Pair

Strap

Short

Fault

Page 60: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

60

How To Extend The “Far-End Strap” If Necessary

Reel of CO jumper wire or telephone jacketed wire or any two wires, same length

(any gauge)

Faulted Pair

Far-End Strap

End-1 End-2

Short

Near-End

Common

Good Pair [ from a distant cable ]

Strap extension

Far-End

Page 61: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

61

Fault Locating Tips

RFL (Resistance Fault Locate):

1. Always draw a diagram of the fault for better analysis.

2 . There three factors that is always involved in RFL (Resistance Fault Locating) - Gauge, Length and Temperature of the cable. Any two of the three must be known for RFL to work. The best option is to know the Gauge and Length of the section under test and the test set will compute the cable temperature. This is done during RFL Setup.

3. A pair may have some light faults in it but it can be used as a ‘Good Pair’ as long as the light fault is at least 200 times better than the magnitude of the fault in the faulted pair. Ex: If the fault on a pair is 1 kilo-ohms, a pair with a 200 kilo-ohm fault can be used as a good pair. Of course, the higher the magnitude, the better.

4. For best RFL accuracy , make a long cable section shorter by going to the middle of the section and open the pair to cut it in half. Check for the fault in one direction and then the other and then isolate the clean side. Repeat the process until the cable section becomes short enough where the following becomes practical:

a) the length of a short section can easily be measured physically with a roller tape. If gauge and section length are known, the test set will compute cable temperature.

b) With a short cable section, the use of a reel of jumper wire as a “Good Pair” placed above ground is now possible, instead of digging into the cable for a good one. Saves time. With a separate good pair and knowing the gauge and length of the section is the best and most accurate RFL option.

5. The procedure in locating a ‘Battery Cross’ is exactly the same as that for a ‘Ground’ fault.

6. In a ‘Single Pair Hookup’, the best good conductor to use is the mate of the faulted one and the next best is any good conductor from any of the adjacent pairs in the same group. Ex: If a pair has TIP(A) is faulted and RING(B) is good, RING(B) is then the best good conductor to use to shoot the fault on TIP(A).

7. If DTF (Distance-To-Fault) and DTS (Distance-To-Strap) are equal, the fault is either at the strap or beyond.

Page 62: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

62

Estimating Cable Temperatures

Aerial Cable:

1. If cable is not in direct sunlight. Add 20oF or 15oC whichever is used, to the air temperature.

2. If cable is in direct sunlight. Add 40oF or 30oC whichever is used, to the air temperature.

Buried Cable:

1. Use temperature of tap water. Let water flow out of a water faucet for several minutes and then measure the temperature using a common household thermometer.

2. In cold climates, use soil temperature at cable depth.

Page 63: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

63

Gauge (Size) Conversion Table

19------

22------

24------

26------

28------

22242628

19242628

19222628

19222428

19222426

0.4970.3100.1930.121

2.0100.6240.3890.244

3.2201.6000.6230.391

5.1802.5701.6100.628

8.2404.0902.5601.590

Example: Convert the following into 19AWG.

400 feet of 24AWG + 350 feet of 22AWG + 800 feet of 19AWG

400 x 3.220 = 1,288 feet of 19AWG

350 x 2.010 = 703 feet of 19AWG

800 x 1.000 = 800 feet of 19AWG

--------------------------------------------

Total = 2,791 feet of 19AWG

FROMGAUGE

TOGAUGE

MULTIPLYBY

Page 64: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

64

How To Determine Length of Cable In A Reel - Using RFL

Option #1:1. Create a “SHORT” at the far-end of Pair #2 and strap it to Pair #1 (Good

Pair) and connect the 965DSP clips as shown below.2. Press the RFL key and do the following:

a) Select “Separate Pair” option.b) Press the “Tab” key :

- Highlight the correct gauge (size) of the pair.- Press the ‘Select’ key and enter cable temperature (ex: 70 oF)

3. Press the ‘Enter’ key to accept options.4. Press the ‘Enter’ key to continue.5. The DTF (Distance -To-Fault) or DTS (Distance-To- Strap) measurement will

be the length of the cable.

Tip [A]

Ring [B]

Green

Yellow

Red

Black

Reel of Cable

Strap

Ring [B]

Tip [A]

Short

DynatelTM

965DSP

Pair #1 - Good

Pair #2

Page 65: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

65

Option #2:1. Press the RFL key.2. Short the pair at the far-end and connect the 965DSP test clips, as shown

below.3. Press the ‘Tab’ key to select ‘Single Pair’.4. Press the ‘Setup’ key and do the following:

a) Highlight the correct gauge (size) of the pair.c) Press the ‘Tab’ key and enter cable temperature (ex: 70 oF).

5. Press the ‘Enter’ key to accept the options.6. Press the ‘Enter’ key to continue4. The DTS (Distance-To-Strap) reading will be the length of the cable.

Ring [B]Green

Red

Black

Reel of Cable

Tip [A]

Short

DynatelTM

965DSP

How To Determine Length of Cable In A Reel - Using RFL

Page 66: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

66

Measuring Distance To A Solid Short - Using RFL

SolidSHORT(0-ohm)

Tip [A]

Ring [B]

Red

Green

Black

DynatelTM

965DSP

Note:This procedure only applies to a solid “short”, meaning (0 ohm- resistance), otherwise use the standard RFL procedure using a separate good pair or a single good conductor.

1. Connect the 965DSP test clips, as shown below.2. Press the RFL key.3. Press the ‘Tab’ key to select ‘Single Pair’.

4. Press the ‘Setup’ key and do the following:a) Highlight the correct gauge (size) of the pair.c) Press the ‘Tab’ key and enter cable temperature (ex: 70 oF).

5. Press the ‘Enter’ key to accept the options.6. Press the ‘Enter’ key to continue4. The DTS (Distance-To-Strap) reading will be the location of the solid short.

Page 67: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

67

Fault Locating Tips

OPENS Locate:

1. Make sure the ‘GREEN’clip is connected to the cable shield (ground) when locating opens.

2. Cable ‘gauge and temperature’will not affect cable capacitance.

3. For accuracy, always calibrate the test set to a good pair in the same cable as the faulted one.

4. ‘OPENS’Locate does not require a strap. Use it first when analyzing cable faults.

5. If ‘MUTUAL’measurement is 10% or more longer than Tip [A] or Ring [B], the cable shield can be open

due to a missing bond, corroded bond connections or it went open due to extreme cable temperature changes.

TDR (Time Domain Reflectometer):

In most cases, a TDR (Time Domain Reflectometer) which uses RADAR technology is a better test set to use for locating any type of OPENS [Complete Open, Partial (high-resistance) Open or Dirty Open (a combination of resistance and capacitance faults)].

But never use a TDR when you do not exactly know what type of fault/faults or line treatment devices (load coils, build-out capacitors) you are looking for.

Page 68: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

68

Metric Conversion Table

Metric Metric ApproximateUnit Length U.S. Equivalent

Metric (m) 1.0 m 39.4 inches

Millimeter (mm) .001 m .0384 inches

Micrometer (um) .000 001 m .000 0394 inches

Nanometer (nm) .000 000 001 m .000 000 0394 inches

Angstrom (A) .000 000 000 1 m .000 000 00394 inches

Page 69: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

69

Prefixes and symbols to form decimal multiples and/or submultiples.Power E Decimal Prefix Phonic Symbolof Ten Notation Equivalent

1012 E + 12 1 000 000 000 000 tera ter’a T109 E + 09 1 000 000 000 giga gi’ga G106 E + 06 1 000 000 mega meg’a M103 E + 03 1 000 kilo kil’o k102 E + 02 100 hecto hek’to h10 E + 01 10 deka dek’a da10-1 E-01 0.1 deci des’i d10-2 E-02 0.01 centi sen’ti c10-3 E-03 0.001 milli mil’I m10-6 E-06 0. 000 001 micro mi’kro u10-9 E-09 0.000 000 001 nano nan’o n10-12 E-12 0.000 000 000 001 pico pe’ko p10-15 E-15 0.000 000 000 000 001 femto fem’to f10-18 E-18 0.000 000 000 000 000 001 atto at’to a

POWERS OF TEN

Page 70: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

70

Requirement: Length of cable section under test must be known.

Procedure:

1. Connect the test set as shown in the illustration and make the “A” measurement.

2. Move the test set to the far-end and make the “B” measurement.

3. Calculate distance to the open using the formula, below:

d = (A or B) x D meters to open

C

Where:

d = Distance-To-Open

(A or B) means whichever is shorter.

D = Length of cable section under test.

C = A + B

Example:

D = 290 m

A = 110 m

B = 240 m

C = A + B = 110 + 240 = 350 m

d = A x D = 110 x 290 = 91.14 m

C 350

965DSP

965DSP

OPEN

Cable Shield

“D” measurement“A” measurement

Note: The RED and GREEN leads are used so consider the Ring [B]measurement only.

Locating OPENS by Ratio

Cable Shield

OPEN

“D” measurement“B” measurement

Measuring distance to an open using cable SHIELD as reference.

Page 71: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

71

Locating OPENS by Ratio965DSP

965DSP

OPEN Cable Shield

OPENCable ShieldCable Shield

Cable Shield

“B” measurement

“D” measurement“A” measurement

“D” measurement

Note: The RED and GREEN leads are used so consider the Ring [B] measurement only.

Measuring distance to an open shield using Earth/Soil as reference.

Red

Grn

Red

Grn

Earth/Soil

Earth/SoilGround Rod

Ground Rod

Page 72: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

72

Locating OPENS by Ratio

“B” measurement

“D” measurement

“A” measurement

“D” measurement

Note: The RED and GREEN leads are used, consider the Ring [B] measurement only.

Open

Open

965SLA

965SLA

Measuring distance to an open shield using a group of conductors as reference.

Page 73: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

73

Dynatel 965DSPSubscriber Loop Testing & Analysis

Page 74: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

74

Subscriber Loop Components

Central Office

Central Office

REG

48VDC

30VDC

78VDC Distribution Cable

48VDC Distribution Cable Telephone Set

Telephone Set

Protector

Protector

Protector

Protector

Fig. 1: Standard Telephone Circuit

Fig. 2: Telephone Circuit with REG (Range Extender with Gain).

Page 75: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

75

Why analyze a Subscriber Loop?

A: To evaluate a cable pair before it is put into service.

Generally Accepted Criteria for POTS (Plain Old Telephone Service)________________________________________________________________________________________________________________

Parameter Acceptable Marginal Unacceptable

________________________________________________________________________________________________________________

Voltage = 48 to 52VDC _________________ _______________

Loop Current = -23 mA or more -20 mA to <-23 mA < -20 mA

Circuit Loss = -8.5 dBm or less _________________ > -8.5 dBm

Power Influence = 80 dBrnC or less > -80 dBrnC to < -90 dBrnC -90 dBrnC or more

Circuit Noise = 20 dBrnC > 20 dBrnC to < 30 dBrnC -30 dBrnC or more

Balance = 60 dB > 50 dB to < 60 dB 50 dB or less

Station Ground Resistance = 25 ohms or less _________________ > 25 ohms

Slope = 7.5 dB or less _________________ > 7.5 dB

________________________________________________________________________________________________________________

Parameter Insulation Good Light Fault Heavy Fault

(Service Affected) (Out Of Service)

________________________________________________________________________________________________________________

Insulation Resistance 3.3 Meg or more > 2.8 K ohms to < 3.3 Meg 2.8 K ohms or less

Page 76: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

76

Why analyze a Subscriber Loop?

B: To identify and isolate the cause of a problem on a partially working cable pair..

Common Subscriber complaints:

1. No dial tone.

2. Continuous dial tone.

3. Signal is too weak can not hear on long distance calls.

4. Occasionally get wrong numbers.

5. Line is too noisy.

Page 77: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

77

Resistance Zones and CO Equipment

Note:

This example shows distances of the RZs based on a 22AWG (0.64mm) cable.

If the Engineers undergauge, RZ18 could start as close as 18Kft. (5,486m).

1300Ohms

1540Ohms

2000Ohms

2800Ohms

15Kft(4,572m)

37Kft(11,278m)

44Kft(13,411m)

56Kft(17,069m)

79Kft(24,079m)

Loading

required2A RE

(Range Extender)DLL + E6 Repeater

or 5A or 7A REG(Range Extender with Gain)

DLL + E6 Repeateror 5A or 7A REG

(Range Extender with Gain)

RZ13 RZ16 RZ18 RZ28CO

Page 78: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

78

TransmissionLong Route Design

2A RE

5A or 7AREG

5A or 7AREG

CO RZ13

Resistance Design

RZ16

RZ18

RZ28

Cus

tom

er L

ine

Equ

ipm

ent

Mai

n D

istr

ibut

ion

Fram

e1300 ohms

1540 ohms

2000 ohms

2800 ohms

Page 79: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

79

Load Coil Construction

Coil Sales

662 88 MH

309 79

Tip[A]

Ring[B]

Tip[A]

Ring[B]

Ring[B]Ring[B]

Tip[A] Tip[A]

Torroid (Doughnut)-shaped iron/nickel core

IN OUT

Hundreds of turns of fine magnet wire

A Load Coil is used to cancel out the effects of too much capacitance on the pair as it gets longer

so that voice frequency signals can be transmitted at longer distances (ie: 18000 to 34000 feet)

Page 80: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

80

Load Coil Schemes

Loading CutoffSystem Bandwidth Frequency Inductance Spacing

B-44 2400 Hz 6943 Hz 44 mH 3000 FtD-66 3100 Hz 4629 Hz 66 mH 4500 FtH88 4500 Hz 3471 Hz 88 mH 6000 Ft

Page 81: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

81

Resistance Design Examples

CO

CO

CO

CO

CO

14.5Kft (4,420m)

26AWG (0.41mm)

9Kft (2,743m)26AWG (0.41mm)

9Kft (2,743m)24AWG (0.51mm)

22Kft (6,706m)24AWG (0.51mm)

13Kft (3,962m)24AWG (0.51mm)

15Kft (4,572m)22AWG (0.64mm)

34Kft (10,363m)22AWG (0.64mm)

1

5

4

32

Load Coils

1 32

41 32

41 32

3Kft(914m)

6Kft(1,829m)

6Kft(1,829m)

3Kft(914m)

3Kft(914m)

6Kft(1,829m)

6Kft(1,829m)

1Kft(305m)

6Kft(1,829m)

3Kft(914m) 4Kft + 2Kft

(1,219m + 610m)

6Kft(1,829m)

6Kft(1,829m)

7Kft(2,134m)

3Kft(914m)

6Kft(1,829m)

6Kft(1,829m)

6Kft(1,829m)

6Kft(1,829m)

7Kft(2,134m)

1300 ohms14,500Ft. (4,420m)

1300 ohms18,000Ft. (5,486m)

1300 ohms22,000Ft. (6,706m)

1300 ohms34,000Ft. (10,363m)

1300 ohms28,000Ft. (8,534m)

Page 82: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

82

Build OutsCable build outs are primarily designed to make cable pairs

electrically longer when cable sections are physically too short.Build Out Configurations

1. Build Out Capacitor [BOC] - it is used when the length of cable section is more than half of the cable spacing required. (ie: H-88 coils require 6000 feet of cable spacing. If the cable section is more than 3000 feet but less then 6000 feet, a build out capacitor [BOC] must be used.

2. Build Out Lattice [BOL] - it is used when the length of the cable section is less than half of the cable spacing required. (ie: if the cable section is less than 3000 feet).

Load Coil BOC

Lake or Riverbed

6000 Ft

4750 Ft3000 Ft

CO

3000 Ft 1700 Ft

6000 Ft

Load Coil Load CoilBOL

Load Coil

CO

Physical length

Electrical length

Physical length

Electrical length

6000 Ft

6000 Ft

R

C

Lake or Riverbed

Page 83: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

83

How to compute the equivalent length of build-out capacitor and subtract it from Distance To Open measurements

Standard Tip[A] or Ring [B] to Shield/Ground Capacitances

Aircore = 0.125uf / mile (5280 feet)

Jelly-Filled = 0.140uf / mile (5280 feet)

2-Pair Drop = 0.155uf / mile (5280 feet)

5-Pair Drop = 0.150uf / mile (5280 feet)

Example:

Ring is open at 7000 feet

Aircore (Tip[A] /Ring[B] to Shield /Ground capacitances = 0.125 uf / 5280 feet

0.125uF / 5280 feet = 0.000024 uF / feet

0.000024 uF x 1000 = 0.024uF / 1000 feet

Build-Out capacitor across Tip[A] & Ring[B] = 0.0314 uF

0.0314 uF / 0.024 uF = 1.308

1.308 x 1000 feet = 1308 feet (equivalent length of build-out

capacitor)

Distance to Open on Ring [B] = 7000 feet - 1308 feet = 5692 feet

Page 84: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

84

Noise and Power Influence Measurements

QuietTermination

QuietTermination

2 uF

600 ohms

2 uF

600 ohms

Grn

Red

Blk

Grn

Red

Blk

Blk Red

Fig. 2: Power Influence is measured between Tip[A] & Ring[B] (shorted together internally) and Shield/Ground

Fig. 1:Circuit Noise (Noise Metallic) is measured between Tip[A] & Ring[B]

965DSP

965DSP

Page 85: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

85

Circuit Noise Basics

Power Line Magnetic Field

Central Office

Tip[A]

Ring[B]

2 uF

600 ohms Quiet

Termination

IT

IR

IP

Telephone Set

IP - Current flowing through the power line.

IT - Induced current on the Tip[A] conductor from the power line.

IR - Induced current into the Ring[B] conductor from the power line.

Power induction parameters:

1. Influence - depends on power utility load; therefore it varies during the day.

2. Coupling - depends on the length of exposure and separation between Telco and Power utility.

3. Susceptibility - depends on cable pair balance, shield continuity and low resistance grounds. If the pair is well-balanced, ITand IR will be equal and self-cancellation occurs and Noise = 0.

Note: 1 & 2 above, usually are beyond the control of the Telco and rarely can they do anything about them.

Page 86: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

86

Circuit Noise Basics(con’t)

Power LinePower Line

Magnetic Field

Central Office

Tip[A]

Ring[B]

2 uF

600 ohms Quiet

Termination

IT

IR

IP

Telephone Set

Shield/GroundShield

Magnetic Field

IP - Current flowing through the power line.

ISP - Induced current on the cable shield from the power line.

IT - Induced current on the Tip[A] conductor from the power line.

IR - Induced current into the Ring[B] conductor from the power line.

ITS - Induced current on the Tip[A] conductor from the cable shield.

IRS - Induced current on the Ring [B] conductor from the cable shield.

ITS

IRS

Note: 1. If the pair is well balanced, the opposing currents IT vs IR and ITS vs IRS will be equal and therefore cancel out.

2. A perfectly balanced pair can be noise-free even without a cable shield.

3. A good shield continuity and low resistance grounds can reduce Power Influence by 15dBrnC.

ISP

Page 87: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

87

Relationship between dBrnC and dBmNoise

dBrnCSignal Level

dBm0

-10

-20

-30

-40

-50

-60

-70

-80

-90

90

80

70

60

50

40

30

20

10

0

dBrnC = dB reference to noise with C-Message Weighting

dBm = dB reference to milliwatt

Note: dBm - dBm = dB

Very WeakVery Quiet

Very Noisy

Page 88: Outside Plant Telephone Cable Testing & Fault Locatingmultimedia.3m.com/mws/media/282729O/outside-plant... · Outside Plant Telephone Cable Testing & Fault Locating DynatelTM Systems

88

3M Training Center Telephone NumbersLine Assignments:

Left Side: Right Side:

1. 9-984-2983 5. 9-984-2966

2. 9-884-2974 6. 9-984-2977

3. 9-984-2966 7. 9-984-2978

4. 9-984-2988 8. 9-984-2979

3M 1020B Access Numbers - Training Room:

1. 9-984-2036 6. 9-984-2048

2. 9-984-2040 7. 9-984-2052

3. 9-984-2041 8. 9-984-2975

4. 9-984-2041 9. 9-418-1458 (10 Frequency Step Tone 1004Hz, 404Hz,

5. 9-984-2047 650Hz, 1004Hz, 1300Hz, 1704Hz, 2000Hz, 2300Hz, 2804, 3000Hz, 5000Hz) then disconnect. Duration per frequency is 5 seconds with 1 second quiet intervals. All frequencies are transmitted @ 0 dBm.)

Southwestern Bell Telephone Company

Milliwatt Tone Sources (1004 Hz.):

Jollyville C.O. 9-258-1632 Evergreen C.O. 9-474-8800 Fireside C.O. 9-345-1217

Quiet Line:

Jollyville C.O. 9-258-9827 Evergreen C.O. 9-474-8801 Fireside C.O. 9-345-1212

ANA (Automatic Number Announcer): 9-830

NYNEX Programmable Test Line (18- Frequency Tone Source) *8-518-435-2332 When initial 1004Hz tone stops, press 5 to switch source from Milliwatt to 17 frequency Step Tone - 304Hz, 404Hz, 604Hz, 804Hz, 1004Hz, 1204Hz,1404Hz, 1604Hz, 1804Hz, 2004Hz, 2204Hz, 2404Hz, 2604Hz, 2804Hz, 3004Hz, 32004Hz, 3404Hz. Press *5 to set tone levels at 0 dBm at the C.O.